24VPHM-PID-001/03 PI-2914 15 NB

24VPHM-PID-001/05 PI-2085 15 NB
24VP00-PID-001/02 PI-1913 15 NB 24VPHM-PID-001/07 PI-2180 15 NB
24VP00-PID-001/03 PI-1922 15 NB
24VP00-PID-001/04 PI-1933 15 NB
24VP00-PID-001/05 PI-1943 15 NB

26SA00-PID-001 26SA00-PID-001
PI-2914 DN25-SBN-PP ( PI-6003) PI-2912 DN25-SBN-PP ( PI-6003)
15 NB 15 NB

24VPHM-PID-001-21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 24 VP 00 11-B1-01 L
TCWS Drain Tanks Upper Level EJ-1001 To PST (TA-0601)
24VPHM-PID-001/12 PI-1711 PI-1615 24VPHM-PID-001/03
16E 1H
24VPHM-PI-2725 DN25 DN50 24VP00-PI-1615
VG-1711 N1 N2
N2 Motive Gas N3 HMS-03

N2 Inert & Purge FA-1001


K K
24VPHM-PID-001/12
PI-1014 PI-1015
16C
24VPHM-PI-2702
DN150
VG-1701 VG-1015 OP23(TA-0001) DN150/100 DN100/50

11-B2-01 BIG BIG BIG BIG BIG BIG BIG BIG BIG BIG
TCWS Drain Tanks 1013 1012 1011 1010 1014 1015 1016 1017 1018 1019
24VPHM-PID-001/11 Note: 3

Note: Inspection opening


16I Vent & Evacuation

Leak pressure detection


24VPHM-PI-2803 MT
VG-1801 MT 24VP00-PID-001/03

DN100/40
1018 14I
DW Filling & Cleaning 24VP00-PI-1610
J 1017 J

DN80/50
ML MLH VG-1610

Skirt
MP MPH MPH
1011 MTW 1012
1013 1012 MTW 1011
1018
1017
Spare Spare

Note: 2
N30.2
N14 N19 N38.1
N37.1 N37.2 N38.2 N32
N16 N33 N30.1 OP01
PI-1802

N18 N24
N02.1 N01.1 DN80 MP MP
1014 1015

I I

DN80/40
TA-0001
N22 Small LOCA Tank (SLT)
VG-1802 VST-1
From HMS OFT

Point
High
(24VPHM-TA-0606)
PI-1803

DN50/25
24VPHM-PID-001/07
16D
H 24VPHM-PI-2036
DN25 DN50 N15 H
N35
Spare
MPG
N36 1602
24VPRP-PID/03 Spare
14F
24VPRP-PI-1017 N13
VR-1001
MZH
Expansion Vessel
1001
TA-1602

G MZL ML ML G
1001 1015 1014

DN25
N04
MT MTW MTW MT PI-1602
1015 1015 N06 1016 1016
DN25
VG-1602
PI-1011 N07.2
N07.1
DN50

F MTH MTW F
1014 1014 N03.1
VG-1803 N05.1 MTW MTH
1011 1011

PI-1012
MTH MTW
N03.2 MTW MTH
1013 1013 N05.2
1012 1012

N03.3

N05.3

E E
PI-1011
DN50

Man hole
DN600

N17 MP MP
1016 1017
Drainage
PI-1912 PI-1910 24VPHM-PID-001/10
1J
DN80 DN65 24VP00-PI-1910
N01.2 N02.2 DN80/65 15NB VG-1901
Skirt

24VPHM-PID-001/21 Drainage
MT PI-1911
D 1019 24VP00-PI-1913 1K
24VPHM-PID-001/10
D
N11.1 DN25 24VP00-PI-1911
VG-1911
MP MFT MPD NOTE: Connection
1023
1022 1013 for Skirt drainage
from N11.2,N11.3
PI-1013
Actuated Valve
DN50
26CH H2 24VP00 N02 N01 N02 N01 VG-1012
HX-0001 24VP00 26CH H2

VG-1980
MFT PL-0001

LC
MP

DN25
1014
1018
C CHWS H2 Inlet CHWS H2 Outlet C
PI-1501 PI-1502
24VP-26CH-001-IP-05 24VP-26CH-001-IP-06
DN25
DN25
DI-1014

Notes:
1: Inspection opening Leak pressure detection
2: N24.1 ~N24.10 for Igniters BIG1010~BIG1019
B 3: BIG1010~BIG1013 are Spark type, BIG1014~BIG1017 are glow type and BIG1018~ BIG1019 are passive Ignitors B
4: Bellow sealed gate valves are use on pipelines potentially exposed to tritium.
Uncontrolled Once Printed

SHEET TITLE:

24VP00-PID-001/02
DIAGRAM TITLE:

24VP00-PID-001
VVPSS
SMALL LOCA TANK TA-0001
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
24VP00 PID 18-11-2020 __ A1
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

4CSLSL EXTERNALREF 1 1.1


2/5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 24 VP 00 L

11-B1-01 To HMS PST


N2 Motive Gas TCWS Drain Tanks Upper Level EJ-1002 (24VPHM-TA-0601)
24VPHM-PID-001/12
PI-1721 PI-1721 PI-1026 24VPHM-PID-001/03
16E 1J
24VPHM-PI-2726 DN25 DN50 24VPHM-PI-2001
DN25 N2
VG-1721 N1
DN25 N3 HMS-02 / -03

VG-1723
From LLT-3 (TA-1004)
K 24VP00-PID-001/05 PI-1046 K
16K
24VP00-PI-1046 DN50

From LLT-2 (TA-1003)


PI-1024 PI-1025 24VP00-PID-001/04
PI-1036
16K
DW cleaning/spray DN150 DN150 24VP00-PI-1036 DN50
24VPHM-PID-001/11
VG-1025 DN150/100 DN100/50
16J
24VP00-PI-1824 FA-1002
VG-1824

BIG BIG BIG BIG BIG BIG BIG BIG BIG BIG
J PI-1027 J

DN100/40
1027 1026 1025 1024 1020 1021 1022 1023 1028 1029
Emergency Vent to
DN150 Drain Tank Room
VG-1027 VG-1127
Vent & Evacuation
N2 Inert and Purge
PI-1720 PI-1601 24VPHM-PID-001/13
24VPHM-PID-001/12 2H

DN100
16C MT MT DN50 24VP00-PI-1601

DN80/50
24VPHM-PI-2703 DN25 1027 1028
VG-1720 ML MLH
MPH VG-1620
1021
1021 1022 Note 1
MTW MTW

Note 2
MP MPH
1023 1022 1027 1028 N30.2

I N23 N14 I
N37.1 N37.2 N38.1 N38.2 N19 N30.1
N18
N24 N16
MP MP 24VP00-PID-001/02
PI-1610
16J
PI-1825

N02.1 N01.1 1024 1025 24VP00-PI-1610 DN50

24VP00-PID-001/04
PI-1630
16J
24VP00-PI-1630 DN50

DN80/40
H H
TA-0002
DN80 N22 Large LOCA Tank 1
VG-1825

N35
Spare

N36
Spare
G G

24VPRP-PID/03
PI-1020 ML ML
14J 1025 1024
24VPRP-PI-1020 DN0-PT-Undefined N13

F F

MT MTW N04 MTW MT


1025 1025 N06 1026 1026

MTH MTW N03.1 MTW MTH


1024 1024 N05.1 1021 1021

E MTH MTW N03.2 MTW MTH E


1023 1023 N05.2 1022 1022

N03.3
N05.3

MP MP
Man hole

D D
DN600

1026 1027
Drainage
PI-1921 PI-1920 24VPHM-PID-001/10
1I
DN80 N01.2 N02.2 DN65 24VP00-PI-1920
DN80/65
VG-1920
24VPHM-PID-001/21
skirt

15NB
24VP00-PI-1922

C Actuated Valve C

B B

Notes:
1. Inspection opening Leak pressure detection
Uncontrolled Once Printed

SHEET TITLE:

2: N24.1 ~N24.10 for Igniters BIG1020~BIG1029 24VP00-PID-001/03


3: BIG1020~BIG1023 are Spark type, BIG1024~BIG1027 are glow type and BIG1028~ BIG1029 are passive Ignitors DIAGRAM TITLE:

4: Bellow sealed gate valves are use on pipelines potentially exposed to tritium. 24VP00-PID-001
VVPSS
LARGE LOCA TANK TA-0002
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
24VP00 PID 18-11-2020 __ A1
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

4CSLSL EXTERNALREF 1 3/5


1.1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 24 VP 00 11-B1-01 L
TCWS Drain Tanks Upper Level

Motive N2 EJ-1003
24VPHM-PID-001/12 PI-1731 PI-1731 24VP00-PID-001/03
16F 14K
24VPHM-PI-2727 DN25 24VP00-PI-1036
DN25 N2
N1
N3
To PST

DN50
DN15
K PI-1034 PI-1035 K
DN150 DN150 DN100
VG-1035 DN150/100 DN100/50

FA-1003

PI-1037
DN150
DW cleaning/spray
24VPHM-PID-001/11 PI-1834
16J
24VP00-PI-1834
Emergency Vent to
DN40
VG-1834 Drain Tank Room
Note 3 VG-1037 VG-1137

DN150
J J
BIG BIG BIG BIG BIG BIG BIG BIG BIG BIG
1035 1034 1033 1032 1031 1030 1036 1037 1038 1039 Vent & Evacuation
N2
PI-1630 24VP00-PID-001/03
PI-1730

DN100/40
24VPHM-PID-001/12 14H
16D DN50 DN50 24VP00-PI-1630
24VPHM-PI-2721 DN25 VG-1630
VG-1730 MT MPH

DN80/50
MT 1038 1031
MP MPH
1033 1032
1037 MLH Vent & Evacuation
ML
1032 24VP00-PID-001/05
PI-1640
1031 MTW Note 1 16J

PI-1632
MTW 24VP00-PI-1640 DN50

Note 2
1038
1037

DN100
N30.2
I I
N32 N33 N23 N14
N37.1 N37.2 N38.1 N38.2 N19 N30.1
N24
PI-1835

N16
N18 MP MP
DN40

N02.1 N01.1 1034 1035

PI-1631
DN15

H H
TA-0003
N22 Large LOCA Tank 2
VG-1835

N35
Spare

N36
Spare
G G

24VPRP-PID/03
PI-1030 ML ML
14H
24VPRP-PI-1030 N13 1035 1034
DN300

F F

MT MTW N04 MTW MT


1035 1035 N06 1036 1036

MTH MTW N03.1 MTW MTH


1034 1034 N05.1 1031 1031

E N03.2
E
MTH MTW MTW MTH
1033 1033 N05.2 1032 1032

N03.3
N05.3

D D
Man hole

MP MP
DN600

1036 1037
Drainage
PI-1932 PI-1930 24VPHM-PID-001/10
1H
DN80 N01.2 N02.2 24VP00-PI-1930
DN80/65 VG-1930
Skirt

24VPHM-PID-001/21
15 NB
24VP00-PI-1933

C C
Actuated Valve

B B
Uncontrolled Once Printed

SHEET TITLE:

24VP00-PID-001/04
Notes: DIAGRAM TITLE:

1: Inspection opening Leak pressure detection 24VP00-PID-001


2: N24.1 ~N24.10 for Igniters BIG1030~BIG1039 VVPSS
3: BIG1030~BIG1033 are Spark type, BIG1034~BIG1037 are glow type and BIG1038~ BIG1039 are passive Ignitors
4: Bellow sealed gate valves are use on pipelines potentially exposed to tritium. LARGE LOCA TANK TA-0003
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
24VP00 PID 18-11-2020 __ A1
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

4CSLSL EXTERNALREF 1 4/5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels
11-B1-01
L 24 VP 00 TCWS Drain Tanks Upper Level
L

N2 Motive Gas EJ-1004 To PST


24VPHM-PID-001/12 PI-1741 PI-1046 24VP00-PID-001/03
16F 14K
24VPHM-PI-2728 DN25 DN50 24VP00-PI-1046
VG-1741 N1 N2
N3

PI-1742 VG-1742

DN50
K K
PI-1045
DN150 DN100
DN150/100 DN100/50

PI-1045
DN15

DN150
FA-1004
N2
PI-1740 PI-1044 PI-1047
16D
24VPHM-PID-001/12 Emergency Vent to
24VPHM-PI-2723 DN25 DN150 DN150 Drain Tank Room
VG-1740 VG-1045 VG-1047 VG-1147

J PI-1804 J
24VPHM-PID-001/11
16K
24VP00-PI-1804
BIG BIG BIG BIG BIG BIG BIG BIG BIG BIG
DW cleaning/spray

Skirt
1043 1042 1041 1040 1044 1045 1046 1047 1048 1049 Vent & Evacuation
11-B2-01 PI-1640 PI-1640 24VP00-PID-001/04
TCWS Drain Tanks Note 3 MT 14I
VG-1804 1047
MT DN50 24VP00-PI-1640
1048 MPH VG-1640
ML

DN80/50
MLH Note 1 1041

Note 2
MP MPH 1041
MTW 1042 MTW
1043 1042
1047 1048 N30.2

N33 N23 N14


PI-1805

I N32 I
N24 N16 N37.1 N37.2 N38.1 N38.2 N19 N30.1 PI-1640
N18
N02.1 N01.1 DN80
MP MP
1044 1045

DN80/40
H PI-1805 TA-0004 H
DN80 N22 Large LOCA Tank 3
VG-1805

N35
Spare

N36
Spare
G G

24VPRP-PID/03
PI-1040 ML ML
14J 1045 1044
24VPRP-PI-1040 DN300 N13

F F

MT MTW N04 MTW MT


1045 1045 N06 1046 1046

MTH MTW N03.1 MTW MTH


1044 1044 N05.1 1041 1041

MTH MTW N03.2 MTW MTH


E 1043 1043 1042 1042
E
N05.2

N03.3
N05.3
Man hole
DN600

MP MP
D 1046 1047
Drainage D
PI-1942 PI-1940 24VPHM-PID-001/10
1G
24VP00-PI-1940
DN80 N01.2 N02.2 15 NB
DN80/65 VG-1940 24VPHM-PID-001/21
Skirt

Drainage
24VP00-PI-1943
N11.1 PI-1941 24VPHM-PID-001/10
1I
DN25 24VP00-PI-1941
VG-1941
NOTE: Connection
for Skirt drainage
C C
from N11.2,N11.3
Actuated Valve

B B
Uncontrolled Once Printed

SHEET TITLE:

24VP00-PID-001/05
Notes: DIAGRAM TITLE:

1: Inspection opening Leak pressure detection 24VP00-PID-001


2: N24.1 ~N24.10 for Igniters BIG1040~BIG1049 VVPSS
3: BIG1040~BIG1043 are Spark type, BIG1044~BIG1047 are glow type and BIG1048~ BIG1049 are passive Ignitors
4: Bellow sealed gate valves are use on pipelines potentially exposed to tritium. LARGE LOCA TANK TA-0004
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
24VP00 PID 18-11-2020 __ A1
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

4CSLSL EXTERNALREF 1 5/5


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 24 VP HM 11-B1-01 Drain Tank Room(DTR) L


P TCWS Drain Tanks Upper Level
11-B2/B1-01
24VPHM-PID-001/11 PI-2814
16G
24VPHM-PI-2814
DN40
DW water cleaning/spay 24VPRP 24VPHM

S S To PAR (TA-0602)
PI-2013 PI-2003 24VPHM-PID-001/04
1K
K DN100 DN150 24VPHM-PI-2003 K
VG-2013 VG-2113 H2 H2 MP
MPH MPH MAM MAM MTE 2002 MPD MP MFT
2002 2012 2102 2002 2004 2002 2102 2004
SLT by-pass S S
24VPRP-PID/03
PI-2083
14E
24VPHM-PI-2002 DN100 DN100
HMS-01 VG-2002 VG-2102
H H 24VPRP 24VPHM
MP MPD MTE MFT
2004 2004 2001 2003
LLT vent line L S

24VP00-PID-001/03
PI-2001
J 16K
24VP00-PI-1026
J
DN80 16G
24VPHM-PID-001/12
HMS-02 (LLT venting) VG-2001 24VPHM-PI-2724

VK-2001

VK-2002

PI-2724

PI-2086
HMS-03 (from LLT) Note 5

DN25

DN15
S

Note 4

VG-2723

VG-2086
LC
Sampling return to QEN (TA-0603)
PI-2008

N5 BIG PI-2084 24VPHM-PID-001/05

LC
MTE MP MPD MFT MFT N1 2001 1K
A IGN

100/40
24VPHM-PI-2084

80/22
2007 2003 2003 2001 2002 DN15
S
This Part is to be removed
BIG N1 N2
Air supply PI-2007 Sampling from QEN (TA-0603)

DI-2001

DI-2002
Note 7 N2
B 2002
IGN PI-2085
I From DTR N5 24VPHM-PID-001/05 I
DN100 TA-0631 N6
16J
24VPHM-PI-2085
VG-2007 VK-2007 N3 BIG DN15

40/100
Compressed Air train A

22/80
N4

VG-2816
2003
(PIC CA) S IGN Sampling return to OFT (TA-0606)
N2 SFU-0641
PI-2402 PI-2181

SMI-2001
24VPHM-PID-001/18 24VPHM-PID-001/07
15G 1J

PI-2001

PI-2083
24VPHM-PI-2402 DN20 N7 24VPHM-PI-2181
DN15
VG-2412 N8
24VP00 24VPHM MTE TA-0621 Sampling from OFT (TA-0606)
2112
N1 N3 N4 PI-2180 24VPHM-PID-001/07
16J
N2 24VPHM-PI-2180

VG-2815

VG-2081
PI-1615 PI-2012 DN15

DE-2001
24VP00-PID-001/02
16L
24VP00-PI-1615 DN50 DN50
H H

VG-2082
VG-2012

LC

LC
HMS-03 (from SLT) MT ML MP
15 NB MFT
N1 TA-0611 2008 2001 2001
2006
S

DN15

LC
N2 N15 15 NB 24VPHM-PID-001/21
24VPHM-PID-001/12
PI-2711 PI-2917 DN15 MPD
16G
24VPHM-PI-2711 DN25 N01 N03 N07 T02 L01
2003 29VPHM-PI-2914
N02 P01 To QEN (TA-0603)
VG-2711 L03
N04 N05 N13
N14
N06 P02 PI-2917
N16 MPD 24VPHM-PID-001/05
S 1I
PIC-N2 safe purge 2005

DN15
DN15 24VPHM-PI-2004

DN15
TA-0601 DN50

DN100
PI-2722 DN50/25
16K
24VPHM-PID-001/12
Note 6 SP-0005 SP-0007 Actuated Valve
G
24VPHM-PI-2722 DN25
VG-2721 SP-0006
(PST) h1 G
N17 PI-2005
11-B2-01 Note 3

DN0
TCWS Drain Tanks DN25

DN0
MP MTH MTW

VG-2903
2007 2104 MTW MTE
2104 T04

LO
T01 2002 2002

F MTH MTW SP-0002 F


2105 2105 T03

DN15

PI-2903
PI-2005
DN25
MR
VG-3224

2001

gamma detector SP-0001


LC

CHWS-H1 train A from HX-0008 LO


PI-3220 N08

VG-3241
24VPHM-PID-001/08
1J
24VPHM-PI-3220 DN65
E VG-3225 E
HX-0010

LC
HX-0010 LO
CHWS-H1 train A return
VG-3324

SP-0004 PI-3240 24VPHM-PID-001/14


1I
DN65 DN65 24VPHM-PI-3240
N10
VG-3240
LC

CHWS-H1 train B from HX-0008 LO


24VPHM-PID-001/08 PI-3320 N09
SP-0003
16K

VG-3341
24VPHM-PI-3320 DN65
VG-3325
HX-0011
HX-0011

LC
PI-3330

LO
CHWS-H1 train B return
DN65

PI-3340 24VPHM-PID-001/14
1E
D N11 DN65
24VPHM-PI-3340 D
VG-3340
PI-3230

LP
N2 P
DN65

24VPHM-PID-001/12
PI-2707
16I
24VPHM-PI-2707 VG-3330 VG-3331
DN25
VG-2707 N12

DN65/25
DN65/25
DN65
LP

DW

DN65
P P To drainage distribution
VG-3230 VG-3231 DN65/40
PI-2907
C 16H
24VPHM-PID-001/11
1E
24VPHM-PID-001/10 C
24VPHM-PI-2810 DN40 DN65 24VPHM-PI-2907
VG-2810 Note 1
P To drainage distribution
24VPHM-PID-001/10
1C
24VPHM-PI-2904
VG-2904 VK-2904

PI-2904
DN50
B B
NOTES:
1. Swept TEE to be used
2. Fire protection to be applied for whole process system up to isolation valve
Uncontrolled Once Printed

MLH SHEET TITLE:

2003
3. Vertical height h1 of overfilling line is related to the differential pressure between PST 24VPHM-PID-001/03
DIAGRAM TITLE: 2.1
and QEN head space pressures during operation (ca. 5 kPa => h1 ≈ 0.5 m) 24VPHM-PID-001
4. Igniters; BIG-2001 and BIG-2002 are sparking type, BIG-2003 is passive type BA-0001
Hydrogen Mitigation System
5. Injection of reagents for conditioning/treatment of TA-0601/-0603/-0606 via SFU-0641
6. Fire resistant thermal insulation with vapour barrier to avoid condensation at cold Pool Scrubber Tank
A outer tank walls and risk of water accumulation in the bund (BA-0001) PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size:
STATUS:
A
7. PIC1-A sensors are integrated with a 2oo3 architecture per train 24VPHM PID 26/06/2019 __ A1
8. Bellow sealed gate valves are use on pipelines potentially exposed to tritium. IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

X27VGJ EXTERNALREF . 3/
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
unset
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 24 VP HM 11-B2-01 L
TCWS Drain Tanks Process gas outlet to Wet
Sampling return from Sampling
Station (SFU-0641) Recombiner
LC
24VPHM-PID-001/03 PI-2084 PI-2029 24VPHM-PID-001/06
16I 1J
24VPHM-PI-2084 24VPHM-PI-2029
This PartDN15
is to be removed
DN150
VG-2084

PI-2094

PI-2095
DN25

DN25
NG P

24VPHM-PID-001/12
K 16J
24VPHM-PI-2704
K

VG-2094

VG-2095
LC

LC
NOTE 3
DW P
24VPHM-PID-001/11
PI-2802 24VPHM-PID-001/21
16F
24VPHM-PI-2802 DN40 To Sampling Station (SFU-0641)
LC
PI-2085 24VPHM-PID-001/03
16I
24VPHM-PI-2085
VG-2085

PI-2085
J J

DN15
DN50/40
from PAR (TA-0602)
24VPHM-PID-001/04
PI-2016
16C
24VPHM-PI-2016

DN50/25
DN150
Process gas inlet
Actuated Valve

I I

DN50
From PST(TA-0601)
24VPHM-PID-001/03
PI-2004
16G
24VPHM-PI-2004

Water overfilling line ML MT MP


2023 2021 2021
PI-2905 MPD
2021
N07 N02 N05 N09 N03 N08
N01

PI-2905
L01

DN15
T02

DN15
N06
H P01 H
MPD
2022
SP-1006

TA-0603
(QEN) to OFT (TA-0606)
PI-2035
24VPHM-PID-001/07
1I
G 24VPHM-PI-2035 G
h1 DN50
Overflow Line

N04 NOTE 4

T01 MTW MT
F F
SP-1009 2022 2022

DN25
SP-1010
MR
2021

Gamma

DN15
E detector E

N10

D D
PI-2906

N2
DN65

P
24VPHM-PID-001/12
16J
24VPHM-PI-2708
VG-2708 VK-2708

DN65/25
P To drainage distribution
DW P DN65/40
24VPHM-PID-001/11
PI-2906 24VPHM-PID-001/10
16F 2D
24VPHM-PI-2811 24VPHM-PI-2906
C VG-2811 DN65
C
NOTE 1

B B
NOTE:
1. Swept TEE to be used
2.Fire protection to be applied for whole process system
Uncontrolled Once Printed

SHEET TITLE:
up to isolation valve
24VPHM-PID-001/05
3. For commissioning/testing (bypass, gas analysis) DIAGRAM TITLE: 2.1
4. Vertical height h1 of overflow line is related to the 24VPHM-PID-001
differential pressure between the QEN and the OFT
headspaces during operation HYDROGEN MITIGATION SYSTEM
5. Bellow sealed gate valves are use on pipelines Quencher Tank
potentially exposed to tritium.
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
24VPHM TO BE __ A1
IO REFERENCE: FULFILLED
EXTERNAL REFERENCE: VERSION: Sheet N°:

IDM_NUM EXTERNALREF . 1.12


5/20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 24 VP HM L

11-B2-01
TCWS Drain Tanks

Gas / Liquid inlet from


Wet Recombiner Gas outlet to EXC
24VPHM-PID-001/06
PI-2100 PI-2078 24VPHM-PID-001/08
16C 1F
24VPHM-PI-2100 DN200 DN150 24VPHM-PI-2029
K VG-2078 K

P
DW 24VPHM-PID-001/21
24VPHM-PID-001/11 PI-2807 To Sampling Station
16E
24VPHM-PI-2807 DN40 LC
(SFU-0641)
VG-2807 PI-2180 24VPHM-PID-001/03
16H
24VPHM-PI-2180
Return from Sampling DN15 DN15
Station (SFU-0641) VG-2180

16I
24VPHM-PID-001/03
LC
This Part is to be removed PI-2181
24VPHM-PI-2181 DN15
J J
VG-2181
Actuated Valve
Condensate from EXC
24VPHM-PID-001/08
PI-2017
16D
24VPHM-PI-2017 DN25

Water overflow from MT ML MP


P 2034
QEN (TA-0603) 2032 2031
24VPHM-PID-001/05 PI-2035
I 16G MPD I
24VPHM-PI-2035 DN50
N01 DN15 2036
VG-2035 N09 N02 N05 T01 L01
N06

PI-2105
N08
P01
N03

DN200
SP-1010

DN15
MPD
2035

H H

TA-0606

G G

DN15

PI-2105
DN15
F F
MT MTW
2031 2031
T02
MFT
2103
To Wet Recombiner
MR PI-2103 24VPHM-PID-001/06
2031 1I
24VPHM-PI-2103
DN25
Gamma
detector
E E

N07
P
NG
24VPHM-PID-001/12 MFT

PI-2101
16K
24VPHM-PI-2709 2036
VG-2709 VK-2709 S
24VPHM 24VP00
PI-2036 24VP00-PID-001/02
1H
=1610632721/2247
PI-2709

DN25
DN25

VG-2101 VG-2036 VK-2036


To SLT (TA-0001 / VST-1)
D D

PI-2103
P
MP
2116
P
DW
24VPHM-PID-001/11 PI-2812 PI-2812 PI-2103
16D
24VPHM-PI-2812 DN40
DN40
VG-2812 VK-2812 DN50/40 DN50 DN25
To drainage distribution
VG-2104 VK-2116 VG-2117
24VPHM-PID-001/10
1E
PL-0616 24VPHM-PI-2902
VG-2902

MP
2126
C C
PI-2104
DN50 DN25
VG-2114 VG-2126 VG-2127
PL-0626

PI-2902
DN50
B VK-2902 B
Uncontrolled Once Printed

SHEET TITLE:

24VPHM-PID-001/07
DIAGRAM TITLE: 2.1
24VPHM-PID-001
HYDROGEN MITIGATION SYSTEM
NOTES: OVERFLOW TANK (OFT)
1.Fire protection to be applied for whole process system
A PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
up to isolation valve STATUS:

2. Bellow sealed gate valves are use on pipelines 24VPHM PID 26/06/2019 __ A1
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:
potentially exposed to tritium.
X27VGJ EXTERNALREF . 1.12
7/20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1 v3.2
ITER_D_PF8GUB 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PBS 3 levels

L 26 SA 00 L

11-L4-04 14-L4-21
TCWS VR-9002 Vault Annex (PHTS drainage and Drying System)

SBL SBM VR-0005


PI-9003 CHX SBM

SBM
K
DN15-SBL-PP
26SA00-PID/09
PI-6035 K
MP MP 16D

SBL
26SA00-PI-6035 DN15-CHX-XX

SBL SBM
0002 0012

VG-8000

VG-8001
SAMPLING SYSTEM
CONFINEMENT VESSEL

DN15-SBL-PP
PI-9002
MT
0002 26SA00-PID/09
PI-2404
16G

DN15-SBL-PP

DN15-SBL-PP
PI-8000

PI-8001
26SA00-PI-2404
NOTE 8 MTW DN15-SBN-XX

26SA00-PI-0007
SBN

26SA00-PID/09
0002

DN15-SBL-XX
PI-0005
VG-6001
EEL SBM SBM SBL SBL SBM SBM SBL SBL SBM SBL
IBED PHTS PZR

SBL
J 26PHBD-PID/03
26PHBD-PI-4800 PI-6100 PI-6000 PI-6000 PI-0002 PI-0004 J
7B
26PHBD-PI-4800 DN15-EEL-HC DN20-SBL-HC DN25-SBL-PP DN25-SBL-PP N2 N1 DN15-SBL-PP DN15-SBL-PP
DN25/20 NOTE 9 NOTE 9 NOTE 9
VG-6000 NOTE 10 VK-0002

26SA00-SEP-0900
VG-6100

DN15-SBL-XX
PI-6001
MT MT MT 1E
PL-0002 0025 SAMPLE COOLER 0005 0015
MTW FOR GRAB MTW MTW
NOTE 8 SBN SBM SBL 0025 0005 0015
SBL SBM SBM SBL
HX-0005
EKL SBM SBM SBL SBL SBM SBM SBL PI-0001 N2 N1 PI-0003
IBED PHTS PRT
26PHBD-PI-4802 PI-6113 PI-6013 DN15-SBL-PP DN15-SBL-XX
9B
26PHBD-PID/03 VK-0001 NOTE 11 VC-0003 NOTE 11 VK-0004

MFT-0004
26PHBD-PI-4802

NOTE 6
DN15-EKL-HC DN20-SBL-HC DN25/20 DN25-SBL-PP N3 N4 NOTE 5
I VG-6020 VG-6120 NOTE 1 I

DN10-SDQ-XX
PI-0007
NOTE 11

DN15-SBL-XX
PI-0003
SBL
26CCC1-PI-0002

26CCC1-PI-0001
DN40-GCL-PPF

DN40-GCL-PPF

SBM

VG-0004
11-B2-01
TCWS Drain Tanks VR-9000

SBM
MT
SBN SBP
H 0031 H
PI-9001

SBP
MTW

SDQ
NOTE 8 DN15-SBN-PP 0031
MP MP
NOTE 7 DPI-0001

SBN
SBP SBN SBN
ADT CCX SBP SBP SBP SBN
0001 0011 9J
26SA00-PID/06
10J
26SA00-PID/06

26DR00-PI-6004 PI-6109 26CCC1-PI-0002 26CCC1-PI-0001 NOTE 12

VG-8003

NOTE 2
26DR00-PID/05

VG-8002

DN15-SBN-PP
16F

PI-9000
26DR00-PI-6004 DN15-CCX-HC DN20-SBN-HC DN25-SBN-PP
DN25/20
VG-6013 VG-6039
MT

LEGEND

DN15-SBN-HC

VC-0004
L4 SLAB
DN15-SBN-HC
NOTE 8

PI-8003
PI-8002
6001
NOTE 9 PL-0001
MTW
G G
VVPSS:-
VV PHTS PRT AIX SBP SBP SBN SBN SBP SBP SBN
6001
26PHVV-PID/10
26PHVV-PI-6006 PI-0011
10C
26PHVV-PI-6006 DN15-AIX-HC N2 N1
DN25/20 DN25-SBN-PP DN15-SBN-PP
VG-6004 VG-6016 NOTE 10
M
NOTE 8 PI-2915
NDT1/SDT1
CDX SBP SBP SBN SBN SBP SBP SBN
(NORMAL OPERATION)
26DR00-PID/03 26DR00-PI-6003 PI-6108 24VPHM-PID-001/21 ,
7J 26DR00-PI-6003 DN15-CDX-XX DN20-SBN-HC DN25/20 DN25-SBN-PP
VG-6006 PI-2914
F Pump (Positive Displacement / F
NOTE 8 Centrifugal type)
NBI DT CGX SBP SBP SBN SBN
PI-6104
SBP SBP SBN
Copy same
26DR00-PI-6005
16B
26DR00-PID/04
valve
Not Connected

26DR00-PI-6005 DN15-CGX-HC DN20-SBN-HC DN25-SBN-PP DM Water Supply


arrangement
DN25/20

DN15-SDQ-XX
VG-6009
TO WCT

VG-6038
Line with actuated

PI-0010
Lower Pipe Chase N
Basement Gallery N

Upper pipe chase E


Here

26SA00-SEP-0900
Vertical Shaft V03

Vertical Shaft V03

TCWS Area East


NOTE 8
valve

Vertical Shaft V03

DN10-SDQ-XX
11-B2M-01N

PI-0008
11-B2-02N

11-L3-03E

11-L3-02E
11-L1-V03

11-L2-V03
-

11-B1-V03
E VV PHTS PZR AGX SBP SBP SBN SBN SBP SBP SBN
E
26PHVV-PI-6005 PI-6102
--

26PHVV-PID/10
11C
26PHVV-PI-6005 DN15-AGX-HCF DN20-SBN-HC DN25-SBN-PP
DN25/20
VG-6002
VG-6045
NOTE 8
SDT 1 (POST-
CDX SBP SBP SBN SBN SBP SBP SBN
ACCIDENT OPERATION)
26DR00-PID/07 26DR00-PI-6000 PI-6112
6I
26DR00-PI-6000 DN15-CDX-HC DN20-SBN-HC DN25-SBN-PP
DN25/20
VG-6015 VG-6041
PI-6015

D D
DN15-SBN-PP

NOTE 8

WCT-SIC2 CHX SBP SBP SBN SBN SBP SBP SBN

26SA00-PI-0008
26SA00-PID/09
26DR00-PID/10 26DR00-PI-6058 PI-6110
16D
26DR00-PI-6058 DN15-CHX-HC DN25-SBN-PP
DN20-SBN-HC DN25/20
24VPHM-PID-001/21 ,PI-2912 VG-6017 VG-6043
SBN

NOTE 8 SDN SBM SBM SDQ 1D

RETURN TO NDT 1 CJX SBP SBP SDN


C C
SDN

26DR00-PI-6001 DN20/15 PI-6011


26DR00-PID/03
PI-6011
1E
26DR00-PI-6001 DN15-CJX-HC DN15-SDN-XX DN15-SDN-XX
VK-6011 VG-6011
VG-6110

RELIEF TO WCT
26DR00-PID/13
26DR00-PI-7822 PI-6120 26SA00-PID/09
16F 16F

L4 SLAB
26DR00-PI-7822 DN15-CHX-XX 26SA00-PI-6120
DN15-CHX-HC
14-L3-23
TCWSsecondary cooling pipes
B B
Uncontrolled Once Printed

SHEET TITLE:

NOTE: 26SA00-PID/02
DIAGRAM TITLE:
6- COLIORIS TYPE MASSFLOW METER
26SA00-PID-001
1- THERMOSTATIC 3 WAY VALVE 7- CLOSURE PLATE AND GUARD PIPE WILL BE IMPLEMENTED AND TAGGED LATER
2- BACK PRESSURE VALVE 8- DN20/15 REDUCER IS INTEGRATED WITH BALL VALVE BODY GRAB SAMPLING FOR PRIMARY SIDE
3- BACK PRESSURE VALVE 9- THERMOWELL IS INTEGRATED WITH FLOW CHAMBER
10- IN-LINE FILTER FOR COMMISSIONNING TO PROTECT EQUIPEMENT __
4- EACH ISOLATION VALVE SHALL BE LOCATED NEAR CORRESPONDENG
A TANK (EX. VG-6000 SHALL BE NEAR IBED PHTS PZR) 11- TUBING CONNECTION TO INSTALL BYPASS LINE DURING FLUSHING PBS NODE: DOCUMENT TYPE: DATE OF ISSUE: DESGIN AGENCY DOCUMENT Sheet Size: A
STATUS:
5- EXCESS FLOW CHECK VALVE 12- HCC BETWEEN VG-0004 AND VG-6011 5PENETRATION AND VALVES INCLUDED 26SA00 PID 30/11/2021 __ A1
IO REFERENCE: EXTERNAL REFERENCE: VERSION: Sheet N°:

PF8GUB EXTERNALREF D 2/12


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17