1 EC TYPE-EXAMINATION CERTIFICATE
2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC
II (1)GD
[EEx ia] IIC (Ta = -20°C to +70°C)
SCHEDULE
13 DESCRIPTION OF EQUIPMENT
The Trendmaster Galvanic Isolator (TMGI) is associated apparatus that provides isolated intrinsically
safe outputs for connection to suitably-certified transducers. The TMGI is housed in a flame retardant
urethane enclosure and is designed to be installed in a location that provides protection against water
and windblown dust.
The power lines are nominally 15 Vac NRZ (Non-Return to Zero) and the transducers are addressed by
switching the power lines. The signal lines are nominally 3 Vac NRZ when transmitting data and up to
5 V analogue when reading the transducer signal.
The equipment has a maximum input voltage under fault conditions (Um) of 250 Vac and has the
following safety description at its intrinsically safe outputs:
Power Signal + Signal - Combined output
(terminal 2 (terminal 5 (terminal 4 parameters of
with respect to with respect to with respect to terminals 2, 4 & 5 with
terminal 3 (TIM terminal 3 (TIM COM)) terminal 3 (TIM COM)) respect to terminal 3
COM)) (TIM COM)
Uo (V) ±14.34 ±9.56 ±9.56 23.9
Io (mA) 142 9.5 9.5 161
Po (mW) 510 22.5 22.5 555
IIA IIB IIC IIA IIB IIC IIA IIB IIC IIA IIB IIC
Co in (µF)
15.8 4.18 0.67 210 26 3.6 210 26 3.6 3.38 0.94 0.126
Lo/Ro
(µH/Ω) 560 280 70 12688 6344 1586 12688 6344 1586 168 84 21
The installer should note that, if two or all three outputs are connected together, the combined output
is intrinsically safe for IIC gases and vapours. However, the maximum voltage for intrinsic safety
purposes is that obtained assuming one of the outputs is positive and the other output is negative.
Variation 1 - This variation introduced the following changes:
i. To allow the increase in the value of fuse F4 on Board 1 from 100 mA to 200 mA.
ii. The introduction of minor circuit changes to Board 2.
iii. To recognise changes to the label drawing.
Variation 2 - This variation introduced the following change:
i. The applicants name and address was changed from Bently Nevada Corporation 1617 Water
Street to that currently shown.
SCHEDULE
14 DESCRIPTIVE DOCUMENTS
14.1 Drawings
Refer to Certificate Annexe.
14.2 Associated Sira Reports and Certificate History
Issue Date Report number Comment
0 24 October 2003 R52A9063A The release of the prime certificate.
1 12 March 2004 RError! The introduction of Variation 1.
Reference
source not
found.A
2 15 July 2005 R52V12590A Re-issued to incorporate Variation 1 and report
R52V12590A
3 28 January 2010 R21692A/00 This Issue covers the following changes:
• All previously issued certification was rationalised
into a single certificate, Issue 3, Issues 0 to 2
referenced above are only intended to reflect the
history of the previous certification and have not
been issued as documents in this format.
• The introduction of Variation 2.
15 SPECIAL CONDITIONS FOR SAFE USE (denoted by X after the certificate number)
None
16 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II (EHSRs)
The relevant EHSRs that are not addressed by the standards listed in this certificate have been
identified and individually assessed in the reports listed in Section 14.2.
17 CONDITIONS OF CERTIFICATION
17.1 The use of this certificate is subject to the Regulations Applicable to Holders of Sira Certificates.
17.2 Holders of EC type-examination certificates are required to comply with the production control
requirements defined in Article 8 of directive 94/9/EC.
17.3 The Trendmaster Galvanic Isolator (TMGI) covered by this certificate incorporate previously certified
devices, it is therefore the responsibility of the manufacturer to continually monitor the status of the
certification associated with these devices, and the manufacturer shall inform Sira of any modifications
of the devices that may impinge upon the explosion safety design of the Trendmaster Galvanic Isolator
(TMGI).
17.4 The manufacturer shall substitute, on the approved label affixed to the apparatus, the new company
name and address for the old company name and address.
Issue 0 and 1 The drawings associated with these issues were incorporated into Issue 2
Issue 2
Drawing No. Sheet Rev. Date Title
162459 1 of 1 - 24 Sep 03• General arrangement
162472 1 of 1 D 12 Mar 04• Label
162464 1 of 8 G 04 Mar 04• Artwork – board 1
162464 2 of 8 G 04 Mar 04• Artwork – board 1
162464 3 of 8 G 04 Mar 04• Artwork – board 1
162464 4 of 8 G 04 Mar 04• Artwork – board 1
162464 8 of 8 G 04 Mar 04• Artwork – board 1
162495 1 of 8 D 04 Mar 04• Artwork – board 2
162495 2 of 8 D 04 Mar 04• Artwork – board 2
162495 3 of 8 D 04 Mar 04• Artwork – board 2
162495 4 of 8 D 04 Mar 04• Artwork – board 2
162495 8 of 8 D 04 Mar 04• Artwork – board 2
162525 1 to 5 E 04 Mar 04• Schematic – board 1
162526 1 to 5 D 05 Jan 05• Schematic – board 2
162527 1 of 1 B 05 Jan 05• Conformal coating – board 2
129806 1 of 1 A 22 May 96 PWB material finish
00309015 1 of 1 - 24 Sep 03• Transformer construction
• This is the date that the drawing was stamped by Sira.
Issue 3 No new drawings were introduced.