You are on page 1of 2

EMI / EMC Test Parameters

Electrical Fast Transient/Burst Immunity Test: (IEC: 61000-4-4)


 Pulse : 5/50ns
 Burst Duration : 15ms
 Burst Period : 300ms
 Pulse repetition Test on Power Line : 2.5KHz
 Amplitude : 4.0KV
 Pulse Repetition Test on Communication and signal lines: 5.0KHz
 Amplitude : 2.0KV

Surge Test: (IEC-61000-4-5)


 Pulse : 1.2/50uSec
 Amplitude : 4.0 KV
 Polarity : Positive & Negative

Electrostatic Discharge Test: (IEC-61000-4-2)


 Contact Discharge : 6KV
 Air Discharge : 8KV
 No. of Discharge : 10
 Polarity : Positive & Negative

Radiated Susceptibility Test: (IEC-61000-4-3)


 Frequency Range : 80MHz -1000MHz
 Field Strength : 10V/m
 Amplitude Modulation : 80% at 1KHz sinusoidal
EMI EMC Standards List

Here is the list of common EMI EMC Standards:

Applications Common EMI EMC Standards

Medical IEC 60601-1-2

Automotive SAE, ISO7637, IEC CISPR-25, ISO1145-1, ISO1145-2

MIL-STD-461, DEF STAN 59/411, MIL-STD-704, MIL-STD-1275,


Military
MIL-STD-1399

Industrial FCC Part 15 class A, EN 61000-6-4 (generic), EN 61000-6-2(generic)

Commercial FCC Part 15 class B, EN 61000-6-3 (generic), EN 61000-6-1(generic)

Switchgear and control EN/IEC 60947-1

Power station and


substation IEC TS 61000-6-5

Process control and


measurement EN/IEC 61326-1

You might also like