‘SmartAX MAS6Q0T/MAS603T/MAS6O8T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning Monitoring Solution Cabinet Type Typical Configuration ETP4830 Monitoring FO1S300 ‘One MAS603T shelf Solution ETP4890 Monitoring FOIDS00 ‘One MAS600T(MAS603T) Solution shelf Power3000 Monitoring, - Use this program when you Solution need to monitor the extemal power supply Power 3000 Heat Exchanger Monitoring | - Heat Exchanger Solution Fan Tray Monitoring - Fan Tray Solution Commissioning the EMU_ESC This topic describes how to commission the H801ESC board to ensure that it monitors the environmental conditions of the device according to the actual conditions, Context ESC stands for the environment and power monitoring board. The H801ESC board monitors environment parameters such as temperature, humidity, smoke, water, fire, voltage, and power supply through various sensors. ‘When commissioning the H801ESC board, pay attention to the following points: © The EMU sub-nodes are numbered from 0 to 31 © When the system is configured with multiple EMUs simultaneously, make sure that the sub-nodes do not conflict with each other. ‘Table 1-23 lists the default configuration of the H801ESC board, Table 1-23 Default configuration of the H801ESC board Parameter Default Value Sub-node 15 Issue 02 (2013-07-25) Huawei Proprictary and Confidential Mi Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6QOT/MAS603T/MAS608T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning Procedure Step1 Step2 Parameter Default Value Analog parameters | ESC analog parameter IDs: ‘© 0: allocated to the board temperature sensor by default (unable to be changed by the user). © 1-4: allocated to the voltage sensor by default. = | indicates ~48 V input of channel 0. = 2 indica es -48 V input of channel 1 = 3 indicates ~48 V input of channel 2. = 4 indicates -48 V input of channel 3. ® 5.8: user-defined analog parameters allocated to other extended analog sensors, such as the temperature sensor and the humidity ‘Upper and lower alarm thresholds ‘© Temperature: $°C to 55°C © Humidity: 0% RH to 80% RH Digital parameters | ESC digital parameter IDs © Allocated by default (unable to be changed by the user) = 0: MDF = 1: door status sensor 0 = 9: water = 10-13: lightning arresters 0-3 = 14-15: switehes 11 and 12 = 16-17: switches 21 and 22 = 18-19: switches 31 and 32 = 20-21: switehes 41 and 42 = 22: extemal sensor power © User-defined IDs = 2.8: allocated to other extended digital sensors. Set the DIP switch of the sub-node for the H801ESC board. By default, the sub-node ID is 15. ‘The H801ESC board communicates with the MAS600T/MA603T/MAS608T in the master node and sub-node mode. Therefore, the DIP switch of the sub-node for the H801ESC board must be consistent with that for the MAS6OOT/MAS603T/MAS608T. For details about how to configure the DIP switches of the H801ESC board, see the Description of DIP Switches in Checking the Settings of DIP Switches on the H801ESC Board, Insert the H801ESC board into the corresponding slot of the PDU, and make sure that the MAS6001T/MAS603T/MAS608T and the H801ESC board are connected through the RS-485 serial port cable, Issue 02 (2013-07-25) Huawei Proprietary and Confidential 5 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6QOT/MAS603T/MAS608T Multi-service ‘Access Module Commissioning and Configuration Guide L Commissioning Step 3 Step 4 Step 5 When the device is delivered, the H801ESC board is correctly connected to the shelf. The connection need not be changed for the device commissioning. The COM2 of the H801ESC board is connected to the ESC of the MAS600T/MAS603T/MAS6ORT, In this case, the HBO1ESC collects and reports the environment information to the control board, Run the emu add command to add an H801ESC board. By default, the sub-node ID is 15, Run the interface emu command to enter the H801ESC mode. Run the ese analog command to configure the ESC analog parameters, By default, the upper and lower alarm thresholds of the temperature are 55°C and $°C respectively; the upper and lower alarm thresholds of the humidity are 80% RH and 0% RH respectively, Step 6 Run the ese digital command to set the ESC digital parameters, Step 7 Run the save command to save the data. —End Result © In step 2, you can confirm that the RUN ALM LED on the H801ESC board is orange and blinks repeatedly once in every 300 ms, which indicates that the board is registering, © After a while, the RUN ALM LED on the H801ESC board turns orange and is on for Is and off for Is repeatedly, which indicates that an alarm is generated, Certain EMU parameters have the initial configurations (namely, default alarm thresholds); therefore, if any parameter reaches the threshold, an alarm is generated. © After the configuration, the RUN ALM LED on the H801ESC board turns green and is on for Is and off for Is repeatedly, which indicates that the H&01ESC board monitors the environment normally. © Inti H801ESC mode, run the display ese system parameter command to check whether the ESC information is the same as the data plan. © Close doors of the cabinet, and query alarms. Ensure that no alarm of the monitoring parameters is generated. Example Add an H801ESC board, set the analog and digital parameters of the H801ESC board, and save the data, To set the ESC analog parameters (set the user-defined analog parameter ID to 5, upper alarm threshold to 70, lower alarm threshold to -30, analog parameter name to Temperature_1 with the unit of C) and the ESC digital parameters (set the user-defined digital parameter [D to 7, set the door status alarm whose ID is 8, set the alarm name to Door_! and the available level of the alarm to high level), do as follows: buawei (config) ¥emu add 1 H6OLESC 0 15 NeOIESC rnawei (config) #interface ems 1 dewes (configif-nfOless~r) ¥ege analog 5 alacm-uppes-Linit 70 alarn-lower-limit =30 nane Teaperature 1 unit C buswes (config-if-n0less~:) Feac digital 7 digital-alam @ name Door_1 available- puswe! (cont ig-if-n80iese~2) fdLgptay ese systen paraneter ruawei (config-#-nd0lesc~!) FqUL, ones (config) #eave Issue 02 (2013-07-25) Huawei Proprietary and Confidential 86 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6Q0T/MAS603T/MAS6O8T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning Configuring H801VESC Environment Monitoring Parameters This topic describes how to configure environment monitoring parameters of the H801VESC_ board by using the CLL Mapping Between Monitoring Parameters and Device Ports The monitoring parameters displayed on the device map those defined for the ALM ports of the H801VESC board. CO note Before adding a user-defined digital parameter, make sure thatthe port corresponding to this parameter is connected with an environment monitoring cable. Configuration Process The monitoring parameters can be reported to the control board only when the data of the H801VESC board is correctly configured in the system. Table 1-24 Commands for configuring the H801VESC environment monitoring parameters Operation ‘Command ‘Add an EMU, emu add Confirm the EMU status display emu Query the default monitoring | display vese system parameter information Add digital monitoring parameters | vese digital Configure the control output vese control out Query the control output isplay control out Verify that the monitoring display vese envinronment info parameters are normal CO nore For details about the command parameters related to the configuration operations listed in the preceding table, see the Command Reference, The following describes how to configure data associated with H801VESC environment monitoring. 1, Log in to control board by using a maintenance terminal and add an EMU. hnoawei (config) 4emu add 0 HBOIVESC 0 25 HeOIVESC 2. Query the status of the H801VESC board, nuawel (contig) #dieplay emu 0 3. Enter the H801VESC configuration mode and query the default digital parameters. huawei (config) #interface em 0 Issue 02 (2013-07-25) Huawei Proprictary and Confidential 7 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS600T/MAS603T/MAS608T Multiservice ‘Access Module Commissioning and Configuration Guide 0} #display vese system paraneter According to the query result, the digital parameters are not configured, 4. Configure the digital parameters, nuawel (config~I#-n801vesc-0) 4veae digital 0 available-level high-Les alam @ nane Door note © availuble-tevel indicates the valid level of the dita parameter. Ite level of the digit does not equals tothe valid level, an alarm is generated, Otherwise the digit sensor does not report any alarm, {© ow-evel indicates thatthe vali levels low level, and high-level indicates that the valid level is @high level. Inthe system CL, 0 indicates the low level and I indicates the high level © To set the valid level to low level, use parameter low-level; to set the valid leet to high level use parameter high-level. © Using the door stats as an example, the low level is valid, When the eabinet door is open, the level ofthe digit is hig level. This hig level isnot the valid level and therefore an alan is generated © digitatatarm is used to associate the configured digital parameter witha known alarm index. ‘The value range ofthis parameter is 1-22, For details about the indications of these values, see Table 1-26, ‘Table 1-25 Value range of digital-alarm Index | Alarm Index | Alarm Index | Alarm 1 AC voltage |] 9 Door 7 Diesel 2 ACswitch |} 10 Thief 18 Odor 3 Battery " Thiet 19 Airecondition voltage 4 Battery fuse |) 12 Wiring 20 Antester s Load fuse |f 13 Fan 21 Switeh 6 Rectifier 14 Fire 2 Hard-fault 7 DCpower | 15 Smoke 8 Door 16 Water 5. Configure the control output ‘Table 1-26 Parameter of Digital Parameter Output on the ALM port Digital Parameter Digital Parameter Output Output on the ALM port (Set on the CLI) ON ‘The output status of the VESC board is fixed at open cireuit Issue 02 (2013-07-25) Huawei Proprietary and Confidential 8 Copyright © Huawei Technologies Co,, Lt. ‘SmartAX MAS6QOT/MAS603T/MAS608T Multiservice ‘Access Module Commissioning and Configuration Guide L Commissioning Digital Parameter Digital Parameter Output Output on the ALM port (Set on the CLI) OFF ‘The output status of the VESC board is fixed at short cireuit nuawel {config~Lf=11801vese-0) tveRe contol out 0 name air-condition on 6. Query the control output. 7. Query the environment information. Ensure that the environment monitoring functions are normal. (OD note “The door status alarm "Door" is generated because the cabinet door is open. 8. Save the data. noawei (cont igeit-aa Configuring the Environment Monitoring Parameters of the EPS30-4815AF This topie describes how to configure the environment monitoring parameters ofthe EPS30-4815AF through the CLL. Mapping Between Monitoring Parameters and Device Ports ‘Table 1-27 describes the mapping between the monitoring parameters displayed on the sensor transfer box. ‘Table 1-27 Mapping between the monitoring parameters displayed on the host and the ports on the sensor transfer box Monitoring Parameter Displayed on the _| Device Port Host Temperature TEM-HU Humidity TEM-HU Digital 0 sTD1 igital 1 s7D2 Digital 2 JTD3 Digital 3 sTD4 igital 4 sTDs Digital 5 sTD6 Issue 02 (2013-07-25) Huawei Proprictary and Confidential wo Copyright © Huawei Technologies Co,, Lt.

You might also like