You are on page 1of 7

TECHNICAL SITE SURVEY REPORT

(TSSR)

SITE ID :__ MW0697_______

SITE NAME :__LIKOMA____

Jun. 2014
3G SITE SURVEY SHEET

Site Name LIKOMA No MW0697 Date 15-08-2014


Location Town Likoma
Site Type Airtel
Site Type Greenfield Rooftop Existing Structure Indoor Outdoor VDM Build Cell C Upgrade
GPS Position Measured During Survey Latitude S12.074627 Longitude E34.721964

ACCESS INFORMATION
Contact Person CHEKANI Number 0999959869
Substitute Number
Access Days 15-08-2014 Access road Good Bad Very bad
Notes

TOWER N/A Existing New Tower Height 70 m


Antenna Height (2G) 67m
Antenna Azimuth (2G) A Sector 0 B Sector 120 C Sector 240
Microwave Height 44m
Tower Type Monopole Concrete Mono Pole Lattice Stub Enviro Spec Signboard Other
Type of Loading Required Urban Rural Environ Strategic Rooftop/Stub
Terrain Category on the hill Tower Category .
Aviation Lights Motivated Metro Rural Paint Yes No Colour Red and White
Notes

EQUIPMENT SHELTER
N/A New Existing
Shelter Type N/A Isotherm Special
Equipment Space Available Unavailable
Cable Tray Space Available Unavailable
Size 2.4x2.8 2.4x2.4 2.0x2.0 Other 3*3
Feeder Entry Plate Existing New
Notes

OUTDOOR FOUNDATION
N/A New Existing Renovate
Concret base 3 m by 3 m
Notes

1
RF&RRU INSTALLATION
A Sector Jump cable size 1/2 Jump cable length 2m Qty 2
B Sector Jump cable size 1/2 Jump cable length 2m Qty 2
C Sector Jump cable size 1/2 Jump cable length 2m Qty 2
A Sector RRU mounting height 64m Fiber &DC Cable length 73m Qty 2
B Sector RRU mounting height 64m Fiber &DC Cable length 73m Qty 2
C Sector RRU mounting height 64m Fiber &DC Cable length 73m Qty 2
Ant Information
Proposal 3G Antenna Height 64m
Available free space range_________(15-60)and(63-67)m____________________
Proposal Antenna Azimuth A Sector 0 B Sector 120 C Sector 240
Existing 2G Antenna type V-pole X-pole H-Frame
H-Frame New Existing
Antenna Pole Yes No Qty 3 Length 2 m
Transmission Type Tie Cable Cable Microwave Satelite
Trunking (75x50) N/A PVC Steel Length 5m Paint Yes No Colour .
Antenna Mount Wall Mount Floor Mount Pole Mount
Access Workman Cage Platform Scaffolding Cherry Ricker Abseiling
Notes

DC INFORMATION
Existing Rec. Model Existing Capacity 3.6KVA
Output Voltage +24V -48V
Existing circuit Breaker Detail:
Breaker Available Unavailable Capacity C32
Note:

First to shut down _____C100*2+C20*6________________________________


Second to shut down _____C32+C16*4+C10____________________________________
Battery:
Battery Supplier/Type Existing Capacity ? Group 2
Notes the battery is sealed.

2
SURVEY PHOTOS
The photo for Existing Tower

The position for 3G RRU& ANT.

The photo for site environment

3
The photo
for Site
location.

4
The photo
for existing
room
location or
outside
equipments

The photo
for Existing
DC.

5
The photo
for the space
for New
Equipment.

The photo
for access
road

You might also like