Gurung 2014
Gurung 2014
a r t i c l e i n f o a b s t r a c t
Article history: Communal rainwater tank systems provide an alternative urban water supply solution for reducing
Received 25 July 2013 dependence on centralised water supply networks. Rainwater from household roofs is transported
Received in revised form through a gravity collection system and stored in a centralised communal tank before being treated and
23 October 2013
supplied back to homes through a reticulated pumping system. Literature on the design, life cycle costing
Accepted 6 December 2013
Available online 18 December 2013
and economies of scale of communal rainwater tank systems is currently limited. This study intends to
develop a methodology for the system design, assess the economies of scale of communal systems and
identify the main cost contributors for the total capital and life cycle costs. A methodology developed for
Keywords:
Urban water
this analysis is presented for the benefit of water professionals across the globe to support similar studies
Water demand management in their local regions. Housing layouts were developed, designed and costed for a flat topography and a
Cost contributors centralised storage and treatment scenario, ranging from 4 to 576 homes. An economic assessment was
System design then carried out using the net present value method (NPV). The results show that costs of storage and
Economies of scale treatment units are more influential for a group of households at lower scale, whilst the diseconomy of
Communal rainwater tanks scale of pipes is a major cost factor for higher scale of household groups. An optimal scale was observed
between 192 and 288 households and sensitivity analysis on the discount rate showed no changes within
this range. A basic analysis showed that topography of the land does influence overall NPV. However, the
influence factor depends on the nature of the slope, with costs varying for differing scenarios and further
work required to have a thorough understanding of its influence in final NPV.
Ó 2013 Elsevier Ltd. All rights reserved.
0959-6526/$ e see front matter Ó 2013 Elsevier Ltd. All rights reserved.
http://dx.doi.org/10.1016/j.jclepro.2013.12.020
T.R. Gurung, A. Sharma / Journal of Cleaner Production 67 (2014) 26e36 27
Estimate rainwater flows from roof areas into the collec- rainwater tank suppliers, installers and plumber. Also collect
tion pipes. data on electricity charges and other operation and on-going
Estimate the flows in collection pipes as per the layout for maintenance costs (labour and chemicals).
sizing. Design the gravity flow collection system based on 10. Conduct a life cycle costing (LCC) for financial analysis of
local design guidelines and topography. Consider if sump each housing layout for a selected analysis period using
wells will be required. Sump wells are smaller sized un- standard approaches (see Section 4.1). This should include
derground tanks which serve as interim storage before the capital, operation and maintenance and replacement costs
main storage tanks. If sump wells are not considered, the over the analysis period. Estimate the LCC per household for
communal rainwater tanks will have to be placed under- each housing layout and the contribution of various infra-
ground which sometimes can be very deep and thus can be structure components.
uneconomical to construct and operate (See Fig. 5). 11. Plot the graph of final costs (on a per household basis)
Check the depth of the invert level of the collection system against the total number of houses for the associated housing
at the communal tank location. If the depth is high, a sump development layouts to estimate optimal scale of communal
cum pumping system for lifting the rainwater to the stor- rainwater tank system for selected topography and housing
age tank will be required. The designer can check for the density as demonstrated in Fig. 9.
trade-off between collection system cost at various gradi-
ents and the cost of cluster rainwater tanks if laid under-
ground completely and associated pumping system. 3. Application of proposed methodology
Design the rainwater distribution system based on local
design guidelines. The methodology outlined has been applied to a hypothetical
9. Collect local cost data for pipes, pipe laying, rainwater tanks, development area in South East Queensland, Australia. Cost values
sump wells, pumps and treatment units by contacting local for individual components of the system are for December 2011
Fig. 5. Basic layout of rainwater treatment system e sump wells were incorporated where the depth of rainwater collection system is greater than 1.5 m.
potable water will be provided for by other sources (e.g. on site total number of occupants. The resulting equations,
water recycling facility). y ¼ 15.185x0.708 (R2 ¼ 0.9957) for occupancies of 1e55 and
The volume of potable water end usage varies substantially y ¼ 2.1424x0.203 (R2 ¼ 0.9957) for occupant numbers between 56
between regions (Beal et al., 2010) and as such, potable consump- and 610, were used to calculate peak flows for the different
tion details are required at the local level for the design of the household layouts. Beyond 610 people, the average of Beal et al.
communal rainwater system. Estimates of average daily water (2012) findings of 0.58 L/min/person was used as this was the
consumption were based on the South East Queensland Resident maximum population analysed under this study and there is un-
End Use Study (SEQREUS) (Beal et al., 2010) and is summarised in certainty as to what the trend may be beyond this population size.
Fig. 6.
The table in Fig. 6 also shows the potable water appliances used 3.2.3. Collection pipes
in the design of the communal system. Combined water con- As is standard practice, the street layout of the model housing
sumption of shower and bath appliances was taken for the shower development was used in the design of the pipe network layout.
usage and hot water for laundry system taken as 25% of total water Hydraulic analysis of the site at CDM showed that household
used for laundry (EBMUD, 2008). connectors from the down pipes to the rainwater collection system
limited flows into the system to 2 mm/5 min (Cook et al., 2012) and
3.2.2. Peak flows in distribution system the remaining flows diverted to the stormwater collection system.
Estimation of peak water demand is important in the design of Applying the Rational Method (DERM, 2007), with roof area esti-
pumps and pipes for a water distribution network. Although design mates of 220 m2 (obtained from Google Earth) and 100% connec-
guidelines outlining peak flow factors are available, Swamee and tivity to the system, and a recommended runoff coefficient of 0.875
Sharma (2008) stated that local information on flow re- for a pitched roof (Cook et al., 2012), resulted in a maximum flow
quirements will provide a much better indication of peak flow se- harvest of 0.00128 m3/s. Gravity rainwater collection pipes, which
lection. Hence, peak flow demands have been estimated from two convey roof waters to the storage tank, were sized using Manning’s
studies of diurnal pattern analysis in SEQ. Smart water metre data equation with polyvinyl chloride (PVC) as the chosen pipe material.
from Umapathi et al. (2013) and Beal et al. (2010) containing peak Manning’s roughness loss for the PVC material has a recommended
flow rates per person were obtained and plotted against the value of 0.01 (Rossman, 2010). A slope of 0.5% was used so as to
respective number of occupants. Adding a trendline to the plot obtain a minimum pipe full velocity of >0.7 m/s according to the
provided two expressions for peak flow rates with respect to the Queensland Urban Drainage Manual (QUDM) (DERM, 2007). A
minimum cover of 0.6 m was used at the start to determine pipe
depths for estimating costs. Swamee et al. (1987); and Sharma and
Swamee (2008) provide direct methods for sizing collection
systems.
Table 1
Main components and costs for the RWH system in this study.
Capital costs
Pipes (PVC) e indexed
75 mm $77.23/m 80 GCW (2008)
100 mm $110.24/m 80 GCW (2008)
150 mm $178.08/m 80 GCW (2008)
225 mm $269.24/m 80 GCW (2008)
300 mm $355.10/m 80 GCW (2008)
375 mm $472.75/m 80 GCW (2008)
450 mm $871.31/m 80 GCW (2008)
Pumps
Recirculation pumps $3380e$8420/unit 12 Supplier
Transfer pumps $1070e$1185/unit 12 Supplier
Sump pumps $1575e$2055/unit 12 Supplier
Additional pump equipment (e.g. lockable main isolator, circuit breakers, $3685e$5945/unit 50 Supplier
folded base, isolation valves)
Installation $1650/set e Supplier
Commissioning $660/set e Supplier
Tanks
Concrete tanks; storage and larger sized holding tanks, sump wells $717/m3 50 Supplier
Plastic tanks; smaller sized holding tanks $1177e$4046/unit 25 Supplier
Other capital costs
Excavation (indexed) $96.35/m3 e Rawlinsons Group (2011)
Manholes (indexed) $5550e$14,020/unit 50 GCW (2008)
Treatment system housing (indexed) $39,032/unit 50 CDM manager
Sand, carbon filter and UV $2500/unit 12 Supplier
Chlorine doser (tablet system) $1500/unit 12 Supplier
Ongoing costs
Maintenance
Sediment checks and cleaning (every 3 years) $370e$6500/3 years e Plumber
Gutters $40/house/annum e Plumber
Pumps $350/pump/annum e Plumber
Filters þ UV lamps $300/annum e Supplier
Chlorine doser $200/annum e Supplier
Operation
Electricity for pumps (transfer, recirculation and sump), UV system $0.2276/kWh e Energy suppliers
T.R. Gurung, A. Sharma / Journal of Cleaner Production 67 (2014) 26e36 33
Table 2
Cost factors for varying depths of pipes (GCW, 2008).
Fig. 7 showed the two categories of capital cost components Fig. 8. Breakdown of capital costs per household for a communal RWH system.
(pipes plus storage and treatment units) being the dominating
factors in influencing final NPV for the majority of housing layouts,
with cost distribution for both components not dropping below 5.3. Life cycle cost per household
30% beyond the 16 households scale. The cost weightages for both
storage and treatment systems are observed to decrease with Life cycle costing of a communal rainwater harvesting system on
increasing household layout, whilst contributions from pipes are an individual household basis is plotted in Fig. 9 and shows an
noted to rise. This can be attributed to increasing pipe laying costs, initial drop in the costs, falling sharply from the 4 homes to 96
along with a decrease in the costs of storage and treatment units as homes layout before flattening off between 192 and 288 homes.
shown in Fig. 8. Booker (1999) and Clark’s (1997) studies also noted similar trends
Progressively longer, deeper and larger pipes for increasingly where the curve flattens off and only small cost differences occur in
larger developments results in a diseconomy of scale, shown in this household range. The minimum cost of $10,150 per household
Fig. 8 and highlighted by Clark (1997). Storage tanks and treatment is observed to be in the 192 households’ layout. However, the dif-
units on the other hand are shown to have an economy of scale, ference in per household cost between layouts of 192 and 288
with bigger sized tanks decreasing in costs on a per kL basis that is households is very low (Fig. 9). Beyond the 288 homes layout, the
further compounded by minimal price changes in other costs (filter, costs start increasing, with the rise clearer after 288 households as a
UV, chlorination and pumps). Fig. 8 also shows that for lower result of the diseconomy of scale of pipe costs exerting a larger
number of households, below 96 dwellings, capital costs are influence on the total life cycle cost of the system.
influenced by the costs of the storage units and treatment units, Fig. 9 further shows the influence capital costs have over the
whilst beyond this household number, the pipe costs dominate. final individual household NPV with both graphs (Figs. 8 and 9)
This observation is in agreement with Booker (1999) and Clark following a similar trend; an initial sharp drop until 96 households
(1997), both of whom state that treatment costs are the dominant before smoothing off to reach its lowest level at 192 households and
factor for lower scale of connections with the diseconomy of pipes rising after this. This capital costs trend, when broken down further,
affecting higher scales. Although both studies by Booker (1999) and indicates that including and below 96 households, the costs of
Clark (1997) were carried out for greywater and wastewater storage and treatment units dominate, whilst beyond this number,
respectively, the results from this study showed similar observa-
tions for communal rainwater systems.
Fig. 7. Cost contributions for various components of communal RWH systems per
household. Fig. 9. Total NPV costs per household for communal RWH systems.
34 T.R. Gurung, A. Sharma / Journal of Cleaner Production 67 (2014) 26e36
pipes are the main costs drivers. Although ongoing costs are
included in the final NPV, their low contribution of 13e29% and
continuing economy of scale trend proves the minimal influence
they have over final cost values.
Table 3
Results of sensitivity analysis for discount rates based on OBPR (2007) recommendations (Units ¼ percentage change in costs).
Maintenance Operation Replacement Total costs Maintenance Operation Replacement Total costs
Table 4 Chong, M.N., Umapathi, S., Mankad, A., Sharma, A., Gardner, T., 2011. A Benchmark
Cost differences between flat and sloped topography. Analysis of Water Savings by Mandated Rainwater Tank Users in South East
Queensland (Phase 2). Urban Water Research Security Alliance, Brisbane, QLD.
Flat topo. Sloped topo. % Of original cost Technical Report No. 49.
(Original) (Adjusted) Clark, R., 1997. Water Sustainability in Urban Areas: an Adelaide and Regions Case
Study, Report Five: Optimum Scale for Urban Water Systems. Department of
Capital costs
Environment and Natural Resources, Adelaide, South Australia.
Pipes $4522 $3654 81% Cook, S., Tjandraatmadja, G., Ho, A., Sharma, A.K., 2009. Definition of Decentralised
Storage Units $3849 $3466 90% Systems in the South East Queensland Context. Urban Water Security Research
Treatment Units $177 $177 100% Alliance, Brisbane, QLD. Technical Report No. 12.
Total Capital Costs $8548 $7297 85% Cook, S., Sharma, A.K., Gurung, T.R., Chong, M.N., Umapathi, S., Gardner, T., Carlin, G.,
Ongoing costs Palmer, A., 2012. Performance of Cluster Scale Rainwater Harvesting: Analysis of
Maintenance $1149 $1080 94% Residential and Commercial Development Case Studies. Urban Water Security
Operation $325 $291 90% Research Alliance, Brisbane, QLD. Technical Report No. 68.
Replacements $128 $102 80% Cook, S., Sharma, A., Chong, M., 2013. Performance analysis of a communal resi-
Overall NPV $10,150 $8770 86% dential rainwater system: a case study in Brisbane, Australia. Water Res.
Manage.. http://dx.doi.org/10.1007/s11269-013-0443-8.
Department of Environmental and Resource Management (DERM), 2007. Queens-
land Urban Drainage Manual (QUDM), second ed., vol. 1. Queensland
Government.
Department of Infrastructure and Planning (DIP), 2008. Water Saving Targets. For
influence of cost components. Housing layouts containing 4 to 576 Councils, Plumbers, Builders and Developers. A Guide to the Queensland
homes were designed to assist in obtaining cost data for the asso- Development Code Part MP 4.2. Queensland Government.
Domènech, L., Saurí, D., 2011. A comparative appraisal of the use of rainwater
ciated components of the system. Results showed that capital costs
harvesting in single and multifamily buildings of the Metropolitan Area of
made up the largest contribution (>70%) to the system followed by Barcelona (Spain): social experience, drinking water savings and economic cost.
maintenance, operation and replacement costs. J. Clean. Prod. 19 (6e7), 598e608.
Households of more than 96 homes highlighted the diseconomy East Bay Municipal Utility District (EBMUD), 2008. Water Smart Guide Book: a
Water-use Efficiency Plan Review Guide for New Businesses. Oakland,
of scale prevalent in most pipe networks, whilst lower scale California.
dwellings were shown to be more affected by storage and treat- Fane, S.A., Ashbolt, N.J., White, S.B., 2002. Decentralised urban water reuse: the
ment unit costs. Optimal development sizes occurred between 192 implications of system scale for cost and pathogen risk. Water Sci. Technol. 46
(6), 281e288.
and 288 households, with minimum NPV costs calculated to be Ghisi, E., de Oliveira, S.M., 2007. Potential for potable water savings by combining
$10,150 per household. Sensitivity analysis of discount rates the use of rainwater and greywater in houses in southern Brazil. Build. Environ.
demonstrated that the optimal numbers of households is not 42 (4), 1731e1742.
Ghisi, E., Ferreira, D.F., 2007. Potential for potable water savings by using rainwater
necessarily influenced by this parameter, and hence market rates of and greywater in a multi-storey residential building in southern Brazil. Build.
interest and inflation, which is the source of uncertainty for the Environ. 42 (7), 2512e2522.
discount rates. Gold Coast City Council (GCCC), 2008. Gold Coast Planning Scheme Policies, Policy
11: Land Development Guidelines, Section 4: Water Reticulation e Design Re-
Topography of the surrounding land was shown to exert a sig- quirements. Gold Coast, QLD.
nificant influence on the NPV for communal systems. The study Gold Coast Water (GCW), 2008. Unit Rate Reviews e 2008. Gold Coast Water and
showed total costs dropped by 13% for a layout with a slope of 0.5%. Hyder Consulting, Gold Coast, QLD.
Hashim, H., Hudzori, A., Yusop, Z., Ho, W.S., 2013. Simulation based programming
However, in varying scenarios, the final NPV may rise as there may
for optimization of large-scale rainwater harvesting system: Malaysia case
be a need for further system components. study. Resour. Conserv. Recycl. http://dx.doi.org/10.1016/j.resconrec.2013.05.
001.
Imteaz, M.A., Ahsan, A., Naser, J., Rahman, A., 2011. Reliability analysis of rainwater
Acknowledgements tanks in Melbourne using daily water balance model. Resour. Conserv. Recycl.
56 (1), 80e86.
Imteaz, M.A., Ahsan, A., Shanableh, A., 2013. Reliability analysis of rainwater tanks
This research was undertaken as part of the Urban Water
using daily water balance model: variations within a large city. Resour. Conserv.
Security Research Alliance (UWSRA), a research collaboration Recycl. 77, 37e43.
between the Queensland Government, CSIRO, The University of Jenkins, G.A., 2007. Use of continuous simulation for the selection of an appropriate
Queensland and Griffith University. The authors would like to urban rainwater tank. Aus. J. Water Res. 11 (2), 231e246.
Maheepala, S., Coultas, E., Neumann, L., Sharma, A.K., 2013. Quantification of
acknowledge the UWSRA Director, Don Begbie, for his continual Regional Scale Water Quantity and Quality Implication of Rainwater Tanks in
support. We also thank David Hamlyn-Harris and Chris Tanner South East Queensland. Urban Water Security Research Alliance, Brisbane, QLD.
from Bligh Tanner Consulting Engineers for their valuable sug- Technical Report No. 104.
Mankad, A., Chong, M.N., Umapathi, S., Sharma, A.K., 2012. The Role of Physical and
gestions and for providing relevant data to conduct the analysis. Psychological Factors in Understanding Rainwater Tank Maintenance. Urban
We also wish to especially acknowledge and thank all the trade Water Security Research Alliance, Brisbane, QLD. Technical Report No. 64.
personnel for providing the relevant equipment cost data and Mitchell, G., Diaper, C., 2010. UVQ User Manual. CMIT Report No. 2005-282. CSIRO.
Available at: http://www.csiro.au/Outcomes/Water/Water-for-cities-and-
who chose to remain anonymous due to commercial towns/UVQ.aspx (accessed May 2012).
sensitivities. Newnan, D.G., Lavelle, J.P., Eschenbach, T.G., 2002. Essentials of Engineering Eco-
nomic Analysis, second ed. Oxford University Press, New York.
Office of Best Practice Regulation (OBPR), 2007. Best Practice Regulation Handbook.
References Australian Government, Canberra.
Office of Economic and Statistical Research (OESR), 2012. Population and Dwelling
Australian Bureau of Statistics (ABS), 2010. Environmental Issues: Water Use and Profile. Queensland Government, South East Queensland. Available at: http://
Conservation. Mar 2010. Available at: http://www.abs.gov.au/ausstats/abs@.nsf/ www.oesr.qld.gov.au/products/profiles/pop-housing-profiles-reg-planning/
mf/4602.0.55.003 (accessed May 2012). pop-housing-profiles-seq.pdf (accessed May 2012).
Australian Bureau of Statistics (ABS), 2012. 6427.0-Producer Price Indexes, Australia, Rawlinsons Group, 2011. Rawlinsons Construction Cost Guide for Housing, Small
Dec 2011. Available at: http://www.abs.gov.au/ausstats/abs@.nsf/mf/6427. Commercial & Industrial Buildings. Rawlhouse Publishing, West Perth.
0 (accessed February 2012). Rossman, A.L., 2010. Storm Water Management Model User’s Manual. Water Supply
Beal, C., Stewart, R., Huang, T.T., 2010. South-east Queensland Residential End Use and Water Resources Division. US Environmental Protection Agency, Cincinnati,
Study: Baseline Results e Winter 2010. Urban Water Research Security Alliance, Ohio.
Brisbane, QLD. Technical Report No. 31. South East Queensland Water Grid Manager (SEQWGM), 2010. Submission to
Beal, C., Sharma, A., Gardner, T., Chong, M., 2012. A desktop analysis of potable Productivity Commission. Australia’s Urban Water Sector. November 2010.
water savings from internally plumbed rainwater tanks in South East Queens- Sharma, A.K., Swamee, P.K., 2008. Design methods for circular and non-circular
land. Water Res. Manage. 26, 1577e1590. sewer sections. J. Hydraul. Res. eIAHR 46 (1), 133e142.
Booker, N., 1999. Estimating the Economic Scale of Greywater Reuse Systems. Swamee, P.K., Bhargava, R., Sharma, A.K., 1987. Noncircular sewer design. J. Environ.
Program Report FE-88. CSIRO Molecular Science. Eng. ASCE 113 (4), 824e833.
36 T.R. Gurung, A. Sharma / Journal of Cleaner Production 67 (2014) 26e36
Swamee, P.K., Sharma, A.K., 2008. Design of Water Supply Pipe Networks. John Walton, A., Gardner, J., Sharma, A.K., Moglia, M., Tjandraatmadja, G., 2012. Exploring
Wiley & Sons, New Jersey. Interventions to Encourage Rainwater Tank Maintenance. Urban Water Security
Umapathi, S., Chong, M.N., Sharma, A.K., 2013. Evaluation of plumbed rainwater Research Alliance, Brisbane, QLD. Technical Report No. 59.
tanks in households for sustainable water resource management: a real-time Ward, S., Memon, F.A., Butler, D., 2010. Rainwater harvesting: model-based design
monitoring study. J. Clean. Prod. 42, 204e214. evaluation. Water Sci. Technol. 61 (1), 85e96.
Vieritz, A., Gardner, T., Baisden, J., 2007. Rainwater TANK model designed for use by Ward, S., Butler, D., Memon, F.A., 2012. Benchmarking energy consumption and CO2
urban planners. In: Proceedings of Ozwater 2007 Convention & Exhibition. 4e8 emissions from rainwater-harvesting systems: an improved method by proxy.
March 2007. Australian Water Association, Sydney. Water Environ. J. 26 (2), 184e190.