You are on page 1of 17

Firebox Monitor (Cylindrical Heater) Page 1

Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 1 2 3 4 5 6 7 8 9 10 11
Tube number 18 18 18 18 18 18 18 18 18 18 17
Length from tube inlet (m) 0.157 0.664 1.365 2.066 2.767 3.468 4.169 4.870 5.571 6.172 6.673
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 343.37 343.47 343.63 343.84 344.10 344.40 344.67 344.89 345.05 345.15 345.21
Inside wall temperature (C) 354.88 356.22 359.54 364.23 369.52 370.40 366.53 361.66 356.83 353.27 353.40
Outside wall temperature (C) 376.91 380.76 390.40 404.13 419.75 421.87 409.46 394.29 379.53 368.77 368.90
Peak wall temperature (C) 395.61 402.52 417.39 437.69 461.16 466.68 447.46 423.64 400.24 383.12 383.24
Pressure (kPa) 1378.9 1378.6 1378.2 1377.8 1377.4 1377.0 1376.6 1376.2 1375.8 1375.4 1374.4
Pressure drop (kPa) 0.179 0.406 0.404 0.400 0.396 0.393 0.395 0.399 0.404 0.292 0.294
Process HTC (W/m2-K) 1800.9 1805.8 1817.5 1833.8 1851.7 1854.2 1840.5 1823.4 1806.2 1793.1 1792.9
Process reynolds 605242 605653 606315 607162 608242 609462 610594 611501 612166 612572 612839
Area (m2) 0.112 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.180 0.180
Cumulative area (m2) 0.112 0.364 0.616 0.868 1.119 1.371 1.623 1.875 2.126 2.306 2.486
Duty (MegaWatts) 0.0021 0.0052 0.0065 0.0085 0.0107 0.0109 0.0091 0.0069 0.0048 0.0024 0.0024
Cumulative duty (MegaWatts) 0.0021 0.0073 0.0138 0.0223 0.0330 0.0439 0.0530 0.0599 0.0648 0.0671 0.0695
Average flux (W/m2) 18583 20702 26018 33645 42345 43386 36197 27513 19144 13078 13075
Maximum flux (W/m2) 28936 32759 41008 52332 65480 68432 57382 43828 30623 21012 21005
Fraction convection (--) 0.1481 0.1357 0.1437 0.1565 0.1668 0.1664 0.1609 0.1677 0.1695 0.1455 0.1455
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 2
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 12 13 14 15 16 17 18 19 20 21 22
Tube number 17 17 17 17 17 17 17 17 17 16 16
Length from tube inlet (m) 7.274 7.975 8.677 9.378 10.079 10.780 11.481 12.182 12.689 13.002 13.509
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 345.31 345.47 345.69 345.97 346.26 346.52 346.73 346.89 346.99 347.04 347.14
Inside wall temperature (C) 357.22 362.41 367.76 372.20 371.87 367.04 362.71 359.66 358.44 358.43 359.76
Outside wall temperature (C) 379.91 395.01 410.64 423.60 422.01 406.84 393.45 384.10 380.36 380.36 384.20
Peak wall temperature (C) 400.61 424.34 448.60 468.35 463.35 440.31 420.35 405.76 398.97 398.96 405.85
Pressure (kPa) 1374.1 1373.7 1373.3 1372.9 1372.5 1372.1 1371.7 1371.3 1371.0 1370.1 1369.8
Pressure drop (kPa) 0.409 0.405 0.400 0.396 0.394 0.397 0.402 0.406 0.182 0.183 0.408
Process HTC (W/m2-K) 1806.4 1824.2 1842.1 1856.5 1854.9 1838.5 1823.7 1813.2 1809.3 1809.7 1814.6
Process reynolds 613245 613911 614819 615953 617177 618263 619115 619781 620194 620430 620844
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.112 0.112 0.252
Cumulative area (m2) 2.738 2.990 3.241 3.493 3.745 3.996 4.248 4.500 4.612 4.725 4.977
Duty (MegaWatts) 0.0048 0.0069 0.0091 0.0109 0.0106 0.0084 0.0065 0.0052 0.0021 0.0021 0.0052
Cumulative duty (MegaWatts) 0.0743 0.0812 0.0903 0.1012 0.1118 0.1203 0.1268 0.1320 0.1341 0.1362 0.1414
Average flux (W/m2) 19135 27488 36156 43326 42266 33560 25926 20611 18491 18491 20608
Maximum flux (W/m2) 30611 43796 57329 68350 65375 52215 40884 32629 28809 28809 32626
Fraction convection (--) 0.1694 0.1675 0.1606 0.1661 0.1664 0.1560 0.1431 0.1349 0.1474 0.1474 0.1349
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 3
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 23 24 25 26 27 28 29 30 31 32 33
Tube number 16 16 16 16 16 16 16 16 15 15 15
Length from tube inlet (m) 14.210 14.911 15.612 16.313 17.014 17.715 18.416 19.018 19.519 20.120 20.821
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 347.30 347.51 347.77 348.06 348.33 348.55 348.71 348.81 348.87 348.97 349.13
Inside wall temperature (C) 363.07 367.74 373.00 373.88 370.02 365.18 360.37 356.83 356.95 360.75 365.92
Outside wall temperature (C) 393.81 407.52 423.10 425.22 412.82 397.67 382.95 372.22 372.34 383.32 398.39
Peak wall temperature (C) 420.70 440.95 464.37 469.88 450.68 426.91 403.56 386.49 386.60 403.92 427.60
Pressure (kPa) 1369.4 1369.0 1368.6 1368.2 1367.8 1367.4 1367.0 1366.7 1365.7 1365.3 1364.9
Pressure drop (kPa) 0.406 0.402 0.398 0.396 0.397 0.402 0.407 0.294 0.295 0.411 0.407
Process HTC (W/m2-K) 1826.2 1842.3 1860.0 1862.5 1848.9 1832.0 1814.8 1801.8 1801.7 1815.0 1832.7
Process reynolds 621511 622364 623452 624679 625820 626733 627403 627811 628078 628486 629153
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.180 0.180 0.252 0.252
Cumulative area (m2) 5.228 5.480 5.732 5.983 6.235 6.487 6.739 6.919 7.098 7.350 7.602
Duty (MegaWatts) 0.0065 0.0084 0.0106 0.0109 0.0091 0.0069 0.0048 0.0023 0.0023 0.0048 0.0069
Cumulative duty (MegaWatts) 0.1479 0.1563 0.1670 0.1778 0.1869 0.1938 0.1986 0.2010 0.2033 0.2081 0.2150
Average flux (W/m2) 25917 33538 42232 43272 36084 27403 19040 12980 12977 19031 27377
Maximum flux (W/m2) 40872 52187 65328 68274 57228 43679 30484 20882 20876 30469 43648
Fraction convection (--) 0.1430 0.1559 0.1662 0.1658 0.1602 0.1668 0.1683 0.1441 0.1441 0.1682 0.1666
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 4
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 34 35 36 37 38 39 40 41 42 43 44
Tube number 15 15 15 15 15 15 15 14 14 14 14
Length from tube inlet (m) 21.522 22.223 22.924 23.625 24.326 25.027 25.534 25.847 26.355 27.056 27.757
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 349.35 349.62 349.91 350.17 350.37 350.53 350.63 350.69 350.79 350.94 351.15
Inside wall temperature (C) 371.24 375.67 375.34 370.53 366.22 363.19 361.97 361.97 363.29 366.58 371.23
Outside wall temperature (C) 414.00 426.93 425.35 410.21 396.85 387.51 383.78 383.78 387.61 397.20 410.88
Peak wall temperature (C) 451.82 471.54 466.56 443.56 423.64 409.07 402.30 402.29 409.17 423.98 444.19
Pressure (kPa) 1364.5 1364.1 1363.7 1363.3 1362.9 1362.5 1362.2 1361.3 1361.0 1360.6 1360.2
Pressure drop (kPa) 0.402 0.398 0.397 0.399 0.404 0.408 0.183 0.184 0.410 0.408 0.405
Process HTC (W/m2-K) 1850.4 1864.7 1863.2 1846.9 1832.2 1821.7 1817.9 1818.3 1823.1 1834.6 1850.6
Process reynolds 630067 631210 632444 633536 634392 635062 635478 635716 636131 636803 637661
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.252 0.112 0.112 0.252 0.252 0.252
Cumulative area (m2) 7.854 8.105 8.357 8.609 8.861 9.112 9.225 9.337 9.589 9.841 10.092
Duty (MegaWatts) 0.0091 0.0109 0.0106 0.0084 0.0065 0.0052 0.0021 0.0021 0.0052 0.0065 0.0084
Cumulative duty (MegaWatts) 0.2240 0.2349 0.2455 0.2540 0.2605 0.2656 0.2677 0.2698 0.2749 0.2814 0.2898
Average flux (W/m2) 36045 43212 42153 33453 25828 20513 18396 18397 20510 25816 33431
Maximum flux (W/m2) 57174 68192 65224 52070 40746 32497 28680 28680 32494 40733 52042
Fraction convection (--) 0.1599 0.1655 0.1658 0.1554 0.1424 0.1341 0.1467 0.1467 0.1341 0.1423 0.1552
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 5
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 45 46 47 48 49 50 51 52 53 54 55
Tube number 14 14 14 14 14 14 13 13 13 13 13
Length from tube inlet (m) 28.458 29.159 29.860 30.561 31.262 31.863 32.364 32.965 33.666 34.367 35.068
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 351.41 351.70 351.97 352.19 352.35 352.44 352.50 352.60 352.76 352.98 353.25
Inside wall temperature (C) 376.46 377.34 373.50 368.67 363.89 360.37 360.49 364.27 369.41 374.71 379.12
Outside wall temperature (C) 426.43 428.54 416.17 401.04 386.34 375.64 375.76 386.70 401.75 417.33 430.25
Peak wall temperature (C) 467.58 473.06 453.90 430.16 406.86 389.82 389.94 407.22 430.85 455.03 474.72
Pressure (kPa) 1359.8 1359.4 1359.0 1358.6 1358.2 1357.9 1356.9 1356.5 1356.1 1355.7 1355.3
Pressure drop (kPa) 0.400 0.398 0.400 0.404 0.409 0.295 0.297 0.413 0.409 0.405 0.401
Process HTC (W/m2-K) 1868.2 1870.6 1857.1 1840.2 1823.2 1810.3 1810.2 1823.4 1841.0 1858.5 1872.7
Process reynolds 638755 639992 641141 642061 642733 643141 643409 643818 644489 645410 646561
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.180 0.180 0.252 0.252 0.252 0.252
Cumulative area (m2) 10.344 10.596 10.848 11.099 11.351 11.531 11.711 11.963 12.214 12.466 12.718
Duty (MegaWatts) 0.0106 0.0109 0.0091 0.0069 0.0048 0.0023 0.0023 0.0048 0.0069 0.0090 0.0108
Cumulative duty (MegaWatts) 0.3004 0.3113 0.3204 0.3272 0.3320 0.3343 0.3366 0.3414 0.3483 0.3573 0.3682
Average flux (W/m2) 42118 43159 35973 27292 18936 12886 12883 18923 27270 35932 43099
Maximum flux (W/m2) 65177 68117 57076 43531 30346 20750 20747 30330 43500 57023 68035
Fraction convection (--) 0.1656 0.1652 0.1594 0.1658 0.1672 0.1428 0.1427 0.1670 0.1656 0.1592 0.1649
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 6
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 56 57 58 59 60 61 62 63 64 65 66
Tube number 13 13 13 13 13 12 12 12 12 12 12
Length from tube inlet (m) 35.769 36.470 37.172 37.873 38.380 38.693 39.200 39.901 40.602 41.303 42.004
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 353.54 353.80 354.00 354.16 354.25 354.31 354.41 354.56 354.77 355.02 355.31
Inside wall temperature (C) 378.79 374.00 369.71 366.70 365.48 365.48 366.80 370.07 374.69 379.91 380.78
Outside wall temperature (C) 428.67 413.55 400.22 390.90 387.18 387.18 391.00 400.57 414.22 429.74 431.84
Peak wall temperature (C) 469.75 446.78 426.90 412.36 405.61 405.60 412.46 427.24 447.41 470.76 476.23
Pressure (kPa) 1354.9 1354.5 1354.1 1353.7 1353.4 1352.5 1352.2 1351.8 1351.4 1351.0 1350.6
Pressure drop (kPa) 0.399 0.402 0.406 0.410 0.184 0.185 0.412 0.410 0.407 0.403 0.400
Process HTC (W/m2-K) 1871.1 1855.0 1840.4 1829.9 1826.2 1826.5 1831.3 1842.7 1858.6 1876.0 1878.4
Process reynolds 647802 648901 649763 650437 650855 651095 651513 652187 653049 654150 655396
Area (m2) 0.252 0.252 0.252 0.252 0.112 0.112 0.252 0.252 0.252 0.252 0.252
Cumulative area (m2) 12.969 13.221 13.473 13.725 13.837 13.949 14.201 14.453 14.705 14.956 15.208
Duty (MegaWatts) 0.0106 0.0084 0.0065 0.0051 0.0021 0.0021 0.0051 0.0065 0.0084 0.0106 0.0108
Cumulative duty (MegaWatts) 0.3787 0.3871 0.3936 0.3987 0.4008 0.4029 0.4080 0.4145 0.4229 0.4334 0.4443
Average flux (W/m2) 42039 33346 25728 20415 18302 18302 20412 25715 33324 42004 43042
Maximum flux (W/m2) 65073 51922 40607 32361 28551 28551 32358 40594 51893 65022 67959
Fraction convection (--) 0.1653 0.1547 0.1416 0.1333 0.1459 0.1459 0.1332 0.1415 0.1546 0.1651 0.1646
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 7
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 67 68 69 70 71 72 73 74 75 76 77
Tube number 12 12 12 12 11 11 11 11 11 11 11
Length from tube inlet (m) 42.705 43.406 44.107 44.708 45.210 45.811 46.512 47.213 47.914 48.615 49.316
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 355.58 355.80 355.96 356.05 356.11 356.21 356.37 356.58 356.85 357.14 357.40
Inside wall temperature (C) 376.95 372.15 367.38 363.88 364.00 367.76 372.88 378.16 382.55 382.23 377.46
Outside wall temperature (C) 419.49 404.38 389.71 379.04 379.16 390.07 405.09 420.64 433.55 431.96 416.88
Peak wall temperature (C) 457.10 433.40 410.14 393.14 393.26 410.50 434.09 458.22 477.88 472.92 449.99
Pressure (kPa) 1350.2 1349.8 1349.4 1349.0 1348.0 1347.7 1347.2 1346.8 1346.4 1346.0 1345.6
Pressure drop (kPa) 0.402 0.406 0.411 0.297 0.298 0.416 0.412 0.407 0.403 0.402 0.404
Process HTC (W/m2-K) 1865.0 1848.2 1831.3 1818.6 1818.4 1831.5 1848.9 1866.4 1880.4 1878.8 1862.8
Process reynolds 656553 657477 658152 658562 658830 659241 659916 660842 662001 663249 664356
Area (m2) 0.252 0.252 0.252 0.180 0.180 0.252 0.252 0.252 0.252 0.252 0.252
Cumulative area (m2) 15.460 15.712 15.963 16.143 16.323 16.575 16.827 17.078 17.330 17.582 17.834
Duty (MegaWatts) 0.0090 0.0068 0.0047 0.0023 0.0023 0.0047 0.0068 0.0090 0.0108 0.0106 0.0084
Cumulative duty (MegaWatts) 0.4533 0.4601 0.4649 0.4672 0.4695 0.4742 0.4811 0.4901 0.5009 0.5114 0.5198
Average flux (W/m2) 35859 27182 18829 12788 12785 18819 27160 35819 42985 41925 33238
Maximum flux (W/m2) 56922 43386 30204 20620 20617 30191 43354 56868 67877 64918 51777
Fraction convection (--) 0.1587 0.1649 0.1660 0.1414 0.1413 0.1659 0.1647 0.1585 0.1643 0.1647 0.1541
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 8
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 78 79 80 81 82 83 84 85 86 87 88
Tube number 11 11 11 10 10 10 10 10 10 10 10
Length from tube inlet (m) 50.017 50.718 51.225 51.538 52.045 52.747 53.448 54.149 54.850 55.551 56.252
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 357.60 357.76 357.85 357.91 358.00 358.16 358.36 358.62 358.91 359.18 359.39
Inside wall temperature (C) 373.18 370.18 368.98 368.97 370.28 373.54 378.14 383.33 384.20 380.39 375.60
Outside wall temperature (C) 403.57 394.28 390.56 390.56 394.38 403.92 417.54 433.03 435.13 422.79 407.71
Peak wall temperature (C) 430.15 415.64 408.90 408.90 415.73 430.49 450.62 473.93 479.39 460.28 436.62
Pressure (kPa) 1345.2 1344.8 1344.5 1343.6 1343.3 1342.9 1342.5 1342.1 1341.7 1341.3 1340.9
Pressure drop (kPa) 0.409 0.412 0.185 0.186 0.415 0.413 0.409 0.405 0.403 0.405 0.409
Process HTC (W/m2-K) 1848.3 1837.9 1834.2 1834.5 1839.3 1850.6 1866.3 1883.6 1886.0 1872.6 1856.0
Process reynolds 665224 665902 666321 666561 666980 667656 668525 669634 670888 672051 672981
Area (m2) 0.252 0.252 0.112 0.112 0.252 0.252 0.252 0.252 0.252 0.252 0.252
Cumulative area (m2) 18.085 18.337 18.449 18.562 18.814 19.065 19.317 19.569 19.821 20.072 20.324
Duty (MegaWatts) 0.0065 0.0051 0.0020 0.0020 0.0051 0.0064 0.0084 0.0105 0.0108 0.0090 0.0068
Cumulative duty (MegaWatts) 0.5263 0.5314 0.5334 0.5355 0.5406 0.5470 0.5554 0.5659 0.5768 0.5857 0.5926
Average flux (W/m2) 25627 20321 18207 18207 20318 25614 33216 41891 42929 35746 27071
Maximum flux (W/m2) 40468 32229 28421 28421 32226 40455 51748 64868 67801 56767 43238
Fraction convection (--) 0.1409 0.1324 0.1452 0.1452 0.1324 0.1408 0.1539 0.1645 0.1640 0.1580 0.1640
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 9
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 89 90 91 92 93 94 95 96 97 98 99
Tube number 10 10 9 9 9 9 9 9 9 9 9
Length from tube inlet (m) 56.953 57.554 58.055 58.656 59.357 60.058 60.759 61.460 62.161 62.862 63.563
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 359.55 359.64 359.70 359.80 359.95 360.17 360.43 360.72 360.98 361.18 361.33
Inside wall temperature (C) 370.86 367.37 367.50 371.23 376.33 381.59 385.96 385.64 380.89 376.63 373.65
Outside wall temperature (C) 393.06 382.42 382.54 393.42 408.41 423.95 436.82 435.25 420.19 406.90 397.63
Peak wall temperature (C) 413.40 396.44 396.56 413.75 437.30 461.39 481.02 476.08 453.18 433.38 418.90
Pressure (kPa) 1340.5 1340.1 1339.1 1338.7 1338.3 1337.9 1337.5 1337.1 1336.7 1336.3 1335.9
Pressure drop (kPa) 0.414 0.299 0.300 0.418 0.414 0.409 0.405 0.404 0.407 0.411 0.415
Process HTC (W/m2-K) 1839.2 1826.5 1826.4 1839.3 1856.6 1873.9 1887.8 1886.3 1870.3 1855.9 1845.7
Process reynolds 673659 674071 674340 674752 675430 676360 677525 678782 679897 680769 681449
Area (m2) 0.252 0.180 0.180 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252
Cumulative area (m2) 20.576 20.756 20.936 21.187 21.439 21.691 21.942 22.194 22.446 22.698 22.949
Duty (MegaWatts) 0.0047 0.0023 0.0023 0.0047 0.0068 0.0090 0.0108 0.0105 0.0083 0.0064 0.0051
Cumulative duty (MegaWatts) 0.5973 0.5996 0.6018 0.6066 0.6134 0.6224 0.6331 0.6437 0.6520 0.6584 0.6635
Average flux (W/m2) 18725 12690 12687 18712 27049 35708 42869 41812 33131 25523 20223
Maximum flux (W/m2) 30065 20491 20485 30049 43206 56713 67719 64763 51628 40329 32096
Fraction convection (--) 0.1648 0.1400 0.1399 0.1647 0.1638 0.1577 0.1637 0.1641 0.1534 0.1401 0.1316
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 10
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 100 101 102 103 104 105 106 107 108 109 110
Tube number 9 8 8 8 8 8 8 8 8 8 8
Length from tube inlet (m) 64.071 64.384 64.891 65.592 66.293 66.994 67.695 68.396 69.097 69.798 70.399
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 361.43 361.48 361.58 361.74 361.93 362.19 362.48 362.74 362.96 363.11 363.20
Inside wall temperature (C) 372.45 372.45 373.75 377.00 381.57 386.74 387.61 383.81 379.04 374.32 370.85
Outside wall temperature (C) 393.92 393.92 397.72 407.25 420.85 436.31 438.41 426.08 411.01 396.39 385.78
Peak wall temperature (C) 412.17 412.16 418.99 433.71 453.81 477.08 482.52 463.44 439.82 416.64 399.72
Pressure (kPa) 1335.6 1334.7 1334.4 1334.0 1333.6 1333.1 1332.7 1332.3 1331.9 1331.5 1331.2
Pressure drop (kPa) 0.186 0.187 0.417 0.415 0.412 0.408 0.405 0.407 0.411 0.416 0.300
Process HTC (W/m2-K) 1841.9 1842.3 1846.9 1858.2 1873.7 1890.9 1893.2 1880.0 1863.4 1846.8 1834.2
Process reynolds 681869 682110 682531 683212 684085 685202 686463 687633 688568 689249 689663
Area (m2) 0.112 0.112 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.180
Cumulative area (m2) 23.062 23.174 23.426 23.678 23.929 24.181 24.433 24.685 24.936 25.188 25.368
Duty (MegaWatts) 0.0020 0.0020 0.0051 0.0064 0.0083 0.0105 0.0108 0.0090 0.0068 0.0047 0.0023
Cumulative duty (MegaWatts) 0.6656 0.6676 0.6727 0.6791 0.6874 0.6980 0.7087 0.7177 0.7245 0.7292 0.7314
Average flux (W/m2) 18113 18113 20220 25513 33109 41777 42815 35632 26961 18617 12592
Maximum flux (W/m2) 28289 28289 32093 40317 51600 64716 67643 56612 43089 29923 20359
Fraction convection (--) 0.1445 0.1445 0.1316 0.1401 0.1533 0.1639 0.1635 0.1572 0.1631 0.1636 0.1386
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 11
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 111 112 113 114 115 116 117 118 119 120 121
Tube number 7 7 7 7 7 7 7 7 7 7 6
Length from tube inlet (m) 70.901 71.502 72.203 72.904 73.605 74.306 75.007 75.708 76.409 76.916 77.229
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 363.27 363.36 363.51 363.73 363.99 364.28 364.53 364.73 364.89 364.98 365.04
Inside wall temperature (C) 370.97 374.68 379.76 385.00 389.36 389.04 384.30 380.07 377.09 375.90 375.90
Outside wall temperature (C) 385.90 396.75 411.71 427.22 440.08 438.51 423.48 410.22 400.96 397.27 397.27
Peak wall temperature (C) 399.84 416.99 440.49 464.55 484.15 479.21 456.36 436.59 422.13 415.42 415.42
Pressure (kPa) 1330.2 1329.8 1329.4 1329.0 1328.5 1328.1 1327.7 1327.3 1326.9 1326.6 1325.7
Pressure drop (kPa) 0.302 0.420 0.416 0.412 0.408 0.406 0.409 0.414 0.417 0.188 0.188
Process HTC (W/m2-K) 1834.0 1846.9 1864.0 1881.2 1895.0 1893.5 1877.6 1863.3 1853.1 1849.4 1849.7
Process reynolds 689932 690345 691025 691959 693132 694398 695518 696394 697077 697499 697741
Area (m2) 0.180 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.112 0.112
Cumulative area (m2) 25.548 25.800 26.051 26.303 26.555 26.807 27.058 27.310 27.562 27.674 27.787
Duty (MegaWatts) 0.0023 0.0047 0.0068 0.0090 0.0108 0.0105 0.0083 0.0064 0.0051 0.0020 0.0020
Cumulative duty (MegaWatts) 0.7337 0.7384 0.7452 0.7541 0.7649 0.7754 0.7837 0.7901 0.7952 0.7972 0.7992
Average flux (W/m2) 12589 18608 26939 35594 42755 41698 33024 25421 20125 18021 18021
Maximum flux (W/m2) 20356 29907 43058 56559 67561 64609 51480 40191 31961 28160 28160
Fraction convection (--) 0.1385 0.1635 0.1629 0.1570 0.1631 0.1635 0.1528 0.1394 0.1308 0.1438 0.1438
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 12
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 122 123 124 125 126 127 128 129 130 131 132
Tube number 6 6 6 6 6 6 6 6 6 5 5
Length from tube inlet (m) 77.736 78.437 79.138 79.839 80.541 81.242 81.943 82.644 83.245 83.746 84.347
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 365.13 365.29 365.48 365.74 366.02 366.29 366.50 366.65 366.75 366.81 366.90
Inside wall temperature (C) 377.19 380.43 384.98 390.13 390.99 387.21 382.45 377.75 374.30 374.42 378.11
Outside wall temperature (C) 401.05 410.56 424.13 439.56 441.66 429.34 414.30 399.70 389.12 389.24 400.05
Peak wall temperature (C) 422.22 436.92 456.98 480.22 485.64 466.58 443.00 419.86 402.98 403.09 420.21
Pressure (kPa) 1325.4 1325.0 1324.6 1324.2 1323.8 1323.3 1322.9 1322.5 1322.2 1321.1 1320.8
Pressure drop (kPa) 0.420 0.418 0.414 0.410 0.408 0.409 0.414 0.419 0.302 0.303 0.423
Process HTC (W/m2-K) 1854.3 1865.5 1880.9 1897.9 1900.2 1887.1 1870.6 1854.1 1841.6 1841.5 1854.2
Process reynolds 698164 698848 699727 700849 702116 703294 704235 704919 705333 705601 706014
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.180 0.180 0.252
Cumulative area (m2) 28.038 28.290 28.542 28.794 29.045 29.297 29.549 29.800 29.980 30.160 30.412
Duty (MegaWatts) 0.0051 0.0064 0.0083 0.0105 0.0107 0.0089 0.0068 0.0047 0.0022 0.0022 0.0047
Cumulative duty (MegaWatts) 0.8043 0.8107 0.8190 0.8295 0.8402 0.8492 0.8559 0.8606 0.8628 0.8651 0.8697
Average flux (W/m2) 20122 25412 33002 41660 42698 35519 26851 18513 12498 12495 18501
Maximum flux (W/m2) 31957 40175 51452 64562 67483 56458 42941 29784 20229 20223 29768
Fraction convection (--) 0.1308 0.1393 0.1527 0.1633 0.1629 0.1565 0.1622 0.1624 0.1372 0.1371 0.1623
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 13
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 133 134 135 136 137 138 139 140 141 142 143
Tube number 5 5 5 5 5 5 5 5 4 4 4
Length from tube inlet (m) 85.048 85.749 86.450 87.151 87.852 88.553 89.254 89.761 90.075 90.582 91.283
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 367.05 367.26 367.53 367.81 368.07 368.26 368.42 368.51 368.57 368.66 368.81
Inside wall temperature (C) 383.17 388.39 392.73 392.41 387.70 383.48 380.52 379.33 379.33 380.62 383.84
Outside wall temperature (C) 414.99 430.48 443.32 441.75 426.74 413.51 404.27 400.59 400.59 404.36 413.86
Peak wall temperature (C) 443.67 467.69 487.25 482.34 459.51 439.78 425.35 418.65 418.65 425.44 440.11
Pressure (kPa) 1320.4 1319.9 1319.5 1319.1 1318.7 1318.3 1317.9 1317.6 1316.7 1316.4 1316.0
Pressure drop (kPa) 0.419 0.414 0.410 0.409 0.412 0.416 0.420 0.189 0.189 0.422 0.420
Process HTC (W/m2-K) 1871.2 1888.2 1901.9 1900.4 1884.6 1870.4 1860.3 1856.6 1856.9 1861.5 1872.5
Process reynolds 706697 707637 708818 710091 711216 712097 712783 713208 713450 713875 714563
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.252 0.252 0.112 0.112 0.252 0.252
Cumulative area (m2) 30.664 30.915 31.167 31.419 31.671 31.922 32.174 32.287 32.399 32.651 32.902
Duty (MegaWatts) 0.0068 0.0089 0.0107 0.0105 0.0083 0.0064 0.0050 0.0020 0.0020 0.0050 0.0064
Cumulative duty (MegaWatts) 0.8765 0.8854 0.8962 0.9066 0.9149 0.9213 0.9263 0.9284 0.9304 0.9354 0.9418
Average flux (W/m2) 26828 35481 42639 41585 32913 25321 20027 17926 17926 20024 25311
Maximum flux (W/m2) 42910 56404 67401 64454 51332 40049 31828 28030 28030 31822 40036
Fraction convection (--) 0.1620 0.1563 0.1626 0.1629 0.1521 0.1387 0.1299 0.1431 0.1431 0.1299 0.1386
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 14
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 144 145 146 147 148 149 150 151 152 153 154
Tube number 4 4 4 4 4 4 4 3 3 3 3
Length from tube inlet (m) 91.984 92.685 93.386 94.087 94.788 95.489 96.090 96.591 97.192 97.894 98.595
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 369.01 369.26 369.55 369.81 370.02 370.17 370.27 370.32 370.42 370.57 370.78
Inside wall temperature (C) 388.38 393.50 394.36 390.59 385.85 381.16 377.73 377.85 381.53 386.56 391.76
Outside wall temperature (C) 427.40 442.80 444.89 432.59 417.57 402.99 392.43 392.55 403.34 418.25 433.72
Peak wall temperature (C) 460.13 483.33 488.75 469.71 446.16 423.06 406.21 406.32 423.40 446.82 470.81
Pressure (kPa) 1315.5 1315.1 1314.7 1314.3 1313.9 1313.5 1313.1 1312.1 1311.7 1311.3 1310.9
Pressure drop (kPa) 0.417 0.412 0.410 0.412 0.416 0.421 0.304 0.305 0.425 0.421 0.417
Process HTC (W/m2-K) 1887.8 1904.7 1907.0 1893.9 1877.5 1861.1 1848.8 1848.6 1861.2 1878.1 1895.0
Process reynolds 715444 716571 717848 719033 719977 720663 721077 721346 721760 722446 723391
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.252 0.180 0.180 0.252 0.252 0.252
Cumulative area (m2) 33.154 33.406 33.658 33.909 34.161 34.413 34.593 34.773 35.024 35.276 35.528
Duty (MegaWatts) 0.0083 0.0105 0.0107 0.0089 0.0067 0.0046 0.0022 0.0022 0.0046 0.0067 0.0089
Cumulative duty (MegaWatts) 0.9501 0.9605 0.9712 0.9802 0.9869 0.9915 0.9937 0.9960 1.0006 1.0073 1.0162
Average flux (W/m2) 32895 41547 42585 35409 26740 18406 12400 12397 18396 26718 35368
Maximum flux (W/m2) 51304 64407 67325 56303 42790 29642 20097 20091 29626 42758 56250
Fraction convection (--) 0.1520 0.1627 0.1623 0.1558 0.1613 0.1613 0.1358 0.1357 0.1611 0.1611 0.1555
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 15
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 155 156 157 158 159 160 161 162 163 164 165
Tube number 3 3 3 3 3 3 2 2 2 2 2
Length from tube inlet (m) 99.296 99.997 100.70 101.40 102.10 102.61 102.92 103.43 104.13 104.83 105.53
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 371.04 371.33 371.58 371.77 371.92 372.02 372.07 372.17 372.32 372.51 372.76
Inside wall temperature (C) 396.09 395.77 391.07 386.87 383.92 382.74 382.74 384.02 387.23 391.75 396.86
Outside wall temperature (C) 446.55 444.97 429.99 416.79 407.56 403.89 403.89 407.65 417.13 430.64 446.02
Peak wall temperature (C) 490.35 485.44 462.66 442.96 428.55 421.86 421.86 428.64 443.28 463.27 486.43
Pressure (kPa) 1310.5 1310.1 1309.6 1309.2 1308.8 1308.5 1307.6 1307.3 1306.9 1306.5 1306.0
Pressure drop (kPa) 0.413 0.411 0.414 0.419 0.422 0.190 0.190 0.424 0.422 0.419 0.415
Process HTC (W/m2-K) 1908.6 1907.0 1891.4 1877.3 1867.2 1863.5 1863.8 1868.4 1879.3 1894.5 1911.2
Process reynolds 724578 725857 726989 727874 728563 728990 729233 729660 730348 731233 732367
Area (m2) 0.252 0.252 0.252 0.252 0.252 0.112 0.112 0.252 0.252 0.252 0.252
Cumulative area (m2) 35.780 36.031 36.283 36.535 36.786 36.899 37.011 37.263 37.515 37.766 38.018
Duty (MegaWatts) 0.0107 0.0104 0.0083 0.0063 0.0050 0.0020 0.0020 0.0050 0.0063 0.0083 0.0104
Cumulative duty (MegaWatts) 1.0269 1.0374 1.0456 1.0520 1.0570 1.0590 1.0610 1.0660 1.0724 1.0806 1.0911
Average flux (W/m2) 42525 41468 32806 25219 19930 17832 17832 19927 25210 32787 41433
Maximum flux (W/m2) 67243 64300 51187 39910 31693 27898 27898 31689 39894 51155 64249
Fraction convection (--) 0.1620 0.1623 0.1515 0.1379 0.1291 0.1424 0.1424 0.1291 0.1379 0.1514 0.1622
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 16
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 166 167 168 169 170 171 172 173 174 175 176
Tube number 2 2 2 2 2 1 1 1 1 1 1
Length from tube inlet (m) 106.23 106.93 107.63 108.33 108.94 109.44 110.04 110.74 111.44 112.14 112.84
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 373.05 373.31 373.52 373.67 373.76 373.82 373.91 374.06 374.27 374.53 374.82
Inside wall temperature (C) 397.71 393.95 389.23 384.56 381.14 381.26 384.92 389.93 395.11 399.43 399.11
Outside wall temperature (C) 448.10 435.82 420.81 406.26 395.73 395.84 406.61 421.49 436.94 449.75 448.18
Peak wall temperature (C) 491.83 472.83 449.30 426.25 409.43 409.54 426.58 449.96 473.91 493.43 488.54
Pressure (kPa) 1305.6 1305.2 1304.8 1304.4 1304.0 1303.0 1302.6 1302.2 1301.8 1301.4 1300.9
Pressure drop (kPa) 0.413 0.414 0.419 0.423 0.306 0.307 0.428 0.424 0.419 0.415 0.414
Process HTC (W/m2-K) 1913.5 1900.5 1884.2 1867.9 1855.7 1855.5 1868.0 1884.7 1901.5 1915.0 1913.4
Process reynolds 733652 734843 735791 736479 736894 737163 737578 738267 739217 740409 741694
Area (m2) 0.252 0.252 0.252 0.252 0.180 0.180 0.252 0.252 0.252 0.252 0.252
Cumulative area (m2) 38.270 38.522 38.773 39.025 39.205 39.385 39.637 39.888 40.140 40.392 40.644
Duty (MegaWatts) 0.0107 0.0089 0.0067 0.0046 0.0022 0.0022 0.0046 0.0067 0.0089 0.0107 0.0104
Cumulative duty (MegaWatts) 1.1017 1.1106 1.1173 1.1219 1.1242 1.1264 1.1310 1.1377 1.1465 1.1572 1.1676
Average flux (W/m2) 42468 35295 26630 18302 12302 12299 18289 26607 35254 42408 41354
Maximum flux (W/m2) 67164 56149 42642 29500 19964 19961 29484 42610 56095 67082 64145
Fraction convection (--) 0.1617 0.1550 0.1603 0.1600 0.1343 0.1343 0.1599 0.1601 0.1548 0.1614 0.1618
Boiling flow regime (--) Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri


Firebox Monitor (Cylindrical Heater) Page 17
Released
Releasedto
tothe
thefollowing
followingHTRI
HTRIMember
MemberCompany:
Company:

AHMM
AHMM
Xfh 7.3.2 1/15/2023 16:39 SN: 46639-9796905050 SI Units
FH Standard Testcase 5
Standalone Cylindrical Heater

Process Fluid
Point number 177 178 179 180
Tube number 1 1 1 1
Length from tube inlet (m) 113.54 114.24 114.94 115.45
Mass fraction vapor (--) 0.0000 0.0000 0.0000 0.0000
Process temperature (C) 375.06 375.26 375.41 375.50
Inside wall temperature (C) 394.43 390.25 387.31 386.13
Outside wall temperature (C) 433.22 420.04 410.83 407.16
Peak wall temperature (C) 465.77 446.11 431.73 425.05
Pressure (kPa) 1300.5 1300.1 1299.7 1299.4
Pressure drop (kPa) 0.417 0.421 0.425 0.191
Process HTC (W/m2-K) 1897.9 1883.9 1873.8 1870.2
Process reynolds 742833 743722 744415 744842
Area (m2) 0.252 0.252 0.252 0.112
Cumulative area (m2) 40.895 41.147 41.399 41.511
Duty (MegaWatts) 0.0082 0.0063 0.0050 0.0020
Cumulative duty (MegaWatts) 1.1759 1.1822 1.1872 1.1892
Average flux (W/m2) 32699 25119 19832 17734
Maximum flux (W/m2) 51035 39768 31557 27765
Fraction convection (--) 0.1508 0.1372 0.1283 0.1417
Boiling flow regime (--) Liquid Liquid Liquid Liquid

C:\Program Files (x86)\HTRI\XchangerSuite7-Hon\Samples\Xfh_Sample.htri