MODEL CSH-83/84
The paper used in this manual
is elemental chlorine free.
9-52 Ashihara-cho,
Nishinomiya 662-8580, JAPAN
Telephone : 0798-65-2111
Fax : 0798-65-4200
*IME13090H30*
*IME13090H30*
*IME13090H30*
SAFETY INSTRUCTIONS
WARNING WARNING
Do not open the cover Install the specified transducer tank
unless totally familiar with in accordance with the installation
electrical circuits and instructions. If a different tank is to be
service manual. installed the shipyard is solely respon-
sible for its installation, and it should
High voltage exists inside the be installed so the hull will not be
equipment, and a residual damaged if the tank strikes an object.
charge remains in capacitors
several minutes after the The tank or hull may be damaged if the
power is turned off. Improper tank strikes an object.
handling can result in electri-
cal shock. If a steel tank is installed on a wooden
or FRP vessel, take appropriate
Turn off the power at the switchboard measures to prevent electrolytic
before beginning the installation. corrosion.
Fire or electrical shock can result if the Electrolytic corrosion can damage the
power is left on. hull.
Do not install the equipment where it Be sure that the power supply is
may get wet from rain or water splash. compatible with the voltage rating of
the equipment.
Water in the equipment can result in fire,
electrical shock or equipment damage. Connection of an incorrect power supply
can cause fire or equipment damage. The
Be sure no water leaks in at the trans- voltage rating of the equipment appears
ducer installation site. on the label above the power connector.
Water leakage can sink the vessel. Also
confirm that the transducer will not loosen
by ship’s vibration. The installer of the
equipment is solely responsible for the CAUTION
proper installation of the equipment.
FURUNO will assume no responsibility for Ground the equipment to
any damage associated with improper prevent electrical shock and
installation. mutual interference.
Display unit
for CSH-84 1.7 m 1.3 m
Processor
unit 1.70 m 1.05 m
i
TABLE OF CONTENTS
4. WIRING
4.1 Cable Configuration ...................................................................................................4-1
4.2 How to Use the Crimping Tool and Pin Extractor ..................................................... 4-2
4.3 Location of Connectors ..............................................................................................4-3
4.4 Cable Fabrication and Connector Assembling in Display and Interface Units ..........4-4
4.5 Cable Fabrication and Connector Assembling in Power Unit .................................... 4-7
4.6 Cable Fabrication and Connector Assembling in Transmitter Unit ...........................4-9
4.7 Cable Fabrication and Connector Assembling in Hull Unit (incl. receiver unit) ..... 4-11
4.8 Connection of Transducer Cables ............................................................................4-13
4.9 Connection of Interface Unit ....................................................................................4-14
4.10 Connection of Sub-Display Unit (option) ..............................................................4-19
4.11 Connection of Remote Display Unit (option) ........................................................4-20
4.12 Synchronizing Transmission with Other Sonars or Echo Sounders .......................4-21
4.13 Interlocking Operation with Other Sonars .............................................................4-22
ii
7. ADJUSTMENT AND CHECK
7.1 Hull Unit Check .................................................................................................... 7-1
7.2 Heading Adjustment............................................................................................. 7-2
7.3 DIP Switch Setting in the Display Unit.................................................................. 7-3
7.4 Setting and Adjustment in the Interface Unit......................................................... 7-5
iii
This page is intentionally left blank.
1. SYSTEM CONFIGURATION
STANDARD OPTION
MONITOR (MU-151C)
REMOTE CONTROL BOX DISPLAY UNIT or SUB DISPLAY *
CSH-116 CSH-830 (CSH-83) PROCESSOR UNIT * COMMERCIAL MONITOR CSH-236 * : CSH-83 only
CSH-8400 (CSH-84) CSH-835
or
SHIP'S MAINS
100 VAC, 1φ,
SHIP'S MAINS 50/60 Hz
100 VAC, 1φ,
50/60 Hz
TRANSMITTER UNIT
CSH-810
SPEED LOG
AD CONVERTER
POWER RECEIVER UNIT NAVIGATOR
SUPPLY UNIT CSH-820 CURRENT INDICATOR
CSH-880
COLOR VIDEO SOUNDER
VI-1100A
INTERFACE UNIT
HULL UNIT
CSH-81080 (800 mm stroke)
CSH-81120 (1200 mm stroke)
1-1
2. EQUIPMENT LISTS
Standard Supply
Name Type Qty Remarks
Display Unit CSH-830 Select For CSH-83
CSH-8400 one For CSH-84
Processor Unit CSH-835 Blackbox type for CSH-83
Transmitter Unit CSH-810 1
Receiver Unit CSH-820 1 w/hull unit
Hull Unit CSH-81080 1 stroke 800mm
CSH-81120 stroke 1200mm
Power Unit CSH-880 1
Remote Control Box CSH-116 1
Interface Unit CS-120A 1
Installation Materials CP10-03000 1 set CP10-03010 For CSH-83
6 pair cable
CP10-03600 1 set CP10-03610 For CSH-84
6 pair cable
CP10-06600 1 set CP10-06610 For processor unit
6 pair cable
Accessories FP10-02400 1 set FP10-01801 For CSH-83
FP10-01201
FP10-01203
Nylon cover
RAM card
FP10-01900 1 set FP10-01201 For CSH-84
FP10-01203
FP10-01901
Nylon cover
RAM card
FP10-03000 1 set FP10-01203 For processor unit
RAM card
Spare Parts SP10-02000 1 set For CSH-83/84
SP10-03600 1 set For processor unit
2-1
Optional Equipment
Optional Tools
2-2
3. MOUNTING THE EQUIPMENT
1/3 1/2
Within 600 mm
• Select a place where the hull bottom is flat and the draft is sufficiently deep. Normally, the
transducer should protrude at least 500 mm beyond the keel to minimize the effect of air
foam and bubbles.
• Select a place where interference from other equipment is minimal. Locate the hull unit at
least 2.5 m away from the transducers of other equipment.
• No obstacle should be in the fore direction since it causes a shadow zone and aerated water,
resulting in poor sonar performance.
• Secure sufficient space for wiring and maintenance. Refer to the hull unit outline drawing
for recommended wiring and maintenance space.
• If the ambient temperature of the hull unit is below 0°C, provide the sonar compartment with
a heater to keep the temperature above 0°C.
3-1
Heater
Heat insulator
3-2
Shortening the retraction tank
The retraction tank is 900 mm in length when supplied. Shorten the tank as necessary so that the
transducer is placed well below the keel when it is lowered. The following table provides guide-
lines for shortening the tank. Refer also to the retraction tank installation drawing at the back of
this manual.
Installation
Method
D D
XDCR Travel
800 mm Remove 0 to Same as left Remove 0 to Same as left
35 mm from 35 mm from
bottom. bottom.
Length D must
be less than
1150 mm.
1200 mm Remove 0 to Same as left Remove 0 to Same as left
35 mm from 35 mm from
bottom. bottom.
Length D must
be less than
1350 mm.
Note: When 35 mm is removed and “D” is minimum, the effect of air foam is minimized when
the transducer is fully protruding in water.
3-3
Remarks on installation of retraction tank
• If possible, the installation location should be of double bottom structure.
• If possible, install the tank on the keel, where the tank can be most firmly fixed.
• Install the reinforcement rib as near as possible to the top of the retraction tank, allowing
space for tightening bolts and nuts.
Retraction tank
Reinforcement rib
250–300 mm
• When an attachment flange is used, install reinforcement ribs to the attachment flange.
Attachment flange
250–300 mm
• Add a doubling plate where the retraction tank is welded to the hull bottom. The size of the
doubling plate is normally 1200 to 1300 mm in diameter so it lies across two bottom frames.
3-4
Installing hull unit on retraction tank
After welding the retraction tank and allowing sufficient time for cooling, install the hull unit as
follows:
1. Clean the O-ring and O-ring groove and coat them with a slight amount of grease. Place the
O-ring in position on the tank flange.
2. Lay the gasket (1) on the top of the tank flange.
3. Orient the hull unit so that the arrow on its flange points toward the ship’s bow.
4. 7 of the 16 bolt holes on the hull unit flange have already been fitted with bolts. Insert the
gasket (2) into the bolt holes of the tank flange to which these seven bolts are fitted. Note
that it is difficult to fit them after the hull unit has been placed on the tank.
5. Confirm that the O-ring and the gasket (1) are in position. Place the hull unit on the tank.
6. Coat every bolt, washer and nut with slight amount of grease to ease removal. Fit the insu-
lation gasket (2) into the bolt holes of both the tank and hull unit flanges. Fasten the hull unit
to the retraction tank with gasket (2), flat washers, spring washers and hex bolts.
7. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two
eye bolts at the top of the hull unit, referring to figure at the top of the next page.
Hex Nut
Hex Bolt Flat Washer
Flat Washer
Gasket (2)*
Gasket (2)*
Insulation Gasket (2) * Gasket (1)
Insulation Gasket (2)*
Hull Unit Flange
Gasket (2)*
Gasket (1) Flat Washer
Spring Washer
O-ring Hex Nut
Tank Flange
Insulation Gasket (2)* * Used only on 1200 mm
Gasket (2)* travel type.
Flat Washer
Spring Washer
Hex Nut
3-5
Installing stays (anti-vibration measure)
Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron with
a size of 75 x 75 x 9 mm or more and at least two pieces should be used; one each to ship’s bow
and stern directions. If possible, install two more stays in ship’s transverse direction.
Stay
Stay
Hull Unit
Do not install the stays vertically as shown below. Vibration-resistance effect is reduced since
vibration is applied to the stays as rotation force. Install them horizontally.
Crossbeam
on ceiling
Stay
Eye bolt
Proper installation
Hull 90°
Unit
45°
45°
M10 bolt
Steel washer
Flat washer
Steel washer
Nut
3-7
3.3 Mounting the Transmitter Unit
The transmitter unit can be mounted with or without mounting legs. For use without mounting
legs remove them and use inside mounting holes.
Reinforce the transmitter unit against vibration by stays extending from the eyebolts on the top
of the unit.
Attach stay to
this eye bolt.
3-8
3.7 Grounding the Equipment
Ground all units with a suitable copper strap or ground wire. The location of the ground termi-
nal on each unit is shown below.
CAUTION
Ground the equipment to
prevent electrical shock and
mutual interference.
Ground
Ground wire
wire
3-9
4. WIRING
This chapter provides the information necessary for wiring the CSH-83/84. Wire the equipment
referring to the drawings shown in the table below.
Display Unit CN-A5 Interface Unit J201
320
4-1
4.2 How to Use the Crimping Tool and Pin Extractor
A crimping tool is necessary for connection of wires to the contact pins of the 38P connector.
The pin extractor removes the contact pin from the connector body. This paragraph describes
how to crimp and extract a contact pin.
1. Push the pin extractor into the pin hole from the side
opposite to the pin inserting side.
2. Push in the head of the pin extractor. The retaining
spring comes free and the contact pin can be removed.
4-2
REMOTE
CONTROL BOX
*4
RECEIVER UNIT
10S1277, 7 m
10S1258-1
(Max. 20 m)
*3
DPYCY-1.5
10S1259
(Max. 20 m)
4.3 Location of Connectors
10S1261 (Max. 5 m)
Notes:
4-3
Q Figures in centimeters are the
cable lengths required inside the
units, including lengths for cable
fabrication.
Q (*1) + (*2) < 100m, (*2)< 20 m
L
45 Anticorrosive
Shield 40 sheath
L = 250 (CN-A1)
320 (CN-A5)
170 (J201)
Vinyl sheath L = 470 (CN-A1) for Processor Unit
Armor 440 (CN-A5) for Processor Unit
Core
Insulating tape
Position No.
Insulate unused wires
with vinyl tape. Guide Pin A Guide Pin B
(Large) (Small)
4-4
Positioning guide pins
The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.
Connector
CN-A1 CN-A5 J201 Guide Pin Setting Tool
Guide Pin
Fix the cable in the clamp where shield is folded back onto the armor.
Cable clamp
Shield + armor
Anticorrosive sheath
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
Armor Vinyl sheath ,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,, Armor
#2
,,,,,,,,,,,,,
,,,
#3 ,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
#1
,,,,,,,,,,,,, Vinyl
Solder lead wire to armor and Taping ,,,,,,,,,,,,, sheath
4-5
Assembling BNC connector (CN-A7, CN-A8, CN-A9, CN-A10,
CN-A11, CN-A12)
Shield
4
4. Shorten the insulator, leaving 3 mm.
3
4-6
4.5 Cable Fabrication and Connector Assembling in
Power Unit
Assembling 38P connector (CN-E1)
A
1. Bundle unused wires outside the connector case.
2. Fix the cover 1, noting the cable outgoing direction.
3. Dress the wires and fix the covers 2 and 3. Use a fragment of
cable sheath to fix the wires at the cable clamp.
Cable outgoing
4. Shorten unused wires and tape their ends with vinyl tape to prevent direction
short circuit.
Cover 3
Fragment of
anticorrosive sheath
Cover 1
Position No.
4-7
Positioning guide pins
The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.
Connector
CN-E1 Guide Pin Setting Tool
Guide Pin
270
M4 (YEL) x 2
Armor
Anticorrosive
Armor Vinyl
sheath
sheath
Conductor Vinyl
2
Note: DPYCY-3.5 is Japan standard cable. S = 3.5 mm sheath
Use equivalent cable. ø = 2.4 mm
4-8
4.6 Cable Fabrication and Connector Assembling in
Transmitter Unit
Assembling 38P connector (CN-B2, CN-B3, CN-B4)
Cover 3
Fragment of
anticorrosive sheath
Cover 1
Position No.
4-9
Positioning guide pins
Guide pins of the connector are used to identify the mating receptacle. Position them as shown
the table below.
Connector
CN-B2 CN-B3 CN-B4 Guide Pin Setting Tool
Guide Pin
250
4-10
4.7 Cable Fabrication and Connector Assembling in
Hull Unit (incl. receiver unit)
Assembling 38P connector (CN-C1, CN-C3, CN-C4)
20P connector (CN-C2)
Fabrication of cable for 38P and 20P connectors
CN-C1, CN-C3 CN-C2, CN-C4
200 Anticorrosive L
45 45 Anticorrosive
Shield sheath Shield sheath
40 40
Vinyl sheath
Vinyl sheath
Armor Armor
L = 200 (CN-C2)
250 (CN-C4)
Cover 3
Fragment of
anticorrosive sheath
Cover 1
Position No.
4-11
Positioning guide pins
The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.
Table 4-4 Connectors CN-C1, CN-C2, CN-C3, CN-C4 and guide pins
Connector
CN-C1 CN-C2 CN-C3 CN-C4 Guide Pin Setting Tool
Guide Pin
Anticorrosive sheath
35
Anticorrosive
sheath 90
Vinyl tape
M3 (RED) x 12
4-12
Fabrication of cable 10S1259 (connected to terminal board TB-D2
in raise/lower control box)
Armor
3.5sq
x3 M4 (YEL) x 3
30 5 1.25sq
x2 M4 (RED) x 2
70
P1 Transducer
P2
cable
P3
P4 TD COMMON
P5 Connector
Puller
Ground wire
CN-C4
(supplied) whenever
unplugging connectors.
Lead the cables into the receiver unit and
clamp them as shown below.
4-13
4.9 Connection of Interface Unit CS-120A
With connection of navigator, the Interface Unit CS-120A and electronic fishing equipment,
the function of the CSH-83/84 series is expanded to include true motion presentation, target
lock, echo sounder picture, FNZ marker presentation and digital indication of position, water
temperature and depth. This chapter provides the information for interfacing the CSH-83/84
series with external equipment.
• Heading data is fed to J205 from A/D Converter AD-100 and the speed pulse data to
J206 from the speed log.
• Both heading and speed data are fed to J207 or J204 from the CIF line of the
CI-30/50/60.
• NMEA signal is fed to J208 (NMEA port) or J207 (CI/NMEA port).
J205 J208
A/D CONV. GYRO NMEA NMEA Signal
AD-100 Heding Data
J207
CI/NMEA NMEA Signal or
CIF Current Signal
ELECTROMAGNETIC INTERFACE
LOG (CS-120A)
J206
LOG
Speed Pulse Data
DISPLAY UNIT
DOPPLER (CSH-830)
SONAR
CURRENT
INDICATOR
CIF 10S1148 J204 CN-A5
DOPPLER (20m MAX) CIF
SONAR J201
CURRENT Heading Data
INDICATOR True Heading Data
Speed Data
Current Data 10S1258
4-14
There are six combinations of CIF/NMEA data input.
Combination NMEA port CIF port CI/NMEA port
J208 J204 J207
1 NMEA data - NMEA data
2 NMEA data - CIF current data
3 - CIF data CIF current data
4 NMEA data - -
5 - CIF data -
6 - - NMEA data
Note: NMEA port and CIF port are not fed a data at the same time. Either CIF current data
or NMEA data can be fed to CI/NMEA port.
Do not feed Speed pulse data when speed data is fed from NMEA or CIF port and the
current indicator is chosen as own ship’s navigation data (refer to page 7-5). If they are fed
at the same time, the moving distance data will be doubled.
Receivable Data
4-15
Connections for ES picture and FNZ markers
To provide echo sounder picture and FNZ markers, connect echo sounder to J203 and net
sonde to J202. The signals applied to J202 and J203 are
J202: Net sonde signal and trigger signal (keying pulse of echo sounder). A white line
signal from an echo sounder may be additionally applied as described on the next
page if the digital depth data is not available on J204.
J203: Echo signal and keying pulse from an echo sounder.
INTERFACE
UNIT
(CS-120A)
Connection 2: Displaying echo sounder picture and FNZ markers by one echo
sounder
FNZ JOINT BOX
(CS-170)
SONDE 1 J202 (SONDE)
J701
(FNZ) TB-1
TB-2
SONDE
2
(FNZ) TB-1
J203 (E/S)
J705 TB-2
SONDE
(FNZ) 3 INTERFACE
UNIT
(CS-120A)
E/S VI-1100A
This method is used when the net sonde is installed and both echo sounder and net sonde
signals are taken from the same echo sounder. The net sonde signal is applied to both J202
and J203.
E/S VI-1100A
4-16
Connections for digital indication of position,
water temperature and depth
The data for these readouts are taken from the equipment shown in the table below and
input to J208 or J204. Input to J208 if the data is NMEA format, or to J204 if the data is CIF
format.
Data Data Source
Position Loran C navigator, GPS navigator
Temperature Indicator T-2000/TI-20, nav equipment or
Water Temperature
color video sounder connected to temperature sensor
Depth Color video sounder
Note: When a sounder which has digital depth data output is not available, the white line
signal of a paper recording echo sounder can be used to provide digital depth
readout. Connect the echo sounder as shown below or as shown in connection 2 or
3 on previous pages and operate the echo sounder front panel controls so that the
white line is effected on the seabed contour.
Trigger (KP)
J202 (SONDE)
white line sig.
J701
E/S VI-1100A CS-170 J203 (E/S)
J705 TB-1
INTERFACE
UNIT
(CS-120A)
Wiring
Connect referring to the Interconnection Diagram at the back of this manual.
4-17
Assembling 10P and 7P connectors
10P Connector (SRCN6A16-10P) J202 (FNZ), J204 (CIF), J205 (GYRO), J207 (CI)
8cm
1cm 2cm
BRAIDED
SHIELD
m
3m
VINYL SHEATH VINYL SHEATH
(OUTER) (INNER)
EARTH WIRE
SOLDER UNUSED CORES
AND EARTH TO
BRAIDED SHIELD
CLAMP FIXING SCREW
SET SCREW
CLAMP
SOLDERING WIND SHIELDING TAPE
CONNECTOR CASE
SOLDERING-SIDE
2cm
BRAIDED
SHIELD
VINYL SHEATH
SOLDERING-SIDE
EARTH
SOLDER UNUSED CORES WIRE CLAMP FIXING SCREW
AND EARTH WIRE TO SET
BRAIDED SHIELD
CLAMP SCREW
VINYL SHEATH
CONNECTOR CASE
WIND VINYL TAPE
4-18
4.10 Connection of Sub-Display Unit (option)
The Sub-Display Unit CSH-236 controls the sonar from a remote location, and its outline di-
mensions and control panel layout are identical to the display unit. One sub-display unit can be
connected to three display units.
Connections
Refer to the interconnection diagram on page S-1 and the connector assembling/cable fabrica-
tion procedure on page 4-4.
Note: A sub-display unit may not be connected to different models (for example, CSH-73 and
CSH-24).
SW
Used for Description
No.
1 Display unit on CH-1 ON: Turning on the sub-display unit automatically turns on
2 Display unit on CH-2 the display unit.
3 Display unit on CH-3
4 Display unit on CH-1 ON: Turning on the display unit automatically turns on the
5 Display unit on CH-2 sub-display unit.
6 Display unit on CH-3 OFF: Sub-display unit is turned on.
7 Remote ON/OFF Used in remote display unit. Set to ON in sub-display unit.
8 Not used
Note: You may wish to have both the display unit and a sub-display unit turn on when one is
turned on. To do this turn on both #1 and #4.
4-19
4.11 Connection of Remote Display Unit (option)
Three display units may be connected to one remote display unit. Operating controls provided
on the remote display are power on/off switch, brilliance control and channel selector, which
selects a display unit.
Connections
Refer to interconnection diagram on page S-1 and cable fabrication/connector assembling pro-
cedure on page 4-11.
Note: The display unit has two ports: one for sub-display unit and the other for remote display
unit. When there is no sub-display unit, both ports can be connected to remote display units.
Set DIP switch S1 on RDCB board 10P6724 in the remote display unit referring to the table and
figure below.
SW
Used for Description
No.
1 Display unit on CH-1 Not used.
2 Display unit on CH-2
3 Display unit on CH-3
4 Display unit on CH-1 Turn on when display unit is connected; turn OFF when not
5 Display unit on CH-2 connected.
6 Display unit on CH-3
7 Remote ON/OFF ON: Remote display unit turns on when a display unit is
turned on. Remote display turns off when all display
units are turned off.
OFF: Remote display is turned on/off by its ON/OFF switch.
4-20
4.12 Synchronizing Transmission with Other Sonars or
Echo Sounders
You may synchronize transmission with other sonars or echo sounders.
Connections
a) For current driven KP b) For voltage driven KP
Figure 4-33 Connections for synchronizing transmission with other sonars or echo sounders
Menu setting
Set polarity of the KP on the INIT/SET menu. Set transmission cycle to “0” on data setting
window. Refer to the operator’s manual for further details.
4-21
4.13 Interlocking Operation with Other Sonars
Functions (range, tilt, fish marks, etc.) and remote control may be mutually interlocked with
those on other sonars (CSH-23/24/73/83/84). For example, if the range is interlocked, changing
the range in one sonar automatically sets the other sonar to the same range. The functions to be
interlocked can be selected on the SYSTEM menu. See the operator’s manual for further de-
tails.
Sonar 1 Sonar 2
CN-A4 CN-A4
TD H A E RD H
P
TD C B F RD C
RD H E A TD H
P
RD C F B TD C
Three sonars
TD RD
Sonar 1 Sonar 2
RD TD
TD RD
Sonar 3
Set ID code with DIP switches #1 thru #3 on the display unit. Any code is acceptable, provided
that it is not the same as that set on the other sonar. For how to access the DIP switches see page
7-3.
4-22
Connections for interlocking remote control
A single remote control box can control three display units. Connect it to the display units as
shown below.
REMOTE CONTROL
4-23
5. CHANGING POWER SPECIFICATIONS
The display unit is set at the factory for connection to ship’s mains of 100 VAC. To power it by
110 VAC or 220 VAC, use step-down transformer PT-400, change the transformer taps on the
power unit as below and connect the ship’s mains directly.
Ship's
Mains
For 100 VAC Ship's Mains
Ship's
Mains
For 110 VAC Ship's Mains
Ship's
F Photo No.1747
Mains
For 220 VAC Ship's Mains
POWER UNIT
5-1
6. INSTALLATION OF FRP RETRACTION TANK
1. Clean the surface of the tank flange. Coat the flange with about 1 mm thickness of sealant
(Three Bond 1101, supplied).
Note: Use only the sealant supplied.
Sealant
2 mm 1 mm
100 mm
FRP Tank
2. Lay the waterproofing gasket on the tank flange and coat the gasket with about 1 mm thick-
ness of sealant.
6-1
Sealant
Waterproofing
gasket
3. Orient the bow mark (arrow) on the hull unit flange toward ship’s bow. (If the mark cannot
be perfectly oriented toward ship’s bow adjust heading after installation as shown in the
next chapter.)
Hull unit flange
Ship's
bow
4. For the 1200 mm stroke hull unit, insert insulation gaskets in each of the 11 holes for stud
bolts on the tank flange. (Do this before setting the hull unit to the retraction tank.)
Insulation
gasket
5. Before setting the hull unit on top of the retraction tank, observe the following cautions:
• Clean the hull unit flange to make sure no foreign material has fallen into the retraction
tank.
• Confirm that waterproofing gasket is in place.
6-2
Bolt
hole
6. Set the hull unit on top of the retraction tank. Pass flat washer onto hex bolt and insert them
in stud bolt hole from the top of the hull unit flange. At the retraction tank, fasten the bolt
with insulation gasket, flat washer, spring washer and nut, in the order shown in the figure
below.
Hex bolt
Flat washer
Insulation gasket
Hull unit flange
Tank flange
Insulation gasket
Flat washer
Spring washer
Nut
7. Install stays from the top of the hull unit, using the eye bolts.
Stay
Stay
Post
6-3
7. ADJUSTMENT AND CHECK
light.
OFF ON
2. Confirm that the 5V and UP lamps on the raise/
lower control box are lit.
3. Remove the cover of the raise/lower control box
and check the following voltages:
Figure 7-1 Display unit front panel
Terminal Terminal No. Voltage
TB-D1 7–8 +12 V
1–2 100 VAC
TB-D2 2–3 100 VAC
1–3 200 VAC
7-1
11. Press the d switch. Confirm that the lamp above the switch blinks while the transducer is
being lowered, a short beep sounds when the mid limit switch kicks, and the lamp lights
when the transducer is fully lowered.
12. Press the c switch. Confirm that the lamp above the switch blinks while the transducer is
being raised, a short beep sounds when the mid limit switch kicks, and the lamp lights when
the transducer is fully raised.
13. Press the OFF switch. Confirm that the transducer is completely retracted and then the
power is turned off.
14. With the transducer lowered, confirm that the transducer is raised when c or OFF is pressed.
1. Locate a target in the bow direction (buoy, for example) and display it on a near range. If the
target appears at 12 o’clock the heading alignment is correct and no further adjustment is
necessary. If it is not go to step 2.
Bow
If target's on-screen
Buoy position is right of ship's
bow, for example, hull unit
e heading is skewed to left.
2. Turn on the power while pressing and holding down the MENU key. The INIT SET/TEST
menu appears.
OTHERS
7-2
INIT SET/TEST MENU
4. Enter heading correction with [ or \, referring to the example in the table below for
guidance.
DISPLAY UNIT
7-3
DSW Board (10P6722F)
7-4
7.4 Setting and Adjustment of the Interface Unit
CS-120A
DIP switch setting
Navigation data and fishing data input from external equipment can be turned on or off by
DIP switches DP-1 and DP-2 on CPU II board 10P6871 in the Interface Unit CS-120A.
DP-2 CI/NMEA port Input format
ON
Input format S1
1 2 3 4
Interface board
(10P0047)
R78
DP-1
ON Own ship's navigation data (Gyrocompass, Speed log or Current indicator etc.)
1 2 3 4 5 6 7 8
7-5
DP-1
ON Talker check (only for NMEA signal)
1 2 3 4 5 6 7 8
S4
Talker is checked. OFF
Talker is not checked. ON
Talker of GP, SD, VD, etc. is checked.
R27
Interface board
R36
(10P0047)
R55
R56
S01
S02
Setting for DIP switch
S01: The FNZ marker is plotted on the echo sounder picture with this
switch turned on when FNZ marker signal is fed to External Interface.
Factory setting is the “ON” position.
S02: Selects the signal mode (AC or DC) according to the combined echo
sounder connected. Factory setting is the “AC” position.
7-6
Adjustment of signal level (R36, R56)
1. Set the MODE switch to E/S.
2. Turn the potentiometer R36 to suppress a noise, and the potentiometer R56 so that the
color gradation of the E/S picture on the screen appears similar to the intensity
gradation of the combined E/S echogram.
Basic priority
1. NMEA data > CIF data
2. NMEA data: NMEA port data > CI/NMEA port data
3. CIF data: CI/NMEA port data > CIF port data
Heading priority
1. Heading data from GYRO port
2. GP-HDT from NMEA port (GP-HDT: HDT sentence with talker GP)
3. GP-HDT from CI/NMEA port
4. VD-VHW from NMEA port
5. VD-VHW from CI/NMEA port
6. VD-CUR from NMEA port
7. VD-CUR from CI/NMEA
8. CIF signal <66> from CI/NMEA port
9. CIF signal <66> from CIF port
7-7
Depth priority
Depth is set to CIF/NMEA with S5 on the DIP switch DP-1.
1. SD-DPT from NMEA port
2. SD-DPT from CI/NMEA port
3. SD-DBT from NMEA port
4. SD-DBT from CI/NMEA port
5. <57> from CIF port
7-8
REMOTE
CONTROL BOX *
DISPLAY UNIT
RECEIVER UNIT
RAISE/LOWER
CONTROL BOX INTERFACE UNIT
10S1258-1
10S1277, 7 m
*3 (Max. 20 m)
DPYC-1.5
10S1259
INVERTER
interconnection diagram are as follows.
(Max. 20 m)
10S1261 (Max. 5 m) TR-2435
DC 20 V AC 100 V
- +
POWER UNIT
8-1
DPYC-1.5
24 VDC
10S1258-1
10S1260 (Max. 40 m) (Max. 20 m)
10S1260 (Max. 20 m)
DPYCY-4 10S1258-1
10S1259 (Max. 20 m)
Notes:
TR INVERTER CURRENT LIMITER BOX
limiter box CSH-1400. (All units are optional supply.) The system diagram and
24 VDC
When the ship’s mains is 24 VDC, use DC/AC inverter unit TR-2435, TR-24100 and current
Transmitter Unit
CSH-810
TB-B1
1 2 3 4 5 6
P
Display Unit
CSH-830
CSH-8400
Power Unit
CSH-880 CN-A15
TB-E1
*DPYCY-3.5 *DPYCY-3.5 3
CN-E1 2 1
2
2
1
3
TR Inverter
4 TR-24100
5 RED
6 BLK
7 WHT 100 VAC 100 VAC
8 BRN OUTPUT OUTPUT
P
9 BLK
1 kVA 350 VA
10 RED
11 BLK INPUT INPUT
12 WHT 24 VDC 24 VDC
13 BRN - + - +
P
14 BLK
15 Inverter
10S1259
10S1259
16 TR-2435
*DPYCY-5.5
*DPYCY-3.5
P P
RED BLK WHT BRN BLK RED BLK WHT BRN BLK
24 VDC
1 2 3 4 5 6 1 2 3 4 5 6 Ship s mains
TB-01 TB-02
Current Limiter Box CSH-1400 *: Local supply
8-2
9. PROCESSOR UNIT CSH-835
(BLACKBOX TYPE FOR CSH-83)
Mounting procedure
1. Remove the mounting base by unscrewing the two bolts at the front bottom.
2. Fix the mounting base to the table or deck by using six self-tapping screws 6x20
(supplied).
3. Place the unit on the mounting base, slide it forward and then fasten it to the mounting
base with two bolts.
(133)
140±1
220
°)0
(9
7
9-1
9.2 Monitor
Use a commercially available monitor having the specifications shown below.
• Signal: Analog RGB, 0 – 0.9 V, Positive, 75 Ω
• Synchro. signal: Horizontal, TTL level, 31.687 kHz±4 Hz, 75 Ω
Vertical, TTL level, 60.111 Hz±0.007 Hz, 75 Ω
• Resolution: VGA, 664 x 481
Mount the monitor in portrait orientation. Note that FURUNO monitor model MU-151C can be
used in portrait orientation.
Cable entrance
DISPLAY
RGB port panel R
B D-sub
15P
H
Power supply port
V
BNC
FUSE
5A
H C
2 3
100 VAC
50/60Hz
2A 1
GND
Ground terminal
CAUTION
Securely attach protective earth
to the ship's body.
The protective earth is required
to prevent electrical shock.
9-2
Connectors for Monitor
There are two kinds of video signal ports: D-sub connector (default) and BNC connectors.
• D-sub: Use interconnection cable 3COX-2P-6C (5 m or 10 m) or equivalent commercially
available cable.
• BNC connector: Use five 75 Ω coaxial cables (shipyard supply). The coaxial cables are
preferred in case of longer than 10 m cable run between the processor unit and monitor.
Screw (4 pcs)
J21
BNC connector
R
G
Replace each
B BCN connector
H to the same
label port.
V
J3
9-3
A-1
PACKING LIST 10CJ-X-9851 -1 1/1
CSH-235/235K/235F/535/585/735/835
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT
操作制御部 CSH-235
1
PROCESSOR UNIT
000-070-191 **
予備品 SPARE PARTS
予備品 SP10-03201
1
SPARE PARTS
006-030-590
工事材料 INSTALLATION MATERIALS
工事材料 CP10-06301
1
INSTALLATION MATERIALS
006-030-600
1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL.
000-549-064
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
+トラスタッピンネジ 1種 6X20 SUS304
1 6
SELF-TAPPING SCREW
CODE NO. 000-802-084
コネクタ(NCS) NCS-253-P
2 1
CONNECTOR(NCS)
CODE NO. 000-506-503
10CJ-X-9401
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-4
000-126-852
ヒューズ FGMA 2A AC125V 指示装置用
000-126-841
ヒューズ FGMA 1A AC125V 指示装置用
000-126-840
ヒューズ FGMA 3A 指示装置用
125V(UL)
4 FUSE 1 2 FOR DISPLAY UNIT
000-111-848
管入りヒューズ F-7165 20A 指示装置用
AC250V
5 FUSE 1 2 FOR DISPLAY UNIT
000-547-022
XHコネクタ組品 10-286(15P) 受信装置用
000-549-062
コネクタ抜き工具 10-038-3901-0 受信装置用
000-547-022
XHコネクタ組品 10-285(10P) 受信装置用
000-549-062
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(SRCN) SRCN2A16-7P 外部インターフェース工材用
FOR INTERFACE UNIT
1 1
CONNECTOR(SRCN)
CODE NO. 000-508-652
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1290-M01-H
A-7
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
クーラーパテ 200Gイリ シロイロ 指示装置工材用
FOR DISPLAY UNIT
11 2
COOLER PUTTY
CODE NO. 000-807-621
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1290-M02-H
A-8
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
アース板 WEA-1004-0 受信装置工材用
FOR RECEIVER UNIT
21 1
COPPER STRAP
CODE NO. 500-310-040
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1290-M03-H
A-9
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
ホールプラグ NO.4567 送振装置工材用
FOR TRANSMITTER UNIT
31 4
HOLE PLUG
CODE NO. 000-800-729
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1290-M04-H
A-10
A-11
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(8016) 00-8016-038-313761HV 外部インターフェイス用
FOR DATA INTERFACE
1 1 UNIT
CONNECTOR(8016)
CODE NO. 000-127-234
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1296-M01-B
A-12
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
クーラーパテ 200Gイリ シロイロ 指示装置用
FOR DISPLAY UNIT
11 2
COOLER PUTTY
CODE NO. 000-807-621
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1296-M02-B
A-13
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
アース板 WEA-1004-0 受信装置用
FOR RECEIVER UNIT
21 1
COPPER STRAP
CODE NO. 500-310-040
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1296-M03-B
A-14
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
ホールプラグ NO.4567 送振装置用
FOR TRANSMITTER UNIT
31 4
HOLE PLUG
CODE NO. 000-800-729
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
C1296-M04-B
A-15
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(8016) 00-8016-038-313761HV 外部インターフェイス工材
FOR INTERFACE UNIT
1 1
CONNECTOR(8016)
CODE NO. 000-127-234
10CL-X-9401
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-16
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
P貼りマーク.11. 10-026-0619-0 受信装置工材
FOR RECEIVER UNIT
11 1
P STICKER.11.
CODE NO. 100-014-880
10CL-X-9401
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-17
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(54) 54-038-000-601/SC 送信装置工材
FOR TRANSMITTER UNIT
21 3
CONNECTOR(54)
CODE NO. 000-132-081
10CL-X-9401
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-18
工事材料表
INSTALLATION MATERIALS
番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
圧着端子 FV5.5-4 電源装置工材
FOR POWER UNIT
31 15
CRIMP-ON LUG
CODE NO. 000-538-123
10CL-X-9401
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-19
A-20
A-21
A-22
A-23
A-24
A-25
A-26
D-1
D-2
Y. Hatai
D-3
D-4
D-5
Oct.31'03
D-6
SAME AS THE
10S1259,MAX.20m,φ16.5 -601/SC -313-761HV
他端に同じ
TT OTHER SIDE
POWER UNIT 10 アカ RED 1
1 CN-B2
10S1258,MAX.50m,φ18.6 CN-A1 1 外部インターフェイス
11 クロ BLK 2 送振装置 A アカ RED A 他端に同じ INTERFACE UNIT
CSH-880 12 シロ WHT 3 TRANSMITTER B チャ BRN
P
5 00-8016-038 00-8016-038 CS-120A
CN-E1 2
SAME AS THE
13 チャ BRN 5 UNIT C クロ BLK TT OTHER SIDE CN-A5 -313-761HV -313-761HV J201
TB-E1
14
P
6 CSH-810 D
P 10S1258,MAX.20m
クロ BLK シロ WHT *3 A A 他端に同じ
CN-A1に同じ
E ダイ ORG (*6) SAME AS THE
A
1
2
3
4
5
6
7
8
9
*3 *3 SAME AS
A F チャ BRN
P
CN-A1 TT TT OTHER SIDE
54-038-000
-601-SC
54-038-000 54-038-000 H アカ RED
10S1259,MAX.20m
*3
*3
-601/SC -601/SC LL
P CS-120C
WEA1004 1 CN-C3 10S1258,MAX.20m,φ18.6 CN-B3 1 ダイ ORG 5m
P 00-8016-038 00-8016-038
*3
受信装置 A アカ RED A 他端に同じ J クロ BLK
10S1260,MAX.20m
W=50,1.2m P P -313-761HV -313-761HV
RECEIVER UNIT B チャ BRN SAME AS THE K ハイ GRY *5 3 CN-A3 10S1258,MAX.30m CN-A1/A2/A3
アカ RED
クロ BLK
シロ WHT
チャ BRN
クロ BLK
TT OTHER SIDE
*1
DPYCY-4
CN-C4に同じ
TB-D2
P P P
1φ,50/60Hz
10S1627,7m
P P P CSH-116 P
ミドリ GRN K Y クロ BLK クロ BLK T HH アオ BLU クロ BLK X
P
クロ BLK M Z ミドリ GRN アオ BLU P JJ アオ BLU チャ BRN W
P P P P
5 アオ BLU L AA クロ BLK ムラサキ PPL U KK チャ BRN 10 クロ BLK Y
P
6 クロ BLK R BB クロ BLK V MM チャ BRN ミドリ GRN Z
P P P
*3 X CC ドウジク COAX. アオ BLU X NN シロ WHT 10S1258,MAX.30m CN-A4 4 *5 クロ BLK AA
*3 DD ミドリ GRN シロ WHT W PP ムラサキ PPL クロ BLK C BB
P P P
EE チャ BRN キ YEL Y RR チャ BRN シロ WHT D ドウジク COAX. CC
FF クロ BLK ミドリ GRN BB SS チャ BRN クロ BLK J ミドリ GRN DD
P P P P
HH アオ BLU クロ BLK FF TT ハイ GRY ハイ GRY K チャ BRN EE
JJ アオ BLU キ YEL CC キ YEL L アオ BLU JJ
P P *3 P
C101 KK チャ BRN ムラサキ PPL HH リモートディスプレイ チャ BRN M チャ BRN KK
#1 P1~P5 MM チャ BRN クロ BLK DD REMOTE DISPLAY キ YEL V ムラサキ PPL PP
P P P
*3 C102 NN シロ WHT アカ RED JJ CSH-106 *2 クロ BLK X チャ BRN RR
#2 P1~P5 PP ムラサキ PPL キ YEL KK CN-A1/A2/A3 チャ BRN W *3
送受波器 RR
P P
PP Y CN-A7
チャ BRN ハイ GRY 他端に同じ C クロ BLK R
CN-A8 ECX-3C2V-T,MAX.30m,
R (CN-A4/A7/A10)
TRANSDUCER SS チャ BRN アオ BLU LL SAME AS THE BB G G (CN-A5/A8/A11)
C C116 TT
P
ハイ GRY ハイ GRY
P
RR OTHER SIDE CC ドウジク COAX. CC B
CN-A9 (14S4382),φ13.7
B (CN-A6/A9/A12)
#16 P1~P5 *3 アカ RED MM NCS-253P H10P-SHF-AA CN-A13
P CN-A10 リモート箱
54-038-000 ハイ GRY SS 3 (CN-A4/A7/A10) R R 1
ECX-3C2V-T,MAX.30m, CN-A11 REMOTE BOX
3 CN-C4 -601/SC ミドリ GRN NN 2 (CN-A5/A8/A11) G G
10S1627,7m
10S1260,MAX.20m P φ13.7 CN-A12 CSH-116
他端に同じ A ハイ GRY TT 1 (CN-A6/A9/A12) B B
SAME AS THE *3
OTHER SIDE TT 10
上下装置 *3
WEA1004 *1 NCS-253P CN-A15
W=50,1.2m DPYCY-1.5
HULL UNIT 100VAC 3
DPYCY-1.5
*1 NCS-253P CN-A15
WEA1004 1φ,50/60Hz 2 100VAC 3
CSH-81080/81120 W=50,1.2m *1 *1 変圧器 1 1φ,50/60Hz 2
100VAC DPYCY-1.5 110/220VAC DPYC-1.5 TRANSFORMER 1
1φ,50/60Hz 1φ,50/60Hz PT-400 *2 WEA1004
W=50,1.2m WEA1004
W=50,1.2m
注記 NOTE
*1)造船所手配。 *1: SHIPYARD SUPPLY.
*2)オプション。 *2: OPTION. DRAWN TITLE
*5: DO NOT CONNECT RGB LINE (CONNECTOR FF/HH, MM/NN, SS/TT) OF Aug. 22 '06 T.Matsuguchi 相互結線図
*5)10S1258のRGBライン(FF/HH,MM/NN,SS/TT)は接続しないこと。 SCALE MASS NAME
画面の映像が歪む原因となることがあります。 CABLE 10S1258. OR INTERFERENCE MAY APPEARS ON THE DISPLAY. kg COLOR SCANNING SONAR
*6)88kHzセットでは、アジロがい装を指示装置に接地しないこと。 *6: DO NOT CONNECT CABLE ARMOR TO DISPLAY UNIT FOR 88kHz SET. DWG.No.
C1290-C01- K INTERCONNECTION DIAGRAM
1 2 3 4 5 6 S-2
送振装置 操作制御部
TRANSMITTER UNIT PROCESSOR UNIT RGB 10P6949 *3
CSH-23/23K/23F/53/58/83 3COX-2P-6C 5/10mまたは同等品 *2
CSH-235/235F/235K/ CN-A16 D-sub or equivalent D-sub
*7
送受信装置 *4 835/585/535/735 R 1 1
TRANSCEIVER UNIT G 古野製モニター MU-151C
A CSH-73 CN-B2 1 54-038-525-601/SC
B 択一
FURUNO MONITOR
A RED アカ P Selection
H 15 15 または OR
B BRN チャ CN-A15
*1 NCS-253P V 1
C BLK クロ
P DPYCY-1.5
1 GND D-sub 市販モニター(CRT/LCD)
D WHT シロ 100VAC 2 AC Commercially available monitor
1φ,50-60Hz 75Ω同軸ケーブル *2
E ORG ダイ 3 AC CN-A17 BNC
P Coaxial cable, MAX. 30m
F BRN チャ *7 R 15
H RED アカ トランス G
LL ORG ダイ
P TRANSFORMER B
J BLK クロ PT-400 H
P
K GRY ハイ V
110/220VAC
L YEL キ
P 1φ50-60Hz
M BRN チャ CONE 10P6711 J21 D-sub
N BLK クロ *4 *3
P 9pin 00-8016-038-313-761HV
P PPL ムラ CN-A5 5
R ORG ダイ A RED アカ P
P
S BLK クロ 00-8016-038 B BRN チャ
*4 -313-761HV *4
T BLK クロ C BLK クロ
P 1 CN-A1 P J201 1 外部インターフェイス
U RED アカ D WHT シロ 10S1258 or
10S1258 or *3
V YEL キ S10-10-20(38P),φ18.6 SAME AS E ORG ダイ S10-17-20(38P),φ18.6 SAME AS INTERFACE UNIT
P P CN-A5
B X BLK クロ 20m MAX.: CSH-58
50m MAX.: CSH-23/23F/23K/73/83
CN-B2 F
H
BRN チャ 20m MAX. CS-120A
W BRN チャ RED アカ
P 80m MAX.: CSH-53 P
Y BLK クロ LL ORG ダイ
Z GRN ミド J BLK クロ
P P
AA BLK クロ K GRY ハイ
BB SHIELD シールド L YEL キ 副指示器 *2
P
CC CO-AX 同軸芯線 M BRN チャ SUB DISPLAY UNIT
DD GRN ミド N BLK クロ CSH-236/236F/536/586
P P
EE BRN チャ P PPL ムラ
*3 00-8016-038-313-761HV CN-A1/A2/A3
FF BLK クロ R ORG ダイ
P H10P-SHF-AA 1 CN-A13 P RED アカ A *5
HH BLU アオ S BLK クロ P
リモート箱 10S1627 T BLK クロ
BRN チャ B
JJ BLU アオ BLK クロ C
KK BRN チャ
P REMOTE 7m U RED アカ
P
P
CONTROL BOX 10 WHT シロ D
MM BRN チャ V YEL キ
P ORG ダイ E
NN WHT シロ
P CSH-135/116 X BLK クロ P
BRN チャ F
PP PPL ムラ W BRN チャ
P P RED アカ H
RR BRN チャ Y BLK クロ P
ORG ダイ LL
SS BRN チャ Z GRN ミド
P P BLK クロ J
TT GRY ハイ AA BLK クロ P
GRY ハイ K
BB SHIELD シールド
*6 YEL キ L
C CC
DD
CO-AX 同軸芯線 P
BRN チャ M
GRN ミド
P BLK クロ N
EE BRN チャ P
PPL ムラ P
FF BLK クロ
P ORG ダイ R
HH BLU アオ P
BLK クロ S
JJ BLU アオ
P BLK クロ T
KK BRN チャ P
RED アカ U
MM BRN チャ
P YEL キ V
NN WHT シロ P
BLK クロ X
PP PPL ムラ
P BRN チャ W
RR BRN チャ P
BLK クロ Y
SS BRN チャ
P GRN ミド Z
TT GRY ハイ P
BLK クロ AA
注記 *6 SHIELD シールド BB
*1. 造船所手配。 CO-AX 同軸芯線 CC
*4 DD
*2. オプション。 P
GRN ミド
CN-A3 3 BRN チャ EE
*3. 圧着端子、コネクタは取付済み。 *2
SAME AS 10S1258,φ18.6 BLU アオ JJ
*4. □内の数値は誤挿入防止ガイドピンA(太)の位置を示す。 CSH-236/236F/536/536F
P
30m MAX. BRN チャ KK
ガイドピンB(細)はすべて”1”に設定。 *5 PPL ムラ PP
D *5. 10S1258のRGBライン(FF/HH,MM/NN,SS/TT)は接続しないこと。 P
BRN チャ RR
画像の映像が歪む原因となることがあり。
*1
*6. ケーブルクランプで接地。 *2
(CN-A7) R R (CN-A4/7/10)
*7. 同軸ケーブルを使用するときは内部でBNCコネクタを付けかえる。 (CN-A8) G
ECX3C-2V-T,φ13.7
G (CN-A5/8/11)
(14S4382)30m MAX.
(CN-A9) B B (CN-A6/9/12)
NOTES
*1. SHIPYARD SUPPLY.
*2. OPTION. DRAWN TITLE
*3. CONNECTOR/LAG FITTED AT FACTORY. Feb.15,'05 E. MIYOSHI CSH-235/235F/235K/835/585/535/735
*4. □ SHOWS POSITION OF CONNECTOR GUIDE PIN(LARGE). CHECKED NAME
GUIDE PIN(SMALL) IS SET ALWAYS TO POSITION '1'. TAKAHASHI. T カラースキャニングソナー操作制御部
*5. DO NOT CONNECT RGB LINE (FF/HH,MM/NN,SS/TT) ON 10S1258, OR *1 APPROVED
IV-8.0SQ. Y. Hatai 相互結線図
INTERFERENCE MAY OCCUR ON DISPLAY. PE 保護アース
SCALE MASS REMARK
*6. GROUNDED THRU CABLE CLAMP. kg COLOR SCANNING SONAR PROCESSOR UNIT
*7. WHEN COAXIAL CABLES ARE USED, REPLACE THE BNC CONNECTORS. DWG No.
C1304-C01- B INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1 2 3 4
インターフェイス
INTERFACE UNIT CIF
CS-120A J204 SRCN6A16-10P
DISP TD-H 1
(00-8016-038
J201 -313-761HV) TD-C 2
指示装置 10S1258,MAX.20m TTYCS-1 *1 航法機器
A RD-H 3
P NAV. EQUIPMENT
DISPLAY UNIT RD-C 4
A Z DTR-H 5
AA DTR-C 6
DSR-H 7
TT DSR-C 8
ゾンデ接続箱 NC 9
FNZ JOINT BOX SRCN6A SRCN6A FNZ GND 10
ネットゾンデ TB1 CS-170 J701 16-10P *2 16-10P J202 GYRO
NET SONDE VCTS-2x0.75 CO-0.2x5P SRCN6A16-10P
1 5 SONDE1-H 1 1 SONDE1-H J205
#1 P CO-0.2x5P *2 ADコンバータ
2 #2 6 SONDE1-C 2 2 SONDE1-C DATA-H 1
P AD CONVERTER
3 #3 7 SONDE2-H 3 3 SONDE2-H DATA-C 2
P AD-100
TB2 SONDE2-C 4 4 SONDE2-C CLK-H 3
P
3 SONDE3-H 5 5 SONDE3-H CLK-C 4
P
4 SONDE3-C 6 6 SONDE3-C GND 10
5 KP-H 7 7 KP-H CI/NMEA
P
6 KP-C 8 8 KP-C J207 SRCN6A16-10P
WL-H 9 WL-H CO-0.2x5P *2 潮流計
7 9 TD-H 1
P P CURRENT INDICATOR
8 WL-C 10 10 WL-C TD-C 2
インターフェイス RD-H 3
P
INTERFACE SRCN6A SRCN6A E/S RD-C 4
VI-1100A *3 DTR-H
02S8040,MAX.100m,φ9 16-7P J705 TB1 02S8040,MAX.100m,φ9 16-7P J203 5
P
B 1 シロ WHT 1 ES_SIG-H ES_SIG-H 1 シロ WHT 1 ES_SIG-H DTR-C 6
P P
2 アオ BLU 2 ES_SIG-C ES_SIG-C 2 アオ BLU 2 ES_SIG-C DSR-H 7
P
3 キ YEL 3 KP WL 3 キ YEL 3 KP DSR-C 8
4 ミドリ GRN 4 SONDE NC 4 4 NC NC 9
P
5 モモ PNK 5 WL TB2 モモ PNK 5 WL GND 10
6 ダイ ORG 6 SHIELD KP 3 ダイ ORG 6 SHIELD LOG
7 クロ BLK 7 GND GND 6 クロ BLK 7 GND J206 RM15TP-2PA
アカ RED アカ RED DPYC-1.5 *1 スピードログ
DATA-H 1
DATA-C 2
SPEED LOG
GND *1
IV-8sq. NMEA
J208 SRCN6A16-7P
インターフェイス TD-H 1
INTERFACE TD-C 2
VI-1100A RD-H 3 TTYCS-1 *1 GPS航法装置
魚群探知機 P GPS NAVIGATOR
1 シロ WHT RD-C 4
E/S P
2 アオ BLU NC 5
3 キ YEL SHIELD 6
4 ミドリ GRN GND 7
5 モモ PNK
注記 6 ダイ ORG
CS-120C,5m
C 7 クロ BLK
*1)造船所手配。 アカ RED
*2)オプション。
*3)魚探が一台のときのみ接続。 DRAWN TITLE
ネットゾンデ不使用時 Jun. 19 '06 T.YAMASAKI CS-120A
WHEN NET SONDE IS NOT USED. CHECKED 名 称
NOTE Jul. 4 '06 T.TAKENO インターフェイス
*1. SHIPYARD SUPPLY. APPROVED
Jul.24 '06 T.Matsuguchi 相互結線図
S-3