Professional Documents
Culture Documents
Quick Tips
Ordering Valley Control Panels
• ICON Series, ClassicPlus and Classic control panels can be
e
built-to-order out of the Valley, NE manufacturing location. n.
This means that selected options will be factory installed,,
saving you labor in the field.
• To order a “Built-to-Order” control panel, it must be submitted
d
on a special EP (Electrical Panel) order type out of the Valley,
y,
NE location. Only one type of control panel can be placed per “EP” order type. However, if you order a
quantity of control panels that are exactly the same, they can be placed on the same order.
• You will notice that “Stock” panels are offered that give you a panel without or with limited options and can
be ordered through any of the 4 Distribution Centers. Field installed options can be ordered separately to
upgrade your control panel to your customer’s requirements.
Call any order manager or Distribution Center Manager for assistance in ordering
control panels!
5 years from the date of purchase on the entire panel, including all electronic and
ICON electromechanical components inside the panel. (fuses and transient voltage
Series protection components not covered)
Component Parts for the ICON Series Control Panels sold through the aftermarket for rebuild or repair
All warranties described herein are for parts only, FOB Valley, NE. No labor or freight allowances
included.
Key Features:
• 5-inch, full-color touchscreen display
How to Order: • Intuitive user interface
Step 1: Select one fo the following control panels based on • Soft touch buttons for feature selection and navigation
cellular provider. • AgSense® Enabled – AgSense ICON Link installed standard*
• BaseStation3™ compatible*
Step 2: Order other components such as Fuses, Pressure
• Variable rate irrigation (VRI) equipped
Transducer, Positioning, Encoder, J-Pipes, Collector
• Cable theft monitoring*
Ring and Pivot Mounting Hardware if needed.
*Additional hardware or subscription required.
*Fuses must be ordered seperately when ordering a panel
through Aftermarket
How to Order:
Step 1: Select one fo the following control panels based on cellular provider.
Step 2: Order other components such as Fuses, Pressure Transducer, Positioning,
Encoder, J-Pipes, Collector Ring and Pivot Mounting Hardware if needed.
Step 3: Must order Wifi package.
*Fuses must be ordered separately when ordering a panel through Aftermarket
Will shut down the machine if one of the three phases of 480
Phase Loss Contactor Option for 30 voltage is lost. (option included in all 45 amp panels). Field Install
932K373 amp panels Yes - KA01603.
KA09012 Service/Run Switch Kit No Includes rocker switch and field install guide.
How to Order:
Step 1: Select one of the following control panels.
Step 2: Select the appropriate panel options if required.
Step 3: Order other components such as J-Pipes, collector rings and pivot
mounting hardware if needed.
ClassicPlus 30 Amp Control Part # for “Build to Order” Control Panels from Valley, NE.
KA01647 Panel with Auto-Reverse Option Some options can be factory installed.
ClassicPlus 45 Amp Control Part # for “Build to Order” Control Panels from Valley, NE.
KA01675 Panel with Auto-Reverse Option Some options can be factory installed.
See
Auxiliary See the “Auxiliary Control Options for Control Panels” Section
Options Auxiliary Control Options Yes for a complete listing.
Provides lightning protection on the incoming 480 volt power
0000654 Lightning Arrestor Field Install Kit No lines. Mounts under the panel.
Includes oscillator lightning protection and wiring harness.
931K007 Corner Panel Option Yes (does not include oscillator)
Monitors the incoming voltage and will shut pivot down if
932K372 Low Voltage Monitor Option Yes voltage drops below a pre-set point. Field Install - KA01602.
03E1802 Solid State Percentage Timer Option No Solid state timer, adjustable for 15, 30, 60 or 120 sec ranges.
For applications in Canada requiring ground fault protection.
932K370 Ground Fault Protection (C.S.A. Option) Yes Field Install - KA01600.
Phase Loss Contactor Option for 30 amp Will shut down the machine if one of the three phases of 480
932K373 panels Yes voltage is lost. (option included in all 45 amp panels)
931K531 Delay Timer Auto Restart No Pivot must have Low Pressure Switch Installed
Includes pressure switch, relay, relay socket, rocker switch
0000M71 Pressure Remote Restart No and hardware for field installation.
A Valley Classic Control Panel has 1 open rectangular rocker switch slot for an auxiliary control option.
Low Pressure Switch Field Install Kit This is a mechanical pressure switch. Includes switch to
931K900 (Low Range 0.6-15 psi) No be mounted in panel, tubing and mounting hardware.
Note: Classic Control Panels will only allow for one auxiliary option to be installed.
ICON10
ICON5
ICON1
ICONX
ClassicPlus
Classic
Examine the existing collector ring on the non-Valley machine. It will either
be an external collector ring (which means mounted on top of the pivot elbow)
or the “Zimmatic®” style that is an integral part of the elbow as illustrated in
the photo. If the collector ring is in good shape, the existing one can be used.
If the external collector ring needs replacing, select a collector ring choice
from the following table. (refer to the electrical section for more collector ring
options and details)
PROCEED TO STEP 5
Valley offers a Valley GPS positioning option with ICON Series panels.
GPS positioning was introduced in 2008 and has proven to be an accurate alternative to
resolver/encoder positioning. The positioning package provides accuracy of +/- 10 feet
(3 meters) with most installations at greater accuracy. When converting a non-valley
control panel, this is an excellent way to lower installation costs and enhance control
capabilities.
Situation 1
Pivots WITH an external collector ring (those installed on top of
the pivot elbow like a Valley).
ICON Series control panels require the installation of the encoder. A encoder
must be installed in an external collector ring. If the non-Valley machine has an
external collector ring, examine the collector ring to ensure that the resolver can
be installed. Here are 2 9 points to keep in mind:
9 If in doubt that the collector ring will support the installation of the encoder
hardware or if the collector ring is worn, then install a new one (refer to the
table illustrated in Step 2).
PROCEED TO STEP 5
Copyright © 2021 Valmont Industries, Inc.
2-17
Control Panels and Options Converting Control Panels on Non-Valley Machines
Situation 2
Pivots WITHOUT an external collector ring.
If the pivot point is not equipped for an external collector ring, then you must
install one. This requires some minimal cutting and welding to install a J-Pipe.
Once the J-Pipe is installed, the new collector ring is easily added.
The following items are required to install an external collector ring on a non-Valley center pivot:
PROCEED TO STEP 5
Copyright © 2021 Valmont Industries, Inc.
2-18
Converting Control Panels on Non-Valley Machines Control Panels and Options
Vertical
Mounting
Bracket
Angle
Mounts
CommanderVP and Valley GPS for Pro/Select Series Panel Upgrade Packages
Part # Description Comments
0000M31 PKG Valley GPS with Commander VP - LTE/VZW Includes CommanderVP, Valley GPS, and Hardware
0000M32 PKG Valley GPS with Commander VP - Aeris Includes CommanderVP, Valley GPS, and Hardware
0000M33 PKG Valley GPS with Commander VP - LTE/AT&T Includes CommanderVP, Valley GPS, and Hardware
ICON5 and ICON10 with Valley GPS and End of Field Pressure Upgrade Packages
Part # Description Comments
Module, SRB, and Icon Link with Valley GPS and End of Field
0000M34 PKG Upgrade ICON5/ Valley GPS/ ICON Link LTE/VZW Pressure
Module, SRB, and Icon Link with Valley GPS and End of Field
0000M51 PKG Upgrade ICON5/ Valley GPS/ ICON Link LTE/AT&T Pressure
Module, SRB, and Icon Link with Valley GPS and End of Field
0000M55 PKG Upgrade ICON5/ Valley GPS/ ICON Link /Aeris Pressure
Module, SRB, and Icon Link with Valley GPS and End of Field
0000M68 PKG Upgrade ICON10/ Valley GPS/ ICON Link LTE/VZW Pressure
Module, SRB, and Icon Link with Valley GPS and End of Field
0000M67 PKG Upgrade ICON10/ Valley GPS/ ICON Link LTE/ AT&T Pressure
Module, SRB, and Icon Link with Valley GPS and End of Field
0000M75 PKG Upgrade ICON10/ Valley GPS/ ICON Link /Aeris Pressure
Note: A Pressure Transducer at the Pivot Point is not included and can be ordered seperately if needed (933K431).
Contact the Aftermarket Parts Department with any questions.
03E3933 USB Panel Mount Cable Single Terminal - Only used with the ICON5
USB Panel Mount Cable Double Terminal - Only used with the ICON1
03E3934
and ICON10