You are on page 1of 107

Back

COLOR SCANNING SONAR

MODEL CSH-83/84
The paper used in this manual
is elemental chlorine free.

FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya 662-8580, JAPAN

Telephone : 0798-65-2111
Fax : 0798-65-4200

All rights reserved. Printed in Japan FIRST EDITION : OCT. 1997


H3 : OCT. 05, 2006
Pub. No. IME-13090-H3
*00080806812*
( TATA ) CSH-83/84 *00080806812*
*00080806812*

*IME13090H30*
*IME13090H30*
*IME13090H30*
SAFETY INSTRUCTIONS

WARNING WARNING
Do not open the cover Install the specified transducer tank
unless totally familiar with in accordance with the installation
electrical circuits and instructions. If a different tank is to be
service manual. installed the shipyard is solely respon-
sible for its installation, and it should
High voltage exists inside the be installed so the hull will not be
equipment, and a residual damaged if the tank strikes an object.
charge remains in capacitors
several minutes after the The tank or hull may be damaged if the
power is turned off. Improper tank strikes an object.
handling can result in electri-
cal shock. If a steel tank is installed on a wooden
or FRP vessel, take appropriate
Turn off the power at the switchboard measures to prevent electrolytic
before beginning the installation. corrosion.
Fire or electrical shock can result if the Electrolytic corrosion can damage the
power is left on. hull.
Do not install the equipment where it Be sure that the power supply is
may get wet from rain or water splash. compatible with the voltage rating of
the equipment.
Water in the equipment can result in fire,
electrical shock or equipment damage. Connection of an incorrect power supply
can cause fire or equipment damage. The
Be sure no water leaks in at the trans- voltage rating of the equipment appears
ducer installation site. on the label above the power connector.
Water leakage can sink the vessel. Also
confirm that the transducer will not loosen
by ship’s vibration. The installer of the
equipment is solely responsible for the CAUTION
proper installation of the equipment.
FURUNO will assume no responsibility for Ground the equipment to
any damage associated with improper prevent electrical shock and
installation. mutual interference.

Observe the following compass safe


distances:
Standard Steering
Display unit
0.9 m 0.68 m
for CSH-83

Display unit
for CSH-84 1.7 m 1.3 m

Processor
unit 1.70 m 1.05 m

i
TABLE OF CONTENTS

1. SYSTEM CONFIGURATION ......................................................... 1-1


2. EQUIPMENT LISTS ...................................................................... 2-1

3. MOUNTING THE EQUIPMENT


3.1 Mounting the Hull Unit and Receiver Unit ................................................................ 3-1
3.2 Mounting the Display Unit and Sub-Display Unit (option) .......................................3-7
3.3 Mounting the Transmitter Unit ...................................................................................3-8
3.4 Mounting the Power Unit ...........................................................................................3-8
3.5 Mounting the Interface Unit .......................................................................................3-8
3.6 Mounting the FNZ Joint Box ..................................................................................... 3-8
3.7 Grounding the Equipment ..........................................................................................3-9

4. WIRING
4.1 Cable Configuration ...................................................................................................4-1
4.2 How to Use the Crimping Tool and Pin Extractor ..................................................... 4-2
4.3 Location of Connectors ..............................................................................................4-3
4.4 Cable Fabrication and Connector Assembling in Display and Interface Units ..........4-4
4.5 Cable Fabrication and Connector Assembling in Power Unit .................................... 4-7
4.6 Cable Fabrication and Connector Assembling in Transmitter Unit ...........................4-9
4.7 Cable Fabrication and Connector Assembling in Hull Unit (incl. receiver unit) ..... 4-11
4.8 Connection of Transducer Cables ............................................................................4-13
4.9 Connection of Interface Unit ....................................................................................4-14
4.10 Connection of Sub-Display Unit (option) ..............................................................4-19
4.11 Connection of Remote Display Unit (option) ........................................................4-20
4.12 Synchronizing Transmission with Other Sonars or Echo Sounders .......................4-21
4.13 Interlocking Operation with Other Sonars .............................................................4-22

5. CHANGING POWER SPECIFICATIONS

6. INSTALLATION OF FRP RETRACTION TANK


6.1 Before Beginning the Installation ..............................................................................6-1
6.2 Installation of the FRP Retraction Tank ..................................................................... 6-1

ii
7. ADJUSTMENT AND CHECK
7.1 Hull Unit Check .................................................................................................... 7-1
7.2 Heading Adjustment............................................................................................. 7-2
7.3 DIP Switch Setting in the Display Unit.................................................................. 7-3
7.4 Setting and Adjustment in the Interface Unit......................................................... 7-5

8. WHEN SHIP’S MAINS IS 24 VDC ................................................................................. 8-1

9. PROCESSOR UNIT CSH-835 (BLACKBOX TYPE FOR CSH-83)................................ 9-1

SPARE PARTS, INSTALLATION MATERIALS, ACCESSORIES......................................A-1


OUTLINE DRAWINGS...................................................................................................... D-1
INTERCONNECTION DIAGRAMS ....................................................................................S-1

iii
This page is intentionally left blank.
1. SYSTEM CONFIGURATION

STANDARD OPTION

MONITOR (MU-151C)
REMOTE CONTROL BOX DISPLAY UNIT or SUB DISPLAY *
CSH-116 CSH-830 (CSH-83) PROCESSOR UNIT * COMMERCIAL MONITOR CSH-236 * : CSH-83 only
CSH-8400 (CSH-84) CSH-835

or

SHIP'S MAINS
100 VAC, 1φ,
SHIP'S MAINS 50/60 Hz
100 VAC, 1φ,
50/60 Hz
TRANSMITTER UNIT
CSH-810

110/115/220/230 VAC, STEP-DOWN


1φ, 50/60 Hz TRANSFORMER
INTERFACE UNIT PT-400
CS-120A

SPEED LOG
AD CONVERTER
POWER RECEIVER UNIT NAVIGATOR
SUPPLY UNIT CSH-820 CURRENT INDICATOR
CSH-880
COLOR VIDEO SOUNDER
VI-1100A
INTERFACE UNIT

ECHO SOUNDER, COLOR


VIDEO SOUNDER
SHIP'S MAINS NET SONDE
100/110/220 VAC, 1φ, FNZ JOINT BOX
50/60 Hz CS-170

HULL UNIT
CSH-81080 (800 mm stroke)
CSH-81120 (1200 mm stroke)

1-1
2. EQUIPMENT LISTS
Standard Supply
Name Type Qty Remarks
Display Unit CSH-830 Select For CSH-83
CSH-8400 one For CSH-84
Processor Unit CSH-835 Blackbox type for CSH-83
Transmitter Unit CSH-810 1
Receiver Unit CSH-820 1 w/hull unit
Hull Unit CSH-81080 1 stroke 800mm
CSH-81120 stroke 1200mm
Power Unit CSH-880 1
Remote Control Box CSH-116 1
Interface Unit CS-120A 1
Installation Materials CP10-03000 1 set CP10-03010 For CSH-83
6 pair cable
CP10-03600 1 set CP10-03610 For CSH-84
6 pair cable
CP10-06600 1 set CP10-06610 For processor unit
6 pair cable
Accessories FP10-02400 1 set FP10-01801 For CSH-83
FP10-01201
FP10-01203
Nylon cover
RAM card
FP10-01900 1 set FP10-01201 For CSH-84
FP10-01203
FP10-01901
Nylon cover
RAM card
FP10-03000 1 set FP10-01203 For processor unit
RAM card
Spare Parts SP10-02000 1 set For CSH-83/84
SP10-03600 1 set For processor unit

2-1
Optional Equipment

Name Type Code No. Remarks


Sub-Display Unit CSH-236 - CSH-83 only
Inverter TR-2435 -
TR Inverter TR-24100 -
Step-down Transformer PT-400 - 200-230 VAC
37-core Cable 10S1258 000-101-006 Specify length
7-core Cable 10S1259 000-101-007 Specify length
16 Twisted Pair Cable CO-SPEV-SB-C 0.5x16P 000-101-008 Specify length
E/S Interface Unit VI-1100A -
FNZ Joint Box CS-170 -
Mounting Fixture OP10-9 006-990-040 For CSH-116
Current Limiter Box CSH-1400 - See page 8-1.
Extension Cable Set CSH-1300 000-069-996 For extending
transceiver cable
FRP Retraction Tank OP10-1 000-068-861
Retraction Tank SHG-0001 006-904-340
Hood FP10-01801 006-027-830 For CSH-83
Filter OP10-11 006-997-710 For CSH-83
Filter FP10-02000 000-908-560 For CSH-84
ROM Option Kit A OP10-15 006-998-620
ROM Option Kit B OP10-18 006-998-650

Optional Tools

Name Type Code No. Remarks

Crimping Tool 06-1001-016

Pin Extractor 06-1877-04 000-519-595

Guide Pin Setting Tool


10-910-0179-0

2-2
3. MOUNTING THE EQUIPMENT

3.1 Mounting the Hull Unit and Receiver Unit


Location of hull unit
Determine the mounting location through consultation with the shipyard and shipowner. When
deciding the location, consider the following points:
• Select an area where propeller noise, cruising noise, air bubbles and interference from turbu-
lence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow on or
near the keel is optimum. On-the-keel installation is advantageous for minimizing oil con-
sumption in comparison with off-the-keel. If the hull unit can not be installed on the keel, the
center of the retraction tank should be within 600 mm of the keel to prevent a rolling effect.

1/3 1/2
Within 600 mm

Figure 3-1 Hull unit mounting location

• Select a place where the hull bottom is flat and the draft is sufficiently deep. Normally, the
transducer should protrude at least 500 mm beyond the keel to minimize the effect of air
foam and bubbles.
• Select a place where interference from other equipment is minimal. Locate the hull unit at
least 2.5 m away from the transducers of other equipment.
• No obstacle should be in the fore direction since it causes a shadow zone and aerated water,
resulting in poor sonar performance.
• Secure sufficient space for wiring and maintenance. Refer to the hull unit outline drawing
for recommended wiring and maintenance space.
• If the ambient temperature of the hull unit is below 0°C, provide the sonar compartment with
a heater to keep the temperature above 0°C.

3-1
Heater

Heat insulator

Figure 3-2 Typical sonar compartment

3-2
Shortening the retraction tank
The retraction tank is 900 mm in length when supplied. Shorten the tank as necessary so that the
transducer is placed well below the keel when it is lowered. The following table provides guide-
lines for shortening the tank. Refer also to the retraction tank installation drawing at the back of
this manual.
Installation
Method
D D

XDCR Travel
800 mm Remove 0 to Same as left Remove 0 to Same as left
35 mm from 35 mm from
bottom. bottom.
Length D must
be less than
1150 mm.
1200 mm Remove 0 to Same as left Remove 0 to Same as left
35 mm from 35 mm from
bottom. bottom.
Length D must
be less than
1350 mm.

Figure 3-3 Guidelines for shortening the retraction tank

Note: When 35 mm is removed and “D” is minimum, the effect of air foam is minimized when
the transducer is fully protruding in water.

3-3
Remarks on installation of retraction tank
• If possible, the installation location should be of double bottom structure.
• If possible, install the tank on the keel, where the tank can be most firmly fixed.
• Install the reinforcement rib as near as possible to the top of the retraction tank, allowing
space for tightening bolts and nuts.
Retraction tank
Reinforcement rib

250–300 mm

Figure 3-4 Installation of reinforcement ribs

• When an attachment flange is used, install reinforcement ribs to the attachment flange.
Attachment flange

250–300 mm

Figure 3-5 Attachment flange

• Add a doubling plate where the retraction tank is welded to the hull bottom. The size of the
doubling plate is normally 1200 to 1300 mm in diameter so it lies across two bottom frames.

3-4
Installing hull unit on retraction tank
After welding the retraction tank and allowing sufficient time for cooling, install the hull unit as
follows:

1. Clean the O-ring and O-ring groove and coat them with a slight amount of grease. Place the
O-ring in position on the tank flange.
2. Lay the gasket (1) on the top of the tank flange.
3. Orient the hull unit so that the arrow on its flange points toward the ship’s bow.
4. 7 of the 16 bolt holes on the hull unit flange have already been fitted with bolts. Insert the
gasket (2) into the bolt holes of the tank flange to which these seven bolts are fitted. Note
that it is difficult to fit them after the hull unit has been placed on the tank.
5. Confirm that the O-ring and the gasket (1) are in position. Place the hull unit on the tank.
6. Coat every bolt, washer and nut with slight amount of grease to ease removal. Fit the insu-
lation gasket (2) into the bolt holes of both the tank and hull unit flanges. Fasten the hull unit
to the retraction tank with gasket (2), flat washers, spring washers and hex bolts.
7. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two
eye bolts at the top of the hull unit, referring to figure at the top of the next page.

Hex Nut
Hex Bolt Flat Washer
Flat Washer
Gasket (2)*
Gasket (2)*
Insulation Gasket (2) * Gasket (1)
Insulation Gasket (2)*
Hull Unit Flange
Gasket (2)*
Gasket (1) Flat Washer
Spring Washer
O-ring Hex Nut

Tank Flange
Insulation Gasket (2)* * Used only on 1200 mm
Gasket (2)* travel type.
Flat Washer
Spring Washer
Hex Nut

Figure 3-6 Installation of hull unit

3-5
Installing stays (anti-vibration measure)
Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron with
a size of 75 x 75 x 9 mm or more and at least two pieces should be used; one each to ship’s bow
and stern directions. If possible, install two more stays in ship’s transverse direction.

Stay

Stay

Hull Unit

Figure 3-7 How to install stays

Do not install the stays vertically as shown below. Vibration-resistance effect is reduced since
vibration is applied to the stays as rotation force. Install them horizontally.
Crossbeam
on ceiling

Stay

Eye bolt
Proper installation

Hull 90°
Unit

Figure 3-8 Proper and improper installation of stays

Fastening receiver unit to hull unit


Fasten the receiver unit to the left side of the hull unit as
shown at right. Raise/Lower
Control Box
A transducer cable protection cover has been fitted where (Attached at
Receiver
the receiver unit is to be fastened to the hull unit. Re- Unit factory)
move it when mounting the receiver unit.

Figure 3-9 Fastening the


receiver unit to the hull unit
3-6
3.2 Mounting the Display Unit and Sub-Display Unit (option)
The display unit and sub-display unit are designed for tabletop mounting. When selecting a
mounting location, consider the following conditions:
• Place where operating personnel are able to control the unit easily while observing the fish-
ing ground or the area surrounding the vessel.
• Place at least 1 m away from a magnetic compass and equipment which have a magnet (radar
magnetron, loudspeaker, high power transformer, etc.).
• Place not exposed to direct sunlight, water splashes or hot air.
• Place where maintenance and ventilation clearance shown in the outline drawings is en-
sured.
• Place where the CRT face is within ±45° from vertical.

Mounting the display unit/sub-display unit


1. Remove the mounting base by unscrewing the two bolts at the front bottom.
2. Fix the mounting base to the table by using four M10 bolts, flat washers, spring washers and
nuts. It is recommended that a rubber mat be placed under the mounting base to absorb
vibration.
3. Fasten the unit to the mounting base with two bolts. When the space around the unit is
limited, make wirings to the display unit first and then fasten the unit.
CRT viewing angle

45°
45°

Note: For the CSH-84, remove eye bolts


at the top of the display unit and set
cosmetic screws to eye bolt holes.

M10 bolt
Steel washer

Flat washer
Steel washer
Nut

Figure 3-10 Mounting the display unit and sub-display unit

3-7
3.3 Mounting the Transmitter Unit
The transmitter unit can be mounted with or without mounting legs. For use without mounting
legs remove them and use inside mounting holes.

Reinforce the transmitter unit against vibration by stays extending from the eyebolts on the top
of the unit.

Attach stay to
this eye bolt.

Mounting leg for


outside leg mounting

For mounting without legs,


remove legs and use inside
holes for mounting.

Figure 3-11 Transmitter unit

3.4 Mounting the Power Unit


The power unit can be installed in any dry, well-ventilated place.

3.5 Mounting the Interface Unit


The interface unit connects with several navigation and fishing equipment, so determine the
installation site with the wiring to them taken into account. Furthermore, the unit incorporates
a data selector and self-check switch, therefore select a place where they can be easily operated.

3.6 Mounting the FNZ Joint Box


The FNZ joint box interchanges both Tx trigger and sounder marker pulses from the echo
sounder and the net sonde. Therefore, install it as close as possible to the net-sonde indicator.

3-8
3.7 Grounding the Equipment
Ground all units with a suitable copper strap or ground wire. The location of the ground termi-
nal on each unit is shown below.

CAUTION
Ground the equipment to
prevent electrical shock and
mutual interference.

DISPLAY UNIT POWER UNIT TRANSMITTER UNIT

RECEIVER UNIT INTERFACE UNIT FNZ JOINT BOX

Ground
Ground wire
wire

Figure 3-12 Location of ground terminals on equipment

3-9
4. WIRING
This chapter provides the information necessary for wiring the CSH-83/84. Wire the equipment
referring to the drawings shown in the table below.
Display Unit CN-A5 Interface Unit J201

320

4.1 Cable Configuration

Figure 4-1 Cable configuration

4-1
4.2 How to Use the Crimping Tool and Pin Extractor
A crimping tool is necessary for connection of wires to the contact pins of the 38P connector.
The pin extractor removes the contact pin from the connector body. This paragraph describes
how to crimp and extract a contact pin.

Crimping Tool Contact Pin Pin Extractor


06-1001-016 60-8017-0313-00-339 06-1877-04

Figure 4-2a Crimping tool, contact pin, pin extractor

How to use the crimping tool


1. Strip the vinyl sheath of the wire to expose the core by 3.2
mm to 4 mm.
2. Hold the crimping tool horizontally and insert the contact
pin with its slit facing downward into the crimp hole on the
crimping tool.
3. Insert the wire onto the contact pin and squeeze the handle
until the ratchet releases. (Place the wire deep enough into
the contact pin so that its end comes in contact with the
stopper plate of the crimping tool.) With crimping completed,
pull the wire while holding the contact pin to make sure that
Figure 4-2b Crimping tool
the pin is fastened tightly.

How to use the pin extractor


If a contact pin is inserted into an incorrect hole on the
connector body, remove it with the pin extractor.

1. Push the pin extractor into the pin hole from the side
opposite to the pin inserting side.
2. Push in the head of the pin extractor. The retaining
spring comes free and the contact pin can be removed.

Figure 4-2c Crimping tool

4-2
REMOTE
CONTROL BOX
*4
RECEIVER UNIT

10S1277, 7 m
10S1258-1
(Max. 20 m)
*3
DPYCY-1.5
10S1259
(Max. 20 m)
4.3 Location of Connectors

10S1261 (Max. 5 m)
Notes:

4-3
Q Figures in centimeters are the
cable lengths required inside the
units, including lengths for cable
fabrication.
Q (*1) + (*2) < 100m, (*2)< 20 m

Q *3: These are Japan standard cables.

Use equivalent cables.


Q *4: For blackbox type, the processor

unit is provided instead of the


display unit.
*2
10S1258-1
10S1260 (Max. 40 m) (Max. 20 m)
*3 *1
DPYCY-4 10S1260 (Max. 20 m)
10S1259 (Max. 20 m) 10S1258-1

Figure 4-3 Location of connectors


4.4 Cable Fabrication and Connector Assembling in
Display and Interface Units
Assembling 38P connector (CN-A1, CN-A5, J201)
Fabrication of cable 10S1258-1

L
45 Anticorrosive
Shield 40 sheath
L = 250 (CN-A1)
320 (CN-A5)
170 (J201)
Vinyl sheath L = 470 (CN-A1) for Processor Unit
Armor 440 (CN-A5) for Processor Unit

Core
Insulating tape

Expose cores, and then wind


shield around the armor.

Figure 4-4 Fabrication of cable 10S1258-1

Assembling the 38P connector


Shorten unused wires and wrap their ends with vinyl tape to prevent short circuit.

Guide Pin A Guide Pin B

Position No.
Insulate unused wires
with vinyl tape. Guide Pin A Guide Pin B
(Large) (Small)

Figure 4-5 How to assemble the 38P connector

4-4
Positioning guide pins

The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.

Table 4-1 Connectors CN-A1, CN-A5, J201 and guide pins

Connector
CN-A1 CN-A5 J201 Guide Pin Setting Tool
Guide Pin

Guide Pin A (Large) 1 5 1

Guide Pin B (Small) 1 1 1


Type 10-910-0179-0

Clamping the cable

Fix the cable in the clamp where shield is folded back onto the armor.
Cable clamp
Shield + armor
Anticorrosive sheath

Figure 4-6 Clamping the cable

Assembling connector NCS-253P (CN-A15)


Cable DPYCY-1.25

,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
Armor Vinyl sheath ,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,, Armor
#2
,,,,,,,,,,,,,
,,,
#3 ,,,,,,,,,,,,,
,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
#1
,,,,,,,,,,,,, Vinyl
Solder lead wire to armor and Taping ,,,,,,,,,,,,, sheath

connect it to #1 pin of connector.


Conductor
Use cable DPYCY-1.25 2
(Japan standard cable) S = 1.25 mm
or equivalent cable. ∅ = 1.35 mm

Figure 4-7 Assembling connector NCS-253P

4-5
Assembling BNC connector (CN-A7, CN-A8, CN-A9, CN-A10,
CN-A11, CN-A12)

1. Remove vinyl sheath of the cable by


1 15 mm.
15

Housing Clamp Washer Nut


2. Pass the cable through the nut, washer,
2 gasket and clamp.

Center pin Gasket

3. Unravel the shield and fold it back


3
onto the clamp.

Shield

4
4. Shorten the insulator, leaving 3 mm.
3

5 5. Trim the shield as shown in the


drawing. Solder the center pin to the
conductor of the cable.

6 6. Pass the cable through the housing


and tighten the nut.
Figure 4-8 Assembling BNC connector

4-6
4.5 Cable Fabrication and Connector Assembling in
Power Unit
Assembling 38P connector (CN-E1)

Fabrication of cable 10S1260


200
45
Shield 40 Core Insulating tape

Vinyl sheath Anticorrosive sheath


Armor Fold back shield
onto armor.

Figure 4-9 Fabrication of cable 10S1260

Assembling the 38P connector TT

A
1. Bundle unused wires outside the connector case.
2. Fix the cover 1, noting the cable outgoing direction.
3. Dress the wires and fix the covers 2 and 3. Use a fragment of
cable sheath to fix the wires at the cable clamp.
Cable outgoing
4. Shorten unused wires and tape their ends with vinyl tape to prevent direction
short circuit.
Cover 3

Guide Pin A Guide


Pin B
Guide pin

Fragment of
anticorrosive sheath
Cover 1

Position No.

Guide Pin A Guide Pin B


Insulate unused Cover 2 (Large) (Small)
wires with vinyl
tape.

Figure 4-10 How to assemble the 38P connector

4-7
Positioning guide pins

The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.

Table 4-2 Guide pins and connector CN-E1

Connector
CN-E1 Guide Pin Setting Tool
Guide Pin

Guide Pin A (Large) 2

Guide Pin B (Small) 1


Type 10-910-0179-0

Clamping the cable


Cable clamp Shield + armor
Anticorrosive sheath

Figure 4-11 Clamping the cable

Fabrication of cable 10S1259 (connected to terminal board TB-E1)


Armor
3.5sq
x3 M4 (YEL) x 3
30 5 1.25sq
x2 M4 (RED) x 2

270

Figure 4-12 Fabrication of cable 10S1259

Fabrication of cable DPYCY-3.5 (connected to terminal board


TB-E1)
Cable DPYCY-3.5
330
35
30

M4 (YEL) x 2
Armor
Anticorrosive
Armor Vinyl
sheath
sheath
Conductor Vinyl
2
Note: DPYCY-3.5 is Japan standard cable. S = 3.5 mm sheath
Use equivalent cable. ø = 2.4 mm

Figure 4-13 Fabrication of cable DPYCY-3.5

4-8
4.6 Cable Fabrication and Connector Assembling in
Transmitter Unit
Assembling 38P connector (CN-B2, CN-B3, CN-B4)

Fabrication of cables 10S1258-1, 10S1260


300
45
Shield 40 Core Insulating tape

Vinyl sheath Anticorrosive sheath


Armor CN-B4: Fold back shield
onto armor.
CN-B2, B3: Expose cores;
wind shield
around armor.

Figure 4-14 Fabrication of cables 10S1258-1, 10S1260

Assembling the 38P connector

1. Bundle unused wires outside the connector case.


2. Fix the cover 1, noting the cable outgoing direction.
3. Dress the wires and fix the covers 2 and 3. Use a fragment of cable
sheath to fix the wires at the cable clamp.
4. Shorten unused wires and tape their ends with vinyl tape to prevent short Cable outgoing
circuit. direction

Cover 3

Guide Pin A Guide


Pin B
Guide pin

Fragment of
anticorrosive sheath
Cover 1

Position No.

Guide Pin A Guide Pin B


Insulate unused Cover 2 (Large) (Small)
wires with vinyl
tape.

Figure 4-15 How to assemble the 38P connector

4-9
Positioning guide pins

Guide pins of the connector are used to identify the mating receptacle. Position them as shown
the table below.

Table 4-3 Connectors CN-B2, CN-B3, CN-B4 and guide pins

Connector
CN-B2 CN-B3 CN-B4 Guide Pin Setting Tool
Guide Pin

Guide Pin A (Large) 1 1 3

Guide Pin B (Small) 1 1 1


Type 10-910-0179-0

Clamping the cable


Cable clamp Shield + armor
Anticorrosive sheath

Figure 4-16 Clamping the cable

Fabrication of cable 10S1259 (connected to terminal board TB-B1)


Armor
3.5sq
x3 M4 (YEL) x 3
45 5 1.25sq
x2 M4 (RED) x 2

250

Figure 4-17 Fabrication of cable 10S1259

4-10
4.7 Cable Fabrication and Connector Assembling in
Hull Unit (incl. receiver unit)
Assembling 38P connector (CN-C1, CN-C3, CN-C4)
20P connector (CN-C2)
Fabrication of cable for 38P and 20P connectors
CN-C1, CN-C3 CN-C2, CN-C4

200 Anticorrosive L
45 45 Anticorrosive
Shield sheath Shield sheath
40 40

Vinyl sheath
Vinyl sheath
Armor Armor
L = 200 (CN-C2)
250 (CN-C4)

Insulating tape Core Insulating tape


Core

Expose cores; wind Fold back shield


shield around armor. onto armor.

Figure 4-18 Fabrication of cable for 38P and 20P connectors

Assembling the 38P connector

1. Bundle unused wires outside the connector case.


2. Fix the cover 1, noting the cable outgoing direction.
3. Dress the wires and fix the covers 2 and 3. Use a fragment of cable
sheath to fix the wires at the cable clamp.
4. Shorten unused wires and tape their ends with vinyl tape to prevent short Cable outgoing
circuit. direction

Cover 3

Guide Pin A Guide


Pin B
Guide pin

Fragment of
anticorrosive sheath
Cover 1

Position No.

Guide Pin A Guide Pin B


Insulate unused Cover 2 (Large) (Small)
wires with vinyl
tape.
Figure 4-19 How to assemble the 38P connector

4-11
Positioning guide pins

The guide pins of the connector identify the mating receptacle. Position them as shown in the
table below.

Table 4-4 Connectors CN-C1, CN-C2, CN-C3, CN-C4 and guide pins

Connector
CN-C1 CN-C2 CN-C3 CN-C4 Guide Pin Setting Tool
Guide Pin

Guide Pin A (Large) 2 1 1 3

Guide Pin B (Small) 1 1 1 1


Type 10-910-0179-0

Clamping the cable


Cable clamp

Anticorrosive sheath

Figure 4-20 Clamping the cable

Fabrication of cable 10S1261 (connected to terminal board TB-D1


in raise/lower control box)
Shield

35
Anticorrosive
sheath 90

Vinyl tape
M3 (RED) x 12

Fold back shield onto


anticorrosive sheath.

Figure 4-21 Fabrication of cable 10S1261

4-12
Fabrication of cable 10S1259 (connected to terminal board TB-D2
in raise/lower control box)
Armor
3.5sq
x3 M4 (YEL) x 3
30 5 1.25sq
x2 M4 (RED) x 2

70

Figure 4-22 Fabrication of cable 10S1259

4.8 Connection of Transducer Cables


The transducer cables come with connectors attached. Plug the connectors into the proper re-
ceptacles on the receiver unit, referring to the labels on the cables.

1. Connect transducer cables


to the XRS terminal board
referring to labels inside
the receiver unit.
2. Connect ground wires to
slip-on terminals.

P1 Transducer
P2
cable
P3
P4 TD COMMON
P5 Connector
Puller
Ground wire

Transducer cable entrance Note: Use the connector puller


CN-C1
CN-C2
CN-C3

CN-C4

(supplied) whenever
unplugging connectors.
Lead the cables into the receiver unit and
clamp them as shown below.

Cable clamp Seal with putty.

Sleeve Vinyl tape

Figure 4-23 Receiver unit, rear view

4-13
4.9 Connection of Interface Unit CS-120A
With connection of navigator, the Interface Unit CS-120A and electronic fishing equipment,
the function of the CSH-83/84 series is expanded to include true motion presentation, target
lock, echo sounder picture, FNZ marker presentation and digital indication of position, water
temperature and depth. This chapter provides the information for interfacing the CSH-83/84
series with external equipment.

Connections for true motion and target lock


Heading (digital) and speed (200 pulses/nm) data are required to provide the true motion
and target lock functions. Both data are fed to the display unit via Interface Unit CS-120A.

Basically, there are three methods to feed the data:

• Heading data is fed to J205 from A/D Converter AD-100 and the speed pulse data to
J206 from the speed log.
• Both heading and speed data are fed to J207 or J204 from the CIF line of the
CI-30/50/60.
• NMEA signal is fed to J208 (NMEA port) or J207 (CI/NMEA port).

J205 J208
A/D CONV. GYRO NMEA NMEA Signal
AD-100 Heding Data
J207
CI/NMEA NMEA Signal or
CIF Current Signal
ELECTROMAGNETIC INTERFACE
LOG (CS-120A)
J206
LOG
Speed Pulse Data
DISPLAY UNIT
DOPPLER (CSH-830)
SONAR
CURRENT
INDICATOR
CIF 10S1148 J204 CN-A5
DOPPLER (20m MAX) CIF
SONAR J201
CURRENT Heading Data
INDICATOR True Heading Data
Speed Data
Current Data 10S1258

Figure 4-24 Connection of external equipment to Interface Unit CS-120A

Note 1: AD-100 outputs two types of data. 200 ms interval is available.


Note 2: 200 pulses/mile ship’s speed data can be taken from a doppler sonar current
indicator.

4-14
There are six combinations of CIF/NMEA data input.
Combination NMEA port CIF port CI/NMEA port
J208 J204 J207
1 NMEA data - NMEA data
2 NMEA data - CIF current data
3 - CIF data CIF current data
4 NMEA data - -
5 - CIF data -
6 - - NMEA data
Note: NMEA port and CIF port are not fed a data at the same time. Either CIF current data
or NMEA data can be fed to CI/NMEA port.

Speed pulse signal

Do not feed Speed pulse data when speed data is fed from NMEA or CIF port and the
current indicator is chosen as own ship’s navigation data (refer to page 7-5). If they are fed
at the same time, the moving distance data will be doubled.

Receivable Data

• Receivable Sentences from NMEA port


Depth Data:DBT、DPT
Temperature Data:MTW
Position fixing Data:GGA、RMC、GLL、RMA
Speed Data:VTG
Heading Data:VTG、HDT
Current Data:VHW、VDR、CUR
Time Data:ZDA
• Receivable NMEA Sentences from CI/NMEA port
Same data as NMEA port is received. NMEA port has priority.
• Receivable CIF data from CIF port
11:Time Data
21:Dead reckoning Position
24:Loran C fixing Position
28:GPS fixing Position
41:Speed and Heading Data for Dead reckoning
48:Speed and Heading Data from GPS fixing data
56:Current indicator Data for Display
66:Current indicator Heading, Speed, True Course Data
76:Current indicator ID Number, Depth, Current Direction, Current Speed
57:Depth Indicator Depth, Depth Information
58:Temperature Indicator Temperature, Temperature Information
• Receivable CIF data from CI/NMEA port
56:Current indicator Data for Display
66:Current indicator Heading, Speed, True Course Data
76:Current indicator ID Number, Depth, Current Direction, Current Speed

4-15
Connections for ES picture and FNZ markers
To provide echo sounder picture and FNZ markers, connect echo sounder to J203 and net
sonde to J202. The signals applied to J202 and J203 are

J202: Net sonde signal and trigger signal (keying pulse of echo sounder). A white line
signal from an echo sounder may be additionally applied as described on the next
page if the digital depth data is not available on J204.
J203: Echo signal and keying pulse from an echo sounder.

Connection 1: Displaying echo sounder picture


J203
E/S VI-1100A (E/S)

INTERFACE
UNIT
(CS-120A)

Connection 2: Displaying echo sounder picture and FNZ markers by one echo
sounder
FNZ JOINT BOX
(CS-170)
SONDE 1 J202 (SONDE)
J701
(FNZ) TB-1
TB-2
SONDE
2
(FNZ) TB-1
J203 (E/S)
J705 TB-2
SONDE
(FNZ) 3 INTERFACE
UNIT
(CS-120A)
E/S VI-1100A

This method is used when the net sonde is installed and both echo sounder and net sonde
signals are taken from the same echo sounder. The net sonde signal is applied to both J202
and J203.

Connection 3: Displaying echo sounder picture and FNZ markers by separate


echo sounders
FNZ JOINT BOX
(CS-170)
SONDE 1 J202 (SONDE)
J701
(FNZ) TB-1
TB-2
SONDE
2
(FNZ) J203 (E/S)
J705
SONDE
(FNZ) 3 INTERFACE
UNIT
(CS-120A)
E/S VI-1100A

E/S VI-1100A

4-16
Connections for digital indication of position,
water temperature and depth
The data for these readouts are taken from the equipment shown in the table below and
input to J208 or J204. Input to J208 if the data is NMEA format, or to J204 if the data is CIF
format.
Data Data Source
Position Loran C navigator, GPS navigator
Temperature Indicator T-2000/TI-20, nav equipment or
Water Temperature
color video sounder connected to temperature sensor
Depth Color video sounder
Note: When a sounder which has digital depth data output is not available, the white line
signal of a paper recording echo sounder can be used to provide digital depth
readout. Connect the echo sounder as shown below or as shown in connection 2 or
3 on previous pages and operate the echo sounder front panel controls so that the
white line is effected on the seabed contour.
Trigger (KP)
J202 (SONDE)
white line sig.

J701
E/S VI-1100A CS-170 J203 (E/S)
J705 TB-1
INTERFACE
UNIT
(CS-120A)

Wiring
Connect referring to the Interconnection Diagram at the back of this manual.

4-17
Assembling 10P and 7P connectors

10P Connector (SRCN6A16-10P) J202 (FNZ), J204 (CIF), J205 (GYRO), J207 (CI)
8cm
1cm 2cm
BRAIDED
SHIELD
m
3m
VINYL SHEATH VINYL SHEATH
(OUTER) (INNER)

EARTH WIRE
SOLDER UNUSED CORES
AND EARTH TO
BRAIDED SHIELD
CLAMP FIXING SCREW

SET SCREW
CLAMP
SOLDERING WIND SHIELDING TAPE

VINYL SHEATH ARMOR


(OUTER)

CONNECTOR CASE

SOLDERING-SIDE

WIND VINYL TAPE CLAMP SHIELDING TAPE


WITH CONNECTOR CLAMP
FOR GROUNDING.

7P Connector (SRCN6A16-7P) J203 (E/S)

2cm
BRAIDED
SHIELD

VINYL SHEATH
SOLDERING-SIDE

EARTH
SOLDER UNUSED CORES WIRE CLAMP FIXING SCREW
AND EARTH WIRE TO SET
BRAIDED SHIELD
CLAMP SCREW

VINYL SHEATH

CONNECTOR CASE
WIND VINYL TAPE

Figure 4-30 Assembling 10P and 7P connectors

4-18
4.10 Connection of Sub-Display Unit (option)
The Sub-Display Unit CSH-236 controls the sonar from a remote location, and its outline di-
mensions and control panel layout are identical to the display unit. One sub-display unit can be
connected to three display units.

Note: The Sab-Display Unit can be connected to CSH-83 only.

Connections
Refer to the interconnection diagram on page S-1 and the connector assembling/cable fabrica-
tion procedure on page 4-4.

Note: A sub-display unit may not be connected to different models (for example, CSH-73 and
CSH-24).

DIP switch setting


Set DIP switch S1 on RDCB board 10P6724 in the sub-display unit referring to the figure and
table below.

Figure 4-31 Sub-display unit, cover opened

Table 4-6 DIP switch S1 setting on RDCB board

SW
Used for Description
No.
1 Display unit on CH-1 ON: Turning on the sub-display unit automatically turns on
2 Display unit on CH-2 the display unit.
3 Display unit on CH-3
4 Display unit on CH-1 ON: Turning on the display unit automatically turns on the
5 Display unit on CH-2 sub-display unit.
6 Display unit on CH-3 OFF: Sub-display unit is turned on.
7 Remote ON/OFF Used in remote display unit. Set to ON in sub-display unit.

8 Not used

Note: You may wish to have both the display unit and a sub-display unit turn on when one is
turned on. To do this turn on both #1 and #4.
4-19
4.11 Connection of Remote Display Unit (option)
Three display units may be connected to one remote display unit. Operating controls provided
on the remote display are power on/off switch, brilliance control and channel selector, which
selects a display unit.

Note: The Remote-Display Unit can be connected to CSH-83 only.

Connections
Refer to interconnection diagram on page S-1 and cable fabrication/connector assembling pro-
cedure on page 4-11.

Note: The display unit has two ports: one for sub-display unit and the other for remote display
unit. When there is no sub-display unit, both ports can be connected to remote display units.

Set DIP switch S1 on RDCB board 10P6724 in the remote display unit referring to the table and
figure below.

Figure 4-32 Remote display unit, cover opened

Table 4-7 DIP switch S1 setting on the remote display unit

SW
Used for Description
No.
1 Display unit on CH-1 Not used.
2 Display unit on CH-2
3 Display unit on CH-3
4 Display unit on CH-1 Turn on when display unit is connected; turn OFF when not
5 Display unit on CH-2 connected.
6 Display unit on CH-3
7 Remote ON/OFF ON: Remote display unit turns on when a display unit is
turned on. Remote display turns off when all display
units are turned off.
OFF: Remote display is turned on/off by its ON/OFF switch.

Note: The remote display cannot be turned on unless a


display unit is turned on.
8 Not used

4-20
4.12 Synchronizing Transmission with Other Sonars or
Echo Sounders
You may synchronize transmission with other sonars or echo sounders.

Connections
a) For current driven KP b) For voltage driven KP

Display unit Display unit


CN-A6 CN-A6

EXT KP H <Z< E/S EXT KP H <MM< E/S


EXT KP C <AA< Sonar GND <TT< Sonar

a) Current driven KP output b) Voltage driven KP output

Display unit Display unit


CN-A6 CN-A6

EXT KP H <DD< E/S E/S


EXT KP C <EE< Sonar INT KP H <KK< Sonar
GND <RR<

Figure 4-33 Connections for synchronizing transmission with other sonars or echo sounders

Menu setting
Set polarity of the KP on the INIT/SET menu. Set transmission cycle to “0” on data setting
window. Refer to the operator’s manual for further details.

4-21
4.13 Interlocking Operation with Other Sonars
Functions (range, tilt, fish marks, etc.) and remote control may be mutually interlocked with
those on other sonars (CSH-23/24/73/83/84). For example, if the range is interlocked, changing
the range in one sonar automatically sets the other sonar to the same range. The functions to be
interlocked can be selected on the SYSTEM menu. See the operator’s manual for further de-
tails.

Connections for interlocking functions


Two sonars

Sonar 1 Sonar 2

CN-A4 CN-A4
TD H A E RD H
P
TD C B F RD C
RD H E A TD H
P
RD C F B TD C

Figure 4-34 Connections for interlocking two sonars

Three sonars

TD RD
Sonar 1 Sonar 2
RD TD

TD RD

Sonar 3

Figure 4-35 Connections for interlocking three sonars

DIP switch setting

Set ID code with DIP switches #1 thru #3 on the display unit. Any code is acceptable, provided
that it is not the same as that set on the other sonar. For how to access the DIP switches see page
7-3.

4-22
Connections for interlocking remote control
A single remote control box can control three display units. Connect it to the display units as
shown below.

Connect same pin numbers. Connect same pin numbers.

CN-A13 CN-A14 CN-A13 CN-A14 CN-A13 CN-A14

REMOTE CONTROL

CONE Board on CONE Board on CONE Board on


DISPLAY UNIT 1 DISPLAY UNIT 2 DISPLAY UNIT 3

Figure 4-36 Connections for remote control of multiple display units

4-23
5. CHANGING POWER SPECIFICATIONS
The display unit is set at the factory for connection to ship’s mains of 100 VAC. To power it by
110 VAC or 220 VAC, use step-down transformer PT-400, change the transformer taps on the
power unit as below and connect the ship’s mains directly.

The unit is set at the factory


for 100 VAC.

0V 90V 100V 110V 0 90V 100V 110V

Ship's
Mains
For 100 VAC Ship's Mains

0V 90V 100V 110V 0 90V 100V 110V

Ship's
Mains
For 110 VAC Ship's Mains

0V 90V 100V 110V 0 90V 100V 110V

Ship's
F Photo No.1747
Mains
For 220 VAC Ship's Mains
POWER UNIT

Figure 5-1 Changing tap connections on the power unit

5-1
6. INSTALLATION OF FRP RETRACTION TANK

6.1 Before Beginning the Installation


Note the following before installing the FRP tank:
• Use only the tank supplied.
• Follow the instructions in this chapter.
• If the owner of the equipment elects to use a shipyard-prepared FRP tank, FURUNO will
assume no responsibility for any damage caused by water leakage. If the shipyard supplies
the FRP tank, do the following:
• The finished surface of the tank flange must be within 0.5 mm of horizontal.
• Use sealant recommended by shipyard.

Table 6-1 Contents of FRP retraction tank installation kit

Name Type Code No. Qty


FRP Retraction Tank SHG-0001 660-800-011 1
Waterproofing Gasket SHH-0003-1 660-800-031 1
Three Bond Sealant 1101 200 g 000-854-101 1

6.2 Installation of the FRP Retraction Tank


Fasten the hull unit to the retraction (after installing the retraction tank) as follows.

1. Clean the surface of the tank flange. Coat the flange with about 1 mm thickness of sealant
(Three Bond 1101, supplied).
Note: Use only the sealant supplied.
Sealant
2 mm 1 mm

100 mm

FRP Tank

Figure 6-1 Coating the tank flange with sealant (supplied)

2. Lay the waterproofing gasket on the tank flange and coat the gasket with about 1 mm thick-
ness of sealant.

6-1
Sealant
Waterproofing
gasket

Figure 6-2 Laying the waterproofing gasket on the tank flange

3. Orient the bow mark (arrow) on the hull unit flange toward ship’s bow. (If the mark cannot
be perfectly oriented toward ship’s bow adjust heading after installation as shown in the
next chapter.)
Hull unit flange

Ship's
bow

Figure 6-3 Orienting hull unit flange toward ship’s bow

4. For the 1200 mm stroke hull unit, insert insulation gaskets in each of the 11 holes for stud
bolts on the tank flange. (Do this before setting the hull unit to the retraction tank.)

Insulation
gasket

Figure 6-4 Inserting insulation gasket in tank flange

5. Before setting the hull unit on top of the retraction tank, observe the following cautions:
• Clean the hull unit flange to make sure no foreign material has fallen into the retraction
tank.
• Confirm that waterproofing gasket is in place.

6-2
Bolt
hole

Figure 6-5 Tank flange

6. Set the hull unit on top of the retraction tank. Pass flat washer onto hex bolt and insert them
in stud bolt hole from the top of the hull unit flange. At the retraction tank, fasten the bolt
with insulation gasket, flat washer, spring washer and nut, in the order shown in the figure
below.

Hex bolt
Flat washer

Insulation gasket
Hull unit flange

Tank flange
Insulation gasket

Flat washer
Spring washer
Nut

Figure 6-6 Fastening the hull unit to the retraction tank

7. Install stays from the top of the hull unit, using the eye bolts.

Stay

Stay

Post

Figure 6-7 Installing stays on the hull unit

6-3
7. ADJUSTMENT AND CHECK

7.1 Hull Unit Check


1. Press the ON switch to turn on the equipment. Con-
firm that the lamps above the ON and c switches POWER TRANSDUCER

light.
OFF ON
2. Confirm that the 5V and UP lamps on the raise/
lower control box are lit.
3. Remove the cover of the raise/lower control box
and check the following voltages:
Figure 7-1 Display unit front panel
Terminal Terminal No. Voltage
TB-D1 7–8 +12 V
1–2 100 VAC
TB-D2 2–3 100 VAC
1–3 200 VAC

4. In the raise/lower control box, turn the TEST/NOR-


MAL switch to TEST. Press the d switch to con-
firm that the transducer lowers. Also, while the
transducer is being lowered, check that the MD LED
lights when the MD L. SW kicks. Note that the MD
L. SW does not stop the transducer when the TEST/
NORMAL switch is in the TEST position. Figure 7-2 Raise/Lower control box
5. Press and release the d switch. Confirm that the transducer stops at the moment the switch
is released.
6. Press the d switch again. Confirm that the transducer stops at the moment the lower limit
switch kicks.
7. Confirm that the c switch operates in a similar manner.
8. Check that LEDs on the panel of the raise/lower control box light as follows:
1) UP, MD and DN LEDs light when corresponding limit switch kicks.
2) UP and DOWN LEDs light while UP and DOWN switches are pressed and extinguish
when switches are released.

9. Set the TEST/NORMAL switch to NORMAL.


10. At the display unit, press the d (mid position) switch. Confirm that the lamp above the
switch blinks while the transducer is being lowered, a short beep sounds when the mid limit
switch kicks, and the lamp lights when the transducer is fully lowered.

7-1
11. Press the d switch. Confirm that the lamp above the switch blinks while the transducer is
being lowered, a short beep sounds when the mid limit switch kicks, and the lamp lights
when the transducer is fully lowered.
12. Press the c switch. Confirm that the lamp above the switch blinks while the transducer is
being raised, a short beep sounds when the mid limit switch kicks, and the lamp lights when
the transducer is fully raised.
13. Press the OFF switch. Confirm that the transducer is completely retracted and then the
power is turned off.
14. With the transducer lowered, confirm that the transducer is raised when c or OFF is pressed.

7.2 Heading Adjustment


When the arrow on the flange of the hull unit cannot be directed toward ship’s bow adjust the
heading so an echo which is dead ahead appears dead ahead on the display.

1. Locate a target in the bow direction (buoy, for example) and display it on a near range. If the
target appears at 12 o’clock the heading alignment is correct and no further adjustment is
necessary. If it is not go to step 2.
Bow

If target's on-screen
Buoy position is right of ship's
bow, for example, hull unit
e heading is skewed to left.

Figure 7-3 Heading adjustment

2. Turn on the power while pressing and holding down the MENU key. The INIT SET/TEST
menu appears.

INIT SET/TEST MENU

Select item with dc[ \ keys and press MENU key.


Press END key to close menu.

HEADING ADJ BAUD RATE EXT KP UNIT/LANGUAG

SELF TEST ECHO TEST E/S NET REC DEFAULTS

OTHERS

Figure 7-4 INIT SET/TEST menu

3. Select HEADING ADJ.

7-2
INIT SET/TEST MENU

Select item with dc[ \ keys and press MENU key.


Press END key to close menu.

HEADING ADJ 359° Setting range: 0° to 359°

Figure 7-5 HEADING ADJ menu

4. Enter heading correction with [ or \, referring to the example in the table below for
guidance.

Target Location Correction Setting


Target displaced 30° to port Set to 30°.
Target displaced 30° to starboard Set to 330°.

7.3 DIP Switch Setting in the Display Unit


Set the DIP switch in display unit, referring to the table
shown below.

1. Unfasten six screws on the main panel.


2. Draw out the main panel and unplug four connectors.
3. Set DIP switch referring to the table below.

DISPLAY UNIT

Figure 7-6 Dismounting the main panel

7-3
DSW Board (10P6722F)

Item SW No. Setting


ID Code for 1 Set ID code for interlock operation of CSH-23/24/73/83/84 sonar.
Interlock Any code is acceptable unless it is used in other interlocked
2
Function sonars.
3
Unit Code 4 OFF ON ON OFF ON
5 OFF OFF ON OFF ON
6 OFF OFF OFF ON ON
CSH-58 CSH-53 CSH-23/24 CSH-73/ CSH-23F/23FL/
(28 kHz) (55 kHz) 83/84 24F/24FL
Unit
CSH-53
(28 kHz)
EEPROM Check Check
7 ON OFF
Check OFF ON
Stand Alone 8 For factory use. Set to ON always.

PND Board (10P6714)


Item SW No. Setting
Display unit setting 3* OFF For 21” CRT display unit
(CSH-24/24F/24FL/84)
ON For 15” CRT display unit
(CSH-23F/23FL/24F/24FL)
*: Set to OFF for the Processor unit.

7-4
7.4 Setting and Adjustment of the Interface Unit
CS-120A
DIP switch setting
Navigation data and fishing data input from external equipment can be turned on or off by
DIP switches DP-1 and DP-2 on CPU II board 10P6871 in the Interface Unit CS-120A.
DP-2 CI/NMEA port Input format
ON
Input format S1
1 2 3 4

CIF (Factory Setting) OFF


NMEA ON

Standard Changed the register R78 (47Ω) to 470Ω on pcb 10P0047


Setting when NMEA is selected.
-NMEA: 470Ω
-CIF: 47Ω

Interface board
(10P0047)

R78

DP-1
ON Own ship's navigation data (Gyrocompass, Speed log or Current indicator etc.)
1 2 3 4 5 6 7 8

Input Device S1 S2Select navigation device which feeds


navigation data for drawing ship's track
Gyrocompass, Sppeed log OFF OFF
by S1 and S2.
GPS or DR *1 ON OFF
Current indicator OFF ON
Gyrocompass, GPS *2 ON ON
*1: GPS ship's speed/heading data from NMEA or CIF line, or dead reckoning speed/
heading data are used. Take care that heading data may have error if the speed is
next page lower than 0.2 kts.
*2: Courseline is plotted by using CIF or NMEA format speed data and Gyrocompass data.
Fix to "OFF" Speed log is set by using GPS or Current Indicator.
Latitude/Longitude
Input Device S3
Loran C OFF
GPS or DR * ON

Own ship's position data is selected with S3.


*: Data from GPS or DR is used (GPS has priority).

7-5
DP-1
ON Talker check (only for NMEA signal)

1 2 3 4 5 6 7 8
S4
Talker is checked. OFF
Talker is not checked. ON
Talker of GP, SD, VD, etc. is checked.

Depth (Echo sounder, Color Video Sounder, etc.)


Input Device S5
Echo Sounder * OFF
CIF or NMEA line ON
Depth data is selected with S5.
*: Use this position for white line pulse when the depth data is taken from
an echo sounder. However late model FURUNO echo sounders do not
output white line pulse. Normally set to ON.

Interface unit (10P0047) adjustment


If the E/S picture on the screen does not have the desired coloration, perform the
adjustment as follows with the preset potentiometers on the I/O board in the interface unit.

R27
Interface board
R36
(10P0047)
R55
R56
S01
S02
Setting for DIP switch

S01: The FNZ marker is plotted on the echo sounder picture with this
switch turned on when FNZ marker signal is fed to External Interface.
Factory setting is the “ON” position.

S02: Selects the signal mode (AC or DC) according to the combined echo
sounder connected. Factory setting is the “AC” position.

7-6
Adjustment of signal level (R36, R56)
1. Set the MODE switch to E/S.
2. Turn the potentiometer R36 to suppress a noise, and the potentiometer R56 so that the
color gradation of the E/S picture on the screen appears similar to the intensity
gradation of the combined E/S echogram.

Adjustment of white line inhibit time (R27)


In case digital depth data is not combined with the CS-120A, the white line signal from the
echo sounder is used for depth information. Potentiometer R27 cancels the white line pulse
for about 10 ms after transmission to avoid false depth indication caused by unwanted
noise in short ranges. Readjustment of potentiometer R27 is not required as long as
CSH-83/84 series indicates the correct depth. If does not, however turn R27 to the right.

Adjustment of white line output level (R55)


Improper setting of potentiometer R55 causes the seabed line to be painted in deep blue
due to the white line pulse. Adjust it so that the seabed line is painted in same color as
seabed.

Priority for data


The priority between ports, the category of data or formats is as follows. “1” has the highest
priority.

Basic priority
1. NMEA data > CIF data
2. NMEA data: NMEA port data > CI/NMEA port data
3. CIF data: CI/NMEA port data > CIF port data

Heading priority
1. Heading data from GYRO port
2. GP-HDT from NMEA port (GP-HDT: HDT sentence with talker GP)
3. GP-HDT from CI/NMEA port
4. VD-VHW from NMEA port
5. VD-VHW from CI/NMEA port
6. VD-CUR from NMEA port
7. VD-CUR from CI/NMEA
8. CIF signal <66> from CI/NMEA port
9. CIF signal <66> from CIF port

GPS fixing position priority


Latitude and Longitude are set to GPS/DR with S3 on the DIP switch DP-1.
1. GP-GGA from NMEA port
2. GP-GGA from CI/NMEA port
3. GP-RMC from NMEA port
4. GP-RMC from CI/NMEA port
5. GP-GLL from NMEA port
6. GP-GLL from CI/NMEA port
7. <28> from CIF port

LC fixing position priority


Latitude and Longitude are set to LC with S3 on the DIP switch DP-1.
1. LC-RMA from NMEA
2. LC-RMA from CI/NMEA
3. <24> from CIF port

7-7
Depth priority
Depth is set to CIF/NMEA with S5 on the DIP switch DP-1.
1. SD-DPT from NMEA port
2. SD-DPT from CI/NMEA port
3. SD-DBT from NMEA port
4. SD-DBT from CI/NMEA port
5. <57> from CIF port

Ship’s movement data priority (data from GPS/DR)


Ship’s movement data is set to GPS·DR with S1/S2 on the DIP switch DP-1
1. GP-VTC from NMEA port
2. GP-VTC from CI/NMEA port
3. GP-RMC from NMEA port
4. GP-RMC from CI/NMEA port
5. <48> from CIF port
6. <41> from CIF port

Ship’s movement data priority (data from Current indicator)


Ship’s movement data is set to Current indicator with S1/S2 on the DIP switch DP-1
1. VD-VTG from NMEA port
2. VD-VTG from CI/NMEA port
3. VD-VHW from NMEA port
4. VD-VHW from CI/NMEA port
5. CIF signal <66> from CI/NMEA port
6. <66> from CIF port

Ship’s movement data priority (data from Gyro/Navigation)


Ship’s movement data is set to Gyrocompass/navigation with S1/S2 on the DIP switch
DP-1.
1. GP-VTG from NMEA port
2. GP-VTG from CI/NMEA port
3. GP-RMC from NMEA port
4. GP-RMC from CI/NMEA port
5. LC-VTG NMEA port
6. LC-VTG from CI/NMEA port
7. LC-RMA from NMEA port
8. LC-RMA from CI/NMEA port
9. <48> from CIF port
10. <44> from CIF port

Current data (multi layer) priority


1. VD-CUR from NMEA port
2. VD-CUR from CI/NMEA port
3. CIF signal <76> from CI/NMEA port
4. <76> from CIF port

Current data (single layer) priority


1. VD-VDR from NMEA port
2. VD-VDR from CI/NMEA port
3. CIF signal <56> from CI/NMEA port
4. <56> from CIF port

7-8
REMOTE
CONTROL BOX *
DISPLAY UNIT
RECEIVER UNIT

RAISE/LOWER
CONTROL BOX INTERFACE UNIT

10S1258-1

10S1277, 7 m
*3 (Max. 20 m)

DPYC-1.5
10S1259
INVERTER
interconnection diagram are as follows.

(Max. 20 m)
10S1261 (Max. 5 m) TR-2435

DC 20 V AC 100 V
- +
POWER UNIT

8-1
DPYC-1.5

24 VDC

10S1258-1
10S1260 (Max. 40 m) (Max. 20 m)
10S1260 (Max. 20 m)
DPYCY-4 10S1258-1
10S1259 (Max. 20 m)
Notes:
TR INVERTER CURRENT LIMITER BOX
limiter box CSH-1400. (All units are optional supply.) The system diagram and

*: For blackbox type, the processor


TR-24100 CSH-1400 unit is provided instead of the
display unit.
8. WHEN SHIP’S MAINS IS 24 VDC

24 VDC
When the ship’s mains is 24 VDC, use DC/AC inverter unit TR-2435, TR-24100 and current
Transmitter Unit
CSH-810
TB-B1
1 2 3 4 5 6

RED BLK WHT BRN BLK

P
Display Unit
CSH-830
CSH-8400
Power Unit
CSH-880 CN-A15
TB-E1
*DPYCY-3.5 *DPYCY-3.5 3
CN-E1 2 1
2
2
1
3
TR Inverter
4 TR-24100
5 RED
6 BLK
7 WHT 100 VAC 100 VAC
8 BRN OUTPUT OUTPUT
P
9 BLK
1 kVA 350 VA
10 RED
11 BLK INPUT INPUT
12 WHT 24 VDC 24 VDC
13 BRN - + - +
P
14 BLK
15 Inverter
10S1259

10S1259

16 TR-2435

*DPYCY-5.5
*DPYCY-3.5

P P
RED BLK WHT BRN BLK RED BLK WHT BRN BLK
24 VDC
1 2 3 4 5 6 1 2 3 4 5 6 Ship s mains
TB-01 TB-02
Current Limiter Box CSH-1400 *: Local supply

Figure 8-2 Connection with 24 VDC ship’s mains

8-2
9. PROCESSOR UNIT CSH-835
(BLACKBOX TYPE FOR CSH-83)

9.1 Installing the Unit


When selecting a mounting location, consider the following conditions:
• Place where operating personnel are able to control the unit easily while observing the
fishing ground or the area surrounding the vessel.
• Place not exposed to direct sunlight, water splashes or hot air.
• Place where maintenance and ventilation clearance shown in the outline drawings is
ensured.
• Observe the compass safe distances shown on page i to prevent interference to a
magnetic compass.

Mounting procedure
1. Remove the mounting base by unscrewing the two bolts at the front bottom.
2. Fix the mounting base to the table or deck by using six self-tapping screws 6x20
(supplied).
3. Place the unit on the mounting base, slide it forward and then fasten it to the mounting
base with two bolts.

(133)
140±1
220

°)0
(9
7

6-φ8 Fixing holes


37 210±1 210±1

Remove two bolts

Processor unit Top view

9-1
9.2 Monitor
Use a commercially available monitor having the specifications shown below.
• Signal: Analog RGB, 0 – 0.9 V, Positive, 75 Ω
• Synchro. signal: Horizontal, TTL level, 31.687 kHz±4 Hz, 75 Ω
Vertical, TTL level, 60.111 Hz±0.007 Hz, 75 Ω
• Resolution: VGA, 664 x 481

Mount the monitor in portrait orientation. Note that FURUNO monitor model MU-151C can be
used in portrait orientation.

9.3 Connecting cables


Fabricate the cables as shown in the section “4.4 Cables Fabrication and Connect Assembling
in Display and Interface Units.” Connect the cables, referring to the interconnection diagrams at
the back of this manual.
Port for monitor

Cable entrance

DISPLAY
RGB port panel R

B D-sub
15P
H
Power supply port
V
BNC

FUSE
5A

H C
2 3

100 VAC
50/60Hz
2A 1
GND

Ground terminal

Processor unit (rear panel)


Protective earth
Attach protective earth cable (IV-8sq, shipyard supply) between the GND terminal of the
processor unit and ship’s body.

CAUTION
Securely attach protective earth
to the ship's body.
The protective earth is required
to prevent electrical shock.

9-2
Connectors for Monitor
There are two kinds of video signal ports: D-sub connector (default) and BNC connectors.
• D-sub: Use interconnection cable 3COX-2P-6C (5 m or 10 m) or equivalent commercially
available cable.
• BNC connector: Use five 75 Ω coaxial cables (shipyard supply). The coaxial cables are
preferred in case of longer than 10 m cable run between the processor unit and monitor.

The following modification is required to use the BNC connectors.


1. Dismount the RGB port panel at the rear of the processor unit.
2. Confirming the label attached to each BNC connector, connect each connector to its
corresponding port.
3. Mount the RGB port panel.
CONE board (10P6711)

Screw (4 pcs)

J21
BNC connector

R
G
Replace each
B BCN connector
H to the same
label port.
V

RGB port panel

J3

Processor unit (right side, cover removed)

9-3
A-1
PACKING LIST 10CJ-X-9851 -1 1/1

CSH-235/235K/235F/535/585/735/835
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT
操作制御部 CSH-235
1
PROCESSOR UNIT
000-070-191 **
予備品 SPARE PARTS
予備品 SP10-03201
1
SPARE PARTS
006-030-590
工事材料 INSTALLATION MATERIALS
工事材料 CP10-06301
1
INSTALLATION MATERIALS
006-030-600

1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL.

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)


10CJ-X-9851
A-2

CODE NO. 006-030-590 10CJ-X-9301 -1 1/1


TYPE SP10-03201 BOX NO. P
SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL

DWG. NO. QUANTITY REMARKS/CODE NO.


ITEM NAME OF OR WORKING
NO. PART OUTLINE
TYPE NO. PER PER SPARE
SET VES
ヒューズ FGBO-A 5A
AC125V
1 FUSE 3

000-549-064

MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 10CJ-X-9301 1/1

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)


A-3

CODE NO. 006-030-600 10CJ-X-9401 -0


TYPE CP10-06301 1/1

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
+トラスタッピンネジ 1種 6X20 SUS304
1 6
SELF-TAPPING SCREW
CODE NO. 000-802-084

コネクタ(NCS) NCS-253-P
2 1
CONNECTOR(NCS)
CODE NO. 000-506-503

10CJ-X-9401

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-4

CODE NO. 000-066-918 10BY-X-9301 -8 1/1


TYPE SP10-02000 BOX NO. P
SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL

QUANTITY REMARKS/CODE NO.


DWG. NO.
ITEM NAME OF WORKING
NO. OUTLINE OR
PART PER PER SPARE
TYPE NO.
SET VES
ヒューズ FGAO 10A 指示装置用
AC125V
1 FUSE 1 5 FOR DISPLAY UNIT

000-126-852
ヒューズ FGMA 2A AC125V 指示装置用

2 FUSE 2 4 FOR DISPLAY UNIT

000-126-841
ヒューズ FGMA 1A AC125V 指示装置用

3 FUSE 1 2 FOR DISPLAY UNIT

000-126-840
ヒューズ FGMA 3A 指示装置用
125V(UL)
4 FUSE 1 2 FOR DISPLAY UNIT

000-111-848
管入りヒューズ F-7165 20A 指示装置用
AC250V
5 FUSE 1 2 FOR DISPLAY UNIT

000-547-022
XHコネクタ組品 10-286(15P) 受信装置用

6 XH.CONNECTOR 1 1 FOR RECEIVER UNIT


ASSY.
006-902-750
XHコネクタ組品 10-285(10P) 受信装置用

7 XH.CONNECTOR 1 1 FOR RECEIVER UNIT


ASSY.
006-902-740
ヒューズ FGBO-A 2A 送信装置用
AC125V
8 FUSE 16 20 FOR TRANSMITTER UNIT

000-549-062
コネクタ抜き工具 10-038-3901-0 受信装置用

9 CONNECTOR 1 FOR RECEIVER UNIT


PULLER
100-075-230

MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 1/1


C1290-P01-J
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-5

CODE NO. 000-070-211 10CL-X-9301 -0 1/1


TYPE SP10-03600 BOX NO. P
SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL

QUANTITY REMARKS/CODE NO.


DWG. NO.
ITEM NAME OF WORKING
NO. OUTLINE OR
PART PER PER SPARE
TYPE NO.
SET VES
管入りヒューズ F-7165 20A 指示装置用****
AC250V
1 FUSE 2 FOR DISPLAY UNIT

000-547-022
XHコネクタ組品 10-285(10P) 受信装置用

2 XH.CONNECTOR 1 FOR RECEIVER UNIT


ASSY.
006-902-740
XHコネクタ組品 10-286(15P) 受信装置用

3 XH.CONNECTOR 1 FOR RECEIVER UNIT


ASSY.
006-902-750
コネクタ抜き工具 10-038-3901-0 受信装置用

4 CONNECTOR 1 FOR RECEIVER UNIT


PULLER
100-075-230
ヒューズ FGBO-A 2A 送信装置用
AC125V
5 FUSE 20 FOR TRANSMITTER UNIT

000-549-062

MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 10CL-X-9301 1/1

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)


A-6

CODE NO. 006-934-000 10BY-X-9401 -7


TYPE CP10-03010 1/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(SRCN) SRCN2A16-7P 外部インターフェース工材用
FOR INTERFACE UNIT
1 1
CONNECTOR(SRCN)
CODE NO. 000-508-652

コネクタ(8016) 00-8016-038-313761HV 外部インターフェース工材用


FOR INTERFACE UNIT
2 1
CONNECTOR(8016)
CODE NO. 000-127-234

貼りマーク.J201. 10-018-5022 外部インターフェース工材用


FOR INTERFACE UNIT
3 1
STICKER.J201.
CODE NO. 181-850-220

コネクタ(54) 54-038-000-601/SC 外部インターフェース工材用


FOR INTERFACE UNIT
4 1
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 外部インターフェース工材用


FOR INTERFACE UNIT
5 38
CONTACT PIN (8017)
CODE NO. 000-519-542

アース線組品 CS-120-C 外部インターフェース工材用


FOR INTERFACE UNIT
6 1
GROUNDING WIRE
CODE NO. 006-937-660

コネクタ(RM) RM15TP-2PA 外部インターフェース工材用


FOR INTERFACE UNIT
7 1
CONNECTOR(RM)
CODE NO. 000-503-314

コネクタ(SRCN) SRCN6A16-10P 外部インターフェース工材用


FOR INTERFACE UNIT
8 4
CONNECTOR(SRCN)
CODE NO. 000-508-663

コネクタ(SRCN) SRCN6A16-7P 外部インターフェース工材用


FOR INTERFACE UNIT
9 1
CONNECTOR(SRCN)
CODE NO. 000-508-662

コネクタ(8016) 00-8016-038-313761HV 指示装置工材用  


FOR DISPLAY UNIT
10 1
CONNECTOR(8016)
CODE NO. 000-127-234

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1290-M01-H
A-7

CODE NO. 006-934-000 10BY-X-9401 -7


TYPE CP10-03010 2/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
クーラーパテ 200Gイリ シロイロ 指示装置工材用  
FOR DISPLAY UNIT
11 2
COOLER PUTTY
CODE NO. 000-807-621

イラックスチューブ(A) 4.0X0.3 キイロ *5CM* 指示装置工材用  


FOR DISPLAY UNIT
12 1
INSULATION TUBE(A)
CODE NO. 000-100-923

コネクタ(NCS) NCS-252-P 指示装置工材用  


FOR DISPLAY UNIT
13 1
CONNECTOR
CODE NO. 000-506-501

コネクタ(NCS) NCS-253-P 指示装置工材用  


FOR DISPLAY UNIT
14 1
CONNECTOR(NCS)
CODE NO. 000-506-503

アース板 WEA-1004-0 指示装置工材用  


FOR DISPLAY UNIT
15 1
COPPER STRAP
CODE NO. 500-310-040

コネクタ(8016) 00-8016-020-313-703V 受信装置工材用  


FOR RECEIVER UNIT
16 1
CONNECTOR
CODE NO. 000-111-143

P貼りマーク.11. 10-026-0619-0 受信装置工材用  


FOR RECEIVER UNIT
17 1
P STICKER.11.
CODE NO. 100-014-880

コネクタ(54) 54-038-000-601/SC 受信装置工材用  


FOR RECEIVER UNIT
18 3
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 受信装置工材用  


FOR RECEIVER UNIT
19 114
CONTACT PIN (8017)
CODE NO. 000-519-542

ホールプラグ NO.4567 受信装置工材用  


FOR RECEIVER UNIT
20 4
HOLE PLUG
CODE NO. 000-800-729

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1290-M02-H
A-8

CODE NO. 006-934-000 10BY-X-9401 -7


TYPE CP10-03010 3/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
アース板 WEA-1004-0 受信装置工材用  
FOR RECEIVER UNIT
21 1
COPPER STRAP
CODE NO. 500-310-040

シールドスリーブ ZSK-06HF 0.055M 受信装置工材用  


FOR RECEIVER UNIT
22 20
SHIELD SLEEVE
CODE NO. 000-809-085

圧着端子 FV1.25-3.7 アカ 上下装置用


FOR HULL UNIT
23 15
CRIMP-ON LUG
CODE NO. 000-108-699

圧着端子 FV1.25-M4 アカ 上下装置用


FOR HULL UNIT
24 5
CRIMP-ON LUG
CODE NO. 000-536-715

圧着端子 FV5.5-4 上下装置用


FOR HULL UNIT
25 5
CRIMP-ON LUG
CODE NO. 000-538-123

貼りマーク 10-026-5002-0 送振装置工材用   


FOR TRANSMITTER UNIT
26 1
STICKER
CODE NO. 100-004-870

コネクタ(54) 54-038-000-601/SC 送振装置工材用   


FOR TRANSMITTER UNIT
27 3
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 送振装置工材用   


FOR TRANSMITTER UNIT
28 120
CONTACT PIN (8017)
CODE NO. 000-519-542

圧着端子 FV1.25-M4 アカ 送振装置工材用   


FOR TRANSMITTER UNIT
29 5
CRIMP-ON LUG
CODE NO. 000-536-715

圧着端子 FV5.5-4 送振装置工材用   


FOR TRANSMITTER UNIT
30 5
CRIMP-ON LUG
CODE NO. 000-538-123

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1290-M03-H
A-9

CODE NO. 006-934-000 10BY-X-9401 -7


TYPE CP10-03010 4/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
ホールプラグ NO.4567 送振装置工材用   
FOR TRANSMITTER UNIT
31 4
HOLE PLUG
CODE NO. 000-800-729

アース板 WEA-1004-0 送振装置工材用   


FOR TRANSMITTER UNIT
32 1
COPPER STRAP
CODE NO. 500-310-040

貼りマーク.1. 10-026-7018-0 電源装置用     


FOR POWER UNIT
33 1
STICKER.1.
CODE NO. 100-008-630

コネクタ(54) 54-038-000-601/SC 電源装置用     


FOR POWER UNIT
34 1
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 電源装置用     


FOR POWER UNIT
35 38
CONTACT PIN (8017)
CODE NO. 000-519-542

圧着端子 FV1.25-M4 アカ 電源装置用     


FOR POWER UNIT
36 6
CRIMP-ON LUG
CODE NO. 000-536-715

圧着端子 FV5.5-4 電源装置用     


FOR POWER UNIT
37 15
CRIMP-ON LUG
CODE NO. 000-538-123

ホールプラグ NO.4567 電源装置用     


FOR POWER UNIT
38 4
HOLE PLUG
CODE NO. 000-800-729

アース板 WEA-1004-0 電源装置用     


FOR POWER UNIT
39 1
COPPER STRAP
CODE NO. 500-310-040

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1290-M04-H
A-10
A-11

CODE NO. 006-959-830 10CE-X-9401 -1


TYPE CP10-03610 1/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(8016) 00-8016-038-313761HV 外部インターフェイス用  
FOR DATA INTERFACE
1 1 UNIT
CONNECTOR(8016)
CODE NO. 000-127-234

貼りマーク.J201. 10-018-5022 外部インターフェイス用  


FOR DATA INTERFACE
2 1 UNIT
STICKER.J201.
CODE NO. 181-850-220

コネクタ(54) 54-038-000-601/SC 外部インターフェイス用  


FOR DATA INTERFACE
3 1 UNIT
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 外部インターフェイス用  


FOR DATA INTERFACE
4 38 UNIT
CONTACT PIN (8017)
CODE NO. 000-519-542

コネクタ(RM) RM15TP-2PA 外部インターフェイス用  


FOR DATA INTERFACE
5 1 UNIT
CONNECTOR(RM)
CODE NO. 000-503-314

コネクタ(SRCN) SRCN6A16-10P 外部インターフェイス用  


FOR DATA INTERFACE
6 4 UNIT
CONNECTOR(SRCN)
CODE NO. 000-508-663

コネクタ(SRCN) SRCN6A16-7P 外部インターフェイス用  


FOR DATA INTERFACE
7 1 UNIT
CONNECTOR(SRCN)
CODE NO. 000-508-662

コネクタ(SRCN) SRCN2A16-7P 外部インターフェース工材 


FOR INTERFACE UNIT
8 1
CONNECTOR(SRCN)
CODE NO. 000-508-652

コネクタ(8016) 00-8016-038-313761HV 指示装置用    


FOR DISPLAY UNIT
9 1
CONNECTOR(8016)
CODE NO. 000-127-234

M8化粧ビス 10-054-1144-0 指示装置用    


FOR DISPLAY UNIT
10 4
PANEL SCREW
CODE NO. 100-195-970

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1296-M01-B
A-12

CODE NO. 006-959-830 10CE-X-9401 -1


TYPE CP10-03610 2/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
クーラーパテ 200Gイリ シロイロ 指示装置用    
FOR DISPLAY UNIT
11 2
COOLER PUTTY
CODE NO. 000-807-621

イラックスチューブ(A) 4.0X0.3 キイロ *5CM* 指示装置用    


FOR DISPLAY UNIT
12 1
INSULATION TUBE(A)
CODE NO. 000-100-923

コネクタ(NCS) NCS-252-P 指示装置用    


FOR DISPLAY UNIT
13 1
CONNECTOR
CODE NO. 000-506-501

コネクタ(NCS) NCS-253-P 指示装置用    


FOR DISPLAY UNIT
14 1
CONNECTOR(NCS)
CODE NO. 000-506-503

アース板 WEA-1004-0 指示装置用    


FOR DISPLAY UNIT
15 1
COPPER STRAP
CODE NO. 500-310-040

コネクタ(8016) 00-8016-020-313-703V 受信装置用     


FOR RECEIVER UNIT
16 1
CONNECTOR
CODE NO. 000-111-143

P貼りマーク.11. 10-026-0619-0 受信装置用     


FOR RECEIVER UNIT
17 1
P STICKER.11.
CODE NO. 100-014-880

コネクタ(54) 54-038-000-601/SC 受信装置用     


FOR RECEIVER UNIT
18 3
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 受信装置用     


FOR RECEIVER UNIT
19 114
CONTACT PIN (8017)
CODE NO. 000-519-542

ホールプラグ NO.4567 受信装置用     


FOR RECEIVER UNIT
20 4
HOLE PLUG
CODE NO. 000-800-729

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1296-M02-B
A-13

CODE NO. 006-959-830 10CE-X-9401 -1


TYPE CP10-03610 3/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
アース板 WEA-1004-0 受信装置用     
FOR RECEIVER UNIT
21 1
COPPER STRAP
CODE NO. 500-310-040

シールドスリーブ ZSK-06HF 0.055M 受信装置用     


FOR RECEIVER UNIT
22 20
SHIELD SLEEVE
CODE NO. 000-809-085

圧着端子 FV1.25-3.7 アカ 上下装置用 


FOR HULL UNIT
23 15
CRIMP-ON LUG
CODE NO. 000-108-699

圧着端子 FV5.5-4 上下装置用  


FOR HULL UNIT
24 5
CRIMP-ON LUG
CODE NO. 000-538-123

圧着端子 FV1.25-M4 アカ 上下装置用   


FOR HULL UNIT
25 5
CRIMP-ON LUG
CODE NO. 000-536-715

貼りマーク 10-026-5002-0 送振装置用    


FOR TRANSMITTER UNIT
26 1
STICKER
CODE NO. 100-004-870

コネクタ(54) 54-038-000-601/SC 送振装置用    


FOR TRANSMITTER UNIT
27 3
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 送振装置用    


FOR TRANSMITTER UNIT
28 120
CONTACT PIN (8017)
CODE NO. 000-519-542

圧着端子 FV1.25-M4 アカ 送振装置用    


FOR TRANSMITTER UNIT
29 5
CRIMP-ON LUG
CODE NO. 000-536-715

圧着端子 FV5.5-4 送振装置用    


FOR TRANSMITTER UNIT
30 5
CRIMP-ON LUG
CODE NO. 000-538-123

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1296-M03-B
A-14

CODE NO. 006-959-830 10CE-X-9401 -1


TYPE CP10-03610 4/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
ホールプラグ NO.4567 送振装置用    
FOR TRANSMITTER UNIT
31 4
HOLE PLUG
CODE NO. 000-800-729

アース板 WEA-1004-0 送振装置用    


FOR TRANSMITTER UNIT
32 1
COPPER STRAP
CODE NO. 500-310-040

コンタクト ピン(8017) 60-8017-0313-00-339 電源装置用


FOR POWER SUPPLY
33 38 UNIT
CONTACT PIN (8017)
CODE NO. 000-519-542

圧着端子 FV5.5-4 電源装置用 


FOR POWER SUPPLY
34 15 UNIT
CRIMP-ON LUG
CODE NO. 000-538-123

ホールプラグ NO.4567 電源装置用 


FOR POWER SUPPLY
35 4 UNIT
HOLE PLUG
CODE NO. 000-800-729

貼りマーク.1. 10-026-7018-0 電源装置用  


FOR POWER SUPPLY
36 1 UNIT
STICKER.1.
CODE NO. 100-008-630

コネクタ(54) 54-038-000-601/SC 電源装置用  


FOR POWER SUPPLY
37 1 UNIT
CONNECTOR(54)
CODE NO. 000-132-081

圧着端子 FV1.25-M4 アカ 電源装置用  


FOR POWER SUPPLY
38 6 UNIT
CRIMP-ON LUG
CODE NO. 000-536-715

アース板 WEA-1004-0 電源装置用  


FOR POWER SUPPLY
39 1 UNIT
COPPER STRAP
CODE NO. 500-310-040

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C1296-M04-B
A-15

CODE NO. 006-030-670 10CL-X-9401 -0


TYPE CP10-06610 1/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(8016) 00-8016-038-313761HV 外部インターフェイス工材  
FOR INTERFACE UNIT
1 1
CONNECTOR(8016)
CODE NO. 000-127-234

アース線組品 CS-120-C 外部インターフェース工材


FOR INTERFACE UNIT
2 1
GROUNDING WIRE
CODE NO. 006-937-660

貼りマーク.J201. 10-018-5022 外部インターフェース工材 


FOR INTERFACE UNIT
3 1
STICKER.J201.
CODE NO. 181-850-220

コネクタ(54) 54-038-000-601/SC 外部インターフェース工材 


FOR INTERFACE UNIT
4 1
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 外部インターフェース工材 


FOR INTERFACE UNIT
5 38
CONTACT PIN (8017)
CODE NO. 000-519-542

コネクタ(RM) RM15TP-2PA 外部インターフェース工材 


FOR INTERFACE UNIT
6 1
CONNECTOR(RM)
CODE NO. 000-503-314

コネクタ(SRCN) SRCN2A16-7P 外部インターフェース工材 


FOR INTERFACE UNIT
7 1
CONNECTOR(SRCN)
CODE NO. 000-508-652

コネクタ(SRCN) SRCN6A16-10P 外部インターフェース工材 


FOR INTERFACE UNIT
8 4
CONNECTOR(SRCN)
CODE NO. 000-508-663

コネクタ(SRCN) SRCN6A16-7P 外部インターフェース工材 


FOR INTERFACE UNIT
9 1
CONNECTOR(SRCN)
CODE NO. 000-508-662

コネクタ(8016) 00-8016-020-313-703V 受信装置工材   


FOR RECEIVER UNIT
10 1
CONNECTOR
CODE NO. 000-111-143

10CL-X-9401

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-16

CODE NO. 006-030-670 10CL-X-9401 -0


TYPE CP10-06610 2/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
P貼りマーク.11. 10-026-0619-0 受信装置工材   
FOR RECEIVER UNIT
11 1
P STICKER.11.
CODE NO. 100-014-880

コネクタ(54) 54-038-000-601/SC 受信装置工材   


FOR RECEIVER UNIT
12 3
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 受信装置工材   


FOR RECEIVER UNIT
13 114
CONTACT PIN (8017)
CODE NO. 000-519-542

ホールプラグ NO.4567 受信装置工材   


FOR RECEIVER UNIT
14 4
HOLE PLUG
CODE NO. 000-800-729

アース板 WEA-1004-0 受信装置工材   


FOR RECEIVER UNIT
15 1
COPPER STRAP
CODE NO. 500-310-040

シールドスリーブ ZSK-06HF 0.055M 受信装置工材   


FOR RECEIVER UNIT
16 20
SHIELD SLEEVE
CODE NO. 000-809-085

圧着端子 FV1.25-3.7 アカ 上下装置工材   


FOR HULL UNIT
17 15
CRIMP-ON LUG
CODE NO. 000-108-699

圧着端子 FV1.25-M4 アカ 上下装置工材   


FOR HULL UNIT
18 5
CRIMP-ON LUG
CODE NO. 000-536-715

圧着端子 FV5.5-4 上下装置工材   


FOR HULL UNIT
19 5
CRIMP-ON LUG
CODE NO. 000-538-123

貼りマーク 10-026-5002-0 送信装置工材   


FOR TRANSMITTER UNIT
20 1
STICKER
CODE NO. 100-004-870

10CL-X-9401

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-17

CODE NO. 006-030-670 10CL-X-9401 -0


TYPE CP10-06610 3/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
コネクタ(54) 54-038-000-601/SC 送信装置工材   
FOR TRANSMITTER UNIT
21 3
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 送信装置工材   


FOR TRANSMITTER UNIT
22 120
CONTACT PIN (8017)
CODE NO. 000-519-542

圧着端子 FV1.25-M4 アカ 送信装置工材   


FOR TRANSMITTER UNIT
23 5
CRIMP-ON LUG
CODE NO. 000-536-715

圧着端子 FV5.5-4 送信装置工材   


FOR TRANSMITTER UNIT
24 5
CRIMP-ON LUG
CODE NO. 000-538-123

ホールプラグ NO.4567 送信装置工材   


FOR TRANSMITTER UNIT
25 4
HOLE PLUG
CODE NO. 000-800-729

アース板 WEA-1004-0 送信装置工材   


FOR TRANSMITTER UNIT
26 1
COPPER STRAP
CODE NO. 500-310-040

貼りマーク.1. 10-026-7018-0 電源装置工材  


FOR POWER UNIT
27 1
STICKER.1.
CODE NO. 100-008-630

コネクタ(54) 54-038-000-601/SC 電源装置工材  


FOR POWER UNIT
28 1
CONNECTOR(54)
CODE NO. 000-132-081

コンタクト ピン(8017) 60-8017-0313-00-339 電源装置工材  


FOR POWER UNIT
29 38
CONTACT PIN (8017)
CODE NO. 000-519-542

圧着端子 FV1.25-M4 アカ 電源装置工材  


FOR POWER UNIT
30 6
CRIMP-ON LUG
CODE NO. 000-536-715

10CL-X-9401

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-18

CODE NO. 006-030-670 10CL-X-9401 -0


TYPE CP10-06610 4/4

工事材料表
INSTALLATION MATERIALS
番 号 名  称 略  図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
圧着端子 FV5.5-4 電源装置工材  
FOR POWER UNIT
31 15
CRIMP-ON LUG
CODE NO. 000-538-123

ホールプラグ NO.4567 電源装置工材  


FOR POWER UNIT
32 4
HOLE PLUG
CODE NO. 000-800-729

アース板 WEA-1004-0 電源装置工材  


FOR POWER UNIT
33 1
COPPER STRAP
CODE NO. 500-310-040

10CL-X-9401

FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-19
A-20
A-21
A-22
A-23
A-24
A-25
A-26
D-1
D-2
Y. Hatai
D-3
D-4
D-5

Oct.31'03
D-6

Dec. 10, '02


D-7
D-8
D-9
D-10
D-11
D-12
D-13
D-14
D-15
D-16
D-17
D-18
D-19
D-20
S-1
1 2 3 4 5 6

電源装置 TB-E1 TB-B1 54-038-000 00-8016-038

SAME AS THE
10S1259,MAX.20m,φ16.5 -601/SC -313-761HV

他端に同じ

TT OTHER SIDE
POWER UNIT 10 アカ RED 1
1 CN-B2
10S1258,MAX.50m,φ18.6 CN-A1 1 外部インターフェイス
11 クロ BLK 2 送振装置 A アカ RED A 他端に同じ INTERFACE UNIT
CSH-880 12 シロ WHT 3 TRANSMITTER B チャ BRN
P
5 00-8016-038 00-8016-038 CS-120A

CN-E1 2
SAME AS THE
13 チャ BRN 5 UNIT C クロ BLK TT OTHER SIDE CN-A5 -313-761HV -313-761HV J201
TB-E1

14
P
6 CSH-810 D
P 10S1258,MAX.20m
クロ BLK シロ WHT *3 A A 他端に同じ
CN-A1に同じ
E ダイ ORG (*6) SAME AS THE

A
1
2
3
4
5
6
7
8
9
*3 *3 SAME AS
A F チャ BRN
P
CN-A1 TT TT OTHER SIDE

54-038-000
-601-SC
54-038-000 54-038-000 H アカ RED
10S1259,MAX.20m

*3

*3
-601/SC -601/SC LL
P CS-120C
WEA1004 1 CN-C3 10S1258,MAX.20m,φ18.6 CN-B3 1 ダイ ORG 5m
P 00-8016-038 00-8016-038

*3
受信装置 A アカ RED A 他端に同じ J クロ BLK

10S1260,MAX.20m
W=50,1.2m P P -313-761HV -313-761HV
RECEIVER UNIT B チャ BRN SAME AS THE K ハイ GRY *5 3 CN-A3 10S1258,MAX.30m CN-A1/A2/A3
アカ RED
クロ BLK
シロ WHT
チャ BRN
クロ BLK

TT OTHER SIDE
*1
DPYCY-4

C クロ BLK L キ YEL 他端に同じ A アカ RED A


CSH-220A/ D
P
シロ WHT M チャ BRN
P
SAME AS THE チャ BRN
P
B 副指示器
*3
54-038-000 220K/220FⅡ E ダイ ORG N クロ BLK OTHER SIDE RR クロ BLK C SUB DISPLAY
P P P
-601/SC CN-C1 2 F チャ BRN P ムラサキ PPL *3 シロ WHT D CSH-216 *2
100/110/220VAC

A H アカ RED R ダイ ORG ダイ ORG E CSH-236


指示装置
1
2
3
4
5

CN-C4に同じ
TB-D2

P P P
1φ,50/60Hz

SAME AS LL ダイ ORG S クロ BLK チャ BRN F


TT CN-C4 J クロ BLK 54-038-000 T クロ BLK
DISPLAY UNIT アカ RED H
上下制御箱 *3 K
P
ハイ GRY -601/SC CN-B4 3 U アカ RED
P
CSH-210 ダイ ORG
P
LL
RAISE/LOWER
00-8016-020
L
P
キ YEL シロ WHT
P
A V キ YEL
P
CSH-2200 クロ BLK
P
J
CONTROL BOX
-313-703V M チャ BRN アカ RED E X クロ BLK CSH-830 ハイ GRY K
TB-D1 10S1261,φ20 CN-C2 1 N クロ BLK シロ WHT B W チャ BRN キ YEL L
P P P P
7 チャ BRN A P ムラサキ PPL アオ BLU F Y クロ BLK チャ BRN M
P
8 クロ BLK B R ダイ ORG ムラサキ PPL C Z ミドリ GRN クロ BLK N
P P P P
2 クロ BLK C S クロ BLK ミドリ GRN J AA クロ BLK ムラサキ PPL P
P
1 アカ RED D T クロ BLK ムラサキ PPL D BB ダイ ORG R
B ダイ ORG
P
E U
P
アカ RED アカ RED
P
K CC ドウジク COAX. クロ BLK
P
S
クロ BLK F V キ YEL ミドリ GRN L DD ミドリ GRN H10P-SHF-AA CN-A13 クロ BLK T
H
P P
EE
P リモート箱 P
U
4 クロ BLK X クロ BLK シロ WHT R チャ BRN 1 アカ RED
P
FF REMOTE BOX V
3 キ YEL J W チャ BRN キ YEL N クロ BLK キ YEL

10S1627,7m
P P P CSH-116 P
ミドリ GRN K Y クロ BLK クロ BLK T HH アオ BLU クロ BLK X
P
クロ BLK M Z ミドリ GRN アオ BLU P JJ アオ BLU チャ BRN W
P P P P
5 アオ BLU L AA クロ BLK ムラサキ PPL U KK チャ BRN 10 クロ BLK Y
P
6 クロ BLK R BB クロ BLK V MM チャ BRN ミドリ GRN Z
P P P
*3 X CC ドウジク COAX. アオ BLU X NN シロ WHT 10S1258,MAX.30m CN-A4 4 *5 クロ BLK AA
*3 DD ミドリ GRN シロ WHT W PP ムラサキ PPL クロ BLK C BB
P P P
EE チャ BRN キ YEL Y RR チャ BRN シロ WHT D ドウジク COAX. CC
FF クロ BLK ミドリ GRN BB SS チャ BRN クロ BLK J ミドリ GRN DD
P P P P
HH アオ BLU クロ BLK FF TT ハイ GRY ハイ GRY K チャ BRN EE
JJ アオ BLU キ YEL CC キ YEL L アオ BLU JJ
P P *3 P
C101 KK チャ BRN ムラサキ PPL HH リモートディスプレイ チャ BRN M チャ BRN KK
#1 P1~P5 MM チャ BRN クロ BLK DD REMOTE DISPLAY キ YEL V ムラサキ PPL PP
P P P
*3 C102 NN シロ WHT アカ RED JJ CSH-106 *2 クロ BLK X チャ BRN RR
#2 P1~P5 PP ムラサキ PPL キ YEL KK CN-A1/A2/A3 チャ BRN W *3
送受波器 RR
P P
PP Y CN-A7
チャ BRN ハイ GRY 他端に同じ C クロ BLK R
CN-A8 ECX-3C2V-T,MAX.30m,
R (CN-A4/A7/A10)
TRANSDUCER SS チャ BRN アオ BLU LL SAME AS THE BB G G (CN-A5/A8/A11)
C C116 TT
P
ハイ GRY ハイ GRY
P
RR OTHER SIDE CC ドウジク COAX. CC B
CN-A9 (14S4382),φ13.7
B (CN-A6/A9/A12)
#16 P1~P5 *3 アカ RED MM NCS-253P H10P-SHF-AA CN-A13
P CN-A10 リモート箱
54-038-000 ハイ GRY SS 3 (CN-A4/A7/A10) R R 1
ECX-3C2V-T,MAX.30m, CN-A11 REMOTE BOX
3 CN-C4 -601/SC ミドリ GRN NN 2 (CN-A5/A8/A11) G G

10S1627,7m
10S1260,MAX.20m P φ13.7 CN-A12 CSH-116
他端に同じ A ハイ GRY TT 1 (CN-A6/A9/A12) B B
SAME AS THE *3
OTHER SIDE TT 10
上下装置 *3
WEA1004 *1 NCS-253P CN-A15
W=50,1.2m DPYCY-1.5
HULL UNIT 100VAC 3
DPYCY-1.5
*1 NCS-253P CN-A15
WEA1004 1φ,50/60Hz 2 100VAC 3
CSH-81080/81120 W=50,1.2m *1 *1 変圧器 1 1φ,50/60Hz 2
100VAC DPYCY-1.5 110/220VAC DPYC-1.5 TRANSFORMER 1
1φ,50/60Hz 1φ,50/60Hz PT-400 *2 WEA1004
W=50,1.2m WEA1004
W=50,1.2m

注記 NOTE
*1)造船所手配。 *1: SHIPYARD SUPPLY.
*2)オプション。 *2: OPTION. DRAWN TITLE

*3: GROUND THRU CABLE CLAMP.


Jul. 12 '06 T.YAMASAKI CSH-81/82/83
*3)ケーブルクランプで接地。 CHECKED 名称
*4)□内の数値は誤挿入防止ピンA(太)位置を示す。 *4: NUMERAL IN □ SHOWS POSITION OF CONNECTOR GUIDE PIN[B]. Jul. 12 '06 T.TAKENO カラースキャニングソナー
ガイドピンB(細)は全て“1”に設定。 GUIDE PIN[S] IS SET ALWAYS TO POSITION “1”. APPROVED

*5: DO NOT CONNECT RGB LINE (CONNECTOR FF/HH, MM/NN, SS/TT) OF Aug. 22 '06 T.Matsuguchi 相互結線図
*5)10S1258のRGBライン(FF/HH,MM/NN,SS/TT)は接続しないこと。 SCALE MASS NAME
画面の映像が歪む原因となることがあります。 CABLE 10S1258. OR INTERFERENCE MAY APPEARS ON THE DISPLAY. kg COLOR SCANNING SONAR
*6)88kHzセットでは、アジロがい装を指示装置に接地しないこと。 *6: DO NOT CONNECT CABLE ARMOR TO DISPLAY UNIT FOR 88kHz SET. DWG.No.
C1290-C01- K INTERCONNECTION DIAGRAM
1 2 3 4 5 6 S-2

送振装置 操作制御部
TRANSMITTER UNIT PROCESSOR UNIT RGB 10P6949 *3
CSH-23/23K/23F/53/58/83 3COX-2P-6C 5/10mまたは同等品 *2
CSH-235/235F/235K/ CN-A16 D-sub or equivalent D-sub
*7
送受信装置 *4 835/585/535/735 R 1 1
TRANSCEIVER UNIT G 古野製モニター MU-151C
A CSH-73 CN-B2 1 54-038-525-601/SC
B 択一
FURUNO MONITOR
A RED アカ P Selection
H 15 15 または OR
B BRN チャ CN-A15
*1 NCS-253P V 1
C BLK クロ
P DPYCY-1.5
1 GND D-sub 市販モニター(CRT/LCD)
D WHT シロ 100VAC 2 AC Commercially available monitor
1φ,50-60Hz 75Ω同軸ケーブル *2
E ORG ダイ 3 AC CN-A17 BNC
P Coaxial cable, MAX. 30m
F BRN チャ *7 R 15
H RED アカ トランス G
LL ORG ダイ
P TRANSFORMER B
J BLK クロ PT-400 H
P
K GRY ハイ V
110/220VAC
L YEL キ
P 1φ50-60Hz
M BRN チャ CONE 10P6711 J21 D-sub
N BLK クロ *4 *3
P 9pin 00-8016-038-313-761HV
P PPL ムラ CN-A5 5
R ORG ダイ A RED アカ P
P
S BLK クロ 00-8016-038 B BRN チャ
*4 -313-761HV *4
T BLK クロ C BLK クロ
P 1 CN-A1 P J201 1 外部インターフェイス
U RED アカ D WHT シロ 10S1258 or
10S1258 or *3
V YEL キ S10-10-20(38P),φ18.6 SAME AS E ORG ダイ S10-17-20(38P),φ18.6 SAME AS INTERFACE UNIT
P P CN-A5
B X BLK クロ 20m MAX.: CSH-58
50m MAX.: CSH-23/23F/23K/73/83
CN-B2 F
H
BRN チャ 20m MAX. CS-120A
W BRN チャ RED アカ
P 80m MAX.: CSH-53 P
Y BLK クロ LL ORG ダイ
Z GRN ミド J BLK クロ
P P
AA BLK クロ K GRY ハイ
BB SHIELD シールド L YEL キ 副指示器 *2
P
CC CO-AX 同軸芯線 M BRN チャ SUB DISPLAY UNIT
DD GRN ミド N BLK クロ CSH-236/236F/536/586
P P
EE BRN チャ P PPL ムラ
*3 00-8016-038-313-761HV CN-A1/A2/A3
FF BLK クロ R ORG ダイ
P H10P-SHF-AA 1 CN-A13 P RED アカ A *5
HH BLU アオ S BLK クロ P
リモート箱 10S1627 T BLK クロ
BRN チャ B
JJ BLU アオ BLK クロ C
KK BRN チャ
P REMOTE 7m U RED アカ
P
P
CONTROL BOX 10 WHT シロ D
MM BRN チャ V YEL キ
P ORG ダイ E
NN WHT シロ
P CSH-135/116 X BLK クロ P
BRN チャ F
PP PPL ムラ W BRN チャ
P P RED アカ H
RR BRN チャ Y BLK クロ P
ORG ダイ LL
SS BRN チャ Z GRN ミド
P P BLK クロ J
TT GRY ハイ AA BLK クロ P
GRY ハイ K
BB SHIELD シールド
*6 YEL キ L
C CC
DD
CO-AX 同軸芯線 P
BRN チャ M
GRN ミド
P BLK クロ N
EE BRN チャ P
PPL ムラ P
FF BLK クロ
P ORG ダイ R
HH BLU アオ P
BLK クロ S
JJ BLU アオ
P BLK クロ T
KK BRN チャ P
RED アカ U
MM BRN チャ
P YEL キ V
NN WHT シロ P
BLK クロ X
PP PPL ムラ
P BRN チャ W
RR BRN チャ P
BLK クロ Y
SS BRN チャ
P GRN ミド Z
TT GRY ハイ P
BLK クロ AA
注記 *6 SHIELD シールド BB
*1. 造船所手配。 CO-AX 同軸芯線 CC
*4 DD
*2. オプション。 P
GRN ミド
CN-A3 3 BRN チャ EE
*3. 圧着端子、コネクタは取付済み。 *2
SAME AS 10S1258,φ18.6 BLU アオ JJ
*4. □内の数値は誤挿入防止ガイドピンA(太)の位置を示す。 CSH-236/236F/536/536F
P
30m MAX. BRN チャ KK
ガイドピンB(細)はすべて”1”に設定。 *5 PPL ムラ PP
D *5. 10S1258のRGBライン(FF/HH,MM/NN,SS/TT)は接続しないこと。 P
BRN チャ RR
画像の映像が歪む原因となることがあり。
*1
*6. ケーブルクランプで接地。 *2
(CN-A7) R R (CN-A4/7/10)
*7. 同軸ケーブルを使用するときは内部でBNCコネクタを付けかえる。 (CN-A8) G
ECX3C-2V-T,φ13.7
G (CN-A5/8/11)
(14S4382)30m MAX.
(CN-A9) B B (CN-A6/9/12)
NOTES
*1. SHIPYARD SUPPLY.
*2. OPTION. DRAWN TITLE
*3. CONNECTOR/LAG FITTED AT FACTORY. Feb.15,'05 E. MIYOSHI CSH-235/235F/235K/835/585/535/735
*4. □ SHOWS POSITION OF CONNECTOR GUIDE PIN(LARGE). CHECKED NAME
GUIDE PIN(SMALL) IS SET ALWAYS TO POSITION '1'. TAKAHASHI. T カラースキャニングソナー操作制御部
*5. DO NOT CONNECT RGB LINE (FF/HH,MM/NN,SS/TT) ON 10S1258, OR *1 APPROVED
IV-8.0SQ. Y. Hatai 相互結線図
INTERFERENCE MAY OCCUR ON DISPLAY. PE 保護アース
SCALE MASS REMARK
*6. GROUNDED THRU CABLE CLAMP. kg COLOR SCANNING SONAR PROCESSOR UNIT
*7. WHEN COAXIAL CABLES ARE USED, REPLACE THE BNC CONNECTORS. DWG No.
C1304-C01- B INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1 2 3 4

インターフェイス
INTERFACE UNIT CIF
CS-120A J204 SRCN6A16-10P
DISP TD-H 1
(00-8016-038
J201 -313-761HV) TD-C 2
指示装置 10S1258,MAX.20m TTYCS-1 *1 航法機器
A RD-H 3
P NAV. EQUIPMENT
DISPLAY UNIT RD-C 4
A Z DTR-H 5
AA DTR-C 6
DSR-H 7
TT DSR-C 8
ゾンデ接続箱 NC 9
FNZ JOINT BOX SRCN6A SRCN6A FNZ GND 10
ネットゾンデ TB1 CS-170 J701 16-10P *2 16-10P J202 GYRO
NET SONDE VCTS-2x0.75 CO-0.2x5P SRCN6A16-10P
1 5 SONDE1-H 1 1 SONDE1-H J205
#1 P CO-0.2x5P *2 ADコンバータ
2 #2 6 SONDE1-C 2 2 SONDE1-C DATA-H 1
P AD CONVERTER
3 #3 7 SONDE2-H 3 3 SONDE2-H DATA-C 2
P AD-100
TB2 SONDE2-C 4 4 SONDE2-C CLK-H 3
P
3 SONDE3-H 5 5 SONDE3-H CLK-C 4
P
4 SONDE3-C 6 6 SONDE3-C GND 10
5 KP-H 7 7 KP-H CI/NMEA
P
6 KP-C 8 8 KP-C J207 SRCN6A16-10P
WL-H 9 WL-H CO-0.2x5P *2 潮流計
7 9 TD-H 1
P P CURRENT INDICATOR
8 WL-C 10 10 WL-C TD-C 2
インターフェイス RD-H 3
P
INTERFACE SRCN6A SRCN6A E/S RD-C 4
VI-1100A *3 DTR-H
02S8040,MAX.100m,φ9 16-7P J705 TB1 02S8040,MAX.100m,φ9 16-7P J203 5
P
B 1 シロ WHT 1 ES_SIG-H ES_SIG-H 1 シロ WHT 1 ES_SIG-H DTR-C 6
P P
2 アオ BLU 2 ES_SIG-C ES_SIG-C 2 アオ BLU 2 ES_SIG-C DSR-H 7
P
3 キ YEL 3 KP WL 3 キ YEL 3 KP DSR-C 8
4 ミドリ GRN 4 SONDE NC 4 4 NC NC 9
P
5 モモ PNK 5 WL TB2 モモ PNK 5 WL GND 10
6 ダイ ORG 6 SHIELD KP 3 ダイ ORG 6 SHIELD LOG
7 クロ BLK 7 GND GND 6 クロ BLK 7 GND J206 RM15TP-2PA
アカ RED アカ RED DPYC-1.5 *1 スピードログ
DATA-H 1
DATA-C 2
SPEED LOG
GND *1
IV-8sq. NMEA
J208 SRCN6A16-7P
インターフェイス TD-H 1
INTERFACE TD-C 2
VI-1100A RD-H 3 TTYCS-1 *1 GPS航法装置
魚群探知機 P GPS NAVIGATOR
1 シロ WHT RD-C 4
E/S P
2 アオ BLU NC 5
3 キ YEL SHIELD 6
4 ミドリ GRN GND 7
5 モモ PNK
注記 6 ダイ ORG
CS-120C,5m
C 7 クロ BLK
*1)造船所手配。 アカ RED
*2)オプション。
*3)魚探が一台のときのみ接続。 DRAWN TITLE
ネットゾンデ不使用時 Jun. 19 '06 T.YAMASAKI CS-120A
WHEN NET SONDE IS NOT USED. CHECKED 名 称
NOTE Jul. 4 '06 T.TAKENO インターフェイス
*1. SHIPYARD SUPPLY. APPROVED
Jul.24 '06 T.Matsuguchi 相互結線図
S-3

*2. OPTION. SCALE MASS NAME


INTERFACE UNIT
*3. USE ONLY FOR ONE E/S UNIT CONNECTION. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG.No.
C1238-003- M INTERCONNECTION DIAGRAM