Since the sign conventions of these forces is that of forces acting on the elements, it is
necessary to reverse the signs to get the forces and moments acting on the turbine
nozzles at points 35 and 50, or:
When running the NEMA portion of the ROT program, there are two input spreadsheets
upon which descriptive and load data must be entered, which in this case would be filled
out as shown in Figure 3-56.
The program then proceeds to check the loading on each nozzle, and then resolves the
loads about the discharge and checks the cumulative loading on an equivalent nozzle,
as described above. The two page NEMA output report for this particular example is
shown in Figure 3-57.The results first show that the discharge nozzle passed (only
reaching 30.4% of the allowable), the suction nozzle passed (reaching 49% of the
allowable), and the cumulative load passed, with the highest summation load (Z-
moment) reaching only 56% of the allowable. If the turbine had failed, the symbol
**FAILED** would have appeared in the "STATUS" column next to the load combination
that was excessive.