You are on page 1of 8

PRODUCT CONFORMITY CERTIFICATE

This is to certify that the

Codel GCEM 40
Manufactured by:

Codel International Ltd,


Station Road
Bakewell
Derbyshire
UK

has been assessed by CSA Group


and for the conditions stated on this certificate complies with:

Environment Agency Guidance


“MCERTS for stack emissions monitoring equipment at industrial installations”
- Continuous emissions monitoring systems(CEMS)
Published 20 October 2020
EN 15267-1:2009, EN15267-2:2009, EN 15267-3:2007
& QAL 1 as defined in EN 14181: 2014

Certification ranges:

CO 0 to 500ppm 0 to 1000ppm
NO 0 to 500ppm 0 to 1000ppm
SO2 0 to 500ppm 0 to 1000ppm

Project number: 80095466


Certificate number: Sira MC160296/01
Initial certification: 17 May 2016
This certificate issued: 11 August 2021 Andrew Young
Renewal date: 16 May 2026 Environmental Team Manager
MCERTS is operated on behalf of the Environment Agency by
CSA Group Testing UK Ltd
Unit 6, Hawarden Industrial Park
Hawarden, Deeside, CH5 3US
Tel: +44 (0)1244 670 900

The MCERTS certificate consists of this document in its entirety.


For conditions of use, please consider all the information within.
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 1 of 8
Form 1335
Issue 10
Certificate Contents
Approved Site Application ........................................................................................................ 2
Basis of Certification ............................................................................................................... 2
Product Certified..................................................................................................................... 3
Certified Performance ............................................................................................................. 4
Description............................................................................................................................. 8
General Notes ........................................................................................................................ 8

Approved Site Application

Any potential user should ensure, in consultation with the manufacturer, that the monitoring system
is suitable for the intended application. For general guidance on monitoring techniques refer to the
Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net

On the basis of the assessment and the ranges required for compliance with EU Directives this instrument is
considered suitable for use on waste incineration and large coal-fired combustion plant applications. This CEM
has been proven suitable for its measuring task (parameter and composition of the flue gas) by use of the QAL
1 procedure specified in EN14181, for LCPD/IED Chapter III and IED Chapter IV applications for the ranges
specified. The lowest certified range for each determinant shall not be more than 1.5X the daily average
emission limit value (ELV) for IED Chapter IV applications, and not more than 2.5X the ELV for IED Chapter
III and other types of application.

The field test was carried out over a period of 4 months and 10 days in the exhaust gas of a coal
fired power plant upstream of desulphurization.

Basis of Certification

This certification is based on the following Test Report(s) and on Sira’s assessment and ongoing
surveillance of the product and the manufacturing process:

TUV Rheinland Report No: 936/21222744/A

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 2 of 8
Product Certified

The GCEM 40 measuring system consists of the following parts:

1. GCEM 40 Series Transceiver Head


2. GCEM 40 Series Probe
3. GCEM 40 Series Pneumatics Panel
4. Data Display Unit with 4 core comms cable
5. Site Mounting Flange – BS4505 PN16 DN200
6. Site Mounting Flange Gasket with bolts
7. Power Cable

The Data Display Unit (or DDU) is the customer interface providing the flowing;

1. 5 x 4 to 20ma outputs
2. 5 x volt-free SPCO contacts
3. 1 x volt-free SPCO contact for Data Valid
4. 1 x RS485 Modbus output
5. 1 x 2 line display

This certificate applies to all instruments fitted with software versions;

1. 507-108A DDU
2. 507-066A Transceiver Head Slave
3. 507-067A Transceiver Head Master
4. 507-065A Controller Master

This certificate applies to all instruments with following Serial number onwards;

GCEM40 -1000

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 3 of 8
Certified Performance

The instrument was evaluated for use under the following conditions:

Ambient Temperature Range: -20°C to +50°C


Instrument IP rating: IP66

Results are expressed as error % of certification range, unless otherwise stated.


Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Response time

CO (0 to 500ppm) 172s <200s

CO (0 to 1000ppm) 163s <200s

NO (0 to 500ppm) 191s <200s

NO (0 to 1000ppm) 185s <200s

SO2 (0 to 500ppm) 186s <200s

SO2 (0 to 1000ppm) 177s <200s

Repeatability standard deviation at zero


point

CO 0.0 <2.0%

NO 0.1 <2.0%

SO2 0.4 <2.0%

Repeatability standard deviation at


reference point

CO 0.2 <2.0%

NO 0.3 <2.0%

SO2 0.3 <2.0%

Lack-of-fit

CO (0 to 500ppm) 0.8 <2.0%

CO (0 to 1000ppm) 0.5 <2.0%

NO (0 to 500ppm) -0.6 <2.0%

NO (0 to 1000ppm) 0.4 <2.0%

SO2 (0 to 500ppm) 0.4 <2.0%

SO2 (0 to 1000ppm) -0.5 <2.0%

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 4 of 8
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Influence of ambient temperature zero
point
(-20°C to +50°C)

CO 0.2 <5.0%

NO 1.0 <5.0%

SO2 3.8 <5.0%

Influence of ambient temperature


reference point
(-20°C to +50°C)

CO 1.8 <5.0%

NO 1.6 <5.0%

SO2 3.8 <5.0%

Influence of sample gas pressure

CO 0.37 <2.0%

NO -0.29 <2.0%

SO2 0.71 <2.0%

Influence of voltage variations Zero point


(196V to 253V)

CO -0.2 <2.0%

NO 0.5 <2.0%

SO2 1.0 <2.0%

Influence of voltage variations Span


point (196V to 253V)

CO 0.4 <2.0%

NO -0.4 <2.0%

O2 0.8 <2.0%

Influence of vibration Zero point To be reported

CO 0.0

NO -0.1

SO2 0.1

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 5 of 8
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Influence of vibration Span point

CO -1.1

NO -1.6

SO2 1.8

Cross-sensitivity at zero with


interferents: O2, H2O, CO, CO2, CH4,
N2O, NO, NO2, NH3, SO2, HCl

CO 0.0 <4.0%

NO 0.0 <4.0%

SO2 -3.58 <4.0%

Cross-sensitivity at reference with


interferents: O2, H2O, CO, CO2, CH4,
N2O, NO, NO2, NH3, SO2, HCl

CO 1.4 <4.0%

NO -1.8 <4.0%

SO2 -3.4 <4.0%

Measurement uncertainty Guidance - at least 25% below max


permissible uncertainty
CO (For and ELV of 50 mg/m3) 7.4% <7.5% (10%)

NO (For and ELV of 130 mg/m3) 15% <15% (20%)

SO2 (For and ELV of 50 mg/m3) 15% <15% (20%)

Calibration function (field)

CO 0.91 >0.90

NO 0.94 >0.90

SO2 0.96 >0.90

Response time (field)

CO 182s <200s

NO 189s <200s

SO2 195s <200s

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 6 of 8
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Lack of fit (field)

CO 1.2 <2.0%

NO -1.4 <2.0%

SO2 -0.6 <2.0%

Maintenance interval 4 weeks >8 days


Zero and Span drift requirement Clause
The probe is designed with inlet ports that allow either 6.13 & 10.13
a zero gas (typically dry compressed air) or a
calibration gas to be injected into the measurement Manufacturer
chamber to replace the flue gases. Integral solenoid shall provide a
valves controlled by the sensing head automatically description of
introduce the zero and span gas. the technique to
determine and
The zero point is verified automatically every 24hrs compensate for
and any drift is compensated for and reported. zero and span
drift
The span point can be verified when required by
injecting calibration gas; this can be done
automatically or manually.

Change in zero point over maintenance


interval

CO 1.4 <3.0%

NO 3.0 <3.0%

SO2 3.0 <3.0%

Change in reference point over


maintenance interval

CO 3.0 <3.0%

NO 2.9 <3.0%

SO2 3.0 <3.0%

Availability
97.1% >95%

Reproducibility

CO 0.8 <3.3%

NO 1.6 <3.3%

SO2 2.3 <3.3%

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 7 of 8
Description

The AMS Codel GCEM 40 Series is an IR analyser; it uses an insitu probe set into the flue gas duct
or stack to measure the emission levels of the selected gases within the flue gas. The probe includes
a measurement cell that allows flue gas to diffuse into the optical measurement path of the analyser.
A transceiver unit mounted on the probe transmits a beam of infrared energy down the probe through
the measurement cell to a reflector that directs the beam back to the transceiver. Analysis of the
received energy beam by NDIR technology provides a continuous measurement of the levels of the
selected emissions within the flue gas.

General Notes

1. This certificate is based upon the equipment tested. The Manufacturer is responsible for
ensuring that on-going production complies with the standard(s) and performance criteria
defined in this certificate. The manufacturer is required to maintain an approved quality
management system controlling the manufacture of the certified product. Both the product
and the quality management system shall be subject to regular surveillance according to
‘Regulations Applicable to the Holders of CSA Group Testing UK Ltd Certificates’.

2. The design of the product certified is held and maintained by TUV Rheinland for certificate No.
Sira MC160296/01.

3. If a certified product is found not to comply, CSA Group should be notified immediately at the
address shown on this certificate.

4. The certification marks that can be applied to the product or used in publicity material are
defined in ‘Regulations Applicable to the Holders of CSA Group Testing UK Ltd Certificates’.

5. This document remains the property of CSA Group and shall be returned when requested by
CSA Group.

Certificate No: Sira MC160296/01


This Certificate issued: 11 August 2021

This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts

Page 8 of 8