You are on page 1of 6

Frequent Inspection

This checklist includes items listed that should be inspected on a daily basis before operating an overhead crane,
as well as items that should be expected monthly by a certified crane inspector.

General
REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(2)(i) 01 There are no defects interfering with


proper operation for all functional
operating mechanisms

1910.179(j)(2)(vi) 02 There is no excessive wear on any


components of functional operating
mechanisms

1910.179(j)(2)(vii) 03 The rope is threaded in compliance


with manufacturer’s recommendations

Air/Hydraulic Systems

REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(2)(ii) 04 There are no signs of deterioration or


leakage in hydraulic/air lines

1910.179(j)(2)(ii) 05 There are no signs of deterioration or


leakage in hydraulic/air tanks

1910.179(j)(2)(ii) 06 There are no signs of deterioration or


leakage in hydraulic/air valves

1910.179(j)(2)(ii) 07 There are no signs of deterioration or


leakage in hydraulic/air drain pumps

1910.179(j)(2)(ii) 08 There are no signs of deterioration or


leakage in any other parts of the
hydraulic/air systems

www.VectorSolutions.com ClientSupport@VectorSolutions.com 1.813.207.0012


Items that Require Monthly Certification Record
REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(2)(iii) 09 There is no deformation or cracks


in hooks

1910.179(j)(2)(iii) 10 Hooks are not more than 15


percent in excess of normal
throat opening

1910.179(j)(2)(iii) 11 Hooks are not more than 10-


degree twist from the plane of
the unbent hook

1910.179(l)(3)(iii)(a) 12 Any hooks that have failed items


09, 10, or 11 have been
discarded

1910.179(j)(2)(iv) 13 There are no signs of excessive


wear, twist, or distorted links in
the hoist chains (including end
connections) that would interfere
with proper function.

1910.179(j)(2)(iv) 14 Hoist chains (including end


connections) do not stretch
beyond manufacturer’s
recommendations.

www.VectorSolutions.com ClientSupport@VectorSolutions.com 1.813.207.0012


Periodic Inspection
This checklist includes items listed that should be inspected on yearly or quarterly basis, depending on the
cranes use, as well as on cranes that have not been used for more than a month but less than six months.

General

REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(2)(i) 01 There are no defects


interfering with proper
operation for all functional
operating mechanisms

1910.179(j)(2)(vi) 02 There is no excessive wear on


any components of functional
operating mechanisms

1910.179(j)(2)(vii) 03 The rope is threaded in


compliance with
manufacturer’s
recommendations

Air/Hydraulic Systems

REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(2)(ii) 04 There are no signs of


deterioration or leakage in
hydraulic/air lines

1910.179(j)(2)(ii) 05 There are no signs of


deterioration or leakage in
hydraulic/air tanks

1910.179(j)(2)(ii) 06 There are no signs of


deterioration or leakage in
hydraulic/air valves

1910.179(j)(2)(ii) 07 There are no signs of


deterioration or leakage in
hydraulic/air drain pumps

1910.179(j)(2)(ii) 08 There are no signs of


deterioration or leakage in
any other parts of the
hydraulic/air systems

www.VectorSolutions.com ClientSupport@VectorSolutions.com 1.813.207.0012


Items that Require Monthly Certification Record

REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(2)(iii) 09 There is no deformation or


cracks in hooks

1910.179(j)(2)(iii) 10 Hooks are not more than 15


percent in excess of normal
throat opening

1910.179(j)(2)(iii) 11 Hooks are not more than 10-


degree twist from the plane of
the unbent hook

1910.179(l)(3)(iii)(a) 12 Any hooks that have failed


items 09, 10, or 11 have been
discarded

1910.179(j)(2)(iv) 13 There are no signs of


excessive wear, twist, or
distorted links in the hoist
chains (including end
connections) that would
interfere with proper function.

1910.179(j)(2)(iv) 14 Hoist chains (including end


connections) do not stretch
beyond manufacturer’s
recommendations.

Periodic Specific Items

REFERENCE ITEM DESCRIPTION STATUS COMMENTS

1910.179(j)(3)(i) 15 There are no deformed,


cracked, or corroded members,

1910.179(j)(3)(ii) 16 There are no loose bolts or


rivets

1910.179(j)(3)(iii) 17 The sheaves and drums are


not cracked or worn

1910.179(j)(3)(iv) 18 There are no worn, cracked,


or distorted parts such as
pins, bearings, shafts, gears,
rollers locking and clamping

www.VectorSolutions.com ClientSupport@VectorSolutions.com 1.813.207.0012


devices

1910.179(j)(3)(v) 19 There is no excessive wear on


the brake system parts, linings,
pawls, and ratchets

1910.179(j)(3)(vi) 20 The load, wind, and other


indicators have been tested
over their full range with no
significant inaccuracies found.

1910.179(j)(3)(vii) 21 The gasoline, diesel, electric, or


other powerplants do not
perform improperly

1910.179(j)(3)(vii) 22 The gasoline, diesel, electric, or


other powerplants are in
compliance with applicable
safety requirements

1910.179(j)(3)(viii) 23 There are no signs of excessive


wear of chain drive sprockets
or excessive
chain stretch

1910.179(j)(3)(x) 24 There are no signs of pitting


or any deterioration of
controller contactors, limit
switches and pushbutton
stations in the electrical
apparatus.

www.VectorSolutions.com ClientSupport@VectorSolutions.com 1.813.207.0012


About Vector Solutions
IndustrySafe, a Vector Solutions brand, is a leading provider safety management software provider
for the manufacturing, construction and engineering, transportation, energy, and government
industries. Its highly configurable environmental, health and safety (EHS) management software
suite helps organizations efficiently record, track and trend safety data to improve workplace safety,
ensure regulatory compliance, reduce risks, and save time and costs.

Vector Solutions is a leader in eLearning and performance support, providing award-winning SaaS
solutions. Its extensive online and mobile learning library offers over 9,000 courses written by over
280 subject matter experts and reaches more than 10 million professionals worldwide.

To learn more how Vector Solutions can help you streamline and manage Overhead Crane
Inspections, download the IndustrySafe Mobile App for mobile inspections!

www.VectorSolutions.com ClientSupport@VectorSolutions.com 1.813.207.0012

You might also like