Dario Daniel Jimenez 2016-12-07 A

L19.Q3_Swap DUL20 to BB5216 Procedure

© Ericsson 2019

All rights reserved. The information in this document is the property of Ericsson. Except as
specifically authorized in writing by Ericsson, the receiver of this document shall keep the
information contained herein confidential and shall protect the same in whole or in part from
disclosure and dissemination to third parties. Disclosure and disseminations to the receiver's
employees shall only be made on a strict need to know basis. The information in this document
is subject to change without notice and Ericsson assumes no responsibility for factual
inaccuracies or typographical errors.
Ericsson Internal
2 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

1 Contents

1 Contents ............................................................................................ 2
2 Revisions ........................................................................................... 2
3 Introduction ....................................................................................... 3
4 Requirements .................................................................................... 3
5 DUL20: Backup CV to be transferred on the new BB5216 (On Site) .. 3
5.1 Connecting Clients ............................................................................ 4
5.2 Create a CV to backup ...................................................................... 5
5.2.1 DUL20 FTP Security mode OFF (On Site) ......................................... 6
5.2.2 DUL20 Backup CV ............................................................................ 8
6 Physically change the DUL20 for the BB 5216 (On Site) ................... 9
6.1.1 DUL20 in RBS 6101 with RRUs and optical fibers ............................. 9
6.1.2 DUL20 in RBS 6101 with RRUs and optical fibers ........................... 11
6.1.3 DUL20 in RBS 6601 inside Tx cabinet. ............................................ 14
7 BB5216: Verify Basic Package (On Site) ......................................... 15
8 BB5216: SW Upgrade (On Site) ...................................................... 15
9 BB5216: Restore CV (On Site) ........................................................ 15
10 BB5216 Final Restart ...................................................................... 15
11 BB5216: License Installation (Remote) ............................................ 16
12 BB5216: Final Verifications (Remote) .............................................. 16

2 Revisions

Rev Data Comments Prepared


A 2019/10/14 Rev.A timalrt
Ericsson Internal
3 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

3 Introduction
This document describes how to swap DUL20 with new BB5216. Take into
consideration that this activity impacts ongoing traffic.

Swap Procedure Step by step

1) DUL20: Verify SW release on existing DUL20 (On Site) and eventually


proceed with SW Upgrade

2) DUL20: Backup CV to be transferred on new BB5216 (On Site)

3) Physically change the DUL20 with the BB 5216 in the same position

4) BB5216: Upgrade to L19.Q3 (On Site)

5) BB5216: Restore CV (On Site)

6) License Installation (Remote)

4 Requirements
• Before reaching the site: L19.Q3 has to be downloaded to the
local PC using E/// vpn.

• FTP server (i.e. FileZilla Server)

• FTP client (i.e. FileZilla Client)

• Putty

• RBS Element Manager

• Serial Cable

• Ethernet Cable

• LMT splitter cable (LTY 151 1018/1)

5 DUL20: Backup CV to be transferred on the new BB5216


(On Site)
Review information with the solution architect.
Ericsson Internal
4 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

5.1 Connecting Clients

To prepare the client computer for the on-site activity, do the following:

1 Using Ethernet cable, connect the client computer to the Fast Ethernet
port (LMTB) of the DUL20.

2 To ensure eNodeB connectivity with Element Manager PC it is necessary


to change PC Local Area Network IP address to belong to the same sub-
network as the eNodeB.

Fig.1

3 In order to avoid EMAS connectivity issues, it is recommended to stop


Symantec (Symantec Endpoint Protection → Change Settings →
Current Location=Out of Ericsson Premises. Then Symantec
Endpoint Protection→ Status → Options →Disable Network Threat
Protection)

4 Start EMAS

5 Enter the local RBS O&M IP address as requested. The IP address is


169.254.1.10 then click Connect
Ericsson Internal
5 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Fig.2

5.2 Create a CV to backup

• From Drop Down Menu select Upgrade and Backup, On the right
panel select CV Tab and click Create CV

Fig.3

• Insert ConfigurationVersionName (es. Backup_DUL), fill at least the


type field and click Execute button.
Ericsson Internal
6 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Fig.4

5.2.1 DUL20 FTP Security mode OFF (On Site)

Before starting the procedure is necessary to set DUL20 security mode to


OFF. Open a telnet session to the node using Putty.
Ericsson Internal
7 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Fig.5

Insert username: rbs and password: rbs

Set eNodeB security mode to OFF: secmode -fu

Fig.6
Ericsson Internal
8 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

5.2.2 DUL20 Backup CV

• Start FTP Server (es. Filezilla Server)

• Using RBS Element Manager, from Drop Down Menu select Upgrade
and Backup, On the right panel select CV Tab, right click on the
previous created CV (es. Backup_DUL), then select Put to FTP.

Fig.7

• Fill in all the requested info:

- cvName: Backup_DUL
-
- pathOnFtpServer: /

- cvBackupNameOnFtpServer: Backup_DUL

- ftpServerIPAddress: 169.254.1.11

- ftpServerUserId: ericsson

- ftpServerPassword: ericsson
Ericsson Internal
9 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Fig.8

• Click Execute.

• Wait until this action will be successfully completed and click Close.

6 Physically change the DUL20 for the BB 5216 (On Site)


Physically change the DUL20 with the BB 5216 in the same position. There
are 3 options of DUL20 on site:

• DUL20 in RBS 6101 with RRUs and optical fibers

• DUL20 on RBS 6101 with radios and feeder

• DUL20 in RBS 6601 inside Tx cabinet.

6.1.1 DUL20 in RBS 6101 with RRUs and optical fibers

Physically change the DUL20 with the BB 5216 in the same position
Ericsson Internal
10 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Install the RPM777193 / 01500 power cable using the same position in the
PDU on the same RBS 6101.
Ericsson Internal
11 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Install the RPM77701/01200 signal cable using the same position in the TCU
on the same RBS 6101.

Connect the 3 optical fibers of the 3 RRUs in the same position.

If necessary, change the TSR432151 / 2000 ethernet cable using the same
position on the Carrier Ethernet IP port.

6.1.2 DUL20 in RBS 6101 with RRUs and optical fibers

Physically change the DUL20 with the BB 5216 in the same position
Ericsson Internal
12 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Install the RPM777193 / 01500 power cable using the same position in the
PDU on the same RBS 6101.

Install the RPM77701/01200 signal cable using the same position in the TCU
on the same RBS 6101.
Ericsson Internal
13 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

Connect the cables of the Radios in the same position.

If necessary, change the TSR432151 / 2000 ethernet cable using the same
position on the Carrier Ethernet IP port.
Ericsson Internal
14 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

6.1.3 DUL20 in RBS 6601 inside Tx cabinet.

Physically change the DUL20 with the BB 5216 in the same position

In this option the same power cable from the RBS 6601 to the site breaker is
used.
Ericsson Internal
15 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

In this option no external signal cable is required in the RBS 6601.

Connect the cables of the RRUs in the same position.

If necessary, change the TSR432151 / 2000 ethernet cable using the same
position on the Carrier Ethernet IP port.

7 BB5216: Verify Basic Package (On Site)


Upgrade BB5216 to L19.Q3 (On Site).

Verify if the basic package is the correct one: otherwise BB5216 Format with
New Basic Package Loading Procedure is needed.

8 BB5216: SW Upgrade (On Site)


Upgrade BB5216 to L19.Q3 (On Site).

9 BB5216: Restore CV (On Site)


Review information with the solution architect.

10 BB5216 Final Restart


Review information with the solution architect.
Ericsson Internal
16 (16)
Prepared (Subject resp) No.

Alejandro Rangel Tovar 1531-FCMC 101 427 Uen

Approved (Document resp) Checked Date Rev Reference

Dario Daniel Jimenez 2016-12-07 A

11 BB5216: License Installation (Remote)


Review information with the solution architect.

12 BB5216: Final Verifications (Remote)


Review information with the solution architect.