The figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see
reverse side of this sheet). The Y-axis is indicated as sensor resistance ratio (Rs/Ro) which is defined as follows:
Rs = Sensor resistance in displayed gases at various concentrations
Ro = Sensor resistance in 5000ppm of methane
100 100
10 10 Air
Air
Ethanol
Iso-butane
0.1 0.1
100 1000 10000 100000 100 1000 10000 100000
Gas concentration (ppm) Gas concentration (ppm)
IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY
RECOMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET
GASES ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS
NOT BEEN SPECIFICALLY TESTED BY FIGARO.
Basic Measuring Circuit:
The sensor requires two voltage A common power supply circuit can
inputs: heater voltage (VH) and circuit be used for both VC and VH to fulfill the
voltage (VC). The heater voltage (VH) sensor's electrical requirements. The
is applied to the integrated heater in value of the load resistor (RL) should be
order to maintain the sensing element chosen to optimize the alarm threshold
at a specific temperature which is value, keeping power dissipation (PS)
optimal for sensing. Circuit voltage of the semiconductor below a limit of
(VC) is applied to allow measurement of 15mW. Power dissipation (PS) will be
voltage VOUT(VRL) across a load resistor highest when the value of Rs is equal
(RL) which is connected in series with to RL on exposure to gas.
the sensor.
Methane in air
Test gas conditions 3.6±0.1 3.6±0.1
at 20±2˚C, 65±5%RH
u/m:mm
Pin connection:
1: Heater
2: Sensor electrode (-)
3: Sensor electrode (+)
The value of power dissipation (PS) can Sensor resistance (Rs) is calculated with 4: Heater
be calculated by utilizing the following a measured value of VOUT( VRL) by using
formula: the following formula:
2 V
(V
PS = C - VRL) RS = ( C - 1) x RL
VRL FIGARO USA, INC.
RS
121 S. Wilke Rd. Suite 300
Arlington Heights, Illinois 60005
For information on warranty, please refer to Standard Terms and Conditions of Sale of
Figaro USA Inc. All sensor characteristics shown in this brochure represent typical Phone: (847)-832-1701
characteristics. Actual characteristics vary from sensor to sensor. The only characteristics Fax: (847)-832-1705
warranted are those in the Specification table above. email: figarousa@figarosensor.com
REV: 10/13