Professional Documents
Culture Documents
1 s2.0 S0306261911001760 Main
1 s2.0 S0306261911001760 Main
Applied Energy
journal homepage: www.elsevier.com/locate/apenergy
Application of intensified heat transfer for the retrofit of heat exchanger network
Yufei Wang a,1, Ming Pan a,1, Igor Bulatov a, Robin Smith a, Jin-Kuk Kim b,⇑
a
Centre for Process Integration, School of Chemical Engineering and Analytical Science, The University of Manchester, Manchester, M13 9PL, UK
b
Department of Chemical Engineering, Hanyang University, 17, Haengdang-dong, Seongdong-gu, Seoul, Republic of Korea
a r t i c l e i n f o a b s t r a c t
Article history: A number of design methods have been proposed for the retrofit of heat exchanger networks (HEN)
Received 5 August 2010 during the last three decades. Although considerable potential for energy savings can be identified from
Received in revised form 1 March 2011 conventional retrofit approaches, the proposed solutions have rarely been adopted in practice, due to sig-
Accepted 17 March 2011
nificant topology modifications required and resulting engineering complexities during implementation.
Available online 22 April 2011
The intensification of heat transfer for conventional shell-and-tube heat exchangers can eliminate the dif-
ficulties of implementing retrofit in HEN which are commonly restricted by topology, safety and mainte-
Keywords:
nance constraints, and includes high capital costs for replacing equipment and pipelines. This paper
Heat exchanger network (HEN)
Retrofit
presents a novel design approach to solve HEN retrofit problems based on heat transfer enhancement.
Heat transfer enhancement (HTE) A mathematical model has been developed to evaluate shell-and-tube heat exchanger performances,
Heat exchanger model with which heat-transfer coefficients and pressure drops for both fluids in tube and shell sides are
Heuristics obtained. The developed models have been compared with the Bell-Delaware, simplified Tinker and
Wills–Johnston methods and tested with the HTRIÒ and HEXTRANÒ software packages. This demon-
strates that the new model is much simpler but can give reliable results in most cases. For the debottle-
necking of HEN, four heuristic rules are proposed to identify the most appropriate heat exchangers
requiring heat transfer enhancements in the HEN. The application of this new design approach allows
a significant improvement in energy recovery without fundamental structural modifications to the
network.
Ó 2011 Elsevier Ltd. All rights reserved.
0306-2619/$ - see front matter Ó 2011 Elsevier Ltd. All rights reserved.
doi:10.1016/j.apenergy.2011.03.019
46 Y. Wang et al. / Applied Energy 89 (2012) 45–59
Nomenclature
techniques in the heat recovery systems was discussed without ture of the cold stream can be higher, due to geometry-characteris-
providing systematic procedures for implementing the enhance- tics of exchangers. When multiple tube passes are used for ST
ment in the retrofitting of heat recovery network. Zhu et al. [2] pre- exchangers, the flow arrangement combines the counter and co-cur-
sented a methodology for applying HTE in retrofit, based on the rent flows, and consequently, the feasibility of heat transfer is limited
network pinch approach. The proposed procedure aims to find by those flow patterns in the exchangers. To overcome this problem,
out which exchanger should be enhanced and the augmentation additional constraints were specified for ST exchangers in their mod-
level of enhancement. However, the enhancement devices were el. Ponce-Ortega et al. [7] presented a new MINLP model for HEN syn-
used only for additional area identified from the network pinch thesis with consideration of phase change in heat exchangers.
method, without using the full benefits of enhanced heat transfer. Although benefits of mathematical programming have been
Asante and Zhu [8] developed a network pinch method for retrofit exploited, the application of these methods was limited when the
scenarios and Smith et al. [3] further improved the method by con- problem size is large and rigorous exchanger models are to be used.
sidering multi-segmented stream data. They combined structural Although various studies and methodologies have been pro-
modifications and cost optimisation in a single step to achieve posed for HEN retrofit, most work assumes constant heat-transfer
cost-effective design. coefficients and neglects fluid pressure drops, which is not suitable
It is common to use mathematical programming methods for for practical application and retrofit, because heat-transfer coeffi-
HEN retrofit. Yee and Grossmann [5] presented a systematic proce- cients and fluid pressure drops vary with design. Furthermore, very
dure for the retrofit design of HEN. They proposed a design method expensive costs associated modifications and implementation, are
using superstructure that includes all the possible structural scenar- not fully considered in most existing methods, and typical indus-
ios, and formulated an optimisation framework as mixed-integer trial problems are usually too big to be effectively solved with
nonlinear programming (MINLP) model. Sorsak and Kravanja [6] the available HEN synthesis methods.
proposed an MINLP optimisation model for HEN retrofit, in which To avoid the aforementioned disadvantages, this paper proposes a
the selection of different exchanger types, such as, double pipe novel approach for HEN retrofit through heat transfer enhancement.
exchangers (DP), shell-and-tube exchangers (ST), and plate and In our approach, a detailed model for heat exchangers has been devel-
frame exchangers (PF), was made simultaneously. Since their ex- oped for calculating heat-transfer coefficients and pressure drops in
tended model considered different types of exchangers, feasibility heat exchangers, and then five heuristic rules based on expertise
of heat transfer throughout the HEN is strongly dependent on the and knowledge in the process engineering communities have been
choice of exchanger types, which limits the extent of heat recovery. proposed to identify suitable heat exchangers for employing
For example, in counter-flow heat exchangers, the outlet tempera- enhanced heat transfer techniques in the HEN. Finally, the retrofit
Y. Wang et al. / Applied Energy 89 (2012) 45–59 47
problems can be dealt without involving complex calculations. In of HEN in which phase change can occur in the exchanger,
addition, the characteristics of real-world engineering problems im- as long as the performance of the exchanger can be evalu-
posed on the retrofit of HEN are considered, such as variable heat- ated through mathematical modelling or performance data.
transfer coefficients, pressure drop constraints, varying stream ther- (2) The type of shell-and-tube heat exchanger considered is AES,
mal properties and detailed geometry of heat exchangers. New de- namely, front head type channel and removable cover (A),
sign methodology aims to maximise energy saving without shell type is one pass shell (E), and rear head type is floating
topology modifications, for example, pipeline repiping, match rese- heat with backing device (S).
quencing and new exchanger installing, and hence, no structural op- (3) The baffle type is single segmental.
tions other than intensified heat transfer is considered. (4) Baffle cut varies 20–50%.
The paper will first make a problem statement for rigorous heat (5) Tube layout angle is 90°.
exchanger modelling, which is then followed by the descriptions of (6) Tube insert, hiTRANÒ (produced by Cal Gavin Ltd.), is used
a new model for shell-and-tube exchangers, and heuristic rules for for heat transfer enhancement. Heat-transfer coefficient
HEN retrofit. Afterwards, the detailed heat exchanger model pro- and pressure drop of hiTRANÒ can be obtained from soft-
posed in this paper will be validated, and then a case study of a ware hiTRAN.SPÒ (supported by Cal Gavin Ltd.) [10].
large-scale HEN retrofit problem is presented and solved with
the proposed approach. To improve the heat exchanger model, heat exchange other than
liquid phases (e.g., condensation, vapour-to-liquid transfer) will be
considered in future work. So far, the most common and widely-
2. Problem statement used methods, including the Bell-Delaware method, simplified Tin-
ker method and Wills Johnsoton method only address liquid phase
Since shell-and-tube heat exchangers are the most widely used heat transfer. Moreover, although one type of heat transfer
in process industries, it is assumed that heat recovery in the paper enhancement and its enhancement on tube-side is only considered
is based on heat transfer through shell-and-tube exchanger type. for HEN retrofit in this paper, the proposed design approach is gen-
The heat-transfer coefficient and pressure drop of each individual eric enough to be used for accommodating other enhancement
heat exchanger in the network are calculated by the new model methods (e.g., twisted-tap tube inserts, coiled wire tube inserts,
proposed in this paper. Before evaluation of detailed performance helical baffles, etc.) as well as other retrofit options, including heat
of the heat exchanger, the overall configuration of the HEN must transfer enhancements with both tube and shell sides and suitable
be known, and thus, the problem to be addressed in this paper is topology modifications based on the network pinch approach.
based on the following information and assumptions.
It is assumed that the following information is given:
3. Modelling of shell-and-tube heat exchanger
(1) Matches between hot streams and cold streams.
(2) The current use of utilities for heating and cooling in the For predicting heat exchanger performance, it is necessary to
existing HEN. calculate the overall heat-transfer coefficient, and pressure drop
(3) Stream data (i.e., flowrates, inlet temperature and outlet for both fluids in tube and shell side. Understanding of fluid behav-
temperature, density, specific heat capacity, viscosity, ther- iour in the tube side is relatively straightforward, and well-known
mal conductivity and fouling coefficient). correlations, such as Colburn correlation [11], Dittus–Boelter corre-
(4) Tube-side geometry of heat exchangers (i.e., tube length, lation [11] and plain tube pressure drop method [12] are suffi-
tube inner diameter, number of tubes, number of tube ciently accurate for tube-side calculations. The methods
passes, tube wall conductivity and nozzle inner diameters commonly used for shell-side calculation include the Bell-Delaware
of tube-side). method [13], Developed Delaware method [14], Chart method [15],
(5) Shell-side geometry of heat exchangers (i.e., tube outer simple Delaware method [16], simplified Tinker method [17] and
diameter, tube pitch, tube layout angle, shell inner diameter, Wills–Johnston method [18]. However, those available methods
number of shell passes, baffle spacing, baffle cut, shell-bun- for shell-side often result in significantly different heat-transfer
dle clearance and nozzle inner diameters of shell-side). coefficients and pressure drops, compared with commercial soft-
ware (e.g., HTRIÒ), which have been accepted and widely used in
The design methodology for retrofitting HEN is required: the process industries. Therefore, this study has been carried out
to respond to this fundamental need for developing more reliable
(1) To identify suitable heat exchangers for heat transfer models for estimating performance of shell-and-tube exchangers.
enhancement. In the new model, heat-transfer coefficients and pressure drops
(2) To calculate heat-transfer coefficients of heat exchangers of tube-side are calculated firstly, and then improved models of the
before and after enhancement. Chart method [15] and simple Delaware method [16] are used for
(3) To calculate pressure drops of tube and shell sides for heat shell-side calculations, the overall heat-transfer coefficient, loga-
exchangers before and after enhancement. rithmic mean temperature difference (LMTD), LMTD correction fac-
(4) To minimise the use of utilities for heating and cooling in the tor (FT), and overall heat transfer area are addressed in sequence.
retrofitted HEN. Fig. 1 describes the geometric details of shell-and-tube heat
exchangers and their schematic diagram which explain definition
The aim with our design approach is to utilise heat transfer of various parameters and specifications required in the calcula-
enhancements and consequently to reduce the energy consump- tions of heat transfer and pressure drops.
tions of HEN in which no topology modification is needed. To de-
rive the proposed approach for HEN retrofit, the following 3.1. Tube-side heat transfer coefficient
assumptions and strategies are made:
To calculate tube-side heat transfer coefficient, the velocity (vi),
(1) Heat exchange between streams in the liquid phase is only Reynolds number (Rei), and Prandtl number (Pri) of the tube side
used for heat exchanger model. But it does not restrict the have to be obtained first, as shown in Eqs. (1)–(3), where Di is tube
proposed heuristic rules to be implemented for the retrofit inner diameter; m i is the mass flow-rate of tube-side fluid; np and
48 Y. Wang et al. / Applied Energy 89 (2012) 45–59
Ds Lsb
D0
Tube
Tube pass
1
2
Dni Dno A’ Bin Di
……
Baffle
nt = 47 np
Tube-side Shell-side
Outlet Outlet
(a) shell-and-tube heat exchanger (b) A-A’ (tube bundle) (c) A-A’ (baffle cut & tube pass)
L: tube length, B: baffle spacing, Bin: inlet baffle spacing, Bout: outlet baffle spacing, nb: baffle number, Dno: shell-side nozzle diameter,
Dni: tube-side nozzle diameter, PT: tube pitch, Ds: shell diameter, Di: tube inner diameter, D0: tube outer diameter, Lsb: Shell-bundle clearance,
nt: tube number, Bc: baffle cut, np: tube pass
nt are the number of tube passes and tubes, respectively. For tube- np fi Lqi v 2i
DPfi ¼ ð10Þ
side fluid properties, specific heat capacity (Cpi), viscosity (li), fluid 2g c Di
density (qi), and thermal conductivity (ki) are evaluated at average
where gc is unit conversion factor which is equal to 1.0 kg m/(N s2).
bulk fluid temperature, and these values are assumed to be known.
Eqs. (11)–(13) presents the pressure drop related to the tube
i ðnp =nt Þ
m entrance, exit and return losses (DPr) [12]. ar is the number of
vi ¼ ð1Þ
qi ðpD2i =4Þ velocity heads allocated for minor losses.
ar ¼ 2np 1:5 for turbulent flow ð11Þ
Rei ¼ Di v i qi =li ð2Þ
ar ¼ 3:25np 1:5 for laminar flow ð12Þ
Pri ¼ C Pi li =ki ð3Þ
Eq. (4) shows the correlation of tube-side Nusselt number (Nui) 0:5ar qi v 2i
DP r ¼ ð13Þ
based the Dittus–Boelter correlation [11], in which some of original gc
parameters for cooling had been updated. To estimate the pressure drop in nozzles (DPni), inlet and outlet
( nozzles should be considered separately, as shown in Eqs. (14)–
0:024Re0:8 0:4
i Pri for heating (21) [12].
Nui ¼ Rei 104 ð4Þ
0:023Re0:8 0:4
i Pri for cooling i
m
v ni;inlet ¼ ð14Þ
qi ðpD2ni;inlet =4Þ
Nui ¼ 0:116ðRe2=3
i 125ÞPr1=3
i ½1 þ ðDi =LÞ
2=3
2100 < Rei
Dni;inlet v ni;inlet qi
< 104 ð5Þ Reni;inlet ¼ ð15Þ
li
Nui ¼ 1:86½Rei Pri ðDi =LÞ1=3 Rei 2100 ð6Þ
0:375NS qi v 2ni;inlet
where L is tube length. DPni;inlet ¼ for turbulent flow ð16Þ
gc
Then, tube-side heat transfer coefficient (hi) can be calculated:
hi ¼ ðki =Di Þ Nui ð7Þ 0:75N S qi v 2ni;inlet
DPni;inlet ¼ for laminar flow ð17Þ
gc
3.2. Tube-side pressure drop where vni,inlet is the velocity of inlet nozzle in tube side, Dni,inlet is the
inner diameter of inlet nozzle in tube side, NS is the number of shell
Tube-side pressure drop is contributed to by three major ele- passes, and DPni,inlet is the pressure drop of inlet nozzle in tube side.
ments, pressure drop due to fluid friction in straight sections of mi
tube (DPfi), pressure drop due to tube entrance, exit and return
v ni;outlet ¼ 2
ð18Þ
q i ðp Dni;outlet =4Þ
losses (DPr), and pressure drop in nozzles (DPni).
The pressure drop due to friction loss (DPfi) is based on Darcy Dni;outlet v ni;outlet qi
friction factor (fi) [12]. Reni;outlet ¼ ð19Þ
li
fi ¼ 0:4137Re0:2585
i Rei 3000 ð8Þ
0:375NS qi v 2ni;outlet
DPni;outlet ¼ for turbulent flow ð20Þ
fi ¼ 64=Rei Rei < 3000 ð9Þ gc
Y. Wang et al. / Applied Energy 89 (2012) 45–59 49
where function ev endXe returns the largest even number not larger f2 ¼ ð0:0016 þ 2:2835 103 Ds ÞRe0:157
0 ; Ds ¼ 0:59 if Ds
than X, Lsb is the diameter clearance between shell and tube bundle, 0:59 m ð42Þ
Dotl is bundle outer diameter, PT is tube pitch, and B is central baffle
spacing. The pressure drop in straight section of shell with 20% baffle cut
The relationship of factors Fs, Fz and baffle cut (Bc) is given in the (DPf0,20%Bc) can be determined in Eqs. (43) and (44).
chart proposed by Ayub [15], in which Fs is the function of Fz and Bc. DPf 0;20%Bc ¼ ðnb 1ÞDPfb þ Rs DP fb ð43Þ
The correlations of Fs, Bc and Fz are formulated as:
where Rs is the correction factor for unequal baffle spacing, B is cen- initial estimated value, and then this will be iterated and updated
tral baffle spacing, Bin and Bout are inlet and outlet baffle spacing, accordingly, and the outlet temperature of tube side (Ti,outlet) can
respectively. be calculated based on energy balances.
To consider the pressure drop in straight section under different
m i C pi ðT i;outlet T i;inlet Þ
0 C p0 ðT 0;outlet T 0;inlet Þ ¼ m ð59Þ
baffle cuts (DPf0), new correlations are proposed in Eqs. (45)–(47).
where T0,inlet is the inlet temperature of shell side, and Ti,inlet is the
DPf 0 ¼ DPf 0;20%Bc ðBc =20%Þ0:26765 ; 20% < Bc 30% ð45Þ
inlet temperature of tube side.
LMTD is the mean temperature difference between the two fluid
DPf 0 ¼ DPf 0;20%Bc ðBc =20%Þ0:36106 ; 30% Bc < 40% ð46Þ streams, which is shown in Eq. (60).2
DPf 0 ¼ DPf 0;20%Bc ðBc =20%Þ0:58171 ; 40% Bc 50% ð47Þ jT 0;inlet T i;outlet j jT 0;outlet T i;inlet j
LMTD ¼ jT T i;outlet j
ð60Þ
ln jT 0;inlet
0;outlet T i;inlet j
The pressure drop in shell-side nozzles can be determined in the
same correlations as calculating the pressure drops in tube-side
nozzles. In multi-tube-pass heat exchangers, the flow pattern includes both
counter and co-current flows and, therefore, the mean temperature
0
m
v n0;inlet ¼ ð48Þ difference is not equal to the logarithmic mean when tube passes
q0 ðpD2n0;inlet =4Þ are more than one, and the correction factor of LMTD (FT) is used
[12].
Dn0;inlet v n0;inlet q0
Ren0;inlet ¼ ð49Þ
l0 T 0;inlet T 0;outlet
R¼ ð61Þ
T i;outlet T i;inlet
0:375NS q0 v 2n0;inlet
DPn0;inlet ¼ for turbulent flow ð50Þ
gc T i;outlet T i;inlet
P¼ ð62Þ
T 0;inlet T i;inlet
0:75NS q0 v 2
n0;inlet
DPn0;inlet ¼ for laminar flow ð51Þ For R–1:
gc
1=Ns
1 RP
where vn0,inlet is the velocity of inlet nozzle in the shell side, Dn0,inlet a¼ ð63Þ
is the inner diameter of inlet nozzle in shell side, NS is the number of 1P
shell passes, and DPn0,inlet is the pressure drop of inlet nozzle in shell
side. a1
S¼ ð64Þ
aR
0
m
v n0;outlet ¼ ð52Þ pffiffiffiffiffiffiffiffiffiffiffiffiffiffi
230
200
300
100
C1 N:14 3 N:5 5
80
25
There are four utility paths: exchangers 6, 1 and 8; exchangers 6, 2 and 7; exchangers 6, 4 and 10; exchangers 6, 5 and 9.
Fig. 2. A heat exchanger network.
5
ciency for all these options is not straightforward. Moreover, safety
4
and operability play an important role in the decision for retrofit-
3
temperature( )
ting. These factors are qualitative in nature, and although they can-
2
not be expressed explicitly, they must be traded off against other
1
design requirements. To solve complex and large-scale problems,
0
solution strategies for solving optimisation problems can benefit
-20 -10 -1 0 10 20 30 40 50 by considering heuristic rules [19–21]. In this section, several heu-
-2 ristic rules are proposed for HEN retrofit to identify the exchangers
-3 Ex. 2 to be enhanced.
-4
Change in UA 4.1. Rule 1: searching for exchangers in utility path
1
Candidates are those exchangers which may increase heat
0.8
Change of hot utility inlet
0.4
ity path can the consumption of utility be reduced by increasing
0.2
the duty of the exchangers without changing the target tempera-
0
ture of streams [22–24]. If it is desired to retrofit the network with-
-10 -5 -0.2 0 5 10 15 20 25
out any topology modifications, changing the duty of exchangers
-0.4
through utility paths is the only way. So, first of all, the candidates
-0.6
should be on utility path. Fig. 2 is used to illustrate the procedure
-0.8
Ex.3 of searching exchangers in utility paths. As shown in Fig. 2, every
-1
exchanger is on a utility path. After checking utility paths, there
-1.2
are, in general, many candidate exchangers to be further examined.
Change in UA
The exchangers on the same stream with a utility exchanger can
Fig. 3. Sensitivity graphs of exchangers 2 and 3. affect the duty of the utility exchanger directly. And these
exchangers should be selected. For example, if a reduction of hot
of shell side until the values of A and A0 are converged, which is utility is required, exchangers 1, 2, 4 and 5 should be selected to
usually converged after a few iterations. the next step analysis, because all of these exchangers are involved
to raise the temperature of the cold stream (C2).
4. Heuristic rules for HEN retrofit with HTE 4.2. Rule 2: sensitivity analysis
In this paper, HEN retrofit problems consider aspects of the After heat exchangers are selected with Rule 1, sensitivity tables
reduction in the use of utilities, number of heat exchangers to be presented by Kotjabasakis and Linnhoff [25] are used to quantify
enhanced, enhancement details of each heat exchanger and the impact of heat transfer intensity on utility consumption of
52 Y. Wang et al. / Applied Energy 89 (2012) 45–59
Yes
Any other good candidates?
No
No
Result
Table 1
Method details of the compared models.
Table 2
Stream data and geometry of heat exchangers: examples 1–5.
the HEN. Sensitivity tables are based on a simple heat transfer where DQmax is the maximum heat recovery, DTinitial is the initial
equation,2 in which only stream data and network structure are temperature difference between the inlet of high CP stream and
needed. the outlet of low CP stream, and CPmin is CP value of the stream that
Assume that the inlet temperature of cold utility in a HEN is the has lower CP in the exchanger.
response parameter, the change of temperatures for utility From Eq. (70), energy saving depends on CPmin and DTinitial. If a
exchangers related to utility paths will be known, when the UA va- heat exchanger on utility path is enhanced, then for the exchanges
lue (heat-transfer coefficient, U, multiplied by area, A) of candidate between the enhanced one and utility exchanger, the heat transfer
exchangers is changed. The best candidate exchanger can be found is reduced, due to small heat transfer driving force. In other words,
if its response parameter has a high sensitivity. As shown in Fig. 3, the exchanger with large CPmin and DTinitial, and close to utility ex-
exchanger 2 is a good candidate, since with 25% increment of UA changer can be a high sensitivity heat exchanger.
value, the inlet temperature to cold utility increases by almost The objective of this methodology is to find the best candidate.
4 °C. By contrast, exchanger 3 is not a good candidate because, with Very good candidates can be easily identified. Although a system-
25% increment of UA value, the inlet temperature of utility in- atic way to distinguish which exchangers are good for enhance-
creases only slightly. Sensitivity analysis is the key basis of the pro- ment has been proposed, the proposed method is based on
posed work, which can help to indentify the exchangers with large heuristics, not deterministic approach, which requires users’
energy saving potential. judgement and decision. Application of optimisation techniques
To explain why high sensitivity exchangers can be good candi- would be possible for the improvement.
dates, Fig. 4 is used to show the maximum heat recovery in a heat
exchanger, where the red line indicates the hot stream, and the 4.3. Rule 3: checking pinching match
blue line indicates the cold stream. In the figure, the slope of line
is the reciprocal value of CP (heat-flow capacity which is the prod- From the network concept presented by Asante and Zhu [8], it
uct of heat capacity and flow-rate) for each stream, and the equa- can be noted that pinching match is the bottleneck of heat recovery
tion of maximum heat recovery in an exchanger is given as: network. A pinching match is defined as an exchanger match
DQ max ¼ DT initial CP min ð70Þ where the temperature approach between hot and cold streams
unavoidably tends towards a limiting value as the heat recovery
in the HEN is increased. Normally, the pinching match will have
a very small heat transfer temperature difference. When the heat
2
Q = U A DTLM, where Q is the overall heat transfer load, U is overall heat transfer recovery of the network is further to be increased, heat transfer
coefficient, A is heat exchanger area, DTLM is the log-mean temperature difference. temperature difference for the pinching match will go towards
54 Y. Wang et al. / Applied Energy 89 (2012) 45–59
Table 3
Stream data and geometry of heat exchangers: Examples 6–10.
Table 4
Modelling results: examples 1–3.
Tube-side Shell-side Tube-side Shell-side Tube-side heat transfer Shell-side heat transfer Overall heat transfer
temperature temperature pressure drop pressure drop coefficient (W/(m2 K)) coefficient (W/(m2 K)) coefficient U (W/(m2 K))
(°C) (°C) (kPa) (kPa)
Example
1
M1 38 69 200 115 70.0 7.1 885.0 901.1 286.3
M2 38 72 200 105 70.0 10.5 1207.1 1400.7 365.5
M3 38 73 200 104 70.0 8.9 1207.1 1583.2 376.8
New 38 73 200 104 70.0 12.1 1207.1 1508.9 372.5
Model
HTRI 38 72 200 105 71.2 12.5 1299.3 1473.5 380.4
HEXTRAN 38 70 200 112 69.6 14.7 886.2 1274.5 315.7
Example
2
M1 207 189 150 168 31.5 7.3 2212.6 5594.1 656.8
M2 207 188 150 169 31.5 7.8 2466.0 8623.3 713.5
M3 207 188 150 169 31.5 5.5 2466.0 9704.5 720.1
New 207 188 150 169 31.5 7.9 2275.4 8541.3 692.0
Model
HTRI 207 189 150 169 39.8 7.9 2161.4 7884.5 674.5
HEXTRAN 207 189 150 170 31.5 8.2 2112.1 8587.4 684.8
Example
3
M1 33 38 48 38 28.6 65.0 4967.7 6400.5 602.0
M2 33 38 48 38 28.6 37.9 5754.6 11419.4 642.0
M3 33 38 48 38 28.6 26.0 5754.6 12155.0 644.0
New 33 38 48 38 28.8 53.4 5754.6 5788.6 608.7
Model
HTRI 33 38 48 38 29.7 45.0 5644.0 5791.8 609.2
HEXTRAN 33 38 48 38 29.3 38.5 5014.5 6667.6 605.1
Y. Wang et al. / Applied Energy 89 (2012) 45–59 55
Table 5
Modelling results: examples 4–6.
Tube-side Shell-side Tube-side Shell-side Tube-side heat transfer Shell-side heat transfer Overall heat transfer
temperature temperature pressure drop pressure drop coefficient (W/(m2 K)) coefficient (W/(m2 K)) coefficient U (W/(m2 K))
(°C) (°C) (kPa) (kPa)
Example 4
M1 210 106 52 82 87.7 96.0 1117.3 1414.2 370.1
M2 210 102 52 83 87.7 70.2 1130.8 1934.6 400.3
M3 210 102 52 83 87.7 56.9 1130.8 2090.3 406.6
New Model 210 102 52 83 87.8 92.7 1393.8 1471.1 408.7
HTRI 210 100 52 83 86.8 97.7 1470.0 1534.0 422.0
HEXTRAN 210 106 52 82 84.9 99.4 1117.2 1434.1 371.5
Example 5
M1 227 195 131 138 55.6 47.3 1574.9 313.6 154.8
M2 227 189 131 140 55.6 30.9 2030.9 536.8 201.8
M3 227 188 131 140 55.6 26.9 2030.9 572.5 206.7
New Model 227 191 131 139 55.6 65.8 2030.9 433.3 185.2
HTRI 227 193 131 139 59.2 76.4 2060.6 371.7 173.3
HEXTRAN 227 189 131 140 56.3 52.4 1574.8 570.9 199.1
Example 6
M1 293 256 196 205 26.0 24.0 1248.2 442.1 164.9
M2 293 251 196 206 26.0 16.7 1595.5 681.3 197.5
M3 293 250 196 206 26.0 14.1 1595.5 735.3 201.8
New Model 293 253 196 206 26.0 29.0 1595.5 562.2 186.1
HTRI 293 254 196 206 27.9 31.1 1604.7 500.5 178.9
HEXTRAN 293 253 196 206 26.3 23.4 1248.1 636.0 186.0
Table 6
Modelling Results: Examples 7–10.
Tube-side Shell-side Tube-side Shell-side Tube-side heat transfer Shell-side heat transfer Overall heat transfer
temperature temperature pressure drop pressure drop coefficient (W/(m2 K)) coefficient (W/(m2 K)) coefficient U (W/(m2 K))
(°C) (°C) (kPa) (kPa)
Example 7
New Model 44 69 194 137 63.1 30.9 1134.1 1613.2 336.9
HTRI 44 70 194 135 59.1 27.8 1310.5 1717.8 359.7
HEXTRAN 44 68 194 141 64.4 27.9 816.5 2036.3 306.0
Example 8
New Model 112 130 227 141 69.5 20.0 1583.2 844.3 310.5
HTRI 112 130 227 142 73.5 17.5 1616.9 745.7 297.6
HEXTRAN 112 130 227 141 71.3 12.8 1217.5 991.7 304.8
Example 9
New Model 121 131 265 160 83.8 16.5 2463.1 980.7 369.6
HTRI 121 131 265 162 91.2 20.5 2494.3 900.6 358.2
HEXTRAN 121 131 265 161 84.1 17.0 1898.9 1066.2 361.3
Example 10
New Model 77 119 170 141 26.1 43.0 7568.7 738.7 321.0
HTRI 77 120 170 140 26.8 38.4 7363.2 809.1 333.3
HEXTRAN 77 120 170 140 25.6 35.7 7145.2 853.3 339.7
zero. If a pinching match is a downstream3 exchanger of the candi- is enhanced, sensitivity analysis is applied again to all candidate
date, then the candidate is not promising. exchangers to find the next best one.
13 12 6 5 1 C1
21 20 18 17 C2
16
30 29 28 27 26 24 4 23 22 C3
H1 17 15
H2 24 20 32
H3 26 16 2
H4 5
H5 22 12 1 7
H6 3 8 9
H7 31
H8 29 27 13 14
H9 28 25
H10 4 18 19
H11 23 10
H12 21 6 11
HU 30
2 25 32 19 15 14 7 11 10 8 9 31 CU
Table 7
Data of HEN in the case study.
8
Ex.26
6
Ex.27
4 5.1. Performance evaluation of heat exchanger model
Ex.28
temperature( )
2
0 The proposed heat exchanger model is compared with three
-1000 -500 0 500 1000 1500 2000 2500 models, namely, Bell-Delaware [13], simplified Tinker [17] and
-2
-4
Wills–Johnston [18] and two commercial software, namely, HTRIÒ
-6
and HEXTRANÒ. The details of methods used in the models are pre-
sented in Table 1. Tables 2 and 3 show stream properties and
-8
geometry details of heat exchangers used in Examples 1–10.
-10
Change in UA(W/K) As shown in Tables 4–6, stream temperatures, heat-transfer
coefficients and pressure drops calculated from the proposed mod-
2.5 el are similar to values obtained by HTRIÒ and HEXTRANÒ in most
Change of hot utility inlet
Ex.4 cases. Three models considered in this paper (M1, M2 and M3) may
2
Ex.23 give significantly different results, compared with HTRIÒ and
1.5
temperature( )
Ex.29 HEXTRANÒ.
1 As shown in the tube-side results from the developed model,
0.5 HTRIÒ and HEXTRANÒ, the major difference is in heat-transfer
0 coefficients. The developed model and HTRIÒ method usually give
-400 -200
-0.5
0 200 400 600 higher values than HEXTRANÒ which may use the Colburn correla-
tion (i.e., Nu = 0.023Re0.8Pr1/3) [11] to calculate tube-side heat-
-1
transfer coefficient. Compared with Eq. (4), the Colburn correlation
-1.5
uses a smaller factor to calculate Nusselt number (Nui). For calcu-
Change in UA(W/K)
lating pressure drop, plain tube pressure drop method [12] is used,
Fig. 7. Sensitivity graphs of exchangers in the case study. the values predicted by the proposed model have reasonably a
good agreement with those from HTRIÒ and HEXTRANÒ.
exchanger model. The procedure of the proposed approach is
In shell-side calculations, the developed model and HTRIÒ give
shown in Fig. 5.
similar values in most examples. HEXTRANÒ uses different correla-
tions for the heat-transfer coefficient and friction factor of ideal
5. Case studies tube bank, while HTRIÒ includes a large number of empirical
parameters for heat transfer and flow resistance, and with many
The semi-rigorous heat exchanger model developed in this pa- adjustable parameters, HTRIÒ model can provide a good represen-
per is validated at first. Then, an industrial-scale HEN retrofit prob- tation of the experimental data for shell-side heat transfer and
Table 8
Stream data and geometry of heat exchangers 20, 24, 26 and 28 in the case study.
Table 9
Tube-side heat transfer enhancement for heat exchangers 20, 24, 26 and 28 in the case study.
Table 10
26 and 28, there is no good candidate left from the results of sen-
Comparison between different retrofit designs.
sitivity tables. Rule 4 is now applied to check whether further en-
Retrofit design number Enhanced exchangers Energy saving (kW) ergy saving can be made. From the results of previous rules,
1 Exchangers 20, 24, 26, 28 2240 exchanger 24 is a good candidate constrained by a pinching match
2 Exchangers 24, 26, 28 1327 exchanger 20. So, according to rule 4, both exchanger 24 and ex-
3 Exchangers 20, 24, 26, 28, 29 2654 changer 20 are enhanced.
From the heuristic methodology: Exchangers 20, 24, 26 and 28
are enhanced with hiTRANÒ, a tube-insert using for the enhance-
ment of tube-side and produced by Gal Gavin Ltd.
pressure drop [12]. From the Examples, it has been demonstrated To estimate the enhancement performances of the four
that the proposed model can be used in process engineering and exchangers, the detailed data of the heat exchangers should be gi-
design practice with confidence for predicting heat exchanger ven, as shown in Table 8. In Table 9, the overall heat-transfer coef-
performance. ficient for each enhanced exchanger increases within the
maximum pressure drop constraints. From Table 7, exchangers
5.2. HEN retrofit with HTE 20, 24, 26 and 28 are selected to be enhanced, which achieves
2.2 MW of heat duty reduction in exchanger 30, leading to 3.4%
Fig. 6 presents an existing preheat train for a crude oil distilla- of overall energy saving. It should be emphasised that this saving
tion column in a refinery plant. The retrofit objective is to reduce has been made without any additional topology modification of
the hot utility (H13) consumption, namely, reduce the heat duty the network.
of heat exchanger 30 (target exchanger). The initial data of the Two other retrofit designs have been presented to compare the
HEN can be found in Table 7. Based on these data, the proposed results from our heuristic methodology, as shown in Table 10.
heuristic rules can be utilised to find suitable heat exchangers for Based on the comparison, it can be noted that if network pinch is
enhancement. not enhanced (the second design), the energy saving will decrease
From Rule 1: Heat exchangers 4, 22, 23, 24, 26, 27, 28 and 29 are significantly. When one more normal candidate (exchanger 29) is
located on the same path with the target exchanger are selected for enhanced (the third design), the energy saving does not increase
performing sensitivity analysis. much.
From Rule 2: Fig. 7 presents the sensitivity graphs for all the se-
lected exchangers. Exchanger 24, 26 and 28 with high sensitivity
are regarded as good candidates, exchangers 27 and 29 are normal 6. Conclusion
candidates, and exchangers 4 and 23 are bad candidates with low
sensitivity. Having large CPmin and there is only one exchanger be- Selecting suitable exchangers for enhancement is an efficient
tween exchanger 28 and target utility exchanger, exchanger 28 is way to solve large-scale HEN retrofit problems. This paper presents
the best candidate. Although exchanger 29 is in nearest position a new approach for HEN retrofit with HTE. First of all, a mathemat-
to target utility exchanger, it is not the best candidate due to its ical model has been developed to predict shell-and-tube heat ex-
normal sensitivity results. changer performances, with which heat-transfer coefficients and
From Rule 3: Exchangers 20, 22 and 23 are pinching matches in pressure drops for both fluids in tube-side and shell-side can be
the HEN. Pinching match of Exchanger 20 is downstream of prom- estimated with satisfactory accuracy. Then, four heuristic rules
ising candidate Exchanger 24, therefore, Exchanger 24 is con- have been proposed to screen candidates for heat transfer
strained by the pinching match. enhancement of exchangers in HEN, which can reduce problem
From the results of sensitivity tables, exchangers 24, 26 and 28 complexity significantly. In contrast to the available design meth-
are good candidates. From Rule 3, exchanger 24 is constrained by ods, the proposed retrofit approach provides realistic solutions for
pinching match exchanger 20 and exchanger 28 is the best candi- HEN retrofit based on intensified heat transfer with substantial en-
date without being constrained by a pinching match. Exchanger 28 ergy saving without topology modification of HEN. A case study
should be enhanced first, and then after applying sensitivity tables shows that, based on the new approach, about 3.4% of energy
again, exchanger 26 is the next best candidate after the enhance- reduction has been achieved in such a high energy consumption
ment of exchanger 28. After the enhancement of both exchangers network. To extend the new approach, more retrofit aspects,
Y. Wang et al. / Applied Energy 89 (2012) 45–59 59
shell-side enhancement and capital costing will be addressed in fu- [12] Serth RW. Design of shell-and-tube heat exchangers. In: Serth RW, editor.
Handbook of process heat transfer principles and applications. Elsevier Ltd.;
ture work.
2007. chapter 5.
[13] Taborek J. Shell-and-tube heat exchangers. Heat exchanger design handbook,
Acknowledgement vol. 3. New York: Hemisphere Publishing Corp.; 1988.
[14] Gnielinski A, Zukauskas A, Skrinska A. Banks of plain and finned tubes. Heat
exchanger design handbook, vol. 2. New York: Hemisphere Publishing Corp.;
Financial support from Research Councils UK Energy Pro- 1998.
gramme (EP/G060274/1 Intensified Heat Transfer for Energy Sav- [15] Ayub ZH. A new chart method for evaluating single-phase shell side heat
ing in Process Industries) is gratefully acknowledged. transfer coefficient in a single segmental shell and tube heat exchanger. Appl
Therm Eng 2005;25:2412–20.
[16] Kern DQ, Kraus AD. Extended surface heat transfer. New York: McGraw-Hill;
References 1972.
[17] ESDU Ltd., Baffled shell-and-tube heat exchangers; flow distribution, pressure
[1] Polley GT, Reyes Athie CM, Gough M. Use of heat transfer enhancement in drop and heat transfer coefficient on the shell side. London: ESDU
process integration. Heat Recov Syst CHP 1992;12(3):191–202. International Ltd.; 1984.
[2] Zhu X, Zanfir M, Klemes J. Heat transfer enhancement for heat exchanger [18] Wills MJN, Johnston D. A new and accurate hand calculation method for shell-
network retrofit. Heat Transfer Eng 2000;21(2):7–18. side pressure drop and flow distribution. In: Proc 22nd national heat transfer
[3] Smith R, Jobson M, Chen L. Recent development in the retrofit of heat conference, vol. 36. American Society of Mechanical Engineers; 1984. p.
exchanger networks. Chemical Engineering Transactions 2009;18:27–32. 67–79.
[4] Li BH, Chang CT. Retrofitting heat exchanger networks based on simple pinch [19] Pan M, Qian Y, Li X. A novel precedence-based and heuristic approach for
analysis. Ind Eng Chem Res 2010;49:3967–71. short-term scheduling of multipurpose batch plants. Chem Eng Sci
[5] Yee TF, Grossmann IE. A screening and optimization approach for the retrofit of 2008;63:4313–32.
heat exchanger networks. Ind Eng Chem Res 1991;30(1):146–62. [20] Pan M, Li X, Qian Y. New approach for scheduling crude oil operations. Chem
[6] Sorsak A, Kravanja Z. MINLP retrofit of heat exchanger networks comprising Eng Sci 2009;64:965–83.
different exchanger types. Comput Chem Eng 2004;28:235–51. [21] Pan M, Li X, Qian Y. Continuous-time approaches for short-term scheduling of
[7] Ponce-Ortega JM, Jiménez-Gutiérrez A, Grossmann IE. Optimal synthesis of network batch processes: Small-scale and medium-scale problems. Chem Eng
heat exchanger networks involving isothermal process streams. Comput Chem Res Des 2009;87:1037–58.
Eng 2008;32:1918–42. [22] Linnhoff B, Townsend DW, Boland D, Hewitt GF, Thomas BEA, Guy AR, et al. A
[8] Asante NDK, Zhu XX. An automated approach for heat exchanger network user guide on process integration for the efficient use of energy. IChemE,
retrofit featuring minimal topology modifications. Comput Chem Eng Rugby, UK; 1982.
1996;20:S7–S12. [23] Linnhoff B, Hindmarsh E. The pinch design method of heat exchanger
[9] Kovac KA. Optimization of an industrial retrofitted heat exchanger network, networks. Chem Eng Sci 1983;38:745–63.
using a stage-wise model. Energy, in press. doi:10.1016/j.energy.2010.09.016. [24] Varbanov PS, Klemes J. Rules for paths construction for HENs debottlenecking.
[10] Cal Gavin Ltd. hiTRANÒ thermal systems: changing fluid dynamics and Appl Therm Eng 2000;20(15):1409–20.
harnessing the benefits. Technical report of Cal Gavin Ltd.; 2009. [25] Kotjabasakis E, Linnhoff B. Sensitivity tables for the design of flexible processes
[11] Bhatti MS, Shah RK. Turbulent and transition convective he at transfer in ducts. (1)-how much contingency in heat exchanger networks is cost-effective. Chem
In: Kakac S, Shah RK, Aung W, editors. Handbook of single-phase convective Eng Res Des 1986;64(a):197–211.
heat transfer. New York: Wiley; 1987 [chapter 4].