ACH550-With Harmonic Filter Product Brochure
ACH550-With Harmonic Filter Product Brochure
ABB’s latest offering for harmonic miti- Highlights Voltage and power range
gation is the ABB ACH550 drive with a −− Compact & slim design −− 3-phase, 208 to 240 V, 7.5 to 100Hp
new integrated harmonic filter option. The −− UL508A labeled with 100 KAIC SCCR −− 3-phase, 480 V, 7.5 to 550Hp
ACH550, with the new option, will maintain −− Current distortion limited to less than −− 3-phase, 500 to 600 V, 15 to 150Hp
harmonic current distortion to below 7% at 7%, while improving true power factor
the input terminals of the drive. We have −− Unique Harmonic Filter Design virtually Options
integrated the Harmonic Filter option into eliminates the possibility of leading −− Fieldbus adapters
our ACH550 Packaged Drive offering using power factor interfering with other −− Panel mounting kits
a circuit breaker or disconnect, or along equipment at light loads −− 3 Relay extension module (OREL-01)
with ABB’s ACH550 and Eclipse Bypass, −− Voltage drop on the ACH550 DC Bus −− 115/230 V Digital Input Interface card
while maintaining a UL Short circuit rating is less than 2% at full load (OHDI-01)
of 100KAIC. −− Harmonic filter operates only when −− Fieldbus Adapters
needed: it operates in drive mode; −− LonWorks
Saving Cost however, it does not operate in bypass −− Profibus
−− Reduce site installation costs with an mode, allowing the motor to start −− DeviceNet
integrated design without incident. −− Ethernet
−− Eliminate complexity of adding a harmo- −− Standard ACH550 options available −− ControlNet
nic filter to a drive with bypass −− Option is covered by ABB’s Certified −− BACnet IP to MS/TP router
−− Extend the drive‘s warranty when com- Start Up warranty providing a 24/30 −− DriveWindow Light
missioned by an ABB Certified Start Up warranty
technician
ACH550 Drives Models where the Harmonic Input power connection
Filter (+E211) may be included:
Voltage and Power Range 3-phase, 208 to 240 V, +/-10%
3-phase, 480 V, +/-10%
−− ACH550- PCR / PDR + E211 3-phase, 500 to 600V, +/-10%
−− NEMA 1, 12 & 3R Enclosures Frequency 48 to 63 Hz
−− 3 Phase, 480 V, 7.5 to 550 HP Power Factor 0.98 at nominal load
−− 3 Phase, 208 to 240 V, 7.5 to 100 HP Harmonic Content with E211 har- Typically 5 to 7% TDD at drive input terminals
−− 3 Phase, 600 Vn 15 to 150 HP monic Filter
(available as engineered solution) Motor connection
−− E-Clipse Bypass with Input Circuit Two analog outputs 0 (4) to 20 mA, load < 500 Ω
Breaker (BCR) Auxiliary voltage 24 V DC, max. 250 mA (short circuit protected)
−− E-Clipse Bypass with Non-Fused Input Six digital inputs 12 to 24 V DC with internal or external supply,
Disconnect (BDR) PNP and NPN
Three relay outputs (Form C)
Maximum switching voltage 250 VAC/30 V DC
Maximum switching current 8 A at 24 VDC or 250 VAC, or 0.4 at 120 VDC
Maximum continuous current 2 A RMS
Serial communication
Four Resident Serial Communica- Johnson Controls N2 Bus
tion Protocols Siemens Buildings Technologies FLN (P1)
Modbus RTU
BACnet (MS/TP)
Product compliance
240V products UL, cUL
480V products UL, cUL
600V products UL, cUL
Environmental limits
Protection class UL Type 1 or 12 or 3R (NEMA 1 or NEMA 12
or NEMA 3R)
Ambient temperature 0 to 40oC (5 to 104oF)
(Operating) 40 to 50oC (104 to 122oF) with derate