Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
References
MNL029 05/01
Page 3 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
1.0 INTRODUCTION
Batch reactors are used extensively for the manufacture of small volume high value added
products increasingly in production facilities intended for multipurpose use.
Operators are also required to notify the appropriate Environment Agency of the peak and
total emissions to the environment from their processes.
Batch processes are inherently transient in nature and the process engineer is being called
upon to demonstrate dynamically the adequacy of the equipment design in this increasingly
regulatory environment.
This paper reviews the basic techniques for process modelling and control of batch reaction
systems under steady state and dynamic conditions.
A further important consideration in the design and safe operation of batch reaction systems
is the design of the emergency pressure relief and blowdown facilities which is beyond the
scope of this paper. However, this topic is covered extensively elsewhere.(2) (5)
Several process modelling packages are available for the study of steady state conditions and
the behaviour of batch processes. This paper is based on the Chemstations range of
integrated packages which are linked to a considerable component physical property
database complete with extensive thermodynamic options to allow a detailed study and
understanding of all aspects of batch processing.
MNL029 05/01
Page 4 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
The heat removal requirement depends on the type of reaction. Vapour pressure systems
with reaction at the reflux temperature are referred to as a tempered reaction system due to
heat removal by latent heat reducing the heat removal requirement for the jacket/coil cooling
system.
Gassy systems generate a permanent gas and require total heat evolved to be absorbed by the
jacket/coil cooling system.
Hybrid systems are a combination of the previous two reaction types and can result in a
significant emission of volatile organic compounds (VOC) from the overhead condensing
system due to inerts.
The reaction rate (1) depends on the reaction order where a first order reaction conversion
varies with time and a second order reaction conversion varies with square of the reactant
concentrations. First order reactions have the highest rate where the conversion is least
i.e. at time zero.
The reaction rate can be limited by adding the reactant continuously at a controlled rate to
ensure heat of reaction rate does not exceed the heat removal capability of the system.
Some reactions are carried out with all the reactants charged i.e. “all on board”. Their
reactions are frequently carried out at total reflux which enhances the system heat removal
capability.
Predicting the physical properties of the reaction mix during various steps in the process due
to composition and temperature changes can have a significant effect on the reactor
performance. ChemCAD includes an extensive component database with facilities for User
added components which in conjunction with CCReacs provides a powerful modelling tool
for predicting homogeneous reaction mixtures essential for thermal and emergency relief
design.
MNL029 05/01
Page 5 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
2.2.1 Thermal
An inherent characteristic of stirred batch reactors with coils or external jackets is the
thermal lags associated with the heat capacities of the reactor, reaction mix, jacket contents
and jacket service system and the dead time of the circulation system. Typically glass lined
reactors vary in weight from 475 kg (100L) to 12200 kg (12500L) with equivalent jacket
volumes of 46L and 1200L. The lags associated with the jacket services using thermal fluids
are minimised by using forced circulation and plate heat exchangers for fast response. A
reactor thermal rating spreadsheet is available as a design aid to establish overall plant utility
requirements (6) for typical systems (refer Figure 8).
The thermal conductivity of the reactor material of construction has a significant effect on
wall temperatures, as demonstrated in Section 4, which can limit cycle times. Extreme
temperature differences can result in product quality problems on certain processes.
Refer to Appendix I for a review of the heat transfer theory which is further covered in the
literature.(7) However, for poorly designed jacket services the jacket side film coefficient
will become controlling if turbulent conditions are not established. The use of forced
circulation and jacket inlet mixing nozzles on thermal fluid systems is essential.
The heat removal capability of the service system is a function of the resistances to heat
transfer, the temperature difference between reaction temperature and jacket/coil side
temperature and heat transfer area. A thermal runaway (increasing reaction temperature
increases rate of reaction) will occur if the heat cannot be removed fast enough, e.g.
reduction in heat transfer area due to reduction in reactor contents.
It may not always be possible to design for stability where enough heat transfer area is
provided for the design temperature difference. However, stability will be assured if heat is
removed by boiling one or more of the components since this tends to make the system
isothermal.
The natural period of batch reactors can vary between 15 and 60 minutes (Refer Appendix
III) and will increase on approach to instability making control more difficult.
There is extensive literature available on agitation systems with some manufacturer’s having
proprietary arrangements. The Seider Tate correlation (Appendix I) is used to predict reactor
inside film coefficients based on agitation system constants determined empirically.
MNL029 05/01
Page 6 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
2.2.2 Overheads
The presence of non condensables in the condenser results in a significant increase in the
thermal resistance which can result in up to half the heat transfer area being required for the
last zone alone.
ChemCAD Therm uses a method based on Silver (8) and Bell & Khaly (9) to account for non
condensables with wet film and dry film condensing options.
Adopting holistic methods for condenser sizing, e.g. condenser area equal to reactor heat
transfer area, can result in significant undersizing when applied to multipurpose plant
operations.
MNL029 05/01
Page 7 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
These systems involve the connection of the appropriate supply and return services directly
to the reactor jacket/coils. Systems are in use providing operating ranges from –20°C to
180°C with ethylene/glycol mixes, water and steam as services. Ethylene glycol mixes
should not be used above their boiling point.
There are many arrangements in use from total manual control to full automatic control
involving forced circulation with steam/water mixing facilities. Ciba Geigy and Wiegand
developed a steam jet heater providing a wide range of heating duties with a single phase in
the operating range 5°C to 180°C. This arrangement requires careful design in relation to air
removal/expansion/pressurisation facilities and service returns from high operating
temperatures require special automatic blowdown facilities.
These systems provide excellent thermal response due to the elimination of heat transfer lags
associated with heat exchangers. However, to provide combined heating/cooling facilities,
with the exception of the Wiegand system, requires involved automatic valve sequencing
and jacket/coil blowdown routines when changing services resulting in discontinuous
control which can cause serious operational problems when handling exothermic reactions.
Operational problems associated with these systems include cross contamination of services,
corrosion and the need for complex control routines when changing services from heat to
cool involving time lags. These systems are not always cheaper than other alternatives.
It is now considered standard practice to use single fluid systems based on heat transfer
fluids with external heat exchangers.
MNL029 05/01
Page 8 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
This system is based on the use of a single appropriate heat transfer fluid for the desired
operating range, typically –20°C to 180°C.
The coolant is directly injected into the reactor jacket/coil circulating loop and a heat
exchanger with steam is provided for heating. Changeover between heating and cooling
modes is seamless using control valves in split range.
Thermal response on cool is excellent due to direct injection and the use of a three way
valve on the heat exchanger minimises thermal lags on heating.
Adopting a three way valve allows the steam to be applied continuously to the heat
exchanger shell at full pressure which eliminates problems associated with condensate
lift/return, prevents freezing when operating below 0°C and provides excellent linear control
characteristics.
Equipment in common use include sealless pumps and gasket free fully welded plate and
shell heat exchangers.
The key design parameters to be determined are circulation rate and heat exchanger sizing.
The circulation rate is set depending on the number of mixing nozzles to be supplied and
achieving the recommended nozzle pressure drop. The heat transfer fluid is on the plate side
of the shell and plate heat exchanger, which provides a high film coefficient.
The heat transfer area is selected based on a reasonable LMTD at approach to service supply
temperature and is sized to ensure that reactor heat transfer is limiting.
ChemCAD modelling of the system establishes the thermal response of the system selected.
The key features of this system are as for the previous Scheme 2. However, the use of an
additional heat exchanger for cooling allows the selection of a less expensive fluid for the
cooling service which may provide cost benefits with a centralised refrigeration facility
involving the use of significant volumes of heat transfer fluid.
This system also allows for segregation of the reactor service system from other reactors
which enables rapid identification of water breakthrough problems on a facility with several
reactors.
MNL029 05/01
Page 9 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
The conventional control system uses cascade control with reactor contents temperature
(master/primary) being cascaded to jacket/coil inlet/outlet temperature (slave/secondary).
This system provides the following benefits:-
1. Disturbances in the jacket/coil loop are corrected by the secondary controller before they
can influence the primary controller. However, the secondary loop thermal time constant
must be less than the primary loop thermal time constant, which is in fact the case (refer
Appendix III).
3. Secondary loop gain variations are overcome within its own loop.
The secondary controller is ideally a Proportional only controller as Integral Action Time
will slow the respons e. A proportional band of < 25% is typical. However, when carrying
out boil up control it is desired to set a temperature difference between jacket/coil and
reactor contents by controlling jacket/coil inlet temperature. In this mode Integral Action is
required to eliminate offset.
The primary controller is Proportional + Integral + Derivative and presents special problems
for initial loop tuning and operation. Refer to Appendix III for a detailed discussion.
Control valve actuators are pneumatic with positioners fitted. The calibration for split range
operation of the valves should be achieved at the positioners, not with scaled multiple
controller outputs, to ensure loop integrity is maintained. Control valve characteristic used is
normally equal % though situations may arise where a linear characteristic provides better
control. Refer to Appendix II for further discussions.
ChemCAD provides the facilities to carry out extensive modelling of the control loop
responses for all operational modes and establishes the system stability characteristics.
MNL029 05/01
Page 10 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Reactor performance predictions are shown in the Attachments. The model used is
essentially Scheme 3 (Figures 2, 3) with external heat exchangers.
The reactor studied was a 1600L Hastelloy C Reactor with a single jacket and reactor
contents were based on 1000 kg toluene.
The heat transfer fluid selected was Dowtherm J with flowrates as indicated in Figure 3.
The external heat exchangers UA are as indicated in Figures 2 and 3 and are based on
Vahterus plate and shell type units.
Graphs 4 and 5 demonstrate the use of the Ziegler Nichols tuning method for the Condenser
Model (Figures 4 and 5) as discussed in Appendix III.
The possibilities available are extensive and depend very much on the initiative of the user
and the particular problem being studied.
MNL029 05/01
Page 11 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Appendix I
For a three bladed impellor agitator the inside film coefficient hi is predicted by
0 . 14
µ bulk
Nu = 0.33 * (Re ) 0 . 67
(Pr ) 0 . 33
µ
wall
D
Where Nu = Nusselt Number = hi
k
Inside film coefficient hi Btu/ft 2 h°F
Inside reactor diameter D ft
Thermal conductivity of process fluid k Btu/ft 2 h°F/ft
ρn d 2
Re = Reynolds Number =
µ
Impellor rotation rate (normal 90 rpm) n rpm
Impellor diameter d ft
Process fluid density ρ consistent units
Process fluid viscosity µ consistent units
C pµ
Pr = Prandtl Number =
k
Process fluid specific heat Cp consistent units
µ bulk
Normally the viscosity ratio term is unity and can therefore be ignored.
µ wall
Glass wall
kg
For heat transfer through glass linings use
Lg
Where kg = thermal conductivity of glass = 6.9 Btu/ft2 h°F/in
Lg = glass thickness (in)
Glass thickness can very between 1 mm and 2 mm. Use 1.5mm(0.06in) thick as a good average.
MNL029 05/01
Page 12 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Metal wall
Overall conductivity (k o) for a glass lined vessel is given by (CCReacs allows only one value)
L m+ L g
ko =
Lg k g + Lm k m
For steam on the jacket side take an outside film coefficient of 8517 w/m2 K (1500 Btu/ft2 h°F)
For water or other fluid on the jacket side, use the Pfaudler equations or consult the circulating
nozzle leaflets.
Fouling coefficients
Fouling on inner vessel - allow 5678 w/m2 K (1000 Btu/ ft2 h°F) ffi
2 2
Fouling on jacket side - allow 5678 w/m K (1000 Btu/ ft h°F) ffo
or substitute known values.
1 1 1 1 1 1 1
=+ + + + + +
U hi ff i k g L g k m Lm ho ff o
MNL029 05/01
Page 13 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Nu = C Re0.667 Pr p (ç p / ç w)q
D nd 2 Cpì
Nu = hi Re = Pr =
k ì k
C,p,q = constants for Agitator
Nu = Nusselt number
Re = Reynolds number
Pr = Prandtl number
D = Vessel internal diameter
d = Agitator diameter
n = RPM of agitator
ηp = process side dynamic viscosity
ηw = process side wall viscosity
k = process side thermal conductivity
hi = heat transfer coefficient, product side
Cp = process fluid specific heat
Agitator Constants
MNL029 05/01
Page 14 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Toluene 59 55 55 55 56 232
Chloroform 60 57 57 57 57 259
Acetone 62 59 59 58 58 284
1 1 1 1 1 1 1
=+ + + + + +
U hi 1000 k g L g k m L m ho 3333
ffi ffo
1 1 1 1 1
= + = + (symbols as above)
k o Lo k g L g k m Lm 117 600
Let US = overall heat transfer coefficient for steam ho =1500 for steam
UO = overall heat transfer coefficient for oil ho = 250 for oil
1 1 1 1
= − +
U o Us 1500 250
MNL029 05/01
Page 15 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Appendix II
The selection of a control valve with the appropriate operating characteristics is essential for
satisfactory control loop performance. A valve has two characteristics namely the inherent
characteristic (relationship between flow and stroke at constant ∆P) and the operational
characteristic where the inherent characteristic is modified by the process pressure conditions.
An equal % valve operating characteristic tends towards a linear characteristic as ∆P max/∆P min
increases. A linear valve operating characteristic tends towards a quick opening characteristic as
∆P max/∆P min increases.
The operational characteristic of a valve can also be modified by controller output signal
characterisation using various techniques.
The graph of valve stem position vs flow demonstrates the range of valve characteristics available
(refer Figure 6).
∆P max will be close to maximum shutoff ∆P and ∆P min at full flow should not be underestimated
which favours equal % characteristic.
ChemCAD allows dynamic analysis of the process enabling appropriate characteristic selection.
MNL029 05/01
Page 16 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Appendix III
When tuning control loops it is important to understand the impact the tuning parameters have on
the process.
1. Proportional Band
Wide PB (50 – 500%) on fast and noisy processes such as Flow, Liquid Pressure and
Composition.
Narrow PB (1- 50%) on slow processes such as Gas Pressure, Temperature and Vapour
Pressure.
Integral action time changes the controller output at a rate proportional to the magnitude of
the error (e) and should never be set so short such that the resulting load change imposed
exceeds the load response characteristics of the process. (Consider approaching a corner too
fast).
Short Ti (0.05 – 2 min) on fast and noisy processes such as Flow and Liquid Pressure.
Long Ti (2 – 120 min) on slow processes such as Temperature, Vapour Pressure and
Composition.
Ti is unnecessary on Gas Pressure and is seldom used on Liquid Level as steady flow is
usually the required condition.
Derivation Action Time changes the controller output at a rate proportional to the rate of
change of error and as such should never be used on noisy processes such as Flow,
de
dt
Liquid Pressure and Liquid Level.
MNL029 05/01
Page 17 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
When a sustained error is maintained between set point and measured variable on a controller
with Ti the output is driven off scale (valve full open or closed).
Control action does not commence until the measured variable crosses the set point resulting
in overshoot.
Ziegler and Nichols (4) developed the Ultimate Sensitivity Method which provides a useful
basis for control loop tuning as follows:-
2. Reduce PB whilst making small set point changes (both directions) until the measured
variable begins to oscillate at constant amplitude.
The proportional band PBu and the period Tu are noted.
P only controller
PB = 2 PBu %
P + I controller
PB = 2.2 PB u %
T
Ti = u mins
1.2
P + I + D controller
PB = 1.6 PBu %
T
Ti = u mins
2
T T
Td = u = i
8 4
This procedure can be used as a ‘starting point’ for tuning control systems on batch processes,
Tu being established at a stable condition. Typical periods (T u) for batch reactors vary in the
range 15 to 60 minutes.
Fine tuning involves a trade off between the conflicting requirements of heat up/cool down to
a set point, control of exothermic reactions at a set point, controlling on jacket temperature to
achieve required boil up rates and constraints associated with wall temperature requirements.
MNL029 05/01
Page 18 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Q = h1 A (T )
− T 1 + W 1C1
dT
dt
Batch Reactor Model Parameters
Γ1 =
W 1C1 = W 1C1
h1 A Q T
( − T1 ) 15.4 min
1000 x 0.478
387.2 x 4.82
= 0.25h
(For 12500L reactor with 25.2m2 area the thermal time constant becomes 37 min full toluene
charge).
The thermal time constant for reactor outside wall to reactor inside wall is given by
The thermal time constant for reactor outside wall to jacket contents is given by
W 3C 3 = W 3C 3 ( − ) 453 x 0.55
Γ3 = 2.6 min = 0.043h
h3 A Q T 2 Tc 1205 x 4.82
MNL029 05/01
Page 19 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
The reactor contents time constant based on the overall heat transfer coefficient U as defined in
Appendix I is given by:-
W 1C1
Γo = 21.7 min
U A
By studying the heat up and cool down curves from CCReacs dynamic simulations the thermal
response can be characterised where we have:-
1 63.2
2 87.0
3 95.0
4 98.0
MNL029 05/01
Page 20 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Appendix IV
The following provides a summary of key points to achieve rapid results from the dynamic models.
PID Controller
The controller algorithm is respresentative of a model which does not exhibit interaction between
control modes:-
100 1 de
Controller output Pout = e + ∫ edt + Td +P
PB Ti dt o
Direct action (increasing input / increasing output or decreasing input / decreasing output)
e = Cin – Cset (level with fail closed valve)
Reverse action (increasing input / decreasing output or decreasing input / increasing output)
e = Cset – Cin (heating with fail closed valve / cooling with fail open
valve)
The controller output can be directed to one valve or two valves for split range operation or another
controller set point for cascade operation, assign UnitOp identifiers as appropriate.
The measurement can be derived from a stream or equipment variable. For reaction temperature
locate controller in jacket inlet stream and assign Calculated Temperature.
For batch processes set the steady state controller output (Po ) at the simulation start value i.e. full
open or full closed control valves.
MNL029 05/01
Page 21 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
It is beyond the scope of this note to cover all aspects of this module, refer to ChemCAD CCReacs
for a detailed description. However, the following should be taken into consideration:-
If a value for valve flow coefficient Cv is not known use the Equipment Sizing Cv option which will
provide a value at stated stream conditions.
Control valve rangeability based on the ratio of maximum to minimum controllable flows depends
on the entire control loop. For simulation use 50 for equal % characteristic and 10 for linear
characteristic.
The control valve action in relation to the controller output signal Pout is set as follows:-
Valve open 0 = 0
A V Pout + BV
Valve closed 1 = 1
A V Pout + BV
Where Pout is the equivalent output signal in mA Refer to Figure 7 for typical settings.
The position of CVAL in the model is critical and the rules can be summarized:-
1. It requires inlet (Pi) and outlet (Po ) pressures to be specified where Pi is taken from the inlet
stream. Po can be specified directly or overtaken indirectly by an assigned UnitOp in the model.
2. A mass balance must be maintained around CVAL. To achieve this, locate immediately after a
Feed Arrow (direct flow adjust) or after Stream Reference (SREF) or Divider (DIVI) (indirect
flow regulation). Dynamic Vessel, Dynamic Reactor and Dynamic Column can also be
assigned for indirect flow regulation. The optimal mass flowrate transfer is used to set up
Indirect Flowrate Regulation.
HTXR is a steady state UnitOp. To use in Dynamic simulation specify Overall Heat Transfer
Coefficient (U) and Heat Transfer Area (A) only. Tubeside and shellside pressure drops can be
added.
When rating an existing unit use CCTherm to determine the UA for the duty being considered. This
enables confirmation of manufacturer’s design data. CCTherm option will not run in Dynamic
simulations.
MNL029 05/01
Page 22 of 23
Process Modelling and Control of
Batch Reactors in the Fine Chemicals Industry
Initial Charge
Reactor Specification
Jacket/Coil Specification
Unbaffled jacket calculated outside film coefficient (ho ) does not assume turbulence. If mixing
nozzles fitted enter appropriate ho from Appendix I.
Set initial conditions in jacket for pressure and temperature.
If jacket is full set initial liquid fraction at one (1).
If this liquid fraction is not set the model assumes the jacket is empty.
Dynamic Menu
Plot
Dynamic run curves for variables to be studied are obtained via Plot and Dynamic History options.
MNL029 05/01
Page 23 of 23
REACTOR CONTROL SYSTEMS Figure 1
INDIRECT JACKET
HEAT/COOL
BATCH
REACTOR
NC NO
Heater Cooler
NO NC SCHEME 3
Pump
INDIRECT JACKET HEATING SYSTEM SCHEME 3 Figure 2
INDIRECT JACKET COOLING SYSTEM SCHEME 3 Figure 3
CONDENSER CONTROL SYSTEM
Figure 4
REACTOR
Inlet temperature control OVERHEADS
prevents freezing
T
T
COOLANT FO COOLANT
RUNDOWN
PUMP
CONDENSER CONTROL SYSTEM MODEL Figure 5
CONTROL VALVE CHARACTERISTICS
Figure 6
100
90
80
70
VALVE STROKE %
60
LINEAR
50 EQUAL PERCENTAGE
QUICK OPENING
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
FLOW %
CONTROLLER & CONTROL VALVE ACTION Figure 7
180 400
160 300
140
Temperature (°C)
200
120
Heat (MJ/h)
100
100
0
80
-100
60
40 -200
20 -300
0 -400
0 0.2 0.4 0.6 0.8 1 1.2 0 0.2 0.4 0.6 0.8 1
Tu=24m Time (h) Time (h)
1600
Heat Transfer Coefficient
1400
1200
1000
(W/m2K)
800
600
400
200
0
0 0.2 0.4 0.6 0.8 1 1.2
Time (h)
1600L REACTOR BOIL UP/EMISSION Graph 2
Toluene Total
12
10
0
0 0.2 0.4 0.6 0.8 1
Time (h)
Total Flow
600
500
Boil Up Rate (kg/h)
400
300
200
100
0
0 0.2 0.4 0.6 0.8 1
Time (h)
1600L HASTELLOY REACTOR COOLDOWN Graph 3
120 60
100 40
80
20
60
0
40
-20
20
0 -40
-20 -60
0 0.5 1 1.5 2 0 0.2 0.4 0.6 0.8 1
Time (h) Time (h)
1600 80
1400 70
Heat Transfer Coefficient
60
Temperature (°C)
1200
50
1000 40
(W/m2K)
800 30
600 20
10
400
0
200 -10
0 -20
0 0.2 0.4 0.6 0.8 1 1.2 0 0.2 0.4 0.6 0.8 1
Time (h) Time (h)
CONDENSER MODEL CONTROLLER TUNING Tu Graph 4
40
30
Temperature(°C)
20
0.122h
10
-10
-20
0 0.2 0.4 0.6 0.8 1
Time(h)
CONDENSER MODEL CONTROLLER TUNING Graph 5
Temperature(°C)
30
20
10
-10
-20
0 0.2 0.4 0.6 0.8 1
Time(h)
40
30
20
10
0
-10
-20
0 0.2 0.4 0.6 0.8 1
Time (h)
CHEMCAD SUITE
CC-DYNAMICS
(CC-DCOLUMN & CC-ReACS)
User’s Guide
YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE USING
THIS PACKAGE. USING THIS PACKAGE INDICATES YOUR ACCEPTANCE OF THESE TERMS AND
CONDITIONS.
The enclosed proprietary encoded materials, hereinafter referred to as the Licensed Program(s), are the
property of Chemstations Inc. and are provided to you under the terms and conditions of this License
Agreement. Included with some Chemstations Inc. Licensed Programs are copyrighted materials owned
by the Microsoft Corporation, Rainbow Technologies Inc., and InstallShield Software Corporation. Where
such materials are included, they are licensed by Microsoft Corporation, Rainbow Technologies Inc., and
InstallShield Software Corporation to you under this License Agreement. You assume responsibility for the
selection of the appropriate Licensed Program(s) to achieve the intended results, and for the installation,
use and results obtained from the selected Licensed Program(s).
LICENSE GRANT
In return for the payment of the license fee associated with the acquisition of the Licensed Program(s) from
Chemstations Inc., Chemstations Inc. hereby grants you the following non-exclusive rights with regard to
the Licensed Program(s):
Use of the Licensed Program(s) on more than one machine. Under no circumstance is
the Licensed Program to be executed without either a Chemstations Inc. dongle
(hardware key) or system authorization code.
You agree to reproduce and include the copyright notice as it appears on the Licensed Program(s) on any
copy, modification or merged portion of the Licensed Program(s).
THIS LICENSE DOES NOT CONVEY ANY RIGHT TO USE, COPY, MODIFY OR TRANSFER THE
LICENSED PROGRAM(S) OR ANY COPY, MODIFICATION OR MERGED PORTION THEREOF, IN
WHOLE OR IN PART, EXCEPT AS EXPRESSLY PROVIDED IN THIS LICENSE AGREEMENT.
TERM
This License Agreement is effective upon acceptance and use of the Licensed Program(s) until terminated
in accordance with the terms of this License Agreement. You may terminate the License Agreement at any
time by destroying the Licensed Program(s) together with all copies, modifications, and merged portions
thereof in any form. This License Agreement will also terminate upon conditions set forth elsewhere in this
Agreement or automatically in the event you fail to comply with any term or condition of this License
Agreement. You hereby agree upon such termination to destroy the Licensed Program(s) together with all
copies, modifications and merged portions thereof in any form.
i
LIMITED WARRANTY
The Licensed Program(s), i.e. the tangible proprietary software, is provided "AS IS" WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, AND EXPLICITLY EXCLUDING ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The
entire risk as to the quality and performance of the Licensed Program(s) is with you.
Some jurisdictions do not allow the exclusion of limited warranties, and, in those jurisdictions the above
exclusions may not apply. This Limited Warranty gives you specific legal rights, and you may also have
other rights which vary from one jurisdiction to another.
Chemstations Inc. does not warrant that the functions contained in the Licensed Program(s) will meet your
requirements or that the operation of the program will be uninterrupted or error free.
Chemstations Inc. does warrant, however, that the diskette(s), i.e. the tangible physical medium on which
the Licensed Program(s) is furnished, to be free from defects in materials and workmanship under normal
use for a period of ninety (90) days from the date of delivery to you as evidenced by a copy of your receipt.
Chemstations Inc. warrants that any program errors will be fixed by Chemstations Inc., at Chemstations'
expense, as soon as possible after the problem is reported and verified. However, only those customers
current on their update/maintenance contracts are eligible to receive the corrected version of the program.
ENTIRE AGREEMENT
This written Agreement constitutes the entire agreement between the parties concerning the Licensed
Program(s). No agent, distributor, salesman or other person acting or representing themselves to act on
behalf of Chemstations Inc. has the authority to modify or supplement the limited warranty contained
herein, nor any of the other specific provisions of this Agreement, and no such modifications or
supplements shall be effective unless agreed to in writing by an officer of Chemstations Inc. having
authority to act on behalf of Chemstations Inc. in this regard.
LIMITATIONS OF REMEDIES
Chemstations' entire liability and your exclusive remedy shall be:
a) The replacement of any diskette not meeting Chemstations' "Limited Warranty" as
defined herein and which is returned to Chemstations Inc. or an authorized
Chemstations dealer with copy of your receipt, or
b) If Chemstations Inc. or the dealer is unable to deliver a replacement diskette which is
free of defects in materials or workmanship, you may terminate this License Agreement
by returning the Licensed Program(s) and associated documentation and you will be
refunded all monies paid to Chemstations Inc. to acquire the Licensed Program(s).
IN NO EVENT WILL CHEMSTATIONS INC. BE LIABLE TO YOU FOR ANY DAMAGES, INCLUDING ANY
LOST PROFITS, LOST SAVINGS, AND OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OR INABILITY TO USE THE LICENSED PROGRAM(S) EVEN IF
CHEMSTATIONS INC. OR AN AUTHORIZED CHEMSTATIONS DEALER HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM BY ANY OTHER PARTY.
ii
SOME JURISDICTIONS DO NOT PERMIT LIMITATION OR EXCLUSION OF LIABILITY FOR
INCIDENTAL AND CONSEQUENTIAL DAMAGES SO THAT THE ABOVE LIMITATION AND
EXCLUSION MAY NOT APPLY IN THOSE JURISDICTIONS.
GENERAL
The initial license fee includes one (1) year of support, maintenance, and enhancements to the program.
After the first one (1) year term, such updates and support are optional at the then current update fee.
Questions concerning this License Agreement and all notices required herein shall be made by contacting
Chemstations Inc. in writing at Chemstations Inc., 2901 Wilcrest, Suite 305, Houston, Texas, 77042, by
telephone, 713-978-7700, or by Fax, 713-978-7727.
DISCLAIMER: CC-STEADY STATE, CC-BATCH, CC-DYNAMICS, CC-THERM, CC-FLASH,
CC-SAFETY NET, CC-POLYMERS, CC-LANPS
Copyright(c) Chemstations Inc., 2005, all rights reserved.
This proprietary software is the property of Chemstations, Inc. and is provided to the user pursuant to a
Chemstations Inc. program license agreement containing restrictions on its use. It may not be copied or
distributed in any form or medium, disclosed to third parties, or used in any manner except as expressly
permitted by the Chemstations Inc. program license agreement.
THIS SOFTWARE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED. NEITHER CHEMSTATIONS INC. NOR ITS AUTHORIZED REPRESENTATIVES SHALL
HAVE ANY LIABILITY TO THE USER IN EXCESS OF THE TOTAL AMOUNT PAID TO
CHEMSTATIONS INC. UNDER THE CHEMSTATIONS INC. PROGRAM LICENSE AGREEMENT FOR
THIS SOFTWARE. IN NO EVENT WILL CHEMSTATIONS INC. BE LIABLE TO THE USER FOR ANY
LOST PROFITS OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF USE
OR INABILITY TO USE THE SOFTWARE EVEN IF CHEMSTATIONS INC. HAS BEEN ADVISED AS
TO THE POSSIBILITY OF SUCH DAMAGES. IT IS THE USERS RESPONSIBILITY TO VERIFY THE
RESULTS OF THE PROGRAM.
iii
CC-DYNAMICS Version 5.5
TABLE OF CONTENTS
Introduction ............................................................................................................................................1
Installation ............................................................................................................................................3
Accessing CC-DYNAMICS .........................................................................................................................3
CHEMCAD and CC-DYNAMICS ................................................................................................................5
Main Features of CC-DYNAMICS...............................................................................................................6
Setting Up A CC-DYNAMIC Simulation: An Overview................................................................................7
About Dynamic Time and Dynamic Data Files ...........................................................................................7
Turning on the Dynamic Mode....................................................................................................................8
The Dynamics Menu.................................................................................................................................10
Set Run Time ...............................................................................................................................11
Run From Initial State ..................................................................................................................15
Run From Current State...............................................................................................................15
Restore To Initial State.................................................................................................................15
Record Streams and Record Unit Operations ..............................................................................15
Record Process............................................................................................................................15
Save As Initial State .....................................................................................................................15
Help..............................................................................................................................................15
Reviewing Dynamic Results .....................................................................................................................16
Plotting Dynamic Results..........................................................................................................................16
Dynamic Column History (CC-DCOLUMN) ..................................................................................17
Dynamic Stream History ..............................................................................................................18
The Batch Reactor Model (CC-ReACS) ...................................................................................................20
Overview ......................................................................................................................................20
The Batch Reactor (Reaction Side) Mass Balance ......................................................................22
The Reaction Rate Equations ......................................................................................................23
The Jacket/Coil Mass Balances ...................................................................................................26
The Reactor Heat Balance...........................................................................................................26
The Jacket/Coil Heat Balances ....................................................................................................29
Heat Transfer Calculation Details.................................................................................................29
The Pressure Calculation.............................................................................................................34
Jacket/Coil Pressure Calculation..................................................................................................35
Relief Calculations .......................................................................................................................36
Batch Reactor Input ..................................................................................................................................36
The Batch Reactor Menu..........................................................................................................................37
The Reactor Initial Charge Dialog Box ..................................................................................................... 37
The Batch Reactor General Information Dialog Box................................................................................. 38
General Input ............................................................................................................................... 39
Semi-Batch Input ......................................................................................................................... 42
Convergence Input....................................................................................................................... 42
Rate Equation Units Dialog Box ............................................................................................................... 44
The Reaction Kinetics Dialog Box ............................................................................................................ 45
T/Q Profile Dialog Box .............................................................................................................................. 47
Reactor Specifications Dialog Box ........................................................................................................... 49
Page One-Geometry Input........................................................................................................... 49
Page Two-Process Side .............................................................................................................. 51
Jacket/Coils Specifications Dialog Box ........................................................................................53
External Feed Schedule Dialog Box......................................................................................................... 55
Product Draw Schedule Dialog Box ......................................................................................................... 56
Setting Up Schedules and Profiles in CC-ReACS .................................................................................... 57
Scheduling Input Conventions and Procedures ........................................................................... 57
Special Points Regarding Individual Schedule/Profile Variable ................................................... 58
Relief Dialog Box...................................................................................................................................... 60
Batch Reactor Run Time Plot Options Dialog Box ................................................................................... 61
Dynamic Column Models.......................................................................................................................... 62
Overview...................................................................................................................................... 62
Dynamic Columns Input ........................................................................................................................... 63
The Dynamic Column Menu ..................................................................................................................... 63
The General Information Dialog Box ........................................................................................................ 64
The Startup Parameters Dialog Box......................................................................................................... 66
Startup Charge ......................................................................................................................................... 67
The Column Holdups Dialog Box ............................................................................................................. 68
The Dynamic Column Specifications Dialog Box...................................................................................... 69
Condenser Input .......................................................................................................................... 70
Reboiler Input .............................................................................................................................. 72
The Reflux Control Dialog Box ................................................................................................................. 74
Valve Input................................................................................................................................... 75
Calculated Results ....................................................................................................................... 77
Controller Input ............................................................................................................................ 77
Sensor Information....................................................................................................................... 79
Calculated Results ....................................................................................................................... 80
The Column Metal Heat Transfer Dialog Box ........................................................................................... 81
The Record Stages Dialog Box ................................................................................................................ 81
The Plot Options Dialog Box .................................................................................................................... 82
The PID Controller/Control Valve Model CC-DYNAMICS ........................................................................ 83
Determine the Value of the Measured Variable & Compare to Set Point .....................................84
Calculate the Sensor Output Signal .............................................................................................84
The PID Control Function.............................................................................................................85
The Valve Position Equation ........................................................................................................86
The Control Valve Flowrate Calculation .......................................................................................87
Control Valve Dialog Box..........................................................................................................................93
Parameter Definitions...................................................................................................................94
Topology ......................................................................................................................................99
PID Controller Dialog Box.........................................................................................................................99
Parameter Definitions Page One................................................................................................101
Controller/Sensor Function..............................................................................................102
Measured Object .............................................................................................................103
Parameter Definitions Page Two................................................................................................105
Optional Active Time Specs ............................................................................................105
For Split Range Control ...................................................................................................106
Calculated Results...........................................................................................................106
The Dynamic Vessel Model ....................................................................................................................106
The Pressure Calculations .........................................................................................................108
The Calculation Modes ..............................................................................................................109
Maintaining Liquid Levels by Decanting .....................................................................................110
The Vapor Flow Models .............................................................................................................112
Relief Vent Calculations .............................................................................................................113
The Dynamic Vessel Dialog Box.............................................................................................................113
Parameter Definitions Page One (General)................................................................................114
Geometry.........................................................................................................................114
Vessel Thermal Mode......................................................................................................115
Initial Conditions ..............................................................................................................116
Optional Inputs ................................................................................................................116
Parameter Definitions Page Two (Outlet Flow) ..........................................................................117
Parameter Definitions Page Three (Relief Device).....................................................................118
Pressure Data .................................................................................................................119
For Vapor Relief Only ......................................................................................................120
For Liquid Relief Only ......................................................................................................120
Parameter Definitions Page Four (Calculated Results)..............................................................121
Topology ....................................................................................................................................122
Other Unit Operations.............................................................................................................................122
The Ramp Controller ..............................................................................................................................122
Parameter Definitions.................................................................................................................122
The Time Delay Unit Operation ..............................................................................................................124
Topology ....................................................................................................................................125
The Time Switch Unit Operation............................................................................................................. 125
Topology .................................................................................................................................... 126
Steady State Unit Operations ................................................................................................................. 126
Dynamic Techniques .............................................................................................................................. 127
Fundamental Techniques ....................................................................................................................... 128
The Control Valve, CVAL........................................................................................................... 128
How the Control Valve Modifies the Flowrate ............................................................................ 128
How to Modify the Valve Position............................................................................................... 133
Sizing, Initial State of Control Valve, Troubleshooting ............................................................... 139
What is a Control Loop? ............................................................................................................ 140
How to Specify a Transmitter..................................................................................................... 141
How to Specify Error Function ................................................................................................... 142
How to Specify Parameters of PID............................................................................................. 143
Special Parameters of the PIDC Model ..................................................................................... 145
Control Structures ...................................................................................................................... 145
What is the Location of the PID Controller in the Flowsheet ...................................................... 146
How to Use Cascade Control System........................................................................................ 149
How to Define a Set Point Tracking System .............................................................................. 151
How to Define a Set Point Control System ................................................................................ 152
Applications of Steady State Models in Dynamic Simulation ..................................................... 155
How to Use the HTXR Model.....................................................................................................155
How to Use the Pipe Model ....................................................................................................... 157
Dynamic Simulation of a Distillation Column .......................................................................................... 159
Which Icon of SCDS Should You Use in a Dynamic Simulation? .............................................. 159
Column Dynamics Without Any Controller ................................................................................. 162
How to Install Control Loops for a Column................................................................................. 177
How to Use the Built-In Models of Dynamic Column Module..................................................... 186
How to Use Dynamic Column Model For Control of Condenser and Reflux .............................. 192
Dynamic Column Model For Batch Distillation Systems, Startup Problems............................... 207
Rate Regression..................................................................................................................................... 216
Input Discussion ..................................................................................................................................... 217
Select Parameters Screen Dialog Box....................................................................................... 218
Parameter Definitions-Page One ............................................................................................... 219
Parameter Definitions-Page Two ............................................................................................... 220
Import Profile ............................................................................................................................. 221
Parameter Definitions ................................................................................................................ 221
Input/Edit Rate Profile ................................................................................................................ 222
Parameter Definition .................................................................................................................. 223
Check Initial Estimations............................................................................................................ 224
Perform Regression ................................................................................................................... 224
Plot Results ................................................................................................................................224
Using Rate Regression...........................................................................................................................225
Determining Constants...............................................................................................................226
Parameter Selection...................................................................................................................226
Build A Batch Reactor Flowsheet...............................................................................................226
Specify The Initial Charge ..........................................................................................................226
Entering The General Parameters .............................................................................................227
Specify The Reactions ...............................................................................................................227
Call The Rate Regression Menu ................................................................................................227
Select The Parameters To Be Calculated ..................................................................................227
Build The Regression Data Sets ................................................................................................228
Specify Which Data Sets Are To Be Used In The Regression Analysis.....................................229
Check The Initial Estimates........................................................................................................229
Perform The Regression ............................................................................................................229
Troubleshooting Regressions.....................................................................................................229
Plot The Results.........................................................................................................................230
Examples ........................................................................................................................................230
The Rateregressrc1 Problem .....................................................................................................230
The Rateregressrc1 Problem-Analyzing The Results ................................................................241
Appendix I-Agitator Coefficients For The Seader-Tate Equation ............................................................242
Appendix II-User Added Kinetic Rate Expressions .................................................................................243
Overview ....................................................................................................................................243
Basic Use...................................................................................................................................243
Additional Comments .................................................................................................................246
Appendix III-Static Head In The Dynamic Vessel ...................................................................................248
Overview ....................................................................................................................................248
Basic Use...................................................................................................................................248
Inlet and Outlet Nozzles .............................................................................................................249
Appendix IV-Reactor Database ..............................................................................................................252
CC-DYNAMICS Version 5.5 User’s Guide
INTRODUCTION
3
TC
2 1
1 5 6
5
2
TC
4
3 7 8
CC-ReACS is designed to be used at all levels and stages of batch chemical process design and
analysis. It can be used to:
• Analyze experimental data to determine mechanisms and rates.
• Perform adiabatic or isothermal simulations, which are independent of equipment configuration,
control requirements, and heat transfer considerations.
1
User’s Guide CC-DYNAMICS Version 5.5
• Perform detailed simulations, which include the equipment, control and heat transfer aspects of
the process.
• Simulate simple flowsheets (one reactor with or without supporting equipment) or complex
systems (many reactors with associated equipment).
A typical application of CC-DCOLUMN is depicted below:
CC-DCOLUMN is designed to be used at all levels and stages of distillation process design and
analysis. It can be extremely useful to:
• Quantify the requirements of operability, control loop tuning, changes in throughput or ambient
conditions, safety demands, etc.
• Perform detailed simulations, which include the equipment and control aspects of the process
• Simulate the effects of disturbances, startups, and shutdowns on key process variables.
• Perform simulations, which are independent from control requirements.
• Validate control schemes.
2
CC-DYNAMICS Version 5.5 User’s Guide
By combining CC-ReACS and CC-DCOLUMN into CC-DYNAMICS simulations of batch reactors with
columns becomes possible:
11 4
2 3 LC
6
22 13
FC 7 8 21
25 14
15 24 23 7
10 9
16 15 4
3
6
8
12
9
PC
1 18 19 20
11 12 13 5
10
17 2
Throughout this manual we will be using the terms CC-DYNAMICS, CC-ReACS, and CC-DCOLUMN to
refer to our software. Some users may have purchased only part of CC-DYNAMICS, and it is important
to know what features are and are not available in each package. When we use the term CC-
DYNAMICS, the documentation is referring to features common to both CC-ReACS and CC-DCOLUMN,
for example PID controllers. When we use the term CC-ReACS, we are referring to features only
available in the CCReACS part of CC-DYNAMICS, such as Batch Reactors. When referring to CC-
DCOLUMN, we are documenting features available in the CC-DCOLUMN part of CC-DYNAMICS.
INSTALLATION
CC-DYNAMICS is completely integrated with the CHEMCAD Suite and does not run in a separate
interface. CC-DYNAMICS is always installed with the CHEMCAD Suite. If the any program of the
CHEMCAD Suite has been installed there is not any special procedure to install CC-DYNAMICS. The
use of CC-DYNAMICS only depends on the user’s license (See “Accessing CC-DYNAMICS” below).
Please refer to the installation section of the CC-STEADY STATE Users Guide.
ACCESSING CC-DYNAMICS
CC-DYNAMICS is part of the CHEMCAD engineering suite. To access your license for CC-DYNAMICS,
start CHEMCAD. And you will be shown to the License Selection screen:
3
User’s Guide CC-DYNAMICS Version 5.5
This screen allows you to select which licensing methods you would like to use to authorize your use of
CC-DYNAMICS. The default settings shown will look for all available licenses using System
Authorization, Sentinel Scribe, or SuperPro Dongles. If you use a network shared license such as a
License Manager, the correct settings would be like so:
Note that network licensing systems allow you to select which products you wish to look for licenses. In
the above example the License manager will look for licenses for all products (see the “all products”
checkbox). Alternately you could request that CHEMCAD only look for the CC-DCOLUMN and CC-
ReACS licenses:
4
CC-DYNAMICS Version 5.5 User’s Guide
Once you press OK on the License Selection screen, you should get a licensed products screen showing
what licenses you ended up with:
CC-DYNAMICS is a module within the CHEMCAD system. As such, it uses many of the features of
CHEMCAD. These include:
• The flowsheet drawing features.
5
User’s Guide CC-DYNAMICS Version 5.5
This guide describes the use of and technical details of CC-DYNAMICS. These include:
Common CC-DYNAMICS features:
• The PID control system
• The dynamic vessel
• Miscellaneous dynamic unit-operations – Ramp, Time Delay, Task, Time Switch
• Other unit operations which can be used in CC-ReACS simulations
• The dynamics menu
CC-ReACS features:
• The batch reactor
• The rate regression utility
CC-DCOLUMN features:
• The dynamic model of SCDS distillation UnitOp.
• The dynamic model of TPLS distillation UnitOp.
6
CC-DYNAMICS Version 5.5 User’s Guide
Many of the steps listed below are the same in a dynamic simulation as in a steady state simulation (CC-
STEADY STATE).
The steps for setting up a dynamic flowsheet are:
1. Start a new job
2. Select engineering units
3. Turn on the dynamics mode
4. Draw the flowsheet
5. Select components
6. Select thermodynamics options
7. Specify feed streams and initial stream conditions
8. Specify UnitOps
9. Run the simulation
10. Review the results with RESULTS and PLOT
11. Re-run the simulation or extend the run from the current simulation time
12. Generate reports
Most steps and are described in detail in the CC-STEADY STATE User’s Guide and in the On-line Help
System. Those descriptions will not be repeated in this guide.
Dynamic simulations perform a calculation of the entire flowsheet every time step. A flowsheet has two
time conditions: initial time (dynamic time = 0:00) and current time (dynamic time during calculation).
The large amount of calculated data can quickly becoming overwhelming. To reduce size of data files,
variables are not recorded by default. The user can specify to record stream or unit operation variables
at all times, and / or to record the entire flowsheet at specific times.
CC-DYNAMICS maintains several sets of flowsheet data files in order to manage all of the situations and
manipulations the user may choose to execute. These files fall into the following categories:
7
User’s Guide CC-DYNAMICS Version 5.5
Activate dynamic mode on the Convergence dialog box. The command for this dialog is under the Run
command on the main menu bar. Note that some actions (such as placing a batch reactor on a
flowsheet) will automatically set this for you.
Procedure:
Click the Run command on the main menu bar. Click on the Convergence option at the top of the
menu, the following screen will appear:
8
CC-DYNAMICS Version 5.5 User’s Guide
Select the Steady State/Dynamics combo box. Scroll down and select Dynamics as shown in the
picture below.
Click OK to save the changes. As a result the steady-state Run button will be turned off and the
dynamic buttons on the toolbar will be turned on. They will be colored and no longer shaded (see picture
below).
Also some dynamics commands will be activated such as the Dynamics command on the Run menu,
the dynamic plot commands on the Plot menu, and the dynamic results commands on the Results
menu (see pictures below). The Dynamics command on the Run menu is discussed in the next section.
9
User’s Guide CC-DYNAMICS Version 5.5
Exit:
Exit dynamics menu without executing simulator.
10
CC-DYNAMICS Version 5.5 User’s Guide
This command is used to set the stop criteria of the dynamics run and to specify the time step size (how
often the flowsheet equations are integrated). These items must be specified for the calculation to
proceed. Clicking this option will cause the following Set Simulation Run Time dialog box to be
displayed. Please make note of the following:
11
User’s Guide CC-DYNAMICS Version 5.5
1. More than one operating step can be specified. If a run is made from time zero (i.e., the initial
state), all specified operating steps will be run. If the simulation is being run from the current state,
then only those operating steps beyond the current time will be run.
Operating steps can be added at any time, so this feature provides a facility for extending the
dynamic simulation indefinitely.
2. The time step size is specified in the Step size field.
3. Operating step run time limits can be specified as fixed times or as events. These stopping events
can be when a UnitOp or Stream variable is equal to, greater than, less than, limited from below or
limited from above by a specified value.
The Dynamic Run Time Schedule dialog box has two pages that look like this:
GENERAL INPUT
Number of operating steps:
The number of operating steps to be simulated must be entered in this field. Otherwise, the program will
only run the first step. Up to ten operating steps can be specified. For each operating step a stop criteria
can be specified.
Current Time:
Displays the current simulated time. That is, the time at the end of the last simulated operating step.
Step X:
For each operating step a dialog box displaying the following fields will be provided.
Using the stop criteria, you can stop the simulation after a specified amount of time, or when a stream or
equipment variable reaches a certain value, minimum or maximum.
12
CC-DYNAMICS Version 5.5 User’s Guide
Stop When:
This field identifies the type of stop criteria to be used for this operating stop. Options are:
• Time – stop when the specified run time has been reached.
• Stream – stop when a specified stream variable has met the stop criteria
• Equipment – stop when a specified equipment or UnitOp variable has met the stop criteria.
Run Time:
If the stop criteria are to be time, the duration of the operating step must be entered in this field (in
minutes).
Step Size:
The step size determines the frequency of integration during the simulation. Step size is specified in
minutes of simulated time. For example, if the operating step is to calculate 100 minutes of simulated
time, and the step size is 2 minutes, the program will integrate the flowsheet equations 50 times during
the simulation.
The step size selected will have an impact on the accuracy of the results and the speed of the
calculation. Smaller time steps will produce smaller errors, but will require more time to make the run.
Step size can be different for every operating step if desired.
ID Number:
If the Stop When selection is “Stream” or “Equipment”, the ID number of the relevant stream or
equipment must be entered in this field.
Variable Number:
If the Stop When selection is “Stream” or “Equipment”, the number of the relevant stream or equipment
variable must be entered in this field. Variable numbers are listed in the on-line help.
Variable Unit:
If the stop criteria are to be based upon a stream or equipment variable, then it is advisable to identify
the type of variable which has been selected. Variable Type identifies the engineering units to be
applied to the variable. If the variable type is identified, the program will apply the global flowsheet
13
User’s Guide CC-DYNAMICS Version 5.5
engineering units to the Stop Value. If the Variable type is not identified, then the program will apply
internal engineering units to the Stop Value.
For example, if the stop criteria is to be based upon the temperature of stream 5, and the global
flowsheet units for temperature is degrees Celsius, then the “Temperature” option should be selected in
the Variable Unit field. This will tell the program that the Stop Value has units of degrees Celsius. If
‘Temperature” is not selected, the program will assume the Stop Value is specified in degrees Rankine
(CC-DYNAMICS’ internal units for temperature).
Component:
If a component purity or flowrate criteria is chosen, identify the relevant component from the list.
Stop Mode:
The stop mode is the numerical operator, which is used to compare the current value of the stopping
variable to the stop value. When:
{Current value of stopping variable} operator {Stop Value} is true
then the operating step is over.
The following operators are available:
• Equal to (=): This operator will end the operating step when the current value of the stopping
variable is within a specified tolerance of the stop value.
• Greater than (>): This operator will end the operating step when the current value of the
stopping variable exceeds the stop value.
• Less than (<): This operator will end the operating step when the current value of the stopping
variable is below the stop value.
• Minimum: This operator will end the operating step when the value of the stopping variable
passes through a minimum.
• Maximum: This operator will end the operating step when the value of the stopping variable
passes through a maximum.
Stop Value:
This is the numerical value of the stopping criteria. If “Stream” or “Equipment” was selected in the Stop
When field, the stop value must be specified. If “Time” was selected in the Stop When field, the stop
value field is not used.
Stop Tolerance:
This is the acceptable tolerance to be used when the “equal to” Stop Mode is used.
Calculated Run Time:
If “Stream” or “Equipment” was selected in the Stop When field, the program will calculate the time it
took to complete the operating step. That value will be displayed in this field. Units are always minutes.
14
CC-DYNAMICS Version 5.5 User’s Guide
Selecting this option will cause the program to return to the initial conditions and rerun the entire
simulation. All results from previous simulations will be discarded.
Selecting this option will continue the simulation from the current state, i.e., from the last calculated
result. In order to use this option, an operating step beyond the current state must be scheduled on the
Set runtime option above.
This option will restore the initial conditions specified. All previous calculations will be discarded. It is
necessary to restore to the initial state in order to change certain flowsheet variables. By default, once a
simulation has started, CC-DYNAMICS will not allow you to change any variables. You can change this
by going to the Run->Convergence menu and selecting “Allow dynamic editing anytime.”
Unless otherwise specified the user, CC-DYNAMICS will only record the histories of batch reactors and
dynamic columns. For all other UnitOp and streams only the initial and final variable values are
recorded. If desired, to view, plot, or report the historical results of these other UnitOps and streams,
then you must instruct the program to do so using the Record Streams and Record Unit Operations
menu options. Each options calls a dialog box in which you can list the streams and/or UnitOps that you
wish recorded. Selections can be typed in or chosen with the mouse. Once an item is selected, then all
of the variables associated with that item are recorded.
RECORD PROCESS
This dialog box is used to identify times (simulated) when the entire process is to be recorded.
Recording the entire process means that every variable in the process will be written to disk. Use this
option with caution, it can slow down calculations and greatly increase the storage space required for
your simulation.
Selecting this option will cause the program to set the current conditions of the dynamic run as the new
initial condition. All parameters from the previous initial state will be discarded and it will not be possible
to recover data for the previous state.
HELP
This button will open the help facility of the dynamics menu.
15
User’s Guide CC-DYNAMICS Version 5.5
Dynamic results can be obtained on the Results menu. The user should select one of three general
dynamic options at the bottom of the Results command: Dynamic Column History, Dynamic Stream
History and Dynamic UnitOp History.
To plot a recorded variable there are two options. The user can either use the dynamic plot commands
on the Plot menu or use the dynamic results buttons on the tool bar.
Stream histories and UnitOp histories are plotted using the Batch Reactor/DVSL History, Dynamic
Column History, Dynamic Stream History, and UnitOp History options on the Plot menu. With the
16
CC-DYNAMICS Version 5.5 User’s Guide
exception of batch reactors and dynamic columns, you must indicate to the program that a given
stream or UnitOp is to be recorded before the simulation is run, otherwise the data will not be
available to plot.
Dynamic plot results can be obtained by selecting one of the dynamic options at the bottom of the Plot
menu or by clicking on the Dynamic Plots buttons on the menu bar (see pictures below):
After running a Dynamic Column, you may plot several of the recorded values using this option. Once
you select this option, you will be asked to select the dynamic column on your flowsheet. When you click
OK, you will see the following dialog box:
Variable to be plotted
Define the variable to be plotted on the y-axis. Select one from the pull-down list.
Object to be plotted
Select one of the following. This field may not be needed if the variable specified above does not require
a location (e.g., reflux ratio).
! Distillate
! Bottom
! Stage
17
User’s Guide CC-DYNAMICS Version 5.5
Stage Information
If a plot for one of the stages in the column is desired, specify the following:
! Stage No. – Enter the stage number for which the properties will be plotted.
! Phase – Indicate whether you are plotting data for the liquid or vapor phase.
! Time Unit / Frequency
Time Unit
Specify what time unit you want to use for the x-axis and the frequency you want plotted (hr, min, sec).
Plot Frequency
This is the number of time steps between plotting results. If the simulation integration time step is one
minute and the plot frequency is five, the results will be plotted every five (simulated) minutes.
Y-axis min/max values
CC-DCOLUMN allows tuning up the range for the plot of a recorded variable. Specify a minimum and
maximum for the y-axis of your plot
Components to be plotted
You may plot up to ten components by selecting them in this section. If the plot you select is any related
to flow or concentration (i.e. mole/mass/mass frac/ etc) you may want to select the component(s) to be
plotted. Select components from the pull-down list.
After running a dynamic flowsheet, you can plot stream variables versus time, if you have specified that
a stream be recorded in the Dynamics Menu.
To plot a stream variable go to the Plot menu and select the Dynamic Stream History option. You may
also click on the Dynamic Stream History button on the menu bar.
18
CC-DYNAMICS Version 5.5 User’s Guide
Stream number
Define the stream number to be plotted. You must have specified that this stream be recorded.
Plot Frequency/Time Unit
Specify the frequency and time for the stream variables to be plotted.
Composition / Components
Specify whether or not you desire a composition/time plot and the units you desire (i.e. mole/mass/mass
frac/ etc). Also specify which components are to be plotted.
19
User’s Guide CC-DYNAMICS Version 5.5
Stream Variables
Click on the Plot Stream Properties tab. The following screen will appear:
Specify which stream variables to plot by using the check boxes next to the variable names.
Click OK to save the changes and open the stream property plot CC-DCOLUMN will create.
OVERVIEW
20
CC-DYNAMICS Version 5.5 User’s Guide
V1
F2
F1
U1
U2 Pr
Q
Q
U3
A=>B
Recirculation
L1
Figure 1
The batch reactor UnitOp simultaneously solves the following sets of equations:
1. For the reaction mass it solves:
• The mass balance which involves up to two feeds streams, one vapor and one liquid outlet
stream (both optional), the reaction rate equation, and the phase equilibrium (flash)
relationships.
• The heat balance which includes the enthalpies of the feeds, outlets and holdup, the heat of
reaction, the heat transferred from/to the jackets and coils, agitator horsepower and ambient
heat losses/gains.
• The pressure calculation (optional) which uses the reactor geometry and the phase equilibrium
relations to determine pressure and rate.
2. For the jackets and coils it solves:
• The mass balance including the holdup and up to three utility streams (in and out) per jacket or
coil.
• The heat balance, which includes the enthalpies of the holdup, the inlet and outlet, streams, the
heat transferred to (from) the reaction mass, and ambient losses (gains).
21
User’s Guide CC-DYNAMICS Version 5.5
• The pressure calculation (determination of the dynamic pressure inside the jacket/coil) via
energy and phase equilibrium equations.
The model has the following major features:
• Unlimited number of simultaneous reactions.
• Arrhenius or Langmuir-Hinshelwood, as well as user defined forms of the rate equation.
• Any combination of jackets, external coils, and/or internal coils on the reactor vessel (maximum
of five per reactor).
• Heat-cool-chill can be simulated.
• Reactor pressure can be fixed or calculated.
• Heat transfer coefficients can be specified or calculated.
• Jackets may be baffled or unbaffled, and agitating nozzles can be used.
• External coils may be dimpled or half pipe.
• Feed and product flow rates may be scheduled, controlled, or, for vapor vents, calculated.
• Batch, semi-batch, and continuous operation can be simulated.
• PID control systems can be used.
• Run time plots can be generated.
• Heat transfer can be scheduled or calculated.
• Phase equilibrium can be vapor-liquid or vapor-liquid-liquid.
• The thermal mode of calculation can be isothermal, adiabatic, isothermal with a temperature
schedule, adiabatic with a heat load schedule, or calculated using heat transfer methods.
• Agitator characteristics can be user specified.
• Recirculation loops are permitted.
• Dynamic rating of pressure relief valves can be modeled using the DIERS methodology.
The batch reactor mass balance starts with the generic dynamic mass balance relation:
Rate of accumulation = rate in – rate out + rate of formation
where
rate of formation = reaction rate – rate of evaporation/condensation
For CC-ReACS, the individual component balances are expressed:
22
CC-DYNAMICS Version 5.5 User’s Guide
dC i dV
V⋅ = ∑ Fin, j ⋅ C j,i − Fout ⋅ Ci + ∑ rn,i ⋅ V − Ci
dt dt
where
V = Reaction mass volume
Ci = Concentration of component i
t = Time
Fin,j = The flow rate of feed j
Cj,i = The concentration of component i in feed j
Fout = The flow rate of the liquid draw stream
rn,i = The rate of reaction n in component i
CC-ReACS provides two standard forms for the rate expression. In addition, the user may define his/her
own reaction rate expression or algorithm.
The standard rate expressions are:
23
User’s Guide CC-DYNAMICS Version 5.5
Arrhenius Equation
For a single reaction, the Arrhenius equation looks like this:
( )
r = A ⋅ e −E/(RT) ⋅ ∏ Ciai
where
r = The rate of the reaction in moles per volume-time
A = The frequency factor
E = The activation energy
R = The gas law constant
T = The reaction temperature
Π = The multiplication operator
Ci = The concentration of species i
ai = The order of the reaction for species I
Langmuir-Hinshelwood Equation
The Langmuir-Hinshelwood equation is the Arrhenius equation multiplied by an “adsorption resistance”
factor, F. The Langmuir-Hinshelwood equation is intended to model the impact of mass transfer
resistance associated with using a solid catalyst. Since this modification requires a lot of data to
determine the adsorption terms, it is not frequently used. Note that if β=0, F=1 and the reaction rate
becomes the simple Arrhenius form.
−β
F = 1+ ∑ φ i ⋅ e − E i / (RT ) ⋅ C ib i
therefore
( )( )
r = A ⋅ e −E/ (RT ) ⋅ ∏ Cia i ⋅ 1+ ∑ φ i ⋅ e −E i / (RT ) ⋅ Cib i
−β
where
φi = The adsorption frequency factor for species i
bi = The adsorption exponential factor for species i
β = The power factor for reaction adsorption sites
24
CC-DYNAMICS Version 5.5 User’s Guide
Π = Multiplication operator
This is the Langmuir-Hinshelwood form. When φk,j, bk,j, and/or βj are zero, this equation reduces to the
Arrhenius form.
The following should be noted about the standard reaction rate models:
1. Reactions can take place only in the liquid phase.
2. Where two liquid phases are present, they are treated as a single liquid phase when computing
reaction rates. The concentration terms are calculated as the overall concentrations of the
combined liquid phases. In addition, the amount of any given species, which is available for
consumption, is the total amount of that species present in the combined liquid phases.
25
User’s Guide CC-DYNAMICS Version 5.5
3. Unless otherwise specified, the order of reaction j in species i is assumed to be equal to the
stoichiometric coefficient of species i in reaction j.
4. Only reactant concentration terms can participate in the rate expression. Where this is
inconvenient, specify the non-reactant as a reactant with a stoichiometric coefficient less than the
calculation mass balance tolerance. Then specify the order at the desired value. For example, if A
goes to B in the presence of homogeneous catalyst, C, and the rate data indicates that the
concentration of C linearly influences the reaction rate, then:
a. Specify the stoichiometry:
A + 10 −7 ⋅ C → B
r = A ⋅ e −E/RT ⋅ [A ] 1 [C] 1
User Added Rate Expressions:
If the user has rate expressions that are not in the Arrhenius form, he/she can also enter them into CC-
ReACS. The user rate expression setting allows the user to enter a reaction expression, which is
interpreted by Microsoft Excel. The method for defining a user added rate expression or algorithm is
provided in Appendix II of this user’s guide.
26
CC-DYNAMICS Version 5.5 User’s Guide
+ Heat of reaction
- Latent heat of evaporation/condensation
- Heat transferred to/from the jackets and coils
- Heat transferred to and from the atmosphere
These terms are described individually below:
1. Inlet and outlet stream enthalpies
The feed enthalpies are inputs to the reactor model and are determined by the selected
thermodynamic routines and the UnitOp the feed came from (if any). The reaction simulation
determines outlet enthalpies.
2. Heat of reaction
Unless specified by the user, CC-ReACS calculates the heat of reaction from the thermochemical
properties of the reactants and products:
where
∑ (∆ H f of products ) T,P is the sum of the heats of formation for the reaction products at the
system conditions.
and
∑ ( ∆ H f of reactants ) T,P is the sum of the heats of formation for the reaction reactants at
the conditions.
For liquid components:
Tb T
∆ H f (T ) = ∆ H f, ig (25 ) + ∫25 Cp,g dT − ∆ Hv (Tb )− ∫Tb Cp,l dT
where
Hf (T) = The heat of formation at the system temperature
Hf,ig (25) = The standard (ideal gas at 25• C) heat of formation of the component
Tb = Boiling point at component
Cp,g = The ideal gas heat capacity of the component
27
User’s Guide CC-DYNAMICS Version 5.5
3. Thermal modes
The batch reactor model has the following thermal simulation modes:
• Isothermal – the required heat duty is calculated
• Adiabatic – heat transfer to and from the reaction mass is assumed to be zero
• Adiabatic with specified heat duty – the heat duty to and from the reaction mass is assumed to
be equal to a constant user specified value
• Specify time/temp profile – a heat duty is calculated to conform to a user-specified temperature
profile
• Specify jackets/coils – heat transfer to and from the reaction mass is calculated using heat
transfer methods
• Specify time/heat duty profile- – heat transfer to and from the reaction mass is taken from a
user-specified schedule
• Specify vapor rate and P, calc duty – the heat duty is calculated based on the users selection of
vapor product rate and pressure.
4. Heat loss to the ambient
If the user specifies the overall heat transfer coefficient, U; the available heat transfer area, A; and
the ambient temperature, Ta, the program will calculate a heat gain/loss using the expression:
Q = U ⋅ A ⋅ (T – Ta)
Where T is the reaction mass temperature and Q is the heat transferred.
5. Heat transfer to and from jackets and coils
Heat transferred to/from the reaction mass from/to jackets and coils is computed using heat transfer
methods whenever the “Specify jackets/coils” thermal mode is selected. Standard industry heat
transfer methods are used. These methods are described in a later section of this guide.
The following points should also be noted regarding the reactor side heat balance:
1. If the relief device is included in the simulation, it will influence the heat balance like so:
• The DIERS methodology affects the amount and composition of the material exiting the vapor
vent. The enthalpy of this material is included in the heat balance.
• A relief simulation can involve the calculation of an emergency heat load such as that created
by a fire. This emergency heat load is included in the heat balance and is in addition to any
other heat duty specified or calculated elsewhere.
28
CC-DYNAMICS Version 5.5 User’s Guide
2. The program does not calculate required agitator horsepower. However, if the user specifies the
agitator horsepower, it will be included in the heat balance.
3. In order to activate the program’s heat transfer calculations, it is necessary to select the “Specify
jackets/coils” thermal mode. Selection of this mode is required if a PID control system is to be used
on the reactor jacket. However, it is not necessary to set up a PID control system if this mode is
selected. It is possible to specify a fixed or scheduled utility flow to a jacket or coil.
Figure 2.1 illustrates the local heat transfer model used by CC-ReACS.
29
User’s Guide CC-DYNAMICS Version 5.5
Figure 2.1
where
U = The overall heat transfer coefficient
hp = The process (reaction) side heat transfer (film) coefficient
fp = The process side fouling factor
Xw = The reactor vessel wall thickness
ƒu = The utility side fouling factor
kw = The thermal conductivity of the reactor wall
30
CC-DYNAMICS Version 5.5 User’s Guide
where
Q = The heat transferred
U = The overall heat transfer coefficient
A = The heat transfer area
LMTD = The log means temperature difference between the process and utility sides
The vessel wall thickness, thermal conductivity and the fouling factors are specified by the user.
The reaction mass temperature, Tr, and the jacket/coil temperature, Tj, are determined by the heat
balances. Since the heat balances on the reaction and utility sides are linked by the heat transfer
calculation, the determination of Tr and Tj is coupled.
This leaves the following variables requiring explanation:
• The process side heat transfer coefficient, hp
• The utility side heat transfer coefficient, hu
• The heat transfer area
The process (reaction) side heat transfer coefficient
CC-ReACS will calculate a process side heat transfer coefficient at two locations; the reactor vessel wall,
and the outside surface of an internal coil that is immersed in the liquid reaction mass. The Seader-Tate
equation is used in both situations. This equation is:
c
µ
Nu = f ⋅ Re a ⋅ Pr b ⋅ w
µ
where
Nu = Nusselt number
Re = Reynolds number
Pr = Prandtl number
µ = Bulk fluid viscosity
µw = Viscosity of the fluid at the reactor wall temperature
The coefficients f, a, b, c are dependent on which agitator is used. The user must supply them if an
agitator other than the default agitator is to be modeled. A table of acceptable values for common
agitators is provided in the appendix.
Utility side heat transfer coefficients
Film coefficients for spiral baffled jackets, dimpled jackets, and half pipes are calculated using the
following methods:
31
User’s Guide CC-DYNAMICS Version 5.5
0.14
µ De
Re < 10,000; Nu = 0.027 ⋅ Re 0.2 + Pr 0.33 ⋅
1+ 0.35
µw Dc
0.14
0.75
0.03 Re ann ⋅Pr µ
Nu =
1.74 (Pr − 1) µ w
1+
Re 0.125
ann
where
Nu = Nusselt number
Re = Reynolds number
Pr = Prandtl number
µ = Viscosity
De = Equivalent diameter
w = Reactor wall
ann = Annulus of the jacket
The characteristic dimension in the Reynold’s and Nusselt numbers is the equivalent length, De. The
characteristic velocity in the Reynolds number is Uh. These are calculated below:
0.5
8
De = ⋅δ
3
( )
Uh = Uann ⋅ Uo 1/2 + Ubuoy
32
CC-DYNAMICS Version 5.5 User’s Guide
where
Mmed
Uo =
⋅( )
q π d2 / 4
0
The following applies for radial inlets:
Mmed
Uann =
q π dRo δ
Both free and forced convection occurs. The free convection is described by a “buoyancy rate” Ubuoy:
(
Ubuoy = 0.5 2 g hann β ∆ ϑ 1/2 )
If the inlets are tangential, the following equation applies
Mmed
Uann =
q hann δ
If the inlets are tangential, the only means of allowing for the buoyancy rate Ubuoy is vector addition. For
this reason, Ubuoy was ignored by Lehrer in the range of Reynolds numbers investigated.
where
Ubuoy = 0
For jackets with agitating nozzles the program uses the Pfaudler methods for heat transfer. These
methods are too lengthy for proper description here and the user is referred to the Pfaudler heat transfer
manual.
For internal coils the Seader-Tate equation is used to calculate the heat transfer coefficient.
Determination of the heat transfer area
Each jacket or coil has a heat transfer area dependant upon the level of fill in the reactor. The jacket
may cover the base and walls of the vessel, the base only or the wall only. The area for heat transfer is
calculated using:
(V − Vmin ) ⋅ (A
A= max − A min ) + A min
Vmax − Vmin
Where the maximum and minimum heat transfer areas Amax and Amin and the corresponding volumes
Vmax and Vmin are specified. If the level of fill exceeds Vmax then the area is limited to Amax. If the level of
fill falls below Vmin as in a vessel with a dished base, the area is linearized between Amin and zero.
33
User’s Guide CC-DYNAMICS Version 5.5
V
For V < Vmin A = ⋅ A min
Vmin
The variation of heat transfer area with level of fill is illustrated below.
Reactor capacity
Amax at Vmax
A at Vr
Amin at Vmin
The capacity of a jacket should be entered as the total volume of the jacket including any recirculation
loop. The model assumes the jacket is well mixed. For a recirculating system, the recirculation rate is
assumed to be sufficiently fast for the contents of the recirculation loop to be the same temperature as
the contents of the jacket.
In the default condition, CC-ReACS calculates the pressure in the reactor. It does this by including a
constant volume flash in the equation set. The program holds the reactor volume constant and varies
the reactor pressure until the summation of the vapor volume and the liquid volume equal the reactor
volume. The user may turn this feature off by specifying the reactor pressure. In this case, the
summation of the vapor and liquid volumes will not necessarily equal the reactor volume, unless the user
specifies vapor draw to maintain pressure.
The following points should be noted regarding the pressure calculation:
1. If the pressure is to be calculated, the flowrate of the vapor vent or outlet stream (if present) must be
specified. If not, the problem is under specified. However, this specification can be made explicitly
by the user by scheduling the vapor flowrate, or it can be made implicitly using a PID control system.
An example of the latter would be a pressure control system where the vapor flowrate is adjusted to
maintain a described reactor pressure.
2. Frequently, the initial charge specifications will produce volumes that do not match the vessel
volume. If the pressure is to be calculated, this can produce unwanted results unless certain
conventions are adopted to manage this situation. In CC-ReACS, the following conventions are
adopted:
34
CC-DYNAMICS Version 5.5 User’s Guide
a. If the liquid present exceeds the reactor capacity, an error message is issued and the
simulation will not proceed.
b. If the initial charge is subcooled, then the program will do an adiabatic flash to reset the
temperature and pressure to values which fill the vessel. A warning message will be issued.
c. If the initial charge is two-phase at the specified temperature and pressure, and the sum of the
vapor and liquid volumes is not equal to the reactor volume, an error message will be issued. If
the user chooses to go ahead with the simulation, then the program proceeds as follows:
• The vapor and liquid amounts and compositions are determined.
• The available vapor space is determined by subtracting the liquid volume from the reactor
volume.
AVS = RV - LV
where
AVS = Available vapor space
RV = Reactor volume
LV = Liquid volume
• The “excess” vapor is calculated below:
EV = VV – AVS
where
EV = Excess vapor
VV = Vapor volume of the initial charge
The excess vapor is therefore negative if the initial charge does not fill the reactor vessel.
• The excess vapor is removed from the initial charge so that the vapor volume, VV, exactly
equals the available vapor space, AVS. If the excess volume is negative, this means
adding enough vapor (of the same composition as the initial vapor) to fill the available
vapor space.
35
User’s Guide CC-DYNAMICS Version 5.5
RELIEF CALCULATIONS
The CHEMCAD Relief device model is explained in detail in the on-line help system. No effort is made
to repeat that information here. The following points, however, are specific to CC-ReACS and should be
noted.
1. Only the rating calculations can be performed in CC-ReACS dynamically. The size of the relief
valve and/or rupture disk must be specified. CC-ReACS will then calculate the amount, composition
and vapor quality of the material which passes through the vent. This material is then removed from
the heat and material balance. The relief device may be sized based on the CHEMCAD Relief
Device Sizing routine, see the on-line help system for details.
2. The vent inlet pressure is determined dynamically based on vessel contents and heat input. The
valve (disk) backpressure may be specified by the user and is fixed throughout the simulation, or
calculated using a nodes and pipe segments to define the flare header system.
Input for the Batch Reactor requires completion of the following dialog boxes:
• The Initial Charge dialog box
• The General Information dialog box
• The Rate Equation Units dialog box
• The Reaction Kinetics dialog box
• The T/Q Profile dialog box
• The Reactor Specifications dialog box
• The External Feed Schedule dialog box
• The Product Draw Schedule dialog box
• The Relief Device dialog box
• The Set Screen Information dialog box
It is not necessary (or even possible) that all of these dialog boxes be completed for every problem.
Obviously, you do not need to complete the Product draw dialog box if you are simulating a strictly
batch process. The bulk of the input is provided through the first four dialog boxes listed above. The
others are used as needed. CC-ReACS will not permit access to those dialog boxes that are not
relevant to the current simulation. The programs “access decisions” are made based upon specifications
made in the General Information dialog box.
36
CC-DYNAMICS Version 5.5 User’s Guide
All of the above listed items are accessed through the Batch Reactor Menu, which appears whenever
you double-click on a batch reactor UnitOp on a flowsheet. To access a dialog box, you simply click on
the appropriate Batch Reactor Menu item. When the dialog box is closed, control will return to this
menu.
A field by field description of the input for each of these dialog boxes is provided below:
The Reactor Initial Charge dialog box has the same structure and format as a CHEMCAD stream
dialog box. Only the flow units are amounts instead of rates. This dialog box also follows the same input
conventions as a stream dialog box, therefore:
1. The composition must always be specified. If it is specified as component amounts, then the total
amount is determined by CC-ReACS as the sum of the component amounts. If the composition is
specified as component fractions (mole, mass, or volume), then the total amount must be user
specified.
2. If the specified component fractions do not sum to one the program will normalize them.
3. The user must specify any two of the initial charge’s Temperature, Pressure, and vapor fraction.
From this input the program will calculate the enthalpy of the initial charge.
4. A user specified vapor fraction of one (1.0) is taken to mean the dew point. A user specified vapor
fraction of zero (0.0) is taken to mean the bubble point.
5. Enthalpy cannot be user specified.
37
User’s Guide CC-DYNAMICS Version 5.5
Please refer to the CHEMCAD User’s Guide for a detailed description of how to complete stream dialog
boxes.
The Batch Reactor General Information dialog box has three pages, which appear below:
38
CC-DYNAMICS Version 5.5 User’s Guide
GENERAL INPUT
The batch reactor can accommodate any number of simultaneous reactions. For each of these
reactions, the stoichiometry and rate data must be given in the Reaction Kinetics dialog box.
Show plot during simulation:
You may turn the runtime plot on or off. If the runtime plot option is on, then the specific variable plotted
is specified on the Set Screen Information dialog box. Multiple runtime plots can be specified using
the Record Streams and the Record Unit Operations options on the Dynamics Menu.
39
User’s Guide CC-DYNAMICS Version 5.5
40
CC-DYNAMICS Version 5.5 User’s Guide
Mode 2: Adiabatic:
The batch reactor can also be adiabatic. For this option, CHEMCAD calculates the reaction
temperature for the batch reactor. As in the case of isothermal operation, the reactor control is not
relevant, and control and heat transfer calculations are not performed.
Mode 3: Specified heat duty:
This option is a special form of the adiabatic mode. It requires an entry for heat duty. As in modes
1 and 2, the reactor control system is not specified or used.
Mode 4: Specify time/temperature profile:
The user may fix the temperature of the reaction mass at each time step by specifying the
temperature profile, that is, the temperature as a function of time. A heat duty will be calculated at
each time step. The temperature profile is provided on the T/Q profile dialog box, which is accessed
from the “Batch Reactor Menu”. The input for the T/Q profile is described in detail below.
Mode 5: Specify jackets/coils:
Using this mode heat transfer calculations are made based upon the flow and conditions on the
jacket side (and/or coil side) and the reaction side of the reactor. Although it is not required that a
control system be employed when using this mode, if a control system is to be specified, this mode
(5) must be selected. This requires that the user input the specifications for the control system
calculations. This is done in other menus and equipment.
Mode 6: Specify time/heat duty profile:
This option is similar to Mode 4 above, except that the heat duty/unit time is specified and the
temperature at each time step is calculated. Control is assumed to be perfect. The heat duty profile
is specified on the “T/Q Profile” dialog box (see below).
Mode 7: Specify vapor rate and P/calculate heat:
The user may fix the pressure and a vapor draw schedule to have the program calculate the
required heat duty. A vapor outlet stream must be connected to the reactor for this heat mode. The
vapor draw scheduled may be specified in the Product Draw Schedule menu.
Reaction Temperature:
If mode 1 is selected, then a field will open for the specification of the reaction temperature.
Heat duty:
If mode 3 is selected, then a field will open for the specification of the heat duty. This is the amount of
heat to be added or subtracted to the reactions. Negative indicates cooling. Positive indicates heating.
Pressure:
If you want CC-ReACS to calculate the reactor pressure at each time step, leave this field blank. If you
do not want the program to calculate the reactor pressure at each time step (that is, you want to specify
a fixed pressure for the simulation), then enter the reactor operating pressure.
If pressure is specified:
• For a single liquid phase reactor, all the thermal calculations, such as holdup density, holdup
volume, enthalpy, etc., will be calculated, but no flash calculation will be performed. If holdup
volume is greater than the reactor volume, the program will give an error message and stop the
simulation.
41
User’s Guide CC-DYNAMICS Version 5.5
• For a two-phase reactor, the program will use the given pressure and temperature to do the
flash calculations. The program will not check the holdup volume in this situation.
• For adiabatic reactors, the same rules apply, except that the temperature must be determined
iteratively.
If pressure is not specified:
• The program will take the temperature and reactor volume and do a flash until the right
pressure is found. That is, the pressure at which the total volume is equal to the volume of
reactor.
• If the user chooses a liquid phase reactor mode, the thermal calculations will not be pressure
sensitive. In this situation, the program will use the bubble point pressure in all calculations.
The program checks the holdup volume, gives error messages and stops the simulation if it is
greater than reactor volume.
SEMI-BATCH INPUT
CONVERGENCE INPUT
Integration Method:
The program offers two methods for integrating the reaction equations:
42
CC-DYNAMICS Version 5.5 User’s Guide
• Semi-implicit RK4 method: This is the fourth order, semi-implicit Runge-Kutta method. This
method is the more rigorous of the two methods, but it is slower computationally. For stiff
systems, that is systems where some variables move significantly faster than other variables, it
is necessary to use this method in order to get an accurate answer. Since most chemical
processes are stiff, this is the default.
• Runge-Kutta 4: This is the fourth order Runge-Kutta method. It is an explicit method and is
therefore not suitable for stiff systems. If you have a system where all reactions proceed
slowly, this method can save you significant computation time.
INTEGRATION PARAMETERS…
Step size:
This is the amount of simulated time between integrations. Since CC-REACS uses some form of the
Runge-Kutta method for all integrations, this step size is a starting point. It defines the largest step size
which can be used for integration. Input is required.
Tolerance:
This is the tolerance to be used by the Runge-Kutta method(s) for integration. This input is optional as
the program has a default.
CALCULATED RESULTS
Calculated results for important variables are summarized. Detailed data and plots of variables vs. time
may be prepared from the Results or Plot menus in CC-ReACS.
Reactor Temperature:
Reactor Temperature at the last calculated time step is displayed.
Reactor Pressure:
Reactor pressure at the last calculated time step is displayed.
Wall Temperature:
Reactor wall temperature at the last calculated time step is displayed.
Heat Rate:
The heat duty of the reactor at the last calculated time step. Negative represents heat removed, and
positive represents heat added.
Reaction heat rate:
The heat of reaction at the last calculated time step.
Liquid Level:
Liquid level in the reactor at the last calculated time step is displayed.
Overall Heat:
The overall heat transferred from the reactor is displayed. Negative represents heat removed, and
positive represents heat added.
Overall heat of reactions:
The cumulative heat of reaction for the reactor.
43
User’s Guide CC-DYNAMICS Version 5.5
The purpose of the Rate Equation Units is to permit the user to specify different engineering units for
the rate equations that are being used in the flowsheet globally. This makes entry of Arrhenius and
Langmuir-Hinshelwood parameters easier. The entry fields are:
Stoichiometrics/Equation Basis:
This option is used to specify whether the stoichiometry and rate equations have a mole or mass basis.
The available options are:
• Use mole basis for stoichiometry and rate equation.
Default mode
• Use mass basis for stoichiometry and rate equation.
This option is useful for biological reactions (stoichiometry becomes mass based), which are
often mass based. It is important to note that with the mass basis option, stoichiometry
becomes mass based.
Time units for rate equations:
0 hours
1 minutes
2 seconds
Volume units:
Volume units are used to specify concentration and reactor size. The volume units may be independent
of global volume units. Options are:
0 cubic feet
1 cubic meters
2 liters
3 cubic centimeters (cc)
Activation Energy and Heat of Reaction Units:
Activation energy units may be selected independently of global enthalpy units. Allowable options are:
0 Btu
1 kBtu
2 MMBtu
3 Joules
4 kJoules
5 MJoules
6 Cal
44
CC-DYNAMICS Version 5.5 User’s Guide
7 kCal
8 MCal
The energy units are based on mole units selected below.
Reference reaction temperature for heat of reaction:
This is the reference temperature for the heats of reaction. This value is given in the same temperature
0 0
units as are being used globally. If this field is left blank, a value of 77 F (25 C) is assumed.
This is a “reaction” dialog box and it permits the user to define the stoichiometry and the kinetic
relationship for a reaction. Simply fill in the blanks. The following rules apply:
1. One of the dialog boxes must be completed for each reaction. CC-ReACS knows how many
reactions are present by reading the “No. Reaction” field from the batch reactor General
Information dialog box.
2. CC-ReACS will display one Reaction Kinetics dialog box for each reaction specified in the
Number of Reactions field on the General Information dialog box. The user has three options to
edit reactions utilizing the option buttons at the bottom of the screen:
Edit next reaction: This is default option. Pressing OK when this option is selected will open
the reaction kinetics dialog box of the next reaction.
45
User’s Guide CC-DYNAMICS Version 5.5
Edit specified rxn: Pressing OK when this option is selected and a reaction number is input
will open the reaction kinetics dialog box of the specified reaction. This option allows scrolling
forward and backwards as well.
Exit Reactions: Pressing OK when this option is selected will stop the kinetics specification
process. The main batch reactor menu will appear.
3. If a standard rate equation is being used, then the program will return to the Batch Reactor Menu
when the user selects the Exit reactions option or after the last reaction dialog box is completed. If
a user defined rate expression is to be used, the program will go to the User Rate Expression
dialog box after the last reaction dialog box is closed or after selecting the Exit reactions option.
After the User Rate Expression dialog box is closed, the program will return to the Batch Reactor
Menu.
The total rate of reaction for a single component in a simultaneous reaction can be calculated using one
of the "standard" rate equations (Arrhenius or Langmuir-Hinshelwood) or it can be calculated using a
user defined rate expression. The form of the Arrhenius and the Langmuir-Hinshelwood equations are
described below. Use of the user defined rate equation facility is described in the appendices.
The Arrhenius / Langmuir-Hinshelwood equations:
−β j
nrx
a
nj nj
−E /(RT) −E /(RT) bk, j
∑
ri = Νi, j ⋅ Α j ⋅ e j
⋅ ∏ Ck k,j ⋅ 1+ ∑ φk, j ⋅ e k,j
k =1 k =1
⋅ Ck
j =1
Note: Most users will not have a need for the adsorption terms contained in the
second brackets. Leaving out such data, the rate expression reverts to the
traditional stoichiometric reactant-concentration dependent form with
Arrhenius temperature dependence.
where
ri = Rate of formation for component i, mole/volume-time
i = Subscript for component I
k = Subscript for reactant k
j = Subscript for reaction j
Ni,j = Stoichiometric coefficient for component / in reaction j
Aj = Frequency factor in reaction j
Ej = Activation energy in reaction j
R = Universal gas constant
T = Absolute temperature
Ck = Concentration of reactant k, mole/volume or the partial pressure of reactant k
ak,j = Exponential factor for reactant k in reaction j (Exp. reactor)
n = Number or reactants
nrx = Number or reaction
46
CC-DYNAMICS Version 5.5 User’s Guide
The input fields for the Reaction Kinetics dialog box are described below:
Frequency factor: This is variable Aj in the above equation. This is sometimes called the rate constant
(for isothermal reactions). The units of Aj depend upon the reaction order (the exponential factor).
Activation energy: This is variable Ej in the above equation. It has units of energy/mole.
Beta factor: This is the adsorption exponent Bj in the above equation. It is dimensionless.
Heat of reaction: This is the heat of reaction at system temperature and pressure. The user may
specify the heat of reaction. If not, CC-ReACS will calculate it from the constituent heats of formation.
Whether input or calculated, a negative value indicates an exothermic reaction and a positive value
indicates an endothermic reaction.
FOR EACH COMPONENT PARTICIPATING IN THE REACTION SPECIFY:
Stoichiometric coefficient: This is the stoichiometric coefficient of this component. If this component is
a reactant, it should have a negative value. If a product, it should have a positive value.
Exponential factor: This is the component activity exponent term, akj, in the above equation. In other
words, this is the order of the reaction in this component. If left blank, then if this component is a
reactant, then the exponent; akj is set equal to the absolute value of the stoichiometric coefficient. If this
field is left blank and this component is not a reactant, the exponent, akj, is set equal to 0.0.
Adsorption factor: This is the Langmuir-Hinshelwood adsorption frequency factor, φkj, in the above rate
equation. If left blank, φkj is set equal to zero and no adsorption resistance for this component is included
in the rate expression.
Adsorption energy: This is the Langmuir-Hinshelwood adsorption activation energy, Ekj, used in the
above rate equation. If left blank then Ekj is set equal to 0.0.
Adsorption exponent: This is the Langmuir-Hinshelwood adsorption component exponent, bkj, in the
above rate equation. If left blank, bkj is set equal to 0.0.
Note: It should be noted at this point that if the user is going to specify his/her own rate expression,
when the user selects the Exit reactions option or the last Kinetic Data dialog box (there is one for
each reaction) is closed, then the User Rate Expressions dialog box will automatically open. This
procedure and how to specify user rate expressions is explained in Appendix II.
The purpose of the T/Q Profile dialog box is to enable the user to specify:
47
User’s Guide CC-DYNAMICS Version 5.5
1. A time/temperature profile if the "4 Specify time/temp. profile" thermal mode is selected on the
Batch Reactor General Information dialog box.
2. A time/heat duty profile if the "6 Specify time/heat duty profile" thermal mode is selected on the
Batch Reactor General Information dialog box.
These two dialog boxes are shown below:
The BREA Temperature Profile dialog box:
48
CC-DYNAMICS Version 5.5 User’s Guide
The purpose of the Reactor Specifications dialog box is to specify the geometry, properties for the
materials of construction, heat transfer parameters, and initial conditions for the reactor and any jackets
or coils which might be integral to it. The Reactor Specifications dialog box is flexible and dynamic in
its input collection. The number of pages will depend upon prior specifications such as the thermal mode
and the number of jackets and/or coils to be used. Page one of the dialog box, the “General” page, is
always displayed.
Reactor manufacturer:
The user may specify the reactor parameters or choose a commercial reactor from the CC-ReACS
reactor vessel library. To select from the library, the vessel manufacturer must first be selected.
Reactor type:
Select a reactor vessel from the displayed manufacturers list.
Reactor size:
For the selected reactor type, choose a commercially available size from the list displayed.
A list of reactor vessels contained in the library is given in Appendix III.
The fields for reactor volume, reactor diameter, wall thickness, wall density, wall cp, wall thermal
conductivity, base volume, and base area are automatically filled in if a vessel is selected from the
library. The input for and meaning of these fields is explained below.
Reactor volume:
Enter the total volume of the reactor vessel.
49
User’s Guide CC-DYNAMICS Version 5.5
Reactor diameter:
Enter the Reactor diameter. The reactor diameter is used in conjunction with the reactor volume to
calculate the following values:
• Reactor liquid level
• Heat transfer area
• Inside film heat transfer coefficient
Wall thickness:
Enter the thickness of the vessel wall. This value is used in determining the heat transfer resistance of
the wall and the thermal mass of the reactor vessel.
Wall density:
Enter the density of the reactor vessel wall material. This value is used in determining the thermal mass.
Wall Cp:
Enter the heat capacity of the reactor vessel material. This value is used in determining the thermal
mass of the reactor vessel.
Wall Thermal Conductivity:
Enter the thermal conductivity of the reactor vessel wall material. This value is used in determining the
heat transfer resistance of the reactor wall.
Wall volume
Enter the wall volume. This value is used in determining the heat transfer resistance of the wall and the
thermal mass of the reactor vessel.
# of jackets and coils: Enter the number of jackets and coils (sum of both). This specification will
cause the program to open one additional input tab for each jacket or coil.
Base volume:
The base volume is the volume of material in the base of the reactor, that is, below the straight side of
the reactor. This value is used in determining heat transfer and liquid levels.
Base Area:
Enter the area of the base of the reactor.
Other optional inputs are:
Initial wall temperature: Enter the initial vessel wall temperature if desired. The default is the initial
charge temperature.
Optional for semibatch – Holdup: Enter the holdup for semi-batch operations. If the liquid volume is
greater than this amount, then the excess will go out the bottom stream from the reactor.
50
CC-DYNAMICS Version 5.5 User’s Guide
Q = U⋅ A ⋅ ∆ T
1
U=
1 xw 1
+ fi + +f +
hi k w o ho
where
Q = Heat transfer
A = Heat transfer area
∆T = Temperature of the reaction mass minus bulk temperature of the jacket fluid
hi = The film heat transfer coefficient at the inside of the reactor wall
fi = The fouling resistance at the inside of the reactor wall
xw = Reactor wall thickness
kw = Reactor wall thermal conductivity
fo = The fouling resistance on the outside (jacket side) of the reactor wall
ho = The film heat transfer coefficient at the outside (jacket side) of the reactor wall
51
User’s Guide CC-DYNAMICS Version 5.5
hi may be specified by the user if desired, but in the default condition, it is calculated by the program
using the Seader-Tate equation. Xw and kw are always specified although kw has a default value of 0.3
0
Btu/hr-ft F (carbon steel).
Reactor /Jacket hi-j:
This is the reactor side film coefficient (hi above) for heat transferred from the reaction mass to a jacket
or outside coil fluid. If the user makes an entry here, the value entered will be used to calculate U and
CC-ReACS will not calculate hi-j. If this field is left blank, CC-ReACS will calculate hi-j.
Reactor /Coil hi-c:
This is the reactor side film coefficient (hi above) for heat transferred from the reaction mass to an inside
coil fluid. If the user makes an entry here, the value entered will be used to calculate U and CC-ReACS
will not calculate hi-c. If this field is left blank, CC-ReACS will calculate hi-c.
Reactor fouling (reactor side):
This value must be input by the user because the default fouling resistance is 0.
IF hi-j AND hi-c IS NOT INPUT, ENTER THESE FIELDS:
Impeller/Anchor agitator:
Identify general agitator type.
Impeller diameter:
If the values of hi-j and/or hi-c are to be calculated by the program, data on the impeller/agitator will be
required. The impeller diameter is used in determining the Reynolds number at the wall. This in turn is
used when calculating the film coefficient.
Impeller speed (Hz):
Enter the speed of the impeller. As explained above in “Impeller diameter” this is needed to calculate the
reactor side film coefficient.
Motor power:
Enter the motor power if known. This value is optional but will be included in the heat balance if
provided.
Min. volume impeller:/Min. volume anchor: If a reactor vessel is selected from the database, values
are displayed in these fields. These values however are not used in any calculations.
Ambient Heat Loss: Coefficients U and A.
If the user enters U_loss (overall heat transfer coefficient from the reactor to the atmosphere) and A_loss
(heat transfer area for the loss to the atmosphere) (below), then CC-ReACS will calculate a heat loss
from the reactor to the environment and include this in the heat balance.
Ambient temperature:
Enter the ambient temperature for the heat loss calculation (Q = U_loss ⋅ A_loss ⋅ ∆T). The default is
0
70 F.
Seider-Tate correlation: The Seider-Tate correlation is used to calculate the heat transfer film
coefficient at the reactor wall (in the case of jackets or external coils) or on the process side of an
internal coil. Coefficients a, b, c and f must be supplied for the calculation.
52
CC-DYNAMICS Version 5.5 User’s Guide
FOR JACKETS AND EXTERNAL COILS: The Seider-Tate equation for the reactor side film heat transfer
coefficient at the reactor wall is:
c
µ
Nu = f ⋅ Rera ⋅ Pr b ⋅
µw
a, b, c and f are a function of which agitator is used. (See above.) Therefore, to calculate hi-j, these
fields must have entries. The defaults values are, a = 0.66, b = 033, c = 0.14, and f = 0.36.
FOR INTERNAL COILS: The Seider-Tate equation for hi-c is exactly the same as for hi-j (See above,
but the parameters a, b, c, and f are different.) These parameters are a function of which impeller is
used.
The purpose of these pages is to allow the user to specify the relevant geometry and heat transfer
parameters for jackets and coils. Since a given vessel may have more than one jacket and/or coil, one
page will appear for each jacket or coil.
The Jacket/Coils page appears as below:
Jackets are assumed to be well mixed. A jacket may cover the base and walls of the vessel, or just a
part of the wall. An external coil is considered to be a type of jacket. Coils are modeled as a series of
well mixed sections in which liquid flows from the bottom upwards. Jackets and external coils are
attached to the external wall of the reactor. Internal coils are in direct contact with the reaction mass.
Each coil is modeled as a series of well mixed sections.
53
User’s Guide CC-DYNAMICS Version 5.5
Jacket/Coil type:
This drop-down dialog box is used to identify the Jacket/Coil type. The available choices are Internal
coil, Dimpled/Half Pipe/External coil, Unbaffled Jacket, or Jackets with agitating nozzles. This
specification tells CHEMCAD which heat transfer equations to use on both the reactor and service side.
Each Jacket/Coil type requires specific geometric information to be input by the user.
Internal Coil: Coil total volume, Coil height, Coil diameter and Coil tube
diameter.
Dimpled/Half Pipe/External coil: Jacket total volume, Jacket height, Flow area and Wetted
perimeter.
Unbaffled Jacket: Jacket total volume, Jacket height, Jacket annulus and Inlet
diameter.
Agitating Nozzle Jacket total volume, jacket height, Jacket annulus, circulating
nozzle diameter, number of inlet nozzles, nozzle type.
All jackets and external coils on the reactor have a common wall with the reactor and therefore share the
same film heat transfer coefficient inside the reactor. Internal coils are not in contact with the reactor
wall and individual heat transfer correlation may be specified for each internal coil.
Heat Transfer area:
Each jacket has a heat transfer area dependent upon the level of fill in the reactor. The jacket may cover
the base and walls of the vessel, the base only or the wall only. The user must specify the minimum and
maximum heat transfer areas and the minimum and maximum reactor volumes that correspond to these
areas for each Jacket/Coil specification.
The area for heat transfer is calculated using:
A=
(V − Vmin ) ⋅ (A − A )+ A
(Vmax − Vmin ) max min min
Where the maximum and minimum heat transfer areas Amax and Amin and the corresponding volumes
Vmax and Vmin are specified. If the level of fill exceeds Vmax then the area is limited to Amax. If the level of
fill falls below Vmin as in a vessel with a dished base, the area is linearized between Amin and zero.
V
for V < Vmin A = ⋅ A min
Vmin
54
CC-DYNAMICS Version 5.5 User’s Guide
If there is a feed to the reactor, as there is in semi-batch operation, then the feed rate and timing must be
either calculated by the control system, or scheduled by the user. The External Feed Schedule dialog
box is for the purpose of providing feed schedules. It will not open unless the presence of a feed stream
is indicated on the General Information dialog box. The composition and thermodynamic condition (as
well as an initial flowrate) must be entered in the external feed stream.
It is possible to have multiple feeds, so one feed schedule dialog box per feed will appear.
An alternative way of scheduling a reactor feed is to use a ramp controller.
55
User’s Guide CC-DYNAMICS Version 5.5
If a vapor or liquid stream is taken from the reactor, the user may want to schedule the flow through
these draw streams. If so, then the Product Draw Schedule data entry screen must be completed. It is
shown below and operates exactly the same way as the “External Feed Schedule” data entry screen
described above.
56
CC-DYNAMICS Version 5.5 User’s Guide
The Batch Reactor UnitOp enables the user to schedule certain variables. By scheduling a variable,
we mean that even though the variable is non-constant, we are going to fix its value at each point in
time. A typical example would be a reactor feed, which is shut off three hours into the batch run.
Variables may be scheduled as stepped (constant over a specified period of time) or as ramped (varying
linearly over a specified period of time).
The following variables may be scheduled from within the batch reactor UnitOp:
1. Reactor operating temperature
2. Reactor heat duty
3. Reactor feeds
4. Reactor liquid draws
5. Reactor vapor draws
Since the input procedure for all of these is similar, they are all described together even though they
appear in different orders on the Batch Reactor Menu. First a general description of the CHEMCAD
scheduling conventions is given, then input information specific to each variable is discussed.
1. The Schedule Parameters dialog boxes have a Flow rate units list that enables the user to
specify the units of a feed or draw stream.
57
User’s Guide CC-DYNAMICS Version 5.5
The available options are mole, mass, volume, maintain holdup (for liquid draws only) and draw to
keep pressure constant (for vapor draws only). The engineering units used are the same as the
global flowsheet units.
2. The Schedule/Profile dialog boxes each have a list of “time” fields and “variable”. The units for
the time and the variable will be consistent with the global engineering units and are displayed on
this form.
The scheduling conventions used by the Schedule/Profile dialog box are as follows:
a. The variable value is zero until the time of the first point entered on the schedule.
b. Between schedule points a linear interpolation of the variable is always performed.
c. Therefore, if the following points are entered on a schedule;
Time, hr. Variable Value
1 100
3 50
Then at time equals two hours, the variable equals 75.
Likewise, if the following points are entered on a schedule;
Time, hr. Variable Value
1 100
3 100
3 50
Then, at time equals 2 hours, the variable value is 100. In addition, from time equals more than
3 hours to the end of the simulated batch run, the variable value will be 50. With 3 hours, the
variable value is 100.
58
CC-DYNAMICS Version 5.5 User’s Guide
59
User’s Guide CC-DYNAMICS Version 5.5
• It is not necessary to schedule a vapor draw. If the reactor vessel pressure is fixed by the user,
then the Draw Rate Units option on the Vapor Draw Schedule Parameters dialog box must
be set to Draw to keep P constant. In this case, the pressure will be fixed and at each time
step and the program will flash the contents of the reactor to determine the amount of vapor
and liquid present. Any vapor in excess of the calculated available vapor space will exit through
the vapor vent.
The Batch Reactor Relief dialog box enables the user to include the relief device calculations into the
batch reactor simulation. If this dialog box is completed, the vent flow calculations will be performed
provided relief conditions occur.
The relief calculations are handled differently than are normal vapor product draws. This has the
following implications for the batch reactor simulation:
1. When the relief analysis is included in the simulation, the fluid entering the vapor vent may be all
vapor or it may be two-phase (vapor-liquid). The composition of the two phases are computed and
the resulting two-phase vent fluid is subtracted from the material in the reactor. The impact of this
vent loss is completely accounted for in the heat and material balance.
2. In CC-ReACS, the relief device is in a rating mode (the device may be sized using CHEMCAD, see
the CHEMCAD help system documentation for details). This means the relief device must be fully
specified. During the simulation, the amount of fluid which will pass through the vent under the
prevailing conditions will be computed.
3. No fluid will exit through the vent unless vapor is generated. This requires that the Reaction
Mixture phase option on the General Information dialog box must be set to VL two phase,
liquid phase reaction.
60
CC-DYNAMICS Version 5.5 User’s Guide
4. Since:
a. The vent restricts the amount of material which can exit the vessel; and
b. Vapor may be generated continuously; and
c. The conditions in the reactor may be changing drastically during the simulation; and
d. The volume of vapor generated may not equal the volume of fluid exiting the vessel.
The pressure in the reactor must be variable. In order to permit this in CC-ReACS, the Pressure option
on the General Information dialog box must be left blank.
The relief device methods and required input are described elsewhere in this manual and no attempt is
made to reproduce that explanation here.
The user may select which plots he/she wants to be displayed during the simulation. For instance, the
reactor bulk temperature can be plotted on a function of time. These "runtime plots" can be selected at
two levels: (1.) from within a unit operation dialog box; or, (2.) from the Dynamics menu. Multiple runtime
plots can be displayed during the simulation, but only one per unit operation can be selected from a
UnitOp dialog box. The rest must be selected from the Dynamics menu. Up to six runtime plots can be
displayed at a time.
Clicking on the Set screen information button on the Batch Reactor Menu will display the Batch
Reactor Run Time Plot Options dialog box, like so:
This dialog box will allow you to specify the contents of one of the runtime plot windows displayed.
Time unit:
The time axis of a dynamic plot may be displayed in hours, minutes, or seconds. The user chooses
here.
61
User’s Guide CC-DYNAMICS Version 5.5
Plot Y scale:
The Ymin and Ymax fields will limit the range of the plot when they are entered.
Composition:
This window provides a list of component values to be plotted. These include mole fraction, mass
fraction, volume fraction, rate of formation, etc.
Enter the components to be plotted:
If a property was selected in the composition window above, then the user must identify which
components are to be displayed. These components are identified by position in the stream list. Up to
20 components are allowed. Each component may have its values exaggerated or dampened for
display by entering a scaling factor. The default is 1.0 (no exaggeration/dampening).
Other Plots:
The user may also plot any of the items listed on the right hand side of the screen by checking the box
next to the desired field. Variable plots may be combined as desired, but it is desirable that units be kept
consistent.
OVERVIEW
CC-DCOLUMN provides three different dynamic distillation models. Figure 1 provides a pictorial
summary of the dynamic columns available:
Figure 1
62
CC-DYNAMICS Version 5.5 User’s Guide
These models can be used in simple simulations without control system (assuming a perfect control
scheme) or in more complex studies with control systems.
The dynamic models of SCDS, TPLS and TOWR are extensions of their steady state models. Therefore
it is assumed the user is already familiar with the specification, topology, convergence of these models
common to CC-STEADY STATE. In this section we will discuss the dynamic features and specifications
of the SDCS, TPLS and TOWR models. The SCDS distillation UnitOp can also perform dynamic
calculations with mass transfer models.
After inputting or editing steady-state specifications, a dynamic column requires the completion of the
following dialog boxes:
! The General Information dialog box
! The Startup Parameters dialog box
! The Startup Charges dialog box
! The Column Holdups dialog box
! The Specs dialog box
! The Reflux control dialog box
! The Column Metal Heat Transfer dialog box
! The Record stages dialog box
! The Plot Options dialog box
It is not necessary that all of these dialog boxes be completed for every problem. Obviously you do not
need to complete the Startup Charge dialog box if you are simulating a process from steady-state
condition. CC-DCOLUMN will not permit access to those dialog boxes that are not relevant to the
current simulation. CC-DCOLUMN “access decisions” are made based upon specifications made in the
General Information dialog box.
All of the above listed items are accessed through the Dynamic Column Menu, which appears whenever
you finish editing steady-state specifications of SCDS, TPLS, TOWR and the dynamic mode of CC-
DCOLUMN is turned on. To access a dialog box, you simply click on the appropriate Dynamic Column
Menu item. When the dialog box is closed, you will return to this menu.
63
User’s Guide CC-DYNAMICS Version 5.5
A field description of the input for each of these dialog boxes is provided below:
The General Information dialog box is used to specify whether the simulation begins at startup or
steady state condition; if startup is to be wet or dry; and what type of holdup and pressure calculations
are to be performed.
64
CC-DYNAMICS Version 5.5 User’s Guide
If the simulation is to begin from startup conditions, then some initial liquid must be defined on the
Startup Charge dialog box. This is true for both dry and wet startup. In both cases, this liquid is the
initial charge in the bottom of the column. For wet startups the composition, temperature, and pressure
of the starting liquid on the trays is assumed to be the same as the charge in the bottom. The amounts
are determined from the holdups.
Note that during startup calculations, the column does not have a top or bottoms product.
Tray holdup calculation
These fields are used to define how vapor and liquid holdups are to be determined during the simulation.
Vapor holdups can only be calculated calculation if variable holdup is selected for the liquid phase. The
default is to ignore the holdups in both phases.
Liquid holdup can be constant, variable, or ignored (assumed to be zero). Variable holdup may be
ignored or calculated.
Constant Liquid Holdup
The user must specify the amounts of the holdups if constant holdup is selected. This is done
on the Column Holdups dialog box. These amounts can be specified in mass, mole, or volume
units and can be different on every stage if desired.
Variable Liquid Holdup
The program calculates variable holdups. This calculation is a function of tray (or packing) type
and geometry. Therefore, this information must be specified for the calculation to proceed.
These specifications are made under the Column Holdups option of the Dynamic Column
menu.
Vapor Holdups
Vapor holdups can be included in the calculation (if variable liquid holdups was selected) or
ignored (assumed to be zero). If they are included, they are always assumed to be constant
volume. The volume is determined from the column geometry.
Pressure Calculation
The column pressure can be fixed by the user or calculated by the program. If it is to be calculated by
the program, then variable liquid holdups must be selected above, and the column geometry must be
specified. Column geometry is specified using the Column Holdups option of the Dynamic Column
Menu.
The pressure calculation matches the fluid volumes to the column geometry and includes the tray (or
packing) pressure drop. The program calculates tray and packing pressure drops.
Display plot during simulation
To plot results of the simulation on the screen during the simulation, place a check mark in this box. The
data to be displayed is chosen in the Plot Options dialog.
Record frequency
This is the number of time steps between saving of the results. If the simulation integration time step is
one minute and the record frequency is five, the results will be saved every five (simulated) minutes.
65
User’s Guide CC-DYNAMICS Version 5.5
The Startup Conditions dialog box is used to specify startup time and conditions. Obviously this dialog
box is used only when a startup is to be simulated.
The specifications made on this dialog box apply only to the startup period. All fields on this screen are
required.
Duration Time
Define the duration of the startup period here.
Reboiler heat duty
During the startup time, the reboiler duty will be fixed at the value provided in the Reboiler heat duty field.
If you want to vary this value during startup, you can use the RAMP Controller UnitOp to schedule it.
66
CC-DYNAMICS Version 5.5 User’s Guide
Accumulator Holdups
The user must also specify the initial and maximum condenser accumulator holdups during startup.
Accumulator holdup unit
Choose the base units for the condenser accumulator holdup specification. Options are mass
of holdup, moles of holdup, volume of holdup, or liquid level in the condenser accumulator.
Maximum and Initial holdup
Accumulator liquid will start at the Initial holdup value and rise to the Max accumulator holdup
value.
Between these two values there will be no reflux to the column. Once the maximum holdup
value has been reached, the reflux to the column is any amount in excess of the maximum
holdup. This is the total reflux simulation.
Pressure Calculation
Pressure during the startup period can be fixed or variable. Variable pressure is calculated by CC-
DCOLUMN and requires specification of the column geometry.
This specification is independent from whether the pressure is fixed or calculated during the simulation
(as per the General Information dialog). You may have the pressure calculated during the startup
portion of you simulation and fixed at a specified value for the remainder of the simulation. The reverse
is also possible. There is no restriction on the combination of methods for the startup pressure
calculation and the initial conditions pressure calculation.
STARTUP CHARGE
The column startup charge dialog has the same structure and format as a CC-STEADY STATE stream
dialog box. Only the flow units are amounts instead of rates. This dialog box also follows the same input
conventions as a stream dialog box, therefore:
1. The composition must always be specified. If it is specified as component amounts, then the total
amount is determined by CC-DCOLUMN as the sum of the component amounts. If the composition
is specified as component fractions (mole, mass, or volume), then the total amount must be user
specified.
2. If the specified component fractions do not sum to one CC-DCOLUMN will normalize them.
3. Two (but only two) of the thermodynamic properties, temperature, vapor pressure and pressure;
must be specified by the user. Any combination is acceptable. From these two (plus the
composition) the program will initialize the charge (i.e., calculate the third plus enthalpy).
4. A user specified vapor fraction of one (1.0) is taken to mean the dew point. A user specified vapor
fraction of zero (0.0) is taken to mean the bubble point.
5. Enthalpy cannot be user specified.
67
User’s Guide CC-DYNAMICS Version 5.5
Please refer to the CC-STEADY STATE User’s Guide for a detailed description of how to complete
stream dialog boxes.
The Column Holdups dialog box will be only available if the Constant liquid holdup or Variable liquid
hold up option was selected in the General Information dialog box. If one of these options was
selected, then the Column Holdups dialog box must be completed.
If variable liquid holdups are to be used, the column layout must be specified. This is done using a set of
dialog boxes constructed for this purpose. Exactly which dialog boxes appear depends on what device
is selected for mass transfer; i.e., valve trays, bubble cap trays, or sieve trays. These dialog boxes
appear when you close the Specify Column Holdup dialog box. Entries in the Specify Column Holdup
dialog box are unnecessary. Just close this dialog box. The program will prompt you through the rest of
the input.
Variable liquid holdup can only be used for simulating trayed columns. Packed columns are assumed to
have constant liquid holdup.
68
CC-DYNAMICS Version 5.5 User’s Guide
Stage holdup
Stage holdup is the total amount of liquid on each stage. The number of stages is specified by the user
on the column’s main specifications dialog. The total stage holdup is this number of stages times the
stage holdup value input here.
Reboiler holdup
Reboiler holdup is the amount of liquid in the bottom of the column plus the liquid in the reboiler plus the
liquid in the reboiler accumulator vessel (if any).
Specify a Holdup Profile
Stage holdups can be specified stage-by-stage if desired. To do this place a check mark in the Specify
a Holdup Profile field. When this dialog box is closed, the Stage Holdup dialog box will open. On this
dialog box specify the key stage numbers and holdup values. Holdups for omitted stages are
determined by linear interpolation between those stages provided.
Dead Time per stage (optional)
This option allows the user to directly specify additional stage dead time. The user specifies the duration
of the time delay which the stages experience.
The dynamic column specifications dialog box has two pages, which appear below:
69
User’s Guide CC-DYNAMICS Version 5.5
CONDENSER INPUT
70
CC-DYNAMICS Version 5.5 User’s Guide
Reflux specification
For constant condenser holdup, the program calculates reflux to maintain holdup.
For variable condenser holdup, the reflux rate may be either fixed or controlled. The user must either
specify a fixed reflux flowrate or set up a control system to adjust it dynamically.
A fixed reflux flowrate can be specified in mass, mole, or volume units. The selection is made from the
list in the Reflux specification field. The numerical value of the reflux flowrate is given in the Reflux
rate field.
Select by control valve to use controlled reflux. The reflux control valve and PID controller are then
specified in the Reflux Control dialog.
Liquid distillate specification
For constant condenser holdup, the liquid distillate is calculated according to the specifications for the
condenser operation (see above Condenser holdup option…).
For variable condenser holdup, the flow rate of liquid distillates must be either fixed or set by control
valve. That is, the user must either specify a fixed flowrate or use a control valve (and control system) to
adjust distillate flow dynamically.
A fixed distillate flowrate can be specified in mass, mole, or volume units. The selection is made from
the list in the Liquid distillate specification field. The numerical value of the reflux flowrate is given in the
Distillate rate field.
Distillate control is performed using an external control system. The control system is specified and
calculated outside the dynamic column UnitOp using the PID Controller and the Control Valve UnitOp
modules. The flowsheet ID number of the liquid distillate control valve must be entered in the Distillate
Control Valve ID Number field of the current dialog box. Note: the distillate control valve UnitOp can be
run without use of a PID Controller.
For a condenser with a UA specification (optional specification)
If a condenser control system is being used, the user has the option of simulating the condenser
operations using UA specifications and a utility control system. Those specifications are made in this set
of fields.
The utility stream inlet and outlet ID numbers and the utility stream control valve ID number must
be specified. The program uses these to determine the utility flowrate and properties.
The utility pressure drop specification is optional. If entered the utility outlet pressure will be set to its
inlet pressure minus this value.
The condenser U is the overall heat transfer coefficient. It must be specified by the user.
The condenser A is the heat transfer surface. It also must be specified by the user.
Optional level specifications
If variable condenser holdup is to used, these fields may be entered. Variable condenser holdup is
treated as if all the condenser liquid is kept in a vessel.
71
User’s Guide CC-DYNAMICS Version 5.5
These specifications only describe the vessel dimensions and liquid level. The level specifications are
only useful when used in conjunction with a level control system.
Orientation – The vessel may be horizontal or vertical. This specification will impact when the
accumulated condenser liquid exceeds its level specification.
Head type – Vessel heads can be ellipsoidal, hemispherical, bumped, or flat. This will affect when the
level specification is exceeded.
Radius/depth head ratio – The head ratio will determine the amount of liquid held by the vessel head.
This will influence the vessel liquid level. If this field is left blank, the program will use default values.
Diameter – This is the inside diameter of the vessel.
Cylinder length – This is the tangent to tangent length of the vessel.
Initial liquid level – This is the liquid level at the start of the simulation. This is from the bottom of the
head, for a vertical vessel.
REBOILER INPUT
Reboiler holdup can be variable even if tray holdup is constant.
If reboiler holdup is constant, then the reboiler is assumed to operate according the reboiler specification
from the steady state column specifications page. At each time step, bottoms flowrate (instantly)
recalculated to match the reboiler specification.
For example, if;
a. A bottoms purity specification is made on the Specifications page of the Distillation Column
(SCDS, TPLS, TOWR) dialog box, and
b. Constant reboiler holdup is specified on the Reboiler page of the Column Specifications
dialog box, then
During the dynamic simulation, the program will hold the bottoms purity constant at the value
specified in item a, above. The bottoms flowrate will be adjusted at each time step to maintain
this purity, and the constant holdup.
For Variable reboiler holdup, the specifications on this screen (reflux and distillate) will control the
reboiler. The steady state column specifications page reboiler spec will be ignored. For example: if the
user specifies a bottom purity in the steady state column and variable holdup for the reboiler…the purity
specification will be ignored.
Variable reboiler holdup is treated as if all the liquid is kept in a vessel. This is similar to reality, since the
bulk of the "reboiler accumulator" liquid is held in the bottom of the column vessel. The dimensions of
this vessel may be specified in the optional level specifications fields. For variable holdup, entering
the vessel geometry allows calculation of liquid level in the reboiler (based on holdup).
Bottoms rate specification
For variable reboiler holdup, the bottoms rate may be either fixed or controlled. The user must either
specify a fixed bottoms flowrate or set up a control system to adjust it dynamically.
72
CC-DYNAMICS Version 5.5 User’s Guide
A fixed bottoms flowrate can be specified in mass, mole, or volume units. The selection is made from
the list in the Bottoms rate specification field. The numerical value of the bottoms flowrate is given in
the Bottoms rate field.
Bottoms flowrate control is performed using an external control system. The control system is specified
and calculated outside the dynamic column using PID Controller and the Control Valve UnitOp modules.
The flowsheet ID number of the bottoms control valve must be entered in the Bottoms Control Valve ID #
field of the current dialog box. Note: the bottoms control valve UnitOp can be run without use of a PID
Controller.
For a reboiler with a UA specification
If a reboiler control system is being used, the user has the option of simulating the reboiler operations
using UA specifications and a utility control system. Those specifications are made in this set of fields.
The utility stream inlet and outlet ID numbers and the utility stream control valve ID number must
be specified. The program uses these to determine the utility flowrate and properties.
If a thermosyphon reboiler is to be simulated, the recirculation rate must be specified in the
Thermosyphon Recirculation Rate field.
The utility pressure drop specification is optional. If entered the utility outlet pressure will be set to its
inlet pressure minus this value.
The reboiler U is the overall heat transfer coefficient. It must be specified by the user.
The reboiler A is the heat transfer surface. It also must be specified by the user.
Optional level specifications
If variable reboiler holdup is to used, these fields must be entered. Variable reboiler holdup is treated as
if all the reboiler liquid is kept in a vessel.
These specifications only describe the vessel dimensions. The level specifications are only useful when
used in conjunction with a level control system.
Orientation – The vessel may be horizontal or vertical. This specification will impact when the
accumulated condenser liquid exceeds its level specification.
Head type – Vessel heads can be ellipsoidal, hemispherical, bumped, or flat. This will affect when the
level specification is exceeded.
Radius/depth head ratio – The head ratio will determine the amount of liquid held by the vessel head.
This will influence the vessel liquid level. If this field is left blank, the program will use default values.
Diameter – This is the inside diameter of the vessel.
Cylinder length – This is the tangent to tangent length of the vessel.
Initial liquid level – This is the liquid level at the start of the simulation. This is from the bottom of the
head, for a vertical vessel.
73
User’s Guide CC-DYNAMICS Version 5.5
This page is used to describe the Reflux control valve. The input is similar to that for the Control Valve
unit operation (CVAL) and is described below.
The control valve calculates the flowrate through the valve based on the input signal it receives from a
controller. The control valve can handle compressible and incompressible flow as well as critical and
sub-critical flow. The control valve calculates the following variables at each time step:
1. The valve position.
2. The flow through the valve.
The flowrate of the inlet and outlet streams will be reset to the control valve calculated flow.
The Reflux Control dialog box will be only available if following specifications were made:
1. The Variable Holdup option was selected on the Condenser Specifications page of the Dynamic
Column Specifications dialog box.
2. The By Control Valve option was selected for the Reflux specifications on the Condenser
Specifications page of the Dynamic Column Specifications dialog box.
The Reflux control dialog box has two pages, shown below:
74
CC-DYNAMICS Version 5.5 User’s Guide
VALVE INPUT
Valve type
Choose from either linear or equal percentage valves.
Linear valves relate the actual valve flow to the capacity valve flow by the following relation:
U 1
Actual Flow = 1 − ( Valve Capacity )
100 R
Equal percentage valves relate actual flow to capacity valve flow as follows:
U
− 1
Actual Flow = R 100 ( Valve Capacity )
Valve flow coefficient
This is the valve Cv. This field must be entered. If you do not know a good value for Cv, use the valve
sizing option under the Sizing menu. This option will calculate a good value for this field.
The definition of the flow coefficient is defined as follows:
0.5
SG f
C v = Q
∆Ps
75
User’s Guide CC-DYNAMICS Version 5.5
Rangeability
Rangeability is the ratio of the maximum to minimum controllable flow. This value is most important for
equal percentage valves because the relationship of R to U is non-linear. The default is 10.
Critical Flow Factor
The critical flow factor, Cf, is used to determine if the flow through the valve is above or below critical
velocity. If flow is subcritical, the valve position determines the flow. If critical flow conditions exist, then
flow is calculated as follows:
Non-compressible critical flow:
Cv ⋅ Cf
Q=
SG f
∆Ps
P
0.5
∆ Ps = P1 − 0.96 − 0.28 v
P
Pc v
Compressible Critical Flow:
834 ⋅ C f ⋅ P1
Q=
SG f ⋅ T
where
Q = Flow, US gpm for liquids; SCFH for gases
Cv = Valve flow coefficient
Cf = Critical flow factor
P1 = Inlet pressure in psia
Pc = Critical pressure of the fluid
SGf = Specific gravity of fluid; liquids referred to water at standard conditions; gases
referred to air at standard conditions
T = Flow temperature, R
76
CC-DYNAMICS Version 5.5 User’s Guide
Tv must be positive; therefore, the term T dU tends to slow down the valve response to the controller
v
dt
signal. The larger the value of this term, the more it slows down the response.
Valve Av
This is the Av term in the control valve position equation above. In the default condition, the controller
output is assumed to be between 4 and 20 milliamps and the term dU Since at the minimum
Tv = 0( zero)
dt
position, the valve is closed and u = 0 and at the maximum position, the valve is fully open and u = 1,
then,
0 = Av * 4 + Bv
1 = Av * 20 + Bv
therefore
Av = 0.0625
Bv = 0.25
These are the program default values for Av and Bv.
CALCULATED RESULTS
Calc. flow rate
The value displayed in this field is the current instantaneous flowrate through the valve.
Controller output
This is the value currently being received from the controller.
Steady state position
This is the steady state valve position determined from the steady state controller output, Po.
Controller output SS
This is the output signal from the controller at steady state. CC-DCOLUMN calculates this at the initial
valve position, assumed to be closed.
CONTROLLER INPUT
The PID Controller continuously measures a user-specified variable and, based upon the specified
setpoint for that variable, sends a controller output signal (in milliamps) to the control valve. The
controller can include proportional, derivative, and/or integral action in its signal computation. Cascade
controllers are permitted. The user may specify the control loop and controller limits if so desired. Also,
the controller time step may be set to a smaller value than the flowsheet integration time step.
77
User’s Guide CC-DYNAMICS Version 5.5
PB (proportional band)
The proportional band (PB) helps determine the speed of the controller output signal according to the
following equation:
Pout = P + I + D + P0
where
Pout = Controller output signal in milliamps
100
P= ⋅ error = proportional action
PB
100 1
I= ⋅ ⋅ (error ) dt = integral action
∫
PB Ti
100 d(error )
D = ⋅ Td ⋅ = derivative action
PB dt
and
P0 = Controller signal at steady state
PB = Proportional band
Ti = Integral time constant in minutes
Td = Derivative time constant in minutes
error = Current controller input - the controller input at steady state
78
CC-DYNAMICS Version 5.5 User’s Guide
The steady state output term allows the controller to function linearly on either side of the setpoint.
Setting Uss = 100% will fully open the control valve as soon as the controller is activated, whereas Uss =
0 starts the system with the valve closed and the controller will open the valve slowly in response to the
error signal.
Errors Definition
At the user’s option, the error may be defined in one of two ways:
1. Error = X - X set
2. Error = X set - X
where X = Controller input (in milliamps) at the current value of the measured variable.
X set = Controller input (in milliamps) at the setpoint value of the measured variable.
Equation (1) above should be used when the function being controlled is for cooling, pressure control, or
level control.
Equation (2) above should be used when the function being controlled is for heating or flowrate control.
These are guidelines. The general rule is as follows. The user should select the error function, which
ensures that the control variable will move toward the setpoint if an error exists. For instance, if the
service being controlled is steam flowrate to the jacket and the setpoint is the reactor main temperature,
the function "Error = X set - X" should be selected. This is true because when the reactor main
temperature is below the setpoint, the error will be positive and the steam valve will open. If in the same
situation, Error = X - X set was chosen, the error would be negative and the steam valve would close,
thus moving away from our target - not closer to it.
Setpoint
Enter the setpoint for the controller. This input is required, and the value must be non-zero.
SENSOR INFORMATION
Measured Variable
The measured variable is the variable we are trying to control. For instance, it we want to control the
mass flowrate of the reflux at 10,000 lbs. per hour, then the measured variable is mass flowrate and the
set point is 10,000 lbs. per hour.
The available options are:
! mass flow rate of the reflux
! molar flow rate of the reflux
! volume flow rate of the liquid reflux
! accumulator liquid level
! temperature of a specified tray
79
User’s Guide CC-DYNAMICS Version 5.5
Tray No.
If the measured variable is the temperature of a specified tray, then the tray (stage) number must be
entered in this field.
Controller/Sensor Function:
The functional relationship between the controller input and the output from the sensor is as follows:
Cin = Ac + Bc * X + Cc * X2
Cin = Controller input in milliamps
X = Value of the measured variable in the user specified engineering units
The coefficients Ac , Bc, Cc are calculated by the program using the function type and variables shown
below Controller/sensor function:
The user may specify whether the sensor function is linear or quadratic. The default is linear. The
quadratic form should be selected if the measured variable is flowrate. Otherwise, linear can be used.
The user must specify the minimum and maximum values of the measured variable.
The minimum and maximum sensor output values may be specified by the user if desired. The default
values are 4 and 20 milliamps, respectively.
Control limit
Indicate whether the controller limits specified are relative to the setpoint or to the limits. If no limits are
specified, "None" should be specified here.
Upper limit and Lower limit
The upper and lower limits put "dead bands" in the controller response. For instance, if the setpoint =
200°F and the lower limit is 195°F, the cooling water controller will shut the control valve off once the
temperature falls below 195°F.
CALCULATED RESULTS
Measured Variable
Integral:
If integral action is specified (I.e., if Ti is specified), the integral contribution to the controller output
function will be shown here.
Error
The last computed error is displayed here.
Controller output
This is the last output signal from the controller.
80
CC-DYNAMICS Version 5.5 User’s Guide
The Column Metal Heat Transfer dialog box will be only available if the include column metal heat
transfer option on the General Information dialog box was checked. All items of this dialog box must be
completed. The Column Metal Heat Transfer dialog box is shown below:
Metal Heat Capacity – Input the metal heat capacity in this field.
Average metal mass per stage – Input the average metal mass per stage.
Metal/Ambient Coefficient – Input the heat transfer coefficient between metal and the ambient.
Metal/Fluid Coefficient – Input the heat transfer coefficient between metal and the fluid.
Metal/Ambient transfer area – Input the heat transfer area per stage between metal and the fluid.
Initial metal temperature – Input the initial metal temperature.
81
User’s Guide CC-DYNAMICS Version 5.5
The stage number and the phase must be specified. CC-DCOLUMN numbers stages from the top down
with the condenser (if present) being stage number one and the reboiler (if present) being the last stage.
Only five stages can be saved (recorded).
A stage must be recorded before it can be plotted or printed out.
Recorded stage information includes:
! Composition.
! Flow rates.
! Temperature.
! Pressure.
82
CC-DYNAMICS Version 5.5 User’s Guide
Variable to be plotted
Define the variable to be plotted on the y-axis. Select one from the pull-down list.
Object to be plotted
Select one of the following. This field may not be needed if the variable specified above does not require
a location (e.g., Reflux Ratio).
! Distillate
! Bottom
! Stage
Stage Information
If a plot for one of the stages in the column is desired, specify the following:
! Stage No. – Enter the stage number for which the properties will be plotted.
! Phase – Indicate whether you are plotting data for the liquid or vapor phase.
! Time Unit / Frequency
Time Unit
Specify what time unit you want to use for the x-axis and the frequency you want plotted (hr, min, sec).
Plot Frequency
This is the number of time steps between plotting results. If the simulation integration time step is one
minute and the plot frequency is five, the results will be plotted every five (simulated) minutes.
Y-axis min/max values
CC-DCOLUMN allows tuning up the range for the plot of a recorded variable. Specify a minimum and
maximum for the y-axis of your plot
Components to be plotted
You may plot up to ten components by selecting them in this section. If the plot you select is any related
to flow or concentration (i.e. mole/mass/mass frac/ etc) you may want to select the component(s) to be
plotted. Select components from the pull-down list.
Control valves and PID controllers are present in both batch reactor and dynamic column simulations.
Because the PID Controller and the valve(s) it controls (Control Valve) always work together, they have
been described together in this one section. This makes the overall logic of the control system easier to
understand. If it were not for the need to model cascade control/ systems (where master controllers
control slave controllers), the PID Controller UnitOp and the Control Valve UnitOp could be combined
into a single module.
83
User’s Guide CC-DYNAMICS Version 5.5
The standard control system (not cascade) consists of three conceptual parts;
• Sensor- The sensor monitors or measures the set point variable and converts its measurement
into an electrical (milliamp) signal, which it transmits to the PID controller.
• PID Controller- The PID Controller uses this signal to compute an error. The error is the
difference between the set point milliamp equivalent and the electrical signal coming from the
sensor. The PID Controller then uses this error to generate a controller signal, also in
milliamps, which controls the valve.
• Control Valve- The control valve actuator uses the controller signal to open and close the valve.
The amount of the valve movement is a function of the amplitude of the PID control signal. As
the valve opens and closes, the flow rate through it changes.
Computationally, this system proceeds as follows:
1. Determine the actual value of the set point variable. For instance, determine the reactor
temperature in degrees F.
2. Calculate the sensor function (signal) in milliamps.
3. Calculate the error from the set point and the sensor signal.
4. Using the error compute the PID Controller output (signal) in milliamps.
5. Using the PID Controller signal, calculate the new valve position (present open or shut).
6. Based on the valve position, calculate the flow through the valve.
This is a how CC-DYNAMICS models a PID Control system.
This process must be repeated many times per time step to accurately represent the action of real
systems.
The details of these steps are described below.
DETERMINE THE VALUE OF THE MEASURED VARIABLE & COMPARE TO SET POINT
Measured variables are the quantities that you want to control. For instance, if you want to keep the
reactor pressure as close to a desired value as possible by adjusting its vapor draw rate, the reactor
pressure is your set point variable. The program calculates the current value of the measured variable,
and compares it to the set point.
You may use almost any parameter in the flowsheet to be a set point variable, it is specified in the PID
controller dialog box.
S = A + B ⋅ X + C ⋅ X2
84
CC-DYNAMICS Version 5.5 User’s Guide
where
S is the sensor output signal in milliamps. A, B, C are coefficients of the sensor function, x is the
current value of the measured (set point) variable in flowsheet engineering units.
The coefficients A, B, and C are calculated by the program from the maximum and minimum input and
output of the sensor. This calculation is made below:
1. The user must specify the following items:
a. Whether the sensor function is linear or quadratic. If linear is chosen, C will be set to 0 by the
program.
b. The maximum and minimum sensor output signal (in milliamps). Default values are 20 and 4
milliamps.
c. The values of the measured variable at the sensor maximum and minimum output signal.
Described in another way:
• The “maximum” value of the measured variable generates the maximum sensor output
signal. If the measured variable rises above this “maximum”, the sensor output remains at
the same upper boundary value.
• The “minimum” value of the measured variable generates the minimum sensor output
signal. If the measured variable falls below this “minimum”, the sensor output remains at the
same lower boundary value.
2. If the sensor function is to be linear, the coefficients A and B are determined from the specified
maximums and minimums.
3. If the sensor function is to be quadratic, then the coefficients B and C are computed from the
specified maximums and minimum.
where
Pout = Controller output signal in milliamps
100
P= ⋅ error = proportion al action
PB
100 1
I= ⋅ ⋅ (error ) dt = integral action
∫
PB Ti
100 d(error )
D = ⋅ Td ⋅ = derivative action
PB dt
85
User’s Guide CC-DYNAMICS Version 5.5
and
P0 = Controller signal at steady state
PB = Proportional band
Ti = Integral time constant in minutes
Td = Derivative time constant in minutes
error = Current controller input - the controller input at steady state
At the user’s option, the error may be defined in one of two ways:
error = X - Xset
or
Error = Xset - X
where
X = Controller input (in milliamps) at the current value of the measured variable.
Xset = Controller input (in milliamps) at the set point value of the measured variable.
Equation (1) above should be used when the function being controlled is for cooling, pressure control or
level control.
Equation (2) above should be used when the function being controlled is for heating or flow rate control.
These are merely guidelines. The user should select the error function which ensures that the control
variable will move toward the set point if an error exists. If the service being controlled is steam flow rate
to the jacket and the set point is the reactor temperature, the function Error = X set - X should be
selected. This is true because when the reactor temperature is below the set point, the error will be
positive and the steam valve will open. If in the same situation, Error = X - Xset was chosen, the error
would be negative and the steam valve would close, thus moving away from our target, not closer to it.
P0 is the value of the controller signal (in milliamps) at the steady state. If this field is left blank, P0 will be
calculated by the program based upon the initial state of the process.
The steady state output term allows the controller to function linearly on either side of the set point.
Setting P0 = 4 (the minimum signal) starts the system with the valve closed and the controller will open the
valve slowly in response to the error signal.
86
CC-DYNAMICS Version 5.5 User’s Guide
dU
Tv + U = A v ⋅P + B v
dt
where
Tv = The valve time constant (default = 0)
U = The valve position (in fractions)
P = The PID Controller output signal in milliamps
Av,Bv = The valve constants (Defaults are Av = 0.0625 and Bv = -0.25)
The valve position is related to the valve flow rate by the following equations:
87
User’s Guide CC-DYNAMICS Version 5.5
where
R = Rangeability (ratio of maximum to minimum controllable flow)
Cv = Valve flow coefficient
SGf = Specific gravity of flowing fluid
∆P = Pressure drop across the valve
U 1
⋅ C v ⋅ (∆P (P1 + P2 ) SG f )
0.5
Linear Valves : Flow = 3.22 ⋅ ⋅ 1−
100 R
U
−1
⋅ C v ⋅ (∆P (P1 + P2 ) SG f )
0.5
Equal Percentage Valves : Flow = 3.22 ⋅ R 100
where
P1 and P2 = Upstream and downstream pressure, respectively
P
0.5
∆Ps =P1 − 0.96 − 0.28 v
P
Pc v
88
CC-DYNAMICS Version 5.5 User’s Guide
The above describes the typical set up for a PID Control system in CC-DYNAMICS. There are certain
important variations and expressions of the PID control system, which should be noted:
1. CASCADE CONTROL SYSTEMS
In a cascade control system, the valve is controlled by a slave controller which is in turn controlled by
a master controller. In this setup, there are two set point variables, one for each controller. The
master controller influences the behavior of the slave by changing its set point value. This changes
the magnitude (and sometimes the sign) of the error. This effect “cascades” to the control valve.
Sm
PIDm
Measured Variable
Adjusts set point (Set point variable
Slows sensor signal Number 1)
PIDs
Ss
Adjust valve position
Measured Variable
(Set point variable
Number 2)
89
User’s Guide CC-DYNAMICS Version 5.5
b. The master controller uses this signal to compute the error and a controller output signal. This
signal will be in milliamps and will be between the maximum and minimum allowable controller
output signals.
c. The slave controller, PIDs, will use the signal from PIDm to determine what its new set point
should be. This is done by interpolating:
P − Pmin S − Smin
=
Pmax − Pmin Smax − Smin
where
P = The current signal from PIDm
Pmax = The maximum signal from PIDm
Pmin = The minimum signal from PIDm
S = The new set point value of measured variable No. 2
Sma = The maximum set point value of measured variable No. 2
Smin = The minimum set point value of measured variable No. 2
d. The slave controller then generates a new PID controller signal to the control valve.
e. The control valve adjusts its position and therefore the flow through the valve.
2. SPLIT RANGE CONTROLLERS
Split range controllers are PID Controllers that control two valves over two mutually exclusive ranges.
To illustrate, consider the following batch reactor and its control system.
90
CC-DYNAMICS Version 5.5 User’s Guide
Temperature transmitter
TT
V-3
FS
Steam
TM V-1
TSET
Cooling
water Temperature Set point
outltet controller generator
Temperature
sensor V-2
T
V
CA Cooling water
V-4 FW inlet
CB
Steam Outlet
Steam is initially fed into the jacket to heat up the system to temperatures at which the consecutive
reactions begin. Then cooling water must be used in the jacket to remove the exothermic heats of the
reactions.
The output signal of the temperature controller goes to two split-ranged valves, a steam and a water
valve. The valves will be adjusted so that the stream valve is wide open when the controller output signal,
P, equals 20 milliamps and is closed at P = 12 milliamps (i.e., half the full range of the controller output).
The water valve will be closed at P = 12 milliamps and wide open at P = 4 milliamps. The reason for
hooking up the valves in this manner is to have the correct fail-safe action in the event of an instrument
failure. The steam valve will be set to fail closed and the cooling water valve will be set to fail open.
In CC-ReACS, split range control systems are set up in the following way:
a. Identify the two valves to be controlled by the PID controller in the PID Controller dialog box (for
input). Now both control valves will receive the controller output signal.
b. Select the valve coefficients, Av and Bv, so that the valve opens mutually exclusive ranges.
Continuing the above example, we would proceed as follows:
i. Specify the steam control valve, V-1, and the cooling water control valve, V-2, as the two
valves to be controlled by the PID Controller, TC-1. This done on the PID Controller dialog
box.
ii. Compute Av and Bv for the steam valve:
• At P = 20 milliamps, the valve is 100% open.
91
User’s Guide CC-DYNAMICS Version 5.5
92
CC-DYNAMICS Version 5.5 User’s Guide
The control valve calculates the flow rate through the valve based on the output signal it receives from a
controller. Each control valve, therefore, must have a designated controller ID as part of its input. The
module can handle compressible and incompressible flow as well as critical and sub-critical flow. The
control valve calculates the following variables at each time step:
1. The valve position.
2. The flow through the valve.
The flow rate of the inlet and outlet streams will be reset to the control valve calculated flow.
The output from the controller is used by the control valve to determine the valve position, that is, how far
open (in percentages) the valve is at any point in time. The valve position, U, is determined as follows:
dU
Tv + U = A v ⋅P + Bv
dt
where
Tv = Valve time constant; default = 0
U = Valve position (in fractions); must be between 0 and 1
P = Controller output signal in milliamps
Av, Bv = Valve constants; defaults: Av = 0.0625 and Bv = 0.25
Normally the controller output, P, is between 4 and 20 milliamperes. The valve position, U, varies
between 0 and 1.
The valve position is related to the valve flow rate by the following equations:
Cf = Critical flow factor, usually supplied by the user; default = 0.98
P
0.5
∆Ps = P1 − 0.96 − 0.28 v
P
Pc v
93
User’s Guide CC-DYNAMICS Version 5.5
PARAMETER DEFINITIONS
94
CC-DYNAMICS Version 5.5 User’s Guide
Flow Coefficient, Cv
Size, inches Single Seat Double Seat
3/4 - 8
1 9 12
1-1/4 14 18
1-1/2 21 28
2 36 48
2-1/2 54 72
3 75 110
4 124 195
6 270 450
8 480 750
10 750 1160
12 1080 1620
14 1470 2000
16 1920 2560
Rangeability:
Rangeability is the ratio of the maximum to minimum controllable flow. This value is most important for
equal percentage valves because the relationship of R to U is non-linear (see the equations under “Valve
Type” for more information). The default is 10.
Controller ID:
Enter the equipment ID number of the controller (PIDC) which controls this valve. If no controller ID is
specified, the program will assume the valve is manual and the valve position will be set to valve position
entered in the field below.
Valve Position (%):
The valve position ranges from 0 (closed) to 100 (fully open). If the valve is controlled by a controller, the
value is determined by the controller signal. If no controller is specified, the valve is assumed to be
manual and the user must enter a value here. Units are percentages.
CONTROLLER/VALVE POSITION
Valve Time Constant:
The time constant, Tv, is used in the time position calculation below:
95
User’s Guide CC-DYNAMICS Version 5.5
dU
Tv + U = A v ⋅ P + Bv
dt
dU
Tv must be positive; therefore, the term Tv tends to slow down the valve response to the controller
dt
signal. The larger the value of this term, the more it slows down the response.
Valve Av and Bv:
These are the Av and Bv terms in the control valve position equation above. In the default condition, the
dU
controller output is assumed to be between 4 and 20 milliamps and the term Tv = 0 (zero) . Since at
dt
the minimum position, the valve is closed and U = 0 and at the maximum position the valve is fully open
and U = l, then the defaults are determined as:
0 = Av * 4 + Bv
1 = Av * 20 + Bv
therefore
Av = 0.0625
Bv = 0.25
Valve Mode:
The control valve may be manually controlled, i.e., the valve position, instead of being set by a PID
controller, may be specifically fixed by the user using any of the following options:
i. Fix the flowrate through the valve and have the program calculate the required valve
position. If this option is chosen, the flowrate through the valve is set equal to the inlet
stream flowrate.
ii. Fix the valve position, and have CC-ReACS calculate the flow through the valve. If this
option is selected, the valve position must be specified in the Valve Position field described
above.
iii. Fix both the flowrate through the valve and the valve position and have the program
calculate the valve outlet pressure. If this option is selected, the fixed flowrate is taken to be
the inlet stream flowrate and the valve position must be specified in the Valve Position field
described above.
Please note the following:
1. These valves may be fixed at a single valve or scheduled using the RAMP Controller.
If both manual control and PID control are set up or "turned on" for a control valve, the PID control is
ignored and the manual control valves are the ones used.
96
CC-DYNAMICS Version 5.5 User’s Guide
Valve Type:
Choose from either linear or equal percentage valves.
Linear valves relate the actual valve flow to the capacity valve flow by the following relation:
U 1
Actual Flow = 1 − ( Valve Capacity )
100 R
Equal percentage valves relate actual flow to capacity valve flow as follows:
U
−1
Actual Flow = R 100 ( Valve Capacity )
Valve Operation:
This combo box makes it possible to select different options to simulate malfunctions and manually
operated valves. Each option allows the user or an operator training system such as CC-OTS to
simulate malfunctions and manual operations of CVAL:
Normal: CVAL will operate properly and will set the flow rate according to the simulation
parameters.
Power failure: CVAL will set flow rate to zero regardless of other simulation parameters.
Manually close: CVAL will set flow rate to zero regardless of other simulation parameters.
Manually open: CVAL will calculate flow rates at 100% open valve position regardless of other
simulation parameters such as PID controllers.
Manually set valve position: CVAL will allow the user to input a specified valve position and
calculate the flow rate, overriding any other simulation parameter.
Critical Flow Factor:
The critical flow factor, Cf, is used to determine if the flow through the valve is above or below critical
velocity. If flow is subcritical, the valve position determines the flow. If critical flow conditions exist, then
flow is calculated as follows:
Non-compressible critical flow:
Cv ⋅ Cf
Q=
SG f
∆Ps
P
0.5
∆ Ps = P1 − 0.96 − 0.28 v
P
Pc v
97
User’s Guide CC-DYNAMICS Version 5.5
where
Q = Flow, US gpm for liquids; SCFH for gases
Cv = Valve flow coefficient
Cf = Critical flow factor
P1 = Inlet pressure in psia
Pc = Critical pressure of the fluid
SGf = Specific gravity of fluid; liquids referred to water at standard conditions; gases
referred to air at standard conditions
T = Flow temperature, R
Downstream Pressure:
The control valve downstream pressure can be specified here. If downstream pressure is not specified,
the output pressure of the valve will be determined by the pressure of the downstream unit operation
which is specified in the field labeled Destination ID or by the jacket pressure (if so specified in the PID
Controller input.
Supply Pressure:
Enter the control valve supply pressure. If not specified, the pressure of the inlet stream will be used.
98
CC-DYNAMICS Version 5.5 User’s Guide
Static head:
If an elevation change is to be included in the flow calculation, enter this value in this field. The elevation
change will affect the available pressure drop across the valve, and therefore it will affect the flow rate as
well.
Bias option:
The actual input of the CVAL will set the output signal from the PID Controller + Bias
CALCULATED RESULTS
Calc. Flow Rate:
The value displayed in this field is the current instantaneous flow rate through the valve.
Controller Output:
This is the value currently being received from the controller.
Steady State Position:
This is the steady state valve position determined from the steady state controller output, P0. (See the
“PID Controller Field Descriptions”.)
Controller Output At Steady State:
This is the output signal from the controller at steady state. CC-DYNAMICS calculates this at the initial
valve position, assumed to be closed.
TOPOLOGY
A control valve has one input and up to two outlets. If two outlets are present, the first outlet is vapor
and the second outlet is liquid.
The PID Controller continuously measures the user specified variable, and based upon the specified set
point for that variable, sends a controller output signal (in milliamps) to the control valve. The controller
can include proportional, derivative, and/or integral action in its signal computation. Cascade and split
range controllers are permitted. The user may specify the control loop and controller limits if so desired.
Also, the controller time step may be set to a smaller value than the flowsheet integration time step.
99
User’s Guide CC-DYNAMICS Version 5.5
The controller UnitOp is actually a sensor and controller, i.e., it measures its own input as well as
calculating its output. The controller measures some variables in the flowsheet (generally a batch
reactor variable) and from this computes the controller input in milliamps. From this input and the user-
defined set point, the controller calculates its output, which is subsequently used by the control valve.
The specific logic is as follows:
1. The unit reads the current value of the user identified measured variable.
2. The controller input is calculated using the following expression:
C in = A c + B c ⋅ X + C c ⋅ X 2
where
Cin = Controller input in milliamps
X = Current value of the measured variable
Ac, Bc, = Coefficients calculated by CC-ReACS
Cc
100
P= ⋅ error = proportional action
PB
100 1
⋅ (error ) dt = integral action
I=
PB
⋅
Ti
∫
100 d(error )
D= ⋅Td ⋅ = derivative action
PB dt
P0 = controller signal at steady state
and
PB = Proportional band
Ti = Integral time constant in minutes
Td = Derivative time constant in minutes
100
CC-DYNAMICS Version 5.5 User’s Guide
Activate Controller:
This choice box turns the control on and off while the simulation is running.
Set Point:
The value of the set point of measured variable is entered in this field. The engineering units for this
entry are taken from the flowsheet global engineering units and are displayed to the right of the field.
Steady State Output (PO):
P0 is the value of the controller signal (in milliamps) at the steady state. If this field is left blank, P0 will be
calculated by the program based upon the initial state of the process.
The steady state output term allows the controller to function linearly on either side of the set point.
Setting P0 = 0 starts the system with the valve closed and the controller will open the valve slowly in
response to the error signal.
Proportional Band (PB):
The proportional band (PB) helps determine the speed of the controller output signal according to the
above controller output equation.
Increasing PB will decrease the sensitivity of the controller and give a slower response. PB must be
positive.
Proportional action alone is normally insufficient to control a process.
101
User’s Guide CC-DYNAMICS Version 5.5
CONTROLLER/SENSOR FUNCTION
The functional relationship between the controller input and the output from the sensor is as follows:
2
Cin = Ac + Bc ⋅ X + Cc ⋅ X
Cin = Controller input in milliamps
X = Value of the measured variable in the user specified engineering units
The coefficients Ac , Bc, Cc are calculated by the program using the function type and variables shown
below. If the sensor function is to be linear, then Ac and Bc are calculated. If the sensor function is to be
quadratic, then Bc and Cc are calculated.
Controller/Sensor Function:
The user may specify whether the sensor function is linear or quadratic. The default is linear. The
quadratic form should be selected if the measured variable is flow rate. Otherwise, linear can be used.
Variable Min and Variable Max:
The user may specify the minimum and maximum sensor output values if desired. The default values
are 4 and 20 milliamps, respectively.
Ctrl Input Min and Ctrl Input Max:
The user must specify the minimum and maximum values of the measured variable. This is done in
these two fields. The program will then determine the coefficients for the above sensor equation.
102
CC-DYNAMICS Version 5.5 User’s Guide
Error Definition:
At the user’s option, the error may be defined in one of two ways:
Error = X - Xset
Error = Xset - X
where
X = Controller input (in milliamps) at the current value of the measured variable.
Xset = Controller input (in milliamps) at the set point value of the measured variable.
Equation (1) above should be used when the function being controlled is for cooling, pressure control, or
level control.
Equation (2) above should be used when the function being controlled is for heating or flow rate control.
These are guidelines. The general rule is as follows. The user should select the error function which
ensures that the control variable will move toward the set point if an error exists. For instance, if the
service being controlled is steam flow rate to the jacket and the set point is the reactor temperature, the
function Error = Xset - X should be selected. This is true because when the reactor temperature is below
the set point, the error will be positive and the steam valve will open. If in the same situation, Error = X -
Xset was chosen, the error would be negative and the steam valve would close, thus moving away from
our target, not closer to it.
MEASURED OBJECT
The measured object is the set point variable. The set point is the condition which must be achieved by
the control system. In other words, the measured variable must equal the set point before the controller
will stop resetting the control valve.
To let CC-DYNAMICS know which variable is to be measured, the user must do the following:
1. Identify whether the variable is contained in a stream or unit operation.
2. Identify which stream or unit operation is involved. This is the UnitOp or Stream ID.
3. Specify the variable or parameter of the stream or unit operation.
4. Specify the type of engineering units the variable uses.
5. Specify which component the measured variable applies to (if applicable).
The procedure is as follows:
1. Identify whether the variable is a stream or a unit operation variable by clicking the appropriate circle
at the field labeled “Stream” or “Equipment”.
2. In the “Measured Object ID” field, enter either the stream number or the equipment number in which
the measured variable is located.
103
User’s Guide CC-DYNAMICS Version 5.5
3. In the “Variable” field select the variable from the list provided by:
• Clicking on the field to open the list;
• Scrolling to the desired selection;
• Clicking on the desired selection.
4. Specify the type of engineering units to be used by making the appropriate selection in the “Variable
unit” field. Do this by:
• Clicking on the field to open the list;
• Scrolling to the desired selection;
• Clicking on the desired selection.
5. If the measured variable is a selection which requires component identification, such as “mole
fraction or “reaction rate”, you must identify the relevant component in the “Comp” field. The
procedure is:
• Click on the field to open the component list;
• Scroll to the relevant components;
• Click on the component to select it.
Stream or Equipment:
The user must identify if the measured variable is a stream variable or an equipment parameter. This is
done be clicking on the appropriate circle in this field.
ID Number:
The user must specify the ID number of the stream or piece of equipment that the measured object is
associated with.
Variable:
Each UnitOp or Stream has a list of variables, which can be used as set point variables. This list is
contained in this field and can be displayed by clicking on it. From this list, locate the desired variable
and click on it.
Component:
This field contained a list of all the components in the current flowsheet. If a component variable, such
as mole fraction or mass flow rate is selected as the “Measured variable” above, then the user must
identify which component from this “Measured component” list.
To display the list, click anywhere on the field. Then locate the relevant component by scrolling. To
select the component, click on it.
Variable unit:
Use this field to identify the type of engineering units that apply to the measured variable. In other
words, if the measured variable is the reactor temperature, selected “2 Temperature” from the list. This
will instruct the program to apply the global flowsheet engineering units to the measured variable.
Otherwise, internal engineering units will be used.
104
CC-DYNAMICS Version 5.5 User’s Guide
105
User’s Guide CC-DYNAMICS Version 5.5
CALCULATED RESULTS
Integral (Error * Dt):
If integral action is specified (i.e., if Ti is specified), the integral contribution to the controller output
function will be shown here.
Error:
The last computed error is displayed here.
Error = X- Xset; or Error = Xset – X
X = Current sensor input in milliamps
Xset = Sensor input at the set point in milliamps.
Control Output:
The last calculated controller output (Pout in milliamps) is displayed here.
IAE:
This field contains the integral average error.
ISE:
This field displays the integral squared error.
Process Value:
This field contains the current value of the measured variable.
106
CC-DYNAMICS Version 5.5 User’s Guide
F1 V1
F2 V2
F3
L1
Q2 LL
L2
HL
Figure 2
The features and capabilities of the dynamic vessel model are summarized below:
1. Up to three feed streams, two vapor outlet streams and two liquid outlet streams, including utilities.
2. Vapor-liquid and Vapor-liquid-liquid phase calculations are available.
3. Light and heavy liquid phases can be accumulated up to user specified level limits.
4. The vessel operating pressure can be specified or calculated. In other words, pressure can be fixed
or dynamic.
5. Four calculation modes are available.
6. The amount of vapor leaving the vessel can be fixed, controlled, or determined by a venting
calculation.
7. The amount of liquid exiting the vessel can be a fixed valve or set to the amount of the liquid
overflowing a specified liquid level.
8. Multiple vessel geometries can be specified.
9. Safety relief valve performance can be simulated.
10. May be included as a larger part of a pipe network. This includes the static head of the liquid level
above the inlet nozzle (for piping networks upstream) and the static head in a liquid outlet stream.
The following major features of the dynamic vessel model are described below:
1. The pressure calculations
2. The calculation modes
3. Maintaining liquid levels by decanting
107
User’s Guide CC-DYNAMICS Version 5.5
The vessel pressure is calculated by doing a constant volume flash under the current conditions. The
program holds the vessel volume constant and varies the vessel pressure until the sum of the vapor and
liquid volumes equals the vessel volume. As the conditions change the pressure changes.
The following points should be noted regarding the pressure calculation:
1. If the pressure is to be calculated, the flowrate of the vapor vent or outlet stream must be specified.
If it is not, the problem is under specified. However, this specification can be made explicitly by the
user by scheduling the vapor flowrate, or it can be made implicitly using a PID Control system. An
example of this would be a pressure control system where the vapor flowrate is adjusted to maintain
a desired vessel pressure.
2. Specification of an initial charge is optional, but if done can produce certain problems the user
needs to be aware of. Frequently, the initial charge specifications will produce volumes that do not
match the vessel volume. If the pressure is to be calculated, this can produce unwanted results
unless certain conventions are adopted to manage this situation. In CC-DYNAMICS the following
conventions are adopted:
a. If the liquid present exceeds the vessel capacity, an error message is issued and the simulation
will not proceed.
b. If the initial charge is subcooled, then the program will do an adiabatic flash to reset the
temperature and pressure to values, which fill the vessel. A warning message will be issued.
c. If the initial charge is two-phase at the specified temperature and pressure, and the sum of the
vapor and liquid volume is not equal to the vessel volume, a warning message will be issued. If
the user chooses to go ahead with the simulation, then the program proceeds as follows:
• The vapor and liquid amounts and compositions are determined.
• The available vapor space is determined by subtracting the liquid volume from the vessel
volume.
AVS = RV – LV
where
AVS = Available vapor space
RV = Vessel volume
LV = Liquid volume
108
CC-DYNAMICS Version 5.5 User’s Guide
where
EV = Excess vapor
VV = Vapor volume of the initial charge
The excess vapor is negative if the initial charge does not fill the vessel.
• The excess vapor is removed from the initial charge so that the vapor space equals the
available space (AVS). If the excess volume is negative, this means adding enough vapor
(of the same composition as the initial vapor) to fill the available vapor space.
• The end result is the composition of any volatile component may change slightly from what
was specified. If you receive a warning message saying the initial charge has been scaled
to fit the available volume, please be sure to check your initial charge
The dynamic vessel module requires the user to specify both a thermal mode and a pressure mode for
calculation. The available thermal modes are adiabatic, flash with heat duty, flash with UA & utility and
isothermal. The pressure mode options are fixed pressure or calculated pressure. The user must
specify which option is to be used in both calculation modes for the calculation to proceed. If no
specification is made, defaults are assumed.
The Thermal Mode:
Note: The pressure used in the calculations for any of the following thermal modes depends on the
pressure calculation mode selected.
The thermal mode options are:
• Adiabatic – This mode assumes that no heat passes through the walls of the vessel. At
each time step a flash is performed using the inlet stream(s) composition and enthalpy.
• Flash with heat duty – This mode assumes a constant, user specified heat duty on the
vessel. At each time step a flash is performed using the inlet stream(s) composition and
enthalpy plus the specified duty.
• Flash with UA and Utility – In this mode you must enter the dynamic vessel U (overall
heat transfer coefficient) and area. The heat duty is calculated using the equation,
Q = U ⋅ A ⋅ ∆T
109
User’s Guide CC-DYNAMICS Version 5.5
In this example, Stream 10 is the utility inlet, stream 16 is the utility outlet.
At each time step a flash is performed using the inlet stream(s) composition and enthalpy
plus the computed heat transfer determined from the above equation.
• Isothermal – In this mode the temperature is fixed. At each time step a flash is performed
using the inlet stream(s) composition and the specified temperature. A required heat duty
is computed.
The Pressure Modes:
• Fixed pressure – Using this option, the user specifies the vessel operating pressure. This
pressure is then the one used in the flashes mentioned above in the thermal modes.
During fixed pressure simulation if the vapor is in excess of the available vapor space, the
excess vapor is vented. If the computed vapor does not fill the available vapor space, the
difference is ignored.
• Calculated pressure – If the pressure is to be calculated, the flow through the vapor vent
must be specified (it may be zero, but it must be specified). The pressure is then varied
until the sum of the vapor volume and the liquid volume equals the vessel volume.
The flow rate of the liquid outlet streams can be determined in a number of ways. One of these is by
decanting a liquid in excess of a specified liquid level. Since the dynamic vessel model can handle two
liquid phases if requested, it is important to know the decanting model in order to use it correctly.
The model can be summarized in the following way:
If HL> HLL; then HLF = HL – HLL, and
If TL> LLL; then LLF = LL + HLL – LLL
110
CC-DYNAMICS Version 5.5 User’s Guide
where
HL = The amount of heavy liquid present before decanting
LL = The amount of light liquid present before decanting
TL = The amount of total liquid present before decanting: TL = HL + LL
HLL = The volume of the vessel made available for accumulating heavy liquid
where
Lh = The specified heavy liquid level
π = pi
r = The radius of the vessel
LLL = The volume which must be filled before any decanting of light liquid can occur
where
LL = The specified light liquid level
111
User’s Guide CC-DYNAMICS Version 5.5
The dynamic vessel model requires that a vapor outlet or vent be provided even if it is not used. This
means you must draw one on the flowsheet.
In addition, the method for determining the flow through this vent must also be specified. The following
options are available:
1. The flow rate can be fixed at a specified valve throughout the simulation.
2. The flowrate can be adjusted by a PID control system.
3. The flowrate can be reset at each time step using a RAMP controller.
4. The flowrate can be calculated using relief vent methods. The flow through the vapor vent would be
that amount that the safety relief valve (or rupture disk) can pass.
5. The flowrate can be set to the amount of vapor generation in excess of the available vapor space.
In this mode the pressure must be specified.
The following rules apply:
1. If the pressure is to be dynamically calculated during the simulation, then the vapor flowrate must be
specified, set by some form of controller, or determined using relief vent geometry.
2. Flow through the vapor vent can be two-phase if using relief geometry.
112
CC-DYNAMICS Version 5.5 User’s Guide
3. If the calculation mode is set to the fixed pressure mode, the vapor flow mode is ignored and relief
vent rating cannot be used.
The CHEMCAD relief vent model is explained in detail in the on-line help system. No effort is made to
repeat that information here. The following points, however, are specific to CC-DYNAMICS and should
be noted.
1. Only the relief vent rating calculations can be performed in CC-DYNAMICS. In other words, the size
of the relief valve and/or rupture disk must be specified. CC-DYNAMICS will then calculate the
amount and composition, and vapor quality of the material, which passes through the vent. This
material is then removed form the heat and material balance.
2. Only the vent pressure is determined dynamically. The valve (disk) backpressure must be specified
by the user and is fixed throughout the simulation.
3. If a fire model is selected for the relief vent calculation, then the fire heat input is in addition to any
other specified heat input.
4. Relief vent calculation cannot be done if the calculation mode is fixed pressure or isothermal.
The Dynamic Vessel enables the user to model vessel holdups in a dynamic fashion. Features of the
dynamic vessel model include:
• Horizontal or vertical vessels
• Ellipsoidal, F & D, Flat, or hemispherical
• Fixed pressure or calculated pressure modes
• Isothermal or non-isothermal modes
• Multiple liquid phases
• Level control
• Specified flow options
• Relief vent rating
113
User’s Guide CC-DYNAMICS Version 5.5
GEOMETRY
Enter the diameter and length of the vessel. Length is defined as the tangent-to-tangent cylinder length.
The diameter of the vessel is measured at 90 degrees to the long axis.
Vessel Type:
Specify whether the vessel is horizontal or vertical. This is required input. The default is vertical.
Diameter:
Enter the inside diameter of the vessel measured at 90 degrees to the long axis.
Cylinder height:
Enter the cylinder length defined as the distance between the vessel heads.
Vessel Head Type:
Select the vessel head type. Available options are:
• Ellipsoidal (default)
• Bumped F & D (flange and dish)
• Flat
• Hemispherical
Head Ratio:
Enter the head ratio defined as:
overall vessel length − cylinder length
HR =
vessel diameter
114
CC-DYNAMICS Version 5.5 User’s Guide
115
User’s Guide CC-DYNAMICS Version 5.5
INITIAL CONDITIONS:
Initial Charge Options
• From outlet Stream Composition: Default mode. Specify an initial liquid level. Specify
composition of an attached outlet stream on the flowsheet. During the first time step the vessel
will be filled with material based on the composition of the outlet stream. The program assumes
that the vessel is well mixed and that the outlet at time zero represents the overall composition
of material in the vessel.
• Specify composition & liquid level: This mode activates an initial charge dialog when the user
presses OK. Specify the overall composition of the initial charge. CC-DYNAMICS will adjust
the total flowrate to reach the specified liquid level, based on the specified overall composition.
Specify an initial liquid level.
• Specify mass, calculate liquid level: This mode activates an initial charge dialog when the user
presses OK. Specify the composition of the initial charge. Specify a total flow, which
represents the total material for the initial charge. During the first time step the program will
calculate the liquid level.
Initial Liquid level 1:Specify the initial liquid level in the vessel. If there are two liquid phases, this is the
liqht phase. For use with initial charge mode 0 from outlet stream and 1 specify composition & liquid
level of charge. Default is zero.
Initial liquid level 2: If there are two liquid phases this is the heavy phase. Specify the level of the
second liquid phase (if present). Default is zero.
Initial utility outlet Temperature: If a utility stream is connected (for vessel mode 2 Flash with UA &
Utility) specify the outlet temperature of the utility. The default initial utility stream outlet temperature is
the utility stream inlet temperature with the assumption that the heat transfer is from latent heat.
OPTIONAL INPUTS:
Inlet nozzle position from top:
Default is 0 (inlet at top of vessel). Specify vertical location for the inlet nozzle. Only if you check the
liquid static head is option for this vessel, the height of liquid above the inlet nozzle will exert pressure
head on the inlet stream. This is useful if the dynamic vessel is part of an equation-based-network with
inlet flowrate based on backpressure from the vessel.
Include static head in output streams:
If outlets liquid streams of the vessel are connected to piping networks, checking this option will add the
static head of the liquid level in the vessel to the specified pressure in the vessel. This feature allows
performing more realistic piping network simulations in dynamic mode.
Three phase flash:
Checkmark this field to allow three phase (vapor-liquid- liquid) calculations for the dynamic vessel. A
light and heavy liquid level will be calculated. If two liquid outlets are connected, the liquid phases will
separate at the outlets. The Global K Value setting (ThermoPhysical menu > K-Values) for vapor –
liquid – liquid must be checked for this setting to apply.
116
CC-DYNAMICS Version 5.5 User’s Guide
117
User’s Guide CC-DYNAMICS Version 5.5
118
CC-DYNAMICS Version 5.5 User’s Guide
Vessel Model:
The fluid characterization of the vessel under relief conditions, options are as follows:
Bubbly
Churn-Turbulent
Homogenous
The Bubbly vessel model assumes uniform vapor generation in the liquid phase with vapor/liquid
disengagement within vessel. The Churn-Turbulent model assumes uniform vapor generation; however,
with Churn-Turbulent, there is greater vapor/liquid disengagement. The Homogenous vessel model
assumes there is no vapor/liquid disengagement and is useful for viscous fluids or short venting times.
The “Non-boiling height” modification of the Churn-Turbulent vessel model has not been included in this
program.
Device Type:
The device type can be a relief valve, a rupture disk, or a relief valve followed by a rupture disk.
C0:
C0 is a data correlation parameter for Bubbly and Churn-Turbulent models. Normal values range from
1.0 to 1.5. Generally speaking, the greater C0, the less likely two-phase venting will occur. Default is
1.2.
Nozzle Area:
The cross sectional area of the relief system nozzle.
Discharge Coefficient:
This is the roughness factor of the relief device. For relief valves, this has a value of 0.975. For rupture
discs, this is typically 0.625.
Above Ground:
Please enter the elevation of the vessel above the pad level.
PRESSURE DATA
Set Pressure:
The “lift” or opening pressure of the relief system. Typically this number is within 10% of the maximum
design pressure for the vessel.
Back Pressure:
The flare or relief system pressure on the backside of the valve. When the vent is connected to a NODE
UnitOp, this field will be the backpressure for the relief device until the relief device opens. In such a
case backpressure will then be calculated by the piping network.
Max pressure:
Pressure rating of the vessel.
Vent Flow Model:
The vent flow model may be selected from the following list (see DIERS Handbook for full descriptions):
HEM (Homogenous Equilibrium Model)
ERM (Equilibrium Rate Model)
119
User’s Guide CC-DYNAMICS Version 5.5
Henry-Fauske HNE
Non_Flashing Liquid
Single Phase Vapor
Adequate fire facilities exist:
This is used in the API 520/521 fire model. Select from options: Adequate fire and drainage facilities
exist or adequate fire and drainage facilities do not exist.
Fire Model:
Select one of the following fire models:
0 No Fire
1 API-520/521
2 API-2000
3 OSHA 1910.106
4 NFPA-30
F Factor:
This factor is for adjusting the fire heat load for the environment. Below is a list of standard values:
Vessel configuration F Factor
Bare Vessel 1.0
Insulated Vessel 0.3
Sprinkler System 0.3
Both Insulation and Sprinklers 0.15
120
CC-DYNAMICS Version 5.5 User’s Guide
Vessel Temperature
Vessel Pressure
Liquid Level 1
This is the liquid level for the light phase liquid. If there is only one phase of liquid, this is the total liquid
level.
Liquid Level 2
This is the liquid level for the heavy phase liquid.
Vessel Volume
This is the calculated volume of the vessel.
Liquid1 Volume
This is the liquid volume for the light liquid phase. If there is only one liquid phase, this is the total liquid
volume.
Liquid 2 Volume
This is the liquid volume for the heavy liquid phase. If there is only one liquid phase, this is shown as
zero.
Vapor Volume
This is the vapor headspace volume.
Overall heat duty
This is the total heat transferred to/from the vessel.
121
User’s Guide CC-DYNAMICS Version 5.5
TOPOLOGY
The dynamic vessel may have up to 3 inputs and 3 outlets; the inlets may be in any order. The outlets
are listed with the vapor outlet first, followed by the heavy liquid outlet, and then the light liquid outlet. In
the event there is only a single liquid phase, all liquid flows out the bottom outlet. Utility streams are
connected to the utility coil section of the symbol.
Other unit operations modules are also provided with a CC-DYNAMICS, CC-ReACS, or CC-DCOLUMN
license.
These include:
• The RAMP Controller
• The Time Delay
• The Time Switch
• Commonly used steady state unit operation
The Ramp controller unit is used to change various operating parameters with respect to time. In
dynamic simulations, the scheduling ramp may be used to simulate operator functions such as opening a
valve at time = t.
Each scheduled ramp can only act on a single parameter.
PARAMETER DEFINITIONS
Controller Type RAMP can control both: inlet streams and UnitOp parameters:
1. Stream: This mode causes the RAMP to adjust an inlet stream variable during simulation.
2. UnitOp: This mode causes the RAMP to adjust a unit operations parameter during the simulation.
Stream/UnitOp ID:
Enter the ID number for the stream or UnitOp, which has the variable to be reset by the RAMP.
Variable Number:
This field is used to identify the variable, which is to be continuously reset by the RAMP. If this variable
is from a dynamic UnitOp or from a stream, a list of the available variables will be displayed and the user
may click on the desired item to select it. If the variable is from a steady state UnitOp then you must
type in the Variable Number (Variable Numbers can be found in the on-line manual) Time (Min) And
122
CC-DYNAMICS Version 5.5 User’s Guide
Value:
This is a spreadsheet style chart of how the value of the parameter changes in time. CHEMCAD
automatically interpolates between values to determine the value for each time slice in the dynamic
simulation.
Controller Mode:
There are four different ways of simulating disturbances. Each one has its own options.
• Use table below: The user can input a table of variable values vs. time directly.
• Random disturbance: The user can input a minimum and maximum value for RAMP to set the
variable value randomly.
• Sine wave: The user can input the parameters to simulate a sine wave disturbance.
123
User’s Guide CC-DYNAMICS Version 5.5
• Disable ramp control: Using this option will disable the RAMP, and the variable will not be
adjusted.
The Time Delay unit is used to simulate delays in dynamic simulation, such as pipe delays.
124
CC-DYNAMICS Version 5.5 User’s Guide
Delay time:
The user specifies the duration of the time delay which the stream experiences.
TOPOLOGY
Time delays have only one inlet and one outlet.
The Time Switch UnitOp is a process flow scheduling tool. It provides a time schedule for the direction
of these flows.
The dialog box will contain one row of fields for each outlet stream coming form the time switch. This
now will enable the user to direct all process input (to the time switch) through the outlet stream during
the times specified.
There are four fields for each row. These are:
1. Outlet No.
2. Starting time
3. End time
4. Deactivate switch
These are described below:
Outlet No.: Within the Time switch, streams are identified by position number. Positions are number
from the outside in. In other words, the outlet position located the farthest from the inlet position is
position number one. In the above example dialog box, this position is labeled “Stream 1”. The outlet
position located closest to the inlet position will receive the highest position number. In the above
example dialog box, this position is labeled “Stream 3”. All other positions are relative to these positions.
These statements apply only to the standard Time Switch icon (the icon supplied as part of the CC-
ReACS program). The user can create his/her own icon, which follows different valves.
125
User’s Guide CC-DYNAMICS Version 5.5
Starting time: This field designates when flow through this outlet will begin. Starting time is specified in
minutes from time zero.
End time: This field designates when flow through this outlet is to cease. End time is specified in
minutes from time zero.
Deactivate Switch: This checkbox turns the schedule for the outlet off.
TOPOLOGY
The Time Switch UnitOp has one inlet stream and up to eight outlet streams.
In addition to the unit operations modules already described, your CC-DYNAMICS, CC-ReACS, or CC-
DCOLUMN license entitles you to use other unit operations modules within the CHEMCAD system. The
one restriction on the use of these modules is that they can only be used in dynamic mode.
The following unit operations in the CHEMCAD library are available for use with CC-ReACS, CC-
DCOLUMN, or CC-DYNAMICS without an additional license:
• Calculator
• Component Separator
• Compressor
• Controller
• Divider
• Excel Unit
• Fired heater
• Flash vessel
• Heat exchanger
• LLV flash
• Mixer
• Node
• Phase generator
• Pump
• Stream Reference
• Valve
• User-Added
• Subflowsheet
126
CC-DYNAMICS Version 5.5 User’s Guide
In addition to this list, the following unit operations in the CHEMCAD library are available for use with
CC-DCOLUMN without an additional license:
• SCDS distillation
• Tower distillation
• Tower Plus distillation
Whenever a steady state unit operation is used in a dynamic flowsheet, the user is making the implicit
assumption that the dynamics of that unit operation are very, very fast. Technically, they are assumed to
be instantaneous. If this is not a reasonable approximation, consider using the tank and time delay
UnitOps to build in some of the dynamic effects of these modules.
DYNAMIC TECHNIQUES
This section is intended to help you with doing dynamic simulation work. Dynamic simulation involves
activities much more complex than those encountered in steady state calculations. The user must
gather more information about the process under consideration, and knowledge about control systems
and instrumentation is advantageous.
Before any complex control system of a technology is installed, a dynamic simulator can be used to
analyze the system, to assess its future performance, and to detect possible problems or infeasible
schemes. Dynamic simulation can also help during process start-up and in the tuning of the control
system.
Dynamic simulation of industrial technologies requires dynamic mathematical models of unit operations
as well as a special dynamic “engine” or a solver, and reporting subsystem.
CC-ReACS was the first implemented dynamic module of the CHEMCAD Suite. This engineering
software tool was designed to simulate the behavior of batch and semi-batch vessel reactors. CC-
ReACS contains all fundamental dynamic units and the solver for general dynamic simulation.
CC-DCOLUMN is a software tool that involves generalized dynamic simulation distillation columns. It
can be a powerful tool for studies of batch or semi-batch distillation units, and it can be equally well used
for studies of continuous distillation, including complete distillation train of many columns.
The CC-STEADY STATE and CC-DCOLUMN combination is perfect for the design of continuous
distillation systems, where CC-STEADY STATE provides theoretical solution of the problem and
prepares the initial data for dynamic simulation. Similarly, the combination of CC-BATCH and CC-
DCOLUMN is ideal in solving batch and semi-batch distillation systems, as CC-BATCH allows you to
understand behavior of the column before control systems are introduced. CC-BATCH is a CHEMCAD
Suite module for batch and semi-batch distillation.)
The mathematical models of CC-DCOLUMN are extensions to the steady state distillation models
(SCDS, TPLS, TOWR) by a set of differential equations describing the mass, component and heat
balances of a dynamic column. Only the extended dynamic SCDS model can make use of the
component mass transfer model as well.
CC-DCOLUMN follows the general philosophy of the CHEMCAD Suite, that is, the program should be
easy to use. From this point of view, it can be used as a multipurpose and multifunctional unit operation
with a set of built-in process equipment pieces and with a set of built-in control algorithms.
127
User’s Guide CC-DYNAMICS Version 5.5
“Easy to use” does not necessarily mean that the program would be successfully operated by users of
no experience with dynamic simulation, or those who do not know the special dynamic simulation
techniques of the CHEMCAD Suite. This section helps the user to gain this experience.
This section consists of two parts. The first part is a detailed overview of the fundamental techniques of
dynamic simulation using the CHEMCAD Suite. The usage of CC-DCOLUMN is discussed in the
second part. With continuous and batch distillation examples, we will explain the solution of theoretical
and practical problems that can be solved using dynamic simulation.
FUNDAMENTAL TECHNIQUES
The control valve (CVAL) calculates the flow rate through the valve. The terms "the control valve" and
CVAL are used interchangeably in this manual.
Rule 1.
The Control valve has no volume and has no dynamic property, so the mass flow rate at the outlet is
always equal to the mass flow rate at the inlet.
Rule 2.
The user who works with the flowsheet should make use of the calculated flow rate.
Techniques:
1. Place a control valve at inlet stream of a flowsheet. The control valve should directly follow the feed
arrow in the stream. In this case, the flow rate of the inlet and outlet streams will be reset to the flow
calculated by the control valve.
2. Use the “optional mass flow rate transfer” option of CVAL if the source of the inlet stream is a
passive unit. A unit is passive if it cannot take over the calculated flow rate from the control valve.
Typical passive stream source units are stream divider and stream reference models. The following
example shows the technique that uses the stream divider.
128
CC-DYNAMICS Version 5.5 User’s Guide
129
User’s Guide CC-DYNAMICS Version 5.5
This solution means that at every time point (k) the streams – from the source point through the valve -
have identical flow rate values as calculated by the control valve at time point (k-1). The unit operations
have specifications identical to the flow rate calculated by the control valve at time point (k) and
transferred to the divider unit. (The large difference between stream values calculated at step k-1 and
unit operation specifications set at time k results from quick opening of the control valve in this example.)
3. The next technique demonstrates application of the stream reference model.
The settings for stream reference model are:
where
130
CC-DYNAMICS Version 5.5 User’s Guide
Note: With the stream reference model, you should consider conversion of engineering units. The
actual mass flow rate unit of the example above is kg/h, but the SREF defaults to lb/h. CC-
DCOLUMN will copy the internal stored value of mass flow rate = 3041.7971 * 2.20462 = 6706.0146
lb/h from the control valve to the stream reference model. Because of this specific behavior, you
should select lb/h as flow unit in stream reference model.
4. Use the mass flow rate transfer option of active units. A unit is active if it can take over the
calculated flow rate from the control valve. Typical active stream source units are the dynamic
vessel and the dynamic column models. In this case, you should always specify the ID of the
control valve that will calculate the flow rate for the active unit. The next example shows this
technique using a dynamic tower model with controlled bottoms flow rate.
Note: A horizontal vessel is assumed in the dashed box. This is a part of the dynamic
tower model and it is handled by built-in algorithms. (Unit ID of column is 10)
131
User’s Guide CC-DYNAMICS Version 5.5
This information is sufficient for the model; the actual value of flow rate will always be transferred
from unit 13. In this case, there is no need to specify “flow rate transfer” option in the dialog box of
the control valve.
You are allowed, however, to apply the passive unit approach, even if you are working with an
active unit. To do that, you would refrain from applying the “By control valve” method of the active
unit. The “vessel” specification is now:
In the example above, you tell CC-DCOLUMN to fix the flow rate of the bottoms stream to some
value. Then, you instruct CVAL to copy the calculated flow rate directly to the equipment (unit
operation) specification. Both techniques, that is, the active and the passive approach, can be
applied interchangeably with active unit operations of CC-DCOLUMN dynamic modules. (Note: The
active unit operations are: Dynamic Columns, Batch Reactor, and Dynamic Vessel.)
5. The next technique is similar to the previous one. Here we used a separate (discrete) reboiler
system: heat exchanger and vessel. In the picture you can see the column bottom and the vessel
with a liquid level control loop combined together.
132
CC-DYNAMICS Version 5.5 User’s Guide
It is usually much simpler to apply the active unit approach because only one specification is
needed. The following picture demonstrates this approach for the vessel:
The flow rate through the valve is based on the valve position. The actual value of valve position is
stored in the control valve dialog box.
133
User’s Guide CC-DYNAMICS Version 5.5
Rule 1.
If a control valve is not related to a controller, then the user should define a method to set the valve
position. Note that CC-DCOLUMN always displays a warning message when a controller ID is not
defined. From the viewpoint of dynamic simulation, this message can be ignored.
Rule 2.
If the output signal of a PID controller is used to determine the valve position, the control valve must
have a designated controller ID as part of its input.
Techniques:
1. The simplest technique is to set a constant valve position as defined by the user before the start of a
dynamic simulation. This solution is not very typical, because the user cannot modify the valve
position during the simulation.
2. A good and frequently used technique is to define a valve position sequence using RAMP model.
You can see below the flowsheet that makes use of this technique, where the Control Valve ID
number is 3 and the RAMP ID number is 2:
134
CC-DYNAMICS Version 5.5 User’s Guide
The RAMP model sets the valve position (Parameter ID = 11) of the control valve (Unit ID = 3) by
the predefined curve. The time point – value data pairs represent the break points of the continuous
curve. CC-DCOLUMN makes a linear interpolation between these points. With a study of batch
technologies, we can define special control sequences using 0 % and 100 % valve positions (On /
Off or Open / Closed). It is also possible to define special control sequences using the Valve
operation option available on the CVAL dialog (see picture below).
The first picture shows the valve position manipulated by RAMP model. The bottom-left picture
shows the actual flow rate for linear valves and the bottom-right one shows it for an equal
percentage valves.
135
User’s Guide CC-DYNAMICS Version 5.5
A circle indicates the critical regime for an equal percentage valve. Detecting this regime, CC-
DCOLUMN displays a warning message suggesting, either that the user select a linear valve or to
use equal percentage valve of smaller size. From a practical viewpoint, equal percentage valves
are recommended for continuous processes and the suggested working range of these valves is in
the range of 60% -70% opening. For batch technologies or for valves that would be able to close
completely, linear valves should be used, and the maximum flow rate should be matched with the
valve for 100% opening.
3. It is possible to use CONT (the steady state controller) model in FF (Feed Forward) mode to set
valve position. This enables the program to calculate the desired valve position by a simple
algorithm.
4. Another technique is to directly determine the valve position by a signal from PID controller. The
elements found in the next picture form a typical simple control loop. In the technique presented,
the RAMP model generates the current values of the set point. Let’s study the relationship between
the control valve and the PID controller.
CC-DCOLUMN uses cross-linking to define the relationship. In the control valve dialog box, you should
define the controller ID number, and in the PID controller dialog box you should specify the ID number of
the control valve.
This is a portion of the control valve dialog box:
For instance, the control loop can be organized similar to this one:
136
CC-DYNAMICS Version 5.5 User’s Guide
Note:
CC-DCOLUMN uses a signal expressed in milliamperes to transfer information between elements of a
control loop. The default range is 4 – 20 mA. The user can modify this by selecting signal expressed in
volts, in range of –10 – +10 V for example. In such case, the user should be sure to recalculate the
parameters correctly.
The maximum control signal refers to a totally open valve, only in cases where the valve has been
defined as NC (Normally Closed). NC valve is the default valve type in CC-DCOLUMN. To redefine a
valve as Normally Opened (NO), it is necessary to enter different values for the Av and Bv parameters of
the valve. If the 4 –20 mA signal range is used, then these parameters should take values of Av = -
0.0625 and Bv = 1.25. In this case, the maximum control signal refers to a totally closed valve.
The Control valve has several special parameters. These are:
If the downstream is going to pressurized equipment, and the program is to calculate the actual pressure
of this unit, use downstream specification (Destination ID). In this case, the downstream pressure
specification refers to the initial value only. However, in this case it is required to specify initial
downstream pressure.
The static head is a similar additive variable, and it can be constant or variable (when modified by a FF
controller).
The next picture displays signals taken from the above example loop. It is apparent that an equal
percentage NC valve has been used (as the signal grows, then the opening grows; this valve never
closes completely.)
137
User’s Guide CC-DYNAMICS Version 5.5
The control signal and valve position for NO linear valve follow:
It must be pointed out that applying a Normally Opened valve requires re-defining the PID controller
parameters as well. It will be described in the section “How to specify error function”.
138
CC-DYNAMICS Version 5.5 User’s Guide
139
User’s Guide CC-DYNAMICS Version 5.5
140
CC-DYNAMICS Version 5.5 User’s Guide
The structure of the loop using CC-DCOLUMN models is a little bit different:
We would like to point out that the transmitter (or sensor) is a part of the CC-DCOLUMN PID controller
module and the CC-DCOLUMN control valve is a part of the process. Any change in the setting of these
units will require tuning of parameters of the PID algorithm. We have already discussed the control valve
settings. The specification of the transmitter is related to the specification of the PID parameters in the
PIDC model. From now on we will use the word “transmitter” and not the word “sensor” here, because
we will be concentrating on the 4 – 20 mA signal produced by transmitter. The working method of a
sensor is not important from this standpoint.
You need to understand how the parameters of a transmitter in the PIDC dialog box should be specified.
The measured variable definition and the range of the measured variable are involved. If problems in
operation of any control loop occur, then we recommend inspecting the range definition first.
Notes: Any modification of range will influence the sensitivity of the controller, so tuning the PID
parameters will be necessary. Apply the quadratic type equation for mass flow rate control, and the
linear equation otherwise.
141
User’s Guide CC-DYNAMICS Version 5.5
The control error is defined as the difference between the current value of the measured variable and the
desired value (the set point). The desired value can be either a constant or a time dependant variable.
A graphical explanation of the error function is given below:
So, if the measured variable increases and the process response increases, then the error function is
defined as the difference between the set point and the measured value (definition 1); If measured value
increases and the process response decreases, then the error function is defined as the difference
between the measured value and the set point (definition 2).
Note: The error function is calculated in milliamps (or volts).
142
CC-DYNAMICS Version 5.5 User’s Guide
Examples:
Assume you are measuring the temperature at the process outlet of a heat exchanger and regulating
that temperature by controlling the heating agent flow rate at the utility inlet, and the control output is to
close the NC valve causing the measured temperature to decrease (the answer decreases), then you
should apply definition (1).
Assume you are regulating the liquid level in a vessel by controlling the liquid outflow from the bottom of
the vessel. The control valve is located at the liquid outflow stream, and you measure the liquid level in
the vessel. If the NC valve opens (control output increases), then the measured variable (the level as
the process answer) decreases. Your error definition should be (2).
Now, you would like to control the level in the vessel, but you prefer to locate the valve at the feed inlet to
the vessel; the NC valve opens (control output increases) and the measured variable (the level as the
process answer) increases too. You would apply definition (1).
TI is the integral time constant in minutes (the time unit is minutes in the dynamic simulation)
calculate the D term as:
100 d(error )
D= ∗ Td ∗
PB dt
Td is the derivative time constant in minutes.
calculate the control output signal as
143
User’s Guide CC-DYNAMICS Version 5.5
Coutput = P + I + D + C0output
C 0output is the output at steady state, calculated at the initialization of the simulation.
- in the equations above P,I,D and the calculated control outputs have mA as the unit of measure
Example: calculations for a P I (proportional, integral) controller:
Control valve is NC, linear, range 4 – 20 mA
Transmitter of measured temperature is linear, range 20 – 80 C : 4 – 20 mA
10 % opening on the control valve decreases the temperature by 1.5 °C
What is the value of PB?
The controller output is 66% at the steady state working point (at the set point for example)
If the current temperature is higher than the set point by 0.1 °C, then
- what is the new control output, and
- what is the new valve position?
Solution:
If the current temperature readout is higher than the set point by 0.1 C, then
Error = (MV – SP) = 0.1 * (20 – 4) / (80 –20) = 0.0267 mA
The current control output (with simplified I-term calculation) is:
144
CC-DYNAMICS Version 5.5 User’s Guide
- If you experience oscillation during the simulation then increase the time constant
Guidelines for advanced parameter tuning can be found in handbooks for control engineers. It must be
pointed out that a simulation performed in steady state can help you find several valuable parameters. It
is also important to run steady state simulations to determine the initial state for the dynamic
calculations.
You can find these parameters in the second tab of the PIDC dialog box. It is important to understand
that CC-DCOLUMN PIDC is a model of an analog controller or, in other words, the model models an
analog valve actuation. This kind of actuator does not keep the valve at its last position, but eventually
moves it to its final position. This final position is fully closed (NC valve) or fully opened (NO valve).
The special options can be used in batch or semi-batch technologies. If a controller goes into the limited
area or it is out of active time then its output gets the minimal value and it will close or open very quickly.
This working mode can have a lot of benefits but it can also cause oscillation. The use of these
parameters strongly depends on the technology and on the concept of control.
CONTROL STRUCTURES
We have discussed the schematic diagram of an easy control structure. This is the local control loop.
The operators of a process control system should define the set point for any local loop. The set point
can be constant over a period of time, or the operator can modify it from time to time.
Applying a constant set point in dynamic simulation is easy. It is enough to define the set point value in
the dialog box of PID controller model.
145
User’s Guide CC-DYNAMICS Version 5.5
The first rule in CC-DCOLUMN is that the PID controller is a unit operation and it should be connected to
other unit operations with process streams. The second important rule is that the layout of the control
loop should always be carefully analyzed. You have to consider both location of the control valve and
the location of the PID controller.
In most cases, you insert the controller and the control valve into an existing flowsheet. Therefore, you
need to analyze the flowsheet itself. Check for the following points:
- What are the practical rules of control engineering
- Where is the measured variable (is it a stream, or is it a unit operation variable)
- Where is the adjusted point (location of control valve in the flowsheet)
- What unit operations are between the adjusted and measured points
- What is the actual and / or possible calculation sequence
- What is the time step of the dynamic simulation
The selection of location is easy if the controlled variable is the flow rate of a process stream. You just
insert the controller into the appropriate stream and this stream becomes the inlet stream of the
controller. The location of the control valve can be before or after the controller.
146
CC-DYNAMICS Version 5.5 User’s Guide
In all other situations, you should take into account that the measured object is defined in the control
model. Therefore, you are free to locate the controller anywhere in the flowsheet. For practical reasons,
it is the best is to locate controller and control valve together on the same stream. So, under optimal
conditions, you would locate the controller at the stream where the control valve has been placed to
adjust the process.
The intention of the examples of this manual is to demonstrate good schemes for the control systems of
distillation columns. You can follow this logic when you apply more powerful control structures than a
local loop.
In the next example you will see three different solutions for the control of column pressure. All of them
work:
- The locations of the control elements resemble the classical way of thinking in the first solution.
- The second solution follows the logic described above as “use controller and control valve
together in the same stream”.
- In the last solution, we made a little change in the sequence of unit operations, but the solution
handles the calculation sequence (unit 1, unit 2, unit 3, …) much better than two preceding
solutions.
147
User’s Guide CC-DYNAMICS Version 5.5
148
CC-DYNAMICS Version 5.5 User’s Guide
The PIDC model of CC-DCOLUMN includes all parameters needed for a cascade control structure. We
will explain the parameters by example of a typical control solution.
The picture below shows a section of this technology. The objective is to maintain the temperature of a
tray in the bottom section of a distillation column when the concentration of the feed changes.
We have defined a pseudo side stream [14]. This stream has nearly zero mass flowrate but it transfers
the temperature, pressure and concentration data of the tray to this dummy stream. Primary controller
[9] has been inserted into this stream. The measured variable is the temperature of the stream, which is
equal to the tray temperature.
The adjusted variable is the set point of the slave controller [16]. We then manipulate the steam flow
rate of the reboiler [15] by adjusting the slave controller set point.
The CC-DCOLUMN dialog box defines the relationships between the units.
For the primary loop the only special definition is the slave identification:
149
User’s Guide CC-DYNAMICS Version 5.5
For the slave loop, the only special definition is the master or primary loop identification:
The units mutually communicate with analog signal expressed in milliampers. The actual temperature
and mass flowrate profiles can be seen below:
150
CC-DYNAMICS Version 5.5 User’s Guide
The RAMP model has the following parameters in mode 0 (Use the table below):
151
User’s Guide CC-DYNAMICS Version 5.5
Set point control can be achieved by inserting a new unit into the control structure to calculate the real
time set points using online process data. In the manual, we will demonstrate a simple example only.
Advanced users can change the calculator model with Excel unit operation or with special, user-written
calculation algorithms.
This example uses a batch technology. We used the set point controller of the local control loop to
control the reflux flowrate. A pictorial of a section of the technology follows:
152
CC-DYNAMICS Version 5.5 User’s Guide
The reflux ratio versus time profile is given. R-profile (RAMP) model keeps track of the profile and
passes the actual reflux ratio to the SPC model (Set Point Controller), which produces an actual set point
for FC (local flowrate) controller. The red arrows show the direction of information transfer. There is no
information conversion to mA and back in this case.
The setting of RAMP follows:
The SPC model calculates the actual reflux flow rate = set point value as desired, according to the
equation:
R = Rratio * D {Adjusted variable = Scale factor * Measured variable}
where R and D are reflux and distillate flow rates, respectively.
The SPC model reads the real time data of the distillate flow rate; (this is the stream 8), calculates the
real time set point and writes this into the parameter table of the FC model. Eventually, FC controller
(PIDC) modifies the reflux flow rate. It is also possible to calculate on-line value of reflux ratio – see the
trend charts.
The SPC was modeled using the CC-DCOLUMN CONT (Steady State Controller). The data entered
into the dialog box of CONT are:
153
User’s Guide CC-DYNAMICS Version 5.5
Below are several trend charts demonstrating the response of the control system, which appears to be
satisfactory.
154
CC-DYNAMICS Version 5.5 User’s Guide
Using the error chart, we can calculate the maximum error of the reflux flow control. This is 14 kg/h and
the overall difference is 5 kg/h. It is also necessary to point out that the column was under startup
conditions for 30 minutes at total reflux, and the actual reflux ratio profile was activated after startup
finished.
Earlier, we demonstrated that the stream mixer (MIXE) and the stream divider (DIVI) could be applied as
steady state unit operations in dynamic mode. Theoretically, these units do not have any volume or
dynamic properties. They are simulated with simple mass and heat balance equations. The basis of this
philosophy is the fact that the space of the processes of mixing and / or of stream distribution is small.
The residence time and time constant of these unit operations are very small compared to the time step
of dynamic simulation, which is in turn much smaller than time constant of a distillation tower for
example. Therefore, we can neglect the diagnosis of these units. The steady state model of the valve
model (VALV) simulates pressure drop only and it is similar to MIXE and DIVI in this respect. You can
make similar assumptions for liquid pump (PUMP) or for gas compressor / expander (COMP / EXPN).
In many cases, you can accept the simple assumption described above for heat exchanger (HTXR) and
for pipes (PIPE). In such cases, you can neglect the influence of unit’s dynamics on the process
dynamics because it can be in fact small, or because you can assume that the control of temperature
(heat exchanger) is perfect.
Fundamental Rule
Never manipulate intensive variables of a stream directly. Use a one-
sided heat exchanger with outlet temperature definition to set a stream
temperature. Use one of the VALV, PUMP, COMP or EXPN models to
manipulate a stream pressure. Try to use pre-defined streams or
separate component streams combined with mixer or component
separator model for manipulation of concentration. You can combine
these solutions in combination with a RAMP model as well.
Discussed here is a more complicated system using HTXR as a simple temperature setting device. The
example is a separated condenser system for a distillation column. It provides total condensation.
155
User’s Guide CC-DYNAMICS Version 5.5
Solution 1.
Specify the heat transfer area and heat transfer coefficient of unit E1. This is a good approach because
it means using the rating mode for the heat exchanger but the heat transfer coefficient is kept constant.
Solution 2.
Use the "simulation mode" of CC-THERM to re-calculate the value of the heat transfer coefficient. This
is a rating mode also and uses the exchanger geometry to determine the outlet stream conditions.
Both solutions use steady state modules for the heat exchanger.
156
CC-DYNAMICS Version 5.5 User’s Guide
The dashed box covers the dynamic model of the heat exchanger. Each of the stream reference (SREF)
unit operations copies its inlet to its outlet using a scale factor. The scale factor is the time step (unit is
hours) for the inlet points and reciprocal of time step for the outlet points. The shell side at the start of
calculation defines the initial state of the internal recycle stream: flow rate = mass (volume * density), T,
P, and concentration have values of stream Shell_In at time zero. This simple model can take into
account the dynamic properties of the shell side.
To calculate the piping pressure losses between equipment, you normally use the PIPE model. You can
assume that a plug flow model can describe the flow inside a pipe. This assumption results in a well-
defined residence time. If you cannot neglect the effect of this time delay, then you can apply the
following solution.
157
User’s Guide CC-DYNAMICS Version 5.5
Flowsheet
Solution
Tables
Time delay (DLAY) unit operation gets calculated data from the control model.
158
CC-DYNAMICS Version 5.5 User’s Guide
The icons of CHEMCAD unit operations include three different things, these are
- the symbol; this is a visualization of the equipment
- the model; this is mathematical algorithm used for the calculation of that equipment
159
User’s Guide CC-DYNAMICS Version 5.5
- the link; this makes the connection between the symbol and model; in practical terms, the
product of linking is the icon.
According to this concept, you can theoretically use any of CC-DCOLUMN column icons (and their unit
operations) in a dynamic simulation. Practically, it is better to select the specialized Dynamic Column
SCDS icon if your intention is to connect the distillation unit to other unit operations. This is because, not
all icons have enough connection points (inlet / outlet points on the symbol).
Therefore, the following SCDS icon is recommended:
This icon involves built-in control loops and built-in dynamic vessels (both for condenser and/or reboiler
systems).
160
CC-DYNAMICS Version 5.5 User’s Guide
The next icon does not look as attractive, but it can be used as well, as it includes enough connection
points.
You can simulate systems with separated cooling/heating, too. The next picture shows this concept and
a possible solution for a packed batch distillation column.
In special cases you might want to draw your own icon with CHEMCAD’s built-in symbol builder.
161
User’s Guide CC-DYNAMICS Version 5.5
Let’s start studying techniques of dynamic column calculations with a typical distillation problem. Let’s
choose a situation where the feed of a well-working column changes. This job is installed together with
other examples during the installation of the CHEMCAD Suite under \CCDATA\Examples\Dynamics.
Job name is FEEDCHANGEDCOLM. It contains the starting data and information.
The components and thermodynamic calculation methods follow:
COMPONENTS
ID # Name
1 3 Ethane
2 4 Propane
3 5 I-Butane
4 6 N-Butane
5 7 I-Pentane
6 8 N-Pentane
7 10 N-Hexane
8 11 N-Heptane
9 12 N-Octane
THERMODYNAMICS
162
CC-DYNAMICS Version 5.5 User’s Guide
The column is in steady state before the change of feed and it works properly with the following
parameters:
No. of stages 30
1st feed stage 15
Condenser type 1 Partial condenser
Select condenser mode: 1 Specified by reflux ratio
Condenser spec. 3.0000 Rr = R/D
Reboiler mode 3 Specified by bottom temperature
Reboiler spec. 157.0000 T_bottom, C
Top pressure 15.0000 P_top, bar
You can implement the change of feeds with a simple use of RAMP modules with the following
parameters:
--------------------------------------------------------------------
RAMP RAMP
on on
Feed_1 Feed_2 Remarks
--------------------------------------------------------------------
Stream ID 1 2
Variable No. 6 6 Mass flow rate
Variable unit 1 1 Mole / Mass
--------------------------------------------------------------------
Time Value Value
(min) (kg/h) (kg/h)
--------------------------------------------------------------------
0.0 19800.00 1.0000e-06
0.001 1.0000e-06 20000.00
300.000 1.0000e-06 20000.00
--------------------------------------------------------------------
You would calculate the steady state values first. The following picture presents the important data
before the change of feed. This is the initial state of the system.
163
User’s Guide CC-DYNAMICS Version 5.5
It is good to know the final state of the column (or, in other words: to know the answer to the question)
before you start the dynamic simulation. Which parameters should be used for this calculation? If you
keep the original operating parameters, that is, R/D and bottom temperature, then the question is: what
is the capacity of the column?
164
CC-DYNAMICS Version 5.5 User’s Guide
The new feed contains new component concentrations and produces new product streams. From the
standpoint of the required separation, you should check the key components only:
Before ( wt. %) After ( wt. %)
N - Pentane (top) 0.017871 0.000927
I – Butane (bottom) 0.002873 0.010424
The results reflect the change of component concentration in the feed and anticipate enough capacity
but still do not necessarily provide an adequate picture of the column operation. The reason is the
specified simulation parameters are not for column operations. Operating parameters, R/D and bottom
temperature, are typical design parameters for steady state, but more appropriate operating selections
for the initial condition of the column would be the real operating parameters, such as heat duty of
reboiler and heat duty of condenser.
165
User’s Guide CC-DYNAMICS Version 5.5
According to the first steady state calculation these values would be:
Heat duty of condenser 12515.9 MJ/h
Heat duty of reboiler 18942 MJ/h
Now, you can repeat the steady state calculation after the feed change keeping operating parameters as
given above at constant values.
The main streams are now:
Examining the bottom product, you can see that without any modification the column cannot produce
acceptable purity at the bottom anymore; temperature decreased 3.5 C, and the concentration of I-
Butane increased to 0.11 w%.
You can study this behavior of the column using the dynamic column model of CC-DCOLUMN. Select
this option in the “Run / Convergence” sub-menu.
166
CC-DYNAMICS Version 5.5 User’s Guide
In dynamic simulation, you normally do not want to use the condenser and reboiler specifications in the
same way as in steady state. Therefore, we selected bottom mass flow rate and reflux flow rate for the
column specs.
167
User’s Guide CC-DYNAMICS Version 5.5
For the first dynamic simulation use minimal settings. The meaning of “minimal settings” is:
Calculate a continuous process starting from steady state for the initial state.
Ignore the vapor holdup and specify constant liquid holdup in moles; specify all trays the same.
Do not calculate the condenser and reboiler system separately. Use the overall specifications for
distillation column.
Record data of selected trays only and request on-line plotting of product concentration.
The picture below gives an overview of these settings.
For the dynamic simulation, we should specify the time duration of the simulation and the time step size.
168
CC-DYNAMICS Version 5.5 User’s Guide
Typical
start
The following plot gives the I-Butane concentration in the bottom product when the bottom and reflux
streams are kept constant.
169
User’s Guide CC-DYNAMICS Version 5.5
If you return to the original R/D = 3 and T_bottom = 157 °C parameters, and then repeat the dynamic
simulation, you will get information about the operating parameters needed for the condenser and
reboiler.
170
CC-DYNAMICS Version 5.5 User’s Guide
According to the chart, you can tell that good compensation of the noise of the feed requires fast
response of the condenser and reboiler system, and it will result in rapid changes in the flow rate of the
reflux stream. No real control equipment can do this. However, you have been able to determine an
appropriate control strategy. It must be pointed out that this strategy produces an overshoot and a slow,
asymptotic convergence later.
Let’s compare the result of the converged dynamic simulation to the result of the steady state simulation.
These can be found below and reflect a good equivalence to the result of steady state simulation (see
second material balance of the example above). By running the calculation over a longer simulation
period, you would observe smaller differences. Do not expect the results of both types of simulations to
be 100% identical.
171
User’s Guide CC-DYNAMICS Version 5.5
In the next step, we extend the dynamic column to represent a more realistic column. The dynamic
column model can calculate holdup on each tray if the sizing data is given.
This calculation works for tray-columns only. For packed columns, we suggest entering the holdup
profile. In such case, you should estimate the holdups; you can define a different holdup for each
segment of the packed column if you like. This approach can be important when you use the mass
transfer model for the calculation of the vapor-liquid component transfer and the segment sizes are
different.
If you know tray sizes (that is, you are calculating an existing column), then you should enter the
available data.
172
CC-DYNAMICS Version 5.5 User’s Guide
173
User’s Guide CC-DYNAMICS Version 5.5
174
CC-DYNAMICS Version 5.5 User’s Guide
The pressure drop is constant in the dynamic column calculation. The program does not calculate new
pressure drops at each time stop. The "variable pressure" option means a new top pressure is
calculated at each time point. The actual pressure of a tray is calculated from the variable top pressure
and from the interpolated pressure drop based on the tray position and on the total pressure drop. This
calculation can be important for columns equipped with total condensers.
Before you install any control loops around the column, we will make an analysis of the dynamic
properties of the column. Several time dependent cases can be recorded during the simulation if the
“Record process” option of the “Dynamic menu” is selected.
175
User’s Guide CC-DYNAMICS Version 5.5
For example:
CC-DCOLUMN will save a set of case studies automatically according to this table. The case studies
will be given names such as: #D15, #D30, … It is possible to examine individual case studies, normally
after the simulation.
The plot below presents sample temperature profiles taken from saved case studies. The objective is to
understand the sensitivity of the column and to find a “good tray” for the temperature control system. We
decided to select a tray from the area enclosed in the box in the picture. The common property of trays
from 24 to 26 is in the fact that the temperature profiles show an inflection point here. We have selected
tray 24 for measurement and control of temperature for the bottom section of the column.
176
CC-DYNAMICS Version 5.5 User’s Guide
In the control system, we will try to maintain nearly constant temperature of this tray.
Let’s explain the sequence of work for the reboiler system of this example.
Step 1
- Switch simulation mode from dynamic to steady state
- Insert a multipurpose flash module into the stream of B_product (bottom product)
- Connect the vapor outlet of flash to the column, this will be the vaporized stream from the
reboiler
- The original column outlet is the inlet of flash, this stream is coming from the last tray
(segment), its new name is B_liquid
- The liquid outlet of the vessel is the bottom product of the column
- Modify the settings of column: there is no reboiler, so decrease the number of trays by one and
specify the new feed on the last tray
- Estimate the B_liquid stream using the result of last calculation (liquid from tray 29)
- Specify flash with temperature (Tb = 157 °C) and pressure (left it blank)
- Use the recycle run option to converge the loop containing unit 5 and unit 8
Step 2
- Insert a heat exchanger before flash
- Use steam as utility – heating – agent
- Using several options of overall HTXR module and / or using the CC-THERM module of the
CHEMCAD Suite, obtain the size data of the reboiler heat exchanger, finally use rating
definitions (area and heat transfer coefficient)
- Delete specification of vessel
- Use the vessel sizing tool for the flash (keep the column diameter for vessel diameter)
- Run the new system and achieve the converged solution
177
User’s Guide CC-DYNAMICS Version 5.5
178
CC-DYNAMICS Version 5.5 User’s Guide
Step 3
This is the result of the steady state process and this is the initial state of the dynamic simulation.
This sequence follows:
- Swap the flash module with dynamic vessel module and specify it using flash size data or by
existing equipment data
- Insert a liquid level control loop into the B_product stream, use control valve sizing tool or enter
existing data
Specify the controller:
- Run the units in the control loop and check the initial values (transmitter, controller output, valve
position, connection or information transfer between the vessel and control valve)
- Repeat these steps and specify the local flow rate control loop of steam
- Use a cascade control system, let the primary loop be a temperature control on the tray 24
179
User’s Guide CC-DYNAMICS Version 5.5
- Specify an empty side product stream on tray 24 (column model, mass flow rate =1e-6)
- Run and then verify the cascade control system (define the inlet of TC controller before the
calculation; use the data of tray 24; unit numbers for this steady state run are: 12, 9,11,10)
- Use the “Run All” option of steady state simulator and save the result of converged run; this is
the initial state of the system, turn the initial flag of column to mode 1(reload column profile) on
the Convergence screen.
- Switch the simulation mode to dynamic
This is a possible result of steps described above:
Equip. No. 5
Name Bottom vessel
Pressure bar 15.0870
Recorder option: 1 On line recording
Diameter m 2.6000 Equal to the column diameter
Cylinder length m 8.0000 Estimated
Int. liq lev 1 m 3.0000 estimated
Liq flow 1 mode 3 Control valve (link, vessel is active)
Liq flow 1 spec. 8.0000 ID
Equip. No. 6
Name Reboiler Heat exchanger
U W/m2-K 800.0000 Estimated
Area/shell m2 200.0000 Estimated
Controllers
Equip. No. 7 10 12
Name LIC FIC TIC
PB (Proportional Band) 100.0000 100.0000 100.0000
Ti (Integral time, min) 2.0000 0.5000 15.0000
Set point 3.0000 9537.0000 140.4000
Error definition 0 1 1
Control valve ID. 8 11 0
Measured object 1 (Unit) 0 (Stream) 0 (Stream)
Measured object ID. 5 16 18
Measured variable 43 (Level ) 6 (Flowrate) 1 (Temp)
Variable unit 18 (Length) 1 (Mass) 2 (Temp)
Cascade ID 0 0 10
Controller/Sensor Func. 0 (Lin.) 1 (Quadr.) 0 (Lin)
Variable Min 1.0000 5000.0000 120.0000
Variable Max 5.0000 15000.0000 160.0000
Ctrl input min 4.0000 4.0000 4.0000
Ctrl input max 20.0000 20.0000 20.0000
Primary ID 0 12 0
180
CC-DYNAMICS Version 5.5 User’s Guide
Control valves
Equip. No. 8 11
Name Valve-product Valve-steam
Valve flow coefficient 54.0000 480.0000 Sizing tool
Rangeability 10.0000 10.0000
Critical flow factor 0.9800 0.9800
Downstream pressure bar 14.8000 13.0000 Defined
Controller ID 7 10
Valve time constant 0.1000
Valve Av 0.0625 0.0625 NC valve
Valve Bv -0.2500 -0.2500
Equip. ID 0 9 Transfer to SREF
Equip. var. no 0 11 Fixed flow rate
The modified column specifications are:
Equip. No. 4
Name T1
No. of stages 29 1+28
1st feed stage 15
2nd feed stage 29
Condenser type 1 Partial
Select condenser mode: 1 Reflux ratio is specified
Condenser spec. 3.0000 R/D
Side product stage 24
Side product mode -3 Liquid mass flow rate
Side product spec. 1.0000e-006 Empty stream
Colm press drop bar 0.0870
Top pressure bar 15.0000
Iterations 100
Initial flag 1
Tray type 3 Sieve tray
Column diameter m 2.6000
Tray space m 0.4000
No of sections 2
Diameter 2nd sec. m 2.6000
Section 2 stage no. 15
No of passes (S1) 4
No of passes (S2) 4
Weir side width m 0.2509
Weir center width m 0.2622
Weir off-center m 0.2576
Weir side (2) m 0.3142
Weir center (2) m 0.3737
Weir off-center(2) m 0.3672
Weir height m 0.0508
Weir height (2) m 0.0508
System factor 1.0000
181
User’s Guide CC-DYNAMICS Version 5.5
General Information
182
CC-DYNAMICS Version 5.5 User’s Guide
183
User’s Guide CC-DYNAMICS Version 5.5
Typical trends:
The I-Butane concentration of bottom product is stabilized on a low level of 1250 ppm. The main control
variable – temperature of tray 24 – is stabilized at the set point, this is 140.4 °C. The trend of the reflux
flowrate and the trend of the steam mass flowrate show a well-controlled and stabilized system.
184
CC-DYNAMICS Version 5.5 User’s Guide
Important note: We suggest you attempt to expand the flowsheet for the condenser system. Use a
heat exchanger and a dynamic vessel (isobaric). Use a local flowrate control loop on the cooling water
inlet and a primary loop as liquid level control of the reflux vessel. Use a local loop for the flow rate
control of reflux and try to combine it with tray temperature controller (cascade) or with any SPC
controller. For SPC controller (steady state controller) we recommend the Feed-Forward type algorithm,
which can predict the best set point by information of noise.
185
User’s Guide CC-DYNAMICS Version 5.5
Example:
186
CC-DYNAMICS Version 5.5 User’s Guide
- Modify the column parameters: increase the number of trays to the original specification; DO
NOT SPECIFY UTILITY STREAMS AS FEED OR SIDE PRODUCT; set the reboiler
specification
- Run the whole system and save the converged solution; this is the initial state of the dynamic
simulation
- Switch the dynamic simulation mode on
The new flowsheet at initial state looks similar to this one:
187
User’s Guide CC-DYNAMICS Version 5.5
188
CC-DYNAMICS Version 5.5 User’s Guide
189
User’s Guide CC-DYNAMICS Version 5.5
190
CC-DYNAMICS Version 5.5 User’s Guide
191
User’s Guide CC-DYNAMICS Version 5.5
The trends:
This control system also works well. The dynamic properties of the system differ from the first solution;
simple copying of original parameters is not sufficient. The same trends would probably be produced if
tuning of the parameters of each control loop were performed.
Special Note: This column works with a partial condenser. Do not use the built-in reflux control system for
a partial condenser system.
The next example explains usage of multipurpose dynamic column model for a column equipped with
total condenser.
HOW TO USE DYNAMIC COLUMN MODEL FOR CONTROL OF CONDENSER AND REFLUX
The job files for this example are installed automatically during the installation of CHEMCAD under
CCDATA\Examples\Dynamics. The name of the job is DCOLM_CONT. The installed job is not identical
to the example we describe but can be customized for following example.
192
CC-DYNAMICS Version 5.5 User’s Guide
In this example, the second typical method of dynamic studies is described. This is an analysis of
dynamic properties of a closed-loop control system by change of set points. The technology is a
continuous process and the study starts from a steady state condition with change of set point.
Our main objective here is to highlight the details of the calculation method for the total condenser
system, the reflux flow control and the column pressure control. The same technique for the reboiler
system as described in the first detailed example has been applied. The component system and the set
of thermodynamic methods follow:
COMPONENTS
ID # Name
1 117 Methanol
2 140 Acetone
3 134 Ethanol
4 62 Water
THERMODYNAMICS
Feed streams:
Stream Name Feed_1 Feed_2 Feed_3
Temp F 150.3300* 160.3300* 130.3300*
Pres mmHg 760.0000* 760.0000* 1250.0000*
Enth Btu/h -3.6452E+007 -1.4774E+009 -6.2616E+008
Vapor mole fraction 0.00000 0.00000 0.00000
Total lbmol/h 300.0000 12195.0000 6000.0000
Total lb/h 5404.5000 229521.4688 231309.0000
Total std L ft3/hr 86.5857 3742.7737 4613.1787
Total std V scfh 113843.59 4627742.00 2276871.75
Component mass %
Methanol 0.000000 0.209405 54.024619
Acetone 0.000000 0.759145 37.663904
Ethanol 0.000000 6.021528 5.974995
Water 99.999994 93.009925 2.336485
Utility streams:
Stream Name CW inlet Steam
Temp F 80.3300* 266.5000*
Pres mmHg 2000.0000* 2040.7342
Enth Btu/h -8.4718E+009 -4.4650E+008
Vapor mole fraction 0.00000 1.0000*
Total lbmol/h 69007.7969 4356.0000
Total lb/h 1243175.3750 78473.3359
193
User’s Guide CC-DYNAMICS Version 5.5
The steady state calculation reports the converged solution of the column, and this is the initial state of
the process. The figures below show the flowsheet and the mass balance. We have marked important
parts of the control system in the flowsheet:
- Total condenser system
- Pressure control
- Liquid level control of reflux drum
- Reflux flow rate control
Flowsheet and calculated stream data at initial state.
194
CC-DYNAMICS Version 5.5 User’s Guide
195
User’s Guide CC-DYNAMICS Version 5.5
In the plot of the column temperature profile, we point to the new set point, which is 10 F above the
current temperature. The temperature control loop is the primary loop of the steam flow rate control. For
the much faster response of the cascade controllers, we also increased the set point of the flow rate
control loop. All other controllers keep the existing set point.
The unit parameters (first part: external controllers and control valves).
Controllers
Equip. No. 7 5 12
Controller Name LC-B_level FC-Steam TC-Tray_45
PB (Proportional Band) 200.0000 666.7000 200.0000
Ti (Integral time, min) 5.0000 0.2500 17.0000
P0 Steady state output 9.3843 15.2533 7.2400
Set point 8.0000 81000.0000 180.3300 <- NEW SP
Error definition 0 1 1
Control valve ID. 6 4 0
Measured object 1 0 0
196
CC-DYNAMICS Version 5.5 User’s Guide
Controllers
Equip. No. 10 3
Controller Name LC-C_vessel PC-Column
PB (Proportional Band) 90.9000 66.7000
Ti (Integral time, min) 3.0000 3.0000
P0 Steady state output 10.3529 11.5918
Set point 3.0000 760.0000
Control valve ID. 9 2
Measured object 1 1
Measured object ID. 1 (Unit) 1 (Unit)
Measured variable 136 (level) 34 (pressure)
Variable unit 18 (length) 4 (pressure)
State 1 1
Variable Min 1.0000e-004 500.0000
Variable Max 10.0000 1000.0000
Ctrl input min 4.0000 4.0000
Ctrl input max 20.0000 20.0000
Control valves
Equip. No. 6 4 9 2
Equip. Name B_V S_V D_V W_V
Valve flow coefficient 665.0000 2150.0000 120.5000 1720.0000
Rangeability 10.0000 10.0000 10.0000 10.0000
Critical flow factor 0.9800 0.9800 0.9800 0.9800
Downstr. pres.,mmHg 1200.0000 886.0500 800.0000 780.0000
Calc. flow rate lb/h 391536.0625 78473.3359 74698.8672 1.2432e+006
<-actual ->
Controller ID 7 5 10 3
Valve position % 33.6519 70.3329 39.7056 47.4490
Valve time constant 0.1500 0.2000 0.1500 0.1500
Valve Av 0.0625 0.0625 0.0625 0.0625
Valve Bv -0.2500 -0.2500 -0.2500 -0.2500
Controller output 9.3843 15.2533 10.3529 11.5918
Steady state position 33.6519 70.3329 39.7056 47.4490
Controller output SS 9.3843 15.2533 10.3529 11.5918
197
User’s Guide CC-DYNAMICS Version 5.5
Destination ID 0 1 0 0
Var. No. 0 144 0 0
Phase option 1 0 1 1
Equip. ID 0 13 0 11
Equip. var. no 0 11 0 11
The setting of the dynamic column model (second part: units included into column model).
198
CC-DYNAMICS Version 5.5 User’s Guide
199
User’s Guide CC-DYNAMICS Version 5.5
200
CC-DYNAMICS Version 5.5 User’s Guide
Reflux control valve and controller specification (identical with the normal specification).
201
User’s Guide CC-DYNAMICS Version 5.5
The reboiler specification involves a heat exchanger and a dynamic vessel. You should define here the
ID of the control valve for level controller (active unit in the flow rate transfer) and the initial value of level.
202
CC-DYNAMICS Version 5.5 User’s Guide
203
User’s Guide CC-DYNAMICS Version 5.5
204
CC-DYNAMICS Version 5.5 User’s Guide
The simulation results indicate a good-working control system. The temperature of tray 45 has been
stabilized at the new set point and other controlled variables are at practically steady state values as
well. From an operating standpoint, the bottom section of the column works at a higher temperature and
we have acetone at a lower concentration in the bottom product, that is, under 0.1 wt %. (The starting
value was higher than 5 wt %.)
205
User’s Guide CC-DYNAMICS Version 5.5
Flowsheet:
Balance
206
CC-DYNAMICS Version 5.5 User’s Guide
The column profiles after 300 minutes dynamic simulation show significant differences to the initial state
in the bottom section of the column.
This problem is typical. A component should be recovered from a mixture. This mixture is strongly non-
ideal and contains components in very different concentrations. Considering the volume of the raw
material and the properties of mixture, it was decided that batch distillation unit would be suitable.
The job was initially studied with the CC-BATCH module to estimate several operating parameters.
Batch distillation technology is not limited to a distillation column but it also involves several auxiliary
equipment pieces: heat exchangers for vaporization of liquid mixture and for condensation of vapor;
vessels to accumulate the distillation products; pumps and several devices of control system.
207
User’s Guide CC-DYNAMICS Version 5.5
The parts of the control system are circled. The T1 column is modeled with CC-DCOLUMN.
Each charge needs same operating steps:
- startup of the system
- continuous regime under controlled parameters
- shutdown of the production
The multifunctional unit of CC-DCOLUMN is able to simulate this technology using built-in models. For
practical reasons, we split the system into independent equipment pieces, and we used the SCDS model
for the distillation column only. We will explain the analogy between this detailed solution and the
universal model description of SCDS later.
208
CC-DYNAMICS Version 5.5 User’s Guide
209
User’s Guide CC-DYNAMICS Version 5.5
Notes:
1. The jacket pressure controls the steam feed flow rate automatically. This mechanism can be
defined in this way:
2. The reboiler has been defined as discrete unit operation, the batch reactor. The following picture
shows analogy between the definition of the built-in reboiler of the CC-DCOLUMN model (top), and
similar definition of reboiler made of separate batch reactor (bottom):
210
CC-DYNAMICS Version 5.5 User’s Guide
3. There is a similar analogy between built-in units of CC-DCOLUMN (such as the accumulator, the
condenser, and the reflux control loop), and similar units made of discrete unit operations. A
summary of the existing unit operations follows:
211
User’s Guide CC-DYNAMICS Version 5.5
Vessels:
Equip. No. 3 5
Equip. Name D2 D3
Pressure bar 10.2000 10.0000
Recorder option: 1 1 Record history
Diameter m 0.6000 1.4000
Cylinder length m 1.8000 2.0000
Head type: 3 3
Int. liq lev 1 m 1.0000e-010 1.0000e-010 Empty vessels at start
Liq flow 1 mode 3 0
Liq flow 1 spec. 8.0000 Controlled by CVAL 8
Control Valves:
Equip. No. 10 8
Equip. Name V2 V3
Valve flow coefficient 9.0000 9.0000
Rangeability 10.0000 10.0000
Valve type 1 1
Critical flow factor 0.9800 0.9800
Downstream pressure, bar 10.2000 10.4000
Controller ID 9 7
Valve time constant 0.1000
Valve Av 0.0625 0.0625
Valve Bv -0.2500 -0.2500
Phase option 1 1
Equip. ID 4 0 Flow rate transfer
Equip. var. no 3 0
PID Controllers:
Equip. No. 9 7
Equip. Name FC LC
PB (Proportional Band) 125.0000 25.0000
Ti (Integral time, min) 0.5000 5.0000
P0 Steady state output 4.0000 4.0000
Set point 1.0000e-006 0.9000 Controlled by SPC
Error definition 1 0
Control valve ID. 10 8
Measured object 0 1
Measured object ID. 7 3
Measured variable 6 43
Variable unit 1 18
State 1 1
Controller/Sensor Func. 1 0
Variable Min 1.0000e-006 1.0000e-006
Variable Max 1500.0000 2.0000
Ctrl input min 4.0000 4.0000
Ctrl input max 20.0000 20.0000
212
CC-DYNAMICS Version 5.5 User’s Guide
Heat Exchanger:
Equip. No. 17
Equip. Name E1
U kcal/h-m2-C 400.0000
Area/shell m2 4.0000
Elements of SPC calculation:
RAMP
Equip. No. 15
Equip. Name R-profile
Equip/Stream ID 16 CONT module
Varaible No. 9 Scale
0.999 time & value
90.0 0.999
120.0 0.8500
300.0 0.8500
CONT
Equip. No. 16
Equip. Name SPC
Mode 1 FF
Equip. no. adjusted 9 Reflux controller
Variable No. 6 Set point
Measured variables:
Number 21 Liquid stream from condenser
Variable 6 Mass flow rate
Scale 1.0000 Defined by RAMP module
213
User’s Guide CC-DYNAMICS Version 5.5
The parameters that have been entered as specifications of the distillation column are:
Plots:
Several plots can be produced using the simulator of batch technology. These can help in the design
phase and can help analyze the existing technology.
With the next set of profiles, we would like to show how you could use these results in the design of time
schedule of the batch technology.
214
CC-DYNAMICS Version 5.5 User’s Guide
215
User’s Guide CC-DYNAMICS Version 5.5
RATE REGRESSION
The rate regression utility in CC-ReACS allows you to regress kinetic data into reaction rate parameters.
The program can handle simultaneous reactions, and many types of data from multiple sources of batch
reactor data. Depending on the data, any coefficients from the Arrhenius or Langmuir-Hinshelwood
equations can be regressed using this utility.
The discussion of rate regression is organized into three parts. In the “Input Discussion”, we will define
all the terms and default values necessary for this package. In “Using Rate Regression” we will step
through how to use the regression tool. In the final section, “Examples” we will look at an example of
using rate regression.
In order to regress kinetic data, you must first define the components, reactions, and reactor vessel used
to collect the rate data. This is done by creating a batch reactor simulation which is capable of
simulating the experiments used to gather the rate data.
216
CC-DYNAMICS Version 5.5 User’s Guide
INPUT DISCUSSION
Rate Regression is an option under the Tools option of the menu bar. After selecting this option, the
Reaction Rate Regression Menu will appear as shown below:
217
User’s Guide CC-DYNAMICS Version 5.5
This dialog box allows you to select which parameters you wish to regress and how many data sets are
to be imported. It consists of two pages. On page one, define the parameters, which will be regressed.
Each parameter has a single row for this. All values in a given row refer to a single parameter. Page
two of this screen has a series of global definitions, which refer to the regression as a whole. Both
pages are shown below:
218
CC-DYNAMICS Version 5.5 User’s Guide
Par Type:
Reaction rates can be computed using either the Arrhenius or the Langmuir-Hishelwood forms of the
rate expression. These equations are described in detail in the Batch Reactor Model section of this
user’s guide. Refer to that section as necessary. The following discussion assumes the user is familiar
with these equations.
• The rate regression program can calculate the following parameters for both the Arrhenius
equation and the Langmuir-Hishelwood equations:
a. The frequency factor, A (RXN-A on the screen).
b. The activation energy, E (RXN-E on the screen).
c. The order of the reaction in each component, which is the exponent of the component
concentration term. (Exp on the screen).
• For the Langmuir-Hishelwood equation only:
a. The adsorption frequency factor, ø (Ad-A on the screen)
b. Component adsorption activation energy, E (Ad-E on the screen).
The Langmuir power factor, β, must be defined by the user if Langmuir-Hinshelwood adsorption
parameters are to be calculated.
Note: Parameters for a user added equation can also be required using this facility. The concepts,
however, are more complex and difficult and are therefore addressed elsewhere.
Tip: Specify none in Par Type to allow a reaction to use a constant Frequency Factor
during regression. If you hold one or two frequency factors constant, regression of the
third will quickly produce a decent estimate for the constant. Once you have reliable
estimates for all frequency factors, you may hold one or two constant to allow for fine-
tuning of the regression.
RXN:
The reaction number of the parameter to be regressed. This is required for all regression parameters.
COMP:
This is the component number for parameters which are component specific (such as e, Ad_A, Ad_E).
This is the position of the component in the stream list, NOT THE COMPONENT ID NUMBER. If you
press the F5 key, the component list will be displayed with both the position number (to the far left) and
the ID numbers (in parenthesis).
Estimation:
This is the initial estimate for the parameter value. An estimate is not required. However, because of
the extreme sensitivity of reaction rate to activation energy, it is strongly suggested that you provide an
initial estimate when calculating E.
219
User’s Guide CC-DYNAMICS Version 5.5
220
CC-DYNAMICS Version 5.5 User’s Guide
Integration method:
The Runga-Kutta 4 (Fast Calculation) is extremely fast and accurate for many, if not most, reaction
systems. However, it cannot be used for stiff systems. The semi-implicit RK4 should be used for very
stiff systems.
Number of Attempts:
Each reset starts with an initial estimate that is an order of magnitude larger or smaller than the last.
-4
Therefore, if the specified (or shown) initial estimate is 10 and the number of attempts is 5; then the
-2 -3 -
program will make five regressions. The five regressions will start with the initial estimates 10 , 10 , 10
4 -5 -6
, 10 , and 10 . The regression producing the best results will be selected by the program as the
preferred answer.
IMPORT PROFILE
The Import Rate File dialog box is used for importing raw data to be regressed. Fields are provided for
file management and for specifying the format and engineering units used by the file. One of these
dialog boxes must be completed for each file to be imported. When the dialog box is closed, the data is
imported.
The dialog box looks like this:
PARAMETER DEFINITIONS
221
User’s Guide CC-DYNAMICS Version 5.5
Data set #:
This input box is used to specify the number of the data set.
Read from line to line :
This tells the program where the data set to be imported begins and ends in the text file.
Time column #:
Enter which column time data is stored in the import file. To the right, enter in the units for this quantity.
Temperature column #:
Enter the Temperature column for the import file. To the right, enter in he units for this quantity.
H of reaction column #:
Enter the column that contains heat of reaction data in the import file. To the right, enter in the units for
this quantity.
Volume column #:
Enter the column that contains volume data in the import file. To the right, enter in the units for this
quantity.
Composition column #:
Enter here the first column that contains composition (concentration or quantity) data. Immediately
following this column should be the concentration or amount of each component in its own column, in the
sequence order of the component list. To the right, enter in the units for this quantity.
Time unit in source file:
Identify the time units used by the file to be imported. Select from the list.
Temp. unit in source file:
Identify the temperature units used by the file to be imported. Select from the list. Used only when the
Temperature column # field has an entry.
Q unit in source file:
Identify the enthalpy units used by the file to be imported. Select from the list. Used only the H of
reaction colm # field has an entry.
V unit in source file:
Identify the volume units used by the file to be imported. Select from the list. Used only when the
Volume column # field has an entry.
Composition unit:
Identify the concentration units used by the file to be imported. Select from the list. Used only
when the Composition col. # field has an entry.
This option is used to inspect input, and/or edit the data to be used in the regression analysis. If data
has already been imported, it will be displayed upon entry into the dialog box. It can then be modified,
extended, or abbreviated as desired. If no data has been imported, the dialog box will be empty.
The Input/Edit Rate Profile dialog box will not open unless a data set filename has been provided on
Page 2 of the Select Parameters dialog box.
222
CC-DYNAMICS Version 5.5 User’s Guide
The dimensions of this dialog box will be (the number of components plus six) by 300.
A column is provided for each of the following:
• Component concentrations
• Weight factor
• Time
• Temperature
• Instantaneous heat of reaction (Qr)
• Volume
• Cumulative heat of reaction (Cum_Qr)
Up to 300 times can be reported. One now is provided for each time.
The Input/Edit Rate Profile dialog box will appear as follows:
PARAMETER DEFINITION
Weight Factor:
This column is used if you wish to fit closer to some data points than to others. If all weights are equal or
zero, all points are equally important in the regression.
Time:
Time at which the data was measured.
223
User’s Guide CC-DYNAMICS Version 5.5
Temperature:
Temperature of reactor.
Concentration:
The concentration of each component is listed in the next set of columns. Concentration units are
selected in the “Select Parameters” screen, second page.
Qr:
Enter the instantaneous heat of reaction here.
Volume:
Enter the reactor volume here.
Cum_Qr:
Enter the cumulative heat of reaction here.
This option is used to check you initial estimates entered in the “Select Parameters” section of the rate
regression utility. In any equation with exponential terms, such as a rate equation, regression of
coefficients is very sensitive to the starting estimation. This utility allows you to check your estimation by
graphing the results of running your batch reactor with these values. This utility should be used to
ensure that your estimates make sense.
PERFORM REGRESSION
Selection of this option initiates the regression calculations. An example of the results from the ARC1
example is shown below.
PLOT RESULTS
This option will plot both the regressed results and the experimental data, allowing you to judge the fit.
An example fit is shown below:
224
CC-DYNAMICS Version 5.5 User’s Guide
Now we are ready to walk through the program. The best way to use the rate regression utility is to do
the following in order:
1. Build a flowsheet representing the experiments or operating equipment used to gather the data.
2. Specify the initial charge of the experiment or batch run from which the data was taken.
3. Specify the general parameters of the regression.
4. Specify the reaction mechanisms in the Reaction Kinetics dialog box(s) of the batch reactor.
5. Call the Rate Regression menu.
6. Select the parameters to be calculated by the regression analysis using the SELECT
PARAMETERS dialog box.
7. Build the regression data sets by importing, entering, and/or editing the raw data.
8. Specify which data sets are to be used in the regression analysis.
9. Check the initial estimates (optional).
10. Perform the regression.
11. Plot the results.
225
User’s Guide CC-DYNAMICS Version 5.5
DETERMINING CONSTANTS
The following parameters from any reaction may be selected for regression:
Reaction frequency factor (A or Aj below)
Reaction activation energy (E or Ej below)
Component exponent (e or akj below)
Component adsorption frequency factor (Ad_A or φ k j below)
−β j
nrx nj nj
−E j /(RT) ak, j −Ek, j /(RT) bk, j
ri =∑ Νi, j ⋅ Α j ⋅ e ⋅ ∏
k =1
Ck ⋅ 1+ ∑
k =1
φ k, j ⋅ e ⋅ Ck
j=1
Note: These parameters may also be regressed in a user added rate expression.
PARAMETER SELECTION
Enter the parameter type, reaction number, and component number (if e, Ad_A, or Ad_E) along with any
bounds and initial estimates you wish. On the next page, name your data files and enter any additional
information such as maximum iterations, error tolerances and K-value settings.
The first step is to build a flowsheet, which represents the process from which the data was gathered.
This normally is just a simple batch reactor (batch process) or a batch reactor with a feed (semi-batch
process).
This flowsheet is drawn like any flowsheet.
There are two ways to specify the initial charge of the experiment:
1. Enter it in the INITIAL CHARGE dialog box of the batch reactor.
2. Include it in one of the import data files as the composition at time zero.
The second option can only be used with files containing concentration data. Where concentration data
files are not present the initial charge can only be given through the INITIAL CHARGE dialog box.
Time zero information in the import data files will override information given in the INITIAL CHARGE
dialog box, if there is a conflict.
226
CC-DYNAMICS Version 5.5 User’s Guide
If the import files provide all necessary information, it is not necessary to complete the INITIAL
CHARGE dialog box.
The following items on the GENERAL INFORMATION dialog box must be entered:
1. Number of reactions
2. Batch time
3. Thermal mode
4. Pressure
The number of reactions must be entered so that the program knows how much data to collect. This is
the case in simulation calculations as well.
The batch time must be entered, but will be overridden if in conflict with the times given in the import
files.
The thermal mode must be identified. Only adiabatic and isothermal can be used in regression mode.
The pressure must be specified when performing regression calculations.
The reaction scheme to be used in the regression analysis must be specified by the user. This is done
in the REACTION KINETICS dialog box of the batch reactor models. The input for this dialog box is
described in the Batch Reactor section of this user guide. The user is referred to this description for
input details.
The following should be noted regarding a regression analysis:
1. The rate parameters to be calculated by the regression analysis should not be entered.
2. If the reaction order is not specified and not calculated, it is assumed to be one for each reactant.
227
User’s Guide CC-DYNAMICS Version 5.5
A regression data set is a collection of various kinds of experimental data from a single file. For
example, if an experiment was run where the temperature was measured and recorded into a file called
TEMP.EX1 and the concentrations were measured and recorded into a file called CONC.EX1, then both
of these files can be imported and saved into a single file or data set. This data set is saved and can be
used in future regressions as desired.
Data sets are built using the IMPORT RATE FILE dialog box and/or the INPUT/EDIT RATE PROFILE
dialog box. The use of the dialog boxes was described earlier in this section and is not repeated here.
The following rules should be remembered when building and using data sets:
1. All data within a data set must come from the same experiment. This is because the program will
apply the same initial and operating conditions to all data contained in a data set.
2. The times for the measurements must be the same for all files collected into a given data set.
3. More than one data set can be included in a regression analysis.
4. Data set file names must be entered on Page 2 of the SELECT PARAMETERS dialog box before
data can be imported or typed into them.
5. The default location for storing data sets is the current job subdirectory.
Therefore, to build a data set:
1. Enter the file name, where the data set is to be stored, in one of the fields provided on Page 2 of the
SELECT PARAMETERS dialog box.
228
CC-DYNAMICS Version 5.5 User’s Guide
2. Import any available files (if any) into the data set using the IMPORT RATE FILE dialog box. One
Source file is imported at a time. The Output file name entered in this dialog box is the data set file
name and will be the same for all source files imported into this data set. (Optional)
3. Edit the import data and/or enter new data using the INPUT/EDIT RATE PROFILE dialog box.
Up to five Data sets can be included in a single regression analysis. These data sets can contain
different information from the same experiment and/or data from different experiments (whether it
overlaps the first data set or not).
The data sets to be included in the regression analysis must be specified on Page 2 of the SELECT
PARAMETERS dialog box in the fields provided under the heading, Specify file name for each data
set: If the data set contains concentration data, the concentration engineering units must be identified in
the field provided. The mode (adiabatic and non-adiabatic) of the regression must always be specified.
This step is optional but generally a good idea. The initial estimates are entered in the SELECT
PARAMETERS dialog box. When the option check initial estimations is selected from the Rate
Regression Menu, the program:
1. Reads the initial estimates
2. Simulates the chemistry using these estimates
3. Compares the simulated results to the experimental data by displaying a series of plots.
To perform the regression, click on the Perform Regression option on the Rate Regression Menu.
During the calculations the program will display the current error in the lower left-hand corner of the
CHEMCAD Window. When the regression calculations are complete, the results will be displayed in a
Wordpad document.
Before returning to the Rate Regression Menu, CC-ReACS will ask if you want to save the calculated
parameters. Answering, “Yes” will cause them to be saved in the batch reactor dialog boxes.
TROUBLESHOOTING REGRESSIONS
Regressing reaction rates can be difficult. If you start having problems with the regression convergence,
try to run the actual simulation from time 0 with some estimation of the reaction rate parameters. By
running these manually you can get a feel for what an acceptable range is for the frequency factor, etc.
It is quite common to make engineering unit mistakes with reaction rates. Usually the problem is
comparing the results in CHEMCAD to available scientific literature. When doing so, always make sure
the reaction rate units are the same.
229
User’s Guide CC-DYNAMICS Version 5.5
CC-ReACS regresses for a fit to the Cumulative Qr rather than the instantaneous Qr (∆Qr/∆t). This is
done for numerical methods reason.
The short explanation of why CC-ReACS uses this method is “CC-ReACS uses this method so the
answer can be found without knowing the answer.”
The difficulty with this method (cumulative Qr) occurs if there is a sharp drop in (∆Qr/∆t) for a single time
step. Regressed parameters that predict a ‘not as sharp drop’ across several time steps will result in the
same cumulative Qr. Numerical integration is simply solving for area under the curve and predicting a
curve that matches the area. The area under a wide and short square is equal to the area under a thin
and tall rectangle. Adding a few data points will force the regression to use a taller rectangle. Using a
smaller time step (AFTER obtaining a decent fit) will also help produce a more accurate fit. If the time
step is smaller, the Cumulative Qr will be more sensitive to the sudden spike of the instantaneous Qr.
The quality of the fit obtained by the regression analysis can be evaluated by plotting the predicted
results and experimental data together for comparison. Clicking the Plot Results option on the Rate
Regression Menu will do this. Five plots will be plotted for each data set.
EXAMPLES
Now we are ready to walk through an example of rate regression. The following example is based on
the reaction of water and acetic anhydride to form acetic acid.
Problem statement: 1.022 kg of Water is charged into a Calorimeter. The Calorimeter is brought to 37.8
C and 152 g of acetic anhydride is injected over the course of 1 hour. Determine a reaction rate
constant such that:
If we take the standard Arrhenius form and set all the langmuir-hinshelwood terms to 0, and set the
exponential factor for acetic acid to 1, the rate expression becomes
(-E/RT)
R=A * CAcetic Anhydride*e
230
CC-DYNAMICS Version 5.5 User’s Guide
Rearranging,
Its clear if we set the Activation Energy (E) to 0, the frequency factor term becomes our reaction rate
constant K. R is the rate or reaction in 1/s, to get to the rate of formation of acetic acid we have to
multiply by the stoiciometric coefficient.
This example is stored in the Examples\Rate Regression folder in your work directory. To work through
the tutorial on your own, you will need to make a copy of the raw RC1 data files. To do this, create a
new simulation and copy the files B1.DAT, QRMINQB1.DAT, TR1.DAT from Examples/Rate Regression
into your new simulation folder.
1. Flowsheet drawing
Build a flowsheet with a batch reactor and a feed stream to represent the dosing.
Define the component list to contain acetic anhydride, water, and acetic acid.
2. Thermodynamics.
This model uses UNIFAC as K model. The enthalpy model selected is Latent Heat. Since the
reaction is isothermal, there will be no heat flux from non-ideal deviation terms with Latent
Heat. You can select this model in the ThermoPhysical menu.
ThermoPhysical menu > K values
231
User’s Guide CC-DYNAMICS Version 5.5
232
CC-DYNAMICS Version 5.5 User’s Guide
233
User’s Guide CC-DYNAMICS Version 5.5
Select the Semi-Batch tab. Select the dosing stream for Feed Stream 1. Select cumulative
as the Feed option 1. The cumulative option indicates that the specified flowrate for the
stream multiplied by one time unit is the total flow from the feed stream.
234
CC-DYNAMICS Version 5.5 User’s Guide
235
User’s Guide CC-DYNAMICS Version 5.5
236
CC-DYNAMICS Version 5.5 User’s Guide
There is only one operation step for this example. Batch time is set to the length of the RC1
data or less. For this example, run time is set at 60 minutes. Step size is set to 0.3 minutes.
13. Importing the RC1 data and performing the Regression.
From the Tools menu select Rate Regression. Select the reactor and press OK. The
Reaction Rate Regression menu will appear.
14. Click on the Select Parameters button.
For an isothermal reaction you can regress the Frequency Factor but not the Activation Energy.
You may also regress the reaction order; but this would complicate the regression for this
example. For a non-isothermal reaction you can regress the activation energy as well as the
frequency factor.
Page 1
Select Rxn_A from the Par Type field, this is the Frequency (Arrhenius) Factor.
Specify the reaction number for the Rxn field. Since reaction 1 is being regressed, type 1.
When you are finished page 1 of the Rate Regression Parameters dialog should look like the
picture below:
Page 2
Specify a file name for CC-ReACS to use as a translated file. This is the file CC-ReACS will
create from the imported RC1 data. Any name you select is OK for the sake of this example.
237
User’s Guide CC-DYNAMICS Version 5.5
For most situations the default values on the numerical methods parameters are sufficient; it is
not necessary to make arbitrary changes without understanding the effect on regression.
238
CC-DYNAMICS Version 5.5 User’s Guide
Press OK and CC-ReACS will convert the RC1 file data to its own format. CC-ReACS will also
enter the dosing schedule to the batch reactor feed schedule for you (you can review it later
on).
16. Check initial estimates (optional).
This allows you to plot experimental values and the values that would be calculated by using
your initial estimates for reaction parameters. If the rates plotted from the initial estimates are
far from the experimental rates for the initial times, you may wish to revise these estimates.
It should be clear that the initial estimates are not the correct parameters, so graphs plotting
reaction rates against experimental data will not match up, but they should trend similarly.
17. Perform Regression.
This will begin the regression will demand most of the computer’s resources; it’s best to leave
your computer alone and have other processes closed when you perform the regression.
Click on the Perform Regression button. Once the regression is finished you will see a report
in WordPad.
CC-ReACS will ask you whether to save the regressed parameters or not. Select the save
regressed parameters option and press OK to review results.
CC-ReACS will show you some plots for you to compare regressed and experimental
parameters.
18. Plot the results (optional).
You may want to review the results and check how the performed regression fits your
experimental data.
239
User’s Guide CC-DYNAMICS Version 5.5
240
CC-DYNAMICS Version 5.5 User’s Guide
Similar to Check Initial Estimates, the Plot Results option allows you to plot the rates
calculated by regressed parameters on the same plot as the experimental rates from the RC1
file.
The whole point of this exercise is to calculate a rate constant given heat release data. The
rate constant CHEMCAD calculates is approx. 0.0176 liter/kmol s. So the rate of reaction is
equal to 0.0176 liter/kmol s * CAcetic Anhydride to get the rate of acetic acid formation, we must
multiply the rate constant by the stoichiometric coefficient of acetic anhydride, 2. So,
241
User’s Guide CC-DYNAMICS Version 5.5
Agitator f a b c
Flat blade disk turbine:
Re<400 0.54 0.67 0.33 0.14
baffled, Re>400 0.74 0.67 0.33 0.14
3 blade propeller:
baffled, 5500<Re<37000 0.64 0.67 0.33 0.14
Anchor:
30 < Re <300 1.00 0.50 0.33 0.14
300 < Re < 5000 0.38 0.67 0.33 0.14
242
CC-DYNAMICS Version 5.5 User’s Guide
OVERVIEW
The Kinetic Reactor dialog box enables the user to specify a custom kinetic rate expression.
BASIC USE
After the user has entered the specifications in the Kinetic Reactor dialog box, the user must input the
kinetic data for each reaction in the system.
243
User’s Guide CC-DYNAMICS Version 5.5
This data is input using the Kinetic Data dialog box. The user is required to enter the stoichiometric
coefficients for each reaction. The frequency factor and activation energy may be entered using this
dialog box if they are used by the kinetic rate expression. The User Rate Expressions dialog box
appears after the Kinetic Data dialog box is closed.
File Paths:
The name of the VBA file and Excel workbook accessed by the simulation must be specified on the User
Rate Expressions dialog box. If the files are not located in the current job folder, the full path will need to
be entered. The file \CC5\userRxns.xls is a template for the User Added Kinetic Rate Expression. This
file should be copied to the current job folder.
244
CC-DYNAMICS Version 5.5 User’s Guide
Rxn I:
Name for the Chemical Reaction:
This name will be displayed on the reports.
Variables for User Rate Expressions:
The following table lists the default parameters available for User Added Kinetic Rate Expression. The
ChemCADEntry VBA object handle can be used to access additional CHEMCAD variables.
FF Frequency Factor The Frequency Factor is specified in the Kinetic Data dialog
box.
ExpERT Exponential Term Calculated as EXP[(E/R)/T]. The activation energy is
specified in the Kinetic Data dialog box. R is the gas
constant.
Temp Temperature The current reactor temperature.
Pres Pressure The current reactor pressure.
RPM Propeller speed The speed of the propeller/mixer. The propeller adds kinetic
energy to the system which is dissipated as heat.
Rvol Total reactor volume The total volume of the reactor. This is either specified by the
user or calculated.
LFrc Liquid vol. Fraction The fraction of the reactor volume that is filled with liquid.
Ci-Cj Component concentration The current concentration of component i.
Pi-Pj Component pressure The current partial pressure.
Additional variables may be dimensioned and specified using VBA standards in the Write User Rate
Expression field.
Write User Rate Expression:
The User Added Kinetic Rate Expression is entered in this field. The expression may consist of a single
line formula, similar to the example given in the dialog box, which uses the pre-defined variables listed in
the Variables for User Rate Expressions field. If the user needs to define additional variables or utilize
a more complex formula, VBA code may be entered into this field. Multiple lines of code may be entered
into this field using the [crtl]+[enter] key combination at the end of each line to insert a line break.
Operators:
This field contains a list of operators that may be used while entering formulas into the Write User Rate
Expression field.
Do you want to update UserRxnRate Module in Excel Workbook:
After completing the User Rate Expression dialog box, a pop-up window prompts the user to save the
changes to the VBA module that contains the code for each User Added Kinetic Rate Expression. The
user should select YES to save the changes, unless Excel is being used to edit the macros manually.
245
User’s Guide CC-DYNAMICS Version 5.5
ADDITIONAL COMMENTS
Multiple Reactors in a Job:
A User Added Kinetic Rate Expression may be used by more than one reactor. Once the first reactor has
been specified, the subsequent reactors are configured to call the same workbook and module. This
feature may also be used with reactors that reside on different flowsheets. For cases where a single rate
expression is used for different simulations, the Excel workbook should be copied into the job folder of
each of the separate flowsheets. This ensures that the rate expression associated with a specific job
does not get lost during export or file transfer.
Kinetic Reaction VBA Macro:
The following example details the structure of the VBA Macro created by the simulation:
Sub UserRxnRates(ByRef Rate() As Double, ByVal Temp As Double,
ByVal Pres As Double, ByVal Rpm As Double, ByRef Conc() As Double,
ByRef KPar() As Single, ByVal ChemCADEntry As Object)
Rate(1) = RxnRate001(Temp, Pres, Rpm, Conc, KPar, ChemCADEntry)
Rate(2) = RxnRate002(Temp, Pres, Rpm, Conc, KPar, ChemCADEntry)
End Sub
The function array Rate returns the rates of the chemical reactions. Temp is the current temperature in
user units, Pres is current pressure in user units, Rpm is the propeller speed, Conc contains the array of
concentrations in user units, KPar carries the array of kinetic parameters, and ChemCADEntry is an
object handle used to access CHEMCAD. Ten kinetic parameters are currently assigned to each
reaction. The frequency factor and exponential term (including the activation energy and temperature)
are the first and second kinetic parameters respectively. The remaining kinetic parameters are reserved
at this time. The VBA code for the rate function of reaction no. 1 has the following form:
Function RxnRate001(ByVal Temp As Double, ByVal Pres As Double,
ByVal Rpm As Double, ByRef Conc() As Double, ByRef KPar() As Single,
ByVal ChemCADEntry As Object) As Double
RxnRate001 = …
End Function
The user can modify these macros using Excel’s VBA Editor. Additional information regarding the solid,
liquid, or vapor phases can be accessed through the ChemCADEntry object handle.
Modeling Biological Reactions:
Biological reactions can be modeled using the Kinetic Reactor (KREA) and Batch Reactor (CC-ReACS)
UnitOps in CHEMCAD.
Biological reactions are typically mass based. Therefore, the concentrations are given in terms of
mass/volume and the reaction rate equations are based upon the mass of substrate, biomass, and
products.
246
CC-DYNAMICS Version 5.5 User’s Guide
The Kinetic and Batch Reactor models both have a concentration option of mass/volume. This setting
also changes the reaction stoichiometry to units of mass. The rate expression A + 2B!"3 C is read as
“1 kg A +2kg B goes to 3kg C”.
Concentration Flag:
The Concentration Flag option is found on the second tab of the Kinetic Reactor Dialog Box. The
available settings are:
0 mole/volume Default mode
1 partial pressure
2 mass/volume Used for Biological Reactions (Stoichiometry becomes mass based)
Mode 2 is useful for biological reactions, which are often mass based. It is important to note that with
mode 2, stoichiometry becomes mass based!
The flow and volume units (option 0) are selected using parameters 21 and 23 respectively.
The pressure units (option 1) are the same as the global pressure units.
Stoichiometry screens:
If the exponential factor for a reactant is not specified, the stoichiometric coefficient will be used as the
default value.
2
Example: for A + 2B ↔ C, the rate will be r=FF * CA* CB
This does not apply to the User Added Kinetic Rate Expression.
A separate tab will appear for each reaction. The tab sequence corresponds to the order in which the
stoichiometric parameters were entered in the Kinetic Data dialog boxes.
247
User’s Guide CC-DYNAMICS Version 5.5
OVERVIEW
The dynamic vessel DVSL allows the user to include the static head pressure into piping network
calculations. This feature is handy when more realistic transient simulations are wished.
Since the liquid level in the vessel can vary during a process, the liquid static head variation might be
relevant to the pressure/flow calculations for both upstream and downstream UnitOps.
If there is an inlet liquid stream the liquid level in the vessel might rise and therefore the static head will be
higher for the next time step.
If there is an outlet liquid stream the liquid level in the vessel might drop and therefore the static head will
be lower for the next time step.
BASIC USE
If the static head is to be considered, the dynamic vessel will probably belong to a dynamic piping network
flowsheet such as the shown below:
In this example water is being pumped from an infinite source at a constant pressure.
The DVSL UnitOp will represent a pressure node in a piping network. Since the DVSL will be an external
piping node, at least one specification must be made. A piping node can usually accept two kinds of
specifications:
1. Fix the pressure
2. Fix the flow
This flowsheet was built to determine how long it would take to fill this tank. Since the flow is an unknown
variable for this dynamic calculation, the pressure must be fixed (to perform the network calculations).
Tip: In case you wanted to prevent DVSL from backward flow of inlet streams, you can
use CVAL and check its Forward flow only option. This will avoid false inlet flows.
248
CC-DYNAMICS Version 5.5 User’s Guide
For this example, after inputting the geometry of the vessel, the user should check the Include liquid static
head option. This will ensure that the static head is included into the pressure/flow calculations for the
inlet and outlet liquid streams. However, the position of the inlet nozzle will be important for DVSL to
estimate the column of liquid.
The actual static head relevant to the inlet liquid stream it that of the current liquid level above the nozzle.
DVSL lets the use specify the position of the nozzle from the top of the vessel. This means that if the inlet
nozzle is located at the very bottom of the vessel the inlet nozzle position to be input is the same as the
height of the vessel. Conversely, if the inlet nozzle is located at the very top of the vessel the inlet nozzle
position to be input is zero.
For outlet liquid nozzles the default position is at the bottom of the vessel. The picture below may help
the user understand this specification.
After inputting the vessel geometry and other simulations parameters the general dynamic vessel dialog
should look like the picture below. Please notice that for this example the inlet nozzle is located at the
very bottom of the vessel (the vessel height and the inlet nozzle position are the same).
249
User’s Guide CC-DYNAMICS Version 5.5
Results
In this example you can notice how the variation of the static head can affect process variables such as
the inlet flow, the outlet liquid pressure.
Liquid Level
Please look at the results of the liquid level. The plot does not really show that the variable static
head affects the behavior of the liquid level. However, this effect can be noticed in the following
plots.
250
CC-DYNAMICS Version 5.5 User’s Guide
Outlet pressure
This plot show how the outlet pressure decreases as the process goes on. Please notice that
the pressure in the vessel is 14.7 psia. The plot shows the sum of the vessel pressure plus the
static head.
251
User’s Guide CC-DYNAMICS Version 5.5
252
CC-DYNAMICS Version 5.5 User’s Guide
253
User’s Guide CC-DYNAMICS Version 5.5
Jacket Reactor Jacket Dished End Dished End Jacket Minimum Minimum
Flow Rate Weight Capacity Volume Inner Height Stir Volume Stir
Surface Impeller Volume
Area
m3/hr kg litres litres m2 mm litres Litres
44 18000 3405 6055.9 14.0 3369 10100 NA
44 14500 2965 4253.3 11.1 3445 8270 NA
30 11000 1605 3504.6 9.7 3191 6220 NA
30 9000 1410 2849.4 8.5 2925 3440 NA
30 7500 1260 2281.4 7.3 2717 3080 NA
23 6000 1100 1794.4 6.2 2517 2810 NA
23 5000 810 1794.4 6.2 1920 2160 NA
23 4300 725 1382.1 5.2 1848 1940 NA
23 3400 676 800.0 4.0 2234 1420 NA
23 2500 524 583.2 3.2 1767 1110 NA
15 1800 378 409.6 2.5 1147 870 NA
15 1400 294 274.4 1.9 991 610 NA
15 1000 214 172.8 1.4 842 210 292
15 700 151 100.0 1.0 703 125 181.5
10 500 120 51.2 0.6 743 62 103
10 400 93 34.3 0.5 552 46 74
5 300 70 21.6 0.4 501 33 47
5 250 46 13.3 0.3 401 21 32.8
5 220 32 13.3 0.3 214 21 33.5
254
CHEMCAD ™
The crucial point to effective project work, or to smooth plant operation is maintaining
consistent documentation for all disciplines. Here is our Multi-Discipline Concept:
Now, imagine you have drawn pipelines, equipment, and instrument tag numbers by a
P&ID package, and stored process data calculated with a simulator to the drawings'
database. Instrumentation engineers require all these data. What happens when they
change any tag number or process data? Traditionally, the documentation would become
inconsistent easily. With Multi-Discipline solution the data can be updated both ways.
The user can build the system from blocks and expand it as the needs grow.
2
Features of Multi-Discipline solution
• All programs work on networks, so engineers of different disciplines can
collaborate.
3
Here are some answers we have got from process
personnel of many producing plants:
5
Databoxes and graphics can be placed directly on flowsheet, forming together Main Process Flow
Diagram. Individual Process Flow Diagrams can be also created and edited.
1
Oil Refining and Petrochemicals
5 7
2
4
6 8
9
3
1
2 4
1
Steam Steam
3 10
DESCRIPTION:
Crude oil is heated in process furnace to 400 F. Then, it enters the tower T-1001 near to the tower bottom. The
tower is equipped with 12 stages, a condenser, one side stripper for naphtha, one side heat exchanger, and one
pumparound. The bottoms of the tower are heated to 600 F in the second furnace, and sent to the tower T-1002.
The latter is equipped with 15 stages, a condenser, two side strippers (for kerosene and diesel oil), one side heat
exchanger, and one pumparound.
The bottoms of both towers as well as all strippers are fed with live steam.
This example explains usage of the Tower Plus distillation model and the way of performing crude oil
characterization.
2
3
Dynamics: Properties of Continuous Distillation Column
DESCRIPTION:
4
5
Dynamics: Full Control Model
of Continuous Distillation Column
DESCRIPTION:
6
7
Blending of Crude Oil
DESCRIPTION:
CHEMCAD 5 has the ability to generate crude oil pseudo-components according to user provided
distillation curves. CHEMCAD 5 supports the following blending options:
The "Blend" option can generate pseudo-components by averaging distillation curves of all streams
under characterization.
The "No Blend" option allows characterizing crude oil streams individually, so pseudo-components
generated from different streams can be distinguished in the product streams. This makes evaluation of
distribution of various crude oils in the flowsheet easy.
CHEMCAD 5 does all reporting to user-selected editors or word processors, such as Microsoft Word,
and graphics can be copied directly to the Windows Clipboard. This way, you can freely compose your
reports using your favorite office software.
CHEMCAD has now Crude Oil Database as well. This contains properties of around 250 crude oils
including the properties of all oil fractions:
8
Dynamics: Liquefied Ethylene Storage Simulation
9
Cat-Cracker Gas Separation
DESCRIPTION:
This is a simulation of an existing process. Cracker gas is being mixed with recycled gas stream,
flashed, compressed to 12 kG/cm2 G, cooled by air cooler and an aftercooler, and flashed again. Net
gas and liquid from the compression stage are fed to a collector, which is a central point of the
operation from the balance point. Off-gas of this collector is sent to the absorber, which is also fed with
both stabilized (lean) and unstabilized naphtha. The top product of the absorber is hydrogen-enriched
gas.
The bottoms are transferred to the central collector. The liquid product of the collector goes to the
reboiled stripper (desorber), where the bottoms leave system as rich naphtha, and the top product
returns to the collector. This flowsheet illustrates CHEMCAD's usefulness in modeling multi-recycled
processes, applications of the Tower model for absorption, and desorption, as well as usage of special
thermodynamic coefficients for ethylene-propylene systems.
10
De-Isobutanizer Sample
DESCRIPTION:
11
Hydrotreater Unit Simulation
DESCRIPTION:
The example shows how to model refining technologies of undefined chemistry. The process is to
remove sulfur and nitrogen impurities from C6+ petro cut by hydrogenation.
The feedstock is pumped from tankage and mixed with recycle hydrogen gas. Then it is preheated with
hot reactor product gas in the CFEX heat exchanger. The reactor feed is then heated near to the
reaction temperature in a process furnace, and introduced to the adiabatic hydrogenation reactor.
In the reactor, sulfur and nitrogen impurities are converted into hydrogen sulfide and ammonia
respectively, and alkene bounds are being saturated. The heat of hot reaction gases is recovered in the
CFEX exchanger.
Heat is further recovered in the H2EX heat exchanger, where the recycled hydrogen is preheated. The
cooled mixture is sent to a drum separator, where gases are flashed off from the heavy liquid product.
The gases are washed with process water, cooled, and sent to a flash drum, where light hydrocarbon
product and wastewater are separated from the recycle gas. The recycle gas is purged to remove
excess H2S and NH3 produced in the process, the gas is re-compressed and mixed with fresh H2 make-
up stream, and the recycle returns to the process.
12
LLE Desulfurization of Liquefied Petroleum Gas
DESCRIPTION:
Traditional way of gas desulfurization involved absorption process, where H2S was being removed with
aqueous solution of mono- or diethanolamine. The new technology, becoming popular, is liquid-liquid
extraction of liquefied petroleum gas (LPG).
CHEMCAD includes modified both AMINe thermodynamic model of CHEMCAD as well as the modified
EXTRactor model able to simulate the new process possible.
CHEMCAD is a technology- and market-driven product, so market demands of common interest are
implemented in the program. This example shows how to set up the flowsheet to make use of the
special methods.
13
14
Propane-Propylene Splitter
DESCRIPTION:
Propane and propylene are very difficult to separate one from another, as they are close-boiling
components. Nonetheless, distillation at elevated pressure is a common technology, provided sufficient
number of trays exists in the distillation column.
Calculations of a 148 actual-tray tower are presented in this example. The SCDS distillation model was
used to accommodate big number of trays, and to account for actual trays.
Propane/propylene and ethane/ethylene vapor-liquid equilibria are affected by interactions between the
components. Special Binary Interaction Parameters for the Peng-Robinson Equation-Of-State were
used to reflect these non-idealities.
15
16
Sour Water Stripper
DESCRIPTION:
In this example, the Tower Plus (TPLS) model has been used to simulate stripping wastewater from
Hydrogen Sulfide and Ammonia down to the level of 5 ppm. This is another application of the TPLS
model, which is normally used to simulate atmospheric and vacuum distillation of crude oil.
The tower is equipped with a reboiler, and a pumparound is used to generate internal reflux.
A special thermodynamic model, SOUR, has been used to calculate equilibria in the system.
The picture below is the Process Flow Diagram including a Stream Databoxes. CHEMCAD 5 allows
placing Stream and Equipment Databoxes on a PFD, and you are free to select properties and the units
of measure that would appear there.
17
18
Vacuum Tower with TBP Assay
DESCRIPTION:
Atmospheric residue is distilled under vacuum into fuel oil, two grades of vacuum gas oil, and vacuum
residue. The preheated feed stream enters the bottom part of the tower, which is additionally heated.
Two pumparounds provide internal reflux.
The process has been modeled with a Tower Plus (TPLS) distillation module.
The example shows how flexible as to specifications the TPLS module is. (For instance, you may
replace a condenser with a pumparound, or the reboiler with side heat exchanger, if you need it.) It also
demonstrates characterization of the oil feed by TBP assay. (The figure below shows feed and product
characterization curves after automatic TBP-D1160 inter-conversion). A thermodynamic K-Value model
most suitable for vacuum distillation of heavy material was selected.
19
20
MTBE Process with H2SO4 Catalyst
DESCRIPTION:
MTBE is made commercially by catalytic reaction between methanol and i-butylene. A widely used
catalyst is an acidic ion exchange resin. This flowsheet shows the alternate route, where sulfuric acid is
used as catalyst. The flowsheet was made according to published data. (Al-Jarallah, A.M., and Lee,
A.K.K., "Economics of new MTBE design", Hydrocarbon Processing July 1988.)
The process is to make approximately 100,000 metric tons per year of the MTBE product.
A mixture of fresh and recycled methanol is mixed with a C4 stream and a mixture of fresh and recycled
sulfuric acid, and reacted at elevated temperature and pressure in two sets of multistage, intercooled
reactors in liquid phase. Most of H2SO4 is then separated in the settler and recycled to reaction. Sour
organic phase is then neutralized with alkali and washed with water. Methanol is recovered from the
aqueous phase by stripping with live steam and recycled to the process. The wash water recycle is
purged to avoid Na2SO4 build-up. Washed organic phase is distilled to separate the MTBE product from
spent butanes.
The Training Book explains the importance of Convergence Parameters in converging big, multi-
recycled flowsheets. Calculations of WAR Environmental Report have been demonstrated. This feature
allows the user to assess the environmental impact of waste streams.
21
CS2 Removal from Carbochemical BTX
Sensitivity Study, Optimization
DESCRIPTION:
Raw mixture of benzene, toluene and xylene derived from coal coking contains toxic and explosive
carbon disulfide, which is removed in dual-column distillation system.
First column actually removes CS2 from BTX, and the second one serves as the regenerator, in
attempt to minimize the losses of aromatics from the system.
Numerous process parameters influence CS2 recovery as well as the aromatics' losses, specifically the
loss of benzene.
Sensitivity Study tool allows the user to vary up to 2 any process parameters during the flowsheet
calculations, as well as recording up to 12 other parameters. The result of the analysis is the chart
showing the influence of the varied parameters on the process performance.
In this specific case, we have studied influence of the Column 1 condenser specifications on the CS2
recovery, benzene losses, and necessary recycle flowrate.
Alternative tool available in CHEMCAD 5 is Optimization. You can define the Objective Function, up to
10 Independent Variables and apply Constraints. Optimization usually achieves the solution much
faster than the Sensitivity Study does. You can combine Optimization with Costing tool and the
Calculator to optimize Investment Cost and Total Manufacturing Cost.
22
Natural Gas Processing
DESCRIPTION:
Currently, CHEMCAD includes 34 thermodynamic methods to determine phase equilibria, as well as
electrolyte package and solids as built-in features. K-Value methods vary from very universal to
specialized ones. Process natural gas dehydration with triethylglycol (TEG) has its own K-Value method
in CHEMCAD 5.
The flowsheet describes a typical dehydration unit. Gas enters the unit at 85 deg F, saturated with
water. It is dried in the dehydrator column at 500 psia by contact with lean TEG. The rich TEG is then
flashed, heated and regenerated with a combination of indirect heat and a slipstream of the dried gas.
The regeneration column has a reboiler, condenser and packed section below the reboiler. With this
flowsheet, the water removal from a process or natural gas stream as a function of operating variables
is calculated. The user may define circulating TEG flow, column pressures, flash pressure, stripping
gas flow and heat exchanger performance.
23
24
Dynamics: Natural Gas Transfer Station
DESCRIPTION:
This is a simulation of an existing technology. Natural gas at high pressure is reduced and distributed to
a local community. As gas temperature decreases during the expansion, gas is heated up by circulating
warm water, which in turn is heated up in a boiler. The boiler uses a part of gas as heating medium.
The demand for gas varies over time; therefore the process must be controlled.
The flowsheet was first solved in steady-state mode to determine initial state, then dynamics simulation
has been run. Ramp controller simulates varying demand for the gas. Two control loops exist in the
system: one to control water temperature after the boiler, and another to control gas supply to the
boiler’s burner.
25
Natural Gas Expansion with Temperature Control
DESCRIPTION:
The flowsheet has been based on actual plant data. Natural gas at 100+ bar G and 283 K is heated in the E-101
exchanger, and then itself heats the product gas in exchanger E-102 to satisfy market requirements. The wet gas
is then expanded with a valve, where the gas temperature decreases according to the Joule-Thompson effect.
Gasoline and water condensate is knocked out in a flash drum, and further it is decanted. Cool product gas is re-
heated in the E-102.
Temperature control is provided to prevent cooling the expanded gas below temperatures limited by material
specifications. As gas composition and pressure at the wellhead changes in time, the automated flowsheet like
this may serve for everyday field calculations and check-out. The behavior of the process can be also determined
via Sensitivity Analysis.
CHEMCAD 5 can also help the gas engineer in predicting hydrate formation. Given stream composition,
temperature and pressure, CHEMCAD 5 can tell whether a hydrate would form or not. It is possible to study the
influence of inhibitor (methanol, EG, DEG, or TEG) on hydrate formation. Using Dynamics (CC-ReACS or CC-
DCOLM module) you can study the behavior of the Control System when well capacity varies.
26
MEA Sour Gas Treatment Plant
DESCRIPTION:
A group of thermodynamic methods available in CHEMCAD 5 is intended for use with specific technical
applications. This is the case with Amine model, which is capable to predict equilibria for desulfurization
of gases with aqueous solutions of ethanolamines.
This flowsheet describes a typical monoethanolamine (MEA) sour gas treatment plant. Sour gas
containing approx. 0.5 mole % of H2S and 2 mole % of CO2 enters the absorber unit at 900 psig and
90 F. Acid gases are removed in the absorber column by contact with lean MEA (15 wt. % aqueous
solution). The rich MEA is then heated and regenerated in the stripper column at 26.2 psia. The
regeneration column has a reboiler and a partial condenser. Regenerated MEA passes through heat
exchanger to preheat the rich amine stream. It is then mixed with make-up MEA and water, boosted to
the absorption column's pressure, cooled, and directed onto the top of the absorber.
27
Organic Chemicals
DESCRIPTION:
This flowsheet proved that design specifications calculated with CHEMCAD 5 matched data of an
existing plant.
The feed to the process was saturated liquid containing 85 wt. % of isopropyl alcohol (IPA) and 15 wt.
% of water. IPA-water system forms azeotrope of about 88 wt. % IPA at 4 bar abs. Cyclohexane was
used as azeotrope-breaking component (the entrainer). The requirement was to produce 95 wt. % IPA,
virtually cyclohexane-free. For environmental and economy reasons, wastewater from the process had
to be cyclohexane-free, too.
IPA/water separation set- up were two distillation columns operating under different pressures. The
primary separation (IPA) was occurring in the first column. and the solvent was recovered in the second
one.
Specific problems related to this process: highly non-ideal system, distillation, recycles are easily
handled with built-in modern thermodynamic methods, flexible SCDS distillation/absorption /stripping
model, and automatic loop convergence tools.
28
Dynamics: Adsorption System Studies
29
30
MEK Process. Dehydrogenation of sec-Butanol
DESCRIPTION:
The flowsheet shows a technology to make 15,000 MTPY of methyl ethyl ketone (MEK) by sec-butanol
(SBA) dehydrogenation. It is a design study.
Fresh SBA is pumped onto the top of a scrubber (1), where residual MEK is removed from a byproduct
hydrogen stream. Then SBA is vaporized and superheated before it enters the reactor system (6),
where sec-butanol is dehydrogenated in a vapor phase reaction over a solid catalyst:
The reaction is highly endothermic and it is typically carried out in several reactors connected in parallel
or in series.
The reactor effluent is condensed, and hydrogen is flashed off. Crude MEK enters the distillation
column (7), where MEK-H2O azeotrope goes to the top. The product is dehydrated on a rock salt bed,
and the MEK-rich phase is condensed and recycled to the azeo column. Dried mixture of unconverted
SBA and MEK is then distilled into 99.5 wt. % MEK product and SBA, the latter being recycled to the
process feed stream.
Example in the Training Book explains handling multiple recycles, a reactor model, non-ideal VL
equilibria, controllers, and modeling special operations, like rocksalt bed unit.
31
32
Dynamics: Methanol Evaporator Model
DESCRIPTION:
Vessel temperature
33
34
The Phthalic Anhydride Process
DESCRIPTION:
One of the routes to make Phthalic Anhydride (PA) is to oxygenate o-Xylene with air in a catalytic
process.
Extensive laboratory/computational work has been carried out to develop actual kinetic model for the
reactor. Then the data were input to CHEMCAD's Kinetic Reactor model as the Extended Kinetic
Equation. Heat transfer was also included into the model.
As we were not permitted by the technology owner to publish data, the Training Book example involves
simpler model for a similar process.
Reactive absorption has been employed to model a scrubber converting anhydrides into respective
carboxylic acids.
35
36
Ethyl Acetate by Reactive Distillation
DESCRIPTION:
For reversible reactions, the equilibrium state can be shifted in desired direction by, i.a., adding one of
reactants in excess or removing products from the reaction mass. This principle is the background of
reactive distillation technique. Products are separated and removed from the distillation column due to
difference in their relative volatilities, and due to counter-current reactants' flow, reactants are in excess
to each other at several column stages.
This example shows how easily CHEMCAD 5 can cope with reactive distillation and extremely non-
ideal systems. Not only is a reversible reaction there; Acetic Acid, Ethanol, Water, and Ethyl Acetate
form a thermodynamically complex system with two-liquid phases and vapor phase association. For a
chemical engineer, though, the only task is to correctly select thermodynamic models, enter reaction(s)
equilibrium or kinetic coefficients, and specify the column as he would do with more 'typical' distillation;
CHEMCAD 5 will do the rest.
37
38
Ammonia Syngas Plant
DESCRIPTION:
Real life technology to make 3:1 H2/N2 syngas has been shown. It involves processes such as methane
conversion with steam and air, CO to CO2 conversion (the Shift reaction), and the methanation reaction. The
flowsheet includes multiple recycle loops.
CHEMCAD 5's Equilibrium Reactor and Gibbs Reactor models are perfectly fit to rigorously calculate reactions
involved in syngas manufacture. The Equilibrium Reactor has equilibrium constants for methanation/shift reaction
built-in, so it does not require any intervention from the user.
CHEMCAD 5 is very useful in everyday plant operation. Once the plant has been modeled with a flowsheet (even
a simplified one), it is very easy to find out the process bottlenecks, units with excessive utility consumption, etc.
Very often, it is enough to change some process parameters to save substantial money and to make better
product with existing equipment. Sometimes a small revamp would be adequate. When the story is the heat
exchanger, the additional module CC-Therm can help to rate existing exchanger, make modifications in the heat
exchanger, or design a new one. It has been proven that the savings achieved with CHEMCAD and CC-Therm
can exceed many times the initial license cost.
39
40
Acrylonitrile/Acetonitrile Extractive Distillation
with Sensitivity Study
DESCRIPTION:
This example presents a very difficult problem where the range of desired operation is extremely
narrow. A purge or pasteurization column is used to separate two very close boiling organics,
acetonitrile (ACN) from acrylonitrile (ACR). These cannot be separated by conventional distillation, so
large excess of water is added, causing a shift in relative volatilities, thus making the separation
feasible.
This is a typical example for extractive distillation.
The process is extremely difficult to calculate due to complex thermodynamics. The Sensitivity Study
option saves time needed by the engineer to find the carefully balanced process conditions.
41
Dynamics: Typical Batch Technology,
Reactor and Distillation
DESCRIPTION:
A typical study of a batch reaction system has been presented here. Acetic acid made to react
with butyl alcohol in a batch reactor. Water, the unwanted product of the reaction, is removed
from the system by azeotropic distillation.
In this case, the main interest is the chemical reaction. Rate regression facility has been
demonstrated. The control system can be added in the next phase, as other dynamic
examples presented in this book show.
42
Benzene Hydrogenation to Cyclohexane (32,000 MTPY)
DESCRIPTION:
This is a classic case study of conceptual process design. Given desired plant capacity, an overall
process layout is to be developed. In this sample, 32,000 metric tons per year of cyclohexane is to be
produced by hydrogenation of benzene. The reaction equilibria were taken from literature.
First step of the design involves solving the flowsheet 'forward', i.e., without any recycle loop. Once it is
done, and behavior of unit operations has been determined, the recycle loops would be closed, and
then the overall process balance found.
With the flowsheet ready, it is very easy to examine the influence of various process parameters on
equipment size or utility consumption. A Sensitivity Analysis option has been demonstrated as an
invaluable tool for this type of examination.
CHEMCAD 5 incorporates Costing option. The cost of typical equipment units can be calculated by
Chemical Engineering methodology at level of Preliminary Estimates. The source code has been
written as Calculator/Parser in simple CHEMCAD Inline-C language, and the calculational methods are
accessible for the users. The users can modify all costing procedures according to their local needs,
data, and they can even write completely new costing formulas. CHEMCAD, thus no need for
expensive compiler, instantly executes any change applied to the costing procedures.
43
Inorganics and Environmental Protection
DESCRIPTION:
44
CO2 Removal by the Benfield Process
DESCRIPTION:
What you can see in the picture above is the simulation of an existing plant to remove CO2 from a
process stream by absorption/regeneration with a hot potassium carbonate solution. CO2 is absorbed
by chemical reaction, and it is the type of calculations CHEMCAD 5 Electrolyte Package has been
made for.
This sort of simulation requires applying the True Species Approach, where regular components and
electrolyte species are treated equally.
CHEMCAD 5 has a database of ionic reactions built-in. Many industrially important systems have been
covered. In case some reaction data are missing, CHEMCAD 5 would try to calculate equilibrium
coefficients. Electrolyte Regression facility is also available.
45
Wet Desulfurization of Flue Gas
DESCRIPTION:
One of methods to clean up flue gas is the wet process. Aqueous lime suspension is introduced onto the top of a
spray tower, and flue gas counter-currently contacts liquid droplets. Sulfur dioxide is converted into sulfites, and
CO2 is released.
Enhanced electrolyte package being an integral portion of CHEMCAD 5 makes this sort of calculations feasible.
The unique True Species Approach treats electrolyte species as they were regular components, so the
calculation results reflect true distribution of material into molecules and ions. The Electrolyte Expert tool helps
setting up the electrolyte system very effectively; this action is almost transparent to the user.
Stream No. 1 2 3 4
Stream Name Lime + H2O Flue gas Clean Gas Sulfite
Temp C 20.0000* 40.0000* 15.2654 15.1076
Pres bar 1.1000* 1.1000* 1.0000 1.0000
Ph value 10.1498 0.0000 0.0000 6.2584
Ionic strength molal 0.0006 0.0000 0.0000 3.2546
Total kg/hr 55296.2303 1800000.0139 1819076.1812 36219.9106
Flowrates in kmol/hr
Sulfur Dioxide 0.0000 28.0965 0.0005 0.0000
Carbon Dioxide 0.0000 4089.9795 4114.8903 0.0824
CalciumCarbonate 52.9916 0.0000 0.0000 27.6882
Water 2774.9948 0.0000 1098.0072 1673.8902
Nitrogen 0.0000 57764.0000 57764.0000 0.0214
CO3-- 0.0033 0.0000 0.0000 0.0008
HCO3- 0.0051 0.0000 0.0000 0.3176
HSO3- 0.0000 0.0000 0.0000 5.8884
SO3-- 0.0000 0.0000 0.0000 22.2080
Ca++ 0.0084 0.0000 0.0000 25.3118
46
Selective H2S Removal with MDEA
DESCRIPTION:
This example is a selective H2S removal by using 50 weight % MDEA in a 10 tray absorber.
This problem was calculated by the Apparent Component electrolyte method, where 'visible'
components are separated from the ionic species.
The constants for the MDEA process have been taken from the CHEMCAD's ionic reaction library.
CHEMCAD 5 includes enhanced SCDS distillation/absorption model. It allows specifying stage
efficiencies for individual column trays, as well as stage efficiencies for individual components. In this
example, the CO2 absorption is controlled by mass transfer, so individual stage efficiencies for carbon
dioxide have been applied.
Ref: Jou, F. Y. F.D. Otto and A. E. Mather, "Solubility of Mixtures of H2S and CO2 in a
Methyldiethanolamine Solution". Paper #140b AIChE Annual Meeting, Miami Beach, FL (Nov 2-7,1986)
47
Ammonia Absorber, Carbamate System
DESCRIPTION:
Off-gas of the urea plant contains considerable amount of ammonia that must be recovered before the
offgas is disposed. The commercial product of the unit is concentrated aqueous ammonia solution. As
hydrogen is present in the system, nitrogen is introduced to dilute off-gas to concentrations below
explosion limits. Calculation of the process was never simple, because carbon dioxide, ammonia, and
water form carbamate in a reversible reaction, and the equilibria heavily depend on temperature,
pressure, and concentrations.
The calculated results have been positively compared to those measured at operating production unit.
The Electrolyte option was applied.
Interesting fact is that the CHEMCAD user can track the varying compositions of CO2, NH3, H2O, and
the carbamate throughout
the process. Both
Apparent Components
and True Species
methods can be used to
calculate ionic behavior of
the system.
It is important that once
the Electrolyte option has
been launched, the user
can concentrate on
solving the problem in the
usual way, and
CHEMCAD takes care of
handling the ionic system
in the background.
48
Dynamics: Cooling of a Batch Crystallizer
49
Power Generation
DESCRIPTION:
A typical gas turbine consists of an axial compressor, fuel combustion chamber and an
expander which drives the compressor and any external load or loads. For modeling purposes
only, the work to drive the compressor and external loads are considered separately. The
design or rating of a turbine system depends on how the controls are configured. CHEMCAD 5
can define the theoretical work requirements and fuel for a defined load or frame size.
This example defines the air and fuel requirements for a turbine, which drives an electrical
generator under combustion conditions, as defined by excess air requirement.
50
Power Plant Steam Balance
DESCRIPTION:
CHEMCAD 5 is an invaluable tool for balancing a power plant. In this example, general
balance of a three-stage turbine power plant block was calculated. This block was aimed at
electricity production. Special care was taken to balance the condensate tank. When water is
the only component in the system, using the "Ideal Vapor pressure" thermo model makes
CHEMCAD use digital steam tables, thus ensuring high accuracy of steam/water calculations.
51
52
Detailed Model of an Industrial Power Plant
DESCRIPTION:
CHEMCAD 5 can be used for optimizing operation of an existing plant. This flowsheet presents a single
block of a big industrial power plant, producing simultaneously electricity and HP, MP, and LP steam for
a chemical plant.
This block has seven turbine sections: six of non-condensing type and one of condensing operation.
Depending on current demand, the power plant manager can decide upon steam distribution in the
system. Specific streams can be shut (actually one of steam outlets has been deliberately closed.) This
flowsheet has been made non-optimal on purpose. A CHEMCAD user can play with controllers,
especially with those responsible for operation of re-heaters, to increase overall thermal efficiency of
the plant.
A very useful feature of CHEMCAD 5.1 is capability to write own programs and unit operations in Visual
Basic (in Excel or as Visual Basic Professional applications.
For the example under consideration, an unit operation to calculate current thermal efficiency of the
plant has been made in Excel. The calculated efficiency can be the input to CHEMCAD Optimization
tool.
53
Cosmetics, Food, Pharma, Pulp and Specialty Industries
DESCRIPTION:
The CC-Batch module is a package for rigorous calculations of batch distillation processes.
A new packed column, equivalent to 34 theoretical plates, was designed to separate Citronella oil into
citronellal and mixture of citronellol and geraniol. The process had to be carried out under vacuum of
order of 1 mmHg.
The properties of essential oil components have been calculated with prediction features of CHEMCAD.
54
Dynamics: Typical Batch Distillation System
55
Optimizing a Glycerol Evaporation Plant
DESCRIPTION:
56
Dynamics: Vessel, CV, and Controller Study
DESCRIPTION:
This is one of simple examples from the Training Book, helping the user learn the basics of dynamic
simulation in CHEMCAD (CC-ReACS and CC-DCOLM modules).
Input flowrate [kg/h] against time Liquid level [mm] in vessel against time
Outlet valve opening [%] against time Outlet flowrate [kg] against time
57
58
Absolute Ethanol Manufacture, Steady State Simulation
DESCRIPTION:
A typical steady state design or rating calculation for azeotropic distillation with entrainer.
In this specific job, ethanol/water subazeotropic mixture is being distilled with n-pentane as an
entrainer. It is easy to replace n-pentane with other medium, such as cyclohexane. In first column,
water and entrainer free ethanol is produced in the bottom of the column. Three component azeotrope
is sent to a condenser's decanter, where organic phase is sent back to the first column top, and water
rich phase goes to a regeneration column. The second column ensures splitting water from organic
substances, latter also being recycled back to the process. Minor losses of the entrainer are made up,
and a steady state controller maintains the overall mass balance.
• Sizes of both columns, including theoretical and actual number of separation stages: this
corresponds to calculated number of actual trays or height of packing (structured or random)
• Column hydraulics
• Heat duties of condensers and reboilers. You can design or rate these exchanger in detailed way
with CC-Therm module.
• Tower profiles: concentration, temperature, pressure, flowrate and fluid properties for each tray
• Temperatures, pressures, flowrates, concentrations and fluid properties for each stream in the
flowsheet
• You can run costing, sensitivity studies and optimization of the flowsheet.
Having CC-DCOLM dynamic module, you can turn the flowsheet into a dynamic one, calculate control
valves and controller settings, simulate startup and shutdown of the system, as operation of the
process unit in time with varying process parameters.
59
60
Dynamics: Batch Flowsheet Simulation
DESCRIPTION:
This is an example of batch flowsheet simulation. “Batch flowsheet” denotes a train of processes
operated batch-wise. Batch and continuous processes can be combined.
In the picture at the left-hand side, solid-liquid suspension undergoes batch vacuum filtration over 4
hours and 55 minutes. Remaining liquid is removed by centrifugation over 11 minutes, then the cake is
washed (the process not shown), and finally the solid is dried with nitrogen over 6 hours.
Vacuum filter capacity and required batch process time can be calculated
Centrifuge capacity and required batch process time can be calculated
Consumption of nitrogen for drying process can be calculated and the final quality of the solid
product is determined by kinetics of drying
Overall mass and heat balance can be determined
61
Mass of solvents bounded in solid against drying process time
62
Dynamics: Stripping Biogas Permeate.
Process Desing and Start-up Study
DESCRIPTION:
Permeate from biogas production, 18000 kg/h, containing 0.6 wt. % of ammonia, 0.3 wt. % of carbon
dioxide, and water is to be separated into 15 wt. % ammonia as byproduct. The wastewater must be
purified to 50 ppm of ammonia.
The design task is to find distillation column operating parameters and size. This is traditional design
according to steady state solution. Ultimate task is to simulate real system in dynamics to determine
whether assumed equipment parameters would allow startup and normal operation of the distillation
column.
The steady state design gave these results:
Continuing the steady state calculation in CHEMCAD, it would be possible to get concentration,
pressure and temperature profiles of the column, as well as tray or packing hydraulic calculations. With
CC-Therm module, heat exchangers for condenser and reboiler could be designed. Size of vessels
could be determined. CHEMCAD can do all calculations and produce all documentation required
for traditional steady state process design.
It is more interesting, however, to design and simulate a real system to avoid future operation
problems. Steady state calculations have been performed at preparatory stage, to determine required
equipment sizes and initial state of the dynamic simulation. For instance, it is necessary to know heat
transfer area of heat exchangers and heat transfer coefficient. Sizes of reboiler and overhead tank, as
well as initial loads must be determined.
63
64
The picture below shows handy calculation to determine condenser system parameters.
After the preparatory phase, it was possible to set up dynamic flowsheet (see picture at previous page)
that simulates start-up of the distillation column (total startup time is 35 minutes). For simplicity, built-in
controllers have been used.
Vapor distillate compositions over time. The system can reach constant desired ammonia
concentration after 50 minutes
65
Vapor distillate mass flow rate over time
Composition of bottoms. Bottoms can reach desired purity after 52 minutes from the start of the
process
66
Reflux rate over time
67
Composition at the top of the column (liquid phase) over time
The presented model can be easily expanded into full system including heat exchangers, control
valves, PID controllers, etc.
68
Dynamics: Fermentation kinetics
DESCRIPTION:
CHEMCAD’s reaction module, CC-ReACS can be used to simulate fermentation tanks. The Batch
Reactor model allows simulation including heating, cooling, and agitation, Batch, semi-batch and
continuous fermentation can be calculated. Real equipment. control valves, and PID controllers can be
used. Batch scheduling is possible.
When simulating biotechnology processes, the key point is to apply appropriate bioreaction chemistry.
CHEMCAD gives now the user a chance of entering own kinetic equations of any form, and store the
equations in Excel.
This way, entering the Michaelis-Menten kinetic equation for fermentation is not a problem anymore.
69
The picture above shows concentrations of enzyme and enzyme-substrate complex as function of time
in one of test runs.
70
CHEMCAD
USER’S GUIDE
CC-STEADY STATE
And
CC-BATCH
Tutorial
LICENSE AGREEMENT
i
LIMITED WARRANTY
The Licensed Program(s), i.e. the tangible proprietary software, is provided "AS IS" WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, AND EXPLICITLY EXCLUDING ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The
entire risk as to the quality and performance of the Licensed Program(s) is with you.
Some jurisdictions do not allow the exclusion of limited warranties, and, in those jurisdictions the above
exclusions may not apply. This Limited Warranty gives you specific legal rights, and you may also have
other rights which vary from one jurisdiction to another.
Chemstations Inc. does not warrant that the functions contained in the Licensed Program(s) will meet your
requirements or that the operation of the program will be uninterrupted or error free.
Chemstations Inc. does warrant, however, that the diskette(s), i.e. the tangible physical medium on which
the Licensed Program(s) is furnished, to be free from defects in materials and workmanship under normal
use for a period of ninety (90) days from the date of delivery to you as evidenced by a copy of your receipt.
Chemstations Inc. warrants that any program errors will be fixed by Chemstations Inc., at Chemstations'
expense, as soon as possible after the problem is reported and verified. However, only those customers
current on their update/maintenance contracts are eligible to receive the corrected version of the program.
ENTIRE AGREEMENT
This written Agreement constitutes the entire agreement between the parties concerning the Licensed
Program(s). No agent, distributor, salesman or other person acting or representing themselves to act on
behalf of Chemstations Inc. has the authority to modify or supplement the limited warranty contained
herein, nor any of the other specific provisions of this Agreement, and no such modifications or
supplements shall be effective unless agreed to in writing by an officer of Chemstations Inc. having
authority to act on behalf of Chemstations Inc. in this regard.
LIMITATIONS OF REMEDIES
Chemstations' entire liability and your exclusive remedy shall be:
a) The replacement of any diskette not meeting Chemstations' "Limited Warranty" as
defined herein and which is returned to Chemstations Inc. or an authorized
Chemstations dealer with copy of your receipt, or
b) If Chemstations Inc. or the dealer is unable to deliver a replacement diskette which is
free of defects in materials or workmanship, you may terminate this License Agreement
by returning the Licensed Program(s) and associated documentation and you will be
refunded all monies paid to Chemstations Inc. to acquire the Licensed Program(s).
IN NO EVENT WILL CHEMSTATIONS INC. BE LIABLE TO YOU FOR ANY DAMAGES, INCLUDING ANY
LOST PROFITS, LOST SAVINGS, AND OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OR INABILITY TO USE THE LICENSED PROGRAM(S) EVEN IF
CHEMSTATIONS INC. OR AN AUTHORIZED CHEMSTATIONS DEALER HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM BY ANY OTHER PARTY.
SOME JURISDICTIONS DO NOT PERMIT LIMITATION OR EXCLUSION OF LIABILITY FOR
INCIDENTAL AND CONSEQUENTIAL DAMAGES SO THAT THE ABOVE LIMITATION AND EXCLUSION
MAY NOT APPLY IN THOSE JURISDICTIONS.
ii
GENERAL
The initial license fee includes one (1) year of support, maintenance, and enhancements to the program.
After the first one (1) year term, such updates and support are optional at the then current update fee.
Questions concerning this License Agreement and all notices required herein shall be made by contacting
Chemstations Inc. in writing at Chemstations Inc., 2901 Wilcrest, Suite 305, Houston, Texas, 77042, by
telephone, 713-978-7700, or by Fax, 713-978-7727.
DISCLAIMER: CC-STEADY STATE, CC-BATCH, CC-DYNAMICS, CC-THERM, CC-FLASH,
CC-SAFETY NET, CC-LANPS
Copyright(c) Chemstations Inc., 2004, all rights reserved.
This proprietary software is the property of Chemstations, Inc. and is provided to the user pursuant to a
Chemstations Inc. program license agreement containing restrictions on its use. It may not be copied or
distributed in any form or medium, disclosed to third parties, or used in any manner except as expressly
permitted by the Chemstations Inc. program license agreement.
THIS SOFTWARE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED. NEITHER CHEMSTATIONS INC. NOR ITS AUTHORIZED REPRESENTATIVES SHALL HAVE
ANY LIABILITY TO THE USER IN EXCESS OF THE TOTAL AMOUNT PAID TO CHEMSTATIONS INC.
UNDER THE CHEMSTATIONS INC. PROGRAM LICENSE AGREEMENT FOR THIS SOFTWARE. IN NO
EVENT WILL CHEMSTATIONS INC. BE LIABLE TO THE USER FOR ANY LOST PROFITS OR OTHER
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF USE OR INABILITY TO USE THE
SOFTWARE EVEN IF CHEMSTATIONS INC. HAS BEEN ADVISED AS TO THE POSSIBILITY OF SUCH
DAMAGES. IT IS THE USERS RESPONSIBILITY TO VERIFY THE RESULTS OF THE PROGRAM.
iii
iv
CC-STEADY STATE VERSION 5.4
TABLE OF CONTENTS
i
To Find a Topic in Help .............................................................................................................. 25
To Copy Information from a Help Topic ..................................................................................... 26
To Print a Help Topic ................................................................................................................. 26
To View a List of Topics You’ve Seen........................................................................................ 27
To Search for Words or Phrases................................................................................................27
To Customize the Search for Words or Phrases ........................................................................ 27
ii
Getting Started .......................................................................................................................71
Starting A New Job – The Simulate Flowsheet Window ...........................................................................73
Selecting Engineering Units......................................................................................................................75
Drawing the Flowsheet .......................................................................................................................76
Putting Streams on the Flowsheet ............................................................................................................80
Selecting Components .......................................................................................................................82
Selecting Thermodynamic Options ...........................................................................................................85
Defining the Feed Streams .......................................................................................................................87
Inputting Equipment Parameters ..............................................................................................................87
Pot Charge Definition .................................................................................................................87
Batch Column Specifications......................................................................................................87
Operation Parameters Specification...........................................................................................87
Set Screen Information Specifications........................................................................................87
Copy Operation Step Specifications...........................................................................................88
Specifying the Pot Charge Composition and Condition ............................................................................88
Specifying the Column Configuration........................................................................................................90
Defining the Operating Steps....................................................................................................................91
Operating Step 1 .......................................................................................................................91
Operating Step 2 .......................................................................................................................95
Operating Step 3 .......................................................................................................................96
Operating Step 4 .......................................................................................................................98
Operating Step 5 .......................................................................................................................98
Runtime Information ...................................................................................................................99
Running the Simulation .....................................................................................................................100
Reviewing the Results Interactively ........................................................................................................102
Plotting the Results .....................................................................................................................102
Reviewing Batch Results .....................................................................................................................105
Generating a Full Report .....................................................................................................................105
Summary .....................................................................................................................106
iii
Details .................................................................................................................... 116
How to Select Flowsheet Engineering Units........................................................................................... 117
Resetting Current Units to a Predefined Profile........................................................................ 118
Edit Current Engineering Units Profile...................................................................................... 119
Create a Default Engineering Units Profile............................................................................... 119
Create a User Engineering Units Profile .................................................................................. 120
Graphics Commands – An Overview ..................................................................................................... 120
Drawing Flowsheets in the Edit Flowsheet Mode..................................................................... 120
Graphics Features of the Plot Window..................................................................................... 121
Using the PFD Window ............................................................................................................ 121
The Edit Flowsheet Mode .................................................................................................................... 122
The Main Palette .................................................................................................................... 122
Sub-Palettes .................................................................................................................... 124
The Size and Shape of the Palette........................................................................................... 125
Hiding and Calling the Palette.................................................................................................. 125
Moving the Palettes.................................................................................................................. 126
Drawing With the Palette .................................................................................................................... 126
Drawing Lines .................................................................................................................... 126
Drawing Rectangles ................................................................................................................. 126
Drawing Ellipses .................................................................................................................... 127
Drawing Polylines .................................................................................................................... 127
Drawing Polygons .................................................................................................................... 127
Text .................................................................................................................... 128
How to Put Text on a Drawing................................................................................................................ 128
The Format Command .................................................................................................................... 128
Bring to Front .................................................................................................................... 129
Send to Back .................................................................................................................... 129
Fill Pattern .................................................................................................................... 130
Pen Style ....................................................................................................................130
Arrowheads .................................................................................................................... 130
Color .................................................................................................................... 130
Font .................................................................................................................... 131
Align .................................................................................................................... 131
Import Bitmap .................................................................................................................... 131
How to Rotate an Object Using the Palette ............................................................................................ 132
How to Move, Modify, Delete, or Flip Objects......................................................................................... 132
Moving a Single Object ............................................................................................................ 132
Moving Multiple Objects ........................................................................................................... 132
Panning the Flowsheet............................................................................................................. 133
Resizing ....................................................................................................................133
Deleting ....................................................................................................................133
Flipping an Object’s Y-Axis ...................................................................................................... 133
How to Copy to the Clipboard................................................................................................................. 133
Using the Metafile .................................................................................................................... 133
Using the Copy Command ....................................................................................................... 134
How to Generate a DXF File .................................................................................................................. 134
iv
How to Draw a Flowsheet .....................................................................................................................134
Step 1: Enter the Edit Flowsheet Mode ....................................................................................134
Step 2: Place Unitops on the Flowsheet...................................................................................136
Step 3: Connecting Unitops with Streams ................................................................................137
Step 4: Modifying and Adding to the Flowsheet .......................................................................138
How to Add Unitops to the Flowsheet.....................................................................................................138
Briefly .....................................................................................................................139
Details .....................................................................................................................139
Drawing Streams .....................................................................................................................140
Drawing Simple Streams (One or Less Direction Change).......................................................141
Drawing Complex Streams (Multiple Direction Changes).........................................................141
How to Select Components for the Component List ...............................................................................141
Calling the Component List Dialog Box ..................................................................................................142
Using the Component List Dialog Box ....................................................................................................142
Briefly .....................................................................................................................143
Details .....................................................................................................................143
How to Select K-Value Options ..............................................................................................................144
Briefly .....................................................................................................................145
Details .....................................................................................................................145
How to Select Enthalpy Options .............................................................................................................146
Briefly .....................................................................................................................146
Details .....................................................................................................................147
How to Define the Feed Streams............................................................................................................148
Briefly .....................................................................................................................148
Details .....................................................................................................................149
How to Specify Unit Operations ..............................................................................................................152
Calling a Unitop Dialog Box......................................................................................................152
Rules for Completing the Unitop Dialog Boxes.........................................................................152
Degrees of Freedom and Unitop Dialog Boxes ........................................................................152
How to Run Simulations in CHEMCAD Suite .........................................................................................153
Running Steady State Simulations ...........................................................................................153
How to Review Stream Compositions.....................................................................................................155
Selecting Streams ....................................................................................................................155
How to Set Flow Units for Results and Reports ......................................................................................156
How to View Stream Properties Using the Results Command ...............................................................157
Using the Properties Option Dialog Box ...................................................................................157
How to Plot .....................................................................................................................157
Plot Menu Options....................................................................................................................158
How to Create Reports .....................................................................................................................176
Calculate and Give Results ......................................................................................................177
Report Formats .....................................................................................................................177
Select Streams .....................................................................................................................178
Select Stream Properties..........................................................................................................180
Stream Flowrate/Composition ..................................................................................................181
Distillation Summaries ..............................................................................................................181
Heating Curves .....................................................................................................................182
v
Batch/Dynamic Results ............................................................................................................ 182
Miscellaneous .................................................................................................................... 183
End Report .................................................................................................................... 183
How to Create PFD’s .................................................................................................................... 184
Creating the Main PFD............................................................................................................. 184
Creating Secondary PFD’s....................................................................................................... 185
Opening and Editing Secondary PFD’s.................................................................................... 185
Adding a Stream Databox to the PFD .................................................................................................... 186
Step 1: Select the Streams to be Included in the Databox ....................................................... 187
Step 2: Complete the PFD Properties Options Dialog Box ...................................................... 187
Step 3: Complete the Databox Settings Dialog Box................................................................. 189
Step 4: Move and Stretch the Databox .................................................................................... 189
Adding a Unitop Databox to a PFD ........................................................................................................ 189
Step 1: Select the Unitops for Databox Generation.................................................................. 190
Step 2: Complete the Databox Settings Dialog Box................................................................. 190
Step 3: Move and Stretch the Databox .................................................................................... 190
Adding a TP Box to a PFD .................................................................................................................... 191
Select the Options to be Displayed .......................................................................................... 192
Select Streams from Flowsheet ............................................................................................... 193
Move the TP Boxes as Desired................................................................................................ 193
Running a Dynamics Simulation............................................................................................................. 193
The Steps for Setting Up a Dynamic Flowsheet....................................................................... 193
Starting a New Job................................................................................................................... 194
Selecting Engineering Units ..................................................................................................... 194
Draw the Flowsheet ................................................................................................................. 194
Make Sure the Dynamics Mode is Turned On ......................................................................... 195
Select Components.................................................................................................................. 196
Select Thermodynamic Options ............................................................................................... 196
Specify Feed Streams and Stream Initial Conditions ............................................................... 196
Specifying UnitOps................................................................................................................... 196
Specifying Runtimes, Time Steps, and/or Stop Criteria ........................................................... 196
Running the Dynamic Simulation ............................................................................................. 197
Re-Running and Extending the Run......................................................................................... 200
How to Run a Sensitivity Analysis .......................................................................................................... 201
Completing the Independent Variable Dialog Box.................................................................... 203
Completing the Dependent Variable Dialog Box ...................................................................... 204
Using Optimization in CHEMCAD .......................................................................................................... 204
How to Build User Added Symbols and Icons ........................................................................................ 209
Symbol Builder Palette .................................................................................................................... 210
Procedure for Building and Saving Unitop Icons .................................................................................... 211
User Added Palette Names .................................................................................................................... 213
vi
CC-STEADY STATE VERSION 5.4
TABLE OF CONTENTS
i
To Find a Topic in Help .............................................................................................................. 25
To Copy Information from a Help Topic ..................................................................................... 26
To Print a Help Topic ................................................................................................................. 26
To View a List of Topics You’ve Seen........................................................................................ 27
To Search for Words or Phrases................................................................................................27
To Customize the Search for Words or Phrases ........................................................................ 27
ii
Getting Started .......................................................................................................................71
Starting A New Job – The Simulate Flowsheet Window ...........................................................................73
Selecting Engineering Units......................................................................................................................75
Drawing the Flowsheet .......................................................................................................................76
Putting Streams on the Flowsheet ............................................................................................................80
Selecting Components .......................................................................................................................82
Selecting Thermodynamic Options ...........................................................................................................85
Defining the Feed Streams .......................................................................................................................87
Inputting Equipment Parameters ..............................................................................................................87
Pot Charge Definition .................................................................................................................87
Batch Column Specifications......................................................................................................87
Operation Parameters Specification...........................................................................................87
Set Screen Information Specifications........................................................................................87
Copy Operation Step Specifications...........................................................................................88
Specifying the Pot Charge Composition and Condition ............................................................................88
Specifying the Column Configuration........................................................................................................90
Defining the Operating Steps....................................................................................................................91
Operating Step 1 .......................................................................................................................91
Operating Step 2 .......................................................................................................................95
Operating Step 3 .......................................................................................................................96
Operating Step 4 .......................................................................................................................98
Operating Step 5 .......................................................................................................................98
Runtime Information ...................................................................................................................99
Running the Simulation .....................................................................................................................100
Reviewing the Results Interactively ........................................................................................................102
Plotting the Results .....................................................................................................................102
Reviewing Batch Results .....................................................................................................................105
Generating a Full Report .....................................................................................................................105
Summary .....................................................................................................................106
iii
Details .................................................................................................................... 116
How to Select Flowsheet Engineering Units........................................................................................... 117
Resetting Current Units to a Predefined Profile........................................................................ 118
Edit Current Engineering Units Profile...................................................................................... 119
Create a Default Engineering Units Profile............................................................................... 119
Create a User Engineering Units Profile .................................................................................. 120
Graphics Commands – An Overview ..................................................................................................... 120
Drawing Flowsheets in the Edit Flowsheet Mode..................................................................... 120
Graphics Features of the Plot Window..................................................................................... 121
Using the PFD Window ............................................................................................................ 121
The Edit Flowsheet Mode .................................................................................................................... 122
The Main Palette .................................................................................................................... 122
Sub-Palettes .................................................................................................................... 124
The Size and Shape of the Palette........................................................................................... 125
Hiding and Calling the Palette.................................................................................................. 125
Moving the Palettes.................................................................................................................. 126
Drawing With the Palette .................................................................................................................... 126
Drawing Lines .................................................................................................................... 126
Drawing Rectangles ................................................................................................................. 126
Drawing Ellipses .................................................................................................................... 127
Drawing Polylines .................................................................................................................... 127
Drawing Polygons .................................................................................................................... 127
Text .................................................................................................................... 128
How to Put Text on a Drawing................................................................................................................ 128
The Format Command .................................................................................................................... 128
Bring to Front .................................................................................................................... 129
Send to Back .................................................................................................................... 129
Fill Pattern .................................................................................................................... 130
Pen Style ....................................................................................................................130
Arrowheads .................................................................................................................... 130
Color .................................................................................................................... 130
Font .................................................................................................................... 131
Align .................................................................................................................... 131
Import Bitmap .................................................................................................................... 131
How to Rotate an Object Using the Palette ............................................................................................ 132
How to Move, Modify, Delete, or Flip Objects......................................................................................... 132
Moving a Single Object ............................................................................................................ 132
Moving Multiple Objects ........................................................................................................... 132
Panning the Flowsheet............................................................................................................. 133
Resizing ....................................................................................................................133
Deleting ....................................................................................................................133
Flipping an Object’s Y-Axis ...................................................................................................... 133
How to Copy to the Clipboard................................................................................................................. 133
Using the Metafile .................................................................................................................... 133
Using the Copy Command ....................................................................................................... 134
How to Generate a DXF File .................................................................................................................. 134
iv
How to Draw a Flowsheet .....................................................................................................................134
Step 1: Enter the Edit Flowsheet Mode ....................................................................................134
Step 2: Place Unitops on the Flowsheet...................................................................................136
Step 3: Connecting Unitops with Streams ................................................................................137
Step 4: Modifying and Adding to the Flowsheet .......................................................................138
How to Add Unitops to the Flowsheet.....................................................................................................138
Briefly .....................................................................................................................139
Details .....................................................................................................................139
Drawing Streams .....................................................................................................................140
Drawing Simple Streams (One or Less Direction Change).......................................................141
Drawing Complex Streams (Multiple Direction Changes).........................................................141
How to Select Components for the Component List ...............................................................................141
Calling the Component List Dialog Box ..................................................................................................142
Using the Component List Dialog Box ....................................................................................................142
Briefly .....................................................................................................................143
Details .....................................................................................................................143
How to Select K-Value Options ..............................................................................................................144
Briefly .....................................................................................................................145
Details .....................................................................................................................145
How to Select Enthalpy Options .............................................................................................................146
Briefly .....................................................................................................................146
Details .....................................................................................................................147
How to Define the Feed Streams............................................................................................................148
Briefly .....................................................................................................................148
Details .....................................................................................................................149
How to Specify Unit Operations ..............................................................................................................152
Calling a Unitop Dialog Box......................................................................................................152
Rules for Completing the Unitop Dialog Boxes.........................................................................152
Degrees of Freedom and Unitop Dialog Boxes ........................................................................152
How to Run Simulations in CHEMCAD Suite .........................................................................................153
Running Steady State Simulations ...........................................................................................153
How to Review Stream Compositions.....................................................................................................155
Selecting Streams ....................................................................................................................155
How to Set Flow Units for Results and Reports ......................................................................................156
How to View Stream Properties Using the Results Command ...............................................................157
Using the Properties Option Dialog Box ...................................................................................157
How to Plot .....................................................................................................................157
Plot Menu Options....................................................................................................................158
How to Create Reports .....................................................................................................................176
Calculate and Give Results ......................................................................................................177
Report Formats .....................................................................................................................177
Select Streams .....................................................................................................................178
Select Stream Properties..........................................................................................................180
Stream Flowrate/Composition ..................................................................................................181
Distillation Summaries ..............................................................................................................181
Heating Curves .....................................................................................................................182
v
Batch/Dynamic Results ............................................................................................................ 182
Miscellaneous .................................................................................................................... 183
End Report .................................................................................................................... 183
How to Create PFD’s .................................................................................................................... 184
Creating the Main PFD............................................................................................................. 184
Creating Secondary PFD’s....................................................................................................... 185
Opening and Editing Secondary PFD’s.................................................................................... 185
Adding a Stream Databox to the PFD .................................................................................................... 186
Step 1: Select the Streams to be Included in the Databox ....................................................... 187
Step 2: Complete the PFD Properties Options Dialog Box ...................................................... 187
Step 3: Complete the Databox Settings Dialog Box................................................................. 189
Step 4: Move and Stretch the Databox .................................................................................... 189
Adding a Unitop Databox to a PFD ........................................................................................................ 189
Step 1: Select the Unitops for Databox Generation.................................................................. 190
Step 2: Complete the Databox Settings Dialog Box................................................................. 190
Step 3: Move and Stretch the Databox .................................................................................... 190
Adding a TP Box to a PFD .................................................................................................................... 191
Select the Options to be Displayed .......................................................................................... 192
Select Streams from Flowsheet ............................................................................................... 193
Move the TP Boxes as Desired................................................................................................ 193
Running a Dynamics Simulation............................................................................................................. 193
The Steps for Setting Up a Dynamic Flowsheet....................................................................... 193
Starting a New Job................................................................................................................... 194
Selecting Engineering Units ..................................................................................................... 194
Draw the Flowsheet ................................................................................................................. 194
Make Sure the Dynamics Mode is Turned On ......................................................................... 195
Select Components.................................................................................................................. 196
Select Thermodynamic Options ............................................................................................... 196
Specify Feed Streams and Stream Initial Conditions ............................................................... 196
Specifying UnitOps................................................................................................................... 196
Specifying Runtimes, Time Steps, and/or Stop Criteria ........................................................... 196
Running the Dynamic Simulation ............................................................................................. 197
Re-Running and Extending the Run......................................................................................... 200
How to Run a Sensitivity Analysis .......................................................................................................... 201
Completing the Independent Variable Dialog Box.................................................................... 203
Completing the Dependent Variable Dialog Box ...................................................................... 204
Using Optimization in CHEMCAD .......................................................................................................... 204
How to Build User Added Symbols and Icons ........................................................................................ 209
Symbol Builder Palette .................................................................................................................... 210
Procedure for Building and Saving Unitop Icons .................................................................................... 211
User Added Palette Names .................................................................................................................... 213
vi
CHEMCAD Version 5.4 User’s Guide
Active Area
Title bar
Menu bar
Tool bar
Help line
The Menu Bar contains the commands for displaying menus that provide the user with access to
specific functions. These commands are:
File For printer page setup, opening jobs, and job management.
License For license configuration, dongle updates and special license authorization.
View For toggling the tool bar and the status bar on and off.
Help For using the on-line help system.
The Simulate Flowsheet Window is where a user creates, specifies, runs, and reviews a process
flowsheet. It is, therefore, where users spend most of their time. When you enter the Simulate
Flowsheet Window by creating a new job, your screen will look something like this:
15
User’s Guide CHEMCAD Version 5.4
Title bar
Active Area
Menu bar
Tool bar
Palette
Help line
This screen is organized similar to the Top Level screen described earlier, however, the active area is
now "active", (available to draw flowsheets), and a graphics palette has been added.
When you open an existing job, your screen will look something like this:
Notice that in the latter case, not only is a flowsheet present but the graphics palette is not present. This
is because the Simulate Flowsheet Window has two modes: the graphics mode and the simulation
mode. When you start a new job or flowsheet, CHEMCAD automatically starts you in Edit Flowsheet
(graphics) mode, which is only for drawing/editing flowsheets. When you open an existing job,
CHEMCAD automatically puts you in simulation mode, which is for specifying and running flowsheet
simulations. The window organization for both modes is the same, but some of the available commands
are different.
16
CHEMCAD Version 5.4 User’s Guide
The top line, called the Title Bar, now contains the CHEMCAD logo, the current version number, and the
current job name, as well as, the minimize, title, and close buttons which are always present on the left
side.
The Menu Bar follows the Title Bar as usual, but now there are fourteen commands in addition to the
Help command. These commands are:
File For file management and print control.
Edit For modifying various aspects of the flowsheet and its presentation.
Edit functions include Redraw, Undo, Redo, Cut, Copy, Paste,
Delete, Flip, and Rotate among others.
View For switching the toolbar, status bar, and palette on and off. Also
enables the user to make grid and palette settings.
Format For selecting engineering units and making graphics formatting
specifications
Run Simulation/ For switching between graphics and simulation mode.
Edit Flowsheet
ThermoPhysical For selecting components, making K-value, enthalpy and transport
property method selections, editing the databank, specifying solids
and editing BIPs.
Specifications For entering, editing, and manipulating stream and unit operations
input data. This may also be done by double clicking the stream or
UnitOp on the flowsheet directly.
Run For running the simulation and sensitivity studies, as well as for
defining numerical controls.
Results For viewing calculated results.
Plot For displaying calculated results graphically.
Output For preparing reports and Process Flow Diagrams (PFD’s).
Sizing For performing rating and sizing calculations for various types of
equipment.
Tools For performing various activities associated with simulation. These
include data regression, CO2 – solids and hydrates prediction,
TOD/COD calculations, and others.
Window For arranging windows and icons display.
Help For invoking the CHEMCAD Help and/or Coach system.
The Menu Bar is followed by the Tool Bar. The toolbar functions are explained in a later section of this
manual.
17
User’s Guide CHEMCAD Version 5.4
Below the Main Tool Bar is the Active Area. Notice that this area is accompanied by elevator bars for
scrolling the active area display up and down, and left and right.
If you are in Edit Flowsheet (graphics) mode, the Active Area will contain the Main Palette. The Main
Palette provides the primary tools for drawing the flowsheet. Its use is described in detail in later
sections of this Users Guide.
The bottom line of the current display is the Help line previously described.
THE PLOT WINDOW
CHEMCAD allows the user to create a wide range of plots. When a plot is created, CHEMCAD displays
it inside a Plot Window. The purpose of the Plot Window is to enable the user to embellish and/or edit
the plot before it is printed or filed. A Plot Window looks something like the window shown below.
Obviously the type and content of the plot varies with each situation, but the window is the same.
This window is similar to other graphics windows in CHEMCAD, and has the following commands
available:
File For printing, and opening and closing other jobs.
Edit Contains the Undo, Cut, Copy and Paste commands. Cut, copy and paste to the
clipboard.
View To toggle the Tool bar and Status bar on and off.
Graph To edit the plot display (text, color, pattern, etc.) and/or export the plot data to Excel.
Window For managing the various open windows.
Help To provide access to the graphics help system.
18
CHEMCAD Version 5.4 User’s Guide
Each plot automatically contains a program generated Title and Legend. The title is located at the top
of the plot and the legend is located at the bottom. Each may be edited using the Chart Explorer.
Selecting the Edit option on the Graph Menu accesses the Chart Explorer.
A brief description of the function and operation of each toolbar button of the Simulate Flowsheet
Window follows the button graphic:
Open Flowsheet button: Opens an existing flowsheet within the existing working directory.
Save Flowsheet button: Saves the currently open flowsheet to the currently specified jobname.
Cut button: Removes selected portions of the flowsheet and copies them to the clipboard.
Zoom percentage button: Selects the percentage to be used when zooming in and out.
Zoom Out button: Zooms out a specified percentage from the center of the flowsheet.
Zoom in at a point button: Zooms in a specified percentage on a user specified point of the
flowsheet.
Zoom out at a point button: Zooms out a specified percentage on a user specified point of the
flowsheet.
Zoom rectangle button: Zooms in on an area of the flowsheet indicated by a user drawn
rectangle.
Pan overview button: Opens and closes the Pan Overview window which enables the user to
pan the entire flowsheet.
19
User’s Guide CHEMCAD Version 5.4
Graphics palettes button: Opens and closes the main palette and all open sub-palettes while
the user is in the in the edit flowsheet mode.
Simulation/Graphics button: Switches back and forth between the edit flowsheet mode and
the simulation mode.
Define components button: Clicking this button calls forth the Component Selection dialog
box. This dialog box may be used to add, insert, or delete components from the current
component list.
K-Value options button: Selecting this option takes you directly into the K-value Options
dialog box. From there the user may select the K-value models and options to be used in the
simulation.
Enthalpy options button: Selecting this option takes you directly into the Enthalpy Options
dialog box. From there the user may select the enthalpy models and options to be used in the
simulation.
Edit feed streams button: Clicking this button will take the user directly into the View or Edit
Streams dialog box with the feed streams automatically selected. There the user can specify
or edit the feed stream(s) compositions and thermodynamic properties, as well as, perform
quick flash calculations.
Run All button: Clicking the Run All button will cause the program to simulate the entire
flowsheet.
Set run time button: Enables the user to specify the “simulated time” and the integration time
steps for a dynamic simulation.
Reset to Initial state button: To restore the original time zero conditions for a dynamic
flowsheet.
Run dynamic simulation button: Start a dynamics simulation from the initial state (time zero).
Plot dynamic streams button: Plot results of a dynamics simulation for a specified stream.
Plot dynamic UnitOp button: Plot results of a dynamics simulation for a specified UnitOp.
View all stream compositions button: View the results of all streams in the flowsheet
(for a steady state simulation).
View all stream properties button: View the properties of all streams in the flowsheet
(for a steady state simulation).
Component list button: Displays a list of the components currently selected for this flowsheet.
20
CHEMCAD Version 5.4 User’s Guide
To print in CHEMCAD, the user must display the report, plot, PFD, or flowsheet that he or she wants a
hardcopy of, then call the Print dialog box. Once the print parameters are accepted in this dialog box,
the print will be executed.
It should be noted that CHEMCAD displays all tabular output in Wordpad (if it is generated using the
Results command) or in Word (if it is generated using the Output command). As a result, to print output
of this nature, you must execute the Print command from within the active Word or Wordpad window.
Only graphical results or presentations are printed from within an active CHEMCAD window. Obviously,
the Print and the Print Preview dialog boxes are the same in CHEMCAD as they are in Word and
Wordpad.
BRIEFLY
1. Use the Results, Output, or Plot commands to produce a tabular report. Results output is
displayed in Wordpad; Output is displayed in Word; the tabular portion of Plot output is displayed in
Wordpad. CHEMCAD will leave the Word or Wordpad window active.
2. Click the Word or Wordpad Print button with the mouse.
3. The Print dialog box will appear. Check and edit the current print selections (if necessary) using
this dialog box. Then click [OK].
4. The report will print.
5. Close the Word or Wordpad window containing the report.
DETAILS
There are several ways to print in any Windows program. These are:
• Using the Print and Print Preview commands under the File menu.
• Using the Print button.
• Using the [CTRL + P] keys.
Method 1: Using the Print and Print Preview commands under the File menu.
The File menu contains the Print and Print Preview commands in its menu. To use
these commands follow the procedure given below.
Step 1: Use the Results, Output, or Plot commands to produce a report. Results
output is displayed in Wordpad; Output is displayed in Wordpad; the tabular
portion of Plot output is displayed in Wordpad. CHEMCAD will leave the
Word or Wordpad window active.
Step 2: Click the File menu.
21
User’s Guide CHEMCAD Version 5.4
Step 3: Select the Print option (from within Word or Wordpad) by clicking on it, or by
pressing the [P] key. The Print dialog box will appear.
Step 4: Review and edit the default selections as necessary. Then click [OK].
Step 5: After printing is complete, close the window containing the report.
The Print Preview command is selected in the same manner as the Print command.
The Print Preview command is used to preview the print job on the computer monitor
in a WYSIWYG (What You See Is What You Get) format.
Method 2: Using the Print button.
The Print button is a shortcut for selecting the Print command from the File menu.
Method 3: Using the [CTRL + P] keys.
[CTRL + P] works the same way as the Print button. The user presses the [CTRL] key and the [P] key
simultaneously.
Graphic output is printed using procedures very similar to those outlined above for tabular output. The
only difference is that the Print command is executed from within CHEMCAD itself.
BRIEFLY
1. Make sure that the window containing the graphical output or display that you want to print is active.
If you want to print the flowsheet, the Simulation Window should be active; if you want to print a
PFD, the PFD Window should be active; and if you want to print a plot, the Plot Window should be
active. (Note: When the Plot command is executed, it opens one or more plot windows and it
usually opens a Wordpad window containing a tabulation of the information plotted. CHEMCAD will
leave the Word or Wordpad window active.)
2. Click the CHEMCAD Print button with the mouse.
3. The Print dialog box will appear. Check and edit the current print selections (if necessary) using
this dialog box. Then click [OK].
4. The report will print.
DETAILS
There are several ways to print in any Windows program. These are:
• Using the Print and Print Preview commands under the File menu.
• Using the Print button.
• Using the [CTRL + P] keys.
22
CHEMCAD Version 5.4 User’s Guide
Method 1: Using the Print and Print Preview commands under the File menu.
The File menu contains the Print and Print Preview commands in its menu. To use
these commands follow the procedure given below.
Step 1: Make sure that the window containing the graphical output or display that you
want to print is active. If you want to print the flowsheet, the Simulation
Window should be active; if you want to print a PFD, the PFD Window
should be active; and if you want to print a plot, the Plot Window should be
active. (Note: When the Plot command is executed, it opens one or more
plot windows and it usually opens a Wordpad window containing a tabulation
of the information plotted. CHEMCAD will leave the Word or Wordpad
window active.)
Step 2: Click the File command on the CHEMCAD menu bar.
Step 3: Select the Print option by clicking on it, or by pressing the [P] key. The Print
dialog box will appear.
Step 4: Review and edit the default selections as necessary. Then click [OK].
Step 5: After printing is complete, close the window containing the report.
Method 2: Using the Print button.
The Print button is a shortcut for selecting the Print command from the File menu.
Method 3: Using the [CTRL + P] keys.
[CTRL + P] works the same way as the Print button. The user presses the [CTRL]
key and the [P] key simultaneously.
During the course of their work, CHEMCAD users may need to create, load, copy, delete and/or rename
various types of files associated with a particular job or project.
THE CHEMCAD FILE TYPES
2. Neutral file data – Neutral file data is physical properties data which is being imported into
CHEMCAD from some outside database. This is accomplished through use of a neutral file where
format is described in the on-line help manual.
These files must be stored in the subdirectory of the job for which they are being used.
WHERE FILES ARE STORED
Importing jobs is the process of copying a job directory from some location (normally a floppy device) to
the working directory.
The procedure for importing jobs is:
1. Select the File command from the menu bar. The File menu will open.
2. Click on the Import job option of the File menu.
CHEMCAD will be expecting to import the job from drive A:, so it will look there first. If the job is on
drive A:, the Select Job for Import dialog box will appear with drive A: as the current directory.
If the job is not there, or if there is no floppy in drive A:, the program will issue an appropriate
message and ask if the user wants to Cancel or Retry.
Clicking Retry will cause the program to look to drive A: again.
Clicking Cancel will open the Select Job for Import dialog box with the Windows Desktop as the
current directory.
3. Identify the job to be imported by clicking through the directory tree until the file <Jobname>. CCX
is displayed in the dialog box window. Then double click on <Jobname>. CCX. The SaveAs
dialog box will open.
4. Identify the name and location you want for this job by:
24
CHEMCAD Version 5.4 User’s Guide
(i) clicking through the directory tree until the destination directory is displayed in the Save in:
field of the SaveAs dialog box. The default working directory will already be entered in this
field, so no action may be required to complete this step.
(ii) typing the desired jobname in the File name: field of the SaveAs dialog box; then
(iii) clicking on the Save button.
All files associated with the imported job will be transferred to the specified location and directory.
EXPORTING JOBS
Exporting jobs is the process of copying a job directory from the default working directory to some other
location. Exporting is similar to the process importing jobs except that the direction (and therefore the
default locations) are different.
The procedure for exporting jobs is:
1. Select the File command from the menu bar. Click on the Export Job command on the File menu.
The Export Job dialog box will open.
2. Click the Find Job for copying button. The Select Job for Export dialog box will open. The
browser window opens to the current work directory (c:\cc5data by default).
3. Identify the job to be exported by scrolling through the browser window until the folder for the job is
found.
4. Double click on the folder for the job, and then double click on the index file <jobname>.ccx. The
Select Job dialog closes, and returns the user to the Export Job dialog.
5. Click the Locate Target Directory button. The Browse for Folder dialog box appears.
6. Select the location that the job is to be exported to using the Browse for Folder dialog box. When
the destination folder is highlighted, click [OK]. The job will be copied to that folder (directory)
under the same name.
SAVE AS CASE
The Save As Case command makes a copy of the current job and saves it under a new name in the
current job directory. This function enables the user to keep track of separate case studies of the same
basic job.
The Save As Case command is located on the File menu.
USING HELP
25
User’s Guide CHEMCAD Version 5.4
Click the Find tab to search for words or phrases that may be contained in a Help topic.
2. If your Help file doesn’t have a Contents tab, click the Contents button to see a list of topics.
Tip: For more information about the items on each tab, click ? at the top of the dialog
box, and then click the item.
Tip: If you want to print or copy the information in a pop-up window, use the right
mouse button to click inside it, and then click Print topic.
Another way to get Help on an item on the screen is to use your right mouse
button to click the area you want help on, and then click the What’ This?
command.
1. In the Help topic window, click the Edit menu or the Options button, and then click Copy. You
can also use the right mouse button to click inside the topic or pop-up window.
2. In the document where you want the information to appear, click the place where you want to put
the information.
3. On the Edit menu, click Paste.
Tip: If you want to copy only part of a topic, select the part you want to copy before you
click the Copy command.
1. In the Help topic you want to print, click the Print button or the Option button, and then click Print
Topic. You can also use your right mouse button to click inside the Help window, and then click
Print Topic.
Tip: You can print a group of related topics by clicking a book in the Help Contents
and then click Print.
To print the Help in a pop-up window, use your right mouse button to click inside
the pop-up window, and then click Print Topic.
26
CHEMCAD Version 5.4 User’s Guide
1. In the Help Topic window, click Options, and then click Display History window.
2. If your Help Topic does not have a Display History window command, you cannot view the
History window.
Tip: If your Help window has a Back button, you can click it to view topics you’ve seen
before.
1. In Help, click the Search tab to find words or phrases in the Help topics.
2. Type the word or phrase that you wish to find in the first field.
3. The second field displays additional words to help you narrow your search.
4. The third field displays the list of topics that were found in the search.
Tip: For Help on an item, click on the field containing that item and press the [F1] key.
If you decide you want different features, you can recreate the word list by clicking
Rebuild.
1. In Help, click the Find tab, and then click the Search menu’s Options command.
2. Select the search options that you prefer to use.
3. If an option is unavailable, use the Search menu’s Rebuild command.
Note: The text of each topic found contains the word(s) you looked for, even if the word(s) are
not in the topic title.
Tip: If you want to look for more than one word, separate them with spaces in the first
text box.
When you look for hyphenated words, be sure to type the hyphen.
To set specific search criteria, click Options.
27
User’s Guide CHEMCAD Version 5.4
CHEMCAD is a very easy program to learn, and the best way to master it is by using it. This tutorial
provides basic input skills for operating CC-STEADY STATE. The CHEMCAD input convention and
rules apply to CC-STEADY STATE. Since CC-STEADY STATE is a module of CHEMCAD, the names
will be used interchangeably in this tutorial. Here we provide a step-by-step description of how to solve
the condensate stabilizer problem given below. The input procedure is simple and straightforward. It is
designed to be intuitive for a chemical engineer familiar with the Windows environment. However, for
the sake of clarity and for those new to Windows, a review of some of the basic rules for using
CHEMCAD is given.
The following ten basic steps are used to run a flowsheet simulation in CHEMCAD.
• Starting a new job
• Selecting engineering units
• Creating a flowsheet
• Selecting components
• Selecting thermodynamics options
• Defining the feed streams
• Input equipment parameters
• Running the simulation
• Reviewing the results
• Generating hardcopy output
The steps do not have to be performed in this order nor do all of them have to be done for each
flowsheet. All should be considered for each problem.
There are a series of Help facilities available throughout the program. The bottom line of the screen
provides a one-sentence description of the current highlighted item. The Help command provides
access to the On-line Manual which contains comprehensive technical information. The [F1] key
provides context sensitive help (place the cursor in a specific field and press the [F1] key). The Coach
facility will provide instructions on how to perform selected tasks. Use of these help facilities will ease
your way through the program.
CHEMCAD is object oriented. Therefore, most input and editing can be done by double clicking or right
clicking the object of the operation, as well as by using the menu commands.
28
CHEMCAD Version 5.4 User’s Guide
All stream and unit operations specifications (input) are accomplished using dialog boxes. These dialog
boxes are context specific and employ some combination of character fields, combo boxes, choice
boxes and check boxes.
The mouse is a very easy to use way to get the computer to do what you want. CHEMCAD, like many
Windows program, requires the use of a mouse, trackball, or similar pointing device with both a primary
and secondary button (i.e. a standard Microsoft 2-button mouse). The basic Mouse techniques are
summarized below:
Click To press and release the primary mouse button (normally the left
button).
Right-click To press and release the secondary mouse button (normally the right
button).
Double-click To press the primary button twice in rapid succession.
Drag To press and hold down the primary mouse button while moving the
mouse.
Point To move the mouse arrow until it touches the item of choice.
Right-click hold Point to a specific area, then click and hold the secondary mouse
button.
• The [TAB] key is used to move to the next field on a data entry dialog box.
• The [PgUp] and [PgDn] keys may be used to “page” or scroll through lists.
• Holding down the [SHIFT + TAB] will cause the program to move back or up one field.
• The [F1] key is used to call context specific help.
• The [F5] key is used to display the current job’s component list from within a dialog box.
• The [F6] key is used for engineering units conversion.
• The [F7] key calls a simple calculator.
The “Standard” way of executing commands in CHEMCAD is to click a command on the Menu Bar and
follow that command down through the subsequent menus until the desired function is reached. Thus, to
29
User’s Guide CHEMCAD Version 5.4
select components from the databank, one would first click the command ThermoPhysical on the
Simulation Menu Bar; click the option Component List from the ThermoPhysical Menu and finally
select components from the Component Selection dialog box.
There is a shorter way of reaching this and other frequently used functions. This is to use the
CHEMCAD Power buttons, which are located on the tool bar. This tool bar is toggled on and off using
the View/Toolbar command.
The problem to be solved in this tutorial is illustrated in Figure 1 below. It is a condensate stabilizer
plant. Gas enters the system with the feed conditions shown. It is our job to take this existing unit and
determine new operating conditions and any necessary modifications. The design requirements are as
follows:
1. The cricondentherm (highest possible) dewpoint of the product gas must be 20° F or less.
2. The stabilized condensate (Stream 9) must have maximum propane content of 1%.
Figure 1
Condensate Stabilizer
HX-1 HX-2 Valve Stabilizer
P drop 1 = 5 psi P drop = 5 psi P out = 125 psia 12 stages
P drop 2 = 5 psi T out = -5 F Feed stage =1
Vap. Frac. (1) = 1.0 Bottom draw = 30 lb-moles/hr
Column P drop = 5 psi
Feed:
T = 75. F
P = 200. psia
N2 = 100.19 lb-mol/hr 1% propane
C1 = 4505.48
C2 = 514.00
C3 = 214.00
iC4 = 19.20
nC4 = 18.18 Cricondentherm
iC5 = 26.40 dewpoint = 20 °F
nC5 = 14.00
nC6 = 14.00
GETTING STARTED
The first time you run CHEMCAD the Top Level Window will appear on your screen. Please maximize
this window (that is, zoom it to fill in the screen) by clicking the Maximize button in the upper right hand
30
CHEMCAD Version 5.4 User’s Guide
corner of the CHEMCAD window. This will cause CHEMCAD to fill your screen and your display should
look something like this:
Close Button
Tile
Minimize Button
The top line is called the Title Bar. It contains the CHEMCAD logo and name on the left side, and the
WINDOWS minimize, tile, and close buttons on the right side.
The next line is called the Menu Bar. This bar contains the top-level commands for CHEMCAD. They
are:
File This command is used to define output formats, open jobs,
print, and obtain general information about CHEMCAD.
License This command is used to configure license, update dongles,
and authorize special licenses.
View This command enables the user to toggle the Tool bar and
Status bar on and off.
Help This function allows the user to call the on-line Help facility.
The third line (or bar) is called the Tool Bar. It contains the symbols to directly invoke short cuts to
various file functions that would otherwise be accessed through the menus.
The remainder of the window is inactive at this level.
The current window displays only the top-level of CHEMCAD. CHEMCAD also has other windows for
setting up and running a simulation, generating PFD’s, creating and editing plots, etc. In the course of
this tutorial, you will be introduced to these windows and their use.
31
User’s Guide CHEMCAD Version 5.4
Let’s start by opening a new job and giving it a job name. The File command is used for this. To open
the File menu, click on the word File on the menu bar.
Now choose the New Job option by clicking on it.
The following dialog box will open:
This dialog box is prompting you to enter a name and folder for the new job. Let’s use the name
TUTOR1. Please enter this name in the field labeled File Name. Then close the dialog box by clicking
the [Save] button. You will be taken into the main working window of CHEMCAD.
The major features of this window are labeled above as described below:
32
CHEMCAD Version 5.4 User’s Guide
Title Bar
Palette Tool Bar Menu Bar
Active Area
The top line, called the Title Bar, now contains the CHEMCAD logo and the current job name, as well
as, the minimize, title, and close buttons which are always present on the left side.
The Menu Bar follows the Title Bar and consists of fifteen commands. These commands are:
File For file management and print control.
Edit For modifying various aspects of the flowsheet and its
presentation. Edit functions include Redraw, Undo, Redo,
Cut, Copy, Paste, Delete, Flip, and Rotate 90° among
others.
View For controlling various display and drawing options.
Format For selecting engineering units, setting graphics options,
and importing bit maps.
Run Simulation/Edit To switch back and forth between the Edit Flowsheet mode
Flowsheet and the Run Simulation mode.
ThermoPhysical For selecting components, K-Value method(s), and enthalpy
method(s) for the current job, as well as, viewing and editing
the CHEMCAD databanks; setting up distillation curves and
defining solids.
33
User’s Guide CHEMCAD Version 5.4
The Menu Bar is followed by the Tool Bar. The toolbar contains “power buttons” or short cuts to
specific frequently used functions. These toolbar functions are explained in an earlier section of this
guide.
Below the Tool Bar is the Active Area. Notice that this area is accompanied by elevator bars for
scrolling the active area display up and down, and left and right. Because we have not yet drawn
our flowsheet, the Active Area is now blank except for the Main Palette.
The Main Palette provides access to the graphics functions and symbols that are necessary for the
creation of the flowsheet.
To select engineering units for this flowsheet, select the Format command by clicking it with the mouse.
The following menu will appear:
34
CHEMCAD Version 5.4 User’s Guide
Now select the Eng Units option by clicking on it with the mouse. The following dialog box will appear:
The ENGLISH units option is the default and is currently highlighted. You may change the engineering
units system by clicking any one of the four buttons English, Alt SI, SI, or Metric, or you can change any
unit individually by clicking on the individual item and then selecting from the list presented. For this
tutorial we will use English engineering units, therefore just exit the dialog box by clicking the Cancel
button.
To draw the flowsheet you will be working with the flowsheet palette, which looks like this:
35
User’s Guide CHEMCAD Version 5.4
36
CHEMCAD Version 5.4 User’s Guide
• The size and shape of the main palette can be controlled using the View\Palette Settings
commands.
• On the icon display, inlets are indicated by small blue squares and outlets by small red squares.
Our purpose now is to set up the flowsheet topology. Creating a flowsheet is the process of placing unit
operations icons on the screen, connecting them with streams, and then adding various graphical
objects to enhance the drawing. All of these things may be done using the palette.
We will start by placing unit operations icons on the flowsheet. By convention, CHEMCAD requires that
every stream come from a unit operation and go to a unit operation. Therefore, we must place a Feed
icon on the flowsheet to serve as the “source” unit for the feed stream. This is a good place to start by
pointing to the Feed box:
Feed
37
User’s Guide CHEMCAD Version 5.4
• With the left mouse button held down, drag the icon up about one-inch, then release the
left button of the mouse. The icon position has been changed.
b. It may be necessary to move the palette out of the way in order to have access to the icon. You
can do this by clicking and dragging on the red bar at the top of the palette.
c. To view the object editing options: place the mouse arrow on the icon (on the flowsheet, not on
the palette) and press the right button on the mouse.
d. To move or stretch an object: left click on the icon so that the four object boxes are displayed
around the icon. Then click and drag on one of these boxes. The icon will grow or shrink
according to the mouse movements.
Now let’s place the two heat exchangers on the flowsheet. Please follow the procedure given below:
1. Point to the heat exchanger tile and let the cursor stay there until the message label appears. Using
this label, make sure you are pointing to the heat exchanger box.
2. Right click the box. The heat exchanger icon sub-palette should appear.
3. Now point to the two sided heat exchanger icon as indicated below:
Two-sided heat
exchanger
4. Left click on this icon. The palettes will disappear and the small, square cursor will reappear.
5. Locate the cursor about one inch directly to the right of the feed icon. Then left click again. The
heat exchanger icon will be displayed on the flowsheet and the main palette (only) will reappear.
6. Now point to the heat exchanger tile again. This time we want a single sided heat exchanger such
as the one shown on the main palette. Therefore, we do not need to call the sub-palette again.
7. Left click on this icon. The palette will disappear and the small, square cursor will reappear.
38
CHEMCAD Version 5.4 User’s Guide
8. Locate the cursor about one inch directly to the right of the first heat exchanger icon. Then left click
again. The heat exchanger icon will be displayed on the flowsheet and the palette will reappear.
For convenience, move the palette to one side by clicking and dragging on the brown bar at the top of
the palette. Now follow the procedure outlined above to place the flash tank and the valve unit
operations on the screen:
39
User’s Guide CHEMCAD Version 5.4
For the condensate stabilizer itself we want to use a distillation column module. You might notice from
the palette that there are multiple distillation modules available in CC-STEADY STATE. An explanation
of each of these options is given in the on-line Help manual. You can access this manual at any time by
clicking the Help command on the menu bar. For now however, let’s accept that the module we want to
use is the rigorous distillation model called Tower. This UnitOp is found on your palette as shown below:
Since we want to use a Tower icon that has a reboiler but no condenser we must use the sub-palette to
select the desired icon. Therefore, right click on the Tower icon box. The sub-palette will appear.
Select the Tower icon indicated below by left clicking on it.
40
CHEMCAD Version 5.4 User’s Guide
Finally, we must put three Product icons on the flowsheet, one for each product stream. The Product
icon is located slightly to the right and down from the center of the palette as shown:
41
User’s Guide CHEMCAD Version 5.4
When you are finished, you screen should look similar to this:
It’s now time to connect the UnitOps with streams. To do this, click the Streams icon box on the main
palette.
42
CHEMCAD Version 5.4 User’s Guide
There are a few general rules to remember when we are drawing streams on the flowsheet:
1. Each stream goes from a source unit to a destination unit.
2. Each unit has inlet and outlet positions. These are established when the symbol is created. The
program always snaps streams to these positions. During the simulation, a process stream always
flows from an outlet position on a source unit to an inlet position on a destination unit, but when
drawing the flowsheet a stream may be drawn in any direction; that is; from an inlet position to an
outlet position as well as from an outlet position to an inlet position.
3. When starting a stream, the cursor will be a small cross. When the cursor gets near an inlet or
outlet position, it will convert to a black arrow. When this occurs you should left click the mouse to
start the stream if that is the starting position you desire.
4. When completing the stream to a unit, the cursor will remain as a black arrow. When the cursor is
near an inlet or outlet position, a label will appear indicating the location and number of the position.
5. Once the desired position has been located (as indicated by the appearance of the label), you
should left click the mouse to complete the stream.
6. While drawing a stream, the palette will disappear. It will reappear only when you left click
somewhere on the flowsheet which is not a UnitOp inlet or outlet point. You are not required to click
the stream (link) icon tile each time you begin a stream.
7. You can alternate between placing UnitOps on the screen and connecting them with streams as
long as the above rules are followed.
8. The first time you change directions of a stream, CHEMCAD will let you do so without any problem.
Every additional time you change directions, you must first press the left button on the mouse to
identify the longitude or latitude through which you want the stream to pass. Doing this will create
an anchor point to fix the longitude or latitude on the screen.
9. You may cancel the stream drawing action by double clicking the left button during the stream
drawing process.
With these rules in mind, let us now connect the UnitOps with streams.
Click the Streams icon box on the palette. The palette will disappear and the crosshairs cursor will
appear. Move the cursor close to the tip of the feed arrow. When the cursor switches to a black arrow,
press the left button on the mouse. Draw the stream over to the right with your mouse. When the label
for left-most inlet arrow on the first heat exchanger appears, press the left button on the mouse.
CHEMCAD will draw the stream directly to that point and will place a stream ID number on the flowsheet.
CHEMCAD issues ID numbers sequentially, so this ID will be Number 1. You may change it using the
EDIT STREAM menu (invoked by right clicking the stream) if you would like to do so.
Let’s draw the second stream. Move the cursor to the right-most point of the first heat exchanger. When
you are close enough to the unit outlet point, the cursor will switch over to the black arrow again. Press
the left button on the mouse. Draw the stream over to the inlet position on the second heat exchanger
and, when the label appears, press the left button on the mouse again. This should complete Stream 2.
Next, let’s draw the stream from the second heat exchanger to the flash tank. Locate the right most
outlet point on the Heat Exchanger unit. When the black arrow appears, click the left mouse button.
43
User’s Guide CHEMCAD Version 5.4
Now, draw the stream over to the flash tank until the first inlet label appears. Press the left button on the
mouse to complete Stream 3.
Let’s draw Stream 4 from the top of the flash tank. Move the cursor near the top of the flash tank until
the black arrow appears. Press the left button on the mouse. Now, draw the stream up about an inch
and over to the left until it is directly over the first heat exchanger, then try to draw the stream down. You
will notice you cannot do it; the entire line moves down with you. What we need to do is fix horizontal
latitude to which that line is pegged before we make our turn. To do this, select your horizontal elevation
for your cross-stream and press the left button on the mouse. Now, draw the steam down to the top of
the heat exchanger. When that inlet label appears, press the left button on the mouse.
Using this procedure, complete the rest of the streams until your flowsheet looks like this:
If you need to delete or reroute a stream, right click on the stream to call the Edit Stream menu. Use the
Delete and Re-draw commands as needed.
When all streams are satisfactorily drawn, click on a vacant spot on the flowsheet, and the palette will
reappear.
We are now finished drawing our flowsheet. To move on we need to activate the Simulation mode.
Therefore, at this time click on the Run Simulation command on the menu bar (or the S/G power button).
The palette will close, and the input functions will become available.
SELECTING COMPONENTS
Next let’s identify which components are to be used in this simulation. Selecting the ThermoPhysical
command does this. This may be done by pressing [ALT + L] or by clicking with the mouse. Do this now
please. The following menu will open up:
44
CHEMCAD Version 5.4 User’s Guide
To choose components from the standard CHEMCAD databank, click the Component List option with
the mouse. The following Component Selection dialog box will appear. This dialog box is organized as
indicated below:
Insert button
Add button
Clear button
Delete button
Next button
"Selected Components" area: The current list of selected components will be displayed in this area.
"Component Databank" area: All components stored in the databank(s) are listed here. Components
are listed in order of their ID numbers. When this area is active, a blue highlight will identify one of
the components.
Insert button: This button is used to insert a component somewhere in the component list, rather than
appending to the end of the list.
Add button: Clicking on the Add button will add the currently highlighted component to the end of the
flowsheet component list. Components may also be selected by double clicking on them. The
selected component will appear in the list displayed in the Selected Components Area.
45
User’s Guide CHEMCAD Version 5.4
Clear button: The Clear button is used to delete the entire component list. When this button is clicked,
all of the components listed in the Selected Components Area will be erased.
Delete button: The Delete button is used to delete individual components from the component list. To
use this option, highlight the component in the Selected Components Area and click the Delete
button.
Selection string field: This field is used to locate a component in the databank. Once the desired
component has been located, it is added to the flowsheet component list by double clicking on it or
by highlighting it and then clicking on the Add button. The program locates components by
matching the string entered in this field. The string can be any alphanumeric combination. The
string will be matched to any part of an ID numbers, formula, or synonym (component name) listed
in the databank.
As you type in the string, the program automatically finds and highlights the closest match. As the
string changes, the highlighted component changes.
Next button: If the current match is not the component you are looking for, click the Next button to find
the next matching string.
Copy Components from another job: The Copy Components button is used to import the component
list from another CHEMCAD job. When this button is clicked, the user is prompted to browse for
the location of the CHEMCAD job from which the components will be imported. These components
are the added to the Selected Components Area.
To show how a component is selected, let’s select Nitrogen. First, click on the Selection String Field,
then type in the string "Nitrogen". As you build the string, the program will locate and highlight the
component nitrogen. To add it to the component list, double click on it or click on the Add button. The
component will appear in the Selected Components Area.
Nitrogen could just as easily been located by entering the string "N2" in the field. The same thing could
have been done with the string "46" which is the ID number for nitrogen. Strings, which comprise only
part of the word, number, or formula, can also be used. It is also possible to highlight the desired
component by clicking on it directly and then clicking the Add button.
Now select the remaining components in the component list. Remember, if the first search does not
locate the desired component, click the Next button to find the next matching string. Now find the
following components and add them to the component list:
2 Methane
3 Ethane
4 Propane
5 I-butane
6 N-butane
7 I-pentane
8 N-pentane
10 N-hexane
46
CHEMCAD Version 5.4 User’s Guide
Let’s now save our list by clicking the [OK] button. The ThermoWizard will appear.
After the user first selects components the ThermoWizard will appear. The ThermoWizard is a system
available in the CHEMCAD Suite to assist the user in making K-value and enthalpy choices.
Selecting thermodynamic options basically means selecting a model or method for calculating vapor-
liquid (or vapor-liquid-liquid) phase equilibrium (called the K-value option) and selecting a method or
model for calculating the heat balance (called the enthalpy option). You do this using the
ThermoPhysical command located on the menu bar. This is the same command you used to access
the Component List above. Please click this option now. The ThermoPhysical menu should appear
as before.
47
User’s Guide CHEMCAD Version 5.4
CHEMCAD has a library of about 50 K-value models with a variety of options, and about twelve enthalpy
models. Making the proper selection from these libraries can sometimes be difficult. The issues
involved and the proper techniques for selection are described in the Thermodynamics section of the
on-line manual.
Because the issues involved in making thermodynamic selections and in using the Thermo Wizard are
beyond the scope of this tutorial, let’s assume we know that we want to use the Peng-Robinson method
for both the K-value and enthalpy calculations. In this case, we would proceed as given below.
First, we need to accept the default temperature/pressure values for the ThermoWizard,. The Wizard
will recommend using SRK, please accept this message box. Then let us now make our own selection in
the K-value Options dialog box. In the upper-left corner of this screen will be a combo box labeled
Global K-value Option, which is currently highlighted. Please open this window by clicking on it.
You will notice the presence of a Scroll Bar at the right of this list indicating that all of the available
options could not fit into this area. Therefore, the user may scroll through them using any of the methods
previously described in this tutorial. We would like to use the Peng-Robinson method. To make this
choice, please scroll up through list; point the arrow to the Peng-Robinson option; and click the left
button on the mouse. The box will close and Peng-Robinson will now be displayed in the field. Your
screen should look like this:
The other options on this screen are not important to us at this time. Therefore, let’s save our selection
by pointing and clicking the [OK] button in the lower right corner. This will return you to the Simulation
Menu Bar.
Now, let’s select our enthalpy model. Do this by again clicking the ThermoPhysical command, then
clicking the Enthalpy option. The Enthalpy Options dialog box will be displayed. You will notice on
this screen that the Peng-Robinson method has already been chosen. The program automatically
makes this the enthalpy model when you choose the Peng-Robinson K-value method. If this assumption
is erroneous, you may override it at any time. In our case, we would like to use the Peng-Robinson
model, so let’s point and click on the [OK] button in the lower right portion of the screen. This will close
the Enthalpy Options dialog box, saving the currently displayed options.
For the purpose of our tutorial, the thermodynamic selections are now complete.
48
CHEMCAD Version 5.4 User’s Guide
We are now in a position to define the feed streams. This can be done by using the Specifications
command on the menu bar or by double clicking directly on the stream we wish to specify. Double
clicking directly on the stream is obviously simpler, so let’s do that now. Double click stream 1. The Edit
Streams dialog box will appear like this:
49
User’s Guide CHEMCAD Version 5.4
• The fields Total Flow Units and Comp Units work together to provide the user with a variety of
ways to define stream compositions. If the Comp Units are set to mole, mass, or volume
fraction (which can be done globally or locally) then the Total Flow Units combo box will
become available. If Comp Units is set as a flow or amount option, then the total flowrate
becomes the sum of the component flowrates and the Total Flow Units combo box will not be
available for editing.
• If the Comp Units is set to an amount flow unit (as opposed to mole, mass, or volume fractions),
then as the component flowrate values are entered, they are automatically summed and the
current sum is displayed in the field labeled Total Flow.
• In the upper left hand corner of the dialog box is the Flash button. Clicking this button at
anytime will cause the program to perform a flash calculation using the currently specified
composition and thermodynamic properties. This allows quick flash calculations to be made
without exiting the dialog box.
• Fractions that do not sum to 1.0 are automatically normalized upon flashing or exiting the dialog
box.
Now, let’s enter the data. Let’s start with temperature. Please move to the temperature field by clicking
on it.
Once the highlight is on the proper field, type 75 [down arrow]. When you press the [down arrow] key,
the highlight will move down to the pressure field. Please enter 200 in this field.
Next, let’s move down to the Nitrogen field. Please move the cursor down until it points to the field to
the right of Nitrogen, and click the left button on the mouse. Please enter 100.19 in this field.
In a similar fashion, please enter the following numbers in their corresponding fields:
Methane 4505.48
Ethane 514
Propane 214
I-butane 19.2
N-butane 18.18
I-pentane 26.4
N-pentane 14
N-hexane 14
Save this stream information by pointing to the [OK] button in the upper-left corner of the dialog box. We
are now ready to input the equipment parameters.
50
CHEMCAD Version 5.4 User’s Guide
latter is easier, therefore, please point and double click on the first heat exchanger now. An equipment-
specific input dialog box will appear:
Data entry screens can be more than one page long. The buttons called Specifications, Misc. Settings,
and Cost Estimations indicate the pages for this dialog box. You may browse through them by clicking
on the tab.
NOW, LET’S FILL IN THE SCREEN
Pressure drop for both sides of the exchanger is 5 psi; therefore, click on the "Stream 1" pressure drop
field and press the 5 key, then click on the other pressure drop field which is labeled Stream 4. Likewise,
enter 5 in this field.
We need to specify the first stream outlet to be at its dewpoint. We do this by specifying an outlet vapor
fraction of 1. Therefore, move to the Vapor Fraction stream 2 field either by tabbing down to it or by
clicking on it. Then enter 1.
This completes the input for this unit. We now need to save this information and close the dialog box.
You do this by clicking on the [OK] button.
Specifying the second heat exchanger…
We can now select the next unit for data input. Move the cursor to the second heat exchanger and
double click. The menu for a single-sided heat exchanger will appear.
51
User’s Guide CHEMCAD Version 5.4
The outlet temperature from this heat exchanger will determine how much of the liquid is removed in the
flash drum. This, in turn, will determine the cricondentherm dewpoint of the product gas. Therefore, this
specification is one of the key parameters of our design. As a first attempt, let’s estimate an outlet
temperature of -5º F. Therefore, please enter 5 in the Pressure Drop field and a –5 in the Temperature
of Stream 3 field. Point and click on the [OK] button to save the data and close the dialog box.
Specifying the flash drum…
In our example, the flash drum is a vapor liquid separator and requires no specification. Therefore, we
do not need to enter any input for this unit.
Specifying the valve…
Let’s enter the outlet pressure for the valve. Please move the cursor to the valve and double click. The
Valve dialog box will appear. Since our outlet pressure for this unit is 125 psia, please enter 125 in the
Pressure Out field, then point and click on the [OK] button. This completes the input for the valve unit.
Specifying the stabilizer tower…
Now double click the tower unit. The TOWR Distillation Column dialog box will appear. There are five
pages to this screen as indicated by the tabs.
On the first page, we need to enter the top pressure, which is 125 psia; the column pressure drop, which
is 5 psi; the number of stages, which is 12, and the feed stage location, which is stage number 1.
Therefore, please complete your screen as shown below:
52
CHEMCAD Version 5.4 User’s Guide
Let’s continue our data input on the next page. Please click on the Specifications tab. We make our
specifications for the column on this screen. We have no condenser or side streams on this column so
we will only be making specifications for the reboiler.
First, we need to specify our reboiler mode. In order to determine what our options are, please point the
arrow to the field below the label Select Reboiler Mode and click the left button on the mouse. A list
should open displaying the available options.
We need to specify the bottom flowrate for this unit, which is Mode No. 4. Therefore, please point the
cursor to 4 Bottom mole flowrate and click the left button on the mouse. The list will close and the field
should now read 4 Bottom mole flowrate.
Now we need to specify the numeric value of that flowrate. This is done in the field immediately to the
right, which opens after we make our mode selection. Please point the arrow to that field, and click the
left button on the mouse. This field should be highlighted and we can enter a value of 30.
Now, let’s move to the next page of this dialogue box by clicking the Convergence tab. As you can see
from the screen, all of the entries on this page are optional. However, for the purpose of demonstration,
let’s enter an estimate of 50º F for the top temperature and 150º F for the bottom temperature. Please
point and click on the T top field and enter a value of 50 in this field. Now move to the field labeled T
bottom immediately below. Enter a value of 150 in this field.
Now we have completed the data input for the tower unit. Let’s save this data by pointing and clicking on
the [OK] button. When you do this, you will get a warning message saying you have not entered an
estimate for the distillate rate. The program will ask you if you want to ignore this warning. Warning
messages are for your information and can normally be ignored; therefore, please click [YES] now. This
will return you to the Simulation Window. All of the data entry for the flowsheet is now complete.
53
User’s Guide CHEMCAD Version 5.4
To run the simulation, point and click on the RUN command on the menu bar. This will cause the RUN
Menu to open up like this:
We want to run a steady state analysis, so select the Run All option.
The program will first recheck the data and list any errors and/or warnings on the screen. In this case,
we should have no errors, although we will have warnings saying we have not given certain estimates.
We can ignore these warnings and proceed by clicking the [YES] button. The calculation will then
proceed.
Upon finishing, the CC5 Message Box will appear with the message “Recycle calculation has
converged”. To close this dialog box and clear the screen, you must click on the [OK] button.
Now that the simulation is complete, we will want to review the results before printing a hardcopy. We
do this using the Results and Plot commands on the menu bar. With these commands, let’s check
whether we have met our design criteria.
Checking the cricondentherm dewpoint…
If we have chosen the proper outlet temperature for heat exchanger number 2, the cricondentherm
dewpoint for the product gas stream (Stream 5) will be 20º F or less. The cricondentherm dewpoint, you
will remember, is the highest dewpoint temperature a mixture will ever see at any pressure. The
simplest way for us to identify the highest dewpoint temperature of the product gas is to plot all of the
dewpoint temperatures of the product gas, i.e., to plot a phase envelope. Let’s do that now.
To plot anything inside CHEMCAD, we must start with the Plot command on the menu bar. Please
select this option by clicking on it. When you do this, the PLOT MENU will appear. On this menu, you
will see a list of the general categories of plots available within CHEMCAD. Please select Envelopes by
clicking on it.
54
CHEMCAD Version 5.4 User’s Guide
The Select streams dialog box will appear. Move the cursor to stream 5 (the product gas stream
leaving the bottom of heat exchanger number 1) and click it once. The number 5 will appear in the
dialog box field. Now click [OK] to close the streams selection process. The Phase Envelope Options
dialog box will appear.
No entries on this screen are required since we only need to look at the dew point line. However, to
make the plot more interesting, let’s display the 0.25 and the 0.5 vapor fraction lines in addition to the
normal phase envelope boundaries. Therefore, complete the dialog box as shown:
55
User’s Guide CHEMCAD Version 5.4
CHEMCAD will perform the required flash calculations necessary to generate the phase envelope as
specified above. Phase envelope results are produced in two formats:
1. A numerical tabulation (table) of the temperature, pressure, vapor fraction, vapor compressibility
factor, and the liquid compressibility factor.
2. A plot of temperature and pressure for each vapor fraction line requested.
The former is displayed in a WordPad Window; the latter in a Plot Window.
Since we are not going to use the tabulated results, please close the WordPad Window now. Your
screen will then look like this:
You are now in a plot window, and your available commands have changed. Actually, this window can
be thought of as a plot edit window because it is the same for every plot. It has the following commands:
File This command is for file management and print control as it is
in every CHEMCAD window.
Edit Contains the undo, cut, copy and paste commands.
View Controls the Toolbar and Status Bar display status.
Graph Provides access to zoom, edit and plot data transfer facilities.
Window For arranging windows and icons.
Help Provides access to the on-line help facility.
At this point, let’s make note of a few important items regarding CHEMCAD plots.
1. To zoom in on a certain section of the plot, point to one corner of the area that you want to zoom in
on, then click-and-drag (i.e., hold down the left mouse button while you are moving the cursor) to the
opposite corner of that area. When you release the mouse button, the program will zoom in on the
56
CHEMCAD Version 5.4 User’s Guide
boxed in area. To restore the original size, click on the Graph command (on the menu bar); then
click on the Zoom Out command.
2. The plot title text (in this case, Phase Envelope for Stream 5) can be edited using the Graph/Edit
titles command.
3. The color, size, layout and various other aspects of the plot presentation can be edited using the
Chart Explorer function.
4. A hardcopy of this plot can be obtained by clicking the Print button.
Let’s use some of these features to see how they work. First, remembering that we are trying to
determine if the cricondentherm dewpoint of Stream 5 is 20º F or less, let’s zoom in on the graph around
the right most area of the curve.
a. Point the cursor to a point around the 1000 psia, 0 F coordinate on the graph.
b. Now, push down the left button of the mouse and hold it down while you drag the cursor to the
approximate location of the 400 psia, 30 F coordinate.
c. Release the left button. The program will zoom in on the selected area, and you screen should
look something like this:
From this, we can see the highest dewpoint of this mixture is a little less that 20º F. Therefore, the
cricondentherm dewpoint of this mixture is indeed at or less than our product gas specification.
Our plot is now finished. To print the display, click the Print button.
This finishes our plot exercise. Please return to the main window by closing the current window.
Therefore, please click the close button ( ) on the right hand side of the second bar. This will return you
to the main CHEMCAD window.
Checking the bottoms stream purity…
Our second specification requires that the percent of propane in Stream 9 is to be 1%. We can check
and see if we have achieved this specification by using the Results command. Please point and click on
the Results command or press [ALT + U] now. When you do this, the Results menu will appear.
57
User’s Guide CHEMCAD Version 5.4
We want to check stream compositions, and we want to do it in mole percent. Therefore, we must first
set our flow units. Please point and click on the Set Flow Units option now. The View Flow Rate Units
dialog box will appear. Please scroll down to and point and click on the option, which says Mole %.
Then click [OK]. You will be returned to the Main CHEMCAD Window.
Now click Results again. On the Results Menu, highlight Stream Compositions. On the STREAM
COMPOSITIONS MENU, which appears, click on Select Streams. The Select Streams dialog box will
appear. As before, use the mouse to point to stream 9 and click once. Now click [OK]. The following
display will appear:
We can see from this display that propane is greater than the 1% specification. This means our design
is too conservative. To correct this, let’s go back and re-specify the column to produce precisely 1%
propane in the bottom.
Please click the close button once.
Let’s re-run the stabilizer specifying that we want 1% propane in the bottom. To do this, please double
click on the Tower UnitOp.
The TOWR Distillation Column data entry dialog box for the stabilizer should reappear.
Now, let’s click on the Specifications page of the dialog box. We want to change our specification from
Bottom mole flowrate to a purity specification. Therefore, we must start by changing the mode of the
specification. To do this, please point and click on the field below the Select reboiler mode option and
select Mode 6. This field should now read 6 Bottom component mole fraction. To complete our
specifications, we must identify what that purity is and for which component it is being specified. In the
58
CHEMCAD Version 5.4 User’s Guide
Specification field to the right, we want to enter .01 instead of the present 30. Please do this now. Next,
we must identify the component for which we are making a purity specification. To do this, click on the
component field. A list of all of the components in the component list will open. Click on propane. The
list will close.
Please click on the third page of the screen. Since we have run this condensate stabilizer before, we
want to instruct the program to pick up where it left off at the end of the last simulation. We do this by
making the proper selection in the field labeled Initial flag under Convergence parameters. Please click
on this option. A list will open displaying the available options. The option we want is option number
one, Reload column profile.
We have now made all the changes required to rerun the condensate stabilizer. Let’s save them by
pointing and clicking on the [OK] button.
Please point and click on the Run option on the menu bar. This will cause the Run Menu to reappear.
Please note at this point that since the only unit affected by our changes is the condensate stabilizer
itself, it is not necessary to rerun the entire flowsheet. Therefore, let’s only rerun Unit 5, the condensate
stabilizer. We do this by pointing and clicking on the Run selected Units option. Please do this now.
When we opened the Tower dialog box, we “selected” the Tower UnitOp (UnitOp No. 5). When we
closed that dialog box, UnitOp No. 5 remained selected even though its dialog box was closed.
Therefore, when we told the program to “Run selected units”, it immediately ran UnitOp No. 5 because
it was “selected”. Selected objects are indicated by the four corner boxes which surround them.
When the calculation is finished, the message “Calc Unit 5 TOWR” will appear to the left on the bottom
line of the CHEMCAD window. This should happen almost immediately since the stabilizer runs very
fast.
We now want to insure that we have 1% propane in the bottom stream. We will again do this with the
Results command. Please point and click on the Results command on the menu bar. This will cause
the Results Menu to appear.
Now, highlight the Stream Compositions option and display Stream 9 using the following steps:
1. Point and click on the Select Streams option.
2. Move the cursor to Stream 9, then press the left mouse button.
3. Click [OK].
Stream 9 should now be displayed in a WordPad Window. We can see that propane is now 1%, as
desired.
Now click the WordPad close box to close the stream composition display.
PRODUCING A REPORT
To produce a hardcopy output of any kind, use the Output option on the menu bar. Click Output or
press [ALT + O]. The OUTPUT MENU will appear, and you will have the following options:
59
User’s Guide CHEMCAD Version 5.4
For the purpose of this demonstration, let’s assume we want to print out the following information:
1. For Streams 1, 5, 8 and 9, let’s print the stream composition in mass flowrates and mole fractions,
as well as the default stream properties.
2. The equipment summaries for every piece of equipment in the flowsheet.
3. Tower profiles for the condensate stabilizer.
We will begin with the first item above. We must first specify which streams we want to print out. To do
this, use the Select Streams option on the Report Menu. Please point and click on this option now.
The Select Streams dialog box will appear and will permit you to identify the desired streams either with
the use of the mouse, or by entering the stream ID numbers in the boxes provided. Let’s type in the
desired stream numbers this time. Deselect the check box next to the label Print ALL streams?
1. Deselect the check box next to the field labeled Select from flowsheet?
2. Now we need to identify streams 1, 5, 8, and 9 as the selected streams. First, click on the stream ID
box in the upper left-hand corner under the label Enter the stream ID’s.
3. Type the number 1 into the field.
4. Now, click on another field and type the number 5. It does not matter which box you select. Any
box will do, even if it is not contiguous to the first box. Also note that the TAB key may be used to
move from one field to another.
5. Select boxes for the other streams, and enter the numbers 8 and 9
6. To close the Select Streams dialog box, click on the [OK] button.
60
CHEMCAD Version 5.4 User’s Guide
You will notice that in the default condition the stream compositions will be printed out in units of molar
flowrate. For Tutor1, we do not want mole flowrates; we want mass flowrates and mole fractions.
Therefore, we first need to turn the Mole flow rate off. You can do this by pointing and clicking on the
box to the left of the label. This box currently contains a checkmark indicating that, at this time, mole
flowrates is an active selection. Please point and click this box now.
Now, let’s turn the mass flowrate option on. Please point and click on the Mass flowrate box now.
Finally, let’s turn the Mole Fractions option on by pointing and clicking on that option. Your screen
should look like this:
61
User’s Guide CHEMCAD Version 5.4
Please save these entries by pointing and clicking on [OK] in the bottom-right corner of the dialog box.
This will return you to the Report Menu.
For our final selection, we are going to specify which information is going to be printed for the
condensate stabilizer distillation column. To do this, please select the Distillation Summaries option on
the menu. The Distillation Options dialog box will appear and will permit you to do the following things:
1. Tray profile – Print a tabular summary of the tray profiles for the column, i.e., for each stage the
program will print the temperature, pressure, vapor flowrate, liquid flowrate, and any feeds and
products going to or from the stage.
2. Tray properties – A tabular summary of the transport properties of the vapor and the liquid on each
stage of the column.
3. Tray sizing – Results of tray sizing calculations for each stage of the column. The user may select
from valve, sieve, or bubble cap trays.
4. Packed column sizing – Packed column sizing and pressure drop calculation results.
5. Tray compositions – Tray compositions may be printed in mole or mass flowrates as well as mole
or mass fractions. Only one may be selected.
We are going to print only the tray profiles described in Item 1 above. As you can see from the
checkmark on the dialog box, this is the default option. Therefore, please click [OK] to return to the
Report Menu.
We are now ready to generate our report. Please point and click on the option which says Calculate
and Give Results. When you do this, the report will be displayed in a Word window. It will be formatted
exactly as it would on paper.
All WORD commands are now available for editing, saving and printing.
Once we are finished with the report, close the Word window by clicking the close button. The Report
Menu will reappear. You can now generate more reports if you like. In our case, we want to close the
Report Menu by clicking End Report. You will be returned to the main Simulation window.
62
CHEMCAD Version 5.4 User’s Guide
Another way to obtain a hardcopy output is to create a process flow diagram (PFD). Select the Main
PFD option on the Output Menu.
The program will go into “PFD mode”, which means it will open up certain commands and features that
up to now have been unavailable. These are:
Add Stream Box – The Add Stream Box command is used to create stream data boxes.
Stream data boxes can be used to display the heat and material balance and stream properties.
As many stream data boxes as desired can be placed on a PFD. This command is located on
the Format menu.
Add UnitOp Box - The Add UnitOp Box command is used to create unit operation data
boxes. Unit operation data boxes can be used to display the input and/or output of UnitOps on
the flowsheet. As many UnitOp data boxes as desired can be placed on a PFD. This
command is located on the Format menu.
Add TP Box – The Add TP Box command is used to display the temperature, pressure, and/or
flowrate of a stream in small boxes attached to the relevant stream. This command is located
on the Format Menu.
Refresh Data Boxes – The Refresh Data Boxes command is used to update the stream and
UnitOp data boxes after a new run has been made. It is located on the View menu.
The PFD palette – The PFD palette is a small palette which contains only those graphics
functions which are relevant to creating a PFD. They are the select, rotate, rectangle, ellipse,
line, multiline, text, and Job box functions. These are described below and in the “Drawing
with the Palette” and “How to put text on a drawing” sections of this User’s Guide.
Other commands not consistent with the creation of PFD will “gray out” or become unavailable until we
switch back into simulation mode.
The process of creating PFD’s consist of the following activities:
1. Creating and placing Stream Databoxes on the drawing. Stream databoxes are framed tabulations
of the heat and material balance and stream properties. The content and style of these databoxes
is within the user’s control.
2. Creating and placing Unit Operation Databoxes on the drawing. Unit Operations databoxes are
framed tabulations of selected input and output values for each unit operation on the flowsheet.
Again, the style but not the content of these databoxes is within the user’s control.
3. Adding text to the drawing. Using the text facility on the PFD palette, titles, notes, and various
other text can be placed on the PFD.
4. Placing symbols in the PFD. The user can create and store symbols, such as company logos, in a
symbols library for later retrieval and placement on CHEMCAD drawings.
Drawing primitive (i.e., simple) objects. A variety of 2D objects are available to the user for freehand
object creation.
To see how these work, let’s draw the PFD.
63
User’s Guide CHEMCAD Version 5.4
In order to have adequate space to place additional information on the PFD, the first thing we need to do
is reduce the size of the flowsheet. Please click on the Zoom Out option located on the tool bar.
Zoom Out
Normally this dialog box would be used to list the streams which are to be included in the streams
databox. In our case however we will include all the streams in the databox, so we don’t have to list the
streams. The default is to include all streams. Therefore, click the [OK] button to close the dialog box.
The PFD Property Options dialog box will open.
3. The PFD Property Options dialog box looks like this:
64
CHEMCAD Version 5.4 User’s Guide
This dialog box is used to select which items (for each stream) are to be included in the databox.
Items are selected by clicking the small box next to them. A checkmark indicates that the item will
be included. An empty box indicates that the box will not be included in the databox.
For the purposes of this demonstration, let’s accept the default settings. Therefore, please click the
[OK] button to close this dialog box and save its’ current settings.
4. You will now see the Data Box Settings dialog box. This dialog box looks like this:
Obviously this dialog box is used to make format settings for the databox. For simplicity’s sake let’s
accept the default settings. Therefore, please click the [OK] button now. The stream databox will
appear in the upper left-hand corner of the PFD.
5. Now let’s move the databox so that it fits along the bottom of our PFD. To do this, move the cursor
until it is over the databox. Then, while holding down the left button, move the mouse around until
the databox is in the bottom center of the PFD.
65
User’s Guide CHEMCAD Version 5.4
6. Now let’s resize the databox. Point the cursor to one of the small, black squares at the corners or
the databox. Then, while holding down the left mouse button, roll the mouse around. As you do so
the databox will change size. Move the mouse until the databox is the correct size, and then
release the mouse.
Our stream databox has been successfully completed. You can put as many stream databoxes on a
PFD as you desire. Thus one databox might contain the heat and material balance, while another
contains the stream transport properties. Alternately, one databox might contain stream one through
twenty, while another contains streams thirty through fifty. The system is extremely flexible.
UnitOp databoxes can be created using the same process outlined above. These databoxes can
contain input and/or output information for any selected UnitOp on the flowsheet.
Placing text on the PFD…
Text and other symbols and objects can be put on the PFD also using the PFD palette. The PFD palette
will appear automatically when you enter PFD mode. It’s functions are as shown below:
66
CHEMCAD Version 5.4 User’s Guide
Text can be created and placed on the PFD using the “ab” square. Please click on this square now.
The palette will disappear and the text cursor will appear. Locate the cursor towards the top left of the
PFD in a position appropriate for a title, then press the left mouse button. Now type the PFD title,
“Condensate Stabilizer PFD”. When finished double click on some vacant spot. The palette will
reappear.
We now have a complete process flow diagram. We can generate a hardcopy of this PFD by clicking
the Print button.
To close CHEMCAD, click on the Close in the upper right hand corner of the window. When you do this
CHEMCAD will ask you if you want to save the changes to the PFD. Please answer “yes”. The top-level
window of CHEMCAD will open. Close this window to exit to the operating system.
We are now finished with our demonstration.
SUMMARY
67
User’s Guide CHEMCAD Version 5.4
CHEMCAD-BATCH TUTORIAL
INTRODUCTION
This tutorial provides basic input skills for operation of CC-BATCH. The CHEMCAD input convention
and rules apply to CC-BATCH as it does to all other modules. Since CC-BATCH is a module of
CHEMCAD, the names will be used interchangeably in this tutorial. The input procedure for CHEMCAD
is simple and straightforward, designed to be intuitive for a chemical engineer familiar with the Windows
environment. However, for the sake of clarity and for those new to this environment, a review of some of
the basic rules for using CHEMCAD is given. These rules are demonstrated as we apply them to solving
this batch distillation problem.
The following ten basic steps are used to run a flowsheet simulation in CC-BATCH
• Start a new job
• Select engineering units
• Create a flowsheet
• Select components
• Select thermodynamics options
• Input initial change and/or feed stream data
• Specify the batch column (configuration and operations)
• Run the simulation
• Review the results
• Generate hardcopy output
The steps do not have to be performed in this order nor do all of them have to be done for every CC-
BATCH flowsheet since defaults exist for some of them. All should be considered for each problem.
There are a series of Help facilities available throughout the program. The bottom line of the screen
provides a one-sentence description of the current highlighted item. The Help command provides
access to the On-line Manual, which contains comprehensive technical information. The [F1] key
provides context sensitive help (place the cursor in a specific field and press the [F1] key). The Coach
facility will provide instructions on how to perform selected tasks. Use of these help facilities will ease
your way through the program.
CHEMCAD is object oriented. Therefore, most input and editing can be done by double clicking or right
clicking the object of the operation, as well as by using the menu commands.
68
CHEMCAD Version 5.4 User’s Guide
All stream and unit operations specifications (input) are accomplished using dialog boxes. These dialog
boxes are context specific and employ some combination of character fields, combo boxes, choice
boxes and check boxes.
The mouse is a very easy to use way to get the computer to do what you want. CHEMCAD, like many
windows programs, requires the use of a mouse, trackball, or similar pointing device with both a primary
and secondary button (i.e. a standard Microsoft 2-button mouse). The basic Mouse techniques are
summarized below:
Click To quickly press and release the primary mouse button. For
most right-handed mice, this is the left button.
Right-click To quickly press the secondary mouse button. For most
right-handed mice, this is the right button.
Double-click To press the primary button twice in rapid succession.
Drag To press and hold down the mouse button while moving the
mouse.
Point To move the mouse arrow until it points at the item of
choice.
Right-click hold A technique used mainly in Windows 95 and NT. Point the
mouse to a specific area, then click and hold the secondary
mouse button.
• The [TAB] key is used to move to the next field on a data entry dialog box.
• The [PgUp] and [PgDn] keys may be used to “page” or scroll through lists.
• Holding down the [SHIFT + TAB] will cause the program to move back or up one field.
69
User’s Guide CHEMCAD Version 5.4
The “Standard” way of executing commands in CHEMCAD is to click a command on the Menu Bar and
follow that command down through the subsequent menus until the desired function is reached. Thus, to
select components from the databank, one would first click the command ThermoPhysical on the
Simulation Menu Bar; click the option Component List from the ThermoPhysical Menu and finally
select components from the Component Selection dialog box.
There is a shorter way of reaching this and other frequently used functions. This is to use the
CHEMCAD Power buttons, which are located on the tool bar. This tool bar is toggled on and off using
the View/Toolbar command.
This tutorial walks the user through the input and simulation of a simple five-step batch distillation
problem. This problem is illustrated below in Figure 1 and all input data are given in Table 1.
Figure 1
70
CHEMCAD Version 5.4 User’s Guide
GETTING STARTED
The first time you run CHEMCAD the Top Level Window will appear on your screen. Please maximize
this window (that is, zoom it to fill in the screen) by clicking the Maximize button in the upper right hand
corner of the CHEMCAD window. This will cause CHEMCAD to fill your screen and your display should
look something like this:
71
User’s Guide CHEMCAD Version 5.4
Close Button
Tile Button
Minimize Button
The top line is called the Title Bar. It contains the CHEMCAD logo and name on the left side, and the
WINDOWS minimize, tile, and close buttons on the right side.
The next line is called the Menu Bar. This bar contains the top-level commands for CHEMCAD. They
are:
File This command is used to define output formats, open jobs,
print, and obtain general information about CHEMCAD.
License This command is used to configure license, update dongles
and authorize special licenses.
View This command enables the user to toggle the Tool bar and
Status bar on and off.
Help This function allows the user to call the on-line Help facility.
The third line (or bar) is called the Tool Bar. It contains the symbols to directly invoke short cuts to
various file functions that would otherwise be accessed through the menus.
The remainder of the window is inactive at this level.
The current window displays only the top-level of CHEMCAD. CHEMCAD also has other levels for
drawing the flowsheet, setting up and running a simulation, and generating PFD’s and reports. In the
course of this tutorial, you will be introduced to the most important of these levels and their use.
72
CHEMCAD Version 5.4 User’s Guide
Let’s start by opening a new job and giving it a job name. The File command is used for this. To open
the File menu, click on the word File on the menu bar.
Now choose the New Job option by clicking on it.
The following dialog box will open:
This dialog box is prompting you to enter a name and folder for the new job. Let’s use the name
BATCHDIS. Please enter this name in the field labeled File Name. Then close the dialog box by
clicking the [Save] button. You will be taken into the main working window of CHEMCAD.
Palette
Active Area
The major features of this window are labeled above as described below:
The top line, called the Title Bar, now contains the CHEMCAD logo and the current job name, as well
as, the minimize, title, and close buttons which are always present on the left side.
73
User’s Guide CHEMCAD Version 5.4
The Menu Bar follows the Title Bar and consists of fifteen commands in addition to the Help command.
These commands are:
The Menu Bar is followed by the Tool Bar. The toolbar contains “power buttons” or short cuts to
specific frequently used functions. These toolbar functions are explained in an earlier section of this
guide.
Below the Tool Bar is the Active Area. Notice that this area is accompanied by elevator bars for
scrolling the active area display up and down, and left and right. Because we have not yet drawn our
flowsheet, the Active Area is now blank except for the Main Palette.
74
CHEMCAD Version 5.4 User’s Guide
The Main Palette provides access to the graphics functions, which are necessary for the creation of the
flowsheet.
To select engineering units for this flowsheet, select the Format command either by pressing [ALT + M]
or by clicking it with the mouse. The following menu will appear:
Now select the Eng Units option by clicking on it with the mouse. The following dialog box will appear:
75
User’s Guide CHEMCAD Version 5.4
The ENGLISH units option is the default and is currently highlighted. You may change the engineering
units system by clicking any one of the four buttons English, Alt SI, SI, or Metric, or you can change any
unit individually by clicking on the individual item and then selecting from the list presented. For this
tutorial we will use English engineering units, therefore just exit the dialog box by clicking the Cancel
button.
To draw the flowsheet you will be working with the flowsheet palette which looks like this:
• The second box enables the user to rotate objects on the flowsheet.
• The next five boxes (reading horizontally) enable the user to draw the indicated primitive on the
flowsheet.
• Box number eight, the “ab” box, is used to put text on the drawing.
• Box number nine is for drawing process streams (streams must connect unit operations).
• The remaining boxes each represent one of the unit operations in the CHEMCAD library.
• Pointing to a box with the cursor will cause a small descriptive label to appear which will indicate
what each box represents.
• Pointing to a box and clicking with the left button of the mouse will activate the corresponding
function.
76
CHEMCAD Version 5.4 User’s Guide
• Pointing to a box and clicking with the right button of the mouse will cause a sub-palette of icon
options to be displayed. Right clicking again (on the same master palette box) will cause the
sub-palette to disappear.
• Multiple sub-palettes may be displayed simultaneously.
• The main palette may be switched on and off using the View\Main Palette command, by
clicking on the Run Simulation command, or by clicking the S/G Power button.
• The size and shape of the main palette can be controlled using the View\Palette Settings
commands.
• On the icon display, inlets are indicated by small blue circles and outlets by small red circles.
Our purpose now is to set up the flowsheet topology. Creating a flowsheet is the process of placing unit
operations icons on the screen, connecting them with streams, and then adding various graphical
objects to enhance the drawing. All of these things may be done using the palette.
Let’s begin our flowsheet by placing the Batch Column Unit on the screen. Please follow the procedure
given below:
1. The first task is to locate the Batch Column UnitOp icon on the Palette. The icons are arranged
alphabetically and whenever you point to an icon tile with the cursor, a label appears describing the
tile. Therefore, move you cursor around the palette until you locate the Batch Column tile.
2. Click on this tile to select the Batch Column icon. The palette will close and the UnitOps placement
cursor (a small square) will appear on your screen.
Note that the one-line help on the bottom information bar is now giving you instructions as to how to
proceed. It should currently say; “Select location for: Batch Column”
3. Move the cursor to the middle left of the screen and click again. The Batch Column icon will appear:
77
User’s Guide CHEMCAD Version 5.4
Note: A UnitOp ID (the number ”1” in the circle) has automatically been assigned to this icon.
This can be changed if desired.
This completes the placement of the UnitOp Batch Column. Notice that the palette has reappeared and
is available for placing additional unitops on the flowsheet.
For purposes of instruction, let’s explore some of the options associated with this icon:
a. To move the symbol:
• Place the mouse arrow on the icon.
• Hold down the left button on the mouse. The four windows object boxes will appear.
• With the left mouse button held down, drag the icon up about one-inch, then release the
left button of the mouse. The icon position has been changed.
b. It may be necessary to move the palette out of the way in order to have access to the icon. You
can do this by clicking and dragging on the red bar at the top of the palette.
c. To view the object editing options: place the mouse arrow on the icon (on the flowsheet, not on
the palette) and press the right button on the mouse.
d. To move or stretch an object: left click on the icon so that the four object boxes are displayed
around the icon. Then click and drag on one of these boxes. The icon will grow or shrink
according to the mouse movements.
Now let’s place the time switch on the flowsheet. Please follow the procedure given below:
78
CHEMCAD Version 5.4 User’s Guide
• Click the Time switch icon. The palette will disappear and the UnitOps cursor will
reappear.
• Move the UnitOps cursor to about one inch directly to the right of the Batch Column top
outlet.
• Place the time switch here by pressing the left mouse button. Your screen should look
something like this:
79
User’s Guide CHEMCAD Version 5.4
We still have to place the Tank units on the flowsheet. Since we have three product streams
(see Figure 1), we must have three Tank UnitOps. Use the above procedure to place them on
your flowsheet something like this:
It’s now time to connect the UnitOps with streams. To do this, click the Streams icon box on the main
palette.
There are a few general rules to remember when we are drawing streams on the flowsheet:
1. Each stream goes from a source unit to a destination unit.
80
CHEMCAD Version 5.4 User’s Guide
2. Each unit has inlet and outlet positions. These are established when the symbol is created. The
program always snaps streams to these positions. During the simulation, a process stream always
flows from an outlet position on a source unit to an inlet position on a destination unit, but when
drawing the flowsheet a stream may be drawn in any direction; that is; from an inlet position to an
outlet position as well as from an outlet position to an inlet position.
3. When starting a stream, the cursor will be a small cross. When the cursor gets near an outlet
position, it will convert to a black arrow. When this occurs you should left click the mouse to start
the stream if that is the starting position you desire.
4. When completing the stream to a unit, the cursor will remain as a black arrow. When the cursor is
near an inlet or outlet position, a label will appear indicating the location and number of the position.
5. Once the desired position has been located (as indicated by the appearance of the label), you
should left click the mouse to complete the stream.
6. While drawing a stream, the palette will disappear. It will reappear only when you left click
somewhere on the flowsheet which is not a UnitOp inlet or outlet point. You are not required to click
the stream (link) icon tile each time you begin a stream.
7. You can alternate between placing UnitOps on the screen and connecting them with streams as
long as the above rules are followed.
8. The first time you change directions of a stream, CHEMCAD will let you do so without any problem.
Every additional time you change directions, you must first press the left button on the mouse to
identify the longitude or latitude through which you want the stream to pass. Doing this will create
an anchor point to fix the longitude or latitude on the screen.
9. You may cancel the stream drawing action by double clicking the left button during the stream
drawing process.
With these rules in mind let’s place the streams on our flowsheet. First, click on the streams square:
Move the cursor close to the top most outlet arrow of the batch distillation icon. When the correct outlet
position is identified, press the left button on the mouse. Draw the stream over to the right with your
mouse. When the left-most inlet on the time switch is identified by its label, press the left button on the
mouse. CC-BATCH will draw the stream directly to that point and will place a stream ID number on the
flowsheet. CC-BATCH issues ID numbers sequentially, so this ID will be Number 1. You may change it
using the EDIT STREAM menu (invoked by right clicking the stream) if you would like to do so.
Let’s draw the second stream. Move the cursor around until the right-most outlet position on the time
switch is located and press the left button on the mouse. Draw the stream over to the first Tank when an
outlet position is identified; press the left button on the mouse again. This should complete Stream 2.
Next, let’s draw the stream from the time switch to the second Tank. Move your mouse close to the
outlet on rightmost available outlet on the time switch until the black cursor arrow appears. Press the left
button on the mouse. Next, draw the stream over to the second tank until the first inlet position label
appears. Press the left button on the mouse to complete Stream 3.
81
User’s Guide CHEMCAD Version 5.4
Let’s draw Stream 4. Move the cursor near the time switch until the next outlet position is identified and
press the left button on the mouse. Now, draw the stream over to the last Tank. When that inlet position
label appears, press the left button on the mouse again to complete Stream 4.
Your screen should now look something like this:
We are now finished drawing our flowsheet. To move on we need to close the Edit Flowsheet mode by
clicking the Run Simulation command on the menu bar or by clicking the S/G button on the tool bar.
SELECTING COMPONENTS
Next let’s identify which components are to be used in this simulation. Selecting the Component List
command in the ThermoPhysical Menu does this. This may be done by pressing [ALT + L] or by
clicking with the mouse. Do this now please. The following menu will open up:
82
CHEMCAD Version 5.4 User’s Guide
To choose components from the standard CHEMCAD databank, click the Component List option with
the mouse. The following Component Selection dialog box will appear. This dialog box is organized
as indicated below:
Insert button
Add button
Clear button
Delete button
Next button
83
User’s Guide CHEMCAD Version 5.4
matching the string entered in this field. The string can be any alphanumeric combination. The
string will be matched to any part of an ID numbers, formula, or synonym (component name) listed
in the databank.
As you type in the string, the program automatically finds and highlights the closest match. As the
string changes, the highlighted component changes.
Next button: If the current match is not the component you are looking for, click the Next button to find
the next matching string.
Copy Components from another job: The Copy Components button is used to import the component
list from another CHEMCAD job. When this button is clicked, the user is prompted to browse for the
location of the CHEMCAD job from which the components will be imported. These components are
the added to the Selected Components Area.
To show how a component is selected, let’s select propane. First, click on the Selection String Field,
and then type in the string “propane”. As you build the string, the program will locate and highlight the
component propane. To add it to the component list, click on the Add button or double click on
“propane” in the Component Databank Area. The selected component will appear in the Selected
Components Area.
Propane could just as easily been located by entering the string “C3H8” in the field. The same thing
could have been done with the number “4” which is the ID number for propane. Strings, which comprise
only part of the word, number, or formula, can also be used. It is also possible to highlight the desired
component by clicking on it directly.
Now select the remaining components in the component list. If the first search does not locate the
desired component, click the Next button to find the next matching string. Find the following
components and add them to the component list:
4 Propane
6 N-butane
8 I-pentane
10 N-hexane
Your dialog box should now look like this:
84
CHEMCAD Version 5.4 User’s Guide
Let’s now save our list by clicking the [OK] button. The ThermoWizard will appear.
After the user first selects components the ThermoWizard will appear. The ThermoWizard is a system
available in the CHEMCAD Suite to assist the user in making K-value and enthalpy choices.
85
User’s Guide CHEMCAD Version 5.4
CHEMCAD has a library of about 50 K-value models with a variety of options, and about twelve enthalpy
models. Making the proper selection from these libraries can sometimes be difficult. The issues
involved and the proper techniques for selection are described in the Thermodynamics section of the on-
line manual.
Because the issues involved in making thermodynamic selections and in using the ThermoWizard are
beyond the scope of this tutorial, let’s assume we know that we want to use the Peng-Robinson method
for both the K-value and enthalpy calculations. In this case, we would proceed as given below.
First, we need to accept the default temperature/pressure values for the ThermoWizard,. The Wizard
will recommend using SRK, please accept this message box. Then let us now make our own selection in
the K-value Options dialog box. In the upper-left corner of this screen will be a combo box labeled
Global K-value Option, which is currently highlighted. Please open this window by clicking on it.
You will notice the presence of a Scroll Bar at the right of this list indicating that all of the available
options could not fit into this area. Therefore, the user may scroll through them using any of the methods
previously described in this tutorial. We would like to use the Peng-Robinson method. To make this
choice, please scroll up through list; point the arrow to the Peng-Robinson option; and click the left
button on the mouse. The box will close and Peng-Robinson will now be displayed in the field. Your
screen should now look like this:
The other options on this screen are not important to us at this time. Therefore, let’s save our selection
by pointing and clicking the [OK] button in the lower right corner. This will return you to the Simulation
Menu Bar.
Now, let’s select our enthalpy model. Do this by again clicking the ThermoPhysical command, then
clicking the Enthalpy option. The Enthalpy Options dialog box will be displayed. You will notice on
this screen that the Peng-Robinson method has already been chosen. The program automatically
makes this the enthalpy model when you choose the Peng-Robinson K-value method. If this assumption
is erroneous, you may override it at this time. In our case, we would like to use the Peng-Robinson
model, so let’s point and click on the [OK] button in the lower right portion of the screen. This will close
the Enthalpy Options dialog box, saving the currently displayed options.
For the purpose of our tutorial, the thermodynamic selections are now complete.
86
CHEMCAD Version 5.4 User’s Guide
Feed streams are input on a batch flowsheet only when the column is operating in semi-batch mode or
the batch column is to be used with steady state units in a combined flowsheet. Neither of these
conditions exists in this tutorial. The initial charge for the column is input in the equipment data entry
screen described below.
Equipment parameters may be input using either the Specifications command on the menu bar or by
clicking directly on the UnitOp we wish to specify. The latter is easier. Therefore, please point and
double-click on the batch distillation column now. The first time through, CC-BATCH will sequentially
display the necessary input dialog boxes for complete specification of the batch column configuration
and operations.
The kinds of data input to the system by a user are divided into four groups. These groups are explained
below.
POT CHARGE DEFINITION
This data defines the thermodynamic conditions, amount, and composition of the pot charge. It is
treated similarly to a stream except that there is no rate data. Masses and enthalpy are treated as static
amounts.
BATCH COLUMN SPECIFICATIONS
This data defines the column but not its operation. It includes number of stages, holdups, pressures,
feed tray locations for reservoir, side product draw locations, heater/cooler locations, and the overall U,
area, and ambient temperature for the heat loss calculation. Also provided here are any initial estimates
the user may wish to provide.
OPERATION PARAMETERS SPECIFICATION
This data defines the operation of the column during an operation step. It includes specifications such
as reflux ratio, distillate rate, total reflux boilup rate, etc., as well as the stopping criterion. It also
includes startup options and receiver tank assignments.
SET SCREEN INFORMATION SPECIFICATIONS
This data defines the variables displayed dynamically as the batch run proceeds.
When entering UnitOp data for a batch column for the first time, CC-BATCH will walk you through the
data entry by successively displaying dialog boxes for each of the above types of input. It will then save
this input. When the user wants to return to these dialog boxes for review or editing, the Batch Column
Input menu will be displayed. This menu is a gateway to the data entry dialog boxes.
87
User’s Guide CHEMCAD Version 5.4
This dialog box allows the user to delete operation steps. If the user wants to delete a new step n and
then he/she should input ‘n’ in this field. The old step n+1 will be now identified as step n.
COPY OPERATION STEP SPECIFICATIONS
This dialog box allows the user to copy all specifications from a step to another. If the user wants to copy
parameters of a step to another step, he/she should input the numbers of the step source and the
recipient step. The previous recipient parameters (if any) will be erased and replaced by those of the
source step.
We are now ready to define the Pot Charge. The Pot Charge dialog box is the first screen to appear
when you select the batch column for equipment specification. Therefore, the following input dialog box
should now be displayed:
88
CHEMCAD Version 5.4 User’s Guide
Now we will define the amount and composition of the initial pot charge. The user may define the
amount of each component present or the fractional composition of each component present and the
total charge. In our case, we want to do the latter. Specifically we want to set the total initial charge
equal to 100 lb.-moles and want to define the mole fraction of each component.
The Pot Charge is 100 lb.-moles of the following composition:
0.1 mole fraction propane
0.3 mole fraction n-butane
0.1 mole fraction n-pentane
0.5 mole fraction n-hexane
You will notice that the Total Flowrate field is grayed out. This is because the Component Flow Units
are lb.-moles. In any situation where the component flow units are not fractions (mole, mass, or
volume), the total flowrate will always be equal to the sum of the component flowrate. CHEMCAD sums
the entries as they are entered. Entering a value for total flowrate would be superfluous and therefore
the field is grayed out.
To enter the composition in the desired units, we must first change the component flow units to mole
fractions. Please click the Component Flow Units field now. The highlight will move to this field and a
small triangle in a box will appear to the right of it. Now click on this small triangle. A list will open
displaying all the available options. Scroll down this list to mole fractions (To scroll you may use the
elevator bar, the arrow keys, or the [PgUp] and [PgDn] keys). When the option mole frac is displayed,
click it once.
The Total Flowrate field and the Total Flowrate Units field should now be open. Therefore, please do
the following:
1. Click the Total Flowrate field and enter 100.
2. Tab down to the propane field and enter 0.1. Then press the [Tab] key.
3. Your cursor should now be on the n-butane field, so enter 0.3, [Tab].
4. Enter 0.1 in the n-pentane field.
5. Enter 0.5 in the n-Hexane field.
89
User’s Guide CHEMCAD Version 5.4
In order to exit this menu and save the data, you should click the [OK] button in the upper right-hand
corner of the dialog box. This will save the data and automatically display the Batch Distillation
Column dialog box.
After specifying the charge composition and conditions, the program will prompt you to establish the
column configuration. This is done by displaying the Batch Distillation Column dialog box.
In this example problem, we have 8 stages, five operating steps, internal stage holdup is 0.01 cubic feet,
the condenser holdup is 1 cubic foot, pressure at the top of the column is 14.7 psia, and the pressure
drop across the column is 2. It is okay to assume that the condenser has essentially no pressure drop.
The column configuration menu should be completed like so:
90
CHEMCAD Version 5.4 User’s Guide
You will notice page tabs, labeled General and Misc. in the upper part of the dialog box. We are
currently on the General tab. The Misc. tab provides additional options. These options are not used for
this simple example so we will not look into them now.
Once the input has been entered, click the [OK] button with the mouse. This will save the data and
automatically display the first Batch Operating Parameters dialog box, which is used to define the
operating steps of the column.
For this simulation there are to be five operating steps, sequentially one after the other. It is now time to
define what the operating parameters are for each step.
OPERATING STEP 1
The Batch Operating Parameters dialog box data input screen must be completed for each of the five
operating steps. Let’s go through the input fields item by item to learn how they are to be completed.
1. Start-Up Option – Please click on this field to list available options.
The first step starts from total reflux. Therefore, please click the Total Reflux option. The list will
then close.
2. Product Assignment – The product assignment fields identify which accumulator a product or
decant stream is to be sent to. It is not necessary to actually place accumulation tanks on the
flowsheet to use this option (although we did); simply designating a unit ID number will be sufficient.
Obviously, you must be careful not to designate a unit ID number that is being used by some other
unit in the flowsheet (which is not a tank). These ID numbers may be chosen arbitrarily and
91
User’s Guide CHEMCAD Version 5.4
switched as often as desired. In this way, the user may keep track of output from individual
operating steps or combinations of operating steps if desired.
Since CC-BATCH permits vapor-liquid-liquid distillation, there may be two liquid phases in the
condenser, possibly giving rise to decanting of one phase or the other. The need for multiple
overhead accumulators thus arises and is permitted in the program.
Distillate Tank # - The overhead tank accumulates the distillate.
Decanter Tank #– The decanter tank accumulates the decanted liquid (if any).
In this particular example, no decanting takes place, so only the Distillate Tank # field is filled in.
Enter a [3] (indicating the Tank with Unit ID 3) here and strike the [Tab] key #. Now move to the
First Spec Mode field.
3. First Spec Mode – When a batch column is refluxed, you must make two operating specifications
for each operating step. Click the field with the mouse to open the combo box:
As Table 1 explains, the first specification for operating step number 1 is to set the reflux ratio equal
to 5. Therefore, select Reflux ratio for this mode. You may do this by clicking on it with the mouse
or by using the arrow keys to highlight this selection and then pressing the [ENTER] key. Since
Reflux ratio is the default for the first mode, the highlight will already be on this selection.
4. First Spec Value – Now move to the First Spec Value field by clicking on it with the mouse (if you
are using the [Tab] key you will already be there). In the First Spec Value field we will enter the
numerical value of the reflux ratio, i.e., 5. Therefore, please enter [5] in this field and then press the
[Tab] key.
Component – Component not shown on screen unless it is needed.
92
CHEMCAD Version 5.4 User’s Guide
5. Second Spec Mode – Now click the Second Spec Mode field display the list of the available
options. The mode we want to select (Distillate Mole Flowrate), is the first (default) mode.
Therefore, strike the [Tab] key to make this selection and move to the next field.
6. Second Spec Value – Just as in mode 1 above, we will now define the numerical value for the
second specification. This is 2 lb.-moles/hour, therefore, enter [2] in this field.
7. For Subcooled Condenser Only – If a subcooled condenser is present, the actual subcooled
temperature or the degrees of subcooling may be specified. There is no subcooling in this example
so these fields may be ignored.
8. Integration Time Step Size in Hours –
Step Size (HR) – This field provides the integration time step size in hours. The default value is
0.05 hours. The user may override this value if he/she so desires. In this case, we will not do so.
Therefore, please move on to the next field.
9. Record Frequency – CC-BATCH generates a lot of output data. It is generally not necessary to
record all of the information calculated at each time step on the hard disk. Therefore, in the default
condition, CC-BATCH only records the information at every third step. If the user should wish to
record the information more or less frequently than that, he/she may do so by entering the desired
frequency in this field. In our case, we will leave the default value of 3. Therefore, please move to
the next field.
10. Operation Stop Option – The user may select from a variety of criteria to establish when an
operating step is to be stopped. Three fields, Stop When, Stop Value and Measured Value, define
the criteria for stopping this operation. To see how this works, click on the Stop When field and
open the window (click on the field with the mouse).
93
User’s Guide CHEMCAD Version 5.4
Stop When – As you can see from the screen, the Stop When field allows the user to define
whether the operating step is to be stopped based upon time or whether it is to be stopped based on
some condition existing in either the accumulator, the distillate, or the residual charge in the bottom
of the column. We want to stop step 1 when the mole fraction of butane in the distillate reaches
20%. Therefore, our Stop When criteria is the distillate. Therefore, please select Distillate.
Stop Value – This is the numerical value of our stop criteria, 20% in our case. Therefore, enter a
[0.2] in this field and move to the Measured Value field.
Measured Value – This field allows us to identify what value of the distillate 0.2 represents. Please
click on the choice box and view the options.
In this example, 0.2 represents the mole fraction of n-butane. Therefore, select mole fraction here.
When you do this three additional fields will open: the Use multiple components field, the First
component field, and the Last component field. Cued by our identification of the Measured Value
as a mole fraction spec, the program opened these fields knowing them to be what we need to
complete our specification. Different Measured Value selections will produce different fields.
Use multiple components – Purity specifications can be made for a single component or for a
range of components. A checkmark in the Use multiple components field indicates that the
specification is for a range of components. In this event the first and the last component in the
range must be identified. Obviously then the components in a multiple components specification
must be contiguous within the component list for the flowsheet. This is the default condition.
The specification we want to make however is for a single component. Therefore, we need to click
the Use multiple components box to remove the checkmark. When we do this, the Last
component field will disappear and the First component label will change to Component.
Component - We will use this field to identify n-butane as the component which to have a mole
fraction of 0.2 in the distillate. The operating step is to stop when this condition is met.
11. Stop Tolerance – This field defines how close to the specification made above we must be before
stopping. The default stop tolerance is 0.001. That is generally an adequate value and we will
leave it alone for this case. Therefore, please move on to the next field.
12. Minimum Run Time – Some specification values will go through maximums during the simulation.
This situation can cause the program to stop earlier than intended. To prevent this, the user is
asked to specify a minimum runtime. Let’s use half an hour here, so please enter [0.5] in this field.
The remaining fields on this data entry screen are not necessary for the input of this operating step and
therefore will not be explained here.
94
CHEMCAD Version 5.4 User’s Guide
Now click the [OK] button with the mouse to move on to Operating Step 2.
OPERATING STEP 2
In Operating Step 2, we want to change the reflux ratio to 20, keep the distillate rate at 2 lb.-moles per
hour, and stop the operation when the mole fraction of butane in the distillate is equal to 0.985.
Therefore, you should complete the menu for Operation Number 2 as follows:
95
User’s Guide CHEMCAD Version 5.4
In Operating Step 3, we are going to switch the distillate to UnitOp 4 (the second tank), increase the
reflux ratio to 25, keep the distillate flow rate 2 lb.-moles per hour, and stop the operation when the mole
fraction of butane in the accumulator is equal to 0.99. The General tab of this dialog box is therefore
completed as shown below:
In addition, at the beginning of the operating step, we want to add 20 moles to the pot of a mixture which
is 40% butane and 60% hexane. To do this we need to use the Add material to pot option on the
Additional Settings tab of the dialog box. Please click on this tab now and click on the Add material
to pot field. A check mark should appear in this field as follows:
96
CHEMCAD Version 5.4 User’s Guide
Add
material
to pot
This time when you click the [OK] button to exit the Batch Operation Parameters dialog box, a Edit
Batch Change/Add dialog box will appear. This dialog box is to permit the user to define the
thermodynamic conditions and composition of the material being added to the pot. In our case, let’s set
the temperature equal to the bubble point at 16.7 psia. Therefore, please enter a 16.7 in the pressure
field, 0.0 for vapor fraction, and leave the temperature and enthalpy fields blank. We must also set the
composition and amount added to 0.6 mole fraction n-butane, 0.4 mole fraction n-hexane, and 20
lbmoles total. To do this click on the Comp Unit field and open the units options list. Select mole
fractions. Enter 0.6 for n-butane and 0.4 for n-hexane. Then enter 20 in the Total flow field.
97
User’s Guide CHEMCAD Version 5.4
Then click the [OK] button to save the data and move on.
OPERATING STEP 4
In Operating Step 4, we are going to switch the distillate to UnitOp 5 (the third tank) reduce the reflux
ratio to 15, maintain the distillate rate at 2 lb moles per hour, and stop the operation when the mole
fraction of hexane in the distillate equals 0.2. We will also enter 0.5 for the minimum runtime to make
sure the step runs at least 30 minutes. Therefore, your menu should be completed as follows:
In Operating Step 5, we are going to increase the reflux ratio to 25, maintain the distillate rate at 2 lb.-
moles per hour, and stop the operation when the mole fraction of hexane in the residual charge in the
bottom of the column is equal to 0.9998. We will also enter 0.5 for the minimum runtime to make sure
the step runs at least 30 minutes. There are no other special operating features in this step. Therefore,
you should complete the operation 5 dialog box as follows:
98
CHEMCAD Version 5.4 User’s Guide
Now, click [OK] to enter the data. CC-BATCH will now display the RunTime Information menu.
RUNTIME INFORMATION
The Runtime Information menu allows the user to choose which variables are plotted on the screen
during calculation. A wide variety of options are available as the screen shows. For this example, let’s
display the distillate mole fractions of all four components during runtime. This is the default output for
the batch distillation column.
Your screen should now look like this:
99
User’s Guide CHEMCAD Version 5.4
After completing this dialog box, click the [OK] button. The Runtime Information dialog box will close
and the Batch Distillation menu will appear. This menu allows the user to return to any of the above
screens by clicking the appropriate choice.
All the input data has been entered now and we are ready to run the simulation. But first we must exit
the current menu. Please click the Exit button on the Batch Distillation menu.
To run the simulation, point and click on the RUN command on the top-level menu or press the [ALT +
R] keys. This will cause the RUN menu to open up like this:
100
CHEMCAD Version 5.4 User’s Guide
Even though batch distillation is a dynamic process, CC-BATCH is run from the Run All command.
When this command is executed, CC-BATCH will first check the input data for errors or omissions. If
any are found, messages will be sent to the screen indicating the error(s). Two types of messages may
be issued:
• Error Messages – These are errors or omissions, which must be fixed before the simulation can
proceed. Under specification of the batch column would be an example of this type of error.
• Warning Messages – These are usually input omissions, which may or may not cause problems
upon execution. These are non-fatal and therefore do not need to be dealt with or corrected prior to
simulation. They are for the users information and based upon these messages the user may
choose to make changes or not.
In this example, if all input has been done correctly, there should be no messages of any kind and the
program will proceed directly to the calculation. Please click on the Run All command now.
You will notice during the simulation that the mole fractions in the distillate are plotted on the screen in a
plot window. This is because we requested this in the Runtime Information dialog box during the
batch column input. In addition, you will notice that each time the program proceeds to a succeeding
operating step a new plot window will open. This new plot window will be maximized (will fill the screen)
and you will be able to see only those results from the current operating step. You can change this by
tiling or cascading the open windows using the Window\Cascade or the Window\Tile commands.
When the simulation is finished, the dynamic plot will quit scrolling.
If you have not done so already, click the Window command on the menu bar and then click the Tile
command on the menu that opens up. The open windows will tile and your screen should look
something like this:
101
User’s Guide CHEMCAD Version 5.4
To proceed, let’s close all the plot windows and take a look at the review features of the program.
Once the simulation is complete, we will want to review the results interactively before printing a
hardcopy. We do this using the Results and Plot commands on the menu bar.
For batch calculations the most convenient way to examine the output is to plot the results. To do this,
you would use the Plot command. Therefore, click the Plot command on the menu bar. The Plot Menu
will open.
102
CHEMCAD Version 5.4 User’s Guide
We want to plot the results of a batch distillation simulation, so we want to plot a Batch Column History.
Therefore, please select this option now. The Select UnitOp(s) dialog box will appear. Click the batch
column icon. The UnitOp ID number (1) will appear in the dialog box field. Now click [OK]. The Select
UnitOp dialog box will close and the Batch Column Options dialog box will appear like so:
This dialog box is similar to the Runtime Information dialog box that was used before running the
simulation. To plot the distillate mole fractions we need to do the following:
• Select mole fractions
• Select the distillate
• Select components (enter their position numbers)
Leave the Operating Step field blank so that all operating steps will be plotted in the same window.
Now click the [OK] button and the following plot will appear:
103
User’s Guide CHEMCAD Version 5.4
You are now in a plot window and your available commands have changed. These commands are the
same for every plot (except for the title). This window is similar to other graphics windows in CHEMCAD,
and the following commands are available:
File For printing and print management, job management, window opening and
closing
Edit The Undo, Cut, Copy and Paste commands
View To turn the tool bar and the status bar on and off
Graph For performing various plot editing and data transfer functions
Window For windows management (tiling, cascading, etc.)
Help For help with the plot edit functions
At this point, let’s make note of a few important items regarding CHEMCAD plots.
1. To zoom in on a certain section of the plot, point to one corner of the area that you want to zoom in
on, and then click-and-drag (i.e., hold down the left mouse button while you are moving the cursor)
to the opposite corner of that area. When you release the mouse button, the program will zoom in
on the boxed in area. To restore the original size, click on the Graph command (on the menu bar);
then click on the Zoom Out command.
2. The plot title text (in this case, Batch Column 1, Distillate) can be edited using the Graph\Edit titles
command.
3. The color, size, layout and various other aspects of the plot presentation can be edited using the
Chart Explorer function.
4. A hardcopy of this plot can be obtained by clicking the Print button.
This finishes our plot exercise. Please return to the Simulation window by closing the current window.
104
CHEMCAD Version 5.4 User’s Guide
Certain batch results can also be viewed in tabular format. To do this, please point and click on the
Results command or press [ALT + U] now. When you do this, the Results menu will appear. Please
point and click on the Batch Results option now. A summary of the results of this simulation will be
displayed in tabular format inside a Wordpad window like so:
This display provides a summary of the batch simulation at the end of each operating step. You may
browse, edit, or output this display using any of the Wordpad commands. The WordPad commands can
be used to edit and/or print the results. After browsing, return to the main CHEMCAD window by closing
the Wordpad window.
105
User’s Guide CHEMCAD Version 5.4
Complete this screen as desired then click the [OK] button. You will be returned to the Reports Menu.
Then select Calculate and Give Results. The report will be generated and displayed in a Word
window. You are now in a position to browse, edit, and print the report as desired using any of the
available Word commands.
We are now finished with our tutorial. To leave CHEMCAD, close the Word window, and then close the
Simulation window. You will be asked if you want to save the work you have done on this job, answer
yes. The input and output will then be saved in a file called Batchdis.ccx which will be stored in a
subdirectory called Batchdis located within the main directory CC5DATA. You will then be returned to
the Top Level Window. Close this window as well and you will be returned to the operating system.
SUMMARY
106
CHEMCAD Version 5.4 User’s Guide
There are ten basic steps involved in preparing, running, and documenting a process simulation in CC-
STEADY STATE. These are:
1. Starting a new job
2. Selecting engineering units
3. Creating a flowsheet
4. Selecting components
5. Selecting thermodynamic options
6. Inputting feed (and cut) stream data
7. Specifying unit operations
8. Running the simulation
9. Reviewing the results
10. Producing reports and PFD’s
These steps do not have to be performed in this order nor do all of them have to be completed for each
flowsheet. All should be considered for each problem.
There are a series of Help facilities available throughout the program. The bottom line of the screen
provides a one-sentence description of the current highlighted item. The Help command provides
access to the On-line Manual, which contains comprehensive technical information. The [F1] key
provides context sensitive help (place the cursor in a specific field and press the [F1] key). The Coach
facility will provide instructions on how to perform selected tasks. Use of these help facilities will ease
your way through the program.
CHEMCAD is object oriented. Therefore, most input and editing can be done by left or right clicking the
object of the operation, as well as by using the menu commands.
All stream and unit operations specifications (input) are accomplished using dialog boxes. These dialog
boxes are context specific and employ some combination of character fields, combo boxes, choice
boxes and check boxes.
Major program activities are organized around the following features:
• The Menu Bar
• The Graphics Palette
• The Toolbar
• Microsoft Word (reports are displayed in Word)
• Microsoft Wordpad (View command results are displayed in Wordpad)
• The Plot Window(s)
See also:
107
User’s Guide CHEMCAD Version 5.4
CHEMCAD keeps track of flowsheet data by storing it in a set of files named 〈Jobname〉.xxx. The
extension is a function of the type of information stored in the file. These files are stored in a
subdirectory called 〈Jobname〉 under the working directory. When a new job is started, CHEMCAD
opens this subdirectory and uses it as the current directory. See “How to Start a New Job” for
procedural details.
Note: In the default condition the working directory is a folder called CC5DATA off the root directory.
The user can change this by giving a different name at installation or by using the File\Switch Work
Folder command in the Top Level Window.
A new job is started from the Top Level window using the File command on the Top-Level menu bar.
Standard Windows file naming and management conventions are used. CHEMCAD creates the new
subdirectory (mentioned above), and opens the job by moving into the Simulation window. This is the
main working window of the program.
STEP 2: SELECTING ENGINEERING UNITS
The default set of engineering units used in CHEMCAD is the English system (°F, psia, lb-moles, etc.).
The user may change the engineering units using the Engineering Units option under the Format
command on the main menu bar. The standard engineering system English, SI, Alternate SI, and Metric
are available or units selections may be made item by item.
Internal units used inside CHEMCAD are °R, psia, Btu, lb-moles, feet and hours. All internal CHEMCAD
functions use these units. However, CHEMCAD automatically converts all displayed units to the current
profile.
For a detailed description of the procedure for changing engineering units see “How to Select
Flowsheet Engineering Units”.
Tip: If user input/output data is not in the same engineering format (i.e. temperatures
must be input in °C and °F for the same job), the CHEMCAD Suite has a very
convenient online unit converter. This tool is activated when the user presses the
[F6] key in fields of UnitOp dialog boxes and stream edit screens. To use this
feature the user should:
! Place the cursor in the input field, press the [F6] key and the appropriate list of
units will appear.
! Input the value in the desired engineering unit field.
! Press [Enter]. The program will convert the value in the different units available.
! Press [OK] .The value input by the user will be input into the field in the current
engineering unit profile.
108
CHEMCAD Version 5.4 User’s Guide
To simulate a flowsheet it is, of course, necessary to define the flowsheet. In CHEMCAD, this is done
graphically by selecting unit operations models (called UnitOps) from the library, placing these on the
flowsheet, then connecting them with streams. This creates an object-oriented drawing around which
the flowsheet specification is organized.
Flowsheet creation can only be done in the Edit Flowsheet mode. The presence of the graphics palette
indicates that you are in this mode. Whenever you start a new job, CHEMCAD automatically places you
in this mode. To switch out of it (into the Simulation mode) click the Run Simulation command on the
menu bar or the S/G power button on the Toolbar.
All graphics functions are performed using the palette. For a full description of these commands and
their use, see “How to Draw a Flowsheet”.
STEP 4: SELECTING COMPONENTS
CHEMCAD is supplied with a physical properties database of about 2000 components. These
components range from hydrocarbons, to chemicals, to ions, to solids. The data is gathered from a
variety of literature sources. All components have enough data stored to model the types of applications
for which they were intended, but no component stores data for every physical properties item in the
database. The user may review the data stored for each component using
ThermoPhysical\Databank\View-Edit command.
The user cannot change data in the CHEMCAD physical properties database. If the user wishes to edit
the CHEMCAD supplied component data, he/she must first copy the data into a local user database
where it will be assigned a new ID number. Data stored under the new ID numbers can be edited using
the View-Edit Properties option mentioned above.
If data for a given component is not available in the CHEMCAD database, the user has the following
options:
1. Look up and enter the data manually using the View-Edit Properties option mentioned above.
2. Instruct CHEMCAD to estimate the properties using either the pseudo-component (hydrocarbon) or
the group contribution (chemicals) methods. These options can be exercised using the New
Component option on the Databank menu under the ThermoPhysical command on the menu bar.
3. Regress raw data using the Pure Regression option under the Tools command.
The physical properties data supplied in this fashion will always be stored in one of the user databanks.
To facilitate physical properties data management on the organizational level, the CHEMCAD Suite
recognizes three types of physical properties databanks: the CHEMCAD databank, the local user
databank, and the organizational (central) pool databank. The CHEMCAD databank is located in the
CC5 directory.
User databanks are located either in the CC5DATA directory or in the flowsheet subdirectory. The pool
databank is located in the CC5 (CHEMCAD program) directory on the LAN server. Components stored
in the CHEMCAD databank have ID numbers from 1 – 5,000. Those in the pool databank have ID
numbers from 6,001 – 8,000. Those in the local user databanks have ID numbers from 8,001 - 9,999.
The ID numbers 5,001 – 6,000 are reserved for pseudo-components generated from distillation curves.
109
User’s Guide CHEMCAD Version 5.4
Components are selected for a particular job using the Component List dialog box. By selecting the
Component List option under the ThermoPhysical command on the menu bar.
See “How to Select Components for the Component List” for details.
STEP 5: SELECTING THERMODYNAMIC OPTIONS
The phase equilibrium behavior of mixtures is simulated using K-value and enthalpy (H) models. The
proper K-value and H models for a given application depend upon the nature of the solutions (both vapor
and liquid) formed at the system temperature and pressure. This in turn depends upon the components
in those solutions. CHEMCAD offers a variety of K and H models to handle a wide range of mixtures.
Applications include ideal and regular solutions, polar solutions, electrolytes, polymer-solvent mixtures,
vapor phase association, miscibility gaps, crystallization, and supercritical extraction among others.
K-value models include:
• Equations-of-state
• Activity coefficient models
• Vapor pressure models
• Electrolyte models
• Empirical models
• Special models for polymers, sour water, amines, glycol’s, etc.
Enthalpy models include:
• Equations-of state
• Latent heat
• Electrolyte
• Heat of mixing
• Empirical methods
• Special systems
The user may add his/her own K and/or H models if desired.
To assist the user in making K and H model selections, CHEMCAD provides the ThermoWizard option,
which is automatically launched when the user first selects the components for the job but can also be
found under the ThermoPhysical command on the menu bar.
K-value and enthalpy model selections are made using the K-value Options dialog box and the
Enthalpy Options dialog box respectively. These dialog boxes are called by selecting the K-value and
Enthalpy options under the ThermoPhysical command on the menu bar. Please see “How to Select
K-value Options” and “How to Select Enthalpy Options” for details.
Many K-value methods require the use of fitting parameters called BIPs (binary interaction parameters)
to achieve adequate accuracy. BIPs quantify the interactions between two different compounds. These
must be correlated with experimental data using a regression facility. For certain equations (NRTL,
UNIQUAC, Wilson, SRK, Peng-Robinson, BWRS, ESD, SAFT, MNRTL and Pitzer) CHEMCAD
maintains a database of BIP’s. It is not practical, however, for this database to support the universe of
110
CHEMCAD Version 5.4 User’s Guide
possible combinations of molecules. Therefore, CHEMCAD provides two facilities for handling gaps in
BIP data:
1. Equilibrium data regression facilities. These are found under the BIP Regression and Electrolyte
(Regression) options under the Tools command on the menu bar.
2. Activity coefficient estimation using the UNIFAC group contribution method.
STEP 6: INPUTTING FEED (AND CUT) STREAM DATA
In any simulation problem, all feed streams must be completely defined before the calculation can begin.
For a stream to be completely defined there must be enough information present to calculate the
enthalpy. For mixtures, this requires the composition plus any two of the temperature, pressure, or
vapor fraction. For pure components that are superheated or subcooled, temperature and pressure
must be specified. For pure components that are saturated or two phases, it is necessary to define the
composition and the vapor fraction plus either the temperature or the pressure. By convention,
CHEMCAD does not permit the user to input the enthalpy of a stream.*
Total stream flowrates are defined in one of two ways.
1. If the composition is given in mole fractions, mass fractions, or volume fractions, then the user must
enter the total flowrate.
2. If the composition is given in any other units, then the total flowrate is the sum of the component
flowrates.
In certain simulation problems the cut streams must be defined or convergence cannot be achieved.
This normally occurs when the cut stream (or some stream down stream of it) feeds a unit operation,
which cannot converge if its inlet is empty. For example, if the top stream to a reboiled absorber is a
recycle cut stream, then the absorber will not be able to converge during the first recycle iteration unless
an estimate of this stream is given. This in turn leads to convergence failure for the recycle loop itself.
Feed streams and cut streams are both entered using the Edit Streams dialog box. This dialog box is
called by double clicking on the stream while in the Simulation Mode.
See also: “How to Define Feed Streams”.
* There is one exception to this rule. If all other fields are blank (i.e., composition, T,
P, and V/F are not given), then the enthalpy may be specified. This is useful for
defining heat duties in certain situations.
STEP 7: SPECIFYING UNIT OPERATIONS
Unit operations models (or UnitOps) represent process equipment. These UnitOps receive feed or
materials data from their inlet streams, operate on those streams by executing their equations, and then
write the results to their outlet streams and, in the case of non-stream results, to its UnitOps parameter
list. Since CHEMCAD UnitOps are flexible in their capabilities, the user must tell the program exactly
how each is to operate by defining certain input parameters. These parameters are entered using a
dialog box specific to the UnitOp, and are saved by the program in the same parameter list mentioned
above. This parameter list, together with its inlet and outlet streams contains all of the information, both
input and output, associated with a particular UnitOp.
111
User’s Guide CHEMCAD Version 5.4
With a few exceptions, each unit operation adds one or more degrees of freedom to the calculation when
it is placed on the flowsheet. Each degree of freedom requires the user to make one (non-pressure)
specification in order for a unique solution to exist. Since CHEMCAD is a modular sequential simulator,
it requires that specifications be made in the UnitOp, which added the degree-of-freedom. For example,
an HTXR (heat exchanger) unit adds one degree-of-freedom to the flowsheet, so one specification must
be made in the HTXR dialog box.
Some UnitOps create a different number of degrees of freedom in different situations. CHEMCAD
knows how many specifications are required for each UnitOp in all situations. It will tell you if you are
under or over specified when you try to save the UnitOp data.
The complete CHEMCAD process simulation suite provides a library of about 60 unit operations. The
user may add his/her own UnitOps to the library as desired.
For the details of UnitOps input, see “How to Specify Unit Operations”.
STEP 8: RUNNING THE SIMULATION
Simulation results are reviewed interactively using the Results and Plot commands on the menu bar.
The Results command displays results in tabular text format. All Results displays are in Wordpad. The
Plot command displays results in graphical format in a graphics-editing window. The available types of
information and the basic layout of that information are determined by CHEMCAD. The specific
information and its specific format are user specified.
Results outputs are displayed in Wordpad and can be printed from that program. Plot results are sent
to a plot window and may be printed to available printers using the CHEMCAD print facilities.
See also:
• “How to View Stream Compositions”
• “How to View Stream Properties”
• “How to Plot”
112
CHEMCAD Version 5.4 User’s Guide
For the purposes of formal documentation, the CHEMCAD Suite offers two facilities: the Report and the
PFD. The Report is for tabulated results. The PFD (Process Flow Diagram) is a drawing, which displays
the flowsheet heat and material balance, and any additional information the user desires.
See also:
• “How to Create Reports”
• “How to Create PFDs”
COACH
In order to make the use of the program easier, besides Help, CHEMCAD provides the user with an on-
line assistant called “Coach”. Coach is accessed by using the Help command. When this is done the
screen splits as shown:
Selecting one of the options at the right will display a set of instructions for performing the desired
operations. If the first level of instructions is not detailed enough, the user may click on any of the
instructions listed and a more detailed explanation of how to perform that step will appear. It is also easy
to move back and forth through the display hierarchy.
Coach facilities are provided for all of the major features of CHEMCAD.
113
User’s Guide CHEMCAD Version 5.4
GETTING STARTED
The first time you run CHEMCAD, a “Report Viewer Setting” screen will appear as shown below:
This screen allows you to specify where reports are sent. You must locate the programs on your
machine using the Browse buttons. For reports, you may use either Microsoft Word or WordPad. For
viewing smaller data output (like stream data, tower profiles, etc.), you may only use Microsoft WordPad.
First, click the Browse button for the report viewer. This will bring up a dialog box similar to this one:
From this screen, you can navigate (by clicking on the appropriate drive/folder) until you reach the
correct directory. For Microsoft Word, this is typically \Program Files\Microsoft Office\. For Microsoft
Wordpad, this is typically \Program Files\Accessories\. Once you see the Microsoft Word or Wordpad
shortcut, double click it to select it. You will return to the Report Viewer Setting dialog box. Repeat the
procedure for the simple file viewer and you are finished.
114
CHEMCAD Version 5.4 User’s Guide
Title Bar
Menu Bar
Toolbar
Status Bar
The top line is called the Title Bar. It contains the CHEMCAD logo and name on the left side, and the
WINDOWS minimize, tile, and close buttons on the right side.
The next line is called the Menu Bar. This bar contains the top-level commands for CHEMCAD. They
are:
File This command is used to open jobs, create new jobs, access print and
report setup, and manage the license configuration.
License This command is used to configure license, update dongles, authorize
special licenses.
View This command is used to turn on and off the tool and status bars.
Help This command is used to access CHEMCAD’s help system.
The third line (or bar) is called the Tool Bar. It contains the symbols to directly invoke short cuts to
various file functions that would otherwise be accessed through the menus.
The white area, which constitutes most of the screen space, is inactive at this level, but contains the
license agreement for CHEMCAD. It is important that you read and understand this agreement.
The last line of the CHEMCAD window is called the Status Bar.
The Top Level Window is only one of the windows available in the program. CHEMCAD’s menu
structure changes when you load or create a job. In the course of this tutorial, you will be introduced to
the most important of these menu functions and their use.
115
User’s Guide CHEMCAD Version 5.4
To start a new job you must select the New Job function on the File menu (or click the New Job button
on the toolbar), specify a name to save the job under, and click the Save button. When this is done, you
are ready to begin working in your new job and its flowsheet.
BRIEFLY
New Job
1. Call the New Job dialog box. There are two ways to do this:
a. From the Top Level Window menu bar. The File command is used for this. To open the File
menu, you may:
• Click the File command, or
• Push [ALT + F]
116
CHEMCAD Version 5.4 User’s Guide
To select engineering units for a flowsheet, you must select the menu option Format and then select the
option Engineering Units. This will bring up the following dialog box:
117
User’s Guide CHEMCAD Version 5.4
2. Select the Engineering Units option from this menu. The Engineering Units Selection dialog
box will open.
3. Press one of the four buttons, English, ALT SI, SI, or Metric. Any of these buttons will
automatically reset all of the options on the page to the selected profile.
118
CHEMCAD Version 5.4 User’s Guide
Engineering
Units
Profiles
To select or change engineering units one by one, you must select the unit that you would like to change
by clicking the drop down menu box you intend to change. When this occurs you will be presented with
a list of alternatives, and you simply click on the units of your choice. For example with Mass/Mole:
Options
Make all of the necessary edits in this manner. When all desired selections have been made, close the
dialog box by clicking the [OK] button.
Note: If you click one of the pre-defined profile buttons after you have made
changes to individual unit settings, you will lose the changes you made.
CREATE A DEFAULT ENGINEERING UNITS PROFILE
If you would like to create an engineering units profile that you can use in all or some of your other jobs,
you may do so in the following manner.
119
User’s Guide CHEMCAD Version 5.4
If you would like to create an engineering units profile that you can use in all or some of your other jobs,
you may do so in the following manner.
1. Select the Engineering Units Selection dialog box as detailed above.
2. Make the appropriate changes to the engineering units using the method described above.
3. Enter the name of the profile into the field next to the Save Profile button.
4. Click the Save Profile button to save the profile. The new profile is now saved and available for
future use. You may exit the screen now by pressing the Save button.
5. The next time you want to use the profile you created here, you simply go to the Engineering Units
Selection dialog box, enter the name of the profile in the field next to the Save Profile button, and
then select the Load Profile button.
120
CHEMCAD Version 5.4 User’s Guide
This section will be concerned only with those graphics commands and features that are used to draw,
embellish, and edit the flowsheet.
The main graphics features and concepts of the Edit Flowsheet Mode are:
1. The primary tool for drawing flowsheets is the Main Palette. It contains the UnitOp icons, the
stream drawing function, the text function, and several other graphic facilities.
2. To use the Main Palette, you must be in the Edit Flowsheet mode. Being in the Edit Flowsheet
mode also activates several other drawing capabilities.
3. Other menu bar commands which are sometimes used in the process of drawing and editing
flowsheets are:
• The Edit command which provides the functions Redraw, Undo, Redo, Cut, Copy, Paste,
Delete, Select All, Create DXF, Metafile to Clipboard, and Symbol Builder.
• The View command, which provides the functions, Zoom, Toolbar, Status Bar, Main Palette,
Grid Visible, Change Grid Size, Show Page Bounds, and Stretch Proportionately.
• The Format command containing Bring to Front, Send to Back, Fill Pattern, Pen Style,
Arrowheads, Color, Font, Align, and Import Bitmap.
4. Object oriented graphics editing capabilities are accessed using the Edit Object menu. You open
this menu by right clicking on the object to be edited.
GRAPHICS FEATURES OF THE PLOT WINDOW
You enter a plot window from the Simulation Window using the Plot command. This means you never
enter an empty plot window. There is always a display present and the purpose of the Plot Window is
to enable us to view and edit the plot.
The main features of the Plot Window are:
1. The menu bar offers the following graphics commands:
• The Edit command, which provides the functions Undo, Cut, Copy, and Paste.
• The View command, which enables the user to toggle the Toolbar, and the Status Bar on and
off.
• The Graph command which contains the Edit, Zoom Out, log Y, log X, linear Y, linear X, Data
to EXCEL CSV file, Data to EXCEL (; delimeter), Hide data points, Show data points, and Edit
titles commands.
2. Zooming is done differently in the Plot Window. Please refer to the section on How to create a
plot to learn how to use this feature.
3. Plot editing, other than changing labels and titles, is done using the Chart Explorer which is
accessed via the Graph command on the menu bar. The Chart title, x axis title, and y axis title may
be changed using the Graph\Edit titles command.
USING THE PFD WINDOW
The PFD Window is used to create process flow diagrams.
The main features of the PFD Window are:
121
User’s Guide CHEMCAD Version 5.4
1. The process flow diagram always starts with the flowsheet just as it is in the Simulation Window.
2. The flowsheet in the PFD Window is treated as a collection of objects, not as a single object as in
past versions of CHEMCAD. This means that the objects may be individually moved, stretched, and
rotated just as in other windows.
3. Special functions are provided to enable the user to quickly and easily place customized stream
data boxes and UnitOp data boxes on the drawing. These functions are found under the Format
command on the menu bar when the Main PFD option is selected from the Output menu.
4. A special PFD Palette is provided to enable the user to draw and place text on the PFD. This
palette is accessed when the Main PFD option is selected from the Output menu.
5. The Edit command on the menu bar provides the Redraw, Undo, Redo, Cut, Copy, Paste, and
Delete functions.
6. Right clicking an object in the PFD Window calls the same Edit Object menu used in the Run Edit
Flowsheet mode of the Simulation Window.
To draw a flowsheet you must be in the Edit flowsheet mode of the Simulation Window. Whenever
you start a new job, you are automatically placed in this mode. You will know you are in the Edit
flowsheet mode by the following:
1. If the fifth command (from the left) on the menu bar is the Run Simulation command, then you are
in the Edit flowsheet mode (you click the Run Simulation command to switch to the Run
Simulation mode).
2. If the Main Palette is present, you are in the Edit flowsheet mode. However, if the Main Palette is
not present, you may still be in the Edit flowsheet mode. Commands are available to hide it while
still drawing the flowsheet.
While in this mode, certain commands and functions will be available which are unique to drawing
flowsheets. These are:
1. The Edit Object menu (obtained by right clicking an object), presents a different set of commands.
Edit Object commands in the Edit Flowsheet mode are strictly graphics oriented, while these
same commands in the Run Simulation mode are strictly simulation oriented.
2. More Edit commands are available in the Edit Flowsheet mode.
3. The ThermoPhysical, Specifications, Run, Results, Plot, Output, Sizing, and Tools commands
are restricted in the Edit Flowsheet mode.
The graphics palette is used to select unit operation icons, draw streams, create objects, put text on the
drawing, and generally perform the creation of the flowsheet. The Main Palette is displayed only when
you are in Edit Flowsheet Mode.
122
CHEMCAD Version 5.4 User’s Guide
In addition, you should note the following about the Main Palette:
• Pointing to a box with the cursor will causes a small descriptive label to appear which will
indicate to you what each box represents.
• Pointing to a box and clicking with the left button of the mouse will activate the corresponding
function. For instance, to place a heat exchanger UnitOp icon on the flowsheet, you start by
clicking on the heat exchanger square.
123
User’s Guide CHEMCAD Version 5.4
• Pointing to a box and clicking with the right button of the mouse will cause a sub-palette of icon
options to be displayed. Right clicking again (on the same master palette box) will cause the
sub-palette to disappear.
• The master palette may be switched on and off using the View/Main Palette command, or by
switching to Run Simulation mode.
• The size and shape of the main palette can be controlled using the View/Palette Settings
command.
• On the icon display, inlets are indicated by small blue squares and outlets by small red squares.
SUB-PALETTES
Since each unit operation can be represented by more than one icon, each unit operation square on the
Main Palette has one or more sub-palettes from which the icon options can be selected. Sub-palettes
are called by right clicking on the appropriate square on the Main Palette. Therefore, to view all of the
available heat exchanger icons, you would first point with the cursor to the heat exchanger square on the
Main Palette, then press the right mouse button. Then all available heat exchanger sub-palettes will
appear.
Rotate Objects
Right-click the
heat exchanger
square
124
CHEMCAD Version 5.4 User’s Guide
If user added icons exist, then they will appear in a second sub-palette and both sub-palettes will appear.
The desired UnitOp icon is selected by left clicking on the appropriate square of the sub-palette.
It is possible to have sub-palettes from different unit operations displayed at the same time. There is no
limit to the number of sub-palettes, which may be simultaneously displayed.
The sub-palette(s) disappears when:
• A selection is made from it; or
• The user right clicks on the same square or the Main Palette, which made the sub-palette
appear.
Sometimes the icon displayed on the Main Palette is the icon the user wants to use. In this case it is not
necessary to call the sub-palette(s). Simply left click the desired square and place the icon on the
flowsheet.
THE SIZE AND SHAPE OF THE PALETTES
The user may specify the size and shape of the main and sub palettes by following this procedure:
1. Click the View command on the menu bar.
2. The View Menu appears, select the Palette Settings option;
3. The Palette Settings dialog box will appear like so:
Specifies initial
sub-palette
position
Specifies number
of columns on Specifies number
the Main Palette of columns of the
sub-palettes
Using these options, the user can make the palettes square or thin, small or large, etc.
HIDING AND CALLING THE PALETTES
The Graphics Palette can be switched on and off in four ways. These are:
1. By switching in and out of the Edit Flowsheet Mode using the Edit Flowsheet/Run Simulation
command on the menu bar. If the command Run Simulation is currently displayed, then the
program is in the Edit Flowsheet Mode. Clicking on the Run Simulation command will switch the
program into the Run Simulation Mode. When this occurs the Run Simulation command will
disappear from the menu bar and the Edit Flowsheet command will appear in its place.
125
User’s Guide CHEMCAD Version 5.4
2. By switching in and out of the Edit Flowsheet Mode using the S/G button on the toolbar. If the
command Run Simulation is currently displayed on the menu bar, then the program is in the Edit
Flowsheet Mode. Clicking on the S/G button will switch the program into the Run Simulation
Mode. When this occurs, the Run Simulation command will disappear from the menu bar and the
Edit Flowsheet command will appear in its place.
3. The palette can be switched on and off while remaining in the Edit Flowsheet Mode using the
Component Palettes button on the toolbar.
4. The palette can be switched on and off while remaining in the Edit Flowsheet Mode using the
View/Main Palette, that is:
• Click the View command on the menu bar. The View menu will appear.
• Toggle the palette on and off by clicking on the Main Palette option. The presence of a check
mark by the Main Palette option indicates that the palette is “on”, i.e., to be displayed. If the
check mark is absent, then the palette is to be hidden even while in the Edit Flowsheet Mode.
MOVING THE PALETTES
Palettes in CHEMCAD can be moved like a Windows dialog box. Specifically; to move a palette,
1. Point to the solid bar across the top of the palette,
2. While holding down the left mouse button, drag the palette to the new position.
DRAWING LINES
Procedure:
1. Open the graphics palette.
2. Click on the Line square on the palette. The palette will close and the drawing cursor will appear.
3. Point to the starting point of the line segment.
4. While holding down the left mouse button, drag the cursor to the end point of the line.
126
CHEMCAD Version 5.4 User’s Guide
5. Release the mouse button. The line will be complete and the palette will reopen.
DRAWING RECTANGLES
Procedure:
1. Open the graphics palette.
2. Click on the Rectangle square on palette. The drawing cursor will appear and the palette will close.
3. Point to one corner of the rectangle.
4. While holding down the left mouse button, drag the cursor to the opposite corner of the rectangle.
5. Release the mouse button. The rectangle will be complete and the palette will reopen.
DRAWING ELLIPSES
Procedure:
1. Open the graphics palette.
2. Click on the Ellipse square on palette. The drawing cursor will appear and the palette will close.
3. Point to the location of one end of the ellipse or ellipse segment.
4. While holding down the left button on the mouse, move the mouse around until the ellipse is the size
and shape desired.
5. Release the mouse button. The ellipse will be complete and the palette will reopen.
DRAWING POLYLINES
Procedure:
1. Open the graphics palette.
2. Click on the Multiline square of the palette. The drawing cursor will appear and the palette will
close.
3. Point to the starting point of the first line segment and click one time.
4. Move the cursor to the end point of the first line segment and click one time. The first line segment
will be complete.
5. Move the cursor to the end point of the second line segment and click one time. The second line
segment will be complete.
6. Repeat step 5 for all but the last segment.
7. For the last line segment, point to the end point and double click. The polyline will be complete and
the palette will reopen.
DRAWING POLYGONS
Procedure:
1. Open the graphics palette.
127
User’s Guide CHEMCAD Version 5.4
2. Click on the Polygon square of the palette. The drawing cursor will appear and the palette will
close.
3. Point to the starting point of the first line segment of the polygon and click one time.
4. Move the cursor to the end point of the first line segment and click one time. The first line segment
will be complete.
5. Move the cursor to the end point of the second line segment and click one time. The second line
segment will be complete and a line will appear between the end point of the second segment and
the starting point of the first segment.
6. Repeat step 5 for all but the last segment.
7. For the last line segment, point to the end point and double click. The polygon will be complete and
the palette will reopen.
TEXT
Refer to the section “How to place text on a drawing”.
Text may be placed on a flowsheet or PFD using the text facility on the graphics palette.
Text
128
CHEMCAD Version 5.4 User’s Guide
The Format command is used to specify the style and color of certain graphics objects used in
CHEMCAD. It is also used to import bitmaps into CHEMCAD drawings. Selecting the Format
command will open the Format menu that offers the following graphics features:
Bring to Front Places an object in the foreground.
Send to Back Places an object in the background.
Fill pattern When a closed object is drawn, the internal area of that object can have
a user selected fill pattern. This command is used for that purpose.
Pen style For selecting the pattern(s) to be used to create text and draw lines,
circles, etc.
Arrowheads User drawn lines may have arrowheads attached to them in a variety of
ways. This command enables the user to specify which arrowhead
method is to be used.
Color Controls the color of text, lines, foreground and background.
Font Controls text font (style) selection.
Align Helps position UnitOp symbols on the screen.
Import bitmap For using externally created graphics objects within CHEMCAD. This is
useful for importing logos, title blocks, etc.
Add Stream Box For putting a table of selected stream compositions, flows, and/or
properties on a PDF.
Add UnitOp Box For putting a table of parameters and calculated values associated with
a unit operation on the PDF.
Add TP Box For putting boxes containing temperature, pressure, and/or flowrate on
the streams of a PDF.
The Format Menu commands Engineering Units, Add Stream Box, Add UnitOp Box, Add TP Box
are discussed elsewhere because they do not apply to drawing a flowsheet.
BRING TO FRONT
When an object is in the "front", it will be superimposed over any other objects occupying the same
space.
SEND TO BACK
When an object is in the "back", it will be covered up if any other object occupies the same space on the
screen.
129
User’s Guide CHEMCAD Version 5.4
FILL PATTERN
The internal area of a closed drawn object may be filled with a hatching pattern of the user’s choice. The
user may choose from any of the following options:
Changing fill patterns does not change the fill pattern of those objects, which have already been drawn.
It only specifies the fill pattern to be used when drawing new objects.
PEN STYLE
Lines, circles, squares, etc. are drawn with a pen or line style, which the user can control.
Options are:
ARROWHEADS
Lines, circles, etc. may be drawn with any of the following user specified arrowheads:
COLOR
Selecting this command calls the Color menu. This menu allows the user to:
• Select the pen color: The pen color is the primary line color. Since all filled objects are drawn
with a line, the pen color is also the primary color of the line forming the border of closed
objects. The word “primary” is used because where lines are not solid (i.e., where they are
made of dashes and dots), the pen color is the color of the dots and dashes themselves, and
the fill color is the color of the spaces between the dots and dashes.
The available pen colors are presented in a standard Windows Color Selection dialog box. The
user makes his/her selection by clicking on the desired color. A dashed line around the active
(selected) color indicates color selections. Use of custom colors is also possible.
130
CHEMCAD Version 5.4 User’s Guide
• Select the Foreground Fill Color: The foreground fill color defines the internal color of solid
closed objects. The available fill colors are presented in a dialog box similar to that described
above for pen colors.
• Select the Background Fill Pattern: The background fill color defines the color of all areas not
bound as solid closed objects or lines such as text, lines, semi-circles, etc. The available fill
colors are presented in a dialog box similar to that described above for pen colors.
This command is used to align UnitOp symbols relative to each other. It only works before the UnitOps
have been connected by streams. After a stream has been added to the flowsheet, the Align command
is inoperative.
IMPORT BITMAP
Bit maps may be placed on a drawing using the Format command on the menu bar. The procedure is
as follows:
131
User’s Guide CHEMCAD Version 5.4
1. Click on the Format command on the menu bar. The Format menu will open.
2. Select the Import Bitmap option on the Format menu. The Open dialog box will open.
3. Identify the bit map file that is to be imported.
4. When the file name is displayed in the File name: field of the Open dialog box, click on the [Open]
button. The dialog box will close and the bit map object will be placed just to the right of the existing
flowsheet.
5. Click on the area just to the right of the flowsheet. The four object selection boxes will appear at the
corners of the bit map. The bit map is now an object within CHEMCAD and can be manipulated like
any other object.
Certain objects within CHEMCAD can be rotated through any angle using the Rotate function on the
palette. All CHEMCAD objects can be so rotated except for streams and text. Imported objects such as
bit maps cannot be rotated.
The procedure for rotating an object is:
1. Click on the Rotate square on the palette. The palette will close and the rotate cursor will appear.
2. Point to the object that is to be rotated and hold down the left mouse button. A dotted rectangle will
appear around the periphery of the object and the four selection boxes will appear at its corners.
3. Keeping the left mouse button depressed, move the mouse around. The dotted rectangle will rotate
to indicate the new position of the objects.
4. When the final angle of rotation has been identified, release the mouse button. The object will rotate
to its new position. All streams attached to it will also rotate.
To move an object:
• Place the mouse arrow in the object
• Hold down the left button on the mouse. The four object boxes will appear
• With the left mouse button held down, roll the mouse and move the object to its new location,
then release the left button of the mouse. The object position will be changed.
MOVING MULTIPLE OBJECTS
132
CHEMCAD Version 5.4 User’s Guide
• Select the objects to be moved. Refer to “Selecting Objects” to learn how to select multiple
objects.
• Move the cursor to a position over one of the selected objects.
• Keeping the left mouse button depressed, move the mouse around. The selected objects will move
with it, while the rest of the objects remain in place.
• When the objects are in their final positions, release the mouse button.
PANNING THE FLOWSHEET
To resize an object; left click the object to select the object. The four corner object boxes will appear.
Place the arrow on one of the boxes. Hold down the left button of the mouse; and roll the mouse. The
object will change size.
DELETING
There are two ways to delete and object: right click the object with the mouse to open the Edit Object
menu and then select the Delete option, or by pressing the D key.
FLIPPING AN OBJECT’S Y-AXIS
! !
Original Flipped
To do this, open the Edit Object menu by right clicking that object with the mouse. Then select the Flip
Vertical Y axis option by clicking it with the mouse or by pressing the [V] key. Immediately upon
selection, the object will flip.
133
User’s Guide CHEMCAD Version 5.4
The metafile will copy the entire flowsheet to the clipboard. The procedure is:
1. Click on the Edit command on the menu bar. The Edit menu will open.
2. Select the MetaFile to clipboard option from the Edit menu. The flowsheet will be copied to the
clipboard.
USING THE COPY COMMAND
The copy command will copy selected objects to the clipboard. To use the copy command:
1. Select the objects to be copied. Refer to the “Selecting Objects” section of this Users Guide if you
do not know how to select multiple objects.
2. Click on the Edit command on the menu bar. The Edit menu will open.
3. Select the Copy command from the Edit menu. The selected objects will be copied to the
clipboard.
Flowsheet creation involves placing unit operations on the screen and connecting them with streams.
The flowsheet specifies the equipment equations to be solved and what order they are to be solved.
Drawing a flowsheet involves the following steps:
1. Enter the Edit Flowsheet mode.
2. Place UnitOps on the flowsheet.
3. Connect the UnitOps with Streams.
4. Place text and symbols on the drawing (optional)
STEP 1: ENTER THE EDIT FLOWSHEET MODE
The Edit Flowsheet mode is the CHEMCAD graphics-editing facility specifically designed for drawing
flowsheets. If you are starting a new flowsheet, you will automatically be in the Edit Flowsheet mode
when you start a new job. If you are adding to an existing flowsheet, you may have to switch to this
mode by clicking the Edit Flowsheet command or the S/G button. Either way, whenever you enter the
Edit Flowsheet mode the Main Palette will appear.
134
CHEMCAD Version 5.4 User’s Guide
Each tile contains a symbol that indicates its function. Most of them represent unit operation icons, but
others enable the user to:
• Draw streams
• Place text on the drawing
• Draw objects (rectangles, circles, lines, etc.)
• Rotate objects already on the drawing and
• Re-invoke the arrow cursor
In addition to the palette you will also be using the View command whenever you are drawing flowsheet.
The View command is located on the menu bar and enables you to control a wide range of graphics
functions.
When you click the View command, a menu with the following options will open:
• Zoom Options– To zoom in and out on the flowsheet.
• Toolbar – To switch the toolbar on and off.
• Status bar – To switch the status bar on and off.
• Main Palette – To switch all open palettes on and off while remaining in the Edit Flowsheet
mode.
• Palette Settings – To specify the size and dimensions of the palettes.
• Grid Visible – To turn the drawing grid on and off.
• Change Grid Size – To specify the grid size.
• Show Page Bounds – Turns the page boundaries on and off.
• Adjust Page Size – Adjust the size of the total available drawing area.
135
User’s Guide CHEMCAD Version 5.4
• Stretch Symbol Proportionately – Forces CHEMCAD to stretch the height and width by the
same percentage amount whenever an object is resized.
• Refresh Data Boxes – Updates the Stream, UnitOp, and TP boxes.
• TP Box Visible – Switches the TP boxes on and off.
The details of these commands are explained elsewhere in this guide.
Also available are the following toolbar buttons (from left to right across the toolbar):
New Closes the existing flowsheet and starts a new one.
Open Closes the existing flowsheet and opens another one.
Save Saves the flowsheet and all information associated with it.
Cut Deletes selected objects and places them on the clipboard.
Copy Copies selected objects to the clipboard.
Paste This power button is currently inoperative.
Print Print the flowsheet.
Zoom % Zoom in (or out) a specified percent on (or from) the drawing center.
Zoom In To zoom in on a specific area of the flowsheet.
Zoom out To zoom out a previous view or to 50% of the current view.
Zoom to Fit Zooms so that the entire flowsheet exactly fits on the screen.
Zoom In at a Point Zoom in a fixed percent at a specified location on the flowsheet.
Zoom Out at a Zoom out a fixed percent from a specified location on the flowsheet.
Point
Zoom Rectangle Zoom in on the area enclosed in a user drawn rectangle.
Pan Overview Pan the entire flowsheet
Graphics Palette Turns the palette(s) on and off even when you are in Edit Flowsheet mode.
S/G Closes the Edit Flowsheet mode and returns to the Simulation mode.
These are the tools available to create, edit, review, and print a flowsheet.
STEP 2: PLACE UNITOPS ON THE FLOWSHEET
Each unit operations model is represented on the flowsheet by one or more UnitOp icons. The
CHEMCAD Suite supplies a set of “standard” UnitOp icons, but users can create their own. All available
UnitOp icons are given a name, attached to a specific Unit Operations model, and included in the main
palette. This palette is called using the commands and buttons mentioned above.
Once a UnitOp icon is placed on the flowsheet, it becomes an object. All objects can be moved and
modified using standard Windows conventions.
136
CHEMCAD Version 5.4 User’s Guide
When a UnitOp is placed on the flowsheet, CHEMCAD automatically assigns it an ID number and a
label. ID numbers are numbered sequentially from 1 and are set inside a small circle that is always
placed just to the upper left of the icon. Labels, which may be up to 12 characters, are blank in the
default condition, and are placed just above the UnitOp number circle. ID numbers and labels are
objects themselves and can be moved and edited independently of their UnitOp icon and of each other.
However, ID number and label positions are considered by CHEMCAD to be relative to the UnitOp icon
itself. Therefore, moving a UnitOp icon also moves its ID number and label so as to maintain their
positions relative to the UnitOp.
For procedural details on adding UnitOps to a flowsheet, see:
• "How to Add UnitOps to the Flowsheet"
• "How to Move, Modify, Delete, or Duplicate Objects"
• "How to Create User Defined UnitOp Icons"
STEP 3: CONNECTING UNITOPS WITH STREAMS
A “Stream” in a process simulator is a list of numbers representing temperature, pressure, vapor fraction,
enthalpy and the molar flowrates of each of the components. They serve the following purposes:
1. They store some of the input and output for a unit operations module.
2. They connect one UnitOp to another in a particular order. In other words, the outlet stream from
one UnitOp becomes the inlet stream to another.
3. The pattern of their connectivity establishes the calculation order for the simulation.
Drawing streams on a flowsheet provides an "object" around which these functions can be organized.
In order to understand how streams are drawn in the CHEMCAD Suite, you should first understand that
every UnitOp icon consists of some combination of primitives plus “inlet” points and “outlet” points. All
streams going into a UnitOp must go to an inlet point. All streams leaving a UnitOp must come from an
outlet point. The position of these points is fixed by whoever builds the UnitOp icon. The CHEMCAD
Suite knows where these points are, which of them are inlets, and which are outlets. It will always snap
streams to one of these positions.
For convenience, the CHEMCAD Suites identifies inlet positions with blue dots and outlet points with red
dots on the UnitOps icon. When you look at the UnitOp icon on the main palette or the sub-palettes, you
will see these dots. When you place a UnitOp on the flowsheet, these dots will disappear because they
would look bad on a flowsheet drawing. Therefore, to help you find them when you are drawing a
stream, the cursor will switch a UnitOp’s dots on and will switch from a cross to a black arrow whenever
you are close to one of these inlet or outlet points. Clicking the left mouse button causes the end of the
stream to snap to the closest “lit” position.
When drawing streams, you may go from an inlet point to and outlet point or from and outlet point to an
inlet point. In both cases you begin the stream by clicking on the desired position when the black arrow
appears. To complete the stream you move the cursor (the black arrow) to an “opposite” position (if you
started the stream at an outlet point, then an inlet is an opposite position and vice versa). When you are
close to one, a label will appear describing the position. To finish the stream click the left mouse button
when this label appears. The stream will snap to this position and an ID number will be assigned to the
137
User’s Guide CHEMCAD Version 5.4
stream. This ID number can be overridden if desired by right clicking on the stream and using the Edit
ID command on the menu, which appears.
To draw a stream:
1. Click the Stream button on the main palette. The palette will disappear and a small cross will
appear as the cursor.
2. Point to the desired position on the UnitOp. When the black arrow appears at the desired position,
press the left mouse button. The cursor will snap to this position.
3. Draw the stream over to the destination UnitOp. If multiple turns are necessary, click the left mouse
button to fix horizontal and vertical anchors points.
4. Point to the position on the UnitOp icon that you want the stream to go to. When the descriptive
label appears at the desired position, click the left mouse button. The stream will snap to this
position.
5. The stream is now drawn, but the Stream cursor is still active. Therefore, draw any additional
streams required using steps 1 – 4 above.
6. When finished drawing streams, press double click on an unoccupied part of the flowsheet. The
main palette will reappear.
Once a stream is placed on the flowsheet, it becomes an object. All objects can be moved and modified
using standard Windows conventions. For additional information about drawing streams, see:
• "Drawing Streams"
STEP 4: MODIFYING AND ADDING TO THE FLOWSHEET
Beyond just placing UnitOps and connecting them with streams, it is possible to add to and change the
flowsheet in the following ways:
1. Place primitives, including text, on the screen.
2. Create and add symbols (groups of primitives) to the flowsheet.
3. Move, stretch, modify, and/or delete any object.
4. Select color and fill schemes.
5. Select line patterns.
See also:
• "How to Move, Modify, Duplicate and Delete Objects”
• "How to Put Text on a Drawing or Plot"
To add UnitOps to the flowsheet you must be in the Edit Flowsheet mode. If the Main Palette is
displayed, then you are in the Edit Flowsheet mode. If you are not in the Edit Flowsheet mode, you
138
CHEMCAD Version 5.4 User’s Guide
can get there by click the Edit Flowsheet option on the menu bar or by clicking the S/G button on the
toolbar.
Once the Main Palette is displayed, you must:
• Select a UnitOp icon from the palette, and
• Place the UnitOp icon on the flowsheet.
BRIEFLY
Call the Main Palette by switching to the Edit Flowsheet mode as explained above. Whenever you
start a new flowsheet, you will automatically be placed in this mode.
Point and click on the desired UnitOp square on the palette. The palette will disappear and a small,
square cursor will appear. This cursor is for the placement of the UnitOp icon on the flowsheet as
indicated by the one-line help at the bottom of the window.
Position the tip of the cursor where you want the icon to appear, and then click once.
DETAILS
Please note the following:
Since each unit operation can be represented by more than one icon, each unit operation square on the
Main Palette has one or more sub-palettes from which the icon options can be selected.
Sub-palettes are called by right clicking on the appropriate square on the Main Palette. Therefore, for
instance, to view all of the available heat exchanger icons, you would first point with the cursor to the
heat exchanger square on the Main Palette, and then press the right mouse button. Then all available
heat exchanger sub-palettes will appear.
If user added icons exist, then they will appear in a second sub-palette and both sub-palettes will appear.
The desired UnitOp icon is selected by left clicking on the appropriate square of the sub-palette.
It is possible to have sub-palettes from different unit operations displayed at the same time. Right
clicking on one UnitOp square, say a mixer square, and then right clicking on a different UnitOp square,
say a pump square, will cause both the mixer and pump sub-palettes to appears. There is no limit to the
number of sub-palettes, which may be simultaneously displayed.
The sub-palette disappears whenever a selection is made from it, or when the user right click on the
corresponding main palette tile again.
Sometimes the icon displayed on the Main Palette is what the user wants to use. In this case it is not
necessary to call the sub-palette. Simply left click the desired square and place the icon on the
flowsheet.
When the icon has been selected, the palette will disappear and the Add UnitOp cursor (a small square)
will appear.
139
User’s Guide CHEMCAD Version 5.4
DRAWING STREAMS
To place streams on the flowsheet click the Streams tile on the Main Palette.
Strea
m
Tile
There are a few general rules to remember when drawing streams on the flowsheet:
Each stream goes from a source unit to a destination unit.
Each unit has inlet and outlet positions. These are established when the symbol is created. The
program always snaps streams to these positions. During the simulation a process stream always
"flows" from an outlet position on a source unit to an inlet position on a destination unit. When drawing
the flowsheet, a stream may be drawn in any direction: from an inlet position to an outlet position as well
as from an outlet position to an inlet position.
When starting a stream, the cursor will be a small cross. When the cursor get near an inlet or outlet
position, this cursor will convert to a black arrow. At the same time the UnitOp inlet and outlet points will
be deployed. When this occurs, you should left click the mouse to start the stream if that is the position
you desire.
When completing the stream, the cursor will remain as a black arrow. When the cursor is near a proper
inlet or outlet position, the UnitOp inlet and outlet points will appear and a label will appear. Obviously, if
a stream was started at an inlet point, it must be connected to an outlet point.
Once the desired position has been located (as indicated by the appearance of the label), you should left
click the mouse to complete the stream.
While drawing a stream, the palette will disappear. It will reappear only when you left click somewhere
on the flowsheet, which is not a UnitOp inlet or outlet point. You are not required to click the stream
(link) icon square each time you begin a stream.
140
CHEMCAD Version 5.4 User’s Guide
You can alternate between placing UnitOps on the screen and connecting them with streams as long as
the above rules are followed.
The first time you change directions of a stream; CHEMCAD will let you do so without any problem.
Every additional time you change directions, you must first press the left button on the mouse to identify
the longitude or latitude through which you want the stream to pass. Doing this will create an anchor
point to fix the longitude or latitude on the screen.
To draw streams that change direction more than once, use the following procedure.
Click the Streams icon box on the palette. The palette will disappear and the crosshairs cursor will
appear.
Move the cursor close to either an inlet point or an outlet point on a unit operation icon. When the cursor
switches to a black arrow, press the left button on the mouse.
Draw the stream as you normally would, but before you make your second turn, move the cursor to the
longitude or latitude at which you wish to force the stream to pass through. Then click the left button on
the mouse. A small circle will appear indicating the position of the anchor point.
Repeat step 3 for each additional change in direction.
When desired, move the cursor close to the desired destination inlet or outlet point. When the label
appears, left click the mouse. The stream will then be complete.
In order to select components for the component list, you must first call the Component Selection
dialog box, and then use that dialog box to select the components from those stored in any of the
141
User’s Guide CHEMCAD Version 5.4
available CHEMCAD physical properties databanks. To call the Component Selection dialog box, you
must select it from the ThermoPhysical menu or click on the Define Components button on the tool
bar.
b. Select the Component List option from the menu. This can be done in two ways:
• Point and click Component List with the mouse, or
• Press the [L] key (Note: press [L] not [ALT + L].)
From the Tool Bar:
142
CHEMCAD Version 5.4 User’s Guide
BRIEFLY
To select components from the component databank list in the right-hand window of the dialog box you
should:
1. Locate the desired component by scrolling through the list. You can scroll by using:
• the elevator bar
• the arrow keys
• the [PgUp] and [PgDn] keys
• the Search field in the lower center of the dialog box
2. Select the component by:
• highlighting it and clicking the Add button
• highlighting it and hitting the [Enter] key
• double clicking on the component
DETAILS
There are six (6) functional parts to this dialog box. These are:
1. The Selected Components area in the upper left portion of the dialog box. This area will display
the components that have already been selected (if any). This area is normally dormant, but it can
be activated by clicking anywhere on it. When active, a highlight will appear over one of the
components. The Selected Components area is activated only when you want to insert or delete
components.
2. The Component Databank area is in the upper right hand portion of the dialog box. This displays a
list of all the components in any of the databases, which are currently accessible to CHEMCAD.
The actual component selections are made from here either by double clicking on the component
desired or by highlighting it and pressing the Add button.
143
User’s Guide CHEMCAD Version 5.4
The highlight can be moved by single clicking the mouse on the desired component; by using the
elevator bar; by using the arrow, [PgUp], or [PgDn] keys; or by typing in an identifying string in the
Search Component field described below.
Components with ID numbers between 1 and 5,000 are from the CHEMCAD Suite database.
Components 6,001 – 8,000 are from the corporate pool database. Components from 8,001 – 9,999
are from the local user database. Components 5,001 – 6,000 are for pseudo-components.
3. The Search Component option is in the lower right portion of the dialog box. Typing in this field
causes the program to scroll through the Component Databank list to find the alphanumeric string
you typed. Some strings are embedded in more than one component (e.g., "ethanol" is in methanol
and ethanol, as well as others). If the first component that the program finds is not the one you
want, you can then press the Next button to try the next component found. Continue until you find
the correct component.
4. The Add (Add new components) button is in the lower left-hand portion of the dialog box. This
option allows the user to add components to the bottom of the current job component list. You can
invoke this option by highlighting the desired component, then clicking the Add button with the
mouse or by pressing the alternate [A] key. Of course, an alternate way to add components to the
component list is to double click on the desired component.
5. The Insert button is in the lower left-hand portion of the dialog box just above the Search
Component field. This option allows the user to insert components from the database anywhere in
the current component list. To use this option, follow the procedure given below.
• Identify the position in the component list where you want the new component inserted. Do this
by highlighting the component which currently occupies that position.
• Select the new component from the Component Databank list.
• Click the Insert button. The new component will appear, highlighted, in the component list. All
components below the inserted component will move down one position.
6. The Delete button is in the lower left-hand portion of the dialog box. This option allows the user to
delete components from the component list. To use this option, follow the procedures given below:
• Highlight the component to be deleted.
• Click the Delete button or press the [Alt + D] key.
7. The Clear button simply deletes all of the components in the list at once.
When finished making selections, press the [OK] button to save your work or [Cancel] to cancel your
changes.
To make K-value model selections, you must call the K-value Options dialog box.
144
CHEMCAD Version 5.4 User’s Guide
BRIEFLY
K-Value button
2. The K-value Options dialog box will appear.
3. Open the Global K-value Option list in the upper left by clicking on the field.
4. Scroll this list until the desired K-value model is displayed.
5. Select the desired model by clicking it with the mouse.
6. Make any supplementary selections (presented in the rest of the dialog box).
7. Close the K-value Options dialog box by clicking [OK].
8. You will be asked if you want to reinitialize all of the streams. If you are unsure, click [YES].
DETAILS
145
User’s Guide CHEMCAD Version 5.4
Global K-value Options: This field provides a list of all the K-values models offered in the
CHEMCAD Suite. A selection from this list becomes the basic, global (i.e., applied to all UnitOps in
the simulation) K-value model for the active flowsheet. Certain options within the basic selection
can be invoked using the fields described below.
Procedure:
• To open the K-value models list, click on it with the mouse.
• The list is scrollable using the elevator bar, the [PgUp] and [PgDn] keys, and the arrow keys.
Scroll the list until the desired model is displayed.
• Select the desired model by clicking it with mouse, or by highlighting it, then pressing the
[ENTER] or [TAB] keys.
The following K-value dialog box options are choice boxes. Click the appropriate selection. (For a
description of how to use choice boxes in CHEMCAD, please refer to Using dialog boxes/Making
choice box selections.)
Ethane/Ethylene, Propane/Propylene
Allows you to select whether you want to use standard BIPs or specially fitted BIPs for the
ethane/ethylene and propane/propylene pairs when using the SRK or Peng-Robinson equations of
state. Typically, the special BIPs will give the best results near the critical points.
Vapor Phase Association
Certain compounds, especially carboxylic acids, have the tendency to dimerize or even polymerize
in the vapor phase. You can ask CHEMCAD to take this effect into account by activating this option.
Vapor Fugacity/Poynting Correction
When using a liquid activity coefficient K-Value method, you may treat the vapor phase as an ideal
solution or as a regular solution. The latter requires use of the vapor fugacity Poynting correction.
In the default condition, CHEMCAD assumes the vapor phase is an ideal solution. This is the No
Correction option. If you want the Poynting correction included in the calculation, you must select
the Correction option. In such cases, the vapor fugacity will be calculated using the SRK equation
of state. Typically, it is safe to ignore this correction at lower operating pressures.
Alpha Function
For SRK and Peng-Robinson EOS models, you are allowed to choose either the standard alpha
function or the newer Boston-Mathias alpha function. The default is the standard alpha function.
To make enthalpy model selections, you must call the Enthalpy Options dialog box.
BRIEFLY
1. Click the Enthalpy button on the toolbar.
Enthalpy button
146
CHEMCAD Version 5.4 User’s Guide
3. Open the Global Enthalpy Option: field in the upper left by clicking on it. It should open up a list.
4. Select the desired model by clicking it with the mouse.
5. Make any supplementary selections (presented in the rest of the dialog box).
6. Close the Enthalpy Options dialog box by clicking [OK].
7. Upon exiting this dialog box, you will be asked if you want to reinitialize all of the streams (if any
exist). If you are unsure about this, click [YES].
DETAILS
1. The Enthalpy Option dialog box is called:
From the toolbar by clicking on the Enthalpy button, or
From the main menu bar select the ThermoPhysical command by:
- Clicking it with the mouse, or
- Pressing the [ALT + L] keys.
The ThermoPhysical menu will appear.
From the ThermoPhysical menu, select the Enthalpy option by clicking it with the mouse, or by
pressing the [E] key.
The Enthalpy Options dialog box will appear.
2. The Enthalpy Options dialog box options.
Procedure:
• To open the Global Enthalpy Options list, click on it with the mouse.
• Select the desired model by clicking it with mouse, or highlighting it, then pressing the [ENTER]
or [TAB] keys.
147
User’s Guide CHEMCAD Version 5.4
Global Enthalpy Options: The Global Enthalpy option is a combo box. This field provides a list
of all the enthalpy models offered in CHEMCAD. A selection from this list becomes the basic, global
(i.e., applied to all UnitOps in the simulation) enthalpy model for the active flowsheet. Certain
options within the basic selection can be invoked using the fields described below.
Click the appropriate selection. (For a description of how to use combo boxes in CHEMCAD, please
refer to Using dialog boxes).
Ideal Gas Heat Capacity:
Choose between two equation forms (Polynomial or DIPPR) for calculation of ideal gas heat
capacity. A description of these forms is given in the on-line manual.
The remaining entries in Enthalpy Options dialog box are optional.
Use Heat of Solution File?
If you have a file that contains heats of solution data, then you must click on this field to inform the
program to look for the file with the HTS extension.
Use electrolyte enthalpy:
The electrolytes model contains an enthalpy model to compensate for heat of dissociation. This
check box allows the user to turn off enthalpy effects of dissociation if an electrolytes model is in
use. This setting has no effect on non-electrolytes models.
Clear all Local H Model?
A checkmark in this field will reset all local enthalpy models back to the global setting.
Specify Local H Model?
Allows you to select different enthalpy models for different unit operations in the flowsheet. A
checkmark in this field will allow you to pick individual equipment on the flowsheet and set specific
enthalpy models for each one.
Heat of Mixing by Gamma?
This option includes the heat of mixing in the heat balance. The heat of mixing is computed from
activity coefficient.
Compressed water pressure correction for steam table at very high pressure the enthalpy of
water requires some correction to the normal IFC equation which is normally used to calculate water
enthalpies. Under these conditions, this correction can cause a significant difference in the enthalpy
of a water stream.
BRIEFLY…
1. Double-click on the desired stream (not the stream number 10 box). The Edit Streams dialog box
will appear.
148
CHEMCAD Version 5.4 User’s Guide
149
User’s Guide CHEMCAD Version 5.4
that accounts for the solubility of water in the hydrocarbons. For all other methods, water is
considered to be miscible.
Salt Position for Wilson Model
Enter the position in the component list of the compound designated as the salt if using the Wilson
Salt Effect K-value option.
No. of BIP Sets
CHEMCAD allows you to have up to ten (10) sets of BIPs for each activity coefficient method. This
gives you the flexibility of using one set of BIPs in one section of a flowsheet and a different set in
another. A typical use of this would be when you know that two liquid phases exist in the condenser
of a distillation column. You can choose to use NRTL LLE BIPs in the condenser and NRTL VLE for
the rest of the column.
Default BIP Set
Defines the set to be used globally by the program.
Clear Local K Model?
Click on this field if you wish to reset ALL local K-value models back to the global K-value model.
Set Local K/BIP Model?
If you click on this field, the program will then go into an equipment selection mode when you close
the K-value Options dialog box. The user can then define what K-value model or BIP set is
applicable to the particular unit operation.
Set Tray BIP?
If the user clicks on this field, upon exiting the K-value dialog box, the program will go into selection
mode and allow you to choose one or more distillation towers from the flowsheet. It will then
present you with an input screen where you can enter a range of tray numbers and the BIP set that
applies to that range.
Set Henry’s Components
When using an activity coefficient model, the K-value for super critical components is calculated
using the SRK EOS (default) or the Henry’s Gas Law equation. Selecting this option allows the user
to identify which super critical components are to be handled by the Henry’s equation instead of by
SRK.
If this option is selected, a special dialog box will appear upon exiting the K-value Options.
• Select the Specifications on the menu bar command by:
- Clicking on it, or
- Pressing [ALT + S] on the keyboard.
The Specifications menu will appear.
• From the Specifications menu select either the Feed streams or the Select streams option
by clicking or by pressing the underlined letter.
Selecting the Feed streams option will immediately call the Edit Streams dialog box for every
feed stream on the flowsheet.
150
CHEMCAD Version 5.4 User’s Guide
Selecting the Select streams option will cause the Select Streams dialog box to appear. This
dialog box is used to identify the feed streams. This can be done either by using the mouse to
click on the desired streams, or by typing the stream ID numbers (separated by spaces) of the
flowsheet feed streams. If you use the mouse, the stream number will appear in the dialog box
field as you click each stream. When all the required streams have been selected, click the
[OK] button in the dialog box. The Edit Streams dialog box will appear.
2. Complete the dialog box:
Note the following points about this dialog box.
• The first field, called Stream Name allows you to enter a stream label or name.
Note: Entering and/or editing such stream labels can also be done a number of other
ways.
• The next four fields; temperature, pressure, vapor fraction, and enthalpy are the thermodynamic
properties of the stream. According to the Gibbs phase rule, once the composition is given,
specifying any two of the four thermodynamic properties of a mixture will define the other two.
Thus, defining the composition, temperature, and pressure uniquely defines the vapor fraction
and enthalpy (again, this is for a mixture only). Alternately, defining the composition, pressure,
and enthalpy will uniquely define temperature and vapor fraction.
CHEMCAD, however, by convention, does not permit this much freedom. Since
enthalpies are calculated relative to a datum, the calculation of any given stream
enthalpy is an involved process which is prone to errors. For this reason, CHEMCAD
does not permit you to enter stream enthalpy. (There is one exception to this rule;
when the total component flowrate of a stream is zero, entering an enthalpy in a
stream may serve as an alternative way of adding a heat duty to a unit.)
Therefore, to uniquely define any stream in the CHEMCAD Suite, the user must define
the composition of that stream, and any two of temperature, pressure, and vapor
fraction. This is for a mixture. For pure components, all three thermodynamic
properties are sometimes required.
• The fields Total Flowrate Units and Component Flow Units work together to provide
the user with a variety of ways to define stream compositions. If the Component Flow
Units are set to mole, mass, or volume fraction (which can be done globally or locally)
then the Total Flowrate Units menu will become available.
If Component Flow Units is set as a flow or amount option, then the total flowrate
becomes the sum of the component flowrates and the Total Flowrate Units menu will
“gray out” and therefore be unavailable for editing. In this situation, as the component
flowrate values are entered, they are automatically summed and the current sum is
displayed in the field labeled Total Flowrate.
• In the top left of the dialog box is the [Flash] button. Clicking this button at anytime
will cause the program to perform a flash calculation using the currently specified
composition and thermodynamic properties. This allows quick flash calculations to be
made without exiting the dialog box.
151
User’s Guide CHEMCAD Version 5.4
• Fractions that do not sum to 1.0 are automatically normalized upon flashing or exiting
the dialog box.
3. Click the [OK] button. This will close the dialog box and simultaneously save the data. CHEMCAD
will automatically perform a flash calculation on the stream before saving the data.
For each UnitOp in the CHEMCAD library, there is a corresponding, unique dialog box for specifying its
operation. These dialog boxes are the means by which:
1. The user provides the specifications necessary to match the degrees of freedom present in the
flowsheet. This step is necessary for a unique solution to exist.
2. Certain options, which are not essential to a unique solution, are exercised.
Therefore, before running a simulation, it is necessary that the relevant UnitOp dialog boxes be
completed properly.
For a description of each item of each UnitOp dialog box, please refer to the Help system.
CALLING A UNITOP DIALOG BOX
The rules for using UnitOp dialog boxes are described in the section “Using Dialog Boxes” of this
manual.
DEGREES OF FREEDOM AND UNITOP DIALOG BOXES
Generally speaking, each time a unit operation is added to the flowsheet, it adds one or more degrees of
freedom to the simulation. The number of degrees of freedom created depends upon the UnitOp itself.
Most UnitOps will create one, but many will add more. For each degree of freedom created, one
specification must be made for a unique solution to exist*.
152
CHEMCAD Version 5.4 User’s Guide
Since CHEMCAD is a modular sequential simulator, the specification must be made at the UnitOp that
created the degree-of-freedom. For example, a two-outlet distillation column with a condenser and
reboiler creates two degrees of freedom when added to the flowsheet. Therefore, two specifications
must be made in the column dialog box.
If the user provides either too many or too few specifications, CHEMCAD will issue an error message to
that effect when exiting the dialog box. Errors such as these must be corrected before the simulation
can be run.
As a guideline dialog boxes in the CHEMCAD Suite show critical data for UnitOps in green.
* These specifications must be other than pressure. Equilibrium based simulators such as
CHEMCAD assume the pressure is always known. Exceptions can and are made but these are
not the rule and must be uniquely handled.
There are four “categories” of simulation runs in the CHEMCAD Suite. These are steady state
simulation, optimization, sensitivity analysis, and dynamics simulation. All four are run from the Run
command on the menu bar.
• CC-STEADY STATE, CC-SAFETY NET, CC-THERM, CC-FLASH and CC-BATCH simulations
are run using the steady state run commands.
• CC-DYNAMICS (CC-ReACS and CC-DCOLUMN) simulations are run using the dynamics run
menu.
• Optimization will minimize or maximize an objective function.
• Sensitivity analysis will run parametric studies.
RUNNING STEADY STATE SIMULATIONS
To run the simulation, point and click on the Run command on the top-level menu or press the [ALT + R]
keys. This will cause the Run menu to open. This menu has the following options:
• Convergence
• Run All
• Run selected Units
• Recycles
• Calc sequence
• Optimization
• Sensitivity
• Dynamics
153
User’s Guide CHEMCAD Version 5.4
The commands Optimization, Sensitivity, and Dynamics are described elsewhere. The remaining
commands Run All, Run selected Units, Recycles, and Calculating Sequence are concerned with
steady state simulation and are described below.
Run All This option will run the entire flowsheet.
Run Select UnitOps This option will permit you to specify which units are to be run. The units are
simulated in the order specified by the user.
Recycle This option permits the user to identify the calculation order of recycle
flowsheets.
Calc Sequence This option allows the user to specify his/her own calculation sequences.
Whenever you click one of the “run” commands, the following sequence of events is executed:
1. The program will immediately check the data and list any errors and/or warnings on the screen in a
message box. Errors are fatal and therefore indicate conditions which must be corrected before the
calculation can start. Failure to completely specify a unit operation is an example of an error.
Warning messages are not fatal and indicate conditions of which the user should be aware, but
which will not keep the simulation from proceeding. Failure to specify cut stream initial estimates is
an example of a condition, which will generate a warning message.
2. If the Display trace window option has not been activated, the program will proceed straight to the
calculations and when finished will display convergence or completion messages in a message
window or on the bottom line of the main CHEMCAD window.
If the Display trace window option has been activated on the Convergence dialog box, the
CHEMCAD Trace Window will open next. The CHEMCAD Trace Window, despite its name, is a
dialog box, not a window. Its’ purpose is two fold
• To display runtime messages
154
CHEMCAD Version 5.4 User’s Guide
You will notice that there are three buttons at the bottom of this dialog box. These are:
• The Go button starts and restarts the simulation calculations.
• The Stop button stops or pauses the simulation. Clicking this button will suspend the
simulation calculations. Once stopped, the simulation may be restarted by clicking the Go
button, or terminated by clicking the Close button. Whenever a simulation is restarted, it picks
up where it left off. It does not begin all over again.
• The Close button terminates the calculation (if it is in progress) and closes the CHEMCAD
Trace Window.
During the simulation, as the program moves from one unit to the next, messages will be displayed in the
CHEMCAD Trace Window. While the simulation is in progress, a steady stream of messages will
appear in this "window".
When the simulation is finished, the message "Run finished" will appear on the bottom line of the
CHEMCAD Trace Window dialog box. The dialog box will not close automatically, but will remain open
so that you can scroll and browse the runtime messages. After browsing, if you want to proceed, you
must click the Close button.
The overall procedure for viewing stream compositions (on the screen) is:
1. Select the Results command on the menu bar. The Results menu will appear.
2. Set the flow rate engineering units to be used to display the compositions. Clicking the Set Flow
Units option on the Results menu does this. The View Flow Rate Unit dialog box will appear.
This dialog box will display a list of options. Only one of these can be active at a time. The active
option will have a dot in the circle next to it. To change it, click on the circle for the desired option,
then close the dialog box.
3. Reopen the Results menu and highlight the Stream Compositions option. The Stream
Compositions menu will open.
4. Select one of the five options on the Stream Compositions menu. Each option is a unique way to
select the streams to be displayed, and each is executed a little differently. Details are provided
below under “Selecting Streams”.
5. Once the streams have been selected, their compositions will be displayed in a Wordpad window.
In this window, the results may be scrolled, printed, edited, or filed using Wordpad commands.
When ready close the Wordpad window by clicking the Close button.
SELECTING STREAMS
As item 4 above mentions, there are five options for selecting streams in the Results command:
• Select Streams
• All Streams
155
User’s Guide CHEMCAD Version 5.4
• Feed Streams
• Product Streams
• UnitOp Streams
These options operate as described below.
1. Select Streams
Choosing this command invokes the Select Stream(s) dialog box. This dialog box contains a blank
field where the stream ID numbers are to be entered either by typing or by clicking the streams on
the flowsheet. Once the desired streams have been selected, the dialog box is closed.
2. All Streams
Selecting this option immediately displays the compositions of all the streams on the flowsheet.
These are displayed in a Wordpad window.
3. Feed Streams
This option automatically displays the compositions of all the feed streams of the flowsheet. These
are displayed a Wordpad window.
4. Product Streams
This option automatically displays the compositions of all the product streams on the flowsheet.
These are displayed in a Wordpad window.
5. Unit Streams
This option displays the compositions of all the inlet and outlet streams of a certain UnitOp. The
user must identify which UnitOp. When the Unit Streams option is selected, the Select UnitOp
dialog box appears. This dialog box contains a blank field where the UnitOp ID numbers are to be
entered either by typing or by clicking the UnitOps on the flowsheet. Once the desired UnitOps
have been selected, the dialog box is closed.
Clicking on the desired UnitOp with this cursor will cause the associated stream compositions to be
displayed in a Wordpad window.
It is possible to view steam compositions and include stream compositions in reports using flowrate
units, which are different from those set for the simulation. The procedure for this is:
1. Select Results from the main menu bar.
2. The first item on the menu will be Set Flow Units. Select this command. The View Flow Rate Unit
dialog box will open.
3. Find the desired units on the list displayed.
4. Select the option by clicking on it or its radio button, then press [OK].
156
CHEMCAD Version 5.4 User’s Guide
The overall procedure for viewing stream properties (on the screen) is:
1. Select the Results command on the main menu bar. The Results menu will appear.
2. Highlight the Stream Properties option of the Results menu. The Stream Properties menu will
open.
3. Select the Select Properties option from the Stream Properties menu. The View Property
Options dialog box will appear.
4. Select the desired properties and close the dialog box (see "Using the View Property Options
dialog box"). You will be returned to the main window.
5. Return to the Stream Properties menu and choose one of the five available options for choosing
streams. Each option is a unique way to select the streams to be displayed, and each is executed a
little differently. Details are provided above under "Selecting Streams".
6. Once the streams have been selected, their properties will be displayed as a report in a Wordpad
document. In this window, the results may be viewed, edited, printed, or filed. Operation of this
window is described elsewhere.
7. When ready, clicking the [Close] button closes the Wordpad document, and you are returned to the
CHEMCAD main window.
USING THE PROPERTIES OPTION DIALOG BOX
Selecting the Stream Properties options calls the View Property Options dialog box.
This dialog box offers two pages of property options. Default options are already checked. Turn on and
off the check mark in the box next to each option. This can be done by:
1. Moving the focus to the desired option then pressing the [SPACE BAR]. The focus is a dashed box
around the option label. It may be moved by the [TAB] key or the [ENTER] key.
2. Clicking the option with the cursor.
Once all selections have been made, click [OK].
COMPOSITION OPTION:
The Composition Option prints stream composition with the stream properties. This is in addition to
the stream property output selected above. You may choose the flow units to be used in this printout by
opening the combo box and selecting an appropriate option.
HOW TO PLOT
CHEMCAD allows you to create a wide range of plots. These plots are initially displayed on the screen
where they can be reviewed and edited before a hardcopy is printed. There are sixteen (16) plot dialog
boxes. Each is specific to the type of plot being generated, and each offers options defining exactly what
and how information is to be displayed.
157
User’s Guide CHEMCAD Version 5.4
Procedure:
1. Select the Plot command from the main menu bar. The Plot menu will appear. The Plot menu
offers the sixteen categories of plots mentioned above. These are described below under "Plot
Menu Options".
2. Select the appropriate option by clicking it, pressing the underscored letter key, or by moving the
highlight (with the [UP] or [DOWN] arrow keys) and pressing [ENTER].
3. Where applicable, you will be asked by a dialog box to identify the stream(s) or UnitOp(s) pertinent
to this plot by clicking it or typing its ID number. When this is finished, click [OK]. The selected
dialog box will appear.
4. Complete the dialog box as required. When finished, click [OK]. The plot will appear inside a new
window. In some cases, a Wordpad document with tabular data used for the plot will appear first.
You can browse this data if necessary, or you can simple close the window to see the plot window.
This window is similar to other graphics windows in CHEMCAD, and has the following commands
available:
File For printing, windows control and various bar selections
Edit For cutting and pasting, etc
View For turning on and off toolbars and status bars
Graph For editing graph style and information
Window For arranging windows, etc
Help For accessing CHEMCAD help
5. Modify the plot as desired, and generate any necessary hard copies. For more specific instructions
on how to use the graphics commands included in the plot edit window, see also:
• "How to Use the Chart Explorer".
A hardcopy of the plot can be obtained by pressing [CTRL + P], clicking the Print button, or by
going through the File command on the menu bar. (See “How to Print”.)
6. When finished, close the Plot window by clicking the Close button. For certain plots, a new window
will appear containing a tabulation of the numerical values used to create the plot. These results
may be browsed and printed, but not modified. Close this window by clicking the Close button. You
will be returned to the Simulate Flowsheet Window.
PLOT MENU OPTIONS
From this menu, you can plot data ranging from stream properties to tower composition profiles and from
vapor liquid equilibrium diagrams to heat exchanger heat curves.
158
CHEMCAD Version 5.4 User’s Guide
Command Function
Tower Profiles Plots compositions, temperature, and flow profiles for distillation
modules in either an XY or bar chart format.
TPXY Temperature, pressure, and composition equilibrium plot. It will
optionally plot experimental data points.
Residue Curve Map Generates and plots a residue curve map. A residue curve map is
a graphical display of distillation zones, azeotropes, and residue
curves associated with a user specified ternary (3 component liquid
mixture).
Binodal Plot Generates a triangular plot useful for visualizing equilibrium of
ternary systems.
Envelopes Plots a phase envelope for a given stream. Highlights the critical
point of the mixture and can include plots at vapor fractions other
than zero (bubble point curve) and one (dew point curve).
Heat Curves Plots heating or cooling curves for heat exchangers.
Composite Curves Plots composite heat curves for the flowsheet.
Properties Allows you to generate plots of properties for a given stream.
Distillation Curves Displays a plot of one or more distillation curves for a stream.
Plug Flow Reactor Profile Plots the temperature or composition profiles along the axial length
of a kinetic plug flow reactor.
Controller Convergence Plots the convergence error of a controller as a function of the
iteration number.
Batch Reactor/DVSL Plots the histories of a batch reactor or a dynamic vessel history.
History
Batch Column History Plots Batch Column value history.
Dynamic Column History Plots Dynamic Column value history.
Dynamic Stream History Plots dynamic stream value history.
159
User’s Guide CHEMCAD Version 5.4
1. Tower Profiles
This command plots profiles for distillation columns. The column may be either a batch distillation
column or one of the rigorous steady state models. The main difference between the two is that
when you select a batch column the program will ask you to specify which operating step (the end
of) is to be plotted. The steady state models will not ask this question. In either case, the user is
presented with the Profile Options dialog box.
• Temperature Profile
Clicking on this box will generate a plot of temperature versus stage number.
• Total Flow
Total Vapor Flow? Total Liquid Flow?
Click next to either one (or both) of these boxes will cause the item to be included in the plot.
• Phase Option
Decide which phase you wish to access when you ask for a composition versus stage number
plot. Click on the field to open the pull down list. The last two options only apply when there
are two liquid phases present. Options are:
- Liquid Phase
- Vapor Phase
- Light Liquid Phase
160
CHEMCAD Version 5.4 User’s Guide
161
User’s Guide CHEMCAD Version 5.4
• Enter Component
Select the components to be plotted using the list provided.
• Mode
TPXY plots are at fixed temperature or fixed pressure. You must indicate which. Fixed
pressure is the default.
• Spec.
Enter either the temperature or pressure, depending on what was selected in the Mode field
above. Default = 1 atm.
• Estimation
In extreme cases, it is necessary to enter an initial estimate for the specification. This option is
normally left blank.
• No. of Points
Enter the number of points to plot. Default = 20.
• X mol frac. from/to
Enter the range to plot for the liquid mole fraction. You may choose any range desired,
provided both values are fractions between zero and 1.0.
• Plot experimental data
A Yes in this field superimposes experimental data points over the plot of the calculated values.
• For a constant amount of a third component
These fields are used to define parameters for the “third” component in a ternary mixture.
- Third component – Select the component to be the third component in the ternary
system.
- Mole Frac – Specify the mole fraction for the third component (x3). The TPXY plot will be
generated at this fixed x3 value.
- Show XY as actual composition– This is the default option. Check this option if you wish
to have CHEMCAD show the XY plot with the specified composition for the third
component.
- Show XY excluding 3rd component– This option allows you to have CHEMCAD show
the XY plot excluding the third component without having to delete your previous optional
specifications. Check this option if you wish to have CHEMCAD show the XY plot for the
first two components leaving your third component specifications intact.
• Axis Mode
TPXY plots may be in mole fractions [Default] or mass fractions.
3. Residue Curve Map
Generates a triangular plot for ternary distillation calculations.
162
CHEMCAD Version 5.4 User’s Guide
163
User’s Guide CHEMCAD Version 5.4
•
st nd rd
1 , 2 , 3 Component
Select the three components to be included in the plot by using the combo boxes provided.
• Temperature
Enter the temperature for which the plot is to be created.
• Step Length
Indicates the step length used in binodal curve construction. Step length is entered in units of
mole fraction. [Default = 0.05]
• Y1, Y3
It is only possible to generate a binodal plot if the first and the third components are insoluble in
each other. Y1 and Y3 are estimates of the mole fractions at which this occurs. Typically, it is
not necessary to enter these numbers. However, it may be necessary to enter values if a
message stating “the program did not converge” is received.
• Plot experimental data
Click here to superimpose experimental data points over the plot of the calculated values.
• Flow Units
The binodal plot may be displayed in mole percent or weight percent.
5. Envelope
Generates a plot of the phase envelope for any stream in the flowsheet. To use this option, there
must be a stream of known composition in the flowsheet.
The program will ask you to select the stream to be plotted. It will then display the Phase Envelope
Options dialog box.
164
CHEMCAD Version 5.4 User’s Guide
• Estimations (optional)
Initial estimates for the starting bubble point and dew point temperatures, may be entered.
Typically, this is only necessary when the program is having difficulty converging.
• Vapor Fractions (optional)
To construct the phase envelope, CHEMCAD calculates bubble point and dew point
temperatures while incrementing the pressure. Once it reaches the critical point, it displays the
plot. You may force the calculation of envelopes at four additional states of vaporization. Enter
the vapor fractions for the intermediate lines.
• Starting Pressure
Defines the starting pressure for the phase envelope (optional).
6. Heat Curves
Plots heat release curves for either stand-alone heat exchangers or for reboilers and condensers of
distillation columns. When you first select this command, the program will prompt for selection of a
heat exchanger or column. A dialog box will appear where you may set the following options.
• No. of Points
Specifies how many points will be included in the heat curve calculation. [Default = 11]
• Zone Cut Option
Indicates whether the zones are to be based on equal temperature, equal enthalpy increments,
or equal enthalpy between the dew and bubble points. [Default = Temp]
• Plot Option
Select one of the following,
Plot X-axis – DelH, Y-axis = Temp – The x-axis will be change in enthalpy and the y-axis will
be temperature.
Plot X-axis = % length, Y-axis = Temp – The x-axis will be percent of tube length and the y-
axis will be temperature.
165
User’s Guide CHEMCAD Version 5.4
7. Composite Curves
By selecting a group of heat exchangers, you can generate composite heat curves, combining their
heat release curves. This allows you to examine the system for potential pinch zones. CC-
STEADY STATE first allows you to select up to fifty (50) exchangers to include in the analysis. You
are only allowed to select HTXR’s and LNGH’s. You select the equipment either by clicking it with
the mouse or by entering their ID numbers in the fields provided on the Composite Heat Curve
screen.
166
CHEMCAD Version 5.4 User’s Guide
8. Properties
With this command you can obtain plots of ten properties for any stream in the flowsheet. The
stream must be fully defined. Selection is made using the Select Streams dialog box. After you
select the stream, you get the Properties Options dialog box.
167
User’s Guide CHEMCAD Version 5.4
The program will then ask you to select the streams to plot.
10. Plug Flow Reactor Profile
This plot option is only available for kinetic reactors (KREA), which have been specified as PFR
(Plug Flow) reactors.
- Plot frequency
Specify the number of points to be plotted per number of points recorded. Normally one point is
recorded per time step.
- Composition options
Select the desired composition option for the plot. Options are:
Mole fractions Moles
Mass fractions Mass
Volume fractions Volume
168
CHEMCAD Version 5.4 User’s Guide
- Temperature
Click here if you want the temperature profile to be plotted.
- Select components to be plotted
Select the components to be plotted and enter the scale (factor) by which that component value is to
be multiplied before it is plotted. Leaving the scale field blank sets the scale equal to one.
11. Controller convergence
This option plots controller convergence errors as a function of controller iteration number. There is
no dialog box for this plot option other than the one asking the user to identify the relevant controller
(if necessary). The controller must have already been run and an iteration history file exist for the
program to plot this option.
12. Batch Reactor/DVSC History
Batch Reactor History
- Time Unit – Use the combo box to choose from hours, minutes, or seconds for the x-
axis units.
- Plot frequency - The number of points plotted per points recorded.
- Composition Options – Open this combo box by clicking it. Choose the desired
value for the y-axis. Options are listed:
% mole fraction moles
% mass fraction mass
% liquid volume fraction liquid volume
moles/volume rate of formation
% conversion % selectivity
rate ratio
169
User’s Guide CHEMCAD Version 5.4
170
CHEMCAD Version 5.4 User’s Guide
Vessel pressure
Liquid level 1 (light)
Liquid volume 1 (light)
Liquid level 2 (heavy)
Liquid volume 2 (heavy)
Vapor volume
Heat duty
Utility temperature out
13. Batch Column History
• Operation Step
Select the operation step for which to make the plot. Enter the number of the individual step
you wish to examine. If this field is empty, the program will plot a history for ALL the steps.
• Variable to be plotted
Define the variable to be plotted on the y-axis. Select one from the pull-down list:
Mole Fraction Reflux Ratio
Mass Fraction Reboiler Duty
Volume Fraction Condenser Duty
Mole Flow Temperature
Mass Flow Volume Flow
Pressure Reflux mole rate
Reflux mass rate
• Object to be plotted
Select one of the following. This field may not be needed if the variable specified above does
not require a location (e.g., Reflux Ratio).
171
User’s Guide CHEMCAD Version 5.4
Accumulator Decanter
Bottom Decanter Distillate
Distillate Stage
• For plots of stages
If a plot for one of the stages in the column is desired, specify the following:
- Stage No. – Enter the stage number for which the properties will be plotted.
- Phase – Indicate whether you are plotting data for the liquid or vapor phase.
• X-variable
Decide whether you want time [Default] or fraction distilled as the item plotted on the X-axis.
• Component plotted
Select the component(s) to be plotted.
14. Dynamic Column History
After running a Dynamic Column, you may plot several of the recorded values using this option.
Once you click this option, you are asked to select the dynamic column on your flowsheet. Once
you click [OK], you will see the following dialog box:
• Variable to be plotted
Define the variable to be plotted on the y-axis. Select one from the pull-down list.
• Object to be plotted
Select one of the following. This field may not be needed if the variable specified above does
not require a location (e.g., Reflux Ratio).
Distillate
Bottom
Stage
• For plots of stages
If a plot for one of the stages in the column is desired, specify the following:
172
CHEMCAD Version 5.4 User’s Guide
- Stage No. – Enter the stage number for which the properties will be plotted.
- Phase – Indicate whether you are plotting data for the liquid or vapor phase.
• Time Unit / Frequency
Specify what time unit you want to use for the x-axis and the frequency you want plotted.
• Y-axis Min/Max
Specify a minimum and maximum for the y-axis of your plot
• Component plotted
Select the component(s) to be plotted.
15. Dynamic Stream History
After running a dynamic flowsheet, you can plot stream data versus time, if you have specified that a
stream be recorded in the Dynamics Menu. Selecting this option will open the following dialog box:
The General Tab
• Stream number
Define the stream number to be plotted. If a stream is currently selected, its value will
automatically appear in this field. You must have specified that this stream be recorded.
• Plot Frequency/Time Unit
Specify the frequency and time for the stream variables to be plotted.
• Composition / Components
Specify whether or not you desire a composition/time plot and the units you desire (i.e.
mole/mass/mass frac/ etc). Also specify which components are to be plotted.
173
User’s Guide CHEMCAD Version 5.4
Specify which stream variables or properties are to be plotted by using the check boxes next to the
variable names.
16. Dynamic UnitOp History
After running a dynamic flowsheet, you can plot unit operation data versus time, if you have
specified that a unit operation be recorded in the Dynamics menu. When you select this option,
you will see the following dialog box:
174
CHEMCAD Version 5.4 User’s Guide
• Variable
Select the variable that you would like to plot from the drop down menu or using the check
boxes next the variable names. You will see a list of all available variables (differs for each type
of unit).
• Title Specifications (optional)
Specify a plot title and y-axis title if you desire.
17. Stream Recorder
Plots recorded data as a function of iterations (which may represent time). This function is
especially useful in tracking recycle variables when dealing with a convergence problem.
18. User Specified File
Plots a user-designated file. The file must be in a certain file format as explained in the following
message box, which appears when you select this option:
Clicking [OK] displays a dialog box for identifying the location of the file to be plotted.
175
User’s Guide CHEMCAD Version 5.4
CHEMCAD will create a formalized, professional quality report. This report is in a more or less
standardized format. Formatting options are available and you have extensive control over contents.
To produce a report, use the Output option on the main menu bar. Click Output or press the [ALT + O].
The Output menu will appear, and you will have the following options:
Job Note Enables the user to keep a running set of notes regarding the
flowsheet, the process, and their development. The notes are
kept in a WordPad file associated with the job.
Reports For generating tabular hardcopy outputs.
Main PFD For producing and editing the primary (first) process flow
diagram.
New PFD For producing additional process flow diagrams.
Open PFD Opens a previously created PFD.
To generate a report, select the Report option. The following menu will appear:
Each of the listed options calls a dialog box to perform specific functions. To create a report:
• Call the desired dialog boxes;
• Complete the dialog boxes as desired, then close them;
• Click Calculate and Give Results
• Click the Print button.
176
CHEMCAD Version 5.4 User’s Guide
Flow Rate
Flow rate format
Designates how numbers are to be displayed. Choose from:
F format
E format
G format
No. of digits after the decimal point for fractions
Enter desired value.
Overall Report Format
Choose from: Standard (.DOC file)
Lotus 123 (.PRN file)
Excel (.CSU file)
Excel (; delimiter)
177
User’s Guide CHEMCAD Version 5.4
SELECT STREAMS
The composition and properties of any stream in the flowsheet may be included in the report. The
composition may be expressed in a wide variety of forms (mass flow rates, mole fractions, volumetric
flow rates, etc.) and can be reported in multiple ways within a single report. Stream properties may be
selected from over 70 options. The same composition and properties options are reported for every
stream included in the report. The Select Streams command is used to determine which streams are to
be included.
Selecting the Select Streams option will cause the Select Streams dialog box to appear.
178
CHEMCAD Version 5.4 User’s Guide
• Move the highlight to the first box under the Enter the Stream ID’s: label (by clicking or by
using the [TAB] or [ENTER] keys.
• Type in the stream ID number.
• Move to another box by clicking or by pressing the [TAB] or [ENTER] keys.
• Type in the next stream ID number.
• After all selections have been made click [Save].
Select Unit Operations
The input and output for any UnitOp on the flowsheet can be included in the report. The information
reported is context specific and is determined by the program. You, however, may select which UnitOps
are to be reported.
Selecting the Select Unit Operations option will cause the Select UnitOps dialog box to appear.
179
User’s Guide CHEMCAD Version 5.4
Selecting the Stream Properties options calls the Property Options dialog box.
This dialog box offers two pages of property options. Default options are already checked. To make
selections, turn the check mark in the box next to each option on and off by clicking on it.
Once all selections have been made, click [Save].
180
CHEMCAD Version 5.4 User’s Guide
COMPOSITION OPTION:
The Composition Option prints stream composition with the stream properties. This is in addition to
the stream composition output selected above. You may choose the flow units to be used in this printout
by opening this combo box and selecting the appropriate option, Select Unit Operations
STREAM FLOWRATE/COMPOSITION
Stream compositions can be reported in as many flow and/or composition units as desired. Selecting
the Stream Flowrate/Composition option calls the Flow/Composition Options dialog box which
presents check boxes allowing selection of the desired units. The “check mark” indicates that the option
is turned on. It may be toggled on and off.
DISTILLATION SUMMARIES
The listed options are toggled on and off with the [SPACE BAR] or by clicking with the mouse. The
“check mark” indicates that the option is “turned on”; an empty check box indicates “turned off”.
• Tray Profile – Adds the distillation column profile to the report. It includes reflux ratio,
temperature, pressure, vapor and liquid molar flow on every stage. It also shows flow and
181
User’s Guide CHEMCAD Version 5.4
location of feeds and products. Finally, it gives heat duties and locations of condensers,
reboilers, and side exchangers.
• Tray Properties – This report includes mass flow and transport properties for every stage in
the column.
• Tray Sizing – Prints a report of tray sizing calculations.
• Packed Column Sizing – Generates a report of column sizing for packed columns.
• Tray Compositions – This allows you to select what units to use on the tray-by-tray
composition report. If “No Tray Compositions” is specified, this report is omitted.
HEATING CURVES
This option sets the parameters for heating curves. This involves defining how many points are desired
on the curve and whether the cuts should be based on temperature [Default] or enthalpy.Selecting the
Heating Curves option calls the Heat Curves dialog box.
No. of points: Enter the number of points used to calculate the heating curve. The number of zones
equals the number of points minus one.
Zone cut option: Click the desired option (only one permitted).
• Temperature cut means points will be at intervals of equal temperature.
• H cut with dew/bubble points means that intervals of equal enthalpy are used between the
dew and bubble points (if present).
• Equal H cut means that the points are at intervals of equal enthalpy. The dew and bubble
points are not located or used.
BATCH/DYNAMIC RESULTS
This option allows you to include time dependent output for batch columns, batch reactors, and dynamic
vessels. It calls the Batch/Dynamic Options dialog box.
182
CHEMCAD Version 5.4 User’s Guide
• For batch distillation, you may select print Operation Results (stream compositions and
temperatures at the end of each operation step): print History (stream compositions and
temperatures at each time increment); or print Final Holdups (stage compositions and
temperatures for each time increment.
• For batch reactors, you may print Operations Results and/or Stream and Reactor Mass
Histories.
• For dynamic vessels, you may print Operations Results and/or Stream and Vessel Mass
Histories.
• For individual streams, you may print the composition and temperature Histories.
• For each piece of equipment, you may print the equipment output Histories.
MISCELLANEOUS
Enables the user to toggle on and off the following sections of the output report:
- Topology summary
- Convergence selections
- Thermodynamics selections
- Line sizing results
In the default condition these items are included in the report.
END REPORT
Exits the report module.
183
User’s Guide CHEMCAD Version 5.4
184
CHEMCAD Version 5.4 User’s Guide
1. Select the Output command on the Simulate Flowsheet menu bar. The Output menu will appear.
2. Select the Main PFD option from this menu. A new palette, the PFD Palette, will open and the
program will go into “PFD mode”. The PFD Palette is a modified graphics-editing palette and, as
such, most of its functionality is described in the section “Drawing with the Palette”.
3. Create the PFD by:
• Adding Stream and UnitOp databoxes,
• Adding TP Boxes,
• Adding Title Blocks, symbols, and text,
• Drawing primitives, moving objects, changing colors, etc., as desired.
4. Print the PFD as desired.
5. Exit the PFD mode to reopen the simulation mode commands. The main PFD will remain on the
screen.
See also:
• "Adding a Stream Databox on the PFD"
• "Adding a UnitOp Databox on the PFD"
• "Adding TP Boxes to the PFD
• "How to put text on a drawing"
• "How to move or modify an object"
• "Importing Bitmap"
CREATING SECONDARY PFD’S
A secondary PFD is any PFD, which is not a Main PFD. For any given flowsheet a user may have as
many secondary PFD’s as he/she pleases. Secondary PFD’s are not displayed when the program is in
Edit Flowsheet Mode or Simulation Mode. It is not necessary to have a main PFD in order to have
secondary PFD’s.
The general procedure for creating Secondary PFD’s (process flow diagram) is:
1. Select the Output command on the Simulate Flowsheet menu bar. The Output menu will appear.
2. Select the New PFD option from this menu. The Open dialog box will appear.
3. Enter a name for the PFD in the File name field of the Open dialog box.
4. Close the Open dialog box by clicking the [Open] button.
A New PFD window will open. This window has the commands for creating PFD’s, but no other
commands. In addition, the PFD Palette, will open and the program will go into “PFD mode”. The
PFD Palette is a modified graphics-editing palette and, as such, most of its functionality is described
in the section “Drawing with the Palette”.
185
User’s Guide CHEMCAD Version 5.4
Clicking the Add Stream Box option on the Format menu will initiate a four-step process for placing a
customized stream databox on the PFD. These steps are:
• Select the streams to be included in the databox,
• Select the stream information to be included in the databox,
• Select the databox display settings,
• Move and size the databox as desired.
186
CHEMCAD Version 5.4 User’s Guide
Selecting the Print all Streams option will instruct the program to include in the flowsheet in the stream
databox.
Selecting the Select Streams from flowsheet option will call the Select Streams dialog box. Streams
may then be selected by clicking on them with the cursor, and/or by typing their stream ID No. Only the
selected streams will be included in the stream databox
If neither the Print all streams or the Select streams from flowsheet options are chosen, then streams
may be selected by typing the desired stream ID Nos. directly into the fields provided under Enter the
Stream ID Nos.
After this dialog box is closed (by clicking [OK], the Databox Property Options dialog box will appear.
STEP 2: COMPLETE THE PFD PROPERTIES OPTIONS DIALOG BOX…
187
User’s Guide CHEMCAD Version 5.4
This dialog box is an extremely flexible way of specifying exactly what information you want included in
the stream databox. Notice that there are two pages to this dialog box.
All options on this dialog box are toggle switches except the maximum number of streams in a row,
Composition Option and the Include all components/Select components options (see below) in the
lower middle of the dialog box. A checkmark in the box next to the item label indicates that the property
will be included in the stream databox. Those properties without a checkmark will not be included.
Maximum number of streams in a row – This value specifies how many streams or columns across
the stream databox will be. If more streams are selected than this value, then CHEMCAD will "stack" the
databox. Twelve is the default.
Composition Option – For a given stream databox the material balance may be presented in only one
set of composition units (mole, mass, mole fractions, etc.). You may have as many stream databoxes as
you like and they may include the same streams, but each individual databox will use only one set of
units. To select which is to be used for this databox open the options list by clicking the small triangle to
the right of the current selection. A list of available options will open. You can make your selection by
clicking on it or by moving the highlight with the arrow keys and pressing the [Enter] key when the
desired option is highlighted.
Include all components/Select components – Choose from one of these options by clicking the small
circle next to the label. If you choose the Include all components option, then all components in the
component list for this flowsheet will be included in this stream databox where the heat and material
balance is given. If you choose Select components then when you close the Databox Properties
Options dialog box, the Select PFD components dialog box will appear to enable you to make your
component selections. In the default all of the components are included.
When all selections have been made, click [OK] and the DataBox Settings dialog box will appear.
188
CHEMCAD Version 5.4 User’s Guide
When all selections have been made, click the [OK] button to close the dialog box. The specified stream
databox will appear on the PFD in the upper left-hand corner. You will now need to move it to the
desired location and stretch it to the desired size.
STEP 4: MOVE AND STRETCH THE DATABOX
The stream databox is a Windows object and therefore is moved and stretched like any other Windows
object. Therefore,
To move the databox move the cursor over the databox and press the left button on the mouse. While
holding the left button down, slide the mouse around. The databox will move with the mouse. In this
fashion, move the databox to its desired location.
To stretch the databox move the cursor over the databox and press the left button on the mouse once.
This is called selecting the object (databox) and when you do it four little, black squares will appear, one
at each corner of the object (databox). To resize or stretch the databox, move your cursor so that the tip
of the arrow (cursor) is directly over one of these little, black squares. Then, while holding down the left
button, slide the mouse around. The databox will change size and aspect ratio as you do this. In this
fashion enlarge or shrink the databox to the size you want.
Clicking the UnitOp Box option on the Format menu will initiate a three-step process for placing a
customized UnitOp databox on the PFD. These steps are:
• Select the UnitOps for which you want to generate a databox. An individual databox will be
generated for each UnitOp selected.
• Select the databox display settings.
• Move and size the databox as desired.
189
User’s Guide CHEMCAD Version 5.4
Select units from flowsheet - Selecting the Select units from flowsheet option will call the Select
UnitOps dialog box. UnitOps may then be selected by clicking on them with the cursor, and/or by
typing their ID No. Only the selected UnitOps will be included in the UnitOps databox.
If the Select Units from flowsheet option is not chosen, then streams may be selected by typing the
desired UnitOp ID Nos. directly into the fields provided under Enter the Unit ID Nos.
When all of the Wordpad windows have been closed, the program will proceed by opening the Data Box
Settings dialog box.
Click [OK] when the desired UnitOps have been identified. The Data Box Settings dialog box will then
appear.
STEP 2: COMPLETE THE DATABOX SETTINGS DIALOG BOX
190
CHEMCAD Version 5.4 User’s Guide
The UnitOps databox is a Windows object and therefore is moved and stretched like any other Windows
object. Therefore,
To move the databox move the cursor over the databox and press the left button on the mouse. While
holding the left button down, slide the mouse around. The databox will move with the mouse. In this
fashion, move the databox to its desired location.
To stretch the databox move the cursor over the databox and press the left button on the mouse once.
This is called selecting the object (databox) and when you do it four little, black squares will appear one
at each corner of the object (databox). To resize or stretch the databox, move your cursor so that the tip
of the arrow (cursor) is directly over one of these little, black squares. Then, while holding down the left
button, slide the mouse around. The databox will change size and aspect ratio as you do this. In this
fashion enlarge or shrink the databox to the size you want.
Clicking the Add TP Box option on the Format menu will initiate the process for placing customized
temperature, pressure, and/or flowrate boxes on the flowsheet for selected stream(s). The steps to add
a TP box are:
- Decide if you want the TP boxes generated for all streams or selected streams on the flowsheet.
- Select the T, P, and/or F options (and their formats) which you want displayed on the PFD.
191
User’s Guide CHEMCAD Version 5.4
- Select streams for TP boxes (unless generate boxes for all streams was chosen).
- Move the TPF boxes as desired.
192
CHEMCAD Version 5.4 User’s Guide
Display Units
This allows the user to toggle on and off the engineering units in which each value is displayed.
Stream ID’s
Includes the stream ID in the TPF box.
SELECT STREAMS FROM FLOWSHEET
If the options Select Streams…was chosen (above), when the user presses OK a select streams dialog
will appear. Left click on the stream lines or type the desired stream numbers and press OK.
Note: In order to run in the dynamics mode in CHEMCAD, you must own a
license for a dynamic unit operation (CC-ReACS or CC-DCOLUMN)
The CHEMCAD Suite contains a library of the following dynamic unit operations:
Batch reactor
Dynamic Column (SCDS, TPLS, TOWR)
Tank
Time switch
Dynamic vessel
Time delay
Control valve
PID controller
Ramp controller
Any CC-STEADY STATE UnitOp can be run in the dynamic mode. Doing this may or may not make
sense depending on how you set up the problem. Implicit in using a steady-state UnitOp in a dynamic
flowsheet is the assumption that the dynamics of that UnitOp are very fast.
Notes: 1. For a description of the dynamic UnitOps, refer to the on-line manual.
2. Although the batch distillation module performs a dynamic calculation,
it is currently set up to run in the steady-state mode only.
For the description given below, no attempt is made to duplicate material covered elsewhere in this
manual. Instead, reference is made to other sections for more detailed descriptions whenever possible.
The steps for setting up a dynamic flowsheet are:
1. Start a new job
193
User’s Guide CHEMCAD Version 5.4
Refer to sections:
How to Start a New Job
CHEMCAD Tutorial for Windows: Starting a New Job
CC-BATCH Tutorial: Starting a New Job
SELECTING ENGINEERING UNITS
Refer to sections:
How to Select Flowsheet Engineering Units
CHEMCAD Tutorial for Windows: Selecting Engineering Units
CC-BATCH Tutorial: Selecting Engineering Units
DRAW THE FLOWSHEET
Dynamics flowsheets are drawn exactly the same way that steady-state flowsheets are drawn. Please
note however, that not all dynamic UnitOps have to have inlets and outlets. They can accumulate.
For instructions on how to draw flowsheets in CHEMCAD, please refer to sections:
How to Draw a Flowsheet
Graphics in CHEMCAD – An Overview
How to Add UnitOps to the Flowsheet
Drawing Streams
194
CHEMCAD Version 5.4 User’s Guide
This is done on the Convergence dialog box under the Run command on the main menu bar.
Sometimes the program turns it on automatically based on the presence of certain dynamic UnitOps.
Procedure:
1. Click the Run command on the main menu bar. The following menu will appear:
2. Click the Convergence option at the top of the menu. The Convergence Parameters dialog box
will appear:
3. In the lower right-hand corner of this dialog box is a combo box labeled Steady State/Dynamics.
Open this box by clicking on it. The options Steady State and Dynamics will appear.
4. Click on the Dynamics option. The combo box will close and the word Dynamics will show.
5. Click the [OK] button to close the dialog box and save the selection.
195
User’s Guide CHEMCAD Version 5.4
SELECT COMPONENTS
Refer to sections:
How to Select Components for the Components List
CHEMCAD Tutorial for Windows: Selecting Components
CC-BATCH Tutorial: Selecting Components
SELECT THERMODYNAMIC OPTIONS
Refer to sections:
How to Select K-Value Options
How to Select Enthalpy Options
CHEMCAD Tutorial for Windows: Selecting Thermodynamic Options
CC-BATCH Tutorial: Selecting Thermodynamic Options
SPECIFY FEED STREAMS AND STREAM INITIAL CONDITIONS
In a dynamic simulation, as in a steady state simulation, all feed streams must be defined. That means
that the composition, flowrate, and thermodynamic properties (two of T, P, and VF) must be given.
Sometimes the flowrate is reset by a control valve, during the simulation, but some flowrate must be
given. As always, the program must know the composition and enthalpy at all times.
In addition to the feed streams, it is sometimes important to know the contents and conditions of the
intermediate streams at time zero. You must also give these conditions when necessary.
Input for all streams is provided in the same way. For a description of this input procedure, refer to
sections:
How to Define the Feed Streams
CHEMCAD Tutorial for Windows: Defining the Feed Stream
CC-BATCH Tutorial: Defining the Feed Streams
SPECIFYING UNITOPS
This function is performed using either the Dynamic Menu (on the Run Menu or the Set Run Time
power button on the Toolbar.
This command is used to set the simulated time of the dynamics run and to specify the time step size
(how often the flowsheet equations are integrated). These items must be specified for the calculation to
proceed. Clicking this option will cause the following Set Simulation Run Time dialog box to be
196
CHEMCAD Version 5.4 User’s Guide
displayed. For each operating step, this dialog box will have fields for the duration of the operating step,
the number of time steps per operating step, and the stop criteria.
Please take note of the following:
1. More than one operating step can be specified. If a run is made from time zero (i.e., the initial
state), all specified operating steps will be run. If the simulation is being run from the current state,
then only those operating steps beyond the current time will be run.
Operating steps can be added at any time, so this feature provides a facility for extending the
dynamic simulation indefinitely.
2. The time stepsize is specified in the Step size field
3. The criteria for terminating one operating step and moving to the next one can be set by specifying
elapsed time or the occurrence of some event in the flowsheet. The overall simulation time is then
equal to the sum of the total simulation times for each step.
RUNNING THE DYNAMIC SIMULATION
Dynamic simulations are run from the Dynamics menu. The Dynamics menu is located on the RUN
menu which is accessed by clicking the Run command on the Top Level Menu Bar of the Simulate
Flowsheet window. Therefore, to get to the Dynamics menu, do the following:
1. Select the Run command from the menu bar. The Run menu will appear.
2. Click the Dynamics option on Run menu. The Dynamics menu will appear.
197
User’s Guide CHEMCAD Version 5.4
198
CHEMCAD Version 5.4 User’s Guide
199
User’s Guide CHEMCAD Version 5.4
At the end of any dynamic simulation, CHEMCAD will know the following:
1. All of the numbers at time zero, i.e., the entire initial state.
2. All of the numbers at the ending time of the simulation, i.e., the entire final state.
3. The recorded numbers at each time in-between the initial and final states, i.e., selected portions of
the intermediate states.
Dynamic runs can be made only from states or times that are completely known. Therefore, in
CHEMCAD, dynamic runs can only be made from time zero or from the current state.
RE-RUNNING FROM TIME ZERO:
To rerun a simulation from time zero:
200
CHEMCAD Version 5.4 User’s Guide
1. Restore to initial state using the Restore to initial state command on the Dynamics menu or on
the Toolbar.
2. Make any desired changes to the initial state using the usual commands or on the Toolbar.
3. Rerun the simulation by clicking the Run from Time Zero command on the Dynamics menu.
RUNNING FROM THE CURRENT TIME:
To extend the simulation from the current state or time:
1. Open the Runtime dialog box by clicking the Set runtime command on the Dynamics menu or on
the Toolbar.
2. Add 1 to the current number shown in the No. of Operating Steps field, and enter the result in this
field. In other words, increment the number of operating steps by one.
3. Select the tab for the new operating step and complete the screen input in the same manner as
previous operating steps.
4. Close the Runtime dialog box.
5. Click the option Run from current time on the Dynamics menu or on the toolbar. The simulation
will begin.
You should note that some input changes can be made before extending the run. However, changes
made to certain variables after time zero may create thermodynamic inconsistencies. To prevent this,
CHEMCAD denies access to these variables unless the initial state has been restored.
Once the initial state has been restored, it is no longer possible to run from the current state.
To run a sensitivity analysis you must call the Sensitivity Analysis menu, which looks like this:
201
User’s Guide CHEMCAD Version 5.4
4. Enter a name for the sensitivity analysis, then click [OK]. The following menu will appear;
5. Specify the parameter(s) to be varied by clicking the Edit Independent Variable and (if two
independent variables are being used) the Edit Independent Parameters option and then
completing the Independent Variables dialog box.
6. Specify the variables to be recorded by clicking the Edit Recorded Variables option and completing
the Recorded Variables dialog box.
7. Select either the Run or the Run Selected Units option on the above menu. The normal
calculation sequence will be initiated. Therefore, the program will now check the input data and
display a message window if any warnings or errors exist.
8. Close the message window. If any errors are present, the calculation sequence will be terminated
and you will be returned to the Sensitivity Analysis menu. If no errors were present, and you have
activated the Display trace window on the Convergence dialog box, you will proceed to the
CHEMCAD Trace Window and Step 9 below. If the Display trace window option has not been
activated, the CHEMCAD Trace Window will not be displayed and you will proceed directly to the
calculations and step 12 below. (Please note that if no errors or warnings are present, no message
window will appear and this step will be skipped altogether).
9. Click the Go button. The sensitivity analysis will proceed and runtime messages will be sent to the
screen as the calculation proceeds. When the analysis is finished, the message Run finished will
appear at the bottom of the CHEMCAD Trace Window.
10. Using the elevator bar of the CHEMCAD Trace Window you may now browse the runtime
messages if so desired. Click the Close button to close the CHEMCAD Simulation Window. You
will be returned to the Sensitivity Analysis menu.
11. From the Sensitivity Analysis menu select Plot Results. The Sensitivity Analysis-XY Plot
dialog box will appear.
12. The fields “Plot Title”, “Title (continued)”, “X axis label” and “Y axis label” are text fields providing
labels for the plot. The combo-check box in the lower left-hand corner lists all of the dependent
variables that were recorded during the sensitivity analysis calculations. The presence of a
checkmark in the box next to a variable means it will be included on the plot.
202
CHEMCAD Version 5.4 User’s Guide
Enter the labels and select the plot variables as desired. Then click [OK]. The plot will appear in a plot
window.
The Independent Variable dialog box allows the user to specify the independent variable, or, in the
case where two independent variables exist, the first independent variable. The independent variable(s)
will be varied over a range of values in a defined number of steps. Because CHEMCAD can only plot
and report in two dimensions, no more than two independent variables are permitted in any given
sensitivity analysis.
VARIABLE IDENTIFICATION:
The variable identification convention used throughout CHEMCAD is:
1. Identify if the variable is a stream variable or a UnitOp variable using a choice box.
Click the appropriate circle to make a selection. The dot inside the circle indicates the current
selection.
2. Enter the object ID. The object ID is the ID number of the stream or UnitOp. The object ID for
stream number 4 is 4; the object ID for UnitOp number 2 is 2; etc. The object ID must be typed in.
3. Identify the Variable. Each stream or UnitOp has multiple variables associated with it. The user
must identify which one is to be varied. Once the stream or UnitOp is identified in steps one and
two above, CHEMCAD knows the correct variable list. When you click on the Variable field, this list
will be displayed. You can then scroll the list, and select the proper option by clicking on it or by
highlighting it and pressing the [Enter] key.
4. Identify the type of engineering units of this independent variable using the Variable Units field. In
other words, if the variable is a temperature, you should select “temperature” on the Variable Unit
list; if the variable is a pressure, you should select “pressure” from the Variable Unit list; etc. If this
identification is not made, the program will assume the variable is in internal CHEMCAD units (ºR,
psia, etc.)
5. In some cases the variable identified may involve a component. If so, identify which component in
the Comp field. Click on the field. CHEMCAD will display a list of the components for the current
job. Select from this list to close the field.
6. Give a Variable name. This step is optional. It provides a label for the plot.
203
User’s Guide CHEMCAD Version 5.4
The Optimization option under the Run menu allows you to maximize or minimize a stream or unit
operation variable (Objective Function) given certain independent variables and constraints.
IMPORTANT NOTE: Always make a backup copy of your job before beginning an
optimization. This way, if the optimization introduces any instability or causes
your flowsheet to stop converging, you still have a fully functional version of
your job available.
When you first select the Optimization option, you will see the following screen:
204
CHEMCAD Version 5.4 User’s Guide
Define Objective Function – this option allows you to specify which stream or unit operation variable
you would like to minimize or maximize, and it brings up the following screen:
205
User’s Guide CHEMCAD Version 5.4
206
CHEMCAD Version 5.4 User’s Guide
iii. X <= Value 1 – the variable must be less than or equal to Value 1
iv. X >= Value 1 – the variable must be greater than or equal to Value 1
v. X = Value 1 – use this option to fix the variable at Value 1
Constraints – this allows you to specify that up to 10 dependent variables to be constrained. When you
select this option, the following screen appears:
207
User’s Guide CHEMCAD Version 5.4
iii. X <= Value 1 – the variable must be less than or equal to Value 1
iv. X >= Value 1 – the variable must be greater than or equal to Value 1
v. X = Value 1 – use this option to fix the variable at Value 1
Settings – This option allows you to specify miscellaneous optimization options. The following screen
appears when you select this option:
208
CHEMCAD Version 5.4 User’s Guide
CHEMCAD provides a utility called Symbol-Builder, which is used to build and save user added
symbols and icons. Symbol-Builder is called by clicking on the Edit command on the menu bar. The
Edit Menu will appear. At the bottom of the menu is the Symbol Builder command. Click on it and the
following window will open:
209
User’s Guide CHEMCAD Version 5.4
• Graphics – Allows settings of fill patterns, pen size, arrow direction, etc.
• Palette – Opens, creates, and saves UnitOp and symbol palettes. Also controls the
dimensions of the CC-Builder palette.
• Window – Controls the display of open windows.
• Help – Provides access to the CHEMCAD help system.
These commands along with the palette provide the tools from building and saving icons and symbols.
The CC-Builder palette is the primary tool for the creation of icons and symbols. The palette has eleven
squares each of which provides a graphics or icon creation function. These functions are:
The rotation function will
rotate any graphics object The rectangle function draws
through any angle. rectangles and squares.
Use of the rotation, rectangle, ellipse, line, multiline, polygon, and text functions are described in the
following sections of this User’s Guide:
210
CHEMCAD Version 5.4 User’s Guide
211
User’s Guide CHEMCAD Version 5.4
212
CHEMCAD Version 5.4 User’s Guide
213
User’s Guide CHEMCAD Version 5.4
214
CHEMCAD Version 5.4 User’s Guide
215
User’s Guide CHEMCAD Version 5.4
216
CHEMCAD Version 5.4 User’s Guide
217
Process Simulation Essentials
Example Book
All material © 2021 Chemstations, Inc.
Table of Contents
1 – Thermodynamics
Thermodynamics Selection: Chemicals.................................................................................... 3
Thermodynamics Selection: Hydrocarbons .............................................................................. 5
Global and Local Thermodynamics .......................................................................................... 7
Binary Interaction Parameter (BIP) Regression ........................................................................ 8
2 – Phase Equilibria
Flash Calculations .................................................................................................................. 10
Vapor-liquid Equilibrium: Non-ideal Systems .......................................................................... 12
Vapor-liquid Equilibrium: Azeotropes ..................................................................................... 14
Vapor-liquid-liquid and Liquid-liquid Equilibrium ..................................................................... 17
3 – Separators
Distillation Basics: Benzene/Toluene ..................................................................................... 18
Distillation Models in CHEMCAD............................................................................................ 20
Column Design: Benzene/Toluene/Xylene ............................................................................. 22
Column Performance: Benzene/Toluene................................................................................ 24
Absorption and Stripping ........................................................................................................ 26
Liquid-liquid Extraction ........................................................................................................... 28
Ethyl Acetate by Reactive Distillation ..................................................................................... 29
1
4 – Reactors
Reactor Models in CHEMCAD ............................................................................................... 30
EREA Shift and Methanation Reactors................................................................................... 31
Equilibrium Reactor (EREA) ................................................................................................... 33
Kinetic Reactor (KREA) .......................................................................................................... 34
5 – Heat Exchangers
Heat Exchangers: Principles and Applications ....................................................................... 36
Heat Exchangers: Use Cases ................................................................................................ 38
Heat Exchangers: Equipment Design, Sizing, and Costing .................................................... 40
Heat Exchangers: CC-THERM Modes ................................................................................... 42
6 – Recycle
Recycle: Closing the Loop...................................................................................................... 44
Nested Recycle: Closing the Inner Loop ................................................................................ 45
Nested Recycle: Closing the Outer Loop................................................................................ 46
7 – Pressure
Flow Models: Input Specifications .......................................................................................... 47
Single-branch Piping Configurations ...................................................................................... 49
8 – Reports and Charts
Reports: Benzene/Toluene/Xylene Distillation ........................................................................ 51
Charts: Phase Equilibria ......................................................................................................... 53
Charts: Benzene/Toluene Distillation ..................................................................................... 55
Charts: Exchangers and Plug Flow Reactor ........................................................................... 57
9 – Tools
Tools: UnitOps ....................................................................................................................... 59
Tools: META UnitOp .............................................................................................................. 60
Tools: Child Simulation for META UnitOp ............................................................................... 61
Tools: Sensitivity Analysis ...................................................................................................... 63
Controller: Simple Applications .............................................................................................. 65
Controller: Refrigeration Cycle ............................................................................................... 66
Controller: Separators ............................................................................................................ 68
2
Thermodynamics Selection: Chemicals
The selection of K-value and enthalpy models is the most critical step in process
simulation. An improper selection leads to unreliable results.
Once you have selected all the components involved in the process, the Thermodynamic
Suggestions dialog box will appear. You can either click Cancel to enter thermodynamics
manually, or enter the desired parameters. In this example, an equimolar mixture of
acetonitrile and benzene is flashed with specified P = 101325 and mole vapor fraction =
0.05.
With this example, you can learn about the typical K-value models used for non-ideal
solutions. These K-value models are based upon the excess Gibbs free energy and use
activity coefficient methods (e.g., Wilson, NRTL, UNIQUAC, and UNIFAC), as well as
binary interaction parameters (BIPs).
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Types of Solutions" and "Thermodynamics."
Note: Use the suggestions of the algorithm as a guide only. Proper selection of
thermodynamics is the engineer's responsibility. Your simulation may call for the use of a
different model.
3
For instance, the acetonitrile/nitromethane system is fairly ideal, and using the Ideal
Vapor Pressure (Raoult's Law) or an activity coefficient model (NRTL, UNIQUAC) won't
make much difference. This is not the case for acetonitrile/benzene or benzene/water,
where the departure from ideal behavior is strong. For instance, the acetonitrile/benzene
forms an azeotrope, and the benzene/water system exhibits liquid-liquid and vapor-
liquid-liquid equilibrium.
Note: In the K-value Models tab, change the Global Phase Option to
Vapor/Liquid/Liquid/Solid so that if liquid-liquid equilibrium exists, Stream 3 will
contain the light liquid phase.
To use this example, select a pair of components and specify composition in the feed.
Open the Thermodynamic Settings dialog and change the Global K-value Model
setting. Run the simulation and evaluate the results for the liquid streams. Notice any
differences among Ideal Vapor Pressure (VAP), NRTL, UNIQUAC, and UNIFAC. Notice if
more than one liquid phase exists.
To generate the TXY diagram and XY diagram for any pair of components in this
simulation, click the Charts drop-down in the Results group of the Home tab, then
select TPXY under the Thermodynamic category.
4
Thermodynamics Selection: Hydrocarbons
The selection of K-value and enthalpy models is the most critical step in process
simulation. An improper selection leads to unreliable results.
Once you have selected all the components involved in the process, the Thermodynamic
Suggestions dialog box appears. You can either click Cancel to enter thermodynamics
manually, or enter the desired parameters. In this example, a mixture of hydrocarbons
and water is flashed at T = 300 K and P = 690 kPa.
Considering the components and the temperature and pressure range, the algorithm
suggests Soave-Redlich-Kwong (SRK) as both the K-value and enthalpy models. The
next step is the Thermodynamic Settings dialog box, where you can make further
changes or override the selection made by the algorithm. Notice that the
Water/Hydrocarbon Solubility option is marked as Immiscible. As a result, Stream 4 has
pure water.
Note: If water is not part of the process but is used as a utility, it is recommended that
you select water as a component to ignore in the Thermodynamic Suggestions dialog
box, to prevent a misleading selection.
5
Importance of the specified temperature and pressure range: Suppose the
process occurs at very low temperature ( < -70 °C) and high pressure ( > 10000000
Pa). Open the Thermodynamic Suggestions dialog and enter a temperature range of 180
to 250 K and a pressure range of 101325 to 1e+06 Pa.
Notice how the temperature and pressure range affects the selection. The algorithm now
suggests Peng-Robinson (PR) instead. PR is a common selection when the process
conditions are extreme.
Note: Use the suggestions of the algorithm as a guide only. Proper selection of
thermodynamics is the engineer's responsibility. Your simulation may call for the use of a
different model.
6
Global and Local Thermodynamics
A mixture of ethanol and water at 170 °F and atmospheric pressure is used for this
example. Both Flash UnitOps have the same specifications.
To review or change the Global K-value: on the Home tab, in the Setup group, click
Thermodynamic Settings, then click the Global K-value Model drop-down list.
To set local thermodynamics: on the Home tab, in the Setup group, click
Thermodynamic Settings, then check the Set local thermodynamics option. Click
OK, then enter 2 for the UnitOp ID and click OK again. A new dialog box will appear,
where you can select a different K-value (and/or enthalpy model) for the selected
UnitOp.
To review the thermodynamics for the flowsheet, click the Reports drop-down (Home
tab, Results group). Under the Flowsheet heading, choose Thermodynamics. Notice
that the vapor fraction and enthalpy of the feed are governed by the Global K-value.
Then, the Flash UnitOp flashes the feed using the local K-value, thus giving a slightly
different result.
This feature is often used when the phase equilibrium calculations for a unit within the
process require a particular Equation of State or Activity Coefficient model.
7
Binary Interaction Parameter (BIP) Regression
This example details how to review available BIPs in CHEMCAD's database, enter BIPs
manually, and regress BIPs from VLE data. This is an advanced topic.
To learn more about BIPs, press [F1] to open the CHEMCAD help file, then see the help
topic called "Overview of BIPs in CHEMCAD."
First, three BIP sets were created (Home tab, Setup group, Thermodynamic
Settings, K-value Models tab, enter 3 under No. of BIP sets).
Set 1 uses built-in BIPs from CHEMCAD's database. Click the Component Database
tab, then in the System Database group, click the BIP Data drop-down and choose
Database BIPs. Choose any pair of components to review available BIPs.
Set 2 has BIP parameters entered manually. Click the Thermophysical tab, then in the
Binary Interactions group, click Edit BIPs. Here, the recommended values found in
DECHEMA's Chemistry Data Series - Vapor-Liquid Equilibrium Data Collection for the
Acetone/Water binary system were entered in the Bij, Bji, and Alpha ij columns, thus
overriding CHEMCAD's built-in parameters.
Note: the values as shown on the reference have been divided by Gas constant R in
CHEMCAD R = 1.98721 cal/mol/deg.K to make them comparable to CHEMCAD's.
Set 3 was created after regressing VLE data for acetone (1)/water (2) at a constant
pressure of 1.013 bar from the same source. To perform a BIP regression, click the
Thermophysical tab, then in the Binary Interactions group, click BIP Regression.
8
Select the components, then Regress TPxy/Pxy/Txy VLE data and enter data in the
appropriate columns. (For more, see the "BIP Regression" help topic.)
Note: The first component you select will be treated as the i component by the program.
Make sure that your selection matches the proper i component in the VLE data.
Review the flowsheet specifications and BIPs by clicking the Reports drop-down (Home
tab, Results group) and choosing Thermodynamics under the Flowsheet heading.
Note: i and j refer to the order in the component list (i.e., acetone = 1; water = 2).
To compare the results, activate the BIP set first (Home tab, Setup group,
Thermodynamic Settings, K-value models tab). In the Default BIP set field, type
the number of the BIP set of interest, then run the simulation. Do results differ when
using the various BIP sets?
Reference:
Gmehling et al. "Vapor-Liquid Equilibrium Data Collection," Chemistry Data Series, vol. I,
part 1b, DECHEMA, Frankfurt/Main, 1988. pp. 146 and 153.
9
Flash Calculations
In Vapor-Liquid Equilibrium (VLE), liquid and vapor phases coexist in equilibrium. When
the overall composition is known (feed composition), then two variables are required to
fix the state of the system.
Based on the feed composition and conditions, the Flash UnitOp calculates the other
variables, as well as the quantities and compositions of the vapor and liquid phases in
equilibrium.
Modes 6 and 7: Specify P or T and perform isentropic flash, respectively (not shown in
this example).
Modes 8 and 9: Specify P or T and water dew point T or P, respectively (not shown in
this example).
This example shows the typical Flash calculations using an equimolar mixture of benzene
(1)/ethylbenzene (2), which is wide-boiling and thus easily separated.
10
Additional exercises:
d) Benzene (1)/cyclohexane (2) mixture at various compositions. Can you find the
azeotropic composition?
To generate binary TPXY charts, click the Charts drop-down (Home tab, Results group)
and select TPXY. Specify the two components (1 for the most volatile) and either
constant pressure (PXY) or constant temperature (TXY).
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 341-347, 367-369.
11
Vapor-liquid Equilibrium: Non-ideal Systems
In this example, the Flash UnitOp is used to model a single vapor-liquid equilibrium
stage.
All Flash UnitOps have Mode 2 specified (Specify T and P; calculate V/F and Heat). You
can specify other modes to perform various calculations. See the example called
_Process Simulation Essentials\2 Phase Equilibria\1 - Flash calculations.
With this example, you can learn about the typical K-value models used for non-ideal
solutions. These K-value models are based upon the excess Gibbs free energy and use
activity coefficient methods (e.g., Wilson, NRTL, UNIQUAC, and UNIFAC), as well as
binary interaction parameters (BIPs).
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Types of Solutions" and "Thermodynamics."
CHEMCAD has built-in BIPs from numerous chemical components in the database. Click
the Component Database tab, then in the System Database group, click the BIP
Data drop-down and choose Database BIPs. Choose any pair of components to review
available BIPs.
12
Notice how the K-value selection determines the molar rate and composition for the
vapor and liquid products once the flash calculation is performed.
Click Stream Box (Drawing tab, Insert group) and then click Product Streams to
generate a table to compare the K-value models side by side.
You can test for two different systems as specified below. This example has case a) set
up and NRTL as the global K-value.
a) Positive deviation from Raoult's Law: Methyl Ethyl Ketone (1)/Toluene (2) at T = 50
°C and P = 20 kPa
Local K-values have been used for the Flash UnitOps. The first Flash UnitOp (1) has
Global K-value, which can be modified by clicking Thermodynamic Settings (Home
tab, Setup group) and then clicking the Global K-value Model drop-down.
Note: Charts are generated using the Global K-value. Match the Global K-value to any of
the K-value models in the flowsheet. Then run the top Flash UnitOp (1). Select Stream 1
and then generate a TPXY chart (Home tab, Results group, Charts drop-down,
Thermodynamic heading, click TPXY).
Note: The use of local thermodynamics is for illustrative purposes as it is not typical to
have that many local K-value models in a single flowsheet.
Review the flowsheet specifications and BIPs for each activity coefficient by generating a
Thermodynamics report (Home tab, Results group, Reports drop-down, Flowsheet
heading, click Thermodynamics). Note that I and J refer to the order in the component
list.
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 348-350, 352-356, 435-439.
13
Vapor-liquid Equilibrium: Azeotropes
In this example, the Flash UnitOp is used to model a single vapor-liquid equilibrium
stage.
All Flash UnitOps have Mode 1 specified (Specify V/F and P; calculate T and Heat). You
can specify other modes to perform various calculations. See the example called
_Process Simulation Essentials\2 Phase Equilibria\1 - Flash calculations.
With this example, you can learn about the typical K-value models used for non-ideal
solutions. These K-value models are based upon the excess Gibbs free energy and use
activity coefficient methods (e.g., NRTL, UNIQUAC, and UNIFAC), as well as binary
interaction parameters (BIPs).
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Types of Solutions" and "Thermodynamics."
Activity coefficient methods are used in processes where the solution is non-ideal or
highly non-ideal, two liquid phases may exist, and azeotrope(s) may exist.
CHEMCAD has built-in BIPs from numerous chemical components in the database. Click
the Component Database tab, then in the System Database group, click the BIP
Data drop-down and choose Database BIPs. Choose any pair of components to review
available BIPs.
14
The purpose of this example is to determine whether the mixture forms an azeotrope,
and if so, at what temperature and composition this occurs.
Azeotropic mixtures are liquid mixtures that exhibit sufficiently large deviations from
Raoult's Law behavior. As a result, the T-x and T-y curves exhibit a minimum (positive
deviations) or a maximum (negative deviations) at constant pressure. At the azeotropic
point x1 = y1 and the dew point and bubble point curves intersect. A boiling liquid of this
composition (azeotropic point) produces a vapor of the same composition. No separation
is possible by distillation since the solution is constant boiling.
Notice how the K-value selection determines the azeotropic temperature and
composition. Notice that the Ideal Vapor Pressure and SRK models fail to detect
azeotropes.
2) Test whether or not a K-value method can predict the existence of such an azeotrope.
3) Estimate the azeotropic temperature and azeotropic point by looking at the TXY
diagram (Home tab, Results group, Charts drop-down, Thermodynamic heading,
click TPXY) and specifying pressure at 1 bar.
4) Estimate the azeotropic pressure and azeotropic point by looking at the PXY diagram
(again, click TPXY from the Charts drop-down) and specifying the temperature in
Celsius.
5) Perform flash calculations to determine dew point and bubble point of mixtures. At the
azeotropic composition, bubble T = dew T (for constant P).
Is the azeotropic temperature and composition the same for all K-values?
Is the azeotropic temperature and composition the same when you change the pressure?
Which of the K-values does not predict the existence of the azeotrope (when there is
one)?
Ethanol (1)/water (2); ethanol (1)/benzene (2); ethanol (1)/cyclohexane (2); ethanol
(1)/toluene (2); benzene (1)/cyclohexane (2); benzene (1)/toluene (2).
15
This example shows the ethanol (1)/water (2) system at constant P = 1 bar. The
composition of the feed is close to the azeotropic point.
Local K-values have been used for the Flash UnitOps. The first Flash UnitOp (1) has a
global K-value, which can be modified by clicking Thermodynamic Settings (Home
tab, Setup group) and then clicking the Global K-value Model drop-down.
Note: TPXY charts (Home tab, Results group, Charts drop-down, Thermodynamic
heading, click TPXY) can be generated using any K-value. Under Specify
thermodynamics, use the K-value drop-down to select a K-value model. Click Add Row
to compare the results from different K-value models on the same chart. By default,
rows are initialized using the Global K-value.
Note: The use of local thermodynamics here is for illustrative purposes, as it is not
typical to have that many local K-value models in a single flowsheet.
Review the flowsheet specifications and BIPs for each activity coefficient using the
Thermodynamics report (Home tab, Results group, Reports drop-down, Flowsheet
heading, Thermodynamics).
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 347-355, 446-449, 474-475.
16
Vapor-liquid-liquid and Liquid-liquid Equilibrium
In this example, water is mixed with an organic feed and flashed at the inlet temperature
and pressure conditions.
NRTL was selected as the K-value for this example because it can predict liquid-liquid
equilibrium.
Note: The Global Phase Option has been changed to Vapor/Liquid/Liquid/Solid to allow
this calculation. This is set by clicking Thermophysical Settings (Home tab, Setup
group) and then selecting a Global Phase Option on the K-value Models tab.
To plot a TXY or PXY diagram, select stream 3 and generate a TPXY chart (Home tab,
Results group, Charts drop-down, TPXY). Select the pair of components, fix the
pressure (or temperature), and click OK to generate a TXY diagram and XY diagram.
What if you change the temperature of the organic feed to 170 °F? Is there a vapor
phase?
What if you add ethanol to the water feed? Does ethanol split into the liquid phases?
What is the phase distribution and composition if UNIQUAC or UNIFAC is used? To find
out, click Thermodynamic Settings (Home tab, Setup group) and then select
UNIQUAC as the Global K-value Model on the K-value Models tab.
17
Distillation Basics: Benzene/Toluene
For an equilibrium stage at a given pressure, the range of possible product compositions
is bounded by the bubble point and dew point compositions at that pressure.
This concept is better understood by looking at the TXY diagram. On the Home tab, in
the Results group, click the Charts drop-down. Under the Thermodynamic heading,
choose TPXY and select the components in order of relative volatility (benzene = 1,
toluene = 2) at constant pressure of 1.72 bar. CHEMCAD generates TXY and XY charts.
Starting at 0.4 mole fraction of benzene (the feed composition), intersect the bubble
point (bottom curve) and dew point (top curve) at T = 118 °C. These are the mole
fractions of benzene in the liquid and vapor products, respectively. These in turn become
the feed compositions for streams 5 and 6. For stream 5, find the intersection with T =
115 °C to find the compositions of streams 7 and 8. Notice how the mole fraction of
benzene in the vapor increases continuously. The same can be done for stream 6 by
finding the intersection of the curves with T = 120.5 °C
18
Notice how the mole fraction of benzene in the liquid product decreases continuously. As
more equilibrium stages are added, benzene concentrates in the vapor, while toluene
concentrates in the liquid.
For this example, a Tower distillation column with 10 stages was used to separate the
mixture. The reflux ratio was set at 1 and the bottoms mole rate at 50 kmol/h.
19
Distillation Models in CHEMCAD
CHEMCAD offers both shortcut and rigorous methods for solving multicomponent
distillation problems. The shortcut method uses non-rigorous thermodynamics, and is
based on the assumption of constant molal overflow, which does not happen in reality.
Both rigorous methods use thermodynamics to calculate mass and energy balances,
which model real behavior.
The Shortcut model (SHOR) uses the Fenske-Underwood-Gilliland method. Both rating
and design cases are provided.
For this example, design mode was used to calculate the minimum number of stages
required when reflux ratio and the split fractions of light key and heavy key components
are specified.
Note: This method may not be suitable for column design and may give incorrect results
in systems with azeotropes. It should be used to obtain only an estimate for the
minimum number of stages before designing a Tower or SCDS column.
The Tower model (TOWR) uses the inside-out rigorous method for multistage VLE.
The Tower Plus model (TPLS) uses the inside-out rigorous method too, but allows for
complex columns. This model is used for petroleum and refining applications. To learn
more, see "Atmospheric distillation of crude oil" under the Distillation and Absorption
folder.
20
The SCDS model (SCDS) uses the simultaneous corrections method for multistage VLE.
For this example, all three rigorous models were specified in the same way. They use
different mathematical algorithms and number of iterations to converge to a solution,
but the solution will be the same. When computers were less powerful, the choice
between TOWR and SCDS was related to the process in question. TOWR usually requires
fewer iterations and converges faster, but this is not as relevant using modern
computers. However, the SCDS allows for special distillation cases that TOWR does not
support.
All three rigorous models will solve standard absorbers, strippers, and fractionators, with
and without reboilers, condensers, multiple feeds, and multiple draws. The choice among
models is more easily made by exception:
SCDS: 1) Tray efficiency less than 100% (Murphree efficiency); 2) Mass transfer model
(packed or tray column); 3) Reactive distillation; 4) Highly non-ideal thermodynamics;
5) Electrolytes.
To learn more, press [F1] to open the CHEMCAD help file, then search for the help topic
that addresses the particular distillation model.
21
Column Design: Benzene/Toluene/Xylene
The first step is to design a column that separates mostly benzene in the overhead. This
requires guessing or estimating the column stages, feed tray location, and mode
specification.
For this example, a Tower distillation column with 10 stages, total condenser, and
reboiler was used to separate the mixture. The feed enters at tray 10. A reflux ratio of 5
was set as the condenser mode specification, and a mole fraction of 0.0001 of benzene
in the bottom was set as the reboiler mode specification.
With these specifications, the overhead purity does not reach the 99.9 mole % target. By
specifying component mole fraction of benzene (=0.999) instead of reflux ratio, we allow
the reflux ratio to vary until the mass balance is achieved. The calculated reflux ratio
turns out to be 19.16.
This reflux ratio is quite large. It can be decreased by increasing the number of stages
(e.g., 30 stages) and/or relocating the feed tray. Specifying N = 30 and feed tray = 15
gives a reflux ratio of 2.3.
22
Once the benzene has been separated, a second column is needed to separate toluene
from o-xylene. The procedure is the same as for the first column. The condenser mode
specification is set at 0.999 mole fraction of toluene in the distillate, while the reboiler
mode specification is set at 0.999 mole fraction of o-xylene. Using 20 stages and feeding
the bottoms of the first column to the second column at tray 10 results in the desired
separation, with a reflux ratio of 5.4 for UnitOp 4. Specifying N = 30 and feed tray = 15
lowers the reflux ratio to 1.8, and gives 99.9 mole % products.
To obtain a summary of results for the column(s), click the Reports drop-down (Home
tab, Results group) and then under the UnitOp heading, click Select. For tabulated
results, right-click the UnitOp and select View Column Profile. Select Plot Column
Profile from the right-click menu to generate charts for the temperature profile, total
vapor flow, and/or total liquid flow.
Note: In the Tower specification dialog, under the Convergence tab, notice that the
mode 6 (Auto Estimation) is used. This means that CHEMCAD will try its best to make
the column converge. In the case that the mode specifications are unfeasible, the UnitOp
ID will turn yellow and CHEMCAD will issue a warning: "Can't converge with original
specs. Alternative optimal solution is found."
23
Column Performance: Benzene/Toluene
50 % vaporized feed
24
Then, the effect of changing a parameter or specification is investigated. This activity can
be carried out automatically using the Sensitivity Analysis feature. To learn more, press
[F1] to open the CHEMCAD help file, then see the help topic called "Sensitivity Analysis."
You can also see the example called _Process Simulation Essentials\9 Tools\3 -
Sensitivity analysis - distillation.
As a sample, a sensitivity analysis named "FeedLoc" has been conducted. It records the
mole fraction of benzene in the distillate as the feed location is changed from N = 2 to N
= 9 in equal steps.
The sensitivity analysis tools are found on the Analysis tab, in the Sensitivity group.
Using the Select Sensitivity Analysis drop-down, select FeedLoc, then click Run All.
To review the input for the analysis, return to the Sensitivity group (FeedLoc should still
be selected) and click Edit Sensitivity Analysis.
To review the results, return to the Sensitivity group and click Report Results. The
Sensitivity Analysis Report indicates the optimum feed location to be tray 5.
Note: The sensitivity analysis enables you to test multiple cases efficiently, but it does
not provide you the optimum answer.
The "alternative case" achieves the specified separation while maximizing recovery and
minimizing reflux ratio.
With this example, you can experiment with the specifications and compare the results
to the base case. By doing this, you can identify trends and design an optimization
strategy.
Finding the optimum usually involves the interplay of many parameters and
specifications, as well as economic considerations. Column design is often a trial-and-
error process.
The alternative design achieves 95% purity and 90% recovery of benzene in the
distillate. The feed conditions and pressure drop were not changed with respect to the
base case. The number of stages and feed location were adjusted to maintain the reflux
ratio below 3.
To obtain a summary of results for the column(s), click the Reports drop-down (Home
tab, Results group) and then under the UnitOp heading, click Select. For tabulated
results, right-click the UnitOp and select View Column Profile. Select Plot Column
Profile from the right-click menu to generate charts for the temperature profile, total
vapor flow, and/or total liquid flow.
25
Absorption and Stripping
This example shows the configuration and performance of an absorption column (UnitOp
1) and a stripping column (UnitOp 2). Propane is the key component in both cases--that
is, the component which is transferred from one phase to the other, with nitrogen mostly
in the vapor phase and decane in the liquid phase.
Absorption column:
The absorbent (i.e., liquid) is fed at the top of the column and the mixture containing the
key component is fed at the bottom. The streams flow countercurrently and propane is
absorbed into the liquid phase.
The stripping agent (i.e., gas) is fed at the bottom of the column and the mixture
containing the key component is fed at the top. The streams flow countercurrently and
propane is transferred to the vapor phase.
26
Key variables:
The component separation depends on the number of stages and the ratio of liquid-to-
vapor feed rates. The identity of the absorbent or stripper also affects the performance.
Note: Streams 2 and 6 should always enter the bottom of the column, so change the
feed stage to be the same as the number of stages.
What if you increase or decrease the flow rate of decane (1) or nitrogen (2)?
What if you use dodecane (i.e., a heavier liquid) as the absorbent instead?
Next, this example shows an absorption column followed by a desorption column (a.k.a.
regenerator). First, propane is recovered by absorption using decane. Then, decane is
regenerated (i.e., recovered and recycled back to the absorption column) in the
desorption column. This arrangement is typical of processes involving the absorption of
impurities feeding the heavy solvent at stage 1 and the regeneration of such solvent in a
desorption/regeneration step. Typical processes include gas sweetening and gas
dehydration.
For relevant examples, see the see the examples in the Gas Processing folder.
To review the column results, first right-click the UnitOp to bring up the UnitOp menu.
Click Plot Column Profile or View Column Profile to see the data in chart or tabular
format.
27
Liquid-liquid Extraction
The solvent (water) and the feed are two essentially immiscible liquids. The solute
(acetone), to be extracted from benzene by water, is soluble in both phases.
On the Home tab, in the Results group, click the Charts drop-down. Under the
Thermodynamic heading, choose Binary LLE, then select any combination of two
components (acetone-benzene, acetone-water, or water-benzene).
Two key design variables are 1) number of trays and 2) water flow rate. This example
shows the optimized design, but you can still modify the number of trays, feed location,
and water flow rate to see the effects in the separation.
NRTL was selected as the K-value because it serves to model the non-ideal behavior in
the liquid phase.
28
Ethyl Acetate by Reactive Distillation
In reactive distillation, phase equilibrium and chemical reaction occur in the same
equipment. Phase separation is controlled by phase equilibrium relations or rate-based
mass and heat transfer mechanisms (i.e., packed columns); chemical reactions are
controlled by chemical equilibrium relations or by reaction kinetics. The reaction takes
place in the liquid phase.
Kinetic data for the forward and backward reaction were entered into the column.
Double-click on the column (1) to open the SCDS Distillation Column dialog box. Notice
that Check here for reactive distillation is checked. Click OK to open the Reactive
Distillation Data menu, then click on the options to review the input data.
NRTL binary interaction parameters (BIPs) are used to account for this
thermodynamically complex system with two liquid phases and vapor phase association.
To review BIPs, click the Reports drop-down (Home tab, Results group), then under
the Flowsheet heading, choose Thermodynamics.
To review the K-value and vapor phase association selections, click Thermodynamic
Settings (Home tab, Setup group).
29
Reactor Models in CHEMCAD
This example shows an esterification reaction between acetic acid and ethanol to
produce ethyl acetate and water using all of CHEMCAD's reactor models, with the
exception of the vessel reactor, which involves dynamics. The reaction takes place in the
liquid phase and the NRTL K-value has been chosen to model the non-ideal behavior of
the mixture.
For both the equilibrium reactor and the Gibbs reactor, the reaction stoichiometry for the
forward reaction has been entered.
Note: The Gibbs reactor is not well suited to liquid-phase reactions. It is shown in this
example to illustrate its setup.
For both the continuous stirred-tank reactor (CSTR) and the plug flow reactor (PFR), the
reaction stoichiometry and kinetic data (frequency factor and activation energy) have
been entered for both the forward and reverse reactions.
For the stoichiometric reactor, the reaction stoichiometry and fractional conversion of
ethanol have been specified.
All reactor UnitOps operate isothermally at 50 °C. You may choose Adiabatic as the
thermal mode when specifying the reactor.
Exercises:
To learn more about each model, open the relevant specification dialog box, then press
[F1] to open the appropriate topic in the CHEMCAD help file.
30
EREA Shift and Methanation Reactors:
Comparison Between A+B/T and Special Methods in CHEMCAD
This simulation compares the resulting equilibrium conversion when changes are made
to the feed composition and conditions.
Two of the most common reactions will be evaluated using the Equilibrium Reactor
model. Both the water-gas-shift and the methanation reactions occur in the vapor phase.
For these reactions, CHEMCAD has built-in parameters. You can select either the Shift
reactor or Methanation reactor option in the Reactor Model area of the Equilibrium
Reactor dialog box.
After you select an option, all the required equilibrium data and stoichiometry for the
reaction(s) are stored within the program. These reactions are assumed to take place in
the vapor phase.
This example shows how to enter the required data into a general equilibrium reactor
(first row) and how to specify the reactor type instead (second row).
The entered equilibrium data is the same that CHEMCAD uses for the shift and
methanation reactor. To learn more, press [F1] to open the CHEMCAD help file, then see
the help topic called "Equilibrium Reactor (EREA)."
31
Methanation:
A= -29.3014
B= 26248.4
A= -4.45469
B= 4593.17
Temperature: Kelvin
Pressure: Atm
32
Equilibrium Reactor (EREA)
This simulation compares the resulting equilibrium conversion when changes are made
to the feed composition and conditions.
Two of the most common reactions will be evaluated using the Equilibrium Reactor
model. Both the water-gas-shift and the methanation reactions occur in the vapor phase.
For these reactions, CHEMCAD has built-in parameters. You can select either the Shift
reactor or Methanation reactor option in the Reactor Model area of the Equilibrium
Reactor dialog box.
After you select an option, all the required equilibrium data and stoichiometry for the
reaction(s) are stored within the program. These reactions are assumed to take place in
the vapor phase.
Note: This example is set for the shift reaction only. To simulate the methanation
reactor, include some water in the feed. Also, change the reactor type and change the
number of reactions to 2 (both the methanation and water-gas-shift reactions occur
here; thus simulation is a multi-reaction equilibria problem).
All reactor UnitOps operate isothermally at 826.85 °C. You may choose Adiabatic as the
thermal mode when specifying the reactor.
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 483-504, Example 13.5 (modified).
33
Kinetic Reactor (KREA)
This example shows an esterification reaction between acetic acid and ethanol to
produce ethyl acetate and water using the Kinetic Reactor model. The reaction takes
place in the liquid phase. The NRTL K-value has been chosen to model the non-ideal
behavior of the mixture.
For this example, the plug flow reactor was chosen as the reactor type. You may switch
to a continuous stirred-tank reactor by selecting the option in the Kinetic Reactor dialog
box.
The first row shows the difference between the thermal modes. In adiabatic mode, no
heat transfer occurs between the reactor and the surroundings. Since this reaction is
exothermic, the temperature of the mixture increases, thus vaporizing the mixture. In
isothermal mode, the temperature is held constant by adding or withdrawing heat from
the reactor. Given the nature of the reaction, heat is removed here.
The second row shows two common ways of improving the yield when using kinetic
reactors. Reactor 3 has twice the volume and reactor 4 operates at a higher temperature
(70 °C).
34
Kinetics of the forward and reverse reactions are considered. The reaction stoichiometry
and kinetic data (frequency factor and activation energy) have been entered for each
reaction.
Review the units for the kinetic expression on the More Specifications tab in the
Reactor dialog box.
To learn more about the Kinetic Reactor model, press [F1] to open the CHEMCAD help
file, then see the help topic called "Kinetic Reactor (KREA)."
35
Heat Exchangers: Principles and Applications
Heat transfer occurs from a warmer fluid to a cooler fluid through a solid wall separating
the two. Heat transfer may be sensible heat--that is, the temperature rises or falls
without any phase change--or latent heat, involving a phase change such as
condensation or vaporization.
This example focuses on heat exchangers and simple fired heater models.
After running the UnitOp, it is useful to plot heat curves for the process stream (and
utility stream, if any). First click any heat exchanger to select it. Then on the Home tab,
in the Results group, click the Charts drop-down and choose Heat Curves under the
UnitOp heading. Select either chart axis option. The first option, temperature vs deltaH,
plots temperature as a function of heat duty. The second option, temperature vs %
length, plots temperature as a function of the % length of the heat exchanger area.
Note: For countercurrent heat exchangers, streams enter the unit from opposite sides.
Sensible heat is transferred: the fluid is cooled or heated without inducing a phase
change. Plot the heat curve and notice the slope of the curve.
Plot the heat curve and notice how the slope flattens as soon as the phase change
begins.
36
c) Fired Heater: Specify outlet temperature. CHEMCAD calculates the heat required and
fuel usage to achieve the change in temperature. This UnitOp is used to heat a large
amount of material before it enters the process. Optional specifications include the
pressure drop and thermal efficiency (default = 75%). The rated heat duty and fuel
heating value are specified when a particular fired heater is rated.
d) Without phase change: The process stream is heated or cooled by using a warmer or
colder fluid, respectively. Specify outlet temperature for either stream. CHEMCAD
calculates the heat duty (only the positive heat duty is reported) and LMTD. Review the
specifications and the heat curves. Plot the heat curves and notice how the slope
continuously increases/decreases for one fluid while the other fluid exhibits the opposite
trend.
e) With phase change: The process stream is heated or cooled by using a warmer or
colder fluid, respectively. Specify outlet temperature for either stream. CHEMCAD
calculates the heat duty (only the positive heat duty is reported) and LMTD. Plot the heat
curves and notice how the slope flattens during the phase change.
Note: In practice, heat exchangers exhibit a pressure drop. Its magnitude depends on
the size of the heat exchanger, as well as the flow rates and temperature change for the
streams exchanging heat.
Note: All UnitOps use simulation mode 0 Enter specifications (CHEMCAD simulation).
With this mode, outlet conditions are calculated based on thermal specifications (e.g.,
outlet temperature, vapor fraction, heat duty). Ideal heat transfer is calculated according
to Q = U*A*LMTD. U is not calculated rigorously. To use any of the other terms, you
need to have a CC-THERM license.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Simple Heat Exchanger" and "Two-sided Heat Exchanger."
37
Heat Exchangers: Use Cases
Heat transfer occurs from a warmer fluid to a cooler fluid through a solid wall separating
the two. Heat transfer may be sensible heat--that is, the temperature rises or falls
without any phase change--or latent heat, involving a phase change such as
condensation or vaporization.
This example demonstrates the use of the two-sided heat exchanger. For all cases,
steam at 300 °F is the utility stream.
Notice the outlet temperature for the utility in all cases. What do you observe?
After running the UnitOp, it is useful to plot heat curves for the process and utility
streams. First click any heat exchanger to select it. Then on the Home tab, in the
Results group, click the Charts drop-down and choose Heat Curves under the UnitOp
heading.
38
Select either chart axis option. The first option, Plot X-axis = DelH, plots temperature as
a function of heat duty. The second option, Plot X-axis = % Length, plots temperature as
a function of the % length of the heat exchanger area.
Note: For countercurrent heat exchangers, as in this example, streams enter the unit
from opposite sides.
Notice the slope for each fluid in the heat curve. Is the slope the same? Does the slope
change at any point?
Note: Heat exchangers on this flowsheet use simulation mode 0 Enter specifications
(CHEMCAD simulation). With this mode, outlet conditions are calculated based on
thermal specifications (e.g., outlet temperature, vapor fraction, heat duty). Ideal heat
transfer is calculated according to Q = U*A*LMTD. U is not calculated rigorously. To
calculate U rigorously from geometry, you need to have a CC-THERM license.
All cases with the exception of case 9 have the utility option turned off. When the utility
option is activated (UnitOp 9), CHEMCAD adjusts the flow rate of an input stream, in this
case the utility, to match the required duty (calculated) of the unit. Using this option
requires two specifications (e.g., outlet temperature for each stream), instead of only
one as in cases 1-8.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Simple Heat Exchanger" and "Two-sided Heat Exchanger."
39
Heat Exchangers: Equipment Design, Sizing, and Costing
After running the UnitOp, it is useful to plot heat curves for the process and utility
streams. First click any heat exchanger to select it. Then on the Home tab, in the
Results group, click the Charts drop-down and choose Heat Curves under the UnitOp
heading.
Select either chart axis option. The first option, Plot X-axis = DelH, plots temperature as
a function of heat duty. The second option, Plot X-axis = % Length, plots temperature as
a function of the % length of the heat exchanger area.
Note: For countercurrent heat exchangers, as in this example, streams enter the unit
from opposite sides.
Notice the slope for each fluid in the heat curve. Is the slope the same? Does the slope
change at any point?
This example shows the various simulation modes for a two-sided heat exchanger.
(1) T for stream 2 and vapor fraction for stream 4 specified, as well as the pressure drop
for both streams. Area (per shell) is specified, thus the heat transfer coefficient U is
calculated. With the selected utility option, CHEMCAD calculates the utility flow rate
(stream 3).
40
(2) Stream 7 is specified with the same steam flow rate as stream 3. The heat transfer
coefficient U is specified (but different from the one calculated for UnitOp 1), thus the
area (per shell) is calculated.
(3) Both U and area (per shell) are specified. This counts as a single thermal
specification and the dialog box is complete. The outlet temperatures are calculated for
both streams.
(4) Cocurrent has been selected as the exchanger type in the Misc. Settings tab.
Countercurrent is most common due to its higher efficiency. You can change the flow
rate of water to 9000 kg/h, run the UnitOp, and then plot the heat curves to appreciate
the difference.
(5) Additional specifications can be entered under the Cost Estimations tab. The option
to run the costing report has been checked for this UnitOp.
Click UnitOp 6 to select it, then on the Sizing tab, in the Heat Exchanger group, click
Shell and Tube to bring up the Shell and Tube Exchanger menu. For this example, no
specifications have been entered in the tabs, so the default settings and values are used
for the calculation. Click General Specifications and change the Calculation Mode
setting to Design.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Two-sided Heat Exchanger" and "Shell and Tube Overview."
41
Heat Exchangers: CC-THERM Modes
This example shows the various simulation modes for a two-sided heat exchanger.
(1) T for stream 2 and vapor fraction for stream 4 specified, as well as the pressure drop
for both streams. Area (per shell) is specified, thus the heat transfer coefficient U is
calculated. With the selected utility option, CHEMCAD calculates the utility flow rate
(stream 3).
(2) Same flow rate as stream 3 is specified for stream 7. The heat transfer coefficient U
is specified (but different than the one calculated for UnitOp 1), thus the area (per shell)
is calculated.
(3) Both U and area (per shell) are specified. This counts as a single thermal
specification and the dialog box is complete. The outlet temperatures are calculated for
both streams.
(4) Rating mode shows us "Can our exchanger give us flowsheet performance?"
Click UnitOp 4 to select it, then on the Sizing tab, in the Heat Exchanger group, click
Shell and Tube. In the Shell and Tube Exchanger menu, select General Specifications
and set Calculation mode to Rating.
For CC-THERM:
Effective Area is "How much area does this unit have for heat transfer?"
42
Area required is "How much area does the unit require to perform the specified heat
transfer?"
Ucalc is calculated from Q=U*A*LMTD using required area, outlet temperatures, and
overall duty.
Uservice represents the heat transfer that would occur if you observe this unit
performing as specified.
Uservice is calculated from Q=U*A*LMTD using effective area, outlet temperatures, and
heat specification for the unit.
In general, if Ucalc < Uservice, the exchanger is not capable of performing the desired
heat transfer.
(6) Shell & tube simulation mode lets you answer the question: "What would happen if
these feeds went through this exchanger?"
(7) Shell & tube fouling factor rating lets you change the fouling until the predicted
temperatures out match reality.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Two-sided Heat Exchanger" and "Shell and Tube Overview."
43
Recycle: Closing the Loop
CHEMCAD can automatically handle recycle problems by determining recycle cut streams
and unit operation calculation sequence.
On the Home tab, in the Setup group, click Convergence to review the default settings
and/or make changes. Smart Cut allows for faster convergence, but you can choose
Normal recycles if you prefer.
You can override this and specify your own cut streams by going to the Specification
tab and clicking Select from the Cut Streams group. You need to make sure that they
cut the recycle loops completely.
44
Nested Recycle: Closing the Inner Loop
CHEMCAD can automatically handle recycle problems by determining recycle cut streams
and unit operation calculation sequence.
On the Home tab, in the Setup group, click Convergence to review the default settings
and/or make changes. Smart Cut allows for faster convergence, but you can choose
Normal recycles if you prefer.
You can override this and specify your own cut streams by going to the Specification
tab and clicking Select from the Cut Streams group. You need to make sure that they
cut the recycle loops completely.
45
Nested Recycle: Closing the Outer Loop
CHEMCAD can automatically handle recycle problems by determining recycle cut streams
and unit operation calculation sequence.
On the Home tab, in the Setup group, click Convergence to review the default settings
and/or make changes. Smart Cut allows for faster convergence, but you can choose
Normal recycles if you prefer.
You can override this and specify your own cut streams by going to the Specification
tab and clicking Select from the Cut Streams group. You need to make sure that they
cut the recycle loops completely.
46
Flow Models: Input Specifications
This example shows the equipment used to change the pressure of fluids in a process.
Pumps increase the pressure of a liquid stream. When you specify discharge pressure or
pressure increase, CHEMCAD calculates the required work. If efficiency is not specified,
ideal work is calculated (efficiency = 1). Notice how lower efficiency causes the
temperature of the liquid to increase. This is because the additional work (compared to
the ideal) goes into the fluid. Pumping liquid is cheap, and the properties of the fluid are
not changed by much. If there is vapor inside the pump, CHEMCAD will issue a warning
and the pump ID will turn yellow.
Valves decrease the pressure of a fluid, either liquid, vapor, or saturated mixture. The
valve performs an adiabatic flash calculation on the inlet stream at output pressure. The
Joule-Thomson effect describes the temperature change of a fluid as it expands through
the valve. The change in enthalpy is zero and no work is produced. Notice the outlet
temperature of the streams.
Expanders perform the opposite operation by expanding the gas, lowering its
temperature, and generating power as a result.
47
Using the Specify performance curves mode for either the pump or the
compressor/expander allows you to enter the performance curve for the equipment.
Specify performance curve is selected as the UnitOp mode, the speed lines and pump
speed specified, and the curve data entered on the appropriate column of the matrix that
appears when you click OK.
Two calculation options: 1) Fixed flow rate, calculate Pout (used in this example)
calculates the outlet pressure considering the inlet flow rate and the performance curve
data; 2) Pout from downstream uop, calc flow rate requires a downstream unit operation
such as a Node UnitOp (see the "Pressure loop - pump performance curve" example).
CHEMCAD then calculates the flow rate passing through the pump. This is used to
perform hydraulic balance on piping systems.
Equipment costing: On the Cost Estimation tab of the UnitOp dialog box, you can
enter additional specifications, then click Run the costing report after calculating unit.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics for
the Compressor/Expander, Liquid Pump, and Valve UnitOps, found under UnitOps and
Other Flowsheet Objects > UnitOps > Piping and Flow.
48
Single-branch Piping Configurations
Inlet flow rate and pump outlet pressure are known. CHEMCAD calculates pressure drop
throughout the single branch, resulting in an outlet pressure of 20.81 psia.
The controller varies the output pressure of the pump until the pressure at the outlet is
exactly 20 psia.
49
Add Nodes – Simultaneously Solve for Flow Rate:
Heat exchangers do not scale (change) flow rate to balance pressure drop. For this
reason, the heat exchanger does not need its own nodes.
Nodes are used to measure pressure and hydraulic balances between unit operations on
the flowsheet.
In this example, the pressure at the outlet is known (20 psia), and the inlet flow rate is
calculated as a function of pressure.
To enter the performance curve in the pump dialog box, select Specify performance
curve as the pump mode.
50
Reports: Benzene/Toluene/Xylene Distillation
The purpose of this example is to show the reports that CHEMCAD generates and how to
access them. Follow the instructions below to generate individual reports.
To choose how to display reports, use the Report Viewer drop-down in the Results
group of the Home tab. Change the default report viewer by choosing among
CHEMCAD's internal report viewer, MS Word, MS Excel, and others.
Stream-based reports:
To select the active property set, use the Property Set drop-down in the Results group
of the Home tab. Choose among Quickview, Stream Composition, and Stream Property.
To customize the selected property set, click the gear icon located below the Property
Set drop-down. Then in the Property Set Preferences dialog, use the Properties tab on
the right to choose the stream properties that appear on the report. Click the Help
button to learn more.
51
On the Home tab, in the Results group, click the Reports drop-down. Under the
Stream heading, choose either Select (type in the stream IDs one per line or click on
the streams), All Streams, Feed, Product, or UnitOp (inlet and outlet streams for a
specified UnitOp).
UnitOp-based reports:
On the Home tab, in the Results group, click the Reports drop-down. Under the
UnitOp heading, choose:
1) Select to view UnitOp results. Enter the UnitOp IDs one per line or click on the
UnitOp symbols.
2) Spec Sheet to export detailed information into a pre-formatted Excel worksheet (one
per piece of equipment). This is useful for soliciting a manufacturing quote, for example.
Distillation reports:
On the Home tab, in the Results group, click the Reports drop-down. Under the
Distillation heading, choose either:
2) Tray Composition to list vapor and liquid flow rate, and K-value of each component
on each stage.
3) Tray Properties to list properties such as density, viscosity, and thermal conductivity
for each stage.
Flowsheet-based reports:
On the Home tab, in the Results group, click the Reports drop-down. Under the
Flowsheet heading, choose:
3) Mass and Energy to view mass and energy balances as well as information about
the calculation mode used, convergence, recycle loops, and cut streams, if any.
You can also customize a combination of individual reports. On the Home tab, in the
Results group, click the Reports drop-down. Click Report Writer near the bottom and
choose Consolidated, then select the sections of interest and generate the report.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Output and Reports."
52
Charts: Phase Equilibria
The purpose of this example is to show the charts that CHEMCAD generates and how to
access them.
Note: Charts marked with an asterisk are not available using this example. The feed
streams and Flash UnitOps have been specified to provide representative examples.
Review the specifications and resulting product streams. To learn more, see the
examples in the Phase Equilibria folder.
On the Home tab, in the Results group, click the Charts drop-down. Under the
Thermodynamic heading, choose:
1) TPXY to generate TXY, PXY, and XY diagrams. Specify binary mixture and either
constant temperature or constant pressure. It’s most common to select the more volatile
component first.
2) Binary LLE to generate liquid-liquid equilibrium curves between any two components.
An activity coefficient method should be selected as the K-value model and
53
Vapor/Liquid/Liquid/Solid should be selected as the Global Phase Option in the
Thermodynamic Settings dialog (Home tab, Setup group).
3) Binary SLE to generate solid-liquid equilibrium curves between any two components.
Vapor/Liquid/Liquid/Solid should be selected as the Global Phase Option in the
Thermodynamic Settings dialog (Home tab, Setup group).
4) Binodal to generate a ternary phase diagram that shows the component distribution
in the two liquid phases. Enter the ternary mixture and temperature.
5) Residue Curves to display distillation zones, azeotropes, and residue curves. Specify
ternary mixture and pressure.
6) Binodal/Residue Curves to combine the curves from a binodal chart and residue
curve chart. This is useful for heterogeneous azeotropic distillation. The order in which
you select the components determines the edges of the equilateral triangle chart.
Note: The first component becomes the left edge, the second component the right edge,
and the third component the base.
Note: For the Binodal chart to be generated, the first and third components should form
two liquid phases.
Click any stream to select it. Then on the Home tab, in the Results group, click the
Charts drop-down. Under the Stream heading, choose:
1) Stream Properties to plot one selected stream property (e.g., vapor pressure,
density, viscosity) as a function of temperature. Specify the temperature range, then
click OK.
2) Phase Envelopes to plot a phase envelope. The text report includes tabulated data
and Tc, Pc, Zc values for the mixture. The critical point of the mixture is indicated.
Results at vapor fractions other than 0 and 1 can be included.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Output and Reports."
54
Charts: Benzene/Toluene Distillation
In this example, a mixture of benzene and toluene is separated by distillation. The Tower
distillation model was used to perform rigorous calculations. The two columns shown
have different specifications and performance.
To learn how to build this example, see the example called _Process Simulation
Essentials\3 Separators\4 - Distillation column performance. The purpose of this
example is to show the charts that CHEMCAD generates and how to access them.
Note: Charts marked with an asterisk are not available using this example.
On the Home tab, in the Results group, click the Charts drop-down and choose TPXY
under the Thermodynamic heading. Specify the binary mixture and either constant
temperature (or constant pressure). It’s most common to select the more volatile
component first. Then check the boxes on the right to generate PXY (or TXY) and XY
diagrams.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
LLE under the Thermodynamic heading. CHEMCAD will tell you that benzene and
toluene are miscible, and thus only one liquid phase exists.
The Binodal chart is not available because these components do not form two liquid
phases. The Residue Curves chart is not available because this is a binary mixture.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
SLE under the Thermodynamic heading. Enter the binary mixture.
55
To plot heat curves for the condenser and reboiler, first click either column to select it.
Then on the Home tab, in the Results group, click the Charts drop-down and choose
Heat Curves under the UnitOp heading.
To plot profiles for either column, first click the UnitOp to select it. Then on the Home
tab, in the Results group, click the Charts drop-down and choose Column Profiles
under the UnitOp heading.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Output and Reports." The "Graphical Reports" section of this topic addresses charts.
56
Charts: Exchangers and Plug Flow Reactor
In this example, acetic acid and ethanol react to form ethyl acetate and water according
to the reversible esterification reaction. The reaction takes place in the liquid phase, and
the NRTL K-value has been chosen to model the non-ideal behavior of the mixture.
In addition, the Plug Flow Reactor was chosen as the reactor type. The purpose of this
example is to show the charts that CHEMCAD generates and how to access them.
Note: Charts marked with an asterisk are not available using this example.
On the Home tab, in the Results group, click the Charts drop-down and choose TPXY
under the Thermodynamic heading. Specify the binary mixture and either constant
temperature (or constant pressure). It’s most common to select the more volatile
component first. Then check the boxes on the right to generate PXY (or TXY) and XY
diagrams.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
LLE under the Thermodynamic heading. CHEMCAD will tell you that acetic acid and
ethanol are miscible, and thus only one liquid phase exists.
On the Home tab, in the Results group, click the Charts drop-down and choose
Binodal/Residue Curves under the Thermodynamic heading. Enter the ternary mixture
and specify pressure.
57
Note: The Binodal chart is not available because these components do not form two
liquid phases.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
SLE under the Thermodynamic heading. Enter the binary mixture.
For both heat exchangers, the utility option is active, allowing CHEMCAD to determine
the utility flow rate provided two thermal specifications. The first heat exchanger is
specified as countercurrent, while the second is specified as cocurrent (see the Type
specification on the Heat Exchanger dialog’s Misc. Settings tab). The heat curve will
change depending on what type is selected.
To plot heat curves for either heat exchanger, first click the UnitOp to select it. Then on
the Home tab, in the Results group, click the Charts drop-down and choose Heat
Curves under the UnitOp heading. For more on heat exchangers, see the see the
examples in _Process Simulation Essentials\5 Heat Exchangers.
The Plug Flow reactor is adiabatic, so no heat transfer occurs between the reactor and
the surroundings. Since this reaction is exothermic, the temperature of the mixture
increases.
Kinetics of the forward and reverse reactions are considered. The reaction stoichiometry
and kinetic data (frequency factor and activation energy) have been entered for each
reaction.
Review the units for the kinetic expression by clicking the More Specifications tab in
the Reactor dialog box. For more on reactors, see the examples in _Process
Simulation Essentials\4 Reactors.
To look at the reactor profiles, first click UnitOp 2 to select it. Then on the Home tab, in
the Results group, click the Charts drop-down and choose Plug Flow Reactor Profile
under the UnitOp heading. Select the components and independent variable of interest.
For example, plot moles of both acetic acid (reactant) and ethyl acetate (product) vs
reactor volume (axial length), and include temperature (check the option).
To learn more about charts, press [F1] to open the CHEMCAD help file, then see the
help topic called "Output and Reports." The "Graphical Reports" section of this topic
addresses charts.
58
Tools: UnitOps
This example shows several of CHEMCAD's utility tool UnitOps, which are used in
building and running flowsheets. Familiarize yourself with basic use of CHEMCAD as
demonstrated in the earlier CHEMCAD Essentials examples before using these UnitOp
tools.
The Flash button on a stream dialog allows for a quick flash calculation. Define the
stream by specifying composition and two variables (T, P, or vapor fraction), then click
the Flash button located at the upper left corner of the Edit Streams dialog box. For
example, specify Stream 1 vapor fraction = 0.5 and P = 1 bar. Clicking Flash will show
you the temperature at this condition. Transport properties can be seen in the stream
properties report, or by hovering over the stream line with the Flowsheet Quickview
feature turned on.
In Feed-backward mode, the controller behaves as a solver routine. In this example, the
controller (2) adjusts the thermal specification inside the heater (i.e., temperature out)
until the vapor fraction of stream 3 is 50% vaporized. The controller will change the
adjusted variable and run UnitOps until stream 3 reaches the 50% vapor target, then
determine if the solution has been found.
59
To learn more, click the Help button in the Controller dialog box, or see the controller
examples in _Process Simulation Essentials\9 Tools. A separate PID controller
UnitOp is available for dynamic simulations.
This UnitOp can transfer stream information to another process stream (i.e., a feed or an
isolated stream). It should be placed downstream of the UnitOp that calculates the
information to be passed. Various modes and transfer options are available, which can
be reviewed by clicking the Help button in the Stream Reference dialog box.
For this example, the stream reference (3) passes stream information from stream 5 to
stream 7.
Node UnitOp:
Nodes are used to measure pressure and perform hydraulic balances between unit
operations on the flowsheet. They are placed upstream and downstream of pipes,
pumps, and control valves in piping systems. For this example, the nodes facilitate the
pressure drop calculation across the pipe. To see other examples where nodes are used,
go to the My Simulations directory, and in your examples subdirectory, find the Piping
folder.
60
Tools: META UnitOp
This example shows one of CHEMCAD's UnitOp tools, which is used in building and
running flowsheets. We do not recommend using this tool if you have only recently
started using CHEMCAD.
It is not unusual for multiple flowsheets to model various parts of a process. Integrated
flowsheets may be too large and complicated to handle. In addition, these flowsheets
may have different components and thermodynamics. The subflowsheet unit operation
(META UnitOp) sends stream data to a second flowsheet (child simulation), runs it, and
returns data to the parent flowsheet.
This example sends data to a simulation called "2.2 - META unit - child simulation",
stored in the same location as this simulation.
The META UnitOp requires the specification of inlet and outlet streams for both the
parent and child simulations, as well as the path for the child simulation, which you can
generate by browsing for the file of interest.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Subflowsheet Unit Operation (META)."
Note: The META UnitOp can only run using the sequential modular calculation sequence.
61
Tools: Child Simulation for META UnitOp
The purpose of this flowsheet is to serve as the child simulation for the simulation called
"2.1 - META unit - parent simulation", stored in the same location as this simulation.
The META UnitOp defines the feed stream (stream 1), runs this simulation, and sends
the product stream (stream 3) back to the parent flowsheet.
62
Tools: Sensitivity Analysis
In this example, a mixture of benzene and toluene is separated by distillation. The Tower
distillation model is used to perform rigorous calculations. The goal is to obtain the
highest benzene purity and recovery in the distillate.
To review the column results, first right-click Tower 4 to bring up the UnitOp menu. Click
Plot Column Profile or View Column Profile to see the data in chart or tabular
format.
63
The next step is to investigate the effect of changing a parameter or specification. This
activity can be carried out automatically using the Sensitivity Analysis feature. Sensitivity
analyses help us investigate the best parameters for a column that has 20 stages.
Note: This tool enables you to test multiple cases efficiently, but it does not give you the
optimum answer. However, the reports and charts can help you decide the best
operation based on design specifications, operational constraints, or economics.
This simulation includes three sensitivity analyses, designed to find the best operating
parameters for the column. To view the analyses, first click the Analysis tab, then select
an item from the Sensitivity group drop-down.
The analysis named "FeedLoc" varies the feed stage location from stage 2 to stage 19. It
records the mole fraction and mole rate of benzene in the distillate.
The analysis named "Reflux" varies the reflux ratio specification from 1 to 15. It records
the condenser and reboiler duties, as well as the mole fraction and mole rate of benzene
in the distillate.
The analysis named "2variables" varies the column pressure drop from from 0 to 5 bar
and the bottoms mole flow rate from 10 to 70 kmol/h. It records the bottoms
temperature, as well as the mole fraction and mole rate of benzene in the distillate.
Note: Each independent variable is treated separately. This tool cannot find correlations
between the parameters. It sets the bottom flow rate at 10 kmol/h and varies the
pressure drop. Then it changes to 20 kmol/h and repeats for each value of pressure
drop.
To review or modify the settings for the selected analysis, click Edit Sensitivity
Analysis. Click OK to close this dialog.
To run the selected analysis, click Run All. Upon completion, click Plot Results or
Report Results to see the data in chart or tabular format.
64
Controller: Simple Applications
The Controller UnitOp behaves as a solver routine. The feed-backward mode, shown in
this example, adjusts one variable (from an equipment or a stream) until the measured
variable equals the setpoint. Scaling is allowed. The setpoint can be an algebraic
calculation of two measurements.
In other words, the controller compares the measured variable to a setpoint and decides
a new value for the adjusted variable until the specified condition is achieved.
Adjust this variable: Specify UnitOp or stream ID, the adjusted variable and its unit,
and the lower and upper bounds (do not enter if you are not sure).
Until this: Specify UnitOp or stream ID, the specification variable, and any scaling or
arithmetic operation (optional).
Note: By default, CHEMCAD's default units are used (i.e., 0 Internal unit). If any options
are selected, the flowsheet global units are used for this constant.
To learn more, click the Help button located at the bottom left corner of the Controller
dialog box.
For more on CHEMCAD's default units, see the help topic called "Neutral File Import of
Component Properties." Under the Dimensional Data section, see the first line for each
table of units.
65
Controller: Refrigeration Cycle
This example shows a simple refrigeration cycle and the use of CHEMCAD's Flash
command and Controller UnitOp.
The goal is to cool 90,000 kg/h of process water from 27 °C to 12 °C. Water is used as
the refrigerant.
The isolated stream is used to perform a quick flash calculation to get the temperature
estimates. Specify amount, composition, pressure, and vapor fraction for the stream,
then click the Flash button in the upper left corner of the Edit Stream dialog, to calculate
temperature and enthalpy.
66
Guess an amount of refrigerant and specify P = 1 kPa and vapor fraction = 0 to get the
saturation temperature.
Stream 3: Saturated water flashes through a valve, which reduces the pressure back to
1 kPa.
The water that needs to be cooled down also passes through the evaporator, thus
exchanging heat with the refrigerant.
The cycle is closed when streams 1 and 5 have the same properties.
Note: The amount of process water is known, as well as its required outlet temperature.
The amount of refrigerant, however, is unknown.
For this example, a guess of 1,000 kg/h of refrigerant was used to run the simulation. To
have the same properties in streams 1 and 5, the temperature of stream 5 was specified
to be 7 °C in the heat exchanger. Because the temperature of the refrigerant is
specified, the temperature of the process water is allowed to vary. Here the specification
is not met when a mass flow rate of 1,000 kg/h is used.
Instead of guessing the mass flow rate of refrigerant, a feed-backward controller is used.
The controller "looks" at the temperature of stream 15 and manipulates the mass flow
rate in stream 9 until the temperature of stream 15 is effectively 12 °C. Once the
controller converges, the mass flow rate of refrigerant that results in an outlet
temperature of 12 °C for the process water is replaced in the feed stream specification
dialog box.
Note: this example is actually a closed cycle. However, closing the loop requires streams
9 and 13 to be very close beforehand. DO NOT attempt to draw a flowsheet from scratch
with the loops closed. It is recommended to leave the flowsheet with the loop open to
avoid convergence problems or convergence to a different solution.
Reference: Example modified from Abbott, M. M. & Van Ness, H. G. (1989). Schaum's
Outline of Thermodynamics with Chemical Applications. New York, Mc-Graw-Hill, p. 311.
67
Controller: Separators
The Controller UnitOp behaves as a solver routine. The feed-backward mode, shown in
this example, adjusts one variable (from an equipment or a stream) until the measured
variable equals the setpoint. Scaling is allowed. The setpoint can be an algebraic
calculation of two measurements.
In other words, the controller compares the measured variable to a setpoint and decides
a new value for the adjusted variable until the specified condition is achieved.
Adjust this variable: Specify UnitOp or stream ID, the adjusted variable and its unit,
and the lower and upper bounds (do not enter if you are not sure).
Until this: Specify UnitOp or stream ID, the specification variable, and any scaling or
arithmetic operation (optional).
Note: By default, CHEMCAD's default units are used (i.e., 0 Internal unit). If any options
are selected, the flowsheet global units are used for this constant.
68
To learn more, click the Help button located at the bottom left corner of the Controller
dialog box.
For more on CHEMCAD's default units, see the help topic called "Neutral File Import of
Component Properties." Under the Dimensional Data section, see the first line for each
table of units.
69
CHEMCAD Version 7
User Guide
All material © 2016 Chemstations, Inc.
CHEMCAD Version 7 User Guide
Table of Contents
Chapter 1 – Introduction to CHEMCAD ............................................................................................... 1
Overview of CHEMCAD and Its Uses ................................................................................................ 1
CHEMCAD Products and Features ................................................................................................. 3
CC-STEADY STATE ....................................................................................................................................... 3
CC-DYNAMICS ............................................................................................................................................... 3
CC-BATCH ....................................................................................................................................................... 3
CC-THERM....................................................................................................................................................... 3
CC-SAFETY NET ............................................................................................................................................. 3
CC-FLASH ........................................................................................................................................................ 3
CHEMCAD Features by Module ...................................................................................................... 4
UnitOps by Module ............................................................................................................................ 5
Chapter 2 – Getting Started with CHEMCAD ..................................................................................... 7
Creating a User Support Center Account ........................................................................................... 7
Downloading the Software ................................................................................................................... 9
Installing the software ........................................................................................................................... 9
Licensing CHEMCAD ......................................................................................................................... 12
Types of CHEMCAD Licenses ........................................................................................................ 12
License Settings ................................................................................................................................. 12
Updating a License ........................................................................................................................... 14
Getting Help with CHEMCAD .......................................................................................................... 17
Online Help ....................................................................................................................................... 17
The Chemstations Website .............................................................................................................. 17
Contacting Chemstations Technical Support ............................................................................... 17
CHEMCAD Version 7 User Guide i
Chapter 3 – The CHEMCAD Interface ................................................................................................ 19
The CHEMCAD Window ................................................................................................................... 19
The Workspace .................................................................................................................................. 19
The CHEMCAD Explorer Pane ...................................................................................................... 20
The Recent Files Tab ....................................................................................................................................... 21
The Simulation Tab ......................................................................................................................................... 21
The Visual Basic Tab....................................................................................................................................... 22
The Palette Pane ................................................................................................................................ 22
Selecting a Palette ............................................................................................................................................ 23
Changing the Color Scheme of an Existing Palette ......................................................................................... 23
Changing the Order of UnitOp Icons in a Palette ............................................................................................ 24
Removing UnitOp Symbols from a Palette ..................................................................................................... 24
Creating a Custom Palette ............................................................................................................................... 24
Copying an Existing Palette............................................................................................................................. 25
Renaming a Palette .......................................................................................................................................... 25
Using a Custom Color Scheme to Change UnitOp Symbol Colors ................................................................. 25
Resetting All Built-in Palettes to Default Configuration ................................................................................. 26
The Messages Pane ........................................................................................................................... 26
The Errors and Warnings Tab .......................................................................................................................... 26
The Run Trace Tab .......................................................................................................................................... 26
The Notes Tab ................................................................................................................................................. 27
The Main Menu ................................................................................................................................. 27
The Toolbar ........................................................................................................................................ 27
Customizing the CHEMCAD Screen ................................................................................................. 27
Viewing and Hiding Screen Elements ........................................................................................... 28
Resizing and Moving Items ............................................................................................................. 28
Resizing a Pane ................................................................................................................................................ 28
Moving a Pane ................................................................................................................................................. 29
Pinning and Unpinning Panes ........................................................................................................ 29
Flowsheet Drawing Tools ................................................................................................................... 31
The Flowsheet toolbar ...................................................................................................................... 31
The Arrange toolbar ......................................................................................................................... 32
The Lock toolbar ............................................................................................................................... 32
The Draw toolbar .............................................................................................................................. 32
The TextBox Tool ........................................................................................................................................... 33
Simple Drawing Tools: Line, Arrow Line, Ellipse, Rectangle, RoundRect .................................................... 33
The Polygon Tool ............................................................................................................................................ 33
The Align toolbar .............................................................................................................................. 34
Other Useful Interface Hints ............................................................................................................... 34
Undo and Redo ................................................................................................................................. 34
Flowsheet Quickview ....................................................................................................................... 35
ii CHEMCAD Version 7 User Guide
Introduction to CHEMCAD
Adjusting Your View of the Workspace ........................................................................................ 36
Resetting the User Interface ............................................................................................................ 36
Chapter 4 – Working with Simulation Files ...................................................................................... 37
About CHEMCAD Simulation Files .................................................................................................. 37
User Components in CHEMCAD .................................................................................................. 37
Example Files ..................................................................................................................................... 38
Opening an Existing Simulation ........................................................................................................ 38
Creating a New Simulation ................................................................................................................. 39
Saving a Simulation.............................................................................................................................. 39
Saving Different Cases for the Same Simulation .......................................................................... 40
E‐mailing a Simulation ........................................................................................................................ 41
Sending from Within CHEMCAD .................................................................................................. 41
Attaching to an E‐mail ..................................................................................................................... 41
Working with CHEMCAD Files from Previous Versions .............................................................. 42
Chapter 5 – Building and Using a Basic Simulation ........................................................................ 45
Starting a New Simulation .................................................................................................................. 45
Specifying Engineering Units ............................................................................................................. 45
Selecting Chemical Components ........................................................................................................ 46
Finding a Component ...................................................................................................................... 47
Adding a Component ....................................................................................................................... 49
Changing the Order of Selected Components .............................................................................. 49
Removing Items from the Selected Components List ................................................................. 50
Selecting K‐value and Enthalpy Options .......................................................................................... 50
Using the Thermodynamics Wizard .............................................................................................. 50
Selecting Components to Ignore ...................................................................................................................... 50
Specifying Process Conditions ........................................................................................................................ 50
How the Thermodynamics Wizard Makes Suggestions .................................................................................. 51
Should the Thermodynamics Wizard be trusted to make design decisions? ................................................... 51
Manually Selecting Thermodynamics Settings ............................................................................ 51
Drawing the Flowsheet ........................................................................................................................ 52
Adding UnitOps ............................................................................................................................... 52
Using Alternative UnitOp Symbols ................................................................................................................. 53
Manipulating UnitOp Icons ............................................................................................................................. 54
UnitOp IDs ...................................................................................................................................................... 54
UnitOp ID Ranges ........................................................................................................................................... 55
UnitOp Names ................................................................................................................................................. 55
CHEMCAD Version 7 User Guide iii
Feed and Product Arrows ............................................................................................................... 56
Drawing and Connecting Streams ................................................................................................. 56
Choosing a Stream Route ................................................................................................................................ 57
Rerouting a Stream .......................................................................................................................................... 57
Stream IDs ....................................................................................................................................................... 58
Stream ID Ranges ............................................................................................................................................ 59
Stream Names .................................................................................................................................................. 59
Stream Intersections......................................................................................................................................... 59
Defining Streams .................................................................................................................................. 60
Thermodynamic Properties ............................................................................................................. 61
Stream Composition ......................................................................................................................... 61
Total Flow Properties ....................................................................................................................... 61
Specifying Equipment Parameters ..................................................................................................... 62
Running the Simulation ....................................................................................................................... 63
Reviewing the Results .......................................................................................................................... 63
Chapter 6 – Using CHEMCAD for High‐fidelity Modeling ........................................................... 65
What is high‐fidelity modeling? ......................................................................................................... 65
Criteria for High‐fidelity Modeling ................................................................................................... 66
Introduction to Equipment Sizing ..................................................................................................... 66
High‐fidelity Modeling and Sizing for Common UnitOps ............................................................ 67
Piping .................................................................................................................................................. 67
Low-fidelity ..................................................................................................................................................... 67
Sizing ............................................................................................................................................................... 67
High-fidelity .................................................................................................................................................... 68
Pumps, Compressors, and Expanders ........................................................................................... 68
Low-fidelity ..................................................................................................................................................... 68
High-fidelity .................................................................................................................................................... 68
Vessels and Tanks ............................................................................................................................. 68
Low-fidelity ..................................................................................................................................................... 68
Sizing ............................................................................................................................................................... 69
High-fidelity .................................................................................................................................................... 69
Valves ................................................................................................................................................. 70
Low-fidelity ..................................................................................................................................................... 70
Sizing ............................................................................................................................................................... 70
High-fidelity .................................................................................................................................................... 70
Columns ............................................................................................................................................. 70
Low-fidelity ..................................................................................................................................................... 70
Sizing ............................................................................................................................................................... 71
High-fidelity .................................................................................................................................................... 72
Heat Exchangers ............................................................................................................................... 72
Low-fidelity ..................................................................................................................................................... 72
iv CHEMCAD Version 7 User Guide
Introduction to CHEMCAD
vi CHEMCAD Version 7 User Guide
Introduction to CHEMCAD
User‐specified File .......................................................................................................................... 106
Printing CHEMCAD Reports ........................................................................................................... 106
Process Flow Diagrams ..................................................................................................................... 106
Flowsheet Databoxes ...................................................................................................................... 106
Stream Boxes ................................................................................................................................................. 107
UnitOp Boxes ................................................................................................................................................ 108
TP Boxes ....................................................................................................................................................... 108
Excel Range Boxes ........................................................................................................................................ 109
Printing a Process Flow Diagram ................................................................................................. 110
Chapter 9 – Customizing CHEMCAD .............................................................................................. 111
Flowsheet Templates ......................................................................................................................... 111
Creating a Template ....................................................................................................................... 112
Viewing a Template’s Properties .................................................................................................. 112
Applying a Template ...................................................................................................................... 112
Renaming or Deleting a Template ................................................................................................ 112
Creating Custom Components ......................................................................................................... 113
Adding a Single Component ......................................................................................................... 113
Creating the Component ................................................................................................................................ 113
Regressing Data into the Component ............................................................................................................ 116
Pseudocomponent Range .............................................................................................................. 117
Importing a Neutral File ................................................................................................................ 118
Customizing Thermodynamics ........................................................................................................ 119
Creating a Custom K‐value or Enthalpy Model ......................................................................... 119
Creating a Custom Mixing Rule ................................................................................................... 120
Visual Basic Applications (VBA) ...................................................................................................... 120
Defining a Reaction, Mixing Rule, or UnitOp ............................................................................ 120
Using a VBA‐defined Reaction ..................................................................................................... 121
Using a VBA‐defined Mixing Rule ............................................................................................... 122
Using a VBA‐defined UnitOp ....................................................................................................... 122
Creating Custom UnitOp Symbols .................................................................................................. 123
Starting the UnitOp Designer ....................................................................................................... 123
Drawing and Sizing the Symbol ................................................................................................... 123
Saving the Symbol Drawing .......................................................................................................... 124
Adding and Locating Ports ........................................................................................................... 125
Specifying Ports .............................................................................................................................. 125
Publishing the UnitOp Symbol ..................................................................................................... 126
CHEMCAD Version 7 User Guide vii
Time‐saving Strategies for Creating Multiple Custom Symbols ............................................. 126
Use an Existing Drawing as a Starting Point for another UnitOp .................................................................. 126
Clone a Custom UnitOp Symbol and Change Port Configuration................................................................. 127
Saving a Published UnitOp for Later Port Reconfiguration .......................................................................... 127
Cloning from the Flowsheet with Publish to Palette...................................................................................... 128
Creating Custom UnitOps ................................................................................................................ 128
Creating a Custom UnitOp Dialog Box ....................................................................................... 129
Customized Costing Calculations .................................................................................................... 130
Chapter 10 – Data Interfaces ............................................................................................................... 131
Excel Data Mapping ........................................................................................................................... 132
Creating an Excel Data Map .......................................................................................................... 132
Data Map Execution Rules ............................................................................................................ 135
Creating Excel UnitOps ..................................................................................................................... 137
Specification Sheets ............................................................................................................................ 137
Using CHEMCAD as an OPC Server .............................................................................................. 138
OPC Applications ........................................................................................................................... 138
OPC Compliance ............................................................................................................................. 139
Enabling CHEMCAD as an OPC Server ..................................................................................... 139
Reading and Writing Values to CHEMCAD Using OPC ......................................................... 139
OPC Server Operations .................................................................................................................. 140
CHEMCAD OPC Namespace ....................................................................................................... 140
COM Interfaces ................................................................................................................................... 141
Connecting Excel and CHEMCAD: A Simple COM Interface ................................................. 141
Using the VBClient Example ........................................................................................................................ 142
A Peek under the Hood .................................................................................................................................. 142
viii CHEMCAD Version 7 User Guide
Chapter 1
Introduction to CHEMCAD
Welcome to CHEMCAD Version 7, a powerful and effective software tool for
chemical process simulation. Whether you’re a new or experienced CHEMCAD user,
you’ll appreciate the program’s user‐friendly, feature‐rich interface. Creating
flowsheets and running simulations is fast and easy with CHEMCAD, and the
program is highly customizable to fit your needs and the way you work.
This User Guide will help you get up and running with CHEMCAD, from
installation and licensing to details on using dynamics and data interfaces.
CHEMCAD Version 7 User Guide 1
Introduction to CHEMCAD
CHEMCAD combines a state‐of‐the‐art graphical user interface (GUI), an
extensive chemical component database, a large library of thermodynamic data, and
a library of the most common unit operations to give users the ability to provide
significant and measurable returns on their investment. In addition, the program is
customizable to allow custom chemicals, thermodynamics, unit operations,
calculations, and reporting—all ingredients for a powerful user experience.
CHEMCAD is capable of modeling continuous, batch, and semi‐batch processes,
and it can simulate both steady‐state and dynamic systems. This program is used
extensively around the world for the design, operation, and maintenance of chemical
processes in a wide variety of industries, including oil and gas exploration,
production, and refining; gas processing; commodity and specialty chemicals;
pharmaceuticals; biofuels; and process equipment manufacturing.
Within all of these industries, chemical engineers work every day with
CHEMCAD to address a variety of challenges:
• Initial design of new processes
• Optimization or de‐bottlenecking of existing processes
• Performance monitoring of processes
• Design and rating of process equipment such as vessels, columns, heat
exchangers, piping, valves, and instrumentation
• Evaluation of safety relief devices
• Heat exchanger sizing
• Pressure and flow balancing of complex piping networks
• Reconciliation of plant data
• Economic comparisons of process alternatives
• Advanced process control (APC), including model predictive control (MPC),
real‐time optimization (RTO), and operator training systems (OTS)
• Scale‐up of processes from lab‐scale to pilot‐scale, and from pilot‐scale to full‐
scale
• Binary interaction parameter (BIP) regression from process or lab data
• Batch reaction rate regression from process or lab data
No matter how complex your process, CHEMCAD is capable of delivering the
results you need to stay competitive in an increasingly fast and fluid global market.
Easy to learn and highly customizable, CHEMCAD can put future‐proof solutions
within easy reach of your engineering staff.
2 CHEMCAD Version 7 User Guide
Introduction to CHEMCAD
CC-STEADY STATE
The main CHEMCAD product, known as CC‐STEADY STATE, enables you to
design new processes, rate existing processes, and optimize processes in steady state.
CC-DYNAMICS
The module known as CC‐DYNAMICS makes it possible to design new and rate
existing processes using a dynamic simulation. This module is fully integrated with
CHEMCAD to make switching between steady state and dynamics easy and
intuitive. Using CC‐DYNAMICS, you can easily simulate everything from simple
vessel accumulation to complex control systems on columns. This module also
provides tools for simulation of continuous stirred‐tank reactors (CSTRs), including
complex reaction rate and pressure calculation.
CC-BATCH
The CC‐BATCH product enables you to design, rate, or optimize a batch distillation
column. CC‐BATCH includes a scheduling interface to allow an “operation step”
approach to simulation of batch columns.
CC-THERM
The CC‐THERM product lets you design a single heat exchanger, or vet a vendor’s
heat exchanger design. It is also ideal for customers who want to rate existing
exchangers in new service, or to perform calculations on hypothetical situations. CC‐
THERM can simulate shell‐and‐tube, air‐cooled, plate‐and‐frame, and double‐pipe
exchangers. Full integration with CHEMCAD makes it possible to calculate exit
conditions from exchanger geometry for high‐fidelity simulations.
CC-SAFETY NET
The CC‐SAFETY NET product provides the capability to design or rate piping
networks and safety relief devices and systems, in both steady‐state and dynamic
systems. The steady‐state features of CC‐SAFETY NET are included with CC‐
STEADY STATE. This product enables users to make simultaneous flow‐ and
pressure‐balanced simulations—even in reverse‐flow situations—for single‐ or
multi‐phase flow.
CC-FLASH
The CC‐FLASH module provides physical property and phase equilibrium data, as
well as property prediction and regression. CC‐FLASH is a subset of CC‐STEADY
STATE, and is meant for customers who do not need full flowsheet simulation tools.
CHEMCAD Version 7 User Guide 3
Introduction to CHEMCAD
CC-STEADY STATE
CC-SAFETY NET
CC-DYNAMICS
CC-THERM
CC-BATCH
CC-FLASH
VB/COM/OPC/Data Map 9 9
Sensitivity/optimization 9 9 9
Sizing (line/valve/orifice/vessel) 9 9 9
Run steady state 9 9 9 9 9
Run dynamics 9 9
Run recycles 9 9 9
Costing 9 9 9
Reconciliation 9 9
Sizing columns 9 9 9
Sizing heat exchangers 9
Economics 9 9
Reports (incl. Excel) 9 9 9 9 9 9
DIERS 9 9 9
CO2 solid 9 9 9 9
Hydrates 9 9 9 9
Depress 9 9 9 9
TOC/COD 9 9 9 9
Pure regression 9 9 9 9 9 9
BIP regression 9 9 9 9 9 9
Electrolyte regression 9 9 9 9 9 9
Rate regression 9 9
Units calculator 9 9 9 9 9 9
Execute parser 9 9
Environmental report 9 9 9 9 9 9
Simple calculator 9 9 9 9 9 9
Spec sheet 9 9 9 9 9
4 CHEMCAD Version 7 User Guide
Introduction to CHEMCAD
UnitOps by Module
The availability of certain unit operations, or UnitOps, in CHEMCAD simulations is
a function of which modules you have licensed. The following matrix lists all
available UnitOps and the CHEMCAD modules associated with them.
CC-STEADY STATE
CC-SAFETY NET
CC-DYNAMICS
CC-THERM
CC-BATCH
CC-FLASH
Baghouse filter 9 9
Batch column 9
Batch reactor 9
Calculator 9 9
Centrifuge 9 9
Component separator 9 9
Compressor 9 9 9
Control valve 9 9 9
Controller 9 9 9
Crusher/grinder 9 9
Crystallizer 9 9
Cyclone 9 9
Divider 9 9 9 9
Electrostatic precipitator 9 9
Equilibrium reactor 9 9
Excel unit 9 9
Expander 9 9 9
Fired heater 9 9
Flash 9 9 9 9
Gibbs reactor 9 9
Heat exchanger 9 9 9 9
Hydrocyclone 9 9
Kinetic reactor 9 9
Liquid/liquid extractor 9 9
LNGH exchanger 9 9
Loop 9 9
Membrane 9 9
CHEMCAD Version 7 User Guide 5
Introduction to CHEMCAD
CC-STEADY STATE
CC-SAFETY NET
CC-DYNAMICS
CC-THERM
CC-BATCH
CC-FLASH
Mixer 9 9 9 9
Node 9 9 9
PID controller 9 9 9
Pipe simulator 9 9 9
Polymer reactor
Pump 9 9 9
Ramp controller 9 9 9
Relief device 9 9
Run subflowsheet META unit 9 9
SCDS distillation column 9 9
Screen 9 9
Sedimentator 9 9
Shortcut column 9 9
Solids dryer 9 9
Solids washer 9 9
Stoichiometric reactor 9 9
Stream reference 9 9
Tank 9
Time delay 9 9
Time switch 9 9
Tower distillation column 9 9
Tower plus distillation column 9 9
User-added module 9 9
Vacuum filter 9 9
Valve 9 9 9
Venturi scrubber 9 9
Vessel 9 9
Vessel reactor 9 9
6 CHEMCAD Version 7 User Guide
Chapter 2
Getting Started with CHEMCAD
To start using CHEMCAD, you’ll need to obtain the software, install it on your
computer, and set up a valid software license. This chapter provides step‐by‐step
instructions for these tasks.
Before you begin, please ensure that your PC meets the minimum system
requirements, as listed below. It’s also a good idea to find out whether your copy of
CHEMCAD will rely on a network license; if it will, make sure to ask your network
administrator for all the
information that you’ll need
CHEMCAD System Requirements when installation is complete
Processor speed: 500 MHz or higher and it’s time to set up
Operating system: Windows Vista, 7, 8, or 10 licensing.
(all 32- and 64-bit versions)
If you’ll be using a
RAM: 256 MB
hardware dongle to license
Video card: 128 MB or higher video memory
CHEMCAD, make sure the
Display resolution: 1024 x 768 or higher
dongle is inserted into a USB
Hard disk space: 750 MB
port before you attempt to run
Productivity software: Some features require
the program.
Microsoft Office®
To obtain the CHEMCAD
installation file, you’ll need a
live Internet connection and a web browser. You can either download the file
directly onto the system where you plan to install CHEMCAD, or download the file
and place it onto a portable drive for installation on a different computer. In either
case, the download process requires that you log into Chemstations’ User Support
Center.
CHEMCAD Version 7 User Guide 7
Getting Started with CHEMCAD
Figure 2-01: Clicking the Sign in link on the Support Center screen
3. On the My Support page, click the Forgot your password? link, located below
the Sign in button.
Figure 2-02: Clicking the Forgot your password? link on the My Support page
4. On the next screen, enter a valid e‐mail address, and click the Reset my
password button. Be sure to use your company address, as the login system will
match your address against our customer database.
5. If your address is found, you will receive an e‐mail from CHEMCAD Technical
Support, offering a link to reset your password. Follow the instructions in the e‐
mail and at the password reset screen to complete your registration.
Note: In the event you do not receive a password reset e‐mail within 24 hours, your
address may not have been found in our database. Please contact Chemstations
Technical Support (support@chemstations.com) for assistance.
8 CHEMCAD Version 7 User Guide
Getting Started with CHEMCAD
Figure 2-03: The CHEMCAD Suite 7 – InstallShield Wizard screen
Click Next to begin the installation process. The License Agreement screen
appears, listing the terms of the CHEMCAD standard license. Once you’ve read and
understood the license terms, you’ll need to click the I accept the terms in the license
agreement button before you can click Next to proceed. Note that you have the option
to print a copy of the license agreement from this screen.
Figure 2-04: The License Agreement screen
CHEMCAD Version 7 User Guide 9
Getting Started with CHEMCAD
The Destination Folder screen appears next, displaying the name of the folder
into which the CHEMCAD files will be installed by default. Normally, this
destination is C:\Program Files\Chemstations\CHEMCAD (or some variation, based
on your version of Windows), and it is recommended that you use this location
unless you have a specific need to install the program elsewhere. Click the Change
button if you want to change the file destination, or click Next to accept the
suggested destination and proceed.
Figure 2-05: The Destination Folder screen
The Setup Type screen now appears, offering a choice between complete and
custom installation. Each type of installation is described on the screen. Either accept
the default setting of Complete or click Custom to select specific components to
install, then click Next to proceed.
Figure 2-06: The Setup Type screen
This brings you to the Ready to Install the Program screen. Note that on this
screen, and in fact on any screen in the installation process, you can click Back to
return to a previous screen and verify or change your installation options. If you are
satisfied with your settings as they are, click Install to start the installation.
10 CHEMCAD Version 7 User Guide
Getting Started with CHEMCAD
Figure 2-07: The Ready to Install the Program screen
The Installing CHEMCAD Suite screen appears, showing the progress of your
installation with a green status bar.
Figure 2-08: Status bar showing the progress of CHEMCAD installation
During installation, you may notice a second, smaller installation window that
pops up. This shows the progress of various software components that are being
found and installed so that CHEMCAD installation may proceed. To ensure
successful completion of the install procedure, be sure to leave this window open; it
will close automatically when all components are in place.
Figure 2-09: Software component installation message
When installation is complete, you’ll see one final screen, which states that the
InstallShield Wizard has completed installation of the CHEMCAD Suite. Click
Finish to close the installer window.
CHEMCAD Version 7 User Guide 11
Getting Started with CHEMCAD
Figure 2-10: The InstallShield Wizard Completed screen
Licensing CHEMCAD
Before you can use CHEMCAD, you’ll need to set up a licensing scheme of some
type. Depending on your particular licensing agreement, you will use one of several
types of licenses to run CHEMCAD.
License Settings
To run CHEMCAD for the first time, make sure that your dongle (if applicable) is
plugged in properly, and then start the program. From the Windows Start menu,
select All Programs > Chemstations > CHEMCAD 7.
12 CHEMCAD Version 7 User Guide
Getting Started with CHEMCAD
Note: A Standard License screen appears only the first time that you run
CHEMCAD after installation. After you have reviewed the license agreement, click
Yes to continue.
The program opens, displaying a CHEMCAD splash screen. After a few
moments, this screen is replaced by the CHEMCAD License Monitor dialog box,
which displays information about the license(s) that your computer is using to run
CHEMCAD.
Figure 2-11: The CHEMCAD License Monitor, displaying licenses from a local hardware dongle
Note: In some cases, the CHEMCAD screen that appears may display a No License
Found message, which indicates that CHEMCAD has not yet detected a valid license.
If your computer is experiencing slow communication with the license server
system, CHEMCAD may simply need more time to detect the license(s). As soon as
any valid license is found, CHEMCAD will display the CHEMCAD License Monitor
screen.
Normally, this dialog box remains in view for only a few seconds, listing all
product licenses that CHEMCAD has obtained. During that time, you can click
anywhere in the dialog box to keep it open. If you do not click in the dialog box, it
disappears from view, but you can bring it back up at any time by selecting Tools >
Options > Licensing.
While the CHEMCAD License Monitor dialog box is open, you can view the
various CHEMCAD licenses detected for your system and see what method (and
where applicable, which server) is being used to obtain those licenses. If your
organization uses RMS License Manager or a SuperProNet hardware key, you can
also see which other users currently hold various product licenses.
For network licenses, you can right‐click a server name under a particular
product and select a licensing preference (on demand, always, or never) as shown
below.
CHEMCAD Version 7 User Guide 13
Getting Started with CHEMCAD
Figure 2-12: Selecting a network licensing preference
You can use the always or never setting to turn licensing for a product absolutely
on or off, respectively. The on demand setting secures a license only when you begin
to use a specific CHEMCAD feature controlled by a certain product. This setting is
ideal in most situations, as it leaves unused licenses available for other users.
To close the CHEMCAD License Monitor screen, click the Continue button, or
click the X in the top right corner of the screen.
Updating a License
CHEMCAD dongles require re‐programming on a regular basis—either once a year
or more often, depending on your licensing agreement. This is a security measure to
reduce the likelihood that your dongle will be stolen and misused.
The dongle that you use is programmed to work only through the licensed time
period, and when that time has elapsed, the dongle must be updated before you can
continue using CHEMCAD.
Updating a dongle is a relatively simple procedure. Before your license
expiration, you or your software administrator should receive an e‐mail from
Chemstations, with what’s known as a configuration file included as an attachment.
You should save this file to your Windows desktop as soon as you receive it.
Note: If you’ve updated the same dongle in the past, the new configuration file
should have the exact same file name as the previous one. If, while saving the file to
your desktop, you see a Windows message about an existing file with the same
name, you should overwrite the old file (which in any case cannot be used again),
replacing it with the new one.
It’s important to ensure that your configuration file matches your dongle. The
configuration file should be a .DNG file whose name includes a four‐ or five‐digit
code; this code must match the number stamped onto your dongle. If the numbers
14 CHEMCAD Version 7 User Guide
Getting Started with CHEMCAD
don’t match, contact your software administrator or Chemstations support to resolve
the issue.
The update e‐mail also specifies the date on which you’ll need to update your
dongle. Before that date arrives, follow this procedure to perform the update:
1. Start the CHEMCAD program and select Tools > Options > Licensing. This
brings up the CHEMCAD License Monitor dialog box, which displays the
status of all applicable CHEMCAD product licenses, along with your dongle
type and number.
Figure 2-13: The CHEMCAD License Monitor dialog box
2. Click the Setup button to bring up the License Setup dialog box, then click
Update dongle as shown below.
Figure 2-14: Clicking Update dongle within the License Setup dialog box
3. The dialog box now lists all licensing dongles and displays a field for
entering the full path and file name for the dongle update file. Click the
Browse button to navigate to the update file.
CHEMCAD Version 7 User Guide 15
Getting Started with CHEMCAD
Figure 2-15: Browsing for the dongle update file
4. In the Open dialog box, navigate to the location where you saved the .DNG
configuration file. Normally, this is the Windows desktop; if you saved your
configuration file there, click Desktop to tell CHEMCAD where to look for
the file, then click Open.
5. The License Setup dialog box now displays the directory path and file name
for the selected .DNG file. Click OK to update the dongle.
Figure 2-16: Updating the dongle with the selected update file
6. CHEMCAD re‐programs the dongle, and then displays a pop‐up window
stating that the update is complete.
Figure 2-17: Successful re-programming of a CHEMCAD dongle
7. Click OK to close the pop‐up window. If the CHEMCAD License Monitor
screen appears, click Continue to close it.
You should now be able to proceed normally in CHEMCAD.
16 CHEMCAD Version 7 User Guide
Getting Started with CHEMCAD
Online Help
At any time while running CHEMCAD in an active window, you can press the [F1]
key to bring up the CHEMCAD Help screen that’s most appropriate to the task you
are currently performing or the dialog box currently displayed.
In some situations, pressing [F1] will bring up the main CHEMCAD Help
window instead of a particular help screen. From there, you can click the Contents,
Index, or Search tab in the upper left corner of the CHEMCAD Help window, and
use these tools to find the information you need.
You can also go directly to the main CHEMCAD Help window by selecting Help
> Help Topics from the CHEMCAD main menu. Regardless of how you open
CHEMCAD Help, it always opens in a separate window that does not interfere with
the operation of the CHEMCAD program.
CHEMCAD Version 7 User Guide 17
Getting Started with CHEMCAD
18 CHEMCAD Version 7 User Guide
Chapter 3
The CHEMCAD Interface
This chapter takes you on a tour of the CHEMCAD screen, including the menus and
toolbars, the main areas of the screen, and the flowsheet drawing tools. It also shows
you some ways that you can customize the screen and various features so that they
best suit your own way of working.
Workspace
CHEMCAD
Explorer pane
Palette pane
Messages pane
Figure 3-01: The full CHEMCAD program window
CHEMCAD Version 7 User Guide 19
The CHEMCAD Interface
The Workspace
The area in the middle of the screen is known as the workspace. This is the main focus
of the CHEMCAD window, the place where you’ll build and edit flowsheets, view
graphs, and run and tweak process simulations.
When you first launch CHEMCAD, the workspace is solid white. When you start
to build a flowsheet or open an existing simulation, the flowsheet displays in the
workspace.
The workspace uses tabs to enable you to switch between an open simulation and
any related features, such as Excel Data Maps, reports, and plots. At the bottom of
the workspace area, you’ll see one or more tabs whenever a simulation is open.
Each tab includes a button marked with an X; to close any tab, simply click that
tab’s X button.
Figure 3-02: The bottom of the workspace area, showing several tabs and their X buttons
Note that any time you’ve closed a simulation and haven’t yet opened another
file, the workspace displays as a blank gray space.
Figure 3-03: CHEMCAD Explorer tabs
The CHEMCAD Explorer tabs are presented in a tree format, with items
organized into a multi‐level hierarchy. The default view shows only top‐level items,
but you can expand each item to view second‐level items, third‐level items, and so
forth.
At the left of each top‐level item is a small box with a plus sign. To expand an
item, click the plus sign. Two things happen simultaneously when you click: the tree
expands to show that item’s contents, and the plus sign becomes a minus sign. You
can hide (or collapse) the lower‐level items again by clicking the minus sign, which
then turns back into a plus sign. Figure 3‐04 shows an example of a CHEMCAD
Explorer item in collapsed and expanded view.
20 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
Figure 3-04: Clicking the plus sign to expand an item (left); the resulting view (right)
Expanding and collapsing items in the CHEMCAD Explorer tabs is one way that
you can make the best use of your screen space when working in CHEMCAD.
CHEMCAD Version 7 User Guide 21
The CHEMCAD Interface
• Saved Charts: Provides quick access to previously‐saved charts for this
simulation
• Groups: Provides an easy way to categorize UnitOps, streams, and
components
• Templates: Stores and organizes stream and UnitOp specifications that you
can “clone” for re‐use
Expand any of these items to see and use specific features, which are described in
further detail in the appropriate chapters of this user guide.
22 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
Selecting a Palette
To select a palette, simply click its title bar. The selected palette expands in place, as
shown in Figure 3‐05.
Figure 3-05: The expanded Reactors palette
Figure 3-06: A Tower Plus icon in (left to right) Grayscale, System Color, and Wireframe color
schemes
You can apply a color scheme to any built‐in UnitOp palette, to determine the
appearance of any new UnitOps you add from that palette to a flowsheet.
Before you apply a color scheme to a palette, first ensure that the desired palette
is open. Then click the current color scheme name, which is displayed next to the
palette name; this will cause a selection list to drop down. Simply click a color
scheme name to switch to that scheme.
Once you have applied a color scheme to a palette, the icons you drag from that
palette onto the flowsheet will look just like the examples on the palette. Changing
CHEMCAD Version 7 User Guide 23
The CHEMCAD Interface
the color scheme of a palette does not affect any icons previously dragged onto the
flowsheet from that palette.
Note: Before you attempt to rearrange symbols on a palette, make sure that the Lock
Palette feature is turned off. Normally, this setting protects you from unintentionally
moving symbols around when you are placing items onto a flowsheet.
To turn the feature on or off, right‐click any palette’s title bar and look for the Lock
Palette menu item. A check mark indicates that the feature is turned on; simply click
to clear the check mark and unlock all palettes. It’s a good idea to return palettes to a
locked state when you are not actively editing them.
To move a UnitOp symbol to a new location on the palette, click and drag the
symbol. Release the mouse button when the symbol is situated where you want it.
Other symbols on the palette will shift their positions to make room for the newly
placed item.
24 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
Renaming a Palette
To change the name of any palette, first open the palette in question. Then right‐click
the palette heading and select Rename. In the Rename Palette box, type the name
you want to use for the palette and click OK. The palette will now display the new
name.
Note: The Rename command is very useful when you have just created a new
custom palette, as the initial name for all new palettes is New.
Note: Using two colors gives the symbol a three‐dimensional appearance; to create a
flat look, choose the same color for the primary and secondary options.
Figure 3-07: Default Grayscale colors in the Edit Color Scheme dialog
Choose new colors and then click OK. The symbol appears with the colors you
selected on the current palette.
CHEMCAD Version 7 User Guide 25
The CHEMCAD Interface
Figure 3-08: The standard Equilibrium Reactor symbol with (from left) Grayscale, System Color,
two-tone custom, and single custom coloring
Repeat this process for any other UnitOp symbols for which you want to create
custom colors. The changes you make in a custom color scheme will affect only those
palettes to which you assign the scheme.
You can remove a custom color scheme simply by right‐clicking any palette
heading and selecting Delete Color Scheme > [scheme name]. Before you do this, be
sure the scheme you are deleting is not currently in use by any palettes.
26 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
The Toolbar
The CHEMCAD toolbar provides buttons that are common to most Windows
applications, such as New, Open, Save, and Print, along with buttons that are
specific to chemical process simulation.
To discover the use of a particular button, simply point your mouse cursor at the
button and watch for the tooltip to appear, as shown in Figure 3‐09.
Figure 3-09: Viewing a button’s tooltip
Toolbar buttons provide quick, one‐click access to frequently‐used commands
that are also available via the CHEMCAD menus.
CHEMCAD Version 7 User Guide 27
The CHEMCAD Interface
If having all of these items visible leaves you less workspace than you would
prefer, or if the location of one or more panes is less than optimal for the way that
you work, you can hide or move panes to customize your CHEMCAD screen.
Resizing a Pane
The simplest way to alter the appearance of a pane is to resize it. You can make the
CHEMCAD Explorer and Palette panes wider or narrower, or make the Messages
pane shorter or taller, by moving the inside edge, or wall, of the pane toward or
away from the edge of the main window.
To resize a pane, start by positioning your mouse cursor at the inside wall of the
pane—that is, the right edge of the CHEMCAD Explorer pane, the left edge of the
Palette pane, or the top edge of the Messages pane. When the cursor is in the correct
position for resizing, the normal pointer will be replaced with a two‐headed arrow
as shown in Figure 3‐10.
28 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
Figure 3-10: The two-headed arrow cursor used for resizing panes
When you see the two‐headed arrow, click and drag in the direction you want to
move the pane wall. A thick gray line shows a preview of the new pane size; when
you release the mouse button, the resized pane appears.
Moving a Pane
In addition to resizing, you can also move any of the panes in the CHEMCAD
window, either to a different edge of the screen or to the middle of the screen. You
can also move groups of buttons from their default positions on the toolbar.
Initially, all of the panes and button groups are docked, meaning that they are
“snapped into” an edge of the screen or the toolbar area. When you undock an item,
you can put it in the location of your choosing, away from the screen edge.
To undock a pane, click and drag the pane’s title bar, that is, the blue bar at the
top of the pane that shows the pane name. To undock a button group, you’ll need to
click and drag the row of four dots running along the left edge of the leftmost button
in the group.
Note: In the case of the Messages pane, the title bar runs along the left edge of the
pane in its default docking position.
If you drag the pane or button group into the workspace area, you’ll see a gray
box representing the position the item will occupy when you release the mouse
button. If you don’t like the new position, you can click the item’s title bar and drag
it elsewhere, including its original position.
You can also dock a pane to a different edge of the screen, or move button
groups around within the toolbar area, instead of undocking these items.
CHEMCAD Version 7 User Guide 29
The CHEMCAD Interface
These two panes can take up a fair amount of horizontal screen space, and
making them very narrow isn’t an ideal way to work. Pinning and unpinning
provide a way to view full‐width CHEMCAD Explorer and Palette panes when you
need these tools, while also freeing up space when you aren’t using them.
Whenever either of these panes is docked at an edge of the screen, it is in one of
two states:
• Pinned, meaning that the pane is always visible
• Unpinned, meaning that the pane is mostly hidden from view, and appears only
on demand
By default, all CHEMCAD panes are initially pinned in place. You can choose to
unpin a pane if you prefer to have some extra space on the screen. To unpin a pane,
find the tiny pushpin icon in the pane’s title bar, next to the X icon that enables you
to close the pane. If the pane is stationary, you’ll see that the pin is upright with its
point down.
Figure 3-11: The icon indicating a pinned, or stationary, pane
If you click the pin icon, the pane suddenly disappears from view—but it isn’t
gone. Instead, a small gray tab bearing the name of the palette appears at the edge of
the screen where the pane is docked. To see the pane reappear, you only have to roll
your mouse over that tab. When the pane appears, you’ll notice that the pushpin
icon is now pointed to the side. Use the tools on the CHEMCAD Explorer or Palette
normally; then, when you no longer need the pane, just move the mouse pointer
elsewhere. The pane will automatically hide itself until the next time you roll the
mouse over the tab.
Figure 3-12: An unpinned pane in use; note the sideways pin icon
To re‐pin an unpinned pane, point to the tab to make the pane appear and then
click the pin icon. The pin turns so that it is once again upright, and the pane is once
again a permanent fixture on the CHEMCAD screen.
30 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
Figure 3-13: The Flowsheet toolbar (Grid, Snap to Grid, Snap to Center)
You can turn on a workspace grid to use as a guide while creating your
flowsheet. Select View > Grid Visible to toggle this feature on or off, or use the Grid
toolbar button.
The option called Snap to Grid can help with alignment of objects on the
flowsheet. When this option is turned on, items that you move on the workspace will
align themselves with the nearest vertical and horizontal grid lines. Again, use the
View menu to access this option, or click the Snap to Grid button on the toolbar to
toggle the option on or off.
Selecting View > Change Grid Size brings up the Grid dialog box, which enables
you to customize the look and spacing of the grid lines when the grid is turned on.
Finally, the Snap to Center feature helps you to neatly line up flowsheet
elements relative to one another. When this option is turned on, items that you move
around on the workspace will show when they are centrally aligned with nearby
objects, as indicated by a blue dotted line.
Figure 3-14: The Snap to Center feature in action, showing when objects are centrally aligned
CHEMCAD Version 7 User Guide 31
The CHEMCAD Interface
Figure 3-15: The Arrange toolbar: (Rotate left, Rotate right, Flip horizontal, Flip vertical, Bring
to front, Send to back)
Figure 3-16: The Lock toolbar (Lock Flowsheet Elements, Unlock Flowsheet Elements)
To lock a specific object in place, select that object (stream, UnitOp, text box,
drawn object) and then click the Lock Flowsheet Elements button. Now, when you
click the locked object, you’ll see small yellow lock icons instead of the usual green
sizing handles. To unlock the object, simply select it and click Unlock Flowsheet
Elements.
Figure 3-17: A heat exchanger as it appears when locked (left), and when unlocked (right)
You can change the lock status of objects individually, or select a block of items
on a flowsheet and change the all with one click of the lock or unlock button.
To lock or unlock the entire flowsheet, simply click into a blank area of the
workspace to ensure that nothing is currently selected, then click the desired locking
button. This approach affects all items currently on the flowsheet; if you add more
items, they will be unlocked at first by default.
32 CHEMCAD Version 7 User Guide
The CHEMCAD Interface
Figure 3-18: The Draw toolbar (Line, Arrow line, Polygon, Ellipse, Rectangle, RoundRect,
TextBox)
a second time to create the first side of your polygon. After the second click, you’ll
begin to see the open area being created. Continue moving the cursor and clicking
until you are ready to place your last point, and then double‐click to complete the
shape and turn off the Polygon tool.
Note that you can hold down the [SHIFT] key while using the Polygon tool to
create a right triangle.
Figure 3-19: The Align toolbar (Group, Ungroup, Align Left, Align Top, Align Bottom, Align
Right, Align Middle, Align Center, Space Across, Space Down)
To see these tools in action, imagine that you’ve started a flowsheet by placing
three Feed arrows on the workspace, somewhat randomly. You can select them all
and click Align Left to line them up precisely. Then select them again and click
Space Down to distribute them evenly within the vertical space.
Figure 3-20: Feed arrows (left to right) randomly placed, left-aligned, and evenly distributed
Now that the arrows are arranged the way you want, you can select them one
more time and click Group; this will ensure that they remain in the same position
relative to one another if they are ever moved.
Grouped objects will appear highlighted all together if you click on any object in
the group. To separate grouped objects, simply click anywhere on the group to
highlight it and then click Ungroup.
command to reverse the last change you made; simply select Edit > Undo, or use the
key combination [CTRL‐Z].
You can use the Undo command to retract up to the last 99 actions that you
performed since the last time you opened the current simulation file.
Flowsheet Quickview
The Flowsheet Quickview feature is turned on by default when you install
CHEMCAD. This handy tool enables you to see a quick data ‘snapshot’ for any
stream or UnitOp on a flowsheet, without even clicking the mouse.
To use this feature, simply hover the mouse over any part of a stream line or
UnitOp symbol. This brings up a pop‐up window with relevant data for that
particular stream or UnitOp.
Figure 3-21: Quickview pop-up windows for a distillation column (left) and a product stream
By default, the Quickview window for streams includes temperature and
pressure, stream enthalpy, mole vapor fraction, and overall flow rate, plus
composition flow rates. You can customize the stream information displayed in the
Quickview window using property sets, which are discussed in detail in Chapter 8,
Output and Reports.
For UnitOps, Quickview displays key parameters about the equipment, and in
some cases about the streams entering and exiting the equipment, depending on the
UnitOp type.
To turn off the Quickview feature, select View > Flowsheet Settings > Flowsheet
Quickview, or simply click the Flowsheet Quickview button on the toolbar.
Figure 3-22: The Flowsheet Quickview button
CHEMCAD Version 7 User Guide 35
The CHEMCAD Interface
36 CHEMCAD Version 7 User Guide
Chapter 4
Working with Simulation Files
All of the work that you do with CHEMCAD is stored in simulation files. Each
discrete simulation is packaged into a single file that is portable and easy to handle.
All the details of the simulation—from UnitOp specifications to stream composition
to thermodynamics—are included in this file. This chapter describes the various
ways that you can access and manage CHEMCAD simulation files.
Figure 4-01: CHEMCAD 7 files in the My Simulations directory
CHEMCAD Version 7 User Guide 37
Working with Simulation Files
Example Files
Especially if you’re new to CHEMCAD, it’s a good idea to open and practice
working with some example files before creating your own simulations. For this
purpose, we’ve created numerous examples of simulations for typical chemical
processes. You can open, view, and edit any example file, and even save a copy in
another location to jump‐start a simulation of your own.
The CHEMCAD example files are automatically copied to your computer with a
complete CHEMCAD installation. The examples are organized by process type and
located in the \My Documents\My Simulations\Examples directory.
Note: An alternative method for opening a simulation file is simply to drag and drop
the simulation’s filename from a Windows Explorer window onto the CHEMCAD
workspace.
If you use CHEMCAD on a network and share files with other users, it’s possible
that you could try to open a simulation that is already open for editing by another
user. If you should attempt to open a simulation that is unavailable for editing, a
message box will appear. You can choose to save the simulation with a new name
and/or location, open a read‐only copy of the simulation, or cancel the open
operation.
38 CHEMCAD Version 7 User Guide
Working with Simulation Files
Figure 4-02: Notification that a simulation is already in use
If you should have trouble locating a particular simulation, you can search your
hard drive or network for all files with a .CC7 file extension.
Saving a Simulation
To save all changes in a simulation that you have already named, select File > Save
or click the Save button on the toolbar. You can also press [CTRL + S] on the
keyboard to save the file.
Note: In some cases, such as the built‐in CHEMCAD example files, existing files may
be set as read‐only to prevent accidental overwriting. You can save a copy of a read‐
only file using a different file name and/or file location.
To save a new simulation that you haven’t yet named, select File > Save As. The
Save As dialog box appears, with CHEMCAD 7 (*.cc7) as the default file type. Leave
the file type as it is, give the file a unique name, and if necessary navigate to a new
file location. Click Save to close the dialog box and return to the saved simulation.
CHEMCAD Version 7 User Guide 39
Working with Simulation Files
Figure 4-03: Giving a new simulation a unique name
Note: Any changes you make to a simulation are not saved until you use the Save or
Save As command. This enables you to choose which changes to save or discard.
Saving and storing all of your simulations in the same main directory helps
prevent the lost time and frustration that can result when files are scattered in
different locations. It is recommended that you store your simulations in the My
Simulations directory, which is created automatically within My Documents when
you install CHEMCAD.
40 CHEMCAD Version 7 User Guide
Working with Simulation Files
E-mailing a Simulation
Sending a simulation file via e‐mail is quick and easy. You can either send a
simulation from within the CHEMCAD screen or attach the simulation file from
within an e‐mail program.
Figure 4-04: E-mailing directly from the CHEMCAD window
You can now enter your recipient information and add any message text, then
send the message. It’s a good idea to check the attachment information to see the size
of the simulation file, as these files can in some cases be quite large.
Attaching to an E-mail
You can also e‐mail any simulation that is stored on a local hard drive or network
without opening CHEMCAD. This comes in handy if you are working on a
computer or other device where you do not have access to a local e‐mail program, or
one where CHEMCAD is not currently installed.
To do this, simply create a new message, using your web mail or other e‐mail
account. Then use the e‐mail program’s command for attaching a file. Navigate to
the directory where the simulation is located, select the appropriate .CC7 file, and
add the file as an attachment before sending.
CHEMCAD Version 7 User Guide 41
Working with Simulation Files
Figure 4-05: Adding a .CC7 file as an attachment in MS Outlook
Figure 4-06: Converting a CHEMCAD 6 file to the .CC7 format
42 CHEMCAD Version 7 User Guide
Working with Simulation Files
Note: By default, an imported simulation will use the standard CHEMCAD 7 UnitOp
symbols in place of those used in CHEMCAD 6. If you leave this setting as it is, all
standard CHEMCAD 6 UnitOp symbols will be mapped to the corresponding
CHEMCAD 7 symbols, in the default Grayscale color scheme. Any custom symbols
will be recreated on the new file’s flowsheet. If you prefer to see CHEMAD 6‐style
UnitOp symbols, change the selection to Do not use CHEMCAD 7 UnitOp symbols
before proceeding.
Click Save to bring up the Save As dialog box, where you can either keep or
change the file’s name and select a location for the new CHEMCAD 7 copy. Click
Save to create and open the new file.
To import a simulation file that was created with CHEMCAD 5, you must first
open and save that file using CHEMCAD 6, and then bring the file into CHEMCAD
7 using the method described here.
CHEMCAD Version 7 User Guide 43
Working with Simulation Files
44 CHEMCAD Version 7 User Guide
Chapter 5
Building and Using a Basic Simulation
The types of simulations you can create using CHEMCAD are many and varied, but
the basic procedure for creating a simulation can be broken down into the following
common steps:
1. Start a new simulation.
2. Specify engineering units for the simulation.
3. Select chemical components for the process.
4. Select K‐value and enthalpy options for the process.
5. Draw the flowsheet with appropriate streams and unit operations.
6. Define the feed streams used in the process.
7. Enter specifications for the unit operations.
8. Run the simulation.
9. Review the results of the simulation.
CHEMCAD Version 7 User Guide 45
Building and Using a Basic Simulation
Figure 5-01: The Select components button
46 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
Figure 5-02: The Select Components dialog box
The Available Components column lists the contents of the CHEMCAD
component database, while the Selected Components column lists the components
currently included in this simulation. For a new simulation, the Selected
Components list is empty at first.
Every chemical that will be part of the process, whether it’s a feed stream,
product, or utility, must be listed on this simulation’s component list.
Finding a Component
Because of the large number of components in the CHEMCAD component database,
scrolling up and down the list of available components can be time‐consuming. To
find a specific component quickly, use the Search field at the bottom of the Select
Components dialog box.
Type the name of the chemical you want to find in the Search field. With each
letter that you type, CHEMCAD suggests possible matches in the Available
Components list. In the following example, typing the letters wa in the Search field
has highlighted the Water component.
CHEMCAD Version 7 User Guide 47
Building and Using a Basic Simulation
Figure 5-03: Using the Search field to locate the Water component
Note that in some situations, the first result may not be the one you want. For
example, typing ethane in the Search field brings up the Methane component at
first. To see the next match for your text, click Next; continue clicking this button as
needed until you find the desired component.
The Search field accepts both text and numeric entries. By default, CHEMCAD
will search for your entry among all chemical names, chemical formulas, and
CHEMCAD database IDs; if you like, you can also search by CAS number. To turn
any of these search options on or off, click the Options button below the Search field.
This brings up the Search Options dialog box, where you can specify which data to
include in your component searches.
Figure 5-04: Selecting which data to include in component searches
Note: You can add your own custom components to the CHEMCAD component
database. For more details about this feature, see Chapter 10, Data Interfaces.
48 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
Adding a Component
Once you’ve located the component you want in the Available Components list,
simply double‐click the component to add it to the Selected Components list for your
simulation.
You can also select multiple components in the Available Components list and
then click the right arrow button, located between the two columns, to add all of the
selected components to your simulation. To select multiple components, use
Windows’ standard selection methods of holding down [SHIFT] to select contiguous
items or holding down [CTRL] to select non‐contiguous items.
Figure 5-05: Adding multiple components using the right arrow button
If you would like to duplicate the component list from an existing simulation,
click Copy From Another Simulation. In the resulting Open dialog box, navigate to
the desired simulation, select that simulation, and click Open. The Selected
Components list is now populated with the components used in the simulation you
selected; you can add or delete items to customize the list.
CHEMCAD Version 7 User Guide 49
Building and Using a Basic Simulation
50 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
Figure 5-06: The Thermodynamic Settings button on the toolbar
2. This opens the Thermodynamic Settings dialog box. Start by determining,
based on your process knowledge, whether your system has two liquid
phases or a single liquid phase. In the Global K‐value Model field, select a
method that can calculate the phase behavior relevant to your system.
CHEMCAD Version 7 User Guide 51
Building and Using a Basic Simulation
3. Based on the specific circumstances of your process, make any needed
alterations to the options displayed on the K‐value Models tab. Note that the
options appropriate to your selected K‐value method are displayed in black,
while irrelevant options are displayed in gray.
Note: When you change the Global K‐value Model selection, CHEMCAD
may automatically update the Global Enthalpy Model setting as
appropriate. If this happens, you will see a message on the K‐value Models
tab. You can change the selected enthalpy model by making a new selection
in the Enthalpy Models tab.
4. Click the Enthalpy Models tab, select the most appropriate model in the
Global Enthalpy Model field, and make any other changes to the options on
this tab as needed for your process.
5. Click the Transport Properties tab and verify that the settings there are
appropriate for this simulation. Change any settings as needed and then click
OK to close the Thermodynamic Settings dialog box.
6. If you’ve made any changes, a message box appears: All streams should be
reinitialized. Proceed with reinitialization? Click Yes to reinitialize all streams
now, or No if you’d prefer to wait and reinitialize the streams later.
Adding UnitOps
Start by adding UnitOp symbols for the equipment that will be part of your
simulation. The tools for adding UnitOps to a flowsheet are located in the Palette
pane, which by default displays on the right margin of the CHEMCAD window.
This pane offers specialized palettes for UnitOp categories such as Heat
Exchangers and Reactors, but the default palette view is All UnitOps, which displays
all of the available UnitOp icons at once.
Note: If you do not at first see the Palette pane, it may have been turned off. To
restore this pane, select View > Palette from the main menu. If the pane is turned
on but you only see the word Palette sideways in the upper right corner of the
screen, the pane is unpinned; see Chapter 3, The CHEMCAD Interface, for
information about pinning and unpinning panes.
To place a UnitOp icon on your flowsheet, follow these steps:
52 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
1. On the All UnitOps palette, find the appropriate UnitOp symbol for the
equipment you want to represent. If you are unsure about which UnitOp best
fits your purposes, you can see a brief pop‐up description of any palette item
by hovering your mouse pointer over its symbol.
2. Click the symbol and drag it onto the workspace where you want to place the
UnitOp. When you release the mouse button, the UnitOp symbol appears
where you clicked.
Note: Items that are already in place on the flowsheet will not be affected when
you select a new default symbol for a UnitOp.
To view the symbols available for a given UnitOp, right‐click the current symbol
on the palette. A subpalette will pop up, displaying all available symbols.
Figure 5-07: Viewing the subpalette for the Divider UnitOp
From a subpalette, you can drag any symbol onto the flowsheet, just like the
symbols on the main palette. When you do this, the selected symbol appears on the
flowsheet and the subpalette automatically closes.
To change the default symbol for a UnitOp, first right‐click to open the
subpalette, then hold down the [CTRL] key and click the symbol you want to use.
After you do this, the symbol you selected appears on the main palette. You can
change the default icon for a UnitOp as often as you like.
CHEMCAD Version 7 User Guide 53
Building and Using a Basic Simulation
UnitOp IDs
When you place UnitOps on a flowsheet, CHEMCAD assigns each one an ID
number that is unique within the simulation. The UnitOp number is a vital identifier
for the unit, and is used in various reports and charts as you work with the
simulation.
The UnitOp ID is displayed in an oval, easily distinguishable from the
rectangular boxes used to display Stream IDs.
Figure 5-08: A UnitOp symbol with its ID oval
The default position of a UnitOp ID is just above and to the left of the unit’s
flowsheet symbol. If you subsequently move the UnitOp symbol, its ID remains in
the same relative position.
54 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
In some situations, you may want to move a UnitOp ID from its default location.
To do this, click the UnitOp to highlight it, then move your mouse cursor over the
UnitOp ID oval. When you see the cursor change to a curved hand shape, click and
drag the ID oval to the desired location.
Figure 5-09: The hand cursor for moving a UnitOp ID (left), an ID being moved to the opposite
side of the UnitOp symbol, and the ID oval in its new location
UnitOp ID Ranges
When you place UnitOps on a flowsheet, CHEMCAD assigns each one a UnitOp ID
number that is unique within the simulation. The UnitOp ID number is an important
identifier for the unit, and is used in various reports and charts as you work with the
simulation. By default, your UnitOps will be numbered, starting at 1, in the order in
which you create them; all types of equipment share the same pool of ID numbers.
If you want to group your UnitOps numerically by equipment type, you can use
the Starting IDs feature to accomplish this.
Select Format > Starting IDs, which brings up the Stream and UnitOp Starting
IDs dialog box. Here you’ll see each type of UnitOp available in CHEMCAD, each
with a default setting of 1. This means that any new UnitOp will be assigned an ID
from the same number pool—the next number (1 or greater) that has not been used
yet in this simulation.
To set up separate ranges of numbers for different equipment types, you can edit
the values in the Stream and UnitOp Starting IDs screen. For example, you could set
the Heat Exchanger value to 200, the Pump value to 300, the Pipe value to 400, and
so on, using any starting values that are meaningful to you. Any UnitOp type you
don’t assign a starting value will pull ID numbers from the pool starting with 1,
skipping any numbers that are already assigned.
UnitOp Names
In addition to the assigned ID, you can give a UnitOp a name, using up to 11
alphanumeric characters. This name appears in the UnitOps area of the CHEMCAD
Explorer pane, on certain reports, and optionally on the flowsheet with the UnitOp
ID.
To add a UnitOp name, right‐click the UnitOp on the flowsheet and select Edit
Name; type the name in the resulting dialog box and click OK.
CHEMCAD Version 7 User Guide 55
Building and Using a Basic Simulation
By default, a newly added UnitOp name will appear beneath the number in the
in the UnitOp ID box. To hide a single UnitOp’s name, right‐click the UnitOp and
clear the check mark next to Show Name; simply check this menu item again to
make the UnitOp name visible again.
To view or hide all UnitOp names on the flowsheet with a single command,
select View > Flowsheet Settings and choose either Show All UnitOp Names or
Hide All UnitOp Names.
3. Click and drag toward the desired inlet on the downstream UnitOp. When
you see the cursor change to an anchor shape, and the inlet port outlined in
red, release the mouse button.
56 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
4. The stream will appear between the objects you have connected.
Note: You can also click and release at the outlet port, move the mouse
pointer wherever you like, and then click and release again when you reach
the desired inlet port. There is no need to hold the mouse button down the
entire time.
Rerouting a Stream
Even after you’ve completed your flowsheet and added detailed information about
your streams, you can still reroute a stream if needed. There are two ways to do this.
The first method is to move the existing stream around using its sizing handles.
When you click on a stream to select it, the stream line displays in green, and small
green sizing handles appear. Each stream turn will have a sizing box, as well as each
stream segment. You can click and drag any of these handles to move the adjacent
stream segment(s) to a new location.
If you click a corner sizing handle, you can move the two adjacent stream
segments in any direction; this often affects the position of other stream segments as
well. If you click a sizing handle in the middle of a stream segment, then you can
only move the segment left and right (for a vertical segment) or up and down (for a
horizontal segment).
The second method for rerouting a stream is to re‐draw it entirely. To do this,
click the stream to select it, then right‐click and select Reroute stream. The old
stream disappears, replaced by the beginning of a new stream originating at the
same outlet.
You can now click to create 90° turns, the same way you would with a new
stream, to route the stream exactly where you want it. After a stream is rerouted, it
retains all of the stream detail that you had previously entered.
CHEMCAD Version 7 User Guide 57
Building and Using a Basic Simulation
Stream IDs
When you draw streams on your flowsheet, CHEMCAD assigns each one a stream
ID number that is unique within the simulation. The stream number is an important
identifier for the stream, and is used in various reports and charts as you work with
the simulation.
The stream ID is displayed in a rectangular box, easily distinguishable from the
ovals used to display UnitOp IDs.
Figure 5-10: A stream ID box
When you draw a stream, the ID box is positioned on the longest stream
segment. If you subsequently move the flowsheet objects that contain the stream’s
end points, or otherwise change the path of the stream, the stream ID box will
change its position accordingly.
In some situations, you may want to move a stream ID box from its default
location. To do this, click the stream to highlight it, then move your mouse cursor
over the stream ID box. When you see the cursor change to a curved hand shape,
click and drag the ID box to the desired location.
Figure 5-11: The hand cursor for moving a stream ID box (left) and a stream ID box being moved
If you have manually placed a stream ID box, you might later want to restore it
to its default location on the stream. To do this, simply right‐click the stream or the
ID box and select Reset ID Position. This returns the stream ID box to its automatic
placement on whichever stream segment is currently the longest.
58 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
Stream ID Ranges
By default, your streams will be numbered, starting at 1, in the order in which you
create them. If you want to create a series of streams with a separate range of ID
numbers from the rest of your simulation, you can use the Starting IDs feature to
accomplish this.
Select Format > Starting IDs, which brings up the Stream and UnitOp Starting
IDs dialog box. Then scroll down to the Stream option and click the adjacent number
column. Enter the number that will be the start of your separate stream ID pool, and
click OK. If you later need to draw more streams with ID numbers in the normal
range, you can return to this dialog box and reload the default setting.
For example, to draw a series of utility streams with ID numbers starting at 300,
you would set the stream starting ID option to 300 and draw the streams in question.
Those streams would be numbered 300, 301, 302, and so forth. After drawing all of
your utility streams, you would then set the Stream ID option back to 1, so that the
next new stream in the main flowsheet would be assigned the next available stream
ID from the regular pool of numbers. You can reset the stream option number as
many times as needed while you create and edit your simulation.
Stream Names
In addition to the assigned stream ID, you can give a stream a name, using up to 11
alphanumeric characters. This name appears in the Edit Stream dialog, in the
Streams area of the CHEMCAD Explorer pane, on certain reports, and optionally on
the flowsheet with the stream ID.
To add a stream name, you can open the Edit Streams dialog and type in the
Stream Name field. Another way to add a name is to right‐click the stream and
select Edit Name; type the name in the resulting dialog box and click OK.
By default, a newly added stream name will appear beneath the number in the in
the stream ID box. To hide a single stream’s name, right‐click the stream and clear
the check mark next to Show Name; simply check this menu item again to make the
stream name visible again.
To view or hide all stream names on the flowsheet with a single command, select
View > Flowsheet Settings and choose either Show All Stream Names or Hide All
Stream Names.
Stream Intersections
When streams cross on a flowsheet, a visual indicator can be helpful to show that the
streams do not interact with one another. You can set up a default size and shape to
show one stream “jumping” over another wherever two streams meet. By default, a
stream jump displays as a semicircle.
CHEMCAD offers several other options for stream intersections, including no
jump indicator and a dash to break one stream line as it crosses. The figure below
shows all of the available stream intersection options.
CHEMCAD Version 7 User Guide 59
Building and Using a Basic Simulation
Figure 5-12: Stream intersection options (from left: None, Dash, Triangle, Trapezoid, Square,
and the default setting, Circle
To select a stream intersection option for the current simulation, select Format >
Stream Styles. In the Stream Styles dialog, drop down the Style list under
Intersections, and select an option. When you click OK, any stream intersections
already on your flowsheet will change to the new style; any new intersections that
occur will also use that style. This style will continue to be used for new
intersections, even after this simulation has been closed and re‐opened.
To change the global style for stream intersections—that is, to set the default for
all future simulations created in your CHEMCAD installation—you can change the
setting in a different place. Select Tools > Options > Preferences, then choose Stream
Styles. Here you have the same list of options from which to choose, but when you
select one and click OK, the chosen style will become the default.
You can change the Stream Styles default style at any time, and the Format >
Stream Styles option will always override the global default setting for the current
simulation.
Note that you can also change the size of the stream jumps in both the current
and global settings for stream intersections. The default size is 48, which is well
proportioned for use with standard UnitOp sizes.
Defining Streams
The streams that you have drawn on your flowsheet are still just lines with no data
behind them. The next step is to edit these streams as needed, populating them with
composition data and other properties.
In most situations, the streams you’ll need to define will be the feed streams in
your process. Other types of streams, such as recycle cut streams, may also require
definition.
You can edit a single feed stream using either of these methods:
• Double‐click the stream.
• Right‐click the stream line and select Edit Stream.
• On the Simulation tab in the CHEMCAD Explorer, expand Flowsheet and
then Streams, right‐click the stream in question, and select Edit Stream.
You can edit all feed streams in the flowsheet at once using either of these
methods:
• Select Specifications > Feed Streams.
60 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
• Click the Edit Feed Streams button (just to the left of Component List on the
Setup toolbar).
Whichever method you choose, you’ll see the Edit Streams dialog box, with
either a single column of data or a column for each feed stream in the flowsheet. In
this dialog box, specify properties for each feed stream listed.
Thermodynamic Properties
You must specify exactly two of the following three variables:
• Temperature
• Pressure
• Vapor fraction
CHEMCAD will calculate the third variable and enthalpy, based on the two
variables you specify and the thermodynamics method you’ve selected, once the
stream composition data has been entered.
Note: In the Edit Streams dialog box, the user‐specified values for feed streams will
display in green, differentiating them from calculated values.
Stream Composition
To define the stream composition, you’ll need to specify a composition unit and the
amount of each component that is present in the stream.
Select a unit from the Comp unit drop‐down list, and then based on that
selection, populate the field for each component with the appropriate amount,
percentage, or fraction.
For stream compositions expressed as a percentage or fraction, you can enter
values that do not total 100%. In this case, CHEMCAD will normalize the
composition to fractional values that total 1. To preview the normalized values that
CHEMCAD assigns to the components, click Flash.
CHEMCAD Version 7 User Guide 61
Building and Using a Basic Simulation
Figure 5-13: Two UnitOps that require very different amounts of input
The detailed information about the specifications for each type of UnitOp is
contained in the CHEMCAD Help system, which you can access from any
CHEMCAD screen by pressing the [F1] key.
These specification screens do, however, have certain rules in common:
• Items with green text labels are required entries.
• All other entries are optional.
• Clicking OK saves your specification changes; clicking Cancel discards them.
After you click OK, CHEMCAD checks your data for internal consistency and
then returns errors or warnings as warranted. These items display in the Messages
pane in the CHEMCAD window.
62 CHEMCAD Version 7 User Guide
Building and Using a Basic Simulation
Now that you’ve drawn the flowsheet and added detail to the streams and UnitOps
that make up the flowsheet, you can run the simulation. You can either select Run >
Run Steady State > Run All, or simply click the blue Run All button on the main
CHEMCAD toolbar.
Figure 5-14: The Run All toolbar button
When you run a simulation, CHEMCAD calculates material and energy balances
throughout the entire flowsheet and returns any errors or warnings discovered in
the flowsheet. If the run completes successfully, a Run finished message appears at
the far left of the status bar, at the very bottom of the CHEMCAD window.
For preliminary checks of individual UnitOps or groups of UnitOps, you can
select Run > Run Steady State > Run Selected UnitOps, or right‐click any UnitOp
on the flowsheet and select Run This UnitOp.
Note: CHEMCAD reports, plotting, and plot printing are covered in detail in
Chapter 8, Output and Reports.
CHEMCAD Version 7 User Guide 63
Building and Using a Basic Simulation
64 CHEMCAD Version 7 User Guide
Chapter 6
Using CHEMCAD for High-fidelity Modeling
Unit operation specifications in CHEMCAD vary greatly in detail, from vague and
conceptual to extremely specific and realistic. Depending on the demands of your
process and what you’re trying to achieve with your simulation, you may work with
what we call low‐fidelity modeling, high‐fidelity modeling, or both.
This chapter addresses CHEMCAD’s capacity for high‐fidelity modeling and
how to achieve a high level of realism with your UnitOps.
CHEMCAD Version 7 User Guide 65
Using CHEMCAD for High‐fidelity Modeling
• High‐fidelity: You specify energy and equipment parameters and CHEMCAD
calculates the actual results.
Figure 6-01: The Sizing menu, showing heat exchanger sizing options
Equipment sizing can complement low‐fidelity results, and often provides an
excellent starting point for high‐fidelity modeling. You can use certain sizing results
as input for high‐fidelity models of UnitOps in your simulation. Specifying
geometric parameters for UnitOps can help you obtain more realistic results.
Note that for low‐fidelity modeling, sizing does not change converged flowsheet
results. Also, for some UnitOps, certain geometry parameters must be entered
regardless of the selected calculation mode.
66 CHEMCAD Version 7 User Guide
Using CHEMCAD for High‐fidelity Modeling
Piping
You can use either low‐ or high‐fidelity modeling for piping in your simulation.
Pipeline sizing is done based on the composition of a selected stream.
Low-fidelity
For low‐fidelity modeling of piping, you are required to specify pipe diameter and
length in most modes; design modes that calculate diameter are the obvious
exception to this. The pressure drop through the pipe is calculated based on
diameter, length, and flow rate through the pipe.
Sizing
To perform sizing calculations, select Sizing > Piping. Select one or more streams,
then in the Pipe Sizing dialog box, select a sizing option and click OK for line sizing
results. You can use these results, such as suggested pipe thickness and diameter, to
specify geometry for a Pipe UnitOp, or simply review them for the information you
need.
Note: You can also click to select the relevant stream on the flowsheet (hold down
[SHIFT] to select multiple streams), then right‐click and select Line Sizing to access
the Pipe Sizing dialog box.
Figure 6-02: Line sizing results from the Pipe Sizing dialog box
CHEMCAD Version 7 User Guide 67
Using CHEMCAD for High‐fidelity Modeling
High-fidelity
In high‐fidelity piping models, Pipe UnitOps interact with Node UnitOps to balance
pressure and flow rates hydraulically among connected pieces of flow‐based
equipment. Nodes must be placed on both sides of all Pipe UnitOps to be included
in hydraulic balance; pressure and flow constraints are set at the nodes, not in the
pipes.
A high‐fidelity piping model can show changes in flow rate based on back
pressure where two pipes mix, whereas a low‐fidelity model would simply assign
the lower of two specified pressures to the outlet without consideration for back
pressure.
Low-fidelity
For these equipment types, CHEMCAD calculates power usage and thermal effects
on the fluid, based on specified output pressure or pressure increase. Other
parameters, such as efficiency, are optional but do affect results.
High-fidelity
To produce a high‐fidelity model for these equipment types, you must select the
operation mode in which you specify performance curves—that is, pressure change
as a function of volumetric flow rate. This performance information is generally
available from the equipment vendor. Based on the volumetric flow entering the
UnitOp, CHEMCAD calculates outlet pressure.
As with piping, high‐fidelity modeling for pumps, compressors, and expanders
can be used with nodes as part of a hydraulic flow balanced network.
Low-fidelity
With low‐fidelity modeling of a vessel or tank, a stream enters the Flash UnitOp and
separates into vapor and liquid; CHEMCAD does not consider hold‐up or liquid
level in the tank. If you want to take a steady‐state snapshot of the vessel, you can
manually adjust the flow rate and/or thermal conditions to make volumetric flow
rates match the volume of the vessel.
68 CHEMCAD Version 7 User Guide
Using CHEMCAD for High‐fidelity Modeling
Note: The Batch Tank UnitOp is specifically intended for use with the Batch
Distillation Column UnitOp. It does not represent a standard storage tank for
general purposes.
Sizing
To calculate sizing for a vessel, select a Flash UnitOp and then select Sizing > Vessel.
Choose either LV Vessel (liquid‐vapor vessel) or LLV Vessel (liquid‐liquid‐vapor
vessel), depending on your needs. In the resulting dialog boxes, enter the
appropriate values for your vessel and click OK.
Figure 6-03: Sizing a vessel in CHEMCAD
The results that CHEMCAD returns include basic vessel geometry such as height
and diameter.
You can also perform vessel sizing on a converged distillation column to
calculate geometry for a reflux drum or similar piece of equipment.
High-fidelity
You can perform high‐fidelity modeling only on vessel reactors and dynamic
vessels, and only with a CC‐DYNAMICS license (for dynamic vessels, a CC‐SAFETY
NET license will suffice). If you specify the geometry of your vessel and use
CHEMCAD’s dynamics mode, you can study what happens in the vessel over time
as material is added or withdrawn.
Unlike simple flash vessels, vessel reactors and dynamic vessels do consider
hold‐up, liquid level, and variable pressure over time.
CHEMCAD Version 7 User Guide 69
Using CHEMCAD for High‐fidelity Modeling
Valves
Valve modeling in CHEMCAD can be either low‐fidelity or high‐fidelity. You can
size a control valve based on any flowsheet stream.
Low-fidelity
The Valve UnitOp is used for low‐fidelity modeling of a valve. For this type of
UnitOp, you specify outlet pressure or pressure decrease through the valve.
Sizing
Select Sizing > Control Valve, then select a stream. In the Control Valve Sizing
dialog box, specify the outlet pressure for the theoretical valve, and enter other
specifications as appropriate. When you click OK, CHEMCAD returns information
such as capacity coefficient (Cv) and valve size.
Note: You can also click to select the relevant stream on the flowsheet, then right‐
click and select Control Valve Sizing to access the Control Valve Sizing dialog box.
Figure 6-04: The Control Valve Sizing dialog box
High-fidelity
The CVAL UnitOp is used for high‐fidelity valve modeling. Decide which values
you will provide and which values CHEMCAD will calculate, and select the
appropriate operating mode in the Control Valve dialog box. Provide the valve’s Cv
value, and any other specifications as needed.
Control valves can be used with nodes as part of a hydraulic flow balanced
network.
Columns
Columns in CHEMCAD can be modeled as either low‐fidelity or high‐fidelity. You
can perform sizing on any converged column.
Low-fidelity
For low‐fidelity modeling of columns, use the Tower, Tower Plus, or SCDS UnitOps.
Specify ideal stages and the conditions at the reboiler and condenser, as applicable.
70 CHEMCAD Version 7 User Guide
Using CHEMCAD for High‐fidelity Modeling
A low‐fidelity column model does not consider mass transfer effects or column
internals.
Different column specifications can provide more realism without taking
geometry into account. Specifying top purity is a very low‐fidelity model, while
specifying reflux ratio or condenser duty can bring your results closer to reality.
Sizing
After running your simulation, click the UnitOp representing the distillation column
and select Sizing > Distillation; choose either Trays or Packing, based on the type of
column.
The resulting dialog boxes prompt you to enter information about your trays or
packing and the calculation methods you want to use for column sizing. You will
generally need to enter some geometry and hydraulic parameters to complete
column sizing.
Figure 6-05: Specifying high-level tray data for distillation column sizing
Figure 6-06: Specifying detailed tray data
CHEMCAD Version 7 User Guide 71
Using CHEMCAD for High‐fidelity Modeling
Based on flowsheet values and your sizing input, CHEMCAD returns column
geometry information such as height and diameter. It also provides hydraulic
performance information such as predicted amount of flooding.
High-fidelity
To perform high‐fidelity modeling of a distillation column in steady state, use the
SCDS UnitOp and select either of the mass‐transfer simulation models for the
column.
You will need to specify geometry for the column and choose a calculation
method for the selected mass‐transfer model. CHEMCAD calculates column
performance based on your packing or tray specifications.
For columns, mass transfer‐based modeling performs rigorous non‐equilibrium
mixing of vapor and liquid, whereas low‐fidelity modeling assumes ideal mixing.
To perform high‐fidelity modeling of a distillation column in dynamics, specify
the geometry of the column and details about the control system. This dynamic
distillation can consider column hold‐up and the effect of variables changing over
time.
Note: The Shortcut Column UnitOp is not a rigorous calculation model. Unless your
system satisfies the constant molar underflow assumption, you should consider
using a different type of distillation column.
Heat Exchangers
When specifying a heat exchanger in a simulation, you can use either low‐ or high‐
fidelity modeling as well as sizing, depending on the type of heat exchanger
involved.
Low-fidelity
When creating a simulation, you can use a low‐fidelity approach by simply
specifying the thermal conditions coming out of the exchanger. Specifying heat duty
instead of merely an outlet temperature brings your results closer to reality, but this
approach still doesn’t consider geometry.
Sizing
You can use the CC‐THERM module for rigorous calculation of heat transfer
coefficient (U) based on heat exchanger geometry. In rating mode, CC‐THERM
determines whether the user‐specified heat exchanger is capable of the flowsheet
heat exchanger performance. In design mode, CC‐THERM calculates an exchanger
design that is capable of the flowsheet performance.
High-fidelity
For some exchanger categories—specifically shell‐and‐tube and double‐pipe—you
can use the rigorous CC‐THERM model to calculate heat exchanger performance.
72 CHEMCAD Version 7 User Guide
Using CHEMCAD for High‐fidelity Modeling
The flowsheet results are based on rigorously calculated U value and the specified
exchanger geometry. You can also determine approximate fouling of a unit if actual
outlet temperatures are known.
Figure 6-07: Heat exchanger summary report generated as an Excel worksheet
Relief Devices
For relief devices, sizing is not necessarily distinct from low‐fidelity modeling. To
model dynamic relief of a vessel, you can instead use high‐fidelity modeling.
Low-fidelity
To model a steady‐state snapshot of a relief device, select Sizing > Relief Device,
specify a rating or design mode, and select the appropriate options for your relief
scenario. When you click OK, CHEMCAD returns a relief device calculation
summary.
High-fidelity
If you select the Rigorous integral analysis design method when sizing a relief device,
you will obtain a results based upon the changing latent heat of the liquid as it
changes over time.
CHEMCAD Version 7 User Guide 73
Using CHEMCAD for High‐fidelity Modeling
Figure 6-08: Selecting the rigorous integral analysis method for relief device design
You can also perform high‐fidelity relief device modeling for the Vessel Reactor
and Dynamic Vessel UnitOps. You can specify the relief device nozzle area, as well
as other specifications for your relief scenario. This enables you to study the dynamic
relief of the vessel.
74 CHEMCAD Version 7 User Guide
Chapter 7
Building and Using a Dynamic Simulation
While steady‐state modeling can provide all of the information you need for many
purposes, it’s often informative to look closely at the changes over time that affect
your streams and equipment. CHEMCAD’s CC‐DYNAMICS module makes it
possible to simulate a process over time.
Licensing Considerations
To use the functionality described in this chapter, you must have a valid license for
the CC‐DYNAMICS module of CHEMCAD. To view or change the disposition of
your CC‐DYNAMICS product license, see the CHEMCAD License Monitor screen
(Tools > Options > Licensing when a simulation is open, or License > Licensing
when no simulation is open).
CHEMCAD Version 7 User Guide 75
Building and Using a Dynamic Simulation
If you don’t currently have access to the dynamics features and want to add CC‐
DYNAMICS to your copy of CHEMCAD, contact the person within your
organization who handles software licensing, or if appropriate, you can contact
Chemstations or a CHEMCAD distributor directly. For a complete list of
Chemstations contacts and CHEMCAD distributors for all parts of the globe, see our
website (www.chemstations.com).
76 CHEMCAD Version 7 User Guide
Building and Using a Dynamic Simulation
Switching to Dynamics
To switch to dynamics, first open the simulation. Then select Run > Steady
State/Dynamicss and select Dynamics on the fly‐out menu.
Figure 7-01: Switching to dynamics
After you switch to dynamics, you’ll notice that a few things have changed on
the CHEMCAD screen:
• The status bar at the bottom of the main CHEMCAD window changes. A few
inches from the right edge of the screen, instead of the words Steady State,
you’ll now see DTime and a time counter displaying the number of minutes
your simulation has run. Before you run the simulation, the DTime setting
displays 0:00 min.
CHEMCAD Version 7 User Guide 77
Building and Using a Dynamic Simulation
• The steady‐state Run All button on the toolbar is disabled, and the dynamics
buttons are now activated. These buttons, shown in Figure 7‐02, are (left to
right) Set Run Time, Reset to Initial State, Run Dynamic Simulation, Plot
Dyn Streams, and Plot Dyn UnitOps.
Figure 7-02: Toolbar buttons for dynamics
• You can now select Run > Run Dynamics to view a submenu that provides
convenient access to all dynamics settings and commands.
Figure 7-03: The Run Dynamics submenu
78 CHEMCAD Version 7 User Guide
Building and Using a Dynamic Simulation
1. Select Run > Run Dynamics > Set Run Time, or click the Set Run Time
button on the toolbar. This brings up the Dynamic Run Time Schedule dialog
box.
Figure 7-04: The General tab on the Dynamic Run Time Schedule dialog box
2. On the General tab, set the number of operation steps you plan to use, or
leave the default setting of 1. The maximum number of steps that you can
specify is 10.
Note: When you initially set up dynamics for a simulation, the Current time display
field on this tab will be empty. After the simulation has run, this field displays the
total time of a completed run, or the current time of an interrupted run.
3. Now click the Step 1 tab and specify the parameters for this portion of the
dynamic run. Enter the total time for this dynamic step in the Run time field,
and the interval in minutes in the Step size field.
Figure 7-05: The Step 1 tab on the Dynamic Run Time Schedule dialog box
4. If you have other steps to specify, click each tab in turn and enter the Run
time and Step size information.
5. When you have specified all steps, click OK to return to the main
CHEMCAD workspace.
The Dynamic Run Time Schedule dialog box also allows for conditions other
than time to determine the duration of a dynamic operation step. If you select
Stream or Equipment instead of the default Time option, you can specify a stream
CHEMCAD Version 7 User Guide 79
Building and Using a Dynamic Simulation
or UnitOp parameter that will trigger the end of this step, if that parameter is
reached before the step’s run time is up.
Figure 7-06: The Record Streams dialog box
3. When you have selected all the streams you want to record, click OK to
return to the main workspace.
4. Now select Run > Run Dynamics > Record UnitOps. In the Record UnitOps
dialog box, select UnitOps in the same way that you selected streams in step
2.
5. Click OK to return to the main CHEMCAD workspace.
Note: In both the Record Streams and Record UnitOps dialog boxes, you can use the
RunTimePlot check boxes to include selected items in a real‐time plot. Selecting
items for runtime plotting leads to another dialog box (either Dynamic Stream Plot
Options or Dynamic Equipment Plot Options), where you can select plot specifics for
each stream or UnitOp. It is recommended that you use runtime plotting in
moderation, as too many streams and UnitOps can become visually confusing and
slow down calculations considerably.
80 CHEMCAD Version 7 User Guide
Building and Using a Dynamic Simulation
Note: At any point during a dynamic run, you can press the [ESC] key on your
keyboard to stop the run after the current calculation. When you do this, you will see
a Program interrupted message. Click OK to close the message box, and then either
inspect your run results or select a run command to continue.
CHEMCAD Version 7 User Guide 81
Building and Using a Dynamic Simulation
Figure 7-07: The Convergence Parameters setting for running one step at a time
Figure 7-08: A UnitOp specification dialog box after a dynamic run
82 CHEMCAD Version 7 User Guide
Building and Using a Dynamic Simulation
To return the simulation to its initial state—also known as time zero—select Run >
Run Dynamics > Reset to Initial State, or use the Reset to Initial State button on the
main CHEMCAD toolbar.
Note: An advanced feature to allow specification editing at any time is available, but
should be used with extreme caution to avoid confusion and unintended results.
This feature is controlled by a check box on the Convergence Parameters dialog box.
CHEMCAD Version 7 User Guide 83
Building and Using a Dynamic Simulation
After running a dynamic simulation, you can view the data behind any
flowsheet stream or UnitOp to see the effects of the run calculations. Double‐click
any stream or UnitOp on the flowsheet to review its end‐of‐run values.
You can also stop to review flowsheet data in the middle of a run, either by using
the Run one time step for dynamic simulation option or by pressing [ESC] to pause
a run. Once the run has stopped, you can double‐click any stream or UnitOp to
review its current values.
Note: For the Stream History and Dynamic UnitOp History plots, be sure to record
the streams and UnitOps that you want to study. You can only request these plots
for recorded streams or UnitOps.
• Dynamic Stream History: This report provides stream histories for a specific
stream that you select, based on the interval that you specify and including
the compositions, components, and stream properties that you select.
• Dynamic UnitOp History: This report provides detailed information about a
dynamic UnitOp in the simulation, based on the interval that you specify and
including the UnitOp parameters that you select.
Note: For the Dynamic Stream History and Dynamic UnitOp History reports, be sure
to record the streams and UnitOps that you want to study. You can only request
these reports for recorded streams or UnitOps.
CHEMCAD Version 7 User Guide 85
Building and Using a Dynamic Simulation
86 CHEMCAD Version 7 User Guide
Chapter 8
Output and Reports
One of CHEMCAD’s greatest strengths is its capacity to provide detailed,
customized information about equipment, streams, and processes. The program can
display a customizable snapshot of current data for any stream or UnitOp at any
time. You can also create custom reports, spec sheets, and databoxes for process flow
diagrams, and you can plot or print any of these items in the most appropriate
format.
Text Reports
CHEMCAD can produce a wide array of customizable text‐based simulation reports,
based on stream data, UnitOp data, flowsheet data, or dynamics. If you prefer, you
can produce one consolidated report incorporating any combination of the available
text report data.
CHEMCAD Version 7 User Guide 87
Output and Reports
• Microsoft WordPad
• CSV format
By default, CHEMCAD uses the internal report viewer. To switch to another
format, select Tools > Options > Preferences, then select Report Viewer. Click the
Default Report Viewer drop‐down box, and select your preferred program from the
list. Click OK to save your choice and return to the main CHEMCAD workspace.
Note: While in the Report Viewer settings, you may want to change the setting
called Date/Time Location, which controls where on the page the date and time
information appears on reports. The default setting is Footer, but you can select
Header instead, if you prefer.
For the consolidated report, you can choose from the same list of programs. To
select a program to display and print this type of report, select Report >
Consolidated Report, then click the Destination drop‐down box. Make your
selection and then continue customizing your report; when you finish and click
Generate, the report will display in the program you selected.
Property Sets
CHEMCAD calculates and stores a large number of data points about the process
streams in your simulations. Some of these items will be of great interest to you,
while others may be useful only in rare situations. A customization feature called
property sets enables you to choose exactly what information to display about your
process streams in the various types of reports.
A property set is a collection of physical data to display about a stream (or a
group of streams). It could include very few items—for example, only temperature
and pressure—or it could show in‐depth details about the stream and all of its
components. For every type of text report in CHEMCAD, you can choose a property
set that best fits your needs.
88 CHEMCAD Version 7 User Guide
Output and Reports
Figure 8-01: Menu flyout showing the active property set for Quickview reports
In the list of all available property sets, the set which is currently active for that
report type will appear with a check mark. To make a different property set active
for that report type, simply click the set’s name in the list.
CHEMCAD Version 7 User Guide 89
Output and Reports
Figure 8-02: The Property Set Preferences dialog box, as accessed from Report > Quickview >
Customize Property Sets
90 CHEMCAD Version 7 User Guide
Output and Reports
To change the order of items in the property list, use the Up and Down buttons
at the bottom of the right‐hand column. Simply select any first‐ or second‐level item
on the Properties tab and click either Up or Down to give that item a new place in
the list of properties. All selected properties will display in reports according to the
order you choose here.
Clicking OK saves all changes that you have made to property sets since opening
the Property Stream Preferences dialog.
Figure 8-03: Expanding a first-level item to view a list of properties
Note that when you check the box by a first‐level item, you select all of the items
in that category. Similarly, clearing a first‐level box removes all of its second‐level
items from the property set. A solid blue check box indicates that some, but not all,
second‐level items are currently checked.
Figure 8-04: Property categories with no options selected (left), all options selected, and mixed
selections
As with editing a property set, use the Up and Down buttons to move properties
into the desired order, and click OK when you have finished to save your changes.
CHEMCAD Version 7 User Guide 91
Output and Reports
92 CHEMCAD Version 7 User Guide
Output and Reports
Figure 8-05: The Property Set Library dialog, showing built-in and custom property sets
The left side of this dialog lists local property sets—that is, all property sets that
are available in the current simulation. This includes the three built‐in property sets
(Quickview, Stream Composition, and Stream Property), plus any sets you have
created in the current simulation.
If you want to make a custom property set available in the future for simulations
that you open on this installation of CHEMCAD, add the set to the Library Sets list
on the right.
To do this, select the desired set in the Local Simulation Sets list on the left side of
the screen, then click the right arrow between the two lists. The selected set will now
appear under Library Sets, with the designation (Copy) at the end of the set name.
Figure 8-06: Before and after copying a property set to the Library Sets list
It’s recommended that you give the library copy of the property set a unique
name, to avoid confusion. When you have finished, click OK to return to Property
Set Preferences, and OK again to return to the CHEMCAD workspace.
CHEMCAD Version 7 User Guide 93
Output and Reports
Note: Changes to the Library Sets list will be saved after you click OK, even if
you then close the simulation without saving it. You must save the simulation
file, however, to keep any changes you have made to the Local Simulation Sets
list.
The Library Sets list works as a global repository for a given CHEMCAD
installation. Once a property set is designated as a library set, it is available to use in
any new or existing simulation.
a. When you create a new simulation, all library sets will automatically appear
in the local list of stream property sets.
b. For an existing simulation, open the Property Set Library dialog box, select
the desired property set in the right column, and click the left arrow to copy
it to the left column.
Stream-based Reports
CHEMCAD offers several types of reports to help you analyze stream data. These
reports can be accessed in various ways: using the main Report menu, turning on
the Stream Quickview feature, clicking specialized toolbar buttons, and using the
stream right‐click menu.
The content of stream reports is controlled by property sets, as described in the
previous section. You can use the built‐in property sets, customize those sets, or
create your own sets—and you can choose which set to use at any time, or for any
type of report.
Stream Report
Before you run a stream properties report, confirm that the property set you want to
use is currently linked to this type of report. To do this, select Report > Stream
Reports > Select Active Property Set. The checked item in the flyout menu is the
active property set for stream properties reporting. To set a different property set as
94 CHEMCAD Version 7 User Guide
Output and Reports
active for this type of report, simply click the set’s name so that the check mark
appears next to it.
Figure 8-07: Checking the active property set for Stream Reports
Now that the desired property set is active, select Report > Stream Reports and
then choose from the following options:
• Select Streams: Choose the streams you want to include in the Select Streams
dialog box, either by typing in the stream numbers (one per line) or by
clicking on streams in the flowsheet. Click OK to close the dialog box and
display the report.
• All Streams: This report displays stream property data for every stream on
the flowsheet.
• Feed Streams: This report displays stream property data only for streams
issuing from a Feed icon on the flowsheet.
• Product Streams: This report displays stream property data only for streams
terminating in a Product icon on the flowsheet.
• Unit Streams: This report displays property data for all inlet and outlet
streams connected to a specified UnitOp on the flowsheet. If no UnitOp icon
is selected when you run the report, you’ll see the Select UnitOps dialog box;
type the UnitOp ID or click the UnitOp on the flowsheet and then click OK to
display the data. If you select a UnitOp icon before running the report, the
data will display without further input.
Note: You can also select any available property set to generate a stream report from
the flowsheet. To do this, click the applicable stream (or [SHIFT]‐click to select
multiple streams), then right‐click to bring up the stream menu. Select Stream
Reports and then choose a property set from the menu flyout to generate the stream
report.
CHEMCAD Version 7 User Guide 95
Output and Reports
distribution exists (one per line), either by typing in stream numbers (one per line) or
by clicking on streams in the flowsheet. Click OK to display the report.
Pseudocomponent Curves
For a text report on pseudocomponent curves (also known as distillation curves),
select Report > Pseudocomponent Curves. Select one or more streams containing
hydrocarbons, either by typing in stream numbers (one per line) or by clicking on
streams in the flowsheet. Click OK to display the report.
Stream Groups
For stream composition and property reports, you can create custom stream groups
within a simulation to streamline your report requests.
For example, if you have a process that involves ten different utility streams, and
you frequently run reports on this group of streams, you can set up a group
consisting of just those streams. Then, whenever you want to obtain composition or
property data for those streams, you’re just a few clicks away anytime the simulation
is open.
The quickest way to set up any group is to use the CHEMCAD Explorer. Follow
these steps to create a stream group:
1. In the CHEMCAD Explorer pane, find the top‐level item called Groups. Click
the plus sign next to Groups to expand this item.
Figure 8-08: Expanding the Groups item in CHEMCAD Explorer
2. Now click the Streams item under Groups, to bring up the New Group
dialog. Replace the default name (such as Group 1) with a descriptive name
for your group, then click OK.
96 CHEMCAD Version 7 User Guide
Output and Reports
Figure 8-09: Naming the new stream group
3. In the Edit Stream Group dialog box, select the streams for this group, either
by typing in the stream numbers (one per line) or by clicking on streams in
the flowsheet. Click OK to close the dialog box.
4. As soon as you finish creating the group, its name appears under Streams in
the Groups area of the CHEMCAD Explorer. From here, you can right‐click
the group name and select any of the following:
• View/Edit: Open the Edit Stream Group dialog box, where you can add
or delete stream numbers to include in the group.
• Select Streams: Highlight the group’s streams on the flowsheet.
• Rename: Open the Rename Group dialog box, where you can type a new
name for the stream group.
• Copy: Open the Copy Group dialog box, where you can type a new
group name to make an exact copy of the stream group. After you click
OK, you can then edit the new copy of the group to fit your needs.
• Delete: Remove this stream group from the simulation. If you’re sure
about deleting the group, click Yes in the dialog box that appears.
• Composition: Run a stream composition report for the streams in the
group, using the Stream Composition property set.
• Properties: Run a stream properties report for the streams in the group,
using the currently active Stream Reports property set.
Note: The commands to create, view, edit, and remove stream groups are also
offered on the Report menu, under Stream Reports.
UnitOp-based Reports
CHEMCAD can also run reports to analyze UnitOp data. To access these reports,
select the appropriate item from the Report menu. The results will display in either
WordPad or Excel, depending on how you’ve configured CHEMCAD to handle text
reports.
Select UnitOps
To run a report that covers just the Unit Ops you specify, select Report > UnitOps >
Select UnitOps. In the Select UnitOps dialog box, specify the UnitOps you want to
CHEMCAD Version 7 User Guide 97
Output and Reports
include in the report, either by typing in the UnitOp ID s(one per line) or by clicking
on UnitOps in the flowsheet. Click OK to close the dialog box and display the report.
If you select a UnitOp icon before running the report, the data will display
without further input.
Spec Sheet
This command exports detailed information about a UnitOp into a preformatted
Excel worksheet. This report is useful for tasks such as soliciting a manufacturing
quote for a piece of equipment.
• To create a spec sheet for all UnitOps on the flowsheet, select Report > Spec
Sheet > All Units.
• To create a spec sheet only for specific UnitOps, select Report > Spec Sheet >
Select Unit. Choose the UnitOps you want to include in the Select UnitOps
dialog box, either by typing in the UnitOp IDs (one per line) or by clicking on
UnitOp icons in the flowsheet. Click OK to close the dialog box and display
the spec sheet.
• For a single UnitOp spec sheet, you can select the UnitOp icon before
running the report; Excel will open and the data will display without further
input.
Note: For spec sheets that include multiple UnitOps, CHEMCAD creates a separate
worksheet for each UnitOp’s data within the Excel file that CHEMCAD creates.
Distillation
To run a distillation report, select Report > Distillation and then select one of the
following:
• Column Profiles: Generates a report detailing temperature, pressure, and
flow rate for a distillation column
• Tray Compositions: Creates a report that shows the vapor flow rate, liquid
flow rate, and K‐value of each component on each stage of a distillation
column
• Tray Properties: Reports on currently selected stream properties for each
stage of a distillation column
• Tower Mass Transfer (SCDS): For an SCDS distillation column that uses a
mass transfer model, provides mass transfer coefficients, height of transfer
units, and estimated height of theoretical plates (HETP)
• Dynamic Column History: Provides data from a single dynamic run of a
column (described in detail in Chapter 7, Building and Using a Dynamic
Simulation)
98 CHEMCAD Version 7 User Guide
Output and Reports
• Column Diagnosis: For columns that have not successfully converged,
provides recommendations for changing column settings to achieve
convergence
UnitOp Groups
For UnitOp reporting, you can create custom UnitOp groups within a simulation.
Much like their stream‐based counterparts, UnitOp groups can save you time and
effort when requesting reports; in addition, you can use these groups when running
your simulation, to isolate and run only selected UnitOps for diagnostic or other
reasons.
Note: Because of this other functionality of UnitOp groups, the order in which you
list UnitOp IDs when setting up these groups is important.
The quickest way to set up any group is to use the CHEMCAD Explorer. Follow
these steps to create a UnitOp group:
1. In the CHEMCAD Explorer pane, under Groups, right‐click the UnitOps
item and select New.
2. In the New Group dialog box, replace the default name (such as Group 1)
with a descriptive name for your UnitOp group and then click OK.
Figure 8-10: Naming the new UnitOp group
3. In the Edit UnitOp Sequence Group dialog box, select the UnitOps for this
group, either by typing in the UnitOp IDs (one per line) or by clicking on
UnitOp icons in the flowsheet. Add UnitOps in the order they run in the
simulation. Click OK to close the dialog box.
As soon as you finish creating the group, its name appears under UnitOps in the
CHEMCAD Explorer. From here, you can right‐click the group name and select any
of the following:
• View/Edit: Open the Edit UnitOp Sequence Group dialog box, where you
can add or delete Unit Ops or reorder the existing list.
• Rename: Open the Rename Group dialog box, where you can type a new
name for the group.
• Copy: Open the Copy Group dialog box, where you can type a new group
name to make an exact copy of the UnitOp group. After you click OK, you
can then edit the new copy of the group to fit your needs.
CHEMCAD Version 7 User Guide 99
Output and Reports
• Delete: Remove this UnitOp group from the simulation. If you’re sure about
deleting the group, click Yes in the dialog box that appears.
• Run: Run the simulation only for those UnitOps included in this group.
• View: Display a summary report of the UnitOps included in this group.
• Specifications: Bring up the UnitOp specification dialog boxes for each item
in the UnitOp group, starting with the first UnitOp listed.
Note: The commands to add, edit, and remove UnitOp groups are also offered on the
Report menu under UnitOps.
Flowsheet-based Reports
In addition to reports that focus on particular UnitOps and streams, CHEMCAD
offers text reports that provide information about the simulation as a whole. To
access any of these reports, select the appropriate item from the Report menu.
Topology
This report provides a listing of all UnitOps in the flowsheet, as well as all stream
origins and destinations.
Thermodynamics
This report lists all components used in the simulation and provides vital
information about the thermodynamics methods used.
Dynamics Reports
The Report menu provides access to the Batch Results and Dynamics commands,
which provide reports about non‐steady‐stream processes.
Batch Results
This report summarizes the results of a batch distillation column simulation at the
end of each operating step.
Dynamics
You can access three different reports by selecting Report > Dynamics: Dynamic
Column History, Dynamic Stream History, and Dynamic UnitOp History. These
reports are described in detail in Chapter 7, Building and Using a Dynamic Simulation.
100 CHEMCAD Version 7 User Guide
Output and Reports
Figure 8-11: The CHEMCAD Report Writer
From here, you can click Generate to bring up a default consolidated report that
includes topology, convergence, mass and energy balances, and the other reports
listed in the dialog box’s left column. If this report is adequate to your needs, simply
click Return to CHEMCAD after generating the consolidated report, to close the
Report Writer dialog box.
If you want something other than the default consolidated report, you can also
use the Report Writer to customize which individual reports to include, what order
to put them in, which flowsheet elements to include, and much more. You can fine‐
tune your report settings without closing this dialog box, and then save your report
configuration with a new name so that you can run it again in the future.
CHEMCAD Version 7 User Guide 101
Output and Reports
• Remove a section by selecting it in the Current Report Sections list and then
clicking Delete.
• Move a section to a different position within the Consolidated Report by
selecting it in the Current Report Sections list and then clicking the Up or
Down button as needed.
If you prefer to build the section list yourself, you should access the Report
Writer by selecting Report > New from the main CHEMCAD menu. This brings up
the Report Writer screen with a blank left column, ready for you to add just the
report sections that you want in whatever order you choose.
102 CHEMCAD Version 7 User Guide
Output and Reports
Figure 8-12: Typing a new name into the Report Name field
Once you have named the report, you can click Save to save the report locally
(that is, only for this simulation), or click Save As to save the report under My
Simulations\My Reports\Global Reports. Saving in the Global Reports directory
makes the report available to any simulation you may open in the future.
To generate a report that you have saved locally, select Report > Simulation
Reports; select the report by name and click Generate Report. Other options here are
Edit to open the report in the Report Writer, Export to copy it to a global location, or
Delete to remove it from the menu.
CHEMCAD Version 7 User Guide 103
Output and Reports
Figure 8-13: Generating a report that has been saved locally
Note that to generate or access a globally‐saved report, you can select Report >
Global/Pool Reports.
Graphical Reports
In addition to text‐based reports, CHEMCAD offers a wide variety of graphical plots
that you can view onscreen or print for review.
TPXY
This selection generates vapor‐liquid equilibrium curves between any two
components, with an optional third component. You can include TPXY, TXY, activity
coefficient, and fugacity coefficient curves.
Binary LLE
This selection generates liquid‐liquid equilibrium curves between any two
components.
Binodal Plot
This selection generates a ternary phase diagram showing the distribution of three
selected components in two liquid phases, including tie lines and plait point.
Binodal/Residue Curves
This selection creates a plot that combines the curves from a binodal plot and a
residue curve plot. This is useful when working with heterogeneous azeotropic
distillation.
Residue Curves
This selection generates and plots a graphical display of distillation zones,
azeotropes, and residue curves associated with a user‐specified ternary mixture.
104 CHEMCAD Version 7 User Guide
Output and Reports
Flowsheet-based Graphs
To view graphical reports that reflect your overall simulation, select one of the
following from the Plot menu:
• Stream Properties: Plots one selected stream property for a selected stream in
the flowsheet
• Phase Envelopes: Plots a phase envelope for a given stream, highlighting the
critical point of the mixture; can include plots at vapor fractions other than 0
(bubble point curve) and 1 (dew point curve)
• Composite Curves: Plots composite heat curves for the entire flowsheet, as
well as optional heat curves for individual UnitOps
• Pseudocomponent Curves: Displays a plot of one or more distillation curves
for a stream
UnitOp-based Plots
CHEMCAD offers several plots that display data for a single UnitOp. To access any
of these plots, select Plot > UnitOp Plots and then select one of the following
options.
Column Profiles
This selection plots compositions, temperature, and flow profiles for distillation
columns.
Heat Curves
This selection plots heating and cooling curves for a selected heat exchanger.
Pipe Profile
This selection plots fluid properties for pipe UnitOps along the axial length of the
pipe. This plot requires that the pipe contain multiple segments.
Controller Convergence
For controllers that have not converged, this plot enables you to diagnose the
controller behavior that is preventing convergence. The plot shows how the
controller error function changes with iteration.
CHEMCAD Version 7 User Guide 105
Output and Reports
Dynamic Plots
CHEMCAD offers a series of plots for use with dynamic operations. Select Plot >
Dynamic Plots to access any of six graphical dynamics reports.
These plots are described in detail in Chapter 7, Building and Using a Dynamic
Simulation.
User-specified File
If you have customized CHEMCAD using VBA, C++, or other programming
languages, you can save plot data into a text file and use this feature to display that
data as a curve.
Select Plot > User Specified File to bring up a message box that provides
instructions on how to format the text file. Click OK to continue to an Open dialog
box, where you can select the text file you want to use. When you click Open, the
curve is plotted and displayed.
Flowsheet Databoxes
CHEMCAD offers four types of databoxes:
• Stream Box: Lists the streams that you select in a single table, along with the
stream properties that you choose to include
• UnitOp Box: Generates a separate databox for each selected UnitOp
• TP Box: Generates separate summary databoxes for selected streams
• Excel Range Box: References a range of cells from an Excel worksheet
106 CHEMCAD Version 7 User Guide
Output and Reports
Stream Boxes
To create a stream databox, start by selecting Format > Add Stream Box. The flyout
menu offers the same options as you saw for running a Stream Properties report:
Select Streams, All Streams, Feed Streams, Product Streams, and Unit Streams.
After you have selected the streams to include, the Select a Property Set dialog
box displays. The property set you choose here (along with any changes you make to
that property set) determines which properties are included in the resulting stream
databox.
Figure 8-14: The Select a Property Set dialog box
In this standard property selection dialog, you can add, copy, or edit a property
set, or simply select an existing set from the list at left. When you click OK, the
stream databox with the selected streams and properties appears on the flowsheet.
Once you have created a stream databox, you can move, stretch, or resize it using
your mouse. You can also edit the contents of the databox by right‐clicking the box
and selecting Edit Databox.
CHEMCAD Version 7 User Guide 107
Output and Reports
Figure 8-15: Using the Edit Databox command to change stream box contents
This brings up a property selection dialog much like the one you used to create
the databox, with the title Select New Set or Edit Current Databox Set. Simply add or
delete properties here as appropriate, then click OK to return to the flowsheet and
see your stream databox updated.
UnitOp Boxes
To create a UnitOp databox, simply select Format > Add UnitOp Box, and then
either enter UnitOp IDs in the Select UnitOps box click on the UnitOp symbols on
the flowsheet. To include all UnitOps, click anywhere in the workspace and then
press [CTRL‐A].
When you complete your selections and click OK, the UnitOp databox appears
on the flowsheet.
TP Boxes
CHEMCAD can create databoxes called TP boxes that display any combination of
temperature, pressure, and flow rate for all streams or selected streams on a
flowsheet.
To add TP databoxes, select Format > Add TP Box. In the TP Box Settings dialog
box, first select an option at the top, to determine whether to add TP boxes for all
streams or only for the streams you select.
In the Display column, select items from the drop‐down list in each field to
determine which stream properties to display and in what order. Use No selection
as appropriate if you want to display fewer than four properties.
In the Number format column, make a selection in each field to determine how
numbers will display in the TP boxes. In the Digits column, type the number of
digits to display after the decimal point. You can also choose whether to display
stream IDs (enabled by default) and engineering units.
108 CHEMCAD Version 7 User Guide
Output and Reports
The Preview box displays a dynamic sample of how the items you’ve selected
will appear in the TP boxes. Note that the preview area does not reflect any changes
you may have made to your default font size or style.
When you finish making your selections in the TP Box Settings dialog box, click
OK. If you’ve chosen to make TP boxes for all streams, the TP boxes will appear on
the flowsheet right away. If you’ve opted to select the streams from the flowsheet,
you’ll see a Select Streams dialog box; type the stream numbers (one per line) or click
on the stream lines in the flowsheet to select streams, and then click OK to create the
TP boxes.
Figure 8-16: TP boxes added to a simple flowsheet
CHEMCAD Version 7 User Guide 109
Output and Reports
An Excel range box is a dynamic link between CHEMCAD and the Excel
worksheet. As data is updated and saved in the selected cell range, the range box can
automatically update to reflect those changes. To view the most up‐to‐date data in
your Excel range boxes at any time, select View > Refresh Data Boxes.
110 CHEMCAD Version 7 User Guide
Chapter 9
Customizing CHEMCAD
As you become more familiar with the way that CHEMCAD works and the various
options and tools that are available, you may want to make your own additions—
either for specialized items or for those you use frequently. You can customize
CHEMCAD in several ways that save you time by streamlining and simplifying
your workflow. These include:
• Creating and using stream and UnitOp templates
• Adding custom components to CHEMCAD’s component database
• Defining custom thermophysical rules
• Making your own UnitOp symbols to add to existing or custom palettes
• Building custom UnitOps
• Creating custom dialog boxes for UnitOp settings
• Customizing costing calculations
This chapter discusses all of these types of customization, starting with the
simplest procedures and then moving on to more complex customizations that
require some programming experience.
Flowsheet Templates
One of the most effective ways to save time when creating CHEMCAD simulations
is to make use of stream and UnitOp templates. A template is simply a set of
characteristics, which you assign a name and save for later use. When you set up
stream or UnitOp specifications that you know you’ll need to recreate in the future,
you can create a template of that stream or UnitOp. You can then duplicate that item
CHEMCAD Version 7 User Guide 111
Customizing CHEMCAD
within the same simulation—or in any other simulation—with just a few mouse
clicks.
Creating a Template
To create a stream template, first create the stream you want to clone and give it all
of the characteristics you want to include in the template.
Then find this stream on the CHEMCAD Explorer’s Simulation tab. Expand the
Flowsheet item, then expand the Streams item, and finally double‐click the
applicable stream ID. This brings up an item called Save. Double‐click the word
Save to bring up the Enter Template Name dialog box, then type a name for your
new stream template and click OK. The new stream name is now listed beneath the
Save item.
To create a UnitOp template, select the appropriate UnitOp ID in CHEMCAD
Explorer, and then follow the same procedure used to create a stream template.
Applying a Template
To apply a stream template, first expand the CHEMCAD Explorer item for the
stream to be affected, either by clicking the plus sign to its left or by double‐clicking
the stream name.
When the stream item is expanded, you’ll see the Save item below it, followed by
the names of all the stream templates that you have created. Double‐click the name
of the template you want to apply, then click OK to confirm that you want to apply
this stream template.
Use the same procedure for a UnitOp template, selecting the UnitOp to be
affected and then expanding it in the Explorer to apply the template.
112 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
Click OK to confirm that you want to delete this template. The template name
disappears from CHEMCAD Explorer, but streams or UnitOps that were specified
using the template are not affected in any way.
Note: Any stream or UnitOp template that you create is available for use with all
other simulations on the same installation of CHEMCAD, until and unless you
delete the template.
CHEMCAD Version 7 User Guide 113
Customizing CHEMCAD
The procedure for creating a pure component is as follows:
1. Select Thermophysical > Component Database > Create New Component.
This brings up the New Component dialog box.
Figure 9-01: The New Component dialog box
2. Give the new component a descriptive name; it is strongly recommended that
you make this name unique. All other characteristics here are optional, except
for normal boiling point, which is required for the pseudocomponent
method.
3. Select a Correlation option to indicate which of the above methods you will
use, and click OK to continue.
4. The dialog box that appears next depends on the Correlation that you
selected:
• Pseudocomponent brings up the Hydrocarbon Correlation dialog box.
• Group contribution – Joback brings up the Group Assignments dialog box.
• Group contribution – UNIFAC brings up the New Component UNIFAC
Groups dialog box.
• Combustion solid brings up the Combustion Solid dialog box.
• Electrolyte brings up the Electrolyte Data dialog box.
Select the appropriate options for your new component and specify as many
characteristics as you like, as accurately as possible. Click OK to continue.
5. In the Select Destination Database dialog box, you will see no databases listed
if this is your first time to add a component. If this is the case, click New to
bring up the Manage Component Databases dialog box.
114 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
Figure 9-02: The Manage Component Databases dialog box
6. Normally, you’ll need to click Create, which brings up the Save As dialog
box. Navigate to the location you want for your custom component database,
give the database a name, and click Save. If you want to add a database that
someone else has created (generally in a network location), you can click
Connect, which brings up an Open dialog box; navigate to that database’s
location, highlight the database, and click Open.
7. The Manage Component Databases dialog box now lists the database that
you created or selected. Click OK to continue.
8. In the Select Destination Database dialog box, the new database you have just
named is now listed; highlight it and click OK.
9. The View/Edit Component Data menu now appears. Click any item on the
menu to access a dialog box with options for defining your new component.
After defining as many characteristics as possible, click Exit to close the
menu.
The new component is now available to add to your current simulation and all
future simulations. To return at any time to make changes to a user‐defined
component, do one of the following:
• Select Thermophysical > Component Database > View/Edit Database
Component to bring up the Select Single Component dialog box, which lists
all available components. Highlight the component you want in the list and
click OK to bring up the View/Edit Component Data menu.
• Click Component List on the toolbar (or select Thermophysical >
Component Database > View/Edit Simulation Component) to bring up the
list of components in the current simulation. Double‐click the component you
want in the list to bring up the View/Edit Component Data menu.
CHEMCAD Version 7 User Guide 115
Customizing CHEMCAD
Figure 9-03: The Select Regression Data Set dialog box
2. Select the user‐added component that you want to regress and click New.
This brings up the Edit Regression Set dialog box.
Figure 9-04: The Edit Regression Set dialog box
116 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
3. Select a regression type and provide a descriptive name for the data
regression, then click OK. This brings up a dialog box that displays
parameters for the selected regression type.
4. Verify the data on this dialog box, making additions or changes as necessary,
and then click OK. This brings up a dialog box for data entry.
5. Enter your experiential data points in the cells provided. You can enter a
value in the Weight_factor column to weight the regression toward one or
more data points. When you have entered all of your data points, click OK.
Note: You can paste a contiguous range of cells from an Excel worksheet into the
cells in this dialog box.
6. The regression data is displayed in a tab in the main CHEMCAD window.
Another tab displays the regression results in graphical format. Review the
data and plot, and decide whether the regression adequately represents your
experimental data.
7. A dialog box appears, asking how you would like the changes to be applied
to existing simulations. Choose an option and then click OK.
8. Repeat this procedure as needed to regress other properties for your
component.
Pseudocomponent Range
Using a pseudocomponent curve—another term for the distillation curve portion of an
assay—you can cut a hydrocarbon stream into pseudocomponents, or fractions. A
pseudocomponent represents a group of components that boil within a narrow
temperature range. Pseudocomponent ranges are used in CHEMCAD to model
hydrocarbons.
When you define a pseudocomponent range for a stream, CHEMCAD creates
entries in the component database for each hydrocarbon cut, and assigns these
components’ compositions to the stream.
Note: Before you define a pseudocomponent range, make sure that you have
specified in your component list, as appropriate, water and any light ends that exist
in the assay.
1. Select Thermophysical > Pseudocomponent Curves.
2. In the Dist Curve Characterization dialog box, enter stream number(s) and
click OK.
3. In the Hydrocarbon Correlation dialog box, select the appropriate
correlations for your curve, or use the default selections and click OK.
4. This brings up the Curve Temperature Cut Ranges dialog box. For each cut
range that you want to define, provide a beginning and ending temperature,
CHEMCAD Version 7 User Guide 117
Customizing CHEMCAD
and enter the number of points that you want to define as discrete
pseudocomponents within that range. Click OK to continue.
5. In the Bulk Properties dialog box, specify a distillation curve type and enter a
total flow rate and bulk gravity for the stream. You can make other entries
here as needed, but only these three items are required. Note that if you have
viscosity data that you want to use, you must check the Viscosity box here.
Click OK to continue.
6. In the resulting dialog box, enter the distillation curve from your assay,
specifying the volume percentage and boiling temperature for at least five
data points. Click OK to continue.
7. The next dialog box is optional. Enter a gravity curve from your assay, listing
the volume percentage and specific gravity for at least five data points. Click
OK to continue.
8. The next dialog box is also optional. If you have light ends and water defined
in your assay, enter volume percentage data here for all relevant components.
Click OK to continue.
9. If you checked the Viscosity box on the Bulk Properties dialog, you will now
see the Viscosity Data dialog box. Enter your viscosity data and click OK.
10. This brings up the Edit Distillation Curves menu, shown in Figure 9‐05.
Figure 9-05: The Edit Distillation Curves menu
11. Click Save and Exit. The pseudocomponent properties now display in a tab
in the main CHEMCAD window. You can review and print these results, and
leave the tab open as long as you like. To return to the main workspace and
your flowsheet, simply click the far left tab, which displays the name of your
simulation.
12. To see the list of pseudocomponents that you have created, edit the
properties for the stream you selected. The pseudocomponents will be listed
after pure components, with names that begin with NBP.
118 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
Customizing Thermodynamics
Occasionally, you may find that none of the thermodynamic models built into
CHEMCAD serve your needs for a particular simulation. If this should happen, you
can take one of two approaches to handling thermodynamics for the simulation:
either create your own K‐value or enthalpy model or create your own mixing rule.
Figure 9-06: Selecting the ADDK K-value option
After adding a custom enthalpy model, you can select it on the Enthalpy Models
tab of the Thermodynamic Settings dialog box, by using the Global Enthalpy Option
setting called ADDH.
CHEMCAD Version 7 User Guide 119
Customizing CHEMCAD
Figure 9-07: Selecting the ADDH enthalpy model
120 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
3. Copy the existing subroutine and paste the code below the example in the
code window. Rename the new subroutine copy.
4. Edit the new subroutine as needed to achieve the result that you want.
5. Return to CHEMCAD by either of two methods:
• Use [ALT‐TAB] or the Windows taskbar, leaving the VBA editor window
open.
• Click the View CHEMCAD button at the far left end of the VBA editor’s
toolbar to close the editor window.
Note: You can also use the [ALT–F11] key combination to toggle between CHEMCAD
and the VBA editor.
6. Save the current CHEMCAD simulation, then expand the relevant
CHEMCAD Explorer item again to see your newly defined item in the list.
CHEMCAD Version 7 User Guide 121
Customizing CHEMCAD
Figure 9-08: Selecting a VBA-defined reaction in the Kinetic Data dialog box
4. When you have defined the last reaction, click OK to return to the main
CHEMCAD window.
122 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
Figure 9-09: Selecting a VBA UnitOp
CHEMCAD Version 7 User Guide 123
Customizing CHEMCAD
The UnitOp Designer toolbar offers the following tools for creating your new
symbol:
• Basic drawing shapes: Line, Arrow Line, Polygon, Ellipse, Rectangle, and
RoundRect
• The TextBox tool, for adding text to your UnitOp symbol
• The Rotate, Flip, and Group tools, for manipulating drawn objects
• The Align and Space tools, for placing drawn objects more precisely
• Tools for ordering objects that overlap
Using these tools, create the symbol you want to represent your new UnitOp.
Note that in some cases, the drawing tools remain active until you either right‐click
on the workspace or select a different tool. If you create a shape unintentionally,
simply click the shape to highlight it, then press [DELETE].
To ensure that your new symbol is similar in size to other items on the UnitOp
palette, you can “borrow” an existing symbol to get a sense of its scale:
1. Click the simulation tab at the bottom of the workspace.
2. Drag a symbol of the desired size from the palette to the workspace.
3. Right‐click the symbol on the flowsheet and select Copy.
4. Click back to the UnitOp Designer tab.
5. Right‐click any blank area and select Paste.
You can now draw your new symbol to a scale that matches this symbol. Be sure
to delete the borrowed symbol, along with any drawing objects that you do not want
to include, before continuing.
124 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
Note: Placing ports precisely on a symbol outline can be challenging when done with
a mouse. Alternatively, you can use your keyboard’s arrow keys to fine‐tune the
position of selected ports.
Specifying Ports
Once the ports are all in the correct locations, you can specify them as desired. There
are two specifications available for UnitOp ports: Index and Link Direction.
The Index setting determines the order in which the ports will be calculated
within the UnitOp. By default, the first inlet port that you add is assigned index 1,
the second is assigned index 2, and so forth; outlet ports are also numbered in this
way.
The Link Direction setting is optional. When specified, it determines the
orientation of the stream segment entering or exiting a particular port. Link
orientations are given as cardinal directions. For example, you may want all the inlet
ports on the left side of a column to enter horizontally from the left, or the outlet port
on the bottom of a vessel to exit downward, regardless of where connecting UnitOps
are located.
To change the assigned order of a port or specify its link direction, right‐click the
port and select Port Identification.
The Select New Port Index dialog suggests a new Index value, which you can
keep or change. To specify the direction of stream entry or exit from the port, select
the desired direction from the Link Direction drop‐down list. When you have
finished specifying the port, click OK to close the dialog box.
CHEMCAD Version 7 User Guide 125
Customizing CHEMCAD
It is recommended that you specify (or at least verify) the index setting for each
inlet and outlet port before continuing.
126 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
The drawing file opens in the UnitOp Designer tab. You can now make any
needed changes to the drawing: add or delete items, resize an item, change text, and
so forth.
When you have finished making changes, select Edit > UnitOp Designer > Add
Ports, and proceed as before. To return to the same starting place again, simply open
the original drawing and repeat the process.
6. Add, move, or reconfigure ports as needed, then publish as usual.
7. If you want to keep this new version as a template for future changes, be sure
to save when CHEMCAD prompts you as you close the UnitOp Designer tab.
128 CHEMCAD Version 7 User Guide
Customizing CHEMCAD
• User‐added module: Created using Visual Studio or another C++ compiler
• VBA UnitOp: Created through the VBA Editor, which is part of CHEMCAD
The basic procedures for creating custom Excel UnitOps are covered in Chapter
10, Data Interfaces. Calculator UnitOps are defined by a programming language
called Parser, the syntax for which is documented in the CHEMCAD Calculator/Parser
Module guide, available on the Chemstations website.
C++ user‐added modules are developed using Microsoft’s Visual C++
development tool, the same tools that were used in the creation of CHEMCAD’s own
UnitOps. The procedures for creating C++ user‐added modules for use with
CHEMCAD are detailed in the User‐added Modules Guide, which is also available on
the Chemstations website.
VBA UnitOps are defined by VBA subroutines, and are described later in this
chapter.
The method you choose is an important first step toward creating a UnitOp, but
the choice is almost entirely up to you. Calculator UnitOps can be quick and easy to
set up, but they can’t do everything the other methods can. The Excel/Visual Basic
approach is very powerful and uses the familiar Visual Basic language for
development. A drawback to this method is that calculation can sometimes be slow
due to the use of Microsoft Excel to do the calculations. The most powerful and
fastest calculating method is the C++ user‐added module method, but if you are new
to C++, it may be challenging to use. VBA UnitOps are as powerful as those created
using C++, and are much easier to build.
Whichever method you use to program the calculations of your UnitOp, you will
likely need to create a dialog box to provide a user interface. A dialog box enables
users to send information into your UnitOp, for example the number of stages for a
distillation UnitOp. No matter what method you use to program your UnitOp, you
will use the Dialog Editor program to create the user interface.
CHEMCAD Version 7 User Guide 129
Customizing CHEMCAD
objects and properties. You should also have a firm understanding of simulation in
CHEMCAD before venturing into Dialog Editor.
The Dialog Editor program is separate from CHEMCAD. To launch it, select
Start > All Programs > Chemstations > Utilities > Dialog Editor.
Figure 9-10: The Dialog Editor window showing an open dialog
A detailed description of how to use the Dialog Editor is available on the
Chemstations website.
130 CHEMCAD Version 7 User Guide
Chapter 10
Data Interfaces
CHEMCAD enables you to exchange data with other programs through a variety of
methods. This saves time, effort, and the potential for keystroke error and data
omissions. In some cases, these data interfaces can enable CHEMCAD to link
directly into your plant information systems to run simulations without human
intervention.
The data interfaces that CHEMCAD uses are as follows:
• The Excel Data Map interface, which can link any value in a CHEMCAD
simulation to any cell in an Excel worksheet, or vice versa (note that running
CHEMCAD simulations from Excel requires a COM interface, described
below)
• The Visual Basic Application interface, which enables you to build custom
reactions, mixing rules, and UnitOps
• The OPC interface, which permits any OPC Client application to access
values in a CHEMCAD simulation
• COM interfaces, which allow any COM‐enabled program (such as MATLAB)
to access and control a CHEMCAD simulation
CHEMCAD Version 7 User Guide 131
Data Interfaces
Figure 10-01: The Excel Data Map Editor
132 CHEMCAD Version 7 User Guide
Data Interfaces
2. Click the Browse button and locate the target workbook. Select the workbook
file and click Open.
3. In the cell next to Excel Worksheet Name, type the name of the worksheet to
which you want to link your simulation.
Note: If you need to verify the name of the worksheet, you can click the Open button
to launch Excel and view the workbook.
4. Double‐click the cell below Map Rule to see a drop‐down list of mapping
options:
• To Worksheet Only enables you to send data from streams or UnitOps in
CHEMCAD to the selected worksheet.
• To CC Only enables you to send data from any cell on the worksheet to
the selected stream or UnitOp parameter in your simulation.
• For data reconciliation enables you to manipulate the data using
CHEMCAD’s Data Reconciliation feature.
Figure 10-02: Selecting a Map Rule option in the Excel Data Map Editor
5. Double‐click the cell below CC Obj Type to see a drop‐down list of mapping
options:
• Stream enables you to link an Excel cell or cell range to a stream on the
flowsheet.
• UnitOp enables you to link an Excel cell or cell range to a UnitOp on the
flowsheet.
• Misc enables you to change dynamic flowsheet settings.
6. Click the cell below CC Obj ID. Type the ID number of the stream or UnitOp
to which you want to link.
7. Double‐click the cell below Par ID to see a drop‐down list of parameters for
the selected UnitOp or stream. Scroll down and select an option from the list.
CHEMCAD Version 7 User Guide 133
Data Interfaces
Note: When you are importing cell data into CHEMCAD, the list of parameter
options is limited, as many values in a CHEMCAD simulation are calculated based
on other values.
8. If you chose a parameter that is related to a specific component (e.g., Comp
Mole fraction), you will need to specify the component. Double‐click the cell
below Component to see a drop‐down list of available components. Select a
component from the list.
9. Click the cell below WrkSht Cell/Range. Type the cell address or cell range
to which you want to link. Cell addresses should be formatted with the
column letter and row number, e.g., A1 or D17. Cell ranges should be
formatted as two such addresses (representing the range’s first and last
values) separated by a colon, e.g., A1:A12 or B5:E20.
10. If you are performing a data reconciliation, you can use the Weight column
to give certain items in the reconciliation more importance than others.
11. Repeat the procedure until you have specified all of the cells or cell ranges
that will link to your simulation.
12. Save the Data Map by selecting File > Save As. Type a name for your Data
Map and then click OK. The newly created Data Map now appears on the
CHEMCAD Explorer under the Data Maps item.
Figure 10-03: List of available Data Maps in CHEMCAD Explorer
13. To leave the Data Map open and return to your simulation, use the tabs at the
bottom of the main CHEMCAD workspace. To close the Data Map, select
File > Close, or click the red X button on the Data Map’s tab.
134 CHEMCAD Version 7 User Guide
Data Interfaces
Figure 10-04: The dialog box for configuring execution rules
2. Click the square button next to the first field in the Select Data Maps column
to bring up the Select Data Map dialog box.
Figure 10-05: Selecting a Data Map from the list
3. Select the name of the Data Map for which you want to set rules, and click
OK to return to the Data Map Execution Rules dialog box. Repeat this step
for all other Data Maps whose rules you want to set up at this time.
CHEMCAD Version 7 User Guide 135
Data Interfaces
4. In the Before Simulation Runs field next to each selected Data Map, click the
drop‐down list to choose an action for that Data Map to perform before
calculations begin:
• Do Nothing performs no action before the simulation is run. You might
use this option to disable a Data Map temporarily.
• To Workbook sends the requested data to Excel before running the
simulation. You might use this option when you want to pull data from
inlet streams or UnitOp specifications.
• To CHEMCAD sends the requested data in Excel to CHEMCAD before
running the simulation. You might use this option when you want to feed
data to inlet streams or UnitOps with data from the Excel worksheet.
5. In the After Simulation Runs field next to each selected Data Map, click the
drop‐down list to choose an action for that Data Map to perform after
calculations are complete:
• Do Nothing performs no action after your simulation has run. You might
use this option to disable a Data Map temporarily.
• To Workbook sends the requested data to Excel after running the
simulation. You might use this option when you want to send data from
streams or calculated parameters of UnitOps to the workbook in Excel.
Figure 10-06: Three different Data Maps with rules set up
6. When you have configured all of the Data Maps that you want to use, click
OK to save your rules and close the Data Map Execution Rules dialog box.
You can now run the simulation. If you open the Excel files that are linked to the
simulation, you will be able to see the parameters of streams and UnitOps related to
the Excel Data Map. You can also perform your own calculations in the workbook
based on the data linked to CHEMCAD.
136 CHEMCAD Version 7 User Guide
Data Interfaces
Specification Sheets
Using the interface with Microsoft Excel, CHEMCAD allows you to output
simulation data to an Excel spreadsheet resembling a vendor specification sheet, as
discussed in Chapter 8, Output and Reports. Customizing these spec sheets saves you
time by outputting data in the format required by your company or vendor.
To customize the spec sheet for a specific UnitOp type, edit the corresponding
Excel spreadsheet in the following directory:
C:\Program Files\Chemstations\CHEMCAD 7\templates
If the UnitOp type you want is not represented by the Excel files in this directory,
you can copy the generic specsheet.xls file and use it as a template for a new UnitOp
spreadsheet.
CHEMCAD Version 7 User Guide 137
Data Interfaces
Place the copy in the same directory, and make its file name the standard four‐
character abbreviation for the UnitOp type in question. For example, to create a spec
sheet template for the Flash UnitOp, you would need to name the file copy flas.xls.
See the CHEMCAD Help information about your specific UnitOp if you need to look
up this abbreviation.
Before you continue, you will need to turn off the Read‐only attribute for the
new spreadsheet file. The quickest way to do this is to right‐click the file within the
Windows Explorer, select Properties, and then clear the Read‐only check box in the
Properties dialog box.
Once the copy is renamed and the Read‐only attribute is turned off, you can
open the spreadsheet and edit it as needed.
OPC Applications
OPC can be applied as follows:
• Inferential sensors: Sometimes called soft sensors, inferential sensors use one
or more measured variables to estimate another variable. Using CHEMCAD
simulations and data from your plant’s DCS, you can embed simulations to
provide data such as concentrations, heat duty, and fouling factor, which
would not normally be available.
• Operator training: You can couple an operator HMI to a dynamic simulation
to create a training simulator that can help train operators in a safe and
effective way.
138 CHEMCAD Version 7 User Guide
Data Interfaces
OPC Compliance
Chemstations is a Member of the OPC Foundation, an organization devoted to
maintaining the OPC standards. CHEMCAD has been certified for, and interop
tested for, OPC DA standard 2.05a.
CHEMCAD Version 7 User Guide 139
Data Interfaces
Note: Most of the data items in a simulation have engineering units associated with
them. In these cases, we usually define two separate tags, one containing the data
value and the other containing the units string. All units strings are read only from
OPC. The units strings are governed by the settings inside the simulation.
The groups in CHEMCAD’s OPC namespace are organized as follows:
140 CHEMCAD Version 7 User Guide
Data Interfaces
• CHEMCAD.SimulationServer: This is the OPC server name. By convention,
this name is followed by a version number, e.g.,
CHEMCAD.SimulationServer.1, to indicate the OPC Server version. This is
the server name to which OPC clients will connect.
• CHEMCAD Group: This group contains any information that is not
dependent on a stream or UnitOp, and all commands used to run
CHEMCAD.
• Streams Group: This group contains a series of subgroups, one for each
stream on the flowsheet numbered by stream ID number.
• UnitOperations Group: This group contains a series of subgroups, one for
each unit operation on the flowsheet, numbered by UnitOp ID number.
COM Interfaces
Component Object Model (COM) is a Microsoft‐standard platform that enables
programs to share content such as data and calculation routines. This interface
makes it possible for other programs to control a CHEMCAD simulation.
CHEMCAD acts as a COM server, so any program that can act as a COM client
can be made to interface with CHEMCAD in this way. If you aren’t certain whether
your application can act as a COM client, check with the software vendor.
Note: Using the COM interface to CHEMCAD is a complicated procedure that
requires some experience in programming. If your organization lacks in‐house
expertise in programming, consider bringing in a third‐party resource to assist you
with the procedure.
The following section is a brief walk‐through of a simple COM interface between
Excel and CHEMCAD.
CHEMCAD Version 7 User Guide 141
Data Interfaces
• Read the revised values back into Excel
Normally, using COM interfaces involves some programming. We have created
an example called VBCLient.xls to help you overcome that hurdle; you don’t need to
write any code at all to use this tool. Even if you need to write your own program,
the code in the macros of VBClient will come in handy as a guide.
Note: Some values are read‐only. For example, VBClient does not allow you to
change a stream’s total flow rate directly; you must instead change the component
flow rates to make a change to the total flow rate.
3. Click Save Data to push your changes to the CHEMCAD simulation.
4. Click Run All to run the simulation.
5. Note the changes to the data on the Streams and UnitOps sheets.
142 CHEMCAD Version 7 User Guide
Data Interfaces
strJobName = ""
selUpdateStrUopData = True
selOK = False
End If
Call UpdateVersion
End Sub
The most important line in that whole subroutine is:
Set objCHEMCAD = CreateObject("CHEMCAD.VBServer")
In that single line, Excel loads CHEMCAD into memory.
Loading a simulation is accomplished with this simple line from the subroutine
called LoadJob:
retval = objCHEMCAD.LoadSim(strJobName, 0)
Running a simulation can be as simple as this line from the RunJob subroutine:
retflag = objCHEMCAD.RunJob
The COM Interface Reference section of the CHEMCAD Help file (listed under
the heading Customization) provides a full reference of the commands available
through COM.
CHEMCAD Version 7 User Guide 143
Data Interfaces
144 CHEMCAD Version 7 User Guide
Process Simulation Essentials
Example Book
All material © 2021 Chemstations, Inc.
Table of Contents
1 – Thermodynamics
Thermodynamics Selection: Chemicals.................................................................................... 3
Thermodynamics Selection: Hydrocarbons .............................................................................. 5
Global and Local Thermodynamics .......................................................................................... 7
Binary Interaction Parameter (BIP) Regression ........................................................................ 8
2 – Phase Equilibria
Flash Calculations .................................................................................................................. 10
Vapor-liquid Equilibrium: Non-ideal Systems .......................................................................... 12
Vapor-liquid Equilibrium: Azeotropes ..................................................................................... 14
Vapor-liquid-liquid and Liquid-liquid Equilibrium ..................................................................... 17
3 – Separators
Distillation Basics: Benzene/Toluene ..................................................................................... 18
Distillation Models in CHEMCAD............................................................................................ 20
Column Design: Benzene/Toluene/Xylene ............................................................................. 22
Column Performance: Benzene/Toluene................................................................................ 24
Absorption and Stripping ........................................................................................................ 26
Liquid-liquid Extraction ........................................................................................................... 28
Ethyl Acetate by Reactive Distillation ..................................................................................... 29
1
4 – Reactors
Reactor Models in CHEMCAD ............................................................................................... 30
EREA Shift and Methanation Reactors................................................................................... 31
Equilibrium Reactor (EREA) ................................................................................................... 33
Kinetic Reactor (KREA) .......................................................................................................... 34
5 – Heat Exchangers
Heat Exchangers: Principles and Applications ....................................................................... 36
Heat Exchangers: Use Cases ................................................................................................ 38
Heat Exchangers: Equipment Design, Sizing, and Costing .................................................... 40
Heat Exchangers: CC-THERM Modes ................................................................................... 42
6 – Recycle
Recycle: Closing the Loop...................................................................................................... 44
Nested Recycle: Closing the Inner Loop ................................................................................ 45
Nested Recycle: Closing the Outer Loop................................................................................ 46
7 – Pressure
Flow Models: Input Specifications .......................................................................................... 47
Single-branch Piping Configurations ...................................................................................... 49
8 – Reports and Charts
Reports: Benzene/Toluene/Xylene Distillation ........................................................................ 51
Charts: Phase Equilibria ......................................................................................................... 53
Charts: Benzene/Toluene Distillation ..................................................................................... 55
Charts: Exchangers and Plug Flow Reactor ........................................................................... 57
9 – Tools
Tools: UnitOps ....................................................................................................................... 59
Tools: META UnitOp .............................................................................................................. 60
Tools: Child Simulation for META UnitOp ............................................................................... 61
Tools: Sensitivity Analysis ...................................................................................................... 63
Controller: Simple Applications .............................................................................................. 65
Controller: Refrigeration Cycle ............................................................................................... 66
Controller: Separators ............................................................................................................ 68
2
Thermodynamics Selection: Chemicals
The selection of K-value and enthalpy models is the most critical step in process
simulation. An improper selection leads to unreliable results.
Once you have selected all the components involved in the process, the Thermodynamic
Suggestions dialog box will appear. You can either click Cancel to enter thermodynamics
manually, or enter the desired parameters. In this example, an equimolar mixture of
acetonitrile and benzene is flashed with specified P = 101325 and mole vapor fraction =
0.05.
With this example, you can learn about the typical K-value models used for non-ideal
solutions. These K-value models are based upon the excess Gibbs free energy and use
activity coefficient methods (e.g., Wilson, NRTL, UNIQUAC, and UNIFAC), as well as
binary interaction parameters (BIPs).
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Types of Solutions" and "Thermodynamics."
Note: Use the suggestions of the algorithm as a guide only. Proper selection of
thermodynamics is the engineer's responsibility. Your simulation may call for the use of a
different model.
3
For instance, the acetonitrile/nitromethane system is fairly ideal, and using the Ideal
Vapor Pressure (Raoult's Law) or an activity coefficient model (NRTL, UNIQUAC) won't
make much difference. This is not the case for acetonitrile/benzene or benzene/water,
where the departure from ideal behavior is strong. For instance, the acetonitrile/benzene
forms an azeotrope, and the benzene/water system exhibits liquid-liquid and vapor-
liquid-liquid equilibrium.
Note: In the K-value Models tab, change the Global Phase Option to
Vapor/Liquid/Liquid/Solid so that if liquid-liquid equilibrium exists, Stream 3 will
contain the light liquid phase.
To use this example, select a pair of components and specify composition in the feed.
Open the Thermodynamic Settings dialog and change the Global K-value Model
setting. Run the simulation and evaluate the results for the liquid streams. Notice any
differences among Ideal Vapor Pressure (VAP), NRTL, UNIQUAC, and UNIFAC. Notice if
more than one liquid phase exists.
To generate the TXY diagram and XY diagram for any pair of components in this
simulation, click the Charts drop-down in the Results group of the Home tab, then
select TPXY under the Thermodynamic category.
4
Thermodynamics Selection: Hydrocarbons
The selection of K-value and enthalpy models is the most critical step in process
simulation. An improper selection leads to unreliable results.
Once you have selected all the components involved in the process, the Thermodynamic
Suggestions dialog box appears. You can either click Cancel to enter thermodynamics
manually, or enter the desired parameters. In this example, a mixture of hydrocarbons
and water is flashed at T = 300 K and P = 690 kPa.
Considering the components and the temperature and pressure range, the algorithm
suggests Soave-Redlich-Kwong (SRK) as both the K-value and enthalpy models. The
next step is the Thermodynamic Settings dialog box, where you can make further
changes or override the selection made by the algorithm. Notice that the
Water/Hydrocarbon Solubility option is marked as Immiscible. As a result, Stream 4 has
pure water.
Note: If water is not part of the process but is used as a utility, it is recommended that
you select water as a component to ignore in the Thermodynamic Suggestions dialog
box, to prevent a misleading selection.
5
Importance of the specified temperature and pressure range: Suppose the
process occurs at very low temperature ( < -70 °C) and high pressure ( > 10000000
Pa). Open the Thermodynamic Suggestions dialog and enter a temperature range of 180
to 250 K and a pressure range of 101325 to 1e+06 Pa.
Notice how the temperature and pressure range affects the selection. The algorithm now
suggests Peng-Robinson (PR) instead. PR is a common selection when the process
conditions are extreme.
Note: Use the suggestions of the algorithm as a guide only. Proper selection of
thermodynamics is the engineer's responsibility. Your simulation may call for the use of a
different model.
6
Global and Local Thermodynamics
A mixture of ethanol and water at 170 °F and atmospheric pressure is used for this
example. Both Flash UnitOps have the same specifications.
To review or change the Global K-value: on the Home tab, in the Setup group, click
Thermodynamic Settings, then click the Global K-value Model drop-down list.
To set local thermodynamics: on the Home tab, in the Setup group, click
Thermodynamic Settings, then check the Set local thermodynamics option. Click
OK, then enter 2 for the UnitOp ID and click OK again. A new dialog box will appear,
where you can select a different K-value (and/or enthalpy model) for the selected
UnitOp.
To review the thermodynamics for the flowsheet, click the Reports drop-down (Home
tab, Results group). Under the Flowsheet heading, choose Thermodynamics. Notice
that the vapor fraction and enthalpy of the feed are governed by the Global K-value.
Then, the Flash UnitOp flashes the feed using the local K-value, thus giving a slightly
different result.
This feature is often used when the phase equilibrium calculations for a unit within the
process require a particular Equation of State or Activity Coefficient model.
7
Binary Interaction Parameter (BIP) Regression
This example details how to review available BIPs in CHEMCAD's database, enter BIPs
manually, and regress BIPs from VLE data. This is an advanced topic.
To learn more about BIPs, press [F1] to open the CHEMCAD help file, then see the help
topic called "Overview of BIPs in CHEMCAD."
First, three BIP sets were created (Home tab, Setup group, Thermodynamic
Settings, K-value Models tab, enter 3 under No. of BIP sets).
Set 1 uses built-in BIPs from CHEMCAD's database. Click the Component Database
tab, then in the System Database group, click the BIP Data drop-down and choose
Database BIPs. Choose any pair of components to review available BIPs.
Set 2 has BIP parameters entered manually. Click the Thermophysical tab, then in the
Binary Interactions group, click Edit BIPs. Here, the recommended values found in
DECHEMA's Chemistry Data Series - Vapor-Liquid Equilibrium Data Collection for the
Acetone/Water binary system were entered in the Bij, Bji, and Alpha ij columns, thus
overriding CHEMCAD's built-in parameters.
Note: the values as shown on the reference have been divided by Gas constant R in
CHEMCAD R = 1.98721 cal/mol/deg.K to make them comparable to CHEMCAD's.
Set 3 was created after regressing VLE data for acetone (1)/water (2) at a constant
pressure of 1.013 bar from the same source. To perform a BIP regression, click the
Thermophysical tab, then in the Binary Interactions group, click BIP Regression.
8
Select the components, then Regress TPxy/Pxy/Txy VLE data and enter data in the
appropriate columns. (For more, see the "BIP Regression" help topic.)
Note: The first component you select will be treated as the i component by the program.
Make sure that your selection matches the proper i component in the VLE data.
Review the flowsheet specifications and BIPs by clicking the Reports drop-down (Home
tab, Results group) and choosing Thermodynamics under the Flowsheet heading.
Note: i and j refer to the order in the component list (i.e., acetone = 1; water = 2).
To compare the results, activate the BIP set first (Home tab, Setup group,
Thermodynamic Settings, K-value models tab). In the Default BIP set field, type
the number of the BIP set of interest, then run the simulation. Do results differ when
using the various BIP sets?
Reference:
Gmehling et al. "Vapor-Liquid Equilibrium Data Collection," Chemistry Data Series, vol. I,
part 1b, DECHEMA, Frankfurt/Main, 1988. pp. 146 and 153.
9
Flash Calculations
In Vapor-Liquid Equilibrium (VLE), liquid and vapor phases coexist in equilibrium. When
the overall composition is known (feed composition), then two variables are required to
fix the state of the system.
Based on the feed composition and conditions, the Flash UnitOp calculates the other
variables, as well as the quantities and compositions of the vapor and liquid phases in
equilibrium.
Modes 6 and 7: Specify P or T and perform isentropic flash, respectively (not shown in
this example).
Modes 8 and 9: Specify P or T and water dew point T or P, respectively (not shown in
this example).
This example shows the typical Flash calculations using an equimolar mixture of benzene
(1)/ethylbenzene (2), which is wide-boiling and thus easily separated.
10
Additional exercises:
d) Benzene (1)/cyclohexane (2) mixture at various compositions. Can you find the
azeotropic composition?
To generate binary TPXY charts, click the Charts drop-down (Home tab, Results group)
and select TPXY. Specify the two components (1 for the most volatile) and either
constant pressure (PXY) or constant temperature (TXY).
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 341-347, 367-369.
11
Vapor-liquid Equilibrium: Non-ideal Systems
In this example, the Flash UnitOp is used to model a single vapor-liquid equilibrium
stage.
All Flash UnitOps have Mode 2 specified (Specify T and P; calculate V/F and Heat). You
can specify other modes to perform various calculations. See the example called
_Process Simulation Essentials\2 Phase Equilibria\1 - Flash calculations.
With this example, you can learn about the typical K-value models used for non-ideal
solutions. These K-value models are based upon the excess Gibbs free energy and use
activity coefficient methods (e.g., Wilson, NRTL, UNIQUAC, and UNIFAC), as well as
binary interaction parameters (BIPs).
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Types of Solutions" and "Thermodynamics."
CHEMCAD has built-in BIPs from numerous chemical components in the database. Click
the Component Database tab, then in the System Database group, click the BIP
Data drop-down and choose Database BIPs. Choose any pair of components to review
available BIPs.
12
Notice how the K-value selection determines the molar rate and composition for the
vapor and liquid products once the flash calculation is performed.
Click Stream Box (Drawing tab, Insert group) and then click Product Streams to
generate a table to compare the K-value models side by side.
You can test for two different systems as specified below. This example has case a) set
up and NRTL as the global K-value.
a) Positive deviation from Raoult's Law: Methyl Ethyl Ketone (1)/Toluene (2) at T = 50
°C and P = 20 kPa
Local K-values have been used for the Flash UnitOps. The first Flash UnitOp (1) has
Global K-value, which can be modified by clicking Thermodynamic Settings (Home
tab, Setup group) and then clicking the Global K-value Model drop-down.
Note: Charts are generated using the Global K-value. Match the Global K-value to any of
the K-value models in the flowsheet. Then run the top Flash UnitOp (1). Select Stream 1
and then generate a TPXY chart (Home tab, Results group, Charts drop-down,
Thermodynamic heading, click TPXY).
Note: The use of local thermodynamics is for illustrative purposes as it is not typical to
have that many local K-value models in a single flowsheet.
Review the flowsheet specifications and BIPs for each activity coefficient by generating a
Thermodynamics report (Home tab, Results group, Reports drop-down, Flowsheet
heading, click Thermodynamics). Note that I and J refer to the order in the component
list.
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 348-350, 352-356, 435-439.
13
Vapor-liquid Equilibrium: Azeotropes
In this example, the Flash UnitOp is used to model a single vapor-liquid equilibrium
stage.
All Flash UnitOps have Mode 1 specified (Specify V/F and P; calculate T and Heat). You
can specify other modes to perform various calculations. See the example called
_Process Simulation Essentials\2 Phase Equilibria\1 - Flash calculations.
With this example, you can learn about the typical K-value models used for non-ideal
solutions. These K-value models are based upon the excess Gibbs free energy and use
activity coefficient methods (e.g., NRTL, UNIQUAC, and UNIFAC), as well as binary
interaction parameters (BIPs).
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Types of Solutions" and "Thermodynamics."
Activity coefficient methods are used in processes where the solution is non-ideal or
highly non-ideal, two liquid phases may exist, and azeotrope(s) may exist.
CHEMCAD has built-in BIPs from numerous chemical components in the database. Click
the Component Database tab, then in the System Database group, click the BIP
Data drop-down and choose Database BIPs. Choose any pair of components to review
available BIPs.
14
The purpose of this example is to determine whether the mixture forms an azeotrope,
and if so, at what temperature and composition this occurs.
Azeotropic mixtures are liquid mixtures that exhibit sufficiently large deviations from
Raoult's Law behavior. As a result, the T-x and T-y curves exhibit a minimum (positive
deviations) or a maximum (negative deviations) at constant pressure. At the azeotropic
point x1 = y1 and the dew point and bubble point curves intersect. A boiling liquid of this
composition (azeotropic point) produces a vapor of the same composition. No separation
is possible by distillation since the solution is constant boiling.
Notice how the K-value selection determines the azeotropic temperature and
composition. Notice that the Ideal Vapor Pressure and SRK models fail to detect
azeotropes.
2) Test whether or not a K-value method can predict the existence of such an azeotrope.
3) Estimate the azeotropic temperature and azeotropic point by looking at the TXY
diagram (Home tab, Results group, Charts drop-down, Thermodynamic heading,
click TPXY) and specifying pressure at 1 bar.
4) Estimate the azeotropic pressure and azeotropic point by looking at the PXY diagram
(again, click TPXY from the Charts drop-down) and specifying the temperature in
Celsius.
5) Perform flash calculations to determine dew point and bubble point of mixtures. At the
azeotropic composition, bubble T = dew T (for constant P).
Is the azeotropic temperature and composition the same for all K-values?
Is the azeotropic temperature and composition the same when you change the pressure?
Which of the K-values does not predict the existence of the azeotrope (when there is
one)?
Ethanol (1)/water (2); ethanol (1)/benzene (2); ethanol (1)/cyclohexane (2); ethanol
(1)/toluene (2); benzene (1)/cyclohexane (2); benzene (1)/toluene (2).
15
This example shows the ethanol (1)/water (2) system at constant P = 1 bar. The
composition of the feed is close to the azeotropic point.
Local K-values have been used for the Flash UnitOps. The first Flash UnitOp (1) has a
global K-value, which can be modified by clicking Thermodynamic Settings (Home
tab, Setup group) and then clicking the Global K-value Model drop-down.
Note: TPXY charts (Home tab, Results group, Charts drop-down, Thermodynamic
heading, click TPXY) can be generated using any K-value. Under Specify
thermodynamics, use the K-value drop-down to select a K-value model. Click Add Row
to compare the results from different K-value models on the same chart. By default,
rows are initialized using the Global K-value.
Note: The use of local thermodynamics here is for illustrative purposes, as it is not
typical to have that many local K-value models in a single flowsheet.
Review the flowsheet specifications and BIPs for each activity coefficient using the
Thermodynamics report (Home tab, Results group, Reports drop-down, Flowsheet
heading, Thermodynamics).
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 347-355, 446-449, 474-475.
16
Vapor-liquid-liquid and Liquid-liquid Equilibrium
In this example, water is mixed with an organic feed and flashed at the inlet temperature
and pressure conditions.
NRTL was selected as the K-value for this example because it can predict liquid-liquid
equilibrium.
Note: The Global Phase Option has been changed to Vapor/Liquid/Liquid/Solid to allow
this calculation. This is set by clicking Thermophysical Settings (Home tab, Setup
group) and then selecting a Global Phase Option on the K-value Models tab.
To plot a TXY or PXY diagram, select stream 3 and generate a TPXY chart (Home tab,
Results group, Charts drop-down, TPXY). Select the pair of components, fix the
pressure (or temperature), and click OK to generate a TXY diagram and XY diagram.
What if you change the temperature of the organic feed to 170 °F? Is there a vapor
phase?
What if you add ethanol to the water feed? Does ethanol split into the liquid phases?
What is the phase distribution and composition if UNIQUAC or UNIFAC is used? To find
out, click Thermodynamic Settings (Home tab, Setup group) and then select
UNIQUAC as the Global K-value Model on the K-value Models tab.
17
Distillation Basics: Benzene/Toluene
For an equilibrium stage at a given pressure, the range of possible product compositions
is bounded by the bubble point and dew point compositions at that pressure.
This concept is better understood by looking at the TXY diagram. On the Home tab, in
the Results group, click the Charts drop-down. Under the Thermodynamic heading,
choose TPXY and select the components in order of relative volatility (benzene = 1,
toluene = 2) at constant pressure of 1.72 bar. CHEMCAD generates TXY and XY charts.
Starting at 0.4 mole fraction of benzene (the feed composition), intersect the bubble
point (bottom curve) and dew point (top curve) at T = 118 °C. These are the mole
fractions of benzene in the liquid and vapor products, respectively. These in turn become
the feed compositions for streams 5 and 6. For stream 5, find the intersection with T =
115 °C to find the compositions of streams 7 and 8. Notice how the mole fraction of
benzene in the vapor increases continuously. The same can be done for stream 6 by
finding the intersection of the curves with T = 120.5 °C
18
Notice how the mole fraction of benzene in the liquid product decreases continuously. As
more equilibrium stages are added, benzene concentrates in the vapor, while toluene
concentrates in the liquid.
For this example, a Tower distillation column with 10 stages was used to separate the
mixture. The reflux ratio was set at 1 and the bottoms mole rate at 50 kmol/h.
19
Distillation Models in CHEMCAD
CHEMCAD offers both shortcut and rigorous methods for solving multicomponent
distillation problems. The shortcut method uses non-rigorous thermodynamics, and is
based on the assumption of constant molal overflow, which does not happen in reality.
Both rigorous methods use thermodynamics to calculate mass and energy balances,
which model real behavior.
The Shortcut model (SHOR) uses the Fenske-Underwood-Gilliland method. Both rating
and design cases are provided.
For this example, design mode was used to calculate the minimum number of stages
required when reflux ratio and the split fractions of light key and heavy key components
are specified.
Note: This method may not be suitable for column design and may give incorrect results
in systems with azeotropes. It should be used to obtain only an estimate for the
minimum number of stages before designing a Tower or SCDS column.
The Tower model (TOWR) uses the inside-out rigorous method for multistage VLE.
The Tower Plus model (TPLS) uses the inside-out rigorous method too, but allows for
complex columns. This model is used for petroleum and refining applications. To learn
more, see "Atmospheric distillation of crude oil" under the Distillation and Absorption
folder.
20
The SCDS model (SCDS) uses the simultaneous corrections method for multistage VLE.
For this example, all three rigorous models were specified in the same way. They use
different mathematical algorithms and number of iterations to converge to a solution,
but the solution will be the same. When computers were less powerful, the choice
between TOWR and SCDS was related to the process in question. TOWR usually requires
fewer iterations and converges faster, but this is not as relevant using modern
computers. However, the SCDS allows for special distillation cases that TOWR does not
support.
All three rigorous models will solve standard absorbers, strippers, and fractionators, with
and without reboilers, condensers, multiple feeds, and multiple draws. The choice among
models is more easily made by exception:
SCDS: 1) Tray efficiency less than 100% (Murphree efficiency); 2) Mass transfer model
(packed or tray column); 3) Reactive distillation; 4) Highly non-ideal thermodynamics;
5) Electrolytes.
To learn more, press [F1] to open the CHEMCAD help file, then search for the help topic
that addresses the particular distillation model.
21
Column Design: Benzene/Toluene/Xylene
The first step is to design a column that separates mostly benzene in the overhead. This
requires guessing or estimating the column stages, feed tray location, and mode
specification.
For this example, a Tower distillation column with 10 stages, total condenser, and
reboiler was used to separate the mixture. The feed enters at tray 10. A reflux ratio of 5
was set as the condenser mode specification, and a mole fraction of 0.0001 of benzene
in the bottom was set as the reboiler mode specification.
With these specifications, the overhead purity does not reach the 99.9 mole % target. By
specifying component mole fraction of benzene (=0.999) instead of reflux ratio, we allow
the reflux ratio to vary until the mass balance is achieved. The calculated reflux ratio
turns out to be 19.16.
This reflux ratio is quite large. It can be decreased by increasing the number of stages
(e.g., 30 stages) and/or relocating the feed tray. Specifying N = 30 and feed tray = 15
gives a reflux ratio of 2.3.
22
Once the benzene has been separated, a second column is needed to separate toluene
from o-xylene. The procedure is the same as for the first column. The condenser mode
specification is set at 0.999 mole fraction of toluene in the distillate, while the reboiler
mode specification is set at 0.999 mole fraction of o-xylene. Using 20 stages and feeding
the bottoms of the first column to the second column at tray 10 results in the desired
separation, with a reflux ratio of 5.4 for UnitOp 4. Specifying N = 30 and feed tray = 15
lowers the reflux ratio to 1.8, and gives 99.9 mole % products.
To obtain a summary of results for the column(s), click the Reports drop-down (Home
tab, Results group) and then under the UnitOp heading, click Select. For tabulated
results, right-click the UnitOp and select View Column Profile. Select Plot Column
Profile from the right-click menu to generate charts for the temperature profile, total
vapor flow, and/or total liquid flow.
Note: In the Tower specification dialog, under the Convergence tab, notice that the
mode 6 (Auto Estimation) is used. This means that CHEMCAD will try its best to make
the column converge. In the case that the mode specifications are unfeasible, the UnitOp
ID will turn yellow and CHEMCAD will issue a warning: "Can't converge with original
specs. Alternative optimal solution is found."
23
Column Performance: Benzene/Toluene
50 % vaporized feed
24
Then, the effect of changing a parameter or specification is investigated. This activity can
be carried out automatically using the Sensitivity Analysis feature. To learn more, press
[F1] to open the CHEMCAD help file, then see the help topic called "Sensitivity Analysis."
You can also see the example called _Process Simulation Essentials\9 Tools\3 -
Sensitivity analysis - distillation.
As a sample, a sensitivity analysis named "FeedLoc" has been conducted. It records the
mole fraction of benzene in the distillate as the feed location is changed from N = 2 to N
= 9 in equal steps.
The sensitivity analysis tools are found on the Analysis tab, in the Sensitivity group.
Using the Select Sensitivity Analysis drop-down, select FeedLoc, then click Run All.
To review the input for the analysis, return to the Sensitivity group (FeedLoc should still
be selected) and click Edit Sensitivity Analysis.
To review the results, return to the Sensitivity group and click Report Results. The
Sensitivity Analysis Report indicates the optimum feed location to be tray 5.
Note: The sensitivity analysis enables you to test multiple cases efficiently, but it does
not provide you the optimum answer.
The "alternative case" achieves the specified separation while maximizing recovery and
minimizing reflux ratio.
With this example, you can experiment with the specifications and compare the results
to the base case. By doing this, you can identify trends and design an optimization
strategy.
Finding the optimum usually involves the interplay of many parameters and
specifications, as well as economic considerations. Column design is often a trial-and-
error process.
The alternative design achieves 95% purity and 90% recovery of benzene in the
distillate. The feed conditions and pressure drop were not changed with respect to the
base case. The number of stages and feed location were adjusted to maintain the reflux
ratio below 3.
To obtain a summary of results for the column(s), click the Reports drop-down (Home
tab, Results group) and then under the UnitOp heading, click Select. For tabulated
results, right-click the UnitOp and select View Column Profile. Select Plot Column
Profile from the right-click menu to generate charts for the temperature profile, total
vapor flow, and/or total liquid flow.
25
Absorption and Stripping
This example shows the configuration and performance of an absorption column (UnitOp
1) and a stripping column (UnitOp 2). Propane is the key component in both cases--that
is, the component which is transferred from one phase to the other, with nitrogen mostly
in the vapor phase and decane in the liquid phase.
Absorption column:
The absorbent (i.e., liquid) is fed at the top of the column and the mixture containing the
key component is fed at the bottom. The streams flow countercurrently and propane is
absorbed into the liquid phase.
The stripping agent (i.e., gas) is fed at the bottom of the column and the mixture
containing the key component is fed at the top. The streams flow countercurrently and
propane is transferred to the vapor phase.
26
Key variables:
The component separation depends on the number of stages and the ratio of liquid-to-
vapor feed rates. The identity of the absorbent or stripper also affects the performance.
Note: Streams 2 and 6 should always enter the bottom of the column, so change the
feed stage to be the same as the number of stages.
What if you increase or decrease the flow rate of decane (1) or nitrogen (2)?
What if you use dodecane (i.e., a heavier liquid) as the absorbent instead?
Next, this example shows an absorption column followed by a desorption column (a.k.a.
regenerator). First, propane is recovered by absorption using decane. Then, decane is
regenerated (i.e., recovered and recycled back to the absorption column) in the
desorption column. This arrangement is typical of processes involving the absorption of
impurities feeding the heavy solvent at stage 1 and the regeneration of such solvent in a
desorption/regeneration step. Typical processes include gas sweetening and gas
dehydration.
For relevant examples, see the see the examples in the Gas Processing folder.
To review the column results, first right-click the UnitOp to bring up the UnitOp menu.
Click Plot Column Profile or View Column Profile to see the data in chart or tabular
format.
27
Liquid-liquid Extraction
The solvent (water) and the feed are two essentially immiscible liquids. The solute
(acetone), to be extracted from benzene by water, is soluble in both phases.
On the Home tab, in the Results group, click the Charts drop-down. Under the
Thermodynamic heading, choose Binary LLE, then select any combination of two
components (acetone-benzene, acetone-water, or water-benzene).
Two key design variables are 1) number of trays and 2) water flow rate. This example
shows the optimized design, but you can still modify the number of trays, feed location,
and water flow rate to see the effects in the separation.
NRTL was selected as the K-value because it serves to model the non-ideal behavior in
the liquid phase.
28
Ethyl Acetate by Reactive Distillation
In reactive distillation, phase equilibrium and chemical reaction occur in the same
equipment. Phase separation is controlled by phase equilibrium relations or rate-based
mass and heat transfer mechanisms (i.e., packed columns); chemical reactions are
controlled by chemical equilibrium relations or by reaction kinetics. The reaction takes
place in the liquid phase.
Kinetic data for the forward and backward reaction were entered into the column.
Double-click on the column (1) to open the SCDS Distillation Column dialog box. Notice
that Check here for reactive distillation is checked. Click OK to open the Reactive
Distillation Data menu, then click on the options to review the input data.
NRTL binary interaction parameters (BIPs) are used to account for this
thermodynamically complex system with two liquid phases and vapor phase association.
To review BIPs, click the Reports drop-down (Home tab, Results group), then under
the Flowsheet heading, choose Thermodynamics.
To review the K-value and vapor phase association selections, click Thermodynamic
Settings (Home tab, Setup group).
29
Reactor Models in CHEMCAD
This example shows an esterification reaction between acetic acid and ethanol to
produce ethyl acetate and water using all of CHEMCAD's reactor models, with the
exception of the vessel reactor, which involves dynamics. The reaction takes place in the
liquid phase and the NRTL K-value has been chosen to model the non-ideal behavior of
the mixture.
For both the equilibrium reactor and the Gibbs reactor, the reaction stoichiometry for the
forward reaction has been entered.
Note: The Gibbs reactor is not well suited to liquid-phase reactions. It is shown in this
example to illustrate its setup.
For both the continuous stirred-tank reactor (CSTR) and the plug flow reactor (PFR), the
reaction stoichiometry and kinetic data (frequency factor and activation energy) have
been entered for both the forward and reverse reactions.
For the stoichiometric reactor, the reaction stoichiometry and fractional conversion of
ethanol have been specified.
All reactor UnitOps operate isothermally at 50 °C. You may choose Adiabatic as the
thermal mode when specifying the reactor.
Exercises:
To learn more about each model, open the relevant specification dialog box, then press
[F1] to open the appropriate topic in the CHEMCAD help file.
30
EREA Shift and Methanation Reactors:
Comparison Between A+B/T and Special Methods in CHEMCAD
This simulation compares the resulting equilibrium conversion when changes are made
to the feed composition and conditions.
Two of the most common reactions will be evaluated using the Equilibrium Reactor
model. Both the water-gas-shift and the methanation reactions occur in the vapor phase.
For these reactions, CHEMCAD has built-in parameters. You can select either the Shift
reactor or Methanation reactor option in the Reactor Model area of the Equilibrium
Reactor dialog box.
After you select an option, all the required equilibrium data and stoichiometry for the
reaction(s) are stored within the program. These reactions are assumed to take place in
the vapor phase.
This example shows how to enter the required data into a general equilibrium reactor
(first row) and how to specify the reactor type instead (second row).
The entered equilibrium data is the same that CHEMCAD uses for the shift and
methanation reactor. To learn more, press [F1] to open the CHEMCAD help file, then see
the help topic called "Equilibrium Reactor (EREA)."
31
Methanation:
A= -29.3014
B= 26248.4
A= -4.45469
B= 4593.17
Temperature: Kelvin
Pressure: Atm
32
Equilibrium Reactor (EREA)
This simulation compares the resulting equilibrium conversion when changes are made
to the feed composition and conditions.
Two of the most common reactions will be evaluated using the Equilibrium Reactor
model. Both the water-gas-shift and the methanation reactions occur in the vapor phase.
For these reactions, CHEMCAD has built-in parameters. You can select either the Shift
reactor or Methanation reactor option in the Reactor Model area of the Equilibrium
Reactor dialog box.
After you select an option, all the required equilibrium data and stoichiometry for the
reaction(s) are stored within the program. These reactions are assumed to take place in
the vapor phase.
Note: This example is set for the shift reaction only. To simulate the methanation
reactor, include some water in the feed. Also, change the reactor type and change the
number of reactions to 2 (both the methanation and water-gas-shift reactions occur
here; thus simulation is a multi-reaction equilibria problem).
All reactor UnitOps operate isothermally at 826.85 °C. You may choose Adiabatic as the
thermal mode when specifying the reactor.
Reference:
Smith J.M., Van Ness, H.C. & Abbott M.M. "Introduction to Chemical Engineering
Thermodynamics." Seventh Edition, McGraw-Hill. pp. 483-504, Example 13.5 (modified).
33
Kinetic Reactor (KREA)
This example shows an esterification reaction between acetic acid and ethanol to
produce ethyl acetate and water using the Kinetic Reactor model. The reaction takes
place in the liquid phase. The NRTL K-value has been chosen to model the non-ideal
behavior of the mixture.
For this example, the plug flow reactor was chosen as the reactor type. You may switch
to a continuous stirred-tank reactor by selecting the option in the Kinetic Reactor dialog
box.
The first row shows the difference between the thermal modes. In adiabatic mode, no
heat transfer occurs between the reactor and the surroundings. Since this reaction is
exothermic, the temperature of the mixture increases, thus vaporizing the mixture. In
isothermal mode, the temperature is held constant by adding or withdrawing heat from
the reactor. Given the nature of the reaction, heat is removed here.
The second row shows two common ways of improving the yield when using kinetic
reactors. Reactor 3 has twice the volume and reactor 4 operates at a higher temperature
(70 °C).
34
Kinetics of the forward and reverse reactions are considered. The reaction stoichiometry
and kinetic data (frequency factor and activation energy) have been entered for each
reaction.
Review the units for the kinetic expression on the More Specifications tab in the
Reactor dialog box.
To learn more about the Kinetic Reactor model, press [F1] to open the CHEMCAD help
file, then see the help topic called "Kinetic Reactor (KREA)."
35
Heat Exchangers: Principles and Applications
Heat transfer occurs from a warmer fluid to a cooler fluid through a solid wall separating
the two. Heat transfer may be sensible heat--that is, the temperature rises or falls
without any phase change--or latent heat, involving a phase change such as
condensation or vaporization.
This example focuses on heat exchangers and simple fired heater models.
After running the UnitOp, it is useful to plot heat curves for the process stream (and
utility stream, if any). First click any heat exchanger to select it. Then on the Home tab,
in the Results group, click the Charts drop-down and choose Heat Curves under the
UnitOp heading. Select either chart axis option. The first option, temperature vs deltaH,
plots temperature as a function of heat duty. The second option, temperature vs %
length, plots temperature as a function of the % length of the heat exchanger area.
Note: For countercurrent heat exchangers, streams enter the unit from opposite sides.
Sensible heat is transferred: the fluid is cooled or heated without inducing a phase
change. Plot the heat curve and notice the slope of the curve.
Plot the heat curve and notice how the slope flattens as soon as the phase change
begins.
36
c) Fired Heater: Specify outlet temperature. CHEMCAD calculates the heat required and
fuel usage to achieve the change in temperature. This UnitOp is used to heat a large
amount of material before it enters the process. Optional specifications include the
pressure drop and thermal efficiency (default = 75%). The rated heat duty and fuel
heating value are specified when a particular fired heater is rated.
d) Without phase change: The process stream is heated or cooled by using a warmer or
colder fluid, respectively. Specify outlet temperature for either stream. CHEMCAD
calculates the heat duty (only the positive heat duty is reported) and LMTD. Review the
specifications and the heat curves. Plot the heat curves and notice how the slope
continuously increases/decreases for one fluid while the other fluid exhibits the opposite
trend.
e) With phase change: The process stream is heated or cooled by using a warmer or
colder fluid, respectively. Specify outlet temperature for either stream. CHEMCAD
calculates the heat duty (only the positive heat duty is reported) and LMTD. Plot the heat
curves and notice how the slope flattens during the phase change.
Note: In practice, heat exchangers exhibit a pressure drop. Its magnitude depends on
the size of the heat exchanger, as well as the flow rates and temperature change for the
streams exchanging heat.
Note: All UnitOps use simulation mode 0 Enter specifications (CHEMCAD simulation).
With this mode, outlet conditions are calculated based on thermal specifications (e.g.,
outlet temperature, vapor fraction, heat duty). Ideal heat transfer is calculated according
to Q = U*A*LMTD. U is not calculated rigorously. To use any of the other terms, you
need to have a CC-THERM license.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Simple Heat Exchanger" and "Two-sided Heat Exchanger."
37
Heat Exchangers: Use Cases
Heat transfer occurs from a warmer fluid to a cooler fluid through a solid wall separating
the two. Heat transfer may be sensible heat--that is, the temperature rises or falls
without any phase change--or latent heat, involving a phase change such as
condensation or vaporization.
This example demonstrates the use of the two-sided heat exchanger. For all cases,
steam at 300 °F is the utility stream.
Notice the outlet temperature for the utility in all cases. What do you observe?
After running the UnitOp, it is useful to plot heat curves for the process and utility
streams. First click any heat exchanger to select it. Then on the Home tab, in the
Results group, click the Charts drop-down and choose Heat Curves under the UnitOp
heading.
38
Select either chart axis option. The first option, Plot X-axis = DelH, plots temperature as
a function of heat duty. The second option, Plot X-axis = % Length, plots temperature as
a function of the % length of the heat exchanger area.
Note: For countercurrent heat exchangers, as in this example, streams enter the unit
from opposite sides.
Notice the slope for each fluid in the heat curve. Is the slope the same? Does the slope
change at any point?
Note: Heat exchangers on this flowsheet use simulation mode 0 Enter specifications
(CHEMCAD simulation). With this mode, outlet conditions are calculated based on
thermal specifications (e.g., outlet temperature, vapor fraction, heat duty). Ideal heat
transfer is calculated according to Q = U*A*LMTD. U is not calculated rigorously. To
calculate U rigorously from geometry, you need to have a CC-THERM license.
All cases with the exception of case 9 have the utility option turned off. When the utility
option is activated (UnitOp 9), CHEMCAD adjusts the flow rate of an input stream, in this
case the utility, to match the required duty (calculated) of the unit. Using this option
requires two specifications (e.g., outlet temperature for each stream), instead of only
one as in cases 1-8.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Simple Heat Exchanger" and "Two-sided Heat Exchanger."
39
Heat Exchangers: Equipment Design, Sizing, and Costing
After running the UnitOp, it is useful to plot heat curves for the process and utility
streams. First click any heat exchanger to select it. Then on the Home tab, in the
Results group, click the Charts drop-down and choose Heat Curves under the UnitOp
heading.
Select either chart axis option. The first option, Plot X-axis = DelH, plots temperature as
a function of heat duty. The second option, Plot X-axis = % Length, plots temperature as
a function of the % length of the heat exchanger area.
Note: For countercurrent heat exchangers, as in this example, streams enter the unit
from opposite sides.
Notice the slope for each fluid in the heat curve. Is the slope the same? Does the slope
change at any point?
This example shows the various simulation modes for a two-sided heat exchanger.
(1) T for stream 2 and vapor fraction for stream 4 specified, as well as the pressure drop
for both streams. Area (per shell) is specified, thus the heat transfer coefficient U is
calculated. With the selected utility option, CHEMCAD calculates the utility flow rate
(stream 3).
40
(2) Stream 7 is specified with the same steam flow rate as stream 3. The heat transfer
coefficient U is specified (but different from the one calculated for UnitOp 1), thus the
area (per shell) is calculated.
(3) Both U and area (per shell) are specified. This counts as a single thermal
specification and the dialog box is complete. The outlet temperatures are calculated for
both streams.
(4) Cocurrent has been selected as the exchanger type in the Misc. Settings tab.
Countercurrent is most common due to its higher efficiency. You can change the flow
rate of water to 9000 kg/h, run the UnitOp, and then plot the heat curves to appreciate
the difference.
(5) Additional specifications can be entered under the Cost Estimations tab. The option
to run the costing report has been checked for this UnitOp.
Click UnitOp 6 to select it, then on the Sizing tab, in the Heat Exchanger group, click
Shell and Tube to bring up the Shell and Tube Exchanger menu. For this example, no
specifications have been entered in the tabs, so the default settings and values are used
for the calculation. Click General Specifications and change the Calculation Mode
setting to Design.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Two-sided Heat Exchanger" and "Shell and Tube Overview."
41
Heat Exchangers: CC-THERM Modes
This example shows the various simulation modes for a two-sided heat exchanger.
(1) T for stream 2 and vapor fraction for stream 4 specified, as well as the pressure drop
for both streams. Area (per shell) is specified, thus the heat transfer coefficient U is
calculated. With the selected utility option, CHEMCAD calculates the utility flow rate
(stream 3).
(2) Same flow rate as stream 3 is specified for stream 7. The heat transfer coefficient U
is specified (but different than the one calculated for UnitOp 1), thus the area (per shell)
is calculated.
(3) Both U and area (per shell) are specified. This counts as a single thermal
specification and the dialog box is complete. The outlet temperatures are calculated for
both streams.
(4) Rating mode shows us "Can our exchanger give us flowsheet performance?"
Click UnitOp 4 to select it, then on the Sizing tab, in the Heat Exchanger group, click
Shell and Tube. In the Shell and Tube Exchanger menu, select General Specifications
and set Calculation mode to Rating.
For CC-THERM:
Effective Area is "How much area does this unit have for heat transfer?"
42
Area required is "How much area does the unit require to perform the specified heat
transfer?"
Ucalc is calculated from Q=U*A*LMTD using required area, outlet temperatures, and
overall duty.
Uservice represents the heat transfer that would occur if you observe this unit
performing as specified.
Uservice is calculated from Q=U*A*LMTD using effective area, outlet temperatures, and
heat specification for the unit.
In general, if Ucalc < Uservice, the exchanger is not capable of performing the desired
heat transfer.
(6) Shell & tube simulation mode lets you answer the question: "What would happen if
these feeds went through this exchanger?"
(7) Shell & tube fouling factor rating lets you change the fouling until the predicted
temperatures out match reality.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics called
"Two-sided Heat Exchanger" and "Shell and Tube Overview."
43
Recycle: Closing the Loop
CHEMCAD can automatically handle recycle problems by determining recycle cut streams
and unit operation calculation sequence.
On the Home tab, in the Setup group, click Convergence to review the default settings
and/or make changes. Smart Cut allows for faster convergence, but you can choose
Normal recycles if you prefer.
You can override this and specify your own cut streams by going to the Specification
tab and clicking Select from the Cut Streams group. You need to make sure that they
cut the recycle loops completely.
44
Nested Recycle: Closing the Inner Loop
CHEMCAD can automatically handle recycle problems by determining recycle cut streams
and unit operation calculation sequence.
On the Home tab, in the Setup group, click Convergence to review the default settings
and/or make changes. Smart Cut allows for faster convergence, but you can choose
Normal recycles if you prefer.
You can override this and specify your own cut streams by going to the Specification
tab and clicking Select from the Cut Streams group. You need to make sure that they
cut the recycle loops completely.
45
Nested Recycle: Closing the Outer Loop
CHEMCAD can automatically handle recycle problems by determining recycle cut streams
and unit operation calculation sequence.
On the Home tab, in the Setup group, click Convergence to review the default settings
and/or make changes. Smart Cut allows for faster convergence, but you can choose
Normal recycles if you prefer.
You can override this and specify your own cut streams by going to the Specification
tab and clicking Select from the Cut Streams group. You need to make sure that they
cut the recycle loops completely.
46
Flow Models: Input Specifications
This example shows the equipment used to change the pressure of fluids in a process.
Pumps increase the pressure of a liquid stream. When you specify discharge pressure or
pressure increase, CHEMCAD calculates the required work. If efficiency is not specified,
ideal work is calculated (efficiency = 1). Notice how lower efficiency causes the
temperature of the liquid to increase. This is because the additional work (compared to
the ideal) goes into the fluid. Pumping liquid is cheap, and the properties of the fluid are
not changed by much. If there is vapor inside the pump, CHEMCAD will issue a warning
and the pump ID will turn yellow.
Valves decrease the pressure of a fluid, either liquid, vapor, or saturated mixture. The
valve performs an adiabatic flash calculation on the inlet stream at output pressure. The
Joule-Thomson effect describes the temperature change of a fluid as it expands through
the valve. The change in enthalpy is zero and no work is produced. Notice the outlet
temperature of the streams.
Expanders perform the opposite operation by expanding the gas, lowering its
temperature, and generating power as a result.
47
Using the Specify performance curves mode for either the pump or the
compressor/expander allows you to enter the performance curve for the equipment.
Specify performance curve is selected as the UnitOp mode, the speed lines and pump
speed specified, and the curve data entered on the appropriate column of the matrix that
appears when you click OK.
Two calculation options: 1) Fixed flow rate, calculate Pout (used in this example)
calculates the outlet pressure considering the inlet flow rate and the performance curve
data; 2) Pout from downstream uop, calc flow rate requires a downstream unit operation
such as a Node UnitOp (see the "Pressure loop - pump performance curve" example).
CHEMCAD then calculates the flow rate passing through the pump. This is used to
perform hydraulic balance on piping systems.
Equipment costing: On the Cost Estimation tab of the UnitOp dialog box, you can
enter additional specifications, then click Run the costing report after calculating unit.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topics for
the Compressor/Expander, Liquid Pump, and Valve UnitOps, found under UnitOps and
Other Flowsheet Objects > UnitOps > Piping and Flow.
48
Single-branch Piping Configurations
Inlet flow rate and pump outlet pressure are known. CHEMCAD calculates pressure drop
throughout the single branch, resulting in an outlet pressure of 20.81 psia.
The controller varies the output pressure of the pump until the pressure at the outlet is
exactly 20 psia.
49
Add Nodes – Simultaneously Solve for Flow Rate:
Heat exchangers do not scale (change) flow rate to balance pressure drop. For this
reason, the heat exchanger does not need its own nodes.
Nodes are used to measure pressure and hydraulic balances between unit operations on
the flowsheet.
In this example, the pressure at the outlet is known (20 psia), and the inlet flow rate is
calculated as a function of pressure.
To enter the performance curve in the pump dialog box, select Specify performance
curve as the pump mode.
50
Reports: Benzene/Toluene/Xylene Distillation
The purpose of this example is to show the reports that CHEMCAD generates and how to
access them. Follow the instructions below to generate individual reports.
To choose how to display reports, use the Report Viewer drop-down in the Results
group of the Home tab. Change the default report viewer by choosing among
CHEMCAD's internal report viewer, MS Word, MS Excel, and others.
Stream-based reports:
To select the active property set, use the Property Set drop-down in the Results group
of the Home tab. Choose among Quickview, Stream Composition, and Stream Property.
To customize the selected property set, click the gear icon located below the Property
Set drop-down. Then in the Property Set Preferences dialog, use the Properties tab on
the right to choose the stream properties that appear on the report. Click the Help
button to learn more.
51
On the Home tab, in the Results group, click the Reports drop-down. Under the
Stream heading, choose either Select (type in the stream IDs one per line or click on
the streams), All Streams, Feed, Product, or UnitOp (inlet and outlet streams for a
specified UnitOp).
UnitOp-based reports:
On the Home tab, in the Results group, click the Reports drop-down. Under the
UnitOp heading, choose:
1) Select to view UnitOp results. Enter the UnitOp IDs one per line or click on the
UnitOp symbols.
2) Spec Sheet to export detailed information into a pre-formatted Excel worksheet (one
per piece of equipment). This is useful for soliciting a manufacturing quote, for example.
Distillation reports:
On the Home tab, in the Results group, click the Reports drop-down. Under the
Distillation heading, choose either:
2) Tray Composition to list vapor and liquid flow rate, and K-value of each component
on each stage.
3) Tray Properties to list properties such as density, viscosity, and thermal conductivity
for each stage.
Flowsheet-based reports:
On the Home tab, in the Results group, click the Reports drop-down. Under the
Flowsheet heading, choose:
3) Mass and Energy to view mass and energy balances as well as information about
the calculation mode used, convergence, recycle loops, and cut streams, if any.
You can also customize a combination of individual reports. On the Home tab, in the
Results group, click the Reports drop-down. Click Report Writer near the bottom and
choose Consolidated, then select the sections of interest and generate the report.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Output and Reports."
52
Charts: Phase Equilibria
The purpose of this example is to show the charts that CHEMCAD generates and how to
access them.
Note: Charts marked with an asterisk are not available using this example. The feed
streams and Flash UnitOps have been specified to provide representative examples.
Review the specifications and resulting product streams. To learn more, see the
examples in the Phase Equilibria folder.
On the Home tab, in the Results group, click the Charts drop-down. Under the
Thermodynamic heading, choose:
1) TPXY to generate TXY, PXY, and XY diagrams. Specify binary mixture and either
constant temperature or constant pressure. It’s most common to select the more volatile
component first.
2) Binary LLE to generate liquid-liquid equilibrium curves between any two components.
An activity coefficient method should be selected as the K-value model and
53
Vapor/Liquid/Liquid/Solid should be selected as the Global Phase Option in the
Thermodynamic Settings dialog (Home tab, Setup group).
3) Binary SLE to generate solid-liquid equilibrium curves between any two components.
Vapor/Liquid/Liquid/Solid should be selected as the Global Phase Option in the
Thermodynamic Settings dialog (Home tab, Setup group).
4) Binodal to generate a ternary phase diagram that shows the component distribution
in the two liquid phases. Enter the ternary mixture and temperature.
5) Residue Curves to display distillation zones, azeotropes, and residue curves. Specify
ternary mixture and pressure.
6) Binodal/Residue Curves to combine the curves from a binodal chart and residue
curve chart. This is useful for heterogeneous azeotropic distillation. The order in which
you select the components determines the edges of the equilateral triangle chart.
Note: The first component becomes the left edge, the second component the right edge,
and the third component the base.
Note: For the Binodal chart to be generated, the first and third components should form
two liquid phases.
Click any stream to select it. Then on the Home tab, in the Results group, click the
Charts drop-down. Under the Stream heading, choose:
1) Stream Properties to plot one selected stream property (e.g., vapor pressure,
density, viscosity) as a function of temperature. Specify the temperature range, then
click OK.
2) Phase Envelopes to plot a phase envelope. The text report includes tabulated data
and Tc, Pc, Zc values for the mixture. The critical point of the mixture is indicated.
Results at vapor fractions other than 0 and 1 can be included.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Output and Reports."
54
Charts: Benzene/Toluene Distillation
In this example, a mixture of benzene and toluene is separated by distillation. The Tower
distillation model was used to perform rigorous calculations. The two columns shown
have different specifications and performance.
To learn how to build this example, see the example called _Process Simulation
Essentials\3 Separators\4 - Distillation column performance. The purpose of this
example is to show the charts that CHEMCAD generates and how to access them.
Note: Charts marked with an asterisk are not available using this example.
On the Home tab, in the Results group, click the Charts drop-down and choose TPXY
under the Thermodynamic heading. Specify the binary mixture and either constant
temperature (or constant pressure). It’s most common to select the more volatile
component first. Then check the boxes on the right to generate PXY (or TXY) and XY
diagrams.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
LLE under the Thermodynamic heading. CHEMCAD will tell you that benzene and
toluene are miscible, and thus only one liquid phase exists.
The Binodal chart is not available because these components do not form two liquid
phases. The Residue Curves chart is not available because this is a binary mixture.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
SLE under the Thermodynamic heading. Enter the binary mixture.
55
To plot heat curves for the condenser and reboiler, first click either column to select it.
Then on the Home tab, in the Results group, click the Charts drop-down and choose
Heat Curves under the UnitOp heading.
To plot profiles for either column, first click the UnitOp to select it. Then on the Home
tab, in the Results group, click the Charts drop-down and choose Column Profiles
under the UnitOp heading.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Output and Reports." The "Graphical Reports" section of this topic addresses charts.
56
Charts: Exchangers and Plug Flow Reactor
In this example, acetic acid and ethanol react to form ethyl acetate and water according
to the reversible esterification reaction. The reaction takes place in the liquid phase, and
the NRTL K-value has been chosen to model the non-ideal behavior of the mixture.
In addition, the Plug Flow Reactor was chosen as the reactor type. The purpose of this
example is to show the charts that CHEMCAD generates and how to access them.
Note: Charts marked with an asterisk are not available using this example.
On the Home tab, in the Results group, click the Charts drop-down and choose TPXY
under the Thermodynamic heading. Specify the binary mixture and either constant
temperature (or constant pressure). It’s most common to select the more volatile
component first. Then check the boxes on the right to generate PXY (or TXY) and XY
diagrams.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
LLE under the Thermodynamic heading. CHEMCAD will tell you that acetic acid and
ethanol are miscible, and thus only one liquid phase exists.
On the Home tab, in the Results group, click the Charts drop-down and choose
Binodal/Residue Curves under the Thermodynamic heading. Enter the ternary mixture
and specify pressure.
57
Note: The Binodal chart is not available because these components do not form two
liquid phases.
On the Home tab, in the Results group, click the Charts drop-down and choose Binary
SLE under the Thermodynamic heading. Enter the binary mixture.
For both heat exchangers, the utility option is active, allowing CHEMCAD to determine
the utility flow rate provided two thermal specifications. The first heat exchanger is
specified as countercurrent, while the second is specified as cocurrent (see the Type
specification on the Heat Exchanger dialog’s Misc. Settings tab). The heat curve will
change depending on what type is selected.
To plot heat curves for either heat exchanger, first click the UnitOp to select it. Then on
the Home tab, in the Results group, click the Charts drop-down and choose Heat
Curves under the UnitOp heading. For more on heat exchangers, see the see the
examples in _Process Simulation Essentials\5 Heat Exchangers.
The Plug Flow reactor is adiabatic, so no heat transfer occurs between the reactor and
the surroundings. Since this reaction is exothermic, the temperature of the mixture
increases.
Kinetics of the forward and reverse reactions are considered. The reaction stoichiometry
and kinetic data (frequency factor and activation energy) have been entered for each
reaction.
Review the units for the kinetic expression by clicking the More Specifications tab in
the Reactor dialog box. For more on reactors, see the examples in _Process
Simulation Essentials\4 Reactors.
To look at the reactor profiles, first click UnitOp 2 to select it. Then on the Home tab, in
the Results group, click the Charts drop-down and choose Plug Flow Reactor Profile
under the UnitOp heading. Select the components and independent variable of interest.
For example, plot moles of both acetic acid (reactant) and ethyl acetate (product) vs
reactor volume (axial length), and include temperature (check the option).
To learn more about charts, press [F1] to open the CHEMCAD help file, then see the
help topic called "Output and Reports." The "Graphical Reports" section of this topic
addresses charts.
58
Tools: UnitOps
This example shows several of CHEMCAD's utility tool UnitOps, which are used in
building and running flowsheets. Familiarize yourself with basic use of CHEMCAD as
demonstrated in the earlier CHEMCAD Essentials examples before using these UnitOp
tools.
The Flash button on a stream dialog allows for a quick flash calculation. Define the
stream by specifying composition and two variables (T, P, or vapor fraction), then click
the Flash button located at the upper left corner of the Edit Streams dialog box. For
example, specify Stream 1 vapor fraction = 0.5 and P = 1 bar. Clicking Flash will show
you the temperature at this condition. Transport properties can be seen in the stream
properties report, or by hovering over the stream line with the Flowsheet Quickview
feature turned on.
In Feed-backward mode, the controller behaves as a solver routine. In this example, the
controller (2) adjusts the thermal specification inside the heater (i.e., temperature out)
until the vapor fraction of stream 3 is 50% vaporized. The controller will change the
adjusted variable and run UnitOps until stream 3 reaches the 50% vapor target, then
determine if the solution has been found.
59
To learn more, click the Help button in the Controller dialog box, or see the controller
examples in _Process Simulation Essentials\9 Tools. A separate PID controller
UnitOp is available for dynamic simulations.
This UnitOp can transfer stream information to another process stream (i.e., a feed or an
isolated stream). It should be placed downstream of the UnitOp that calculates the
information to be passed. Various modes and transfer options are available, which can
be reviewed by clicking the Help button in the Stream Reference dialog box.
For this example, the stream reference (3) passes stream information from stream 5 to
stream 7.
Node UnitOp:
Nodes are used to measure pressure and perform hydraulic balances between unit
operations on the flowsheet. They are placed upstream and downstream of pipes,
pumps, and control valves in piping systems. For this example, the nodes facilitate the
pressure drop calculation across the pipe. To see other examples where nodes are used,
go to the My Simulations directory, and in your examples subdirectory, find the Piping
folder.
60
Tools: META UnitOp
This example shows one of CHEMCAD's UnitOp tools, which is used in building and
running flowsheets. We do not recommend using this tool if you have only recently
started using CHEMCAD.
It is not unusual for multiple flowsheets to model various parts of a process. Integrated
flowsheets may be too large and complicated to handle. In addition, these flowsheets
may have different components and thermodynamics. The subflowsheet unit operation
(META UnitOp) sends stream data to a second flowsheet (child simulation), runs it, and
returns data to the parent flowsheet.
This example sends data to a simulation called "2.2 - META unit - child simulation",
stored in the same location as this simulation.
The META UnitOp requires the specification of inlet and outlet streams for both the
parent and child simulations, as well as the path for the child simulation, which you can
generate by browsing for the file of interest.
To learn more, press [F1] to open the CHEMCAD help file, then see the help topic called
"Subflowsheet Unit Operation (META)."
Note: The META UnitOp can only run using the sequential modular calculation sequence.
61
Tools: Child Simulation for META UnitOp
The purpose of this flowsheet is to serve as the child simulation for the simulation called
"2.1 - META unit - parent simulation", stored in the same location as this simulation.
The META UnitOp defines the feed stream (stream 1), runs this simulation, and sends
the product stream (stream 3) back to the parent flowsheet.
62
Tools: Sensitivity Analysis
In this example, a mixture of benzene and toluene is separated by distillation. The Tower
distillation model is used to perform rigorous calculations. The goal is to obtain the
highest benzene purity and recovery in the distillate.
To review the column results, first right-click Tower 4 to bring up the UnitOp menu. Click
Plot Column Profile or View Column Profile to see the data in chart or tabular
format.
63
The next step is to investigate the effect of changing a parameter or specification. This
activity can be carried out automatically using the Sensitivity Analysis feature. Sensitivity
analyses help us investigate the best parameters for a column that has 20 stages.
Note: This tool enables you to test multiple cases efficiently, but it does not give you the
optimum answer. However, the reports and charts can help you decide the best
operation based on design specifications, operational constraints, or economics.
This simulation includes three sensitivity analyses, designed to find the best operating
parameters for the column. To view the analyses, first click the Analysis tab, then select
an item from the Sensitivity group drop-down.
The analysis named "FeedLoc" varies the feed stage location from stage 2 to stage 19. It
records the mole fraction and mole rate of benzene in the distillate.
The analysis named "Reflux" varies the reflux ratio specification from 1 to 15. It records
the condenser and reboiler duties, as well as the mole fraction and mole rate of benzene
in the distillate.
The analysis named "2variables" varies the column pressure drop from from 0 to 5 bar
and the bottoms mole flow rate from 10 to 70 kmol/h. It records the bottoms
temperature, as well as the mole fraction and mole rate of benzene in the distillate.
Note: Each independent variable is treated separately. This tool cannot find correlations
between the parameters. It sets the bottom flow rate at 10 kmol/h and varies the
pressure drop. Then it changes to 20 kmol/h and repeats for each value of pressure
drop.
To review or modify the settings for the selected analysis, click Edit Sensitivity
Analysis. Click OK to close this dialog.
To run the selected analysis, click Run All. Upon completion, click Plot Results or
Report Results to see the data in chart or tabular format.
64
Controller: Simple Applications
The Controller UnitOp behaves as a solver routine. The feed-backward mode, shown in
this example, adjusts one variable (from an equipment or a stream) until the measured
variable equals the setpoint. Scaling is allowed. The setpoint can be an algebraic
calculation of two measurements.
In other words, the controller compares the measured variable to a setpoint and decides
a new value for the adjusted variable until the specified condition is achieved.
Adjust this variable: Specify UnitOp or stream ID, the adjusted variable and its unit,
and the lower and upper bounds (do not enter if you are not sure).
Until this: Specify UnitOp or stream ID, the specification variable, and any scaling or
arithmetic operation (optional).
Note: By default, CHEMCAD's default units are used (i.e., 0 Internal unit). If any options
are selected, the flowsheet global units are used for this constant.
To learn more, click the Help button located at the bottom left corner of the Controller
dialog box.
For more on CHEMCAD's default units, see the help topic called "Neutral File Import of
Component Properties." Under the Dimensional Data section, see the first line for each
table of units.
65
Controller: Refrigeration Cycle
This example shows a simple refrigeration cycle and the use of CHEMCAD's Flash
command and Controller UnitOp.
The goal is to cool 90,000 kg/h of process water from 27 °C to 12 °C. Water is used as
the refrigerant.
The isolated stream is used to perform a quick flash calculation to get the temperature
estimates. Specify amount, composition, pressure, and vapor fraction for the stream,
then click the Flash button in the upper left corner of the Edit Stream dialog, to calculate
temperature and enthalpy.
66
Guess an amount of refrigerant and specify P = 1 kPa and vapor fraction = 0 to get the
saturation temperature.
Stream 3: Saturated water flashes through a valve, which reduces the pressure back to
1 kPa.
The water that needs to be cooled down also passes through the evaporator, thus
exchanging heat with the refrigerant.
The cycle is closed when streams 1 and 5 have the same properties.
Note: The amount of process water is known, as well as its required outlet temperature.
The amount of refrigerant, however, is unknown.
For this example, a guess of 1,000 kg/h of refrigerant was used to run the simulation. To
have the same properties in streams 1 and 5, the temperature of stream 5 was specified
to be 7 °C in the heat exchanger. Because the temperature of the refrigerant is
specified, the temperature of the process water is allowed to vary. Here the specification
is not met when a mass flow rate of 1,000 kg/h is used.
Instead of guessing the mass flow rate of refrigerant, a feed-backward controller is used.
The controller "looks" at the temperature of stream 15 and manipulates the mass flow
rate in stream 9 until the temperature of stream 15 is effectively 12 °C. Once the
controller converges, the mass flow rate of refrigerant that results in an outlet
temperature of 12 °C for the process water is replaced in the feed stream specification
dialog box.
Note: this example is actually a closed cycle. However, closing the loop requires streams
9 and 13 to be very close beforehand. DO NOT attempt to draw a flowsheet from scratch
with the loops closed. It is recommended to leave the flowsheet with the loop open to
avoid convergence problems or convergence to a different solution.
Reference: Example modified from Abbott, M. M. & Van Ness, H. G. (1989). Schaum's
Outline of Thermodynamics with Chemical Applications. New York, Mc-Graw-Hill, p. 311.
67
Controller: Separators
The Controller UnitOp behaves as a solver routine. The feed-backward mode, shown in
this example, adjusts one variable (from an equipment or a stream) until the measured
variable equals the setpoint. Scaling is allowed. The setpoint can be an algebraic
calculation of two measurements.
In other words, the controller compares the measured variable to a setpoint and decides
a new value for the adjusted variable until the specified condition is achieved.
Adjust this variable: Specify UnitOp or stream ID, the adjusted variable and its unit,
and the lower and upper bounds (do not enter if you are not sure).
Until this: Specify UnitOp or stream ID, the specification variable, and any scaling or
arithmetic operation (optional).
Note: By default, CHEMCAD's default units are used (i.e., 0 Internal unit). If any options
are selected, the flowsheet global units are used for this constant.
68
To learn more, click the Help button located at the bottom left corner of the Controller
dialog box.
For more on CHEMCAD's default units, see the help topic called "Neutral File Import of
Component Properties." Under the Dimensional Data section, see the first line for each
table of units.
69
CHEMCAD
User Guide
All material © 2021 Chemstations, Inc.
CHEMCAD User Guide
Table of Contents
Distillation ............................................................................................................................................. 98
Flowsheet ............................................................................................................................................... 99
Dynamic ............................................................................................................................................... 100
UnitOp and Stream Groups .................................................................................................................. 100
Creating a Group ................................................................................................................................ 100
UnitOp and Stream Group Commands .......................................................................................... 101
Choosing Groups in the Select Streams and Select UnitOp Dialogs ........................................... 102
Report Viewer Setup.............................................................................................................................. 102
Printing CHEMCAD Reports and Charts .......................................................................................... 103
Consolidated Reports and the CHEMCAD Report Writer .............................................................. 103
Choosing and Ordering Report Sections ........................................................................................ 104
Selecting Flowsheet Elements ........................................................................................................... 105
Formatting Report Sections............................................................................................................... 105
Naming the Report and Choosing a Destination ........................................................................... 106
Selecting a Report Viewer for Consolidated Reports .................................................................... 107
Property Sets ........................................................................................................................................... 107
Built-in Property Sets ......................................................................................................................... 107
User-created Property Sets ................................................................................................................ 107
Different Sets for Different Purposes ............................................................................................... 107
The Property Set Preferences Dialog ............................................................................................... 108
Active Set Designations ..................................................................................................................... 109
Editing a Property Set ........................................................................................................................ 109
Creating a New Property Set ............................................................................................................ 109
Copying an Existing Property Set .................................................................................................... 110
Format Tab Options ........................................................................................................................... 111
Resetting Built-in Property Sets........................................................................................................ 111
Deleting a User-added Property Set ................................................................................................ 111
Using the Property Set Library ......................................................................................................... 111
Sharing Property Sets with Other CHEMCAD Users ................................................................... 113
Creating Process Flow Diagrams ......................................................................................................... 113
Adding Flowsheet Databoxes ........................................................................................................... 113
Using Title Blocks ............................................................................................................................... 117
Using the Layers Feature for Selective Viewing and Printing ..................................................... 119
Printing a Process Flow Diagram ..................................................................................................... 122
Welcome to CHEMCAD, a powerful and effective software tool for chemical process
simulation. Whether you’re a new or experienced CHEMCAD user, you’ll appreciate
the program’s user-friendly, feature-rich interface. Creating flowsheets and running
simulations is fast and easy with CHEMCAD, and the program is highly
customizable to fit your needs and the way you work.
This User Guide will help you get up and running with CHEMCAD, from
installation and licensing to details on using dynamics and data interfaces.
CC-STEADY STATE
The main CHEMCAD product, known as CC-STEADY STATE, enables you to
design new processes, rate existing processes, and optimize processes in steady state.
CC-DYNAMICS
The module known as CC-DYNAMICS makes it possible to design new and rate
existing processes using a dynamic simulation. This module is fully integrated with
CHEMCAD to make switching between steady state and dynamics easy and
intuitive. Using CC-DYNAMICS, you can easily simulate everything from simple
vessel accumulation to complex control systems on columns. This module also
provides tools for simulation of continuous stirred-tank reactors (CSTRs), including
complex reaction rate and pressure calculation.
CC-BATCH
The CC-BATCH product enables you to design, rate, or optimize a batch distillation
column. CC-BATCH includes a scheduling interface to allow an “operation step”
approach to simulation of batch columns.
CC-THERM
The CC-THERM product lets you design a single heat exchanger, or vet a vendor’s
heat exchanger design. It is also ideal for customers who want to rate existing
exchangers in new service, or to perform calculations on hypothetical situations. CC-
THERM can simulate shell-and-tube, air-cooled, plate-and-frame, and double-pipe
exchangers. Full integration with CHEMCAD makes it possible to calculate exit
conditions from exchanger geometry for high-fidelity simulations.
CC-SAFETY NET
The CC-SAFETY NET product provides the capability to design or rate piping
networks and safety relief devices and systems, in both steady-state and dynamic
systems. The steady-state features of CC-SAFETY NET are included with CC-
STEADY STATE. This product enables users to make simultaneous flow- and
pressure-balanced simulations—even in reverse-flow situations—for single- or
multi-phase flow.
CC-FLASH
The CC-FLASH module provides physical property and phase equilibrium data, as
well as property prediction and regression. CC-FLASH is a subset of CC-STEADY
STATE, and is meant for customers who do not need full flowsheet simulation tools.
CC-STEADY STATE
CC-SAFETY NET
CC-DYNAMICS
CC-THERM
CC-BATCH
CC-FLASH
VB/COM/OPC/Data Map
Sensitivity/optimization
Sizing (line/valve/orifice/vessel)
Run steady state
Run dynamics
Run recycles
Costing
Reconciliation
Sizing columns
Sizing heat exchangers
Economics
Reports (incl. Excel)
DIERS
CO2 solid
Hydrates
Depress
TOC/COD
Pure regression
BIP regression
Electrolyte regression
Rate regression
Units calculator
Execute parser
Environmental report
Simple calculator
Spec sheet
UnitOps by Module
The availability of certain unit operations, or UnitOps, in CHEMCAD simulations is
a function of which modules you have licensed. The following matrix lists all
available UnitOps and the CHEMCAD modules associated with them.
CC-STEADY STATE
CC-SAFETY NET
CC-DYNAMICS
CC-THERM
CC-BATCH
CC-FLASH
Baghouse filter
Batch column
Calculator
Centrifuge
Component separator
Compressor
Control valve
Controller
Crusher/grinder
Crystallizer
Cyclone
Divider
Electrostatic precipitator
Equilibrium reactor
Excel unit
Expander
Fired heater
Flash
Gibbs reactor
Heat exchanger
Hydrocyclone
Kinetic reactor
Liquid/liquid extractor
LNGH exchanger
Loop
Membrane
Mixer
CC-STEADY STATE
CC-SAFETY NET
CC-DYNAMICS
CC-THERM
CC-BATCH
CC-FLASH
Node
PID controller
Pipe simulator
Polymer reactor
Pump
Ramp controller
Relief device
Run subflowsheet META unit
SCDS distillation column
Screen
Sedimentator
Shortcut column
Solids dryer
Solids washer
Stoichiometric reactor
Stream reference
Tank
Time delay
Time switch
Tower distillation column
Tower plus distillation column
User-added module
Vacuum filter
Valve
Venturi scrubber
Vessel
Vessel reactor
To start using CHEMCAD, you’ll need to obtain the software, install it on your
computer, and set up a valid software license. This chapter provides step-by-step
instructions for these tasks.
Before you begin, please ensure that your PC meets the recommended system
requirements, as listed below. It’s also a good idea to find out whether your copy of
CHEMCAD will rely on a
network license; if it will, make
CHEMCAD System Requirements sure to ask your network
Processor: 1 GHz or faster, 32- or 64-bit administrator for all the
Operating system: Windows 7 or later information that you’ll need
(all 32- and 64-bit versions) when installation is complete
RAM: 1 GB for 32-bit, or 2 GB for 64-bit and it’s time to set up
Video card: DirectX 9 graphics device with licensing.
WDDM 1.0 or higher driver
If you’ll be using a
Display resolution: 1920 x 1080 or higher
hardware dongle to license
Hard disk space: 16 GB (32-bit) or 20 GB (64-
CHEMCAD, make sure the
bit) for installation, 1 GB free space
recommended dongle is inserted into a USB
Productivity software: Some features require port before you attempt to run
Mi ft Offi ® the program.
To obtain the CHEMCAD
installation file, you’ll need a live Internet connection and a web browser. You can
either download the file directly onto the system where you plan to install
CHEMCAD, or download the file and place it onto a portable drive for installation
on a different computer. In either case, the download process requires that you log
into Chemstations’ User Support Center.
Figure 2-01: Clicking the Forgot your password? button on the login screen
3. On the next screen, enter a valid e-mail address, and click the Send button. Be
sure to use your company address, as the login system will match your address
against our customer database.
4. If your address is found, you will receive an e-mail from CHEMCAD Technical
Support, offering a link to reset your password. Follow the instructions in the e-
mail and at the password reset screen to complete your registration.
Note: In the event you do not receive a password reset e-mail within 24 hours, your
address may not have been found in our database. Please contact Chemstations
Technical Support (support@chemstations.com) for assistance.
Click Next to begin the installation process. The License Agreement screen
appears, listing the terms of the CHEMCAD standard license. Once you’ve read and
understood the license terms, you’ll need to click the I accept the terms in the license
agreement button before you can click Next to proceed. Note that you have the option
to print a copy of the license agreement from this screen.
The Destination Folder screen appears next, displaying the name of the folder
into which the CHEMCAD files will be installed by default. Normally, this
destination is C:\Program Files\Chemstations\CHEMCAD (or some variation, based
on your version of Windows), and it is recommended that you use this location
unless you have a specific need to install the program elsewhere. Click the Change
button if you want to change the file destination, or click Next to accept the
suggested destination and proceed.
The Setup Type screen now appears, offering a choice between complete and
custom installation. Each type of installation is described on the screen. Either accept
the default setting of Complete or click Custom to select specific components to
install, then click Next to proceed.
This brings you to the Ready to Install the Program screen. Note that on this
screen, and in fact on any screen in the installation process, you can click Back to
return to a previous screen and verify or change your installation options. If you are
satisfied with your settings as they are, click Install to start the installation.
The Installing CHEMCAD Suite screen appears, showing the progress of your
installation with a green status bar.
During installation, you may notice a second, smaller installation window that
pops up. This shows the progress of various software components that are being
found and installed so that CHEMCAD installation may proceed. To ensure
successful completion of the install procedure, be sure to leave this window open; it
will close automatically when all components are in place.
When installation is complete, you’ll see one final screen, which states that the
InstallShield Wizard has completed installation of the CHEMCAD Suite. Click
Finish to close the installer window.
Licensing CHEMCAD
Before you can use CHEMCAD, you’ll need to set up a licensing scheme of some
type. Depending on your particular licensing agreement, you will use one of several
types of licenses to run CHEMCAD.
License Settings
To run CHEMCAD for the first time, make sure that your dongle (if applicable) is
plugged in properly, and then start the program. From the Windows Start menu,
select All Programs > Chemstations > CHEMCAD NXT.
Note: A Standard License screen appears only the first time that you run
CHEMCAD after installation. After you have reviewed the license agreement, click
Yes to continue.
The program opens, displaying a CHEMCAD splash screen. After a short time,
this screen is replaced by the CHEMCAD License Monitor dialog box, which
displays information about the license(s) that your computer is using to run
CHEMCAD.
Figure 2-10: The CHEMCAD License Monitor, displaying licenses from a local hardware dongle
Note: In some cases, this dialog may initially display with the title Searching for
Licenses, indicating that CHEMCAD has not yet detected a valid license. If your
computer is experiencing slow communication with the license server system,
CHEMCAD may simply need more time to detect the license(s). As soon as any
valid license is found, the CHEMCAD License Monitor title will appear and licensing
will proceed.
Normally, this dialog box remains in view for only a few seconds, listing all
product licenses that CHEMCAD has obtained. During that time, you can click
anywhere in the dialog box to keep it open. If you do not click in the dialog box, it
disappears from view, but you can bring it back up at any time by clicking the File
tab and then selecting Licensing.
While the CHEMCAD License Monitor dialog box is open, you can view the
various CHEMCAD licenses detected for your system and see what method (and
where applicable, which server) is being used to obtain those licenses. If your
organization uses RMS License Manager or a SuperProNet hardware key, you can
also see which other users currently hold various product licenses.
For network licenses, you can right-click a server name under a particular
product and select a licensing preference (on demand, always, or never) as shown
below.
You can use the always or never setting to turn licensing for a product absolutely
on or off, respectively. The on demand setting secures a license only when you begin
to use a specific CHEMCAD feature controlled by a certain product. This setting is
ideal in most situations, as it leaves unused licenses available for other users.
To close the CHEMCAD License Monitor screen, click the Continue button, or
click the X in the top right corner of the screen.
Updating a License
CHEMCAD dongles require re-programming on a regular basis—either once a year
or more often, depending on your licensing agreement. This is a security measure to
reduce the likelihood that your dongle will be stolen and misused.
The dongle that you use is programmed to work only through the licensed time
period, and when that time has elapsed, the dongle must be updated before you can
continue using CHEMCAD.
Updating a dongle is a relatively simple procedure. Before your license
expiration, you or your software administrator should receive an e-mail from
Chemstations, with what’s known as a configuration file included as an attachment.
You should save this file to your Windows desktop as soon as you receive it.
Note: If you’ve updated the same dongle in the past, the new configuration file
should have the exact same file name as the previous one. If, while saving the file to
your desktop, you see a Windows message about an existing file with the same
name, you should overwrite the old file (which in any case cannot be used again),
replacing it with the new one.
It’s important to ensure that your configuration file matches your dongle. The
configuration file should be a .DNG file whose name includes a four- or five-digit
code; this code must match the number stamped onto your dongle. If the numbers
2. Click Setup to bring up the License Setup dialog box, then click Update
dongle as shown below.
Figure 2-13: Clicking Update dongle within the License Setup dialog box
3. The dialog box now lists all licensing dongles and displays a field for
entering the full path and file name for the dongle update file. Click Browse
to navigate to the update file.
4. In the Open dialog box, navigate to the location where you saved the .DNG
configuration file. Normally, this is the Windows desktop; if you saved your
configuration file there, click Desktop to tell CHEMCAD where to look for
the file, then select the .DNG file and click Open.
5. The License Setup dialog box now displays the directory path and file name
for the selected .DNG file. Click OK to update the dongle.
Figure 2-15: Updating the dongle with the selected update file
Online Help
At any time while running CHEMCAD in an active window, you can press the [F1]
key to bring up the CHEMCAD Help screen that’s most appropriate to the task you
are currently performing or the dialog box currently displayed.
In some situations, pressing [F1] will bring up the main CHEMCAD Help
window instead of a particular help screen. From there, you can click the Contents,
Index, or Search tab in the upper left corner of the CHEMCAD Help window, and
use these tools to find the information you need.
You can also go directly to the main CHEMCAD Help window by clicking Help
in the top right corner of the program screen. Regardless of how you open
CHEMCAD Help, it always opens in a separate window that does not interfere with
the operation of the CHEMCAD program.
This chapter takes you on a tour of the CHEMCAD screen, including the tabbed
command ribbon, the main areas of the screen, and the flowsheet drawing tools. It
also shows you some ways that you can customize the screen and various features so
that they best suit your own way of working.
Command ribbon
Explorer pane
Workspace
Palette pane
Messages pane
Status bar
Figure 3-01: The full CHEMCAD program window
Note that the File tab behaves differently than the other tabs. Clicking this tab
brings up a list of commands that are applied at the file or program level, including
opening, closing, or saving a simulation; printing a flowsheet or simulation notes;
and setting up licensing and various program preferences. It’s a good idea to take a
few minutes to familiarize yourself with these commands as you begin to work with
the program.
The Workspace
The area in the middle of the screen is known as the workspace. This is the main focus
of the CHEMCAD window, the place where you’ll build and edit flowsheets, view
charts and reports, and run and tweak process simulations.
When you first launch CHEMCAD, the workspace is empty. When you start to
build a flowsheet or open an existing simulation, the flowsheet displays in the
workspace.
The workspace uses tabs to enable you to switch between an open simulation and
any related features, such as Excel Data Maps, reports, and charts. At the bottom of
the workspace area, you’ll see one or more tabs whenever a simulation is open.
Each workspace tab includes a button marked with an X; to close any tab, simply
click that tab’s X button.
Figure 3-04: The bottom of the workspace area, showing several tabs and their X buttons
Note that any time you’ve closed a simulation and haven’t yet opened another
file, the workspace displays as an empty space.
The Explorer pane tabs are presented in a tree format, with items organized into a
multi-level hierarchy. The default view shows only top-level items, but you can
expand each item to view second-level items, third-level items, and so forth.
At the left of each top-level item is a small triangle that points to the right. To
expand an item, click the triangle. Two things happen simultaneously when you
click: the tree expands to show that item’s contents, and the triangle shifts to point
downward. You can hide (or collapse) the lower-level items again by clicking the
triangle again. Figure 3-06 shows an example of an Explorer item in collapsed and
expanded view.
Figure 3-06: Clicking to expand an item (left); the resulting view (right)
Expanding and collapsing items in the Explorer tabs is one way that you can
make the best use of your screen space when working in CHEMCAD.
Selecting a Palette
To select a palette, simply click its title bar. The selected palette expands in place, as
shown in Figure 3-07.
Figure 3-08: A Tower Plus icon in (left to right) Grayscale, System Color, and Wireframe color
schemes
You can apply a color scheme to any UnitOp palette, to determine the
appearance of any new UnitOps you add from that palette to a flowsheet.
Before you apply a color scheme to a palette, first ensure that the desired palette
is open. Then click the current color scheme name, which is displayed next to the
palette name; this will cause a selection list to drop down. Simply click a color
scheme name to switch to that scheme.
Once you have applied a color scheme to a palette, the icons you drag from that
palette onto the flowsheet will look just like the examples on the palette. Changing
the color scheme of a palette does not affect any icons previously added to the
flowsheet from that palette.
Note: Before you attempt to rearrange symbols on a palette, make sure that the Lock
Palette feature is turned off. Normally, this setting protects you from unintentionally
moving symbols around when you are placing items onto a flowsheet.
To turn the feature on or off, right-click any palette’s title bar and look for the Lock
Palette menu item. A check mark indicates that the feature is turned on; simply click
to clear the check mark and unlock all palettes. It’s a good idea to return palettes to a
locked state when you are not actively editing them.
To move a UnitOp symbol to a new location on the palette, click and drag the
symbol. Release the mouse button when the symbol is situated where you want it.
Other symbols on the palette will shift their positions to make room for the newly
placed item.
off the top edge of the pane. If needed, you can use the vertical scroll bar on the right
side of the pane to scroll up and review earlier messages.
To clear all messages from this tab, right-click anywhere within the tab and click
Refresh Errors and Warnings.
Resizing a Pane
The simplest way to alter the appearance of a pane is to resize it. You can make the
Explorer and Palette panes wider or narrower, or make the Messages pane shorter or
taller, by moving the inside edge, or wall, of the pane toward or away from the edge
of the main window.
To resize a pane, start by positioning your mouse cursor at the inside wall of the
pane—that is, the right edge of the Explorer pane, the left edge of the Palette pane, or
the top edge of the Messages pane. When the cursor is in the correct position for
resizing, the normal pointer will be replaced with a two-headed arrow as shown in
Figure 3-09.
Figure 3-09: The two-headed arrow cursor used for resizing panes
When you see the two-headed arrow, click and drag in the direction you want to
move the pane wall. A thick gray line shows a preview of the new pane size; when
you release the mouse button, the resized pane appears.
Moving a Pane
In addition to resizing, you can also move any of the panes in the CHEMCAD
window, either to a different edge of the screen or to the middle of the screen.
Initially, all the panes are docked, meaning that they are “snapped into” an edge
of the screen. When you undock a pane, you can put it in the location of your choice,
away from the screen edge.
To undock a pane, click and drag the pane’s title bar, that is, the bar at the top of
the pane that shows the pane name. Release the mouse button when the pane is in
the desired location.
CHEMCAD User Guide 27
The CHEMCAD Interface
Figure 3-10: The Explorer pane, undocked and moved onto the workspace
You can also dock a pane to a different edge of the screen. To do this, click the
pane’s title bar and begin to drag it away from its current location. A selection box
appears near the center of the workspace, showing all available docking locations.
When your mouse cursor points at any of these docking icons, the corresponding
area of the screen will be highlighted, as shown in Figure 3-xx. Release the mouse
button to dock the pane to that location.
If you click the pin icon, the pane suddenly disappears from view—but it isn’t
gone. Instead, a small tab bearing the name of the palette appears at the edge of the
screen where the pane is docked. To see the pane reappear, you only have to roll
your mouse over that tab. When the pane appears, you’ll notice that the pushpin
icon is now horizontal. Use the tools on the Explorer or Palette normally; then, when
you no longer need the pane, just move the mouse pointer elsewhere. The pane will
automatically hide itself until the next time you roll the mouse over the tab.
Figure 3-13: An unpinned pane in use; note the horizontal pin icon and the Explorer tab at left
To re-pin an unpinned pane, point to the tab to make the pane appear and then
click the pin icon. The pin turns so that it is once again upright, and the pane is once
again a permanent fixture on the CHEMCAD screen.
You can turn on a visible workspace grid to use as a guide while creating your
flowsheet. Click Show Grid to toggle this feature on or off.
The option called Snap to Grid can help with alignment of objects on the
flowsheet. When this option is turned on, items that you move on the workspace will
align themselves with the nearest vertical and horizontal grid lines.
The Snap to Center feature helps you to neatly line up flowsheet elements
relative to one another. When this option is turned on, items that you move around
on the workspace will show when they are centrally aligned with nearby objects, as
indicated by a blue dotted line.
Figure 3-15: The Snap to Center feature in action, showing when objects are centrally aligned
Selecting Change Grid Size brings up the Grid dialog box, which enables you to
customize the look and spacing of the grid lines when the visible grid is turned on.
The Stream Styles tool enables you to customize the way that stream lines
appear on the flowsheet. The Stream Styles dialog includes settings for stream line
width and arrow size, as well as for the behavior of stream intersections. A full
discussion of stream intersections and the use of the Stream Styles settings is
included in Chapter 5, Building and Using a Basic Simulation.
The Font tool enables you to change the appearance of text on flowsheet objects.
If you click Font with one or more flowsheet objects selected, the settings you choose
for size, style, and so forth will apply only to those objects. If you click Font with no
30 CHEMCAD User Guide
The CHEMCAD Interface
objects selected, the font properties you set will apply to future flowsheet objects that
display text.
The Stream Box, UnitOp Box, TP Box, and Excel Range Tools
Using these commands, you can insert various kinds of customized data boxes, in
table form, on your flowsheet. This makes it easy to view current stream, equipment,
temperature/pressure/flow rate, or imported Excel worksheet information in the
CHEMCAD workspace. For a complete discussion of these tools, refer to Chapter 8,
Output and Reports.
Double-click the desired file to return to the main workspace, where the image will
appear highlighted with sizing handles.
As with any other flowsheet object, you can click and drag the image on the
workspace, use the sizing handles to make the image larger or smaller, align the
image with other objects, and even rotate or flip the image.
Figure 3-18: Expanding the drawing tool gallery (left), full gallery showing a tooltip (right)
For other drawing objects, instead of simply clicking and dragging, you must
click multiple times on the workspace to create the line or shape. The following tools
can be used to create multi-sided shapes with many mouse clicks; note that you must
double-click to complete the drawn object and turn these tools off.
● Pipe Line ● Bezier Line ● Closed Bezier
● Path Line ● Polygon
● Spline Line ● Closed Spline Line
To draw these items, you will need to click and drag to define a shape, then click
exactly two points along the shape to complete the drawn object.
● Extend Arc ● Pie ● Chord
After you have drawn a shape on the workspace, the drawing tool is turned off,
and the mouse pointer reverts to a selection arrow. To draw another shape, simply
click the appropriate shape button again.
To make a line or shape exactly like the first one you drew, click the drawn object
to select it, then right-click and use the Copy and Paste commands to place a
duplicate on the flowsheet.
Any drawn object can be easily moved, resized, reshaped, or rotated, using the
green sizing and rotating handles that appear when you select the object. You can
also change the outline or fill appearance on a selected object, by right-clicking and
choosing Line or Fill from the pop-up menu.
Tools for controlling the relative placement of flowsheet items are located in the
Align group. Using these commands, you can align objects in any direction, and
distribute a set of selected items evenly within a given space.
CHEMCAD User Guide 33
The CHEMCAD Interface
To see these tools in action, imagine that you’ve started a flowsheet by placing
three Feed arrows on the workspace, somewhat randomly. You can select them all
and click Align Left to line them up precisely. Then select them again and click
Space Down to distribute them evenly within the vertical space.
Figure 3-20: Feed arrows (left to right) randomly placed, left-aligned, and evenly distributed
Now that the arrows are arranged the way you want, you can select them one
more time and click Group; this will ensure that they remain in the same position
relative to one another if they are ever moved.
Grouped objects will appear highlighted all together if you click on any object in
the group. To separate grouped objects, simply click anywhere on the group to
highlight it and then click Ungroup.
The Rotate and Flip commands can be used to change the orientation of single
objects, grouped objects, or multiple objects selected using [SHIFT]-click.
Flowsheet Quickview
The Flowsheet Quickview feature is turned on by default when you install
CHEMCAD. This handy tool enables you to see a quick data ‘snapshot’ for any
stream or UnitOp on a flowsheet, without even clicking the mouse.
To use this feature, simply hover the mouse pointer over any part of a stream
line or UnitOp symbol. This brings up a pop-up window with relevant data for that
particular stream or UnitOp.
Figure 3-21: Quickview pop-up windows for a distillation column (left) and a product stream
away, toward the top edge of the mouse. To zoom out, roll the wheel down toward
the bottom of your mouse, pulling your fingertip toward your palm. When you
zoom in and out this way, the focal point for the zoom is the location of the mouse
pointer.
You can also click and hold the mouse wheel to pan across the workspace. If
your mouse is not equipped with a scroll wheel, click Auto Pan on the status bar and
then click and drag to pan. To turn off the pan feature, you can either click Auto Pan
again, right-click the mouse, or press [ESC] on the keyboard.
Next to Auto Pan are two buttons used to change the zoom level, or
magnification, of your workspace view. To center the entire flowsheet at the largest
size that will fit in the available workspace Click Zoom to fit. To zoom in on a
specific area of your flowsheet, click Zoom rectangle and then click and drag to
outline the area you want.
To the right of these commands is a slider bar with a numeric percentage display.
You can click and drag the slider to the left to zoom out, or to the right to zoom in.
For small, controlled zoom adjustments, you can click the minus or plus signs on the
ends of the slider bar. When you use the slider bar, the zoom action is centered on
the current center point of the workspace display.
The final zoom tool is a percentage display. Click the number to bring up a Zoom
dialog where you can choose a magnification level or type in a custom zoom
percentage.
Figure 3-23: View tools: Auto Pan, Zoom to Fit, Zoom Rectangle, slider bar, zoom percentage
To lock a specific object in place, click to select that object (a stream, UnitOp, text
box, drawn object) and then click Lock Flowsheet Elements. Now, when you click
the locked object, you’ll see small yellow lock icons instead of the usual green sizing
handles. To unlock the object, simply select it and click Unlock Flowsheet Elements.
Figure 3-25: A heat exchanger as it appears when locked (left), and when unlocked (right)
You can change the lock status of objects individually, or select a block of items
on a flowsheet and change them all with one click of the lock or unlock command.
To lock or unlock the entire flowsheet, simply click into a blank area of the
workspace to ensure that no objects are currently selected, then click the desired
locking command. This approach affects all items currently on the flowsheet; if you
add more items, they are initially unlocked by default.
All the work that you do with CHEMCAD is stored in simulation files. Each discrete
simulation is packaged into a single file that is portable and easy to handle. All the
details of the simulation—from UnitOp specifications to stream composition to
thermodynamics—are included in this file. This chapter describes the various ways
that you can access and manage CHEMCAD simulation files.
Example Files
Especially if you’re new to CHEMCAD, it’s a good idea to open and practice
working with some example files before creating your own simulations. For this
purpose, we’ve created numerous examples of simulations for typical chemical
processes. You can open, view, and edit any example file, and even save a copy in
another location to jump-start a simulation of your own.
The CHEMCAD example files are automatically copied to your computer with a
complete CHEMCAD installation. The examples are organized by process type and
located in the \My Documents\My Simulations\Examples directory.
Note: An alternative method for opening a simulation file is simply to drag and drop
the simulation’s filename from a Windows Explorer window onto the CHEMCAD
workspace.
If you use CHEMCAD on a network and share files with other users, it’s possible
that you could try to open a simulation that is already open for editing by another
user. If you should attempt to open a simulation that is unavailable for editing, a
message box will appear. You can choose to save the simulation with a new name
and/or location, open a read-only copy of the simulation, or cancel the open
operation.
If you should have trouble locating a particular simulation, you can search your
hard drive or network for all files with a .ccsim file extension.
Saving a Simulation
To save all changes in a simulation that you have already named, click Save on the
Quick Access Toolbar, or press [CTRL + S] on the keyboard.
Note: In some cases, such as the built-in CHEMCAD example files, existing files may
be set as read-only to prevent accidental overwriting. You can save a copy of a read-
only file using a different file name and/or file location.
To save a new simulation that you haven’t yet named, click the File tab and then
select Save Simulation As. The Save As dialog box appears, with CHEMCAD
simulation (*.ccsim) as the default file type. Leave the file type as it is, give the file a
unique name, and if necessary navigate to a new file location. Click Save to close the
dialog box and return to the saved simulation.
Note: Any changes you make to a simulation are not saved until you use the Save or
Save As command. This enables you to choose which changes to keep or discard.
Saving and storing all your simulations in the same main directory helps prevent
the lost time and frustration that can result when files are scattered in different
locations. It is recommended that you store your simulations in the My Simulations
directory, which is created automatically within My Documents when you install
CHEMCAD.
E-mailing a Simulation
Sending a simulation file via e-mail is quick and easy. You can either send a
simulation from within the CHEMCAD program or attach the simulation file from
within an e-mail program.
You can now enter your recipient information and add any message text, then
send the message. It’s a good idea to check the attachment information to see the size
of the simulation file, as these files can in some cases be quite large.
Attaching to an E-mail
You can also e-mail any simulation that is stored on a local hard drive or network
without opening CHEMCAD. This comes in handy if you are working on a
computer or other device where you do not have access to a local e-mail program, or
one where CHEMCAD is not currently installed.
To do this, simply create a new message, using your web mail or other e-mail
account. Then use the e-mail program’s command for attaching a file. Navigate to
the directory where the simulation is located, select the appropriate file, and add the
file as an attachment before sending.
Click Save to bring up the Save As dialog box, where you can either keep or
change the file’s name and select a location for the new CHEMCAD NXT copy. Click
Save again to create and open the new file.
To import a simulation file that was created with CHEMCAD 6, you must first
open and save that file using CHEMCAD 7, and then bring the file into CHEMCAD
NXT using the method described here.
The types of simulations you can create using CHEMCAD are many and varied, but
the basic procedure for creating a simulation can be broken down into the following
common steps:
1. Start a new simulation.
2. Specify engineering units for the simulation.
3. Select chemical components for the process.
4. Select K-value and enthalpy options for the process.
5. Draw the flowsheet with appropriate streams and unit operations.
6. Define the feed streams used in the process.
7. Enter specifications for the unit operations.
8. Run the simulation.
9. Review the results of the simulation.
Finding a Component
Because of the large number of components in the CHEMCAD component database,
scrolling up and down the list of available components can be time-consuming. To
find a specific component quickly, use the Search field at the bottom of the Select
Components dialog box.
Type the name of the chemical you want to find in the Search field. With each
letter that you type, CHEMCAD suggests possible matches in the Available
Components list. In the following example, typing the letters wa in the Search field
has highlighted the Water component.
Figure 5-02: Using the Search field to locate the Water component
Note that in some situations, the first result may not be the one you want. For
example, typing ethane in the Search field brings up the Methane component at
first. To see the next match for your text, click Next; continue clicking this button as
needed until you find the desired component.
The Search field accepts both text and numeric entries. By default, CHEMCAD
will search for your entry among all chemical names, chemical formulas, and
CHEMCAD database IDs; if you like, you can also search by CAS RN® number. To
turn any of these search options on or off, click the Options button below the Search
field. This brings up the Search Options dialog box, where you can specify which
data to include in your component searches.
Note: You can add your own custom components to the CHEMCAD component
database. For more details about this feature, see Chapter 9, Customizing CHEMCAD.
Adding a Component
Once you’ve located the component you want in the Available Components list,
simply double-click the component to add it to the Selected Components list for your
simulation.
You can also select multiple components in the Available Components list and
then click the right arrow button, located between the two columns, to add all the
selected components to your simulation. To select multiple components, use
Windows’ standard selection methods of holding down [SHIFT] to select contiguous
items or holding down [CTRL] to select non-contiguous items.
Figure 5-04: Adding multiple components using the right arrow button
If you would like to duplicate the component list from an existing simulation,
click Copy From Another Simulation. In the resulting Open dialog box, navigate to
the desired simulation, select that simulation, and click Open. The Selected
Components list is now populated with the components used in the simulation you
selected; you can add or delete items to customize the list.
Note: When you change the Global K-value Model selection, CHEMCAD
may automatically update the Global Enthalpy Model setting as
appropriate. If this happens, you will see a message on the K-value Models
tab. You can change the selected enthalpy model by making a new selection
in the Enthalpy Models tab.
4. Click the Enthalpy Models tab, select the most appropriate model in the
Global Enthalpy Model field, and make any other changes to the options on
this tab as needed for your process.
5. Click the Transport Properties tab and verify that the settings there are
appropriate for this simulation. Change any settings as needed and then click
OK to close the Thermodynamic Settings dialog box.
Adding UnitOps
Start by adding UnitOp symbols for the equipment that will be part of your
simulation. The tools for adding UnitOps to a flowsheet are located in the Palette
pane, which by default displays on the right margin of the CHEMCAD window.
This pane offers specialized palettes for UnitOp categories such as Heat
Exchangers and Reactors, but the default palette view is All UnitOps, which displays
all the available UnitOp icons at once.
Note: If you do not at first see the Palette pane, it may have been turned off. To
restore this pane, click the View tab, then click Palette in the Show group. If the
pane is turned on but you only see the word Palette sideways in the upper right
corner of the screen, the pane is unpinned; see Chapter 3, The CHEMCAD
Interface, for information about pinning and unpinning panes.
2. Click the symbol and drag it onto the workspace where you want to place the
UnitOp. When you release the mouse button, the UnitOp symbol appears
where you clicked.
Note: Items that are already in place on the flowsheet will not be affected when
you select a new default symbol for a UnitOp.
To view the symbols available for a given UnitOp, right-click the current symbol
on the palette. A subpalette will pop up, displaying all available symbols.
From a subpalette, you can drag any symbol onto the flowsheet, just like the
symbols on the main palette. When you do this, the selected symbol appears on the
flowsheet and the subpalette automatically closes.
To change the default symbol for a UnitOp, first right-click to open the
subpalette, then hold down the [CTRL] key and click the symbol you want to use.
After you do this, the symbol you selected appears on the main palette. You can
change the default icon for a UnitOp as often as you like.
UnitOp IDs
When you place UnitOps on a flowsheet, CHEMCAD assigns each one an ID
number that is unique within the simulation. The UnitOp number is a vital identifier
for the unit, as it is used in various reports and charts related to the simulation.
The UnitOp ID is displayed in an oval, easily distinguishable from the
rectangular boxes used to display Stream IDs.
The default position of a UnitOp ID is just above and to the left of the unit’s
flowsheet symbol. If you subsequently move the UnitOp symbol, its ID remains in
the same relative position.
In some situations, you may want to move a UnitOp ID from its default location.
To do this, click the UnitOp to highlight it, then move your mouse cursor over the
UnitOp ID oval. When you see the cursor change to a curved hand shape, click and
drag the ID oval to the desired location.
Figure 5-07: The hand cursor for moving a UnitOp ID (left), an ID being moved to the opposite
side of the UnitOp symbol, and the ID oval in its new location
UnitOp ID Ranges
When you place UnitOps on a flowsheet, CHEMCAD assigns each one a UnitOp ID
number that is unique within the simulation. The UnitOp ID number is an important
identifier for the unit, as it is used in various reports and charts related to the
simulation. By default, your UnitOps will be numbered, starting at 1, in the order in
which you create them; all types of equipment share the same pool of ID numbers.
If you want to group your UnitOps numerically by equipment type, you can use
the Starting IDs feature to accomplish this.
Click the Specification tab, then in the Simulation group, click Starting IDs.
This brings up the Stream and UnitOp Starting IDs dialog box. Here you will see
each type of UnitOp available in CHEMCAD, each with a default Starting ID setting
of 1. This means that any new UnitOp will be assigned an ID from the same number
pool—the next number (1 or greater) that has not yet been used in this simulation.
To set up separate ranges of numbers for different equipment types, you can edit
the values in the Starting ID column. For example, you could set the Heat Exchanger
value to 200, the Pump value to 300, the Pipe value to 400, and so on, using any
starting values that are meaningful to you. Any UnitOp type you don’t assign a
starting value will pull ID numbers from the main pool starting with 1, skipping any
numbers that are already assigned.
Click OK to put your selected starting IDs into effect.
UnitOp Names
In addition to the assigned ID, you can give a UnitOp a name, using up to 11
alphanumeric characters. This name appears in the UnitOps area of the CHEMCAD
Explorer pane, on certain reports, and optionally on the flowsheet with the UnitOp
ID.
To add a UnitOp name, right-click the UnitOp on the flowsheet and select Edit
Name; type the name in the resulting dialog box and click OK.
By default, a newly added UnitOp name will appear beneath the number in the
UnitOp ID box. To hide a single UnitOp’s name, right-click the UnitOp and clear the
check mark next to Show Name; simply check this menu item again to make the
UnitOp name visible.
To view or hide all UnitOp names on the flowsheet at once, click the View tab,
then in the Flowsheet group, either check or clear the Show UnitOp Names box.
Note: Once a feed or product arrow is connected to a stream, you can double-
click the arrow to open the Edit Streams dialog for the associated stream.
3. Click and drag toward the desired inlet on the downstream UnitOp. When
you see the cursor change to an anchor shape, and the inlet port outlined in
red, release the mouse button.
4. The stream will appear between the objects you have connected.
Note: You can also click and release at the outlet port, move the mouse
pointer wherever you like, and then click and release again when you reach
the desired inlet port. There is no need to hold the mouse button down the
entire time.
Rerouting a Stream
Even after you’ve completed your flowsheet and added detailed information about
your streams, you can still reroute a stream if needed. There are two ways to do this.
The first method is to move the existing stream around using its sizing handles.
When you click on a stream to select it, the stream line displays in green, and small
green sizing handles appear. Each stream turn will have a sizing box, as well as each
stream segment. You can click and drag any of these handles to move the adjacent
stream segment(s) to a new location.
If you click a corner sizing handle, you can move the two adjacent stream
segments in any direction; this often affects the position of other stream segments as
well. If you click a sizing handle in the middle of a stream segment, then you can
only move the segment left and right (for a vertical segment) or up and down (for a
horizontal segment).
The second method for rerouting a stream is to re-draw it entirely. To do this,
click the stream to select it, then right-click and select Reroute stream. The old
stream disappears, replaced by the beginning of a new stream originating at the
same outlet.
You can now click to create 90° turns, the same way you would with a new
stream, to route the stream exactly where you want it. After a stream is rerouted, it
retains all of the stream detail that you had previously entered.
Stream IDs
When you draw streams on your flowsheet, CHEMCAD assigns each one a stream
ID number that is unique within the simulation. The stream number is an important
identifier for the stream, as it is used in various reports and charts related to the
simulation.
The stream ID is displayed in a rectangular box, easily distinguishable from the
ovals used to display UnitOp IDs.
When you draw a stream, the ID box is positioned on the longest stream
segment. If you subsequently move the flowsheet objects that contain the stream’s
end points, or otherwise change the path of the stream, the stream ID box will
change its position accordingly.
In some situations, you may want to move a stream ID box from its default
location. To do this, click the stream to highlight it, then move your mouse cursor
over the stream ID box. When you see the cursor change to a curved hand shape,
click and drag the ID box to the desired location.
Figure 5-09: The hand cursor for moving a stream ID box (left) and a stream ID box being moved
If you have manually placed a stream ID box, you might later want to restore it
to its default location on the stream. To do this, simply right-click the stream or the
ID box and select Reset ID Position. This returns the stream ID box to its automatic
placement on whichever stream segment is currently the longest.
Stream ID Ranges
By default, your streams will be numbered, starting at 1, in the order in which you
create them. If you want to create a series of streams with a separate range of ID
numbers from the rest of your simulation, you can use the Starting IDs feature to
accomplish this.
Click the Specification tab, then in the Simulation group, click Starting IDs.
This brings up the Stream and UnitOp Starting IDs dialog box. Scroll down to the
Stream option and click the right column. Enter the number that will be the start of
your separate stream ID pool and then click OK. If you later need to draw more
streams with ID numbers in the normal range, you can return to this dialog box and
reload the default setting.
For example, to draw a series of utility streams with ID numbers starting at 300,
you would set the stream starting ID option to 300 and draw the streams in question.
Those streams would be numbered 300, 301, 302, and so forth. After drawing all
your utility streams, you would then set the Stream ID option back to 1, so that the
next new stream in the main flowsheet would be assigned the next available stream
ID from the regular pool of numbers. You can reset the stream option number as
many times as needed while you create and edit your simulation.
Stream Names
In addition to the assigned stream ID, you can give a stream a name, using up to 11
alphanumeric characters. This name appears in the Edit Stream dialog, in the
Streams area of the CHEMCAD Explorer pane, on certain reports, and optionally on
the flowsheet with the stream ID.
To add a stream name, you can open the Edit Streams dialog and type in the
Stream Name field. Another way to add a name is to right-click the stream and
select Edit Name; type the name in the resulting dialog box and click OK.
By default, a newly added stream name will appear beneath the number in the
stream ID box. To hide a single stream’s name, right-click the stream and clear the
check mark next to Show Name; simply click this menu item again to make the
stream name visible.
To view or hide all stream names on the flowsheet at once, click the View tab,
then in the Flowsheet group, either check or clear the Show Stream Names box.
Stream Intersections
When streams cross on a flowsheet, a visual indicator can be helpful to show that the
streams do not interact with one another. You can set up a default size and shape to
show one stream “jumping” over another wherever two streams meet. By default, a
stream jump displays as a semicircle.
CHEMCAD offers several other options for stream intersections, including no
jump indicator and a dash to break one stream line as it crosses. The figure below
shows all of the available stream intersection options.
CHEMCAD User Guide 59
Building and Using a Basic Simulation
Figure 5-10: Stream intersection options (from left: None, Dash, Triangle, Trapezoid, Square,
and the default setting, Circle)
To select a stream intersection option for the current simulation, click the Drawing
tab, then in the Workspace group, click Stream Styles. In the Stream Styles dialog,
drop down the Style list under Intersections, and select an option. When you click
OK, any stream intersections already on your flowsheet will change to the new style;
any new intersections that occur will also use that style. This style will continue to be
used for new intersections, even after this simulation has been closed and re-opened.
To change the global style for stream intersections—that is, to set the default for
all future simulations created in your CHEMCAD installation—you can change the
setting in a different place. Click the File tab, then Preferences. In the Preferences
dialog, click Stream Styles in the left column. This brings up the same list of stream
intersection options, but when you select one and click OK, the chosen style will
become the global default for this CHEMCAD installation.
Note that you can also change the size of the stream jumps in both the local and
global settings for stream intersections. The default size is 48, which is well
proportioned for use with standard UnitOp sizes.
Defining Streams
At this point, the streams that you have drawn on your flowsheet are still just lines
with no data behind them. The next step is to edit these streams as needed,
populating them with composition data and other properties.
In most situations, the streams you’ll need to define will be the feed streams in
your process. Other types of streams, such as recycle cut streams, may also require
definition.
You can edit a single feed stream using any of these methods:
• Double-click the stream.
• Right-click the stream line and select Edit Stream.
• On the Home tab, in the Specification group, click Edit Streams. Enter the
stream number you want to edit and then click OK.
• On the Explorer’s Simulation tab, expand Flowsheet and then Streams,
right-click the stream in question, and select Edit Stream. (This is a useful
approach for especially large and complex flowsheets.)
To edit multiple streams at once, you can use the following methods:
• Hold down [SHIFT] and click to select multiple streams on the flowsheet, then
right-click and select Edit Stream.
• Click Edit Streams in the Home tab’s Specification group, then either type
the stream numbers into the Select Streams dialog box or click the streams on
the flowsheet to add them to the list. Click OK when finished.
• To edit all the feed streams in the flowsheet at once, click the Edit Streams
drop-down (Home tab, Specification group) and select Edit Feed Streams.
Similarly, to edit all the cut streams in the flowsheet, select Edit Cut Streams
from the same drop-down.
The Edit Streams dialog box displays with either a single column of data (for one
stream) or a column for each stream that you have selected. Use this dialog box to
specify properties for each feed stream listed.
Thermodynamic Properties
You must specify exactly two of the following three variables:
• Temperature
• Pressure
• Vapor fraction
CHEMCAD will calculate the third variable and enthalpy, based on the two
variables you specify and the thermodynamic method you’ve selected, once the
stream composition data has been entered.
Note: In the Edit Streams dialog box, the user-specified values for feed streams will
display in green, differentiating them from calculated values.
Stream Composition
To define the stream composition, you’ll need to specify a composition unit and the
amount of each component that is present in the stream.
Select a unit from the Comp unit drop-down list, and then based on that
selection, populate the field for each component with the appropriate amount,
percentage, or fraction.
For stream compositions expressed as a percentage or fraction, you can enter
values that do not total 100%. In this case, CHEMCAD will normalize the
composition to fractional values that total 1. To preview the normalized values that
CHEMCAD assigns to the components, click Flash.
• Total flow
• Total flow unit
If you enter composition amounts using quantitative flow units, CHEMCAD
calculates the total flow rate for you.
Figure 5-11: Two UnitOps that require very different amounts of input
The detailed information about the specifications for each type of UnitOp is
contained in the CHEMCAD Help system, which you can access from any
CHEMCAD screen by pressing the [F1] key.
These specification screens do, however, have certain rules in common:
• Items with green text labels are required entries.
• All other entries are optional.
• Clicking OK saves your specification changes; clicking Cancel discards them.
After you click OK, CHEMCAD checks your data for internal consistency and
then returns errors or warnings as warranted. These items display in the Messages
pane in the CHEMCAD window.
Now that you’ve drawn the flowsheet and added detail to the streams and UnitOps
that make up the flowsheet, you can run the simulation. To do this, simply click Run
All in the Home tab’s Run group.
When you run a simulation, CHEMCAD calculates material and energy balances
throughout the entire flowsheet and returns any errors or warnings discovered in
the flowsheet. If the run completes successfully, a Run finished message appears at
the far left of the status bar, at the very bottom of the CHEMCAD window.
If the flowsheet run has converged, the message Flowsheet calculation has
converged will appear in a pop-up message window, as well as in the Messages pane.
The word Converged will also appear near the center of the status bar; this message
will continue to display until you make changes to the flowsheet or the simulation
models that could affect convergence, and it will reappear after each successfully
converged run.
For preliminary checks of individual UnitOps or groups of UnitOps, you can
click Run Selected instead of Run All; either highlight the relevant UnitOps on the
flowsheet before invoking this command or select them afterward in the Select
UnitOps dialog box. You can also right-click any UnitOp on the flowsheet and select
Run This UnitOp.
Note: CHEMCAD reports, plotting, and chart printing are covered in detail in
Chapter 8, Output and Reports.
Simulations created in CHEMCAD vary greatly in detail, from vague and conceptual
to extremely specific and realistic. Depending on the demands of your process and
what you’re trying to achieve with your simulation, you may work with what we
call low-fidelity modeling, high-fidelity modeling, or both.
This chapter addresses CHEMCAD’s capacity for high-fidelity modeling and
how to achieve a high level of realism with your UnitOps.
Figure 6-01: Commands for sizing various UnitOps, accessed via the Sizing tab
Piping
You can use either low- or high-fidelity modeling for piping in your simulation.
Pipeline sizing is done based on the composition of a selected stream.
Low-fidelity
For low-fidelity modeling of piping, you are required to specify pipe diameter and
length in most modes; design modes that calculate diameter are the obvious
exception to this. The pressure drop through the pipe is calculated based on
diameter, length, and flow rate through the pipe.
Sizing
To perform sizing calculations, first click the Sizing tab. In the Flow group, click
Piping, and then select the relevant stream or streams. In the Pipe Sizing dialog box,
select a sizing option and click OK for line sizing results. You can use these results,
such as suggested pipe thickness and diameter, to specify geometry for a Pipe
UnitOp, or simply review them for the information you need.
Note: You can also click to select the relevant stream on the flowsheet (hold down
[SHIFT] to select multiple streams), then right-click and select Line Sizing to access
the Pipe Sizing dialog box.
Figure 6-02: Line sizing results from the Pipe Sizing dialog box
High-fidelity
In high-fidelity piping models, Pipe UnitOps interact with Node UnitOps to balance
pressure and flow rates hydraulically among connected pieces of flow-based
equipment. Nodes must be placed on both sides of all Pipe UnitOps to be included
in hydraulic balance; pressure and flow constraints are set at the nodes, not in the
pipes.
A high-fidelity piping model can show changes in flow rate based on back
pressure where two pipes mix, whereas a low-fidelity model would simply assign
the lower of two specified pressures to the outlet without consideration for back
pressure.
Low-fidelity
For these equipment types, CHEMCAD calculates power usage and thermal effects
on the fluid, based on specified output pressure or pressure increase. Other
parameters, such as efficiency, are optional but do affect results.
High-fidelity
To produce a high-fidelity model for these equipment types, you must select the
operation mode in which you specify performance curves—that is, pressure change
as a function of volumetric flow rate. This performance information is generally
available from the equipment vendor. Based on the volumetric flow entering the
UnitOp, CHEMCAD calculates outlet pressure.
As with piping, high-fidelity modeling for pumps, compressors, and expanders
can be used with nodes as part of a hydraulic flow balanced network.
Low-fidelity
With low-fidelity modeling of a vessel or tank, a stream enters the Flash UnitOp and
separates into vapor and liquid; CHEMCAD does not consider hold-up or liquid
level in the tank. If you want to take a steady-state snapshot of the vessel, you can
manually adjust the flow rate and/or thermal conditions to make volumetric flow
rates match the volume of the vessel.
Note: The Batch Tank UnitOp is specifically intended for use with the Batch
Distillation Column UnitOp. It does not represent a standard storage tank for
general purposes.
Sizing
To calculate sizing for a vessel, first select a Flash UnitOp, then click the Sizing tab.
In the Vessel group, click either LV Vessel (liquid-vapor vessel) or LLV Vessel
(liquid-liquid-vapor vessel), depending on your needs. In the resulting dialog boxes,
enter the appropriate values for your vessel and click OK.
The results that CHEMCAD returns include basic vessel geometry such as height
and diameter.
You can also perform vessel sizing on a converged distillation column to
calculate geometry for a reflux drum or similar piece of equipment.
High-fidelity
You can perform high-fidelity modeling only on vessel reactors and dynamic
vessels, and only with a CC-DYNAMICS license (for dynamic vessels, a CC-SAFETY
NET license will suffice). If you specify the geometry of your vessel and use
CHEMCAD’s dynamics mode, you can study what happens in the vessel over time
as material is added or withdrawn.
Unlike simple flash vessels, vessel reactors and dynamic vessels do consider
hold-up, liquid level, and variable pressure over time.
Valves
Valve modeling in CHEMCAD can be either low-fidelity or high-fidelity. You can
size a control valve based on any flowsheet stream.
Low-fidelity
The Valve UnitOp is used for low-fidelity modeling of a valve. For this type of
UnitOp, you specify outlet pressure or pressure decrease through the valve.
Sizing
To size a control valve, first click the Sizing tab. In the Flow group, click Control
Valve, then select a stream. In the Control Valve Sizing dialog box, specify the outlet
pressure for the theoretical valve, and enter other specifications as appropriate.
When you click OK, CHEMCAD returns information such as capacity coefficient
(Cv) and valve size.
Note: You can also click to select the relevant stream on the flowsheet, then right-
click and select Control Valve Sizing to access the Control Valve Sizing dialog box.
High-fidelity
The CVAL UnitOp is used for high-fidelity valve modeling. Decide which values
you will provide and which values CHEMCAD will calculate, and select the
appropriate operating mode in the Control Valve dialog box. Provide the valve’s Cv
value, and any other specifications as needed.
Control valves can be used with nodes as part of a hydraulic flow balanced
network.
Columns
Columns in CHEMCAD can be modeled as either low-fidelity or high-fidelity. You
can perform sizing on any converged column.
Low-fidelity
For low-fidelity modeling of columns, use the Tower, Tower Plus, or SCDS UnitOps.
Specify ideal stages and the conditions at the reboiler and condenser, as applicable.
A low-fidelity column model does not consider mass transfer effects or column
internals.
Different column specifications can provide more realism without taking
geometry into account. Specifying top purity is a very low-fidelity model, while
specifying reflux ratio or condenser duty can bring your results closer to reality.
Sizing
After running your simulation, first select the UnitOp representing the distillation
column, then click the Sizing tab. In the Distillation group, click either Trays or
Packing, based on the type of column.
The resulting dialog boxes prompt you to enter information about your trays or
packing and the calculation methods you want to use for column sizing. You will
generally need to enter some geometry and hydraulic parameters to complete
column sizing.
Figure 6-05: Specifying high-level tray data for distillation column sizing
Based on flowsheet values and your sizing input, CHEMCAD returns column
geometry information such as height and diameter. It also provides hydraulic
performance information such as predicted amount of flooding.
High-fidelity
To perform high-fidelity modeling of a distillation column in steady state, use the
SCDS UnitOp and select either of the mass-transfer simulation models for the
column.
You will need to specify geometry for the column and choose a calculation
method for the selected mass-transfer model. CHEMCAD calculates column
performance based on your packing or tray specifications.
For columns, mass transfer-based modeling performs rigorous non-equilibrium
mixing of vapor and liquid, whereas low-fidelity modeling assumes ideal mixing.
To perform high-fidelity modeling of a distillation column in dynamics, specify
the geometry of the column and details about the control system. This dynamic
distillation can consider column hold-up and the effect of variables changing over
time.
Note: The Shortcut Column UnitOp is not a rigorous calculation model. Unless your
system satisfies the constant molar underflow assumption, you should consider
using a different type of distillation column.
Heat Exchangers
When specifying a heat exchanger in a simulation, you can use either low- or high-
fidelity modeling as well as sizing, depending on the type of heat exchanger
involved.
Low-fidelity
When creating a simulation, you can use a low-fidelity approach by simply
specifying the thermal conditions coming out of the exchanger. Specifying heat duty
instead of merely an outlet temperature brings your results closer to reality, but this
approach still doesn’t consider geometry.
Sizing
You can use the CC-THERM module for rigorous calculation of heat transfer
coefficient (U) based on heat exchanger geometry. In rating mode, CC-THERM
determines whether the user-specified heat exchanger is capable of the flowsheet
heat exchanger performance. In design mode, CC-THERM calculates an exchanger
design that is capable of the flowsheet performance.
High-fidelity
For some exchanger categories—specifically shell-and-tube and double-pipe—you
can use the rigorous CC-THERM model to calculate heat exchanger performance.
The flowsheet results are based on rigorously calculated U value and the specified
exchanger geometry. You can also determine approximate fouling of a unit if actual
outlet temperatures are known.
Relief Devices
For relief devices, sizing is not necessarily distinct from low-fidelity modeling. To
model dynamic relief of a vessel, you can instead use high-fidelity modeling.
Low-fidelity
To model a steady-state snapshot of a relief device, first click the Sizing tab. In the
Safety group, click Relief Device to bring up the DIERS for Relief Device Sizing
dialog. Here you can specify a rating or design mode and select the appropriate
options for your relief scenario. When you click OK, CHEMCAD returns a relief
device calculation summary.
High-fidelity
If you select the Rigorous integral analysis design method when sizing a relief device,
you will obtain a results based upon the changing latent heat of the liquid as it
changes over time.
Figure 6-08: Selecting the rigorous integral analysis method for relief device design
You can also perform high-fidelity relief device modeling for the Vessel Reactor
and Dynamic Vessel UnitOps. You can specify the relief device nozzle area, as well
as other specifications for your relief scenario. This enables you to study the dynamic
relief of the vessel.
While steady-state modeling can provide all the information you need for many
purposes, it’s often informative to look closely at the changes over time that affect
your streams and equipment. CHEMCAD’s CC-DYNAMICS module makes it
possible to simulate a process over time.
Licensing Considerations
To use the functionality described in this chapter, you must have a valid license for
the CC-DYNAMICS module of CHEMCAD. To view or change the disposition of
your CC-DYNAMICS product license, see the CHEMCAD License Monitor screen
(File tab, then Licensing).
If you don’t currently have access to the dynamics features and want to add CC-
DYNAMICS to your installation of CHEMCAD, contact the person within your
organization who handles software licensing, or if appropriate, contact Chemstations
or a CHEMCAD distributor directly. For a complete list of Chemstations contacts
and CHEMCAD distributors for all parts of the globe, see our website
(www.chemstations.com).
Switching to Dynamics
To switch to dynamics, first open the simulation. On the Home tab, simply click the
word Dynamic in the Run group.
After you do this, you’ll notice that a few things have changed on the CHEMCAD
screen:
• The status bar at the bottom of the main CHEMCAD window changes. A few
inches from the left edge of the screen, instead of the words Steady State,
you’ll now see DTime and a time counter displaying the number of minutes
your simulation has run. Before you run the simulation, the DTime setting
displays 0:00 min.
• The steady-state commands on the Home tab’s Run group are now
unavailable, and the dynamics commands are activated.
Figure 7-02: The General tab on the Dynamic Run Time Schedule dialog box
2. On the General tab, set the number of operation steps you plan to use, or
leave the default setting of 1. The maximum number of steps that you can
specify is 10.
Note: When you initially set up dynamics for a simulation, the Current time display
field on this tab will be empty. After the simulation has run, this field displays the
total time of a completed run, or the current time of an interrupted run.
3. Now click the Step 1 tab and specify the parameters for this portion of the
dynamic run. Enter the total time for this dynamic step in the Run time field,
and the interval in minutes in the Step size field.
Figure 7-03: The Step 1 tab on the Dynamic Run Time Schedule dialog box
4. If you have other steps to specify, click each tab in turn and enter the Run
time and Step size information.
5. When you have specified all steps, click OK to return to the main
CHEMCAD workspace.
The Dynamic Run Time Schedule dialog box also allows for conditions other
than time to determine the duration of a dynamic operation step. If you select
Stream or Equipment instead of the default Time option, you can specify a stream
or UnitOp parameter that will trigger the end of this step, if that parameter is
reached before the step’s run time is up.
3. When you have selected all the streams you want to record, click OK to
return to the main workspace.
4. Now click the Set Run Time drop-down again, and this time select Record
UnitOps. In the Record UnitOps dialog box, select UnitOps in the same way
that you selected streams in step 2.
5. Click OK to return to the main CHEMCAD workspace.
Note: In both the Record Streams and Record UnitOps dialog boxes, you can use
the Chart check boxes to include selected items in a real-time chart. Selecting
items for runtime plotting leads to another dialog box (either Dynamic Stream
Chart Options or Dynamic Equipment Chart Options), where you can select
chart specifics for each stream or UnitOp. It is recommended that you use
runtime plotting in moderation, as too many streams and UnitOps can become
visually confusing and slow down calculations considerably.
6. Before proceeding, click Save in the Quick Access Toolbar to ensure that the
current settings are used as the simulation’s initial state.
To return the simulation to its initial state—also known as time zero—simply click
Reset to Initial State.
Note: An advanced feature to allow specification editing at any time is available, but
should be used with extreme caution to avoid confusion and unintended results.
This feature is controlled by a check box on the Convergence Parameters dialog box.
In dynamics mode, you have three options for running a simulation: run from
the simulation’s initial state, run from the simulation’s current state, or manually
advance the simulation one interval at a time.
Note: At any point during a dynamic run, you can press the [ESC] key on your
keyboard to stop the run after the current calculation. When you do this, you will see
a Program interrupted message. Click OK to close the message box, and then either
inspect your run results or select a run command to continue.
Figure 7-05: Selecting the command to run one interval in a dynamic simulation
Note: For the Stream History and UnitOp History charts, be sure to record the
streams and UnitOps that you want to study. You can only request these charts for
recorded streams or UnitOps.
Note: For the Stream History and UnitOp History reports, be sure to record the
streams and UnitOps that you want to study. You can only request these reports for
recorded streams or UnitOps.
When you make a valid selection, CHEMCAD brings up a dialog box where you
can specify what to include in the requested chart or report. (If you choose a
selection that is not valid—for example, a chart type that is not compatible with your
current thermodynamic settings—you will see a message box explaining the error.)
After you specify the parameters for the chart or report, the results will display.
Charts and reports always display in their own tabs on the main CHEMCAD
workspace. Whenever a chart or report tab is selected, the ribbon displays
commands specific to charts or reports, respectively.
Note that there are also large icons above both the Charts and Reports
commands. When you first launch CHEMCAD, the icons displayed match the first
items in the respective galleries. When you select a different chart or report from a
gallery, you will see that item’s icon display on the command ribbon. If the next
chart or report you want to generate next is the same as your last selection, you can
simply click the icon to choose that item without opening the gallery. This can save
time whenever you find yourself generating the same chart or report repeatedly.
Figure 8-02: Icons above the Charts and Reports drop-down commands: defaults (left) and
examples of “last used” items (right)
Thermodynamic
CHEMCAD offers several charts that relate specifically to a simulation’s selected
components and thermodynamic options. To access any of these items, click Charts
to view the gallery, then select the appropriate item under the Thermodynamic
heading.
TPXY
This selection generates vapor-liquid equilibrium curves between any two
components, with an optional third component. You can include TPXY, TXY, activity
coefficient, and fugacity coefficient curves.
Binary LLE
This selection generates liquid-liquid equilibrium curves between any two
components.
Binodal Chart
This selection generates a ternary phase diagram showing the distribution of three
selected components in two liquid phases, including tie lines and plait point.
Residue Curves
This selection generates and plots a graphical display of distillation zones,
azeotropes, and residue curves associated with a user-specified ternary mixture.
Binodal/Residue Curves
This selection creates a plot that combines the curves from a binodal plot and a
residue curve plot. This is useful when working with heterogeneous azeotropic
distillation.
Binary SLE
This selection displays solid-liquid equilibrium curves for binary mixtures.
Stream
CHEMCAD offers several charts that display data for selected streams on a
flowsheet. To access any of these items, click Charts to view the gallery, then select
the appropriate item under the Stream heading.
For any of these charts, you can choose the streams to include by typing in their
ID numbers in the Select Streams dialog; click the streams on the flowsheet to add
them to the stream ID list; or use All Streams, Feed Streams, Product Streams, or
Cut Streams to add groups of streams with a single click.
Stream Properties
This selection plots one selected stream property for any or all streams on the
flowsheet.
Phase Envelopes
This selection plots a phase envelope for a selected stream, highlighting the critical
point of the mixture. This chart can include plots at vapor fractions other than 0
(bubble point curve) and 1 (dew point curve).
Petroleum Assay
This selection displays a chart of one or more distillation curves for a stream.
UnitOp
CHEMCAD offers several charts that display data for a single UnitOp. To access any
of these items, click Charts to view the gallery, then select the appropriate item
under the UnitOp heading.
Column Profiles
This selection plots compositions, temperature, and flow profiles for distillation
columns.
Heat Curves
This selection plots heating and cooling curves for a selected heat exchanger.
Composite Curves
This selection plots composite heat curves for the entire flowsheet, as well as
optional heat curves for individual UnitOps.
Pipe Profile
This selection plots fluid properties for pipe UnitOps along the axial length of the
pipe. This chart requires that the pipe contain multiple segments.
Controller Convergence
For controllers that have not converged, this chart enables you to diagnose the
controller behavior that is preventing convergence. The chart shows how the
controller error function changes with iteration.
Dynamic
CHEMCAD offers a series of charts for use with dynamic, or non-steady-state,
operations. (For more on dynamic process simulation, see Chapter 7, Building and
Using a Dynamic Simulation).
To access any of these charts, click the Charts gallery, then select the appropriate
item under the Dynamic heading.
Stream History
This chart displays stream data recorded over the course of a dynamic run. Before
requesting this chart, you must first use the Record Streams command to select
streams to include, and then run the dynamic simulation.
UnitOp History
This chart displays UnitOp data recorded over the course of a dynamic run. Before
requesting this chart, you must first use the Record UnitOps command to select
UnitOps to include, and then run the dynamic simulation.
Column History
This chart displays selected data for a single dynamic run of a column. Note that in
the Dynamic Column Chart Options dialog, if you choose to plot a variable for a
specific stage, that stage must have been recorded during the dynamic run as part of
the column’s specifications.
Vessel Reactor
This chart displays selected data over time for a single dynamic run of a Vessel
Reactor UnitOp. In the Vessel Reactor Chart Options dialog, you can select various
equipment parameters to chart, and choose whether to include reactor composition
over time.
Dynamic Vessel
This chart displays selected data over time for a single dynamic run of a Dynamic
Vessel UnitOp. Composition over time can be displayed or excluded, and you can
single out a specific phase to appear on the chart.
Batch Column
This chart displays selected data over time for a single run of a Batch Distillation
UnitOp. In the Batch Column Chart Options dialog, you can choose to plot all
operation steps or specify a single step to include.
User
If you have customized CHEMCAD using VBA, C++, or other programming
languages, you can save chart data into a text file and use this feature to display that
data as a curve.
To access this feature, click Charts and then select User-specified at the bottom
of the gallery. This brings up a message box that provides instructions on how to
format the text file. Click OK to continue to an Open dialog box, where you can
select the text file you want to use. When you click Open, the curve is plotted and
displayed.
Whenever you are viewing a chart, the top of the CHEMCAD window displays
the Chart tab, beneath the title Charting Tools. On this tab, you will find specialized
commands that control the appearance of the current chart’s data and labels.
The Chart tab commands are described below.
Edit Group
Close All Charts
This command closes the current chart, along with every other chart that is currently
open. To close only the current chart, simply click the x on the chart’s tab at the
bottom of the workspace.
Save
This command enables you to save a chart within the simulation. Saved charts are
listed in the Explorer pane under Saved Charts, where you can re-open them for
later reference. This command is also used to save any changes you may have made
to a re-opened chart.
Save As
This command is much like Save, except that it brings up a Save As dialog that
requires you to provide a name for the chart that you are saving. You can also use it
to make a copy of a re-opened chart under a different name, so that you can change
the new copy’s settings or labels while keeping the original copy.
Export Chart
You can use this command to export the current chart data, either as an Excel .csv
file or as a semicolon-delimited table.
User Series
The User Series feature enables you to add a data point or series of points to an open
chart in a CHEMCAD simulation. This information appears alongside the chart’s
calculated results. This feature is discussed in greater detail later in this chapter.
Type
This setting determines whether the chart displays both data markers and
connecting lines (the default setting), only lines, or only markers.
Legend
This setting determines the location of the chart’s legend. The default location is to
the right of the chart; you can also choose to display the legend above or below the
chart, to the left of the chart, or not at all.
Fixed Axis
By default, CHEMCAD charts place the X and Y axis lines at the edges of the display
area. In cases where the range of data spans the positive and negative number space,
you may prefer to see the lines drawn at X = 0 and Y = 0 for easier reference. Clear
this check box to show the labeled axis lines intersecting at the point of origin. Note
that this option is not available for use with ternary charts.
Spline
Check this box to produce a display where data points are connected by smooth,
curved lines instead of straight lines.
Label
This field displays the default label for the relevant axis. To change the axis label,
type new text here.
Formatting
Use this drop-down set of options to customize the numbers and lines that make up
the relevant axis. The Numerical Display commands (Format Type, Format Digits)
control the way grid numbers display on the axis, and the Axis and Grid commands
(Axis Color, Grid Fade) determine the color and visibility of the axis’ grid lines.
Log Scale
Check this box to switch from linear to logarithmic scale for the relevant axis.
Assigned Series
This control is available for all but the X axis. Click the drop-down control to view
the available data series. Check or clear the box next to a series name to turn that
series on or off for the relevant axis.
Window Group
These commands offer a quick way to place all open tabs in view at the same time.
Click Tile Horizontally to arrange items across the width of the workspace, or Tile
Vertically to arrange them next to one another.
When you add a user series, it becomes available for use in all current chart tabs,
as well as in all future charts that you generate for the current simulation.
First type a descriptive name in the Series Name field, then enter the desired
data points in the X and Y columns. (Note that you can paste numerical values here
from the Windows Clipboard; simply right-click in the cell where you want the first
copied value to appear and select Paste. See the full description below for more
detail.)
To save the new user series and return to your chart, click OK.
select Paste. The values you copied from another source will populate the cells of the
dialog.
Note that if you copy a block of cells that consists of more than two columns,
only the leftmost two columns will be pasted into the Add User Series dialog.
Note: To remove a point of interest that you have added to a ternary chart, first
delete the applicable user series and then close the chart tab. When you return to the
same chart (Home tab, Results group, then click the ternary chart icon above the
Charts drop-down), the point of interest will no longer be displayed.
The available reports are listed and described below, according to the group
headings displayed in the Reports gallery.
Stream
You can run stream property reports for any grouping of streams from your
simulation, as well as specialized stream-based reports for particle size distribution
and petroleum assays.
Select
Choose the streams you want to include in the Select Streams dialog box, either by
typing in the stream numbers (one per line) or by clicking on streams in the
flowsheet. Click OK to close the dialog box and display the report.
All
This report displays stream property data for every stream on the flowsheet. No
further input is required after you click All in the Reports gallery.
Feed
This report displays stream property data only for streams issuing from a Feed icon
on the flowsheet. No further input is required after you click Feed in the Reports
gallery.
Product
This report displays stream property data only for streams terminating in a Product
icon on the flowsheet. No further input is required after you click Product in the
Reports gallery.
UnitOp
This report displays property data for all inlet and outlet streams connected to a
specified UnitOp on the flowsheet. If no UnitOp icon is selected when you run the
report, you’ll see the Select UnitOps dialog box; type the UnitOp ID or click the
UnitOp on the flowsheet and then click OK to display the data. If you select a
UnitOp icon before running the report, the data will display without further input.
Note: You can also generate a stream report from the flowsheet. To do this, click the
applicable stream (or [SHIFT]-click to select multiple streams), then right-click to
bring up the stream menu. Select Stream Reports and then choose a property set
from the menu flyout to generate the stream report.
Petroleum Assay
For a text report on pseudocomponent curves (also known as distillation curves),
select Petroleum Assay from the Reports gallery. Select one or more streams
containing hydrocarbons, then click OK to display the report.
UnitOp
CHEMCAD can also run reports to analyze UnitOp data. The results will display in
either WordPad or Excel, depending on how you have configured CHEMCAD to
handle text reports.
To access any of these items, click Reports to view the report gallery, then select
the appropriate item under the UnitOp heading.
Select
To run a report that covers just the Unit Ops you specify, choose Select from the
Reports gallery. In the Select UnitOps dialog box, specify the UnitOps you want to
include in the report, either by typing in the UnitOp IDs (one per line) or by clicking
on UnitOps in the flowsheet. Click OK to close the dialog box and display the report.
If you select one or more UnitOp icons before running the report, the data will
display without further input.
Batch Results
This report summarizes the results of a batch distillation column simulation at the
end of each operating step.
Spec Sheet
This command exports detailed information about a UnitOp into a preformatted
Excel file. This report is useful for tasks such as soliciting a manufacturing quote for
a piece of equipment.
When you select Spec Sheet from the Reports gallery, the Select UnitOps dialog
appears. You can type in a single UnitOp ID or multiple IDs, click the desired
UnitOp icons on the flowsheet, or click All UnitOps in the dialog to create a spec
sheet for all units on the flowsheet. If you request spec sheets for more than one
UnitOp, the resulting Excel file will include a separate worksheet for each UnitOp’s
data.
For a single UnitOp spec sheet, you can select the UnitOp icon before requesting
the spec sheet, and Excel will open and display the data without further input.
Distillation
CHEMCAD offers several reports that focus on distillation data. To access any of
these items, click Reports to view the report gallery, then select the appropriate item
under the Distillation heading.
Column Profiles
Generates a report detailing temperature, pressure, and flow rate for a distillation
column
Tray Composition
Creates a report that shows the vapor flow rate, liquid flow rate, and K-value of each
component on each stage of a distillation column
Tray Properties
Reports on currently selected stream properties for each stage of a distillation
column
Mass Transfer
For an SCDS distillation column that uses a mass transfer model, provides mass
transfer coefficients, height of transfer units, and estimated height of theoretical
plates (HETP)
Column Diagnosis
For columns that have not successfully converged, provides recommendations for
changing column settings to achieve convergence
Flowsheet
In addition to reports that focus on particular UnitOps and streams, CHEMCAD
offers text reports that provide information about the simulation as a whole. To
access any of these reports, select the appropriate item from the Reports gallery.
Topology
This report provides a listing of all UnitOps in the flowsheet, as well as all stream
origins and destinations.
Thermodynamics
This report lists all components used in the simulation and provides vital
information about the thermodynamics methods used.
User Component
This report lists the physical properties of all user-added components in the
simulation.
Dynamic
This group of reports is used to obtain data about dynamic, or non-steady-state,
processes. Dynamic process simulation is addressed in Chapter 7, Building and Using
a Dynamic Simulation.
Stream History
This report provides stream information recorded over the course of a dynamic run.
Before running this report, you must first use the Record Streams command to select
streams to include, and then run the dynamic simulation.
UnitOp History
This report provides UnitOp information recorded over the course of a dynamic run.
Before running this report, you must first use the Record UnitOps command to
select UnitOps to include, and then run the dynamic simulation.
Column History
This highly customizable report details the data from a single dynamic run of a
column.
Note: Because of this other functionality of UnitOp groups, the order in which you
list UnitOp IDs when setting up these groups is important.
Creating a Group
The quickest way to set up any group is to use the Explorer pane on the left side of
the CHEMCAD screen. Follow these steps to create a stream or UnitOp group:
1. In the Explorer pane, find the top-level item called Groups. Click the triangle
next to Groups to expand this item.
2. Now click either the Streams item or the UnitOp item under Groups, to
bring up the New Group dialog. Replace the default name (such as Group 1)
with a descriptive name for your group, then click OK.
3. In the next dialog box, select the streams or UnitOps for this group, either by
typing in their flowsheet ID numbers (one per line) or by clicking on objects
in the flowsheet. Click OK to close the dialog box.
• Copy: Open a dialog box where you can type a new group name to make an
exact copy of the group. After you click OK, you can then edit the new copy of
the group to fit your needs.
• Delete: Remove this group from the simulation. If you’re sure about deleting the
group, click Yes in the dialog box that appears.
The following specialized items appear on the right-click menu only for UnitOp
groups:
• Run: Run the simulation only for those UnitOps included in this group.
• View: Display a summary report of the UnitOps included in this group.
• Specifications: Bring up the UnitOp specification dialog boxes for each item in
the UnitOp group, starting with the first UnitOp listed.
The following specialized items appear on the right-click menu only for stream
groups:
• Composition: Run a stream composition report for the streams in the group,
using the Stream Composition property set.
• Properties: Run a stream properties report for the streams in the group, using the
currently active Report property set.
Note: The commands to view, edit, select, rename, copy, and delete stream and
UnitOp groups are also offered in the command ribbon, on the Specification tab.
Click the Stream Groups drop-down in the Streams group, or click the UnitOp
Groups drop-down in the UnitOps group, to see a list of existing groups. Hover
over a group name to see the available commands. The same areas of the command
ribbon also offer the Add Stream Group and Add UnitOp Group options.
• Microsoft Word
• Microsoft WordPad
• CSV format
To change your report viewer option, go to the Results group on the Home tab
and choose an item from the Report Viewer drop-down list.
Note: You can also determine the location of the date/time stamp that appears on
your reports, and if needed, specify a path to your copy of WordPad. Start by
clicking the File tab and then selecting Preferences. In the Preferences dialog, click
Report Viewer. In the Report Viewer preferences, you can specify a path to
WordPad if necessary, and choose either Footer or Header as the date/time stamp
location for your reports.
From here, you can click Generate to create a default consolidated report that
includes topology, convergence, mass and energy balances, and the other reports
listed in the dialog box’s left column. If this report is adequate to your needs, simply
click Return to CHEMCAD after generating the consolidated report, to close the
Report Writer dialog box.
If you want something other than the default consolidated report, you can also
use the Report Writer to customize which individual reports to include, what order
to put them in, which flowsheet elements to include, and much more. You can fine-
tune your report settings without closing this dialog box, and then save your report
configuration with a new name so that you can run it again in the future.
Figure 8-08: Typing a new name into the Report Name field
Once you have named the report, you can click Save to save the report locally
(that is, only for this simulation), or click Save As to save the report under My
Simulations\My Reports\Global Reports. Saving in the Global Reports directory
makes the report available to any simulation you may open in the future.
To generate a report that you have saved locally, return to the Report Writer fly-
out menu at the bottom of the Reports gallery. Select Simulation > [Report Name] >
Generate Report. Other options here are Edit to open the report in the Report
Writer, Export to copy it to a global location, or Delete to remove it from the menu.
Figure 8-09: Generating a consolidated report that has been saved locally
Similarly, to generate a report that you’ve saved globally, return to the Report
Writer fly-out menu and select Global > [Report Name] > Generate Report. As with
local reports, you can use this menu to edit, export, or delete a global consolidated
report.
106 CHEMCAD User Guide
Output and Reports
Property Sets
CHEMCAD calculates and stores a large number of data points about the process
streams in your simulations. Some of these items will be of great interest to you,
while others may be useful only in rare situations. A customization feature called
property sets enables you to choose exactly what information to display about your
process streams in the various types of reports.
A property set is a collection of physical data to display about a stream (or a
group of streams). It could include very few items—for example, only temperature
and pressure—or it could show in-depth details about the stream and all of its
components. For every type of text report in CHEMCAD, you can choose a property
set that best fits your needs.
Note: A single property set can be assigned to both of these designations, if desired.
The active tooltip set will determine the contents of the stream tooltips that
appear any time you hover the mouse over a stream. The Quickview property set is
assigned as the tooltip set by default.
The active report property set will be used to determine which stream properties
are included in standard stream reports. The Stream Property set is the active report
set by default.
To change the active tooltip or active report designation, select the property set
name and then click either Set Active Tooltip or Set Active Report in the area below
the list of sets. When you do this, the (Tooltip) or (Report) designation will switch to
the property set that you had selected.
tab, in the Name field, type a meaningful name and then click into the properties list.
The new set’s name is now listed in the left-hand column.
To add properties to your new set, start by expanding the various first-level
options such as Overall, Vapor, and Liquid. Simply click the plus sign next to an item
to expand it and view the second-level options.
Note that when you check the box by a first-level item, you select all the items in
that category. Similarly, clearing a first-level box removes all its second-level items
from the property set. A solid check box indicates that some, but not all, second-level
items are currently checked.
Figure 8-13: Property categories with no options selected (left), all options selected, and mixed
selections
As you saw with editing a built-in property set, you can use the Up and Down
buttons to move properties into the desired order. When you have finished, click OK
to save your changes.
Figure 8-14: The Property Set Library dialog, showing built-in and custom property sets
The left side of this dialog lists local property sets—that is, all property sets that
are available in the current simulation. This includes the three built-in property sets
(Quickview, Stream Composition, and Stream Property), plus any sets you have
created in the current simulation.
If you want to make a custom property set available in the future for simulations
that you open on this installation of CHEMCAD, add the set to the Library Sets list
on the right.
To do this, select the desired set in the Local Simulation Sets list on the left side of
the screen, then click the right arrow between the two lists. The selected set will now
appear under Library Sets, with the designation (Copy) at the end of the set name.
Figure 8-15: Before and after copying a property set to the Library Sets list
It’s recommended that you give the library copy of the property set a unique
name, to avoid confusion. When you have finished, click OK to return to Property
Set Preferences, and OK again to return to the CHEMCAD workspace.
Note: Changes to the Library Sets list will be saved after you click OK, even if
you then close the simulation without saving it. You must save the simulation
file, however, to keep any changes you have made to the Local Simulation Sets
list.
The Library Sets list works as a global repository for a given CHEMCAD
installation. Once a property set is designated as a library set, it is available to use in
any new or existing simulation.
• When you create a new simulation, all library sets will automatically appear in
the local list of stream property sets.
• For an existing simulation, open the Property Set Library dialog box, select the
desired property set in the right column, and click the left arrow to copy it to the
left column.
The commands to insert these items are located on the Drawing tab, in the Insert
group. For each kind of databox, you will need to make specifications to determine
which data is included and how it is displayed.
Stream Boxes
To create a stream databox, start by clicking the Drawing tab. In the Insert group,
click Stream Box. In the Select Streams dialog, you can choose All Streams, Feed
Streams, Product Streams, or Cut Streams, or you can list the specific stream IDs to
include in the stream box and click OK to continue.
The Select a Property Set dialog box displays next. The property set you choose
here (along with any changes you make to that property set) determines which
properties are included in the resulting stream databox.
In this standard property selection dialog, you can add, copy, or edit a property
set, or simply select an existing set from the list at left. When you click OK, the
stream databox with the selected streams and properties displays on the flowsheet.
Once you have created a stream databox, you can move, stretch, or resize it using
your mouse. You can also edit the contents of the databox by right-clicking the box
and selecting Edit Databox.
Figure 8-17: Using the Edit Databox command to change stream box contents
This brings up a property selection dialog much like the one you used to create
the databox, with the title Select New Set or Edit Current Databox Set. Simply add or
delete properties here as appropriate, then click OK to return to the flowsheet and
see your stream databox updated.
UnitOp Boxes
To create a UnitOp databox, click the Drawing tab, then in the Insert group, click
UnitOp Box. Then either type UnitOp IDs in the Select UnitOps dialog box or click
the desired UnitOp symbols on the flowsheet. To include every UnitOp on the
flowsheet, click All UnitOps in the lower portion of the dialog, or click anywhere in
the workspace and then press [CTRL-A].
When you complete your selections and click OK, the UnitOp databox appears
on the flowsheet.
TP Boxes
CHEMCAD can create databoxes called TP boxes that display any combination of
temperature, pressure, and flow rate for all streams or selected streams on a
flowsheet.
To add TP databoxes, click the Drawing tab, then in the Insert group, click TP
Box. In the TP Box Settings dialog box, first select an option at the top, to determine
whether to add TP boxes for all streams or only for the streams you select.
In the Display column, select items from the drop-down list in each field to
determine which stream properties to display and in what order. Use No selection
as appropriate if you want to display fewer than four properties.
In the Number format column, make a selection in each field to determine how
numbers will display in the TP boxes. In the Digits column, type the number of
digits to display after the decimal point. You can also choose whether to display
stream IDs (enabled by default) and engineering units.
The Preview box displays a dynamic sample of how the items you’ve selected
will appear in the TP boxes. Note that the preview area does not reflect any changes
you may have made to your default font size or style.
When you finish making your selections in the TP Box Settings dialog box, click
OK. If you’ve chosen to make TP boxes for all streams, the TP boxes will appear on
the flowsheet right away. If you’ve opted to select the streams from the flowsheet,
you’ll see a Select Streams dialog box; type the stream numbers (one per line) or click
on the stream lines in the flowsheet to select streams, then click OK to create the TP
boxes.
An Excel range box is a dynamic link between CHEMCAD and the Excel
worksheet. As data is updated and saved in the selected cell range, the range box can
automatically update to reflect those changes. To view the most up-to-date data in
your Excel range boxes at any time, click the View tab and then select Data Boxes in
the Refresh group.
Click and drag the title block to move it to the desired location on the workspace.
Note: Be careful to use only the corner handles when resizing an image. Using the
handles along the sides of the box will distort the image, whereas using the corners
will preserve the image’s original shape as you scale it to a larger or smaller size.
You can group the image and the title block together so that they will behave as a
single unit. To do this, first click the image, then hold down [SHIFT] as you click
anywhere on the title block. Then with both items selected, click the Arrange drop-
down on the Drawing toolbar and select Group.
Now when you drag the title block to a different location, the image will move
along with it. If you ever want to remove or replace the image, you can select the title
block and then use the same method with the Ungroup command. Once the items
are ungrouped, you can select the image independently from the title block and
delete it.
If you already have a custom title block, start by selecting it on the flowsheet.
Right-click and select Copy from the pop-up menu. Then go to the Tools tab and
click Title Block Designer in the Flowsheet group.
In the Select Title Block dialog, choose the .tbd file that you used to start your
customized title block, or any of the other .tbd options, and click Open. This brings
up a new tab on the CHEMCAD workspace, called Title Block 1. The title block you
chose is displayed in its own workspace tab. At the top of the screen, a special Title
Block Designer tab now displays, offering drawing objects and other items specific
to customizing a title block.
If you were starting a new customized title block, you could begin changing the
text and adding an image, as discussed before. But if you have copied in a title block
with your custom content, you can simply right-click in the workspace and select
Paste. This places your customized title block on the tab; you can now select and
delete the title block with the placeholder text.
You will probably want to delete some of the specific text that you copied in with
the title block, such as a date, title, or drawing number. You could choose to add
your own placeholder text, for example to suggest a standard date format, or you
may simply leave a character such as X to provide a place for users to begin typing.
To make your title block available for future use, you must save it as a .tbd file.
In the Title Block Designer tab’s Workspace group, click Save As, and then provide
a unique name. When you click Save, the workspace tab will display your new title
block name.
Close the tab to return to the main CHEMCAD workspace and the open
simulation. To test your new custom title block, click the Drawing tab, then in the
Insert group, click Title Block. Choose your new .tbd file and click Open. The
custom title block will appear on the workspace.
Note: Turning off a layer only hides its assigned flowsheet objects from view. Having
a layer hidden does not in any way affect the way the simulation runs, nor does it
change any stream or UnitOp properties.
The Explorer pane also includes a top-level item called Layers, which lists any
layers that you have created in the current simulation. On this list, you can see at a
glance which layers are currently visible ( ) and which are hidden ( ).
Figure 8-23: The Layers entry on the Explorer pane, listing visible and hidden layers
Note: To change the name of a layer you have created, either select it in the Layers
drop-down menu or right-click it in the Explorer pane list, then choose Rename. In
the New Layer dialog, type the new name and click OK.
• In the Explorer pane, right-click the top-level Layers item and choose Remove
Selected from All.
Deleting a Layer
To remove a layer from the simulation, do either of the following:
• On the View tab, click Layers, then select the desired layer from the drop-down
list and click Delete.
• In the Explorer pane, right-click the name of the desired layer and choose Delete.
When you delete a layer, it disappears from the Explorer pane and the drop-
down layer list. If the deleted layer had been hidden, the objects assigned to it now
reappear.
As you become more familiar with the way that CHEMCAD works and the various
options and tools that are available, you may want to make your own additions—
either for specialized items or for those you use frequently. You can customize
CHEMCAD in several ways that save you time by streamlining and simplifying
your workflow. These include:
• Creating and using stream and UnitOp templates
• Adding custom components to CHEMCAD’s component database
• Defining custom thermophysical rules
• Customizing UnitOp palettes and color schemes
• Making your own UnitOp symbols to add to existing or custom palettes
• Building custom UnitOps
• Creating custom dialog boxes for UnitOp settings
• Customizing costing calculations
This chapter discusses all these types of customization, starting with the simplest
procedures and then moving on to more complex customizations that require some
programming experience.
Flowsheet Templates
One of the most effective ways to save time when creating CHEMCAD simulations
is to make use of stream and UnitOp templates. A template is simply a set of
characteristics, which you assign a name and save for later use. When you set up
stream or UnitOp specifications that you know you’ll need to recreate in the future,
you can create a template of that stream or UnitOp. You can then duplicate that item
within the same simulation—or in any other simulation—with just a few mouse
clicks.
Creating a Template
To create a stream template, first create the stream you want to clone and give it all
the characteristics you want to include in the template.
Then find this stream on the Explorer pane’s Simulation tab. Expand the
Flowsheet item, then expand the Streams item, and finally double-click the
applicable stream ID. This brings up an item called Save. Click the word Save to
display the Enter Template Name dialog box, then type a name for your new stream
template and click OK. The new template name is now listed beneath the Save item.
To create a UnitOp template, select the appropriate UnitOp ID in the Explorer
pane, and then follow the same procedure used to create a stream template.
Applying a Template
To apply a stream template, first expand the main Flowsheet item for the stream to
be affected, either by clicking the triangle icon to its left or by double-clicking the
stream name.
When the stream item is expanded, you’ll see the Save item below it, followed by
the names of all the stream templates that you have created. Click the name of the
template you want to apply, then choose OK to confirm that you want to apply this
stream template.
Use the same procedure to apply a UnitOp template. Select the UnitOp to be
affected and then expand it in the Explorer pane to apply the desired template. Bear
in mind that for a given UnitOp, only templates for the relevant UnitOp type will be
listed.
Note: Any stream or UnitOp template that you create will be available for use with
all other simulations on the same installation of CHEMCAD, until and unless you
delete the template.
6. Normally, you’ll need to click Create, which brings up the Save As dialog
box. Navigate to the location you want for your custom component database,
give the database a name, and click Save. If you want to add a database that
someone else has created (generally in a network location), you can click
Connect, which brings up an Open dialog box; navigate to that database’s
location, highlight the database, and click Open.
7. The Manage Component Databases dialog box now lists the database that
you created or selected. Click OK to continue.
8. In the Select Destination Database dialog box, the new database you have just
named is now listed; highlight it and click OK.
9. The View/Edit Component Data menu now appears. Click any item on the
menu to access a dialog box with options for defining your new component.
After defining as many characteristics as possible, click Exit to close the
menu.
The new component is now available to add to your current simulation and all
future simulations. To return at any time to make changes to a user-defined
component, go to the Component Database tab and do one of the following:
• In the System Database group, click View/Edit Component to bring up the
Select Single Component dialog box, which lists all available components.
Highlight the component you want in the list and click OK to bring up the
View/Edit Component Data menu.
• In the Simulation Database group, click View Components to bring up the
list of components in the current simulation. Double-click the component you
want in the list (or highlight the component and click View/Edit) to bring up
the View/Edit Component Data menu.
2. Select the user-added component that you want to regress and click New.
This brings up the Edit Regression Set dialog box.
3. Select a regression type and provide a descriptive name for the data
regression, then click OK. This brings up a dialog box that displays
parameters for the selected regression type.
4. Verify the data on this dialog box, making additions or changes as necessary,
and then click OK. This brings up a dialog box for data entry.
5. Enter your experiential data points in the cells provided. You can enter a
value in the Weight_factor column to weight the regression toward one or
more data points. When you have entered all of your data points, click OK.
Note: You can paste a contiguous range of cells from an Excel worksheet into the
cells in this dialog box.
Note: Before you define a petroleum assay, make sure that you have specified in
your component list, as appropriate, water and any light ends that exist in the assay.
1. Click the Thermophysical tab, then in the Petroleum Assay group, click
Initialize.
2. In the Select Streams dialog box, enter the appropriate stream number(s) and
click OK.
3. In the Hydrocarbon Correlation dialog box, select the appropriate
correlations for your curve, or use the default selections and click OK.
4. This brings up the Curve Temperature Cut Ranges dialog box. For each cut
range that you want to define, provide a beginning and ending temperature,
and enter the number of points that you want to define as discrete
pseudocomponents within that range. Click OK to continue.
5. In the Bulk Properties dialog box, specify a petroleum assay type and enter a
total flow rate and bulk gravity for the stream. You can make other entries
here as needed, but only these three items are required. Note that if you have
viscosity data that you want to use, you must check the Viscosity box here.
Click OK to continue.
6. In the resulting dialog box, enter the data from your assay, specifying the
volume percentage and boiling temperature for at least five data points. Click
OK to continue.
7. The next dialog box is optional. Enter a gravity curve from your assay, listing
the volume percentage and specific gravity for at least five data points. Click
OK to continue.
8. The next dialog box is also optional. If you have light ends and water defined
in your assay, enter volume percentage data here for all relevant components.
Click OK to continue.
9. If you checked the Viscosity box on the Bulk Properties dialog, you will now
see the Viscosity Data dialog box. Enter your viscosity data and click OK.
10. The pseudocomponent properties now display in a tab in the main
CHEMCAD window. You can review and print these results, and leave the
tab open as long as you like. To return to the main workspace and your
flowsheet, simply click the far left tab, which displays the name of your
simulation.
11. To see the list of pseudocomponents that you have created, edit the
properties for the stream you selected. The pseudocomponents will be listed
after pure components, with names that begin with NBP.
Customizing Thermodynamics
Occasionally, you may find that none of the thermodynamic models built into
CHEMCAD serve your needs for a particular simulation. If this should happen, you
can take one of two approaches to handling thermodynamics for the simulation:
either create your own K-value or enthalpy model or create your own mixing rule.
After adding a custom enthalpy model, you can select it on the Enthalpy Models
tab of the Thermodynamic Settings dialog box, by using the Global Enthalpy Option
setting called ADDH.
3. Copy the existing subroutine and paste the code below the example in the
code window. Rename the new subroutine copy.
4. Edit the new subroutine as needed to achieve the result that you want.
5. Return to CHEMCAD by either of two methods:
• Use [ALT-TAB] or the Windows taskbar, leaving the VBA editor window
open.
• Click the View CHEMCAD button at the far left end of the VBA editor’s
toolbar to close the editor window.
Note: You can also use the [ALT–F11] key combination to toggle between CHEMCAD
and the VBA editor.
6. Save the current CHEMCAD simulation, then expand the relevant Explorer
item again to see your newly defined item in the list.
Figure 9-08: Selecting a VBA-defined reaction in the Kinetic Data dialog box
4. When you have defined the last reaction, click OK to return to the main
CHEMCAD window.
Renaming a Palette
To change the name of any palette, first open the palette in question. Then right-click
the palette heading and select Rename. In the Rename Palette box, type the name
you want to use for the palette and click OK. The palette will now display the new
name.
Note: The Rename command is very useful when you have just created a new
custom palette, as the initial name for all new palettes is New.
Note: Using two colors gives the symbol a three-dimensional appearance; to create a
flat look, choose the same color for the primary and secondary options.
Figure 9-10: Default Grayscale colors in the Edit Color Scheme dialog
Choose new colors and then click OK. The symbol appears with the colors you
selected on the current palette.
Figure 9-11: The standard Equilibrium Reactor symbol with (from left) Grayscale, System Color,
two-tone custom, and single custom coloring
Repeat this process for any other UnitOp symbols for which you want to create
custom colors. The changes you make in a custom color scheme will affect only those
palettes to which you assign the scheme.
You can remove a custom color scheme simply by right-clicking any palette
heading and selecting Delete Color Scheme > [scheme name]. Before you do this, be
sure the scheme you are deleting is not currently in use by any palettes.
2. Drag a symbol of the desired size from the palette to the workspace.
3. Right-click the symbol on the flowsheet and select Copy.
4. Click back to the UnitOp Designer tab.
5. Right-click any blank area and select Paste.
You can now draw your new symbol to a scale that matches this symbol. Be sure
to delete the borrowed symbol, along with any drawing objects that you do not want
to include, before continuing.
Note: Placing ports precisely on a symbol outline can be challenging when done with
a mouse. Alternatively, you can use your keyboard’s arrow keys to fine-tune the
position of a selected port.
Specifying Ports
Once the ports are all in the correct locations, you can specify them as desired. There
are two specifications available for UnitOp ports: Index and Link Direction.
The Index setting determines the order in which the ports will be calculated
within the UnitOp. By default, the first inlet port that you add is assigned index 1,
CHEMCAD User Guide 139
Customizing CHEMCAD
the second is assigned index 2, and so forth; outlet ports are also numbered in this
way.
The Link Direction setting is optional. When specified, it determines the
orientation of the stream segment entering or exiting a particular port. Link
orientations are given as cardinal directions. For example, you may want all the inlet
ports on the left side of a column to enter horizontally from the left, or the outlet port
on the bottom of a vessel to exit downward, regardless of where connecting UnitOps
are located.
To change the assigned order of a port or specify its link direction, right-click the
port and select Port Identification.
The Select New Port Index dialog suggests a new Index value, which you can
keep or change. To specify the direction of stream entry or exit from the port, select
the desired direction from the Link Direction drop-down list. When you have
finished specifying the port, click OK to close the dialog box.
Once you have viewed or changed the settings for a particular port and then
closed the dialog box, the port number displays next to the inlet or outlet dot. It is
recommended that you specify (or at least verify) the index setting for each inlet and
outlet port before continuing.
3. Click and drag to select the UnitOp icon and any drawn additions, then right-
click and select Publish to Palette.
4. On the UnitOp Symbol Properties dialog, specify the symbol’s name, type,
and description. When you click OK, the new UnitOp symbol is published to
the specified UnitOp subpalette.
Whichever method you use to program the calculations of your UnitOp, you will
likely need to create a dialog box to provide a user interface. A dialog box enables
users to send information into your UnitOp, for example the number of stages for a
distillation UnitOp. No matter what method you use to program your UnitOp, you
will use the Dialog Editor program to create the user interface.
CHEMCAD enables you to exchange data with other programs through a variety of
methods. This saves time, effort, and the potential for keystroke error and data
omissions. In some cases, these data interfaces can enable CHEMCAD to link
directly into your plant information systems to run simulations without human
intervention.
The data interfaces that CHEMCAD uses are as follows:
• The Excel Data Map interface, which can link any value in a CHEMCAD
simulation to any cell in an Excel worksheet, or vice versa (note that running
CHEMCAD simulations from Excel requires a COM interface, described
below)
• The Visual Basic Application interface, which enables you to build custom
reactions, mixing rules, and UnitOps
• The OPC interface, which permits any OPC Client application to access
values in a CHEMCAD simulation
• COM interfaces, which allow any COM-enabled program (such as MATLAB)
to access and control a CHEMCAD simulation
With Excel Data Mapping, you can quickly and easily get the most of
CHEMCAD/Excel integration, even if you have no experience with Visual Basic or
Excel programming. In fact, you can use and benefit from this feature even with very
little knowledge of the Excel program.
To use Excel Data Mapping, you must first create one or more Data Maps, and
then set up rules for the execution of each Data Map in use.
2. Click the Browse button and locate the target workbook. Select the workbook
file and click Open.
3. In the cell next to Excel Worksheet Name, type the name of the worksheet to
which you want to link your simulation.
Note: If you need to verify the name of the worksheet, you can click the Open button
to launch Excel and view the workbook.
4. Double-click the cell below Map Rule to see a drop-down list of mapping
options:
• To Worksheet Only enables you to send data from streams or UnitOps in
CHEMCAD to the selected worksheet.
• To CC Only enables you to send data from any cell on the worksheet to
the selected stream or UnitOp parameter in your simulation.
• For data reconciliation enables you to manipulate the data using
CHEMCAD’s Data Reconciliation feature.
Figure 10-02: Selecting a Map Rule option in the Excel Data Map Editor
5. Double-click the cell below CC Obj Type to see a drop-down list of mapping
options:
• Stream enables you to link an Excel cell or cell range to a stream on the
flowsheet.
• UnitOp enables you to link an Excel cell or cell range to a UnitOp on the
flowsheet.
• Misc enables you to change dynamic flowsheet settings.
6. Click the cell below CC Obj ID. Type the ID number of the stream or UnitOp
to which you want to link.
7. Double-click the cell below Par ID to see a drop-down list of parameters for
the selected UnitOp or stream. Scroll down and select an option from the list.
Note: When you are importing cell data into CHEMCAD, the list of parameter
options is limited, as many values in a CHEMCAD simulation are calculated based
on other values.
9. Click the cell below WrkSht Cell/Range. Type the cell address or cell range
to which you want to link. Cell addresses should be formatted with the
column letter and row number, e.g., A1 or D17. Cell ranges should be
formatted as two such addresses (representing the range’s first and last
values) separated by a colon, e.g., A1:A12 or B5:E20.
10. If you are performing a data reconciliation, you can use the Weight column
to give certain items in the reconciliation more importance than others.
11. Repeat the procedure until you have specified all the cells or cell ranges that
will link to your simulation.
12. When you are ready to save the Data Map, first make sure the Tools tab is
selected. Then in the Data Map group at the left end of the ribbon, click Save
Data Map As. Type a name for your Data Map and then click OK. The newly
created Data Map now appears in the View/Edit drop-down list in the Data
Map group.
13. To leave the Data Map open and return to your simulation, use the tabs at the
bottom of the main CHEMCAD workspace. To close the Data Map, click the
red X button on its tab at the bottom of the workspace.
2. Click the square button next to the first field in the Select Data Maps column
to bring up the Select Data Map dialog box.
3. Select the name of the Data Map for which you want to set rules, then click
OK to return to the Data Map Execution Rule dialog box. Repeat this step for
all other Data Maps whose rules you want to set up at this time.
4. In the Before Simulation Runs field next to each selected Data Map, click the
drop-down list to choose an action for that Data Map to perform before
calculations begin:
• Do Nothing performs no action before the simulation is run. You might
use this option to disable a Data Map temporarily.
• To Workbook sends the requested data to Excel before running the
simulation. You might use this option when you want to pull data from
inlet streams or UnitOp specifications.
• To CHEMCAD sends the requested data in Excel to CHEMCAD before
running the simulation. You might use this option when you want to feed
data to inlet streams or UnitOps with data from the Excel worksheet.
5. In the After Simulation Runs field next to each selected Data Map, click the
drop-down list to choose an action for that Data Map to perform after
calculations are complete:
• Do Nothing performs no action after your simulation has run. You might
use this option to disable a Data Map temporarily.
• To Workbook sends the requested data to Excel after running the
simulation. You might use this option when you want to send data from
streams or calculated parameters of UnitOps to the workbook in Excel.
6. When you have configured all the Data Maps that you want to use, click OK
to save your rules and close the Data Map Execution Rule dialog box.
You can now run the simulation. If you open the Excel files that are linked to the
simulation, you will be able to see the parameters of streams and UnitOps related to
the Excel Data Map. You can also perform your own calculations in the workbook
based on the data linked to CHEMCAD.
Specification Sheets
Using the interface with Microsoft Excel, CHEMCAD allows you to output
simulation data to an Excel spreadsheet resembling a vendor specification sheet, as
discussed in Chapter 8, Output and Reports. Customizing these spec sheets saves you
time by outputting data in the format required by your company or vendor.
To customize the spec sheet for a specific UnitOp type, edit the corresponding
Excel spreadsheet in the CHEMCAD templates directory. A typical pathname for
this directory is:
C:\Program Files\Chemstations\CHEMCAD NXT\templates
If the UnitOp type you want is not represented by the Excel files in this directory,
you can copy the generic specsheet.xls file and use it as a template for a new UnitOp
spreadsheet.
Place the copy in the same directory, and make its file name the standard four-
character abbreviation for the UnitOp type in question. For example, to create a spec
sheet template for the Flash UnitOp, you would need to name the file copy flas.xls.
See the CHEMCAD Help information about your specific UnitOp if you need to look
up this abbreviation.
Before you continue, you will need to turn off the Read-only attribute for the
new spreadsheet file. The quickest way to do this is to right-click the file within the
Windows Explorer, select Properties, and then clear the Read-only check box in the
Properties dialog box.
Once the copy is renamed and the Read-only attribute is turned off, you can
open the spreadsheet and edit it as needed.
OPC Applications
OPC can be applied as follows:
• Inferential sensors: Sometimes called soft sensors, inferential sensors use one
or more measured variables to estimate another variable. Using CHEMCAD
simulations and data from your plant’s DCS, you can embed simulations to
provide data such as concentrations, heat duty, and fouling factor, which
would not normally be available.
• Operator training: You can couple an operator HMI to a dynamic simulation
to create a training simulator that can help train operators in a safe and
effective way.
OPC Compliance
Chemstations is a Member of the OPC Foundation, an organization devoted to
maintaining the OPC standards. CHEMCAD has been certified for, and interop
tested for, OPC DA standard 2.05a.
Note: Most of the data items in a simulation have engineering units associated with
them. In these cases, we usually define two separate tags, one containing the data
value and the other containing the units string. All units strings are read only from
OPC. The units strings are governed by the settings inside the simulation.
COM Interfaces
Component Object Model (COM) is a Microsoft-standard platform that enables
programs to share content such as data and calculation routines. This interface
makes it possible for other programs to control a CHEMCAD simulation.
CHEMCAD acts as a COM server, so any program that can act as a COM client
can be made to interface with CHEMCAD in this way. If you aren’t certain whether
your application can act as a COM client, check with the software vendor.
Note: Some values are read-only. For example, VBClient does not allow you
to change a stream’s total flow rate directly; you must instead change the
component flow rates to make a change to the total flow rate.
Sub LoadCHEMCAD()
strJobName = ""
selUpdateStrUopData = True
selOK = False
End If
Call UpdateVersion
End Sub
Montmorillonites have both Br6nsted and Lewis acid sites and when exchanged with
cations having a high charge density produce highly-active catalysts for proton-catalysed
reactions. Intercalated organic molecules are mobile and can be highly polarized when
situated in the space between the charged clay layers. These exchanged montmorillonites
have been successfully used as catalysts, e.g. for the dehydration of alcohols to di-alkyl
ethers (Ballantine et al., 198 l a), the condensation of primary amines to secondary amines
(Ballantine et al., 1981b) and the esterification of organic acids by alkenes (Ballantine et
al., 198 lc); all these are thought to be interlamellar reactions.
The present study is also concerned with esterification, and examines the catalytic
activity of different ion-exchanged Wyoming bentonites in the reaction of ethylene and
acetic acid to yield ethyl acetate. This difficult reaction (equation l) requires catalysts with
strong Br6nsted activity:
EXPERIMENTAL
Hydrogen-bentonite was made by ion-exchanging Wyoming bentonite with cold 5 M
sulphurie acid, washing to remove all extraneous ions, and then drying at 80~ in air. AI-,
Cu(II)-, Fe(III)- and Cr(III)-bentonites were made in a similar manner by exchange with
0.5 M solutions of aluminium sulphate, copper(II) sulphate, iron(III) nitrate and
chromium (III) nitrate, respectively.
Several preparations of H-bentonite were shown by X-ray diffraction to have a basal
d001 spacing of between 12.0 and 12.9/k, by thermogravimetric analysis to contain about
8% wt/wt water (probably present as a monolayer), and by adsorption to have a BET
surface area of 40-60 m2/g. Preparations of Al-bentonite had a basal d0o1 spacing of
14.0-14.5 /k, about 8% wt/wt water, and a BET surface area of 50-60 mZ/g. Similar
values were obtained with other ion-exchanged bentonites used in this work.
9 1983 The Mineralogical Society
432 R. Gregory et al.
Batch reactions were carried out in a stainless steel autoclave (100 ml) charged with
acetic acid (80 g), catalyst (10 g) and sufficient ethylene gas to give a 55 bar pressure at a
reaction temperature of 200~ The reactions were carried out for 2.5 h, and the ethylene
to acetic acid molar ratio was approximately 2:1. Gas was vented from the cooled
autoclave, and the liquid products weighed and analysed by gas c h r o m a t o g r a p h y using a
88 • 5' P o r a p a k Q column with a flame ionization detector.
H+ -- 31
AP+ 5.8 13
Fe 3+ 2.7 11
Cr 3+ 4-3 13
Cu 2+ 1-4 7
Na + 0.4 1
Clay catalysts for ethyl acetate 433
Increases in catalyst activity generally correspond to increased charge density of the
exchanged cation. The higher the charge density of the exchanged cation, the greater will
be the polarizing power of these cations in the interlamellar space inducing ionization of
acetic acid and any remaining solvent water molecules. The strong Br6nsted acidity of
these ion-exchanged clays has been suggested to derive, at least in part, from the enhanced
polarization of the solvent water molecules (Thomas, 1982).
50
40
30-
\
~ 20-
10-
i i / i
100 200 300 40O
Catalyst drying temperature (~
FIG. 1. Variation in molar yield of ethyl acetate from acetic acid with differentpre-reactionheat
treatments. --Al-bentonite, -H+-bentonite.
434 R. Gregory et al.
With drying temperature above 200 ~C, further decreases in intercalated water molecules
cause the edges of the lamellar structures to collapse irreversibly, and access to the
interlamellar sites is therefore lost. At even higher temperatures (300~ total lamellar
collapse occurs, leaving only exposed surface activity. This suggests that the bulk of the
reaction is occurring in interlamellar space, since when this is denied to the reactants
catalyst activity is drastically reduced.
H-bentonite behaved in a similar manner to the Al-bentonite catalyst but the maximum
catalytic activity was displaced to lower drying temperatures (Fig. 1). Drying at 200~
was sufficient to produce a collapsed catalyst which gave a 5% yield of ethyl acetate.
CH 2 H CH 3 ~ CH2CH 3 + O ~ C H s (5)
The proposed mechanism is consistent with increased catalytic activity observed with
increased charge density of the exchanged cations, giving greater polarization of acetic acid
and increased Br6nsted acidity. Also, with hydrogen bentonite an additional source of
protons is provided.
Hydrogen- and Al-bentonites recovered from several reactions were shown by Raman
spectroscopy to have very small amounts of low-molecular-weight polyethylene deposited
on the catalyst. It is likely that polyethylene is formed on both the external and
interlamellar surfaces; in a continuous reaction this could build up and block reactant
Clay catalysts f o r ethyl acetate 435
access to reactive interlamellar sites and lead to catalyst deactivation. The mechanism
leading to polyethylene formation involves ethyl carbocation addition to ethylene followed
by further ethylene addition (equation 6).
CH3~H2 C.~=CH2 + C.2=CH~ +
CH3 (CH2)2CH 2 , CH3(CH2)4CH 2 (6)
This reaction might also be expected to produce butyl and hexyl acetates by reaction of
intermediate carbocations with the more a b u n d a n t acetic acid (equation 4) but, even if
present, the amounts produced were too small to be observed by gas chromatographic
analysis of the liquid reaction products. Thus it is believed that ethylene oligomerization is
only a very minor side reaction.
CONCLUSION
This work has shown that W y o m i n g bentonites exchanged with cations of high charge
density are efficient and selective catalysts for the production o f ethyl acetate from ethylene
and acetic acid. The reaction occurs in the interlamellar space where it is p r o p o s e d that
strong Br6nsted acid sites on the clay coupled with highly polarized reactants lead to the
formation of ethyl acetate.
ACKNOWLEDGMENTS
The authors wish to thank the British Petroleum Company plc for permission to publish this paper.
REFERENCES
BALLANTINE J.A., DAVIES M., PURNELL H., RAYANAKORNM., THOMASJ.M. & WILLIAMSK.J. (1981a)
Chemical conversions using sheet silicates: Novel interlamellar dehydrations of alcohols to ethers and
polymers. J. C. S. Chem. Comm. 427-428.
BALLANTINE J.A., PURNELL H., RAYANAKORNM., THOMAS J.M. & WILLIAMSK.J. (1981b) Chemical
conversions using sheet silicates: Novel intermolecular elimination of ammonia from amines. J. C. S.
Chem. Comm. 9-10.
BALLANTINEJ.A., DAVIESM.E., PURNELLH., RAYANAKORNM., THOMASJ.M. & WILLIAMSK.J. (1981c)
Chemical conversions using sheet silicates: facile ester synthesis by direct addition of acids and alkenes. J.
C. S. Chem. Comm. 8-9.
FRENKELM. (1974) Surface acidity of montmorillonites. Clays Clay Miner. 22, 435-441.
MORTLANDM.M. & RAMANK.V. (1968) Surface acidity of Smectites in relation to hydration, exchangeable
cation and structure. Clays Clay Miner. 16, 393-398.
THOMASJ.M. (1982). Sheet silicate intercalates: New agents for unusual chemical conversions. Pp. 55-99 in:
Intercalation Chemistry (M. S. Whittingham & A. J. Jacobson, editors). Academic Press, New York.
HETEROGENEOUS AZEOTROPIC DISTILLATION
Heterogeneous azeotropic distillation is a widely practiced process for the dehydration of a wide
range of materials including acetic acid, chloroform, ethanol, and many higher alcohols. The
technique involves separating close boiling components by adding a third component, called an
entrainer, to form a minimum boiling, normally ternary azeotrope which carries the water
overhead and leaves dry product in the bottom. The overhead is condensed to two liquid
phases; the organic, "entrainer rich" phase being refluxed while the aqueous phase is decanted.
Given the non-idealities, the phase splitting, the distillation boundaries present, and the possible
existence of multiple steady states in such a system, columns like these can be extremely
difficult to simulate and to operate. A systematic approach to the problem can save you many
headaches.
1. You need to start with two triangular plots: The residue curve map and the binodal plot. The
residue curve map should have the liquid phase envelope superimposed. The binodal plot
should be at anticipated condenser conditions.
2. The key feature of feasible heterogeneous azeotropic distillation is that entrainers and top
tray vapor compositions are selected to generate liquid-liquid tie lines which straddle at least
one of the distillation boundaries dividing the two regions containing the two components to
be separated. In this way, the "jump effect" can be exploited, whereby each column is
provided with a feed composition in the required (different) distillation regions. This is why
the condenser must be two-liquid phase and we reflux the organic phase while decanting
the aqueous phase.
4. The distillate and bottoms product must lie on the same residue curve.
5. The feed, distillate, and bottoms product must be colinear; i.e., all lie on the same straight
material balance line.
6. All feed to the column (reflux, makeup, and process feed) should be entered near the top of
the column.
7. The composition of the vapor leaving the top tray must be near but not necessarily at the
ternary azeotrope.
8. If at all possible (and it generally is possible) the column should be operated such that only
one liquid phase exists on the stages. Since the condenser must be operated in the
heterogeneous region, this means that the vapor coming from the top tray must be in
equilibrium with a single liquid phase, but must condense to two liquid phases. This narrows
the selection of top tray vapor compositions considerably and in fact can only be achieved
by careful manipulation of the condenser operating conditions and/or a mix of the decanter
organic and aqueous phases in the reflux.
9. It is important to note that the liquid boiling envelope is not a simple liquid-liquid binodal
curve at a fixed temperature, but the projection of the heterogeneous liquid boiling surface
onto the composition base plane. This is critical because the top tray equilibrium liquid
composition must lie outside the liquid boiling envelope. It is not enough to lie outside the
condenser binodal plot heterogeneous envelope.
10. The composition of the two-liquid phases generated in the condenser must be taken from tie
lines on a binodal plot calculated at condenser conditions, not top tray conditions.
11. The relative proportions of the two-liquid phases in the condenser, φ, is given by the lever
rule;
ye, i - x aq, i
φ =
ye, i - x org , i
12. The vapor composition in equilibrium with a (liquid) point on a residue curve must lie on the
tangent to the residue curve. For homogeneous systems, each residue curve has an
associated vapor boil-off curve, and they are related by this tangency condition. However,
in the heterogeneous region there is only one vapor boil-off curve, namely, the vapor line.
Therefore, the vapor composition in equilibrium with a point on a heterogeneous residue
curve lies at the intersection of the tangent to the residue curve and the vapor line.
Please note that in the two-liquid phase region, the vapor line lies very close to the
heterogeneous distillation boundary. However, these two curves coincide exactly only when
the distillation boundary is linear. In all other cases, the vapor line must lie to the convex
side of the distillation boundary as required by the tangency condition.
All liquid compositions lying on the liquid boiling envelope will produce equilibrium vapor
compositions on the vapor line. As the liquid composition moves away from the liquid
boiling envelope, into the homogeneous region, the corresponding equilibrium vapor
composition moves off the vapor line. However, the cusp in the vapor surface on either side
of the vapor line is normally quite steep.
• Small changes in bottoms products purity specs can significantly impact the column
temperature profile and entrainer requirements.
• Small changes in the reflux ratio can dramatically change the temperature profile.
• Small fluctuations in pressure can move the overhead composition outside the
heterogeneous region, thus causing column failure.
• Small losses of decanter interface can cause the entire column sequence to shutdown.
ETHANOL-WATER-nPENTANE EXAMPLE
Consider the separation of ethanol and water using n-pentane as the entrainer. In this system
all three binaries form minimum boiling azeotropes and a heterogeneous, minimum boiling
azeotrope (low boiler) is formed by the ternary.
Assuming the thermodynamic model has been properly set up (the topic of another discussion),
we should begin by looking at a residue curve map and a binodal plot for the system. The
residue curve map should have the liquid boiling envelope superimposed. Together the two
diagrams should look like this:
0.9
0.8
0.7
Mole Fraction Ethanol
0.6
0.5
0.4
0.3
0.2
0.1
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Mole Fraction N-Pentane
As you can see the map has distillation boundaries which cannot be crossed with conventional
distillation. These boundaries partition the system into three regions. If the feed is in region one,
a conventional distillation system will drive the ternary azeotrope to the top and pure water to the
bottom. If the feed is in region two, the azeotrope will still go to the top but pure n-pentane will
come out the bottom. Likewise, a feed in region three will produce the azeotrope at the top and
pure ethanol out the bottom. These are the best splits that can be produced.
Obviously, then to dehydrate ethanol we want to operate in region three. Ethanol and water will
come in at the binary azeotrope (89.5% ETOH, 10.5% H2O), but by controlling the amount of
benzene used, and by grouping all feeds near the top of the column, we can force the combined
feed into region three.
We don’t actually need or even want the vapor leaving the top tray to be right at the azeotrope.
Not only would this require unnecessary costs (stages and/or reflux), but it will cause multiple
liquid phases to form on the top trays of the column. This can make operations difficult.
Therefore, we want to produce a tops vapor which is close enough to the ternary azeotrope to
phase split in the condenser but not on the trays. In other words, we want the composition of
the vapor leaving the top tray to be such that its equilibrium liquid has a composition outside the
two-phase region, but the vapor composition itself is inside the two-phase boundary. This
leaves us with a narrow range of choices, all lying near the two-phase boundary on the binodal
plot.
Column feed = 242 lbmoles / hr. Ethanol and 40.58 lbmoles / hr. water
Column pressure = 50 psia
Condenser Temperature = saturated at 44 psia
Ethanol purity is to be 99.99%
We can now use the residue map and the binodal plot to do a preliminary material balance
around the column.
Step 1. Find the compositions of the top tray vapor, the condenser aqueous phase, and the
condenser organic phase.
Given that we want essentially pure ethanol as a product, our first task is to "select" the vapor
composition to go out the top tray. The composition must meet the following criteria:
(i.) The liquid in equilibrium with the selected vapor must be single phase at system
conditions.
(ii.) The vapor must condense to two liquid phases at condenser conditions.
(iii.) The composition of the two liquid phases which form in the condenser, must lie in different
distillation regions; one aqueous (to be decanted), the other organic (to be refluxed).
Only those compositions in the region of the shaded box will meet these criteria (see figure 1).
An exploded view of this area is shown in figure 2. The heavy black line represents the two
liquid phase boundary. The dotted lines connect acceptable vapor-liquid equilibrium
concentrations. The point in the two-phase region represents the possible top tray vapor
composition, and the point in the one liquid phase region is the composition in equilibrium with
that vapor.
In order to actually generate this vapor in the column, it will be necessary to reflux some of the
decanter aqueous liquid.
Since these are preliminary calculations and criteria (i) has the smallest impact on the overall
material balance, we will not try to satisfy this condition just yet. Instead we will focus on criteria
(ii) and (iii). These can be satisfied by picking a tie line that passes through the shaded area of
Figure 1.
As you can see such a tie line is not unique, so we must choose one that looks "best". The
closer to the azeotrope we get, the harder it will be to satisfy criteria (i) later on and the more
stages we will require. The closer to the two phase boundary we get, the greater the required
reflux. To start let’s pick tie line "A" shown. This means that any of the compositions from
points 1 to 3 can be chosen as our top tray vapor compositions.
Close the point f just inside region three as our top tray composition. This composition is
82.665% n-pentane, 12.33% ethanol, and 5.01% water.
The end point compositions of tie line "A" (from Table 1) are:
Thus,
Top Tray Left Phase Right Phase
Pentane 82.756% 0.43% 87.88%
Ethanol 12.326% 23.81% 11.60%
Water 5.018% 75.76% 0.52%
(mole percents)
Step 2: Find the flowrates of the top tray vapor, the reflux, and the distillate (decant).
Since all the water must go out the top of the column, we can use the aqueous phase
composition to determine the distillated flowrates.
DISTILLATE FLOWRATES:
Therefore,
896.643 ∗ .8266 = 741.17 lbmoles / hr. vs. 740.9 + 0.23 = 741.13 lbmoles / hr.
896.643 ∗ .1232 = 10.56 lbmoles / hr. vs. 97.8 + 12.753 = 110.55 lbmoles / hr.
896.643 ∗ .0502 = 45.01 lbmoles / hr. vs. 4.38 + 40.58 = 44.96 lbmoles / hr.
(1) = Water
(2) = Ethanol
(3) = N-Pentane
VENT
CONDENSER
REFLUX
C5 MAKEUP
0.23 lbmoles/hr nC5 DECANT
0.23 lbmoles/hr nC5
12.75 lbmoles/hr Ethanol
COLUMN 40.58 lbmoles/hr Water
FEED
242 lbmoles/hr Ethanol
40.58 lbmoles/hr Water PRODUCT
229.25 lbmoles/hr Ethanol
MASS BALANCE
DYNAMIC MODELLING
OF
Contents
1.0 Introduction
Appendices
References
MNL034 10/01
Page 2 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
1.0 INTRODUCTION
Batch processes are used extensively in the manufacture of relatively small volume products
with relatively high value. These processes are frequently carried out in production facilities
intended for multi-purpose use.
Batch processes are inherently transient in nature and the capability to demonstrate
dynamically the adequacy of the equipment design and performance provides a powerful
design tool. Dynamic modelling can prevent costly mistakes prior to start up. Once a process
model signature has been validated against real plant performance the dynamic model can
be used as a diagnostic tool to identify operating problems.
This paper reviews the basic techniques for dynamic modelling the process and control of
batch reactors and batch distillation systems using the Chemstations integrated range of
software which is supported by an extensive component physical property database and
thermodynamic options.
The power of this database is demonstrated below where the relative merits of the heat
transfer fluids under consideration can be rapid ly presented without wasting design time.
These plots alert the designer to the benefits and disadvantages of the respective fluids
which otherwise could be missed. For example note the difference in liquid specific heats
between water and thermal fluids being a ratio factor varying from 2.8 to 1.8, quite
significant.
MNL034 10/01
Page 3 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The fundamental equation for heat transfer across a surface is given by:
Q = U A ∆Tm
The mean temperature difference ∆ Tm for a batch reactor with contents temperature T
and utility inlet and outlet temperatures t1 and t2 is approximated by:
(t1 + t 2)
∆ Tm = T −
2
The overall heat transfer coefficient U is the sum of individual resistances as follows:
1 1 1 1 1 1
= + + + +
U hi hfi k x ho h fo
The agitated batch reactor inside film coefficient hi is predicted using the Seider-Tate
equation where C, p, and q are constants derived empirically for the agitation system which
are available from manufacturers and is defined as follows:
Nu = C Re0.667 Pr p (ηi ηw )
q
Nu Nusselt number
Re Reynolds number
Pr Prandtl number
η i process side viscosity
η w process side viscosity at the wall
The reactor wall thermal conductivity k when considering glass lined equipment considers
the glass thickness xg and metal wall thickness xm with the appropriate thermal
conductivities for glass kg and metal wall km to give the following expression:
xm + xg
k = where x = xm + x g
xg k g + xm k m
The outside film coefficient ho depends on the type of heat transfer surface design namely
external jacket(s) with or without mixing nozzles, external half coil(s) or internal coil(s).
The film coefficient is a function of the Nu, Re and Pr numbers in the conventional form
with the empirical parameter constants depending on the type of arrangement used.
The inside fouling coefficient hfi and outside fouling coefficient hfo values are determined
by practical experience and there is extensive literature available on this subject. The
combined fouling coefficient hf is given by:
hfi hfo
hf =
hfi + hfo
MNL034 10/01
Page 4 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The Chemstations CCReACS software allows data entry of all the essential thermal design
parameters discussed above. The program will calculate film coefficients dynamically at the
prevailing process conditions or user defined film coefficients may be entered.
A powerful time saving data entry feature allows the user to select the size and type of
reactor to be used in the model and the relevant dimensions will be entered into the input
table automatically. The data entry screens for the reactor are shown below. It can be seen
that these are in Windows format making them very efficient and easy to use.
Stirred batch reactors, with coils or external jackets, exhibit thermal lags due to the heat
capacities of the reactor, reaction mix, jacket contents and jacket services and circulation
system dead time. The utility side film coefficient will become controlling if turbulent
conditions are not established by using an adequate circulation rate together with inlet
mixing nozzles on jackets. The program provides details of the number of mixing nozzles
and the recommended circulation rate.
The thermal conductivity of the reactor materials of construction have a significant effect on
the wall temperatures which can limit cycle times. Extreme temperature differences can
result in product quality problems on certain processes.
The heat removal capability is a function of the resistances to heat transfer, the temperature
difference and the heat transfer area. A thermal runaway (increasing reaction temperature
increases rate of reaction) will occur if the heat cannot be removed fast enough further
accelerated by a reduction in heat transfer area due to a decrease in reactor contents. It may
not always be possible to design for stability where not enough heat transfer area is available
for the design temperature difference. However, stability will be assured if heat is removed
by boiling one or more of the components since this tends to make the system isothermal.
MNL034 10/01
Page 5 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Unimolecular
one molecule decomposes into two or more atoms/molecules → B+C
A→
one molecule isomerizes into a molecule with a different structure →B
A→
Bimolecular
two molecules can associate → AB
A+B→
two molecules can exchange → C+D
A+B→
Arrhenius rate law states that the rate of a chemical reaction increases exponentially with
absolute temperature and is given by
−Ea
k = A exp
R T
The values of Ea and A for any reaction can be determined experimentally by measuring k
the rate of reaction at several temperatures and plotting on logaritmic scales
Ea
ln k = ln A − = ln A − Ea 1
R T
R T
The kinetic data can be entered for single or multiple reactions in the screen shown below:
MNL034 10/01
Page 6 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The heat removal requirement depends on the type of reaction. Vapour pressure systems
with reaction at the reflux temperature are referred to as a tempered reaction system due to
heat removal by latent heat reducing the heat removal requirement for the jacket/coil cooling
system.
Gassy systems generate a permanent gas and require total heat evolved to be absorbed by the
jacket/coil cooling system.
Hybrid systems are a combination of the previous two reaction types and can result in a
significant emission of volatile organic compounds from the overhead condensing system
due to inerts.
The reaction rate (1) depends on the reaction order where a first order reaction conversion
varies with time and a second order reaction conversion varies with square of the reactant
concentrations. First order reactions have the highest rate where the conversion is least
i.e. at time zero.
The reaction rate can be limited by adding the reactant continuously at a controlled rate to
ensure heat of reaction rate does not exceed the heat removal capability of the system.
Some reactions are carried out with all the reactants charged i.e. “all on board”. Their
reactions are frequently carried out at total reflux which enhances the system heat removal
capability.
Predicting the physical properties of the reaction mix during various steps in the process due
to composition and temperature changes can have a significant effect on the reactor
performance.
The presence of non condensables in the condenser results in a significant increase in the
thermal resistance which can result in up to half the heat transfer area being required for the
last zone alone. Chemstations software module CCTHERM allows the modelling of this
process situation.
MNL034 10/01
Page 7 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The conventional control system uses cascade control with the reactor contents temperature
(master/primary) controller output being cascaded to the jacket/coil inlet/outlet temperature
(slave/secondary) controller set point.
This arrangement ensures disturbances in the jacket/coil loop are corrected by the secondary
controller before they can influence the primary controller. The secondary loop thermal time
constant must be less than the primary loop thermal time constant.
The secondary controller is normally a Proportional only controller as Integral Action Time
will slow the response. A proportional band of < 25% is typical. When carrying out boil up
control, where the temperature difference between jacket/coil and reactor contents is set by
by controlling jacket/coil inlet temperature, Integral Action is required to eliminate offset.
The primary controller is normally three mode (Proportional + Integral + Derivative).
The set up screen for the controller is shown below. The controller UnitOp provides the
facility for proving the suitability of a particular control configuration and for optimisation
of the controller settings dynamically.
MNL034 10/01
Page 8 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The selection of a control valve with the appropriate operating characteristics is essential for
satisfactory control loop performance. A valve has two characteristics namely the inherent
characteristic (relationship between flow and stroke at constant ∆P) and the operational
characteristic where the inherent characteristic is modified by the process pressure
conditions. An equal % valve operating characteristic tends towards a linear characteristic as
∆P max/∆P min increases. A linear valve operating characteristic tends towards a quick
opening characteristic as ∆P max/∆P min increases.
Control valve characteristic used is normally equal % though situations may arise where a
linear characteristic provides better control. The operational characteristic of a valve can
also be modified by controller output signal characterisation using various techniques.
Control valve actuators should be pneuma tic with positioners fitted. The calibration for split
range operation of the valves should be achieved at the positioners, not with scaled multiple
controller outputs, to ensure loop integrity is maintained.
There are several methods available for control loop tuning. The Ziegler and Nichols(3) is
commonly used and involves establishing the proportional band at which the process begins
to oscillate at constant amplitude as shown below. Control parameters are then set based on
these values. Refer Appendix III for details of the method.
Condenser Model Period Tu Determination Condenser Model Ziegler Nichols Tuning Method
PB 88% IAT 6.1m Based on Tu of 7.3m
PBu 40% Tu 7.3m
50
40
Temperature(°C)
40
30
Temperature (°C)
30
20 0.122h
20
10
10
0
0
-10
-10
-20
-20
0 0.2 0.4 0.6 0.8 1
0 0.2 0.4 0.6 0.8 1
Time(h)
Time (h)
MNL034 10/01
Page 9 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
These systems involve the connection of the appropriate supply and return services directly
to the reactor jacket/coils. There are many arrangements in use from total manual control to
full automatic control involving forced circulation with steam/water mixing facilities.
Systems are in use providing operating ranges from –20°C to 180°C with ethylene/glycol
mixes, water and steam as services. Ethylene glycol mixes should not be used above their
boiling point.
The scheme below indicates the basic system with automatic control of the steam and
cooling water services. The changeover between heating and cooling modes can be done
manually or automatically involving a complex sequence of valve switching operations
involving time. The changeover is not seamless as with a single fluid system and requires
careful consideration if used on exothermic reactions. The heat up and cool down curves
demonstrate the fast response of these systems which can lead to thermal shock problems
with glass line equipment.
15 10
4 1
11
9
COOLING WATER TC
7 10 5
SUPPLY 4 CONDENSATE
2
7 8 9 6
MNL034 10/01
Page 10 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Ciba Geigy and Wiegand developed a steam jet heater providing a wide range of heating
duties with a single phase in the operating range 5°C to 180°C. This arrangement requires
careful design in relation to air removal/expansion/pressurisation facilities and service
returns from high operating temperatures require special automatic blowdown facilities.
A simplification of this scheme is shown below
14 9
STEAM
9 BARG
12 2 1
8 3
3
CONDENSATE
7 11
8
7
TC
4
COOLING WATER
10 SUPPLY
6
15 5 10 9
6 5
2 COOLING WATER
RETURN
16
These systems provide excellent thermal response due to the elimination of heat transfer lags
associated with heat exchangers. However, to provide combined heating/cooling facilities,
with the exception of the Wiegand system, requires involved automatic valve sequencing
and jacket/coil blowdown routines when changing services resulting in discontinuous
control which can cause serious operational problems when handling exothermic reactions.
Operational problems associated with these systems include cross contamination of services,
corrosion and the need for complex control routines when changing services from heat to
cool involving time lags. These systems are not always cheaper than other alternatives.
MNL034 10/01
Page 11 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
This system is based on the use of a single appropriate heat transfer fluid for the desired
operating range, typically –20°C to 180°C. The circulation rate is set depending on the
number of mixing nozzles and achieving the recommended nozzle pressure drop.
The coolant is directly injected into the reactor jacket/coil circulating loop and a heat
exchanger with steam is provided for heating. Changeover between heating and cooling
modes is seamless using control valves in split range. The heat transfer fluid is on the plate
side of the shell and plate heat exchanger, which provides a high film coefficient. The heat
transfer area is selected based on a reasonable LMTD at approach to service supply
temperature and is sized to ensure that reactor heat transfer is limiting. Equipment in
common use include sealless pumps and gasket free fully welded plate and shell heat
exchangers.
Thermal response on cool is excellent due to direct injection and the use of a three way
valve on the heat exchanger minimises thermal lags on heating. Adopting a three way valve
allows the steam to be applied continuously to the heat exchanger shell at full pressure
which eliminates problems associated with condensate lift/return, prevents freezing when
operating below 0°C and provides excellent linear control characteristics. These systems
require careful consideration to ensure thermal expansion is allowed throughout the loop.
TC TC 2 SYLTHERM XLT
3
-40 C
9 8
7 1 6 12 11
6
2
REACTOR 6.3 m3
10
GLASS LINED
3
SYLTHERM XLT
23000 kg/h 5
5 7
4 SYLTHERM XLT
RETURN
13
MNL034 10/01
Page 12 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The key features of this system are as for the previous system. The use of an additional heat
exchanger for cooling allows the selection of a less expensive fluid for the cooling service
which may provide cost benefits with a centralised refrigeration facility involving the use of
significant volumes of heat transfer fluid.
This system also allows for segregation of the reactor service system from other reactors
which enables rapid identification of water breakthrough problems on a facility with several
reactors.
VENT
EMISSION
18 15
16
U=298.7 W/m2K
10 A= 10.16m2
8
9
20 21
STEAM NITROGEN 13
19 17
14
1
SLAVE MASTER
9
2 TC TC 1
U=1210 W/m2K 11 12 COOLANT
4 A=6.73 m2
5 7 8 11 12
3
6 open @ 20ma 7
close @ 12ma HASTELLOY C
4 10 REACTOR 1.6m3
5
6
open@12ma
close@20ma
3 DOWTHERM J
2 RECIRCULATION 16m3/h
COOLANT
RETURN
1
SLAVE MASTER
12
2 U=447W/m2K TC TC 2
3 9 8
5
A=18.9m2
4 6 8 9 10 1
6
open @ 4ma
closed @ 12ma HASTELLOY C
5 COOLANT REACTOR 1.6m3
11
SUPPLY
4
7
open @12ma
closed @ 4ma
7 DOWTHERM J
3 RECIRCULATION 16m3/h
MNL034 10/01
Page 13 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Dynamic modelling provides the designer and the plant operator with the tools necessary
to study the performance characteristics of a variety of process equipment and control
system configurations. A study of the results from the dynamic models presented verify the
following inherent characteristics
Reactor Parameters
The heat transfer area / reactor volume ratio increases as the reactor size reduces. The use
of oversized reactors should be avoided and can lead to heat removal limitations.
Appendix I provides data for Carbon Steel, Stainless Steel, Hastelloy C and Glass.
The density and specific heats differences are not significant for heat transfer but the
thermal conductivity differences are. Glass lined carbon steel and Hastelloy C are similar
with stainless steel a factor 1.5 higher and carbon steel a factor of 4.7 higher.
Unbaffled jackets result in laminar flow and result in very poor therma l performance
which is enhanced by the use of baffles, dimpled jackets and inlet mixing nozzles.
When using heat transfer fluids that may have high viscosities within the operating
temperature range, mixing nozzle pressure drops may become limiting and ha lf pipe coil
constructions should be considered.
The lags associated with the utility side using thermal fluids are minimised by using forced
circulation and plate heat exchangers for fast response.
For a given set of process conditions the reactor UA is predetermined and it is important
that the external heat exchanger UA does not become limiting at approach temperature
differences. Dynamic modelling confirms the suitability of the design under all conditions.
Heat up
The maximum heat input is achieved when using steam directly on the jacket/coil side,
however this can lead to thermal shock when using glass lined equipment. The changeover
to cooling water based fluid systems requires a control sequence.
Direct steam injected circulating liquid systems avoid the thermal lags associated with
external heat exchangers and hence have superior heat input characteristics. The reduced
heat input associated with single fluid systems can lead to difficulties in achieving required
boil up rates when doing batch distillations. The only variable available to increase boil up
is the jacket/coil temperature which will be limited on water based systems.
Single fluid systems using heat transfer fluids and external heat exchangers have the
lowest heat input capability for a given temperature difference of the systems considered.
The heat input is achieved by increasing the temperature difference at a rate consistent
with thermal shock considerations.
MNL034 10/01
Page 14 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Heat Removal
Heat removal is normally achieved using single fluid liquid systems which will determine
the UA achievable for a given reactor system. The use of partially filled reactors is to be
avoided if possible. The heat removal is therefore determined by the operating temperature
difference which can be enhanced by operating at higher reaction temperatures or under
reflux conditions consistent with reaction kinetics.
The heat removal capability of a facility is limited by the temperature of the utility fluids
available. The heat load on any refrigeration system is to be minimised by cooling using
the higher temperature medium available such as cooling water and then switching to the
lower temperature medium when appropriate.
Heat transfer fluid viscosity effects at low temperatures can become limiting resulting in
low jacket/coil side heat transfer coefficients and high prressure drops. Selection of a heat
transfer fluid with reasonable viscosity characteristics will allow operation down to -90°C.
Boil up Rate
The boil up rates achievable with the various heating systems considered vary between
being excessive with direct steam and being limiting with indirect heat transfer fluid
systems.
The overhead condenser heat duty achievable determines the maximum boil up rate
allowed and the batch distillation process determines the minimum boil up rate to achieve
a satisfactory separation by satisfying the minimum reflux ratio requirements.
To control the boil up and wall temperature, if required, with steam requires pressure
control. To achieve the boil up rates required with single fluid systems the temperature
difference is controlled; the utility heating medium temperature needs to satisfy this
requirement.
Temperature Control
Temperature control of batch reactor systems is inherently difficult due to the thermal lags
associated with the heat transfer process. Appendix III provides a method for establishing
the thermal time constants for the different interfaces. Typical values are shown below for
heating 1000kg toluene in a 1600L Hastelloy C reactor with Dowtherm J fluid.
Reactor contents to reactor wall 15.4 min Reactor wall 3.1 min
Reactor wall to jacket contents 2.6 min Overall 21.7 min
In other words the main contribution is the reactor contents to reactor wall which increases
as reactor size increase. This is further compounded by the decrease in heat transfer area
per reactor volume ratio as the reactor size increases. This emphasises the importance of
correctly matching reactor size to the batch size as using partially filled reactors reduces
the heat transfer area as well as increasing the potential for minimum stir problems.
MNL034 10/01
Page 15 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Batch distillation techniques are used extensively in the Fine Chemicals and Pharmaceutical
Industries to achieve a variety of processing objectives. These include:-
The simplest form of batch distillation involves a single separation stage (represented by the
act of evaporation) which is used where a large difference in volatility exists between the
components to be separated. Such a distillation does not need a fractionating column
between the batch still (normally a stirred jacketed reactor) and the condenser. Simple batch
distillation (sometimes referred to as pot to pot) provides only one theoretical plate of
separation.
When the difference in volatility between the components to be separated is small or when
operating over narrow composition ranges a rectification section is required between the still
and the condenser. Overhead facilities are also required to provide control of reflux ratio and
layer separation when handling heterogeneous azeotropes.
In operation the system is brought to steady state under total reflux which is taken as the
start condition for simulation. Overheads are continuously withdrawn in accordance with the
reflux control strategy. Cuts are taken by switching to different receivers, following a time
or overhead composition strategy, at which point simulation conditions may be changed
whilst starting from the current condition.
The boil up rate achievable with stirred jacketed reactors is dependent upon many factors
associated with heat transfer and has been discussed previously.
The basic techniques are reviewed for process modelling of batch distillations using
Chemstations CC-BATCH simulation package
To establish the number of theoretical stages N required at total reflux to achieve a specified
separation of a binary mixture with near ideal behaviour the Fenske equation is used
.
Nminln α = ln F
XD 1 − XS
Separation factor F =
1 − XD XS
Where X is the mole fraction of the more volatile component and D and S represent distillate
and still compositions respectively.
These relationships can be used to form the basis of establishing performance guarantee
criteria or to establish a performance benchmark based on a given test mixture.
MNL034 10/01
Page 17 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The primary objective in batch distillation is to minimise the batch cycle time by
maximising the heat input and minimising the reflux ratio to achieve the required separation.
The process variables are interdependent as determined by the mass and energy balances and
the mode of operation.
The heat input for a variable top composition achieved by setting a fixed reflux ratio is given
by:-
Q = λ (SO − S1 ) R + 1 ( )
The heat input for a fixed top composition is achieved by varying the reflux ratio to maintain
a fixed top temperature at constant pressure is given by:-
( )
R1
Q = λ (SO − S1 ) ∫ f R d R
RO
Both relationships indicate that the reflux ratio must be kept to a minimum, subject to
satisfying the requirements for the desired separation specification, to optimise the heat
input.
When it has been established that a given column can achieve the requir ed separation at total
reflux it remains to determine the minimum reflux ratio Rmin .
L L R
Reflux ratio R= m= = where m is slope of the operating line
D V (R + 1)
Underwood’s equation for a binary system is given by:-
1 XD α(1 − XD)
R min = −
(α − 1) XS (1 − XS )
When XD is a high degree of purity > 0.995 mole fraction the above can be simplified to:-
1
Rmin =
( α − 1 ) XS
For a high separation factor F a minimum relative volatility of 1.5 is considered reasonable
setting a top limit of Rmin at 2 / XF.
Batch distillations are started with Rmin equal to that required for a continuous split and it
should be noted that Rmin increases as the more volatile component in the still reduces.
The mass balance demonstrates (1) that the top composition is established by the D/V ratio
which is dependant on the reflux ratio.
If the D/V ratio is high, separation will be low, and withdrawal of distillate must be stopped
at a relatively high value of XD, i.e. light ends recovery will be poor.
MNL034 10/01
Page 18 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
If the D/V ratio is reduced to enhance recovery the distillation may consume an uneconomic
amount of time and energy. A mass balance (1, 10) on the MVC yields the following
relationship, known as the Rayleigh equation:-
S0 XS 0 d XS
(dS )X A = d (S XS) ln = ∫
S1 XS 1 XA − XS
The overall mass balance for the system, i.e. still and receiver, yields:-
S0 − S1 = A
S0 XS 0 − A XA A − XS 0 − XA
XS1 = = XS 0 XS1 S1 = S 0
S1 S0 XA − XS1 XS1 − XA
The mass and energy balances demonstrate the interdependence of the process parameters.
Setting one process parameter (specification mode) results in all dependent parameters being
set. The setting of two independent process parameters defines the batch distillation
operational state.
First Specification Mode Second Specification Mode
Reflux ratio Distillate mass rate
Condenser duty Distillate mole rate
Distillate temperature Reboiler duty
Distillate mole fraction Boil- up mole rate
Distillate mass fraction Boil- up mass rate
A sound modelling strategy is to define the still condition by specifying the reboiler duty or
boil up rate which should be adequate to sustain the overhead condition specified, i.e. fixed
or variable composition. As the distillation proceeds, i.e. less MVC in the system, the
reboiler duty requirement will increase to sustain the same boil up rate and to satisfy the
increasing reflux ratio if operating at constant top composition. The following should be
taken into consideration when selecting specification modes.
Distillate temperature (@ constant pressure) sets distillate composition.
For constant boil- up rate reflux ratio sets the distillate withdrawal rate.
Reflux ratio and distillate rate cannot be independently set and neither can reboiler duty and
condenser duty.
MNL034 10/01
Page 19 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
The flow diagram and data entry screens are shown below and are in the easy to use
Windows format. A typical result plot is shown for the distillate composition as the
distillation proceeds. Every parameter is available for plotting to allow detailed investigation
of the process. Adjustment of operational parameters and end step conditions enable an
optimised process to be established readily. Again once a process has been modelled against
actual plant operating conditions dynamic modelling provides a powerful diagnostic tool.
DECANTER
V=L+D D 2
1
V
L 2
R=L/D
1
3
COLUMN
RECEIVERS
STILL 3
MNL034 10/01
Page 20 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Appendix I
Glass thickness can vary between 1 mm and 2 mm. Use 1.5mm(0.06in) thick as a good average.
For steam on the jacket side take an outside film coefficient of 8517 w/m2 K (1500 Btu/ft2 h°F)
For water or other fluid on the jacket side, use the Pfaudler equations or consult the circulating
nozzle leaflets.
Fouling coefficients
Fouling on inner vessel - typical value 5678 w/m2 K (1000 Btu/ ft 2 h°F)
Fouling on jacket side - typical value 5678 w/m2 K (1000 Btu/ ft 2 h°F)
MNL034 10/01
Page 21 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Toluene 59 55 55 55 56 232
Chloroform 60 57 57 57 57 259
Acetone 62 59 59 58 58 284
Reaction Kinetics
MNL034 10/01
Page 22 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Appendix II
When tuning control loops it is important to understand the impact the tuning parameters have on
the process.The minimum effective values are:-
1. Proportional Band
Wide PB (50 – 500%) on fast and noisy processes such as Flow, Liquid Pressure and
Composition.
Narrow PB (1- 50%) on slow processes such as Gas Pressure, Temperature and Vapour
Pressure.
MNL034 10/01
Page 23 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Ziegler and Nichols (3) developed the Ultimate Sensitivity Method which provides a useful
basis for control loop tuning as follows:-
2. Reduce PB whilst making small set point changes (both directions) until the measured
variable begins to oscillate at constant amplitude.
The proportional band PBu and the period Tu are noted.
This procedure can be used as a ‘starting point’ for tuning control systems on batch processes,
Tu being established at a stable condition. Typical periods (T u) for batch reactors vary in the
range 15 to 60 minutes.
Fine tuning involves a trade off between the conflicting requirements of heat up/cool down to
a set point, control of exothermic reactions at a set point, controlling on jacket temperature to
achieve required boil up rates and constraints associated with wall temperature requirements.
MNL034 10/01
Page 24 of 25
Dynamic Modelling of
Batch Reactors and Batch Distillation
Appendix III
(1) (pages75to76)
Reactor Time Constant Estimation
( )
Q = h1 A T − T1 + W1 C1
dT
dt
The thermal time constant for reactor contents to reactor wall is given by
Γ1 =
W1 C1 = W1 C1 (
T − T1 )
h1 A Q
The thermal time constant for reactor outside wall to reactor inside wall is given by
W 2 C2 L
Γ2 = =
W2 C2
(T1 − T2)
k A Q
The thermal time constant for reactor outside wall to jacket contents is given by
W 3 C3 = W3 C3 ( − )
Γ3 = T2 Tc
h3 A Q
The reactor contents time constant based on the overall heat transfer coefficient U is given by
W1 C1
Γo =
U A
A study of the heat up and cool down curves the thermal response can be characterised below
MNL034 10/01
Page 25 of 25
CHEMCAD 6.0 SIZING TOOLS
CONTENTS
Introduction …………………………………............................................................................................................................... 3
APPENDICES
PAGE 2 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
CHEMCAD 6.0 SIZING TOOLS - PIPES, PUMPS, METERS AND VALVES – INTRODUCTION
CHEMCAD simulation software provides tools for the sizing of most types of process plant and equipment. This training note
reviews the shortcut and rigorous sizing facilities available for pipes, pumps, control valves, relief valves and orifice plates. Actual
design cases are presented to demonstrate the power and flexibility of the software, which when used in conjunction with the Excel
mapping tool, provides the designer with powerful facilities.
Short cut methods for Pipes, Control Valves and Orifice Plates are accessed from the main toolbar Sizing command as shown
below:
The stream properties to be used for sizing are selected by a single mouse click on the stream in the model to be studied. In the
example shown below Stream 1, as indicated by the black square markers, has been selected.
Selecting the sizing tool required will make available the relevant data input Window, as shown below, for Pipes, Control Valves and
Orifice Plates:
PAGE 3 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
INTRODUCTION
After data entry, selecting the OK command will provide the calculation results in WordPad or Excel format. When this report is
combined with the Stream properties WordPad report, obtained from “Results - Stream Properties - Select Streams”, a
comprehensive report can be created by editing in Word. The shortcut methods are suitable for use in conceptual design to
establish initial plant sizing and costing. For example, the short cut method for control valves only considers globe valves and the
critical flow and reducer correction factors need to be calculated or determined from specific manufacturers’ data.
For detailed design and specification a more rigorous approach is required involving the use of additional CHEMCAD UnitOps and
manufacturers’ sizing data. The flowsheet below shows the UnitOps for Pipes, Pumps and Control Valves which allow for a more
thorough analysis.
The main Pipe UnitOp data entry Window is shown and allows for the selection of a comprehensive range of sizing methods,
options and friction factors. The Churchill friction factor correlation is valid for the laminar, transition and turbulent flow regimes
whereas Jain is suitable for Reynolds Numbers in the range 4.0 E03 to 1.0 E08. The static head is entered using the elevation
change, where negative values are used for pipes going downwards in the direction of flow.
The Pump UnitOp data entry Window is shown and allows for the selection of a comprehensive range of operating modes, including
multiple speed line performance curves allowing for the study of variable speed applications.
PAGE 4 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
PROCESS DESCRIPTION
This validation case study has been based on the flow of 94% Sulphuric Acid through a 3 in x Schedule 40 carbon steel pipe.
CHEMCAD results are validated against an example given in www.cheresources.com/eqlength.shtml . The process conditions are
shown below:
The pipe section has 2 x 90º elbows, 1 x flow-out branch Tee, 1 x swing check valve, 1 x plug valve, and 1 x 3 in to 1 in expansion.
The contraction has been added to the model for testing purposes.
CHEMCAD MODEL
For practice you can build the model or use the model called “Sulfuric Acid” in the electronic media supplied. It is strongly
recommended that you work with a copy of this job. The model flowsheet is shown that represents the piping layout.
MODEL CONFIGURATION
The key aspect of this problem is the handling of the enlargement and contraction. The fitting must be located in the 1 in pipe
section with separate Pipe UnitOps 1 and 3 included to allow for this. Locating the enlargement and contraction in Pipe UnitOp 3
gives incorrect results. Refer to Appendix I for a detailed assessment of this theory.
The plug valve L/D has been entered as a user value as the CHEMCAD
library value did not match the example data.
The Pipe Section data entry for the 3 in pipe is shown following.
The Curchill friction factor has been selected due to the application
being in the transition flow region.
PAGE 5 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
MODEL CONFIGURATION
DATA MAPPING
The model is controlled directly from an Excel spreadsheet Sulfuric Acid. This is linked to the model using the CHEMCAD Data
Mapping Tool which is accessed from the main Toolbar. The Data Map operation is controlled by the Execution Rules.
The control spreadsheet, located in the My Simulation folder, is selected with Browse. The Data Map is shown in which the desired
Stream or UnitOp is selected, with the required parameter, and assigned an Excel cell in the control spreadsheet.
The execution rules, as set below, transfers input data to CHEMCAD at the start of the simulation and returns results at the end of
the simulation.
The Excel program has a control macro, located and activated from Add Ins, installed which enables the CHEMCAD model to be
linked and controlled from the tool bar using the features shown.
PAGE 6 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
The fitting resistance coefficients used are shown in the table together with CHEMCAD derived Leq values.
Notes
(1) User value fitting coefficient entered into CHEMCAD
(2) The value quoted is calculated using fpipe , if ft is used value is 821.6. Refer to control Excel worksheet for further details.
The spreadsheet studies the handling of the enlargement fitting by different methods. It can be seen that there is agreement
between the different methods with the main issue being whether to use ft or fpipe to calculate Leq.
CHEMCAD predicts a line pressure drop of 12.61 psi as compared to the example line pressure drop of 11.734 using the total
equivalent length method.
CHEMCAD physical property predictions for 94% Sulfuric Acid did not agree with the example values. CHEMCAD has a feature in
the Pipe UnitOp to allow the user to enter different physical properties to the Stream values and this was used.
PAGE 7 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
TOPIC REVIEW
CHEMCAD provides facilities for the sizing of globe type control valves. The methods are based on “Control Valve Sizing” by
th
Masoneilan Company, 6 Edition, which is entirely compatible with ISA SP39.1, “Control Valve Sizing Equations for Incompressible
Fluids”. The fundamental equations are presented as follows:
The valve coefficient (Cv) metric equations for non-viscous liquid flow are given by:
ΔP < Cf (ΔPs )
2
For sub-critical flow where
Gf
C v = 1.16 q
ΔP
3
Where q liquid flow rate (m / h)
Cf critical flow factor from manufacturers’ data
Gf specific gravity of liquid at flowing temperature, water at 15ºC=1.0
∆P actual pressure drop (bar)
ΔP ≥ Cf (ΔPs )
2
For critical flow where 1.16 q Gf ⎛ P v ⎞⎟
Cv = ΔPs = P1 − ⎜⎜ 0.96 − 0.28 Pv
Cf ΔPs ⎝ Pc ⎟⎠
Laminar flow can result at high viscosity or when the valve ∆P or Cv is small.
Calculate turbulent flow Cv and laminar flow Cv and use the larger value as the required Cv.
For laminar flow we have: 0.667
⎛μ q ⎞
C v = 0.032 ⎜⎜ ⎟
⎟
⎝ ΔP ⎠
The control valve characteristic curves are shown below. Generally equal % is used for temperature and flow and linear valves are
used for pressure and level.
PAGE 8 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
CHEMCAD MODEL
The CHEMCAD Control Valve Sizing Liquid model is set up with streams suitably configured for liquids as shown below. A dummy
stream is used to determine liquid vapour pressure. Data Map is defined to interface with the spreadsheet Control Valve Sizing
Liquid located in My Simulation folder.
MODEL CONFIGURATION
The Divider UnitOp 1 allows for transfer of Control Valve calculated flow to Stream 2 to maintain the mass balance around the
Divider. A globe control valve can be sized by selecting Sizing – Control Valve on the main Toolbar. Sizing is to be carried out using
the stream properties of the selected stream. The data entry Window is as follows:
This facility has limited use as it only applies to globe type control valves of sizes ≥ 1 in and the non-critical flow condition.
For a more rigorous design the user should enter manufacturer’s data into the Control Valve data entry screen.
PAGE 9 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
Sizing spreadsheet Control Valve Liquid Sizing has been created to analyse the CHEMCAD model calculation results and to obtain
Physical Property Data to allow for validation of control valve results. Sizing parameters are calculated using the relevant equations.
The sizing spreadsheet for liquid control valve sizing is shown below:
The spreadsheet is configured to facilitate the sizing of most types of control valve under non-critical, critical and laminar flow
conditions. It also allows for the entry of valve characteristic, critical flow factor Fa from manufacturers’ data and for the effect of
reducers.
The spreadsheet allows for the position of Control Valve UnitOp 2 to be adjusted to obtain the Cv at the specified flow conditions.
PAGE 10 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
CHEMCAD 6.0 SIZING TOOLS – CONTROL VALVE GAS AND VAPOUR SIZING TOOL
TOPIC REVIEW
th
The methods are based on “Control Valve Sizing” by Masoneilan Company, 6 Edition, which is entirely compatible with ISA
SP39.3, “Control Valve Sizing Equations for Compressible Fluids”. The fundamental equations are presented as follows:
ρG = M W × Pf × 273 kg 3
/ m
22.415 Z Tf
The valve coefficient (Cv) metric equation for gas and vapour flow at sub-critical and critical conditions is given by:
Q GT
Cv =
(
257 Cf P1 y − 0.148 y
3
)
3
Where Q gas flow rate at 15ºC and 1013 mbar (m / h)
Cf critical flow factor from manufacturers’ data
G specific gravity of gas (air =1.0)
P1 inlet pressure (bar)
T flowing temperature (ºK = 273 + ºC)
CHEMCAD MODEL
The simple CHEMCAD model Control Valve Gas Sizing is set up with streams suitably configured for steam, vapours and gases as
shown below:
PAGE 11 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
Sizing Spreadsheet Control Valve Gas Sizing has been created to analyse the CHEMCAD model calculation results and to obtain
Physical Property Data to allow for validation of control valve results. Sizing parameters are calculated using the relevant equations.
The sizing spreadsheet for Gas and Vapour control valve sizing is shown below:
The spreadsheet is configured to facilitate the sizing of most types of control valve under non-critical and critical flow conditions. It
also allows for the entry of valve characteristic, critical flow factor Fa from manufacturers’ data and for the effect of reducers.
The spreadsheet allows for the position of Control Valve UnitOp 1 to be adjusted to obtain the Cv at the specified flow conditions.
PAGE 12 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
TOPIC REVIEW
CHEMCAD provides facilities for the sizing of concentric orifice plates used in the measurement of fluid flow rates. The methods are
based on “Principles and Practice of Flow Meter Engineering” by L.K.Spink, Foxboro Company, 1967. The fundamental equations
are presented as follows:
Wm
S = 2
N D Fa Fm G f h m
Fa = 1 + 2α (t f − 68 )
Where α coefficient of thermal expansion for orifice material (in/in ºF) see below
typical value for 18/8 SS is 9.5E-06 and for Monel is 7.0E-06
tf flowing temperature (ºF)
Wm
S = 2
N D Fa Fm Fc G f h m
The application of the viscosity correction factor Fc for plant operational measurements and control is rarely justified. Viscosity limits
for 1% calculation tolerance vary in the range of 1 to 8 cps depending on the β ratio, keeping <0.6, and pipe size. Fc can vary in the
range of 1.0 to 1.09. Refer to L.K.Spink Flow Handbook for more information.
PAGE 13 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
TOPIC REVIEW
Wm m w pf
S = 2 νf =
359 D Fa Fm Fc Y νf h m 10.73 T f zf
The sizing procedure is to determine an initial S and then d/D assuming Fc = 1 and Y =1. Then use alignment chart to determine Y
and obtain new d/D from modified S/Y value.
PAGE 14 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
TOPIC REVIEW
If steam is wet the specific weight is adjusted as follows where q is the steam dryness (vapour) fraction:
νf
νfw =
q
If a drain or vent hole (dh) is used to prevent the build up of entrained gas or liquid, the orifice bore is reduced in accordance with the
following relationship:
⎛ 2⎞
⎜ ⎛ dh ⎞ ⎟
da = d ⎜1 − 0.55 ⎜ ⎟ ⎟
⎜⎜ ⎜d ⎟ ⎟⎟
⎝ ⎝ ⎠ ⎠
The orifice sizing data input requires entry of the orifice plate material thermal expansion factor; typical values are shown in the table
below.
Orifice Plate Thermal Expansion Factor Fa
Thermal Expansion Factor
Material
in/in ºF
Carbon Steel 6.7 E-06
Stainless Steel ANSI 304 9.6 E-06
Nickel alloy 13.3 E-06
In sizing metering sections, the pipe should be sized to satisfy reasonable pipe line velocities which are summarised in the
Appendices.
The flow meter differential, hm , is typically set in the range 100 to 200 in wc for liquids and in the range 25 to 50 in wc for gases;
being adjusted to achieve an acceptable β ratio in the range 0.3 to 0.6.
CHEMCAD MODEL
The CHEMCAD model Flow Meter Sizing is set up with streams suitably configured for liquids, steam, vapours and gases as shown
below. Dummy streams are used to determine liquid vapour pressure and steam saturation temperature. Data Maps are defined to
interface with the relevant Worksheet LIQUID, STEAM or VAPOUR of the Flow Meter Sizing spreadsheet.
PAGE 15 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
MODEL CONFIGURATION
An orifice plate is sized by selecting Sizing – Orifice on the main Toolbar. Sizing is carried using the stream properties of the
selected stream. The data entry Window is as follows:
RESULTS
Sizing Spreadsheets have been created to analyse the CHEMCAD model calculation results and to obtain Physical Property Data to
allow validation of orifice sizing results. In all cases agreement was found to be within -0.75% accuracy. Sizing parameters and
thermal expansion factors are calculated using the relevant equations and values for d/D and Y were determined manually from the
appropriate tables in L.K.Spink.
The sizing spreadsheet for Liquid orifice plate sizing is shown below:
PAGE 16 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
The sizing spreadsheet for Steam orifice plate sizing is shown below:
The sizing spreadsheet for Vapour or Gas orifice plate sizing is shown below:
PAGE 17 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
PROCESS DESCRIPTION
This case study develops the design of a cooling water distribution system supplying three shell and tube heat exchangers.
Cooling Water supply is 35000 kg/h at 25ºC and 5 bar pressure. The heat exchanger duties are 50 kW, 100 kW and 150 kW with
cooling water return temperatures all set at 25 ºC. The piping design is to be based on a 3 m/s velocity allowing for upgrade to
75000 kg/h. A restriction orifice, giving a 0.5 bar pressure drop at the flowing conditions, is to be installed in the spillback line.
Control valves are to be sized and used to control heat exchanger cooling water flow to satisfy the design duties.
CHEMCAD MODEL
For practice you can build the model or use the model called “Piping Distribution System” in the electronic media supplied. It is
strongly recommended that you work with a copy of this job. The model flowsheet is shown that represents the piping layout .
MODEL CONFIGURATION
The key aspect of this problem is the handling of the enlargement and contraction. The reducer fitting must be located in the smaller
pipe ie the supply and return equipment headers. The Tees also need careful consideration with the main header UnitOps specified
as Flow Through Run, the equipment supply headers as Flow-out Branch and the return equipment headers as Flow-in Branch.
The restriction orifice plate is sized to achieve a 0.5 bar pressure drop at prevailing conditions.
RESULTS
The control valves are sized initially to achieve a 150 kW maximum duty requiring a Cv of 34. Once sized the control valve is
positioned manually to adjust the flow to achieve the specified duty whilst maintaining a 25ºC outlet temperature. It should be noted
that the model as configured is not achieving a pressure balance at the mixers. This could be achieved by the use of the Node
UnitOp or replacing the Restriction Orifice with a Control Valve to adjust the return pressure.
PAGE 18 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
The piping layout, valves and fittings to be used are shown in the isometric. An orifice plate and control valve is to be installed
downstream of the pump to measure and control flow manually. It is required to determine the branched flow split flow and pressure
drops in the pipe network
Further more the layout is to be tested to ensure an adequate Net Positive Suction Head (NPSH) is available at the pump suction.
The NPSHa is defined as the total pressure available at the pump suction minus the vapour pressure of fluid at pump suction
conditions. If the NPSHa is less than that required by the pump then cavitation will result.
PAGE 19 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
CHEMCAD MODEL
For practice you can build the model or use the model called “Piping Example 3 Build” in the electronic media supplied. It is strongly
recommended that you work with a copy of this job. The model flowsheet is shown that represents the piping layout. This problem is
solved in CHEMCAD using the Pressure Node UnitOp.
MODEL CONFIGURATION
The Pressure Node UnitOp can be considered a calculator that adjusts the network pressure at the node based on the flowrate. In
the network the Node sets the pressure between UnitOps that calculates flow as a function of pressure.
Pipe UnitOps calculate flows based on the Pin and Pout, the Pump and Control Valve UnitOps calculate flows based on the
downstream pressure in the Node; it follows that Node UnitOps located between UnitOps that calculate the flow are set in the “Flow
Set by Upstream and Downstream UnitOps”.
The pressure at the Inlet and Outlet Nodes of this network are fixed at 20 psi and the stream is defined as Free ie not effected by a
UnitOp. The inlet flow could also have been fixed by the Inlet Node.
At a UnitOp there are three variables-Pin, Pout and F; a single equation constrains the system so specification of any two variables
sets the remaining variable.
The Inlet and Outlet Nodes configuration is Fixed Pressure and all other Nodes are Variable Pressure as shown below:
PAGE 20 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
MODEL CONFIGURATION
The pump discharge line size is determined using the CHEMCAD Sizing > Piping facility using a design velocity of 3 m/s. A
discharge line size 0f 3 in was selected and for the suction pipe 4 in, a nominal size larger.
The Pipe UnitOps Method, Sizing Option, Friction Factor and Roughness Factor are configured identically.
The pump discharge stainless steel orifice plate is calculated using the CHEMCAD Sizing > Orifice tool. It is specified with flange
taps, a design differential of 100 in wc and thermal expansion 9.6 E-06 in/in ºF. The unrecovered pressure loss is accounted for by
adding the calculated Kr in the downstream Pipe UnitOp User specified window.
To size the control valve from an initial build, copy the pipe network inlet stream to the control valve inlet stream using Specifications
> Copy Stream Data and change the pressure to 45 psig. Specify valve with a 20 psi pressure drop and a correction factor of 0.95.
In the example shown no allowance has been made for reducers at the pump suction and discharge which are normally required; as
discussed earlier these can have a significant effect and would require additional Pipe UnitOps at the pump inlet and discharge.
PAGE 21 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
The results have been presented in a Graphical User Interface (GUI) format to give a clearer representation. It has been generated
using the CHEMCAD Data Map facility. The graphics and reporting have been done using Excel.
The results are shown for the control valve fully open. It can be seen there is adequate NPSH and the discharge pressure criteria
have been met. The flow split through the heat exchangers, as a result of the piping layout and resistances, is predicted to be 56.1
gpm and 117.1 gpm.
Alternatively a report can be generated using the standard CHEMCAD reporting facilities.
PAGE 22 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
PROCESS DESCRIPTION
This case study investigates the sizing of a relief piping manifold connected to three exothermic reactors; a typical arrangement in a
multiple batch reactor facility. Each reactor has been fitted a 4 in graphite bursting (rupture) disc complete with a vacuum support set
at 2 barg. are shown below:
The relief devices are to be sized for external fire to API 520 standard. To provide a margin of safety the reactors are assumed to be
uninsulated. Reactor 1 is considered to be carrying out an exothermic reaction with a heat evolution of 500 MJ/h.
Refer to paper “Emergency Relief Systems (ERS) Sizing Software Methods and Practice” (P&I Design MNL043A) to decide suitable
Vessel and Vent Flow models, relief device discharge coefficients and F factor for uninsulated vessel.
The key consideration in this application is to ensure that the vent piping manifold does not restrict the vent flow in the event of a
coincident relief. As a general rule sonic flow (ie maximum flow) will be achieved in the relief device if Pin > 0.5xP0ut, where Pout is the
manifold back pressure.
CHEMCAD MODEL
For practice you can build the model or use the model “Relief Vent Piping Manifold” in the electronic media supplied. It is
recommended that you work with a copy of this job.
PAGE 23 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
MODEL CONFIGURATION
The Inlet Nodes are specified in Variable Pressure Mode using current stream rate with the outlet flow being constrained by the
UnitOp. All Nodes in the network use Variable Pressure mode with all Flows set by UnitOp. The Outlet Node is set at a Fixed
Pressure and Free outlet stream. This outlet Node can be used to test the effect of back pressure build up in downstream
equipment.
The Pipe UnitOps specifications windows are all specified as shown; note that Beggs and Brill for two phase flow is required and for
the Nodes to calculate correctly Sizing Option 5 > Given size, Pin and Pout, calculate flow. Pipe size and length are entered to suit.
The relief flows from the individual reactor emergency relief devices are determined using Sizing > Relief Device. The relief stream
to be studied is selected by single mouse click (note black squares at ends of stream). The stream is specified to represent the relief
device inlet at stagnant conditions. The component weight fractions are entered with a nominal flow set at any value, say 1, in units
used. The stream pressure is set at the relief pressure and the vapour fraction set at 0 to give the bubble point of the mixture.
PAGE 24 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
MODEL CONFIGURATION
The Inlet and Outlet piping details are entered. Note that the outlet stream from the relief device is transferred to Stream 4, the
appropriate inlet to the vent piping network.
The relief manifold back pressure is now re-entered as the relief device
back pressure and the sizing re-run until the manifold back pressure
equals relief device back pressure.
RESULTS
The results have been presented in a Graphical User Interface (GUI) format to give a clearer representation. It has been generated
using the CHEMCAD Data Map facility. The graphics and reporting have been done using Excel.
Note that the manifold back pressure is < 0.5 x the set pressures of the relief devices which verifies that the relief venting is not
being reduced by the manifold for a coincident relief scenario.
PAGE 25 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
PROCESS DESCRIPTION
This Case Study investigates a batch reactor temperature control system which uses a jacket recirculation loop as shown in the
schematic below. It was required to determine recirculation sytem pressure drops, size the pump and confirm satisfactory jacket side
heat transfer film coefficients.
BALANCE
HEAT COOLANT
HEATER COOLER
This arrangement requires an adequate recirculation flowrate determined by the reactor size and number of mixing nozzles. The
jacket inlets have mixing nozzles fitted to induce a rotational flow in the jacket and enhance heat transfer. Nozzles should be fitted to
induce circulation in the same direction of rotation. Inadequate flow and / or high viscosity at low temperatures will result in poor heat
transfer and could result in loss of thermal stability when carrying out exothermic reactions.
CHEMCAD does not predict the pressure drop across the mixing nozzles, so the Pfaudler Balfour correlation, shown below, is used.
The pressure drop was calculated in Excel and transferred interactively to the model.
1 C⎛ 0.23 ⎞
⎛G⎞ ⎜ SG μ ⎟
P =⎜ ⎟ ⎜ ⎟
⎝N⎠ ⎜ 0.8A
⎝
⎟
⎠
The case study is based on a Pfaudler Balfour AH 500-LL glass lined reactor with two 1.5” mixing nozzles fitted and a jacket
3
circulation rate of 16 m /h using a nominal pipe size of 2 in.
The jacket operating temperature range was -20ºC to 160ºC and heat transfer fluid Dowtherm J was selected as being suitable.
User component 50% Ethylene Glycol / Water mixture at -20ºC was the coolant available on plant.
PAGE 26 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
PROCESS DESCRIPTION
The viscosity temperature graph, shown below, has been obtained from the Thermophysical - Data Base - Plot Properties facilities
in CHEMCAD.
The jacket side film coefficient is calculated from the following correlations:
D2 D1
2
− 2
E =
D1
Where E equivalent diameter of jacket space for heat transfer
D2 jacket inside diameter (in)
D1 shell outside diameter (in)
39.75 G SG
R =
E μ N DN
0. 5 2
Where DN mixing nozzle diameter (in) and all other symbols as previously noted
For turbulent flow conditions in the jacket, Re > 60, the jacket film coefficient is calculated from:
0.333
433 k R
0.66 ⎛ C pμ ⎞
h = ⎜ ⎟
E ⎜ k ⎟
⎝ ⎠
For laminar flow conditions in the jacket, Re ≤ 60, the jacket film coefficient is calculated from:
0 .333
6 .14 k R
1 .7 ⎛ C pμ ⎞
h = ⎜ ⎟
E ⎜ k ⎟
⎝ ⎠
PAGE 27 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
CHEMCAD FLOWSHEET
For practice you can build the model or use the model called TCMCIRCDOWJ in the electronic media supplied. It is strongly
recommended that you work with a copy of this job. The model flowsheet is shown that represents the piping layout.
MODEL CONFIGURATION
The Pipes Sizing Tool is suitable for an initial assessment of pipe sizing, say for initial estimating purposes, but when progressing to
detailed design the Pipe UnitOp is used. This UnitOp provides extensive sizing methods coupled with the facility to enter elevation
changes, pipe fittings and valves. In this case ball valves are being used and their treatment is discussed in Appendix I.
The inlet stream pressure is set to 1.25 bar being equivalent to the pad pressure of the system; two cases are used to study the
behaviour at minimum and maximum temperatures.
The pump UnitOp is used in its simplest format, being set for pressure increase, which is then adjusted manually until the outlet
stream pressure is equal to 1.25 bar. This mode is acceptable in this configuration but would not be suitable if a recycle was
involved as it would add the specified pressure increase on each iteration. Pump curves can be introduced if required.
The jacket pressure drop is catered for by using the Valve UnitOp. The pressure drop is calculated in Excel using the prevailing
Stream conditions and then transferred to the model using the Data Mapping feature. The heat exchanger pressure drop is entered
into the simplified Heat Exchanger UnitOp.
PAGE 28 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
The control (supervisory) spreadsheet TCMCIRCDOWJ for this job is shown below. The input stream parameter conditions can be
defined here and stream physical property data, as required, is mined from the model for calculation purposes.
This feature provides the designer with very powerful facilities for performing calculations external to the model and testing for their
impact on performance. It also allows the model performance to be validated against established engineering correlations, in other
words provides an independent check.
The model is set up to determine the pressure drop and pump characteristics at the maximum and minimum operating
temperatures.
Initially the design proposed the use of a 50% Ethylene Glycol / Water mixture directly on the jacket. However it was established that
laminar conditions were prevalent on the jacket, resulting in unacceptable nozzle pressure drops and heat removal capabilities. The
use of Dowtherm J provided satisfactory thermal and hydraulic conditions.
The design case for the pump head was at the minimum operating temperature requiring a head of 30.8 m of fluid at a discharge
pressure of 41.8 m wg. The jacket pressure drop was calculated, at minimum temperature, as 1.59 bar; this value was transferred to
the model UnitOp Valve. The design case for NPSH occurred at the maximum operating temperature with 10.53 m fluid being
available.
This model can be used for studying similar systems using any selected heat transfer fluid.
PAGE 29 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
PROCESS DESCRIPTION
This Case Study investigates a flow blending application in which a “wild” flow from a ship offloading facility is blended with an
additive stream of varying composition to achieve a preset blend specification. The basic flow diagram and nomenclature used are
shown below:
DE
E DE + E
VE
DS D S + DE + E
VP
E (
E 1 − VE )
VE = rearranging gives DE =
E + DE VE
E V P DS DE + E 1
VP = E = =
Substituting for DE
E + DE + DS
gives
(−
1 VP VE ) and
DS (V E V P − 1)
We can now determine the Methyl Ester flow required to achieve a specified product blend volume fraction knowing Ship Diesel
Flow and Methyl Ester volume fraction in the Methyl Ester / Diesel mixture. This relationship is used to derive the control system set
point.
DE + E 1
=
DS (V E V P − 1)
which gives the following results
The above relationship allows the process operator to set the final Product blend volume fraction by simply entering the Methyl Ester
blend and final Product blend volume fractions. The control system flow ratio will be derived automatically.
PAGE 30 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
CHEMCAD FLOWSHEET
For practice you can build the model or use the model called BLENDCONTROL in the electronic media supplied. It is strongly
recommended that you work with a copy of this job. The model flowsheet is shown that represents the piping layout.
CONFIGURATION
This model is operated in full dynamic mode. To provide the required operational flexibility the blend pump is provided with a
variable speed motor to control the pressure drop across the blend flow ratio control valve.
The Pump UnitOp 7 is specified by using the manufacturer’s pump curve data using two speed lines as shown below:
The blend ratio between Streams 14 and 15 is controlled at a preset value using Controller UnitOp 14 to adjust Control Valve UnitOp
10 position. The pressure drop across this valve is controlled using Controller UnitOp 19 to adjust Pump UnitOp 7 speed.
PAGE 31 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
RESULTS
The plots in the Excel control sheet calculates the results for 80% and 100% Methyl Ester transfer to T 93 for product blends of 5%,
10% and 15%. The Excel spreadsheet is provided with a “Row Insert” macro which allows CHEMCAD model results, after each
iteration, to be transferred to a new blank row which, in turn, results in a column of data to provide the plots as shown. The
CHEMCAD model is controlled from an Add In function available from CC5 and the macro is controlled from the Start / Reset
Control buttons.
For convenience a Dynamic Model is used to allow for Methyl Ester blend changes to be entered during the run. The spreadsheet
enables the CHEMCAD model results to be validated by independent calculation and helped in the development of a suitable control
strategy.
This flow ratio will be entered into the flow ratio control system which will manipulate the Methyl Ester blend flow control valve to
achieve the desired ratio. In the event that the Methyl Ester blend flow cannot achieve the required ratio the control system will cut
back the Ship Discharge flow control valve. This cut back feature will be achieved by split range valve operation.
The pressure drop across the Methyl Ester flow control valve will be controlled at an operator preset value by manipulating the duty
Methyl Ester blend pump speed. It is anticipated that the optimum pressure drop setting will vary depending on the back pressure
resulting from the transfer line to tank farm storage.
.
3
The CHEMCAD process model predicted Ship Discharge flows in the range 685 to 758 m /h for transfers to T93 and 580 to 653
3
m /h for transfers to T37 indicating that pipe line pressure drops are controlling.
PAGE 32 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
APPENDICES
PAGE 33 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
p =H ρ
p pressure (lb/ft2)
p1 v12 p 2 v 22
+ + z1 = + + z 2 + ∑ hL
w 2g w 2g
Apply Bernoulli's equation for loss at sudden enlargement from small diameter 1 to large diameter 2
2 2
v1 = v 2 +
2g 2g
hL hL =
( v 1
2g
− v 2)
2
hL =
v1
2g
2
(
22
1 − β = K1
v1
2g
) 2
The
final
form is equivalent to Crane equation 3.17.1, to express loss in terms of larger diameter:
2 2
K1 v2 = v2
hL = K2
β
4
2g 2g
(1 − β ) 2vg
2
2
For loss due to sudden contraction hL = 0.5
1
2
For loss at entry to pipe v1
hL = 0.5
For loss at exit from pipe 2 2g
v1
hL =
Refer to Crane 410M A-26 for gradual contractions and enlargements. 2g
PAGE 34 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
The Darcy equation is used to calculate the friction head loss hL (m or ft) of fluid:
2
f L v
hL =
D 2g
f Darcy friction factor, also known as the Darcy-Weisbach or Moody or Blasius friction factor
2
s m
f =m 2 2
=1
m s
In using reference data, care should be taken to ensure the correct friction factor data is being used. Unfortunately, friction factors
are sometimes quoted without definition and incorrect use can lead to significant errors. CHEMCAD Pipe UnitOp uses the Darcy
form throughout.
The Fanning friction factor fF is commonly used in Chemical Engineering and is related to the Darcy friction factor f as follows:
f = 4f F
The from of the Darcy equation using the Fanning friction factor becomes
2f F L v
2 or in the more common form 4f F L v
2
hL = hL =
D g D 2g
64
For laminar flow conditions (Reynolds Number Re < 2300). The Darcy friction factor is given by f =
v Dρ Re
Re =
16 μ
and the Fanning is given by fF = where
Re
The Jain equation is used to solve directly for the Darcy Weisbach friction factor f for a full-flowing circular pipe. It is an
approximation of the implicit Colebrook-White equation.
The equation was found to match the Colebrook-White equation within 1.0% for 10-6 < ε/D < 10-2 and 5000 < Re < 108. However the
Churchill method is applicable for all values of ε/D and Re.
For an independent check of the friction factor the Moody diagram is used. Knowing the pipe flow Re and the pipe roughness
coefficient ε (units of m or ft), giving the relative roughness ε/D (consistent units), the friction factor can be determined. The laminar
flow line formula will allow verification of the diagram friction factor being used. Check friction factor at Re=1000; if Darcy f=0.064
and if Fanning fF=0.016.
PAGE 35 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
2
f L W
ΔP = 0.00000336
ρ d5
∆P Pressure drop ln/in2
W Flow Rate lb/h
3
ρ Fluid Density lb/ft
d Inside Diameter in
In a complex pipe system of pipes and fittings the total head loss is computed from each part using:
2 2
f L v v
hL = ∑ D + ∑K
2g 2g
It should be noted that f is the friction factor of the flowing fluid in the pipe section of diameter D whereas the equivalent lengths of
valves and fittings are related to the fully turbulent friction factor ft giving:
Leq
L K = ft
For the pipe K =f For the fittings D
D
An alternative approach is to determine the K values of the straight lengths of pipe, individual valves and fittings and substitute in the
following:
2
K W
ΔP = 0.00000028
ρ d4
CHEMCAD calculates the equivalent length of fittings using the pipe friction factor and not the friction factor at fully turbulent
conditions. This procedure is acceptable at fully turbulent conditions. However under laminar and transitional flow conditions the
user should check, using the relationships presented here, to ensure acceptable design conditions.
If it is found that the pressure loss is significantly increased through the use of the prevailing friction factor the user can modify the
equivalent length by adding an additional L/D correction in User Specified Fittings and Valve section on the Valve entry screen.
To overcome these problems CHEMCAD includes the facility to use the Darby 3K Method (Chemical Engineer July 1999, April
2001) which is valid over a wide range of Re and fitting size, can be used. Where we have:
⎛ ⎞
K m + ⎜ + Kd ⎟
Kf = Ki ⎜ 1 ⎟
Re ⎜ Din,nom ⎟⎠
0.3
⎝
PAGE 36 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
CHEMCAD library resistance coefficients are derived from the Crane 410M reference.
In CHEMCAD, when handling enlargements and contractions the reducer fitting should be located in the smaller diameter Pipe
UnitOp.
Cd (1 − β )
2
(1 − β )
C = 0 .5 Kr ≈
C β
4 2 4
In CHEMCAD pressure loss due to orifice plates is entered as a User fitting on the valve screen.
Control Valves
For a detailed review of valve sizing issues refer to Emerson Process Management, Fisher Control Valve Handbook, 4th Edition.
However piping installation factors influencing the valve performance are reviewed here.
As a general “rule of thumb” control valves, fitted with full size trims, are usually sized to be less than the line size, typically ½D. This
results in valves being fitted between pipe reducers. Line size valves, fitted with reduced trims, simplify installation but with a
potential increase in cost.
The valve sizing is adjusted by the Piping Geometry Factor, Fp, which for a valve installed between identical reducers, is given by:
−0.5
⎛ 2⎞
⎜
Fp = ⎜ 1 +
∑ K ⎛⎜ C v ⎞⎟ ⎟
⎟ ∑ K = K1 + K 2 = 1.5 1 −β 2( )2
⎜ N 2 ⎜⎜ d 2 ⎟⎟ ⎟
⎝ ⎝ ⎠ ⎠
CHEMCAD allows for entry of Fp correction factor in the control valve sizing calculation procedure.
PAGE 37 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
It should be noted that for ball valves Crane quotes a standard L/D of 3. Manufacturers’ data should be checked to see if this is valid
for size and type of valves being used.
The Resistance Coefficients and L/D can be determined from manufacturers’ Cv data as follows:
L L K
K =f D for full turbulence =
D fT
f = Darcy (Moody) friction factor
fT = Darcy (Moody) friction factor at full turbulence
Tables of equivalent lengths for reduced bore and full bore ball valves
PAGE 38 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
Reasonable Velocities for Flow of Fluids through Pipes (Reference Crane 410M)
Reasonable Velocities Pressure Drop
Service Conditions Fluid
m/s ft/s kPa / m
Boiler Feed Water 2.4 to 4.6 8 to 15
Pump Suction and Drain Water 1.2 to 2.1 4 to 7
General Service Liquids pumped, non viscous 1.0 to 3.0 3.2 to 10 0.05
Heating Short Lines Saturated Steam 0 to 1.7 bar 20 to 30 65 to 100
Process piping Saturated Steam 1.7 and up 30 to 60 100 to 200
Boiler and turbine leads Superheated Steam 14 and up 30 to 100 100 to 325
Process piping Gases and Vapours 15 to 30 50 to 100 0.02% line pressure
Process piping Liquids gravity flow 0.05
Reasonable velocities based on pipe diameter (Process Plant Design, Backhurst Harker p235)
Pump suction line for d in (d/6 + 1.3) ft/s and d mm (d/500 + 0.4) m/s
Pump discharge line for d in (d/3 + 5) ft/s and d mm (d/250 + 1.5) m/s
Steam or gas d in 20d ft/s and d mm 0.24d m/s
Heuristics for process design (Reference W.D.Seader, J.D.Seider and D.R.Lewin, “Process Design Principles”) are also given:
Control valve pressure drop needs to be at a reasonable % of total system pressure drop to provide good control. If too low, ie valve
oversized, the control valve opening will be small leading to unstable control; if too high flow could be limited leading to throughput
concerns. A general “Rule of Thumb” is for a full sized trim control valve to be half the line size.
PAGE 39 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix I
Example Friction factor for cast iron pipe D = 500mm, ε = 0.5 mm (ε/D = 0.001) with Re of 300000 is 0.026
The diagram below shows Colebrook, Churchill, Darcy-Churchill and Blasius friction factors for smooth pipes. The Blasius Equation
being the most accurate for smooth pipes. estimating turbulent pressure drops. Smooth pipe conditions are very well defined.
PAGE 40 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix II
To model piping systems, involving special items such as flow meters, CHEMCAD provides a facility under the Valve Data entry
Window in the Pipe UnitOp for resistance parameters to be entered in various formats. The following guidelines should be
considered when selecting flow meter sizes.
Velocity Limits for Flow of Fluids through Magnetic Flow Meters (Foxboro Bulletin)
Reasonable Velocities Pressure Drop
Service Conditions Fluid
m/s ft/s kPa / m
Liquids pumped, non viscous 0.9 to 4.6 3.0 to 15
General Service Line size meter
Erosive Slurries 0.9 to 4.6 3 to 6
and Process Piping Same ∆P as pipe
Coating forming liquids 1.8 to 4.6 6 to 16
Because of the wide turndown capability of Coriolis flowmeters (30:1 to as high as 200:1), the same flow can be measured by two or
three different sized flow tubes subject to accuracy requirements. Using the smallest possible meter lowers the initial cost and
reduces coating build-up, but increases erosion/corrosion rates and head loss.
Using a meter that is smaller than line size is acceptable if the process fluid is clean with a low viscosity. However on corrosive,
viscous, or abrasive slurry services, this practice may cause reduced operational life. Flow tube sizes and corresponding pressure
drops, inaccuracies, and flow velocities can be obtained from software provided by the manufacturer.
Different Coriolis meter principles incur different pressure drops, but in general they require more than traditional volumetric meters,
which usually operate at less than 10 psi. This higher head loss is due to the reduced tubing diameter and the circuitous path of
flow. Head loss can be of concern if the meter is installed in a low-pressure system, or if there is a potential for cavitation or flashing,
or if the fluid viscosity is very high.
Measurable flow velocities on liquids are in the general range of 0.5 to 9.0 m/s ( 1.5 to 32 ft/s).
74 50
On gas or steam the flow velocities are in the range to 79 m/s ( to 260 ft/s)
ρ ρ
3 3
Where ρ fluid density (kg/m or lb/ft )
Process fluid viscosity requires the Reynolds Number to be greater than 20000
Linear performance is achieved for Reynolds Number in the range 20000 to 7.0 E06
PAGE 41 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix II
For liquids
h
Q = K d2 C
ρf
W = K d2 C h ρ
For gases
2 h pf M
W =K d C
Tf
The diagram below shows the dependency of flow coefficient C on Re and d/D (β).
d/D (β) ratios ≤ 0.6 are preferred. For β> 0.6 viscosity effects are magnified combined with increased sensitivity to upstream piping
configurations.
PAGE 42 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix III
The controller output is used by the control valve to determine the valve position. The control valve algorithm is as follows:
( )
T v du dt + u = A v * P + B v
In the default condition, the time dependent term is equal zero. Time valve constant Tv must be either 0 or positive. The larger this
value is the slower is the valve response to the signal change.
Av = -0.0625 Av = 0.0625
Open Av = -0.125 Av = 0.125 Open Bv = -0.25
Bv = 1.25
V Bv = 1.5 Bv = -1.5 3 Way Valve
V
a Split Range a
l Valves l
v v
e e
Closed Closed
4 12 20 4 12 20
Controller Output (mA) Controller Output (mA)
PAGE 43 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix IV
General Information
Pipe dimensions to ASME B36.1 /API 5L
Plastic Lined Pipe Dimensions
PAGE 44 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix IV
General Information
Table of Roughness Coefficients
For turbulent flow the friction coefficient depends on the Reynolds Number and the roughness of the duct or pipe wall. Relative
roughness for materials are determined by experiments.
Roughness Coefficients ε
Roughness Coefficient ε
Surface
0.001 m ft
Copper, Lead, Brass, Aluminium 0.001 – 0.002 3.33 – 6.7 10-6
PVC and Plastic Pipes 0.0015 – 0.007 0.5 – 2.33 10-5
Stainless Steel 0.015 5 10-5
Commercial Steel Pipe 0.045 – 0.09 1.5 - 3 10-4
Drawn Steel 0.015 5 10-5
Weld Steel 0.045 1.5 10-4
Galvanized Steel 0.15 5 10-4
Rusted Steel(corrosion) 0.15 – 4 5 - 133 10-4
New Cast Iron 0.25 – 0.8 8 - 27 10-4
Worn Cast Iron 0.8 – 1.5 2.7 - 5 10-3
Rusty Cast Iron 1.5 – 2.5 5 – 8.3 10-3
Asphalted Cast Iron 0.01 – 0.015 3.33 - 5 10-5
Smoothed Cement 0.3 1 10-3
Ordinary Concrete 0.3 - 1 1 – 3.33 10-3
Coarse Concrete 0.3 - 5 1 – 16.7 10-3
Well Planed Wood 0.18 – 0.9 6 - 30 10-4
Ordinary Wood 5 16.7 10-3
Darby 3K Coefficient Values (Reference Darby Chemical Engineering April 2001)
−0.5
Swing Check
vmin = 35 ρ 100 1500 0.46 4.0
−0.5
Lift Check
vmin = 40 ρ 600 2000 2.85 3.8
PAGE 45 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix IV
General Information
th
Control Valve Sizing Coefficients (Reference Fisher Handbook 4 Edition)
PAGE 46 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix IV
General Information
Note that the equivalent length of pipe has been declared which requires a friction coefficient at turbulence to be
determined to allow a K value to be calculated; see later.
PAGE 47 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
CHEMCAD 6.0 Sizing Tools – Pipes, Pumps, Meters and Valves
Appendix IV
General Information
PAGE 48 OF 48
MNL 063B Issued 29 August 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
P & I Design Ltd
Process Instrumentation Consultancy & Design
PROCESS MODELLING
SELECTION OF
THERMODYNAMIC METHODS
by
John E. Edwards
jee@pidesign.co.uk
MNL031B 10/08
PAGE 1 OF 38
Process Modelling
Selection of Thermodynamic Methods
Contents
1.0 Introduction
5.0 Summary
Appendices
Figures
PAGE 2 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
References
Acknowledgements
This paper has been developed from experience gained whilst working in the simulation
field. This work has been supported throughout by Chemstations, Houston, Texas, TX77042
www.chemstations.com and the author is particularly indebted to Aaron Herrick and David
Hill for their continued and unstinting help.
PAGE 3 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
1.0 INTRODUCTION
The selection of a suitable thermodynamic model for the prediction of the enthalpy-H and
the phase equilibrium-K is fundamental to process modelling. An inappropriate model
selection will result in convergence problems and erroneous results. Simulations are only
valid when the appropriate thermodynamic model is being used. The selection process is
based on a detailed knowledge of thermodynamics and practical experience. Most
simulators are provided with Wizards to aid selection which should be used with caution.
Equations-of-State (E-o-S)
Activity coefficient (γ)
Empirical
Special system specific
This paper is not intended to be a rigorous analysis of the methods available or in their
selection but is offered as an “aide memoire” to the practicing engineer who is looking for
rapid, realistic results from his process models.
The study of complex systems invariably involves extensive research and considerable
investment in manpower effort by specialists. There are extensive sources of physical
property data available from organisations such as DECHEMA www.dechema.de, DIPPR
www.aiche.org/dippr/ , TÜV NEL Ltd www.ppds.co.uk amongst others.
This paper presents selection methods developed in discussions with engineers in the field.
The validity of the thermodynamic models being used should be tested against known data
whenever possible.
PAGE 4 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
The thermodynamic fundamentals of fluid states in relation to energies and phase behaviour
needs to be thoroughly understood.
Internal Energy U =T S +F
Gibbs Free Energy G =F +P V
Enthalpy H =T S +F +P V
H =U +P V
(
dU = µi − µi dni
0
)
Where dni is change in species i moles
µi is chemical potential species i
dU = T dS − P dV + ∑ µi dni
i
For equilibrium ∑ µi dni = 0
i
PAGE 5 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
The number of intensive variables that can be independently specified for a system at
equilibrium is called the number of degrees of freedom F and is given by the Gibbs Phase
Rule. In a system involving no reactions this is given by:
F = 2 +m −p
Where m = no of chemical species i
p = number of system phases
F = 2 +m −r −p
When defining a stream condition in the model the phase rule applies.
Consider a single component liquid in equilibrium with its vapour and an inert.
Giving m = 2 p = 2 F = 2
Two variables P and T or Vapour fraction (v) with T or P will define the stream.
For a binary liquid system one degree of freedom is consumed by the composition leaving
either P or T to be specified. In a VLE system it is preferable to specify P which then allows
system analysis using Txy plots.
When setting up a Flash UnitOp applying the phase rule will ensure that the relevant flash
conditions are being set. The stream flash calculation can be used to determine the boiling
point and dew point of mixtures with and without inerts present by applying the following:
Note that for a pure component the bubble point and the dew point are identical so a flash
calculation at a vapour fraction of 0 or 1 will yield the same result
Figure 1 shows the Txy diagram for Benzene/Toluene, a near ideal mixture. The bubble
point for a given composition is read directly from the liquid curve and the dew point is read
directly from the vapour curve.
PAGE 6 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
The bubble point of a mixture is determined by trial and error from value of Tbp that
satisfies:
*
P = ∑ xi pi Tbp ( )
The dewpoint of a mixture is determined by trial and error from value of Tdp that satisfies:
yi P
∑ =1
i
( )
p* Tdp
The following table is presented as an “aide memoire” to show the relationships between
volumes, moles, and mass.
Table Presenting Molar and Mass Relationships for Mixture with “i” Species
Volume in Mass in 1 Molar
MW % Mass Flow %
Component 1 m3 m3 % w/w Flow
v/v mol
kg/kmol m3/m3 kg/m3 kg/h kmol/h
PA PAMA 100 P A M A W PA MA W PA
A MA PA VA = PA
100 2241.5 ∑ Pi M i ∑ Pi M i ∑ Pi M i
PB PB MB 100 PB M B W PB M B W PB
B MB PB VB = PB
100 2241.5 ∑ Pi M i ∑ Pi M i ∑ Pi M i
PC PC MC 100 PC MC W PC M C W PC
C MC PC VC = PC
100 2241.5 ∑ Pi M i ∑ Pi M i ∑ Pi M i
Total 100 1
∑ Pi Mi 100 W
100 W
100
2241.5 ∑ Pi M i
Acknowledgements to the late Doug Lindsley for this format.
We have defined: 1 g-mole of any gas occupies 22.415 litre(dm3) at 0ºC and 1 atmosphere.
Therefore we can say that the same g-mole of any gas will occupy the same volume giving:
Mole % = Volume %
__
M
For a Total Flow of W (kg/h) and a mixture density of ρG0 = (kg/m3) we have:
2241.5
__
∑
Volumetric Flow Q =
W 2241.5 W
= (Nm3/h) where average mw M = Pi M i (kg/kmol)
GO ∑ Pi Mi 100
To correcting for temperature and pressure gas density calculations are calculated from:
ρG = M W × Pf × 273 kg 3
/ m
22.415 Zf Tf
where 22.415 is in units of litre(dm3)/g-mole or m3/kg-mole of any gas at NTP(0ºC,1atm),
Mw is molecular weight g/mol or kg/kmol.
PAGE 7 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
2.3 Enthalpy
Enthalpy is the sum of the internal energy (U) and the external free energy (PV) where:
H =U +P V
The heat supplied is given by:
dQ = dU + P dV
The sign convention should be noted and is + for heat added and dU gain in internal energy
dU = Cv dT
dQ = Cp dT
Cp
γ =
Cv
It can be shown that the following relationship holds
Cp − Cv = R
The heating of a liquid at constant pressure e.g. water is considered in Figure 2. This shows
the relationships between the enthalpies in the different phases namely the sensible heat in
the liquid phase, the latent heat of vaporisation during the vapour liquid equilibrium phase
and the superheat in the gas phase.
Enthalpy is calculated using Latent Heat (LATE) in the liquid and vle phases and E-o-S
(SRK) in the superheated or gas phase.
The enthalpy method used will depend on the K-value method selected as detailed in
Appendix II. CHEMCAD forces the following H-values from K-value selected.
Equilibrium-K Enthalpy-H
Peng Robinson (PR) PR
Grayson-Streed-Choa-Seeder(GS) Lee Kessler (LK)
ESSO LK
Benedict-Webb-Rubin-Starling (BWRS) BWRS
AMINE AMINE
PAGE 8 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
∆G = ∆H − T ∆S
The values for ∆H are determined from the heats of formation of the components and for ∆S
from thermodynamic property tables. Superscript 0 indicates materials present in standard
state at 298ºK.
For isothermal processes at low temperature the ∆H term is dominant. At absolute zero ∆S
and T are zero so ∆G = ∆H. The relationship shows ∆S becoming of increasing importance
as the temperature increases.
Adsorption Processes
Evaporation Processes
When a liquid boils the vapour pressure is equal to the atmospheric pressure and the vapour
is in equilibrium with the liquid. If there is no superheat the process is reversible and ∆G = 0
and the entropy change can be calculated:
∆H vaporisation
∆S =
TB
Entropies of vaporisation, at these conditions, have values near 88 J/molºK, and substitution
in the above gives Trouton’s rule. However in the case of water, due to significant hydrogen
bonding, the entropy change on evaporation is larger at 108.8 J/molºK.
The link between Gibbs free energy and the reaction equilibrium constant K is represented
by the equation
∆G = -RT log K
A reaction will proceed provided ∆G is negative. The reaction temperature can alter the sign
and therefore the process feasibility.
Chemical Equilibrium
For a reaction at equilibrium (all reactions can be considered equilibrium since no reaction
goes to completion) there is no net reaction in either direction and we have:
∆G = 0
In CHEMCAD the Gibbs reactor is based on the principal that at chemical equilibrium the
total Gibbs free energy of the system is at its minimum value. The Gibbs reactor can be used
in the study of combustion processes including adjustment of air to fuel ratios and
calculation of the heats of reaction.
PAGE 9 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
There are three phase states namely solid, liquid and gas. Processes comprise either single
phase or multiphase systems with separation processes involving at least two phases.
Processes involving solids such as filtration and crystallisation, solid – liquid systems and
drying, solid – gas system are special cases and receive no further consideration here.
The primary area of interest for thermodynamic model selection involve two phases.
Liquid – liquid systems, such as extraction and extractive distillation, where liquid – liquid
equilibrium (LLE) is considered and vapour liquid systems, such as distillation, stripping
and absorption, where vapour – liquid equilibrium (VLE) is considered.
Figure 3 shows the inter-relationships between the system phases for a series of isotherms
based on the Equation of State (E-o-S) due to van-der-Waal. This figure provides the first
indication of the validity of making a thermodynamic model selection for the K-value on the
basis of the system phases namely single phase gas by E-o-S and VLE by activity
coefficient.
An E-o-S relates the quantity and volume of gas to the temperature and pressure.
P V =n R T
In an ideal gas mixture the individual components and the mixture as a whole behave in an
ideal manner which yields for component i the following relationships
P i V = ni R T
pi ni
= = yi where yi is mole fraction of i in gas
P n
pi = y i P
∑ pi = P where P is the total system pressure
i
µi = µi + R T ln pi
0
As the system temperature decreases and the pressure increases deviations from the ideal gas
E-o-S result. There are many equation of state(3) available for predicting non-ideal gas
behaviour and another method incorporates a compressibility factor into the ideal gas law.
PAGE 10 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
To predict the behaviour of real gases the concept of fugacity f is introduced giving:
µi = µi + R T ln f i
0
P V B (T ) C (T )
=1 + + + 2
R T V V
Where B(T) is the second virial coefficient
C(T) is the third virial coefficient
Note if B = C = 0 the equation reduces to the ideal gas law.
This E-o-S is in the same form as the above equation extended to a fifth virial coefficient.
BWR is accurate for gases containing a single species or a gas mixture with a dominant
component e.g. natural gas, and provides considerable precision.
This represents an E-o-S linear in pressure and cubic in volume and is equivalent to the
virial equation truncated at the third virial coefficient.
One of the first E-o-S was that due to van der Waals (University of Leiden), developed in
1873, which is shown in Figure 4. This was based on two effects
1. The volume of the molecules reduces the amount of free volume in the fluid, (V-b)
2. Molecular attraction produces additional pressure. The fluid pressure is corrected
by a term related to the attraction parameter a of the molecules, (P+a/V2)
PAGE 11 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
The most widely used cubic E-o-S is the Soave modifications of the Redlich-Kwong (SRK)
equation which is a modification to van der Waals original equation.
R T α a
P = −
(V − b ) V (V + b )
Where α, a and b are system parameters. Parameters a and b are determined from the
critical temperature Tc and critical Pressure Pc. Parameter α is determined from a correlation
based on experimental data which uses a constant called the Pitzer Accentric Factor(3).
At the critical point the two phases (gas and liquid) have exactly the same density
(technically one phase). If T > Tc no phase change occurs. Refer to Figure 2.
The Compressibility Factor E-o-S retains the simplicity of the ideal gas law but is
applicable over a much wider range of conditions.
The compressibility factor, dependent on the gas temperature and pressure, varies for
different gases and is determined from reference data(5).
If data is not available for the specific gas generalised compressibility charts can be used
which require the critical temperature and critical pressure of the gas
For single phase gas systems the following guidelines for thermodynamic model selection
are proposed:
PAGE 12 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
On systems involving liquid phases the thermodynamic K-value selection is driven by the
nature of the solution. Appendix II provides a summary of thermodynamic selection criteria
considered in this section.
Ideal solution
These solutions are non-polar and typically involve hydrocarbons in the same homologous
series.
These solutions exhibit mildly non ideal behaviour and are usually non-polar in nature.
These exhibit highly non-ideal behaviour and will use activity coefficient or special K-value
models.
Binary interaction parameters (BIPs) are required by both methods for accurate modelling.
Special
In non-polar applications, such as hydrocarbon processing and refining, due to the complex
nature of the mixtures and the large number of species pseudo components are created based
on average boiling point, specific gravity and molecular weight. The alternative is to specify
all species by molecular formula i.e. real components.
PAGE 13 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Ideal Solutions(3)
µi = µi + R T ln (xi )
0
If an ideal solution is considered in equilibrium with a perfect gas the phase rule
demonstrates that the two phases at a given T and P are not independent.
Raoult’s Law describes the distribution of species i between the gas and the liquid phases
p i = y i P = xi p i
0
at temperature T
Raoult’s Law is valid when xi is close to 1 as in the case of a single component liquid and
over the entire composition range for mixtures with components of similar molecular
structure, size and chemical nature.
The members of homologous series tend to form ideal mixtures in which the activity
coefficient γ is close to 1 throughout the concentration range.
The following systems can be considered suitable for Raoult’s Law.
1 Aliphatic hydrocarbons
2 Aromatic hydrocarbons
benzene (C6H6) toluene (C6H5•CH3)
For ideal liquid systems the following guidelines for thermodynamic model selection are
proposed
Equilibrium-K Enthalpy-H
Ideal Vapour Pressure(VAP) SRK
p i = y i P = xi H i at temperature T
Henry’s law constants Hi for species i in given solvents are available. Typical applications
include slightly soluble gases in aqueous systems. Refer Appendix IV for further details.
PAGE 14 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Non-ideal solutions(3)
In a non ideal solution the chemical potential μi for species i is of the form:-
µi = µi + R T ln (γ i xi )
0
Consider a non-ideal solution in equilibrium with a perfect gas we can derive an equation of
the form:
p i = k i γ i xi
p
Raoult’s law when γi→1 and xi→1 k i = p0i giving γ i = 0 i = 1
p i xi
Henry’s law when γi→1 and xi→ 0 giving k i = Hi
The fugacity of component i in the liquid phase is related to the composition of that phase
by the activity coefficient γ as follows:
a f
γ i = i = li 0
xi xi f i
0
The standard state fugacity f i is at some arbitrarily chosen P and T and in non-electrolyte
systems is the fugacity of the pure component at system T and P.
Regular solutions
Regular solutions exhibit mildly non-ideal behaviour and occur in non-polar systems where
the component molecular size, structure and chemical nature do not differ greatly. These
systems can be modelled using an E-o-S.
K-values are calculated from the following relationships using fugacity coefficients
y i φli
Ki = = where fugacity coefficients φ vi = f vi and φli = f li
xi φ vi P xi P
PAGE 15 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
These are systems where the liquid phase non-idealities arise predominantly from molecular
associations. These systems must be modelled using activity coefficient methods which will
require binary interaction parameters for accuracy.
Models covered by the activity coefficient method include NRTL, UNIQUAC, Wilson,
UNIFAC, HRNM, Van Laar, Margules and GMAC.
PAGE 16 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
VLE diagrams provide a very useful source of information in relation to the suitability of
the K-value selected and the problems presented for the proposed separation. Having
selected a K-value method test the TPxy and VLE diagrams against known data for the
pure components and azeotropes if present.
Figure 5 in the attachments shows the VLE diagrams for N-Hexane systems.
p1 = γ1 x1 p1 p2 = γ 2 x2 p2
0 0
and
γ1 p1 γ1
0
Since γ > 1 is the usual situation, except in molecules of a very different size, the actual
relative volatility is very often much less than the ideal relative volatility particularly at the
column top.
Values of γ can be calculated throughout the concentration range using van Laar’s equation
2
1
γ =
ln 1 A12 where A12 = ln γ1∞ with ∞ representing infinite dilution
1 + A12 x1
A 21 x2
An extensive data bank providing values of parameter Axy are available from DECHEMA.
Values of γ can also be calculated at an azeotrope which can be very useful due to the
extensive azeotropic data available in the literature.
P
At an azeotrope we have x1 = y1 giving y1 P = x1 γ1 p10 resulting in γ1 = 0
p1
Figure 6 in the attachments shows the VLE diagrams for N-Hexane(1)/Ethyl Acetate(2)
system. CHEMCAD Wizard selected K-value NRTL and H Latent Heat and it can be seen
that the model is reasonably accurate against known data. The γ values are shown and their
influence seen at the column bottom and top.
Figure 7 in the attachments shows the VLE diagrams for Ethanol(1)/Water(2) using K-value
method NRTL and SRK which clearly demonstrates the importance of model selection. To
achieve convergence for high purity near the azeotropic composition it is recommended to
start the simulation with “slack” parameters which can be loaded as initial column profile
(set flag) and then tighten the specification iteratively.
PAGE 17 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Uni-molecular
One molecule decomposes into two or more atoms/molecules A→B+C
One molecule isomerizes into a molecule with a different structure A→B
Bimolecular
Two molecules can associate A+B→AB
Two molecules can exchange A+B→C+D
The reaction rate(9) depends on the reaction order. First order reaction conversion varies with
time and second order reaction conversion varies with square of the reactant concentrations.
First order reactions have the highest rate where the conversion is least, i.e. time zero.
The kinetics of a reaction is determined from the Arrhenius rate law which states that the
rate of a chemical reaction increases exponentially with absolute temperature and is given
by:
− Ea
k = A exp
R T
where R = universal gas constant = 8.314 J / °K mol
Ea = activation energy J / mol
A = frequency factor or pre-exponential factor consistent units
The values of Ea and A for a reaction can be determined experimentally by measuring the
rate of reaction k at several temperatures and plotting ln k vs 1/T. Applying ln we have:
Ea 1
ln k = ln A −
T
R
Ea is determined from the slope Ea/R and A from ln A the intercept of 1/T.
In many applications the reaction kinetics will not be known. In these cases the overall heat
of reaction ∆Hr and frequency factor f are required to establish reactor thermal design and
stability. If the heat of reaction is not known it can be estimated from the standard heats of
formation, ∆Hf0 (5), the stoichiometric coefficients νi of the reactant and product species i
involved, using Hess’s Law(2, page 428) as follows:
∆H r = ( )
∑ ν i ∆Hf0 i −
Pr oducts
(
∑ ν i ∆Hf0 i
Re ac tan ts
)
In applying Hess’s Law it is important to correctly apply the heats of formation for the
reaction phases involved.
Appendix I reviews the CHEMCAD handling of the enthalpy of reactions in some detail.
PAGE 18 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
The activation energy Ea cannot be derived logically from the heat of reaction ∆Hr but can
be estimated using a thermodynamics analogy(10, pages 21-34), where we have:
The Polanyi-Semenov equation can also be used: Ea = C – α (-∆Hr), α and C are constants.
For exothermic reactions α = -0.25 and C = 48 kJ/mol
For endothermic reactions α = -0.75 and C = 48 kJ/mol.
The values can vary with reaction type (12, 13)and should be validated from reference sources.
The units for Ea and A are used in various forms so caution is required in their use. Ea is
usually in the form energy/(mol reactant species) and A in mol/s referenced to reactant
volume, depending on the units of k.
In a reaction, where the total moles of reactant Nr is converted in reaction time θ, the
conversion rate r given by:
N r mol/s
r =
θ
Total heat of reaction H is given by: H = N r ∆H r
The frequency factor f in units of mol/m3s is derived from the reactant mix volume Vr
r
f = mol/m3s
Vr
The mean heat output from the reaction is given by: Q r = r ∆H r
For exothermic reactions to be carried out safely, the heat removal capability Q of the
reaction system must exceed the maximum predicted heat output Qr by an acceptable
margin. A thermal runaway (increasing reaction temperature increases rate of reaction) will
occur if the heat cannot be removed fast enough, further accelerated by a reduction in heat
transfer area due to a decrease in reactor contents.
It may not always be possible to design for stability where not enough heat transfer area is
available for the design temperature difference. However, stability will be assured if heat is
removed by boiling one or more of the components since this tends to make the system
isothermal. For a system U and design set ∆Tm there is an equilibrium heat transfer area
where heat removal capability equals reaction heat output. This consideration determines an
acceptable reactor size to ensure adequate heat transfer area under all reaction conditions.
PAGE 19 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
5.0 SUMMARY
If inadequate BIP data is available for the activity coefficient method the Wizard defaults to
UNIFAC. The key decision paths in the method are shown in Figure 8 in the attachments.
When using the Wizard, initially exclude utility streams from the component list as the
presence of water for example will probably lead to an incorrect selection.
The following additional points should to be considered when setting the K-Value
Vapour phase association typical systems acetic acid, formic acid, acrylic acid
Vapour fugacity correction set when using an activity coefficient method P > 1bar
PAGE 20 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix I
CHEMCAD calculates the stream enthalpy beginning at the ideal gas heat of formation referenced
at 25°C, 1 atm, gas [A], subtracts the heat of vaporization at 25°C and 1 atm [HoV] to give the ideal
liquid heat of formation at 25°C, 1 atm, liquid [B]. Using Cp liquid, the liquid enthalpy from 25°C
to the desired temperature is calculated. This temperature can be the stream temperature and if the
stream is a liquid the enthalpy calculation is complete.
If the stream is vapor, the calculation of liquid enthalpy continues until the boiling point at Tb [C]
and the heat of vaporization at this temperature [HoV] is added to come to the gas state [D]. From
here Cp ideal gas is used to come to the stream temperature [C], if this is higher than the boiling
point as shown in the diagram.
Using the liquid heat of formation as a starting point, instead of the gas heat of formation, gives the
advantage that the pressure has no influence on Cp liquid. If the stream is liquid this gives the
optimum solution. If the stream is a gas, there will still be a small problem if the stream pressure is
high, because Cp gas is measured for ideal gas only and there is no pressure correction available.
PAGE 21 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix I
CHEMCAD begins in that case with the ideal gas heat of formation. This has the advantage for the
gas phase that the pressure is part of the enthalpy.
The gas models are SRK, PR, Lee Kessler, BWRS and others. In the liquid phase these models are
not as good as the Cp liquid calculation using the latent heat model. In the case the liquid is highly
non-ideal the user should select the Latent Heat model and not an Equation of State for the enthalpy
calculation. This is the reason why the thermodynamic Wizard selects NRTL, or UNIQUAC or
UNIFAC together only with Latent Heat as the best enthalpy model
Calculating the stream enthalpy at 25°C, 1 atm which means the user goes from A to B to C to D to
A. this should give the ideal gas heat of formation at 25°C, 1 atm. Theoretically the thermodynamic
rules says that, but because of errors in the measured physical properties, which are used here, there
will be a small deviation in comparison to the data of the databank if the model is latent heat.
PAGE 22 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix I
Enthalpy of Reactions
The calculation of enthalpy in CHEMCAD reactors is now discussed. Consider the following gas
phase reaction to check the enthalpy balance. Refer Job File EREA2.
Stream No. 1 2
Temp C 25.0000* 25.0000
Pres bar 1.0000* 1.0000
Enth MJ/h 52.256 -83.906
Enthalpy balance (Str2 – Str1) -83.9 - 52.2 = -136.1 MJ/h
Vapor mole fraction 1.0000 1.0000
Total kmol/h 2.0000 1.0000
Total kg/h 30.0698 30.0700
Total std L m3/h 0.1091 0.0845
Total std V m3/h 44.83 22.41
Hydrogen kmol/h 1.0000 0.0000
Ethylene kmol/h 1.0000 0.0000
Ethane kmol/h 0.0000 1.0000
Equip. No. 1
No of Reactions 1 Specify reaction phase 1
Specify thermal mode: 2 C 25.0000 MJ/h -136.1326
Temperature Units: 3 Pressure Units: 4
Heat of Reaction Units: 4 Molar Flow Units: 1
Edit Reaction No. 1
Calc Overall Ht of Rx -136.1330 (MJ/h)
Reaction Stoichiometrics and Parameters
Reaction no. 1 Base component 1
Frac.conversion 1.0000
1 -1.0000 2 -1.0000 3 1.0000
The heat of reaction is -136.13 MJ/h, and the heat duty is also -136.13 MJ/h.
The flowrate of 1 kmol/h gives a heat of reaction of -136.13 kJ/kmol. This result can be checked
using the heat of formation in the databank.
PAGE 23 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix I
Enthalpy of Reactions(Cont)
Consider the following vapor phase reaction at 120°C. We can ignore the heat of condensation.
Refer Job File: EREA3
2H2 + O2 = 2 H2O at 120°C
Stream No. 1 2
Stream Name
Temp C 120.0000* 120.0000
Pres bar 1.0000* 1.0000
Enth MJ/h 8.2364 -477.95
Enthalpy balance gives heat duty: Str2 – Str1 = -477.9 -8.2 = -486.1 MJ/h
Vapor mole fraction 1.0000 1.0000
Total kmol/h 3.0000 2.0000
Total kg/h 36.0306 36.0300
Total std L m3/h 0.0861 0.0361
Total std V m3/h 67.24 44.83
Hydrogen kmol/h 2.0000 0.0000
Oxygen kmol/h 1.0000 0.0000
Water kmol/h 0.0000 2.0000
Equip. No. 1
No of Reactions 1 Specify reaction phase 1
Specify thermal mode: 2 C 120.0000 MJ/h -483.2837
Temperature Units: 3 Pressure Units: 4
Heat of Reaction Units: 4 Molar Flow Units: 1
Edit Reaction No. 1
Calc Overall Ht of Rx -483.6400 (MJ/h)
Reaction Stoichiometrics and Parameters for unit no. 1
Reaction no. 1 Base component 1
Frac.conversion 1.0000
1 -2.0000 2 -1.0000 3 2.0000
The heat of reaction is -483.64 MJ/h. The heat duty of the reactor is ∆H = -483.28 MJ/h. There is a
small difference between the reactor heat duty and the heat duty calculated as the enthalpy
difference of the two streams calculated manually.
PAGE 24 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix I
Enthalpy of Reactions(Cont)
Consider the following reaction in which the product stream is liquid. Refer Job File: EREA3
2 H2 + O2 = 2 H2O at 25°C
Stream No. 1 2
Temp C 25.0000* 25.0000
Pres bar 1.0000* 1.0000
Enth MJ/h -0.00459418 -572.04
Enthalpy balance gives heat duty: Str2 – Str1 = -572.0 MJ/h
Vapor mole fraction 1.0000 0.00000
Total kmol/h 3.0000 2.0000
Total kg/h 36.0306 36.0300
Total std L m3/h 0.0861 0.0361
Total std V m3/h 67.24 44.83
Hydrogen kmol/h 2.0000 0.0000
Oxygen kmol/h 1.0000 0.0000
Water kmol/h 0.0000 2.0000
Water is under 25°C liquid, so the enthalpy of condensation must be included. The heat of
condensation ≈ 40.6 MJ/kmol at 1 bar.
Equip. No. 1
No of Reactions 1 Specify reaction phase 1
Specify thermal mode: 2 C 25.0000 MJ/h -569.1345
Temperature Units: 3 Pressure Units: 4
Heat of Reaction Units: 4 Molar Flow Units: 1
Edit Reaction No. 1
Calc Overall Ht of Rx -483.6400 MJ/h
Reaction Stoichiometrics and Parameters for unit no. 1
Reaction no. 1 Base component 1
Frac.conversion 1.0000
1 -2.0000 2 -1.0000 3 2.0000
The reaction enthalpy balance at 25°C, under ideal gas conditions, gives -483.6 MJ/h, being equal
to the ideal gas heat of reaction as before. Because the heat of condensation is included the heat
duty is now -569.1 MJ/h, which is close to the enthalpy difference of the output and input streams
(572 MJ/h).
PAGE 25 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix I
Enthalpy of Reactions(Cont)
There may be a small discrepancy between the manual calculation of heat duty, which is the
enthalpy difference between the output and input streams and the heat duty calculated by the
reactor. This is because the reactor calculates the heat duty differently. Under the rules of
thermodynamics there should never be any difference between enthalpy calculations because the
method has no influence on the result as long as the initial and final conditions are identical. To
understand the enthalpy calculation which the reactor uses the following graphic shows the manual
calculation of the heat duty for the reactor.
The reactor calculates the heat duty assuming the input and output streams are gas.
1. Adjust the input composition, temperature and pressure (A) to 25°C gas and 1 atm (B),
being the conditions of the ideal gas heat of formation.
2. Add the heat of reaction at 25°C at 1 atm (R)
3. Modify output composition from 25°C and 1 atm to output temperature and pressure (C).
So we go from Initial state A to Final state C via B and R. The heat duty result is C - A. In this case
the output stream vaporized so CHEMCAD has to calculate the heat of vaporization as shown.
PAGE 26 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix II
Thermodynamic Model Synopsis – Vapor Liquid Equilibrium
The primary consideration when selecting a thermodynamic model is to consider the liquid phase.
Liquid solutions are defined from five categories:
1 Ideal Solutions are systems where the vapor phase behaves essentially as an ideal gas.
Pressure will be low (<1bar), all the molecules in the liquid phase virtually the same size and
no intermolecular forces exist.
VAP model for K-value and SRK for enthalpy are proposed. Vapor-liquid equilibrium is
according to Raoult's law:
0
y i pi
Ki = = where p0i is pure component vapour pressure
xi P
2 Regular Solutions are systems where the non-idealities stem from moderate physical
interactions due to the differences in the size and shape of the molecules with minimal
intermolecular associations. The vapor and the liquid phases are assumed to form regular
solutions that are mildly non-ideal. The following table should be considered:
K-values are calculated from the following relationships by applying fugacity coefficients
y i φli
Ki = = where fugacity coefficients φ vi = f vi and φli = f li
xi φ vi P xi P
3 Polar Non-electrolyte solutions are systems where the liquid phase non-idealities arise
predominantly from molecular associations. These systems must be modelled using activity
coefficient methods, which generally require BIPs for improved accuracy.
The vapor phase is taken to be a regular solution giving:
y i φli γ i f 0li
Ki = = = where
xi φ vi φ vi P
0
f li standard fugacity comp i, φ vi fugacity coeff. vapour comp i, γ i activity coeff. liquid comp i.
Models covered by activity coefficient methods include NRTL, UNIFAC, UNIQUAC, Wilson,
T.K.Wilson, Van Laar, Margules and GMAC. Use Wilson, NRTL, and UNIQUAC when
sufficient data is available (>50%) and UNIFAC when data is incomplete (<50%)
5 Special Systems are provided for the simulation of application specific processes.
Henry’s Law, see Appendix IV. K-Amine and H-Amine model is of topical interest due to its
application to the study of post combustion carbon capture systems. See Appendix VI.
PAGE 27 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix III
HYDROCARBONS
K-VALUE METHOD APPLICATION H-ENTHALPY
Soave-Redlich-Kwong Pressure >1bar
SRK
(SRK) (1) General hydrocarbon
Pressure >1bar
API SRK(1) SRK
General hydrocarbon
Pressure >10 bar
Peng-Robinson (PR)(1) PR
Cryogenics < -70ºC
Benedict-Webb-Ruben-Starling Pressure>1bar
BWRS
(BWRS) (1) Single species
Moderate P >7bar <200bar
Grayson-Streed (GS) (1) Temperature –18C to 430C Lee-Kessler (LK)
Heavy end hydrocarbons
Pressure < 7bar
ESSO(3) Temperature 90 - 200ºC Lee-Kessler (LK)
Heavy end hydrocarbons
Hydrocarbon –water
Elliott, Suresh, Donohue (ESD)(1) SRK
Hydrocarbon-gases
Hydrocarbon –water
SAFT(1) SRK
Hydrocarbon-gases
(1)
Modified SRK (MSRK) Halogenated aliphatics SRK
CHEMICALS
K-VALUE METHOD APPLICATION H-ENTHALPY
Vapor Pressure (VAP)(3) Ideal solutions SRK
P (0-4atm) T (275-475ºK)
Non-ideal - two liquid phases
UNIFAC(2) LATE
Heterogeneous azeotrope
Group Contribution Predictive
Non-ideal solution with dissolved solids
Wilson(2) LATE
Homogeneous azeotrope
Highly non-ideal - two liquid phases
NRTL(2) LATE
Heterogeneous azeotrope
Highly non-ideal - two liquid phases
UNIQUAC(2) LATE
Heterogeneous azeotrope
Highly non-ideal - two liquid phases
Margules(2) LATE
Homogeneous azeotrope
Highly non-ideal - two liquid phases
T.K.Wilson(2) LATE
Homogeneous azeotrope
Hiranuma (HRNM)(2) Highly non-ideal - two liquid phases LATE
Regular Solution(2) Moderately non-ideal (Predictive) SRK
Moderately non-ideal
Van Laar(2) LATE
Homogeneous azeotrope
Modified SRK (MSRK)(1)
Polar compounds in regular solutions SRK
4 parameter
Polar compounds in non-ideal solutions
Predictive SRK (PSRK)(1) LATE
Better than UNIFAC at high pressures
PAGE 28 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix III
SPECIAL MODELS
K-VALUE METHOD APPLICATION H-ENTHALPY
Henry’s Gas Law(3) Gases dissolved in water LATE
Gas sweetening H2S-MEA-DEA
Amine (AMINE) Amine
Carbon capture CO2 absorption
Sour Water (SOUR) H2S-CO2- NH3 dissolved in H2O SRK
(1) Methanol systems with light gases
Extended SRK (TSRK) SRK
and/or water
Ionic compounds which dissolve in
Partial Pressures of Aqueous
water and disassociate e.g. HCl, NH3, SRK or LATE
Mixtures (PPAQ)
HNO3. User specified K-value.
Tri-ethylene Glycol / Water
Dehydration of hydrocarbon systems SRK
Dehydration (TEG)
Flory-Huggins (FLOR) Polymer solutions LATE
UNIFAC for Polymers
Polymer solutions LATE
(UPLM)(2)
Elliott-Suresh-Donohue Hydrogen bonding, also at high
SRK
(ESD)(1) pressure
Hydrogen bonding, also at high
SAFT (1) SRK
pressure
ACTX User specified activity coefficients LATE
K Tables User specified K - value SRK or LATE
Polynomial User specified K - value SRK or LATE
User Specified Subroutine User specified K – value SRK or LATE
PAGE 29 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix IV
K Model - Henry’s Law Review
A good source for Henry’s Law constants is published by the Max-Planck Institute(6).
Henry’s law constant kH can be defined as:
k H = Ca pg
where Ca is concentration of species in the aqueous phase
pg is the partial pressure of that species in the gas phase
kH is at standard conditions where k θH is at T = 298.15K
3
mol aq dmaq
The common units for kH are M atm =
atm
3
mol aq maq
The official SI units for kH are M Pa =
Pa
kH kH
To convert between above unit
M atm
= 101.325
[
(molaq maq3 ) Pa ]
px
A commonly used unit is atm where k H × k H ,Inv = 55.3 a constant for water.
M atm atm
For the carbon capture CO2 – Genosorb system we have:
px
k H ,Inv pg ρfluid
= = = 3.67
atm xa mw fluid
An alternative definition for Henry’s Law is given by:
pg
H = where pg = y g P
xa
This relates xa the equilibrium mole fraction of the species in the liquid phase to its partial
pressure pg in the gas phase. Mole fraction of that species in the gas phase is yg where P is the
total system pressure. In this last case units for H are Pa / mole fraction liquid.
The Henry’s Law constant is a function of temperature and independent of total pressure at low
pressures. It can be seen that the H2S/Water and CO2/Water systems are significantly more
soluble than the N2/Water and CO/Water systems.
Henry’s Constant Data at 25ºC
Max-Planck Institute Raschig
System
M/atm bar bar
N2/Water 0.00063 87000
CO2/Water 0.034 1600 1440
H2S/Water 0.1 553
CO/Water 0.00091 60700
In CHEMCAD Henry’s Law data is given for CO2 solubility in water under Parameteric Data.
This data is presented as coefficients using the temperature dependent correlation below:
A pg
H = Exp + B ln T + C T + D where H =
in units psia/mol fraction and T is in ºR.
T xa
Henry’s Law temperature dependence can also be determined from the following correlation:
−∆ 1 1
= θ so ln H − where Tθ =298ºK
kH kH exp T θ
R T
PAGE 30 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix V
Inert Gases and Infinitely Dilute Solutions
When inert gases, such as CO2, N2, H2 etc., are present with non-ideal chemicals, they present
some computational difficulties when using activity models. The K-value is calculated using:
ν i V pi
Ki =
P
The problem with this method, as far as inert gases are concerned, is that the system is very often
operating above the critical point of the pure inert gas. The standard vapor pressure correlation
cannot be accurately extrapolated into this region. It is necessary, for the inert gas only, to switch to
the Henry's Gas Law method for vapor pressure representation whenever the system temperature is
above the critical temperature of a given compound.
Each time the vapor pressure is calculated, CHEMCAD compares the critical temperature of each
compound to the system temperature. If the system temperature is greater than the critical
temperature of one or more of the compounds, then the program will check to see if the Henry's
constants are present for the components in question. If the Henry's constants are present, then, for
the "inert" compounds only, CHEMCAD will represent the vapor pressure using the Henry's
method. All other components will use the regular vapor pressure equation. If the Henry's
constants are not present, then the program remains with the regular default vapor pressure method.
In certain unusual cases, this approach can cause some numerical difficulties. If the system happens
to be operating right in the vicinity of the critical point of one of the components, then it is possible
that on one iteration the calculation will be above the critical temperature and on the next it will be
below the critical temperature. This will cause the program to switch back and forth between vapor
pressure methods, causing numerical discontinuities and non-convergence. This problem can be
overcome by telling the program to use the Henry's method globally for certain components. This
is done on the K-value screen.
The thermodynamic properties of infinitely dilute solutions is acknowledged as being very difficult
to predict and systems involving these conditions should always have the results from process
simulation work validated by experimental data.
PAGE 31 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix VI
In the study of post combustion carbon capture the K-Amine and H-Amine CHEMCAD model
has been successfully applied in the study of the absorption and desorption of CO2 in
ethanolamine solutions. Aqueous solutions of ethanolamines are used for the reactive
absorption of CO2 at atmospheric pressure. The reaction mechanisms are as follows:
In CHEMCAD Amine model uses the Kent Eisenberg method to model the reactions. The
following amines are included in the Amine model allowing for further investigation as
required.
Diethanolamine (DEA)
Monoethanolamine (MEA)
Methyl diethanolamine (MDEA)
The chemical reactions in the CO2-Amine system are described by the following reactions:
RR'NH2+ ↔ H+ + RR'NH
RR'NCOO + H2O ↔ RR'NH + HCO3
CO2 + H2O ↔ HCO3- + H+
HCO3- ↔ CO3- - + H+
H2O ↔ H+ + OH-
The reaction equations are solved simultaneously to obtain the free concentration of CO2. The
partial pressure of CO2 is calculated by the Henry's constants and free concentration in the
liquid phase. The heat of reaction is also accurately predicted to allow thermal studies to be
carried out.
In the study of CO2 Compression and Transport, due to CO2 being close to the super-critical
state in which the temperature is greater than the critical temperature, makes fugacity
calculation difficult. The Benedict Webb Ruben Starling equation of state has been used
because it is the only E-o-S that allows specific parameters for CO2, shown below, to be used.
PAGE 32 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix VII
Thermodynamic Guidance Note
1. If no data is available UNIFAC / UNIFAC LLE is a 'reasonable' model to try. It will predict
results that are consistent and it is not unreasonable to trust UNIFAC to be near the results. The
more non-ideal the organic the less accurate the results. If using NRTL / UNIQUAC, for other
reasons, regress the behaviour of water-organic from UNIFAC.
3. If some data is available and sufficiently reliable, regress binary interaction parameters (BIPs)
without UNIFAC.
Only use UNIFAC if it matched data and there were difficulties regressing the data into NRTL or if
wanting to use UNIFAC for some other reason. If there are NRTL/UNIQUAC parameters and some
data for validation, use the data to validate BIPs.
1. To determine pure component properties (Tb, Tc, Pc) for hydrocarbons, 15% accuracy is typical
for straight branch, C8 and lower hydrocarbons. See Appendix VIII for predictive methods.
2. Determining non-real binary behaviour due to size and shape of the two molecules.
The UNIFAC groups and their interactions are used to calculate the liquid fugacity and to determine
the size and shape of a 'part' of the molecule. Regressing BIPs for UNIFAC makes it more useful.
When UNIFAC is insufficient for the components you can still use it for the vapor phase, but it fails
on the liquid phase and on TPxy behaviour.
Interaction parameters between groups dictate the interaction between groups. The overall
behaviour is the sum of partial interactions. If the interactions between some of the groups for two
components are not available, it means that the groups are being ignored. For example acetic acid
and xylene have groups that do not have known interaction parameters, which means that part of the
shape of the two is being ignored.
There is no H2O group. This means that water is considered to be an ideal circle of ideal gas law
size when interacting with another component. H2O is not a sphere, so the liquid fugacity
calculation is wrong. The liquid fugacity for xylene-water and xylene-acetic acid is assumed to be
'regular solution,' and the liquid fugacity for xylene-acetic acid is an incomplete result.
UNIQUAC or NRTL with vapor phase association. UNIFAC is not suitable due to lack of
interaction parameters for the main groups acetic acid and xylene and there is no water subgroup.
PAGE 33 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix VII
Thermodynamic Guidance Note
Liquid Liquid Extraction
To select a K model that will support the calculation of two liquid phases, set the vapor/
liquid/liquid/solid option on the K value screen. Models NRTL, UNIQUAC, UNIFAC LLE are
suitable.
It is possible to regress Txy data for a pair of components but be sure to set the K flag V/L/L/S
option before regressing, because different regressions are used. Txy data can also be regressed for
a ternary system, such as data from a binodal.
For a discussion on alpha functions influence on the calculation of activity coefficients for the two
liquid phases reference: Smith and Van Ness, “Introduction to Chemical Engineering Thermodynamics”.
When using an activity coefficient model to determine equilibrium between two liquid phases, the
SCDS UnitOp can be used to determine separation and gamma1, gamma2 show
separation regardless of what the two phases are. The calculations for LLE on a stage are the same
that would be used for VLE on a stage. There is a special UnitOp, the extractor (EXTR) which is
nothing more than an SCDS unit modified to work for two liquid phases rather than one liquid
phase and one vapor phase. Whenever your data is expressed as an activity coefficient, you could
use the gamma regression.
The Flash UnitOp will always bring the vapor and liquid to equilibrium, which is equivalent to a
Murphree Efficiency of 1.0. Binodal plots should be obtained for verification of partitioning
behaviour. To do a single stage liquid - liquid extraction with Murphree efficiency applied Excel
UnitOp can be used to design a special UnitOp. For such low extractions set 2 stages with
efficiencies of around 0.2 to 0.3 LLE UnitOp needs a minimum of 2 stages and a single flash gives
equilibrium.
Regressing BIPs for NRTL( K flag set for V/L/L/S) for LLE when using UNIFAC LLE with water
present is acceptable provided the water is forming a second phase, it is always best to check with
data though.
General Rules
Liquid phase water with “anything else” most times use NRTL. You can regress NRTL BIPs for the
other components from UNIQUAC or UNIFAC if you don't have NRTL bips.
SRK is an equation of state which uses the accentric factor of a component and some 'general curve
fit' parameters from “lots of lab studies” to calculate the fugacity on the basis that both molecules in
the binary mixture are spheres, the only difference is how big they are. Again, water is not a sphere
and it's non-ideal behavior stems from its shape as well as its size.
Peng Robinson and SRK Equations of State are good for non-water mixtures of gases and excellent
for light gases and refrigerants. However they cannot handle two phase water but are good for two
phase hydrocarbons. Great for non-polar, not so good for polar solutions.
PAGE 34 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
Appendix VII
Thermodynamic Guidance Note
You can regress a BIP for binary behaviour which is really just a mixing bip (Kij=Ki/Kj=A+B*T)
If using an EOS with water there are two methods:
1. Use NRTL and turn on either Vapor Fugacity Correction (use SRK for the vapor phase fugacity)
2. Use NRTL with Henry's component set for near supercritical light gases.
Activity coefficients are good for polar solutions, if you have activity coefficient bips regressed.
UNIFAC is good for hydrocarbons, even polar hydrocarbons, if you have subgroups. Not good if
there is a liquid phase.
Batch Distillation
For a multi-component organic-water system, with regressed vapor pressure data, the first choice
would be NRTL. An equation of state is unsuitable unless the accentric factor is tuned; more details
are available in the Help section.
When using the pseudo binary method to correlate the behaviour of a mixture based on the
behaviour of pairs of components to each other, the situation may occur where this isn't valid (phase
partitioning, ternary azeotropes) because the ternary, quaternary system behaves significantly
different than pseudo binary predicts. When guessing BIPs from UNIFAC this can be a danger.
When uncertain of BIPs it is not wise to make column specifications based on composition. VLE
data is available from DECHEMA.
Enter the User Component screen for the physical property to be regressed and enter the upper and
lower limit temperatures with the relevant physical property data in the correct units. Note the
regression equation on this “screen is not set in stone” and may be changed.
Density is particularly difficult to achieve a regression and changing the equation to 100 the straight
line function may help as density approximates to this over a narrow range.
Successful results can be achieved with two data points only, but ensure that data at 0°C is not
entered. Key data points can be weighted e.g. 10000 to force regression through the point.
If it is not a hydrocarbon use Joback or UNIFAC depending on the compound and do not enter an
SG; note this should have no effect on pure component regressions. If user component below mp at
60ºF do not enter SG. Joback is easier to get halogens into, more flexible groups, but UNIFAC does
a better job characterizing Poly Cyclic compounds.
When using UNIFAC if error message saying "UNIFAC groups unspecified for component" there
are no groups and the activity coefficient for that component is set = 1 ie basis will be taken as ideal
behaviour
The most important thing is to try it several ways, and understand that these estimation methods DO
NOT replace the need for actual lab data on your compound. Once laboratory data is available the
issue is resolved.
PAGE 35 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
APPENDIX VIII
Predictive Procedures
CHEMCAD uses individual component DIPPR coefficients for the common temperature dependent
variables such as vapour pressure, liquid density and viscosity. If DIPPR coefficients cannot be
sourced then alternative estimating procedures are resorted to.
Two group contribution methods, namely Lyderson/Joback and UNIFAC, are available for
estimating properties from functional groups contained in the molecule. If the functional group is
not available, as is the case with most organo-phosphorous compounds, these methods cannot be
used. To handle functional groups containing phosphorus copy a similar compound and then edit
the HoV, VP, et al curves with real data.
However, the Benson method includes some data for many compounds and can be used to predict
standard state Cp, ∆Hf, S. This information could be extended to include components not included
using additivity rules.
S.W.Benson “Additivity Rules for the Estimation of Thermochemical Properties” J.Chem.Phys., pp309-310, 29, 546 (1968)
Model Parameter Intrinsic value required for CHEMCAD prediction (Notes 1&2)
Liquid Density Tc Pc Vc, liquid volume constant, Rackett constant
Liquid Viscosity Tc Pc ω
Vapour Viscosity Tc Pc, Dipole Moment, Molecular diameter
HoV Tb
Enthalpy Datum IG heat of formation
Heat of Reaction IG heat of formation, HoV(no DIPPR)
EoS K Values Tc Pc Vc ω
Latent Heat HoV(no DIPPR)
Heat Balance Cp
Vapour Pressure Tb ω
Notes
1. CHEMCAD will always use DIPPR coefficients if available with the exception of the IG heat
capacity polynomial equation which is the default.
2. Method due to Klincewicz derives critical temperature Tc with an expected error of 2%.
PAGE 36 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
APPENDIX VIII
For modelling reactions in the liquid phase the following component properties are required:-
• Chemical formula.
• Molecular weight M.
• Liquid heat capacity Cp.
Two data points in operating range preferred. Less important if reaction is isothermal.
If the problem component is very dilute the solution Cp can be used since enthalpy is a
partial molar property and if xi is small you can assume the solution Cp will not be
significantly influenced.
• Specific gravity at 20°C.
If the problem component is very dilute the solution liquid density ρf can be used.
• Ideal Gas (IG) Heat of Formation or Heat of Reaction.
It is doubtful that Ideal will apply, and UNIFAC VLE will also not suitable for this case.
PAGE 37 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
Process Modelling
Selection of Thermodynamic Methods
APPENDIX VIII
• S. W. Benson, F.R. Cruickskank, D.M. Golden. G.R. Haugon, H.E. O’Neal, A.S. Rodgers,
R. Shaw, and R. Walsh, Chem. Rev. 69, 279-324 (1969).
• S. W. Benson, ‘Thermochemical Kinetics, 2nd Edition, ‘John Wiley and Sons, New York
(1976).
• S. W. Benson and J. H. Buss, J. Chem. Phys. 19, 279 (1968).
• F. N. Fritsch and R. E. Carlson, SIAM J. Numerical Analysis 17, 258-46 (1980).
• F. N. Fritsch and J. Butland, UCRL-85104, Lawrence Livermore Laboratory, October, 1980.
• B. K. Harrison and W. H. Seaton, ‘A solution to the missing group problem for estimation
of ideal gas heat capacities,’ Ind. Eng. Chem. Res. 27, 1536-40 (1988).
• J. E. Hurst, Jr., and B. K. Harrison, ‘Estimation of liquid and solid heat capacities using a
modified Kopp’s rule,’ Chem. Eng. Commun, 112, 21-30 (1992).
• C. D. Ratkey and B. K. Harrison, ‘Prediction of enthalpies of formation for ionic
compound,’ Ind. Eng. Chem. Res. 31 (10), 2362-9 (1992).
• W. H. Seaton, ‘Group Contribution Method for Predicting the Potential of a chemical
composition to cause an explosion, J. Chem. Educ. 66, A137-40 (1989).
• C. A. Davies, D .J. Frurip, E. Freedman, G.R. Hertel, W.H. Seaton, and D. N. Treweek,
‘CHETAH 4.4: the ASTM chemical thermodynamic and energy release program,’ 2nd
edition, ASTM Publication DS 51A (1990).
• J. R. Downey, D. J. Frurip, M. S. LaBarge, A. N. Syverud, N. K. Grant, M. D. Marks, B. K.
Harrison, W.H. Seaton, D. N. Treweek, and T. B. Selover, ‘CHETAH 7.0 Users Manuals:
the ASTM Computer program for chemical thermodynamic and energy release evaluation,’
NIST Special Database 16, ASTM, ISBN 0-8031-1800-7, Philadelphia, PA (1994).
• Gustin, J.L., "Thermal Stability Screening and Reaction Calorimetry. Application to
Runaway Reaction Hazard Assessment at Process Safety Management, J. Loss Prev. Process
Inc., Vol. 6, No. 5, (1993).
• Ching-Li Huang, Dr. Keith Harrison, Jeffry Madura, and Jan Dolfing, Gibbs Free Energies
of Formation of PCDDS: Evaluation of Estimation Methods and Application for
Predicting Dehalogenation Pathways, Environmental Toxicology and Chemistry, Vo. 15,
No. 6, pp. 824-836, 1996.
PAGE 38 OF 38
MNL 031B Issued November 2008, Prepared by J.E.Edwards of P & I Design Ltd, Teesside, UK www.pidesign.co.uk
IDEAL SOLUTION Txy DIAGRAM Figure 1
Dew pt
Bubble pt
ENTHALPY ISOBAR Figure 2
Ts q=1
Liquid Vapour- liquid Superheated
vapour
Reference h L Hsup
Tr=298K
Sensible Latent(dryness q) Superheat
Heat added Q
THERMODYNAMIC PHASES Figure 3
Critical
Isotherm
Pressure
P Critical
Point van der Waals RT- a
P=
Pc equation V-b V2
Ps
LLE Zone VLE Zone E-o-S Zone
Isotherms
Single Two phases Single phase
phase vapour liquid gas
liquid
Liquid-gas
Coexistence curve
Volume V
van der Waals EQUATION of STATE Figure 4
PRESSURE(bar)
P=(RT/(V-b))-(a/V^2) 15.00
a=(27/64)(R^2)(Tc^2)/Pc 5.00
b=(RTc)/(8Pc) 0.00
0 50 100 150 200 250
R=83.144 (bar.cm^3)/(mol.K)
V OLUM E (cm 3/gm ol)
Reference:
Reid,Prausnitz,Poling
Properties Gases Liquids VAN DER W AAL >Tc(100K)
Table 3-5 p42
300.00
250.00
PRESSURE(bar)
200.00
150.00
100.00
50.00
0.00
0 50 100 150 200 250
V OLUM E(cm 3/gm ol)
4.00
3.50
PRESSURE(bar)
3.00
2.50
2.00
1.50
1.00
0.50
0.00
0 50 100 150 200 250
V OLUM E(cm 3/gm ol)
RELATIVE VOLATILITY IN VLE DIAGRAM Figure 5
α = 2.5 α = 4.0
α = 3.0 α = 10
AZEOTROPE γ VALUE IN VLE DIAGRAM Figure 6
EtAc
bp 77C
Azeotrope Hexane
bp=65C bp 69C
Azeotrope
X1=0.62
γ1=1.135
γ2=1.428
γ1=2.62
γ2=2.41
VLE DIAGRAM AND CONVERGENCE EFFECTS Figure 7
CHEMCAD K AND H VALUES WIZARD Figure 8
COMP
SINGLE MULTI
?
HEAVY HC
CHEMICAL OTHER CHEM< 10 BAR OTHER
? ?
> -70ºC
Data ij > 50%
CHEM> 10 BAR
NRTL, UNIQUAC T
K=VAP K=VAP WILSON (Not LL)
H=LATE H=SRK Data ij < 50%
UNIFAC LLE < -70ºC
NG - CO2 K=SRK
UNIFAC (Not LL) H=SRK
SPECIAL METHODS H=LATE (all)
K=BWRS
H=BWRS For P > 50 PSI
AMINE
Activate Poynting
K=AMINE H=AMINE Data ij > 50%
SOUR SRK, PR
K=SOUR H=SRK Data ij < 50%
POLYMER < 7 BAR > 7 BAR SRK, PSRK
K=UPLM H=LATE P H=LATE (all)
HCL/NH3
K=PPAQ H=SRK K=ESSO K=GS K=PR
HTSL (90 to 200ºC) (P < 200BAR) H=PR
H=LK H=LK
K VALUE MODEL DECISION TREE Figure 9
PHASE
GAS LIQUID
?
NAT GAS
VLE
VAP ONLY or CO2 LIQUID LLE
? ?
AZEOTROPE
HYDROCARBON
GAS EQUATION BENEDICT IDEAL BIP MODEL
SOAVE WEBB RUBIN VAPOR LLE BIPS
REDLICH STARLING
KWONG(SRK) (BWRS) H=LATENT HEAT H=LATENT HEAT
NRTL (5 PAR)
UNIQUAC (2 PAR)
PENG
UNIFAC(INCREM)
ROBINSON
IDEAL
H=PENG ROBINSON NO YES H=LATENT HEAT
?
NRTL (5 PAR) IDEAL VAP PRESS
UNIQUAC (2 PAR) GAS EQUATION
UNIFAC(INCREM) BIP MODEL
www.chemstations.com
Agenda
2
Background of Case Study
3
Original Steady State Simulation
4
Goals of Case Study
5
Determining Scope of Model
6
Simulation Guidelines
7
Start with a Simple Model
8
Simplified Flowsheet
9
Change to Dynamic Simulation Mode
10
Startup Conditions
11
Tower & Feed Configuration
12
Actual Data Determined Ramp Settings
13
Scope of Model
14
Accumulator Dimensions & Reflux
Set reflux
to zero
initially
15
Accumulator Level Target Specification
16
Get Dynamic Model to Converge
17
Run Time Parameters
18
Accumulator Level Plot
19
Accumulator Level Target Reached
30 min
20
Scope of Model
21
Place Reflux System In Service
Switch to
maintain
level &
adjust
reflux rate
22
Scope of Model
23
Start Stripping Steam to Tower
24
Scope of Model
25
Product Stream Reaching Specification
30 min after
reflux begins
26
Scope of Model
27
Validating Results
28
Further Validation of Results
29
Add Complexity As Required
• Fired heater
• Reflux/distillate control valves
• Pumparounds/side strippers
• Relief valve studies
• Additional upstream / downstream units
30
Switch Back to Steady State Model
31
Review Simulation Guidelines*
• Start with a simple model
– Fix what you can, i.e. pressures, etc.
– Ignore what you can, i.e. utilities, etc.
• Get model to converge
• Validate results
• Add complexity as required to reach desired
engineering solution
– more detail may not be better!
– i.e. don’t add utilities controls systems to flowsheet
just because they’re on the P&ID
33
PROCESS SIMULATION USING DWSIM 27 August 2022
By Viraj Desai, Process Engineer
BY
VIRAJ DESAI, PROCESS ENGINEER
EMAIL: VIRAJ DESAI
LEVEL: BASIC
VERSION: 0.00
AUG 2022
1
PROCESS SIMULATION USING DWSIM 27 August 2022
By Viraj Desai, Process Engineer
PREFACE
The manual “Process Simulation Using DWSIM” presents a set of basic exercises using a free and
open-source chemical process simulator “DWSIM” and can be utilized to establish process
simulation laboratory as part of undergraduate chemical engineering degree or in allied degree
curriculum. Simulation covers topics across the broad spectrum of chemical engineering courses
covering mixing, reaction, phase equilibrium, heat, and mass transfer operations. The problem
statements are rightly placed at the beginner’s level with each exercise completes in terms of
sufficient instructions that enable the learner to perform the exercise with ease on their own.
Supplementary self-learning exercises are also provided for simulation experiments to further aid a
curious learner.
Thanks
Viraj Desai
P.E. O&G
Disclaimer
All the exercises are strictly restricted to learning only and not meant to be used in real world
application.
2
PROCESS SIMULATION USING DWSIM 27 August 2022
By Viraj Desai, Process Engineer
PREAMBLE
The objective of the course is to create awareness of the open-source process simulator “DWSIM”
among prospective graduates and practicing process engineers. The course will cover basic aspects
of create flow sheet in DWSIM and simulation of simple units such as Mixer, Splitters, CSTR,
Distillation column, Pumps, Turbines, Compressors, etc.
Target Audience
3
PROCESS SIMULATION USING DWSIM 27 August 2022
By Viraj Desai, Process Engineer
Table of Contents
4
PROCESS SIMULATION USING DWSIM 27 August 2022
By Viraj Desai, Process Engineer
List of Figures
5
Mixing of Ideal Liquid Streams 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process sheet to mix two liquid streams and estimate the flow rate and
composition of outlet stream.
Data
• Mixer
• Material Stream
• Indicators (Digital or Analog)
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - CLASSIC UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add
components required to solve the problem statement. In the present case, add Water and
Methanol. Ensure all components are added from the same property database. For instance,
in this case, both components are added from “ChemSep” database.
3. Specify the thermodynamic package as Raoult’s law.
4. Customize the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. First, let provide input and
output streams for the unit operation to be performed. Drag and drop two Material streams
available at the right, in the object palette. Rename them stream as “Inlet-Stream-1”and
“Inlet-Stream-2”. These serve as input streams.
6. On clicking the “Inlet-Stream-1” and “Inlet-Stream-2” stream, general information about the
stream will be displayed on the left side of screen. Specify the feed compositions,
temperature, and pressure for the inlet streams. Once credentials are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Outlet Stream”. This serves as output stream.
8. Below the Unit Operation tab on left, locate the Stream Mixer block. Drag and drop into the
flow sheet. Rename it as “Mixer”.
9. No separate specification is required for the “Mixer” block.
10. Add digital and analog indicators for the material streams and mixer as shown in the figure
below and give targeting properties.
6
Mixing of Ideal Liquid Streams 27 August 2022
By Viraj Desai, Process Engineer
Figure 1 Mixer
11. Now, all necessary credentials required for simulation are added. It should be connected in a
proper sequence. Click on “Mixer” block, the general information about the block is
displayed on the right. Under “connections” tab, for all streams click the dropdown button
and select the necessary connections. If all the connections are given correctly, all the blocks
will turn blue.
12. Run the simulation by pressing “Solve flow sheet” button on the top corner of the screen.
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
7
Mixing of Ideal Liquid Streams 27 August 2022
By Viraj Desai, Process Engineer
8
Determination of Thermo-physical Properties of Pure Component 27 August 2022
By Viraj Desai, Process Engineer
Objective
Data
• Fluid: Water
• Thermodynamic model: Ideal
DWSIM Block
• Material Stream
• Digital indicators
Procedure
1. Start a new DWSIM simulation (DWSIM VER 8.0 - CLASSIC UI). Click on “New steady state
simulation” as a template for new simulation
2. The simulation configuration window will be opened. The specification page will appear.
Select the component required for the simulation. In this case Water is added.
3. Select and add the property package (Raoult’s law) and click “Next”. Add the default flash
algorithm for the simulation. Click “Next”.
4. Choose the desired system of units for the simulation and click “Next”.
5. The flow sheeting section will be opened.
9
Determination of Thermo-physical Properties of Pure Component 27 August 2022
By Viraj Desai, Process Engineer
6. Add a material stream and give the conditions provided in the data and add digital indicators
for targeting the properties
7. In the top menu, under the “Tools” tab, click on “Pure component property viewer” to
generate thermo-physical property data.
10
Determination of Thermo-physical Properties of Pure Component 27 August 2022
By Viraj Desai, Process Engineer
8. On clicking the tab, pure component property window will appear. Select the component for
which the thermo-physical data must be generated. In this case it is water.
9. Once you selected the component, the appearance of window will be changed as shown in
figure.
11
Determination of Thermo-physical Properties of Pure Component 27 August 2022
By Viraj Desai, Process Engineer
10. Below the component tab, identify a tab named “Liquid-phase”. On clicking this tab, a graph
for temperature versus specific heat capacity of water will be generated.
11. Similarly you can also generate for vapourization enthalphym vapour pressure, surface
tension, viscosity,density and so on.
12. To view the results in tabulated form, click on “Data-table” option where, all the thermo-
physical properties are tabulated.
12
Generation of VLE Data of Binary Component System 27 August 2022
By Viraj Desai, Process Engineer
Objective
Data
• Fluid components: Benzene - Toluene
• Pressure = 1 atm
• Thermodynamic model: Ideal
DWSIM Block
• Material Stream
Procedure
1. Start a new DWSIM simulation (DWSIM VER 8.0 - CLASSIC UI). Click on “New steady state
simulation” as a template for new simulation
2. The simulation configuration window will be opened. The specification page will appear.
Select the components required for the simulation, namely “Benzene” and “Toluene”.
Ensure, components are added from same property database. In this illustration, both
components are added from “ChemSep” database.
3. Select and add the property package (Raoult’s law) and click “Next”. Add the default flash
algorithm for the simulation. Click “Next”.
4. Choose the desired system of units for the simulation and click “Next”.
5. The flowsheeting section will be opened.
6. Add a material stream and specify the data.
13
Generation of VLE Data of Binary Component System 27 August 2022
By Viraj Desai, Process Engineer
7. To generate binary VLE, at least one material stream is required in the flowsheeting section.
Hence, click on material stream object at the object palette and drag it to the flowsheet
section.
8. Click the “material stream” to open its specification window. Next to the object name, you
will find an icon, click it to attach utility and under utility add an “Binary Envelope” as shown
in the figure below.
9. A new window opens. Enlarge it. Use the different pull down menus available in the window
to generate the Txy and VLE plot for Benzene and Toluene at given pressure. Provide
settings as shown below and click at “Calculate” to see the Txy plot.
14
Generation of VLE Data of Binary Component System 27 August 2022
By Viraj Desai, Process Engineer
10. Similarly click on Pxy and then on “Calculate” to generate Pxy plot.
15
Generation of VLE Data of Binary Component System 27 August 2022
By Viraj Desai, Process Engineer
16
Simulation of a Flash Column 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to estimate the liquid and vapour composition of multi-
component mixture undergoing partial vaporization.
Data
• Components: n-pentane, n-hexane, and n-heptane
• Feed composition: 25 mol % n-pentane, 45 mol% n-hexane, and 30 mol% n-heptane
• Basis: 100 kmol/h
• Operating conditions
• Temperature = 69 °C
• Pressure = 1.013 bar
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation.
2. The simulation configuration window will be opened. It shows a specification page. Add the
three components - n-pentane, n-hexane, and n-heptane. Ensure that all the components
are added from same property package. Example: All the 3 components are selected from
Chemsep database. Click “Next” button.
3. Specify the thermodynamic package as Raoult’s law.
4. Customize the system of units for the present simulation and click “Next”.
5. The flowsheeting section of simulation window will be opened. It is necessary to provide
input and output streams for the unit operation to be performed. Drag and drop the
Material stream available at the right, in the object palette. Rename the stream as “Feed-
In”. This serves as the input stream.
6. On clicking the “Feed-In” stream, general information about the stream will be displayed on
the left side of screen. Specify the feed compositions, flow rate, temperature, and pressure
17
Simulation of a Flash Column 27 August 2022
By Viraj Desai, Process Engineer
for the stream, once composition and flow rate are specified for the inlet stream, the color
7. Add two more Material streams i.e., Drag and drop it into the flowsheet. Rename those
streams as “Vap-Out”, “Liq-Out” & “Heavy-Out”. These serves as output streams.
8. Below the unit operation tab on left, locate the Gas-Liquid Separator block. Drag and drop
into the flow sheet. Rename it as “Flash Column”.
9. Now, all necessary credentials required for simulation are added. It should be connected in a
proper sequence. Click on “Flash Column” block, the general information about the block is
displayed on the right. Under “connections” tab, for all streams click the dropdown button
and select the necessary connections. If all the connections are given correctly, all the blocks
will turn blue.
10. Add Flow transmitters as indicators in all the streams and target mass flow as property.
11. For column add a pressure transmitter, and target pressure.
12. Run the simulation by pressing “Solve flow sheet” button on the top corner of the screen. It
will be in the shape of Triangle.
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which must be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
18
Simulation of a Flash Column 27 August 2022
By Viraj Desai, Process Engineer
19
Simulation of a CSTR for Liquid Phase Reaction 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process sheet to determine the exit composition from a Continous stirred tank
reactor (CSTR)
Data
• Reaction: Ethylene glycol production in CSTR: Ethylene oxide reacts with water to form
Ethylene Glycol
𝐶2 𝐻4 𝑂(𝑙) + 𝐻2 𝑂(𝑙) → 𝐶2 𝐻6 𝑂2(𝑙)
• Inlet stream: 26 m3/h of aqueous solution of Ethylene oxide with a mol fraction of 15% and
rest water. Reaction carried out at 55 °C under atmospheric condition in CSTR of 2 m3
• Reaction rate: −𝑟 = 𝑘𝐶𝐸0
• Where CEO: Molarity of Ethylene oxide; k: rate constant = 0.005 1/s
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - CLASSIC UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. Add 3 components for the simulation -
Ethylene oxide, Ethylene Glycol and Water
3. Ensure that all the components are added from same property package. Example: All the 3
components are selected from Chemsep database. Click “Next” button.
4. Select and add the property package and click “Next”. Add the default flash algorithm for the
simulation. Click “Next”.
5. The flowsheeting section of simulation window will be opened. Drag and drop the Material
stream from the object palette and rename the stream as “Feed”. This serves as input.
6. On clicking the “Feed” block, general information about the block will be displayed on the
left of the screen.
7. Specify the feed compositions, flow rate, temperature, and pressure for the inlet streams
once composition and flow rate are specified for the inlet streams, the color of stream turns
blue.
8. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename it as
“Product”. This serves as output stream.
9. Add an energy stream which is available in the object palette below the Material stream.
10. Below the Unit Operation tab, locate the “Continous Stirred Tank Reactor” CSTR block. Drag
and drop into the flow sheet. Rename it as “CSTR”.
11. Under “Tools” tab in select “Reaction Manager” tab. choose the type of reaction i.e.,
“Equilibrium reaction” for this problem. A dialogue box will appear. Give an appropriate
20
Simulation of a CSTR for Liquid Phase Reaction 27 August 2022
By Viraj Desai, Process Engineer
12. Select the checkboxes adjacent to the component names, which has to be included in the
reaction. Give the stoichiometry of the reaction and choose appropriate base component.
13. In this case the base component is “Ethylene Oxide”. Once base component, stoichiometry is
specified, a text “OK” appears in the stoichiometry tab. Specify the rate constant of the
reaction.
14. By default, the basis is activity and liquid phase. In this case it has to be changed to Molar
concentration and specify the phase as liquid.
15. Specify the rate constant of the reaction and click “OK”.
16. Click on “CSTR-REC” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. If all the connections are given correctly, the blocks will turn blue.
21
Simulation of a CSTR for Liquid Phase Reaction 27 August 2022
By Viraj Desai, Process Engineer
17. Add 2 analyzers from the indicators panel and specify molar fraction (liquid 1) / ethylene
glycol as the targeting property for both feed and product stream.
Figure 13 CSTR
18. Run the simulation by pressing “Solve flow sheet” button on the top corner of the screen.
19. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Feed Product
Temperature (K) 328.15 328.15
Pressure (Pa) 101325 101325
Mass Flow (kg/s) 6.91362 6.91362
Molar Flow (mol/s) 315.39 313.125
Volumetric Flow (m3/s) 0.00722222 0.00720902
Density (Mixture) (kg/m3) 957.271 959.023
Molecular Weight (Mixture) (kg/kmol) 21.9209 22.0794
Specific Enthalpy (Mixture) (kJ/kg) -1795.78 -1797.8
Specific Entropy (Mixture) (kJ/[kg.K]) -4.93172 -4.90951
Molar Enthalpy (Mixture) (kJ/kmol) -39365 -39694.4
Molar Entropy (Mixture) (kJ/[kmol.K]) -108.108 -108.399
Thermal Conductivity (Mixture) (W/[m.K]) 0.423148 0.424053
Molar Fraction (Mixture) / Ethylene glycol 0 0.00723287
Mass Fraction (Mixture) / Ethylene glycol 0 0.0203324
22
Simulation of a Distillation Column 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to estimate distillate and bottom composition of a distillation
column
Problem statement
100 kmol/h of an equimolar mixture of benzene and toluene at 70°C and 1 atm pressure is to be
separated by staged distillation column. A reflux ratio of 3 is used. Composition of benzene in the
distillate should be 99% (by mol) toluene in the bottom should be 99% (mol). A total condenser and
reboiler, both at 1 atm pressure are used. Determine the actual no. of stages, minimum reflux ratio
and the minimum no. of stages for the operation.
• Shortcut Column
• Material Streams
• Energy Streams
• Indicators
Thermodynamic Package
• UNIFAC.
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - CLASSIC UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. Add the two components required for
simulation - Benzene and Toluene. Ensure that all the components are added from same
property package. Example: All the 2 components are selected from Chemsep database.
Click “Next” button.
3. Select and add the property package and click “Next”. Add the default flash algorithm for the
simulation. Click “Next”.
4. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream from the object palette. Rename it as “Feed”. This serves as input stream.
5. On clicking the “Feed” stream, general information about the block will be displayed on the
left of the screen. Specify the feed compositions, flow rate, temperature, and pressure for
the inlet streams. Once composition and flow rate are specified for the inlet streams, the
color of stream turns blue. Specification for the inlet stream
6. Add two more Material streams i.e., Drag and drop them into the flow sheet. Rename them
as “Distillate” and “Bottoms”. These serves as output streams.
7. Add two energy streams, one is for condenser duty (C-Duty) and the other is for re-boiler
duty (R-Duty).
23
Simulation of a Distillation Column 27 August 2022
By Viraj Desai, Process Engineer
8. Below the Unit Operation tab, locate the “Shortcut Column” block. Drag and drop into the
flow sheet. Rename it as “DC”.
9. Click on “DC” block, the general information about the block is displayed on the left of the
screen. Provide calculation parameters as shown in the screenshot given below
10. Under Column configuration select “connections” tab. Click the dropdown button and give
appropriate connections. If all the connections are given correctly, the blocks will turn blue.
11. Add indicators on column, feed, distillate and bottom streams and target respective
properties.
12. Run the simulation by pressing “Solve flow sheet” button on the top corner of the screen.
Figure 15 Distillation
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
24
Simulation of a Distillation Column 27 August 2022
By Viraj Desai, Process Engineer
Property table
25
Determination of Heat Duty of Heater 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to determine the heat duty required to heat a fluid to a desired
temperature
Data
• Fluid: Water
• Inlet mass flow rate: 50 kg/h
• Inlet temperature: 25 °C
• Outlet temperature: 90 °C
• Pressure: 1 bar
• Heater
• Material stream
• Energy Stream
• Indicator
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This serves
as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be displayed
on the right side of screen. Specify the feed compositions, flow rate, temperature, and pressure
for the inlet streams once composition and flow rate are specified for the inlet streams, the
color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream as
“Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
26
Determination of Heat Duty of Heater 27 August 2022
By Viraj Desai, Process Engineer
9. Below the Unit Operation tab on left, locate the Heater block. Drag and drop into the flow sheet.
Rename it as “HEATER”.
10. Click on “HEATER” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. Under calculation type choose “Outlet Temperature”. If all the connections are
given correctly, all the blocks will turn blue.
11. Add temperature indicators on input and output stream and target the desired properties.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box will
appear which is double clicked to modify it further. Select the streams which have to be shown
in output and click “OK”. The property table will be opened showing all the results as shown in
the figure below.
Input Output
Temperature (K) 298.15 363.15
Pressure (Pa) 101325 101325
Mass Flow (kg/s) 0.0138889 0.0138889
Molar Flow (mol/s) 0.770951 0.770951
Volumetric Flow (m3/s) 1.39401E-05 1.43909E-05
Density (Mixture) (kg/m3) 996.327 965.118
27
Determination of Heat Duty of Heater 27 August 2022
By Viraj Desai, Process Engineer
28
Determination of Power for a Pump 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to determine the power required to pressurize a fluid for a
pump.
Data
• Fluid: Water
• Inlet mass flow rate: 50 kg/h
• Inlet Pressure: 2 bar
• Outlet Pressure: 5 bar
• Temperature: 50 °C
• Pump
• Material stream
• Energy Stream
• Indicators
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This
serves as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be
displayed on the right side of screen. Specify the feed compositions, flow rate, temperature,
and pressure for the inlet streams once composition and flow rate are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
9. Below the Unit Operation tab on left, locate thePump block. Drag and drop into the flow
sheet. Rename it as “PUMP”.
29
Determination of Power for a Pump 27 August 2022
By Viraj Desai, Process Engineer
10. Click on “PUMP” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. Under calculation type choose “Outlet Pressure”. If all the connections are
given correctly, all the blocks will turn blue.
11. Add pressure indicators on input and output stream and target the desired properties.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
Figure 19 Pump
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Output Input
Temperature (K) 323.174 323.15
Pressure (Pa) 500000 200000
Mass Flow (kg/s) 0.0138889 0.0138889
Molar Flow (mol/s) 0.770951 0.770951
Volumetric Flow (m3/s) 1.40651E-05 1.40657E-05
Density (Mixture) (kg/m3) 987.473 987.432
Molecular Weight (Mixture) (kg/kmol) 18.0153 18.0153
Specific Enthalpy (Mixture) (kJ/kg) -2336.27 -2336.67
Specific Entropy (Mixture) (kJ/[kg.K]) -7.9599 -7.53883
Molar Enthalpy (Mixture) (kJ/kmol) -42088.5 -42095.8
Molar Entropy (Mixture) (kJ/[kmol.K]) -143.4 -135.814
Thermal Conductivity (Mixture) (W/[m.K]) 0.642833 0.642807
30
Determination of Power for a Compressor 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to determine the power required to pressurize steam for a
compressor.
Data
• Compressor
• Material stream
• Energy Stream
• Indicators
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This
serves as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be
displayed on the right side of screen. Specify the feed compositions, flow rate, temperature,
and pressure for the inlet streams once composition and flow rate are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
9. Below the Unit Operation tab on left, locate theCompressor block. Drag and drop into the
flow sheet. Rename it as “COMPRESSOR”.
31
Determination of Power for a Compressor 27 August 2022
By Viraj Desai, Process Engineer
10. Click on “COMPRESSOR” block, the general information about the block is displayed on the
right. Under “connections” tab, for all streams click the dropdown button and select the
necessary connections. Under calculation type choose “Outlet Pressure”. If all the
connections are given correctly, all the blocks will turn blue.
11. Add pressure indicators on input and output stream and target the desired properties.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
Figure 21 Compressor
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Input Output
Temperature (K) 398.15 528.238
Pressure (Pa) 200000 500000
Mass Flow (kg/s) 0.0138889 0.0138889
Molar Flow (mol/s) 0.770951 0.770951
Volumetric Flow (m3/s) 0.0127601 0.00677168
Density (Mixture) (kg/m3) 1.08846 2.05103
Molecular Weight (Mixture) (kg/kmol) 18.0153 18.0153
Specific Enthalpy (Mixture) (kJ/kg) 188.254 439.466
Specific Entropy (Mixture) (kJ/[kg.K]) 0.230405 0.353053
Molar Enthalpy (Mixture) (kJ/kmol) 3391.45 7917.1
Molar Entropy (Mixture) (kJ/[kmol.K]) 4.1508 6.36036
Thermal Conductivity (Mixture) (W/[m.K]) 0.0265363 0.0391619
32
Power Generated by a Turbine 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to determine the power generated by a turbine.
Data
• Turbine
• Material stream
• Energy Stream
• Indicators
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This
serves as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be
displayed on the right side of screen. Specify the feed compositions, flow rate, temperature,
and pressure for the inlet streams once composition and flow rate are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
9. Below the Unit Operation tab on left, locate theTurbine block. Drag and drop into the flow
sheet. Rename it as “TURBINE”.
33
Power Generated by a Turbine 27 August 2022
By Viraj Desai, Process Engineer
10. Click on “TURBINE” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. Under calculation type choose “Outlet Pressure”. If all the connections are
given correctly, all the blocks will turn blue.
11. Add pressure indicators on input and output stream and target the desired properties.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
Figure 23 Turbine
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Output Input
Temperature (K) 386.222 398.15
Pressure (Pa) 200000 500000
Mass Flow (kg/s) 0.0138889 0.0138889
Molar Flow (mol/s) 0.770951 0.770951
Volumetric Flow (m3/s) 1.46424E-05 1.47898E-05
Density (Mixture) (kg/m3) 948.538 939.084
Molecular Weight (Mixture) (kg/kmol) 18.0153 18.0153
Specific Enthalpy (Mixture) (kJ/kg) -2061.48 -2005.9
Specific Entropy (Mixture) (kJ/[kg.K]) -5.59367 -5.70333
Molar Enthalpy (Mixture) (kJ/kmol) -37138.1 -36136.8
Molar Entropy (Mixture) (kJ/[kmol.K]) -100.771 -102.747
Thermal Conductivity (Mixture) (W/[m.K]) 0.685443 0.687684
34
Pressure Drop across a valve 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to determine the pressure drop across a valve.
Data
• Fluid: Water
• Inlet mass flow rate: 50 kg/h
• Inlet Pressure: 5 bar
• Outlet Pressure: 2 bar
• Temperature: 50 °C
• Valve
• Material stream
• Indicators
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This
serves as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be
displayed on the right side of screen. Specify the feed compositions, flow rate, temperature,
and pressure for the inlet streams once composition and flow rate are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
9. Below the Unit Operation tab on left, locate theValve block. Drag and drop into the flow
sheet. Rename it as “VALVE”.
35
Pressure Drop across a valve 27 August 2022
By Viraj Desai, Process Engineer
10. Click on “VALVE” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. Under calculation type choose “Outlet Pressure”. If all the connections are
given correctly, all the blocks will turn blue.
11. Add pressure indicators on input and output stream and target the desired properties.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
Figure 25 Valve
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Output Input
Temperature (K) 298.223 298.15
Pressure (Pa) 200000 500000
Mass Flow (kg/s) 0.0138889 0.0138889
Molar Flow (mol/s) 0.770951 0.770951
Volumetric Flow (m3/s) 1.39402E-05 1.39392E-05
Density (Mixture) (kg/m3) 996.323 996.389
Molecular Weight (Mixture) (kg/kmol) 18.0153 18.0153
Specific Enthalpy (Mixture) (kJ/kg) -2440.55 -2440.55
Specific Entropy (Mixture) (kJ/[kg.K]) -8.49746 -8.92232
Molar Enthalpy (Mixture) (kJ/kmol) -43967.2 -43967.2
Molar Entropy (Mixture) (kJ/[kmol.K]) -153.084 -160.738
Thermal Conductivity (Mixture) (W/[m.K]) 0.610357 0.610248
36
Residence Time Calculation for a Tank 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to determine residence time for a given volume of tank.
Data
• Fluid: Water
• Inlet mass flow rate: 500 kg/h
• Inlet Pressure: 1 bar
• Outlet Pressure: 1 bar
• Temperature: 50 °C
•
Tank Volume: 5 m3
• Tank
• Material stream
• Indicators
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This
serves as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be
displayed on the right side of screen. Specify the feed compositions, flow rate, temperature,
and pressure for the inlet streams once composition and flow rate are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
37
Residence Time Calculation for a Tank 27 August 2022
By Viraj Desai, Process Engineer
9. Below the Unit Operation tab on left, locate the Tank block. Drag and drop into the flow
sheet. Rename it as “TANK”.
10. Click on “TANK” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. Under calculation type choose “Tank Volume”. If all the connections are given
correctly, all the blocks will turn blue.
11. Add flow indicators on input and output stream and target the desired properties and add
time indicator on tank.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
Figure 27 Tank
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Input Output
Temperature (K) 298.15 298.15
38
Residence Time Calculation for a Tank 27 August 2022
By Viraj Desai, Process Engineer
39
Flow Split with Splitter 27 August 2022
By Viraj Desai, Process Engineer
Objective
Develop a simple process flow sheet to split a given mass flow into equal proportions.
Data
• Fluid: Water
• Inlet mass flow rate: 90 kg/h
• Inlet Pressure: 1 bar
•
Temperature: 50 °C
• Splitter
• Material stream
• Indicators
Procedure
1. Start a new DWSIM Simulation (DWSIM VER 8.0 - Classic UI). Click on “New steady state
Simulation” as a template for new simulation
2. The simulation configuration window will be opened. It shows a specification page. Add the
component “Water”
3. Specify the thermodynamic package as Raoult’s law.
4. Select the system of units for the simulation and click “Next”.
5. The flow sheeting section of simulation window will be opened. Drag and drop the Material
stream available at the right, in the object palette. Rename the stream as “Flow-In”. This
serves as input stream.
6. Double click the “Flow-In” stream. The general information about the stream will be
displayed on the right side of screen. Specify the feed compositions, flow rate, temperature,
and pressure for the inlet streams once composition and flow rate are specified for the inlet
streams, the color of stream turns blue.
7. Add one more Material stream i.e., Drag and drop it into the flow sheet. Rename the stream
as “Flow-Out”. This serves as the output stream.
8. Add an energy stream from the object palette to the flow sheeting section.
9. Below the Unit Operation tab on left, locate the Splitter block. Drag and drop into the flow
sheet. Rename it as “SPLITTER”.
40
Flow Split with Splitter 27 August 2022
By Viraj Desai, Process Engineer
10. Click on “SPLITTER” block, the general information about the block is displayed on the right.
Under “connections” tab, for all streams click the dropdown button and select the necessary
connections. Under calculation type choose “Tank Volume”. If all the connections are given
correctly, all the blocks will turn blue.
11. Add flow indicators on input and output stream and target the desired properties.
12. Run the simulation by clicking on “Solve flow sheet” icon / button on the top corner of the
screen.
Figure 29 Splitter
13. To analyze/display the results, select on “Master property table” icon on the tool bar. A box
will appear which is double clicked to modify it further. Select the streams which have to be
shown in output and click “OK”. The property table will be opened showing all the results as
shown in the figure below.
Input Output 1 Output 2 Output 3
Temperature (K) 298.15 298.15 298.15 298.15
Pressure (Pa) 500000 500000 500000 500000
Mass Flow (kg/s) 0.025 0.00833333 0.00833333 0.00833334
Molar Flow (mol/s) 1.38771 0.46257 0.46257 0.462571
Volumetric Flow 2.50906E- 8.36353E- 0.00215098 0.00215099
(m3/s) 05 06
Density (Mixture) 996.389 996.389 3.87419 3.87419
(kg/m3)
Molecular Weight 18.0153 18.0153 18.0153 18.0153
(Mixture) (kg/kmol)
Specific Enthalpy -2440.55 -2440.55 -151.963 -151.963
(Mixture) (kJ/kg)
41
Flow Split with Splitter 27 August 2022
By Viraj Desai, Process Engineer
42