TECHNICAL SITE SURVEY REPORT

SEARCHING RING NAME: Baymax2020_BrgyKamanga_Maasim_SAR


SITE ID: IMD 1032 A_________________________
SITE ADDRESS: Proper Kamanga, Maasim, Sarangani_____

RF TSSR APPROVAL SHEET

Reviewed by: Remarks

APPROVED DOCUMENT
Name __________________________
APPROVED SOLUTION
Designation______________________
REJECTED

APPROVED DOCUMENT
Name __________________________
APPROVED SOLUTION
Designation______________________
REJECTED

Name __________________________ APPROVED DOCUMENT

Designation______________________ APPROVED SOLUTION

REJECTED

Additional Remarks:
TECHNICAL SITE SURVEY REPORT

Table of Contents

NEW SITE

IMD 1032 CANDIDATE A

GENERAL INFORMATION

A1. Site Information


A2. Vicinity Map

SITE SURVEY REPORTS

 Proposed Location & Tech. Site Information


 GPS Coordinates (Proposed Site Coordinates &
Fronting Road Coordinates)
 Access Road (ROW, Brgy. Road, Main Road)
 Panoramic Pictures (0 Degree to 330 Degree)
 Coverages Objectives (Sector 1 to Sector 3)
 Nearest Tapping Point & Transformer
 Tower Lay-out (N/A)
 Ground Space & Ground Space Dimension
• Pictures (0 Degree to 330 Degree)
• Coverages Objectives (Sector 1 to Sector 3)
• Nearest Tapping Point & Transformer
• Tower Layout (N/A)
• Ground Space and Ground Space Dimension
TECHNICAL SITE SURVEY REPORT

SURVEY TEAM

RAD TEAM LIONIL D. MUA 09956591285


RAD TEAM RASHED ENGKA 09652450245
RAD TEAM SAMER LABNAN 09758084490
RAD TEAM SALAHUDIN GUIAMAD 09675072114

A1. GENERAL SITE INFORMATION

Option Name: IMD 1032 CANDIDATE A

Searching Ring Name: Baymax2020_BrgyKamanga_Maasim_SAR

Longitude: 125.056599

Latitude: 6.858958

Ground Elevation (m): +0.5m

BTS Type: outdoor

Date Surveyed: September 05, 2021

Property Name: N/A

Property Address: Proper Kamanga, Maasim, Sarangani

Area Type: Agricultural

Wind Zone: v = 300 kph


TECHNICAL SITE SURVEY REPORT

A2. VICINITY MAP


DISTANCE FROM NOMINAL POINT – 230m

IMD 1032 NP

230m
IMD 1011 NP
IMD 1032 A 73m
IMD 1011 A

DISTANCE FROM SHORELINE


- 315m

MAIN ROAD

RIGHT OF WAY AVAILABLE LOT


Owned by the Lessor Owned by the Lessor

Right of Way
(5m wide)
PROPOSEDRIGHT
SITE OF WAY
IMD 1032 A (5m wide)
Elev.: +0.5m
Owned by Lessor

TECHNICAL SITE SURVEY REPORT

B. SITE SURVEY REPORTS

A. Distance from shoreline: ____________315_m____________

B. Type and Height of Structure:

N/A
 30
N/A N/A

C. Type of Attachment /Anchorage

 15 20

C1. Topographic Condition of the Site


C2. If the site is Rolling or Mountains, does it require?


C3. Is the site located in one of the following conditions?
TECHNICAL SITE SURVEY REPORT

D. Type of Radio Room


N/A N/A

N/A N/A

N/A N/A N/A

E. Accessibility to Site

Width= 9 Concrete
Width= 6 Concrete
Width= 5 Dirt road

Width= 5 Dirt road



F. Commercial Power availability

Greenfield Site:
Secondary Power Line
Length of tapping point from (Service Entrance to existing electrical pole) ________20_______m
(From existing pole to existing transformer) _______ 0________m
Primary Power Line
Distance of primary line (from existing transformer to primary line) _______N/A________m
Estimated no. of poles at ___30_____m pole to pole _______0______pc
Commercial AC to power supplied by Electric Company/Cooperative ________N/A_________
TECHNICAL SITE SURVEY REPORT

Rooftop Sites:

Approval of lessor of the proposed location of meter of submeter YES


Check the availability of required loads with building owner N/A
Avail temporary power supply during constructions and during On-air site of Site until permanent power is available
(to provide conceptual drawing of AC Commercial Tapping point) (To apply for tempo Power)

Temporary Power Source:

 

G. Earthing System (for Rooftop Sites)

 N/A

Negotiate with Building owner the proposed location where to drive ground rod and test pit. N/A
Discuss with the Building owner the possible grounding and cable route and get approval N/A

N/A N/A

Discuss with building owner the possible earthing cable route and get approval N/A
Check the tapping point and the terminal lug to be used N/A
Check if there are obstructions along the proposed cable route N/A

H. Drainage System (for greenfield only)

N/A
N/A

Provide possible location on conceptual drawing


I. Obstruction during erection


Discuss with building owner the possible earthing cable route and get approval (N/A)
Check the tapping point and the terminal lug to be used (N/A)
F. Commercial
Check Power
if there are availability
obstructions along the proposed cable route (No Obstruction)
TECHNICAL SITE SURVEY REPORT

J. Flood History (as acquired by lessor and/or neighbors)

_there is no flood history in the area_ (with respect to road/ right of way)

K. Lot elevation from fronting road (approx.) (+) ____0.5__ m / (-) ________ m


L. Soil condition Report (to be secured from engineering office, if not available subsoil exploration
to be conducted as may require by client)

M. Usage of proposed Location

N. Existing Ordinance




TECHNICAL SITE SURVEY REPORT
O. Peace and Order Situation, History: _The area are generally peaceful and orderly.
______________________________________________________________________________
TECHNICAL SITE SURVEY REPORT
_______________________________________________________________________________

P. Mode
SITE of Transportation going to proposed site, in detail (starting from main road/town)
LAYOUT
The main road and right of way are wide enough for any vehicle to enter the proposed site. ____
PROPOSED SITE
IMD 1032 A
Q. Variation Works: _Removal of grasses and loose topsoil._____ (15m x 20m)
Elev.: +0.5m
_______________________________________________________________________________

R. Remarks and Narrative Report: _The proposed site is located near the main road and it is

an open area, so there is no problem with the access.

H
E
R
E

R
O
W PROPOSED ENTRANCE

PROPOSED SITE COORDINATE: 5.858958,


125.056599
RIGHT OF WAY: OWNED BY THE LESSOR
IMD 1032 A
ROW - 5m wide
Owned by the Lessor

TECHNICAL SITE SURVEY REPORT

PROPOSED LOCATION

H
E
R
E
ROAD ACCESS – BARANGAY ROAD (5m wide)

SITE LOCATION IS INFRONTING MAIN ROAD – 15m AWAY

THIS WAY

TECHNICAL SITE SURVEY REPORT


PANORAMIC PICTURES (0˚ - 90˚)


30˚

60˚ 90˚

TECHNICAL SITE SURVEY REPORT


PANORAMIC PICTURES (120˚ - 210˚)

120˚ 150˚

180˚ 210˚

TECHNICAL SITE SURVEY REPORT


PANORAMIC PICTURES (240 - 330˚)

270˚
240˚ TECHNICAL SITE SURVEY REPORT

COVERAGE OBJECTIVES

SECTOR 1 - 280˚

300˚
330˚
SECTOR 2 - 130˚
TECHNICAL SITE SURVEY REPORT

COVERAGE OBJECTIVES

SECTOR 3 - 280˚
TECHNICAL SITE SURVEY REPORT

PHOTO OF NEAREST TAPPING POINT

Nearest tapping point


IMD 1032 A
CABLE ROUTING FROM POWER SOURCE

PRIMARY LINE

20m

IMD 1032 A

TECHNICAL SITE SURVEY REPORT


GROUND SPACE DIMENSION

20m
AREA = 300m²