Professional Documents
Culture Documents
A Textbook of Power Plant Engineering 5ed R. K. Rajput 2016
A Textbook of Power Plant Engineering 5ed R. K. Rajput 2016
POWER PLANT
ENGINEERING
IN
SI UNITS
For
By
Er. R.K. RAJPUT
M.E. (Hons.), Gold Medallist; Grad. (Mech. Engg. & Elect. Engg.) ;
M.I.E. (India) ; M.S.E.S.I. ; M.I.S.T.E. ; C.E. (India)
Recipient of :
‘‘Best Teacher (Academic) Award’’
‘‘Distinguished Author Award’’
‘‘Jawahar Lal Nehru Memorial Gold Medal’’
for an outstanding research paper
(Institution of Engineers–India)
Principal (Formerly):
l Thapar Polytechnic College
l Punjab College of Information Technology
PATIALA
Limits of Liability/Disclaimer of Warranty: The publisher and the author make no representation or warranties with respect to the
accuracy or completeness of the contents of this work and specifically disclaim all warranties. The advice, strategies, and activities
contained herein may not be suitable for every situation. In performing activities adult supervision must be sought. Likewise, common
sense and care are essential to the conduct of any and all activities, whether described in this book or otherwise. Neither the publisher
nor the author shall be liable or assumes any responsibility for any injuries or damages arising herefrom. The fact that an organization
or Website if referred to in this work as a citation and/or a potential source of further information does not mean that the author or
the publisher endorses the information the organization or Website may provide or recommendations it may make. Further, readers
must be aware that the Internet Websites listed in this work may have changed or disappeared between when this work was written
and when it is read.
All trademarks, logos or any other mark such as Vibgyor, USP, Amanda, Golden Bells, Firewall Media, Mercury, Trinity, Laxmi appear-
ing in this work are trademarks and intellectual property owned by or licensed to Laxmi Publications, its subsidiaries or affiliates.
Notwithstanding this disclaimer, all other names and marks mentioned in this work are the trade names, trademarks or service
marks of their respective owners.
Chapter Pages
Chapter Pages
Chapter Pages
3.14.6. Boiler terms ... 99
3.14.7. Fire tube boilers ... 99
3.14.8. Water tube boilers ... 103
3.14.9. High pressure boilers ... 105
3.15. Accessories ... 111
3.15.1. Feed pumps ... 111
3.15.2. Injector ... 111
3.15.3. Economiser ... 112
3.15.4. Air preheater ... 113
3.15.5. Superheater ... 114
3.15.6. Steam separator ... 115
3.16. Feed Water Heaters and Evaporators ... 115
3.16.1. Feed water heaters ... 115
3.16.2. Miscellaneous heaters ... 117
3.16.3. Evaporators ... 117
3.16.4. Typical utility cycle layout ... 117
3.17. Performance of Boilers ... 118
3.17.1. Evaporative capacity ... 118
3.17.2. Equivalent evaporation ... 118
3.17.3. Factor of evaporation ... 119
3.17.4. Boiler efficiency ... 119
3.17.5. Heat losses in a boiler plant ... 119
3.18. Steam Nozzles ... 123
3.18.1. Introduction ... 123
3.18.2. Steam flow through nozzles ... 124
3.18.3. Discharge through the nozzle and conditions for its
maximum value ... 124
3.18.4. Nozzle efficiency ... 126
3.18.5. Supersaturated or metastable expansion of steam in a nozzle ... 127
3.19. Steam Turbines ... 130
3.19.1. Introduction ... 130
3.19.2. Classification of steam turbines ... 131
3.19.3. Advantages of steam turbine over the steam engines ... 132
3.19.4. Description of common types of turbines ... 132
3.19.5. Methods of reducing wheel or rotor speed ... 133
3.19.6. Difference between impulse and reaction turbines ... 135
3.19.7. Impulse turbines ... 135
3.19.8. Reaction turbines ... 140
3.19.9. Turbine efficiencies ... 142
3.19.10. Types of power in steam turbine practice ... 143
3.19.11. Energy losses in steam turbines ... 143
3.19.12. Steam turbine governing and control ... 144
3.19.13. Special forms of turbines ... 146
3.20. Steam Condensers ... 157
3.20.1. Introduction ... 157
3.20.2. Vacuum ... 157
3.20.3. Organs of a steam condensing plant ... 157
3.20.4. Classification of condensers ... 157
3.20.5. Jet condensers ... 157
3.20.6. Surface condensers ... 159
3.20.7. Reasons for inefficiency in surface condensers ... 160
3.20.8. Comparison between jet and surface condensers ... 161
3.20.9. Selection of condenser ... 161
( viii )
Chapter Pages
Chapter Pages
Chapter Pages
Chapter Pages
Chapter Pages
Chapter Pages
Chapter Pages
Chapters—Brief Contents
1. Introductory. This chapter gives the introduction of the various sources of the energy, Principal types
of the Power Plants and Combustion of Fuels.
2. Power Plants Cycles. This chapter deals with the various cycles used in Power Plants, viz., Rankine
Cycle, Regenerative Cycle, Binary Vapour Cycle, Otto Cycle, Diesel Cycle, Duel Combustion Cycle, Gas
Turbine Cycles.
3. Steam Power Plant. Under this chapter, following aspects of Steam Power Plant have been discussed:
Layout of a Modern Steam Power Plant, Fuel Handling, Combustion Equipment for Steam Boilers, Ash
Handling, Dust Collection, Chimney Draught, Boiler Accessories, Steam Nozzles, Steam Turbines, Cool-
ing Towers, Cooling Ponds etc.
4. Diesel Engine Power Plant. This chapter deals with I.C. Engines used in such a Plant and essential
components of Diesel Power Plants. It also deals with Combustion Phenomenon in I.C. Engines along
with its related topics and layout of a Diesel Engine Power Plant etc.
5. Gas Turbine Power Plant. This chapter deals with general aspects of Gas Turbine used in such a Plant
along with the description of Gas Power Cycle used in such turbines. It also deals with topics such as
Operation of Gas Turbines, Gas Turbines Power Plant Layout etc.
6. Hydro-Electric Power Plant. Under this chapter the following topics are dealth with : Elements of
Hydro-Electric Power Plant, Hydro-Electric Turbines, Plant Layout, Hydro-Electric Plant Controls, Hy-
drology etc.
( xvii )
( xviii )
7. Nuclear Power Plant. This chapter deals with the General Aspects of Nuclear Engineering, Nuclear
Power Systems, Nuclear Reactors and their Description, Nuclear Energy etc.
8. Combined Operation of Different Power Plants. This chapter deals with : Advantages of Combined
Operation of Plants, Load Division between Power Stations, Hydro-Electric Plant in Combination with
Steam Plant, Pump Storage Plant in Combination with Steam or Nuclear Power Plants, Co-ordination
of Hydro-Electric and Gas Turbine Stations, Co-ordination of different types of Power Plants.
9. Economics of Power Generation. This chapter deals with topics such as Principle of Power Plant
Design, Location of Power Plant, Layout of Power Plant Building, Cost Analysis, Selection of Type of
Generation, Selection of Power Plant Equipment, Economics in Plant Selection, Economic Load Sharing
etc.
10. Non-Conventional Power Generation. This chapter deals with the Wind Power Plant, Tidal Power
Plant, Solar Power Plant, Geothermal Power Plant, Direct Energy Conversion Systems.
11. Plant Instrumentation. This chapter deals with the various instruments used in a Power Plant such as
Pressure Gauges, Thermometers, Liquid Gauges, Flow Meters, p-H Measuring Instruments, Speed Measuring
Instruments etc.
12. Major Electrical Equipment used in Power Plant. In this chapter following electrical equipment
have been discussed : Generating Equipment, Transformers, Switch Gear, Protection of Electrical Systems.
13. Pollution and its Control. It deals with : Pollution from Thermal Plants, pollution from Nuclear Power
Plants, and pollution from Hydro-electric Power Plants.
Objective Type Questions Bank
The bank assimilates 600 Objective Type Questions.
The book will prove to be of great help to the students preparing for engineering degree, A.M.I.E. (India),
diploma and other competitive examinations.
The author’s grateful thanks are due to Smt. Ramesh Rajput (wife) for extending full co-operation during
the preparation of the manuscript.
The author’s thanks are also due to Mr. Rakesh Syal for drawing neat diagrams for this book.
In the end the author wishes to express his gratitudes to M/s Laxmi Publications for taking extra pains
in printing the book at a rapid pace and very systematically.
Although every care has been taken to make the book free of error both in text as well as in solved
examples, yet the author shall feel obliged if any error present is brought to his notice. Constructive criticism
of the book will be warmly received.
A. INTRODUCTION TO SI UNITS
SI, the international system of units are divided into three classes:
1. Base units 2. Derived units 3. Supplementary units.
From the scientific point of view division of SI units into these classes is to a certain extent arbitrary, because it is
not essential to the physics of the subject. Nevertheless the General Conference, considering the advantages of a single,
practical, world-wide system for international relations, for teaching and for scientific work, decided to base the
international system on a choice of six well-defined units given in Table 1 below:
The second class of SI units contains derived units, i.e., units which can be formed by combining base units
according to the algebraic relations linking the corresponding quantities. Several of these algebraic expressions in terms
of base units can be replaced by special names and symbols can themselves be used to form other derived units.
Derived units may, therefore, be classified under three headings. Some of them are given in Tables 2, 3 and 4.
Quantity SI Units
Name Symbol
area square metre m2
volume cubic metre m3
speed, velocity metre per second m/s
acceleration metre per second squared m/s2
wave number 1 per metre m–1
density, mass density kilogram per cubic metre kg/m3
concentration (of amount of substance) mole per cubic metre mol/m3
activity (radioactive) 1 per second s–1
specific volume cubic metre per kilogram m3/kg
luminance candela per square metre cd/m2
xix
xx POWER PLANT ENGINEERING
Quantity SI Units
Name Symbol Expression in terms Expression in terms
of other units of SI base units
frequency hertz Hz – s–1
force newton N – m.kg.s–2
pressure pascal Pa N/m2 m–1.kg.s–2
energy, work, quantity of heat power joule J N.m m2.kg.s–2
radiant flux quantity of electricity watt W J/s m2.kg.s–3
electric charge coulomb C A.s s.A
electric tension, electric potential volt V W/A m2.kg.s–3.A–1
capacitance farad F C/V m–2.kg–1.s4
electric resistance ohm V/A m2.kg.s–3.A–2
conductance siemens S A/V m–2.kg–1.s3.A2
magnetic flux weber Wb V.S. m2.kg.s–2.A–1
magnetic flux density tesla T Wb/m2 kg.s–2.A–1
inductance henry H Wb/A m2.kg.s–2.A–2
luminous flux lumen lm – cd.sr
illuminance lux lx – m–2.cd.sr
Quantity SI Units
Name Symbol Expression in terms
of SI base units
The SI units assigned to third class called “Supplementary units” may be regarded either as base units or as
derived units. Refer to Table 5 and Table 6.
VED
p-plant (color)\plan14-1 IInd 19-12-14 3nd 12-1-15 4rd 28-2-15 5th 21-4-15 6th 16-05-15 7th 30-06-15
INTRODUCTION TO SI UNITS AND CONVERSION FACTORS xxi
Quantity SI Units
Name Symbol
plane angle radian rad
solid angle steradian sr
Quantity SI Units
Name Symbol
angular velocity radian per second rad/s
angular acceleration radian per second squared rad/s2
radiant intensity watt per steradian W/sr
radiance watt per square metre steradian W-m–2.sr–1
Table 7. SI Prefixes
B. CONVERSION FACTORS
1. Force:
1 newton = kg-m/sec2 = 0.012 kgf
1 kgf = 9.81 N
2. Pressure:
1 bar = 750.06 mm Hg = 0.9869 atm = 105 N/m2 = 103 kg/m-sec2
1 N/m2 = 1 pascal = 10–5 bar = 10–2 kg/m-sec2
1 atm = 760 mm Hg = 1.03 kgf/cm2 = 1.01325 bar
= 1.01325 × 105 N/m2
3. Work, Energy or Heat:
1 joule = 1 newton metre = 1 watt-sec
= 2.7778 × 10–7 kWh = 0.239 cal
= 0.239 × 10–3 kcal
1 cal = 4.184 joule = 1.1622 × 10–6 kWh
1 kcal = 4.184 × 103 joule = 427 kgf-m
= 1.1622 × 10–3 kWh
1 kWh = 8.6042 × 105 cal = 860.42 kcal = 3.6 × 106 joule
FG 1 IJ kcal = 9.81 joules
1 kgf-m =
H 427 K
VED
p-plant (color)\plan14-1 IInd 19-12-14 3nd 12-1-15 4rd 28-2-15 5th 21-4-15 6th 16-05-15 7th 30-06-15
xxii POWER PLANT ENGINEERING
4. Power:
1 watt = 1 joule/sec = 0.860 kcal/h
1 h.p. = 75 m kgf/sec = 0.1757 kcal/sec = 735.3 watt
1 kW = 1000 watts = 860 kcal/h
5. Specific heat:
1 kcal/kg-K = 4.184 kJ/kg-K
6. Thermal conductivity:
1 watt/m-K = 0.8598 kcal/h-m-°C
1 kcal/h-m-°C = 1.16123 watt/m-K = 1.16123 joules/s-m-K.
7. Heat transfer co-efficient:
1 watt/m2-K = 0.86 kcal/m2-h-°C
1 kcal/m2-h-°C = 1.163 watt/m2-K.
VED
p-plant (color)\plan14-1 IInd 19-12-14 3nd 12-1-15 4rd 28-2-15 5th 21-4-15 6th 16-05-15 7th 30-06-15
Compiled by
Smt. RAMESH RAJPUT
Introduction 1
1.1. Energy and power. 1.2. Sources of energy—Fuels—Energy stored in water—Nuclear energy—Wind power—Solar energy—
Tidal power—Geothermal energy—Thermoelectric power. 1.3. Principal types of power plants. 1.4. Combustion of fuels—
Combustion chemistry—How to convert volumetric analysis to weight analysis ?—How to convert weight analysis to volumetric
analysis ?—Weight of air required for complete combustion of fuel—Excess air—Weight of carbon in flue gases—Weight of flue gas
per kg of fuel burnt.—Worked Examples—Highlights—Theoretical Questions—Unsolved Examples.
1.1. ENERGY AND POWER and, to a certain extent, of radiation energy is not ordinarily
thought of as power. Power is primarily associated with
Energy. The historical as well as present-day civilization mechanical work and electrical energy. Therefore, power
of mankind are closely interwoven with energy, and there can be defined as the rate of flow of energy and can state
is little reason to doubt but that in the future our existence that a power plant is a unit built for production and delivery
will be ever more dependent upon this thing called energy. of a flow of mechanical and electrical energy. In common
Energy probably was the original stuff or creation. Energy usage, a machine or assemblage of equipment that produces
appears in many forms, but has one thing in common— and delivers a flow of mechanical or electrical energy is a
energy is possessed of the ability to produce a dynamic, vital power plant. Hence, an internal combustion engine is a
effect. Energy is associated with physical substance, but is power plant, a water wheel is a power plant, etc. However,
not a substance itself. It shows itself by excited, animated what we generally mean by the term is that assemblage of
state assumed by material which receives energy. The equipment, permanently located on some chosen site which
examples which can be quoted in respect of energy are receives raw energy in the form of a substance capable of
almost endless in number. In this era energy is being being operated on in such a way as to produce electrical
produced in enormous quantities. As more and more of it energy for delivery from the power plant.
is produced per person, the comforts, conveniences, and With the advancement in technology the power
pleasures of life are even enhanced. consumption is rising steadily. This necessitates that in
Energy exists in various forms e.g., mechanical, addition to the existing sources of power such as coal, water,
thermal, electrical etc. One form of energy can be converted petroleum etc. other sources of energy should be searched
into other by the use of suitable arrangements. Out of all out and new and more efficient ways of producing energy
these forms of energy, electrical energy is preferred due to should be devised. Nuclear energy has enlarged the world’s
the following advantages : 1. Can be easily transported from power resources. The energy released by 1 kg of uranium
one place to another. 2. Losses in transport are minimum. is equivalent to energy obtained by 4500 tonnes of high grade
3. Can be easily subdivided. 4. Economical in use. 5. Easily coal.
converted into other forms of energy. 6. Easily controlled
and regulated to suit requirements. 1.2. SOURCES OF ENERGY
Power. Any physical unit of energy when divided
The various sources of energy are :
by a unit of time automatically becomes a unit of power.
However, it is in connection with the mechanical and R|Solids Coal, coke anthracite etc.
electrical forms of energy that the term “power” is generally
1. Fuels S
|Liquids Petroleum and its derivates
used. The rate of production or consumption of heat energy ||Gases Natural gas, blast furnace
T gas etc.
1
2 POWER PLANT ENGINEERING
2. Energy stored in water Peat. It is the first stage in the formation of coal
3. Nuclear energy from wood. It contains huge amount of moisture and
therefore it is dried for about 1 to 2 months before it is put
4. Wind power
to use. It is used as a domestic fuel in Europe and for power
5. Solar energy generation in Russia. In India it does not come in the
6. Tidal power categories of good fuels.
7. Geothermal energy Lignites and brown coals. These are intermediate
8. Thermoelectric power. stages between peat and coal. They have a woody or often
a clay like appearance associated with high moisture, high
1.2.1. Fuels ash and low heat contents. Lignites are usually amorphous
Fuels may be chemical or nuclear. Here we shall consider in character and impose transport difficulties as they break
chemical fuels only. easily. They burn with a smoky flame. Some of this type
A chemical fuel is a substance which releases heat are suitable for local use only.
energy on combustion. The principal combustible elements Bituminous coal. It burns with long yellow and
of each fuel are carbon and hydrogen. Though sulphur is a smoky flames and has high percentages of volatile matter.
combustible element too but its presence in the fuel is The average calorific value of bituminous coal is about
considered to be undesirable. 31350 kJ/kg. It may be of two types, namely caking or non-
caking.
Classification of fuels : Semi-bituminous coal. It is softer than the
Fuels can be classified according to whether anthracite. It burns with a very small amount of smoke. It
1. They occur in nature called primary fuels or are contains 15 to 20 per cent volatile matter and has a
prepared called secondary fuels. tendency to break into small sizes during storage or
2. They are in solid, liquid or gaseous state. The transportation.
detailed classification of fuels can be given in a summary Semi-anthracite. It has less fixed carbon and less
form as below : lustre as compared to true anthracite and gives out longer
and more luminous flames when burnt.
Type of fuel Natural Prepared Anthracite. It is very hard coal and has a shining
(Primary) (Secondary) black lustre. It ignites slowly unless the furnace tempera-
ture is high. It is non-caking and has high percentage of
Solid Wood Coke fixed carbon. It burns either with very short blue flames or
Peat Charcoal without flames. The calorific value of this fuel is high to
Lignite coal Briquettes the tune of 35500 kJ/kg and as such is very suitable for
Liquid Petroleum Gasoline steam generation.
Kerosene Wood charcoal. It is obtained by destructive
Fuel oil distillation of wood. During the process the volatile matter
Alcohol and water are expelled. The physical properties of the
Benzol residue (charcoal) however depends upon the rate of heating
Shale oil and temperature.
Coke. It consists of carbon, mineral matter with
Gaseous Natural gas Petroleum gas
about 2% sulphur and small quantities of hydrogen,
Producer gas
nitrogen and phosphorus. It is solid residue left after the
Coal gas
destructive distillation of certain kinds of coals. It is
Coke-oven gas
Blast furnace gas
smokeless and clear fuel and can be produced by several
Carburetted gas processes. It is mainly used in blast furnace to produce
heat and at the same time to reduce the iron ore.
Sewer gas
Briquettes. These are prepared from fine coal or
coke by compressing the material under high pressure.
1.2.1.1. Solid fuels
Analysis of coal. The following two types of
Coal. Its main constituents are carbon, hydrogen, oxygen, analysis is done on the coal :
nitrogen, sulphur, moisture and ash. Coal passes through 1. Proximate analysis
different stages during its formation from vegetation. These
2. Ultimate analysis.
stages are enumerated and discussed below :
1. Proximate analysis. In this analysis, individual
Plant debris-Peat-Lignite-Brown coal-Sub-bitumi-
elements are not determined ; only the percentage of
nous coal-Bituminous coal-Semi-bituminous coal-Semi-
moisture, volatile matters, fixed carbon and ash are
anthracite coal-Anthracite coal-graphite.
determined.
INTRODUCTION 3
Example. Moisture = 4.5%, volatile matter = 5.5%, —ash softening temperature of 2400–2590°F, and
fixed carbon = 20.5%. —a sulphur content of 1.4 to 1.6%.
This type of analysis is easily done and is for com- A rank and grade of a coal gives a complete report
mercial purposes only. of the material. Thus the following rank and grade of the
2. Ultimate analysis. In the ultimate analysis, the coal described above :
percentage of various elements are determined. (62–500), 5–10 cm, 500-A8-F24-S1.6.
Example. Carbon = 90%, hydrogen = 2%, oxygen =
4%, nitrogen = 1%, sulphur = 15% and ash = 1.5%. 1.2.1.2. Liquid fuels
This type of analysis is useful for combustion The chief source of liquid fuels is petroleum which is
calculations. obtained from wells under the earth’s crust. These fuels
have proved more advantageous in comparison to solid fuels
Properties of Coal. Important properties of coal in the following respects.
are given below :
Advantages :
1. Energy content or heating value
1. Require less space for storage.
2. Sulphur content
3. Burning characteristics 2. Higher calorific value.
4. Grindability 3. Easy control of consumption.
5. Weatherability 4. Staff economy.
6. Ash softening temperature. 5. Absence of danger from spontaneous combustion.
A good coal should have : 6. Easy handling and transportation.
(i) low ash content and high calorific value 7. Cleanliness.
(ii) small percentage of sulphur (less than 1%) 8. No ash problem.
(iii) good burning characteristics (i.e., should burn 9. Non-deterioration of the oil in storage.
freely without agitation) so that combustion will be com- Petroleum. There are different opinions regarding
plete the origin of petroleum. However, now it is accepted that
(iv) high grindability index (in case of ball mill grind- petroleum has originated probably from organic matter like
ing) fish and plant life etc., by bacterial action or by their
(v) high weatherability. distillation under pressure and heat. It consists of a mixture
of gases, liquids and solid hydrocarbons with small amounts
Ranking of Coal. ASME and ASTM have accepted
of nitrogen and sulphur compounds. In India the main
a specification based on the fixed carbon and heating value
sources of petroleum are Assam and Gujarat.
of the mineral matter free analysis.
Heavy fuel oil or crude oil is imported and then
—Higher ranking is done on the basis of fixed refined at different refineries. The refining of crude oil
carbon percentage (dry basis). supplies the most important product called petrol. Petrol
—Lower ranking is done on the heating value on can also be made by polymerization of refinery gases.
the moist basis. Other liquid fuels are kerosene, fuels oils, colloidal
Example. 62% C and a calorific value of 5000 kcal/kg fuels and alcohol.
is ranked as (62–500) rank. The following table gives composition of some com-
Rank is an inherent property of the fuel depending mon liquid fuels used in terms of the elements in weight
upon its relative progression in the classification process. percentage.
Grading of Coal. Grading is done on the following Fuel Carbon Hydrogen Sulphur Ash
basis :
Petrol 85.5 14.4 0.1 –
(i) Size (ii) Heating value
Benzene 91.7 8.0 0.3 –
(iii) Ash content Kerosene 86.3 13.6 0.1 –
(iv) Ash softening temperature Diesel oil 86.3 12.8 0.9 –
(v) Sulphur content. Light fuel oil 86.2 12.4 1.4 –
Example. A grade written as 5–10 cm, 500-A8-F24- Heavy fuel oil 88.3 9.5 1.2 1.0
S1.6 indicate the coal as having :
Important Properties of Liquid Fuels
—a size of 5–10 cm,
(1) Specific gravity (2) Flash point
—heating value of 5000 kcal/kg,
(3) Fire point (4) Volatility
—8 to 10% ash,
4 POWER PLANT ENGINEERING
(5) Pour point (6) Viscosity is suitable for large installations. It is also used in steel
(7) Carbon residue (8) Octane number industry for firing open hearth furnaces.
(9) Cetane number (10) Corrosive property Water or Illuminating gas. It is produced by blow-
(11) Ash content (12) Gum content ing steam into white hot coke or coal. The decomposition
of steam takes place liberating free hydrogen and oxygen
(13) Heating value (14) Sulphur content.
in the steam combines with carbon to form carbon monox-
The requisite properties vary from device to device ide according to the reaction :
which uses the fuel to generate power. For example, higher
C + H2O CO + H2
the octane number, higher can be the compression ratio and
the thermal efficiency will be higher. Similarly, the cetane The gas composition varies as the hydrogen content
number of a diesel oil should be as high as possible. if the coal is used.
In general the liquid fuels should have : Sewer gas. It is obtained from sewage disposal vats
in which fermentation and decay occur. It consists of mainly
(i) low ash content (ii) high heating value
marsh gas (CH4) and is collected at large disposal plants.
(iii) low gum content (iv) less corrosive tendency It works as a fuel for gas engines which is turn drive the
(v) low sulphur content (vi) low pour point. plant pumps and agitators.
Viscosity and other properties vary from purpose to Gageous fuels are becoming popular because of
purpose to which the fuel is employed. following advantages they possess :
1.2.1.3. Gaseous fuels Advantages :
1. Better control of combustion.
Natural gas. The main constituents of natural gas are
methane (CH4) and ethane (C2H6). It has calorific value 2. Much less excess air is needed for complete
nearly 21000 kJ/m3. Natural gas is used alternately or combustion.
simultaneously with oil for internal combustion engines. 3. Economy in fuel and more efficiency of furnace
Coal gas. Mainly consists of hydrogen, carbon mon- operation.
oxide and hydro-carbons. It is prepared by carbonization 4. Easy maintenance of oxidizing or reducing
of coal. It finds its use in boilers and sometimes used for atmosphere.
commercial purposes. 5. Cleanliness.
Coke-oven gas. It is obtained during the production 6. No problem of storage if the supply is available
of coke by heating the bituminous coal. The volatile content from public supply line.
of coal is driven off by heating and major portion of this
7. The distribution of gaseous fuels even over a
gas is utilised in heating the ovens. This gas must be
wide area is easy through the instrumentality of pipe lines
thoroughly filtered before using in gas engines.
and as such handling of the fuel is altogether eliminated.
Blast furnace gas. It is obtained from smelting
Gaseous fuels give economy of heat and produce higher
operation in which air is forced through layers of coke and
temperatures as they can be preheated in regenerative
iron ore, the example being that of pig iron manufacture
furnaces and thus heat from hot flue gases can be recovered.
where this gas is produced as by product and contains about
20% carbon monoxide (CO). After filtering it may be Important Properties of Gaseous Fuels
blended with richer gas or used in gas engines directly. 1. Heating value or calorific value
The heating value of this gas is very low. 2. Viscosity
Producer gas. It results from the partial oxidation
3. Specific gravity
of coal, coke or peat when they are burnt with an
insufficient quantity of air. It is produced in specially 4. Density
designed retorts. It has low heating value and in general 5. Diffusibility.
Typical composition of some gaseous fuels is given below :
Fuel H2 CO CH4 C2H4 C2H6 C4H8 O2 CO2 N2
Natural gas – 1 93 – 3 – – – 3
Coal gas 53.6 9.0 25 – – 3 0.4 3 6
Blast furnace gas 2 27 – – – – – 11 –
1.2.1.4. Calorific or Heating values of fuels Fuels which contain hydrogen have two calorific
values, the higher and the lower. The ‘lower calorific value’
The calorific value of the fuel is defined as the energy is the heat liberated per kg of fuel after deducting the heat
liberated by the complete oxidation of a unit mass or volume necessary to vaporise the steam, formed from hydrogen.
of a fuel. It is expressed in kJ/kg for solid and liquid fuels The ‘higher or gross calorific value’ of the fuel is one
and kJ/m3 for gases.
INTRODUCTION 5
indicated by a constant-volume calorimeter in which the in comparison with steam power, but from the stand point
steam is condensed and the heat of vapour is recovered. of the conservation of a fixed natural resource, namely, its
The lower or net calorific value is obtained by mineral fuels, it is obvious that every effort should be made
subtracting latent heat of water vapour from gross calorific to harness the water power of the country, since if
value. In other words, the relation between lower calorific unharnessed it goes to waste, whereas fuel, if unmined,
value (L.C.V.) and higher calorific value (H.C.V.) can be remains intact and undiminished in value in the ground.
expressed in the following way : Water power is quite cheap where water is available
L.C.V. = (H.C.V. — 2465 mw) ...(1.1) in abundance. Although capital cost of hydroelectric power
where mw is the mass of water vapour produced by plants is higher as compared to other types of power plants
combustion of 1 kg of fuel and 2465 kJ/kg is the latent yet their operating costs are quite low.
heat corresponding to standard temperature (saturation) 1.2.3. Nuclear Energy
of 15C.
One of the outstanding facts about nuclear power is the
LMIn MKS units : OP large amount of energy that can be released from a small
MMwhere m is the mass of water vapour PP
L.C. V. (H.C. V. 588.76 m )
w
w mass of active material. Complete fission of one kg of
uranium contains the energy equivalent of 4500 tonnes of
MMproduced by combustion of 1kg of fuel PP coal or 2000 tonnes of oil. The nuclear power is not only
MMand
kcal as read from steam tables for 1 kg P
588.76 is the latent heat value in
PQ
available in abundance but it is cheaper than the power
generated by conventional sources.
Nof water vapour. The following factors go in favour of nuclear energy :
Dulong’s Formula (Solid/liquid fuels). Dulong (i) Practically independent of geographical factors.
suggested a formula for the calculation of the calorific value (ii) No combustion products.
of the solid or liquid fuels from their chemical composition
(iii) Clean source of power which does not contribute
which is as given below :
to air pollution.
Gross calorific value
(iv) Fuel transportation networks and large storage
1 LM O FG IJ OP facilities not required.
or H.C.V. =
100
33800 144000 H
N 8 H K
9270 S kJ/kg
Q The economic advantage of nuclear power can be
...(1.2) realised only if one can ensure a guaranteed base load of
LMIn MKS units: O about 75%. The number of electro-chemical processes
L F O I OP
(fertiliser plants), desalination of water and use of elec-
MMH.C. V. = 1 M8080 C 34500 GH H 8 JK PPP tricity for pumping water from tube wells assure a con-
MN 100 M
MN P
2240 S kcal / kg PQ PQ
stant base load. Therefore, such type of power requirements
must be developed before the adoption of nuclear power in
where C, H, O and S are carbon, hydrogen, oxygen and the country.
sulphur in percentages respectively in 100 kg of fuel. In
1.2.4. Wind Power
the above formula, the oxygen is assumed to be in
combination with hydrogen and only extra surplus The man has been served by the power from winds for many
hydrogen supplies the necessary heat. centuries but the total amount of energy generated in this
manner is small. The expense of installation and variability
1.2.2. Energy Stored in Water of operation have tended to limit the use of the windmill to
The energy contained in flowing streams of water is a form intermittent services where its variable output has no
of mechanical energy. It may exist as the kinetic energy of serious disadvantage. The principal services of this nature
a moving stream or as potential energy of water at some are the pumping of water into storage tanks and the
elevation with respect to a lower datum level, an example charging of storage batteries.
of which would be the water held behind a dam. Hydraulic Windmill power equipment may be classified as
plants are slowly increasing in number, although the follows :
number of new plants of this type built is quite small 1. The multi-bladed turbine wheel. This is the
compared with those which exploit heat energy. As a usual foremost type in use and its efficiency is about 10 per cent
thing, the most desirable hydroelectric sites are the first of the kinetic energy of the wind passing through it.
to be utilized, consequently, as more hydroelectric plants 2. The high-speed propeller type.
are built, the owners must pay increasingly higher 3. The rotor.
development costs.
The propeller and rotor types are suitable for the
From the stand point of capitalistic economics, it is generation of electrical energy, as both of them possess the
often hard to justify the development of hydroelectric power ability to start in very low winds. The Propeller type is more
6 POWER PLANT ENGINEERING
likely to be used in small units such as the driving of small For developing solar energy two ways have been
battery charging generators, whereas the rotor, which is explored viz., the glass lens and the reflector. These devices
rarely seen, is more practical for large installations, even concentrate the solar rays to a focal point which is
of several hundred kilowatts’ capacity. characterised by a high degree of heat which can be utilised
In India, the wind velocity along coastline has a to boil water and generate steam. The reflector is the better
range 10–16 kmph and a survey of wind power has revealed of the two methods due to the convenience with which it
that wind power is capable of exploitation for pumping can be manufactured in different shapes and sizes. If an
water from deep wells or for generating small amounts of arrangement is provided to turn the reflector with the sun,
electric energy. so that the rays can constantly concentrate at the focal
Modern windmills are capable of working on veloci- point, a continuous supply of heat is made available during
ties as low as 3–7 kmph while maximum efficiency is at- the hours of the day. However, a great deal of practical
tained at 10–12 kmph. research is still necessary before the solar energy can be
commercially exploited at a cheaper rate.
A normal working life of 20 to 25 years is estimated
for windmills. Conditions for utilisation of solar energy, in India,
are favourable since for nearly six months of the year
The great advantage of this source of energy is that
sunshine is uninterrupted during the day, while in the other
no operator is needed and no maintenance and repairs are
six months cloudy weather and rain provide conditions
necessary for long intervals.
suitable for water power. Thus, a coordination of solar
Characteristics of wind power/energy. Some energy with water power can provide a workable plan for
characteristics of wind energy are given below : most places in India.
1. No fuel provision and transport are required in 1.2.6. Tidal Power
wind energy systems.
2. It is a renewable source of energy. The rise and fall of tides offers a means for storing water
at the rise and discharging the same at fall. Of course the
3. Wind power systems are non-polluting.
head of water available under such cases is very low but
4. Wind power systems, up to a few kW, are less with increased catchment area considerable amounts of
costly, but on a large scale, costs can be competitive with power can be generated at a negligible cost.
conventional electricity. Lower costs can be achieved by
mass production. Dam
Problems associated with “wind energy”:
1. Wind energy systems are noisy in operation. High tide
2. Large areas are needed to install wind farms for Turbine
electrical power generators. Tidal basin generator
3. Wind energy available is dilute and fluctuating Sea
in nature. Because of dilute form, conversion machines have
to be necessarily large.
4. Wind energy needs storage means because of its
irregularity. (a)
scale hydroelectric plant. To harness the tides, a dam would likelihood of an unsuccessful conclusion are not very con-
be built across the mouth of the bay in which large gates ductive to exploitation of this source of energy.
and low head hydraulic turbines would be installed. At the There are two ways of electric power production from
time of high tide the gates are opened and after storing geothermal energy :
water in the tidal basin the gates are closed. After the tide (i) Heat energy is transferred to a working fluid
has received, there is a working hydraulic head between which operates the power cycle. This may be particularly
the basin water and open sea/ocean and the water is al- useful at places of fresh volcanic activity where the molten
lowed to flow back to the sea through water turbines in- interior mass of earth vents to the surface through fissures
stalled in the dam. With this type of arrangement, the gen- and substantially high temperatures, such as between 450
eration of electric power is not continuous. However by to 550°C can be found. By embedding coil of pipes and
using reversible water turbine the turbine can be run con- sending water through them steam can be raised.
tinuously as shown in Fig. 1.1.
(ii) The hot geothermal water and/or steam is used
1.2.7. Geothermal Energy to operate the turbines directly. From the well-head the
steam is transmitted by pipe lines up to 1 m in diameter
In many places on the earth natural steam escapes from
over distances up to about 3 km to the power station. Water
surface vents. Such natural steam wells suggest the possi-
separators are usually employed to separate moisture and
bility of tapping terrestrial heat (or geothermal energy) in
solid particles from steam.
this form and using it for the development of power. Un-
fortunately, the locations where the steam-producing sub- Presently, only steam coming out of the ground is
strata seem to be fairly close to the surface are far removed used to generate electricity, the hot water is discarded,
from centres of civilization where the power could be use- because it contains as much as 30% dissolved salts and
fully employed. Nevertheless, there are probably many minerals, and these cause serious rust damage to the
places where, although no natural steam vent or hot springs turbine. The water, however, contains more than 31 rd of
are showing, deep drillings might tap a source of under- the available thermal energy.
ground steam. The cost of such explorations and the great
Jet condenser
Cooling
water in Water separator
Steam
turbine
Generator
Condensate Dry/Wet
(for local use) steam
Geothermal zone
Steam plants using Coal, Oil or Nuclear weight of some important elements, compounds and gases.
Fission. The steam plants in which coal or oil is used Table 1.1 given below satisfies the requirement.
comprise the steam generating equipment and the prime
Table 1.1
movers. In the boilers/steam generators steam is produced
and then utilised to drive the turbines/engines which are
Molecule Atom
coupled to generators to get electricity. The furnace may
employ grate burning of solid fuel, pulverised fuel in burners Symbol Molecule Symbol Molecular
or furnace oil in oil burners. Besides, the plant may contain weight weight
several heat saving devices such as water heaters,
economisers, air pre-heater etc. which effect an Hydrogen H2 2 H 1
improvement in the overall efficiency of all boiler plants. Oxygen O2 32 O 16
The equipment for firing of fuel into the furnaces and also Nitrogen N2 28 N 14
that for handling of fuel and ash are other important Carbon C 12 C 12
aspects of plant study besides such auxiliary equipment Sulphur S 32 S 32
as needed for condensing exhaust steam, water treatment, Water H2 O 18 – –
water cooling, dust removal, draft control etc. Carbon monoxide CO 28 – –
In nuclear stations heat is produced in a reactor Carbon dioxide CO2 44 – –
which replaces the conventional boiler. Sulphur dioxide SO2 64 – –
Internal Combustion Engine Plants. In these Marsh gas (Methane) CH4 16 – –
plants spark ignition (S.I.) or compression ignition (C.I.) Ethylene C2H4 28 – –
engines are used as prime movers to drive electric Ethane C2H6 30 – –
generators. The C.I. engines using diesel fuel are most
commonly used whereas the use of S.I. engines are restricted 1. Carbon (complete combustion)
to drive small portable electric generators. The complete combustion of carbon may be
The diesel engine power plant may, besides the expressed by
engine proper, include fuel handling, oil cooling, water C + O2 = CO2 ...(1.3)
cooling, starting and supercharging equipment.
8 11
Gas Turbine Plant. A gas turbine plant, working or 1 kg (carbon) + kg (oxygen) = kg (carbon dioxide)
3 3
on a modified gas cycle, would contain besides the gas ...(1.4)
turbine, the starting device, auxiliary lubrication, fuel Equation (1.3) indicates that one molecule of carbon
control system, oil cooler, combustor, reheater, regenerator combines with one molecule of oxygen to give one molecule
etc. A combination gas turbine plant employs an auxiliary of carbon dioxide.
steam plant obtaining its heat from gas turbine exhaust.
Equation (1.4) indicates that 1 kg of carbon needs
Such a combination plant has advantage of both gas and
8/3 kg of oxygen for its complete combustion and produces
steam plants and some commercial plants are working on
11/3 kg of carbon dioxide.
this system.
2. Carbon (incomplete combustion)
Hydroelectric Plants. This type of plant makes
use of energy of water stored at an elevation and allowed Carbon combines with oxygen to form carbon
to drop to a lower level. The electric generator is driven by monoxide (and not carbon dioxide as in the first case)
a water turbine through which the water from the pond is according to the equation :
made to work. 2C + O2 = 2CO
A hydroelectric plant comprises the turbines, 2 mol + 1 mol = 2 mol
governing gear, coolant circulators etc. or 1 mol + 1/2 mol = 1 mol ...(1.5)
The operation of such a plant is usually much 24 + 32 = 56
simpler than that of a steam, diesel or gas powered plant.
or 1 kg (carbon) + 4/3 kg (oxygen)
1.4. COMBUSTION OF FUELS = 7/3 kg (carbon monoxide) ...(1.6)
Equation (1.5) indicates that 1 molecule of carbon
1.4.1. Combustion Chemistry combines with 21 molecule of oxygen to produce 1 molecule
Under this heading we shall consider various important of carbon monoxide.
reactions concerning different elements which go to form Equation (1.6) represents that 1 kg of carbon
the fuels and gases. Primarily there will be necessity to requires 4/3 kg of oxygen to produce 7/3 kg of carbon
have some knowledge about the symbols and molecular monoxide.
INTRODUCTION 9
because whole of air supplied for combustion purposes does Therefore, weight of carbon per kg of fuel
not come in contact with the fuel completely and as such a FG 3 CO
3 IJ
portion of fuel may be left unburnt. But if a large quantity
of excess air is used it exercises a cooling effect on
= H 11
7
CO 2
K
where CO2 and CO are the quantities of carbon dioxide
combustion process which however can be avoided by
and carbon monoxide present in 1 kg of flue or exhaust
preheating the air. The weight of excess air supplied can be
gas.
determined from the weight of oxygen which is left unused.
The amount of excess air supplied varies with the 1.4.7. Weight of Flue Gas per kg of Fuel Burnt
type of fuel and the firing conditions. It may approach a Due to supply of air, the weight of flue gas or exhaust gas
value of 100% but modern practice is to use 25% to 50% is always more than that of fuel burnt. The actual weight
excess air. of dry flue gases can be obtained by comparing the weight
1.4.6. Weight of Carbon in Flue Gases of carbon present in the flue gases with the weight of carbon
in the fuel, since there is no loss of carbon during the
The weight of carbon contained in one kg of flue or exhaust combustion process. As the analysis of the exhaust gases
gas can be calculated from the amounts of CO2 and CO is volumetric, so this must first be reduced to weight
contained in it. analysis.
In eqn. (1.4) it was shown that 1 kg of carbon Also, total weight of carbon in one kg of flue gas is
produces 11/3 kg of CO2 when completely burnt. Hence 1 kg
FG 3 CO
3 IJ
of CO2 will contain 3/11 kg of carbon.
In eqn. (1.6) it can be seen that 1 kg of carbon
= H 11
7
CO 2
K
produces 7/3 kg of CO, hence 1 kg CO contains 3/7 kg of The weight of flue gas/kg of fuel burnt
carbon. Weight of carbon in one kg of fuel
= .
Weight of carbon in one kg of flue gas
WORKED EXAMPLES
Example 1.1. The percentage composition of sample of Excess air supplied
liquid fuel by weight is, C = 84.8 per cent, and H2 = 15.2 per 15.11 15
cent. Calculate (i) the weight of air needed for the combustion = = 2.266 kg
100
of 1 kg of fuel ; (ii) the volumetric composition of the products Wt. of oxygen in excess air
of combustion if 15 per cent excess air is supplied. 2.266 23
Solution. = = 0.521 kg
100
Element, wt (kg) O2 used (kg) Dry products (kg) Total air supplied for combustion
8 0.848 11 = Minimum air + Excess air
C = 0.848 0.848 × = 2.261
3 3 = 15.11 + 2.266 = 17.376 kg
H2 = 0.152 0.152 × 8 = 1.216 = 3.109 (CO2) Wt. of nitrogen (N2) in flue gases
Total O2 = 3.477 17.376 77
(i) Minimum weight of air needed for combustion: = = 13.38 kg.
100
3.477 100 (ii) To get volumetric composition of the products of
= = 15.11 kg. (Ans.) combustion let us use tabular method:
23
z = 0.5650
INTRODUCTION 11
Amount of carbon present per kg of gases hydrogen is burnt and that the carbon burns to carbon
= Amount of carbon in 0.1525 kg of CO2 monoxide and carbon dioxide so that there is no free carbon
+ Amount of carbon present in 0.0019 kg of CO left, calculate the percentage analysis of dry exhaust gases
by volume.
3 3
= × 0.1525 + × 0.0019 = 0.0416 + 0.0008 Solution.
11 7
= 0.0424 kg. Element, wt. (kg) O2 needed (kg)
Also carbon in the fuel = 0.78 kg. C = 0.86 0.86 × 8/3 = 2.29
Weight of dry flue gas per kg of fuel H2 = 0.14 0.14 × 8 = 1.12
Weight of carbon in 1 kg of fuel Total O2 needed = 3.41
= Minimum quantity of air for complete combustion
Weight of carbon in 1 kg of flue gas
0.78 3.41 100
= = 18.4 kg. (Ans.) = = 14.83 kg/kg of fuel.
0.0424 23
Amount of less air supplied
(ii) Weight of excess air per kg of fuel :
Weight of excess oxygen per kg of flue gas 14.83 10
= = 1.483 kg/kg of fuel.
4 100
= 0.0832 – × 0.0019 Amount of air saved by burning carbon to carbon
7
LM O monoxide instead of carbon dioxide
2CO + O 2CO P 100
MM 56 32 88 PP
2 2 = Oxygen saved ×
23
MM1 kg 4 kg 11 kgPP LM 8 (CO ) 4 (CO)OP 100
N 7 7 Q
=
N3 2
3 Q 23
= 0.0832 – 0.0011 = 5.8 kg/kg of carbon.
(allowing for unburnt carbon monoxide) 1.483
Hence = 0.256 kg of carbon burns to carbon
= 0.0821 kg 5.8
Weight of excess O2 per kg of fuel monoxide and as such 0.86 – 0.256 = 0.604 kg of carbon
= 18.4 × 0.0821 = 1.51 kg burns to carbon dioxide.
Weight of excess air per kg of fuel Carbon dioxide (CO2) formed
= 0.604 × 11/3 = 2.215 kg
1.51 100
= = 6.56 kg. (Ans.) Carbon monoxide (CO) formed
23
Example 1.4. A petrol sample was found to have 86 per = 0.256 × 7/3 = 0.597 kg
cent carbon and 14 per cent hydrogen by weight. When used Nitrogen in the air supplied
in an engine the air supply is 90 per cent of that theoretically = 14.83 × 77/100 × 0.9 = 10.3 kg.
required for complete combustion. Assuming that all the
Volumetric analysis of dry exhaust gases
2.215 0.050
CO2 2.215 44 = 0.050 × 100 = 11.39%
44 0.439
0.597 0.021
CO 0.597 28 = 0.201 × 100 = 4.78%
28 0.441
10.3 0.368
N2 10.3 28 = 0.368 × 1 = 83.82%
28 0.441
z = 0.439 Ans.
INTRODUCTION 13
Example 1.5. A boiler in a power station was fired with Weight of N2 in the air required for combustion
coal having an ultimate composition of C = 84%, H2 = 4.5%, = 11.13 × 0.77 = 8.57 kg.
O2 = 4.0% and the rest non-combustibles and calorific value Weight of N2 in excess air
of 33900 kJ/kg. The coal was burnt with 85% excess air
= 11.13 × 0.77 × 0.85 = 7.285 kg
and the mean temperature of the flue gases leaving the boiler
was found to be 315.5°C when the ambient temperature in Total N2 = 8.57 + 7.285 = 15.85 kg
the boiler bouse was 32.22°C. Assuming air to be consisting O2 in excess air = 11.13 × 0.85 × 0.23 = 2.18 kg.
of 23% by weight of O2 and 77% by weight of N2 and specific (ii) Total wt. of flue gases:
heat of flue gases as 1.005 kJ/kg K, determine : = Wt. of CO2 + Wt. of N2 + Wt.
(i) kg air actually supplied per kg coal burnt. of O2 in excess air
(ii) kg flue gases per kg fuel burnt. = 3.08 + 15.85 + 2.18
(iii) The percentage of the energy of the coal that is = 21.11 kg. (Ans.)
carried away by flue gases per kg of coal burnt. Heat taken away by flue gases
Solution. = Weight of flue gases × specific heat
Element, wt. O2 required Wt. of products × rise of temperature
(kg) (kg) (kg) = 21.11 × 1.005 × (315.5 – 32.22)
8 11 = 6010 kJ
C = 0.84 0.84 × = 2.24 0.84 × = 3.08 (CO2)
3 3 (iii) Percentage energy of coal taken away by flue
H2 = 0.045 0.045 × 8 = 0.36 gases per kg:
Total O2 = 2.60 6010
= × 100 = 17.73%. (Ans.)
Weight of O2 already present in the fuel 33900
= 0.04 Example 1.6. The following is the ultimate analysis of a
Weight of O2 needed for combustion sample of petrol by weight :
= 2.60 – 0.04 = 2.56 kg Carbon = 85% ; Hydrogen = 15%.
Calculate the ratio of air to petrol consumption by
Air required for combustion
weight if the volumetric analysis of the dry exhaust gas is :
= 2.56 × 100/23 = 11.13 kg.
CO2 = 11.5% ; CO = 1.2%, O2 = 0.9% ; N2 = 86%.
(i) Actual quantity of air supplied: Also find percentage excess air.
= 1.85 × 11.13 = 20.6 kg. (Ans.)
Solution.
z = 29.76
Weight of carbon per kg of flue gas Total weight of gas = 16.6 + 1.35
= Weight of carbon in 0.17 kg of CO2 = 17.95 kg per kg of fuel.
+ weight of carbon in 0.0113 kg of CO Air supplied = (17.95 – 1)
3 3 = 16.95 kg/kg of fuel
= × 0.17 + × 0.0113 = 0.0512 kg
11 7 Ratio of air to petrol = 16.95 : 1. (Ans.)
Weight of dry flue gas per kg of fuel Stoichiometric air
0.85 LMFG 0.85 8 IJ (0.15 8)OP 100
NH 3K
= = 16.6 kg
0.0512
Vapour of combustion = 9 × 0.15 = 1.35 kg
=
Q 23
= 15.07 kg per kg of fuel
14 POWER PLANT ENGINEERING
z = 0.4026
Example 1.8. Find an expression for the weight of air CO2 = Percentage by volume of
supplied per kg of fuel when carbon content of the fuel and carbon dioxide in the dry flue gas,
the volumetric analysis of the flue gas is known. CO = Percentage by volume of
Show that carbon burnt to CO per kg of fuel is carbon monoxide in the dry flue gas, and
N2 = Percentage by volume of nitrogen in
(CO)(C)
where CO and CO2 represent percentage of the dry flue gas.
CO CO2
carbon monoxide and carbon dioxide in dry flue gas by Consider 100 m3 of the gas.
volume and C represents percentage by weight of carbon The actual weight of CO2
that is actually burnt. = CO2 × a × b × 44 in 100 m3 of gas.
Solution. Let C = Percentage of carbon, by weight, in The actual weight of CO
the fuel burnt, = CO × a × b × 28 in 100 m3 of gas.
INTRODUCTION 15
1 L
M33800 65 144000 FGH 6 188 IJK 9270 1.5OPQ
at a pressure of 8 bar absolute. The dryness fraction of the
steam may be taken 0.95. Coal used has the following
100 N
=
composition per kg :
1 Carbon = 0.70
= [2197000 + 540000 + 13905] Hydrogen = 0.05
100
1 Oxygen = 0.10
= (2750905) = 27509 kJ/kg. Sulphur = 0.02
100
Also the combustion of 1 kg of coal produces Ash = 0.13
0.06 × 9 = 0.54 kg of steam. If the hourly rate of burning is 60 kg and the feed
L.C.V. = (H.C.V. – 2465 mw) water temperature is 25°C, calculate the boiler efficiency.
= (27509 – 2465 × 0.54) Solution. From steam tables, corresponding to 8 bar
= (27509 – 1331) = 26178 kJ/kg. (Ans.) pressure,
hf = 720.9 kJ/kg
Example 1.11. Find the gross thermal efficiency of boiler
hfg = 2046.5 kJ/kg
in which the quantity of steam raised per hour was 2250 kg
and the coal consumption was 225 kg per hour. Quantity of heat supplied per kg of steam
From the analysis by weight the dried fuel was found = (hf + xhfg) – 1 × 4.18 × (25 – 0)
to contain 87% carbon and 4% hydrogen. The feed water = 720.9 + 0.95 × 2046.5 – 4.18 × 25
temperature was 61°C, the boiler gauge pressure 5 bar, and = 720.9 + 1944.2 – 104.5
dryness of steam 0.95. The calorific value of carbon is 33700 = 2560.6 kJ/kg
kJ/kg and that of hydrogen, 144600 kJ/kg. Heat supplied per hour
Solution. Boiler gauge pressure= 5 bar = 2560.6 × 360 kJ
Boiler absolute pressure = 5 + 1 = 6 bar Calorific value of coal
Dryness fraction of steam, x = 0.95 = 33800 C + 144000 (H – 0/8) + 9270 S
Feed water temperature = 61°C FG IJ
0.1
Quantity of steam produced = 2250 kg/h H
= 33800 × 0.7 + 144000 0.50
8K
Coal consumption = 225 kg/h + 9270 × 0.02
= 23660 + 5400 + 185.4 = 29245.4
From steam tables, corresponding to 6 bar
Total heat input
hf = 670.4 kJ/kg
= 60 × 29245.4 kJ
hfg = 2085 kJ/kg
2560.6 360
Heat of 1 kg of the steam, boiler = × 100
60 29245.4
H = hf + xhfg = 670.4 + 0.95 × 2085 = 52.53%. (Ans.)
INTRODUCTION 17
Example 1.13. A water gas at 21°C and 1.033 bar is burned showed CO2 = 15.5%, O2 = 4.76% and CO = 0.2%. Find the
with dry air supplied at 21°C and 1.033 bar. The fuel gas percentage of excess air supplied for combustion and the
composition is CO2 = 6%, N2 = 5.5%, H2 = 48%, O2 = 0.5%, volume of the flue gas at 232°C and 1.03 bar formed per m3
CH4 = 2%, CO = 38%. The orsat analysis of the flue gas of the fuel.
HIGHLIGHTS
1. Energy appears in many forms, but has one thing in 3. A chemical fuel is a substance which releases heat energy
common—energy is possessed of the ability to produce a on combustion. The principal element of each fuel are
dynamic, vital effect. carbon and hydrogen. Though sulphur is a combustible
2. Sources of energy are : element too but its presence in the fuel is considered to be
(i) Fuels (ii) Energy stored in water undesirable.
(iii) Nuclear energy (iv) Wind power 4. The principal types of power plants are :
(v) Solar energy (vi) Tidal power (i) Steam plants using coal, oil or nuclear fission
(vii) Geothermal energy (viii) Thermoelectric power. (ii) Internal combustion engine plants
18 POWER PLANT ENGINEERING
(iii) Gas turbine plants and carbon monoxide present in 1 kg of flue or exhaust
(iv) Hydro-electric plants. gas.
5. The weight of excess air supplied can be determined from The weight of flue gas/kg of fuel burnt
the weight of oxygen which is left unused. Weight of carbon in one kg of fuel
= .
3 3 Weight of carbon in one kg of flue gas
6. The weight of carbon per kg of fuel = CO2 + CO
11 7
where CO2 and CO are the quantities of carbon dioxide
THEORETICAL QUESTIONS
1. Enumerate sources of energy. 7. What are the advantages of gaseous fuels ?
2. What is a chemical fuel ? How does it differ from a nuclear 8. State the factors which go in favour of nuclear energy.
fuel ? 9. Write short notes on :
3. How are chemical fuels classified ? Tidal power, wind power and thermoelectric power.
4. Explain briefly the following solid fuels : 10. Name the principal types of power plants.
Lignites and brown coals, bituminous coal and coke. 11. Why do we feel the necessity of using excess air for burning
5. List the advantages of liquid fuels. fuels ?
6. Describe the following gaseous fuels : 12. How can the following be calculated ?
Coal gas, Coke-oven gas, Blast furnace gas and Producer (i) Weight of carbon in flue gases.
gas. (ii) Weight of flue gas per kg of fuel burnt.
UNSOLVED EXAMPLES
1. A fuel has the following composition by weight : Carbon = 6. The percentage composition by mass of a crude oil is given
86% ; hydrogen = 11.75% and oxygen = 2.25%. Calculate as follows : C = 90%, H2 = 3.3%, O2 = 3%, N2 = 0.8% ;
the theoretical air supply per kg of fuel, and the weight of S = 0.9% and remaining incombustible. If 50% excess air
products of combustion per kg of fuel. is supplied, find the percentages of dry exhaust gases found
[Ans. 13.98 kg ; 4.21 kg] by volume.
[Ans. CO2 = 12.7% ; SO2 = 0.05% ; O2 = 7%, N2 = 80.25%]
2. The volumetric analysis of a fuel gas is : CO2 = 14% ; CO =
1% ; O2 = 5% and N2 = 80%. Calculate the fuel gas 7. In a boiler trial, the analysis of the coal used is as follows :
composition by weight. C = 20%, H2 = 4.5%, O2 = 7.5%, remainder-incombustible
matter.
[Ans. 20.24% ; 0.93% ; 5.25% ; 73.58%] The dry flue gas has the following composition by volume :
3. The ultimate analysis of a dry coal burnt in a boiler gauge CO2 = 8.5%, CO = 1.2%, N2 = 80.3%, O2 = 10% determine :
C = 84% ; H2 = 9% and incombustibles 7% by weight.
(i) Minimum weight of air required per kg of coal.
Determine the weight of dry flue gases per kg of coal burnt,
if volumetric combustion of the flue gas is : CO2 = 8.75%, (ii) Percentage excess air. [Ans. (i) 3.56 kg, (ii) 63.2%]
CO = 2.25% ; O2 = 8% and N2 = 81%. [Ans. 18.92 kg] 8. The ultimate analysis of a sample of petrol by weight is :
Carbon = 0.835 ; hydrogen = 0.165. Calculate the ratio of
4. During a trial in a boiler, the dry flue gas analysis by air to petrol consumption by weight, if the volumetric
volume was obtained as CO2 = 13%, CO = 0.3%, analysis of the dry exhaust gas is : Carbon dioxide = 12.1 ;
O2 = 6%, N2 = 80.7%. The coal analysis by weight was carbon monoxide = 1.1 ; oxygen = 0.8 ; nitrogen = 85.4%.
reported as C = 62.4%, H2 = 4.2%, O2 = 4.5%, moisture = Also find the percentage excess air.
15% and ash = 13.9%. Estimate :
[Ans. 16.265 : 1 ; 5.6%]
(a) Theoretical air required to burn 1 kg of coal. 9. The percentage composition of a sample of fuel was found
(b) Weight of air actually supplied per kg of coal, and to be C = 85%, H2 = 9%, S = 3%, O2 = 1.5%, Ash = 1.5%. For
(c) The amount of excess air supplied per kg of coal burnt. an air-fuel ratio of 12 : 1, calculate (i) the mixture strength
as a percentage rich or weak, (ii) the volumetric analysis
[Ans. (a) 8.5 kg ; (b) 11.5 kg ; (c) 3 kg]
of the dry products of combustion.
5. A steam boiler uses pulverised coal in the furnace. The [Ans. 8.83% rich ; CO2 = 12.16%, CO = 2.54%,
ultimate analysis of coal (by weight) as received is : C = N2 = 84.83%, SO2 = 0.47%]
78% ; H2 = 3% ; O2 = 3% ; ash = 10% and moisture = 5%.
10. The ultimate analysis of fuel used in a boiler is given as
Excess air supplied is 30%. Calculate the weight of air to
follows : C = 87%, H2 = 4%, O2 = 3.5% and the remainder
be supplied and weight of gaseous product formed per kg
is ash. The volume of CO2 in the exhaust gases noted by
of coal burnt.
CO2 recorder is 12.5%.
[Ans. 13 kg ; CO2 = 2.86 kg ; H2 = 0.27 kg ; excess O2 = Find the percentage excess air supplied per kg of fuel.
0.69 kg and N2 = 9.81 kg per kg of coal] [Ans. 51.95%]
INTRODUCTION 19
11. The ultimate analysis of coal used in a boiler is given as 13. The volumetric analysis of exhaust gases of an oil engine
follows : is : CO2 = 15%, CO = 2.2%, O2 = 1.6%, Nitrogen = 81.2%.
C = 82%, H2 = 5.4%, O2 = 7%, N2 = 0.5%, S = 0.6%, moisture Convert this analysis into analysis by weight.
= 1% and the remainder is ash. [Ans. CO2 = 21.6%, CO = 2.2%, O2 = 1.7%, N2 = 74.5%]
The volumetric analysis of the exhaust gases determined
14. The dry exhaust gas from an oil engine had the following
by Orsat apparatus is given as follows :
percentage composition by volume :
CO2 = 9.6%, CO = 1.2%, O2 = 7.8% and N2 = 81.4%.
CO2 = 8.85%, CO = 1.2%, O2 = 6.8%, N2 = 83.15%.
From fundamental determine the percentage of excess air
The fuel had the percentage composition by weight as
supplied to the furnace of the boiler. [Ans. 57%]
follows : C = 84%, H2 = 14%, O2 = 2%.
12. The percentage composition of a sample of crude oil was
Determine the weight of air supplied per kg of fuel burnt.
found by analysis to be :
C = 90%, H2 = 3.3%, O2 = 3%, N2 = 0.8%, S = 0.9%, [Ans. 21.08 kg]
Ash = 2% 15. In a boiler trial, the fuel used has the following analysis
by weight : C = 85%, H2 = 4% and ash = 11%. If the flue
If 50% excess air is supplied, find the percentage
gas analysis gave CO2 = 12%, O2 = 8% and nitrogen = 80%
composition of the dry flue gases by volume.
by volume, find per kg of dry fuel :
[Ans. CO2 = 12.69%, SO2 = 0.05%,
(i) Weight of necessary air.
O2 = 7%, N2 = 80.26%]
(ii) Weight of excess air. [Ans. (i) 11.25 kg, (ii) 6.57 kg]
Power Plant Cycles 2
2.1. Introduction. 2.2. Classification of power plant cycles. 2.3. Carnot cycle. 2.4. Rankine cycle. 2.5. Modified rankine cycle.
2.6. Reheat cycle. 2.7. Regenerative cycle. 2.8. Binary vapour cycle. 2.9. Otto cycle. 2.10. Diesel cycle. 2.11. Dual combustion
cycle 2.12. Gas turbine cycles—Highlights—Theoretical Questions—Unsolved Examples.
20
POWER PLANT CYCLES 21
1
p2 Q1
3 2
v Boiler Turbine WT(=Wout)
(Qin)
Fig. 2.1. Carnot cycle on T-s and p-v diagrams.
2
Heat rejected at constant temperature T2 (operation
2–3) = Area 2–3-a-b = T2 (s2 – s3). Condenser
Since there is no exchange of heat during isentropic Cooling
water
operations (1–2) and (3–4), therefore, 4
Wp 3 Q2(= Qout)
Net work done = Heat supplied – heat rejected
(= Win)
= T1 (s2 – s3) – T2 (s2 – s3) Feed pump
= (T1 – T2) (s2 – s3).
Fig. 2.2. Rankine cycle.
Work done
Carnot cycle =
Heat supplied
p
(T1 T2 ) ( s2 s3 ) T1 T2
= =
T1 ( s2 s3 ) T1
...(2.1)
Limitations of Carnot cycle: 4 1¢ 1 1¢¢
p1 Superheated steam
Though Carnot cycle is simple (thermodynamically)
and has the highest thermal efficiency for given values of Dry saturated steam
T1 and T2, yet it is extremely difficult to operate in practice Wet
because of the following reasons : steam
1. It is difficult to compress a wet vapour isentropi- 3
cally to the saturated state as required by the process 3–4. p2 2¢ 2 2¢¢
v
(a)
22 POWER PLANT ENGINEERING
Q1 = h1 – hf4 ...(2.2)
T
(ii) For turbine (as control volume), we get:
1¢¢ h1 = WT + h2, where WT = turbine work
WT = h1 – h2 ...(2.3)
1¢ 1 (iii) For condenser, we get:
p1 h2 = Q2 + hf3
Q2 = h2 – hf3 ...(2.4)
4
(iv) For the feed pump, we get:
The Rankine cycle is shown in Fig. 2.2. It consists or hf4 – hf3 = v3 (p1 – p2)
of the following processes : When p is in bar and v is in m3/kg, we have:
Process 1–2 : Reversible adiabatic expansion in the
hf4 – hf3 = v3 (p1 – p2) × 105 J/kg
turbine (or steam engine).
Process 2–3 : Constant-pressure transfer of heat The feed pump term ( hf4 – hf3 ) being a small
in the condenser. quantity in comparison with turbine work, WT is usually
Process 3–4 : Reversible adiabatic pumping process neglected, especially when the boiler pressures are low.
in the feed pump.
h1 h2
Process 4–1 : Constant-pressure transfer of heat Then, Rankine = ...[2.5 (a)]
h1 hf4
in the boiler.
Fig. 2.3 shows the Rankine cycle on p-v, T-s and Comparison between Rankine cycle and Carnot
h-s diagrams (when the saturated steam enters the turbine, cycle :
the steam can be wet or superheated also). The following points are worth noting :
Consider 1 kg of fluid : (i) Between the same temperature limits Rankine
cycle provides a higher specific work output than
Applying steady flow energy equation (S.F.E.E.) to
a Carnot cycle, consequently Rankine cycle
boiler, turbine, condenser and pump, we have :
requires a smaller steam flow rate resulting in
(i) For boiler (as control volume), we get: smaller size plant for a given power output.
hf4 + Q1 = h1 However, Rankine cycle calls for higher rates of
heat transfer in boiler and condenser.
POWER PLANT CYCLES 23
(ii) Since in Rankine cycle only part of the heat is (ii) Decreasing/reducing the temperature at which
supplied isothermally at constant higher tem- heat is rejected.
perature T1, therefore, its efficiency is lower than This can be achieved by making suitable changes
that of Carnot cycle. The efficiency of the Rank- in the conditions of steam generation or condensation, as
ine cycle will approach that of the Carnot cycle discussed below :
more nearly if the superheat temperature rise is 1. Increasing boiler pressure. It has been ob-
reduced. served that by increasing the boiler pressure (other fac-
(iii) The advantage of using pump to feed liquid to tors remaining the same) the cycle tends to rise and reaches
the boiler instead to compressing a wet vapour a maximum value at a boiler pressure of about 166 bar
is obvious that the work for compression is very [Fig. 2.5 (a)].
large compared to the pump.
2. Superheating. All other factors remaining the
Fig. 2.4 shows the plots between efficiency and same, if the steam is superheated before allowing it to
specific steam consumption against boiler pressure for expand the Rankine cycle efficiency may be increased
Carnot and ideal Rankine cycles. [Fig. 2.5 (b)]. The use of superheated steam also ensures
Effect of operating conditions on Rankine cycle longer turbine blade life because of the absence of erosion
efficiency : from high velocity water particles that are suspended in
wet vapour.
The Rankine cycle efficiency can be improved by :
3. Reducing condenser pressure. The thermal
(i) Increasing the average temperature at which
efficiency of the cycle can be amply improved by reducing
heat is supplied.
the condenser pressure [Fig. 2.5 (c)] (hence by reducing
the temperature at which heat is rejected), especially in
80 high vacuums. But the increase in efficiency is obtained at
70 cle the increased cost of condensation apparatus.
t cy
no
60 C ar
cle
50 e cy
nkin
40 Ra
%h
30
Efficiency
20
10
0 50 100 150 200 225
166
Boiler pressure (bar)
(a) Boiler pressure (bar)
(a)
Specific steam consumption (kg/kWh)
12
10
Efficiency ¾¾®
8
cle
ot cy
6 Carn
4 Rankine cycle
2
0 50 100 150 200 225
Degree of superheat
Boiler pressure (bar)
(b) (b)
Fig. 2.4
24 POWER PLANT ENGINEERING
Condenser pressure
(c)
Fig. 2.5. Effect of operating conditions on the thermal
efficiency of the Rankine cycle.
+Example 2.1. The following data refer to a simple steam power plant :
S. No. Location Pressure Quality/temp. Velocity
ha =
b g
3177.2 60 bar 3158.1 70 barb g Condenser pressure,
Rankine efficiency :
p2 = 0.06 bar
2
= 3167.6 kJ/kg From steam tables,
......(By interpolation) At 15 bar, 350°C : h = 3147.5 kJ/kg,
Heat transfer per hour in the boiler, s = 7.102 kJ/kg K
Q1 = 10000 (ha – hf ) kJ/h At 0.06 bar : hf = 151.5 kJ/kg,
4
Now, s1 = s 2
6.9917 = sf b p g + x2 sfg b p g 28 bar 1
2 2
5
= 0.5926 + x2 × 7.6361
6.9917 0.5926
x2 = = 0.838
7.6361
h2 = hf b p g + x2 hfg b p g 4
2 2
3
= 173.88 + 0.838 × 2403.1 2
0.06 bar
= 2187.68 kJ/kg.
Net work, Wnet :
Wnet = Wturbine – Wpump ...(i)
s
Wpump = hf – hf b p g (= hf )
4 2 3
Fig. 2.8
= vf b p2 g (p1 – p2)
Considering turbine process 1–2, we have :
= 0.00108 (m3/kg) × (20 – 0.08)
s1 = s2
× 100 kN/m2
= 2.008 kJ/kg 6.2104 = sf2 + x2 sfg2
[and hf4 = 2.008 + h = 2.008 + 173.88
f b p2 g = 0.521 + x2 × 7.809
= 175.89 kJ/kg]
6.2104 0.521
Wturbine = h1 – h2 = 3153.9 – 2187.68 x2 = = 0.728
= 971.62 kJ/kg 7.809
Wnet = 971.62 – 2.008 h2 = hf2 + x2 hfg2
= 969.61 kJ/kg. (Ans.)
= 151.5 + 0.728 × 2415.9
Q1 = h1 – hf = 3159.3 – 175.89
4 = 1910.27 kJ/kg
= 2983.41 kJ/kg Turbine work,
W 969.61
cycle = net = Wturbine = h1 – h2 = 2802 – 1910.27
Q1 2983.41
= 0.325 or 32.5%. (Ans.) = 891.73 kJ/kg
POWER PLANT CYCLES 27
Pump work, T
=
b g
0.001 28 0.06 105
5
35 bar 1
1000
= 2.79 kJ/kg
[ ∵ hf4 = hf3 + 2.79 = 151.5 + 2.79
= 154.29 kJ/kg]
Net work, 4
0.2 bar
3
Wnet = Wturbine – Wpump 2
(iii) The indicated and brake work per kg. During isentropic expansion 1–2, we have:
(iv) The brake thermal efficiency. s1 = s2
(v) The relative efficiency on the basis of indicated 6.918 = sf2 + x2 sfg2
work and brake work. = 1.5301 + x2 × 5.5967
Solution. Fig. 2.12 shows the p-v and T-s diagrams for 6.918 1.5301
x2 = = 0.96.
modified Rankine cycle. 5.5967
From steam tables : Then h2 = hf2 + x2 hfg = 504.7 + 0.96 × 2201.6
2
1. At 15 bar, 300°C : h1 = 3037.6 kJ/kg,
= 2618.2 kJ/kg
v1 = 0.169 m3/kg,
v2 = x2 vg2 + (1 – x2) vf2
s = 6.918 kJ/kg K.
2. At 2 bar : ts = 120.2°C, = 0.96 × 0.885 + (1 – 0.96) × 0.00106
hf = 504.7 kJ/kg, = 0.849 m3/kg.
hfg = 2201.6 kJ/kg, (i) Ideal work :
sf = 1.5301 kJ/kg K, Ideal work or modified Rankine engine work/kg,
sfg = 5.5967 kJ/kg K, W = (h1 – h2) + (p2 – p3) v2
vf = 0.00106 m3/kg, = (3037.6 – 2618.2) + (2 – 1.1) × 105
vg = 0.885 m3/kg.
× 0.849/1000
3. At 1.1 bar : ts = 102.3°C,
= 419.4 + 76.41 = 495.8 kJ/kg. (Ans.)
hf = 428.8 kJ/kg,
hfg = 2250.8 kJ/kg, (ii) Rankine engine efficiency :
sf = 1.333 kJ/kg K, Work done 495.8
rankine = =
sfg = 5.9947 kJ/kg K, Heat supplied (h1 hf3 )
vf = 0.001 m3/kg, 495.8
vg = 1.549 m3/kg. = = 0.19 or 19%. (Ans.)
3037.6 428.8
p (iii) Indicated and brake, work per kg :
Indicated work/kg,
I.P.
p1 1 (15 bar, 300°C) Windicated =
m
1 3600
= = 281.25 kJ/kg. (Ans.)
12.8
2 (2 bar) Brake work/kg,
p2
B.P. mech. I.P.
p3 3 (1.1 bar) Wbrake = =
m m
v
v2 0.8 1 3600
=
12.8
(a)
= 225 kJ/kg. (Ans.)
T (iv) Brake thermal efficiency :
Brake thermal efficiency
Wbrake 225
1 = =
h1 hf 3037.6 428.8
3
= 0.086 or 8.6%. (Ans.)
(v) Relative efficiency :
2 Relative efficiency on the basis of indicated work
3 Windicated
s h1 hf Windicated
3
= =
W W
(b)
h1 hf
3
Fig. 2.12
30 POWER PLANT ENGINEERING
p
281.25
= = 0.567 or 56.7%. (Ans.)
495.8
Relative efficiency on the basis of brake work 1
Wbrake p1
(h1 hf3 ) W (10 bar) Loss of work due
= W = brake 400ºC to incomplete
W expansion
(h1 hf3 )
225 p2
= = 0.4538 or 45.38%. (Ans.) 2
495.8 (0.9 bar)
Example 2.7. Superheated steam at a pressure of 10 bar p3
2¢
and 400°C is supplied to a steam engine. Adiabatic expan- (0.3 bar) 3
v
sion takes place to release point at 0.9 bar and it exhausts
into a condenser at 0.3 bar. Neglecting clearance determine
T
for a steam flow rate of 1.5 kg/s :
(i) Quality of steam at the end of expansion and the 1
end of constant volume operation.
(ii) Power developed. 10 bar
(iii) Specific steam consumption.
(iv) Modified Rankine cycle efficiency.
Solution. Fig. 2.13 shows the p-v and T-s diagrams for 0.9 bar
modified Rankine cycle. 2
From steam tables : 0.3 bar
3 2¢
1. At 10 bar, 400C : h1 = 3263.9 kJ/kg, Constant volume line s
v1 = 0.307 m3/kg,
s1 = 7.465 kJ/kg K Fig. 2.13. p-v and T-s diagrams.
2. At 0.9 bar : ts2 = 96.7°C,
or tsup2 = 382 – 273 = 109C. (Ans.)
hg2 = 2670.9 kJ/kg,
h2 = hg2 + cps (Tsup2 – Ts2 )
sg2 = 7.3954 kJ/kg K,
= 2670.9 + 2.1 (382 – 366.5)
vg2 = 1.869 m3/kg = 2703.4 kJ/kg. (Ans.)
3. At 0.3 bar : hf3 = 289.3 kJ/kg, (b) Quality of steam at the end of constant
volume operation, x3 :
vg3 = 5.229 m3/kg For calculating v2 using the relation:
(i) (a) Quality of steam at the end of expansion,
Tsup2 : vg2 v2
= (Approximately), we get:
For isentropic expansion 1–2, we have: Ts2 Tsup2
s1 = s2
T 1.869 v
= sg2 + cp loge sup 2 = 2
Ts2 369.7 382
1.869 382
Tsup2 or, v2 = = 1.931 m3/kg
7.465 = 7.3954 + 2.1 loge 369.7
(96.7 273)
Also, v2 = v3 = x3 vg3
FG 7.465 7.3954 IJ = log Tsup2
H 2.1 K e 369.7 1.931 = x3 × 5.229
1.931
Tsup2 or, x3 = = 0.37. (Ans.)
or, loge = 0.03314 5.229
369.7
(ii) Power developed, P :
Tsup2
= 1.0337 or Tsup2 = 382 K Work done = (h1 – h2) + (p2 – p3) v2
369.7
POWER PLANT CYCLES 31
= (3263.9 – 2703.4) 46
hRankine (%)
= Steam flow rate × work done (per kg) 40
ar
ba
Advantages of Superheated steam : Superheat line
4b
15
3 250ºC
1. Superheating reduces the initial condensation 2960
losses in steam engines. 1 ng
2. Use of superheated steam results in improving 2920 eati
Reh
the plant efficiency by effecting a saving in cost of fuel. This Saturation line
saving may be of the order of 6% to 7% due to first 38°C of
2660
r
ba
superheat and 4% to 5% for next 38°C and so on. This sav- 2
1
ing results due to the fact that the heat content and conse-
0.
quently the capacity to do work in superheated steam is
increased and the quantity of steam required for a given
output of power is reduced. Although additional heat has
2335
to be added in the boiler there is reduction in the work to 4
be done by the feed pump, the condenser pump and other
accessories due to reduction in quantity of steam used. It 2125
4¢
s (kJ/kg K)
is estimated that the quantity of steam may be reduced by
10% to 15% for first 38°C of superheat and some what less Fig. 2.17
for the next 38°C of superheat in the case of condensing
turbines. Amount of heat supplied during reheat,
hreheat = (2960 – 2660) = 300 kJ/kg. (Ans.)
3. When a superheater is used in a boiler it helps in
reducing the stack temperatures by extracting heat from If the expansion would have been continuous with-
the flue gases before these are passed out of chimney. out reheating i.e., 1 to 4, the work output is given by:
W1 = h1 – h4
+Example 2.8. Steam at a pressure of 15 bar abs. and From Mollier diagram,
250C is expanded through a turbine at first to a pressure h4 = 2125 kJ/kg
of 4 bar abs. It is then reheated at constant pressure to the W1 = 2920 – 2125 = 795 kJ/kg. (Ans.)
initial temperature of 250C and is finally expanded to 0.1
Example 2.9. A turbine is supplied with steam at a pressure
bar abs. Using Mollier chart, estimate the work done per kg
of 32 bar and a temperature of 410C. The steam then
of steam flowing through the turbine and amount of heat
expands isentropically to a pressure of 0.08 bar. Find the
supplied during the process of reheat. Compare the work
dryness fraction at the end of expansion and thermal
output when the expansion is direct from 15 bar abs. to 0.1
efficiency of the cycle.
bar abs. without any reheat. Assume all expansion processes
to be isentropic. If the steam is reheated at 5.5 bar to a temperature
of 400C and then expanded isentropically to a pressure of
Solution. Refer to Fig. 2.17.
0.08 bar, what will be the dryness fraction and thermal
Pressure, p1 = 15 bar ; efficiency of the cycle ?
p2 = 4 bar ; Solution. First case. Refer to Fig. 2.18.
p4 = 0.1 bar.
h(kJ/kg)
Work done per kg of steam,
W = Total heat drop
r
ba
1 0 ba
ba
ar 4
32
5.b 3
1 410ºC
3 5. 400ºC
2
bar
2 0.08
x4 = 0.935
4
s s
T-s diagram
(b)
(a)
Fig. 2.19
POWER PLANT CYCLES 35
h
2.7. REGENERATIVE CYCLE
In the Rankine cycle it is observed that the condensate
1 3 which is fairly at low temperature has an irreversible
550ºC
mixing with hot boiler water and this results in decrease
150 bar of cycle efficiency. Methods are, therefore, adopted to heat
the feed water from the hot well of condenser irreversibly
by interchange of heat within the system and thus
improving the cycle efficiency. This heating method is called
40 bar 2
regenerative feed heat and the cycle is called regenerative
cycle.
The principle of regeneration can be practically
4
0.1 bar utilised by extracting steam from the turbine at several
locations and supplying it to the regenerative heaters. The
s resulting cycle is known as regenerative or bleeding cycle.
h-s diagram The heating arrangement comprises of : (i) For medium
(b) capacity turbines—not more than 3 heaters ; (ii) For high
pressure high capacity turbines—not more than 5 to 7
Fig. 2.20
heaters ; and (iii) For turbines of supercritical parameters
From Mollier diagram (h-s diagram) : 8 to 9 heaters. The most advantageous condensate heating
h1 = 3450 kJ/kg ; temperature is selected depending on the turbine throttle
conditions and this determines the number of heaters to be
h2 = 3050 kJ/kg ; used. The final condensate heating temperature is kept 50
h3 = 3560 kJ/kg ; to 60°C below the boiler saturated steam temperature so
as to prevent evaporation of water in the feed mains
h4 = 2300 kJ/kg
following a drop in the boiler drum pressure. The conditions
hf4 (from steam tables, at 0.1 bar) of steam bled for each heater are selected so that the
temperature of saturated steam will be 4 to 10°C higher
= 191.8 kJ/kg
than the final condensate temperature.
(i) Quality of steam at turbine exhaust, x4 : Fig. 2.21 (a) shows a diagrammatic layout of a
x4 = 0.88 (From Mollier diagram) condensing steam power plant in which a surface condenser
(Ans.) is used to condense all the steam that is not extracted for
feed water heating. The turbine is double extracting and
(ii) Cycle efficiency, cycle : the boiler is equipped with a superheater. The cycle
(h1 h2 ) (h3 h4 ) diagram (T-s) would appear as shown in Fig. 2.21 (b). This
cycle = arrangement constitutes a regenerative cycle.
(h1 hf4 ) (h3 h2 )
1
POWER PLANT CYCLES 37
(i) The efficiency and the steam rate of the cycle. From steam tables :
(ii) The increase in mean temperature of heat At 30 bar, 400C : h1 = 3230.9 kJ/kg,
addition, efficiency and steam rate as compared to the s1 = 6.921 kJ/kg K = s2 = s3,
Rankine cycle (without regeneration). At 5 bar : sf = 1.8604 kJ/kg K,
Pump work may be neglected. sg = 6.8192 kJ/kg K,
Solution. Fig. 2.22 shows the flow, T-s and h-s diagrams. hf = 640.1 kJ/kg
Since s2 sg, the state 2 must lie in the superheated
1 kg 1 region. From the table for superheated steam
Turbine Power output
30 bar, 400ºC t2 = 172°C,
h2 = 2796 kJ/kg.
Boiler 2 At 0.1 bar : sf = 0.649 kJ/kg K,
(1 – m) kg
5 bar m kg sf g = 7.501 kJ/kg K,
3 0.1 bar
Condenser hf = 191.8 kJ/kg K,
Heater
hf g = 2392.8 kJ/kg K.
6
7 Now, s2 = s3
4
5
Pump
i.e., 6.921 = sf3 + x3 sfg3
1 kg (1 – m)kg
Pump = 0.649 + x3 × 7.501
(a)
T 6.921 0.649
x3 = = 0.836
7.501
h3 = hf3 + x3 hfg3
1 (400ºC)
= 191.8 + 0.836 × 2392.8
30 bar 1 kg = 2192.2 kJ/kg
1 kg Since pump work is neglected
7
5 bar
2 hf4 = 191.8 kJ/kg = hf5
6 m kg hf6 = 640.1 (at 5 bar) = hf7
5
(1 – m)kg Energy balance for heater gives
0.1 bar m (h2 – hf6 ) = (1 – m) ( hf – hf )
6 5
4 3
(1 – m) kg m (2796 – 640.1) = (1 – m) (640.1 – 191.8)
s = 448.3 (1 – m)
(b)
h
2155.9 m = 448.3 – 448.3 m
m = 0.172 kg
Turbine work,
1 (400ºC)
WT = (h1 – h2) + (1 – m) (h2 – h3)
1 kg = (3230.9 – 2796)
+ (1 – 0.172) (2796 – 2192.2)
2 = 434.9 + 499.9 = 934.8 kJ/kg
kg
r 1 (1–m) kg Heat supplied, Q1 = h1 – hf6 = 3230.9 – 640.1
ba
30 = 2590.8 kJ/kg.
7 ar
5 b kg
m WT 934.8
5 3 (i) cycle = =
6 0.1 bar Q1 2590.8
4 (1–m) kg
= 0.3608 or 36.08%. (Ans.)
s
3600
(c) Steam rate = = 3.85 kg/kWh. (Ans.)
934.8
Fig. 2.22
38 POWER PLANT ENGINEERING
h1 hf7 2590.8 h
C
(ii) Tm1 = =
0º
6.921 1.8604
35
s1 s7
r,
= 511.9 K = 238.9°C.
ba
30
08 ar
r
Tm1 (without regeneration)
r
b
ba
ba
0
0
1.
5
h1 hf4
0.
3230.9 191.8
= =
s1 s4 6.921 0.649 1
3039.1 2
= = 484.5 K = 211.5°C.
6.272
3
Increase in Tm due to regeneration
1
hf1 hf2
1 kg m1 =
Turbine h1 hf1
0 1– m1– m2 640.1 417.5
1 1 – m1 1– m1– m2 =
2 3 2720 640.1
m1 , h 1 Condenser = 0.107 kJ/kg of
m2 , h 2
hf3 entering steam. (Ans.)
1 kg hf2 hf4 hf3 At heater No. 2 :
1 kg
m2h2 + m1 hf + hf4 = (m1 + m2) hf2 + hf2 ...(i)
hf1 1
At drain cooler :
Heater-1 m1 m1 + m2 Drain cooler (m1 + m2) hf2 + hf3 = hf4 + (m1 + m2) hf
3
Heater-2
hf4 = (m1 + m2) ( hf – hf3 ) + hf3 ...(ii)
2
(a)
POWER PLANT CYCLES 39
Inserting the value of hf in eqn. (i), we get: Solution. Refer to Fig. 2.24 (a), (b).
4
= (m1 + m2) hf + hf 1 kg
2 2 T u r b i n e
m2h2 + m1 hf + (m1 + m2) hf – (m1 + m2) hf + hf 0 1
1 2 3 3 2
3
= (m1 + m2) hf + hf 1 – m1
1 – m1 – m 2 4
2 2
1 – m1 – m 2 – m 3
m2h2 + m1 hf1 – m1 hf3 – m2 hf3 + hf3 = hf2
m1, h1 m2, h2 m3, h3
m2 (h2 – hf3 ) = ( hf2 – hf3 ) – m1( hf1 – hf3 )
(hf2 hf3 ) m1 (hf1 hf3 ) m1 + m2 + m3 Condenser
m2 = 1 2 3 hf4 1 kg, hf4
(h2 hf3 ) 1 kg
(2450 – 2120)
m 1)
= 395.3 + 241.11 + 266.64 = 903.05 kJ/kg 1 (1 –
ºC
50
Heat supplied/kg = h0 – hf1 r,
2 )
m2
ba – )
3
= 3115.3 – 640.1 = 2475.2 kJ/kg 20 2 –
m1 –m
r (1 m2
ba –
Thermal efficiency of the cycle 5.
0
r –m
1
a 3 (1
5b
Work done 903.05 1.
ba
r
4
= = 0.3 bar
Heat supplied 2475.2 0.0
5
= 0.3648 or 36.48%. (Ans.) s
+Example 2.13. Steam at a pressure of 20 bar and 250°C (b)
226 bar (approx.) which will create many difficulties in and forms a serious resistance to heat flow. This difficulty
design, operation and control. It would be desirable to use can be considerably reduced by adding magnesium and
some fluid other than steam which has more desirable ther- titanium (2 parts in 100000 parts) in mercury.
modynamic properties than water. An ideal fluid for this
purpose should have a very high critical temperature com- Thermal properties of mercury :
bined with low pressure. Mercury, diphenyloxide and simi- Mercury fulfils practically all the desirable thermo-
lar compounds, aluminium bromide and zinc ammonium dynamic properties stated above.
chloride are fluids which possess the required properties
1. Its freezing point is – 3.3°C and boiling point is
in varying degrees. Mercury is the only working fluid which
– 354.4°C at atmospheric pressure.
has been successfully used in practice. It has high critical
temperature (588.4°C) and correspondingly low critical 2. The pressure required when the temperature of
pressure (21 bar abs.). The mercury alone cannot be used vapour is 540°C is only 12.5 bar (approx.) and,
as its saturation temperature at atmospheric pressure is therefore, heavy construction is not required to
high (357C). Hence binary vapour cycle is generally used get high initial temperature.
to increase the overall efficiency of the plant. Two fluids 3. Its liquid saturation curve is very steep,
(mercury and water) are used in cascade in the binary cycle approaching the isentropic of the Carnot cycle.
for production of power. 4. It has no corrosive or erosive effects upon metals
The few more properties required for an ideal binary commonly used in practice.
fluid used in high temperature limit are listed below : 5. Its critical temperature is so far removed from
1. It should have high critical temperature at any possible upper temperature limit with
reasonably low pressure. existing metals as to cause no trouble.
2. It should have high heat of vaporisation to keep Some undesirable properties of mercury are listed
the weight of fluid in the cycle to minimum. below :
3. Freezing temperature should be below room 1. Since the latent heat of mercury is quite low over
temperature. a wide range of desirable condensation
4. It should have chemical stability throughout the temperatures, therefore, several kg of mercury
working cycle. must be circulated per kg of water evaporated
5. It must be non-corrosive to the metals normally in binary cycle.
used in power plants. 2. The cost is a considerable item as the quantity
6. It must have an ability to wet the metal surfaces required is 8 to 10 times the quantity of water
to promote the heat transfer. circulated in binary system.
7. The vapour pressure at a desirable condensation 3. Mercury vapour in large quantities is poisonous,
temperature should be nearly atmospheric which therefore, the system must be perfect and tight.
will eliminate requirement of power for Fig. 2.25 shows the schematic line diagram of binary
maintenance of vacuum in the condenser. vapour cycle using mercury and water as working fluids.
8. After expansion through the prime mover the The processes are represented on T-s diagram as shown in
vapour should be nearly saturated so that a Fig. 2.26.
desirable heat transfer co-efficient can be
obtained which will reduce the size of the Mercury Mercury electric Steam electric
turbine
condenser required. generator Steam generator
turbine
9. It must be available in large quantities at
reasonable cost.
10. It should not be toxic and, therefore, dangerous
Superheater
to human life. Mercury
Steam
condenser
Although mercury does not have all the required generator
Mercury condenser or
properties, it is more favourable than any other fluid Steam generator
investigated. It is most stable under all operating conditions.
Although, mercury does not cause any corrosion to
metals, but it is extremely dangerous to human life, Mercury feed pump Water feed pump
therefore, elaborate precautions must be taken to prevent
the escape of vapour. The major disadvantage associated Fig. 2.25. Line diagram of binary vapour cycle.
with mercury is that it does not wet surface of the metal
42 POWER PLANT ENGINEERING
hhg2 = Heat lost by one kg of Hg vapour in the The thermal efficiency of the steam cycle is given
by:
mercury condenser.
Ws hs hs2 hs hs2
hs = Heat given per kg of steam generated in the s = = 1 = 1 ...(2.23)
hs hs1 m hhg2
mercury condenser or steam boiler.
Whg = Work done per kg of Hg in the cycle. From the equations (2.18), (2.20), (2.21), (2.22) and
(2.23), we get
Ws = Work done per kg of steam in the steam
= hg (1 – s) + s ...(2.24)
cycle.
To solve the problems eqns. (2.19), (2.23), (2.24) are
s = Thermal efficiency of the steam cycle. used.
hg = Thermal efficiency of the Hg cycle. In the design of binary cycle, another important
m = Mass of Hg in the Hg cycle per kg of steam problem is the limit of exhaust pressure of the mercury
circulated in the steam cycle. (location of optimum exhaust pressure) which will provide
The heat losses to the surroundings, in the following maximum work per kg of Hg circulated in the system and
analysis, are neglected and steam generated is considered high thermal efficiency of the cycle. It is not easy to decide
one kg and Hg in the circuit is m kg per kg of water in the as number of controlling factors are many.
steam cycle.
+Example 2.14. A binary vapour cycle operates on
Heat supplied in the Hg boiler,
mercury and steam. Standard mercury vapour at 4.5 bar
ht = m × hhg1 ...(2.14) is supplied to the mercury turbine, from which it exhausts
at 0.04 bar. The mercury condenser generates saturated
Work done in the mercury cycle
steam at 15 bar which is expanded in a steam turbine to
= m . Whg ...(2.15)
0.04 bar.
Work done in the steam cycle
(i) Determine the overall efficiency of the cycle.
= 1 × Ws ...(2.16)
Total work done in the binary cycle is given by (ii) If 48000 kg/h of steam flows through the steam
Wt = m Whg + Ws ...(2.17) turbine, what is the flow through the mercury
turbine ?
POWER PLANT CYCLES 43
(iii) Assuming that all processes are reversible, what superheater located in the mercury boiler and if
is the useful work done in the binary vapour cycle the internal efficiencies of the mercury and steam
for the specified steam flow ? turbines are 0.84 and 0.88 respectively, calculate
(iv) If the steam leaving the mercury condenser is the overall efficiency of the cycle. The properties
superheated to a temperature of 300°C in a of standard mercury are given below :
= Hg cycle + steam cycle – Hg cycle × steam cycle (Q1)total = m (hl – hfk ) + 1 (h1 – h1)
= 0.31 + 0.318 – 0.31 × 0.318
[At 15 bar, 300°C :
= 0.5294 or 52.94%
Hence overall efficiency of the binary cycle hg = 3037.6 kJ/kg, sg = 6.918 kJ/kg K]
= 52.94%. (Ans.) = 11.06 × 326 + (3037.6 – 2789.9)
p
T4 T1
=1– ...(i)
T3 T2
3
v1
Let compression ratio, rc (= r) =
v2
Ad
iab v4
ati and expansion ratio, re (= r) =
c v3
2 (These two ratios are same in this cycle)
4
T2 Fv I 1
Adi
aba
tic
As
T1
= GH v JK
1
2
1
1
Then, T2 = T1 . (r )
Fv I
Clearance volume
1
T3
GH v JK
v 4
Similarly, =
Swept volume T4 3
1
Total volume or T3 = T4 . (r )
Inserting the values of T2 and T3 in equation (i), we
get:
T4 T1
otto = 1 – 1
T4 . (r ) T1 . (r ) 1
(a) p-v diagram T4 T1
=1– 1
r (T4 T1 )
T
1
=1– ...(2.25)
(r ) 1
This expression is known as the air standard
3
efficiency of the Otto cycle.
t.
It is clear from the above expression that efficiency
o ns increases with the increase in the value of r, which means
v =C we can have maximum efficiency by increasing r to a
2 4 considerable extent, but due to practical difficulties its value
is limited to about 8.
st. The net work done per kg in the Otto cycle can
Con
1 v= also be expressed in terms of pv. If p is expressed in bar
i.e., 105 N/m2, then work done
s FG p v p v
3 3 4 4 p2v2 p1v1 IJ × 10
(b) T-s diagram
W=
H 1
1 K 2 kJ
...(2.26)
Fig. 2.28. Otto cycle. p3 p2
Also, = r =
Consider 1 kg of air (working substance) : p4 p1
Heat supplied at constant volume = cv(T3 – T2). p3 p4
Heat rejected at constant volume = cv (T4 – T1). = = rp
p2 p1
But, work done = Heat supplied – Heat rejected where rp stands for pressure ratio.
= cv (T3 – T2) – cv (T4 – T1) LM∵ v1 v4
r
OP
Efficiency =
Work done and v1 = rv2 = v4 = rv3
N v2 v3 Q
Heat supplied
1 LM F
pv pv I F IO
v JP
MN GH JK GH K PQ
c (T T2 ) cv (T4 T1 ) W= p4 r 3 3 v3 p1r 2 2
= v 3 1 p4 r p1r
2
cv (T3 T2 )
46 POWER PLANT ENGINEERING
Also, pm = N 1 Q p
Maximum temperature, T3 = 1950 + 273 = 2223 K.
(v1 v2 ) (i) Compression ratio, r :
p1v1 For adiabatic compression 1–2,
[(r 1 1) (rp 1)]
1
=
Fv I
p2
(v1 v2 ) p1v1 = p2v2 or GH v JK
1
2
=
p1
p1v1
[(r 1 1) (rp 1)] p2
1 But, = 15 ...(given)
= p1
v
v1 1
r
(r ) = 15
LM∵ r
v1 OP
p1v1
[(r 1 1) (rp 1)]
N v2 Q
1 or (r)1.4 = 15
=
r1FG IJ 1
v1
1 H K or r = (15)1.4 = (15)0.714 = 6.9
Hence compression ratio = 6.9. (Ans.)
p1r[(r 1 1) (rp 1)]
i.e., = . ...(2.27)
( 1)(r 1) p (bar)
1 1
or, = 0.4 or (r)0.5 = = 2.5
0.5
(r ) 0.4 V(m )
3
VC VS
or, r = 6.25
Total volume
Hence, compression ratio = 6.25. (Ans.)
POWER PLANT CYCLES 47
T1
= 1 GH JK
v2
= (r )
1
= 210 kJ
Number of working cycles/min.
= (6.9)1.4 – 1 = (6.9)0.4 = 2.16 = 210.
or T2 = T1 × 2.16 = 311 × 2.16 (i) Pressures, temperatures and volumes at
= 671.7 K or 398.7°C salient points :
For adiabatic expansion process 3-4: For adiabatic compression 1–2:
T3 v F I 1 p1V1 = p2V2
T4
= 4
v3
GH JK = (r )
1
p (bar)
= (6.9)0.4 = 2.16
T3 2223 3
or T4 = = = 1029 K or 756°C
2.16 2.16
Heat supplied per kg of air
= cv(T3 – T2) = 0.717(2223 – 671.7)
LMc R 0.287 OP Adiabatics
MM 0.717 PP
v
1 1.4 – 1 11
N kJ/ kg K Q 2
p2 FV I
FG 1 IJ 1.4 1
or
p1
= GH V JK
1
2
= (r )
=
H 5.5 K = 0.505
Fp I
1 T4 = 0.505 T3 = 0.505 × 1172
F 11I
1
r= G J = G J
1.4
H1K
2
or
Hp K 1
= (11)0.714 = 5.5 = 591.8 K. (Ans.)
V4 = V1 = 0.45 m3. (Ans.)
T2 FV I
= G J 1
1
= (r )
1 (ii) Percentage clearance :
Also,
T1 HV K 2 Percentage clearance
1.4 1 Vc V2
= ( 5.5 ) = 1.977 ~
1.98 = × 100
Vs V1 V2
T2 = T1 × 1.98 = 303 × 1.98
0.081
= 600 K. (Ans.) = × 100
0.45 0.081
Applying gas laws to points 1 and 2, we get
= 21.95%. (Ans.)
p1V1 p2V2
= (iii) Efficiency :
T1 T2
The heat rejected per cycle is given by:
T2 p 600 1 0.45 Qr = mcv(T4 – T1)
V2 = 1 ×V =
T1 p2 1
303 11 = 0.517 × 0.71 (591.8 – 303)
= 0.081 m3. (Ans.)
= 106 kJ
The heat supplied during the process 2–3 is given
by : The air-standard efficiency of the cycle is given by
Q Qr 210 106
Qs = m cv (T3 – T2) otto = s =
Qs 210
p1V1 1 105 0.45 = 0.495 or 49.5%. (Ans.)
where m= = = 0.517 kg
RT1 287 303
⎡ It can also be calculated as follows : ⎤
210 = 0.517 × 0.71 (T3 – 600) ⎢ ⎥
1 1 ⎥
⎢ otto = 1 – =1–
210 ⎢ (r ) 1 (5.5)1.4 1 ⎥
or, T3 = + 600 ⎢ ⎥
0.517 0.71 ⎢⎣ ⎥⎦
= 0.495 or 49.5%. (Ans.)
= 1172 K. (Ans.)
(iv) Mean effective pressure, pm :
For the constant volume process 2–3
The mean effective pressure is given by:
p3 p
= 2 W (work done) Q Qr
T3 T2 pm = s
Vs (swept volume) (V1 V2 )
T3 1172
p3 = × p2 = × 11
T2 600 ( 210 106) 103
=
= 21.48 bar. (Ans.) ( 0.45 0.081) 105
V3 = V2 = 0.081 m3. (Ans.)
= 2.818 bar. (Ans.)
For the adiabatic (or isentropic) process 3–4
(v) Power developed, P :
p3V3 = p4V4
Power developed, P = work done per second
F V I = p × FG 1IJ
= work done per cycle
p4 = p3 × GH V JK 3
4 H rK 3 × number of cycles per second
= (210 – 106) × (210/60)
= 21.48 × G
F 1 IJ 1.4
= 364 kW. (Ans.)
H 5.5 K
= 1.97 bar. (Ans.) 2.10. DIESEL CYCLE
T4 FV I 1
F 1I
= G J
1 This cycle was introduced by Dr. R. Diesel in 1897. It differs
Also,
T3
= GH V JK
3
H rK from Otto cycle, in, that heat is supplied at constant
4 pressure instead of at constant volume. Fig. 2.31 (a) and
POWER PLANT CYCLES 49
(b) shows the p-v and T-s diagrams of this cycle respectively. Consider 1 kg of air.
This cycle comprises of the following operations : Heat supplied at constant pressure = cp(T3 – T2)
(i) 1–2......Adiabatic compression. Heat rejected at constant volume = cv(T4 – T1)
(ii) 2–3......Addition of heat at constant pressure. Work done = Heat supplied – Heat rejected
(iii) 3–4......Adiabatic expansion. = cv(T3 – T2) – cv(T4 – T1)
(iv) 4–1......Rejection of heat at constant volume.
Work done
Point 1 represents that the cylinder is full of air. Air standard =
Heat supplied
Let p1, V1 and T1 be the corresponding pressure, volume
and absolute temperature. The piston then compresses the c p (T3 T2 ) cv (T4 T1 )
=
air adiabatically (i.e. pV = constant) till the values become c p (T3 T2 )
p2, V2 and T2 respectively (at the end of the stroke) at (T4 T1 )
point 2. Heat is then added from a hot body at a constant =1– ...(i)
(T3 T2 )
pressure. During this addition of heat let volume
increases from V2 to V3 and temperature T2 to T3, LM∵ c p
OP
corresponding to point 3. This point (3) is called the point N c v Q
of cut-off. The air then expands adiabatically to the Let compression ratio,
conditions p4, V4 and T4 respectively corresponding to point v
r = 1 and cut-off ratio,
4. Finally, the air rejects the heat to the cold body at v2
constant volume till the point 1 where it returns to its v3 Volume at cut-off
original state. = i.e.,
v2 Clearance volume
p Now, during adiabatic compression 1–2,
T2 Fv I 1
2 3
T1
= GH v JK
1
2
(r ) 1
1
or, T2 = T1 . ( r )
During constant pressure process 2–3,
T3 v
Ad = 3 =
ia
ba T2 v2
Ad tic
1
ia
ba or, T3 = . T2 = . T1 . ( r )
tic During adiabatic expansion 3–4,
4
T3 Fv I 1
FG r IJ 1
1 T4
= GH v JK
4
3
=
H K
v F∵ v4 v1 v1 v2 r I
T GH
v3 v3 v2 v3
JK
T3 . T1 (r ) 1
T4 = T1 .
3
FG r IJ 1
FG r IJ 1
n st. H K H K
co 4 By inserting values of T2, T3 and T4 in equation (i),
p=
we get:
2
st. (T1 . T1 )
on =1–
v = c ( . T1 . ( r ) 1 T1 . ( r ) 1 )
1 ( 1)
=1–
(r ) 1 ( 1)
s
=1–
1 LM 1 OP
...(2.28)
Fig. 2.31
( r ) 1 MN 1 PQ
50 POWER PLANT ENGINEERING
v2 [ p2 ( 1) ( 1) p2 p4 r ( p2 p1r)]
= 1
1
(∵ p2 = p3) v
LM FG p4 IJ FG pr IJ OP
=
v2 p2 ( 1) ( 1) p2
MN H p2 K H
r p2 1 1
p2 K PQ T
1
1
p1v1r [( 1)( 1) r 1 (1 r 1 )]
=
1 p=C 4
3
p v r 1 [ ( 1) r1 ( 1)]
= 11 ...(2.29)
( 1) C
v=
Mean effective pressure is given by: 2
5
p1v1r 1 [ ( 1) r1 ( 1)]
pm =
FG r 1 IJ
( 1)v1
H r K
p1r [ ( 1) r1 ( 1)] 1
s
= . ...(2.30)
( 1)(r 1)
Fig. 2.32. Diesel cycle.
2.11. DUAL COMBUSTION CYCLE Consider 1 kg of air.
This cycle (also called the limited pressure cycle or mixed Total heat supplied
cycle) is a combination of Otto and Diesel cycles, in a way, = Heat supplied during the operation 2–3
that heat is added partly at constant volume and partly at
constant pressure ; the advantage of which is that more + Heat supplied during the operation 3–4
time is available to fuel (which is injected into the engine = cv(T3 – T2) + cp(T4 – T3)
cylinder before the end of compression stroke) for Heat rejected during operation 5–1 = cv(T5 – T1)
combustion. Because of laging characteristics of fuel this
cycle is invariably used for diesel and hot spot ignition Work done = Heat supplied – Heat rejected
engines. = cv(T3 – T2) + cp(T4 – T3) – cv(T5 – T1)
The dual combustion cycle (Fig. 2.32) consists of the Work done
=
following operations : Heat supplied
(i) 1–2. Adiabatic compression.
cv (T3 T2 ) c p (T4 T3 ) cv (T5 T1 )
(ii) 2–3. Addition of heat at constant volume. =
(iii) 3–4. Addition of heat at constant pressure. cv (T3 T2 ) c p (T4 T3 )
(iv) 4–5. Adiabatic expansion. cv (T5 T1 )
(v) 5–1. Rejection of heat at constant volume. =1–
cv (T3 T2 ) c p (T4 T3 )
POWER PLANT CYCLES 51
=1–
cv (T5 T1 )
...(i) 1
1 FG IJ
(T3 T2 ) (T4 T3 ) (r ) 1 H K
FG∵ cp IJ = 1
1FG IJ
H
cv K 1
H K
( 1)
v1 1 ( . 1)
Compression ratio, r = i.e., = 1 .
v2 (r ) 1 [( 1) ( 1)]
During adiabatic compression process 1–2, ...(2.31)
Work done is given by,
T2 Fv I 1
T1
= GH v JK
1
2
(r ) 1
...(ii) p v p5v5
W = p3(v4 – v3) + 4 4
1
p v p1v1
2 2
1
During constant volume heating process, ( p3v3 p5rv3 ) ( p2v3 p1rv3 )
= p3v3( – 1) +
p3 p 1
= 2
T3 T2 FG p5 IJ p
r p2v3 1 1 r
FG IJ
or,
T3
=
p3
= , =
p3v3 ( 1)( 1) p4v3
H p4 K p2 H K
T2 p2 1
where is known as pressure or explosion ratio.
p3 vF I FG IJ
or,
T
T2 = 3 ...(iii)
Also,
p4
4GH JK H r K
v3
During adiabatic expansion process, p2 Fv I
G J r
1
Fv I 1
FrI 1
and
p1 Hv K
2
GH v JK = G J
T4 5
T5
=
4 H K ...(iv) also, p3 = p4, v2 = v3, v5 = v1
F∵v5 v1 v1 v2 v1 v3 r I v3[ p3 ( 1) ( 1) p3 ( r1 )
GG
v4 v4 v2 v4 v2 v4
,
JJ p2 (1 r1 )]
H being the cut-off ratio K W=
( 1)
During constant pressure heating process, p2v2 [ ( 1) ( 1) ( 1 ) (1 r 1 )]
=
v3 v4 ( 1)
T3
= T
4 p1 (r) v1/ [ ( 1) ( 1) r 1 ( 1)]
=
v4 1
T4 = T3 = T3 ...(v)
v3 p1v1r 1[ ( 1) ( 1) r 1 ( 1)]
=
Putting the value of T4 in the equation (iv), we get: 1
T3 FG r IJ 1
FG IJ 1
Mean effective pressure,
...(2.32)
T5 = H K or T5 = . T3
H rK W W
Putting the value of T2 in equation (ii), we get:
pm =
v1 v2
r 1 FG IJ
T3
v1
r H K
p1v1 [r1 ( 1) ( 1) r1 ( 1)]
= (r ) 1
T1 =
r 1 FG IJ
T1 =
T3
.
1
( 1) v1
r H K
( r ) 1 p1 (r ) [ ( 1) ( 1) r1 ( 1)]
Now inserting the values of T1, T2, T4 and T5 in =
( 1)(r 1)
equation (i), we get: ...(2.33)
LM . T F I T . 1 OP 1
M GH r JK PQ
3
DIESEL CYCLE
N
3 1
(r )
= 1
LMFT T I (T T )OP Example 2.18. A diesel engine has a compression ratio of
NGH JK
3 15 and heat addition at constant pressure takes place at
3
Q 3 3
6% of stroke. Find the air standard efficiency of the engine.
Take for air as 1.4.
52 POWER PLANT ENGINEERING
But V3 – V2 =
100 s
V (Vs = stroke volume) 1.4 (12.04)1.4 1 MN 1.55 1 PQ
= 0.06 (V1 – V2) = 0.06 (15 V2 – V2) = 1 – 0.264 × 1.54
= 0.84 V2 or V3 = 1.84 V2 = 0.593 or 59.3%. (Ans.)
Example 2.20. Calculate the percentage loss in the ideal
V3 1.84 V2
= = 1.84 efficiency of a diesel engine with compression ratio 14 if the
V2 V2 fuel cut-off is delayed from 5% to 8%.
Putting the value in eqn. (i), we get:
Solution. Let the clearance volume be unity.
diesel = 1 –
1 LM (1.84) 1 OP
1.4
Then, compression ratio,
1.4 (15)1.4 1 MN 1.84 1 PQ r = 14
= 1 – 0.2417 × 1.605 Now, when the fuel is cut-off at 5%, we have
= 0.612 or 61.2%. (Ans.) 1 5 1
= or = 0.05
Example 2.19. The stroke and cylinder diameter of a r 1 100 14 1
compression ignition engine are 250 mm and 150 mm or – 1 = 13 × 0.05 = 0.65
respectively. If the clearance volume is 0.0004 m3 and fuel = 1.65
injection takes place at constant pressure for 5% of the stroke
determine the efficiency of the engine. Assume the engine diesel = 1 –
1 LM 1 OP
When the fuel is cut-off at 8%, we have: (i) Pressures and temperatures at all salient points.
1 8 1 8 (ii) Theoretical air standard efficiency.
= or = 0.08
r 1 100 14 1 100 (iii) Mean effective pressure.
= 1 + 1.04 = 2.04 (iv) Power of the engine if the working cycles per
diesel = 1 –
1 LM 1 OP
minute are 380.
Assume that compression ratio is 15 and working
(r ) 1 MN 1 PQ fluid is air.
= 1
1 LM (2.04) 1 OP
1.4 Consider all conditions to be ideal.
p1 = 1 bar Adiabatics
Refer to Fig. 2.31.
The mean effective pressure is given by:
4
p r [ ( 1) r1 ( 1)]
pm = 1
( 1)(r 1)
1 1 (27°C)
1 (12.5)1.4 [1.4 ( 1) (12.5)1 1.4 (1.4 1)]
7.5 = 3
(1.4 1)(12.5 1) v(m )
Vc Vs
34.33[1.4 1.4 0.3641.4 0.364 ]
7.5 =
4.6
7.5 = 7.46 (1.4 – 1.036 – 0.364 1.4) Fig. 2.34
1.005 = 1.4 – 1.036 – 0.364 1.4 (i) Pressures and temperatures at salient
or, 2.04 = 1.4 – 0.364 1.4 points :
or, 0.346 1.4 – 1.4 + 2.04 = 0 Now, stroke volume,
Solving by trial and error method, we get: Vs = /4 D2L = /4 × 0.22 × 0.3
= 2.24 = 0.00942 m3
1 Vs LM∵ Vc
Vs OP
percentage cut-off =
r 1
× 100 V1 = Vs + Vc = Vs +
r 1 N r 1 Q
2.24 1 FG 1 IJ r
=
12.5 1
× 100 = 10.78%. (Ans.) H
= Vs 1
r 1 K
r 1
× Vs
15 15
+Example 2.22. An engine with 200 mm cylinder diameter i.e., V1 = Vs × 0.00942
15 1 14
and 300 mm stroke works on theoretical Diesel cycle. The
initial pressure and temperature of air used are 1 bar and = 0.0101 m3. (Ans.)
27°C. The cut-off is 8% of the stroke. Determine : Mass of the air in the cylinder can be calculated by
using the gas equation,
54 POWER PLANT ENGINEERING
p1V1 = mRT1
T4 V3 F I 1
FG 1 IJ 1.4 1
p1V1 1 10 0.0101
m=
5 Also,
T3
=
V4
GH JK
H 7.07 K = 0.457
RT1 287 300 T4 = T3 × 0.457 = 1878.3 × 0.457
= 0.0117 kg/cycle
= 858.38 K. (Ans.)
For the adiabatic (or isentropic) process 1–2,
V4 = V1 = 0.0101 m3. (Ans.)
p2 V F I
p1V1 = p2V2 or
p1
1
V2
GH JK (r )
(ii) Theoretical air standard efficiency :
LM 1 OP
1
diesel = 1 –
p2 = p1 . (r ) = 1 ×
= 44.31 bar. (Ans.)
(15)1.4 (r ) 1 MN 1 PQ
FV I 1
= 1
1 LM (2.12) 1 OP
1.4
T
Also, 2 =
T1
GH V JK
1
2
= (r ) 1 (15)1.4 1 = 2.954 1.4 (15)1.4 1 MN 2.12 1 PQ
T2 = T1 × 2.954 = 300 × 2.954 = 1 – 0.2418 × 1.663
= 0.598 or 59.8%. (Ans.)
= 886.2 K. (Ans.)
(iii) Mean effective pressure, pm :
Vs 0.00942 Mean effective pressure of Diesel cycle is given by:
V2 = Vc =
r 1 15 1
= 0.0006728 m3. (Ans.) p1 (r ) [ ( 1) r1 ( 1)
pm =
p2 = p3 = 44.31 bar. (Ans.) ( 1)(r 1)
1 1 (15)1.4[1.4 ( 2.12 1) (15)1 1.4 ( 2.121.4 1)]
% Cut-off ratio = =
r 1 (1.4 1)(15 1)
8 1 44.31[1.568 0.338 1.863 ]
= =
100 15 1 0.4 14
i.e., = 0.08 × 14 + 1 = 2.12 = 7.424 bar. (Ans.)
V3 = V2 = 2.12 × 0.0006728 (iv) Power of the engine, P :
= 0.001426 m3. (Ans.) Work done per cycle
LMV3 can also be calculated as follows : OP 7.424 105 0.00942
MMV
3 0.08V V 0.08 0.00942 0.0006728 P
s c
PQ
= pmVs =
103
= 6.99 kJ/cycle
r
MM
V3 V2 V3 V2 V3
PP Clearance volume, Vc = V3 = V2 = 0.00035 m3
MM
, (∵ V4 V1)
PP Maximum pressure,
Initial temperature,
p3 = p4 = 65 bar
T1 = 80 + 273 = 353 K
15 MM
7.07 PP Initial pressure, p1 = 0.9 bar
2.12 N Q
POWER PLANT CYCLES 55
p (bar) Cut-off-ratio,
5
V V3
V4 100 s 0.05 V3 Vc
3 4
=
65 V3 V3 Vc
0.05 0.0053 0.00035
=
0.00035
2 Ad
iab = 1.757 say 1.76
ati
c Also during the compression operation 1–2,
Adia p1V1 = p2V2
bati
c 5
p2 FV I
0.9 1 (80°C)
or,
p1
= GH V JK
1
2
= (16.15)1.4 = 49.14
1 LM . 1 OP
L 3.243 1 OP
= 7 – 0.328 M
dual = 1 – ...(i)
(r ) 1 MN ( 1) ( 1) PQ N 0.47 1.564 Q
Compression ratio,
= 0.6383 or 63.83%. (Ans.)
V V Vc 0.0053 0.00035
r= 1 s
V2 Vc 0.00035 2.12. GAS TURBINE CYCLES
= 16.14
[∵ V2 = V3 = Vc = clearance volume] Refer to articles 5.11 and 5.12.
HIGHLIGHTS
T1 T2 [(h1 h2 ) (h3 h4 )] Wp
1. Carnot cycle efficiency = . thermal =
T1 [(h1 hf4 ) (h3 h2 )] Wp
2. Rankine cycle is the theoretical cycle on which steam
Pump work Wp is usually small and neglected.
prime movers work.
h1 h2 1
Rankine efficiency = . 6. Otto = 1 – .
h1 hf4 (r ) 1
THEORETICAL QUESTIONS
1. Describe the different operations of Rankine-cycle. Derive 2. How does a modified Rankine cycle differ from a Rankine
also the expression for its efficiency. cycle ? Write also the expression of modified Rankine
efficiency.
56 POWER PLANT ENGINEERING
3. State the methods of increasing the thermal efficiency of 6. Explain with a neat diagram the working of a Binary
a Rankine cycle. vapour cycle.
4. Explain with the help of neat diagrams a ‘Regenerative 7. Derive expressions for efficiencies of the following :
Cycle’. Derive also an expression for its thermal efficiency. (i) Diesel cycle (ii) Dual combustion cycle
5. State the advantages of regenerative cycle over simple (iii) Open cycle (constant pressure) gas turbine.
Rankine cycle.
UNSOLVED EXAMPLES
1. A simple Rankine cycle works between pressure of 30 bar 400°C. Steam is bled at 10 bar in regenerative heating.
and 0.04 bar, the initial condition of steam being dry The exit pressure is 0.8 bar. Neglecting pump work
saturated, calculate the cycle efficiency, work ratio and determine the efficiency of the cycle. [Ans. 0.296]
specific steam consumption. 7. A turbine with one bleeding for regenerative heating
[Ans. 35%, 0.997, 3.84 kg/kWh] of feed water is admitted with steam having enthalpy
2. A steam power plant works between 40 bar and 0.05 bar. of 3200 kJ/kg and the exhausted steam has an enthalpy of
If the steam supplied is dry saturated and the cycle of 2200 kJ/kg. The ideal regenerative feed water heater is
operation is Rankine, find : fed with 11350 kg/h of bled steam at 3.5 bar (whose
enthalpy is 2600 kJ/h). The feed water (condensate from
(i) Cycle efficiency.
the condenser) with an enthalpy of 134 kJ/kg is pumped
(ii) Specific steam consumption. to the heater. It leaves the heater dry saturated at 3.5
[Ans. (i) 35.5%, (ii) 3.8 kg/kWh] bar. Determine the power developed by the turbine.
3. Compare the Rankine efficiency of a high pressure plant [Ans. 16015 kW]
operating from 80 bar and 400°C and a low pressure plant 8. A binary-vapour cycle operates on mercury and steam.
operating from 40 bar 400°C, if the condenser pressure in Saturated mercury vapour at 4.5 bar is supplied to the
both cases is 0.07 bar. [Ans. 0.391 and 0.357] mercury turbine, from which it exhausts at 0.04 bar. The
4. A steam power plant working on Rankine cycle has the mercury condenser generates saturated steam at 15 bar
range of operation from 40 bar dry saturated to 0.05 bar. which is expanded in a steam turbine to 0.04 bar.
Determine : (i) Find the overall efficiency of the cycle.
(i) The cycle efficiency (ii) Work ratio (ii) If 50000 kg/h of steam flows through the steam
(iii) Specific fuel consumption. turbine, what is the flow through the mercury
turbine ?
[Ans. (i) 35.64%, (ii) 0.9957, (iii) 3.8 kg/kWh]
(iii) Assuming that all processess are reversible, what is
5. In a Rankine cycle, the steam at inlet to turbine is
the useful work done in the binary vapour cycle for
saturated at a pressure of 30 bar and the exhaust pressure
the specified steam flow ?
is 0.25 bar. Determine :
(iv) If the steam leaving the mercury condenser is super-
(i) The pump work (ii) Turbine work heated to a temperature of 300°C in a superheater
(iii) Rankine efficiency (iv) Condenser heat flow located in the mercury boiler, and if the internal effi-
(v) Dryness at the end of expansion. ciencies of the mercury and steam turbines are 0.85
Assume flow rate of 10 kg/s. and 0.87 respectively, calculate the overall efficiency
of the cycle. The properties of saturated mercury are
[Ans. (i) 30 kW, (ii) 7410 kW, (iii) 29.2%,
as follows :
(iv) 17900 kW, (v) 0.763]
6. In a regenerative cycle the inlet conditions are 40 bar and
p (bar) t (C) hf hg sf sg vf vg
(kJ/kg) (kJ/kg K) (m3/kg)
[Ans. (i) 52.94%, (ii) 59.35 × 104 kg/h, (iii) 28.49 MW, (iv) 46.2%]
9. The efficiency of an Otto cycle is 50% and is 1.5. What (iii) Mean effective pressure
is the compression ratio ? [Ans. 4] (iv) Ideal power developed by the engine if the engine
10. An engine working on Otto cycle has a volume of 0.5 m3, runs at 400 r.p.m. so that there are 200 complete
pressure 1 bar and temperature 27°C at the cycles per minutes.
commencement of compression stroke. At the end of [Ans. (i) 23.76% ; (ii) 47.2% ; (iii) 2.37 bar ; (iv) 321 kW]
compression stroke, the pressure is 10 bar. Heat added 11. The compression ratio in an air-standard Otto cycle is 8.
during the constant volume process is 200 kJ. Determine: At the beginning of compression process, the pressure is
(i) Percentage clearance (ii) Air standard efficiency
POWER PLANT CYCLES 57
1 bar and the temperature is 300 K. The heat transfer to is limited to 70 bar and heat supplied is limited to
the air per cycle is 1900 kJ/kg of air. Calculate : 675 kJ/kg of air. Find the thermal efficiency of the cycle.
(i) Thermal efficiency [Ans. 59.5%]
(ii) The mean effective pressure. 19. An air standard dual cycle has a compression ratio of 16,
[Ans. (i) 56.47% ; (ii) 14.24 bar] and compression begins at 1 bar, 50°C. The maximum
pressure is 70 bar. The heat transferred to air at constant
12. An engine 200 mm bore and 300 mm stroke works on
pressure is equal to that at constant volume. Determine :
Otto cycle. The clearance volume is 0.0016 m3. The initial
pressure and temperature are 1 bar and 60°C. If the (i) The cycle efficiency.
maximum pressure is limited to 24 bar, find : (ii) The mean effective pressure of the cycle.
(i) The air-standard efficiency of the cycle Take : cp = 1.005 kJ/kg K, cv = 0.718 kJ/kg K.
(ii) The mean effective pressure for the cycle. [Ans. (i) 66.5% ; (ii) 4.76 bar]
Assume ideal conditions. 20. In an air standard gas turbine engine, air at a temperature
[Ans. (i) 54.08% ; (ii) 1.972 bar] of 15°C and a pressure of 1.01 bar enters the compressor,
where it is compressed through a pressure ratio of 5. Air
13. Calculate the air standard efficiency of a four stroke Otto
enters the turbine at a temperature of 815°C and expands
cycle engine with the following data :
to original pressure of 1.01 bar. Determine the ratio of
Piston diameter (bore) = 137 mm ;
turbine work to compressor work and the thermal
Length of stroke = 130 mm ; efficiency when the engine operates on ideal Brayton cycle.
Clearance volume 0.00028 m3. Take : = 1.4, cp = 1.005 kJ/kg K. [Ans. 2.393 ; 37.03%]
Express clearance as a percentage of swept volume. 21. In an open cycle constant pressure gas turbine air enters
[Ans. 56.1% ; 14.6%] the compressor at 1 bar and 300 K. The pressure of air
14. In an ideal Diesel cycle, the temperatures at the after the compression is 4 bar. The isentropic efficiencies
beginning of compression, and the end of compression of compressor and turbine are 78% and 85% respectively.
and at the end of the heat addition are 97°C, 789°C and The air-fuel ratio is 80 : 1. Calculate the power developed
1839°C. Find the efficiency of the cycle. [Ans. 59.6%] and thermal efficiency of the cycle if the flow rate of air is
15. An air-standard Diesel cycle has a compression ratio of 2.5 kg/s.
18, and the heat transferred to the working fluid per cycle Take cp = 1.005 kJ/kg K and = 1.4 for air and cpg = 1.147
is 1800 kJ/kg. At the beginning of the compression stroke, kJ/kg K and = 1.33 for gases. R = 0.287 kJ/kg K. Calorific
the pressure is 1 bar and the temperature is 300 K. value of fuel = 42000 kJ/kg.
Calculate : (i) Thermal efficiency, (ii) The mean effective
pressure. [Ans. (i) 61% ; (ii) 13.58 bar] [Ans. 204.03 kW/kg of air ; 15.54%]
16. The following data belong to a Diesel cycle : 22. A gas turbine has a pressure ratio of 6/1 and a maximum
Compression ratio = 16 : 1 ; Heat added = 2500 kJ/kg ; cycle temperature of 600°C. The isentropic efficiencies of
Lowest pressure in the cycle = 1 bar ; Lowest temperature the compressor and turbine are 0.82 and 0.85 respectively.
in the cycle = 27°C. Determine : Calculate the power output in kilowatts of an electric
(i) Thermal efficiency of the cycle. generator geared to the turbine when the air enters the
compressor at 15°C at the rate of 15 kg/s.
(ii) Mean effective pressure.
Take : cp = 1.005 kJ/kg K and = 1.4 for the compression
[Ans. (i) 45% ; (ii) 16.8 bar]
process, and take cp = 1.11 kJ/kg K and = 1.333 for the
17. The compression ratio of an air-standard Dual cycle is
expansion process. [Ans. 920 kW]
12 and the maximum pressure in the cycle is limited to
70 bar. The pressure and temperature of cycle at the 23. The gas turbine has an overall pressure ratio of 5 : 1 and
beginning of compression process are 1 bar and 300 K. a maximum cycle temperature of 550°C. The turbine
Calculate : (i) Thermal efficiency, (ii) Mean effective drives the compressor and an electric generator, the
pressure. mechanical efficiency of the drive being 97%. The ambient
temperature is 20°C and the isentropic efficiencies of the
Assume : Cylinder bore = 250 mm, stroke length
compressor and turbine are 0.8 and 0.83 respectively.
= 300 mm, cp = 1.005, cv = 0.718 and = 1.4.
Calculate the power output in kilowatts for an air flow of
[Ans. (i) 61.92% ; (ii) 9.847 bar] 15 kg/s. Calculate also the thermal efficiency and the work
18. The compression ratio of a Dual cycle is 10. The ratio.
temperature and pressure at the beginning of the cycle Neglect changes is kinetic energy, and the loss of pressure
are 1 bar and 27°C. The maximum pressure of the cycle in combustion chamber. [Ans. 655 kW ; 12% ; 0.168]
Steam Power Plant 3
3.1. Introduction. 3.2. Classification of steam power plants. 3.3. Layout of a modern steam power plant. 3.4. Essential
requirements of steam power station design. 3.5. Selection of site for steam power station. 3.6. Capacity of steam
power plant. 3.7. Choice of steam conditions. 3.8. Fuel handling—Introduction—Requirements of good coal handling
plant—Coal handling systems—Coal handling—Layout of a fuel handling equipment. 3.9. Combustion equipment for steam
boilers—General aspects—Combustion equipment for solid fuels—selection considerations—Burning of coal—Burners.
3.10. Fluidised bed combustion (FBC). 3.11. Ash handling—Ash handling equipment—Ash handling systems. 3.12. Dust
collection—Introduction—Removal of smoke—Removal of dust and dust collectors—Efficiency of dust collectors—Installation
of dust collectors—Uses of ash and dust—General layout of ash handling and dust collection system—Flyash—Its composition,
disposal and applications. 3.13. Chimney draught—Definition and classification of draught—Natural draught—Chimney
height and diameter—Condition for maximum discharge through a chimney—Efficiency of a chimney—Draught losses—
Artificial draught—Forced draught—Induced draught—Balanced draught—Advantages of mechanical draught—Steam jet
draught—Worked examples. 3.14. Boilers—Introduction—Classification of boilers—Comparison between ‘fire-tube and water-
tube’ boilers— Selection of a boiler—Essentials of a good steam boiler—Boiler terms—Fire tube boilers—Water tube boilers—
High pressure boilers. 3.15. Accessories—Feed pumps—Injector—Economiser—Air preheater—Superheater—Steam
separator. 3.16. Feed water heaters and evaporators—Feed water heaters—Miscellaneous heaters—Evaporators—Typical
utility cycle layout. 3.17. Performance of boilers—Evaporative capacity—Equivalent evaporation—Factor of evaporation—
Boiler efficiency—Heat looses in a boiler plant. 3.18. Steam nozzles—Introduction—Steam flow through nozzles—Discharge
through the nozzle and conditions for its maximum value—Nozzle efficiency—Supersaturated or metastable expansion of
steam in a nozzle. 3.19. Steam turbines—Introduction—Classification of steam turbines—Advantages of steam turbine over
the steam engines—Description of common types of turbines—Methods of reducing wheel or rotor speed—Difference between
impulse and reaction turbines—Impulse turbines—Reaction turbines—Turbine efficiencies—Types of power in steam turbine
practice—Energy losses in steam turbines—Steam turbine governing and control—Special forms of turbines. 3.20. Steam
condensers—Introduction—Vacuum—Organs of a steam condensing plant—Classification of condensers—Jet condensers—
Surface condensers—Reasons for inefficiency in surface condensers—Comparison between jet and surface condensers—
Selection of condenser—Sources of air in condensers—Effects of air leakage in condenser—Method for obtaining maximum
vacuum in condensers—Vacuum measurement—Vacuum efficiency—Condenser efficiency—Determination of mass of cooling
water—Heat transmission through walls of tubes of a surface condenser—Methods of cleaning condenser tubes. 3.21. Cooling
ponds and cooling towers—Introduction—River or sea—Cooling ponds—Spray ponds—Cooling towers—Dry cooling
towers— Maintenance of cooling towers. 3.22. Feed water treatment—Classification of impurities in water—Troubles caused
by the impurities in water—Methods of feed water treatment—pH value of water. 3.23. Piping system—Requirements of
steam piping system—Materials used for pipes—Insulation of steam piping—Steam pipe fittings—Pipe expansion bends.
3.24. Advantages and disadvantages of steam power plants. 3.25. Miscellaneous—Plant arrangement—Useful life of
steam power plant components—Steam power plant pumps—Cost of steam power plant—Comparison of various types of
power plants—Thermal power stations in India—Indian boilers act—Highlights—Theoretical Questions—Unsolved Examples—
Competitive Examinations Questions.
Mechanical Electrical
3.1. INTRODUCTION energy energy
Steam
A steam power plant converts the chemical energy of the Turbine Grid
system
fossil fuels (coal, oil, gas) into mechanical/electrical energy. Generator
This is achieved by raising the steam in the boilers, Waste
Boiler
expanding it through the turbines and coupling the turbines gases
Water
to the generators which convert mechanical energy to
electrical energy as shown in Fig. 3.1. Fuel
The following two purposes can be served by a steam non-condensing because a large quantity of steam (low
power plant : pressure) is required for different manufacturing
1. To produce electric power. operations.
2. To produce steam for industrial purposes besides In the condensing steam power plants the following
producing electric power. The steam may be used for advantages accrue :
varying purposes in the industries such as textiles, food
manufacture, paper mills, sugar mills and refineries etc. (i) The amount of energy extracted per kg of steam
is increased (a given size of the engine or turbine develops
3.2. CLASSIFICATION OF STEAM POWER more power).
PLANTS (ii) The steam which has been condensed into water
in the condenser, can be recirculated to the boilers with
The steam power plants may be classified as follows :
the help of pumps.
1. Central stations.
In non-condensing steam power plants a continuous
2. Industrial power stations or captive power stations.
supply of fresh feed water is required which becomes a
1. Central stations. The electrical energy available
problem at places where there is a shortage of pure water.
from these stations is meant for general sale to the
customers who wish to purchase it. Generally, these 3.3. LAYOUT OF A MODERN STEAM
stations are condensing type where the exhaust steam is
POWER PLANT
discharged into a condenser instead of into the atmosphere.
In the condenser the pressure is maintained below the Refer to Fig. 3.2. The layout of a modern steam power plant
atmospheric pressure and the exhaust steam is condensed. comprises of the following four circuits :
2. Industrial power stations or captive power- 1. Coal and ash circuit.
stations. This type of power station is run by a 2. Air and gas circuit.
manufacturing company for its own use and its output is 3. Feed water and steam flow circuit.
not available for general sale. Normally these plants are
4. Cooling water circuit.
Coal To chimney
storage
Flue gases
Circulating
water pump Cooling tower
River or canal
Coal and ash circuit. Coal arrives at the storage 6. Circulating water pump
yard and after necessary handling, passes on to the furnaces 7. Boiler feed pump
through the fuel feeding device. Ash resulting from 8. Wagon tippler 9. Crusher house
combustion of coal collects at the back of the boiler and is
10. Coal mill 11. Induced draught fans
removed to the ash storage yard through ash handling
equipment. 12. Ash precipitators 13. Boiler chimney
Air and gas circuit. Air is taken in from 14. Forced draught fans
atmosphere through the action of a forced or induced 15. Water treatment plant
draught fan and passes on to the furnace through the air 16. Control room
preheater, where it has been heated by the heat of flue gases 17. Switch yard.
which pass to the chimney via the preheater. The flue gases
after passing around boiler tubes and superheater tubes 3.4. ESSENTIAL REQUIREMENTS OF
in the furnace pass through a dust catching device or
precipitator, then through the economiser, and finally
STEAM POWER STATION DESIGN
through the air preheater before being exhausted to the The essential requirements of steam power station design
atmosphere. are :
Feed water and steam flow circuit. In the water 1. Reliability
and steam circuit condensate leaving the condenser is first 2. Minimum capital cost
heated in a closed feed water heater through extracted
3. Minimum operating and maintenance cost
steam from the lowest pressure extraction point of the
turbine. It then passes through the deaerator and a few 4. Capacity to meet peak load effectively
more water heaters before going into the boiler through 5. Minimum losses of energy in transmission
economiser. 6. Low cost of energy supplied to the consumers
In the boiler drum and tubes, water circulates due 7. Reserve capacity to meet future demands.
to the difference between the density of water in the lower The above essential requirements depend to a large
temperature and the higher temperature sections of the extent on the following :
boiler. Wet steam from the drum is further heated up in
(i) Simplicity of design
the superheater before being supplied to the prime mover.
After expanding in high pressure turbine steam is taken (ii) Subdivision of plant and apparatus
to the reheat boiler and brought to its original dryness or (iii) Use of automatic equipment
superheat before being passed on to the low pressure (iv) Extensibility.
turbine. From there it is exhausted through the condenser
into the hot well. The condensate is heated in the feed 3.5. SELECTION OF SITE FOR STEAM
heaters using the steam trapped (bled steam) from different POWER STATION
points of turbine.
A part of steam and water is lost while passing The following points should be taken into consideration
through different components and this is compensated by while selecting the site for a steam power station :
supplying additional feed water. This feed water should 1. Availability of raw material
be purified before hand, to avoid the scaling of the tubes of 2. Nature of land
the boiler. 3. Cost of land
Cooling water circuit. The cooling water supply 4. Availability of water
to the condenser helps in maintaining a low pressure in it.
5. Transport facilities
The water may be taken from a natural source such as
river, lake or sea or the same water may be cooled and 6. Ash disposal facilities
circulated over again. In the later case the cooling 7. Availability of labour
arrangement is made through spray pond or cooling tower. 8. Size of the plant
Components of a Modern Steam Power Plant. 9. Load centre
A modern steam power plant comprises of the following 10. Public problems
components : 11. Future extensions.
1. Boiler
1. Availability of raw material. Modern steam
(i) Superheater (ii) Reheater
power stations using coal or oil as fuel require huge
(iii) Economiser (iv) Air-heater quantity of it per annum. A thermal power plant of 400 MW
2. Steam turbine 3. Generator capacity requires 5000 to 6000 tonnes of coal per day.
4. Condenser 5. Cooling towers Therefore, it is necessary to locate the plant as far as
STEAM POWER PLANT 61
possible near the coalfields in order to save the In a power station of 400 MW capacity 10 hectares
transportation charges. Besides transportation charges, a area is required per year if the ash is dumped to a height
plant located away from the coalfields, cannot always of 6.5 metres.
depend on the coal deliveries in time (i) as there may be 7. Availability of labour. During construction of
failure of transportation system, (ii) there may be strike plant enough labour is required. The labour should be
etc. at the mines. For these reasons a considerable amount available at the proposed site at cheap rate.
of coal must be stored at the power stations, this results 8. Size of the plant. The expenses involved in
in : electric transmission from a small plant are relatively
(i) increased investment ; severe, owing to the impracticability of using high voltages,
(ii) increased space required at the site of the plant so that the electric transmission feature alone becomes
for the storage ; dominant in the location of the plant. It case of large plants,
(iii) losses in storage ; and the costs of transporting enormous quantities of coal and
water are considerably high ; therefore, the plant must be
(iv) additional staff requirement. located near the pit head provided the required water
If it is not possible to locate the plant near the quantity must be available as near as possible. The large
coalfields then the plant should be located as near the plants should be located close to the railroad offering
railway station as possible. Even if this is not possible then adequate services. The economic significance of the large
at least arrangement should be made for railway siding to plant with small one is much greater than the mere ratio
the power plant so that the coal wagons can be shunted of size.
from the station to the site of power plant. This applies to 9. Load centre. A power station must be located
plants using oil as fuel, as well. near the loads to which it is supplying power. However, a
2. Nature of land. The type of the land to be plant cannot be located near all loads. As such C.G. of the
selected should have good bearing capacity as it has to loads is determined with reference to two arbitrarily chosen
withstand the dead load of the plant and the forces axes, this C. G. is known as the load centre (see Fig. 3.3).
transmitted to the foundation due to the machine
operations. The minimum bearing capacity of the land 2.5 km
should be 1 MN/m2.
3. Cost of land. Considerable area is required for 60 kVA 5 kVA
the power stations. The cost of the land for that purpose
should be reasonable. The large plants in the heart of big 1.2 km
cities and near the load centre are not economical as the
cost of land is very high. 20 kVA
4. Availability of water. Steam power stations use x=?
water as the working fluid which is repeatedly evaporated Load centre
and condensed. Theoretically there should be no loss of 2.7 km
water, but in fact some make up water is required. Besides
this, considerable amount of water is required for 1 km 1.9 km
condensers. A large quantity of water is also required for y=?
disposing the ash if hydraulic system is used. It is, 6 kVA
therefore, necessary to locate the power plant near the
water source which will be able to supply the required 0.9 km
quantity of water throughout the year.
5. Transport facilities. Availability of proper
Fig. 3.3. Load centre.
transport facilities is another important consideration in
locating the thermal power station. It is always necessary The power plant should be located, as far as possible
to have a railway line available near the power station for near the load centre in order to minimize the cost of
bringing in heavy machinery for installation and for transmission lines and also the losses occurring in them.
bringing the fuel. 10. Public problems. In order to avoid the nuisance
6. Ash disposal facilities. The ash handling from smoke, fly ash and heat discharged from the power
problem is more serious than coal handling because it comes plant, it should be located far away from the towns.
out in hot condition and it is highly corrosive. Its effect on 11. Future extensions. The choice of the site
atmospheric pollution are more serious as the human
should allow for economical extensions consistent with the
health is concerned. Therefore, there must be sufficient
estimated growth of load.
space to dispose of large quantity of ash.
62 POWER PLANT ENGINEERING
12. Consent of town planning department must be several hours. It is normally 10–15 per cent less than the
sought in case urban area is selected for the purpose. maximum capacity of the unit.
20
3.8. FUEL HANDLING
18
16 3.8.1. Introduction
Increase in cost and h
8
means :
6 1. Transportation by sea or river,
4 2. Transportation by rail,
2 3. Transportation by ropeways,
0 4. Transportation by road, and
20 30 40 50 60 70 80
Average output (MW) 5. Transportation of coal by pipeline.
The pipeline coal transport system offers the
Fig. 3.6 following advantages :
Fig. 3.7 indicates that steam consumption decreases 1. It provides simplicity in installation and
with increase in the capacity of the unit. increased safety in operation.
6.00 2. More economical than other modes of transport
when dealing with large volume of coal over long distances.
5.75 3. This system is continuous as it remains
Steam consumption (kg/kWh)
1. Coal delivery. From the supply points the coal (iii) Coal towers
may be delivered to power station though rail, road, river or (iv) Unloading bridges
sea. (v) Self unloading boats.
— Plants situated near the river or sea may make 3. Preparation. If the coal when delivered is in
use of navigation facilities. the form of lumps (not of proper size), the coal preparation
— Stations which cannot make use of navigation may be carried out by :
facilities may be supplied coal either by rail or (i) Breakers (ii) Crushers
trucks. Transportation of coal by trucks is usually
(iii) Sizers (iv) Dryers
used in case the mines are not far off or when
the necessary railway facilities are not available. (v) Magnetic separators.
In case rail transport is to be adopted, the 4. Transfer. ‘Transfer’ means the handling of coal
necessary siding for receiving the coal should be between the unloading point and the final storage point
brought as near the station as possible. from where it is discharged to the firing equipment. The
2. Unloading. The type of coal unloading equipment following equipment may be used for transfer of coal :
used in the plant depends upon the type of out-plant 1. Belt conveyors
handling mode as road, rail or ship. If coal is delivered by 2. Screw conveyors
trucks, there is no need of unloading device as the trucks
may dump the coal to the outdoor storage. Coal is easily 3. Vee bucket elevator and conveyor
handled if the lift trucks with scoop are used (see Fig. 3.10). 4. Pivoted bucket conveyor
5. Grab bucket conveyor
6. Flight conveyers (or scrapers)
7. Skip hoists
8. Mass flow conveyor
9. Chutes.
(i) Belt conveyor. Refer to Fig. 3.11. A belt conveyor
is very suitable means of transporting large quantities of
coal over large distances. It consists of an endless belt (made
of rubber, convas or balata) running over a pair of end drums
or pulleys and supported by a series of rollers (known as
idlers) provided at regular intervals. The return idlers which
support the empty belt are plain rollers and are spaced wide
apart. The initial cost of the system is not high. The
Fig. 3.10. Lift truck with scoop. inclination at which coal can be successfully elevated by belt
conveyor is about 20°. Average speed of the belt conveyor is
When the coal is transported by sea, the unloading 60 to 100 metres per minute. The load carrying capacity of
equipment normally used is given below : the belt may vary from 50 to 100 tonnes/hour and it can
(i) Portable conveyors easily be transferred through 400 metres. It is used in
(ii) Coal accelerators medium and large power plants.
Belt
Drive Tripper (if used) Belt loader
pulley
+ ++
+
Over-end Tripper Carriers
discharge discharge Idlers
6. The rate of coal transfer can be easily varied by transfer coal at considerable heights as involved in modern
just varying the belt speed. stations, the length of the conveyor becomes excessive.
7. Coal being transferred is protected. (ii) Screw conveyor. Refer to Fig. 3.12. It consists
of an endless helicoid screw fitted to a shaft. The driving
Disadvantages :
mechanism is connected to one end of the shaft and the
1. Not suitable for greater heights and short other end of the shaft is supported in an enclosed ball
distances. bearing. The screw while rotating in a trough/housing
2. As the maximum inclination at which coal can be transfers coal from one end to the other end. The following
transferred by this arrangement is limited, in order to particulars relate to this conveyor.
Coal in
Ball
bearing
Driving
mechanism
Scrapper
Roller Chain
Coal
Crusher
45°
Automatic
weigher
Conveyor
Boiler hoppers
necessary to receive the fuel and air, proportioned to each Depending on the type of combustion equipment,
other and to the boiler steam demand, mix, ignite, and boilers may be classified as follows :
perform any other special combustion duties, such as 1. Solid fuels fired :
distillation of volatile from coal prior to ignition. (a) Hand fired
— Fluid fuels are handled by burners ; solid lump (b) Stoker fired
fuels by stokers.
(i) Overfeed stokers
— In boiler plants hand firing on grates is
(ii) Underfeed strokers.
practically unheard of now-a-days in new plants,
although there are many small industrial plants (c) Pulverised fuel fired
still in service with hand firing. (i) Unit system
— The fuels are mainly bituminous coal, fuel oil (ii) Central system
and natural gas mentioned in order of (iii) Combination of (i) and (ii).
importance. All are composed of hydrocarbons,
2. Liquid fuel fired :
and coal has, as well, much fixed carbon and little
sulphur. To burn these fuels to the desired end (a) Injection system
products, CO2 and H2O, requires (i) air in (b) Evaporation system
sufficient proportions, (ii) a good mixing of the (c) Combination of (a) and (b).
fuel and air, (iii) a turbulence or relative motion
3. Gaseous fuel fired :
between fuel and air. The combustion equipment
must fulfil these requirements and, in addition, (a) Atmospheric pressure system
be capable of close regulation of rate of firing the (b) High pressure system.
fuel, for boilers which ordinarily operate on
3.9.2. Combustion Equipment for Solid Fuels—
variable load. Coal-firing equipment must also
have a means for holding and discharging the Selection Considerations
ash residue. While selecting combustion equipment for solid fuels the
following considerations should be taken into account :
The basic requirements of combustion
equipment : 1. Initial cost of the equipment.
1. Thorough mixing of fuel and air. 2. Sufficient combustion space and its ability to
withstand high flame temperature.
2. Optimum fuel-air ratios leading to most complete
combustion possible maintained over full load range. 3. Area of the grate (over which fuel burns).
3. Ready and accurate response of rate of fuel feed 4. Operating cost.
to load demand (usually as reflected in boiler steam 5. Minimum smoke nuisance.
pressure). 6. Flexibility of operation.
4. Continuous and reliable ignition of fuel. 7. Arrangements for thorough mixing of air with
5. Practical distillation of volatile components of fuel for efficient combustion.
coal.
3.9.3. Burning of Coal
6. Adequate control over point of formation and
accumulation of ash, when coal is the fuel. The two most commonly used methods for the burning of
coal are :
Natural gas is used as a boiler fuel in gas well
1. Stroker firing
regions where fuel is relatively cheap and coal sources
comparatively distant. The transportation of natural gas 2. Pulverised fuel firing.
over land to supply cities with domestic and industrial heat The selection of one of the above methods depends
has made the gas in the well more valuable and the gas- upon the following factors :
fired steam generator more difficult to justify in comparison (i) Characteristics of the coal available.
with coal, or fuel cost alone. Cleanliness and convenience (ii) Capacity of the boiler unit.
in use are other criteria of selection, but more decisive in (iii) Load fluctuations.
small plants in central power stations.
(iv) Station load factor.
Transportation costs add less to the delivery price
of oil than gas ; also fuel oil may be stored in tanks at a (v) Reliability and efficiency of the various types of
reasonable cost, whereas, gas cannot. Hence although fuel combustion equipment available.
oil is usually more costly than coal per kg of steam 3.9.3.1. Stoker firing
generated, many operators select fuel oil burners rather
than stokers because of the simplicity and cleanliness of A “stoker” is a power operated fuel feeding mechanism and
storing and transporting the fuel from storage to burner. grate.
70 POWER PLANT ENGINEERING
CO2 + O2 + N2 + H2O
Flame Secondary air
Grate
The fuel bed section receives fresh coal on top Fresh fuel undergoing distillation of its volatile
surface. The ignition plane lies between green coal and matter forms the top-most layer of the fuel bed. Heat for
incandescent coke. distillation and eventually ignition comes from the
The air (with its water vapour content from following four sources :
atmosphere) enters the bottom of the grate under pressure. (i) By conduction from the incandescent coke below.
In flowing through the grate opening the air is heated while (ii) From high temperature gases diffusing through
it cools the grate. The warm air then passes through a layer the surface of the bed.
of hot ashes and picks up the heat energy.
(iii) By radiation from flames and hot gases in the
The region immediately above the ashes contains a furnace.
mixture of incandescent coke and ash, coke content
(iv) From the hot furnace walls.
increasing in upward direction. As the air comes in contact
with incandescent coke, the oxygen reacts with carbon to The ignition zone lies directly below the raw fuel
form carbon dioxide. Water vapour entering with the air undergoing distillation.
reacts with coke to form CO2, CO and free H2. Upon further To burn the combustible gases, additional secondary
travel through the incandescent region some of the CO2 air must be fed into the furnace to supply the needed
reacts with coke to form CO. Hence no free O2 will be oxygen. The secondary air must be injected at considerable
present in the gases leaving the incandescent region. speed to create turbulence and to penetrate to all parts of
STEAM POWER PLANT 71
the area above the fuel bed. The combustible gases then The rate of burning with this stoker is 200 to
completely burn in the furnace. 300 kg per m2 per hour when forced draught is used.
Fuel, coke and ash in the fuel bed move in direction Advantages of chain grate stoker :
opposite to that of air and gases. Raw fuel continually drops
1. Simple in construction.
on the surface of the bed. The rising air feed cools the ash
until it finally rests in a plane immediately adjacent to the 2. Initial cost low.
grate. 3. Maintenance charges low.
Types of overfeed stokers 4. Self-cleaning stoker.
The “overfeed stokers” are used for large capacity 5. Gives high release rates per unit volume of the
boiler installation where the coal is burnt with pulverisation. furnace.
These stokers are mainly of following two types : 6. Heat release rates can be controlled just by
1. Travelling grate stoker controlling the speed of chain.
(a) Chain grate type (b) Bar grate type Disadvantages :
2. Spreader stoker. 1. Preheated air temperatures are limited to 180°C
1. Travelling grate stoker maximum.
These stokers may be chain grate type or bar grate 2. The clinker troubles are very common.
type. These two differ only in the details of grate 3. There is always some loss of coal in the form of
construction. fine particles through riddlings.
Fig. 3.19 shows a “Chain grate stoker”. 4. Ignition arches are required (to suit specific
A chain grate stoker consists of flexible endless chain furnace conditions).
which forms a support for the fuel bed. The chain travels 5. This cannot be used for high capacity boilers
over two sprocket wheels one at the front and one at the (200 tonnes/hr or more).
rear of furnace. The front sprocket is connected to a variable
speed drive mechanism. The speed of the stroker is 15 cm 2. Spreader stoker. Refer to Fig. 3.20.
to 50 cm per minute. — In this type of stoker the coal is not fed into
The coal bed thickness is shown for all times by an furnace by means of grate. The function of the
index plate. This can be regulated either by adjusting the grate is only to support a bed of ash and move it
opening of fuel grate or by the speed control of the stoker out of the furnace.
driving motor. — From the coal hopper, coal is fed into the path of
The air is admitted from the underside of the grate a rotor by means of a conveyer, and is thrown
which is divided into several compartments each connected into the furnace by the rotor and is burnt in
to an air duct. The grate should be saved from being suspension. The air for combustion is supplied
overheated. For this, coal should have sufficient ash content through the holes in the grate.
which will form a layer on the grate. — The secondary air (or overfire air) to create
Since there is practically no agitation of the fuel bed, turbulence and supply oxygen for thorough
non-coking coals are best suited for chain grate stokers. combustion of coal is supplied through nozzles
located directly above the ignition arch.
Over fire or
secondary Coal
air parts hopper
— Unburnt coal and ash are deposited on the grate 8. As the depth of coal bed on the grate is usually
which can be moved periodically to remove ash limited to 10 to 15 cm only, fluctuating loads can be easily
out of the furnace. met with.
— Spreader stokers can burn any type of coal. Disadvantages :
— This type of stoker can be used for boiler 1. It is difficult to operate spreader with varying
capacities from 70000 kg to 140000 kg of steam sizes of coal with varying moisture content.
per hour. The heat release rate of 10 × 106 kcal/ 2. Fly-ash is much more.
m2-hr is possible with stationary grate and of 3. No remedy for clinker troubles.
20 × 106 kcal/m2-hr is possible with travelling
4. There is a possibility of some fuel loss in the
grate.
cinders up the stack because of the thin fuel bed and
Advantages : suspension burning.
1. A wide variety of coal can be burnt. 2. Underfeed stokers
2. This stoker is simple to operate, easy to light up Principle of operation. Refer to Fig. 3.21 (a).
and bring into commission. — The underfeed principle is suitable for burning
3. The use of high temperature preheated air is the semi-bituminous and bituminous coals.
possible. — Air entering through the holes in the grate comes
4. Operation cost is considerably low. in contact with the raw coal (green coal). Then it
passes through the incandescent coke where
5. The clinking difficulties are reduced even with reactions similar to overfeed system take place.
coals which have high clinkering tendencies. The gases produced then pass through a layer
6. Volatile matter is easily burnt. of ash. The secondary air is supplied to burn the
7. Fire arches etc. are generally not required with combustible gases.
this type of stokers.
The underfeed stokers fall into two main groups, the single retort and multi-retort stokers.
CO2 + O2 + H2 + H2O
Ash
Incandescent VM + CO + CO2 + N2 + H2
coke (VM = Volatile matter)
Green
coal
Multi-retort underfeed stokers : vacated by the rain. On the inward stroke the
Refer to Fig. 3.21 (b). ram forces the coal into the retort.
— The stoker consists of a series of sloping parallel — The height and profile of the fuel bed is controlled
troughs formed by tuyere stacks. These troughs by secondary, or distributing rams. These rams
are called retorts. Under the coal hopper at the oscillate parallel to the retort axes, the length of
head end of the retorts, feeding rams reciprocate their stokes can be varied as needed. They slowly
back and forth. With the ram in the outer move the entire fuel bed down the length of the
position coal from the hopper falls into space stoker.
STEAM POWER PLANT 73
Inlet connection
damper load.
Ash
Forced 10. With the use of clinker grinder, more heat can
air duct be liberated out of fuel.
11. Substantial amount of coal always remains on
Fig. 3.21 (b) Multi-retort underfeed stokers.
the grate so that the boiler may remain in service in the
— At the rear of the stoker the partly burned fuel event of temporary breakdown of the coal supply system.
bed moves onto an extension grate arranged in 12. It can be used with all refractory furnaces
sections. These sections also oscillate parallel to because of non-exposure of stoker mechanism to the
the fuel-bed movement. The sharp slope of the furnace.
stoker aids in moving the fuel bed. Fuel-bed
movement keeps it slightly agitated to break up Disadvantages :
clinker formation. From extension grate the ash 1. High initial cost.
moves onto ash dump plate. Tilting the dump 2. Require large building space.
plate at long intervals deposits the ash in the
3. The clinker troubles are usually present.
ashpit below.
4. Low grade fuels with high ash content cannot be
— Primary air from the wind box underneath
burnt economically.
the stoker enters the fuel bed through holes in
the vertical sides of the tuyeres. The extension 3.9.3.2. Pulverised fuel firing
grate carries a much thinner fuel bed and so
In pulverised fuel firing system the coal is reduced to a
must have a lower air pressure under it. The air
fine powder with the help of grinding mill and then projected
entering from the main wind box into the
into the combustion chamber with the help of hot air current.
extension-grate wind box is regulated by a
The amount of air required (known as secondary air) to
controlling air damper.
complete the combustion is supplied separately to the
In this stoker the number of retorts may vary from combustion chamber. The resulting turbulence in the
2 to 20 with coal burning capacity ranging from 300 kg to combustion chamber helps for uniform mixing of fuel and
2000 kg per hour per retort. air and thorough combustion. The amount of air which is
Underfeed stokers are suitable for non-clinkering, used to carry the coal and to dry it before entering into the
high voltatile coals having caking properties and low ash combustion chamber is known as ‘Primary air’ and the
contents. amount of air which is supplied separately for completing
the combustion is known as ‘Secondary air’.
Advantages :
The efficiency of the pulverised fuel firing system
1. High thermal efficiency (as compared to chain mostly depends upon the size of the powder. The fineness
grate stokers). of the coal should be such as 70% of it would pass through
2. Combustion rate is considerably higher. a 200 mesh sieve and 90% through 50 mesh sieve.
74 POWER PLANT ENGINEERING
Fig. 3.22 shows elements of pulverised coal system. 4. The maintenance of furnace brickwork is costly.
5. Special equipment is needed to start this system.
6. The skilled operators are required.
Bunker 7. A separate coal preparation plant is necessary.
8. High furnace temperatures cause rapid
deterioration of the refractory surfaces of the furnace.
9. Nuisance is created by the emission of very fine
Secondary particles of grit and dust.
air duct
10. Fine regular grinding of fuel and proper
Primary air
Furnace
distribution to burners is usually difficult to achieve.
to coal
Pulverised Fuel Handling
Basically, pulverised fuel plants may be divided into
the following two systems :
Burner 1. Unit system
Feeder
2. Central system.
Unit system :
A unit system is shown in Fig. 3.23.
Fig. 3.22. Elements of pulverised coal system.
7. In a replacement of stokers, the old conveyor and 5. The large storage is protection against
bunker equipment may be used. interruption of fuel supply to the burners.
8. Coal which would require drying in order to 6. Less labour is required.
function satisfactorily in the central system may usually
7. Power consumption per tonne of coal handled is
be employed without drying in the unit system.
low.
Disadvantages : 8. Burners can be operated independent of the
1. Firing aisle is obstructed with pulverising operation of coal preparation plant.
equipment, unless the latter is relegated to a basement.
9. Fans handle only air, as such, there is no problem
2. The mills operate at variable load, a condition of excessive wear as in case of unit system, where air and
not especially conducive to best results.
coal both are handled by the fan.
3. With load factors in common practice, total mill
capacity must be higher than for the central system. Disadvantages :
4. Flexibility is less than central system. 1. Driers are usually necessary.
Central system : 2. Fire hazard of quantities of stored pulverised coal.
This system is illustrated in Fig. 3.24. 3. Central preparation may require a separate
building.
4. Additional cost and complexity of coal
Raw coal
bunker transportation system.
5. Power consumption of auxiliaries is high.
Cyclone
Central storage Pulveriser. Coal is pulverised in order to increase
bin of pulverised its surface exposure, thus promoting rapid combustion
coal without using large quantities of excess air. A pulveriser
Burner is the most important part of a pulverised coal system.
feeder
Pulverisers (sometimes called mills) are classified as
Burner follows:
Primary
Feeder Pulverising air fan 1. Attrition mills
mills (i) Ball and race mills.
Alternative flue (ii) Bowl mills
gas for coal drying 2. Impact mills
Fig. 3.24. Central system. (i) Ball mills
A central pulverising system employs a limited (ii) Hammer mills.
number of large capacity pulverisers at a central point to Pulverisers are driven by electric motors with the
prepare coal for all the burners. Driers, if required, are feeders either actuated by the main drive or by a small
conveniently installed at this point. From the pulverisers D.C. motor, depending upon the control used.
the coal is transported to a central storage bin where it is
deposited and its transporting air vented from the bin Ball and race mill. This a low speed unit in which
through a “cyclone”. This bin may contain from 12 to 24 grinding pressure is maintained by adjustable springs. The
hours supply of pulverised coal. From the bin the coal is coal passes between the two rotating elements again and
metered to the burners by motor-driven feeders of varied again until it has been pulverised to the desired degree of
design. Primary air, added at the feeders, floats the coal to fineness. Fig. 3.25 shows a ball and race mill. Mill, feeder
the burners. and fan require up to 14 kWh per tonne of coal pulverised.
Advantages : Bowl mill. The bowl mill grinds the coal between a
1. Offers good control of coal fineness. whirling bowl and rolls mounted on pivoted axes. Coal fed
2. The pulverising mill may work at constant load into the centre is thrown by centrifugal force against the
because of the storage capacity between it and the burners. sides of the bowl where it is pulverised between the sides
of the bowl and the grinding ring. The fine and intermediate
3. The boiler aisels are unobstructed.
sizes are picked up from the top by an air current and
4. More latitude in the arrangement and number carried into the separator above for classification. It
of burners is allowed to the designers. consumes about 5 kWh of electricity per tonne of coal.
76 POWER PLANT ENGINEERING
Fine discharge
Raw coal feed
Rotating
classifiers
Spring
Furnaces for low volatile coal are equipped with such 3. Tangential burners. These burners are set as
burners to give a long flame path for slower burning shown in Fig. 3.30. In this case four burners are located in
particles. the four corners of the furnace and are fired in such a way
that the four flames are tangential to an imaginary circle
Primary formed at the centre. The swirling action produces adequate
air and coal turbulence in the furnace to complete the combustion in a
short period and avoids the necessity of producing high
Tertiary turbulence at the burner itself.
air
Secondary
air
Hearth
Molten ash
Fig. 3.28. Long flame burner.
2. Turbulent burners. Refer to Fig. 3.29. It is also
called a short flame burner. These burners can fire
horizontally or at some inclinations by adjustment. The
fuel-air mixture and secondary hot air are arranged to pass
through the burner in such a way that there is good mixing
and the mixture is projected in highly turbulent form in
the furnace. Due to high turbulence created before entering Fig. 3.30. Plan of furnace with tangential firing.
the furnace, the mixture burns intensely and combustion
is completed in short distance. The tangential burners have the following
advantages :
Coal and
1. The parts of the burner are well-protected by
primary air
furnace wall tubes.
2. The operation of these burners is very simple.
3. High heat release with complete and effective
utilisation of furnace volume is possible.
4. The completeness of combustion is exceptionally
good and a maximum degree of turbulence exists
throughout the furnace.
5. Liquid, gaseous and pulverised fuels can be
readily burned either separately or in combination.
Furnace
4. Cyclone burners. Two main disadvantages
associated with pulverised coal firing are :
Secondary air
(i) High cost.
(ii) 70% of the ash escapes as fly-ash which requires
Fig. 3.29. Turbulent burner. expensive dust collectors in the flue gas path.
This burner gives high rate of combustion compared These disadvantages are offset by a cyclone burner.
with other types. This is generally preferred for high volatile In a cyclone burner coal is crushed to a maximum size of
coals. All modern plants use this type of burner. 6 mm and blows into a cylindrical cyclone furnace. The
78 POWER PLANT ENGINEERING
fuel is quickly consumed and liberated ash forms a molten capacity of the boiler. Depending upon the capacity of the
film flowing over the inner wall of the cylinder. Owing to burner the number of cyclone burners used may be one or
inclination of the furnace, the molten ash flows to an more. If the number of cyclone burners used is more than
appropriate disposal system. one, the diameter of each burner is less. These burners are
The description of a cyclone burner (developed by attached to the side of the furnace wall and have vents for
M/s Babcock and Wilcox) is given below : Refer to Fig. 3.31. primary air, crushed coal (6 mm diameter maximum size)
It consists of a horizontal cylindrical drum having a and secondary air. It is water-cooled. The horizontal axis
diameter varying from 2 to 4 metres depending upon the of the burner is slightly deflected towards the boiler.
Secondary
air
Primary air
and coal
Furnace
Hot
gases
Tertiary Cyclone
air cylinder Molten ash
The cyclone burner receives crushed coal carried in 8. Combustion rates can be controlled by
primary air (at 80 cm water pressure) at the left end. simultaneous manual adjustment of fuel feed and air flow
Tangential entry of the coal throws it to the surface of the and response in firing rate changes is comparable to that
cylindrical furnace. Secondary air enters the furnace of pulverised coal firing.
through tangential ports at the upper edge at high speed
and creates a strong and highly turbulent vortex. Extremely
3.9.4.2. Oil burners
high heat liberation rate and use of preheated air cause Principle of oil firing. The functions of an oil burner are
high temperatures to the tune of 2000°C in the cyclone. to mix the fuel and air in proper proportion and to prepare
The fuel supplied is quickly consumed and liberated ash the fuel for combustion. Figure 3.32 shows the principle of
forms a molten film flowing over the inner wall of the oil firing.
cylinder. Due to horizontal axis of the burner being tilted
the molten ash flows to an appropriate disposal system.
The cyclone furnace gives best results with low grade fuels.
Advantages :
1. High furnace temperatures are obtained. Fuel
Flames
2. Simplified coal existing equipments can be used Air
instead of costly pulverised mills.
3. The cyclone burners reduce the percentage of
excess air used.
4. It can burn poorer and cheaper grades of coal.
Fig. 3.32. Principle of oil burning.
5. As the swirling effect and consequently the
mixing of air and crushed coal is better, it provides for a Classification of oil burners. The oil burners may
higher furnace capacity and efficiency. be classified as :
6. Boiler efficiency is increased. 1. Vapourising oil burners :
7. The cost of milling in cyclone fire is less as the (a) Atmospheric pressure atomising burner
finer particles are not required in this case. (b) Rotating cup burner
STEAM POWER PLANT 79
(c) Recirculation burner capillary action. The fuel from the uppermost part of the
(d) Wick type burner wick is evaporated due to radiant heat from the flame and
2. Atomising fuel burners : the nearby heated surfaces. Air is admitted through holes
in the surrounding walls.
(a) Mechanical or oil pressure atomising burner
A wick burner is suitable for models or domestic
(b) Steam or high pressure air atomising burner
appliances.
(c) Low pressure air atomising burner.
2. Atomising fuel burners. Following are the
1. Vapourising oil burners. Following are the requirements of an automising fuel burner :
requirements of a vapourising/evaporation oil burner : (i) To automise the fuel into fine particles of equal
(i) To vapourise the fuel before ignition. size.
(ii) To mix the vapourised fuel thoroughly with (ii) To supply air in required quantity at proper
the air. places in the combustion chamber.
(iii) To minimise the soot formation. (iii) To give high combustion intensity.
(iv) To give high heat release by burning large (iv) To give high thermal efficiency.
quantity of oil per hour. (v) To operate without difficulty at varying loads.
(v) To allow for efficient combustion of fuel at (vi) To create necessary turbulence inside the
part load operation. combustion chamber for proper combustion of fuel.
(a) Atmospheric pressure atomising burner. (vii) To minimise soot formation and carbon deposit,
particularly on the burner nozzle.
This burner makes use of highly volatile liquid fuels such
as neptha, volatile gasoline etc. Here the fuel at low pressure (a) Mechanical atomising burners. A mechanical
is passed through a tube adjacent to the flame before being atomising oil burner consists of the following four principal
released through an orifice. While passing through the hot parts :
tube, most of the fuel is vapourised so that the fluid ejected (i) Atomiser (ii) Air register (iii) Diffuser (iv) Burner
from the orifice is more or less a vapour. The required throat opening.
quantity of primary air is supplied to burn the vapour (i) Atomiser. It breaks up the oil mechanically into
stream in a cylindrical tube. a fine uniform spray that will burn with minimum of excess
(b) Rotating cup burner. These burners are used air when projected into the furnace. The spray is produced
on low as well as medium capacity boilers. by using relatively high pressure to force oil at high velocity
In this type of burner, the fuel oil flows through a through small tangential passages of sprayer plate into a
tube in the hollow shaft of the burner and into the cup at chamber where it is rapidly rotated, centrifugal force in
the rotating oil causes it to break up into a thin layered,
the furnace end. An electric motor or an air turbine runs
mist like, hollow conical spray as it is released through the
the shaft and the cup at high speeds (3000 to 10000 r.p.m.).
orifice plate.
As a result of centrifugal force fuel is split into small
droplets. About 10 to 15 per cent of air is supplied as (ii) Air register. An air register is an integral part of
the oil-burner assembly. It consists of a number of
primary air. This air is supplied from a blower surrounding
overlapping vanes which deliver the air for combustion to
the cup. The shape of the flame is governed by the sharp
the furnace throat with the correct degree of spin.
edge of the cup and the position of air nozzle.
(iii) Diffuser. It is a shield in the form of a perforated
(c) Recirculating burner. The part of the
hollow metal cone mounted near the furnace end of the
combustion products may be recirculated in order to heat atomiser assembly. It stabilises the flame to prevent it from
up the incoming stream of fuel and air. Low ratio of the being blown away from the atomiser tip.
mass of recirculated combustion products to the mass of
(iv) Burner throat opening. It is circular and
unburnt fuel-air mixture results in less temperature rise
concentric with burner outlet. It is made of refractory. The
of the mixture, whereas, high ratio may extinguish the atomiser and diffuser assembly should be so positioned that
flame due to increased proportions of circulated products. the flame clears the throat opening sufficiently to avoid
An optimum ratio may be determined for different fuels striking. This burner has an insulated front and thus is
experimentally. designed to operate with preheated air.
In recirculation burner (utilising the above principle) (b) Steam atomising burners. Of various methods
circulation system is separated from the combustion by a of oil atomisation, that which employs steam is usually
solid wall. the most convenient. This method may, however, absorbs
(d) Wick burners. In this type of a burner a cotton some 4 to 5% of the total amount of steam generated. These
or asbestos wick is used which raises the liquid fuel by burners may be divided into two categories :
80 POWER PLANT ENGINEERING
(i) The outside mix In case of inside mixing type burners steam and oil
(ii) The inside mix. are mixed inside the burner before the mixture is projected
In case of outside mixing [Fig. 3.33 (a)] type burners, in the furnace in either a flat spray or in a hollow cone.
oil is ejected through one side of the holes and is blasted by These burners provide high efficiency at the high firing rates
a high velocity jet of steam issuing from other holes. Mixing, and flexible flame shape. In this type of burner instead of
however, occurs outside the burner. steam high pressure air can also be used.
(c) Low pressure air atomising burners. They
Steam operate on the same principle as for burners described
earlier. In this case air pressure required ranges from 0.015
bar to 0.15 bar.
These are the simplest and most versatile atomising
Oil type of burners and usually give troublefree service for long
interrupted periods.
3.9.4.3. Gas burners
Gas burning claims the following advantages :
(i) It is much simpler as the fuel is ready for
Oil
combustion and requires no preparation.
(ii) Furnace temperature can be easily controlled.
Steam (iii) A long slow burning flame with uniform and
gradual heat liberation can be produced.
Oil
(iv) Cleanliness.
(v) High chimney is not required.
(vi) No ash removal is required.
For generation of steam, natural gas is invariably
used in the following cases :
Steam
(i) Gas producing areas.
(a)
(ii) Areas served by gas transmission lines.
(iii) Where coal is costlier.
Typical gas burners used are shown in Figs. 3.34
to 3.36.
Oil
Gas
Steam
Gas
Oil Air
Air
Air
Steam
Air
Air
Oil
Flue gases
Walls
Steam
Gas
Ash over-
Fig. 3.36 flow Bubble
Refer to Fig. 3.35. This is a ring type burner in which Heat absorbing
a short flame is obtained. Water tubes
Refer to Fig. 3.36. This arrangement is used when Fuel and
both gas and air are under pressure. dolomite
In order to prevent the flame from turning back the Distributor
velocity of the gas should be more than the “rate of flame plate
propagation”.
Steam
generator Fly ash removal (Partial)
Fly ash 1. Stock sprays
suspended 2. Electrical precipitation
in gas stream
3. Wet baffles
All or bulk 4. Traps and centrifugal separators
Molten ash
of ash to 5. Special bladed fan
furnace hearth or
1. Continuous flow ash hopper Soot and fly ash
2. Periodically
tapped Solid ash
Conveying system 1. Hand raking
Conveying 2. Gravity dump
1. Water sluicing 3. Water jets
1. Ash dump system 2. Pivoted bucket conveyor
2. R.R. Car discharge to 3. Pneumatic conveyor
1. Hydraulic fill 4. Steam jet conveyor
3. Borge 2. Settling tank 5. Ash cars and carts
4. Motor truck 3. Dry ash pit 6. Wheel borrows
4. Ash bunker
3.11.2. Ash Handling Systems The hot ash released from the boiler furnaces is
made to fall over the belt conveyor after cooling it through
The modern ash-handling systems are mainly classified
water seal. This cooled ash is transported to an ash bunker
into four groups : through the belt conveyor. From ash bunker the ash is
1. Mechanical handling system removed to the dumping site through trucks.
2. Hydraulic system
3. Pneumatic system 2. Hydraulic system
4. Steam jet system. In this system ash is carried with the flow of water
with high velocity through a channel and finally dumped
1. Mechanical handling system
in the sump. This system is subdivided as follows :
Fig. 3.39 shows a mechanical handling system. This
system is generally employed for low capacity power plants (a) Low pressure system
using coal as fuel. (b) High pressure system.
Boiler furnaces (a) Low pressure system. Refer to Fig. 3.40. In
this system a trough or drain is provided below the boilers
Ash Ash Ash and the water is made to flow through the trough. The ash
directly falls into the troughs and is carried by water to
Ash sumps. In the sump the ash and water are made to pass
Belt conveyor
Water trough bunker through a screen so that water is separated from ash ; this
Control water is pumped back to the trough for reuse and ash is
valve removed to the dumping yard.
Truck
Ash
sump Water
Ash
sump Water
One stand by trough
Water
to permit repairs
Water
The ash carrying capacity of this system is 50 tonnes/ the top and on the sides. The top nozzles quench the ash
hour and distance covered is 500 metres. while the side ones provide the driving force for the ash.
(b) High pressure system. Refer to Fig. 3.41. The The cooled ash is carried to the sump through the trough.
hoppers below the boilers are fitted with water nozzles at The water is again separated from ash and recirculated.
84 POWER PLANT ENGINEERING
The ash carrying capacity of this system is as large 7. Its ash carrying capacity is considerably large,
as 120 tonnes per hour and the distance covered is as large hence suitable for large thermal power plants.
as 1000 metres.
3. Pneumatic system
Nozzle Furnace Fig. 3.42 shows the schematic of a pneumatic ash
handling system. This system can handle abrasive ash as
High Ash
well as fine dusty materials such as fly-ash and soot. It is
pressure preferable for the boiler plants from which ash and soot
water Stoker must be transported some far off distance for final disposal.
The exhauster provided at the discharge end creates
High pressure
Nozzle
water
a high velocity stream which picks up ash and dust from
High all discharge points and then these are carried in the
pressure Nozzle conveyor pipe to the point of delivery. Large ash particles
water Cast iron walls
are generally crushed to small sizes through mobile
Trough crushing units which are fed from the furnace ash hopper
carrying
Main sump and discharge into the conveyor pipe which terminates into
water and ash a separator at the delivery end.
The separator working on the cyclone principle
Fig. 3.41. High pressure system. removes dust and ash which pass out into the ash hopper
at the bottom while clean air is discharged from the top.
Advantages of hydraulic system :
The exhauster may be mechanical or it may use
1. The system is clean and healthy.
steam jet or water jet for its operation. When a mechanical
2. It can also be used to handle stream of molten exhauster is used it is usually essential to use a filter or
ash. washer to ensure that the exhauster handles clear air. Such
3. Working parts do not come into contact with the type of exhauster may be used in a large station as the
ash. power requirements are less. Steam exhauster may be used
4. It is dustless and totally closed. in small and medium size stations. Where large quantities
5. It can discharge the ash at a considerable of water are easily and cheaply available water exhauster
distance (1000 m) from the power plant. is preferred.
6. The unhealthy aspects of ordinary ash basement The ash carrying capacity of this system varies from
work is eliminated. 25 to 15 tonnes per hour.
Secondary ash
Boiler Boiler separator
Crushers
Filter
4. The dustless operation is possible as the 3. Due to abrasive action of ash the pipes undergo
materials are handled totally in an enclosed conduit. greater wear (and to reduce this wearing action the pipes
5. The cost of plant per tonne of ash discharged is are lined with nickel alloy).
less in comparison to other systems.
3.12. DUST COLLECTION
Disadvantages :
1. There is a large amount of wear in the pipe work 3.12.1. Introduction
necessitating high maintenance charges.
2. More noisy than other systems. The products of combustion of coal-fed fires contain
particles of solid matter floating in suspension. This may
4. Steam jet system be smoke or dust. If smoke, the indication is that combustion
In this case steam at sufficiently high velocity is conditions are faulty, and the proper remedy is in the design
passed through a pipe and dry solid materials of and management of the furnace. If dust, the particles are
considerable size are carried along with it. In a high mainly fine ash particles called “Fly-ash” intermixed with
pressure steam jet system a jet of high pressure steam is some quantity of carbon-ash material called “cinder”.
passed in the direction of ash travel through a conveying Pulverised coal and spreader stoker firing units are the
pipe in which the ash from the boiler ash hopper is fed. principle types causing difficulty from this source. Other
The ash is deposited in the ash hopper. stokers may produce minor quantities of dust but generally
This system can remove economically the ash not enough to demand special gas cleaning equipment. The
through a horizontal distance of 200 m and through a two mentioned are troublesome because coal is burned in
vertical distance of 30 m.
suspension—in a turbulent furnace atmosphere and every
Advantages : opportunity is offered for the gas to pick up the smaller
1. Less space requirement. particles and sweep them along with it.
2. Less capital cost in comparison to other systems. The size of the dust particles is measured in microns.
3. Auxiliary drive is not required. The micron is one millionth of a metre. As an indication of
4. It is possible to place the equipment in awkward the scale of this measure, the diameter of a human hair is
position too. approximately 80 microns. Typical classification of particles
by name is given in Fig. 3.43, but the limits shown are, for
Disadvantages : the most part, arbitrary. A critical characteristic of dust is
1. Noisy operation. its “Settling Velocity” in still air. This is proportional to the
2. This system necessitates continuous operation product of the square of micron size and mass density.
since its capacity is limited to about 7 tonnes per hour.
100
50 Spreader
Size – Microns
Smoke Dust
stoker
Cinder
10
Range – Electrostatic 5
Mechanical
Pulv. coal
1
01 1 1 10 100 1000 1 10 100
(a) Particle size – Microns (b) Per cent smaller than
Fig. 3.43. Typical particle sizes : (a) Flue gas particles and ranges of collecting equipment.
(b) Typical distribution of particle size in products of combustion.
The factors which affect the performance of this 3. Less flexible (in terms of volume handled).
collector are gas volume, particulate loading, inlet velocity, 4. High pressure loss comparatively (from 2 cm to
temperature, diameter to height ratio of cyclone and dust 15 cm of water).
characteristics. 5. Requires considerable head room and must be
The advantages and disadvantages of cyclone placed outside the boiler room.
collectors are given below : 6. As the fineness of the dust particle increases its
collection efficiency decreases.
Advantages :
1. Rugged in construction. 2. Electrical dust collector
2. Maintenance costs are relatively low. Electrostatic precipitators. This type, also called
3. Efficiency increases with increase in load. “Cottrell precipitators”, works effectively on the finer flue
dusts. Fig. 3.46 shows the basic elements of an
4. Easy to remove bigger size particles.
electrostatic precipitator. These are :
Disadvantages : (i) Source of high voltage,
1. Requires more power than other collectors. (ii) Ionizing and collecting electrodes,
2. Incapable to remove dust and ash particles which (iii) Dust-removal mechanism, and
remain in suspension with still air. (iv) Shell to house the elements.
40 – 80 kV, D.C.
Insulators
440 V, 50 Hz, 3 supply
Collected dust
This is an apparatus for withdrawing a sample of some cases a low resistance inertial and an electrostatic
dusty gas and filtering out the dust. Weighing of the filter precipitator have been installed in series, again with pros
before and after a timed collection period, together with and cons as to which should be ahead of the other.
the data on relative area of sampling nozzle to flue gas Generally, the mechanical type is placed first in the gas
passage, will suffice to establish the collection efficiency if flow. Another characteristic of interest in a combination is
the gas passage is traversed both at the inlet and discharge the variation of collection efficiency with the gas flow. As
of the dust collector, load remaining steady meanwhile. the flow increases, the electrostatic efficiency decreases, the
cyclone efficiency increases.
In order to obtain average samples the duct cross-
sectional area must be subdivided into elements and a During the original power plant layout a dust
collector should receive careful consideration.
reading taken at the geometrical centre of each.
Furthermore in a true sample the gas velocity into sampling 3.12.6. Uses of Ash and Dust
tube must be the same as that of the surrounding gas flow. The uses of ash and dust are listed below :
This considerably complicates the testing, for preliminary
1. Ash is widely used in the production of cement.
pitot-static traverse must be made and then the rate of
2. Ash is used in the production of concrete. 20 per
flow into the sample nozzle adjusted for the same velocity.
cent fly-ash and 30 per cent bottom ash are presently used
This explains the reason for some of the components shown constructively in U.S.A.
on the sampler.
3. Because of their better alkali values, they are
3.12.5. Installation of Dust Collectors used for treating acidic soils. It has been found that if ash
is used in limited quantity in soil, it increases the yield of
Dust collectors are installed between the boiler and the corn, turnip etc.
chimney, usually on the chimney side of the air heater, if
4. From the ash, the metals such as Al, Fe, Si and
there is one. There would be some advantages from the
titanium can be recovered.
stand point of heater cleanliness were the collector to be
put ahead of it, however, the practice seems to be to follow 3.12.7. General Layout of Ash Handling and Dust
with the collector, and use blowers to keep the heater Collection System
surfaces clean. Where there is more than one boiler, the
Fig. 3.49 shows the general layout of ash handling and
practice is to use an individual collector for each boiler. In
dust collection system which is self explanatory.
STEAM POWER PLANT 89
Furnace
Dust
collector Chimney
Molten slag
Fig. 3.49. General layout of ash handling and dust collection system.
● As a simultaneous replacement of cement and fine ash, sand and lime are mixed approximately in
aggregate. the ratio of 80 : 13 : 7. The bricks are made by
using hydraulic press and the semi-dried bricks
2. Cellular concrete blocks : are cured in a steam chamber at an appropriate
These blocks are light in weight and are produced temperature and pressure.
● As compared to conventional bricks, these bricks
by autoclaving a set mix of a fine silicons material such as
fly-ash and binder in the form of lime. are :
— superior in shape, technical specifications,
Advantages : impermeability and compressive strength ;
(i) Low thermal conductivity. — light in weight (20 per cent) ; and
(ii) Stable against temperature and humidity — cheaper (about 10 to 15 per cent).
variations.
(iii) Better sound insulation.
3.13. CHIMNEY DRAUGHT
(iv) Better strength to weight ratio. 3.13.1. Definition and Classification of Draught
(v) Since the cellular concrete blocks are machine The small pressure difference which causes a flow of gas to
finished and uniform in size, therefore, less quantity of take place is termed as a draught. The function of the
cement mortar is required. Further as the blocks are draught, in case of a boiler, is to force air to the fire and to
smooth and uniformly coloured, plaster can be avoided carry away the gaseous products of combustion. In a boiler
completely. furnace proper combustion takes place only when sufficient
quantity of air is supplied to the burning fuel.
Draught
Natural Artificial
or
Chimney draught
Balanced
Induced Forced Induced (Induced and force fan) Force
fan fan
patm
Equivalent column
Chimney
H
Boiler
Economiser
Main flue Grate level
Fig. 3.50
Net pressure difference causing the flow through Inserting the values of a and g into eqn. (3.1), we
the combustion chamber, get :
p = p2 – p1 = (a – g) gH ...(3.1) LM 1 1 . F m 1I OP
MN T T GH m JK PQ
a
This difference of pressure causing the flow of gases p = 353 gH ...(3.4)
is known as ‘static draught’. Its value is small and is a g a
generally measured by a water manometer. Assuming that the draught pressure p produced
It may be noted that this pressure difference in is equivalent to H1 metre height of burnt gases, we have
chimney is generally less than 12 mm of water. FG m 1IJ · 1
a
3.13.3. Chimney Height and Diameter
p = g · gH1 = 353
H m K T a g
g H1 ...(3.5)
Let us assume that the volume of products of combustion Equations (3.4) and (3.5), we get :
is equal to the volume of air supplied both reduced to the F m 1I 1
same temperature and pressure conditions. 353 GH m JK
a
a Ta
g· H1
Let, ma = Mass of air supplied per kg of fuel,
Ta = Absolute temperature of atmospheric LM 1 1 F m 1I OP
air, and = 353 g H
MNT a
Tg
GH m JK PQ
a
a
Tg = Average absolute temperature of
chimney gases. 353 FG m 1IJ g H = 353 g H – 353 g H F m 1I
Mass of hot gases m 1 Ta H m K
a
a T 1 T GH m JK
g g
a
a
Also, = a , temperature
Mass of air ma 353 F m 1I g H
and pressure being same.
The mass density of air at atmospheric conditions
Ta GH m JK
a
a
1
a
RTa 287 Ta Ta
H = H MG
LF m I T 1OP
MNH m 1JK T PQ
...(3.2) a g
1 ...(3.6)
The mass density of hot gases at temperature Tg is a a
given by Due to losses at various sections along the path of
p FG m 1IJ
a
the flue gas, the actual draught available is always less
g =
RTg
.
H m K a
than that given by the eqn. (3.4).
If hw is the height, in mm of a column of water which
1.01325 105 F m 1I will produce the pressure p, then
=
287
.
1
Tg
. GH m JK
a
a LM 1 F I OP
1 ma 1
F
1 . ma 1 I hw = 353 H
MNT
Tg ma
GH JK PQ ...(3.7)
= 353 ·
Tg GHma JK ...(3.3)
a
The height hw would be shown by the use of a The mass of gas discharged per second,
U-tube manometer. mg = A × C × g
Inserting the values of C and g from eqns. (3.11)
Note. The formula as expressed by eqn. (3.7) is used for and (3.12), we get
numerical calculation work only.
LMF m I T 1OP p
MNGH m 1JK T PQ
a g
Chimney diameter : mg = A 2 gH
a a
RTg
Assuming no loss, the velocity of the gases passing
through the chimney is given by
K F m I T 1
C= 2 gH1
mg =
Tg GH m 1JK T
a
a g
a
...(3.13)
where K = 4.43 1
H1
g a
Q a
d LM 1 F m I T 1 OP = 0
The value of K : 0.825 ........ For brick chimneys, and
or, dTg MNT GH m 1JK T Pa g
1.1 ........ For steel chimneys. g a
Q a
The mass of the gases flowing through any
cross-section of the chimney is given by : d LM (ZT 1) OP g
1/ 2
dT M
N T PQ
or, =0
g = g · A · C kg/s
m g g
ma 1
or, g = · D2. C
m where Z = .
g
4 ma 1 Ta
g
m d
4 or, [(ZTg – 1)1/2 × Tg–1] = 0
D2 = × dTg
g.C
m g or, (Z · Tg – 1)1/2 · (– 1)(Tg)–2 + Tg–1
or, D = 1.128 ...(3.10)
g . C × 1 (ZTg – 1)–1/2 × Z = 0
2
3.13.4. Condition for Maximum Discharge Through a ( ZTg 1)1/ 2 Z
or, 2 + =0
Chimney Tg 2Tg ( ZTg 1)1/ 2
The chimney draught is most effective when the maximum
weight of hot gases is discharged in a given time, and it 2 ( ZTg 1) ZTg
or, =0
will be shown that this occurs when the absolute 2 (Tg )2 ( ZTg 1)1/ 2
temperature of the chimney gases bears a certain relation
or, – 2(ZTg – 1) + ZTg = 0
to the absolute temperature of the outside air.
or, – 2ZTg + 2 + ZTg = 0
We know that the velocity of gas through the
chimney, assuming the losses to be negligible, is given by or , ZTg = 2
C= 2 gH1 , where h = 0 ma Tg
or , . =2
Inserting the value of H1 from eqn. (3.6) ma 1 Ta
LMF m I T OP Tg F m 1I
GH m JK
MNGH m 1JK T
a
C= 2 gH a g
1 ...(3.11) i.e., =2 ...(3.14)
a a PQ Ta
Thus we see that the absolute temperature of the
a
Tg LMF m I T 1OP
MNGH m 1JK T PQ
a g
Putting the value of in eqn. (3.6), we get : =H ...Energy units
Ta a a
LMF m I 2 F m 1I 1OP H LF m I T 1O
MNGH m 1JK GH m JK PQ MG J PP
a a a g
(H1)max = H
J NMH m 1 K T Q
= ...Heat units
a a a a
= H (2 – 1) = H Efficiency of chimney,
i.e., (H1)max = H ...(3.15) H LF m I T OP
The draught in mm of water column for maximum MG J
J MNH m 1 K T
a
a g
a
1
PQ
discharge can be evaluated by inserting the value of Tg/Ta = ch ...(3.17)
in eqn. (3.7) c p (T T )
FG 1 1 IJ In the equation, T = Tg.
(hw)max = 353 H
HT a
2 Ta K (In SI units J = 1)
l The efficiency of a chimney is proportional to the
176.5 H
= mm of water ...(3.16) height but even for a very tall chimney the
Ta efficiency will be less than 1% and thus we see
3.13.5. Efficiency of a Chimney that chimney is very inefficient as an instrument
for creating draught.
The temperature of the flue gases leaving a chimney, in
case of natural draught, is higher than that of flue gases 3.13.6. Draught Losses
leaving it in case of artificial draught system because a The loss in a draught may be due to the reasons mentioned
certain minimum temperature is needed to produce a given below :
draught with the given height of a chimney. As far as steam (i) The frictional resistance offered by the flues and
generation is concerned, in case of a natural draught system gas passages to the flow of flue gases.
the heat carried away by flue gases is more due to higher (ii) Loss near the bends in the gas flow circuit.
flue gas temperature. This indicates that the draught is (iii) Loss due to friction head in equipments like
created at the cost of thermal efficiency of the boiler plant grate, economiser, superheater etc.
installation since a portion of the heat carried away by the
(iv) Loss due to imparting velocity to the flue gases.
flue gases to produce the required draught could have been
The loss in draught in a chimney is 20 per cent of
used either in heating the air going to furnace or in heating
the total draught produced by it.
the feed water going to boiler ; thereby improving the
thermal efficiency of the installation. Let, 3.13.7. Artificial Draught
T = Absolute temperature of flue gases leaving the In the boiler installations of today the total static draught
chimney to create the draught of required may vary from 30 to 350 mm of water column.
hw mm of water, It may not be possible to build a chimney high
T = Absolute temperature of flue gases leaving the enough to produce draught of such a large magnitude. To
chimney in case of artificial draught of hw mm meet this requirement artificial draught system should
of water, and be used. It may be a mechanical draught or a steam jet
cp = Mean specific heat of flue gases. draught. The former is used for central power stations and
many other boiler installations while the latter is employed
The extra heat carried away by 1 kg of flue gas due
for small installations and in locomotives.
to higher temperature required to produce the natural
draught 3.13.8. Forced Draught
= cp (T – T ), since T is greater than T . In a mechanical draught system, the draught is produced
The draught pressure produced by the natural by a fan. In a forced draught system, a blower or a fan is
draught system in height of hot gases column, installed near or at the base of the boiler to force the air
LMF m I T OP through the cool bed and other passages through the
MNGH m 1JK T
a g
1 metre furnace, flues, air preheater, economiser etc. It is a positive
H1 = H
a a PQ pressure draught. The enclosure for the furnace etc. has to
The maximum energy this head would give to 1 kg be very highly sealed so that gases from the furnace do not
of flue gas which is at the expense of extra heat carried leak out in the boiler house.
away from the boiler plant
94 POWER PLANT ENGINEERING
WORKED EXAMPLES
Example 3.1. Calculate the mass of flue gases flowing Flue gases formed per kg of fuel burnt,
through the chimney when the draught produced is equal (ma + 1) = 23 kg
to 1.9 cm of water. Temperature of flue gases is 290°C and
ambient temperature is 20°C. The flue gases formed per kg Diameter of the chimney, D = 1.8 m
of fuel burnt are 23 kg. Neglect the losses and take the Mass of flue gases, mg :
diameter of the chimney as 1.8 m. Using the relation,
Solution. Draught in mm of water,
LMR m T U 1OP
MNST m 1 T VW PQ
a g
hw = 1.9 cm = 19 mm H1 = H
a a
Temperature of flue gases,
where H1 is the head in terms of gas column.
Tg = 290 + 273 = 563 K
Ambient temperature, LM 1 1 F m 1I OP
MN T T GH m JK PQ
a
Also, hw = 353 H
Ta = 20 + 273 = 293 K a g a
STEAM POWER PLANT 95
FG 1 1 23 IJ ma 1 FG 1 16 IJ
19 = 353 H
H 293 563 22 K ma
= 573
H 300 353 32 K
FG∵ m 1 23 kg (given)IJ
a = 573 (0.003333 – 0.001416)
H i. e. m 22 kg a K ma =
= 1.0984
10.16 kg/kg of fuel
19 = 353 H (0.00341 – 0.00185) = 0.548 H
Again, C + O2 = CO2
or, H = 34.67 m
FG 22 563 1IJ = 29.05 m of air. 12 + 32 = 44
H1 = 34.67
H 23 293 K Thus 1 kg of carbon requires
32
12
=
8
3
kg of oxygen
Velocity of gases, 8 100
and × = 11.6 kg of air. One kg of fuel contains only
C= 2 gH1 = 2 9.81 29.05 = 23.87 m/s. 3 23
0.81 carbon.
Now, mass of flue gases, mg = A × C × g Air required for complete combustion
F m 1I 1 23 = 11.6 × 0.81 = 9.396 kg/kg of fuel.
where, g = 353 GH m JK
a
a
·
Tg
= 353 ×
22
×
1
563
Hence, percentage excess air supplied
10.16 9.396
= 0.655 kg/m3 = × 100 = 8.13%. (Ans.)
9.396
mg = /4 × (1.82) × 23.87 × 0.655 Example 3.3. Determine the height and diameter of the
= 39.8 kg/s. (Ans.) chimney used to produce a draught for a boiler which has
an average coal consumption of 1800 kg/h and flue gases
Hence mass of flue gases passing through the
formed per kg of coal fired are 14 kg. The pressure losses
chimney = 39.8 kg/s. (Ans.)
through the system are given below :
Example 3.2. A chimney of height 32 m is used for
Pressure loss in fuel bed = 7 mm of water, pressure
producing a draught of 16 mm of water. The temperatures
loss in boiler flues = 7 mm of water, pressure loss in bends
of ambient air and flue gases are 27°C and 300°C
= 3 mm of water, pressure loss in chimney = 3 mm of water.
respectively. The coal burned in the combustion chamber
contains 81% carbon, 5% moisture and remaining ash. Pressure head equivalent to velocity of flue gases
Neglecting losses and assuming the value of burnt products passing through the chimney = 1.3 mm of water.
equivalent to the volume of air supplied and complete The temperatures of ambient air and flue gases are
combustion of fuel find the percentage of excess air supplied. 35°C and 310°C respectively.
Solution. Height of the chimney, Assume actual draught is 80% of theoretical.
H = 32 m Solution. Average coal consumption
Draught in mm of water = 1800 kg/h
= 16 mm Flue gases formed per kg of coal fired
Ambient air temperature, = 14 kg
Ta = 27 + 273 = 300 K Temperature of ambient air,
Temperature of flue gases, Ta = 35 + 273 = 308 K
Tg = 300 + 273 = 573 K Temperature of flue gases,
Percentage of carbon in the fuel = 81% Tg = 310 + 273 = 583 K.
Percentage of excess air supplied : Height of chimney, H :
Using the relation, Draught required is equivalent to overcome the
LM 1 F m 1I OP mm of water
1
losses and velocity head
hw = 353 H
MNT
a
GH m JK PQ
Tg
a
a
= 7 + 7 + 3 + 3 + 1.3 = 21.3 mm of water.
Actual draught to be produced,
L 1 1 F m 1I OP
16 = 353 × 32 M
MN 300 573 GH m JK PQ
a 21.3
hw = = 26.62 mm of water
a 0.8
16 1 1 F m 1I F1 I
353 32
= G
300 573 H m K
J a
a
hw = 353 H GH T
1 ma 1
Tg
.
ma JK
a
96 POWER PLANT ENGINEERING
353 FG m 1IJ
a 353 14
(i) Power of motor required to drive induced
g =
Tg H m K a
=
583
×
13
draught fan, PID :
Using the relation :
= 0.652 kg/m3
0.998 10 8 hV0 ma MTg
Flue gases formed per second PID = kW
f
1800 14
= = 7 kg
3600 0.998 108 54 0.7734 18.5 1820 513
=
mg = A × C × g ...(i) 0.82
(where V0 = 0.7734 m3 at 0°C and 760 mm of Hg)
But C = 2 gH1
= 8.78 kW. (Ans.)
where H1 is the equivalent velocity expressed in m of gas
H1g = hww (ii) Power of a motor required to drive forced
where hw is the water head equivalent to velocity head draught fan, PFD :
responsible for giving velocity to the gas, 0.998 10 8 hV0 ma MTa
hww 1.3 1000 PFD = kW
H1 = = = 1.993 m f
g 1000 0.652
0.998 108 54 0.7734 18.5 1820 293
=
C= 2 9.81 1.993 = 6.25 m/s 0.82
Substituting this value in eqn. (i), we get = 5.014 kW. (Ans.)
2 Power required to drive fan :
7= D × 6.25 × 0.625
4 Let, p = Draught, a ,
74 hf = Draught produced by the fan, mm
or D2 =
6.25 0.652 V = Volumetric flow rate of combustion air at
D = 1.478 m. (Ans.) fan conditions, m3/h, and
Example 3.4. Calculate power of a motor required to drive f = Fan efficiency.
a fan which maintains a draught of 54 mm of water under Power required
the following conditions for (i) induced draught fan, ghf V 1000 g hf V
pV
(ii) forced draught fan : = = = W
f f 1000 f 3600
Temperature of flue gases leaving the boiler in each
case = 240°C ghf V
Temperature of air in the boiler house = 20°C = kW
f 1000 3600
Air supplied per kg of fuel in each case = 18.5 kg
hV
Mass of coal burnt per hour = 1820 kg = 2.725 × 10–6 kW ...(3.18)
f
Efficiency of the fan = 82 per cent
Drive formulae, for forced draft and induced draft (i) Forced draught (F.D.) fan power, PFD :
fans. Let, M = Quantity of fuel burnt per hour,
Solution. Temperature of gases, ma = Mass of air supplied, kg/kg of fuel,
Tg = 240 + 273 = 513 K Ta = Temperature of atmospheric air, and
Temperature of air, T0 = Temperature at N.T.P.
Ta = 20 + 273 = 293 K Volume of air at T0,
Mass of air used, ma M
ma = 18.5 kg V0 =
Mass of coal used,
TaV0ma M
M = 1820 kg V= m3/h
273
STEAM POWER PLANT 97
Substituting in eqn. (3.18), we get : The steam generated is employed for the following
Power of F.D. fan, purposes :
2.725 106 F hV m MT I kW (i) For generating power in steam engines or steam
PFD =
273 GH JK 0 a
f
a
turbines.
(ii) In the textile industries for sizing and bleaching
F hV m MT I kW etc. and many other industries like sugar mills ;
= 0.998 × 10–8 GH JK 0 a
f
a
chemical industries.
(iii) For heating the buildings in cold weather and
(ii) Induced draught (I.D.) fan power, PID : for producing hot water for hot water supply.
Let, m = Mass of air supplied per kg of fuel, The Primary requirements of steam generators or
Then, ma + 1 = Mass of the products of combustion. boilers are :
At the same temperature (i) The water must be contained safely.
g (ii) The steam must be safely delivered in desired
ma 1
= condition (as regards its pressure, temperature,
a ma quality and required rate).
273 1
But a = × 3.14.2. Classification of Boilers
Tg V0
The boilers may be classified as follows :
273 1
g = × 1. Horizontal, vertical or inclined
Tg V0
If the axis of the boiler is horizontal, the boiler is
Volume handled by I.D. fan called as horizontal, if the axis is vertical, it is called vertical
Total mass handled by I.D. fan boiler and if the axis is inclined it is known as inclined
=
Density of gases boiler. The parts of a horizontal boiler can be inspected and
repaired easily but it occupies more space. The vertical boiler
M (ma 1) M (ma 1)Tg V0 ma
= = occupies less floor area.
g 273 (ma 1)
2. Fire tube and water tube
MmaTg V0 In the fire tube boilers, the hot gases are inside the
=
273 tubes and the water surrounds the tubes. Examples :
Substituting in eqn. (3.18), we get Cochran, Lancashire and Locomotive boilers.
Power of I.D. fan, In the water tube boilers, the water is inside
2.725 10 6 hMmaTg V0 the tubes and hot gases surround them. Examples : Babcock
PID = and Wilcox, Stirling, Yarrow boiler etc.
273 f
3. Externally fired and internally fired
hV0ma MTg
= 0.998 × 10–8 The boiler is known as externally fired if the fire is
f
outside the shell. Examples : Babcock and Wilcox boiler,
Assuming same efficiency, for the same draught Stirling boiler etc.
(neglecting leakage), we have In case of internally fired boilers, the furnace is
Power of I.D. fan Tg located inside the boiler shell. Examples : Cochran,
= . Lancashire boiler etc.
Power of F.D. fan Ta
4. Forced circulation and natural circulation
3.14. BOILERS In forced circulation type of boilers, the
circulation of water is done by a forced pump. Examples :
3.14.1. Introduction Velox, Lamont, Benson boiler etc.
In simple a boiler may be defined as a closed vessel in In natural circulation type of boilers, circulation of
which steam is produced from water by combustion of fuel. water in the boiler takes place due to natural convention
According to American Society of Mechanical currents produced by the application of heat. Examples :
Engineers (A.S.M.E.) a ‘steam generating unit’ is defined Lancashire, Babcock and Wilcox boiler etc.
as : 5. High pressure and low pressure boilers
“A combination of apparatus for producing, The boilers which produce steam at pressures of 80
furnishing or recovering heat together with the apparatus bar and above are called high pressure boilers. Examples :
for transferring the heat so made available to the fluid being Babcock and Wilcox, Velox, Lamont, Benson boilers.
heated and vapourised.”
98 POWER PLANT ENGINEERING
The boilers which produce steam at pressure below l Mobile boilers or portable boilers include
80 bar are called low pressure boilers. Examples : Cochran, locomotive type, and other small units for
Cornish, Lancashire and Locomotive boilers. temporary use at sites (just as in small coalfield
6. Stationary and portable pits).
Primarily, the boilers are classified as either 7. Single-tube and multi-tube boilers
stationary (land) or mobile (marine and locomotive). The fire tube boilers are classified as single-tube
l Stationary boilers are used for power plant- and multi-tube boilers, depending upon whether the fire
steam, for central station utility power plants, tube is one or more than one. The examples of the former
for plant process steam etc. type are cornish, simple vertical boiler and rest of the boilers
are multi-tube boilers.
3.14.3. Comparison between ‘Fire-tube and Water-tube’ Boilers
1. Position of water and hot gases Hot gases inside the tubes and Water inside the tubes and hot
water outside the tubes. gases outside the tubes.
2. Mode of firing Generally internally fired. Externally fired.
3. Operating pressure Operating pressure limited Can work under as high
to 16 bar. pressure as 100 bar.
4. Rate of steam production Lower Higher.
5. Suitability Not suitable for large power Suitable for large power
plants. plants.
6. Risk on bursting Involves lesser risk on explosion Involves more risk on bursting
due to lower pressure. due to high pressure.
7. Floor area For a given power it occupies For a given power it
more floor area. occupies less floor-area.
8. Construction Difficult Simple
9. Transportation Difficult Simple
10. Shell diameter Large for same power Small for same power
11. Chances of explosion Less More
12. Treatment of water Not so necessary More necessary
13. Accessibility of various parts Various parts not so easily Various parts are more
accessible for cleaning, repair accessible.
and inspection.
14. Requirement of skill Require less skill for efficient Require more skill and careful
and economic working. attention.
10. The tubes of the boiler should not accumulate 3.14.7.1. Simple vertical boiler
soot or water deposits and should be sufficiently strong to
Refer to Fig. 3.51. It consists of a cylindrical shell, the
allow for wear and corrosion.
greater portion of which is full of water (which surrounds
11. The water and gas circuits should be such as to
the fire box also) and remaining is the steam space. At the
allow minimum fluid velocity (for low frictional losses).
bottom of the fire box is grate on which fuel is burnt and
3.14.6. Boiler Terms the ash from it falls in the ash pit.
Shell. The shell of a boiler consists of one or more steel
plates bent into a cylindrical form and riveted or welded C
together. The shell ends are closed with the end plates.
SV
Setting. The primary function of setting is to confine SSV
heat to the boiler and form a passage for gases. It is made
of brickwork and may form the wall of the furnace and the PG
combustion chamber. It also provides support in some types
of boilers (e.g., Lancashire boilers). Steam
Grate. It is the platform in the furnace upon which MH
fuel is burnt and it is made of cast iron bars. The bars are WLG
so arranged that air may pass on to the fuel for combustion.
The area of the grate on which the fire rests in a coal or Water
wood fired boiler is called grate surface. HH
Furnace. It is a chamber formed by the space above HH
the grate and below the boiler shell, in which combustion CT
takes place. It is also called a fire box.
Water space and steam space. The volume of the
shell that is occupied by the water is termed water space FB
while the entire shell volume less the water and tubes (if
FD CS
any) space is called steam space.
Mountings. The items such as stop valve, safety FCV
valves, water level gauges, fusible plug, blow-off cock, G
pressure gauges, water level indicator etc. are termed as AP
mountings and a boiler cannot work safely without them.
Accessories. The items such as superheaters,
economisers, feed pumps etc. are termed as accessories and CS = Cylindrical shell WLG = Water level gauge
they form integral part of the boiler. They increase the MH = Manhole C= Chimney
efficiency of the boiler. CT = Cross tubes HH = Hand hole
Water level. The level at which water stands in FB = Fire box FD = Fire door
the boiler is called water level. The space above the water AP = Ash pit G= Grate
level is called steam space. PG = Pressure gauge SSV = Steam stop valve
Foaming. Formation of steam bubbles on the SV = Safety valve FCV = Feed check valve
surface of boiler water due to high surface tension of the Fig. 3.51. Simple vertical boiler.
water. The fire box is provided with two cross tubes. This
Scale. A deposit of medium to extreme hardness increases the heating surface and the circulation of water.
occurring on water heating surfaces of a boiler because of The cross tubes are fitted inclined. This ensures efficient
an undesirable condition in the boiler water. circulation of water. At the ends of each cross tube are
Blowing off. The removal of the mud and other provided hand holes to give access for cleaning these tubes.
impurities of water from the lowest part of the boiler (where The combustion gases after heating the water and thus
they usually settle) is termed as ‘blowing off’. This is converting it into steam escape to the atmosphere through
accomplished with the help of a blow off cock or valve. the chimney. Man hole, is provided to clean the interior of
Lagging. Blocks of asbestos or magnesia insulation the boiler and exterior of the combustion chamber and
wrapped on the outside of a boiler shell or steam piping. chimney. The various mountings shown in Fig. 3.51 are
Refractory. A heat insulation material, such as fire (i) Pressure gauge, (ii) Water level gauge or indicator,
brick or plastic fire clay, used for such purposes as lining (iii) safety valve, (iv) steam stop valve, (v) feed check valve,
combustion chambers. and (vi) water level gauge.
3.14.7. Fire Tube Boilers Flow of combustion gases and circulation of water
in water jackets are indicated by arrows in Fig. 3.51.
The various fire tube boilers are described as follows :
100 POWER PLANT ENGINEERING
The rate of production in such a boiler normally does and ash is collected and disposed of from ash pit. The gases
not exceed 2500 kg/h and pressure is normally limited to of combustion produced by burning of fuel enter the
7.5 to 10 bar. combustion chamber through the flue tube and strike
A simple vertical boiler is self-contained and can be against fire brick lining which directs them to pass through
transported easily. number of horizontal tubes, being surrounded by water.
After which the gases escape to the atmosphere through
3.14.7.2. Cochran boiler smoke box and chimney. A number of hand-holes are
It is one of the best types of vertical multi-tubular boiler, provided around the outer shell for cleaning purposes.
and has a number of horizontal fire tubes. The various boiler mountings shown in Fig. 3.52
are : (i) Water level gauge, (ii) Safety valve, (iii) Steam stop
SSV
SV valve, (iv) Blow off cock, (v) Manhole, and (vi) Pressure
PG APP
gauge.
The path of combustion of gases and circulation of
water are shown by arrows in Fig. 3.52.
MH Steam C 3.14.7.3. Cornish boiler
WLG This form of boiler was first adopted by Trevithick, the
FP Cornish Engineer, at the time of introduction of high-
pressure steam to the early Cornish engine, and is still
CC
SB used.
FBL
A
A
FT
FT
C
FT F CS
Water BF D BF
FH
BOC G SF
AP
(vi) High steam low water safety valve, (vii) Feed check from and it is placed horizontally over a brickwork which
valve, and (viii) Manhole. forms several channels for the flow of hot gases. These two
The advantage possessed by this type of boiler is that tubes are also constructed with several rings of cylindrical
the sediment contained in the water falls to the bottom, form. They pass from one end of the shell to the other and
where the plates are not brought into contact with the hottest are covered with water. The furnace is placed at the front
portion of the furnace gases. The reason for carrying the end of each tube and they are known as furnace tubes. The
product of combustion first through the side flues, and lastly coal is introduced through the fire hole into the grate. There
through the bottom flue, is because the gases, having parted is low brickwork fire bridge at the back of the gate to
with much of their heat by the time they reach the bottom prevent the entry of the burning coal and ashes into the
flue, are less liable to unduly heat the plates in the bottom interior of the furnace tubes.
of the boiler, where the sediment may have collected. The combustion products from the grate pass up to
the back end of the furnace tubes and then in downward
3.14.7.4. Lancashire boiler
direction. Thereafter they move through the bottom channel
This boiler is reliable, has simplicity of design, ease of or bottom flue up to the front end of the boiler where they
operation and less operating and maintenance costs. It is are divided and pass up to the side flues. Now they move
commonly used in sugar-mills and textile industries where along the two side flues and come to the chimney flue from
alongwith the power steam and steam for the process work where they lead to the chimney. To control the flow of hot
is also needed. In addition this boiler is used where larger gases to the chimney, dampers (in the form of sliding doors)
reserve of water and steam are needed. are provided. As a result the flow of air to the grate can be
The specifications of Lancashire boiler are given controlled. The various mountings used on the boiler are
below : shown in Fig. 3.54.
Diameter of the shell ...... 2 to 3 m
Note. In Cornish and Lancashire boilers, conical shaped
Diameter of the shell ...... 7 to 9 m
cross tubes known as galloway tubes (not shown) may be
Maximum working pressure ...... 16 bar
fitted inside the furnace tubes to increase their heating
Steam capacity ...... 9000 kg/h surfaces and circulation of water. But these tubes have
Efficiency ...... 50 to 70% now become absolute for their considerable cost of fitting.
Refer to Fig. 3.54. The Lancashire boiler consists of Moreover, they cool the furnace gases and retard
a cylindrical shell inside which two large tubes are placed. combustion.
The shell is constructed with several rings of cylindrical
5 4 2 1 Shell
6 3
8 7 10 10 10
Fire door F Flue
E tube
K C S S
Fire grate
B B
9
S D
Flue
tube
S D
B= Bottom flue 1. High steam low water safety valve 8. Water gauge
C= Chimney 2. Manhole 9. Blow down cock
D= Dampers 3. Antipriming pipe 10. Fusible plug
E= Fire-bridge 4. Steam stope valve
F= Flue tube 5. Safety valve
K= Main flue 6. Pressure gauge
S= Side flue 7. Feed check valve
Fig. 3.54. Lancashire boiler.
102 POWER PLANT ENGINEERING
Superheater
tubes Steam dome Pressure
Chamber Safety
Regulator Whistle valve gauge
Regulator
Man hole rod
Water level
Pipe Hot indicator
leading gases
to engine Smoke
Smoke brick Fire hole
box Fire h
box arc grate
door
Blow-off cock
Blast Ordinary fire tubes
pipe Ash pan
Air Air
Refer to Fig. 3.55. The locomotive boiler consists of returns to the superheated steam chamber (not shown)
a cylindrical barrel with a rectangular fire box at one end from which it is led to the cylinders through the pipes, one
and a smoke box at the other end. The coal is introduced to each cylinder.
through the fire hole into the grate which is placed at the In this boiler natural draught cannot be obtained
bottom of the fire box. The hot gases which are generated because it requires a very high chimney which cannot be
due to burning of the coal are deflected by an arch of fire provided on a locomotive boiler since it has to run on rails.
bricks, so that walls of the fire box may be heated properly. Thus some artificial arrangement has to be used to produce
The fire box is entirely surrounded by water except for the a correct draught. As such the draught here is produced by
fire hole and the ash pit which is situated below the fire exhaust steam from the cylinders which is discharged
box is fitted with dampers at its front and back ends. through the blast pipe to the chimney. When the locomotive
The dampers control the flow of air to the grate. The hot is standing and no exhaust steam is available from
gases pass from the fire box to the smoke box through a the engine fresh steam from the boiler is used for the
series of fire tubes and then they are discharged into the purpose.
atmosphere through the chimney. The fire tubes are placed The various boiler mountings include :
inside the barrel. Some of these tube are of larger diameter
Safety valves, pressure gauge, water level indicator,
and the others of smaller diameter. The superheater tubes
fusible plug, man hole, blow-off cock and feed check valve.
are placed inside the fire tubes of larger diameter. The heat
A locomotive boiler entails the following merits and
of the hot gases is transmitted into the water through the
demerits :
heating surface of the fire tubes. The steam generated is
collected over the water surface. Merits :
A dome shaped chamber known as steam dome is 1. High steam capacity.
fitted on the upper part of the barrel, from where the steam 2. Low cost of construction.
flows through a steam pipe into the chamber. The flow of 3. Portability.
steam is regulated by means of a regulator. From the 4. Low installation cost.
chamber it passes through the superheater tubes and 5. Compact.
STEAM POWER PLANT 103
SV APP MSV
D
PG
WLI
Water
FV
UTH U
ST L
BP
BP
WT
DTH
MC
FD
G
D D
The steam drums are connected to mud drum by bank of brickwall baffles and are finally discharged through the
bent tubes. The steam and water space of the steam drums chimney into the atmosphere. Fire brick arch gets
are interconnected with each other, so that balance of water incandescent hot and helps in combustion and preventing
and steam may be obtained. For carrying out cleaning the chilling of the furnace when fire door is opened and
operation manhole at one end of each drum is provided. cold air rushes in.
The feed water from the economiser (not shown) is delivered The steam drums and mud drum are supported on
to the steam drum 1 which is fitted with a baffle. The baffle steel beams independent of the brick-work.
deflects the water to move downwards into the drum. The It is lighter and more flexible than the straight tube
water flows from the drum 1 to the mud drum through the boilers. But it is comparatively more difficult to clean and
rearmost water tubes at the backside. So the mud particles inspect the bent tubes.
and other impurities will move to the mud drum, where
these particles may be deposited. As this drum is not 3.14.9. High Pressure Boilers
subjected to high temperature, so the impurities may not
cause harm to the drum. The blow off cock blows off the 3.14.9.1. Introduction
impurities. The baffle provided at the mud drum deflects In applications where steam is needed at pressure, 30 bar,
the pure water to move upwards to the drum 1 through and individual boilers are required to raise less than about
the remaining half of the water tubes at the back. The water 30000 kg of steam per hour, shell boilers are considerably
also flows from it to the drum 2 through the water tubes cheaper than the water tube boilers. Above these limits,
which are just over the furnace. So they attain a higher shell boilers (generally factory built) are difficult to
temperature than the remaining portion of the boiler and transport if not impossible. There are no such limits to
a major portion of evaporation takes place in these tubes. water tube boilers. These can be site erected from easily
The steam is taken from the drum 1 through a steam pipe transportable parts, and moreover the pressure parts are
and then it passes through the superheater tubes where
of smaller diameter and therefore can be thinner. The
the steam is superheated. Finally, the steam moves to the
geometry can be varied to suit a wide range of situations
stop valve from where it can be supplied for further use.
and furnace is not limited to cylindrical form. Therefore,
water tube boilers are generally preferred for high pressure
V P
and high output, whereas, shell boilers for low pressure and
low output.
The modern high pressure boilers employed for
1 b power generation are for steam capacities 30 to 650
2
tonnes/h and above with a pressure up to 160 bar and
B maximum steam temperature of about 540°C.
B
ST 3.14.9.2. Unique features of the high pressure boilers
Following are the unique features of high pressure boilers :
1. Method of water circulation
T
2. Type of tubing
3. Improved method of heating.
T
1. Method of water circulation. The circulation
of water through the boiler may be natural circulation due
F to density difference or forced circulation. In all modern
G b
M high pressure boiler plants, the water circulation is
maintained with the help of pump which forces the water
through the boiler plant. The use of natural circulation is
limited to sub-critical boilers due to its limitations.
2. Type of tubing. In most of the high pressure
boilers, the water circulated through the tubes and their
V= Stop valve ST = Superheater tubes external surfaces are exposed to the flue gases. In water
P= Steam pipe T= Water tubes tube boilers, if the flow takes place through one continuous
b= Water baffle G= Grate tube, the large pressure drop takes place due to friction.
B= Baffle wall M= Mud drum This is considerably reduced by arranging the flow to pass
Fig. 3.58. Stirling boiler. through parallel system of tubing. In most of the cases,
several sets of the tubings are used. This type of
The combustion products ensuing from the grate arrangement helps to reduce the pressure loss, and better
move in the upward and downward directions due to the control over the quality of the steam.
106 POWER PLANT ENGINEERING
3. Improved method of heating. The following 7. The differential expansion is reduced due to
improved methods of heating may be used to increase the uniform temperature and this reduces the
heat transfer : possibility of gas and air leakages.
(i) The saving of heat by evaporation of water above 8. The components can be arranged horizontally
critical pressure of the steam. as high head required for natural circulation is
(ii) The heating of water can be made by mixing the eliminated using forced circulation. There is a
superheated steam. The mixing phenomenon gives highest greater flexibility in the components arrangement.
heat transfer co-efficient. 9. The steam can be raised quickly to meet the
variable load requirements without the use of
(iii) The overall heat transfer coefficient can be
complicated control devices.
increased by increasing the water velocity inside the tube
10. The efficiency of plant is increased up to 40 to
and increasing the gas velocity above sonic velocity.
42 per cent by using high pressure and high
3.14.9.3. Advantages of high pressure boilers temperature steam.
11. A very rapid start from cold is possible if an
The following are the advantages of high pressure boilers :
external supply of power is available. Hence, the
1. In high pressure boilers pumps are used to boiler can be used for carrying peak loads or
maintain forced circulation of water through the standby purposes with hydraulic station.
tubes of the boiler. This ensures positive 12. Use of high pressure and high temperature
circulation of water and increases evaporative steam is economical.
capacity of the boiler and less number of steam
drums will be required. 3.14.9.4. LaMont boiler
2. The heat of combustion is utilised more efficiently This boiler works on a forced circulation and the circulation
by the use of small diameter tubes in large is maintained by a centrifugal pump, driven by a steam
number and in multiple circuits. turbine using steam from the boiler. For emergency an
3. Pressurised combustion is used which increases electrically driven pump is also fitted.
rate of firing of fuel thus increasing the rate of Fig. 3.59 shows a LaMont steam boiler. The feed
heat release. water passes through the economiser to the drum from
4. Due to compactness less floor space is required. which it is drawn to the circulation pump. The pump
5. The tendency of scale formation is eliminated delivers the feed water to the tube evaporating section
due to high velocity of water through the tubes. which in turn sends a mixture of steam and water to the
6. All the parts are uniformly heated, therefore, the drum. The steam in the drum is then drawn through the
danger of overheating is reduced and thermal superheater. The superheated steam so obtained is then
stress problem is simplified. supplied to the prime mover.
Convection
superheater
Steam to
Drum prime mover
Water +
steam
Water Steam
Economiser Water
Flue gas
Feed
Tube
Water evaporating
circulating section
pump
Steam Feed
circulating Economiser Drain
pump
Evaporating
drum
Boiler feed pump
Fig. 3.60. Loeffler boiler. Fig. 3.61. Once through (or Monotype) boiler.
108 POWER PLANT ENGINEERING
Super-heater Mixing
chamber l This type of boiler is more suitable when the
plant is designed to take peak loads.
Boiler
wall Feed 3.14.9.6. Benson boiler
pump In the LaMont boiler, the main difficult experienced is the
formation and attachment of bubbles on the inner surfaces
of the heating tubes. The attached bubbles to the tube
surfaces reduce the heat flow and steam generation as it
Distributing Boiler circulating offers high thermal resistance than water film. Benson in
header pump
1922 argued that if the boiler pressure was raised to critical
Fig. 3.62. Combined circulatory pump. pressure (225 atm.), the steam and water have the same
density and therefore, the danger of bubble formation can
Advantages of Once through boilers : be easily eliminated. The first high pressure Benson boiler
The following are the advantages of once through was put into operation in 1927 in West Germany.
boilers for large thermal units : This boiler too makes use of forced circulation and
1. No higher limit for the higher steam pressure. uses oil as fuel. It chief novel principle is that it eliminates
2. Full steam temperature can be maintained over the latent heat of water by first compressing the feed to a
a wider range of load. pressure of 235 bar, it is then above the critical pressure
3. Starting and cooling down of the boiler is fast. and its latent heat is zero.
4. No circulation disturbance due to rapid pressure Fig. 3.63 shows a schematic diagram of a Benson
fluctuations. boiler. This boiler does not use any drum. The feed water
5. A once through boiler is smaller in size and weighs after circulation through the economic tubes flows through
less in comparison to a natural circulation boiler. the radiant parallel tube section to evaporate partly. The
6. Easy control of steam temperature during start- steam water mixture produced then moves to the transit
up and shut-down (which is very advantageous for start- section where this mixture is converted into steam. The
up of boiler and turbine) steam is now passed through the convection superheater
7. Greater freedom in arrangement and location of and finally supplied to the prime mover.
heating surfaces.
Boilers having as high as 650°C temperature of
8. Easy to adopt variable pressure operation for steam had been put into service. The maximum working
better performance at part load operation. pressure obtained so far from commercial Benson boiler is
9. Elimination of heavy walled drum decreases the 500 atm. The Benson boilers of 150 tonnes/h generating
metallurgical sensitivity of boiler against changes in capacity are in use.
pressure.
STEAM POWER PLANT 109
Economiser
3.14.9.7. Velox boiler
Steam to It is a well known fact that when the gas velocity exceeds
prime mover the sound-velocity, the heat is transferred from the gas at
a much higher rate than rates achieved with sub-sonic flow.
Transit The advantage of this theory is taken to effect the large
section heat transfer from a smaller surface area in this boiler.
Water Steam to
prime mover
Convection Steam
Convection superheater Water
superheater Flue gas
Steam Tube
Radiant parallel separating evaporating
Feed section section
tube section
pump Flue gas
Feed
pump
Fig. 3.63. Benson boiler.
Water Economiser
Advantages of a Benson Boiler :
circulating Axial Gas
The Benson boiler possesses the following pump compressor turbine
advantages : Water
1. It can be erected in a comparatively smaller floor Fig. 3.64. Velox boiler.
area.
This boiler makes use of pressurised combustion.
2. The total weight of a Benson boiler is 20% less
than other boilers, since there are no drums. This also The gas turbine drives the axial flow compressor
reduces the cost of the boiler. which raises the incoming air from atmosphere pressure
to furnace pressure. The combustion gases after heating
3. It can be started very quickly because of welded
the water and steam flow through the gas turbine to the
joints.
atmosphere. The feed water after passing through
4. Natural convection boilers require expansion the economiser is pumped by a water circulating pump to
joints but these are not required for Benson boiler as the the tube evaporating section. Steam separated in steam
pipes are welded. separating section flows to the superheater, from there it
5. The furnace walls of the boiler can be more moves to the prime mover.
efficiently protected by using smaller diameter and closed The size of the Velox boiler is limited to 100 tonnes/
pitched tubes. h because 600 B.H.P. is required to run the air compressor
6. The transfer of parts of the boiler is easy as no at this output. The power developed by the gas turbine is
drums are required and majority of the parts are carried not sufficient to run the compressor and therefore, some
to the site without pre-assembly. power from external source power must be supplied.
7. It can be operated most economically by varying Advantages :
the temperature and pressure at part loads and overloads. 1. The boiler is very compact and has greater
The desired temperature can also be maintained constant flexibility.
at any pressure. 2. Very high combustion rates are possible.
8. The blow-down losses of the boiler are hardly 4% 3. It can be quickly started.
of natural circulation boiler of the same capacity. 4. Low excess air is required as the pressurised air
is used and the problem of draught is simplified.
9. Explosion hazards are not severe as it consists of
only tubes of small diameter and has very little storage 3.14.9.8. Supercritical boilers
capacity. A large number of steam generating plants are designed
10. The superheater in a Benson boiler is an integral between working ranges of 125 atm. and 510°C to 300
part of forced circulation system, therefore, no special atm. and 660°C ; these are basically characterised as
starting arrangement for superheater is required. subcritical and supercritical.
110 POWER PLANT ENGINEERING
Usually, a sub-critical boiler consists of three distinct It is of paramount importance to keep the tubes
section as preheater (economiser), evaporator and clean internally and externally free of deposits that could
superheater. impair heat transfer and lead to corrosion, ultimately
causing tube failures. Corrosion damage is always
A super-critical boiler requires only preheater and
experienced inside tubes of the boiler, economiser and
superheater. superheater when water chemistry is not maintained
The constructional layout of both the above types of within limit as recommended by the manufacturers.
boilers is, however, practically identical. Materials commonly used for various parts/sections
These days it has become a rule to use super-critical of the boilers are given below :
boilers above 300 MW capacity units. Parts/Sections Materials
The super-critical boilers claim the following
1. Furnace walls Carbon steels and ferric
advantages over critical type :
and economisers alloys with small percentages of
1. Large heat transfer rates. chromium (5–10%).
2. Owing to less heat capacity of the generator the 2. Superheater and — Carbon steels... up to
pressure level is more stable and therefore gives better reheater tubes 500°C temp.
response. — Alloy steels ... temp. >
3. Because of absence of two phase mixture the 500°C.
problems of erosion and corrosion are minimised. — Carbon-molybdenum steel
4. More adaptable to load fluctuations (because of is used at inlet section.
great ease of operation, simplicity and flexibility). — Ferritic alloy steel with
5. The turbo-generators connected to super-critical high percentage of
boilers can generate peak loads by changing the pressure chromium is used for
of operation. downstream section of
superheater.
6. Higher thermal efficiency.
— Stainless steel and high
Presently, 246 atm. and 538°C are used for unit size chromium steels are
above 500 MW capacity plants. recommended for hotter
sections (560–600°C).
3.14.9.9. Supercharged boiler
Composite tubes (consisting of an outer layer of 50%
In a supercharged boiler, the combustion is carried out Cr, 15% Ni steel, metallurgically bonded to inner layer of
under pressure in the combustion chamber by supplying 800 H) are used when coal-ash attack is severe.
the compressed air. The exhaust gases from the combustion
Following are the few important phenomena which
chamber are used to run the gas turbine as they are
contribute to corrosion :
exhausted to high pressure. The gas turbine runs the air
compressor to supply the compressed air to the combustion (i) Hydrogen induced brittle fracture.
chamber. (ii) Bulk deposit corrosion.
Advantages : (iii) Corrosion fatigue.
1. Owing to very high overall heat transfer co- (iv) Stress corrosion cracking.
efficient the heat transfer surface required is hardly 20 to (v) Oxidation.
25% of the heat transfer surface of a conventional boiler. (vi) Fouling.
2. The part of the gas turbine output can be used to (vii) Slagging.
drive other auxiliaries.
If inspite of design efforts high temperature
3. Small heat storage capacity of the boiler plant
corrosion occurs then the problem can be solved by using
gives better response to control.
any one of the following methods :
4. Rapid start of the boiler is possible. 1. Using the fuels having more favourable
5. Comparatively less number of operators are characteristics.
required. 2. Replacing the damaged tubes with tubes
Corrosion in boilers and its prevention containing high chromium content.
3. Providing stainless steel tube shields at the cost
For the safety and performance of fossil fired boilers
of reduced efficiency.
proper selection of tube material is very essential.
STEAM POWER PLANT 111
Steam Delivery
inlet Nut for adjusting valves
stroke
Lever
Valve
rod
Steam Water
cylinder cylinder
Fig. 3.65 shows a duplex direct acting steam pump. rotating element known as impeller which is fitted over a
Here there are two single steam cylinders placed side by shaft. It utilises the centrifugal force of the rotating impeller
side. Slide valves distribute the steam in each cylinder. for pumping the liquid from one place to the other.
The slide valve in each cylinder steam chest is operated by
the crosshead on the piston rod of the opposite cylinder, 3.15.2. Injector
through an arrangement of rods and rocker arms. The feed The function of an injector is to feed water into the boiler. It
pump is generally double-acting. On each side of the pump is commonly employed for vertical and locomotive boilers
plunger there are suction and discharge valves. The pumps and does not find its application in large capacity high
work alternately and consequently continuous flow of water pressure boilers. It is also used where the space is not
is maintained. Double feed pump is commonly employed
available for the installation of a feed pump.
for medium size boilers.
In an injector the water is delivered to the boiler by
Rotary feed pumps are of centrifugal type and are
commonly run either by a small steam turbine or by an steam pressure ; the kinetic energy of steam is used to
electric motor. A rotary pump consists of a casing and a increase the pressure and velocity of the feed water.
112 POWER PLANT ENGINEERING
water will not enter into the boiler. The excess water finds
H its way through the overflow pipe.
T
Advantages of an injector :
1. Low initial cost.
2. Simplicity.
3. Compactness.
E A 4. Absence of dynamic parts.
5. Thermal efficiency very high (about 99%).
6. Ease of operation.
Disadvantages :
B S
1. Pumping efficiency is low.
2. It cannot force very hot water.
K 3. Irregularity of operation under extreme variation
in steam pressure.
Note. An injector is more efficient than a feed pump
because all the heat in the operating steam is returned to
V boiler and in addition to performing the work of a pump,
C the injector acts as a feed water heater. But when a large
quantity of feed water is involved (e.g. marine and large
installations) feed pumps are employed because they have
greater reliability and require lesser amount of attention.
D
3.15.3. Economiser
S= Steam cone E= Key
K= Combining cone H= Handle An economiser is a device in which the waste heat of the
D= Delivery cone T= Pointer flue gases is utilised for heating the feed water.
P= Spindle V= Valve Economiser are of the two types : (i) Independent
A= Steam pipe C= Overflow pipe type, and (ii) Integral type. Former is installed in chamber
B= Water pipe apart from the boiler setting. The chamber is situated at
Fig. 3.66. Injector.
the passage of the flow of the flue gases from the boiler or
boiler to the chimney. Latter is a part of the boiler heating
Fig. 3.66 shows an injector. It consists of a spindle surface and is installed within the boiler setting.
P, a steam cone S, a combining cone K, a delivery cone D, Fig. 3.67 shows an independent type vertical tube
and a handle H, with a pointer T. The spindle’s upper end economiser (called Green’s economiser). It is employed for
is provided with a handle while the lower end serves the boilers of medium pressure range up to about 25 bar. It
purpose of a valve. The pointer on the handle indicates the consists of a large number of vertical cast iron pipes P which
‘shut’ and ‘open’ position of the valve. The lower part of the are connected with two horizontal pipes, one at the top
spindle has a screw which works in a nut which is integral and the other at the bottom. A is the bottom pipe through
part of the steam cone. The key E checks the rotation of which the feed water is pumped into the economiser. The
steam cone. With the rotation of the handle steam cone water comes into the top pipe B from the bottom pipe (via.
moves up or down and consequently the valve controls the vertical pipes) and finally flows to the boiler. The flue gases
steam flow through the steam cone. The steam enters move around the pipes in the direction opposite to the flow
through the steam pipe A, while the feed water enters of water. Consequently, heat transfer through the surfaces
through the water pipe B. The flow of water is also of the pipes takes place and water is thereby heated.
regulated due to sliding motion of the steam cone by its A blow-off cock is provided at the back of end vertical
lower end. The water mixes with the steam at the pipes to remove sediments deposited in the bottom boxes.
combining cone where it is condensed. The mixture then The soot of the flue gases which gets deposited on the pipes
passes through the delivery cone and there its kinetic reduces the efficiency of the economiser. To prevent the
energy is converted into pressure energy. The final pressure soot deposit, the scrapers S move up and down to keep the
must be greater than the steam pressure of boiler otherwise external surface of the pipe clean (for better heat transfer).
STEAM POWER PLANT 113
Flue gases
in
B
Heated air
out
S
A = Bottom pipe P
B = Top pipe Tubes
P = Vertical C.I. pipes
S = Scrapers S
Baffles
A
C
C
Fig. 3.69. Tubular type air preheater.
A
An air preheater consists of plates or tubes with
hot gases on one side and air on the other. It preheats the
air to be supplied to the furnace. Preheated air accelerates
the combustion and facilitates the burning of coal.
Degree of preheating depends on :
Lancashire Lancashire (i) Type of fuel,
boiler boiler (ii) Type of fuel burning equipment, and
(iii) Rating at which the boiler and furnace are
Fig. 3.68. By-pass arrangement of flues.
operated.
The use of an economiser entails the following There are three types of air preheaters :
advantages : 1. Tubular type
1. The temperature range between various parts of 2. Plate type
the boiler is reduced which results in reduction of stresses 3. Storage type.
due to unequal expansion. Fig. 3.69 shows a tubular type air preheater. After
2. If the boiler is fed with cold water it may result in leaving the boiler or economiser the gaseous products of
chilling the boiler metal. Hot feed water checks it. combustion travel through the inside of the tubes of air
3. Evaporative capacity of the boiler is increased. preheater in a direction opposite to that of air travel and
transfer some of their heat to the air to be supplied to the
4. Overall efficiency of the plant is increased.
furnace. Thus the air gets initially heated before being
3.15.4. Air Preheater supplied to the furnace. The gases reverse their direction
near the bottom of the air heater, and a soot hopper is
The function of the air preheater is to increase the fitted to the bottom of air heater casing to collect soot.
temperature of air before it enters the furnace. It is generally
In the plate type air preheater the air absorbs heat
placed after the economiser ; so the flue gases pass through
from the hot gases being swept through the heater at high
the economiser and then to the air preheater.
velocity on the opposite side of a plate.
114 POWER PLANT ENGINEERING
V3 V2
V1 Hand
Boiler wheel Headers
Wet
steam Water level
Steel tubes
Damper
Chimney flue
Bottom flue
Flue gases
Wet steam
Superheated steam
Fig. 3.71 shows Sugden’s superheater installed in a According to the principle of operation the steam
Lancashire boiler. It consists of two steel headers to which separators are classified as follows :
are attached solid drawn ‘U’ tubes of steel. These tubes 1. Impact or baffle type
are arranged in groups of four and one pair of the headers
generally carries ten of these groups or total of forty tubes. 2. Reverse current type
The steam from the boiler enters and leaves the headers 3. Centrifugal type.
as shown by the arrows. Fig. 3.71 also shows how the steam Fig. 3.72 shows baffle plate steam separator. The
pipes may be arranged so as to pass the steam through the steam enters the flange A and flows down. In its passage it
superheater or direct to the main steam pipe. When the strikes the baffles B ; as a result it gets deflected, but water
steam is taken from the boiler direct to the main steam particles having greater density and greater inertia fall to
pipe, the valves V1 and V2 are closed and V3 is opened ; the bottom of the separator. The drier steam discharges
when the steam is passed through the superheater i.e., through the flange C. To see the level of water collected a
when the superheater is in action the valve V3 is closed water gauge is provided. The water collected in the vessel
the valve V1 and V2 are opened. is removed at intervals through the drain pipe D.
The path of the gases is controlled by the damper
which is operated by the hand wheel.
3.16. FEED WATER HEATERS AND
3.15.6. Steam Separator EVAPORATORS
The steam available from a boiler may be either wet, dry ;
The main condensate in most of the power plants returns
or superheated ; but in many cases there will be loss of
to the steam generator as feed water. Some make-up water
heat from it during its passage through the steam pipe
may be added to replace losses in the cycle. In a few plants
from the boiler to the engine tending to produce wetness.
the boiler feed water may be 100 per cent make-up, in this
The use of wet steam in an engine or turbine is
case the plant turbines exhaust at back pressures above
uneconomical besides involving some risk ; hence it is usual
atmospheric to supply steam for other purposes. Feed water
to endeavour to separate any water that may be present
is heated by bleeding steam to heaters as in a regenerative
from the steam before the latter enters the engine. This is
cycle from the main turbine, or by using exhaust steam
accomplished by the use of a steam separator. Thus the
from auxiliary-drive turbines, or by by-product steam from
function of a steam separator is to remove the entrained
processes. Feed water heating with steam at a lower pressure
water particles from the steam conveyed to the steam engine
than boiler pressure usually raises overall plant efficiency.
or turbine. It is installed as close to the steam engine as
possible on the main steam pipe from the boiler. 3.16.1. Feed Water Heaters
The feed water heaters may be classified as follows :
1. Open or contact heaters
C A
(i) Tray type (ii) Jet type.
2. Closed or surface heaters
Heated feed water enables steam generators to
produce more kg of steam and avoids severe thermal
stressing by cold water entering a hot drum. Preheating
feed water also causes scale-forming dissolved salts to
precipitate outside the boiler and removes dissolved O2 and
Water gauge CO2, which corrode boiler material.
B 3.16.1.1. Open heaters
(i) Tray type open heater. The construction of an
open heater employs a shell of rolled steel plates riveted or
welded along a longitudinal seam. Dished steel ends are
joined to the shell at two ends through riveting or welding.
In the tray type heater (Fig. 3.73), the upper half of the
D
shell contains two tray sections and the spray distributor,
while the lower half is mostly empty and serves as a storage
for heated water. Above the shell is placed a vent condenser.
A, C = Flanges D = Drain pipe Feed water after passing through the vent condenser flows
B = Baffles into the spray distributor from where it cascades over the
Fig. 3.72. Baffle plate steam separator.
116 POWER PLANT ENGINEERING
staggard trays. Exhaust steam from auxiliaries or low also the trays, is made of corrosion resistant material such
pressure steam from a suitable point in the turbine is as stainless steel.
passed into the heater, entering opposite the tray sections (ii) Jet type open heaters. In this type of
and flowing upward counter to the direction of water, deaerating contact heater spring loaded spray valves
through the heating section. The flow of two liquids through atomise the feed water coming from the vent condenser
the heater, thus, results in thorough mixing up so that and spray it upwards against a baffle. The low pressure
heat of steam is transferred to water, the steam itself also steam enters a conical steam jacket fitted in the upper part
being condensed. O2, CO2 and NH3 are also removed by of the shell, and is alowed to expand in the same direction
this type of heater. as the water spray, mixes with water, and the mixture falls
In addition to the heating of feed water, the contact down to the lower part of the shell which serves as a storage.
type heater is often constructed for deaerating action. The The non-condensing gases travel upwards as in the tray
only difference between the simple heater and a deaerating type heater and are passed on to the vent condenser. It is
open heater is in the addition of a section of air removing mainly used in marine where tray type of heaters do not
trays below the heating trays. After the water has been work well due to the pitching and rolling of the vessel. They
heated in the heating section, it is made to pass over the
can handle water containing scaling impurities and are
air separating trays which provide a complete separation
lighter in weight. These heaters do not work well at low
of air and water. Water then flows down while air and non-
pressures, specially at sub-atmospheric pressure.
condensable gases together with water vapour pass to the
top of the shell and from there to the vent condenser. The 3.16.1.2. Closed or Surface feed heaters
vent condenser is a small surface condenser of U-type. The
These heaters usually have shell and tube
vapour content is condensed here and drained to the air
construction and may be made horizontal and vertical. The
separating section while air and gases are vented to the
construction of a closed heater and a surface condenser
atmosphere. The interior of the shell of deaerating heat, as
are identical except that the heater is designed for higher
Vent Feed water temperatures and pressures and has greater strength than
Vent the condenser.
condenser Fig. 3.74 shows a closed feed water heater. It consists
of a shell (made of a steel plate of suitable thickness) which
has a welded longitudinal seam. To each end of the shell is
welded a steel flange for fitting the covers, and on the top
and bottom connections are provided for inlet of steam and
exit of condensate. A baffle plate is provided below the
Spray
steam inlet to spread the steam evenly over the tubes. The
pipe
water tubes (16 to 25 mm diameter) of admiralty brass or
Heating other suitable material, are stretched between two end
trays sheets of Muntz metal or soft steel, one of these being fixed
Steam
in and the other ‘floating’ to take up expansion strain in tubes.
Air
The floating tube sheet is covered with a head cover bolted
removing
trays on to it and prevents the leakage of water into space.
Vented The heater may have single pass or the water box
steam may be divided to give two-pass design. A pair of air pockets
outlet provided at the bottom of the shell permits the withdrawal
of air.
Over flow The flow of steam and water through the heater is
usually counter to each other. Low pressure heaters may
use steam under vacuum and high-pressure heaters at
pressures above 40 bar. Steam and water need not be at
the same pressure, and one pump may push water through
Feed water outlet several heaters in series. Water pressure may be as high
as 250 bar.
Fig. 3.73. Tray type open heater.
STEAM POWER PLANT 117
Feed water
outlet Condensate
Turbine Generator
Leakoff steam
to De-aerator
Boiler
Economiser
and
superheater
Evaporator Generator
Condenser air cooler
Oil
cooler
Air
off take Air
main evacuator
and
T Make up Condensate pump
condenser
S
ST
HPH IPH
DH
DC DC LPH
T T Boiler
feed Heater condensate
pump pump
3.17. PERFORMANCE OF BOILERS and saturated steam at 100°C. As per these standard
conditions 1 kg of water at 100°C necessitates 2257 kJ (539
3.17.1. Evaporative Capacity kcal in MKS units) to get converted to steam at 100°C.
Thus the equivalent evaporation may be defined
The evaporative capacity of a boiler may be expressed in
as the amount of water evaporated from water at 100°C to
terms of :
dry and saturated steam at 100°C.
(i) kg of steam/h
Consider a boiler generating ma kg of steam per hour
(ii) kg of steam/h/m2 of heating surface at a pressure p and temperature T.
(iii) kg of steam/kg of fuel fired. Let, h = Enthalpy of steam per kg under the
3.17.2. Equivalent Evaporation generating conditions, and
Generally the output or evaporative capacity of the boiler LM h = h + h ...... dry saturated steam at pressure p OP
is given as kg of water evaporated per hour but as different
f
f
fg
MM h = h +pressure
xh ...... wet steam with dryness fraction x at
fg
PP
boilers generate steam at different pressures and
temperatures (from feed water at different temperatures) MN h = h + h + c p(T – T ) ...... superheated steam at PQ
f fg p sup s
and as such have different amounts of heat ; the number
pressure p and temperature T sup
of kg of water evaporated per hour in no way provides the
exact means for comparison of the performance of the hf1 = Specific enthalpy of water at a given feed
boilers. Hence to compare the evaporative capacity or temperature.
performance of different boilers working under different
Then heat gained by the steam from the boiler per
conditions it becomes imperative to provide a common base
unit time
so that water be supposed to be evaporated under standard
conditions. The standard conditions adopted are : = ma (h – hf )
1
Temperature of feed water 100°C and converted into dry
STEAM POWER PLANT 119
The equivalent evaporation (me) from the definition (iii) The condition of heat absorbing surfaces.
is obtained as : (iv) Excess air fluctuations.
ma (h hf1 ) (v) Incomplete combustion and combustibles in the
ma (h hf1 )
me = = ...(3.19) refuse.
hfg 2257
(vi) Change in draught from the rated, due to
The evaporation rate of the boiler is also sometimes atmospheric conditions.
given in terms of kg of steam/kg of fuel. (vii) Humidity and temperature of the combustion
The presently accepted standard of expressing the air.
capacity of a boiler is in terms of the total heat added per 3.17.5. Heat Losses in a Boiler Plant
hour.
The following heat losses occur in a boiler plant :
3.17.3. Factor of Evaporation 1. Heat lost to flue gases.
It is defined as the ratio of heat received by 1 kg of water 2. Heat lost due to incomplete combustion.
under working conditions to that received by 1 kg of water 3. Heat lost due to unburnt fuel.
evaporated from and at 100°C. It is denoted by Fe. 4. Convection and radiation losses.
Factor of evaporation,
1. Heat lost to flue gases. The flue gases contain
h hf1 dry products of combustion as well as the steam generated
Fe = ...[3.19(a)] due to combustion of hydrogen in the fuel.
2257
Heat lost through dry flue gases, Qg :
3.17.4. Boiler Efficiency
Qg = mg cpg (Tg – Ta) ...(3.21)
‘Boiler efficiency’ is the ratio of heat actually utilised in
where, mg = Mass of gases formed per kg of coal,
generation of steam to the heat supplied by the fuel in the
same period. cpg = Specific heat of gases,
ma (h hf1 ) Tg = Temperature of the gases, and
i.e., Boiler efficiency = ...(3.20) Ta = Temperature of air entering the combustion
C
where, ma = Mass of water actually evaporated into steam chamber of boiler.
per kg of fuel at the working pressure, and Heat carried away by the steam in flue gases, Qs :
C = Calorific value of the fuel in kJ/kg.
Qs = ms1 ( hs1 – hf1 ) ...(3.22)
If the boiler, economiser, and superheater are
considered as a single unit, then the boiler efficiency is
where, ms1 = Mass of steam formed per kg of fuel due to
termed as overall efficiency of the boiler plant.
The following are the factors on which the boiler the combustion of H2 in the flue,
efficiency depends : hf1 = Enthalpy of water at boiler house
1. Fixed factors 2. Variable factors.
temperature, and
1. Fixed factors. These are :
(i) Boiler design. It includes the arrangement and hs1 = Enthalpy of steam at the gas temperature
effectiveness of the heating surfaces, the shape and volume and at a partial pressure of steam vapour in
of the furnace, the arrangement of flues, the arrangement the gas.
of steam and water circulation. This heat lost to flue gases can be reduced by passing
(ii) Heat recovery equipment. It includes the the flue gases through the economiser and air preheater.
economiser, superheater, air preheater and feed water
2. Heat lost due to incomplete combustion. The
heater.
combustion is said to be incomplete if the carbon burns to
(iii) Built in losses. It includes the heat transfer CO instead of CO2. One kg of carbon releases 10120 kJ of
properties of the settings and construction materials, flue
heat if it burns to CO, whereas, it can release 33800 kJ/kg
gas and ash heat losses.
if it burns to CO2.
(iv) Rated rate of firing, the furnace volume and
Heat loss due to incomplete combustion of 1 kg
heating surface.
of carbon = 33800 – 10120 = 23680 kJ.
(v) Properties and characteristics of fuel burnt.
If CO is present in the flue gases it indicates that
2. Variable factors. These are :
combustion of fuel is incomplete. If the percentages of CO
(i) Actual firing rate. and CO2 in flue gases by volume are known, then carbon
(ii) Fuel condition as it is fired. burnt to CO instead of CO2 per kg of fuel is given by
120 POWER PLANT ENGINEERING
At 45 bar and 350°C. From steam tables, Heat utilized by 1 kg of feed water in economiser :
hsup = 3068.4 kJ/kg hf1 = 1 × 4.18 × ( te2 – te1 )
hf1 (at 150°C) = 1 × 4.18 × (150 – 0)
= 1 × 4.18 × (115 – 32) = 346.9 kJ/kg
= 627 kJ/kg Heat utilized in boiler per kg of feed water :
Putting these values in eqn. (i), we get :
hboiler = (hf + xhfg) – hf1
5.4 (3068.4 627)
0.82 = At 14 bar pressure : From steam tables,
mf 28100
ts = 195C, hf = 830.1 kJ/kg,
5.4 (3068.4 627)
mf = hfg = 1957.7 kJ/kg
0.82 28100
hboiler = (830.1 + 0.96 × 1957.7) – 346.9
= 0.572 kg/kWh. (Ans.)
= 2362.6 kJ/kg
(ii) The cost of fuel (coal)/kWh = mf in tonnes/kWh
Heat utilized in superheater by 1 kg of feed water :
× cost/tonne
hsuperheater = (1 – x) hfg + cps (Tsup – Ts)
0.572 = (1 – 0.96) × 1957.7 + 2.3 (260 – 195)
= × 500 × 100
1000 = 78.3 + 149.5 = 227.8 kJ/kg.
= 28.6 paise/kWh. (Ans.) Also, mass of water evaporated/hour/kg of coal burnt
Example 3.6. The following data refer to a boiler plant
consisting of an economiser, a boiler and a superheater : 5940
= = 8.8 kg.
Mass of water evaporated per hour = 5940 kg, mass 675
of coal burnt per hour = 675 kg, L.C.V. of coal = 31600 (i) Percentage of heat utilized in economiser
kJ/kg, pressure of steam at boiler stop valve = 14 bar,
346.9
temperature of feed water entering the economiser = 32°C, = × 8.8 × 100 = 9.66%. (Ans.)
temperature of feed water leaving the economiser = 115°C, 31600
dryness fraction of steam leaving the boiler and entering Percentage of heat utilized in boiler
superheater is 0.96, temperature of steam leaving the
2362.6
superheater = 260°C, specific heat of superheater steam = = × 8.8 × 100 = 65.7%. (Ans.)
2.3. Determine : 31600
(i) Percentage of heat in coal utilized in economiser, Percentage of heat utilized in superheater
boiler and superheater. 227.8
(ii) Overall efficiency of boiler plant. = × 8.8 × 100 = 6.34%. (Ans.)
31600
Solution. Mass of water evaporated
(ii) Overall efficiency of boiler plant, overall :
= 5940 kg/h
Total heat absorbed in kg of water
Mass of coal burnt = 675 kg/h
Lower calorific value of coal = hf1 + hboiler + hsuperheater
= 31600 kJ/kg = 346.9 + 2362.6 + 227.8 = 2937.3 kJ/kg
Pressure of steam at boiler stop valve, Overall efficiency
p1 = 14 bar
Temperature of feed water entering the economiser, 8.8 2937.3
overall =
31600
te1 = 32°C
= 0.8179 or 81.79%. (Ans.)
Temperature of feed water leaving the economiser,
Example 3.7. A boiler produces 200 kg of dry and saturated
te2 = 115°C steam per hour at 10 bar and feed water is heated by an
Dryness fraction of steam entering superheater economiser to a temperature of 110°C. 225 kg of coal of a
= 0.96 calorific value of 30100 kJ/kg are fired per hour. If 10% of
coal remains unburnt, find the thermal efficiency of the
Temperature of steam leaving the superheater,
boiler and boiler and grate combined.
tsup = 260°C
Solution. Rate of production of steam
Specific heat of superheated steam,
cps = 2.3 kJ/kg K = 2000 kg/h
122 POWER PLANT ENGINEERING
Temperature of feed water = 85°C Heat usefully utilised in the boiler per hour
Water evaporated = 3000 kg per hour
= 3000(hsup – hf1 ) = 3000 (2947.1 – 355.3)
Coal fired = 410 kg per hour
= 777400 kJ.
Ash = 40 kg per hour
(ii) Efficiency of the boiler and furnace
Percentage of combustible in ash = 9.6%
combined
Moisture in coal = 4.5%
Heat usefully utilised in boiler per hour
Calorific value of dry coal/kg = 30500 kJ/kg. =
Heat actually supplied per hour
Determine : (i) The efficiency of the boiler plant
including superheater. 7775400
= = 0.658 or 65.8%. (Ans.)
(ii) The efficiency of the boiler and furnace combined. 11812253
Take specific heat of superheated steam = 2.1
kJ/kg K. 3.18. STEAM NOZZLES
Solution. At 13 bar : From steam tables,
ts = 191.6°C, hf = 814.7 kJ/kg, 3.18.1. Introduction
hfg = 1970.7 kJ/kg A steam nozzle may be defined as a passage of varying
h = hsup = hf + hfg + cps (Tsup – Ts) cross section, through which heat energy of steam is
converted to kinetic energy. Its major function is to produce
= 814.7 + 1970.7 + 2.1 × 77 = 2947.1 kJ/kg
steam jet with high velocity to drive steam turbines. A
Also, hf1 = 1 × 4.18 × (85 – 0) = 355.3 kJ/kg turbine nozzle performs two functions :
(i) It transforms a portion of energy of steam
Total heat supplied to produce 1 kg of steam
(obtained from steam generating unit) into kinetic energy.
= hsup – hf1 = 2947.1 – 355.3 (ii) In the impulse turbine it directs the steam jet of
high velocity against blades, which are free to move in order
= 2591.8 kJ/kg.
to convert kinetic energy into shaft work. In reaction
(i) Efficiency of boiler plant including turbines the nozzles which are free to move, discharge high
superheater velocity steam. The reactive force of the steam against the
ma (hsup hf1 ) nozzle produces motion and work is obtained.
=
C The cross-section of a nozzle at first tapers to a
LMDry coal = 410 – 410 4.5 OP smaller section (to allow for changes which occur due to
changes in velocity, specific volume and dryness fraction as
MM 100
PP
N 391.55 kg Q the steam expands) ; the smallest section being known as
throat, and then it diverges to a large diameter. The nozzle
3000 which converges to throat and diverges afterwards is known
( 2947.1 355.3) as convergent-divergent nozzle (Fig. 3.76). In convergent
= 391.55
30500 nozzle there is no divergence after the throat as shown in
= 0.651 or 65.1%. (Ans.) Fig. 3.77.
9.6 Convergent
Combustible in ash per hour = 40 × = 3.84 kg. part
100 Divergent
part
The combustible present in ash is practically
carbon and its value may be taken as 33860 kJ/kg.
Heat actually supplied per hour Entry Exit
= Heat of dry coal – heat of combustible in the
ash
= 391.55 × 30500 – 3.84 × 33860
= 11812253 kJ Throat
Fig. 3.76. Convergent-divergent nozzle.
124 POWER PLANT ENGINEERING
n
LM F p I OP 1
1
p v M1 G J
MN H p K PPQ
n
= 44.72 hd ...(3.25) = 2
1 1
n 1 1
STEAM POWER PLANT 125
L F I OP n 1
Fp I
2
1
F n 1IJ FG p IJ
n1
1
p v MM1 G p J – G
2 n
GH p JK
n 2
n or,
H n K HpK =0
MN H p K PPQ
n 2
= 1 1
2
n 1
n 1 1
1
Fp I F I
2
LM F p I OP
1 1/ n
n 1 p2
GH p JK GH JK
n 1 n
F n I
2
or, =
H n 1JK p v MM1 GH p JK
=2 G PP
n 2 p1
2 1
C2 1 1
N 1
Q Fp I 2n
FG n 1IJ FG p IJ
n
or, GH p JK2
=
H 2 K Hp K
2
FG n IJ p v R|S1 FG p IJ U|
n 1 1 1
C= 2
H n 1K | H p K
2
n
V|
Fp I FG IJ
1 1
F n 1IJ
n
2 n 1
T W
n
=G
1 p2 2
GH p JK
n1
H 2 K
2
...(3.30)
or,
1
or
p1
=
n1 H K
...(3.33)
If m is the mass of steam discharged in kg/s.
Hence the discharge through the nozzle will be the
AC maximum when critical pressure ratio, i.e.,
Then m= ...(3.31)
v2
FG IJ
n
Substituting the value of v2 from eqn. (3.29) in Throat pressure p 2 n 1
eqn. (3.31),we get : Inlet pressure
= 2 =
p1 n 1 H K
AC For saturated steam : n = 1.135
m=
FG p IJ 1/ n
FG IJ
1.135
1
v1
Hp K 2
p2
p1
=
2
H
1.135 1 K
1.135 1
LM F p I n1 OP
= FG
F n I 2 I
1.135
H 2.135 JK
A
H n 1JK p v MM1 GH p JK PP
n
2G
0.135
or m = 2 = 0.58
Fp I
v G J
1/ n 1 1
Hp K1
1
2
N 1
Q For superheated steam : n = 1.3
LM R|F p I F UO FG IJ
1.3
= FG
2 I
1.3
p I F p I |P
n1 p2
F n I
H 2.3 JK
2/ n 2/ n 2 1.3 1 0.3
F p I MGH p JK G J PP = 0
n
2G MMGH n 1JK G
d
PP
2 2 n1 n1
Hp K
1
d G J MN Q
=A
H n 1K v H n 1K
Hp K
2
1
1 1 1
N Q
126 POWER PLANT ENGINEERING
LMF 2 I OP FG n IJ p v FG n 1IJ
F n IJ p FG 2 IJ
n 1 2 n 1
2G 1 n 1
MMGH n 1JK
n 1 n 1
1P
= 2
H n 1K H n 1K
1 1
=A
H n 1K v H n 1K PQ
1
N F n IJ p v
2G
LMF 2 I OP
i.e., Cmax =
H n 1K 1 1 ...(3.34)
FG n IJ FG p IJ FG 2 IJ
n 1 1n
MMGH n 1JK PP
1 n 1 n 1
The above equation indicates that the velocity is also
=A 2
H n 1K H v K H n 1K 1
1
N Q dependent on the initial conditions of the steam.
3.18.4. Nozzle Efficiency
FG n IJ FG p IJ FG 2 IJ
n 1
LMF 2 I 1 OP When the steam flows through a nozzle the final velocity
MNGH n 1JK
n 1
1 of steam for a given pressure drop is reduced due to the
=A 2
H n 1K H v K H n 1K
1
1
PQ following reasons :
(i) The friction between the nozzle surface and
steam ;
FG n IJ FG p IJ FG 2 IJ FG n 1IJ
n1
n1
H n 1K H v K H n 1K H 2 K
1
=A 2 (ii) The internal friction of steam itself ; and
1
(iii) The shock losses.
Most of these frictional losses occur between the
F p I F 2 IJ
n1
nG J G
1 n1 throat and exit in convergent-divergent nozzle. These
i.e., mmax = A
H v K H n 1K
1
...[3.33 (a)]
frictional losses entail the following effects :
(i) The expansion is no more isentropic and enthalpy
From the above equation it is evident that the
maximum mass flow depends only on the initial condition drop is reduced ;
of the steam (p1, v1) and the throat area and is independent (ii) The final dryness friction of steam is increased
of the final pressure of steam i.e. at the exit of the nozzle. as the kinetic energy gets converted into heat due do friction
The addition of the divergent part of the nozzle after the and is absorbed by steam ;
throat does not affect the discharge of steam passing through
the nozzle but it only accelerates the steam leaving the nozzle. (iii) The specific volume of steam is increased as the
steam becomes more dry due to this frictional reheating.
It may be noted that the discharge through nozzle
increases as the pressure at the throat of the nozzle (p2) Fig. 3.78 represents on Mollier diagram the effect
decreases, when the supply pressure p1 is constant. But of friction on steam flow through a nozzle.
once the nozzle pressure p2 reaches the critical value [given The point 1 represents the initial condition of steam
by equation (3.33)], the discharge reaches a maximum and which enters the nozzle in a dry saturated state. If the
after that the throat pressure and mass flow remains
friction is neglected, the expansion of steam from entry to
constant irrespective of the pressure at the exit.
throat is represented by the vertical line 1-2 and that from
The velocity of steam at the throat of the nozzle when the throat to the exit by 2-3. Now if the friction were taken
the discharge is maximum is obtained by substituting the into account the heat drop would have been somewhat less
p2 than 1-3. Let this heat drop be 1-3. From 3 draw a
value of from eqn. (3.33) into eqn. (3.30).
p1 horizontal line which cuts the same pressure line on which
point 3 lies, at the point 2 which represents the final
LM R U|
n 1 OP condition of steam. It may be noted that dryness fraction
F n IJ p v M1 |SFG 2 IJ
n
PP
n
of steam is more at point 2 than at point 3. Hence the
Cmax = 2G
H n 1K MM |H n 1K
n 1
V| effect of friction is to improve the quality of steam. The value
PP
1 1
MN T W Q
of co-efficient ‘k’ in the equation for the velocity of expanding
steam is given by :
F n IJ p v FG1 2 IJ
2G
k=
Actual heat drop
=
1 3 h h3
= 1 .
=
H n 1K H n 1K
1 1 Isentropic heat drop 13 h1 h3
STEAM POWER PLANT 127
h
C2 2 C12
or h1 – h2 =
Superheat region 2
4
C2 2 C12
5 Nozzle efficiency = ...(3.36)
C32 C12
been maintained. Consequently, enthalpy drop is reduced than that for the equilibrium conditions which
and the condition of the final steam is improved. The gives the increase in the mass of steam
limiting condition of under-cooling at which condensation discharged.
commences and is assumed to restore conditions of normal (iv) The dryness fraction of steam is improved.
thermal equilibrium is called the “Wilson Line”.
The problems on supersaturated flow cannot be
h solved by Mollier chart unless Wilson line is drawn on it.
The velocity of steam at the end of expansion is found
by using the relation,
h1
1
LM F p I n1 OP
F n IJ p v
2G MM1 GH p JK
2
n
PP
C2 =
H n 1K
Superheat region
1 1
N Q
A 1
Fp I 1/n
GH p JK
2 B Wilson line 2
Specific volume, v2 = v1
3 1
Saturation line
Fp I
n 1
(x = 1)
GH p JK
4 n
2
h2 Apparent temperature, T2 = T1
4¢ 1
Decrease in heat drop
s m v2
and A2 = .
Increase in entropy C2
Example 3.10. Dry saturated steam at a pressure of
Fig. 3.79. Supersaturated flow of steam. 11 bar enters a convergent-divergent nozzle and leaves at a
It may be noted that when metastable conditions pressure of 2 bar. If the flow is adiabatic and frictionless,
prevail the h-s chart/diagram should not be used and the determine :
expansion must be considered to follow the law pv1.3 = C, (i) The exit velocity of steam.
i.e., with the index of expansion for superheated steam. Thus, (ii) Ratio of cross-section at exit and that at throat.
n p
LM F I OP n1 Assume the index of adiabatic expansion to be 1.135.
Solution. Refer to Fig. 3.80.
MM GH JK PP
n
Enthalpy drop = p1 v1 1 2
(n 1) p1 p1 = 11 bar ; p3 = 2 bar ; p2 = Throat
N Q pressure ; n = 1.135
FG 2 IJ
n1 n
The relationship, T2/T1 = ( p2 / p1) n may be used p n 1
r
ba
b quality of steam used per hour and the power developed.
11
.38
Solution. p1 = 9 bar, p3 = 1 bar, p2 = throat pressure,
p1 =
=6 Number of nozzles = 2
r
ba
2
p
2
FG 2 IJ
n
=
1
p2 n 1
3
h1 p
h2 2
We know that,
p1
=
H n 1K
Since the steam is dry and saturated, n = 1.135
Saturation line
FG IJ
1.135
(x = 1) p2 2 1.135 1
=
h3
x2 = 0.96 p1 H
1.135 1 K = 0.58
= 9.82 × 10–6 m2
= 44.72 300
Mass of steam used per sec.,
= 774.6 m/s. (Ans.)
x 3 vg
m 0.9 0.885
m A2 C2 9.82 106 424.2
Exit area, A3 = 3
= =
m =
C3 774.6 x2 vg2 0.96 0.361
= 0.001028 m = 0.012 kg/s
exit area 0.001028 m Energy supplied by the steam to the wheel per sec
Ratio of =
throat area 0.000638 m
C3 2
m 0.012 8162
= 1.62. (Ans.) = =
Example 3.11. The nozzles of a De laval steam turbine are 2 2
supplied with dry saturated steam at a pressure of 9 bar.
= 3995 W ~ 4 kW.
The pressure at the outlet is 1 bar. The turbine has two
130 POWER PLANT ENGINEERING
r
ba
r
ba
=9
.22
h (kJ/kg)
1
p
=5
r
ba
1
1
2
1 400°C
p
=
h1 h1 =
3
hd p 3250
2 hd
hd¢ h2 2¢ Saturation
line 2¢
h2 = r
3065 0 ba 2
h3 3¢
3 =2 bar
p1 0.9
h (kJ/kg K) =1
p2
Fig. 3.81
s (kJ/kg K)
Useful work = turbine × 4 = 0.35 × 4 = 1.44 kW.
Fig. 3.82
i.e., Power developed = 1.44 kW. (Ans.)
Example 3.12. An impulse turbine having a set of 16 Area at exit for one nozzle,
nozzles receives steam at 20 bar, 400°C. The pressure of m v2 260 0.235
steam at exit is 12 bar. If the total discharge is 260 kg/min A2 = =
C2 no. of nozzles 60 577 16
and nozzle efficiency is 90%, find the cross-sectional area of
the exit of each nozzle. If the steam has a velocity of 80 m/s = 1.1 × 10–4 m2. (Ans.)
at entry to the nozzles, find the percentage increase in Taking into account the initial velocity of steam as
discharge. 80 m/s, the velocity of steam at exit, C2 is calculated as
Solution. Set of nozzles = 16, p1 = 20 bar, 400°C follows :
Total discharge = 260 kg/min, C2 2 C12
= khd
nozzle = 90%. 2
i.e., 2
C2 = 2 khd + C12
Since the steam supplied to the nozzle is = 2 × 0.9 × 185 × 1000 + 802
superheated, the throat pressure is given by : = 339400
p2 C2 = 582.6 m/s
= 0.546 Percentage increase in velocity
p1
582.6 577
p2 = 20 × p1 = 20 × 0.546 = 10.9 bar = × 100 = 0.97%.
LM For superheated steam : n = 1.3 OP 577
This will result in 0.97% increase in discharge as
MM p F 2 I F 2 I n 1.3 PP specific volume will not be affected by velocity of approach.
1
PP Hence percentage increase in discharge =
0.97%. (Ans.)
MN = 0.546 PQ
3.19. STEAM TURBINES
Since the pressure is less than the exit pressure of
steam from nozzle, as such the nozzle is convergent type. 3.19.1. Introduction
From Mollier chart :
The steam turbine is a prime mover in which the potential
h1 = 3250 kJ/kg energy of the steam is transformed into kinetic energy, and
h2 = 3065 kJ/kg latter in its turn is transformed into the mechanical energy
hd = h1 – h2 = 3250 – 3065 = 185 kJ/kg. of rotation of the turbine shaft. The turbine shaft, directly
Velocity at exit neglecting initial velocity of steam, or with the help of a reduction gearing, is connected with
the driven mechanism. Depending on the type of the driven
C2 = 44.72 khd = 44.72 0.9 185
mechanism a steam turbine may be utilised in most diverse
= 577 m/s
STEAM POWER PLANT 131
fields of industry, for power generation and for transport. (iii) Turbines with by pass governing in which steam
Transformation of the potential energy of steam into the turbines besides being fed to the first stage is
mechanical energy of rotation of the shaft is brought about also directly fed to one, two or even three
by different means. intermediate stages of the turbine.
3.19.2. Classification of Steam Turbines 5. According to heat drop process :
(i) Condensing turbines with generators ; in these
There are several ways in which the steam turbines may
turbines steam at a pressure less than
be classified. The most important and common division
atmospheric is directed to a condenser ; besides,
being with respect to the action of the steam, as :
steam is also extracted from intermediate stages
(a) Impulse.
for feed water heating, the number of such
(b) Reaction. extractions usually being from 2-3 to as much
(c) Combination of impulse and reaction. 8-9. The latent heat of exhaust steam during the
Other classification are : process of condensation is completely lost in
these turbines.
1. According to the number of pressure stages :
(ii) Condensing turbines with one or two
(i) Single-stage turbines with one or more velocity intermediate stage extractions at specific
stages usually of small-power capacities ; these pressures for industrial and heating purposes.
turbines are mostly used for driving centrifugal (iii) Back pressure turbines, the exhaust steam from
compressors, blowers and other similar which is utilised for industrial or heating
machinery. purposes ; to this type of turbines can also be
(ii) Multi-stage impulse and reaction turbines ; they added (in a relative sense) turbines with
are made in a wide range of power capacities deteriorated vacuum, the exhaust steam of which
varying from small to large. may be used for heating and process purposes.
2. According to the direction of steam flow : (iv) Topping turbines ; these turbines are also of the
back pressure type with the difference that the
(i) Axial turbines in which steam flows in a direction
exhaust steam from these turbines is further
parallel to the axis of the turbine.
utilised in medium and low-pressure condensing
(ii) Radial turbines in which steam flows in a turbines. These turbines, in general, operate at
direction perpendicular to the axis of the high initial conditions of steam pressure and
turbine ; one or more low-pressure stages in such temperature, and are mostly used during
turbines are made axial. extension of power station capacities, with a view
3. According to the number of cylinders : to obtain better efficiencies.
(v) Back pressure turbines with steam extraction
(i) Single-cylinder turbines.
from intermediate stages at specific pressure ;
(ii) Double-cylinder turbines. turbines of this type are meant for supplying the
(iii) Three-cylinder turbines. consumer with steam of various pressures and
(iv) Four-cylinder turbines. temperature conditions.
Multi-cylinder turbines which have their rotors (vi) Low pressure turbines in which the exhaust
mounted on one and the same shaft and coupled to a single steam from reciprocating steam engines, power
generator are known as single shaft turbines ; turbines with hammers, etc., is utilised for power generation
separate rotor shafts for each cylinder placed parallel to purposes.
each other are known as multiaxial turbines. (vii) Mixed pressure turbines with two or three
pressure stages, with supply of exhaust steam
4. According to the method of governing :
to its intermediate stages.
(i) Turbines with throttle governing in which fresh
steam enters through one or more (depending 6. According to steam conditions at inlet to
on the power developed) simultaneously turbine :
operated throttle valves. (i) Low pressure turbines, using steam at a pressure
(ii) Turbines with nozzle governing in which fresh of 1.2 to 2 ata.
steam enters through two or more consecutively (ii) Medium pressure turbines, using steam at
opening regulators. pressure of up to 40 ata.
132 POWER PLANT ENGINEERING
(iii) High pressure turbines, utilising steam at The main difference between these turbines lies in
pressures above 40 ata. the way in which the steam is expanded while it moves
(iv) Turbines of very high pressures, utilising steam through them. In the former type steam expands in the
at pressures of 170 ata and higher and nozzles and its pressure does not alter as it moves over the
temperatures of 550°C and higher. blades while in the latter type the steam expands
(v) Turbines of supercritical pressures, using steam continuously as it passes over the blades and thus there is
at pressures of 225 ata and above. gradual fall in the pressure during expansion.
7. According to their usage in industry :
1. Simple impulse turbine :
(i) Stationary turbines with constant speed of
rotation primarily used for driving alternators. Fig. 3.83 shows a simple impulse turbine
(ii) Stationary steam turbines with variable speed diagrammatically. The top portion of the figure exhibits a
meant for driving turbo-blowers, air circulators, longitudinal section through the upper half of the turbine,
pumps, etc.
Boiler
(iii) Non-stationary turbines with variable speed ; steam
turbines of this type are usually employed in Exhaust
steamers, ships and railway locomotives.
Turbine blade
3.19.3. Advantages of Steam Turbine over the Steam
Engines Turbine wheel
Lost velocity
expense of slight reduction in overall efficiency.
Condenser
3.19.4. Description of Common Types of Turbines pressure
The common types of steam turbines are :
1. Simple Impulse turbine.
2. Reaction turbine. Fig. 3.83. Simple impulse turbine.
STEAM POWER PLANT 133
the middle portion shows one set of nozzles which is 2. Reaction turbine :
followed by a ring of moving blades, while lower part of the In this type of turbine, there is a gradual pressure
diagram indicates approximately changes in pressure and drop which takes place continuously over the fixed and
velocity during the flow of steam through the turbine. This moving blades. The function of the fixed blades is (the same
turbine is called ‘simple’ impulse turbine since the as the nozzle) that they alter the direction of the steam as
expansion of the steam takes place in one set of the nozzles. well as allow it to expand to a larger velocity. As the steam
passes over the moving blades its kinetic energy (obtained
As the steam flows through the nozzle its pressure
due to fall in pressure) is absorbed by them. Fig. 3.84 shows
falls from steam chest pressure to condenser pressure (or a multi-stage reaction turbine. The changes in pressure
atmospheric pressure if the turbine is non-condensing). Due and velocity are also shown therein.
to this relatively higher ratio of expansion of steam in the
As the volume of steam increases at lower pressures
nozzles the steam leaves the nozzle with a very high therefore, the diameter of the turbine must increase after
velocity. Refer to Fig. 3.83, it is evident that the velocity of each group of blade rings. It may be noted that in this turbine
the steam leaving the moving blades is a large portion of since the pressure drop per stage is small, therefore, the
the maximum velocity of the steam when leaving the nozzle. number of stages required is much higher than an impulse
The loss of energy due to this higher exit velocity is turbine of the same capacity.
commonly the “carry over loss” or “leaving loss”.
3.19.5. Methods of Reducing Wheel or Rotor Speed
The principal example of this turbine is the well
known “De laval turbine” and in this turbine the ‘exit As already discussed under the heading ‘simple impulse
velocity’ or ‘leaving velocity’ or ‘lost velocity’ may amount turbine’ that if the steam is expanded from the boiler
to 3.3 per cent of the nozzle outlet velocity. Also since all pressure to condenser pressure in one stage the speed of
the kinetic energy is to be absorbed by one ring of the the rotor becomes tremendously high which crops up
moving blades only, the velocity of wheel is too high (varying practical complicacies. There are several methods of
from 25,000 to 30,000 r.p.m.). This wheel or rotor speed reducing this speed to lower value ; all these methods utilise
however, can be reduced by different methods (discussed a multiple system of rotor in series, keyed on a common
in the Art. 3.19.5). shaft and the steam pressure of jet velocity is absorbed in
Casing
stages as the steam flows over the blades. This is known
as ‘compounding’. The different methods of compounding
are :
Boiler
steam 1. Velocity compounding.
Shaft
2. Pressure compounding.
3. Pressure velocity compounding.
4. Reaction turbine.
1. Velocity compounding :
Steam Steam
in out Steam is expanded through a stationary nozzle from
the boiler or inlet pressure to condenser pressure. So the
pressure in the nozzle drops, the kinetic energy of the steam
F M F M F M F M
increases due to increase in velocity. A portion of this
available energy is absorbed by a row of moving blades.
M = Moving blades The steam (whose velocity has decreased while moving over
F = Fixed blades
the moving blades) then flows through the second row of
blades which are fixed. The function of these fixed blades
Boiler pressure
Lost velocity done on them and steam leaves the turbine with a low
Condenser velocity. Fig. 3.85 shows a cut away section of such a stage
pressure and changes in pressure and velocity as the steam passes
through the nozzle, fixed and moving blades.
Moving blades
Fixed blades
Lost velocity each stage is also compounded. The rings of nozzles are
fixed at the beginning of each stage and pressure remains
Condenser constant during each stage. The changes in pressure and
pressure velocity are shown in Fig. 3.87.
Fig. 3.85. Velocity compounding.
Moving blades
Moving blades
Moving blades
Moving blades
Fixed nozzles
Fixed nozzles
Fixed blades
Fixed blades
Though this method has the advantage that the
initial cost is low due to lesser number of stages yet its
efficiency is low.
2. Pressure compounding :
Fig. 3.86 shows rings of fixed nozzles incorporated
between the rings of moving blades. The steam at boiler
pressure enters the first set of nozzles and expands
partially. The kinetic energy of the steam thus obtained is Steam Steam
in out
Stages
1 2 3
Steam
out
Boiler pressure
Initial steam
Steam
velocity
in Lost velocity
Condenser
pressure
Nozzles
Nozzles
Nozzles
Blades
Blades
Blades
Moore turbine.
velocity
Lost velocity
Exhaust 4. Reaction turbine:
pressure It has been discussed in Article 3.19.4.
1. Pressure drop Only in nozzles and not in moving In fixed blades (nozzles) as well as in moving blades.
blades.
2. Area of blade channels Constant. Varying (converging type).
3. Blades Profile type. Aerofoil type.
4. Admission of steam Not all round or complete. All round or complete.
5. Nozzles/fixed blades Diaphram contains the nozzle. Fixed blades similar to moving blades attached to the
casing serve as nozzles and guide the steam.
6. Power Not much power can be developed. Much power can be developed.
7. Space Requires less space for same power. Requires more space for same power.
8. Efficiency Low. High.
9. Suitability Suitable for small power require- Suitable for medium and higher power requirements.
ments.
10. Blade manufacture Not difficult. Difficult.
glides over the blade without any shock and discharges at s (Cw Cw ) Cbl
Power per wheel = m 1 0
a relative velocity of Cr0 at an angle with the tangent of
m sCwCbl
the blades. The relative velocity at the inlet ( Cr ) is the = kW ...(3.40)
1 1000
same as the relative velocity at the outlet ( Cr0 ) if there is (∵ Cw Cw1 Cw0 )
no frictional loss at the blade. The absolute velocity (C0) of Blade or diagram efficiency
leaving steam make an angle to the tangent at the wheel. Work done on the blade
=
To have convenience in solving the problems on Energy supplied to the blade
turbines it is a common practice to combine the two vector m s (Cw Cw ) . Cbl
1 0
velocity diagrams on a common base which represents the =
m C12
blade velocity (Cbl) as shown in Fig. 3.89. This diagram
has been obtained by superimposing the inlet velocity 2 Cbl (Cw1 Cw0 )
= ...(3.41)
diagram on the outlet diagram in order that the blade C12
velocity lines Cbl coincide. If h1 and h2 be the total heats before and after
expansion through the nozzles, then (h1 – h2) is the heat
drop through a stage of fixed blades ring and moving blades
ring.
Stage efficiency,
Work done on blade per kg of steam
stage =
Total energy supplied per kg of steam
C12
=
2 (h1 h2 )
Fig. 3.89
Also,stage = Blade efficiency × nozzle efficiency
3.19.7.2. Work done on the blade 2 Cbl (Cw1 Cw0 ) C12
The work done on the blade may be found out from the = ×
C12 2 (h1 h2 )
change of momentum of the steam jet during its flow over
the blade. As earlier discussed, it is only the velocity of Cbl (Cw1 Cw0 )
whirl which performs work on the blade since it acts in its =
(blade) direction of motion. (h1 h2 )
From Newton’s second law of motion, The axial thrust on the wheel is due to difference
between the velocities of flow at entrance and outlet.
Force (tangential) on the wheel
Axial force on the wheel
= Mass of steam × acceleration = Mass of steam × axial acceleration
= Mass of steam/sec. × change of velocity s (Cf Cf )
= m 1 0
...(3.43)
s (Cw Cw )
= m ...(3.39)
1 0
The axial force on the wheel must be balanced or
The value of Cw0 is actually negative as the steam must be taken by a thrust bearing.
is discharged in the opposite direction to the blade motion, Energy converted to heat by blade friction
therefore, due consideration should be given to the fact that = Loss of kinetic energy during flow over
the values of Cw1 and Cw0 are to be added while doing the blades
solution of the problem. s (Cr 2 Cr 2 )
= m ...(3.44)
1 0
Work done on blades/sec.
3.19.7.3. Blade velocity coefficient
= Force × distance travelled/sec.
In an impulse turbine, if friction is neglected the relative
s (Cw Cw ) Cbl
= m velocity will remain unaltered as it passes over blades. In
1 0
STEAM POWER PLANT 137
M Cbl
L Q
P
q f a b = 90°
Cr1 2
Cf1 C0 C0 = Cf0 cos a
C1 Cr0
S N
Fig. 3.90
Since the discharge is axial,
= 90°,
C0 = Cf0 and Cw0 = 0.
The variations of bl or work developed per kg of
Cbl
steam with is shown in Fig. 3.91. This figure shows
C1 Cbl
that : 0 cos a 1 C1
2
Cbl
(i) When = 0, the work done becomes zero as
C1 Fig. 3.91
the distance travelled by the blade (Cbl) is zero, even
through the torque on the blade is maximum. When the high pressure steam is expanded from
the boiler pressure to condenser pressure in a single stage
(ii) The maximum efficiency is cos2 and maximum
of nozzle, the absolute velocity of steam becomes maximum
Cbl and blade velocity also becomes tremendously high. In such
work done per kg of steam is 2C2bl when = cos /2.
C1 a case, a velocity compounded stage is used to give lower
Cbl blade speed ratio and better utilization of the kinetic energy
(iii) When = 1, the work done is zero as the of the steam. The arrangement of velocity compounding has
C1
torque acting on the blade becomes zero even though the already been dealt with.
distance travelled by the blade is maximum.
Cw 1 Cw 0
Cbl
M L
P Q
Cr1
Cf1
C1 C0 Cf 0
Cr 0
S
Cw1
P M Cbl L, Q N
= 90°
Cf1 Cr1 C0 = Cf0
Cr0
C1 = C0
N
S
LM = LM
Fig. 3.92
STEAM POWER PLANT 139
Fig. 3.92 shows the velocity diagrams for the first = 4Cbl (C1 cos – 2Cbl) ...(3.53)
and second row of moving blades of velocity compounded The blade efficiency for two stage impulse turbine
unit. The speed and angles are such that the final absolute is given by
velocity of the steam leaving the second row is axial. With Wt 2
this arrangement, the K.E. carried by the steam is bl = = 4Cbl [C1 cos 1 – 2Cbl] ×
C12 C12
minimum, therefore, efficiency becomes maximum.
2
The velocity of blades (Cbl) is same for both the rows
since they are mounted on the same shaft. 8Cbl
= (C1 cos – 2Cbl)
Consider first row of moving blades C12
Work done per kg of steam, Cbl F C I
W1 = Cbl (Cw1 Cw0 )
=8
C1
GH
cos 2 . bl
C1
JK
= 8 (cos – 2) ...(3.54)
= Cbl [Cr1 cos Cr0 cos ]
C
If there is no friction loss and symmetrical blading where, (velocity ratio) = bl .
C1
is used, then: The blade efficiency for two stage turbine will be
Cr1 = Cr0 and = dbl
maximum when =0
W1 = Cbl × 2 Cr cos = 2Cbl(C1 cos – Cbl) d
1
...(3.50) d
[8 cos – 162] = 0
The magnitude of absolute velocity of steam leaving d
the first row and entering into the second row of moving 8 cos – 32 = 0
blades is same and its direction only is changed.
C1 = C0 cos
From which, = ...(3.55)
Consider second row of moving blades : 4
Work done per kg, Substituting this value in eqn. (3.54), we get
cos LM cos OP
W2 = Cbl · C w as C
1 w0
(bl)max = 8 ·
4 N
cos 2
4
= cos2
Q
= 0 because discharge is axial and = 90° ...(3.56)
The maximum work done per kg of steam is obtained
Alternately, W2 = Cbl ⎡Cr1 cos Cr0 cos ⎤ by substituting the value of
⎣⎢ ⎦⎥
For symmetrical blades = Cbl cos
= =
and, if there is no friction loss, then C1 4
4Cbl
Cr1 = Cr0 or, C1 = in the eqn. (3.53).
cos
W2 = 2Cbl Cr1 cos FG 4C . cos 2C IJ
bl
= 2Cbl (C1 cos – Cbl) ...(3.51)
(Wb)max = 4Cbl
H cos K bl
As the number of rows increases, the utility of last 3.19.8.1. Velocity diagram for reaction turbine blade
row decreases. In practice, more than two rows are hardly Fig. 3.94 shows the velocity diagram for reaction turbine
preferred. blade. In case of an impulse turbine blade the relative
3.19.7.5. Advantages of velocity-compounded im- velocity of steam either remains constant as the steam
pulse turbine glides over the blades or is reduced slightly due to friction.
In reaction turbine blades, the steam continuously expands
1. Owing to relatively large heat drop, a velocity-
at it flows over the blades. The effect of the continuous
compounded impulse turbine requires a
expansion of steam during the flow over the blade is to
comparatively small number of stages.
increase the relative velocity of steam.
hbl
Cw1 C w0
M Cbl L
P a Q
q f b
Cr1
C0 Cf
Single stage Cf1 0
C1 Cr0
N
S
Two stage
Fig. 3.94. Velocity diagram for reaction turbine blade.
Three stage
Cr0 Cr1 for reaction turbine blade.
( Cr Cr for impulse turbine blade).
0 1
=
Cf LM (cot 1) (cot 1) OP
2 2
= Cbl[C1 cos + ( Cr0 cos – Cbl)]
2Cbl MN cot cot PQ = and Cr0 = Cr1 as per the assumptions.
=
Cf LM cot cot OP
2 2
as,
Total energy supplied to the stage, Substituting the value of from eqn. (3.69) into the
2 2 eqn. (3.68), the value of maximum efficiency is given by,
C12 Cr0 Cr1
h = + 2
2 2 (bl)max. = 2 –
as Cr0 = C1 for symmetrical triangles. 1 2 cos cos2
2
F 1 I = 2 cos
2
GH J 1 cos
2 2
C 2 C1 Cr1 = 2 1
h = 1
2 2 1 cos2 K 2
Cr1 2 2 cos2
= C12 ...(3.66) Hence, (bl)max. = ...(3.70)
2 1 cos2
Considering the LMS (Fig. 3.94) FC I
Cr1 2 = C12 Cbl 2
– 2C1 · Cbl · cos
The variation of bl with blade speed ratio GH C JK
bl
1
for the reaction stage is shown in Fig. 3.97.
2
Substituting this value of Cr1 is equation (3.66).
hbl
Total energy supplied to the stage
h = C12 – ( C12 Cbl 2 – 2C1 · Cbl · cos )/2
C2 LM
2Cbl C F I OP2 1 + cos a
2
= 1 1 . cos bl
MN GH JK P
2 C1 C1
Q
C12
=[1 2 cos 2 ] ...(3.67)
2
The blade efficiency of the reaction turbine is given
by,
W
bl =
h
Substituting the value of W and h from equations
(3.65) and (3.67),
C12 [ 2 cos 2 ]
bl = Cbl
C12
(1 2 cos 2 ) C1
2
2( 2 cos 2 ) Fig. 3.97
=
(1 2 cos 2 ) 3.19.9. Turbine Efficiencies
2( 2 cos ) 1. Blade or diagram efficiency (bl). It is the ratio
=
(1 2 cos 2 ) of work done on the blade per second to the energy entering
the blade per second.
2(1 2 cos 2 ) 2
= 2. Stage efficiency (stage). The stage efficiency
(1 2 cos 2 )
covers all the losses in the nozzles, blades, diaphragms and
2 discs that are associated with that stage.
=2– ...(3.68)
1 2 cos 2 Network done on shaft per stage
The bl becomes maximum when the value of per kg of steam flowing
(1 + 2 cos – 2) becomes maximum. stage =
Adiabatic heat drop per stage
The required equation is
Network done on blades
d
(1 + 2 cos – 2) = 0 Disc friction and windage
d = .
2 cos – 2 = 0 Adiabatic heat drop per stage
= cos ...(3.69)
STEAM POWER PLANT 143
3. Internal efficiency (internal). This is equivalent point during expansion in nozzles is shown by (1-3) which
to the stage efficiency when applied to the whole turbine, takes into account the effect of ‘nozzles losses’.
and is defined as : Then, s (h1 – h2) kW
A.P. = m ...(3.71)
Heat coverted into useful work After expansion in the nozzle the steam enters the
= .
Total adiabatic heat drop blades where the R.P. is developed. Due to blade friction
4. Overall or turbine efficiency (overall). This the steam is somewhat reheated and this reheating is
efficiency covers internal and external losses ; for example, shown by (3-4) along the constant pressure p2 line just for
bearings and steam friction, leakage, radiation etc. convenience. But in actual practice though the pressure at
outlet of the blade is equal to that at the inlet, the pressure
Work delivered at the turbine coupling in the blade channels is not constant. However, with this
in heat units per kg of steam simplification ;
overall = .
Total adiabatic heat drop
h (Enthalpy)
.
5. Net efficiency or efficiency ratio (net). It is
the ratio
Brake thermal efficiency
Thermal efficiency on the Rankine cycle 1
Also the actual thermal efficiency
Heat converted into useful p1
work per kg of steam
= .
Total heat in steam at stop valve
5
Water heat in exhaust 4
Again, Rankine efficiency 3
2
Adiabatic heat drop
= . p2
Total heat in steam at stop valve
Water heat in exhaust
Heat converted into useful work s (Entropy)
net = .
Total adiabatic heat drop
Fig. 3.98
Hence net = overall.
It is the overall or net efficiency that is meant when s (h1 – h4) kW
R.P. = m ...[3.71 (a)]
the efficiency of a turbine is spoken of without qualification. 4-5 shows the further reheating due to friction and
3.19.10. Types of Power in Steam Turbine Practice blade windage and these losses are given as
In steam turbine performance the following types of power s (h5 – h4) kW
(P)w.f. = m ...[3.71 (b)]
are generally used : Now points 1 and 5 are the initial and final stage
1. Adiabatic power (A.P.). It is the power based points respectively for a single stage impulse turbine. It,
on the total internal steam flow and adiabatic heat drop. therefore, follows that
2. Shaft power (S.P.). It is the actual power
s (h1 – h5) kW.
S.P. = m ...[3.71 (c)]
transmitted by the turbine.
3. Rim power (R.P.). It is the power developed at 3.19.11. Energy Losses in Steam Turbines
the rim. It is also called blade power.
The increase in heat energy required for doing mechanical
Power losses are usually expressed as follows :
work in actual practice as compared to the theoretical value,
(i) (P)D = Power lost in overcoming disc friction.
in which the process of expansion takes place strictly
(ii) (P)bw = Power lost in blade windage losses. according to the adiabatic process, is termed as energy loss
Let us consider the case, of an impulse turbine. Let in a steam turbine.
m s be the total internal steam flow in kg/s.
The losses which appear in an actual turbine may
Refer to Fig. 3.98. The line (1-2) represents the be divided into two following groups :
adiabatic or isentropic expansion of steam in the nozzle 1. Internal losses. Losses directly connected with
from pressure p1 to p2. But the actual path of the stage
the steam conditions while in its flow through the turbine
144 POWER PLANT ENGINEERING
are called internal losses. They may be further classified As the steam turbine gains speed the valve B closes to
as : throttle the steam and reduces the supply to the nozzle.
(i) Losses in regulating valves. For a turbine governed by throttling the relationship
(ii) Losses in nozzles (guide blades). between steam consumption and load is given by the well
(iii) Losses in moving blades : known Willan’s line as shown in Fig. 3.99 (b). Several tests
have shown that when a turbine is governed by throttling,
(a) losses due to trailing edge wake ;
the Willan’s line is straight. It is expressed as :
(b) impingement losses ;
(c) losses due to leakage of steam through the ms = KM + ms0 ...(3.72)
angular space ; s = Steam consumption in kg/h at any load M,
where, m
(d) frictional losses ; ms0 = Steam consumption in kg/h at no load,
(e) losses due to turning of the steam jet in the
blades ; ms1 = Steam consumption in kg/h at full load,
(f) losses due to shrouding. M = Any other load in kW,
(iv) Leaving velocity losses (exit velocity). M1 = Full load in kW, and
(v) Losses due to friction of disc carrying the blades K = Constant.
and windage losses.
Oil supply from
(vi) Losses due to clearance between the rotor and servomotor
guide blade discs.
Hand wheel
(vii) Losses due to wetness of steam.
(viii) Losses in exhaust piping etc.
2. External losses. Losses which do not influence A
the steam conditions. They may be further classified as :
(i) Mechanical losses.
(ii) Losses due to leakage of steam from the
To nozzles
labyrinth gland seals.
3.19.12. Steam Turbine Governing and Control
B
The objective of governing is to keep the turbine speed fairly
constant irrespective of load.
The principal methods of steam turbine governing
Steam inlet
are as follows : A, B = Valves
(a)
1. Throttle governing
2. Nozzle governing
3. By-pass governing
consumption, ms
1. Throttle governing ms
Throttle governing is the most widely used M
particularly on small turbines, because its initial cost is
ms
less and the mechanism is simple. The object of throttle
governing is to throttle the steam, whenever, there is a K
mso
reduction of load compared to economic or design load for
maintaining speed and vice versa. Load M (kW)
Fig. 3.99 (a) shows a simple throttle arrangement. (b)
To start the turbine for full load running valve A is opened.
The operation of double beat valve B is carried out by an Fig. 3.99. Throttle governing.
oil servomotor which is controlled by a centrifugal governor.
STEAM POWER PLANT 145
ms0 varies from about 0.1 to 0.14 times the full load larger units which have an impulse stage followed by an
consumption. The eqns. (3.72) can also be written as : impulse-reaction turbine. In pressure compounded impulse
turbines, there will be some drop in pressure at entry to
ms ms0
=K+ second stage when some of the first stage nozzles are cut
M M out.
ms
where, is called the steam consumption per kWh.
M
2. Nozzle governing
The efficiency of a steam turbine is considerably
reduced if throttle governing is carried out at low loads. An
alternative, and more efficient form of governing is by N1
means of nozzle control. Fig. 3.100 shows a diagrammatic
arrangement of typical nozzle control governing. In this V3 V2 V1
N2
method of governing, the nozzles are grouped together 3 to N3
5 or more groups and supply of steam to each group is
controlled by regulating valves. Under full load conditions
the valves remain fully open.
When the load on the turbine becomes more or less
than the design value, the supply of steam to a group of N1, N2, N3 = Groups of nozzles
nozzles may be varied accordingly so as to restore the V1, V2, V3 = Valves Steam inlet
original speed.
Fig. 3.100. Nozzle governing.
Nozzle control can only be applied to the first stage
of a turbine. It is suitable for simple impulse turbine and
3. By-pass governing
second valve to a lower stage in the turbine. When by-pass
The steam turbines which are designed to work at valve operates it is under the control of the turbine
economic load it is desirable to have full admission of steam governor. The secondary and tertiary supplies of steam in
in the high pressure stages. At the maximum load, which the lower stages increase the work output in these stages,
is greater than the economic load, the additional steam but there is a loss in efficiency and a curving of the Willian’s
required could not pass through the first stage since line.
additional nozzles are not available. By-pass regulation
In reaction turbines, because of the pressure drop
allows for this in a turbine which is throttle governed, by
required in the moving blades, nozzles control governing is
means of a second by-pass valve in the first stage nozzle
not possible, and throttle governing plus by-pass governing,
(Fig. 3.101). This valve opens when throttle valve has
is used.
opened a definite amount. Steam is by-passed through the
146 POWER PLANT ENGINEERING
By-pass valve pipe. This pipe leads to process plant or other turbine. The
By-pass steam back pressure turbine may be used in cases where the
To lower power generated (by expanding steam) from economical
stages initial pressure down to the heating pressure is equal to,
or greater than, the power requirements. The steam
Rotor
Rotor
Rotor
most cases it is not suitable for process work due to the
following reasons :
Shaft (i) It is impossible to control its temperature, and
(ii) Rate of the heat transfer from superheated
Throttle steam to the heating surface is lower than that of saturated
valve
steam. Consequently a desuperheater is invariably used.
To enhance the power capacity of the existing installation,
a high pressure boiler and a back-pressure turbine are
added to it. This added high pressure boiler supplies steam
to the back pressure turbine which exhaust into the old
Fig. 3.101. By-pass governing. low pressure turbine.
S N
1000
Solution. Mean diameter of the blades, D = 1.05 m
Speed of the turbine, N = 3000 r.p.m. 10 390 164.5
=
Nozzle angle, = 18° 1000
Ratio of blade speed to steam speed, = 641.55 kW. (Ans.)
= 0.42 (v) Blading efficiency
Cr1 2 Cbl (Cw1 Cw0 ) 2 164.5 390
Ratio, = 0.84 bl = =
Cr0 C12 3922
Outlet blade angle, = – 3° = 83.5%. (Ans.)
Steam flow rate, s = 10 kg/s
m Example 3.15. In a stage of impulse reaction turbine
DN 1.05 3000 provided with single row wheel, the mean diameter of the
Blade speed, Cbl = blades in 1 m. It runs at 3000 r.p.m. The steam issues from
60 60
the nozzle at a velocity of 350 m/s and the nozzle angle is
= 164.5 m/s
20°. The rotor blades are equiangular. The blade friction
Cbl factor is 0.86. Determine the power developed if the axial
But, = = 0.42 (given)
C1 thrust on the end bearing of a rotor is 118 N.
Cbl 164.5 Solution. Mean diameter of the blades,
C1 = = 392 m/s
0.42 0.42 D=1m
With the data, C1 = 392 m/s ; Speed of the turbine, N = 3000 r.p.m.
= 18°, complete LMS Velocity of steam issuing from the nozzle,
= 30° (on measurement) C1 = 350 m/s
= 30° – 3 = 27° Nozzle angle, = 20°
Now complete the LMN by taking Blade angles, =
= 27° and Cr = 0.84 Cr . Blade friction factor, K = 0.86
0 1
= 3900 N. (Ans.)
Cw = 390 m/s
Cw 1 Cw 0
M Cbl = 164.5 m/s L
P
30° q f 27° 18° a Q
b
Cr1 Cf0
Cf1 C0
C r0
C1
N
S
Fig. 3.106
(ii) Axial thrust Fig. 3.107
= m s (Cf Cf ) = 10 (120 – 95) — With the data, Cbl = 157 m/s, C1 = 350 m/s,
1 0
= 250 N. (Ans.) = 20° draw the LMS (Fig. 3.107).
(iii) Resultant thrust By measurement, = 35°
= (3900)2 ( 250)2 = 3908 N. (Ans.)
STEAM POWER PLANT 149
Since the blades are equiangular, and the leaving angles of blades are respectively, first-
= = 35° moving 30°, fixed 20° ; second-moving 30°. The velocity of
steam leaving the nozzle is 540 m/s. The friction loss in
— Now with = 35° and Cr0 = 0.86 Cr , each blade row is 10% of the relative velocity. Steam leaves
1
complete the LMN. the second row of moving blades axially.
On measurement ; Cf1 = 122 m/s, Cf0 = 102.5 m/s Find : (i) Blade velocity
s (Cf Cf ) = 118
Also, axial thrust m (ii) Blade efficiency
1 0
(iii) Specific steam consumption.
118 118
s =
m = Solution. Refer to Fig. 3.108.
C f1 C f0 (120 102.5)
Nozzle angle, = 15° ; = 20°
= 6.74 kg/s
Further in this case, = 90°
Cw = Cw1 Cw0 Cw1 ( Cw0 ) = 320 m/s [Since the steam leaves the blades axially]
s (Cw Cw ) Cbl
m Velocity of steam leaving the nozzle, C1 = 540 m/s
1 0
P= kW
1000 Cr0
= 0.9
6.74 320 157 Cr1
=
1000 C1
= 338.6 kW. (Ans.) = 0.9
C0
☞ Example 3.16. The first stage of an impulse turbine
Cr0
is compounded for velocity and has two rows of moving = 0.9
Cr1
blades and one ring of fixed blades. The nozzle angle is 15°
Fig. 3.108
150 POWER PLANT ENGINEERING
Fig. 3.109
First row of moving blades : and cut MN = 0.9 MS (∵ K 0.9)
To draw velocity triangles for first row of moving
— Join LN. The outlet velocity triangle is
blades the following procedure may be followed :
completed.
Select a suitable scale.
The following required data may now be scaled off
— Draw LM = blade velocity (Cbl) = 125 m/s.
from the diagram :
— Make MLS = nozzle angle, = 20°.
— Draw LS = velocity of steam leaving the nozzle Cw = Cw1 Cw0 = PQ = 845 m/s
= 600 m/sec. Cw = PQ = 280 m/s.
— Join MS to complete the inlet triangle LMS. (i) Diagram efficiency,
— Make LMN = outlet angle of first moving 2Cbl (Cw Cw )
blades = 20° bl =
C12
and cut MN = 0.9 MS, since K = 0.9.
— Join LN to complete the outlet LMN. 2 125( 845 280)
=
( 600)2
Second row of moving blades :
= 0.781 or 78.1%. (Ans.)
The velocity triangles for second row of moving (ii) Power developed,
blades may be drawn as follows :
s (Cw Cw )
m
— Draw LM = blade velocity (Cbl) = 125 m/sec. P= Cbl
1000
— Make MLS = outlet angle of fixed blade = 25°
6( 845 280) 125
and cut LS = 0.9 LN. (∵ K 0.9) =
1000
— Join MS. The inlet velocity triangle LMS is
= 843.75 kW. (Ans.)
completed.
152 POWER PLANT ENGINEERING
f
35°
= 78.54 m/s Cr 1 C0
Cf 1 Cf0
C
But = bl = 0.7 (given) C1 Cr0
C1
N
Cbl 75.54 S
C1 =
= 112.2 m/s
0.7 0.7
In Parson’s Turbine, = . Fig. 3.111
With the above data known, the velocity diagram Area of flow = Dmh, where h is the height of blade.
for the turbine can be drawn to a suitable scale as shown = × 1.1 × 0.1 = 0.3456 m2
in Fig. 3.110. Steam pressure = 1.75 bar
Dryness fraction of steam, x = 0.935
Cw 1 Cw 0 Speed of the turbine, N = 250 r.p.m.
Cbl = 78.54 m/s
M L s :
Rate of steam flow, m
P q f a Q
b Power developed, P :
DN 1.1 250
Cf 1 Cr 1 C0 Cf 0 Blade speed, Cbl =
=
2 m/s 60 60
112. = 14.4 m/s
C1 = Cr 0
N With the above given data the velocity diagram can
S
be drawn to a suitable scale as shown in Fig. 3.111.
Fig. 3.110 By measurement (from diagram),
1000
Mean flow rate is given by,
2.5 7600
s = Area of flow Velocity of flow = = 19 kW. (Ans.)
m 1000
Specific volume of steam
Work done per pair per kg of steam
0.3456 10.8 Efficiency =
= = 3.98 kg/s. hd
0.938
7600
Power developed, = = 0.757 = 75.7%. (Ans.)
10.04 1000
s (Cw Cw ) Cbl
m
P= 1 0
1000
+Example 3.21. A twenty-stage Parson turbine receives
steam at 15 bar at 300°C. The steam leaves the turbine at
3.98(30 15.45) 14.4
= 0.1 bar pressure. The turbine has a stage efficiency of 80%
1000
and the reheat factor 1.06. The total power developed by
= 2.6 kW. (Ans.)
the turbine is 10665 kW. Find the steam flow rate through
Example 3.20. In a reaction turbine, the fixed blades and
moving blades are of the same shape but reversed in the turbine assuming all stages develop equal power.
direction. The angles of the receiving tips are 35° and of the The pressure of steam, at certain stage of the turbine
discharging tips 20°. Find the power developed per pair of is 1 bar abs., and is dry and saturated. The blade exit angle
blades for a steam consumption of 2.5 kg/s, when the blade is 25° and the blade speed ratio is 0.75. Find the mean
speed is 50 m/s. If the heat drop per pair is 10.04 kJ/kg, diameter of the rotor of this stage and also the rotor speed.
find the efficiency of the pair. Take blade height as 1/12th of the mean diameter. The
Solution. Angles of receiving tips, thickness of the blades may be neglected.
= = 35° Solution. Number of stage = 20
Angles of discharging tips, = = 20°
Steam supply pressure = 15 bar, 300°C
Steam consumption, s = 2.5 kg/s
m
Exhaust pressure = 0.1 bar
Blade speed, Cbl = 50 m/s
Stage efficiency of turbine, stage = 80%
Heat drop per pair, hd = 10.04 kJ/kg
Power developed = ? Reheat factor = 1.06
Total power developed = 10665 kW
Efficiency of the pair = ?
Refer to Fig. 3.112. Steam flow rate, ms :
C1
Cr 1 C0
Cf 1 Cf 0 1
C1 Cr 0 Height of the blade, h = D (mean dia. of rotor)
12
S N s :
(i) Steam flow rate, m
Refer to Fig. 3.113.
Fig. 3.112
NS = PQ = 152 m/s Isentropic drop, (h)isentropic = h1 – h2
Work done per pair per kg of steam = 3040 – 2195 = 845 kJ/kg
= (Cw1 Cw0 ) Cbl = 152 × 50 overall = stage × Reheat factor
= 7600 Nm/kg of steam. = 0.8 × 1.06 = 0.848
154 POWER PLANT ENGINEERING
h (kJ/kg)
15 bar i.e.,Work done per kg per stage
= Cbl (2 × 1.33Cbl × 0.906 – Cbl)
Fig. 3.116
3.20. STEAM CONDENSERS continuous flow machines, the back pressure may be about
0.025 bar abs.
3.20.1. Introduction 3.20.3. Organs of a Steam Condensing Plant
A steam condenser is a device or an appliance in which A steam condensing plant mainly consists of the following
steam condenses and heat released by steam is absorbed by organs/elements :
water. It serves the following purposes :
1. Condenser (to condense the steam).
1. It maintains a very low back pressure on the
exhaust side of the piston of the steam engine or 2. Supply of cooling (or injection) water.
turbine. Consequently, the steam expands to a 3. Wet air pump (to remove the condensed steam,
greater extent which results in an increase in the air and uncondensed water vapour and gases
available heat energy for converting into from the condenser ; separate pumps may be
mechanical work. The shaded area in Fig. 3.117. used to deal with air and condensate).
(i.e., area 4455) shows the increase in work 4. Hot well (where the condensate can be
obtained by fitting a condenser to a non- discharged and from which the boiler feed water
condensing engine. The thermal efficiency of a is taken).
condensing unit therefore is higher than that of
non-condensing unit for the same available 5. Arrangement for recooling the cooling water in
steam. case surface condenser is employed.
3.20.4. Classification of Condensers
Mainly, condensers are of two types : (1) Jet condensers,
(2) Surface condensers.
In jet condensers, the exhaust steam and water
come in direct contact with each other and temperature of
the condensate is the same as that of cooling water leaving
the condenser. The cooling water is usually sprayed into
the exhaust steam to cause rapid condensation.
In surface condensers, the exhaust steam and
water do not come into direct contact. The steam passes
over the outer surface of tubes through which a supply of
cooling water is maintained. There may be single-pass or
double-pass. In single-pass condensers, the water flows in
one direction only through all the tubes, while in two-pass
condenser the water flows in one direction through the
tubes and returns through the remainder.
Fig. 3.117 A jet condenser is simpler and cheaper than a
surface condenser. It should be installed when the cooling
2. It supplies to the boiler pure and hot feed water
water is cheaply and easily made suitable for boiler feed or
as the condensed steam which is discharged from
when a cheap source of boiler and feed water is available.
the condenser and collected in a hot well, can be
A surface condenser is most commonly used because the
used as feed water for the boiler.
condensate obtained is not thrown as a waste but returned
3.20.2. Vacuum to the boiler.
Vacuum is sub-atmospheric pressure. It is measured as 3.20.5. Jet Condensers
the pressure depression below atmospheric. The
condensation of steam in a closed vessel produces a partial These condensers may be classified as :
vacuum by reason of the great reduction in the volume of (a) Parallel-flow type
the low pressure steam or vapour. The back pressure in (b) Counter-flow type
steam engine or steam turbine can be lowered from 0.013
to 0.2 bar abs. or even less. Since the steam engines are (c) Ejector type.
intermittent flow machines and as such cannot take Parallel flow and counter flow condensers are
the advantage of a very low vacuum, therefore, for most further sub-divided into two types : (i) Low level type
steam engines the exhaust pressure is about 0.2 to 0.28 bar (ii) High level type.
abs. On the other hand, in steam turbines, which are
158 POWER PLANT ENGINEERING
Cooling water
Condensate
Low level jet condenser (Parallel-flow) : To boiler
Extraction
In Fig. 3.118 is shown a line sketch of a low level
pump
parallel-flow condenser. The exhaust steam is entering the
condenser from the top and cold water is being sprayed on
its way. The baffle plate provided in it ensures the proper Hot well
mixing of the steam and cooling water. An extraction pump Overflow
at the bottom discharges the condensate to the hot well
from where it may be fed to the boiler if the cooling water
being used is free from impurities. A separate dry pump
may be incorporated to maintain proper vacuum. Cooling pond
Low level jet condenser (Counter-flow) : Fig. 3.119. Low level jet condenser (Counter flow).
Refer to Fig. 3.119. L, M and N are the perforated
High level jet condenser (Counter-flow type) :
trays which break up water into jets. The steam moving
In Fig. 3.120 is shown a high level counter-flow jet
upwards comes in contact with water and gets condensed.
condenser. It is also called barometric condenser. In this
The condensate and water mixture is sent to the hot well case the shell is placed at a height about 10.363 metres
by means of an extraction pump and the air is removed by above hot well and thus the necessity of providing an
an air suction pump provided at the top of the condenser. extraction pump can be obviated. However provision of own
injection pump has to be made if water under pressure is
Exhaust not available.
steam Air
Cold water
Baffle plate
Cooling water
To air pump
Exhaust
steam
Condensate
Dry air Injection
To boiler pump pump
Tail pipe
10.363 m
Condensate
extraction Overflow
pump
Overflow
Hot well
Hot well
Cooling pond
Cooling pond
Fig. 3.118. Low level jet condenser (Parallel flow). Fig. 3.120. High level jet condenser (Counter flow).
STEAM POWER PLANT 159
Cold at the lower half section and after travelling through the
water upper half section comes out through the outlet. The
exhaust steam entering shell from the top flows down over
the tubes and gets condensed and is finally removed by an
extraction pump. Due to the fact that steam flows in a
direction right angle to the direction of flow of water, it is
also called cross-surface condenser.
Exhaust Hollow
steam truncated
Exhaust
cones
steam
Non-return Tubes
Water Plate
valve
outlet
Baffle
plate
Diverging
cone
Water
inlet
Condensate to
Fig. 3.121. Ejector condenser.
extraction pump
Ejector condenser :
Fig. 3.122. Down flow type.
Fig. 3.121 shows the schematic sketch of an ejector
condenser. Here the exhaust steam and cooling water mix (ii) Central flow type
in hollow truncated cones. The cold water having a head of Refer to Fig. 3.123. In this type of condenser, the
about 6 metres flow down through the number of cones suction pipe of the air extraction pump is located in the
and as it moves its velocity increases and drop in pressure centre of the tubes which results in radial flow of the steam.
results. Due to this decreased pressure exhaust steam along The better contact between the outer surface of the tubes
with associated air is drawn through the truncated cones and steam is ensured, due to large passages the pressure
and finally lead to diverging cone. In the diverging cone, a drop of steam is reduced.
portion of kinetic energy gets converted into pressure
energy which is more than the atmospheric so that Steam
condensate consisting of condensed steam, cooling water
and air is discharged into the hot well. The exhaust steam
inlet is provided with a non-return valve which does not
allow the water from hot well to rush back to the engine in
case a failure of cooling water supply to condenser.
3.20.6. Surface Condensers
Air suction
Most condensers are generally classified on the direction pump
of flow of condensate, the arrangement of the tubing and
the position of the condensate extraction pump. The
following is the main classification of surface condensers :
(i) Down flow type (ii) Central flow type
(iii) Inverted flow type (iv) Regenerative type
(v) Evaporative type.
To condensate
(i) Down flow type pump
In Fig. 3.122 is shown a down flow type of surface
condenser. It consists of a shell which is generally of Fig. 3.123. Central flow type.
cylindrical shape ; though other types are also used. It has (iii) Inverted flow type
cover plates at the ends and furnished with number of
This types of condenser has the air suction at the
parallel brass tubes. A baffle plate partitions the water
box into two sections. The cooling water enters the shell top, the steam after entering at the bottom rises up and
160 POWER PLANT ENGINEERING
then agains flows down to the bottom of the condenser, by 6. Less chances of losing vacuum as the drop in
following a path near the outer surface of the condenser. vacuum has got no effect on water supply.
The condensate extraction pump is at the bottom. 7. Cooling water of even poor quality can be used
(iv) Regenerative type because the cooling water does not come in direct contact
with steam.
This type is applied to condensers adopting a
regenerative method of heating of the condensate. After Disadvantages :
leaving the tube nest, the condensate is passed through 1. High initial cost.
the entering exhaust steam from the steam engine or 2. Requires large floor area.
turbine thus raising the temperature of the condensate, 3. High maintenance cost.
for use as feed water for the boiler. 4. More head is necessary in order to obtain
(v) Evaporative type sufficient head on hot well pump.
Fig. 3.124 shows the schematic sketch of an 5. Proper cleaning of cooling water is necessary,
evaporative condenser. The underlying principle of this otherwise it creates the problem of accumulation of dust
condenser is that when a limited quantity of water is inside the condenser tubes.
available, its quantity needed to condense the steam can 3.20.7. Reasons for Inefficiency in Surface Condensers
be reduced by causing the circulating water to evaporate
under a small partial pressure. The various reasons for inefficiency in surface condensers
are discussed below :
The exhaust steam enters at the top through gilled
1. The pressure inside the condenser is less than
pipes. The water pump sprays water on the pipes and
atmospheric, and in order to obtain
descending water condenses the steam. The water which
the maximum work from unit mass of steam, the
is not evaporated falls into the open tank (cooling pond)
pressure should be as low as possible.
under the condenser from which it can be drawn by The pressure in the condenser also depends upon
circulating water pump and used over again. The the amount of air. Owing to high vacuum
evaporative condenser is placed in open air and finds its pressure in the condenser it is impossible to
application in small size plants. prevent air from leaking in through the joints
thereby increasing the pressure in the condenser
and thus limiting the amount of work done by
unit mass of steam in the engine or turbine. Air
Cooling water
5. Steam entering the condenser with high 1. There is a leakage of air from atmosphere at the
resistance. joints of the parts which are internally under a
6. Circulating water passing through the condenser pressure less than that of atmosphere. The
with high friction and at a velocity not consistent quantity of air that leaks in can be reduced to a
with high efficiency. great extent if design and making of the vacuum
7. Undercooling of condensate. joints are undertaken carefully.
8. Air extraction from hottest section and with 2. Air is also accompanied with steam from the
boiler into which it enters dissolved in feed
comparatively large amount of water vapour.
water. The quantity of air depends upon the
3.20.8. Comparison Between Jet and Surface treatment which the feed water receives before
Condensers it enters the boiler. However, the amount of air
which enters through this source is relatively
S. No. Jet condenser Surface condenser small.
1. Low manufacturing High manufacturing cost. 3. In jet condensers, a little quantity of air
cost. accompanies the injection water (in which it is
2. Lower up keep. Higher up keep. dissolved).
3. Requires small floor Requires large floor space. Notes. (i) In jet condensers, the quantity of air dissolved
space. in injection water is about 0.5 kg/10000 kg of water.
4. The condensate cannot Condensate can be reused (ii) In surface condensers of reciprocating steam
be used as feed water in as feed water as it does not engines, the air leakage is about 15 kg/10000 kg of steam
the boilers unless the mix with the cooling water. whereas in surface condensers of well designed and properly
cooling water is free maintained steam turbine plants the air leakage is about
from impurities. 5 kg/10000 kg of steam.
5. More auxiliary power Less auxiliary power
required. needed. 3.20.11. Effects of Air Leakage in Condenser
The following are the effects of air leakage in a condenser :
3.20.9. Selection of Condenser 1. Lowered thermal efficiency. The leakage air
in the condenser results in increased back-pressure on the
The selection of condenser depends on the following primem over which means there is loss of heat drop and
conditions : consequently thermal efficiency of steam power plant is
1. The first cost. The first cost of jet condenser lowered.
may be about one-fourth than that of an equivalent surface 2. Increased requirement of cooling water.
condenser. The leaked air in the condenser lowers the partial pressure
2. The maintenance cost. The maintenance cost of steam which means a lowered saturation temperature
of jet condensers is lower than that of surface condensers. of steam. As the saturation temperature of steam lowers,
3. The space available. The amount of floor space its latent heat increases. So it will require increased amount
and the head room available are not actually the deciding of cooling water for increased latent heat.
factors. Surface condensers require more floor space than 3. Reduced heat transfer. Air has poor thermal
the jet condensers. conductivity. Hence leaked air reduces the rate of heat
transfer from the vapour, and consequently it requires
4. The quantity of cooling water. The quantity,
surface of the tubes of a surface condenser to be increased
quality and source of cooling water are the important
for a given condenser capacity.
considerations in the selection of the condenser where the
4. Corrosion. The presence of air in the condenser
water supply is limited, an artificial cooling system can be
increases the corrosive action.
installed. For artificial cooling the cooling ponds and cooling
towers are used. 3.20.12. Method for Obtaining Maximum Vacuum in
5. The type of boiler feed-water available. This Condensers
is an important factor in the selection of condenser. The Following are some of the methods used to obtain maximum
surface condenser recovers the distilled condensate for possible vacuum in condensers used in modern steam power
boiler feed-water whereas in case of jet-condenser it is not. plants.
3.20.10. Sources of Air in Condensers 1. Air pump. Air pumps are provided to maintain
a desired vacuum in the condenser by extracting the air
The main sources of air found in condensers are given and other non-condensable gases. They are usually
below :
162 POWER PLANT ENGINEERING
classified as : (a) Wet air pumps which remove a mixture Corrected vacuum in mm of Hg
of condensate and non-condensable gases. (b) Dry air pump = (760 – Absolute pressure in mm of Hg)
which removes the air only. = 760 – (Actual barometric height –
Actual vacuum)
2. Steam air ejector. When a wet air pump (also
Also, 760 mm of Hg = 1.01325 bar
called extraction pump) is employed then use is made of
steam air ejectors to remove air from the mixture. The 1.01325
mm of Hg = = 0.001333 bar
operation of the ejector consists in utilising the viscous drag 760
of a high velocity steam jet for the ejection of air and other 3.20.14. Vacuum Efficiency
non-condensable gases from a chamber ; it is chiefly used
It is defined as the ratio of the actual vacuum to the
for exhausting the air from steam condensers. In the case
maximum obtainable vacuum. The latter vacuum is
of ejectors used for steam plants where a high vacuum
obtained when there is only steam and no air is present in
pressure is maintained in the condenser, it is necessary to
the condenser.
use two, or perhaps three ejectors in series to obtain
maximum vacuum. Vacuum efficiency
3. De-aerated feed water. The de-aeration of feed Actual vacuum
=
water helps both in maintaining better vacuum in the Maximum obtainable vacuum
condenser and controlling corrosion of the steel shell and Actual vacuum
piping of the steam power plant. =
Barometer pressure – Absolute
4. Air tight joints. The various joints of the steam pressure of steam
power plant are rendered air-tight by suitable packing
...(3.73)
materials etc. at the joints of piping etc. and these are
Note. In case of the absolute pressure of steam
maintained as such by proper inspection from time to time.
corresponding to the temperature of condensate being
3.20.13. Vacuum Measurement equal to the absolute pressure in the condenser, the
efficiency would be 100%. Actually some quantity of air is
The term vacuum in case of a condenser means pressure also present in the condenser which may leak in and be
below atmospheric pressure. It is generally expressed in accompanied by the entering steam. The vacuum
mm of mercury. The vacuum is measured by means of a efficiency, therefore, depends on the amount of air removed
vacuum gauge (Fig. 3.125). Usually for calculation purpose by the air pump from the condenser.
the vacuum gauge reading is corrected to standard
barometric reading 760 mm as follows. 3.20.15. Condenser Efficiency
It is defined as the ratio of the difference between the outlet
Vacuum gauge and inlet temperatures of cooling water to the difference
between the temperature corresponding to the vacuum in
the condenser and inlet temperature of cooling water, i.e.,
Condenser Condenser efficiency
shell
Rise in temperature of cooling water
Torricelli’s =
LM
Temp. corresponding to vacuum OP
vacuum
N in the condenser Q
L
M
Inlet temp. of OP
Absolute
Ncooling water Q
pressure
Barometric height
N Q
Vacuum
M
LInlet temp. of O
Ncooling water PQ
Baromertric
pressure
tubes under air or water pressure. Fig. 3.126 shows the to use the same water over and over again by cooling it in
various types of plugs used for cleaning of the condenser a suitable device. Such devices as commonly employed in
tubes. power stations are the cooling ponds and cooling towers.
Sometimes a combination of natural supply and artificial
cooling may be adopted.
Condenser
Rubber Rubber plug Franklin Franklin
plug with fabric backing rubber ring scraper plug Pump
3.21. COOLING PONDS AND COOLING Fig. 3.127. River water cooling system.
TOWERS
3.21.3. Cooling Ponds
3.21.1. Introduction The cooling ponds are the simplest of the device for recooling
Even in today’s many efficient steam plants at least half of the cooling water. A cooling pond consists of a large,
the energy input must be rejected as unavailable in the shallow pool into which the hot water is allowed to come in
steam-turbine exhaust. The main steam condenser performs contact with the atmospheric air. Fig. 3.128 shows a non-
the dual function of removing this rejected energy from the directed flow naturally cooling pond and Fig. 3.129
plant cycle and keeping the turbine back pressure at the illustrates a directed flow natural cooling pond. Its cooling
lowest possible level. The rejected energy inevitably must effect is more than the non-directed flow pond as water
be returned to the atmosphere. The main condenser does comes in contact with air at lower temperature.
this by transferring the latent heat of the exhaust steam In a cooling pond no spray or other cooling device is
to water exposed to the atmosphere. This water we call employed thus keeping the operating expenses quite low.
circulating, or cooling, water. The cooling water The cooling pond is suitable where sufficient supply of
requirement in an open system is about 50 times the flow circulating water is not available. In case the amount of
of steam to the condenser. Even with closed cooling system cooling water to be cooled is very large, as in the case of big
using cooling towers, the requirement for cooling water is power plants, the cooling ponds will have to be made very
also considerably large as 5 to 8 kg/kWh. This means a large thus making it prohibitive. For large power plants
1000 MW station will require about 100 thousand tons of therefore, spray ponds should be used. The depth of cooling
circulating water per day even with the use of cooling pond should be around one metre.
towers. Thus the source of cooling water chosen should be
able to supply the required quantity of cooling water. The Hot water discharge
cooling water supply is made by the following sources :
1. River or sea. 2. Cooling ponds.
3. Spray ponds. 4. Cooling towers. Natural flow pond
Power
3.21.2. River or Sea house
Intake
When the power station situated on the bank of a river or
lake or other natural source of water, the condenser water
supply can be obtained directly from there, the water being
discharged to the waste or back to the source (Fig. 3.127).
However, it is not always possible to locate central Fig. 3.128. Non-directed flow natural cooling pond.
stations near the source of supply and it becomes necessary
STEAM POWER PLANT 165
Directed flow pond some water is evaporated and is taken away with air. In
evaporation the heat is taken away from the bulk of water,
which is thus cooled.
Intake Factors affecting cooling of water in a cooling tower
are :
Power 1. Temperature of air.
house 2. Humidity of air.
3. Temperature of hot air.
Discharge
concrete hyperbolic cooling tower is shown in Fig. 3.131. closed and form an air and water tight structure, except
This tower has the following advantages over mechanical for fan openings at the base for the inlet of fresh air, and
towers : the outlet at the top for the exit of air and vapours. There
(i) Low operating and maintenance cost. are hoods at the base projecting from the main portion of
the tower where the fans are placed for forcing the air,
(ii) It gives more or less trouble free operation.
into the tower.
(iii) Considerable less ground area required.
(iv) The towers may be as high as 125 m and 100 m Air out
in diameter at the base with the capability of
withstanding winds of very high speed. These
structures are more or less self-supported
Hot water
structures.
in
(v) The enlarged top of the tower allows water to
fall out of suspension.
The main drawbacks of this tower are listed below :
(i) High initial cost. Packing
(ii) Its performance varies with the seasonal changes
in DBT (dry bulb temperature) and R.H. (relative
humidity) of air.
Air in
Cold water
out
Cold water
(ii) In evaporative cooling system (cooling towers)
out due to continuous evaporation of water, the concentration
of impurities goes on increasing and so the disposal of tower
Fig. 3.133. Induced draught cooling tower.
blow down may become a serious problem at some sites.
Induced Draught Cooling Towers Besides this make up water for tower use is limited in some
areas.
Advantages :
Thus the use of dry cooling towers in power plants
1. The coldest water comes in contact with the driest
air and warmest water comes in contact with the most in the only alternative. The dry system rejects the heat
humid air. directly to the atmosphere which is the largest heat sink
2. In this tower, the recirculation is seldom a available.
problem. Following are two basic types of closed cooling water
3. Lower first cost (due to the reduced pump systems for power plants utilising dry cooling principle.
capacity and smaller length of water pipes).
1. Direct system
4. Less space required.
5. This tower is capable of cooling through a wide 2. Indirect system.
range. 1. Direct System. Refer to Fig. 3.134. In direct
Disadvantages : system the exhaust steam from the turbine is passed on to
1. The air velocities through the packings are the cooling coils where it is condensed directly by means of
unevenly distributed and it has very little movement near air. Cooling coils constitute air cooled condenser. This
the walls and centre of the tower. system has the disadvantage that large ducts are needed
2. Higher H.P. motor is required to drive the fan to convey the exhaust steam to the exchanger coils, to
comparatively. This is due to the fact that the static minimise the pressure drop. This places a practical limit
pressure loss is higher as restricted area at base tends to on the size of the unit. This system is limited to maximum
choke off the flow of higher velocity air. generator unit sizes of 200 MW to 300 MW.
Comparison between Natural and Mechanical 2. Indirect System. Refer to Fig. 3.135. In this case,
Draught Towers the exhaust steam is condensed in a spray condenser by
means of circulating water. The major part of the water
Mechanical Draught Towers
from the condenser flows back to the cooling coils and an
Advantages : amount equal to the exhaust steam from the turbine is
1. These towers require a small land area and can directed back to the boiler feed water circuit. Some energy
be built at most locations. recovery is possible by using hydraulic turbine (T) to drive
2. The fans give a good control over the air flow the circulating water pumps. This system is applicable to
and thus the water temperature. all large unit sizes.
168 POWER PLANT ENGINEERING
3115.3 1215
. 588 The total pressure in the condenser is 0.06624 bar,
x= = 0.988. (Ans.) hence,
2432.9
0.06624 = 0.0594 + pa
(ii) Quantity of circulating water, mw : pa = 0.00684 bar
Ratio of cooling : The mass of air removed per hour is
Heat lost by condensing steam = Heat gained by 20000 0.3
cooling water = 6 kg/h
1000
Hence the volume of air removed per hour is
ms [hf + x hfg – hc] = mw × cpw × ( tw2 – tw1 )
mRT 6 0.287 ( 273 36) 103
ms [ hf x hfg hc ] =
or mw = p 0.00684 105
c pw (tw2 tw1 )
= 778 m3/h
15000 [121.5 0.988 2432.9 The mass of steam associated with the air removed
4.186 31] is therefore given by
=
4.186 10 778
= 858375 kg/h. (Ans.) = 32.45 kg/h.
23.97
[where cpw = specific heat of water = 4.186 kJ/kg K] Separate extraction :
mw 858375 At 27°C : Saturation pressure
Ratio of cooling = = = 0.03564 bar, vg = 38.81 m3/kg
ms 15000
= 57.225 kg. (Ans.) The air partial pressure
= 0.06624 – 0.03564 = 0.0306 bar
+ Example 3.32. A surface condenser is required to deal The volume of air removed
with 20000 kg of steam per hour, and the air leakage is
estimated at 0.3 kg per 1000 kg of steam. The steam enters mRT 6 0.287 ( 273 27 ) 103
= =
the condenser dry saturated at 38°C. The condensate is p 0.0306 105
extracted at the lowest point of the condenser at a = 168.9 m3/h
temperature of 36°C. The condensate loss is made up with
168.9
water at 7°C. It is required to find the saving in condensate Steam removed = = 4.35 kg/h.
and the saving in heat supplied in the boiler, by fitting a 38.81
separate air extraction pump which draws the air over an Hence, the saving in condensate by using the separate
air cooler. Assume that the air leaves the cooler at 27°C. extraction method
The pressure in the condenser can be assumed to remain = 32.45 – 4.35 = 28.1 kg/h. (Ans.)
constant. The saving in heat to be supplied in the boiler
Solution. The mass of air per kg of steam at entry = 28.1 × 4.186 (36 – 7)
= 0.3/1000 = 0.0003 kg = 3411 kJ/h. (Ans.)
At 38°C : Saturation pressure = 0.06624 bar and Example 3.33. For the data of example 3.32, calculate :
vg = 21.63 m3/kg (From steam tables)
(i) The percentage reduction in air pump capacity
For 1 kg of steam, the volume is 21.63 m3, and this by using the separate extraction method.
must be the volume occupied by 0.0003 kg of air when
exerting its partial pressure, (ii) If the temperature rise of cooling water is 5.5 K,
i.e., Partial pressure of air calculate the mass flow of cooling water required.
ma RaT Solution. Capacity of air pump without air cooler
=
V = 778 m3/h
0.0003 0.287 (273 38) 103 Capacity of air pump with air cooler
= = 168.9 m3/h.
21.63 105
–5 Percentage reduction in capacity
= 1.2 × 10 bar
This is negligibly small and may be neglected. FG
778 168.9IJ
Condensate extraction :
= H 778 K
× 100 = 78.3%. (Ans.)
At 36°C : Saturation pressure Fig. 3.136 shows the system to be analysed. Let
= 0.0594 bar, vg = 23.97 m3/kg. suffixes s, a, and c denote steam, air and condensate
respectively.
174 POWER PLANT ENGINEERING
A 461601 N
50 38.31 Q
Surface area per tube = = = 2308 Now, Q = UoAm
200 200
i.e., × d × l = 2308 230 × 106 = 6525.4 × ( dL) × (2Np) × 19.43
× 2.8 × l = 2308 = 6525.4 × ( × 0.02 × L) × (2 × 3000)
l = 262.4 cm. (Ans.) × 19.43
Example 3.35. A steam condenser consists of 3000 brass
230 10 6
tubes of 20 mm diameter. Cooling water enters the tubes at L=
20°C with a mean flow rate of 3000 kg/s. The heat transfer 6525.4 0.02 (2 3000) 19.43
coefficient on the inner surface is 11270 W/m2°C, and that = 4.812 m. (Ans.)
for condensation on the outer surface is 15500 W/m2°C. Example 3.36. A two-pass surface condenser is required
The steam condenses at 50°C, and the condenser load is to handle the exhaust from a turbine developing 15 MW
230 MW. The latent heat of steam is 2380 kJ/kg. Assuming with specific steam consumption of 5 kg/kWh. The
counter flow arrangement, calculate the tube length per pass condenser vacuum is 660 mm of Hg when the barometer
if two tube passes are used. reads 760 mm of Hg. The mean velocity of water is 3 m/s,
Solution. Given : Np = 3000 per pass ; d = 20 mm = water inlet temperature is 24°C. The condensate is saturated
0.02 m ; tc1 = 20°C ; m c = 3000 kg/s ; hi = 11270 W/m2°C ;
Steam in (x = 0.9)
2
ho = 15500 W/m °C, th1 = th2 = 50°C ; condenser load = 230 W
(or 230 × 103 kW) ; hfg = 2380 kJ/kg ; number of passes = 2.
Two-pass surface
condenser
th1 = th2 = 50°C
Steam
tc1 (=20°C)
Condensate out
Fig. 3.137
th1 = th2 = tsat = 51°C
Tube length per pass, L :
tc2 = 47°C
Assuming the tubes to be thin, the overall heat
transfer coefficient :
1 1
Uo =
1 1 1 1
tc1 = 24°C
hi ho 11270 15500
= 6525.4 W/m2°C Fig. 3.138. A two-pass surface condenser.
176 POWER PLANT ENGINEERING
3.22.2. Troubles Caused by the Impurities in Water 3. Carryover. Water solids carried over in the
steam leaving a boiler drum are called “carry-over”.
The impurities in water may cause one or more of the
Foaming or priming of the boiler water forms the carry-
following troubles :
over. In “foaming”, bubles form on the water surface and
1. Scale formation 2. Corrosion may fill the drum steam space. Excessive amounts of sodium
3. Carryover 4. Embrittlement. alkalinity, or finaly divided calcium phosphate, or oil may
1. Scale formation. The formation of scale reduces cause foaming. “Priming” refers to the vigorous and periodic
heat transfer and simultaneously raises the temperature of surging of water in the boiler drum and throws water slugs
the metal wall. When temperature of boiler tube material into the leaving steam. This may be caused by excessive
reaches 450°C to 500°C, there is a serious danger of steaming rate, too high or fluctuating a water level, and
overheating and consequently rupture of boiler plates. The improper boiler-water circulation. Carryover may originate
scaling results from the decrease of solubility of some salt from mechanical or chemical causes.
with increase of temperature. It is formed by crystallisation The following detrimental results are caused by the
of scale-forming salts from a locally super-saturated layer carry-over. The water droplets carrying solids evaporate
of water lying on the heating surface. This forms an and build deposits in the valves, superheaters, and piping
incrustation at the point of evaporation. Scale is due to and even in the turbine or engine.
mainly the salts of calcium and magnesium as also to a (i) Superheater deposits reduce heat transfer and
certain extent the salts of silicates. Calcium sulphate is raise the tube-metal temperatures.
essentially responsible for the formation of scale.
(ii) Deposits on turbine blade reduce efficiency and
The scale chokes the flow in the piping system and capacity and may unbalance the rotor.
thus requires increased pressure to maintain water
(iii) Deposits forming on governing valves raise a
delivery. The accumulation of scale may become so thick
serious hazard.
that the temperature drop from gas to water is through
the scale only. This will result in overheating, blistering Foaming and priming can be checked by taking the
and rupturing. When scale is formed, tubes are cleaned following prrecautions :
with electric-powered rotary brushes and cutters are 1. Valves not to be opened suddenly to maximum.
pushed through the tubes during boiler overhaul. 2. Water level in the boiler should be at its minimum
2. Corrosion. The corrosion is the eating away possible level.
process of boiler metal. Corrosion in power-plant equipment 3. The boiler water should not contain oil, soap and
produces pits, grooves and cracks or a general wastage of other suspended impurities.
the wall material. Allowed to continue, corrosion ultimately
makes metal parts fail. 4. Embrittlement. The caustic embrittlement is the
The corrosion is caused by an acid or low pH in weakening of boiler steel as a result of inner crystalline
addition to the presence of dissolve oxygen and carbon cracks. Presence of certain concentration of sodium
dioxide in the boiler feed water. The presence of oxygen is hydroxide causes embrittlement.
mostly responsible for corrosion among all other factors. The following three conditions contribute to
Oxygen generally enters a closed system through make- embrittlement :
up condenser leakage and condensate pump packings. The (i) Slow boiler-water leaks through cracks or seams
carbon dioxide is next to oxygen which is responsible for vapourises to leave behind a built-up of salts.
corrosion, it comes out of bicarbonates on heating and it (ii) The metal must be stressed by cold working
combines with water to form weak acid known as carbonic during fabrication, or riveting, or from expansion and
acid. This acid slowly reacts with iron and other metals to contraction.
form their bicarbonates. The new bicarbonates of metals (iii) The concentrated water in a crack must have
formed are decomposed by heat once more and carbon chemical properties that will attack the metal.
dioxide is again liberated. This gas again unites with water
This defect is not very common but very important.
to form carbonic acid and the cycle is repeated.
It affects the drum and its presence cannot be traced so
The corrosion can be controlled by adding alkali salts
easily.
to neutralise acids in water and raise the pH value (it is
the logarithm of the reciprocal of hydrogen ion To measure embrittlement, a detector is installed in
concentration). The effect of CO2 is neutralised by the the boiler where boiler water will circulate over it
addition of ammonia for neutralising amines in water. This continuously, as in a continuous blowdown line.
is necessary because CO2 lowers the pH of the boiler feed Some of the methods to control embrittlement are
water. The effect of oxygen is reduced only by removing listed below :
the oxygen from water. The corrosion of metal surfaces can 1. Elimination of free sodium hydroxide from boiler
be prevented by applying protecting coating of amines to water.
the internal surfaces of boilers and economisers.
178 POWER PLANT ENGINEERING
Rate of flow
Indicator
Pressure
gauge
Raw-water Sight
Inlet valve glass Typical bed
fine sand or
Venturi
filter material
nozzle
40–50 mm thick
about 1 mm size
Pressure
gauge
Strainer
heads
Filtered
water
Back wash supply
Filtered water outlet
to waste
(iii) Filtration. The suspended matter which and heating trays. From the bottom of heating trays, the
cannot be removed during sedimentation are removed with remaining steam and separated gases such as oxygen etc.
the help of filtration. The water is allowed to pass through flow to the vent condenser. The steam used for heating
a bed of fine sand or graded sand and then a layer of gravels may be main turbine bled steam or may be from other
etc. as shown in Fig. 3.139. The suspended matter adheres sources. Storage tank with controls help to add make up
to the filter material leaving the water clear as it drains water when needed to maintain the feed water level.
from the bottom. The beds must be backwashed periodically (ii) Distillation by evaporators. An evaporator’s
to remove the dirt that collects in the voids of the filter function is to produce from raw water, vapour that can be
material. condensed to distilled water for boiler feed make-up. In
In case of pressure filter (Fig. 3.139) the water is some cases the use of evaporators is required where the
forced through the filter by means of a pump whereas in make-up water percentage is small say upto 4 per cent. In
gravity filter the water flows by gravity. case of regenerative cycle, the evaporator is quite useful
as the steam used for evaporation is being used in feed
2. Thermal Treatment
water itself. It has the advantage of requiring lesser or
(i) Deaeration. The process of removing dissolved very little blow down of deconcentration in the boiler. An
oxygen is known as deaeration. This is done in deaerating evaporator system may be single effect where steam is
heaters. If water is heated to a temperature of about 110°C produced from one evaporator or multiple effect in which
with subsequent agitation, the dissolved oxygen is expelled. steam is produced from several evaporators in series. They
Fig. 3.140 shows a tray type deaerating heater. In may also be classified as film type, flash type and submerged
this heater feed water after passing through the vent tube type.
condenser is sprayed upwards in the spray pipe. Water
falls in the form of uniform showers over the heating trays 3. Chemical Treatment
and air separating trays and finally gets collected in the Lime-soda softening process. This process uses
storage space. Steam enters the heater through a nozzle calcium hydroxide (lime) and sodium carbonate (soda ash),
fitted in the side of heater shell. The entire space between to remove dissolved calcium and magnesium salt, by
the shell and tray compartment gets filled with steam. The precipitating them. This may be done by either a cold
steam makes its way downwards through the perforations process or hot process. The processes use these types of
reactions :
Level
Vent Mg(HCO3)2 + 2Ca(OH2) = Mg(OH)2 + 2CaCO3
control
Vent + 2H2O ...(3.81)
condenser MgCl2 + Ca(OH)2 = Mg(OH)2 + CaCl2 ...(3.82)
CaCl2 + Na2CO3 = CaCO3 + 2NaCl ...(3.83)
Spray pipe CaSO4 + Na2CO3 = CaCO3 + Na2SO4 ...(3.84)
The arrows show the molecule precipited from the
Heating solution.
trays Eqn. (3.81) : All the carbonate hardness is
Steam
precipitated out, leaving pure water.
inlet
Eqns. (3.82) to (3.84) : The non-carbonte hardness
Air precipitates, to be replaced by soluble sodium salts.
separator The magnesium hydroxide [Mg(OH)2] acts as a
Over flow trays coagulant and has the property of absorbing soluble silica
from solution. The original matter hardness usually is not
Loop seal Float completely removed in hot process softner (used in power
cage plants) because of the chemical cost. Even when some
excess chemicals are used, the effluent hardness will range
To from 10 to 30 ppm (parts per million).
storage
tank
Hot-process phosphate softening uses trisodium
phosphate and caustic sode to precipitate and remove
Fig. 3.140. Tray type deaerating heater. calcium and magnesium hardness. The reactions are as
follows :
in the top plate of tray compartment. While flowing
downward the steam comes in contact with the falling 3Ca(HCO3)2 + 6NaOH = 3CaCO3 + 3Na2CO3 +
water. Most of the steam condenses in between the spray 6H2O ...(3.85)
180 POWER PLANT ENGINEERING
3CaCO3 + 2Na3PO4 = Ca3(PO4)2 + 2Na2CO3 Fig. 3.141 shows a typical zeolite softener. It consists
of a shell holding a bed of active sodium zeolite supported
...(3.86)
by layers of graded gravel lying over a water distribution
Mg(HCO3)2 + 4NaOH = Mg(OH)2 + 2Na2CO3 and collection system. Zeolites almost completely remove
+ 2H2 ...(3.87) hardness but do not reduce alkalinity or total solids. Turbid
3CaSO4 + 2Na3PO4 = Ca3(PO4)2 + 3Na2SO4 water does not react well with zeolite sands. They do not
...(3.88) remove silica and may even add it. The exhaustion capacity
Phosphates also remove silica compounds, which are of the zeolite bed should be known, because regeneration
troublesome in high pressure boilers. Phosphate chemicals should be started as soon as the exhaustion starts.
cost more than lime-soda. First back washing should be done by passing a
Ion Exchange Processes strong current of water upwards. A measured quantity of
common salt solution should then be injected in the softner.
(i) Sodium zeolite process. The zeolites are solid
The salt reacts with the zeolite thus removing calcium and
materials of a sandy texture. They remove various ions
magnesium in the form of soluble chlorides. After salt rinse
from the water replacing them with other ions of like
zeolite filter is ready to be used again. The equation of this
charge. In case of sodium zeolite, the reactions are as
reaction is :
follows :
Ca(HCO3)2 + Na2Z = CaZ + 2NaHCO3 CaZ + 2NaCl = Na2Z + CaCl2 ...(3.92)
...(3.89) MgZ + 2NaCl = Na2Z + MgCl2 ...(3.93)
CaSO4 + Na2Z = CaZ + Na2SO4 ...(3.90) The entire regeneration period should not consume
CaCl2 + Na2Z = CaZ + 2NaCl ...(3.91) more than 3 to 4 minutes.
(Z is the symbol used for zeolite).
Raw water
Air
Salt relief
storage
Float
control
Ejector
Zeolite
Gravel
Brine
tank
The main merit of this process is that the water high anion exchangers to produce essentially distilled water.
in carbonates including sodium carbonate or bicarbonate Demineralisation is often the most economical method of
can be softened easily without replacing the water with some producing make-up water for high-pressure boilers.
other salt. Fig. 3.142 shows a series process for demineralisation. A
4. Demineralisation. The mineral content of water simple demineraliser would use only the first two units.
may be removed by evaporation or by series of cation and
Rain water
Cation Anion
exchanger exchanger Degasi- Silica
exchanger
fier
To service
4. It should be possible to carry out inspection and — For ‘steam pipes’ of high temperature alloy steels
maintenance on any section of the plant without are used.
the need for complete shut-down. — For temperature above 450°C alloy steel
5. The pipes should be made in longest possible containing chromium, vanadium, molybdenum
lengths to reduce the number of joints. and nickel is used. Chromium improves
6. Should be able to withstand the temperature and corrosion and oxidation resistance. Nickel adds
expansion caused due to the temperature toughness to the materials. Molybdenum
changes. improves creep strength.
7. The piping supports, anchors and joints should — Stainless steel is also used in a number of
be in accessible positions so that inspection is modern power plants where the pressures and
possible throughout the life of the plant. temperatures of steam are quite high.
8. The pipe should run as direct and straight as — Pipe of large size carrying very high pressure and
possible. temperature steam is made by turning and
boring solid forgings.
9. The piping system should ensure an efficient
drainage of all pipes. 3.23.3. Insulation of Steam Piping
10. To reduce the erection time the template pipes Insulating hot pipes not only conserves heat but also avoids
should be as few as possible. an uncomfortable overheated atmosphere in the vicinity
11. Steam piping system should be installed in such of pipe. The insulating material used for steam pipes should
a way that the horizontal runs should slope in possess the following properties :
the direction of steam flow. 1. Should possess high insulating-efficiency
FG IJ
bare surface loss insulated loss
H K
3.23.2. Materials used for Pipes .
bare surface loss
The materials for steam piping fall into following three
general classes : 2. Should not be too costly.
3. Should be easily moulded and applied.
1. Wrought iron
4. Should not be affected by moisture.
2. Cast iron
5. Should have high mechanical strength.
3. Steel.
6. Should be able to withstand high temperature.
1. Wrought iron. Wrought iron pipe is used where 7. Should not cause corrosion of pipes if chemically
corrosive conditions exist especially in hot water lines, decomposed.
underground piping and special plumbing installation. 8. Should not overload the pipe by its dead weight.
2. Cast iron. Cast iron pipes are also used for low
pressure. It is used for water services upto a pressure of 3.23.4. Steam Pipe Fittings
15 kgf/cm2 or for gas, drain piping etc. Steam pipes do not These are used to assemble piping system and make
use cast iron. connections. The various fittings which are in common use
3. Steel. Steel pipes are being widely used having are elbows, bends, tees, crosses, plugs and reducers. In
different percentage of metals in the alloy of steel depending Fig. 3.143 are shown the various fittings. The material used
upon the purpose for which they are used. for fittings depends on service as regard pressure and
temperature.
1 2 3 4 5
6 7 8 9
Fig. 3.143. Steam pipe fittings.
STEAM POWER PLANT 183
Expansion loop
Fig. 3.144. Pipe expansion bends.
Expansion joints provide flexibility to the piping
system by permitting relative motion between pipe sections.
They compensate for changes in dimensions due to
temperature variations. These joints being flexible, can Spigot end Lead White yarn Socket end
isolate vibration and can allow the ground settling if used
underground. Most of the joints permit considerable axial Fig. 3.148. Socket and spigot joint.
movement.
Fig. 3.145 shows the expansion joint. 3.24. ADVANTAGES AND DISADVANTAGES
OF STEAM POWER PLANTS
Advantages of Steam Power Plants :
1. They can respond to rapidly changing loads
without difficulty.
2. A portion of the steam generated can be used as
a process steam in different industries.
3. Can be located very conveniently near the load
centre.
4. As these plants can be set up near the industry
transmission costs are reduced.
5. Steam engines and turbines can work under
25 per cent of overload continuously.
Fig. 3.145. Expansion joint. 6. Fuel used is cheaper.
Screwed, welded and socket and spigot joints are 7. Less space is required in comparison with that
shown in Figs. 3.146, 3.147 and 3.148 respectively. for hydroelectric plants.
184 POWER PLANT ENGINEERING
alternator
discharged to the boiler drum. The water flows
through the water tubes due to natural
Coal bunkers
circulation. Forced circulation can also be done
with the help of pumps.
Boiler Turbo- — The steam generated then flows through the
alternator superheater tubes into steam header. From here
Office the steam enters the steam turbine through a
pipe.
Fig. 3.149. Plant arrangement. — Steam expands in the turbine and work done is
1. Similar items such as turbines, boilers, utilised to run a hydrogen cooled generator.
transformers, bunker bays and other mechanical and — Bled steam for feed water heating in feed water
electrical components—to be arranged in parallel lines. heaters is extracted from the turbine at three
Individual boiler, turbo-generator etc.—to be points.
arranged at right angles rows. — The exhaust steam flows into a surface type
2. The chimneys should be installed independent of condenser where it is condensed by means of
station building. Each chimney may serve two or more cooling water. There is a cooling tower to recool
boilers. this circulating water.
3. The following components should be located — The condensate is first heated in open or closed
behind the boiler house : type feed heater and then enters the boiler drum
via the economiser.
(i) Main flue
STEAM POWER PLANT 185
Over head
crane
Economiser
Water
Coal elevator
Precipi-
tator
Fur-
preheater
Steam nace
Air
Generator
Exciter Stoker
Ash hopper
Hydrogen Motor Coal
Heaters
for cooling I.D. conveyor
fan
C.T.
C
Condenser
P F.D. fan
Condensate
pump
Raw water
Fig. 3.150. Typical layout/schematic arrangement of a steam power plant.
S. No. Particulars Steam power plants Hydroelectric Diesel power plants Nuclear power plants
power plants
1. Site Located near load cen- The site should be Can be installed any- Located near the
tres but other factors such that sufficient where. load centre.
water supply, land cost, area, huge quantity of
transportation facilities water at a sufficient
are to be kept in view. head, cheap and rocky
Location of steam power land and transporta-
plant is somewhat tion facilities should
flexible as compared be available.
with that of hydro- These plants are usu-
plants. ally at a far off dis-
tance from the load
centres.
2. Initial cost Low as compared to hy- High as compared to Initial cost is the The capital cost is very
droelectric and atomic steam power plant on minimum. high as compared to all
power plants. account of large other types of power plants
amount of excavation on account of heavy cost of
work and heavy cost nuclear reactors and heavy
of transportation of cost of erection as highly
the plant and machin- specialised and expert en-
ery. gineers are required for its
erection work.
3. Fuel transpor- High, especially when Nil (as no fuel is re- Higher than that of Very low (since quantity of
tation cost the power plants are quired). atomic power plant fuel required is very
away from the coal but lower than that small).
mines and has no rail- for steam power
way siding. plants.
4. Operating Very high as compared Practically nil (since Very high as com- Very low as compared to all
cost to hydro-plants and no fuel is required for pared to all other other types of power plants
atomic power plants but the operation of the types of power plants. except that of hydroelectric
low as compared to die- plant). plants.
sel power plant.
5. Maintenance Higher as compared Maintenance cost is Maintenance cost is Maintenance cost is com-
cost with that of hydro- comparatively low comparatively lower paratively higher (be-
plants and diesel power (because few skilled (because lesser oper- cause skilled and well
plants (because large op- engineers and small ating and supervising trained staff is required
erating staff and more operating staff is re- staff is required). for its operation and main-
skilled engineers are re- quired). tenance).
quired).
6. Limit of source Source of fuel i.e., coal Source of power i.e., Source of fuel i.e., die- The source of power is un-
of power reserve all over the water in case of hy- sel is not available in limited since large deposits
world is considered to be dro-plants is not de- plenty. of fissionable materials all
fixed and therefore coal pendable because it over the world are avail-
mines are being ex- depends upon the able.
hausted and time may rainfall which is at
come when all of these the whim of nature.
might get exhausted.
7. Transmission Low (because short Very high (because Transmission cost is Very low.
and distribu- transmission lines are long transmission nil and distribution
tion cost. required). lines are required). cost is also very small.
9. Simplicity Atmosphere is polluted Most simple and Simple and cleaner The handling of atomic
and cleanli- by fumes and residues of clean. than steam plants power plant is quite compli-
ness pulverised fuels. and atomic power cated as radiation hazards
plants. are involved in it. Special
outfits are designed and ex-
plored by the operating staff.
10. Field of appli- Most economical if sited Most economical These plants are in- Where neither water nor coal
cation near coal mines and by where water stalled to supply as a source of power is avail-
the side of river or canal. source is available power is emergency. able, as in Rajasthan these
at a sufficient plants are more feasible and
head. adopted.
3.25.7. Indian Boilers Act or steam pipe which is calculated to weaken the strength
thereof so as to render it liable to explode.
For steam boilers Government of India enforced an Act
known as Indian Boilers Act, 1923. This Act came in force Boiler. Boiler means any closed vessel exceeding
from 1st January, 1924 (and later on ended in 1953). Some 22.75 litres in capacity which is used expressly for
of the sections of the Act are given below : generating steam under pressure and includes any
mounting or other fitting attached to such vessel which is
1. Definition. Accident. Accident means an
wholly or partly under pressure when steam is shut off.
explosion of a boiler or steam pipe or any damage to a boiler
188 POWER PLANT ENGINEERING
Economiser. Economiser means any part of a feed prescribed manner the maximum pressure, if any, at which
pipe that is wholly or partly exposed to the action of flue such boiler may be used, and shall report the result of the
gases for the purpose of recovery of waste heat. examination to the Chief Inspector in the prescribed form.
Feed pipe. Feed pipe means any pipe or connected (iv) The Chief Inspector, on receipt of the report,
fitting wholly or partly under pressure through which feed may register the boiler and assign a register number
water passes directly to a boiler and which does not form thereto either forthwith or after satisfying himself that any
an integral part thereof. structural alteration, addition or renewal which he may
Owner. Owner includes any person using a boiler deem necessary has been made in or to the boiler or any
as agent of the owner thereof and any person using a boiler steam pipe attached thereto, or (b) refuse to register the
which he has hired or obtained on load from the owner boiler :
thereof. Provided that where the Chief Inspector refuses to
Steam pipe. Steam pipe means any pipe through register a boiler, he shall forthwith communicate his refusal
which steam passes from a boiler to a primemover to other to the owner of the boiler together with the reason therefore.
user or both, if : (v) The Chief Inspector shall, on registering the
(i) the pressure at which steam passes from a boiler boiler order the issue to the owner of a certificate in the
through such pipe exceeds 3.5 kilograms per square prescribed form authorising the use of the boiler for a period
centimetre above atmospheric pressure ; or not exceeding such maximum pressure as he thinks fit,
(ii) such pipe exceeds 254 millimetres in internal and as is in accordance with the regulations made under
diameter and includes in either case any connected fitting this Act :
of a steam pipe. Provided that a certificate issued under this sub-
“Structural alterations, addition or renewal” shall section in respect of an economiser (or of an unfired boiler
not be deemed to include any renewal or replacement or a which forms an integral part of a processing plant in which
petty nature when the part or fitting used for replacement steam is generated solely by the use of oil, asphalt or
is not inferior in strength, efficiency or otherwise to the bitumen as a heating medium) may authorise its use for a
replaced part or fitting. period not exceeding 24 months.
To enforce this Act effectively, the State (vi) The Inspector shall forthwith convey to the
Governments employ Chief Inspector, Deputy Chief owner of boiler the orders of the Chief Inspector and shall
Inspectors and Inspectors. in accordance therewith issue to the owner any certificate
of which the issue has been ordered, and where the boiler
2. Prohibition of use of unregistered boilers.
has been registered, the owner shall within the prescribed
No owner of a boiler shall use the boiler or permit it to be
period cause the register number to be permanently marked
used :
there on the prescribed manner.
(a) unless it has been registered in accordance with
4. Renewal of Certificate. (i) A certificate
the provisions of this Act ;
authorising the user of a boiler shall cease to be in force :
(b) unless a certificate or provisional order
(a) on the expiry of the period for which it was
authorising use of the boiler is for the time being in force
granted ; or
under this Act.
(b) when any accident occurs to the boiler ; or
(c) in the case of any boiler which has been
transferred from one State to another until the transfer (c) when the boiler is moved : the boiler not being a
has been reported in the prescribed manner ; vertical boiler, the heating surface of which is
less than 18.58 sq. m or a portable or vehicular
(d) at a pressure higher than the maximum
boiler ;
pressure recorded in such certificate or provisional order.
(d) when any structural alteration, addition or
3. Registration. (i) The owner of any boiler which
renewal is made in or to the boiler ; or
is not registered under the provisions of this Act may apply
to the Inspector to have the boiler registered. Every such (e) if the Chief Inspector in any particular case so
application shall be accompanied by the prescribed fee. directs, when any structural alteration, addition
or renewal is made in or to any steam pipe
(ii) On receipt of an application under sub-section
attached to the boiler ; or
(a), the Inspector shall fix a date, within thirty days or
such shorter period as may be prescribed from the date of (f ) on the communication to the owner of the boiler
the receipt, for the examination of the boiler and shall give of an order of the Chief Inspector or Inspectors
the owner thereof not less than ten days’ notice of the date prohibiting its use on the ground that it or any
so fixed. steam pipe attached thereto is in a dangerous
condition.
(iii) On the said date the Inspector shall proceed to
measure and examine the boiler and to determine in the
STEAM POWER PLANT 189
(ii) Where an order is made under clause (f) of the refusal to the owner of the boiler, together with the reasons
sub-section (i), the grounds on which the order is made therefor.
shall be communicated to the owner with the order. (vii) Nothing in this section shall be deemed to
(iii) When a certificate ceases to be in force, the prevent an owner of a boiler from applying for a renewal
owner of the boiler may apply to the Inspector for a renewal certificate therefor at any time during the currency of a
thereof for such period not exceeding 12 months as he may certificate.
specify in the application ; 5. Provisional orders. Where the Inspector reports
Provided that where the certificate relates to an the case of any boiler to the Chief Inspector under above
economiser, the application for its renewal may be for a sections he may, if the boiler is not a boiler the use of which
period not exceeding 24 months. has been prohibited, grant to the owner thereof a
(iv) An application under sub-section (iii) shall be provisional order in writing permitting the boiler to be used
accompanied by the prescribed fee and, on receipt thereof, at a pressure not exceeding such maximum pressure as he
the Inspector shall fix a date, within 30 days or such shorter thinks fit and as is in accordance with the regulations made
period as may be prescribed from the date of the receipt, under this Act pending the receipt of the order of the Chief
for the examination of the boiler and shall give the owner Inspector. Such provisional order shall be cease to be in
thereof not less than 10 days’ notice of the date so fixed ; force :
Provided that, where the certificate has ceased to (i) on the expiry of 6 months from the date on which
be in force owing to the making of any structural alteration, it is granted, or
addition or renewal, the Chief Inspector may dispense with (ii) on receipt of the orders of the Chief Inspector.
the payment of any fee. 6. Use of boiler pending grant of certificate.
(v) On the said date the Inspector shall examine Notwithstanding anything hereinbefore contained, when
the boiler in the prescribed manner and if he is satisfied the period of the certificate relating to a boiler has expired,
that the boiler and the steam pipe or steam pipes attached the owner shall, provided that he has applied before the
thereto are in good condition shall issue a renewal expiry of that period for a renewal of the certificate, be
certificate authorising the use of the boiler for such period entitled to use the boiler at the maximum pressure entered
not exceeding 12 months and at a pressure not exceeding in the former certificate pending the issue of orders on the
such maximum pressure as he thinks fit and as in application.
accordance with the regulations made under this Act : 7. Revocation of certificate of provisional
Provided that a renewed certificate issued under this order. The Chief Inspector may at any time withdraw or
sub-section in respect of a economiser, may authorise its revoke any certificate or provisional order on the report of
use for a period not exceeding 24 months : an Inspector or otherwise :
Provided further that if the Inspector : (i) if there is reason to believe that the certificate
(a) proposes to issue any certificate ; or provisional order has been fraudulently obtained or has
— having validity for a less period than the been granted erroneously or without sufficient
period entered in the application, or examination ; or
— increasing or reducing the maximum pressure (ii) if the boiler in respect of which it has been
at which the boiler may be used, or granted has sustained injury or has ceased to be in good
condition ; or
(b) proposes to order any structural alteration,
addition or renewal to be made in or to the boiler (iii) where the State Government has made rules
or any steam-pipe attached thereto, or requiring that boilers shall be in charge of persons holding,
if the boiler is in charge of a person not holding the
(c) is of opinion that the boiler is not fit for use, the
certificate required by such rules ; or
Inspector shall, within 48 hours of making the
examination, inform the owner of the boiler in (iv) where no such rules have been made, if the boiler
writing of his opinion and the reasons therefor, is in charge of a person who is not, having regard to the
and shall forthwith report the case for orders to condition of the boiler, in the opinion of the Chief Inspector
the Chief Inspector. competent to have charge thereof :
(vi) The Chief Inspector, on receipt of a report under Provided that where the Chief Inspector withdraws
sub-section (5), may, subject to the provisions of this Act or revokes a certificate or provisional order on the ground
and of the regulations made hereunder, order the renewal specified in clause (iv), he shall communicate to the owner
of the certificate in such terms and on such conditions, if of the boiler his reasons in writing for the withdrawal of
any, as he thinks fit, or may refuse to renew it : revocation, and the order shall not take effect until the
expiry of thirty days from the receipt of such
Provided that where the Chief Inspector refuses to
communication.
renew a certificate, he shall forthwith communicate his
190 POWER PLANT ENGINEERING
8. Alterations and renewals to boilers. No 14. Report of accidents. (i) If any accident occurs
structural alteration, addition or renewal shall be made in to a boiler or steam pipe, the owner or person incharge
or to any boiler registered under this Act unless such thereof shall, within 24 hours of the accident, report the
alterations, additions or renewals have been sanctioned in same in writing to the Inspector. Every such report shall
writing by the Chief Inspector. contain a true description of the nature of the accident and
9. Alterations and renewals to steam pipes. of the injury, if any, caused thereby to the boiler or to the
Before the owner of any boiler registered under this Act steam pipe or to any person and shall be in sufficient detail
makes any structural alteration, addition or renewal in or to enable the Inspector to judge the gravity of the accident.
to any steam pipe attached to the boiler, he shall transmit (ii) Every person shall be bound to answer truly to
to the Chief Inspector a report in writing of his intention, the best of his knowledge and ability every question put to
and shall send therewith such particulars of the proposed him in writing by the Inspector as to the cause, nature or
alteration, addition or renewal as may be prescribed. extent of his accident.
10. Duty of the owner at examination. (i) On 15. Minor Penalties. Any owner of a boiler who
any date fixed under this Act for the examination of the refuses or without reasonable excuse neglects :
boiler, the owner thereof shall be bound : (i) to surrender a provisional order as required,
(a) to afford to the Inspector all reasonable facilities (ii) to produce a certificate or provisional order when
for the examination and all such information as may duly called upon to do so,
reasonably be required of him ; (iii) to make over to the new owner of a boiler a
(b) to have the boiler properly prepared and ready certificate or provisional order as required shall be
for examination in the prescribed manner ; and punishable with fine which may extend to one hundred
(c) in the case of an application for the registration rupees.
of a boiler, to provide such drawings, specifications, 16. Penalties for illegal use of boiler. Any owner
certificates and other particulars as may be prescribed. of a boiler who, in any case in which a certificate or
(ii) If the owner fails, without reasonable cause, to provisional order is required for the use of the boiler under
comply with the provisions of the sub-section (i), the this Act, uses the boiler either without any such certificate
Inspector shall refuse to make the examination and shall or provisional order being in force or at a higher pressure
report the case to the Chief Inspector who shall, unless than that allowed thereby, shall be punishable with fine
sufficient cause to the contrary is shown, require the owner which may extend to ` 500 and, in the case of a continuing
to file a fresh application, and may forbid him to use the offence, with an additional fine which may extend to one
boiler notwithstanding any thing contained in section (F). hundred rupees for each day after the first day in regard
11. Production of certificates, etc. The owner of to which he is convicted of having persisted in the offence.
any boiler who holds a certificate or provisional order 17. Other Penalties. Any person who
relating thereto shall, at all reasonable times during the (i) uses or permits to be used a boiler of which he is
period for which the certificate or order is in force, be bound the owner and which has been transferred from one State
to produce the same when called upon to do so by a District to another without such transfer having been reported as
Magistrate, Commissioner of Police or Magistrate of the required ;
first class having jurisdiction in the area in which the boiler (ii) being the owner of a boiler fails to cause the
is, for the time being, or by the Chief Inspector or by any register number allotted to the boiler under this Act to be
Inspector appointed under the Indian Factories Act, or by marked on the boiler as required ;
any person specially authorised in writing by a District
(iii) makes any structural alteration, addition or
Magistrate or Commissioner of Police.
renewal in or to a boiler without first obtaining the sanction
12. Transfer of certificate, etc. If any person of the Chief Inspector when so required, or to a steam pipe
becomes the owner of a boiler during the period for which without first informing the Chief Inspector when so
a certificate or provisional order relating thereto is in force, required ;
the preceding owner shall be bound to make over to him
(iv) fails to report an accident to a boiler or steam
the certificate or provisional order.
pipe when so required.
13. Power of entry. An Inspector may, for the
(v) tampers with a safety valve of a boiler so as to
purpose of inspecting or examining a boiler or any steam
render it inoperative at the maximum pressure at which
pipe attached there to or of seeing that any provision of
the use of the boiler is authorised under this Act.
this Act or of any regulation or rule made hereunder has
been or is being observed, at all reasonable times, enter 18. Penalty for tampering with registered
any place or building within the limits of the area for which mark. (i) Whoever removes, alters, defaces, renders
he has been appointed in which he has reason to believe invisible or otherwise tampers with the register number
that a boiler is in use. marked on a boiler in accordance with the provision of this
STEAM POWER PLANT 191
Act or any Act repealed hereby, shall be punishable with this Act or any Act repealed hereby, shall be punishable
fine which may extend to five hundred rupees. with imprisonment which may extend to 2 years, or with
(ii) Whoever fraudulently marks upon a boiler a fine, or with both.
register number which has not been allotted to it under
Example 3.37. The following data relate to a regenerative Neglecting the pump work in calculating the input
steam power plant generating 22500 kW energy, the to the boiler, determine :
alternator directly coupled to steam turbine : (i) The steam bled per kg of steam supplied to the
Condition of steam supplied to the steam turbine turbine.
... 60 bar, 450°C (ii) The steam generated per hour if the 9 per cent of
Condenser vacuum ... 707.5 mm the generator output is used to run the pumps.
Pressure at which steam is bled from the steam turbine (iii) The overall efficiency of the plant.
... 3 bar Solution. The schematic arrangement of the steam power
Turbine efficiency of each portion of expansion plant is shown in Fig. 3.151 (a), while the conditions of the
... 87 per cent fluid passing through the components are represented on
Boiler efficiency ... 86 per cent T-s and h-s diagrams as shown in Fig. 3.151 (b) and (c).
Alternator efficiency ... 94 per cent The conditions of the fluid entering and leaving the pump
Mechanical efficiency from turbine to generator are shown by the same point as the rise in temperature
... 97 per cent due to pump work is neglected.
60 bar, 450°C
3-f supply
1
ü
ý
þ
1 kg
Turbine
2¢
0.07 bar Alternator
Boiler
(1–m) kg
3 bar m kg
3¢
In
Feed 4 Water
heater 4 Out
Condenser
5 Pump 5 Pump
(a) Schematic arrangement of the steam power plant
T h 60 bar
1 (60 bar, 450°C) 1
h1
60 bar 3 bar
2¢
h 2¢
2¢ 0.07 bar
h2
2¢ 2 Sa
5 t. c
2 h 3¢ urv
3¢ e
4 h3
3 3¢ 3
s s
(b) T-s diagram (Neglecting pump work) (c) h-s diagram
Fig. 3.151
192 POWER PLANT ENGINEERING
Superheater Reheater
1 80 bar 7 bar
3
(1–m) kg
H.P. L.P.
2
Boiler
7 bar 4
1 kg
m kg Condenser
(1–m) kg
2
80 bar 7 bar
h (kJ/kg)
80 bar 7 bar
0.4 bar
350°C
3170
1 3
2985
(1–m) kg
1 kg
2555
2520
2
s (kJ/kg K)
(b) h-s diagram
Fig. 3.152
Also, from steam tables, we have : (ii) The boiler generating capacity :
hf 2 (at 7 bar) = 697.1 kJ/kg ; hf4 (at 0.4 bar) If ms is the mass of steam supplied to the power
= 317.7 kJ/kg plant per second, then the work developed is given by :
ms(h1 – h2) + ms(1 – m) (h3 – h4) = 110 × 103
(i) The ratio of steam bled to steam generated :
or ms(2985 – 2520) + ms(1 – 0.172) (3170 – 2555)
Consider energy/heat balance of feed heater :
= 110 × 103
Heat lost by m kg of steam = Heat gained by (1 – m)
kg of condensed steam or ms(465 + 509.22) = 110 × 103
m(h2 – hf 2 ) = (1 – m) (hf2 – hf4) ms = 112.91 kg/s or
m(2520 – 697.1) = (1 – m) (697.1 – 317.7) 406.48 tonnes/hour (Ans.)
1822.9 m = (1 – m) × 379.4 (iii) Thermal efficiency of the cycle, thermal :
m = 0.172 kg Output / kg of steam
i.e., Amount of steam bled per kg of steam supplied to the thermal =
Input / kg of steam
turbine = 0.172 kg
(h1 h2 ) (1 m) (h3 h4 )
Steam generated 1 =
(h1 hf2 ) (1 m) (h3 h2 )
Steam bled 0.172
= 5.814. (Ans.)
194 POWER PLANT ENGINEERING
(2985 2520) (1 0.172) steam is reheated to 350°C in a reheater and then expanded
(3170 2555) in L.P. turbine down to 0.035 bar. Determine :
=
(2985 697.1) (1 0.172) (i)
Amount of steam bled-off for feed heating,
(3170 2520) (ii)
Amount of steam supplied to L.P. turbine,
(iii)
Heat supplied in the boiler and reheater,
974.22
= (iv)
Cycle efficiency, and
2826.1
= 0.3447 or 34.47%. (Ans.) (v)
Power developed by the system.
The steam supplied by the boiler is 50 kg/s.
Example 3.39. A steam power plant equipped with
(B.U.)
regenerative as well as reheat arrangement is supplied with
steam to the H.P. turbine at 80 bar 470°C. For feed heating, Solution. The schematic arrangement is the steam power
a part of steam is extracted at 7 bar and remainder of the plant of shown in Fig. 3.153 (a) and the processes are
represented on h-s diagram as shown in Fig. 3.153 (b).
Superheater
80 bar, Reheater
470°C 3-f supply
1 1 kg
ü
ý
þ
(1–m) kg 3
h 80 bar
7 bar
H.P. L.P. h1 1 470°C
Boiler 3 350°C
Alternator h3
4 0.035 bar 0.035 bar
1 kg
(1–m) kg h2
80 bar m kg 2 2
7 bar h4
Condenser 4
6 6 5 5
s
(b) h-s diagram
(1–m) kg
Regenerator
(a) Schematic arrangement of the steam power plant
Fig. 3.153
From h-s chart and steam tables, we have enthalpies Hence amount of steam bled off is 22.5% of steam
at different points as follows : generated by the boiler. (Ans.)
h1 = 3315 kJ/kg ; h2 = 2716 kJ/kg UV (ii) Amount of steam supplied to L.P. turbine :
h3 = 3165 kJ/kg ; h4 = 2236 kJ/kg W Amount of steam supplied to L.P. turbine
From h-s chart = 100 – 22.5
hf 6 = hf 2 = 697.1 kJ/kg ; = 77.5% of the steam generated by the
hf 5 = hf 4 = 101.9 kJ/kg } From steam table. boiler. (Ans.)
(i) Amount of steam bled off for feed heating : (iii) Heat supplied in the boiler and reheater :
Considering energy balance at regenerator, we have : Heat supplied in the boiler per kg of steam generated
Heat lost by steam = Heat gained by water = h1 – hf6 = 3315 – 697.1
m(h2 – hf 6) = (1 – m) (hf 6 – hf 5) = 2617.9 kJ/kg. (Ans.) (∵ hf6 = hf2)
or m(h2 – hf 2) = (1 – m) (hf 2 – hf 4) Heat supplied in the reheater per kg of steam
[∵ hf 6 = hf 2 ; hf 5 = hf 4] generated
or m(2716 – 697.1) = (1 – m) (697.1 – 111.9) = (1 – m) (h3 – h2)
or 2018.9 m = 585.2 (1 – m) = (1 – 0.225) (3165 – 2716)
m = 0.225 g of steam supplied = 347.97 kJ/kg. (Ans.)
STEAM POWER PLANT 195
Total amount of heat supplied by the boiler and Solution. The arrangement of the components is shown
reheater per kg of steam generated, in Fig. 3.154 (a) and the processes are represented on T-s
Qs = 2617.9 + 347.97 = 2965.87 kJ/kg diagram as shown in Fig. 3.154 (b).
From h-s chart and steam tables we have enthalpies
(iv) Cycle efficiency, cycle : at different points as follows :
Amount of work done by per kg of steam generated
by the boiler, h1 = 3578 kJ/kg ; h2 = 3140 kJ/kg ; UV
W = 1(h1 – h2) + (1 – m) (h3 – h4),
h3 = 3678 kJ/kg ; h4 = 3000 kJ/kg ; W
Neglecting pump work h5 = 2330 kJ/kg ; From h-s chart
= (3315 – 2716) + (1 – 0.225) (3165 – 2236) hf1 (at 150 bar) = 1611 kJ/kg
~ hf 2 (at 40 bar) = 1087.4 kJ/kg ;
1319 kJ/kg
W 1319
hf4 (at 5 bar) = 640.1 kJ/kg ; UV
cycle =
Qs 2965.87
hf 5 = hf 6 (at 0.1 bar) = 191.8 kJ/kg W
Steam tables
= 0.4447 or 44.47% (Ans.)
(i) Fraction of steam extracted from the
(v) Power developed by the system : turbines at each bled heater m1, m2 :
Power developed by the system Considering energy balance for closed feed heater,
50 1319 we have :
= ms × W = 50 × 1319 kJ/s =
1000 m1(h2 – hf 2) = (1 – m1) (hf2 – hf4)
= 65.95 MW (Ans.) m1(3140 – 1087.4) = (1 – m1)(1087.4 – 640.1)
Example 3.40. A steam power plant operates on ideal or, 2052.6 m1 = (1 – m1) × 447.3
Rankine cycle using reheater and regenerative feed water
m1 = 0.179 kg/kg of steam
heaters. It has one open feed heater. Steam is supplied at
supplied by the boiler.
150 bar and 600°C. The condenser pressure is 0.1 bar. Some
steam is extracted from the turbine at 40 bar for closed feed (Ans.)
water heater and remaining steam is reduced at 40 bar to Considering energy balance for open feed heater, we
600°C. Extracted steam is completely condensed in this have :
closed feed water heater and is pumped to 150 bar before m2(h4 – hf4) = (1 – m1 – m2)(hf4 – hf6)
mixing with the feed water heater. Steam for the open feed or, m2(h4 – hf4) = (1 – m1 – m2)(hf4 – hf5)
water heater is bled from L.P. turbine at 5 bar. Determine : (∵ hf 6 = hf 5)
(i) Fraction of steam extracted from the turbines at or, m2(3000 – 640.1) = (1 – 0.179 – m2) (640.1 – 191.8)
each bled heater, and or, 2359.9 m2 = (0.821 – m2) × 448.3
(ii) Thermal efficiency of the system. = 368.05 – 448.3 m2
Draw the line diagram of the components and m2 = 0.131 kg/kg of steam
represent the cycle on T-s diagram. (P.U.) supplied by boiler. (Ans.)
Superheater
(1–m1) kg Reheater
3-f supply
1 150 bar
ü
ý
þ
2 40 bar 3
(1–m1) kg 40 bar
H.P. L.P.
Boiler
4 m2 kg Alternator
40 bar m1 (1–m –m
1 kg 5 1 2) kg
5 bar 0.1 bar
150 bar Closed feed
2
heater
(1–m1)
(1–m1–m2) kg
40 bar
5 bar 6
g
h1 Heat supplied by the boiler per kg of steam,
)k
(1–m1) kg
1
–m
(1 Qs1 = h1 – 1610 = 3578 – 1610 = 1968 kJ/kg
5 bar Qs2 = Heat supplied in the reheater
h2 2 = (1 – m1)(h3 – h2)
4 (1–m1–m2) kg
h4 = (1 – 0.179)(3678 – 3140)
0.1 bar
= 441.7 kJ/kg of steam supplied by the
boiler
h5
5 Qst (Total heat supplied)
s = Qs1 + Qs2 = 1968 + 441.7 = 2409.7 kJ/kg
(b) h-s diagram Wnet 1442.73
thermal =
Qst 2409.7
Fig. 3.154 = 0.5987 or 59.87%. (Ans.)
(ii) Thermal efficiency of the system, thermal : Example 3.41. Steam at 70 bar and 450°C is supplied to a
Total work done per kg of steam supplied by the steam turbine. After expanding to 25 bar in high pressure
boiler stages, it is reheated to 420°C at the constant pressure. Next ;
= 1 × (h1 – h2) + (1 – m1)(h3 – h4) it is expanded in intermediate pressure stages to an
appropriate minimum pressure such that part of the steam
+ (1 – m1 – m2)(h4 – h5)
bled at this pressure heats the feed water to a temperature
= (3578 – 3140) + (1 – 0.179)(3678 – 3000) of 180°C. The remaining steam expands from this pressure
+ (1 – 0.179 – 0.131)(3000 – 2330) to a condenser pressure of 0.07 bar in the low pressure stage.
= 438 + 556.64 + 462.3 = 1456.94 kJ/kg The isentropic efficiency of H.P. stage is 78.5%, while that
Work done by the pump P1 of the intermediate and L.P. stages is 83% each. From the
above data, determine :
WP1 = vw1 (1 – m1 – m2)(5 – 0.1) × 105
× 10–3 kJ/kg (i) The minimum pressure at which bleeding is
necessary.
1
= (1 – 0.179 – 0.131)(5 – 0.1) × 105 (ii) The quantity of steam bled per kg of flow at the
1000 turbine inlet.
× 10–3 = 0.338 kJ/kg
(iii) The cycle efficiency.
LMTaking v 1
m3 /kg
OP Neglect pump work. (Roorkee University)
N w1 vw2 vw3
1000 Q Solution. The schematic arrangement of the plant is
Work done by the pump P2, shown in Fig. 3.155 (a) and the processes are represented
WP2 = vw2 (1 – m1)(150 – 5) × 105 × 10–3 kJ/kg on T-s and h-s diagrams as shown in Fig. 3.155 (b) and (c)
1 respectively.
= (1 – 0.179)(150 – 5) × 105 × 10 – 3
1000 (i) The minimum pressure at which bleeding
= 11.9 kJ/kg is necessary :
Work done by pump P3, It would be assumed that the feed water heater is
WP3 = vw3 × m1 × (150 – 40) × 105 × 10 – 3 an open heater. Feed water is heated to 180°C. So psat at
1 180°C ~
10 bar is the pressure at which the heater operates.
= × 0.179 (150 – 40) × 105 × 10–3 Thus, the pressure at which bleeding is necessary is
1000
= 1.97 kJ/kg 10 bar. (Ans.)
Total pump work From the h-s chart (Mollier chart), we have :
= WP1 + WP2 + WP3 h1 = 3285 kJ/kg ; h2 = 2980 kJ/kg ;
= 0.338 + 11.9 + 1.97
h3 = 3280 kJ/kg ; h4 = 3030 kJ/kg
= 14.21 kJ/kg of steam supplied by boiler
h3 – h4 = 0.83(h3 – h4) = 0.83(3280 – 3030)
Net work done by the turbine per kg of steam
supplied by the boiler, = 207.5 kJ/kg
Wnet = 1456.94 – 14.21 = 1442.73 kJ/kg h4 = h3 – 207.5 = 3280 – 207.5
= 3072.5 kJ/kg
STEAM POWER PLANT 197
Superheater
70 bar,
1 kg 450°C Reheater
1 kg 3-f supply
1 25 bar,
ü
ý
þ
2 1 kg 3 420°C
70 bar
T h 25 bar
1 (470°C) 3 (420°C)
1 3
10 bar
70 bar
1 kg 2¢ 2 2¢ 0.07 bar
25 bar
2 4¢
4¢ 4
9 4
m kg
8
7 10 bar
(1–m) kg
6 5¢
0.07 bar 5 5¢
s 5 s
(b) T-s diagram (c) h-s diagram (Pump work not shown)
Fig. 3.155
(ii) The quantity of steam bled per kg of flow = 0.206 g of steam flow at turbine
at the turbine inlet, m : inlet. (Ans.)
Considering energy balance for the feed water heater, (iii) Cycle efficiency, cycle :
we have : Work done
m × h4 + (1 – m) hf7 = 1 × hf8 cycle =
Heat supplied
m × 3072.5 + (1 – m) × 163.4 = 1 × 762.6
(∵ hf7 = hf6) 1(h1 h2 ) 1(h3 h4 )
3072.5 m + 163.4 – 163.4 m = 762.6 (1 m)(h4 h5 )
=
(762.6 163.4) (h1 hf 8 ) (h3 h2 )
m=
(3072.5 163.4)
198 POWER PLANT ENGINEERING
(3285 3045.6) 207.5 (i) Sketch the feed heating system and show the
(1 0.206)(715.9) process on T-s and h-s diagrams.
= (ii) Amounts of steam bled off.
(3285 762.6) (3280 3045.6)
(iii) Overall thermal efficiency of turbo-alternator
1015.3 considering pump work.
=
2756.8 (iv) Specific steam consumption is kg/kWh.
= 0.3683 or 36.83%. (Ans.) (AMIE)
Example 3.42. A steam turbine plant developing 120 MW Solution. (i) The schematic arrangement including feed
of electrical output is equipped with reheating and heating system is shown in Fig. 3.156 (a), and T-s and h-s
regenerative feed heating arrangement consisting of two feed diagrams of the process are shown in Fig. 3.156 (b) and (c)
heaters—one surface type on H.P. side and other direct respectively.
contact typed on L.P. side. The steam conditions before the (ii) Amounts of bled off. The enthalpies at various
steam stop valve are 100 bar and 530°C. A pressure drop of state points as read from h-s diagram/steam tables, in
5 bar takes place due to throttling in valves. kJ/kg, are :
Steam exhausts from the H.P. turbine at 25 bar. A h1 = h2 = 3460 kJ/kg
small quantity of steam is bled off at 25 bar for H.P. surface h3 = 3050, and
heater for feed heating and the remaining is reheated in a h3= 3460 – 0.85(3460 – 3050) = 3111.5
reheater to 550° C and the steam enters at 22 bar in L.P. h4 = 3385
turbine for further expansion. Another small quantity of
h5 = 3140, and
steam is bled off at pressure 6 bar for the L.P heater and
the rest of steam expands up to the back pressure of 0.05 h5 = 3585 – 0.85(3585 – 3140) = 3207
bar. The drain from the H.P. heater is led to the L.P. heater h6= 2335, and
and the combined feed from the L.P. heater is pumped to h6 = 3207 – 0.85 (3207 – 2335) = 2466
the high-pressure feed heater and finally to the boiler with h7 = 137.8 kJ/kg (hf at 0.05 bar)
the help of boiler feed pump. h8 = h10 = 962 kJ/kg (hf at 25 bar)
The component efficiencies are: turbine efficiency and, h9 = 670.4 kJ/kg (hf at 6 bar).
85%, pump efficiency 90%, generator efficiency 96%, boiler Enthalpy balance for surface heater :
efficiency 90% and mechanical efficiency 95%. It may be m1h3 + h9 = m1h8 + h10, neglecting pump work
assumed that the feed water is heated up to the saturation
h10 h9 962 670.4
temperature at the prevailing pressure in feed heater. Work or, m1 = = 0.13566 kg
out the following : h3 h8 3111.5 962
STEAM POWER PLANT 199
ba bar ar
25 95 0 b
h r T
ba
10
0 ar 1
r
0
ba
1 5b r
r
9 ba r
22
2
1 2 25 2 ba 3¢ 4
3¢ 2 ar 3
r
6b
ba
3 4
ar
6
5¢
5¢ 5b
r
ba
5 0 . 0 5
05
0.
6 6¢
6¢
6
s s
(b) (c)
Fig. 3.156
Enthalpy balance for contact heater : Amounts of bled off are :
m2h5 + (1 – m1 – m2) h7 + m1h8 = h9, (a) Surface (high pressure) heater,
neglecting pump work = 0.13566 kg/kg or boiler flow
or m2 × 3207 + (1 – 0.13566 – m2) × 137.8 or = 0.13566 × 4.155 × 105
+ 0.13566 × 962 = 670.4 i.e., = 5.6367 × 104 kg/h. (Ans.)
or m2 = 0.1371 kg.
(b) Direct contact (low pressure) heater
Pump Work. The specific volume of water as 0.001
= 0.1371 kg/kg of boiler flow
m3/kg.
or = 0.1371 × 4.155 × 105
(Wpump)L.P. = (1 – m1 – m2)(6 – 0.05) × 0.001 × 102
i.e., = 5.697 × 104 kg/h. (Ans.)
= (1 – 0.13566 – 0.1371) × 5.95 × 0.1
(iii) Overall thermal efficiency, overall :
= 0.4327 kJ/kg.
(c) Heat input in boiler
(Wpump)H.P. = 1 × (100 – 6) × 0.001 × 102
h1 h10 3460 962
= 9.4 kJ/kg =
boiler 0.9
Total pump work (actual)
= 2775.6 kJ/kg of the boiler flow.
0.4327 9.4 Heat input in reheater
= = 10.925 kJ/kg
0.9 h h3 3585 3111.5
Turbine output (indicated) = 4
boiler 0.9
= (h2 – h3) + (1 – m1)(h4 – h5) = 526.1 kJ/kg of boiler flow
+ (1 – m1 – m2)(h5 – h6)
1039.55
= (3460 – 3111.5) overall = × 100
2775.6 526.1
+ (1 – 0.13566) (3585 – 3207) = 31.48%. (Ans.)
+ (1 – 0.13566 – 0.1371)(3207 – 2466) (iv) Specific steam consumption.
= 1214.105 kJ/kg Specific steam consumption
Net electrical output 4.155 105
= (Indicated work – pump work) ×mech. =
120 103
× gen. = 3.4625 kg/kWh. (Ans.)
= (1214.105 – 10.925) × 0.9 × 0.96 Example 3.43. (a) How does erosion of turbine blades
= 1039.55 kJ/kg occur ? State the methods of preventing erosion of turbine
[Note. All the above calculations are for 1 kg of main blades.
(boiler) flow.] (b) What do you mean by TTD of a feed water heater ?
Main steam flow rate Draw temperature-path-line diagram of a closed feed water
120 103 3600 heater used in regenerative feed heating cycle.
= = 4.155 × 105 kJ/h. (c) In a 15 MW steam power plant operating on ideal
1039.55
reheat cycle, steam enters the H.P. turbine at 150 bar and
200 POWER PLANT ENGINEERING
Temp.
the blades. Such impact, if sufficiently heavy, produces
severe local stresses in the blade material causing the surface
Path line
metal to fail and flake off.
The erosion, if any, is more likely to occur in the Fig. 3.158
region where the stem is wettest. i.e., in the last one or two
Moisture contents in exit from L.P. turbine = 10.4%
stages of the turbine. Moreover, the water droplets are
x4 = 1 – 0.104 = 0.896
concentrated in the outer parts of the flow annuals where
the velocity of impact is highest.
T
1
h 3
150 bar
1 3 T = const.
g
tin
a
e he 40 bar
R 2
Sa 5
t. c
2 urv
e 0.1 bar
Condenser 5¢ 4
pressure s
4
Fig. 3.159
s h
r
Fig. 3.157 ba
0
15 3
Erosion difficulaties due to moisture in the steam 1 600°C
may be avoided by reheating (see Fig. 3.157). The whole of
steam is taken from the turbine at a suitable point 2, and
a further supply of heat is given to its along 2-3 after which
the steam is readmitted to the turbine and expanded along r
ba
3-4 to condenser pressure. 2 0.1
Erosion may also be reduced by using steam traps x=
0.8
4
in between the stages to separate moisture from the steam. 9 6
(b) TTD means terminal temperature difference. It s
is the difference between temperatures of bled steam/
condensate and the feed water at the two ends of the feed Fig. 3.160
water heater. (i) Reheat pressure : From the Mollier diagram,
The required temperature-path-line diagram of a the reheat pressure is 40 bar. (Ans)
closed feed water heater is shown in Fig. 3.158. (ii) Thermal efficiency, th :
(c) The cycle is shown on T-s (Fig. 3.159) and h-s Turbine work = (h1 – h2) + (h3 – h4)
(Fig. 3.160) diagrams. The following values are read from = (3580 – 3140) + (3675 – 2335)
the Mollier diagram. = 1780 kJ/kg.
h1 = 3580 kJ/kg, h2 = 3140 kJ/kg, Assuming specific volume of water
h3 = 3675 kJ/kg, and h4 = 2335 kJ/kg = 10–3 m3/kg, the pump work
= 10–3 (150 – 0.1) = 0.15 kJ/kg,
STEAM POWER PLANT 201
i.e., may be neglected in computing of th, (b) In impulse turbines there is no expansion of
h5 = h4 = 191.8 kJ/kg, (hf at 0.1 bar) from steam in moving blades, and the pressure of steam remains
steam tables constant while flowing over the moving blades. The
Qinput = (h1 – h5) + (h3 – h2) expansion takes place only in the nozzles at the inlet to
the turbine in HP stages, or through the fixed blades in
= (3580 – 191.8) + (3675 – 3140)
the subsequent stages. The nozzles need not occupy the
= 3923.2 kJ/kg complete circumference. Therefore partial admission of
1780 steam is feasible and adopted for HP impulse stages.
%th = × 100 = 45.37%. (Ans.)
3923.2 In reaction turbines, pressure drop is required in
(iii) Specific steam consumption : the moving blades also. This is not possible with partial
Steam consumption admission. Hence full admission is essential for all stages
of a reaction turbine.
15 103
= = 8.427 kg/s (c) Refer to Fig. 3.96
1780
Specific steam consumption Given : N = 3000 r.p.m. ; = = 20° ;
8.427 3600 Cbl
= Cbl = 120 m/s ; = 0.8 ;
15 103 C1
= 2.0225 kg/kWh. (Ans.) Cbl 120
C1 = = 150 m/s
(iv) Rate of pump work : 0.8 0.8
Rate of pump work DN DN
= 8.427 × 0.15 = 1.26 kW. (Ans.) Also, Cbl = or 120 =
60 60
Example 3.44. (a) Why is drum type construction preferred 120 60
to disc type construction in reaction turbine ? D= = 0.764 m.
3000
(b) Why is partial admission of steam adopted for
H.P. impulse stages while full admission is essential for From steam tables, vg (at 2.7 bar) = 0.668 m3/kg
any stage of a reaction turbine ? v = 0.95 × 0.668 = 0.6346 m3/kg
(c) In a 50% reaction turbine, the speed of rotation 30
of a blade group is 3000 rpm with mean blade velocity of Flow area A = Dh = × 0.764 × = 0.072 m2
1000
120 m/s. The velocity ratio is 0.8 and the exit angle of the
Flow velocity,
blades is 20°. It the mean blade height is 30 mm, calculate
the total steam flow rate through the turbine. Neglect the Cf = C1 sin = 150 sin 20° = 51.3 m/s
effect of blade edge thickness of the annular area but (Cf1 Cf0 Cf )
consider 10% of the total steam flow rate as the tip leakage ACf 0.072 51.3
loss. The mean condition of steam in that blade group is Mass flow rate, m =
v 0.6346
found to be 2.7 bar and 0.95 dry.
= 5.82 kg/s
(d) What do you mean by once through boiler ?
(AMIE) Accounting for 10 per cent leakage (of total steam
flow), the total steam flow rate is
Solution. (a) The rotor of the turbine can be of drum type
or disc type. Disc type construction is difficult (complicated) 5.82
to make, but lighter in weight. Hence the centrifugal = 6.467 kg/s. (Ans.)
0.9
stresses are lower at a particular speed. On the other hand (d) Once through boiler is a boiler which does not
drum type construction is simple in construction, and it is require any water or steam drum. It is a monotube boiler
easy to attach aerofoil shape blades. Further it is easier to using a long tube arranged in the combustion chamber and
design for tip leakage reduction which is a major problem the furnace. The economizer, boiler and superheater are in
in reaction turbines. Moreover due to small pressure drop series with no fixed surfaces as separators between the steam
per stage (larger number of stages) in reaction turbines, and water.
their rotational speeds are lower and so the centrifugal Benson boiler is an example of once through boiler,
stresses are not very high (even the reaction blades are operating at supercritical pressure. The tube length to
lighter). Therefore drum type construction is preferred to diameter ratio of such a boiler is about 2500. Due to large
disc type in reaction turbines. frictional resistance the feed pressure should be about 1.4
To accommodate increase in specific volume at lower times the boiler pressure.
pressures the drum diameter is stepped up which allows Example 3.45. (a) List the advantages of steam turbines
greater area without unduly increasing blade height. The over gas turbines.
increased drum diameter also increases the torque due to
steam pressure.
202 POWER PLANT ENGINEERING
w
Cooling water rate, m Partial pressure of steam at inlet, at 40°C
= 7.38 kPa.
202.429 (2332.6 151)
= Total condenser pressure
4.187 10
= 7.38 + 0.0216 = 7.406 kPa
= 10547.4 kg/s = 10547.4 kl/s. (Ans.)
Partial pressure of steam at pump inlet (at 32°C)
= 4.76 kPa
r
h ba
Partial pressure of air at pump suction,
0
10
1 500°C
pa2 = 7.406 – 4.76 = 2.646 kPa.
r Dry air pump capacity,
ba
67 ma RT2 16 287 (273 32)
06 V2 = =
0. pa2 vol 60 (2.646 103 ) 0.8
2¢
2
= 11.03 m3. (Ans.)
s (c) The total pressure in the condenser is the sum
of partial pressures of water vapour and air. It remains
Fig. 3.161 constant at every section of the condenser, whereas the
partial pressure of steam depends upon the temperature at
Steam that section.
In the condenser, air cooling section is provided near
40°C the air extraction pump suction. By circulating relatively
cold water at this section the temperature is kept low,
thereby lowering the partial pressure of steam. This serves
32°C two functions :
Air (i) This amount of steam lost to atmosphere (which
extraction
is otherwise used as pure condensate for boiler feed) is
considerably reduced.
35°C (ii) The partial pressure of air in this section
Condensate becomes considerably high, and so its density. For a given
rate of air leakage into the condenser, the volume of air
Fig. 3.162 handled by the air-extraction pump is reduced. This enables
(b) Specific volume of steam at inlet = xvg the use of a small capacity and power pump.
Example 3.47. A surface condenser with separate air pump
(∵ vg = 19.52 m3/kg at 40°C)
for removing the air only and providing separate air-cooling
= 0.85 × 19.52 = 16.59 m3/kg section is designed to condense 20 tonnes of steam per hour.
Volume rate of steam at inlet, The air leakage per hour is 6 kg. The temperature of the
condensate is 36°C and temperature near the suction of air
4000 16.59 pump is 28°C. The steam enters into the condenser at 39°C
V1 = = 1106 m3/min.
60 and dry-saturated condition. Find :
This is also the volume rate of air at inlet. (i) Percentage reduction in air-pump capacity due
to separate air-cooling section.
Partial pressure of air at inlet,
(ii) Minimum quantity of cooling water if the rise in
ma RT1 temperature is limited to 15°C.
pa1 =
V1 (iii) Saving in the condensate and heat supply in the
boiler per hour due to incorporation of air cooling section.
16 287 (273 40) The loss of condensation is made up with water at
= × 10–3 kPa
60 1106 15°C. (P.U.)
= 0.0216 kPa
204 POWER PLANT ENGINEERING
HIGHLIGHTS
1. A steam power plant converts the chemical energy of the 14. Natural draught is obtained by the use of a chimney.
fossil fuels (coal, oil, gas) into mechanical/electrical energy. The draught produced by the chimney is due to density
2. The layout of a modern steam power plant comprises of difference between the column of hot gases inside the
the following four circuits : chimney and the cold air outside.
(i) Coal and ash circuit
(ii) Ash and gas circuit LM 1 1 F ma 1I OP
(iii) Feed water and steam flow circuit
(iv) Cooling water circuit.
hw 353 H
MN Ta Tg GH ma JK PQ .
3. The choice of steam conditions depends upon the The draught pressure produced by the natural draught
following : system in height of hot gases column,
(i) Price of a the coal LMF ma I Tg 1OP .
MNGH ma 1JK Ta PQ
(ii) Capital cost of the plant H1 H
(iii) Time available for erection
15. Diameter (D) of the chimney is given by,
(iv) Thermal efficiency obtainable
(v) The station ‘load factor’. mg
D = 1.128
4. Automatic stokers are classified as follows : g . C
(i) Overfeed stokers (ii) Underfeed stokers. where m g = mass of gases flowing through any cross-
5. Pulverised fuel handling systems are classified as :
section of the chimney
(i) Unit system (ii) Central system.
g = density of gases
6. Pulverised fuel burners are classified as follows :
C = velocity of gases passing through the
(i) Long flame burners (ii) Turbulent burners
chimney.
(iii) Tangential burners (iv) Cyclone burners.
16. Condition for maximum discharge through a chimney is :
7. Oil burners are classified as follows :
Tg F ma 1I .
1. Vapourising oil burners :
(a) Atmospheric pressure atomising burner Ta
2 GH ma JK
(b) Rotating cup burner H LMF ma I Tg 1OP
(c) Recirculating burner
(d) Wick type burner. 17. Efficiency of chimney, chimney =
J MNGH ma 1JK Ta PQ
2. Atomising fuel burners : c p (T T )
(a) Mechanical or oil pressure atomising burner where T = absolute temperature of flue gases leaving
(b) Steam or high pressure atomising burner the chimney to create the draught of hw mm
(c) Low pressure air atomising burner. of water
8. Fluidised bed may be defined as the bed of solid particles T = absolute temperature of flue leaving the
behaving as a fluid. chimney in case of artificial draught of
9. Ash handling systems may be classified as follows : hw mm of water.
(i) Mechanical handling system 18. Power required to drive fan :
(ii) Hydraulic system F hVa ma MTa I kW
(iii) Pneumatic system Power of F.D. fan = 0.998 × 10–8 GH f JK
(iv) Steam jet system.
F hVa ma MTg I kW.
10. The dust collectors may be classified as follows :
1. Mechanical just collectors
Power of I.D. fan = 0.998 × 10–8 GH f JK
(i) Wet type (scrubbers) : (a) Spray type ; 19. A ‘boiler’ is defined as a closed vessel in which steam is
(b) Packed type ; (c) Impingement type. produced from water by combination of fuel.
(ii) Dry type : (a) Gravitational separators ; 20. Heated feed water enables steam generators to produce
(b) Cyclone separators. more kg of steam and avoids severe thermal stressing by
2. Electrical dust collectors cold water entering a hot drum.
(i) Rod type (ii) Plate type. 21. ‘Equivalent evaporation’ may be defined as the amount of
11. The ‘collection efficiency’ of a dust collector is the amount water evaporated from water at 100°C to dry and
of dust removed per unit weight of dust. saturated steam at 100°C.
12. pH value of water is the logarithm of the reciprocal of 22. A steam nozzle may be defined as a passage of varying
hydrogen ion concentration. It is number from 0 to 14 with cross-section, through which heat energy of steam is
7 indicating neutral number. converted to kinetic energy.
13. The small pressure difference which causes a flow of gas 23. The velocity, C = 44.72 khd ...... in SI units
to take place is termed as a draught.
C = 91.5 khd ...... in MKS units
STEAM POWER PLANT 207
24. Critical pressure ratio, 29. Optimum value of ratio of blade speed to steam speed is,
n cos
p2 FG 2 IJ n 1 opt. =
4
.
p1
=
H n 1K In general optimum blade speed ratio for maximum
...... condition for maximum discharge. blade efficiency or maximum work done is given by
25. The most important classification of steam turbines is as cos
opt. =
follows : 2n
(i) Impulse turbines (ii) Reaction turbines 1
(iii) Combination of impulse and reaction turbines. and the work done in the last row = of total work,
2n
26. s (Cw Cw ) Nm
Force (tangential) on the wheel = m where n is the number of moving rotating blade rows in
1 0
series.
LM m s (Cw Cw0 ) ... in MKS units.
OP 30. The degree of reaction of reaction turbine stage is defined
N g 1
Q as the ratio of heat drop over moving blades to the total
heat drop in the stage.
s (Cw Cw ) Cbl
m 31. The blade efficiency of the reaction turbine is given by
1 0
Power per wheel = kW 2
1000 bl = 2 – ;
LMH.P. per wheel = 2 (Cw Cw ) Cbl
m 1 0
... is MKS units.
OP 1 2 cos 2
bl becomes maximum when, = cos
MN g 75 PQ 2 cos2
2Cbl (Cw1 Cw0 ) and hence, (bl)max = .
Blade or diagram efficiency, bl = 1 cos2
C12 32. The principal methods of steam governing are as follows :
(i) Throttle governing
Cbl (Cw1 Cw0 )
Stage efficiency, stage = (ii) Nozzle governing
(h1 h2 ) (iii) By-pass governing
LM Cbl (Cw Cw )
1 0
... in MKS units.
OP (iv) Combination of (i), (ii) and (iii).
MN gJ (h1 h2 ) PQ 33. Condenser efficiency is defined as the ratio of the
difference between the outlet and inlet temperatures of
27. The axial thrust on the wheel due to difference between
cooling water to the difference between the temperature
the velocities of flow at entrance and outlet.
corresponding to the vacuum in the condenser and inlet
s (Cf Cf ).
Axial force on the wheel = m temperature of cooling water.
1 0
N g 1 0
Q ......Surface condenser.
THEORETICAL QUESTIONS
1. How are steam power plants classified ? 9. Enumerate and explain the steps involved in handling of
2. Give the layout of a modern steam power plant and explain the coal.
it briefly. 10. Explain with the help of a neat diagram the arrangement
3. What are the essential requirements of steam power of the Fluidised bed combustion (FBC) system.
station design ? 11. State the characteristics of a good ash handling plant.
4. What factors should be taken into consideration while 12. Enumerate and explain various modern ash-handling
selecting the site for steam power plant ? systems.
5. How can the capacity of a steam power plant be 13. How are dust collectors classified ?
determined ? 14. Explain with the help of a diagram the working of a
6. On factors does the choice of steam conditions depend ? ‘cyclone separator’.
7. Enumerate the means by which the coal from coal mines 15. How do you define the ‘collection efficiency’ of a dust
can be transported. separator ?
8. What are the requirements of good coal handling plant ? 16. What are the uses of ash and dust ?
208 POWER PLANT ENGINEERING
17. Give the general layout of ash handling and dust collection (ii) Factor of evaporation
system. (iii) Boiler efficiency.
18. What is the function of a boiler chimney ? 35. Define the term ‘steam nozzle’. Explain various types of
19. Why is there no chimney in the case of a locomotive boiler ? nozzles.
20. What do you understand by the term “Boiler draught” ? 36. What is the effect of friction on the flow through a steam
21. What are the limitations of chimney draft ? nozzle? Explain with the help of a h-s diagram.
22. Define the chimney efficiency and find out expression for 37. What do you mean by a super-saturated flow ? Explain
the same. with the help of h-s diagram.
38. Define the following in relation to steam turbines :
23. What are the various types of draughts used in usual
practice ? (i) Speed ratio
24. What are the advantages of artificial draught over natural (ii) Blade velocity coefficient
draught ? (iii) Diagram efficiency
25. What do you understand by steam jet draught ? Where is (iv) Stage efficiency.
it general employed ? 39. Discuss various methods of compounding steam turbines.
26. How are boilers classified ? 40. Describe briefly the various methods of ‘steam turbine
governing’.
27. Explain the unique features of the high pressure boilers.
41. Define a steam condenser and state its functions.
28. Explain with neat sketches the construction and working
42. Explain the reasons for inefficiency in surface condensers.
of any two of the following high pressure boilers ?
43. Explain the effects of air leakage in a condenser.
(i) LaMont boiler (ii) Loeffler boiler
44. What is a cooling tower ? How are cooling towers
(iii) Benson boiler (iv) Velox boiler.
classified ? Explain any one of them with a neat sketch.
29. Write short notes on the following : 45. How are impurities in water classified ?
(i) Supercharged boilers (ii) Supercritical boilers. 46. Enumerate various methods of feed water treatment.
30. Why are the accessories used in a boiler ? 47. Explain briefly any two of the following methods of feed
31. Explain briefly any two of the following boiler accessories : water treatment :
(i) Economiser (i) Sodium zeolite process
(ii) Air preheater (ii) Deaeration
(iii) Superheater. (iii) Coagulation.
32. How are feed water heaters classified ? 48. What are the requirements of steam piping system ?
33. What is an evaporator ? How are evaporators they 49. List the advantages and disadvantages of steam power
classified ? plants.
34. Define the following : 50. Give comparison between steam, hydroelectric, diesel and
(i) Equivalent evaporation nuclear power plants.
UNSOLVED EXAMPLES
CHIMNEY DRAUGHT
1. Calculate the quantity of air supplied per kg of fuel burnt 4. A forced draught fan discharges 1,200 m3 of air per minute
in the combustion chamber of a boiler when the required through the outlet of 2.1 m2 and maintains a static
draught of 1.85 cm of water is produced by a chimney of pressure of 10 cm of water. The temperature of air is 27°C.
32 m height. The temperatures of the flue gases and Calculate the BHP of the motor to drive the forced draught
ambient air recorded are 370°C and 30°C respectively. fan if the efficiency of the fan is 80%. Assume that the
[Ans. 15.3 kg] weight of 1 m3 of air at N.T.P. is 1.293 kg. [Ans. 35.15]
2. Determine the draught produced in cm of water by a 5. Calculate the quantity of air required per kg of coal burnt
chimney of 50 metres height when the temperature of the in a boiler fitted with 32 m high stack. Draught produced
flue gases passing through the chimney is such that the is 18.5 mm of water when the temperature of flue gases
mass of flue gases discharge is maximum in a given time. in the chimney is 370°C and that of boiler house is 30°C.
The ambient air temperature is 20°C. [Ans. 30.2 mm] Calculate also the draught produced in terms of height of
3. A boiler is provided with a chimney of 24 m height. The a column of hot gas in metres. [Ans. 15.3 kg, 31.65 m]
ambient temperature is 25°C. The temperature of flue 6. Forced draught fan delivers air at 10 m/s against a draught
gases passing through the chimney is 300°C. If the air of 25 mm of water across the fuel bed on the grate.
flow through the combustion chamber is 20 kg/kg of Determine the H.P. required to drive the fan if 10000 kg
fuel burnt, find (i) the theoretical draught in cm of water, of coal is burnt per hour with 13 kg of air required per kg
(ii) velocity of the flue gases passing through the chimney of coal burnt. Barometer reading is 1 kgf/cm2. Boiler house
if 50% of the theoretical draught is lost in friction at grate temperature is 20°C. Assume the efficiency of the fan to
and passage. [Ans. 12.9 mm of water, 14 m/s] be 81.5 per cent. [Ans. 16]
STEAM POWER PLANT 209
7. With a chimney of height 40 metres, the temperature of 13. A boiler with superheater generates 6000 kg/hour of steam
flue gases with natural draught was 350°C. The same at 15 bar and 0.8 dryness. The boiler exit temperature is
draught was developed by induced draught fan and the 300°C. The feed water temperature is 80°C. The overall
temperature of the flue gases was 150°C. Mass of the flue efficiency of the plant is 85%. Determine the consumption
gases formed is 20 kg per kg of coal fired. The boiler house rate, assuming a calorific value of 30,000 kJ/kg. Also find
temperature is 38°C. Determine the efficiency of the the equivalent evaporation from and at 100°C. What will
chimney. Assume cp = 0.24 kcal/kg K for the flue gases. be the area of superheater surface if the overall heat
[Ans. 1.177%] transfer coefficient is 450,000 kJ/m2-h ?
8. In a steam power plant, the height of the chimney installed [Ans. 646 kg/h, 7200 kg/h, 3.86 m2]
is 30 metres. When the plant was working with natural 14. A boiler generates 500 kg/hour of steam at 18 bar the steam
draught, the temperature of the gases was observed to be temperature being 325°C. The feed water temperature is
327°C. Induced fan was installed and same draught was 49.4°C. The efficiency of the boiler is 80%. When using oil
produced with the temperature of gases falling to 227°C. of calorific value 44,500 kJ/kg, the steam generated is
The gases formed per kg of coal amount to 20 kg. The supplied to a turbine developing 500 kW, and exhausting
atmospheric air temperature of surrounding is 27°C. at 1.8 bar, the dryness of exhaust steam 0.98. Calculate
the oil burnt per hour and turbine efficiency. Also find
Determine the efficiency of the chimney. Assume cp = 0.25
the energy available in the exhaust steam above 49.4°C.
kcal/kg °C for gases. [Ans. = 0.254%]
[Ans. 2448.8 kJ/kg]
9. A steam plant developing 1500 H.P. has a 55 m high
15. 5400 kg of steam is produced per hour at a pressure of
chimney. The coal consumption is 2.27 kg/H.P. hr and air
supplied is 19 kg/kg of fuel burnt. Assume an air 7.5 bar in a boiler with feed water at 41.5°C. The dryness
temperatures of 30°C and the discharge through the fraction of steam at exit is 0.98. The amount of coal burnt
chimney is maximum, find the diameter of the chimney. per hour is 670 kg of calorific value 31000 kJ/kg.
[Ans. 1.12 m] Determine :
10. A boiler is to use 1500 kg of coal per hour with the (i) The boiler efficiency (ii) Equivalent evaporation.
formation of 16 kg of flue gases per kg of fuel burnt. The [Ans. (i) 66.2%, (ii) 9.12 kg/kg of coal]
draught losses are given below : 16. A boiler with superheater generates 600 kg/hour of steam
Loss through the grate = 4.5 mm of water ; loss through at 15 bar and 0.98 dryness. The boiler exit temperature is
the flues = 7.8 mm of water ; loss through bends etc. 300°C. The feed water temperature is 80°C. The overall
= 3.4 mm of water ; head equivalent to velocity of gas flow efficiency of the plant is 85%.
= 0.5 mm of water. (i) Determine the coal consumption rate if calorific value
The average temperature of the outside air is 27°C and of coal is 30,000 kJ/kg.
the chimney gases have a mean temperature of 25°C. The (ii) Find the equivalent evaporation from and at 100°C.
actual draught produced may be assumed to be 80% of (iii) What will be the area of superheater surface if the
the theoretical draught, and the velocity of flow coefficient overall heat transfer coefficient is 450000
may be assumed to be 0.35, find the height and diameter kJ/m2-h ?
of the chimney. [Ans. H = 44.25 m, D = 2.8 m] [Ans. (i) 646 kg/h, (ii) 7200 kg/h-m, (iii)3.86 m2]
11. In a boiler plant a draught of 33.25 m column of hot gases
17. During a boiler trial the following observations were
is produced with the help of a chimney of 42.5 m height.
made :
The mass of flue gases formed per kg of flue burnt is 20 kg.
Duration of trial = 1 hour ; steam generated = 35500 kg ;
Assuming an ambident air temperature of 33°C, find the
following : steam pressure = 12 bar ; steam temperature = 250°C ;
temperature of water entering economiser = 17°C,
(i) Temperature of flue gases leaving the chimney.
temperature of water leaving economiser = 77°C ; oil burnt
(ii) Extra heat carried away by flue gases if the same
= 3460 kg ; calorific value of oil = 39500 kJ/kg.
draught can be produced by forced draught fan
reducing the gas temperature to 120°C which is the Calculate :
limit imposed due to condensation of water vapour. (i) Equivalent evaporation per kg of fuel
Take cp (for flue gases) = 0.25 kcal/kg °C. (ii) Thermal efficiency of plant
(iii) Efficiency of the chimney. (iii) Percentage of heat energy of the fuel energy utilised
(iv) Percentage of heat of fuel used for creating the by the economiser.
draught.
[Ans. (i) 13.02 kg, (ii) 74.4%, (iii) 6.52%]
(v) Temperature of chimney gases and corresponding
draught for the condition of maximum discharge 18. In a boiler trial of one hour duration the following
through the chimney. Take calorific vaue of fuel observations were made :
= 7500 kcal/kg. Steam generated = 5250 kg ; coal burnt = 695 kg ; calorific
[Ans. (i) 302°C, (ii) 45.5 kcal/kg of gas, (iii) 0.1712%, value of coal = 30200 kJ/kg ; dryness fraction of steam =
(iv) 12.13%, (v) 372°C and 24.5 mm of water column] 0.94 ; rated pressure of the boiler = 12 bar ; temperature
of steam leaving the superheater = 240°C ; temperature
PERFORMANCE OF BOILERS of hot well = 47°C.
Calculate :
12. 8 kg of steam is produced at 14 bar and 0.95 dryness in a
boiler fed with water at 39°C, per kg of coal consumed. (i) Equivalent evaporation per kg of fuel without
Determine the equivalent evaporation from and at 100°C. superheater.
[Ans. 8.96 kg/kg of coal] (ii) Equivalent evaporation per kg of coal with
superheater.
210 POWER PLANT ENGINEERING
(iii) Thermal efficiency of the boiler without superheater. is 10% of the total heat drop, calculate the mass of steam
(iv) Thermal efficiency of boiler with superheater. discharged when exit diameter of the nozzle is 12 mm.
(v) Heat supplied by the superheater per hour. [Ans. 224.3 kg/h]
Take cp of steam 2.184. 25. The inlet conditions of steam to a convergent-divergent
[Ans. (i) 8.26 kg/kg of fuel, (ii) 9.04 kg/kg of fuel, nozzle is 22 bar and 260°C. The exit pressure is 4 bar.
(iii) 61.7%, (iv) 67.53%, (v) 1.22 × 105 kJ/h] Assuming frictionless flow upto the throat and a nozzle
efficiency of 85%, determine :
19. A boiler is provided with an economiser and a superheater.
The steam is generated at 21 bar and 0.97 dry. This steam (i) The flow rate for a throat area of 32.2 cm2.
is passed onto a superheater and it leaves the superheater (ii) The exit area. [Ans. (i) 11 kg/s ; (ii) 60.5 cm2]
at 250°C. Feed water is supplied to the economiser at 38°C 26. In a steam nozzle, dry and saturated steam is expanded
and leaves the economiser at 77°C. The quantity of feed from 10 bar to 0.1 bar. Using steam tables, calculate :
water supplied is 10 kg/kg of fuel which has a calorific (i) Dryness fraction of steam at exit
value of 32600 kJ/kg. Determine : (ii) Heat drop
(i) Efficiency of the entire boiler plant. (iii) The velocity of steam at exit from the nozzle when
(ii) Percentage of heat received in the economiser. initial velocity is 135 m/s.
(iii) Percentage of heat received in the superheater. [Ans. (i) 0.79 ; (ii) 694 kJ/kg ; (iii) 1185.8 m/s]
[Ans. (i) 88.9%, (ii) 5.6%, (iii) 3.4%] 27. Determine throat area, exit area and exit velocity for a
20. The following observations were made during a boiler steam nozzle to pass 0.2 kg/s when the inlet conditions
trial : are 12 bar and 250°C and the final pressure is 2 bar.
Weight of feed water = 1520 kg/h ; temperature of feed Assume that the expansion is isentropic and that the inlet
water = 30°C ; steam pressure = 8.5 bar ; steam velocity is negligible. Take n = 1.3 for superheated steam.
temperature = 172.9°C ; dryness fraction of steam = 0.95 ; [Ans. 1.674 cm2; 2.015 cm2; 831.6 m/s]
coal burnt = 200 kg/hour ; calorific value of coal = 27200 28. The inlet conditions to a steam nozzle are 10 bar and
kJ/kg ; ash and unburnt coal collected = 16 kg/hour ; 250°C. The exit pressure is 2 bar. Assuming isentropic
calorific value of ash and unburnt coal = 2720 kJ/kg ; expansion and negligible velocity, determine :
weight of flue gases = 17.3 kg/kg of coal, temperature of (i) The throat area. (ii) The exit velocity.
flue gases = 330°C ; boiler room temperature = 18°C ; cp (iii) The exit area of the nozzle.
for gases = 1.006 kJ/kg °C. [Ans. (i) 1.44 cm2 ; (ii) 795 m/s ; (iii) 2.15 cm2]
Calculate the boiler efficiency. [Ans. 70%] 29. Dry saturated steam is passed at 7 bar through a
21. Compare the thermal efficiency of two boilers for which convergent-divergent nozzle. The throat cross-sectional
the data are given below : area is 4.5 cm2. Find the mass of steam passing through
Boiler 1 Boiler 2 the nozzle per minute. [Ans. 27 kg/min.]
Steam pressure 14 bar 14 bar
Steam produced per kg 10 kg 14 kg IMPULSE TURBINES
of coal fired
30. A steam jet enters the row of blades with a velocity of
Quality of steam 0.9 dry uperheated 380 m/s at an angle of 22° with the direction of motion of
to 240°C the moving blades. If the blade speed is 180 m/s and there
Feed water temperature 27°C 27°C is no thrust on the blades, determine the inlet and outlet
Calorific value of fuel 3400 kJ/kg 46000 kJ/kg blade angles. Velocity of steam while passing over the
Specific heat of feed water is 4.18 kJ/kg K and specific blades is reduced by 10%. Also determine the power
heat of steam is 2.1 kJ/kg K. developed by turbine when the rate of flow of steam is
1000 kg per minute. [Ans. 879 kW]
Which boiler is more efficient = ?
[Ans. boiler 1 = 7.3%, boiler 2 = 79.5%] 31. In a simple impulse turbine, the nozzles are inclined at
20° to the direction of motion of moving blades. The steam
leaves the nozzles at 375 m/s. The blade speed is 165 m/s.
STEAM NOZZLES Find suitable inlet and outlet angles for the blades in order
that the axial thrust is zero. The relative velocity of steam
22. Dry saturated steam enters a steam nozzle at pressure of
as it flows over the blades is reduced by 15% by friction.
12 bar and is discharged to a pressure of 1.5 bar. If the
Determine also the power developed for a flow rate of
dryness fraction of a discharged steam is 0.95 what will
10 kg/s. [Ans. 34°, 41°, 532 kW]
be the final velocity of steam ? Neglect initial velocity of
steam. If 12% of the heat drop is lost in friction, find the 32. In an impulse turbine the nozzles are inclined at 24° to
percentage reduction in the final velocity. the plane of rotation of the blades. The steam speed is
1000 m/s and blade speed is 400 m/s. Assuming
[Ans. 633.3 m/s, 6.2%]
equiangular blades, determine :
23. In a steam nozzle, the steam expands from 3 bar to 1.0
(i) Blade angles
bar. The initial velocity is 90 m/s and initial temperature
is 150°C. The nozzle efficiency is 0.95. Determine the exit (ii) Force on the blades in the direction of motion
velocity. [Ans. 594 m/s] (iii) Axial thrust
24. Steam initially dry and saturated is expanded in a nozzle (iv) Power developed for a flow rate of 1000 kg/h.
from 12 bar to 0.95 bar. If the frictional loss in the nozzle [Ans. (i) 39°, (ii) 1.135 kN, (iii) 113.5 kW]
STEAM POWER PLANT 211
33. In a De Laval turbine, the steam issues from the nozzles blade speed ratio. The blade inlet angle is equal to the
with a velocity of 850 m/s. The nozzle angle is 20%. Mean outlet angle. Determine :
blade velocity is 350 m/s. The blades are equiangular. The (i) Blade angles
mass flow rate is 1000 kg/min. Friction factor is 0.8. (ii) Power developed if the steam flow rate is 0.472 kg/s.
Determine : (i) blade angles, (ii) axial thrust on the end [Ans. (i) 36°, (ii) 75 kW]
bearing, (iii) power developed in kW, (iv) blade efficiency, 40. Steam at 7 bar and 300°C expands to 3 bar in an impulse
(v) stage efficiency, if nozzle efficiency is 93%. stage. The nozzle angle is 20°, the rotor blades have equal
[Ans. (i) 33°, 33°, (ii) 500 N, (iii) 4666.7 kW, inlet and outlet angles and the stage operates with the
(iv) 77.5%, (v) 72.1%] optimum blade speed ratio. Assuming that isentropic
34. In a single stage impulse turbine the nozzles discharge efficiency of nozzles is 90% and velocity at entry to the
the steam on to the blades at an angle of 25° to the plane stage is negligible, deduce the blade angles used and the
of rotation and the fluid leaves the blades with an absolute mass flow required for this stage to produce 50 kW.
velocity of 300 m/s at an angle of 120° to the direction of [Ans. 36°, 0.317 kg/s]
motion of the blades. If the blades have equal inlet and 41. In a two stage velocity compounded steam turbine, the
outlet angles and there is no axial thrust, estimate : mean blade speed is 150 m/s while the steam velocity as
(i) Blade angle it is issued from the nozzle is 675 m/s. The nozzle angle is
(ii) Power produced per kg/s flow of steam 20°. The exit angle of first row moving blade, fixed blade
(iii) Diagram efficiency. [Ans. (i) 36.3°, (ii) 144 kW, and the second row moving blades are 25°, 25° and 30°
(iii) 0.762] respectively. The blade friction coefficient is 0.9. If the
35. Steam enters the blade row of an impulse turbine with a steam flow rate is 4.5 kg/s, determine :
velocity of 600 m/s at an angle of 25° to the plane of rotation (i) Power output (ii) Diagram efficiency.
of the blades. The mean blade speed is 255 m/s. The blade [Ans. (i) 807 kW; (ii) 78.5%]
angle on the exit side is 30°. The blade friction coefficient
is 10%. Determine : REACTION TURBINES
(i) Work done per kg of steam
(ii) Diagram efficiency 42. At a particular stage of reaction turbine, the mean blade
(iii) Axial thrust per kg of steam/s. speed is 60 m/s and the steam pressure is 3.5 bar with a
[Ans. (i) 150.45 kW, (ii) 83.6%, (iii) 90 N] temperature of 175°C. The identical fixed and moving
36. The nozzles of an impulse turbine are inclined at 22° to blades have inlet angles of 30° and outlet angles of 20°.
the plane of rotation. The blade angles both at inlet and Determine :
outlet are 36°. The mean diameter of the blade ring is 1
(i) The blade height if it is th of the blade ring
1.25 m and the steam velocity is 680 m/s. Assuming 10
shockless entry determine : diameter, for flow rate of 13.5 kg/s.
(i) the speed of the turbine rotor in r.p.m., (ii) The power developed by a pair.
(ii) the absolute velocity of steam leaving the blades, and (iii) Specific enthalpy drop if the stage efficiency is 85%.
(iii) the torque on the rotor for a flow rate of 2500 kg/h. [Ans. (i) 64 mm, (ii) 218 kW, (iii) 19.1 kJ/kg]
[Ans. (i) 4580 r.p.m., (ii) 225 m/s, (iii) 290.5 Nm] 43. In a stage of impulse reaction turbine operating with 50%
37. A single stage steam turbine is provided with nozzles from degree of reaction, the blades are identical in shape. The
which steam is released at a velocity of 1000 m/s at an outlet angle of the moving blades is 19° and the absolute
angle of 24° to the direction of motion of blades. The speed discharge velocity of steam is 100 m/s in the direction at
of the blades is 400 m/s. The blade angles at inlet and 100° to the motion of the blades. If the rate of flow of steam
outlet are equal. Find : through the turbine is 15000 kg/h, calculate the power
(i) Inlet blade angle, developed by the turbine in kW. [Ans. 327.5 kW]
(ii) Force exerted on the blades in the direction of their 44. At a stage in a reaction turbine the pressure of steam
motion, is 0.34 bar and the dryness 0.95. For a flow rate of
(iii) Power developed in kW for steam flow rate of 40,000 36000 kg/h, the stage develops 950 kW. The turbine runs
kg/h. Assuming that the steam enters and leaves the at 3600 r.p.m. and the velocity of flow is 0.72 times the
blades without shock. blade velocity. The outlet angle of both rotator and rotor
[Ans. (i) 30°, (ii) 1135 N, (iii) 4540 kW] blades is 20°. Determine at this stage :
38. In a single row impulse turbine the nozzle angle is 30° (i) Mean rotor diameter, (ii) Height of blades.
and the blade speed is 215 m/s. The steam speed is 550 m/s. [Ans. (i) 0.951 m, (ii) 115 mm]
The blade friction coefficient is 0.85. Assuming axial exit 45. In a multi-stage reaction turbine at one of the stages the
and a flow rate of 700 kg/h, determine : rotor diameter is 1250 mm and speed ratio 0.72. The speed
(i) Blade angles of the rotor is 3000 r.p.m. Determine :
(ii) Absolute velocity of steam at exit (i) The blade inlet angle if the outlet blade angle is 22°,
(iii) The power output of the turbine. (ii) Diagram efficiency,
[Ans. (i) 46°, 49° ; (ii) 243 m/s ; (iii) 19.8 kW] (iii) The percentage increase in diagram efficiency and
39. In a steam turbine, steam expands from an inlet condition rotor speed if turbine is designed to run at the best
of 7 bar and 300°C with an isentropic efficiency of 0.9. theoretical speed.
The nozzle angle is 20°. The stage operates at optimum [Ans. (i) 61.5°, (ii) 82.2%, (iii) 30.47%]
212 POWER PLANT ENGINEERING
46. In a 50 per cent reaction turbine stage running at 3000 = 18°C, Circulating cooling water outlet temperature
r.p.m., the exit angles are 30° and the inlet angles are = 30°C ; Quantity of cooling water = 1300 kg/min.
50°. The mean diameter is 1 m. The steam flow rate is Determine :
10000 kg/min and the stage efficiency is 85%. Determine : (i) Vacuum efficiency,
(i) Power output of the stage. (ii) Undercooling of condensate,
(ii) The specific enthalpy drop in the stage. (iii) Condenser efficiency,
(iii) The percentage increase in relative velocity of steam (iv) Condition of steam as it enters the condenser,
when it flows over the moving blades.
(v) Mass of air per kg of uncondensed steam.
[Ans. (i) 11.6 MW, (ii) 82 kJ/kg, (iii) 52.2%]
Take : R for air = 0.287 kJ/kg K.
47. Twelve successive stages of a reaction turbine have blades
with effective inlet and outlet angles of 80° and 20° Specific heat of water = 4.186 kJ/kg K.
respectively. The mean diameter of the blade row is 1.2 m [Ans. (i) 94.47%, (ii) 6°C, (iii) 37.5%,
and the speed of rotation is 3000 r.p.m. Assuming constant (iv) 0.898, (v) 1.613 kg]
velocity of flow throughout, estimate the enthalpy drop 50. A surface condenser is fitted with separate air and
per stage. condensate outlets. A portion of the cooling surface is
For a steam inlet condition of 10 bar and 250°C and on screened from the incoming steam and the air passes over
outlet condition of 0.2 bar, estimate the stage efficiency. these screened tubes to the air extraction and becomes
Assume a reheat factor of 1.04, determine the blade height cooled below the condesate temperature. The condenser
at a stage where the specific volume is 1.02 m3/kg. receives 20000 kg/h of steam dry saturated at 36.2°C. At
condensate outlet, the temperature is 34.6°C, and at the
[Ans. 40.4 kJ/kg, 70.3%, 57 mm]
air extraction the temperature is 29°C. The volume of air
plus vapour leaving the condenser is 3.8 m3/min. Assuming
STEAM CONDENSERS constant pressure throughout the condenser, calculate :
(i) The mass of air removed per 10000 kg of steam.
48. A prime mover uses 16,000 kg of steam per hour and
develops 2600 kW. The steam is supplied at 30 bar and (ii) The mass of steam condensed in the air cooler per
300°C. The exhaust from the prime mover is condensed minute.
at 725 mm Hg (0.984895 bar) when barometer records (iii) The heat to be removed per minute by the cooling
755 mm Hg (1.006584 bar). The condensate temperature water.
from the condenser is 30°C and the rise of temperature of Neglect the partial pressure of the air inlet to the
circulating water is from 7°C to 17°C. Determine : condenser.
(i) The quality of steam entering the condenser. [Ans. (i) 2.63 kg, (ii) 0.492 kg, (iii) 807050 kJ]
(ii) The quantity of circulating cooling water and the ratio 51. Separate air pump and water pump are installed in a
of cooling water. condenser. Steam enters the condenser at 40°C and
Assume all mechanical drive losses are negligible and no condensate is removed at 37°C. The quantity of air
air is present in the condenser. infilrating into the condenser through various zones is
[Ans. (i) 0.9496, (ii) 873028 kg/h, 54.56 kg/kg] 5 kg/hour.
49. The observations recorded during the trial on a steam (i) What will be the volume of air handled by the air
condenser are given below : pump?
Condenser vacuum = 685 mm Hg ; Barometer reading (ii) What will be the quantity of handled by a combined
= 765 mm Hg ; Mean condensate temperature = 34°C ; air and condensate pump at 38°C?
Hot well temperature = 28°C ; Condensate formed per hour Make suitable assumptions and list all such
= 1750 kg ; Circulating cooling water inlet temperature assumptions. [Ans. (i) 400.8 m3/h ; (ii) 776 m3/h]
Temperature of feed water = 36.5°C 12. (a) What are characteristics of turbo-alternators ?
Coal consumption = 680 kg/hour (b) During a trial of 20 minutes the following observations
Calorific value of coal = 7450 kcal/kg were made on a single cyclinder double-acting steam
If by fitting an economiser, the temperature of feed water engine when running on light load—barometer 76 cm
is raised to 100°C, what will be saving in coal consumption of Hg ; total steam used 51 kg ; gauge pressure of steam
per hour if the other data remains unchanged and there in valve chest 2 kgf/cm2 ; the engine rejected exhaust
is 5% increase in the efficiency of the boiler ? steam into a condenser at the pressure of atmosphere
4. (a) What are the different methods of burning solid coal which is 1.03 kgf/cm2. The state of the steam in the
on a grate ? valve chest was found to be dry and saturated. Mean
engine speed 120 r.p.m. ; mean effective pressure :
(b) Explain the over-feed system of combustion.
outstroke 1.06 kgf/cm2, instroke 0.984 kgf/cm2 ; piston
(c) Explain with the help of neat diagram spreader stoker rod diameter 21.5 cm ; stroke 30.8 cm ; piston rod
and also explain its advantages over other type of diameter 3.7 cm. Net brake load (W-S) 50.5 kg. Brake
stoker. wheel radius = 1.2 m condensate at the rate of
5. (a) Sketch and describe the elements of a hydraulic ash 2.850 kg/hr with a rise in temperature of 24°C.
handling system for slag tap furnace. Temperature of the condensate leaving the condenser
(b) (i) What is the purpose of feed water heating in a 60°C.
steam power plant ? Calculate :
(ii) What are the different types of feed water heaters ? (i) The steam consumption in kg/1 HP-hr ;
(iii) Explain with the help of a diagram the direct (ii) The mechanical efficiency ;
contact feed water heating.
(iii) The brake thermal efficiency of the engine.
6. (a) Explain with the help of neat sketches the working of
Draw up a heat balance sheet for the plant on minute
‘forced draft’ and ‘induced draft’ cooling towers.
basis taking condensate temperature as datum.
(b) What is the importance of high purity water in high
13. (a) Describe methods of loading steam stations,
pressure boilers ? Explain the method used for water
hydrostations and nuclear stations.
purifying when the make up water is required for high
pressure boilers. (b) State the criteria for optimum loading of power plant.
7. Write notes on any two of the following : 14. (a) Describe with a neat sketch the working of a travelling
grate stoker of a steam boiler.
(a) Scope of tidal power in India ;
(b) Describe pneumatic ash handling system in a modern
(b) Super-thermal power stations in India ;
steam generator.
(c) Selection of site for a hydro-power station.
15. (a) Draw p-v and T-s diagrams for the most commonly
8. (a) Why is superheating of steam essential in steam
used thermodynamic cycle for a thermal station.
power ?
(b) Steam at pressure 40 kgf/cm2 and 400°C temperature
(b) A small steam turbine develops 100 H.P. and used
is supplied to a steam turbine and is exhausted at
7 kg of steam per horse power hour. The steam is
pressure of 0.07 kgf/cm2. A single bleed is taken
supplied to the turbine pressure of 15 kg/cm2 at 240°C
between the H.P. cylinder and L.P. cylinder of the
and the steam is exhausted to condenser at a pressure
turbine at 2.5 kgf/cm2 for regenerative feed heating.
of 0.1 kg/cm2. The condensate leaves at 34°C. Calculate
The isentropic efficiency for both the cylinders of the
the dryness fraction of the exhaust steam entering
turbine is 85%. The temperature of the bleed
the condenser. Cooling water is supplied at 10°C and
condensate coming out of heat exchanger is 10°C lower
leaves at 22°C. Calculate the amount of cooling water
than the temperature of the bleed steam. Find out :
supplied per hour.
(i) Amount of bleed steam/kg of steam supplied to
Specific heat of superheated steam is 0.6. the turbine ;
9. (a) What are the ash handling systems ? (ii) The thermal efficiency of the plant.
Draw a line diagram of hydraulic ash handling system (Consider no losses and pump work as negligible. Let
for modern high capacity plants. Explain its working. the condensate coming out from the heat exchanger
(b) Draw a neat line diagram of inplant coal handling and condenser be led to the hot well).
system and explain the equipment used at different 16. Write detailed notes on the following :
stages. (a) Switch gears for power stations ;
10. (a) Describe with the help of neat diagram the working (b) Combined loading of thermal and hydroplants ;
of a plate type air heater used in a modern power plant. (c) Power from tides.
(b) What are the requirements of the burners used for 17. (a) What are the advantages of high pressure boilers ?
firing pulverised coal ? Describe with line sketches Discuss the guide lines for the selection of boilers for
the various types of burners used and their relative steam power plants.
merits and demerits.
(b) A steam power plant working on regenerative cycle
11. (a) Describe the working of a contact type feed water utilises steam at 42 kgf/cm2 and 400°C and the
heater with the help of neat diagram. condenser pressure is 0.963 kgf/cm2 vacuum. After
(b) Draw an outline of ash disposal equipment. State the expansion in the turbine to 5 kgf/cm2, a part of steam
advantages of hydraulic system of handling ash. What is extracted from the turbine for heating feed water
are the problems of has disposal ? from condenser in the open heater. Draw the cycle on
T-s diagram and find the thermal efficiency of the
214 POWER PLANT ENGINEERING
plant. Assume the heat drop to be isentropic and the 24. (a) Explain how the load distribution between two
atmospheric pressure may be taken equal to alternators of a generating station can be divided for
1.033 kgf/cm2. best economy.
18. (a) Make a list of the advantages of pulverised coal firing (b) The input-output curve of a 10 MW thermal station is
in a steam power plant. given by :
(b) Discuss in brief the ash handling systems in P.F. I = (10 + 8L + 0.4L2) 106 kcal/h
boilers. What are the difficulties in the handling of where L is in MW. Find out the load at which the plant
ash in a thermal power station ? runs at maximum efficiency and also the value of the
19. (a) Discuss how coil is handled in a medium capacity maximum efficiency.
thermal power plant. 25. (a) Draw an explanatory line diagram of an ash handling
(b) Make a list of advantages and disadvantages of stoker system used for a modern high capacity steam power
firing and explain the working of chain grate stoker plant. State its merits.
with simple sketch. (b) Describe, giving a neat diagram the working of a
20. A steam turbine using regenerative feed heat cycle cyclone burner. Why are such burners preferred for
generates 27000 kW through a directly coupled electric Indian coals ?
generator. Steam at 60 kgf/cm2 and 450°C is supplied to (c) Prove that for the same plant the power required by
the turbine. The condenser pressure is 730 mm an inducted draught fan will be more than that
Hg vacuum. The steam is bled from steam turbine at required by a forced draught fan assuming that the
3 kgf/cm2. The heating of feed water is done in direct efficiencies of both the fans are the same.
contact heater. Find : 26. (a) List the advantages and disadvantages of a surface
(a) Steam bled/kg of steam supplied ; condenser.
(b) Steam generated/hour ; (b) Draw the flow diagram of a steam turbine plant using
(c) Overall efficiency of the plant. reheating and regeneration. Represent the various
thermodynamic processes on a T-s diagram.
Assume turbine of each portion of expansion as 86%,
boiler = 90% alternator = 95%, mechanical from (c) A steam turbine develops 2.5 MW when the steam is
turbine to generator 98% and 10% of generator output is supplied at 10 kgf/cm2 abs and 250°C. The pressure
used to run the pump. Neglect pump work in calculating in the condenser is 0.14 kgf/m2 abs. Assuming the
input to the boiler. expansion efficiency through the turbine stage as 80%,
determine :
21. (a) Explain the advantages of combined of power plants.
(i) Specific steam consumption of the plant ;
(b) Explain the effect of load factor of an electric power
(ii) Thermal efficiency of the plant.
station on the cost of energy generated.
27. (a) What are the advantages of burning coal in pulverised
(c) The steam consumption rates in kg/hr for two steam
form ? Name the different types of coal pulverizing
turbines is given by the following equations ;
mills and discuss the outstanding features of each.
F1 = 2,000 + 10 P1 – 1 × 10–4 P12
(b) Explain, with the help of neat sketch, the working of
F2 = 4,000 + 7 P2 – 5 × 10–5 P22
an electrostatic precipitator and give its outstanding
where P represents the load in kW. features over other collectors.
Determine the most economical loading when the total 28. (a) What are the sources of air leakage into a condenser ?
load taken by both units is 30 MW. Discuss the effect of air leakage on the performance
22. (a) Explain how combustion takes place in overfeed and of a condenser.
underfeed stokers. Discuss their relative performance. (b) A two-stage regenerative cycle used steam at
(b) Explain the working of an electrostatic precipitator 70 kgf/cm2, 400°C with 25 mm of Hg back pressure.
and list its outstanding features. Station auxiliary power is 15% of turbine output. The
23. (a) Show that the thermal efficiency of a regenerative overall electrical and mechanical efficiency of turbine
cycle is greater than simple Rankine cycle. generator is 80% and the boiler efficiency is 85%. The
(b) Steam at 50 kgf/cm2 and 400°C is supplied to a two turbine has an engine efficiency of 88%. Compute the
stage turbine. The steam is first expanded in high overall station heat rate in kcal/kWh.
pressure turbine to 5 kgf/cm2. The steam is reheated 29. The following data refers to a boiler trial of a steam power
at 5 kgf/cm2 to 250°C using 0.96 dry steam from the plant :
boiler at 50 kgf/cm2. The reheated steam is passed Coal consumption = 4,0000 kg/hr
through low pressure stage and then exhausted to a Calorific value of coal = 8,500 kcal/kg
condenser at 0.03 kgf/cm2. The isentropic efficiency of
Ultimate analysis of coal C = 80%, H1 = 5%,
high pressure and low pressure stage may be assumed
same as 80%. Assuming that the mechanical efficiency H2O = 7%, ash = 8%
is 99% and generator efficiency is 96%, find the weight Orsat analysis of the gases CO2 = 10%, O2 = 8%,
of steam generated by the boiler per kWh. Assume CO = 2%, N2 = 80%
that the heating steam in the reheater given up heat Temperature of the gases = 300°C
by condensing only and the pump work and other
Boiler room temperature = 20°C
losses are neglected.
Steam generated = 40,000 kg/hr
STEAM POWER PLANT 215
Pressure of steam at stop valve = 14 kg/cm2 dry (iii) Lubrication system in diesel electric plant ;
Specific heat of gases = 0.24 (iv) Open cycle gas turbine.
Specific heat of superheat steam = 0.50 37. (a) List out the major advantages of high pressure boilers
Feed water temperature = 50°C in modern thermal power plants.
Draw the heat balance sheet of boiler based on 1 kg of (b) Draw a neat diagram of a volex boiler and discuss its
coal. merits. Explain its working principle.
Calculate also the amount of air needed in kg/hour if 50% 38. (a) Explain the working principle of the following :
excess air is supplied. (i) Economisers ;
30. (a) What difficulties are experienced in ash handling ? (ii) Air preheaters ;
Describe with the help of a diagram the working of a (iii) Superheaters.
pneumatic ash handling system.
(b) The steam at 90 kgf/cm2 ab. and 480°C is supplied to a
(b) Explain clearly the difference between overfeed and steam turbine. The steam is reheated to its original
underfeed systems of coal firing. Which is preferred temperature passing the steam through reheater at
for high volatile coal and why ? 12 kgf/cm2 ab. The expansion after the reheating, takes
31. (a) Draw a neat schematic diagram and temperature place to condenser pressure of 0.07 kgf/cm2 ab. Find
entropy diagram of thermodynamic cycle used in the efficiency of reheat cycle and work output if the
steam power plants and explain it in brief. flow of steam is 1 kg/s. Neglect the pressure loss in
(b) A steam turbine power plant working on Rankine the system and assume the expansion through the
cycle receives steam at a pressure of 90 kgf/cm2-ab turbine as isentropic. Do not neglect the pump work.
and temperature of 500°C. Steam is expanded in the 39. (a) Explain with neat diagram the working principle of
first stage of turbine to a pressure of 12 kgf/cm2-ab. travelling grate stoker.
It is then reheated to its initial temperature and (b) Why ash should be discharged ? Give reasons. List
then expanded in the second stage to a pressure of the difficulties encountered in the ash handling plant
0.07 kgf/cm2-ab. layout. Mention the places of disposal of ash.
Find : 40. (a) Give the classification of coal in the increasing order
(i) The efficiency of the cycle assuming isentropic of their heat value. Discuss each of them.
expansion efficiency of turbine in each stage to be 90% ; (b) Discuss the following pulverised fuel handling
(ii) Steam flow rate required to develop 10 MW of power ; systems :
(iii) Dryness fraction of steam leaving the turbine. (i) Unit system ;
32. (a) What are the advantages of burning fuel in pulverised (ii) Central or Bin system. Mention the advantages
form ? and disadvantages of them.
(b) Name the different types of coal pulverising mills and 41. (a) What is the function of cooling tower in a modern
discuss outstanding features of each. Name one which steam power plant ? Describe briefly with a neat sketch
is commonly used. the working of a hyperbolic cooling tower.
(c) What are the different methods used for supplying (b) The steam at 90 kgf/cm2-ab and 480°C is supplied to a
pulverised fuel to combustion chambers ? steam turbine. The steam is reheated to its original
33. (a) Draw a general layout of a thermal power plant and temperature passing the steam through reheater at
explain the working of difference circuits. 12 kgf/cm2-ab. The expansion after reheating takes
place to condenser pressure 0.07 kgf/cm2-ab. Find the
(b) What factors are considered in selecting a site for a efficiency of reheat cycle and work output if the flow
big thermal power plant? of steam is 1 kg/sec. Neglect the pressure loss in the
34. (a) Draw a line diagram of pneumatic ash handling system and assume the expansion through the turbine
system used for modern capacity power plant. Explain is isentropic. Do not neglect the pump work.
the difficulties encountered in its design and operation. 42. (a) What do you understand by the term “Draught” ?
When is this system preferred over other systems ?
How is the draughts classified ? Explain with neat
(b) Draw a neat line diagram of Benson boiler and explain sketch the balanced draught.
its working. Discuss its relative merits and demerits.
(b) What are the advantages of high pressure boiler ?
35. (a) Draw a neat diagram of multiretort under feed stoker Draw a neat line diagram of LaMont boiler and explain
and explain its working. Discuss its merits over other its working.
types of stokers.
43. (a) What do you understand by proximate and ultimate
(b) What are the advantages of burning the fuels in analysis of coal ? Discuss the role played by each
pulverised form ? constituent.
36. Write brief notes on the following : (b) Explain the coal preparation plant.
(i) Heat balance in steam power plant ; (c) Explain any three equipment used for the transfer of
(ii) Pumped storage hydroelectric power plant ; coal from unloading point to the storage site.
216 POWER PLANT ENGINEERING
44. (a) Describe the burning sequence of coal in ‘overfeed’ and (b) In a single stage regenerative cycle, steam is supplied
‘underfeed’ stokers. Which types of stoker is suitable to the steam turbine at 16 kgf/cm2 abs and 300°C and
to burn exhausts at 0.05 kgf/cm2 abs. The steam for feed
(i) High ash clinkering coals, heating is to be extracted at 1.6 kgf/cm2 abs. The drain
from the closed heater, at saturation temperature of
(ii) High volatile matter coal and bled steam pressure, is returned to the system at a
(iii) Low ash content coals ? point downstream from the heater and the feed water
(b) Why ash and dust handling problem is more difficult is heated to saturation temperature of bled steam.
than coal handling problems ? Explain them. Determine the regenerative cycle efficiency and
compare it with Rankine cycle working between the
45. Write short notes on the following :
same terminal conditions. Neglect pump work.
(i) Electrostatic precipitator ; Represent the processes on enthalpy-entropy plane,
(ii) Mechanical draft cooling tower ; if used.
(iii) Excitor and circuit breaker in a power plant. 50. (a) What are the advantages of using high pressure boilers
46. (a) Discuss briefly, with a line sketch, the different types in modern thermal power stations ? Discuss briefly
of burners used in firing pulverized coal in steam high temperature effects on steam piping in modern
boilers. boilers.
(b) The following observations were taken during a test (b) Steam is supplied to a 10 MW turbo-alternator at
on a steam generator : 40 kgf/cm2 abs and 400°C. Auxiliaries consume 7 per
cent of the output. The condenser pressure is 0.05 kgf/
Quantity of coal burnt per hour 750 kg cm2 abs and the condensate is subcooled to 30°C. Take
Feed water supplied per hour 7,000 kg boiler efficiency as 85 per cent and the relative
Calorific value of coal fired 8,100 kcal/kg efficiency of turbine as 0.8 and the mechanical
efficiency of the alternator as 95 per cent. Determine :
Feed water temperature entering economizer 25°C
(i) The steam consumption per hour ;
Feed water temperature leaving economizer 80°C
(ii) The overall efficiency of the plant ;
Steam pressure 10 kgf/cm2
(iii) The quality of steam at exit from turbine.
Dryness fraction of steam leaving boiler drum 0.95
Sketch the relevant portion of Mollier diagram, if used
Temperature of steam leaving superheater 250°C
for the solution.
Determine the thermal efficiency of the plant and also
51. (a) What are meant by ‘primary air’ and ‘secondary air’
calculate the heat absorbed by feed water in various
with regard to combustion for stoker firing and
components as a percentage of the total heat absorbed.
pulverised fuel firing ?
47. (a) Name the different boiler accessories.
(b) Describe briefly with a flow sheet the pulverised coal
(b) With a neat line sketch explain the working principle preparation systems and the method of firing of
of Schimdt-Hartmann boiler. pulverised fuel. Discuss briefly the advantages and
(c) Why is it important to purify water in high pressure disadvantages of pulverised coal firing.
boiler ? How are dissolved oxygen and silica removed 52. Describe briefly the elements of a hydraulic ash handling
from feed water ? system for a boiler furnance in a power station.
48. (a) Why is condenser used in steam power plant ? Discuss 53. The following data were obtained during a trial of a coal
the working of different parts of surface condenser. fired steam boiler with natural draught :
(b) The steam at 100 kgf/cm2 and 500°C expands in the Feed water temperature = 75°C
turbine up to 8.5 kgf/cm2 with an isentropic
Feed water supplied per hour to boiler = 4500 kg
efficiency of 80%. The steam is then reheated to
original temperature and then it expands in the lower Steam pressure = 11 kg/cm2 abs
stage of the turbine up to the condenser pressure of Dryness fraction of steam generated in boiler = 0.95
0.05 kgf/cm2. The isentropic efficiency of the lower Coal fired per hour = 400 kg
stage of the turbine is 85%. Find the thermal efficiency
of the cycle assuming the pressure loss in the reheater Higher calorific value of coal = 9400 kcal/kg
of 0.5 kgf/cm2. Moisture in coal 4.25 per cent by mass
If the expansion of the steam is allowed to continue in Temperature of flue gases discharged = 270°C
the lower part of the turbine with an isentropic Boiler room temperature = 30°C
efficiency of 75% without reheating, then find the
Analysis of dry coal by mass was : C = 89%, H2 = 3%, Ash
thermal efficiency of the cycle. Neglect the pump work
= 4% and other volatile matter = 4%
in both case.
The analysis of flue gas by volume was : CO2 = 10.9%, CO
49. (a) How is the efficiency of a steam plant improved
= 1.1%, O2 = 7% and N2 = 81%.
through regenerative cycle ? Show the cycle on
temperature-enthropy diagram and deduce an Draw up the heat balance for the boiler per kg of coal
expansion for its ideal efficiency. fired, and also determine the thermal efficiency of the
STEAM POWER PLANT 217
boiler. Assume sp. heat of dry flue gases as 0.23 and sp. 56. (a) Explain how required vacuum is maintained in the
heat of superheated steam in products of combustion as condenser of a steam power plant.
0.48. Also assume partial pressure of water vapour in flue (b) What are the disadvantages of ‘pulverised fuel firing
gases as 0.027 kg/cm2 abs. system’ ? Discuss how these disadvantages are
54. (a) What are the different methods to control superheat eliminated in more advanced methods of fuel firing
temperature in steam generators ? system.
(c) What are the harmful effects caused by using impure
(b) What are the differences between a feed water heater water in boiler ? State the various methods of purifying
and an economiser ? feed water.
(c) Discuss briefly the working of an economiser used in 57. In a 60 MW steam turbine plant steam is supplied to the
modern steam generator. How soot is cleaned from HP unit at 70 kgf/cm2 and 450°C. Steam is expanded to
economiser tubes ? 25 kgf/cm2 in the HP unit and before entering the IP unit
steam is reheated at constant pressure to 420°C.
55. (a) What are the advantages of using reheat steam cycle ? Expansion continues upto 10 kgf/cm2 in the IP unit when
(b) How in actual practice reheating is done in steam a portion of steam held at 10 kgf/cm2 is taken to a closed
power ? feed-water heater with drains pumped ahead. The
remaining steam expands to the condenser pressure of
(c) In a reheat cycle, with two stages of reheating, steam 0.07 kgf/cm2 in the LP unit. The isentropic efficiency of
at 210 kgf/cm2 and 550°C, enters the turbine and the HP stages 80% while that of IP and LP stages is 83%
expands to 41 kgf/cm2 abs. At this point the whole each. Using the following data only, determine :
steam is passed to the first reheater. The steam re- (a) Quantity of steam bled per kg of flow at the turbine
enters the turbine at the same pressure and expands inlet ;
further to 10 kgf/cm2 abs pressure. After expansion (b) Thermal efficiency ; and
the whole steam is passed to the second reheater. The (c) Steam consumption in tonnes/hour.
steam after second stage of reheating further expands
Neglect all pump work assume that feed-water is heated
to condenser pressure of 0.126 kgf/cm2 abs. The exist to the bled steam temperature in the heater. Draw the
of steam from both the reheaters is at 550°C and there schematic diagram of the plant and the corresponding
is no pressure drop in the reheaters. For the ideal T-s diagram.
reheat cycle determine the thermal efficiency.
Diesel Engine Power Plant 4
4.1. Introduction. 4.2. Advantages and disadvantages of diesel power plants. 4.3. Applications of diesel power plant.
4.4. Site selection. 4.5. Heat engines. 4.6. Classification of I.C. engines. 4.7. Different parts of I.C. engines. 4.8. Terms
connected with I.C. engines. 4.9. Four stroke cycle diesel engines. 4.10. Two stroke cycle diesel engines.
4.11. Comparison of four stroke and two stroke cycle engines. 4.12. Comparison between a petrol engine and a
diesel engine. 4.13. Essential components of a diesel power plant—Engine—Air intake system—Exhaust system—Fuel
system—Cooling systems—Lubrication systems—Engine starting system—Governing system. 4.14. Combustion
phenomenon in C.I. engines. 4.15. Delay period in C.I. engines. 4.16. Diesel knock. 4.17. Cetane number. 4.18. Basic
designs of C.I. engine combustion chambers. 4.19. Supercharging. 4.20. Operation of a diesel power plant. 4.21.
Types of diesel engine used for diesel power plants. 4.22. Layout of a diesel engine power plant. 4.23. Performance
of I.C. engines—Worked Examples—Highlights—Theoretical Questions—Unsolved Examples—Competitive Examinations
Questions.
6. The diesel power plants are not economical where to move a piston in a cylinder. Other examples of external
fuel has to be imported. combustion engines are hot air engines, steam turbine and
7. The life of a diesel power plant is quite small (2 closed cycle gas turbine. These engines are generally used
to 5 years or less) as compared to that of a steam power for driving locomotives, ships, generation of electric power
plant (25 to 30 years). etc.
2. Internal combustion engines (I.C. engines).
4.3. APPLICATIONS OF DIESEL POWER In this case, combustion of the fuel with oxygen of the air
PLANT occurs within the cylinder of the engines. The internal
combustion engines group includes engines employing
The diesel power plants find wide application in the mixtures of combustible gases and air, known as gas
following fields :
engines, those using lighter liquid fuel or spirit known as
1. Peak load plant 2. Mobile plants petrol engines and those using heavier liquid fuels, known
3. Stand-by units 4. Emergency plant as oil compression ignition or diesel engines.
5. Nursery station 6. Starting stations
7. Central stations—where capacity required is small 4.6. CLASSIFICATION OF I.C. ENGINES
(5 to 10 MW)
8. Industrial concerns where power requirement is Internal combustion engines may be classified as given
small say of the order of 500 kW, diesel power plants below :
become more economical due to their higher overall 1. According to cycle of operation
efficiency. (i) Two stroke cycle engines
(ii) Four stroke cycle engines.
4.4. SITE SELEC TION 2. According to cycle of combustion
The following factors should be considered while selecting (i) Otto cycle engine (combustion at constant
the site for a diesel power plant : volume)
1. Foundation sub-soil condition. The conditions (ii) Diesel cycle engine (combustion at constant
of sub-soil should be such that a foundation at a reasonable pressure)
depth should be capable of providing a strong support to (iii) Dual-combustion or Semi-Diesel cycle engine
the engine. (combustion partly at constant volume and
2. Access to the site. The site should be so selected partly at constant pressure).
that it is accessible through rail and road. 3. According to arrangement of cylinder
3. Distance from the load centre. The location (i) Horizontal engine
of the plant should be near the load centre. This reduces (ii) Vertical engine
the cost of transmission lines and maintenance cost. The
(iii) V-type engine
power loss is also minimised.
(iv) Radial engine etc.
4. Availability of water. Sufficient quantity of
water should be available at the site selected. 4. According to their uses
5. Fuel transportation. The site selected should (i) Stationary engine
be near to the source of fuel supply so that transportation (ii) Portable engine
charges are low. (iii) Marine engine
(iv) Automobile engine
4.5. HEAT ENGINES (v) Aero engine etc.
Any type of engine or machine which derives heat energy 5. According to the fuel employed and the
from the combustion of fuel or any other sources and converts method of fuel supply to the engine cylinder
this energy into mechanical work is termed as a heat (i) Oil engine
engine. (ii) Petrol engine
Heat engines may be classified into two main classes (iii) Gas engine
as follows : (iv) Kerosene engine etc.
1. External Combustion Engines. (v) Carburettor, hot bulb, solid injection and air
2. Internal Combustion Engines. injection engine.
1. External combustion engine (E.C. engines). 6. According to the speed of the engine
In this case, combustion of fuel takes place outside the (i) Low speed engine
cylinder as in case of steam engines where the heat of (ii) Medium speed engine
combustion is employed to generate steam which is used (iii) High speed engine.
220 POWER PLANT ENGINEERING
Wrist pin
Connecting rod
Cylinder
e
Crankcase Bor
Crank pin
Crankshaft
Crank Fig. 4.2. Terms relating to I.C. engines.
Bore. The inside diameter of the cylinder is called
bore.
Stroke. As the piston reciprocates inside the engine
cylinder, it has got limiting upper and lower positions
Fig. 4.1. Air-cooled I.C. engine. beyond which it cannot move and reversal of motion takes
place at these limiting positions.
DIESEL ENGINE POWER PLANT 221
The linear distance along the cylinder axis between shown by the line 2-3. At the point 3 fuel supply is cut-off.
two limiting positions, is called stroke. The fuel is injected at the end of compression stroke but in
Top Dead Centre (T.D.C.). The top most position actual practice the ignition of the fuel starts before the
of the piston towards cover end side of the cylinder is called end of the compression stroke. The hot gases of the cylinder
top dead centre. In case of horizontal engines, this is expand adiabatically to point 4, thus doing work on the
known as “inner dead centre.” piston. The expansion is shown by 3-4 (Fig. 4.4).
Bottom Dead Centre (B.D.C.). The lowest position 4. Exhaust stroke. The piston moves from the
of the piston towards the crank end side of the cylinder is B.D.C. to T.D.C. and the exhaust gases escape to the
called bottom dead centre. In case of horizontal engines atmosphere through the exhaust valve. When the piston
it is called “outer dead centre.” reaches the T.D.C. the exhaust valve closes and the cycle
Clearance volume. The volume contained in the is completed. This stroke is represented by the line 1-5
cylinder above the top of the piston, when the piston is at (Fig. 4.4).
top dead centre, is called the clearance volume.
F.I. F.I. F.I. F.I. Exhaust
Swept volume. The volume swept through by the Air gases
piston in moving between top dead centre and bottom dead
I.V. E.V. I.V. E.V.
centre, is called swept volume or piston displacement.
Thus, when piston is at bottom dead centre, total volume
= swept volume + clearance volume.
E.C.
Compression ratio. It is the ratio of total cylinder
volume to clearance volume.
C.R.
Refer to Fig. 4.2. Compression ratio (r) is given by
Vs Vc C
r=
Vc
where Vs = Swept volume, and
Vc = Clearance volume. Suction Compression Working Exhaust
stroke stroke stroke stroke
The compression ratio varies from 5 : 1 to 9 : 1 in
petrol engines and from 14 : 1 to 22 : 1 in diesel engines. F.I. = Fuel injector I.V. = Inlet valve E.V. = Exhaust valve
E.C. = Engine cylinder C.R. = Connecting rod C = Crank
Piston speed. The average speed of the piston is
called piston speed. Fig. 4.3. Four stroke diesel cycle engine.
Piston speed = 2 LN
where, L = Length of the stroke, and
N = Speed of the engine in r.p.m. 2 3
passages the entering air can’t cope with the speed of the Injector
piston. The exhaust line 4-5 is slightly above the
atmospheric line. This is because of the restricted exhaust
passages which do not allow the exhaust gases to leave the L
engine cylinder quickly.
T.P.
3 E.P.
M
2
Pressure
Exhaust
4 Atmospheric
5 V
1 line
Suction
Volume
C.C.
Fig. 4.5. Actual p-V diagram of four stroke diesel cycle. (iii)
The loop of area 4-5-1 is called negative loop ; it gives
the pumping loss due to admission of air and removal of L = Cylinder ; M = Piston ;
exhaust gases. The area 1234 is the total or gross work E.P. = Exhaust port ;
obtained from the piston and net work can be obtained by T.P. = Transfer port ;
subtracting area 451 from area 1234. C.C. = Crank chamber ;
V = Valve
4.10. TWO STROKE CYCLE DIESEL Fig. 4.6. Two stroke cycle engine.
ENGINES
upward stroke of the piston M, the gases in L are
Fig. 4.6 shows two stroke diesel engine. The cylinder L compressed and at the same time fresh air enters the
is connected to the closed crank chamber C.C. During the crankchamber through the valve V. When the piston moves
downward, V closes and air in the crank chamber is
Injector Injector
compressed. Refer to Fig. 4.6 (i). The piston is moving
upwards and is compressing the air which has previously
L L been supplied to L and before it (piston) reaches the T.D.C.
Hump
(top dead centre) the fuel injector supplies fuel to the engine
M cylinder. Ignition of fuel takes place due to high
T.P. T.P.
temperature of air and gases are produced. These gases
E.P. M E.P.
expand and the piston then travels downward [Fig. 4.6 (ii)]
and near the end of this stroke the piston uncovers the
exhaust port (E.P.) and the burnt exhaust gases escape
through this port [Fig. 4.6 (iii)]. The transfer port (T.P.)
then is uncovered immediately, and the compressed air
from the crank chamber flows into the cylinder and is
deflected upwards by the hump provided on the head of
the piston. It may be noted that the incoming air helps the
V V removal of gases from the engine-cylinder. The piston then
again starts moving from B.D.C. to T.D.C. and the air gets
compressed when exhaust port (E.P.) and transfer port
C.C. C.C. (T.P.) are covered by the piston ; thus the cycle is repeated.
(i) (ii)
DIESEL ENGINE POWER PLANT 223
1. The cycle is completed in four strokes of the piston or in 1. The cycle is completed in two strokes of the piston or in one
two revolutions of the crankshaft. Thus one power stroke revolution of the crankshaft. Thus one power stroke is
is obtained in every two revolutions of the crankshaft. obtained in each revolution of the crankshaft.
2. Because of the above turning-movement is not so uniform 2. More uniform turning movement and hence lighter flywheel
and hence heavier flywheel is needed. is needed.
3. Again because of one power stroke for two revolutions, 3. Because of one power stroke for one revolution, power
power produced for same size of engine is small or for the produced for same size of engine in more (theoretically twice,
same power the engine is heavy and bulky. actually about 1.8 times) or for the same power the engine
is light and compact.
4. Because of one power stroke in two revolutions lesser 4. Because of one power stroke in one revolution greater cooling
cooling and lubrication requirements. Lesser rate of wear and lubrication requirement. Great rate of wear and tear.
and tear.
5. The four stroke engine contains valve and valve 5. Two stroke engines have no valves but only ports (some two
mechanism. stroke engines are fitted with conventional exhaust valves).
6. Because of the heavy weight and complication of valve 6. Because of light weight and simplicity due to absence of
mechanism, higher is the initial cost. valve mechanism, cheaper in initial cost.
7. Volumetric efficiency more due to more time of induction. 7. Volumetric efficiency less due to lesser time for induction.
8. Thermal efficiency higher, part load efficiency better than 8. Thermal efficiency lower, part load efficiency lesser than
two stroke cycle engine. four stroke cycle engine.
9. Used where efficiency is important ; in cars, buses, trucks, 9. In two stroke petrol engine some fuel is exhausted during
tractors, industrial engines, aeroplane, power generators scavenging.
etc. Used where (a) low cost, and (b) compactness and light
weight important. Two stroke (air cooled) petrol engines
used in very small sizes only, lawn movers, scooters, motor
cycles (lubricating oil mixed with petrol).
Two stroke diesel engines used in very large sizes, more
than 60 cm bore, for ship propulsion because of low weight
and compactness.
1. Air petrol mixture is sucked in the engine cylinder Only air is sucked during suction stroke.
during suction stroke.
2. Spark plug is used. Employs an injector.
3. Power is produced by spark ignition. Power is produced by compression ignition.
4. Thermal efficiency up to 25%. Thermal efficiency up to 40%.
5. Occupies less space. Occupies more space.
6. More running cost. Less running cost.
7. Light in weight. Heavy in weight.
8. Fuel (Petrol) costlier. Fuel (Diesel) cheaper.
9. Petrol being volatile is dangerous. Diesel is not dangerous as it is non-volatile.
10. Pre-ignition possible. Pre-ignition not possible.
11. Works on Otto cycle. Works on diesel cycle.
12. Less dependable. More dependable.
13. Used in cars and motor cycles. Used in heavy duty vehicles like trucks,
buses and heavy machinery.
224 POWER PLANT ENGINEERING
Surge tank
Air filter
Fuel day tank Fuel injection
Diesel engine pump
Jacket
Compressed Exhaust line water
air bottle To muffler pump
Fuel filter Generator
Oil
Air pump
compressor Oil cooler
Aux. oil pump
Lubricating oil tank Strainer
Cooling
Oil purifier tower
exchanger
Over flow Transfer pump
Heat
Fuel tank
Pump
4.13.1. Engine The air system begins with an intake located outside
the building provided with a filter to catch dirt which would
This is the main component of the plant which develops
otherwise cause excessive wear in the engine. The filters
the required power. It is generally directly coupled to the
may be of dry or oil bath. Electrostatic precipitator filters
generator as shown in Fig. 4.7.
can also be used. Oil impingement type of filter consists of
4.13.2. Air Intake System a frame filled with metal shavings which are coated with a
special oil so that the air in passing through the frame and
The air intake system conveys fresh air through pipes or
ducts to : (i) Air intake manifold of four stroke engines, (ii) being broken up into a number of small filaments comes
The scavenging pump inlet of a two stroke engine, and (iii) into contact with the oil whose property is to sieze and
hold any dust particles being carried by the air. The dry
The supercharger inlet of a supercharged engine.
type of filter is made of cloth, felt, glass wool etc. In case of
oil bath type of filter the air is swept over or through a pool
of oil so that the particles of dust become coated. Light
Air filter weight steel pipe is the material for intake ducts. In some
Louvers
2. Air should not be taken from a confined space 4.13.4. Fuel System
otherwise air pulsations can cause serious vibration
Refer to Fig. 4.10.
problems.
3. The air-intake line used should neither have too The fuel oil may be delivered at the plant site by
small a diameter nor should be too long, otherwise trucks, railroad tank cars or barge and tankers. From tank
there may crop up engine starvation problem. car or truck the delivery is through the unloading facility
to main storage tanks and then by transfer pumps to small
4. Air intake filters may not be located close to the
service storage tanks known as engine day tanks. Large
roof of the engine room otherwise pulsating air flow
storage capacity allows purchasing fuel when prices are
through the filters can cause serious vibrations of
low. The main flow is made workable and practical by
the roof.
arranging the piping equipment with the necessary heaters,
5. Air intake filters should not be located in an
by passes, shut-offs, drain lines, relief valves, strainers and
inaccessible location.
filters, flow meters and temperature indicators. The actual
4.13.3. Exhaust System flow plans depend on type of fuel, engine equipment, size
of the plant etc. The tanks should contain manholes for
Refer to Fig. 4.9. The purpose of the exhaust system is
internal access and repair, fill lines to receive oil, vent lines
to discharge the engine exhaust to the atmosphere outside
to discharge vapours, overflow return lines for controlling
the building. The exhaust manifold connects the engine
oil flow and a suction line to withdraw oil. Coils heated by
cylinder exhausts outlet to the exhaust pipe which is
hot water or steam reduce oil viscosity to lower pumping
provided with a muffler to reduce pressure in the exhaust
power needs.
line and eliminate most of the noise which may result if
gases are discharged directly into the atmosphere.
Fuel unloading
line
Gases out
Bulk Fuel
Silencer storage oil
Expansion pumps
joint Exhaust manifold
Strainers
Meters
Diesel engine
Day tanks
3. Before being covered, all oil lines should be put Atomisation of fuel oil has been secured by (i) air
under air pressure and the joints tested with soap blast, and (ii) pressure spray. Early diesel engines used air
solution. Small air leaks into the line can be the fuel injection at about 70 bar. This is sufficient not only to
source of exasperating operating difficulties and are inject the oil, but also to atomise it for a rapid and through
hard to remedy once the plant is in operation. combustion. The expense of providing an air compressor
4. The piping between filter and the engine should be and tank led to the development of “solid” injection, using
thoroughly oil flushed before being first placed in a liquid pressure of between 100 and 200 bar which is
service. sufficiently high to atomise the oil it forces through spray
5. Considerable importance should be given for nozzles. Great advances have been made in the field of
cleanliness in handling bulk fuel oil. Dirt particles solid injection of the fuel through research and progress in
will ruin the fine lap of injection pumps or plug the fuel pump, spray nozzles, and combustion chamber design.
injection nozzle orifices. So high-grade filters are of 1. Common-rail injection system :
paramount importance to the diesel oil supply
Two types of common-rail injection systems are
system.
shown in Figs. 4.11 and 4.12 respectively.
Fuel Injection system
Refer to Fig. 4.11. A single pump supplies high-
The mechanical heart of the Diesel engine is the pressure fuel to header, a relief valve holds pressure
fuel injection system. The engine can perform no better than constant. The control wedge adjusts the lift of mechanical
its fuel injection system. A very small quantity of fuel must operated valve to set amount and time of injection.
be measured out, injected, atomised, and mixed with
combustion air. The mixing problem becomes more
Mechanically
difficult—the larger the cylinder and faster the rotative actuated
speed. Fortunately the high-speed engines are the small- spray
bore automotive types ; however, special combustion valve
arrangements such as precombustion chambers, air cells,
etc. are necessary to secure good mixing. Engines driving
electrical generators have lower speeds and simple Fuel lines to
combustion chambers. other cylinders
Nozzles
Fuel lines to
other cylinders
Control
lever
Control
Accumulator rod
Cams Cam
Pump drive
shaft
Controlled Primary pump
pressure
pump
Fuel from Fig. 4.14. Distributor system.
day tank
Fuel Pump
Fig. 4.12
Refer to Fig. 4.15. L is the plunger which is driven
2. Individual pump injection system : by a cam and tappet mechanism at the bottom (not shown
Refer to Fig. 4.13. In this system an individual pump in Fig. 4.15), B is the barrel in which the plunger
or pump cylinder connects directly to each fuel nozzle. reciprocates. There is the rectangular vertical groove in
Pump meters charge and control injection timing. Nozzles the plunger which extends from top to another helical
contain a delivery valve actuated by the fuel-oil pressure. groove. V is the delivery valve which lifts off its seat under
the liquid fuel pressure and against the spring force (S).
The fuel pump is connected to fuel atomiser through the
passage P. SP and Y are the spill and supply ports
respectively. When the plunger is at its bottom stroke the
ports SP and Y are uncovered (as shown in Fig. 4.15) oil
from low pressure pump (not shown) after being filtered is
Injection forced into the barrel. When the plunger moves up due to
nozzles
cam and tappet mechanism, a stage reaches when both
the ports SP and Y are closed and with the further upward
High-pressure
fuel lines Pump with an movement of the plunger the fuel gets compressed. The
individual cylinder high pressure thus developed lifts the delivery valve off its
for each nozzle seats and fuel flows to atomiser through the passage P.
Control With further rise of the plunger, at a certain moment, the
rack port SP is connected to the fuel in the upper part of the
Pump plunger through the rectangular vertical groove by the
camshaft helical groove, as a result of which a sudden drop in
pressure occurs and the delivery valve falls back and
occupies its seat against the spring force. The plunger is
Fig. 4.13. Individual pump injection system.
rotated by the rack R which is moved in or out by the
3. Distributor system : governor. By changing the angular position of the helical
Refer to Fig. 4.14. In this system, the fuel is metered groove (by rotating the plunger) of the plunger relative to
at a central point ; a pump pressurises, meters the fuel the supply port, the length of stroke during which the oil is
and times the injection. From here, the fuel is distributed delivered can be varied and thereby quantity of fuel
delivered to the engine is also varied accordingly.
228 POWER PLANT ENGINEERING
Spring (S)
Adjusting
screw (AS)
Spring cap
Delivery Valve (V) nut (SCN)
Spring (S)
Passages (A)
Barrel (B) (A, B)
Fuel from
fuel pump
Spindle (E)
Passage (C)
Cap nut
(CN)
the metals will loose their characteristics and piston will Advantages :
expand considerably and sieze the liner. Of course 1. The design of the engine becomes simpler as no
theoretically thermal efficiency of the engine will improve water jackets are required. The cylinder can be
without cooling but actually the engine will sieze to run. If of identical dimensions and individually
the cylinder wall temperature is allowed to rise above a detachable and therefore cheaper to renew in
certain limit, about 65°C, the lubricating oil will begin to case of accident etc.
evaporate rapidly and both cylinder and piston may be 2. Absence of cooling pipes, radiator etc. makes the
damaged. Also high temperature may cause excessive cooling system simpler.
stress in some parts rendering them useless for further
3. No danger of coolant leakage etc.
operation. In view of this, part of the heat generated inside
the engine cylinder is allowed to be carried away by the 4. The engine is not subjected to freezing troubles
cooling system. Thus cooling system is provided on an etc. usually encountered in case of water cooled
engine for the following reasons : engine.
1. The even expansion of piston in the cylinder may 5. The weight per B.P. of the air-cooled engine is
result in seizure of the piston. less than that of water-cooled engine.
2. High temperatures reduce strength of piston and 6. In this case engine is rather a self contained unit
cylinder liner. as it requires no external components e.g.
radiator, headers, tank etc.
3. Overheated cylinder may lead to pre-ignition of
the charge, in case of spark ignition engine. 7. Installation of air-cooled engines is easier.
4. Physical and chemical changes may occur in Disadvantages :
lubricating oil which may cause sticking of piston 1. Their movement is noisy.
rings and excessive wear of cylinder. 2. Non-uniform cooling.
Almost 25 to 35 per cent of total heat supplied in 3. The output of air-cooled engine is less than that
the fuel is removed by the cooling medium. Heat carried of a liquid-cooled engine.
away by lubricating oil and heat lost by radiation amounts
4. Maintenance is not easy.
3 to 5 per cent of total heat supplied.
5. Smaller useful compression ratio.
There are mainly two methods of cooling I.C. engine:
1. Air cooling 2. Liquid cooling. 2. Liquid cooling
In this method of cooling engines, the cylinder walls
1. Air cooling
and heads are provided with jackets through which the
In this method, heat is carried away by the air cooling liquid can circulate. The heat is transferred from
flowing over and around the engine cylinder. It is used in cylinder walls to the liquid by convection and conduction.
scooters, motorcycles etc. Here fins are cast on the cylinder The liquid becomes heated in its passage through the
head and cylinder barrel which provide additional jackets and is itself cooled by means of an air-cooled radiator
conductive and radiating surface (Fig. 4.17). The fins are system. The heat from liquid in turn is transferred to air.
arranged in such a way that they are at right angles to the
cylinder axis. Various methods are used for circulating the water
around the cylinder and cylinder head. These are :
1. Thermo-syphon cooling
Fins
2. Forced or pump cooling
3. Cooling with thermostatic regulator
4. Pressurised water cooling
5. Evaporative cooling.
1. Thermo-syphon cooling :
The basis of this type of cooling is the fact that water
becomes light on heating. Fig. 4.18 shows the thermo-
syphon cooling arrangement. The top of radiator is
connected to the top of water jacket by a pipe and bottom
of the radiator to the bottom of the water jacket. Water
travels down the radiator across which air is passed to cool
it. The air flow can take place due to vehicle motion or a
fan can be provided for the purpose.
Fig. 4.17. Air cooling.
230 POWER PLANT ENGINEERING
Radiator core
This system has the advantage that it is quite simple The advantage of forced system is that cooling is
and automatic and is without any water pump unless there ensured under all conditions of operation.
is leak, there is nothing to get out of order. This system entails the following demerits :
The major short coming of this system is that cooling (i) The cooling is independent of temperature. This
depends only on the temperature and is independent of the may, under certain circumstances, result in overcooling the
engine speed. The rate of circulation is slow and insufficient.
engine. (ii) While moving uphill the cooling requirement is
The circulation of water starts only after the engine has
increased because more fuel is burned. However, the coolant
become hot enough to cause thermo-syphon action. This
circulation is reduced which may result in over-heating
system requires that the radiator be above the engine for
the engine. (iii) As soon as the engine is stopped the cooling
gravity flow of water to engine.
also ceases. This is undesirable because cooling must
Thermo-syphon system is not widely used at present.
continue till the temperatures are reduced to normal
2. Forced or pump system : values.
Refer to Fig. 4.19. In this system, a pump is used to 3. Thermostat cooling :
cause positive circulation of water in the water jacket. Too lower cylinder barrel temperature, may result
Usually the pump is belt driven from the engine. in severe corrosion damage due to condensation of acids
on the barrel wall. To avoid such a situation it is customary
to use a thermostat (a temperature controlling device) to
stop flow of coolant below a pre-set cylinder barrel
temperature. Most modern cooling system employ a
thermo-static device which prevents the water in the engine
jacket from circulating through the radiator for cooling until
its temperature has reached to a value suitable for efficient
engine operation.
Fig. 4.20 shows a systematic diagram of a
thermostatically controlled cooling system. Also shown is
a typical thermostat (Fig. 4.21). It consists of bellows which
are made of thin copper tubes, partially filled with a volatile
liquid like ether or methyl alcohol. The volatile liquid
changes into vapour at the correct working temperature,
thus creating enough pressure to expand the bellows. The
temperature at which the thermostat operates is set by
the manufacturers and cannot be altered. The movement
of the bellows opens the main valve in the ratio of
temperature rise, increasing or restricting the flow of water
from engine to the radiator. Hence when the normal
Fig. 4.19. Forced or pump system.
DIESEL ENGINE POWER PLANT 231
Bellows
Cylinder
Water block
In
Steam
Water
3. More even cooling of cylinder barrels and heads (iv) Piston rings and cylinder walls.
due to jacketing makes it easier to reduce the (v) Timing gears.
cylinder head and valve seating temperature. (vi) Camshaft and cam shaft bearings.
4. In case of water-cooled engine installation is not
(vii) Valve mechanism.
necessary at the front of mobile vehicles,
(viii) Valve guides, valve tappets and rocker arms.
aircrafts etc. as the cooling system can be
conveniently located wherever required. This is Various lubrication systems used for I.C. engines
not possible in case of air-cooled engines. may be classified as :
5. The size of the engine does not involve serious 1. Wet sump lubrication system.
problem as far as design of cooling system is 2. Dry sump lubrication system.
concerned. In case of air-cooled engines
3. Mist lubrication system.
particularly in high horse power range difficulty
is encountered in circulation of required quantity 1. Wet sump lubrication system
of air for cooling purposes. These systems employ a large capacity oil sump at
Disadvantages : the base of crankchamber, from which the oil is drawn by
a low pressure oil pump and delivered to various parts. Oil
1. This is dependent system in which supply of
then gradually returns back to the sump after serving the
water/liquid for circulation in the jacket is
purpose.
required.
2. Power absorbed by the pump for water (a) Splash system: Refer to Fig. 4.23. This system
circulation is considerably higher than that for is used on some small four stroke stationary engines. In
cooling fans. this case the caps on the big end bearings of connecting
rods are provided with scoops which, when the connecting
3. In the event of failure of cooling system serious
rod is in the lowest position, just dip into oil troughs and
damage may be caused to the engine.
thus directs the oil through holes in the caps to the big end
4. Cost of system is considerably high.
bearings. Due to splash of oil it reaches the lower portion
5. System requires considerable attention for the
of the cylinder walls, crankshaft and other parts requiring
maintenance of various parts of system.
lubrication. Surplus oil eventually flows back to the oil
4.13.6. Lubrication Systems sump. Oil level in the troughs is maintained by means of a
oil pump which takes oil from sump, through a filter.
Lubrication is the admittance of oil between two surface
having relative motion. The purpose of lubrication may be Splash system is suitable for low and medium speed
one or more of the following : engines having moderate bearing load pressures. For high
performance engines, which normally operate at high
1. To reduce friction and wear between the parts
bearing pressures and rubbing speeds this system does not
having relative motion.
serve the purpose.
2. To cool the surfaces by carrying away heat
(b) Semi-pressure system: This method is a
generated due to friction.
combination of splash and pressure systems. It incorporates
3. To seal a space adjoining the surfaces such as the advantages of both. In this case main supply of oil is
piston rings and cylinder liner. located in the base of crank-chamber. Oil is drawn from
4. To clean the surface by carrying away the carbon the lower portion of the sump through a filter and is
and metal particles caused by wear. delivered by means of a gear pump at pressure of about 1
5. To absorb shock between bearings and other bar to the main bearings. The big end bearings are
parts and consequently reduce noise. lubricated by means of a spray through nozzles. Thus oil
also lubricates the cams, crankshaft bearings, cylinder
The main parts of an engine which need lubrication
walls and timing gears. An oil pressure gauge is provided
are as given below :
to indicate satisfactory oil supply.
(i) Main crankshaft bearings.
The system is less costly to install as compared to
(ii) Big-end bearings. pressure system. It enables higher bearing loads and engine
(iii) Small end or gudgeon pin bearings. speeds to be employed as compared to splash system.
DIESEL ENGINE POWER PLANT 233
Piston
Pressure gauge
1 2 3 4 5 6 7 8
Oil filter
Oil pump Strainer
Oil pan
This system finds favour from most of the engine 3. Mist lubrication system
manufacturers as it allows high bearing pressure and This system is used for two stroke cycle engines. Most
rubbing speeds. of these engines are crankcharged, i.e. they employ
crankcase compression and thus, are not suitable for cran
case lubrication. These engines are lubricated by adding 2
to 3 per cent lubricating oil in the fuel tank. The oil and
Filter fuel mixture is induced through the carburettor. The
gasoline is vaporised ; and the oil in the form of mist, goes
To bearings
via crankcase into the cylinder. The oil which impinges on
Pressure the crankcase walls lubricates the main and connecting
regulator
rod bearings, and rest of the oil which passes on the cylinder
during charging and scavanging periods, lubricates the
Oil pump Breather
piston, piston rings and the cylinder.
Advantages:
Oil strainer 1. System is simple.
2. Low cost (because no oil pump filter etc. are
required).
Engine Disadvantages:
Drain plug crankcase 1. A portion of the lubricating oil invariably burns
Wet sump
in combustion chamber. This bearing oil when
burned, and still worse, when partially burned
Fig. 4.25. Wet sump lubrication system. in combustion chamber leads to heavy exhaust
The general arrangement of wet sump lubrication emissions and formation of heavy deposit on
system is shown in Fig. 4.25. In this case oil is always piston crown, ring grooves and exhaust port
contained in the sump which is drawn by the pump through which interferes with the efficient engine
a strainer. operation.
2. Dry sump lubrication system 2. One of the main functions of lubricating oil is
the protection of anti-friction bearings etc.
Refer to Fig. 4.26. In this system, the oil from the
against corrosion. Since the oil comes in close
sump is carried to a separate storage tank out side the
contact with acidic vapours produced during the
engine cylinder block. The oil from sump is pumped by
combustion process, it rapidly loses its anti-
means of a sump pump through filters to the storage tank.
corrosion properties resulting in corrosion
Oil from storage tank is pumped to the engine cylinder
damage of bearings.
through oil cooler. Oil pressure may varies from 3 to 8 kgf/
cm2. Dry sump lubrication system is generally adopted for 3. For effective lubrication oil and fuel must be
high capacity engines. thoroughly mixed. This requires either separate
mixing prior to use or use of some additive to
Vent give the oil good mixing characteristics.
4. Due to higher exhaust temperature and less
Pressure efficient scavening the crank case oil is diluted.
Oil cooler
relief valve
To In addition some lubricating oil burns in
bearing Supply combustion chamber. This results in 5 to 15 per
Oil pump tank cent higher lubricant consumption for two stroke
engine of similar size.
Engine crankcase Bypass 5. Since there is no control over the lubrication oil,
pressure relief once introduced with fuel, most of the two stroke
valve engines are over-oiled most of the time.
Dry sump
4.13.7. Engine Starting System
Strainer Filter The following three are the commonly used starting
systems in large and medium size engines :
Scavenging 1. Starting by an auxiliary engine.
pump
2. Use of electric motors or self starters.
Fig. 4.26. Dry sump librication system. 3. Compressed air system.
DIESEL ENGINE POWER PLANT 235
1. Starting by an auxiliary engine (generally fuel and oil pressures etc. The lubrication of generator and
petrol driven) : excited bearings should also be checked.
In this system an auxiliary engine is mounted close 5. Increase the engine speed gradually till it
to the main engine and drives the latter through a clutch synchronizes with the station bus-bar.
and gears. The clutch is first disengaged and the auxiliary 6. Connect the generator to the bus-bar when it is
engine started by hand or by a self starter motor. When it in synchronism and increase the engine speed till it begins
has warmed up and runs normally the drive gear is engaged to share the desired load.
through the clutch, and the main engine is cranked for
starting. To avoid the danger of damage to drive gear it is Stopping of engines :
desirable to have an over-running clutch or starter type 1. Reduce the speed of the engine gradually until
drive. practically no power is delivered by the alternator.
2. Disconnect the unit from the bus and allow the
2. Use of electric motors or self starters :
engine to idle for a few minute, and then stop it in confirmity
These are employed for small diesel and gasoline with the instructions detailed by the manufacturers.
engines. A storage battery of 12 to 36 volts is used to supply
power to an electric motor which is geared to the flywheel 4.13.8. Governing System
with arrangement for automatic disengagement after the The function of the governing system is to maintain the
engine has started. The motor draws a heavy current and speed of the engine constant irrespective of load on the
is designed to be engaged continuously for about 30 seconds plant. This is done generally by varying the fuel supply to
only, after which it is required to cool off for a minute or so, the engine according to the load.
and then re-engaged. This is done till the engine starts up.
When the engine is running a small D.C. generator on the
engine serves to charge the battery.
4.14. COMBUSTION PHENOMENON IN C.I.
ENGINES
3. Compressed air system :
The compressed air system is commonly used for The process of combustion in the compression ignition (C.I.)
starting large diesel engines employed for stationary power engine is fundamentally different from that in a spark-
plant service. Compressed air at about 17 bar supplied from ignition engine. In C.I. engine combustion occurs by the
an air tank or bottle is admitted to a few of the engine high temperature produced by the compression of the air,
cylinders making them work like reciprocating air motors i.e. it is an auto-ignition. For this a minimum compression
to run the engine shaft. Fuel is admitted to the remaining ratio of 12 is required. The efficiency of the cycle increases
cylinders and ignites in the normal way causing the engine with higher values of compression ratio but the maximum
to start. The air bottle or tank is charged by a motor or pressure reached in the cylinder also increases. This
gasoline engine driven compressor. The system includes requires heavier construction. The upper limit of
the following : compression ratio in a C.I. engine is due to mechanical
factor and is a compromise between high efficiency and
(i) Storage tank/vessel
low weight and cost. The normal compression ratios are in
(ii) A safety valve the range of 14 to 17, but may be upto 23. The air-fuel
(iii) Interconnecting pipe work. ratios used in the C.I. engine lie between 18 and 25 as
Methods of Starting and Stopping Engines against about 14 in the S.I. engine, and hence C.I. engines
Although starting procedure may differ from engine are bigger and heavier for the same power than S.I. engines.
to engine but some common steps are listed below : In the C.I. engine, the intake is air alone and the
fuel is injected at high pressure in the form of fine droplets
Starting of engines : near the end of compression. This leads to delay period in
1. In case of electric motor starting check the the C.I. engine, is greater than that in the S.I. engine. The
condition of storage battery. If compressed air system is exact phenomenon of combustion in the C.I. engine is
used, then air pressure may be checked first and the air explained below.
system inspected for possible leakage. Each minute droplet of fuel as it enters the highly
2. As prescribed by the manufactures, all necessary heated air of engine cylinder is quickly surrounded by an
checks for fuel, lubricating oil and cooling water should be envelope of its own vapour and this, in turn, and an
made. appreciable interval is inflamed at the surface of the
3. Crank the engine after ensuring that all load is envelope. To evaporate the liquid, latent heat is abstracted
put off and decompression device is in use, and then let it from the surrounding air which reduces the temperature
start. of the thin layer of air surrounding the droplet, and some
4. For a few minutes run the engine at slow speed time must elapse before this temperature can be raised
and observe the working of fuel pumps, lubricating systems, again by abstracting heat from the main bulk of air in this
236 POWER PLANT ENGINEERING
vicinity. As soon as this vapour and the air in actual contact 1. Ignition delay period.
with it reach a certain temperature, ignition will take place. 2. Period of rapid or uncontrolled combustion.
Once ignition has been started and a flame established 3. Period of controlled combustion.
the heat required for further evaporation will be supplied
The third phase is followed by ‘after burning’ (or
from that released by combustion. The vapour would be
burning on the expansion stroke), which may be called the
burning as fast as it can find fresh oxygen, i.e., it will depend
fourth phase of combustion.
upon the rate at which it is moving through the air or the
air is moving past it. 1. Ignition delay period: The delay period is
counted from the start of injection to the point where the
In the C.I. engine, the fuel is not fed in at once but
p- combustion curve departs from air compression (or no
is spread over a definite period. The first arrivals meet air
ignition or motoring) curve. The delay period can be roughly
whose temperature is only little above their self-ignition
sub-divided into physical delay and chemical delay. The
temperature and the delay is more or less prolonged. The
period of physical delay is the time between the beginning
later arrivals find air already heated to a far higher of injection and the attainment of chemical reaction
temperature by the burning of their predecessors and conditions. In the physical delay period, the fuel is atomized,
therefore light up much more quickly, almost as they issue vaporized, mixed with air, and raised in temperature. In
from the injector nozzle, but their subsequent progress is the chemical delay period reaction starts slowly and then
handicapped for there is less oxygen to find. accelerates until inflammation or ignition takes place (it
If the air within the cylinder were motionless, only may be noted that the ignition delay in the S.I. engine is
a small proportion of the fuel would find sufficient oxygen, essentially equivalent to the chemical delay in the C.I.
for it is impossible to distribute the droplets uniformly engine).
throughout the combustion space. Therefore some air The delay period exerts a great influence in the C.I.
movement is absolutely essential, as in the S.I. engine. But engine combustion phenomenon. It is clear that the
there is a fundamental difference between the air pressure reached during the second stage will depend upon
movements in the two types of engines. In the S.I. engine the duration of the delay period ; the longer the delay, the
we call it turbulence and mean a confusion of whirls and more rapid and higher the pressure rise, since more fuel
eddies with no general direction of flow, (to break up the will be present in the cylinder before the rate of burning
surface of the flame front, and to distribute the shreds of comes under control. This causes rough running and may
flame throughout an externally prepared combustible cause diesel knock. Therefore we must aim to keep the delay
mixture). In the C.I. engine we call it air swirl and mean period as short as possible, both for the sake of smooth
an orderly movement of the whole body of the air, with or running and in order to maintain control over the pressure
without some eddying or turbulence, so as to bring a changes. But some delay period is necessary otherwise the
continuous supply of fresh air to each burning droplet and droplets would not be dispersed in the air for complete
sweep away the products of combustion which otherwise combustion. However, the delay period imposed upon is
tend to suffocate it. greater than what is needed and the designer’s efforts are
Three phases of C.I. engine combustion to shorten it as much as possible.
In the C.I. engine, combustion may be considered 2. Period of rapid or uncontrolled combustion:
in three distinct stages as shows in Fig. 4.27. The second stage of combustion in C.I. engines, after the
delay period, is the period of rapid or uncontrolled
90 combustion. This period is counted from the end of the delay
period to the point of maximum pressure on the indicator
80
diagram. In this second stage of combustion, the rise of
70 Start of Compression pressure is rapid because during the delay period the
combustion pressure droplets of fuel have had time to spread themselves out
p (bar) ¾¾®
60
over a wide area and they have fresh air all around them.
50 Injection About one-third of heat is evolved during this process.
starts
40 The rate of pressure rise depends on the amount of
0.001 sec.
fuel present at the end of delay period, degree of turbulence,
30
1 2 3 4 fineness of atomization and spray pattern.
20 3. Period of controlled combustion: At the end
Injection of second stage of combustion, the temperature and
10 Atmospheric
pressure, are so high that the fuel droplets injected in the
third stage burn almost as they enter and any further
120 100 80 60 40 20 TDC 20 40 60 80 100 120 pressure rise can be controlled by purely mechanical means,
Time, degrees of crankshaft rotation (q) i.e. by the injection rate. The period of controlled combustion
is assumed to end at maximum cycle temperature. The heat
Fig. 4.27. Combustion phenomenon of C.I. engine.
DIESEL ENGINE POWER PLANT 237
evolved by the end of controlled combustion is about 70 to rate of pressure rise and high maximum pressure which
80 per cent. may cause knocking in diesel engines. A long delay period
4. After burning: The combustion continues even not only increases the amount of fuel injected by the
after the fuel injection is over, because of poor distribution moment of ignition but also improves the homogeneity of
of fuel particles. This burning may continue in the the fuel-air mixture and its chemical preparedness for
expansion stroke upto 70 to 80° of crank travel from T.D.C. explosion type self-ignition similar to detonation is S.I.
This continued burning, called the after burning, may be engines.
considered as the fourth stage of the combustion. The total The following are the differences in the knocking
heat evolved by the end of entire combustion process is 95 phenomena of the S.I. and C.I. engines :
to 97% ; 3 to 5% of heat goes as unburned fuel in exhaust.
1. In the S.I. engine, the detonation occurs near
In the p-V diagram, the stages of combustion are
the end of combustion whereas in the C.I. engine
not seen because of little movement of piston with crank
detonation occurs near the beginning of
angle at the end and reversal of stroke. So for studying the
combustion.
combustion stages, therefore, a pressure-crank angle or
time, p- or p-t diagram is invariable used. In the actual 2. The detonation in the S.I. engine is of a
diagram, the various stages of combustion look merged, homogeneous charge causing very high rate of
yet the individual stage is distinguishable. pressure rise and very high maximum pressure.
In the C.I. engine, the fuel and air are imperfectly
4.15. DELAY PERIOD (OR IGNITION LAG) mixed and hence the rate of pressure rise is
IN C.I. ENGINES normally lower than that in the detonating part
of the charge in the S.I. engine.
—In C.I. (compression ignition) engine, the fuel which is 3. In the C.I. engine the fuel is injected into the
in atomised form is considerably colder than the hot cylinder only at the end of the compression
compressed air in the cylinder. Although the actual ignition stroke, there is no question of pre-ignition as in
is almost instantaneous, an appreciable time elapses before
S.I. engine.
the combustion is in full progress. This time occupied is
called the delay period or ignition lag. It is time immediately 4. In the S.I. engine, it is relatively easy to
following injection of the fuel during which the ignition distinguish between knocking and non-knocking
process is being initiated and the pressure does not rise operation as the human ear easily finds the
beyond the value it would have due to compression of air : distinction.
—The delay period extends for about 13°, movement
of the crank. The time for which it occurs decreases with 4.17. CETANE NUMBER
increase in engine speed. —The cetane rating of a diesel fuel is a measure of its ability
The delay period depends upon the following : to auto-ignite quickly when it is injected into the compressed
(i) Temperature and pressure in the cylinder at the and heated air in the engine. Though ignition delay is
time of injection. affected by several engine design parameters such as
(ii) Nature of the fuel mixture strength. compression ratio, injection rate, injection time, inlet air
(iii) Relative velocity between the fuel injection and temperature etc., it is also dependent on hydrocarbon
air turbulence. composition of the fuel and to some extent on its volatility
(iv) Presence of residual gases. characteristic. The cetane number is a numerical measure
of the influence the diesel fuel has in determining the ignition
(v) Rate of fuel injection.
delay. Higher the cetane rating of the fuel lesser is the
(vi) To small extent the finess of the fuel spray. propensity for diesel knock.
The delay period increases with load but is not much —The procedure for obtaining cetane number is
affected by injection pressure. similar to that for obtaining the octane number of petrols.
—The delay period should be as short as possible Reference mixtures of cetane (C16H34) (high ignitability),
since a long delay period gives a more rapid rise in pressure and -methyl-naphthalene (C11H10) (low ignitability), are
rise and thus causes knocking. used. The mixture is made by volume and the ignitability
of the test fuel is quoted as the percentage of cetane in the
4.16. DIESEL KNOCK reference mixture which has the same ignitability.
If the delay period in C.I. engines is long a large amount of —For higher speed engines, the cetane number
fuel will be injected and accumulated in the chamber. The required is about 50, for medium speed engines about 40,
auto-ignition of this large amount of fuel may cause high and for slow speed engines about 30.
238 POWER PLANT ENGINEERING
the air is forced into the major and minor chambers of the 3. Increasing the density of the charge, such that a
energy cell. When the fuel is injected through the pintle greater mass of charge is introduced into the
type nozzle, part of the fuel passes across the main same volume or same total piston displacement.
combustion chamber and enters the minor cell, where it is The last method of increasing the air capacity of an
mixed with the entering air. Combustion first commences engine is widely used, and is termed supercharging.
in the main combustion chamber where the temperature The apparatus used to increase the air density is
is higher, but the rate of burning is slower in this location, known as a supercharger. It is merely a compressor which
due to insufficient mixing of the fuel and air. The burning provides a denser charge to the engine, thereby enabling
in the minor cell is slower at the start, but due to better the consumption of a greater mass of charge with the same
mixing, progresses at a more rapid rate. The pressures built total piston displacement. During the process of
up in the minor cell, therefore, force the burning gases out compressing the charge, the supercharger produces the
into the main combustion chamber, thereby creating added following effects :
turbulence and producing better combustion in this
(i) Provides better mixing of the air-fuel mixture. The
chamber. In the mean time, pressure is built up in the major
turbulent effect created by the supercharger assists in
cell, which then prolongs the action of the jet stream
additional mixing of the fuel and air particles. The
entering the main chamber, thus continuing to induce
arrangement of certain types of superchargers, particularly
turbulence in the main chamber.
the centrifugal type, also encourages more even distribution
Summarily it may be said that a particular of the charge to the cylinders.
combustion chamber design must be chosen to perform a
(ii) The temperature of the charge is raised as it is
given job. No one combustion chamber can produce an
compressed, resulting in a higher temperature within the
ultimate of performance in all tasks. The design of the
cylinders. This is partially beneficial in that it helps to
chamber must be based on a compromise, after full
produce better vapourisation of fuel (in case of S.I. engines)
considerations of the following factors : (i) Heat lost to
but deterimental in that it tends to lessen the density of
combustion chamber walls, (ii) Injection pressure, (iii)
the charge. The increase in temperature of the charge also
Nozzle design, (iv) Maintenance, (v) Ease of starting, (vi)
effects the detonation of the fuel.
Fuel requirement, (vii) Utilisation of air, (viii) Weight
relation of engine to power output, (ix) Capacity for variable Supercharging tends to increase the possibility of
speed operation. detonation in a S.I. engine and lessen the possibility in a
C.I. engine.
4.19. SUPERCHARGING (iii) Power is required to drive the supercharger.
This is usually taken from the engine and thereby removes,
The purpose of supercharging is to raise the volumetric from over-all engine output, some of the gain in power
efficiency above that value which can be obtained by normal obtained through supercharging.
aspiration.
Compressors used are of the following three types :
The engine is an air pump. Increasing the air
(i) Positive displacement type used with many
consumption permits greater quantities of fuel to be added,
reciprocating engines in stationary plants, vehicles and
and results in a greater potential output. The indicated
marine installations.
power produced is almost directly proportional to the engine
(ii) Axial flow type seldom used to supercharge
air consumption. While brake power is not so closely related
reciprocating engines, it is widely used as the compressor
to air consumption, it is nevertheless, dependent upon the
unit of the gas turbines.
mass of air consumed. It is desirable, then, that the engine
takes in greatest possible mass of air. (iii) Centrifugal type widely used as the
supercharger for reciprocating engines, as well as
Three possible methods which might be utilized to
compressor for gas turbines. It is almost exclusively used
increase the air consumption of an engine are :
as the supercharger with reciprocating power plants for
1. Increasing the piston displacement, but this
aircraft because it is relatively light and compact, and
increases the size and weight of the engine, and
produces continuous flow rather than pulsating flow as in
introduces additional cooling problems.
some positive displacement types.
2. Running the engine at higher speeds, which
results in increased fluid and mechanical friction Supercharging of S.I. engines
losses, and imposes greater inertia stresses on —An ideal p-V diagram for a supercharged constant
engine parts. volume cycle is shown in Fig. 4.29.
240 POWER PLANT ENGINEERING
Apart from increases in pressures over the un- Unlike S.I. engines supercharging does not result
supercharged cycle the main difference is that pumping in any combustion problem, rather it improves combustion
loop (1-5-6-7-1) is now a positive one. The net indicated in diesel engine. Increase in pressure and temperature of
power (I.P.) is obtained by adding the contribution from the intake air reduces significantly delay and hence the
pumping loop to that of the power loop (1-2-3-4-1). The gas rate of pressure rise resulting in a better, quieter and
is exhausted from the cylinder at the pressure of point 4 smoother combustion. This improvement in combustion
on the diagram. This value is high compared with allows a poor quality fuel to be used in a diesel engine and
atmospheric pressure and a considerable amount of energy it is also not sensitive to the type of fuel used. The increase
is lost by allowing the gas to blow down in this way. in intake temperature reduces volumetric and thermal
The power required to drive a blower mechanically efficiency but increase in density due to pressure
connected to the engine must be subtracted from the engine compensates for this and intercooling is not necessary except
output to obtain the net brake power (B.P.) of the for highly supercharged engines.
supercharged engine. If an unsupercharged engine is supercharged it will
FG area 12341 area 15671IJ increase the reliability and durability of the engine due to
Then, Im.e.p. =
H length of diagram K smoother combustion and lower exhaust temperatures. The
degree of supercharging is limited by thermal and
× spring number ...(4.1) mechanical load on the engine and strongly depends on the
and brake power (B.P.) = (mech. × I.P.) – (power required
type of supercharger used and design of the engine.
to drive blower)
Effects of supercharging on performance of
(for mechanical driven blowers only) ...(4.2)
the engine
(i) As far as S.I. engines are concerned,
1. The ‘power output’ of a supercharged engine is
supercharging is employed only for ‘aircraft’ and ‘racing
higher than its naturally aspirated counterpart.
car engines’. This is because the increase in supercharging
pressure increases the tendency to detonate. 2. The ‘mechanical efficiencies’ of supercharged
engines are slightly better than the naturally
p aspirated engines.
3. Inspite of better mixing and combustion due to
reduced delay a mechanically supercharged otto
engine almost always have ‘specific fuel
3 consumption’ higher than a naturally aspirated
engine.
2 3
2
4
7 1
6 5
V
Fig. 4.31 shows the effect of supercharging on power 2. During operation the lubrication system should
and fuel. work effectively and requisite pressure and temperature
11.2 maintained. The engine oil should be of the correct
specifications and should be in a fit condition to lubricate
B.m.e.p. the different parts. A watch may be kept on the
Fuel, kg/H.P./hr.
consumption of lubricating oil as this gives an indication
8.4
Power developed, B.H.P.
5.6
Unsupercharged
Supercharged 4. Air filter, oil filters and fuel filters should be
periodically serviced or replaced as recommended by the
2.8 0.272 manufacturers or if found in an unsatisfactory condition
Fuel upon inspection.
0.227 5. Periodical checking of engine compression and
firing pressures and also exhaust temperatures should be
600 1000 1400 1800 2200 2600 made.
Speed (r.p.m.) — The engine exhaust usually provides a good
B.H.P. – Brake horse power indication of satisfactory performance of the
B.m.e.p. – Brake mean effective, pressure engine. A black smoke in the exhaust is a sign of
inadequate combustion or engine over-loading.
Fig. 4.31. Effect of supercharging on power and fuel.
— The loss of compression resulting from wearing
out of moving parts lowers the compression ratio
4.20. OPERATION OF A DIESEL POWER causing inadequate combustion. These defects
PL ANT can be checked by taking indicator diagrams of
the engine after reasonable intervals.
When diesel alternator sets are put in parallel, “hunting”
or “phase swinging” may be produced due to resonance 4.21. TYPES OF DIESEL ENGINE USED FOR
unless due care is taken in the design and manufacture of
the sets. This condition occurs due to resonance between
DIESEL POWER PLANTS
the periodic disturbing forces of the engine and natural The diesel engines may be four-stroke or two stroke cycle
frequency of the system. The engine forces result from engines. The two-stroke cycle engines are favoured for diesel
uneven turning moment on the engine crank which are power plants.
corrected by the flywheel effect. “Hunting” results from the Efforts are being made to use “duel fuel engines” in
tendency of each set trying to pull the other into synchronism diesel power plants for better economy and proper use of
and is characterised by flickering of lights. available gaseous fuels in the country. The gas may be a
To ensure most economical operation of diesel en- waste product as in the case of sewage treatment
gines of different sizes when working together and sharing installations or oil fuels where the economic advantage is
load it is necessary that they should carry the same per- self evident. With the wider availability of natural gas, the
centage of their full load capacity at all times as the fuel duel fuel engines may become an attractive means of
consumption would be lowest in this condition. For best utilising gas as fuel at off-peak tariffs for the electric power
operation performance the manufacturer’s recommenda- generation.
tions should be strictly followed.
Working of Duel Fuel Engines
In order to get good performance of a diesel power
The various strokes of a duel fuel engine are as
plant the following points should be taken care of :
follows :
1. It is necessary to maintain the cooling temperature
1. Suction stroke. During this stroke air and gas
within the prescribed range and use of very cold water
are drawn in the engine cylinder.
should be avoided. The cooling water should be free from
suspended impurities and suitably treated to be scale and 2. Compression stroke. During this stroke the
corrosion free. If the ambient temperature approaches pressure of the mixture drawn is increased. Near the end
freezing point, the cooling water should be drained out of of this stroke the ‘pilot oil’ is injected into the engine cylinder.
the engine when it is kept idle. The compression heat first ignites the pilot oil and then gas
mixture.
242 POWER PLANT ENGINEERING
3. Working/power stroke. During this stroke the 1. Power and mechanical efficiency
gases (at high temperature) expand and thus power is 2. Mean effective pressure and torque
obtained. 3. Specific output
4. Exhaust stroke. The exhaust gases are released 4. Volumetric efficiency
to the atmosphere during the stroke.
5. Fuel-air ratio
4.22. LAYOUT OF A DIESEL ENGINE 6. Specific fuel consumption
7. Thermal efficiency and heat balance
POWER PL ANT
8. Exhaust smoke and other emissions
Fig. 4.32 shows the layout of a diesel engine power plant. 9. Specific weight.
1. Power and mechanical efficiency
Storage Space for future
and Exhaust (i) Indicated power. The total power developed by
Unit no. 4
shop silencer combustion of fuel in the combustion chamber is called
indicated power.
Air intake filter and
i.e., F.P. = I.P. – B.P. ...(4.3) “Relative fuel air ratio” is defined as the ratio of the
The ratio of B.P. to I.P. is called mechanical efficiency actual fuel air ratio to that of stoichiometric fuel-air ratio
i.e., Mechanical efficiency, required to burn the fuel supplied.
B.P. 6. Specific fuel consumption (s.f.c.)
mech. = ...(4.4)
I.P. It is the mass of fuel consumed per kW developed per
In MKS Units hour, and is a criterion of economical power production.
F.H.P. = I.H.P. – B.H.P. ...[4.4 (a)] mf
i.e., s.f.c. = kg/kWh.
B. H. P. B. P.
and, mech. = ...[4.4 (b)]
I. H. P. In MKS Units
mf
2. Mean effective pressure and torque s.f.c. = kg/B.H.P.-hr where mf
Mean effective pressure is defined as hypothetical B. H. P.
is the fuel consumed in kg/hr
pressure which is thought to be acting on the piston
throughout the power stroke. If it is based on I.P. it is called 7. Thermal efficiency and heat balance
indicated mean effective pressure (Im.e.p. or pmi) and if based
Thermal efficiency. It is the ratio of indicated work
on B.P. it is called brake mean effective pressure (Bm.e.p. or
done to energy supplied by the fuel.
pmi). Similarly, frictional mean effective pressure (Fm.e.p.
or pmf) can be defined as : If, m f = Mass of fuel used in kg/sec., and
Fm.e.p. = Im.e.p. – Bm.e.p. ...(4.5) C = Calorific value of fuel (lower),
The torque and mean effective pressure are related Then indicated thermal efficiency (based on I.P.),
by the engine size. I.P.
th. = ...(4.7)
Since the power (P) of an engine is dependent on its (I) f C
m
size and speed, therefore it is not possible to compare engine and brake thermal efficiency (based on B.P.)
on the basis of either power or torque. Mean effective
pressure is the true indication of the relative performance B.P.
th. = ...(4.8)
of different engines. (B) f C
m
Willan’s line for a steam engine), and is extrapolated back 2. Morse test
to cut the B.P. axis at the point L. The reading OL is taken In ‘Morse test’ (already discussed), frictional power
as the power loss of the engine at that speed. The fuel can be found by subtracting (B.P.)n from (I.P.)n
consumption at zero B.P. is given by OM ; and if the i.e., F.P. = (I.P.)n – (B.P.)n
relationship between fuel consumption and B.P. is assumed where n is the number of cylinders.
to be linear, then a fuel consumption OM is equivalent to a
power loss of OL. 3. Motoring test
In this test the engine is first run upto the desired
speed by its own power and allowed to remain under the
given speed and load conditions for sometime so that oil,
Fuel consumption ¾¾®
WORKED EXAMPLES
Example 4.1. Following data refer to a four stroke double Mechanical efficiency ; mech. :
acting diesel engine having cylinder diameter 200 mm and Area of cylinder on cover end side,
piston stroke 350 mm.
m.e.p. on cover side = 6.5 bar Acover = /4 D2 = (/4) × (0.2)2 = 0.03141 m2
m.e.p. on crank side = 7 bar Effective area of cylinder on crank end side,
Speed = 420 r.p.m. 2
Acrank = /4 (D2 – drod ) = /4 (0.22 – 0.022)
Diameter of piston rod = 20 mm
= 0.0311 m2
Dead load on the brake = 1370 N
Spring balance reading = 145 N Indicated power on cover end side,
Brake wheel diameter = 1.2 m pmi (c over ) LANk 10
Brake rope diameter = 20 mm I.P.(cover) =
6
Calculate the mechanical efficiency of the engine. 1
6.5 0.35 0.03141 420 10
Solution. Given : 2
=
Pmi(cover) = 6.5 bar, pmi(crank) = 7 bar, 6
= 25 kW
D = 0.2 m, L = 0.35 m,
Indicated power on crank end side,
N = 420 r.p.m.,
pmi ( crank ) LANk 10
drod = 20 mm = 0.02 m, I.P.(crank) =
6
W = 1370 N, S =145 N,
Db = 1.2 m, d = 0.02 m, 1
7 0.35 0.0311 420 10
= 2
1 6
k= ... 4-stroke cycle engine
2 = 26.67 kW
DIESEL ENGINE POWER PLANT 249
=
(1370 145 )(1.2 0.02) 420
60 1000
kW
or,
p2 FV I
= G J 1
1.35
= (5)1.35 = 8.78
= 32.86 kW
p1 HV K 2
= G J
4
Brake power
Suction pressure
= 14.7 kW
= 0.9 bar
or
p4 HV K3
= (5)1.3 = 8.1
2 Ex =C V4
pa on 5
= 105(57.43V3 – 7.29 × 5V3)
MN PQ
ns st.
Co
mp
ion V3
pV 1.3 res
= 105 × 20.98 V3 Nm.
5 sio
=C n 4
on
st. Mean effective pressure (theoretical),
Work done / cycle
1 pm =
3 Stroke volume (Vs )
V(m )
105 20.98V3 105 20.98V3
Fig. 4.37 = =
(V4 V3 ) 5V3 V3
Given : B.P. = 14.7 kW, p1 = 0.9 bar, = 105 × 5.245 N/m2 or 5.245 bar.
mech. = 80%, r = 5, p3 = 24 bar
B.P.
L Now, mech. =
N = 1000 r.p.m., = 1.5 I.P.
D B.P. 14.7
D = ?, L = ? I.P. = = = 18.37 kW.
mech. 0.8
250 POWER PLANT ENGINEERING
I.P.
0.4 =
14
4 41800
3600
0.4 14 41800
I.P. = = 65 kW
1 3600
V B.P.
Now, mech. =
VS = V1 – V2 I.P.
B.P.
Fig. 4.38 0.76 =
65
Diameter of cylinder, D = 200 mm = 0.2 m B.P. = 0.76 × 65 = 49.4 kW
Stroke length, L = 250 mm = 0.25 m Mean effective pressure can be calculated based on
Number of cylinders, n=2 I.P. or B.P. of the engine.
Compression ratio, r = 14 npmi LANk 10
Fuel consumption = 14 kg/h I.P. =
6
Engine speed, N = 300 r.p.m. where, pmi = Indicated mean effective pressure
Relative efficiency, relative = 65%
2 pmi 0.25 / 4 0.22 300 1 10
Mechanical efficiency, mech. = 76% 65 =
6
Cut-off = 5% of stroke
Calorific value of fuel, C = 41800 kJ/kg 65 6 4
pmi =
k = 1 ...... for two-stroke cycle engine 2 0.25 0.22 300 10
= 8.27 bar. (Ans.)
V3 and brake mean effective pressure,
Cut-off ratio, =
V2 pmb = 0.76 × 8.27 = 6.28 bar. (Ans.)
Also, V3 – V2 = 0.05Vs Example 4.6. A single cylinder 4-stroke diesel engine gave
the following results while running on full load :
= 0.05(V1 – V2)
or, V3 – V2 = 0.05 (13V2 – V2) Area of indicator card = 300 mm2
LM∵ V1 OP
r 13
Length of diagram
Spring constant
= 40 mm
= 1 bar/mm
MN V2 PQ Speed of the engine = 400 r.p.m.
or, V3 – V2 = 0.05 × 12V2 = 0.6V2 Load on the brake = 370 N
V3 Spring balance reading = 50 N
= 1.6 Diameter of brake drum = 1.2 m
V2
Fuel consumption = 2.8 kg/h
air-standard = 1 –
1 LM 1 OP Calorific value of fuel = 41800 kJ/kg
(r ) MN
1 1 PQ Diameter of the cylinder = 160 mm
Stroke of the piston = 200 mm
252 POWER PLANT ENGINEERING
(iii) Brake thermal efficiency, th(B) : Steam formed per kg of fuel in the exhaust
B.P. 37 = 1.4 kg
th (B) = = 10.2
mf C Specific heat of steam in exhaust
43890
3600 = 2.09 kJ/kg K
= 0.2975 or 29.75%. (Ans.)
—Heat supplied by the fuel per minute Specific heat of dry exhaust gases
10.2 = 1.0 kJ/kg K.
= × 43890 = 7461 kJ/min Solution. Given : N = 350 r.p.m., pmi = 3.1 bar, (W – S)
60
(i) Heat equivalent of B.P. = 640 N, mf = 1.52 kg, mw = 162 kg, tw = 30°C, tw = 55°C,
2
= B.P. × 60 = 37 × 60 = 2220 kJ/min. 1
indicated power, brake power and draw a heat balance sheet = 162 × 4.18 × (55 – 30) = 16929 kJ
Total mass of air = 32 × 1.52 = 48.64 kg
for a two stroke diesel engine run for 20 minutes at full
load : Total mass of exhaust gases
= Mass of fuel + Mass of air
r.p.m. = 350
= 1.52 + 48.64 = 50.16 kg
m.e.p. = 3.1 bar
Mass of steam formed = 1.4 × 1.52 = 2.13 kg
Net brake load = 640 N
Mass of dry exhaust gases
Fuel consumption = 1.52 kg
= 50.16 – 2.13 = 48.03 kg
Cooling water = 162 kg (iii) Heat carried away by dry exhaust gases
Water inlet temperature = 30°C = mg × cpg × (tg – tr)
Water outlet temperature = 55°C = 48.03 × 1.0 × (305 – 25) = 13448 kJ
Air used/kg of fuel = 32 kg
LM
(iv) Heat carried away by steam
Room temperature = 25°C
NM
= 2.13[hf + hfg + cps (tsup – ts)]
N
Exhaust temperature = 305°C At 1.013 bar pressure (atmospheric L
Cylinder bore = 200 mm pressure assumed) :
Cylinder stroke = 280 mm hf = 417.5 kJ/kg, hfg = 2257.9 kJ/kg
Brake diameter = 1 metre = 2.13 [417.5 + 2257.9 + 2.09 (305 – 99.6)]
Calorific value of fuel = 43900 kJ/kg = 6613 kJ/kg ..... neglecting sensible heat
of water at room temperature
DIESEL ENGINE POWER PLANT 255
Heat balance sheet (20 minute basis) 1 2.8 0.28 / 4 0.222 350 1 10
=
Item kJ Per cent 6
= 17.38 kW. (Ans.)
Heat supplied by fuel 66728 100
(ii) Brake power, B.P. :
(i) Heat equivalent of I.P. 19080 28.60
(W S ) DbN
(ii) Heat carried away by cooling water 16929 25.40 B.P. =
60 1000
(iii) Heat carried away by dry exhaust gases 13448 20.10
(iv) Heat carried away steam in exhaust gases 6613 9.90 590 1 350
=
(v) Heat unaccounted for (by difference) 10658 16.00 60 1000
Total 66728 100.00 = 10.81 kW. (Ans.)
Heat supplied per minute
+Example 4.10. During a test on a two stroke oil engine 4.3
on full load the following observations were recorded : = × 43900 = 3146 kJ/min.
60
Speed = 350 r.p.m.
(i) Heat equivalent of I.P. = 17.38 × 60
Net brake load = 590 N
= 1042.8 kJ/min.
Mean effective pressure = 2.8 bar
(ii) Heat lost to cooling water
Oil consumption = 4.3 kg/h
Jacket cooling water = 500 kg/h = mw × cpw × ( tw – tw )
2 1
= [hf + hfg + cps (tsup – ts)] – 1 × 4.18 × (25 – 0) Heat lost to jacket cooling water
= [417.5 + 2257.9 + 2.09 (400 – 25)] – 104.5 = 32% of the total heat supplied
= 3355 kJ/min. Specific heat of exhaust gases
Heat carried away by steam = 1.05 kJ/kg K
= 0.0967 × 3355 = 320.6 kJ/min. Total power generated
Heat balance sheet (minute basis) = VI = 200 × 210 = 42000 W = 42 kW
Power available at the brakes of the engine,
Item kJ Per cent
42
Heat supplied by fuel 3146 100 B.P. = = 51.22 kW
0.82
(i) Heat equivalent of I.P. 1042.8 33.15 Total heat supplied to the engine
(ii) Heat carried away by cooling water 870.8 27.70 = Fuel supplied per min.
(iii) Heat carried away by dry gases 887 28.15
× calorific value of fuel
(iv) Heat carried away by steam 320.6 10.20
11.2
(v) Heat unaccounted for (by difference) 24.8 0.80 = × 42600 = 7952 kJ/min.
60
Total 314.6 100 (i) Heat equivalent of B.P.
= 51.22 × 60 = 3073 kJ/min
Example 4.11. During a test on a Diesel engine the
following observations were made : Mass of exhaust gases formed per minute
The power developed by the engine is used for driving FG A ratio 1IJ
a D.C. generator. The output of the generator was 210 A at
200 V ; the efficiency of generator being 82%. The quantity
= Fuel supplied/min.
HF K
of fuel supplied to the engine was 11.2 kg/h ; Calorific LM A ratio means air-fuel ratioOP
value of fuel being 42600 kJ/kg. The air-fuel ratio was NF Q
18 : 1.
11.2
The exhaust gases were passed through a exhaust = (18 + 1) = 3.55 kg/min.
60
gas calorimeter for which the observations were as follows :
Water circulated through exhaust gas calorimeter = 580 (ii) Heat carried away by exhaust gases/min.
litres/h. Temperature rise of water through calorimeter = Heat gained by water in exhaust gas
= 36°C. Temperature of exhaust gases at exit from calorimeter from exhaust gases
calorimeter = 98°C. Ambient temperature = 20°C. + heat in exhaust gases at exit
Heat lost to jacket cooling water is 32% of the total from exhaust gas calorimeter
heat supplied. above room temperature
If the specific heat of exhaust gases be 1.05 kJ/kg K = mw × cpw × ( tw – tw ) + mg × cpg(tg – tr)
draw up the heat balance sheet on minute basis. 2 1
(iv) Heat carried away by dry exhaust gases/min. Take all mechanical efficiencies as 78%.
= mg × cpg × (tg – tr) Solution. Capacity of the engine = 3 litres = 0.003 m3
= 3.982 × 1.05 × (400 – 25) = 1568 kJ/min. 3500
Swept volume = × 0.003
Steam is carried away by exhaust gases. The 2
temperature of steam is also the same as that of exhaust = 5.25 m3/min.
gases e.g. 400°C. Unsupercharged induced volume
At partial pressure of steam 0.03 bar, the saturation = 5.25 × vol.
temperature is 24.1°C. Therefore, steam is superheated. = 5.25 × 0.81 = 4.25 m3
Enthalpy of steam Blower delivery pressure = 1.72 × 1.013 = 1.74 bar
= hg + cps (tsup – ts) Temperature after isentropic compression
= 2545.5 + 2.1 (400 – 24.1) = 288 × (1.72)(1.4 – 1)/1.4
= 3334.89 kJ/kg.
(v) Heat carried by steam in exhaust gases
LM T F p I OP 1
MM∵ T GH p JK PP
2 2
= 3334.89 × 0.238 = 793.7 kJ/min. = 336.3 K
(vi) Heat unaccounted for N 1 1
Q
= Total heat supplied—heat equivalent of B.P. Blower delivery temperature
– heat lost in friction FG
336.3 288 IJ
—heat carried away by cooling water
= 288 +
H
0.72 K
= 355 K
– heat carried away by dry exhaust gases LM∵ isen.
T2 T1 T T1
or T T1 2
OP
– heat carried away by steam in exhaust gases
= 8745 – (3054 + 660 + 2612.5 + 1568 + 793.7) MN T2 T1 isen. PQ
= 56.8 kJ/min. The blower delivery is 5.25 m3/min at 1.74 bar and
355 K.
Heat balance sheet on minute basis Equivalent volume at 1.013 bar and 15°C
Item kJ Per cent
5.25 1.74 288
= = 7.31 m3/min.
1.013 355
Heat supplied 8745 100
Increase in induced volume
(i)Heat equivalent of B.P. 3054 34.92 = 7.31 – 4.25 = 3.06 m3/min.
(ii)Heat lost in friction 660 7.55 Increase in indicated power from air induced
(iii)Heat carried away by cooling water 2612.5 29.87
= 13 × 3.06 = 39.78 kW
(iv) Heat carried away by dry exhaust 1568 17.93
Increase in I.P. due to the increased induction
gases
pressure
(v) Heat carried away by steam in 793.7 9.07
exhaust gases (1.74 1.013 ) 105 5.25
(vi) Heat unaccounted for 56.8 0.66 = = 6.36 kW
103 60
Total 8745 100 i.e., Total increase in I.P. = 39.78 + 6.36 = 46.14 kW
Increase in engine B.P. = mech. × 46.14
SUPERCHARGING = 0.78 × 46.14 = 35.98 kW
From this must be deducted the power required to
+Example 4.13. The average indicated power developed drive the blower
in a C.I. engine is 13 kW/m3 of free air induced per minute. Mass of air delivered by blower
The engine is a three-litre four-stroke engine running at
3500 r.p.m., and has a volumetric efficiency of 81%, referred 1.74 105 5.25
= = 0.149 kg/s
to free air conditions of 1.013 bar and 15°C. It is proposed 60 287 355
to fit a blower, driven mechanically from the engine. The Work input to blower
blower has an isentropic efficiency of 72% and works = mcp (355 – 288)
through a pressure ratio of 1.72. Assume that at the end of
= 0.149 × 1.005 × 67
induction the cylinders contain a volume of charge equal to
Power required
the swept volume, at the pressure and temperature of the
delivery from the blower. Calculate the increase in brake 0.149 1.005 67
= = 12.86 kW
power to be expected from the engine. 0.78
DIESEL ENGINE POWER PLANT 259
Bore = 10 cm = 0.62 ×
4 100 H K 2 9.81 1607.5
Stroke = 14 cm = 0.094 m3/s.
Speed = 2500 r.p.m. Va
Brake load = 480 N %vol = × 100
Vs
Barometer reading = 76 cm of Hg 0.094
Orifice diameter = 3.3 cm = × 100 = 68.6%. (Ans.)
0137
.
Coefficient of discharge of orifice (ii) The brake mean effective pressure, pmb. :
= 0.62 WN 480 2500
Pressure drop across orifice B.P. = × 10–3 kW = × 10–3
17 17
= 14 cm of Hg = 70.588 kW
Room temperature = 25°C N 1
Fuel consumption = 0.32 kg/min. = pmb LA × × 6,
60 2
Calculate the following : for six cylinder, four stroke
(i) The volumetric efficiency ; (ii) The brake mean 70.588 60 2
effective pressure (bmep) ; (iii) The engine torque ; (iv) The or, pmb =
brake specific fuel consumption (bsfc). (DU) 0.14 ( 0.1)2 2500 6
4
Solution. (i) Volumetric efficiency, vol : = 513.57 kN/m2. (Ans.)
Vs = Swept volume, (iii) Engine torque, T :
2 N B.P. = 2NT
= D L
4 60 2
× No. of cylinders, for 4-stroke.
B.P. 70.588 103
or, Torque, (T) = =
(where N = r.p.m.) 2N 2500
2
60
2500 = 269.63 Nm. (Ans.)
= (0.1)2 × 0.14 × ×6
4 60 2
(iv) Brake specific fuel consumption, bsfc :
= 0.137 m3/s.
Barometer mf (kg/h) 0.32 60
= 76 cm Hg bsfc = =
B.P. 70.588
LM 76 13.6 10
3 OP = 0.272 kg / kWh. (Ans.)
=
N100 Q
9.81 × 10–3
Example 4.15. An engine is required to develop 100 kW,
the mechanical efficiency of the engine is 86% and the engine
= 101.4 kN/m2
uses 55 kg/h of fuel. Due to improvement in the design and
p 101.3
a = = operating conditions, there is reduction in engine friction
RaT 0.287 ( 273 25 ) to the extent of 4.8 kW. If the indicated thermal efficiency
= 1.1844 kg/m3 remains the same, determine the saving in fuel in kg/h.
p = 14 cm of Hg (UPTU)
Solution. Required brake power = 100 kW
14
= × 13.6 × 103 × 9.81 100
100 Indicated power = = 116.28 kW
= 18.678 × 103 N/m2 0.86
p = a × 9.81 × ha, 55
(sfc)indicated = = 0.473 kg/kWh
116.28
where, ha = Head, m of air, causing flow
Friction power = 116.28 – 100 = 16.28 kW.
260 POWER PLANT ENGINEERING
Given that indicated thermal efficiency remains Indicated power = 100 + 11.48 = 111.48 kW
same after improvement, the (sfc)ind. also remains the same. Fuel consumption = 111.48 × 0.473 = 52.73 kg / h
After improvement : Saving in fuel = 55 – 52.73 = 2.27 kg / h
Brake power = 100 kW 2.27
Friction power = 16.28 – 4.8 = 11.48 kW or × 100 = 4.127%. (Ans.)
55
HIGHLIGHTS
1. Any type of engine or machine which derives heat energy
from the combustion of fuel or any other source and FG 2NT kWIJ
converts this energy into mechanical work is termed as a
or
H 60 1000 K
heat engine.
2. Essential components of a diesel power plant are : LM In MKS Units OP
(i) Engine
(iii) Exhaust system
(ii) Air intake system
(iv) Fuel system
MM Brake horse power, B.H.P. = (W S)(D d) N b PP
(v) Cooling system (vi) Lubrication system MM 4500
PP
(vii) Engine starting system
MN or FG 2NT IJ PQ
(viii) Governing system. H 4500 K
3. Commonly used fuel injection system in a diesel power
station : B.P. (or B.H.P.)
(iii) Mechanical efficiency, mech. =
(i) Common-rail injection system I.P. (or I.H.P.)
(ii) Individual pump injection system (iv) Thermal efficiency (indicated),
(iii) Distribution system.
I.P.
4. In liquid cooling following methods are used for circulating th. (I) =
f C
m
the water around the cylinder and cylinder head :
(i) Thermo-system cooling B.P.
and thermal efficiency (brake), th. (B) =
(ii) Forced or pump cooling f C
m
(iii) Cooling with thermostatic regulator
where mf = mass of fuel used in kg/sec.
(iv) Pressurised cooling
(v) Evaporative cooling. LM In MKS Units OP
5. Various lubrication systems use for I.C. engines are :
(i) Wet sump lubrication system MM =
I.H.P. 4500
Jm C
th. (I)
PP
(ii) Dry sump lubrication system
(iii) Mist lubrication system.
MM
f
PP
6. The following three are the commonly used starting MM =
B.H.P. 4500
Jm C
th. (B)
f
PP
systems in large and medium size engines :
(i) Starting by an auxiliary engine MN where m = Mass of fuel used in kg/min. PQ
f
MM np LANk P
ma = 0.066 Cd × d2 hw a kg/min.
THEORETICAL QUESTIONS
1. What are the advantages and disadvantages of diesel 7. Explain with the help of a neat sketch the working of a
power plants ? thermostatically controlled cooling system.
2. State the applications of diesel power plant. 8. Explain briefly the following lubrication systems :
3. What factors should be considered while selecting a site (i) Wet sump lubrication system.
for a diesel power plant ? (ii) Dry sump lubrication systems.
4. With the help of neat sketches give the construction and 9. Describe briefly the commonly used starting systems in
working of a four stroke diesel cycle engine. large and medium size engines.
10. Discuss briefly the basic designs of C.I. engine combustion.
5. List the essential components of a diesel power plant and
11. Write a short note on “Supercharging”.
explain them briefly.
12. Give the types of diesel engines used for diesel power
6. Name and explain briefly various types of fuel injection plants.
systems.
13. Give the layout of a diesel engine power plant.
UNSOLVED EXAMPLES
1. A single cylinder petrol engine working on two stroke cycle Also, calculate the brake specific fuel consumption if the
develops indicated power of 5 kW. If the mean effective air/fuel ratio is 20 : 1. Take R for air as 0.287 kJ/kg K and
pressure is 7.0 bar and the piston diameter is 100 mm, clearance volume as 0.000084 m3.
calculate the average speed of the piston. [Ans. 61.4%, 21.75 kW, 0.4396 kg/kWh]
[Hint. Average piston speed = 2LN.] [Ans. 109.1 m/s] 6. During a trial of a two stroke diesel engine the following
2. A 4-cylinder petrol engine works on a mean effective observations were recorded :
pressure of 5 bar and engine speed of 1250 r.p.m. Find Engine speed = 1500 r.p.m., load on brakes = 120 kg, length
the indicated power developed by the engine if the bore is of brake arm = 875 mm.
100 mm and stroke 150 mm. [Ans. 6.11 kW]
Determine : (i) Brake torque, (ii) Brake power.
3. A 4-cylinder four stroke S.I. engine is designed to develop [Ans. (i) 1030 Nm ; (ii) 161.8 kW]
44 kW indicated power at a speed of 3000 r.p.m. The
7. A four stroke gas engine develops 4.2 kW at 180 r.p.m.
compression ratio used is 6. The law of compression and
and at full load. Assuming the following data, calculate
expansion is pV1.3 = constant and heat addition and
the relative efficiency based on indicated power and air-
rejection takes place at constant volume. The pressure
fuel ratio used. Volumetric efficiency = 87%, mechanical
and temperature at the beginning of compression stroke
efficiency = 74%, clearance volume = 2100 cm3, sweept
are 1 bar and 50°C. The maximum pressure of the cycle is
volume = 9000 cm3, fuel consumption = 5 m3/h, calorific
limited to 30 bar. Calculate the diameter and stroke of
value of fuel = 16750 kJ/m3. [Ans. 50.2%, 7.456 : 1]
each cylinder assuming all cylinders have equal
dimensions. 8. During the trial of a four stroke cycle gas engine the
following data were recorded :
Assume diagram factor = 0.8 and ratio of stroke/bore
= 1.5. [Ans. D = 95 mm, L = 142.5 mm] Area of indicator diagram = 565.8 mm2
4. During the trial of a four stroke diesel engine, the following Length of indicator diagram = 74.8 mm
observations were recorded : Spring index = 0.9 bar/mm
Area of indicator diagram = 475 mm2, length of indicator Cylinder diameter = 220 mm
diagram = 62 mm, spring number = 1.1 bar/mm, diameter Stroke length = 430 mm
of piston = 100 mm, length of stroke = 150 mm, Number of explosions/min = 100
engine r.p.m. = 375. Determine : (i) Indicated mean effective pressure;
Determine : (i) Indicated mean effective pressure ; (ii) Indicated power.
(ii) Indicated power. [Ans. (i) 6.8 bar ; (ii) 18.5 kW]
[Ans. (i) 8.43 bar ; (ii) 3.1 kW] 9. The following observations were recorded during a trial
of a four stroke engine with rope brake dynamometer :
5. A 4-cylinder, four stroke diesel engine runs at 1000 r.p.m.
Engine speed = 650 r.p.m., diameter of brake drum
The bore and stroke of each cylinder are 100 mm and = 600 mm, diameter of rope = 50 mm, dead load on the
160 mm respectively. The cut off is 6.62% of the stroke. brake drum = 32 kg, spring balance reading = 4.75 kg.
Assuming that the initial conditions of air inside the Calculate the brake power. [Ans. 5.9 kW]
cylinder are 1 bar and 20°C, mechanical efficiency of 75%,
10. The following data refer to a four stroke petrol engine :
calculate the air-standard efficiency and brake power
Engine speed = 2000 r.p.m., ideal thermal efficiency = 35%,
developed by the engine. relative efficiency = 80%, mechanical efficiency = 85%,
volumetric efficiency = 70%.
262 POWER PLANT ENGINEERING
If the engine develops 29.42 kW brake power calculate is 0.226 kg/kWh. The air/fuel ratio as determined by
the cylinder swept volume. [Ans. 0.00185 m3] exhaust gas analysis is 25 : 1. Calculate the brake thermal
11. A single cylinder four-stroke gas engine has a bore of efficiency and volumetric efficiency of the engine.
178 mm and a stroke of 330 mm and is governed by hit Atmospheric conditions are 1.01 bar and 15°C and calorific
and miss principle. When running at 400 r.p.m. at full value for the fuel may be taken as 44200 kJ/kg.
load, indicator cards are taken which give a working loop [Ans. 36% ; 76.5%]
mean effective pressure of 6.2 bar, and a pumping loop 17. A 4-cylinder petrol engine has an output of 52 kW at
mean effective pressure of 0.35 bar. Diagrams from the 2000 r.p.m. A Morse test is carried out and the brake
dead cycle give a mean effective pressure of 0.62 bar. The torque readings are 177, 170, 168 and 174 Nm respectively.
engine was run light at the same speed (i.e. with no load), For normal running at this speed the specific fuel
and a mechanical counter recorded 47 firing strokes per consumption is 0.364 kg/kWh. The calorific value of fuel
minute. is 44200 kJ/kg.
Calculate : (i) Full load brake power,
Calculate : (i) Mechanical efficiency ;
(ii) Mechanical efficiency of the engine.
(ii) Brake thermal efficiency of the engine.
[Ans. (i) 13.54 kW ; (ii) 84.7%]
[Ans. (i) 82% ; (ii) 22.4%]
12. During a 60 minutes trial of a single cylinder four
18. A V-8 four stroke petrol engine is required to give
stroke engine the following observations were recorded :
186.5 kW at 440 r.p.m. The brake thermal efficiency can
Bore = 0.3 m, stroke = 0.45 m, fuel consumption = 11.4 kg,
be assumed to be 32% at the compression ratio of 9 : 1.
calorific value of fuel = 42000 kJ/kg, brake mean effective
The air/fuel ratio is 12 : 1 and the volumetric efficiency at
pressure = 6.0 bar, net load on brakes = 1500 N,
this speed is 69%. If the stroke to bore ratio is 0.8,
r.p.m. = 300, brake drum diameter = 1.8 m, brake rope
determine the engine displacement required and the
diameter = 20 mm, quantity of jacket cooling water =
dimensions of the bore and stroke. The calorific value of
600 kg, temperature rise of jacket water = 55°C, quantity
the fuel is 44200 kJ/kg, and the free air conditions are
of air as measured = 250 kg, exhaust gas temperature =
1.013 bar and 15°C.
420°C, cp for exhaust gases = 1 kJ/kg K, ambient
temperature = 20°C. [Ans. 5.12 litres ; 100.6 mm ; 80.5 mm]
Calculate : 19. During the trial (60 minutes) on a single cylinder oil engine
having cylinder diameter 300 mm, stroke 450 mm and
(i) Indicated power ;
working on the four stroke cycle, the following observations
(ii) Brake power ; were made :
(iii) Mechanical efficiency ; Total fuel used = 9.6 litres, calorific value of fuel =
(iv) Indicated thermal efficiency. 45000 kJ/kg, total number of revolutions = 12624, gross
Draw up a heat balance sheet on minute basis. indicated mean effective pressure = 7.24 bar, pumping
[Ans. (i) 47.7 kW; (ii) 42.9 kW; (iii) 89.9%; (iv) 35.86%] i.m.e.p. = 0.34 bar, net load on the brake = 3150 N,
13. A quality governed four-stroke, single cylinder gas engine diameter of brake wheel drum = 1.78 m, diameter of the
has a bore of 146 mm and a stroke of 280 mm. At rope = 40 mm, cooling water circulated = 545 litres, cooling
475 r.p.m. and full load the net load on the friction brake water temperature rise = 25°C, specific gravity of oil = 0.8.
is 433 N, and the torque arm is 0.45 m. The indicator Determine : (i) Indicated power,
diagram gives a net area of 578 mm 2 and a length of (ii) Brake power,
70 mm with a spring rating of 0.815 bar/mm.
(iii) Mechanical efficiency.
Calculate :
Draw up the heat balance sheet on minute basis.
(i) The indicated power (ii) Brake power [Ans. (i) 77 kW ; (ii) 61.77 kW ; (iii) 80.22%]
(iii) Mechanical efficiency. 20. The following results were obtained on full load during a
[Ans. (i) 12.5 kW; (ii) 9.69 kW; (iii) 77.5%] trial on a two stroke oil engine :
14. A two-cylinder four stroke gas engine has a bore of Engine speed = 350 r.p.m.
380 mm and a stroke of 585 mm. At 240 r.p.m. the torque
Net brake load = 600 N
developed is 5.16 kNm.
Calculate : m.e.p. = 2.75 bar
(i) Brake power Oil consumption = 4.25 kg/h
(ii) Mean piston speed in m/s Temperature rise of jacket cooling water
(iii) Brake mean effective pressure. = 25°C
[Ans. (i) 129.8 kW; (ii) 4.68 m/s; (iii) 4.89 bar] Air used per kg of oil = 31.5 kg
15. The engine of Problem 14 is supplied with a mixture of Temperature of air in test room = 20°C
coal gas and air in the proportion of 1 to 7 by volume. The Temperature of exhaust gases = 390°C
estimated volumetric efficiency is 85% and the calorific Following data also apply to the above test :
value of the coal gas is 16800 kJ/m3. Calculate the brake
Cylinder diameter = 220 mm
thermal efficiency of the engine. [Ans. 27.4%]
16. A 4-cylinder, four-stroke diesel engine has a bore of Stroke = 280 mm
212 mm and a stroke of 292 mm. At full load at 720 r.p.m., Effective brake diameter = 1 metre
the b.m.e.p. is 5.93 bar and the specific fuel consumption Calorific value of oil = 45000 kJ/kg
DIESEL ENGINE POWER PLANT 263
Proportion of hydrogen in fuel oil 21. A 4-cylinder, four-stroke diesel engine develops 83.5 kW
= 15% at 1800 r.p.m. with specific fuel consumption of
Partial pressure of steam in exhaust gases 0.231 kg/kWh, and air/fuel ratio of 23 : 1. The analysis of
= 0.04 bar fuel is 87% carbon and 13% hydrogen, and the calorific
value of the fuel is 43500 kJ/kg. The jacket cooling water
Mean specific heat of exhaust gases = 1.0 kJ/kg K flows at 0.246 kg/s and its temperature rise is 50 K. The
Specific heat of superheated steam = 2.1 kJ/kg K exhaust temperature is 316°C. Draw up an energy balance
Specific heat of water = 4.186 kJ/kg K for the engine. Take R = 0.302 kJ/kg K and cp = 1.09 kJ/kg K
Determine : (i) Indicated power, for the dry exhaust gases and cp = 1.86 kJ/kg K for
(ii) Brake power, (iii) Mechanical efficiency. superheated steam. The temperature in the test house is
17.8°C, and the exhaust gas pressure is 1.013 bar.
Draw up heat balance sheet for the test.
[Ans. B.P. = 35.8%, cooling water = 22.1%, exhaust
[Ans. (i) 17.1 kW ; (ii) 11 kW ; (iii) 64.33%]
= 24%, radiation and unaccounted = 16.7%]
5.1. GAS TURBINES—GENERAL ASPECTS and marine fields because it is self contained, light weight
not requiring cooling water and generally fit into the overall
Probably a windmill was the first turbine to produce useful shape of the structure. It is selected for ‘power generation’
work, wherein there is no pre-compression and no because of its simplicity, lack of cooling water, needs quick
combustion. The characteristic features of a gas turbine as installation and quick starting. It is used in oil and gas
we think of the name today include a compression process industry because of cheaper supply of fuel and low
and a heat-addition (or combustion) process. The gas installation cost.
turbine represents perhaps the most satisfactory way of
The gas turbines have the following “limitations” :
producing very large quantities of power in a self-contained
and compact unit. The gas turbine may have an ample 1. They are not self starting.
future use in conjunction with the oil engine. For smaller 2. Low efficiencies at part loads.
gas turbine units, the inefficiencies in compression and 3. Non-reversibility.
expansion processes become greater and to improve the 4. Higher rotor speeds.
thermal efficiency it is necessary to use a heat exchanger.
In order that a small gas turbine may compete for economy 5. Low overall plant efficiency.
with the small oil engine or petrol engine it is necessary In the last two decides, rapid progress has been
that a compact effective heat exchanger be used in the gas observed in the development and improvement of the gas
turbine cycle. The thermal efficiency of the gas turbine turbine plants for electric power production. The major
alone is still quite modest 20 to 30% compared with that of progress has been observed in the following directions :
a modern steam plant 38 to 40%. It is possible to construct (i) Increase in unit capacities of gas turbine units.
combined plants whose efficiencies are of order of 45% or (ii) Increase in their efficiency.
more. Higher efficiencies might be attained in future.
(iii) Drop in capital cost.
The following are the major fields of application of
gas turbines :
5.2. APPLICATIONS OF GAS TURBINE
1. Aviation
2. Power generation
PLANTS
3. Oil and gas industry Gas turbine plants for the purpose of power plant
4. Marine propulsion. engineering, find the following applications :
The efficiency of a gas turbine is not the criteria for 1. To drive generators and supply peak loads in
the choice of this plant. A gas turbine is used in aviation steam, diesel or hydroplants.
265
266 POWER PLANT ENGINEERING
2. To work as combination plants with conventional 3. Special cooling methods are required for cooling
steam boilers. the turbine blades.
3. To supply mechanical drive for auxiliaries. 4. Short life.
— These plants are well suited for peak load service B. Advantages Over Steam Power Plant:
since the fuel costs are somewhat higher and
1. No ash handling problem.
initial cost low. Moreover, peak load operation
permits use of water injection which increases 2. Low capital cost.
turbine work by about 40% with an increase in 3. The gas turbine plants can be installed at
heat rate of about 20%. The short duration of selected load centre as space requirement is
increase in heat rate does not prove of any much considerably less where steam plant cannot be
harm. accommodated.
— The combination arrangement of gas turbines 4. Fewer auxiliaries required/used.
with conventional boilers may be supercharging 5. Gas turbines can be built relatively quicker.
or for heat recovery from exhaust gases. In the They require much less space and civil
supercharging system air is supplied to the boiler engineering works and water supply.
under pressure by a compressor mounted on the 6. The gas turbine plant as peak load plant is more
common shaft with turbine and gases formed as preferable as it can be brought on load quickly
result of combination after coming out of the and surely.
boiler pass through the gas turbine before 7. The components and circuits of a gas turbine
passing through the economiser and the plant can be arranged to give the most economic
chimney. results in any given circumstances which is not
— The application of the gas turbine to drive the possible in case of steam power plants.
auxiliaries is not strictly included under direct 8. For the same pressure and initial temperature
electric power generation by the turbines and conditions the ratio of exhaust to inlet volume
would not be discussed. would be only 3.95 in case of gas turbine plant
as against 250 for steam plant.
5.3. ADVANTAGES AND DISADVANTAGES 9. Above 550°C, the thermal efficiency of the gas
OF GAS TURBINE POWER PLANTS turbine plant increases three times as fast the
OVER DIESEL AND THERMAL POWER steam cycle efficiency for a given top temperature
PLANTS increase.
10. The site of the steam power plant is dictated by
A. Advantages over Diesel Plants : the availability of large cooling water whereas
1. The work developed per kg of air is large an open cycle gas turbine plant can be located
compared with diesel plant. near the load centre as no cooling water is
2. Less vibrations due to perfect balancing. required. The cooling water required for closed
3. Less space requirements. cycle gas turbine is hardly 10% of the steam
4. Capital cost considerably less. power plant.
5. Higher mechanical efficiency. 11. The gas turbine plants can work quite
6. The running speed of the turbine (40,000 to economically for short running hours.
100,000 r.p.m.) is considerably large compared 12. Storage of fuel is much smaller and handling is
to diesel engine (1000 to 2000 r.p.m.). easy.
7. Lower installation and maintenance costs.
8. The torque characteristics of turbine plants are 5.4. SITE SELEC TION
far better than diesel plants.
While selectinig the site for a gas turbine plant. The
9. The ignition and lubrication systems are simpler.
following points should be given due consideration :
10. The specific fuel consumption does not increase
with time in gas turbine plant as rapidly as in 1. The plant should be located near the load centre
diesel plants. to avoid transmission costs and losses.
11. Poor quality fuels can be used. 2. The site should be away from business centres
due to noisy operations.
Disadvantages :
3. Cheap and good quality fuel should be easily
1. Poor part load efficiency. available.
2. Special metals and alloys are required for 4. Availability of labour.
different components of the plants.
GAS TURBINE POWER PLANTS 267
5. Availability of means of transportation. Refer to Fig. 5.1. A simple gas turbine plant consists
6. The land should be available at a cheap price. of the following :
7. The bearing capacity of the land should be high. 1. Turbine.
2. A compressor mounted on the same shaft or
coupled to the turbine.
5.5. THE SIMPLE GAS TURBINE PLANT
3. The combustor.
A gas turbine plant may be defined as one “in which the 4. Auxiliaries such as starting device, auxiliary
principal prime mover is of the turbine type and the working lubrication pump, fuel system, oil system and the duct
medium is a permanent gas”. system etc.
Fuel
Coupling
Compre- Generator
Turbine
ssor
Exhaust
Air inlet
A modified plant may have in addition to above an — In turbine smallest part of entering energy goes
intercooler, a regenerator, a reheater etc. to useful output, largest part leaves in exhaust.
The working fluid is compressed in a compressor Combustor
which is generally rotary, multistage type. Heat energy is
added to the compressed fluid in the chamber. This high Fuel in
energy fluid, at high temperature and presssure, then
expands in the turbine unit thereby generating power. Part Power
Compressed gas
of the power generated is consumed in driving the air
generating compressor and accessories and the rest is Output
utilised in electrical energy. The gas turbines work on open
cycle, semi-closed cycle or closed cycle. In order to improve Compressor Turbine
efficiency, compression and expansion of working fluid is
carried out in multistages.
Air in Exhaust
5.6. ENERGY CYCLE FOR A SIMPLE-CYCLE
Fig. 5.2. Energy flow diagram for gas-turbine unit.
GAS TURBINE
Shaft energy to drive compressor is about twice as
Fig. 5.2 shows an energy-flow diagram for a simple-cycle much as the useful shaft output.
gas turbine, the description of which is as follows : Actually the shaft energy keeps circulating in the
— The air brings in minute amount of energy cycle as long as the turbine runs. The important comparison
(measured above 0°C). is the size of the output with the fuel input. For the simple-
— Compressor adds considerable amount of energy. cycle gas turbine the output may run about 20 per cent of
— Fuel carries major input to cycle. the fuel input for pressure and temperature conditions at
— Sum of fuel and compressed-air energy leaves turbine inlet. This means 80% of the fuel energy is wasted.
combustor to enter turbine. While the 20% thermal efficiency is not too bad, it can be
improved by including additional heat recovery apparatus.
268 POWER PLANT ENGINEERING
7. In the gas turbine the ignition and lubrication chamber) and centrifugal force the life of the
systems are much simpler as compared with I.C. combustion chamber and blades is short/small.
engines.
(ii) Merits over steam turbines :
8. Cheaper fuels such as paraffine type, residue oils
The gas turbine entails the following advantages
or powdered coal can be used whereas special
over steam turbines :
grade fuels are employed in petrol engine to
check knocking or pinking. 1. Capital and running cost less.
9. The exhaust from gas turbine is less polluting 2. For the same output the space required is far
comparatively since excess air is used for less.
combustion. 3. Starting is more easy and quick.
10. Because of low specific weight the gas turbines 4. Weight per H.P. is far less.
are particularly suitable for use in aircrafts. 5. Can be installed anywhere.
Demerits of gas turbines : 6. Control of gas turbine is much easier.
1. The thermal efficiency of a simple turbine cycle 7. Boiler along with accessories not required.
is low (15 to 20%) as compared with I.C. engines
(25 to 30%). 5.11. CONSTANT PRESSURE
2. With wide operating speeds the fuel control is COMBUSTION GAS TURBINES
comparatively difficult.
3. Due to higher operating speeds of the turbine, it 5.11.1. Open Cycle Gas Turbines
is imperative to have a speed reduction device. Refer to Fig. 5.3. The fundamental gas turbine unit is one
4. It is difficult to start a gas turbine as compared operating on the open cycle in which a rotary compressor
to an I.C. engine. and a turbine are mounted on a common shaft. Air is drawn
5. The gas turbine blades need a special cooling into the compressor and after compression passes to a
system. combustion chamber. Energy is supplied in the combustion
chamber by spraying fuel into the air stream, and the
Fuel (Heat)
resulting hot gases expand through the turbine to the
atmosphere. In order to achieve net work output from the
2¢ Combustion 3 unit, the turbine must develop more gross work output than
chamber is required to drive the compressor and to overcome
Compressor (C.C.) Turbine Work mechanical losses in the drive. The products of combustion
(C) (T) coming out from the turbine are exhausted to the
Shaft
atmosphere as they cannot be used any more. The working
fluids (air and fuel) must be replaced continuously as they
are exhausted into the atmosphere.
If pressure loss in the combustion chamber is
1 neglected, this cycle may be drawn on a T-s diagram as
Air in 4¢
Exhaust shown in Fig. 5.4.
Line 1-2 represents : irreversible adiabatic compres-
Fig. 5.3. Open cycle gas turbine. sion.
6. One of the main demerits of a gas turbine is its Line 2-3 represents : constant pressure heat supply
very poor thermal efficiency at part loads, as the in the combustion chamber.
quantity of air remains same irrespective of load, Line 3-4 represents : irreversible adiabatic expan-
and output is reduced by reducing the quantity sion.
of fuel supplied.
Line 1-2 represents : ideal isentropic compression.
7. Owing to the use of nikel-chromium alloy, the
manufacture of the blades is difficult and costly. Line 3-4 represents : ideal isentropic expansion.
8. For the same output the gas turbine produces Assuming change in kinetic energy between the
five times exhaust gases than I.C. engine. various points in the cycle to be negligibly small compared
9. Because of prevalence of high temperature with enthalpy changes and then applying the flow equation
(1000 K for blades and 2500 K for combustion to each part of cycle, for unit mass, we have
270 POWER PLANT ENGINEERING
Work input (compressor) = cp (T2 – T1) of cp and for the expansion process, and fixed mean values
Heat supplied (combustion chamber) = cp (T3 – T2) of cp and for the compression process. In an open cycle
Work output (turbine) = cp (T3 – T4) gas turbine unit the mass flow of gases in turbine is greater
than that in compressor due to mass of fuel burned, but it
T is possible to neglect mass of fuel, since the air/fuel ratios
used are large. Also, in many cases, air is bled from the
compressor for cooling purposes, or in the case of air craft
at high altitudes, bled air is used for de-icing and cabin
p2 air-conditioning. This amount of air bled is approximately
the same as the mass of fuel injected therein.
3
5.11.2. Methods for Improvement of Thermal Efficiency
of Open Cycle Gas Turbine Plant
The following methods are employed to increase the specific
p1 output and thermal efficiency of the plant :
2¢
2 1. Intercooling 2. Reheating
4¢ 3. Regeneration.
4
1. Intercooling. A compressor in a gas turbine cycle
utilises the major percentage of power developed by the
1 gas turbine. The work required by the compressor can be
s reduced by compressing the air in two stages and
incorporating an intercooler between the two as shown in
Fig. 5.4 Fig. 5.5. The corresponding T-s diagram for the unit is
shown in Fig. 5.6 (a). The actual processes take place as
Net work output
follows :
= Work output – work input
= cp (T3 – T4) – cp(T2 – T1) Intercooler Fuel (Heat)
Net work output
and thermal
Heat supplied C.C.
c p (T3 T4 ) c p (T2 T1 ) 3 5
= 2¢ 4¢
c p (T3 T2 )
Compressor isentropic efficiency, comp.
Work input required in isentropic compression L.P. H.P. T Work
= C C
Actual work required
c p (T2 T1 ) T2 T1
= ...(5.1)
c p (T2 T1 ) T2 T1
Turbine isentropic efficiency, turbine 1 6¢
Air in Exhaust
Actual work output
=
Isentropic work output
Fig. 5.5. Turbine plant with intercooler.
c p (T3 T4 )
T T4
= 3 ...(5.2) 1-2 : L.P. (Low pressure) compression
c p (T3 T4 ) T3 T4
2-3 : Intercooling
Note. With the variation in temperature, the value of 3-4 : H.P. (High pressure) compression
the specific heat of a real gas varies, and also in the open
4-5 : C.C. (Combustion chamber)–heating
cycle, the specific heat of the gases in the combustion
5-6 : T (Turbine)–expansion
chamber and in turbine is different from that in the
compressor because fuel has been added and a chemical The ideal cycle for this arrangement is 1-2-3-4-5-6 ;
change has taken place. Curves showing the variation of the compression process without intercooling is shown as
cp with temperature and air/fuel ratio can be used, and a 1-L in the actual case, and 1-L in the ideal isentropic case.
suitable mean value of cp and hence can be found out. It Now, work input (with intercooling)
is usual in gas turbine practice to assume fixed mean value = cp(T2 – T1) + cp(T4 – T3) ...(5.3)
GAS TURBINE POWER PLANTS 271
% Thermal efficiency
1
Simple
20
s
T Note. cpa and cpg stand for specific heats of air and gas
respectively at constant pressure.
40 6 Exhaust Heat
exchanger
Reheat 5¢
30
3 5¢
% Thermal efficiency
2¢ C.C.
Simple
20 4
10 C T Work
0
0 5 10 15 20
Pressure ratio 1
Air in
Fig. 5.8 (b)
Since the pressure lines diverge to the right on T-s Fig. 5.9. Gas turbine with regenerator.
diagram it can be seen that the temperature difference
Fig. 5.10 (b) shows that the regenerative cycle has
(T5 – T6) is always greater than (T4 – TL), so that reheating
higher efficiency than the simple cycle only at low pressure
increases the net work output.
ratios. At pressure ratios above a certain limit the efficiency
Although net work is increased by reheating the heat of the regenerative cycle drops since in that case the
to be supplied is also increased, and the net effect can be to regenerator will cool the compressed air entering the
reduce the thermal efficiency [Fig. 5.8 (b)] combustion chamber instead of heating it.
Heat supplied = cpg (T3 – T2) + cpg (T5 – T4).
GAS TURBINE POWER PLANTS 273
C T Work
3 5¢
2¢
5
2
6 1 4
Cooler
1
s Heat rejection
(at constant lower
pressure)
Fig. 5.10. (a) T-s diagram for the unit.
Fig. 5.11. Closed cycle gas turbine.
40
Regenerative
30
% Thermal efficiency
Simple
20
10
0
0 5 10 15 20
Pressure ratio
F I
T 1
1
T3 p
GH JK
3 Similarly 2 or T3 = T4 ( rp )
T4 p1
T4 T1
air-standard = 1 – 1 1
T4 (rp ) T1(rp )
1
=1– 1
...(5.6)
(rp )
e
ur
4
ss
on
of
c temperature of the material of the turbine at the point at
ne
s which this temperature is reached by the compression
Li process alone, no further heating of the gas in the combustion
1
chamber would be permissible and the work of expansion
would ideally just balance the work of compression so that
s no excess work would be available for external use.
We as designers are always interested in the
Fig. 5.13. T-s diagram. percentage of work developed by the turbine available for
Operation 2-3 : Heat flows into the system electric generation.
increasing the volume from V2 Wnet
to V3 and temperature from T2 Work ratio =
Wturbine
to T3 whilst the pressure Wturbine Wcomp. Wcomp.
remains constant at p2. Heat = 1
Wturbine Wturbine
received = mcp (T3 – T2).
mcp (T2 T1) T T1
Operation 3-4 : The air is expanded = 1 1 2
mcp (T3 T4 ) T3 T4
isentropically from p2 to p1, the
temperature falling from T3 to FG 1IJ
H K T F 1IJ
GH
T4. No heat flow occurs. T1 (r )
p 1 T1 K
= 1 = 1 (rp )
Operation 4-1 : Heat is rejected from the T3 T3
T3
system as the volume FG 1IJ
decreases from V4 to V1 and the (rp )
H K
temperature from T4 to T1 ...(5.7)
whilst the pressure remains The ‘work ratio’ increases with increase in turbine
constant at p1. Heat rejected = inlet temperature, decrease in compressor inlet temperature
mcp (T4 – T1). and decrease in pressure ratio of the cycle. The compressor
Work done inlet temperature is always atmospheric temperature
air-standard = particularly in open cycle plant and turbine inlet
Heat received temperature is limited by metallurgical considerations. The
Heat received cycle Heat rejected cycle highest temperature ever used for gas turbine power plants
= is about 1000 K.
Heat received cycle
From the eqn. (5.7), it is obvious that the maximum
mc p (T3 T2 ) mc p (T4 T1 ) T4 T1 possible pressure ratio for the fixed temperature T1 and T3
= 1
mc p (T3 T2 ) T3 T2 is given by:
F IJ
F T I GH
Now, from isentropic expansion
K
G J
1
3 ...(5.8)
T2 p F I
1 (rp ) max
HT K
GH JK
1
2 because, the value of rp greater than this gives the negative
T1 p1
value of work ratio which is impossible for power developing
1 system. Thus, the maximum value of rp to be used for finding
the maximum possible efficiency in eqn. (5.6) is given by
T2 = T1 ( rp ) , where rp = pressure ratio
eqn. (5.8).
GAS TURBINE POWER PLANTS 275
F T4 I – T F T 1I HT K
1 HT K
1
GH
= mcpT3 1
T3
JK GH T JK
1
2
1
...(5.9)
Thus the pressure ratio for maximum work is a
In case of a given turbine the minimum temperature function on the limiting temperature ratio.
T1 and the maximum temperature T3 are prescribed, T1 Comparing eqns. (5.8) and (5.9), we get
being the temperature of the atmosphere and T3 the
maximum temperature which the metals of turbine would rp = (rp )max ...(5.10)
withstand. Consider the specific heat at constant pressure l Fig. 5.14 shows an arrangement of closed cycle
cp to be constant. Then, stationary gas turbine plant in which air is
1 continuously circulated. This ensures that the
T3 T2
Since, (rp ) air is not polluted by the addition of combustion
T4 T1 waste product, since the heating of air is carried
1 out in the form of heat exchanger shown in the
Using the constant ‘z’ =
, diagram as air heater. The air exhausted from
We have, work output/cycle the power turbine is cooled before readmission
LM F 1 I O to L.P. compressor. The various operations as
G J T (r 1)P z indicated on T-s diagram (Fig. 5.15) are as
MN H r K
W = K T3 1
PQ p
z 1 p
follows :
Differentiating with respect to r Operation 1-2 : Air is compressed from p1 to px
p
L OP in the L.P. compressor.
= K MT
dW z ( z 1)
T zr
dr pMN r ( z 1)3
p PQ 1 p
= 0 for a maximum
Q4
Heat
exchanger
Cooler 10
5
1 External
4¢ combustion
6 (Q1)
2¢ 3
7¢
Intercooler External
combustion
(Q2) 8
Q3
L.P.
Work
T
9¢
Operation 2-3 : Air is cooled in the intercooler Operation 9-10 : Air from L.P. turbine is passed
at constant pressure px. to the heat exchanger where
Operation 3-4 : Air is compressed in the H.P. energy is transferred to the air
compressor from px to p2. delivered from the H.P.
Operation 4-5 : High pressure air is heated at compressor. The temperature
constant pressure by exhaust of air leaving the heat
gases from power turbine in exchanger and entering the
the heat exchanger to T5. cooler is T10.
Operation 5-6 : High pressure air further Operation 10-1 : Air cooled to T1 by the cooler
heated at constant pressure to before entering the L.P.
the maximum temperature T6 compressor.
by an air heater (through The energy balance for the whole plant is as follows:
external combustion). Q1 + Q2 – Q3 – Q4 = W
Operation 6-7 : The air is expanded in the H.P. l In a closed cycle plant, in practice, the control of
turbine from p2 to px producing power output is achieved by varying the mass
work to drive the compressor. flow by the use of a reservoir in the circuit. The
Operation 7-8 : Exhaust air from the H.P. reservoir maintains the design pressure and
turbine is heated at constant temperature and therefore achieves an
pressure in the air heater approximately constant level of efficiency for
(through external combustion) varying loads.
to the maximum temperature l In this cycle, since it is closed, gases other than
T8 (= T6). air with favourable properties can be used ;
furthermore it is possible to burn solid fuels in
T
the combustion heaters.
p2
l
p
9¢
7¢ 80
5 7 9 70
60 Closed cycle
4¢ 2¢ gas turbine plant
Thermal efficiency
4 2 10 50
Steam plant
40
3
1 ü
30 ý Diesel Open cycle with
þ regeneration, intercooling
s 20 & reheating
10
Fig. 5.15. T-s diagram for the plant. 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Turbine inlet temperature (°F)
Operation 8-9 : The air is expanded in the L.P.
turbine from px to p1, producing
energy for a flow of work Fig. 5.16. Comparison of thermal efficiency between steam and
externally. closed cycle gas turbine plants.
GAS TURBINE POWER PLANTS 277
— It is obvious from the figure that the gas Demerits of closed cycle :
turbine plant should be operated above 1. Complexity
550°C to compete with the steam plants. 2. Large amount of cooling water is required. This
— Above 375°C, the gap between the steam limits its use to stationary installation or marine
cycle and gas turbine cycle efficiency use where water is available in abundance.
widens. 3. Dependent system.
— Above 550°C, the efficiency of the gas 4. The weight of the system per kW developed is
turbine plant increases 3 times as fast as high comparatively, therefore not economical for
the steam cycle efficiency for a given top moving vehicles.
temperature increase. 5. Requires the use of a very large air heater.
l The major factor responsible for inefficiency in
this cycle is the large irreversible temperature 5.12. CONSTANT VOLUME COMBUSTION
drop which occurs in the air heaters between the TURBINES
furnace and circulating gas.
Refer to Fig. 5.17. In a constant volume combustion turbine,
Note. 1. In a closed cycle gas turbines, although air has the compressed air from an air compressor C is admitted
been extensively used, the use of ‘helium’ which though of into the combustion chamber D through the valve A. When
a lower density, has been inviting the attention of
manufacturers for its use, for large output gas turbine A, B = Valves
units. The specific heat of helium at constant pressure is C = Compressor
about ‘five times’ that of air, therefore for each kg mass
flow the heat drop and hence energy dealt with in helium D = Combustion chamber
machines is nearly five times of those in case of air. The P = Fuel pump
surface area of the heat exchanger for helium can be kept S = Spark plug
as low as 1/3 of that required for gas turbine plant using T = Turbine
air as working medium. For the same temperature ratio
and for the plants of the same output the cross-sectional
area required for helium is much less than that for air. It
D
may therefore be concluded that the size of helium unit is A
considerably small comparatively.
SB P
2. Some gas turbine plants work on a combination of two
cycles the open cycle and the closed cycle. Such a
combination is called the semi-closed cycle. Here a part
of the working fluid is confined within the plant and
another part flows from and to atmosphere.
C T Work
5.11.4. Merits and Demerits of Closed Cycle Turbine
Over Open Cycle Turbine
Merits of closed cycle :
1. Higher thermal efficiency Air in Exhaust
2. Reduced size (From atmosphere) (To atmosphere)
3. No contamination
Fig. 5.17. Constant volume combustion gas turbine.
4. Improved heat transmission
5. Improved part load efficiency the valve A is closed, the fuel is admitted into the chamber
6. Lesser fluid friction by means of a fuel pump P. Then the mixture is ignited by
means of a spark plug S. The combustion takes place at
7. No loss of working medium
constant volume with increase of pressure. The valve B
8. Greater output
opens and the hot gases flow to the turbine T, and finally,
9. Inexpensive fuel. they are discharged into atmosphere. The energy of the
hot gases is thereby converted into mechanical energy. For
278 POWER PLANT ENGINEERING
continuous running of the turbine these operations are pulverising plant for coal in gas turbine applications is
repeated. much lighter and smaller than its counterpart in steam
The main demerit associated with this type of generators. Introduction of fuel in the combustion chamber
turbine is that the pressure difference and velocities of hot of a gas turbine is required to be done against a high
gases are not constant ; so the turbine speed fluctuates. pressure whereas the pressure in the furnace of a steam plant
is atmospheric. Furthermore, the degree of completeness of
5.13. GAS TURBINE FUELS combustion in gas turbine applications has to be very high
as otherwise soot and dust in gas would deposit on the
The various fuels used in gas turbines are enumerated and
turbine blading.
discussed as follows :
Some practical applications of solid fuel burning in
1. Gaseous fuels
turbine combustors have been commercially made available
2. Liquid fuels in recent years. In one such design finely crushed coal is
3. Solid fuels. used instead of pulverised fuel. This fuel is carried in steam
1. Gaseous fuels. Natural gas is the ideal fuel for of air tangentially into one end of a cylindrical furnace while
gas turbines, but this is not available everywhere. gas comes out at the centre of opposite end. As the fuel
Blast furnace gas and producer gas may also be used particles roll around the circumference of the furnace they
for gas turbine power plants. are burnt and a high temperature of about 1650°C is
maintained which causes the mineral matter of fuel to be
2. Liquid fuels. Liquid fuels of petroleum origin
converted into a liquid slag. The slag covers the walls of
such as distillate oils or residual oils are most commonly
the furnace and runs out through a top hole in the bottom.
used for gas turbine plant. The essential qualities of these
The result is that fly ash is reduced to a very small content
fuels include proper volatility, viscosity and calorific value.
in the gases. In another design a regenerator is used to
At the same time it should be free from any contents of
transfer the heat to air, the combustion chamber being
moisture and suspended impurities that would clog the
located on the outlet of the turbine, and the combustion is
small passages of the nozzles and damage valves and
carried out in the turbine exhaust stream. The advantage
plungers of the fuel pumps.
is that only clean air is handled by the turbine.
Minerals like sodium, vanadium and calcium prove
very harmful for the turbine blading as these build deposits 5.14. EFFECT OF OPERATING VARIABLES
or corrode the blades. The sodium in ash should be less
ON THERMAL EFFICIENCY
than 30% of the vanadium content as otherwise the ratio
tends to be critical. The actual sodium content may be The thermal efficiency of actual open cycle depends on
between 5 ppm to 10 ppm (part per million). If the the following thermodynamic variables :
vanadium is over 2 ppm, the magnesium in ash tends to (i) Pressure ratio
become critical. It is necessary that the magnesium in ash
is least three times the quantity of vanadium. The content (ii) Turbine inlet temperature (T3)
of calcium and lead should not be over 10 ppm and 5 ppm (iii) Compressor inlet temperature (T1)
respectively.
(iv) Efficiency of the turbine (turbine)
Sodium is removed from residual oils by mixing with
5% of water and then double centrifuging when sodium (v) Efficiency of the compressor (comp).
leaves with water. Magnesium is added to the washed oil 1. Effect of turbine inlet temperature and
in the form of epsom salts, before the oil is sent into the pressure ratio :
combustor. This checks the corrosive action of vanadium.
Residual oils burn with less ease than distillate oils and If the permissible turbine inlet-temperature (with
the latter are often used to start the unit from cold, after the other variables being constant) of an open cycle gas
which the residual oils are fed in the combustor. In cold turbine power plant is increased its thermal efficiency is
conditions residual oils need to be preheated. amply improved. A practical limitation to increasing the
turbine inlet temperature, however, is the ability of the
3. Solid fuels. The use of solid fuels such as coal in
pulverised form in gas turbines present several difficulties material available for the turbine blading to withstand the
most of which have been only partially overcome yet. The high rotative and thermal stresses.
GAS TURBINE POWER PLANTS 279
e
— Refer to Fig. 5.18. For a given turbine inlet
or
ss
temperature, as the pressure rate increases, the 36 90
re
mp
heat supplied as well as the heat rejected are
32
co
reduced. But the rate of change of heat supplied
d
% Thermal efficiency
an
is not the same as the rate of change heat rejected. 28 85
ne
As a consequence, there exists an optimum
i
urb
pressure ratio producing maximum thermal 24
efficiency for a given turbine inlet temperature. %T 80
20
— As the pressure ratio increases, the thermal
efficiency also increases until it becomes 16
maximum and then it drops off with a further
75
increase in pressure ratio (Fig. 5.19). Further, 12
8
hcomp. = hturbine = 0.80
4
28 t1 = 15.5°C 70
t3 = 1095°C 0
1 2 3 4 5 6 7 8 9 10
24 980°C Pressure ratio
760°C
16 actual gas turbine cycle is very sensitive to variations in
the efficiencies of the compressor and turbine. There is a
12 650°C particular pressure ratio at which maximum efficiencies
occur. For lower efficiencies, the peak of thermal efficiency
8 occur at lower pressure ratios and vice versa.
3. Effect of compressor inlet temperature :
4 Refer to Fig. 5.21. With the decrease in the compres-
540°C sor inlet temperature there is increase in the thermal effi-
0 ciency of the plant. Also, the peaks of thermal efficiency
1 2 3 4 5 6 7 8 9 10
occurs at high pressure ratios and the curves become flat-
Pressure ratio ter giving thermal efficiency over a wider pressure ratio
Fig. 5.19. Effect of pressure ratio and turbine inlet range.
temperature.
280 POWER PLANT ENGINEERING
To boiler
Feed water Fig. 5.23. Arrangement of supercharged boiler.
To chimney
Steam
Load
turbine
Boiler
and
Superheater
Economiser
Bled
steam Condenser
Gas Compressor
Load turbine
Combustor
Fig. 5.24. Use of exhaust gases for combustion in the furnance of the steam plant.
50
Steam plant
40
30
Conventional steam
plant 20
10
93 204 315 426 537 648 759 810 981 1092 1203
Temperature (°C)
Combination plant
Fig. 5.26. Comparison between steam and closed cycle gas
turbine plant.
Plant heat rate
0 20 40 60 80 100 1. Turbo-charging :
% of rated capacity Refer to Fig. 5.27. This method is known as
Fig. 5.25
282 POWER PLANT ENGINEERING
After
Diesel engine Power cooler
output
After
cooler
Power
output
Diesel engine
C T
the fuel. The fuel flow is controlled to obtain the necessary — Whereas the major portion of the total space is
warm up. occupied by the intercoolers, combustion
3. Adjust the speed and voltage and synchronise the chambers, heat exchangers, waste heat boilers
alternator. and interconnecting duct work, the rotating
4. Build up the load on the alternator by governor parts of the plant form a very small part of the
gear control. total volume of the plant.
2. Shut down of a gas turbine :
Shut down of a gas turbine occurs very quickly after 5.18. COMPONENTS OF A GAS TURBINE
the fuel is cut off from the combustor. A rapid shut down is POWER PLANT
desirable since it minimizes the chilling effect resulting
from passing cold air through the hot turbine. Turning The main components of a gas turbine power plant are
gears are usually employed, or alternatively the starting enumerated and discussed as follows :
device may be operated at reduced speed to ensure 1. Gas turbines
symmetrical cooling of rotor. This avoids thermal ‘kinking’ 2. Compressors
of the shaft. 3. Combustor
4. Intercoolers and regenerators.
5.17. GAS TURBINE POWER PLANT LAYOUT
1. Gas turbines :
The layout of a gas turbine plant exercises a very important
A turbine basically employs vanes or blades
effect on the overall performance of the plant, as it is
mounted on a shaft and enclosed in a casing. The flow of
possible to incur a loss to the extent of 20% of the power
fluid through the turbine in most design is axial and
developed in the interconnecting ducts having a
tangential to the rotor at a nearly constant or increasing
considerable number of sharp bends. Therefore, ample care
radius. The basic requirements of the turbines are : (i) Light
should be taken in the design and layout of the air as well
weight, (ii) High efficiency, (iii) Reliability in operation, and
as gas circuits. Fig. 5.30 shows a schematic simplified
(iv) Long working life. Large work output can be obtained
diagram of a gas turbine power plant layout. The following
per stage with high blade speeds when the blades are
points are worth noting :
designed to sustain higher stresses. More stages of the
— In this case the main building is the turbine turbine are always preferred in gas turbine power plant
house in which major portion of the plant as well because it helps to reduce the stresses in the blades and
as auxiliaries are installed. Usually it is similar increases the overall life of the turbine.
to the steam plant house in many respects.
It is essential to cool the gas turbine blades for long
— The storage tanks containing fuel oil are
life as these are continuously subjected to high temperature
arranged outside but adjoining the turbine
gases. The blades can be cooled by different methods, the
house. In some installations even heat
common method being the air-cooling. The air is passed
exchangers are also out of the doors.
through the holes provided through the blade.
The following accessories are fitted to the turbine :
Air
7 (i) Tachometer. It shows the speed of the machine
1 2 and also actuates the fuel regulator in case the speed shoots
filters
above or falls below the regulated speed, so that the fuel
regulator admits less or more fuel into the combustor and
varies the turbine power according to the demand. The
tachometer is driven through a gear box.
(ii) An overspeed governor. The governor backs off
fuel feed if exhaust temperature from the turbine exceeds
3 6 the safe limit, thermal switches at the turbine exhaust
4 5 acting on fuel control to maintain present maximum
temperature.
(iii) Lubricating oil pump. It supplies oil to the
1 = L.P. Compressor 2 = L.P. Turbine bearings under pressure.
3 = Starting motor 4 = Alternator (iv) Starting motor or engine
5 = H.P. Compressor 6 = Combustion chamber (v) Starting set-up gear
7 = Heat exchangers (vi) Oil coolers
(vii) Filters
Fig. 5.30. Gas turbine power plant layout. (viii) Inlet and exhaust mufflers.
284 POWER PLANT ENGINEERING
Impellers
(iv) Through mixing of fuel and air. type intercooler (Fig. 5.34) is generally preferred for
(v) Carbon deposits must not be formed under any effective heat transfer.
conditions.
Water in Water out
The physical process of combustion may be divided
into four important steps : Dividing
1. Formation of reactive mixture plate
2. Ignition
3. Flame propagation.
4. Cooling of combustion products with air. Atomi-
sation should be done for perfect burning.
Fig. 5.33 shows an arrangement of a typical
combustor design which employs an outer cylindrical shell Air Air
out in
with a conical inner sleeve which is provided with ports or
slots along the length. At the cone apex is fitted a nozzle
through which fuel is sprayed in a conical pattern into the
sleeve and near this is an igniting device or spark plug. A
fuel line conveys the fuel to the nozzle. A few air ports
provided close to the situation of the nozzle supply the
combustion air directly to the fuel and are fitted with vanes
to produce a whirling motion of oil and thereby create Fig. 5.34. Intercooler.
turbulence. The rest of the air admitted ahead of
Regenerators. Refer to Fig. 5.35. In the regenera-
combustion zone serves to cool the combustor and outlet
tor heat transfer takes place between the exhaust gases
gases. The combustor is best located between the
and cool air. It is usually made in shell and tube construc-
compressor outlet and turbine inlet and takes the shape of
tion with gas flowing inside the tubes and air outside the
a cylinder. Alternatively, the ‘can’ arrangement may be
tubes, the two fluids being made to flow in opposite direc-
used in which the flow is divided to pass through a number
tions. Since the gas is bound to carry dust and deposit the
of smaller cylindrical chambers. In this latter design the
same on the heat transfer surface, the internal flow through
adjacent chambers may be interconnected through small
the tubes is convenient as the tube inside can be easily
tubes so that a simple igniting device fitted in one of the
cleaned with brushes whereas it is very difficult to clean
chambers serves all the chambers.
the outside surface of tubes. The effect of counterflow is
The nozzle sprays the fuel under pressure in an the highest average temperature difference between the
atomised conical spray. The fuel is delivered to the nozzle heating and heated medium with consequent high heat
through the fuel line and flows out through tangential slots transfer between the two fluids. A number of baffles in the
in the nozzle, thus being given a whirling motion in an air put in the shell make the air to flow in contact with
annular chamber from where it passes out through a small maximum heat transfer. However, the pressure drop in both
orifice in the conical pattern of desired angle. air and gas during the flow should be minimum possible.
Outer shell
Gas out Gas in
Nozzle
Fig. 5.36. Open cycle gas turbine with separate power turbine.
Exhaust
Inter cooler
Water Out
in H.E.
C.C.
Fuel
Reheater Fuel
Air in
Power
output
L.P.T.
Exhaust
H.E.
C.C.
Fuel
C H.P.T.
Fuel
Reheater
Air in
Power output
L.P.T.
Fig. 5.40. Series flow plant with reheat between power turbine stages.
288 POWER PLANT ENGINEERING
Exhaust
H.E. C.C.
Fuel
C.C.
Power output
C H.P.T. L.P.T.
Air in
45
50
40
45
35 650°C
40
Air rate kg/H.P. – hr
30
35
25 30
815.5°C
hcomp. = 0.85
20 25
hturbine = 0.85
t3 = 650°C
t1 = 21°C 20
15
hcomp. = 0.85, hturbine = 0.90
15
10 238 249 260 271 282 293 304
1 3 5 7 9 11 Compressor inlet temp. (°C)
Pressure ratio (p2/p1)
Fig. 5.43. Effect of the compressor inlet
Fig. 5.42. Effect of turbine inlet temperature
temperature on air rate.
and pressure ratio on air rate.
GAS TURBINE POWER PLANTS 289
50
5.21. FREE-PISTON ENGINE PLANT
Free-piston engine plants are the conventional gas turbine
45 plants with the difference that the air compressor and
t1 = 15.5°C combustion chamber are replaced by a free piston engine.
t3 = 650°C The working of such a plant is explained in Fig. 5.46.
40
Refer to Fig. 5.46. A free-piston engine unit
comprises of five cylinders with two assemblies of pistons
Air rate kg/H.P. – hr
DV1 DV2
Diesel cylinder
Air
Compressed air receiver cushion
(a) cylinder
To turbine
c los ler + R
Advantages of Free-piston Engine Arrange- Free piston
plex r coo
gas generator m n te
ment : 40 Co r + I
o
turbine unit rat
1. Less air rate as compared to a conventional gas ge
ne
e
turbine. 30 Diesel +
R
am le n cycle
2. It is possible to achieve efficiency more than yc ope
Ste p le
c
Sim
en
40 per cent. 20
Op
WORKED EXAMPLES
Fp I
1
FG 4 IJ 41800 = (90 + 1) × 1.0 × (T3 – 471)
1.4 1
T2
GH p JK
1.4
H 1K
2
= = 1.486 41800
T1 1 i.e., T3 = + 471 = 930 K
91
T2 = (20 + 273) × 1.486 = 435.4 K
Fp I
1
F 1I
0.4
G J
T4
GH p JK
0.4
T T1
H 4K
4
Again, = = 0.672
compressor = 2 T3
T2 T1 3
r
r
ba
ba
Wnet = Wturbine – Wcompressor
5
9
4.
953 3
= 290.4 – 242.2 = 48.2 kJ/kg
Power in kilowatts r
ba
= 48.2 × 16 = 771.2 kW. (Ans.) 1
2¢
2 4¢
Example 5.3. Calculate the thermal efficiency and work
ratio of the plant is example 5.2, assuming that cp for the 4
combustion process is 1.11 kJ/kg K.
293
Solution. Heat supplied = cp(T3 – T2) 1
s
= 1.11 (883 – 529)
= 392.9 kJ/kg Fig. 5.50
(i) The quantity of air circulation, ma :
Net work output 48.2
thermal = For isentropic compression 1-2,
Heat supplied 392.9
F I
1
F 5I
= 0.1226 or 12.26%. (Ans.) 1.4 1
G J
T2 p
GH JK
1.4
If the mass of air flowing is ma kg/s, the power T2 = 288 × 1.745 = 502.5 K
developed by the plant is given by T2 T1
P = ma × Wnet kW Also, compressor =
T2 T1
1065 = ma × 79.3
502.5 288
1065 0.82 =
ma = = 13.43 kg. T2 288
79.3
502.5 288
i.e., Quantity of air circulation = 13.43 kg. (Ans.) T2 = + 288 = 549.6 K
0.82
(ii) Heat supplied per kg of air circulation : Wcompressor = cpa(T2 – T1)
Actual heat supplied per kg of air circulation
= 1.005 × (549.6 – 288)
c p (T3 T2 ) 1.024 (953 494)
= 262.9 kJ/kg
combustion 0.85
= 552.9 kJ/kg.
C.C.
(iii) Thermal efficiency of the cycle, thermal : 3
2¢
Work output 79.3
thermal =
Heat supplied 552.9 H.P.
= 0.1434 or 14.34%. (Ans.) C
T
Example 5.5. Air is drawn in a gas turbine unit at 15°C
and 1.01 bar and pressure ratio is 7 : 1. The compressor is
driven by the H.P. turbine and L.P. turbine drives a separate 1 Air 4¢
power shaft. The isentropic efficiencies of compressor, and inlet
the H.P. and L.P. turbines are 0.82, 0.85 and 0.85 L.P.
respectively. If the maximum cycle temperature is 610°C, T
calculate : Generator
(i) The pressure and temperature of the gases Power
entering the power turbine. turbine 5¢
(ii) The net power developed by the unit per kg/s Exhaust
mass flow. (a)
(iii) The work ratio.
(iv) The thermal efficiency of the unit. T
Neglect the mass of fuel and assume the following : r
ba
For compression process cpa = 1.005 kJ/kg K and .0
7
7
= 1.4
3 r
For combustion and expansion processes : cpg = ba
6
1.15 kJ/kg K and = 1.333. 1 .63
Solution. Given : T1 = 15 + 273 = 288 K,
2¢ 4¢
p2 2 1b
ar
p1 = 1.01 bar, Pressure ratio = = 7, 4 1.0
p1
compressor = 0.82, turbine (H.P.) = 0.85, 5¢
5
turbine (L.P.) = 0.85,
1
Maximum cycle temperature, s
T3 = 610 + 273 = 883 K
(b)
(i) Pressure and temperature of the gases
entering the power turbine, p4 and T4 : Fig. 5.51
Considering isentropic compression 1-2, we get
Now, the work output of H.P. turbine = Work input
F I
1 to compressor
1.4 1
T2 p
GH JK
2 (7) 1.4 = 1.745 cpg(T3 – T4) = 262.9
T1 p1
GAS TURBINE POWER PLANTS 295
F I
1
0.33
T4 p
GH JK
Then, 4 (1.62) 1.33 1.27
T5 p5 3
873
T4 654.4
T5 = = 580.6 K.
1.127 1.127
Again, for L.P. turbine
T4 T5 673
4¢
turbine = 626 5
T4 T5
2¢ 4
654.4 T5 459
i.e., 0.85 = 2
654.4 580.6
T5 = 654.4 – 0.85 (654.4 – 580.6)
= 591.7 K 288
1
WL.P. turbine = cpg (T4 – T5) = 1.15 (654.4 – 591.7)
= 72.1 kJ/kg s
Hence net power output (per kg/s mass flow)
Fig. 5.52
= 72.1 kW. (Ans.)
296 POWER PLANT ENGINEERING
Considering the isentropic compression 1-2, we get Heat supplied by fuel per kg
= cp(T3 – T5) = 1.0045(873 – 626)
F I
1
1.4 1
T2 p
GH JK
2 (4) 1.4 = 1.486 = 248.1 kJ/kg
T1 p1
Net work done
T2 = 288 × 1.486 = 428 K cycle =
Heat supplied by the fuel
T2 T1
Now, compressor = 29.2
T2 T1 = = 0.117 or 11.7%. (Ans.)
248.1
428 288 Example 5.7. A gas turbine employs a heat exchanger with
i.e., 0.82 =
T2 288 a thermal ratio of 72%. The turbine operates between the
pressures of 1.01 bar and 4.04 bar and ambient temperature
428 288
T2 = + 288 = 459 K is 20°C. Isentropic efficiencies of compressor and turbine
0.82 are 80 and 85% respectively. The pressure drop on each
Considering the isentropic expansion process 3-4, side of the heat exchanger is 0.05 bar and in the combustion
we have chamber 0.14 bar. Assume combustion efficiency to be unity
and calorific value of the fuel to be 41800 kJ/kg calculate
F I
1
1.4 1
T3 p the increase in efficiency due to heat exchanger over that
GH JK
3 (4) 1.4 = 1.486
T4 p4 for simple cycle.
Assume cp is constant throughout and is equal to
T3 873
T4 = = 587.5 K. 1.024 kJ/kg K, and assume = 1.4.
1.486 1.486
For simple cycle the air-fuel ratio is 90 : 1, and for
T3 T4 873 T4 the heat exchange cycle the turbine entry temperature is the
Again, turbine =
T3 T4 873 587.5 same as for a simple cycle.
G J
T2 p
GH JK
1.4
T4 = 873 – 0.7(873 – 587.5) = 673 K T1
2
p1 H 1K 1.486
Wcompressor = cp(T2 – T1)
T2 = 293 × 1.486 = 435.4
1.4
But cp = R × = 0.287 × 1.4 1 T2 T1
1
Also, compressor =
T2 T1
= 1.0045 kJ/kg K
Wcompressor = 1.0045(459 – 288) = 171.7 kJ/kg 435.4 293
0.8 =
Wturbine = cp(T3 – T4) = 1.0045(873 – 673) T2 293
= 200.9 kJ/kg
435.4 293
Net work = Wturbine – Wcompressor T2 = + 293 = 471 K
0.8
= 200.9 – 171.7 = 29.2 kJ/kg.
Now, mf × C = (ma + mf) × cp × (T3 – T2)
Effectiveness for heat exchanger,
[ma = mass of air, mf = mass of fuel]
T5 T2
= mf C
T4 T2 T3 = + T2
c p (ma mf )
T5 459
i.e., 0.78 =
673 459 1 41800
= + 471 = 919.5 K
T5 = (673 – 459) × 0.78 + 459 = 626 K 1.024 (90 1)
GAS TURBINE POWER PLANTS 297
Heat
Exhaust exchanger
ba r
3 . ba
r
04 C.C. Fuel
9
4.
2¢
3
3
r
ba
01
1. C T Work
2¢ 4¢
2
4
293 1 4¢
1 Air in
s
(a)
Fig. 5.53
F I
1
T(K)
T4 p
GH JK
Also, 4
T3 p3
5b r
a
4b
ar
Fp I
1
4.0
=T ×G J
3.8
4
or T4 3
Hp K 3
3
r
F 1.01IJ
1.4 1 ba r
= 919.5 × G
1.4 6 a
H 3.9 K
0
= 625 K 1. 1 b
. 0
4¢ 1
T3 T4 2¢ 5
Again, turbine = 2
T3 T4
4
919.5 T4
0.85 =
919.5 625 293
1
T4 = 919.5 – 0.85(919.5 – 625) s
= 669 K (b)
(T3 T4 ) (T2 T1)
thermal = Fig. 5.54
(T3 T2 )
F I
1
F 1.06 IJ
1.4 1
G
T4 p
GH JK
(919.5 669) (471 293) 1.4
=
(919.5 471)
T3
4
p3 H 3.85 K 0.69
The H.P. turbine is required to drive both Net work output 115.15
compressors and to overcome mechanical friction. thermal =
Heat supplied 490.2
2 135.6 = 0.235 or 23.5%. (Ans.)
i.e., Work output of H.P. turbine =
0.95 (ii) Work ratio :
= 285.5 kJ/kg
Gross work of the plant
cpg (T6 – T7) = 285.5
= Wturbine (H.P.) + Wturbine (L.P.)
i.e., 1.15 (898 – T7) = 285.5
285.5 115.15
T7 = 898 – = 650 K = 285.5 + = 406.7 kJ/kg
1.15 0.95
T6 T7 Work ratio
Now, turbine (H.P.) = ;
T6 T7 Net work output 115.15
= =
898 650 Gross work output 406.7
0.85 =
898 T7 = 0.283. (Ans.)
F 898 650 IJ
= 898 – G
:
(iii) Mass flow, m
T7
H 0.85 K Let the mass flow be m , then
= 606 K m × 115.15 = 4500
F I
1
T6 p
GH JK
4500
Also, 6
m = 39.08 kg/s
T7 p7 115.15
FT I
FG IJ i.e., Mass flow = 39.08 kg/s. (Ans.)
1.333
p6 898
G J
1 0.333
H K
6
or
p7 HT K
7
606
4.82 Example 5.9. In a closed cycle gas turbine there is two-
stage compressor and a two-stage turbine. All the
p8 9
Then, = 1.86 components are mounted on the same shaft. The pressure
p9 4.82 and temperature at the inlet of the first-stage compressor
F I
1
1.333 1 are 1.5 bar and 20°C. The maximum cycle temperature and
T8 p8
Again,
T9
p9
GH JK
(1.86) 1.333 1.16 pressure are limited to 750°C and 6 bar. A perfect intercooler
is used between the two-stage compressors and a reheater
T8 898 is used between the two turbines. Gases are heated in the
T9 = = 774 K
1.16 1.16 reheater to 750°C before entering into the L.P. turbine.
T8 T9 898 T9 Assuming the compressor and turbine efficiencies as 0.82,
Also, turbine (L.P.) = ; 0.85 = calculate :
T8 T9 898 774
(i) The efficiency of the cycle without regenerator.
T9 = 898 – 0.85 (898 – 774) = 792.6 K
(ii) The efficiency of the cycle with a regenerator
Net work output = cpg(T8 – T9) × 0.95 whose effectiveness is 0.70.
= 1.15 (898 – 792.6) × 0.95 (iii) The mass of the fluid circulated if the power
= 115.15 kJ/kg developed by the plant is 350 kW.
Thermal ratio or effectiveness of heat exchanger, The working fluid used in the cycle is air. For air :
T5 T4 T5 428 = 1.4 and cp = 1.005 kJ/kg K.
T T 792.6 428 Solution. Given : T1 = 20 + 273 = 293 K,
9 4
T5 428 T5 = T7 = 750 + 273 = 1023 K,
i.e., 0.8 = p1 = 1.5 bar,
792.6 428
T5 = 0.8 (792.6 – 428) + 428 p2 = 6 bar, compressor = turbine = 0.82,
= 719.7 K Effectiveness of regenerator, = 0.70, Power
developed, P = 350 kW.
Now, Heat supplied
For air : cp = 1.005 kJ/kg, K, = 1.4
= cpg(T6 – T5) + cpg(T8 – T7)
As per given conditions : T1 = T3, T2 = T4
= 1.15 (898 – 719.7) + 1.15 (898 – 650)
F I
1
= 490.2 kJ/kg T2 p
GH JK
2
T1 p1
300 POWER PLANT ENGINEERING
=T ×G J
= turbine (L.P.)
2
Now, T2
HT K
1
1 and T7 = T5 = 1023 K
F 3 IJ
1.4 1
T T4
= 293 × G Effectiveness of regenerator, =
1.4
H 1.5 K = 357 K T8 T4
where T is the temperature of air coming out of regenerator
T2 T1 T 371
compressor (L.P.) =
T2 T1 0.70 =
872 371
357 293 i.e., T = 0.70 (872 – 371) + 371 = 722 K
0.82 =
T2 293 Net work available,
357 293 Wnet = [WT(L.P.) + WT(L.P.)] – [WC(H.P.) + WC(L.P.)]
T2 = + 293 = 371 K
0.82 = 2 [WT(L.P.) – WC(L.P.)]
i.e., T2 = T4 = 371 K as the work developed by each turbine is same and work
absorbed by each compressor is same.
T(K)
Wnet = 2cp [(T5 – T6) – (T2 – T1)]
r
ba
3
=
x
p
p
5 7 r
1023 ba Heat supplied per kg of air without regenerator
5
1.
=
p1 = cp(T5 – T4) + cp(T7 – T6)
872
6¢ 8¢ = 1.005 [(1023 – 371) + (1023 – 872)]
T¢
6 = 807 kJ/kg of air
8
2¢ Heat supplied per kg of air with regenerator
4¢
371
4 2 = cp(T5 – T ) + cp(T7 – T6)
293 = 1.005 [(1023 – 722) + (1023 – 872)]
3 1
s
= 454.3 kJ/kg
(i) thermal (without regenerator)
Fig. 5.56
146.73
= = 0.182 or 18.2%. (Ans.)
807
F I Fp I
1 1.4 1 (ii) thermal (with regenerator)
T5 p
GH JK G J
1.4
Now, 5 2
T6 p6 Hp K x =
146.73
454.3
= 0.323 or 32.3%. (Ans.)
LM ∵ p5 p2 OP :
(iii) Mass of fluid circulated, m
N p6 p Q x Power developed,
1023 6 FG IJ 0.286 kW
P = 146.73 × m
T6
3 H K 1.219
350 = 146.73 × m
1023 350
T6 = = 839 K i.e.,
m = 2.38 kg/s
1.219 146.73
T5 T6 i.e., Mass of fluid circulated = 2.38 kg/s. (Ans.)
turbine (H.P.) =
T5 T6 +Example 5.10. The air in a gas turbine plant is taken
1023 T6 in L.P. compressor at 293 K and 1.05 bar and after
0.82 =
1023 839 compression it is passed through intercooler where its
GAS TURBINE POWER PLANTS 301
r
ba
2
p2 p r
4.
Solution. Given : T1 = 293 K, T3 = 300 K, 4 = 2, 1023
6 ba
p1 p3 05
2.
7¢
T6 = 750 + 273 = 1023 K, r
5 ba
compressor = 82%, turbine = 82%, = 0.72, 7 1.0
a = 16 kg/s, C = 42000 kJ/kg,
m 8¢
5
4¢ 2¢ 8
4
cpa = 1.0 kJ/kg K, cpg = 1.15 kJ/kg K, 2 9
300
(for air) = 1.4, (for gas) = 1.33. 293
3
1
F I
1
1.4 1
T2 p
GH JK
2 ( 2) 1.4 1.219 (b) s (kJ/kg K)
T1 p1
T2 = 293 × 1.219 = 357 K Fig. 5.57
T4 T3
T2 T1 and compressor =
Also, compressor = T4 T3
T2 T1
365.7 300
0.82 =
357 293 T4 300
0.82 =
T2 293 FG 365.7 300 IJ + 300 = 380 K
i.e., T4 = H 0.82 K
FG 357 293 IJ + 293 = 371 K
T2 = H 0.82 K Work output of H.P. turbine = Work input to
compressor.
Neglecting mass of fuel we can write
F p I (2) 1.219
1
1.4 1
T4
G J
4 cpg (T6 – T7) = cpa [(T2 – T1) + (T4 – T3)]
Hp K
Similarly, 1.4
T3 3 1.15(1023 – T7) = 1.0[(371 – 293) + (380 – 300)]
T4 = 300 × 1.219 = 365.7 K or 1.15(1023 – T7) = 158
302 POWER PLANT ENGINEERING
15.8 2041.6
T7 = 1023 – = 886 K thermal =
1.15 6605.6
T6 T7 = 0.309 or 30.9%. (Ans.)
Also, turbine (H.P.) = (iii) Specific fuel consumption :
T6 T7
1023 886 If mf is the mass of fuel supplied per kg of air, then
i.e., 0.82 = mf × 42000 = 1.15(1023 – 664)
1023 T7
FG 1023 886 IJ = 856 K 1
42000
101.7
T7 = 1023 – H 0.82 K mf 1.15 (1023 664 ) 1
Air-fuel ratio = 101.7 : 1
F I
1
T6 p
GH JK
Fuel supplied per hour
Now, 6
T7 p7 16 3600
= = 566.37 kg/h
FT I
FG 1023 IJ 101.7
1.33
p6
G J
1 1.33 1 Specific fuel consumption
H 856 K
6
p7 HT K 7
2.05
566.37
p 4.2 = = 0.277 kg/kWh. (Ans.)
i.e., p7 = 6 = 2.05 bar 2041.6
2.05 2.05
[∵ p6 = 1.05 × 4 = 4.2 bar] +Example 5.11. Air is taken in a gas turbine plant at 1.1
bar 20°C. The plant comprises of L.P. and H.P. compressors
F I
1
F 2.05 IJ
1.33 1
and L.P. and H.P. turbines. The compression in L.P. stage
G
T7 p
GH JK
1.33
T8
7
p8 H 1.05 K = 1.18 is upto 3.3 bar followed by intercooling to 27°C. The pressure
of air after H.P. compressor is 9.45 bar. Loss in pressure
T7 886 during intercooling is 0.15 bar. Air from H.P. compressor
T8 = = 751 K is transferred to heat exchanger of effectiveness 0.65 where
1.18 1.18
it is heated by the gases from L.P. turbine. After heat
T7 T8 exchanger the air passes through combustion chamber. The
Again, turbine (L.P.) =
T7 T8 temperature of gases supplied to H.P. turbine is 700°C. The
gases expand in H.P. turbine to 3.62 bar and air then
886 T8
0.82 = reheated to 670°C before expanding in L.P. turbine. The
886 751 loss of pressure in reheater is 0.12 bar. Determine :
T8 = 886 – 0.82 (886 – 751) = 775 K (i) The overall efficiency (ii) The work ratio
(i) Power output : (iii) Mass flow rate when the power generated is
6000 kW.
Net power output= cpg (T7 – T8)
Assume : Isentropic efficiency of compression in both
= 1.15 (886 – 775) = 127.6 kJ/kg stages = 0.82.
Net output per second Isentropic efficiency of expansion in turbines = 0.85.
=m × 127.6 For air : cp = 1.005 kJ/kg K, = 1.4.
= 16 × 127.6 = 2041.6 kJ/s For gases : cp = 1.15 kJ/kg K, = 1.33.
= 2041.6 kW. (Ans.) Neglect the mass of fuel.
(ii) Thermal efficiency : Solution. Given : T1 = 20 + 273 = 293 K,
Effectiveness of heat exchanger, p1 = 1.1 bar, p2 = 3.3 bar,
T5 T4 T3 = 27 + 273 = 300 K,
= p3 = 3.3 – 0.15 = 3.15 bar,
T8 T4
p4 = p6 = 9.45 bar, T6 = 973 K,
T5 380 T8 = 670 + 273 = 943 K,
i.e., 0.72 =
775 380 p8 = 3.5 bar,
T5 = 0.72(775 – 380) + 380 = 664 K compressors = 82%, turbines = 85%,
Heat supplied in combustion chamber per second Power generated = 6000 kW,
Effectiveness, = 0.65, cpa = 1.005 kJ/kg K,
=m a cpg (T6 – T5)
air = 1.44, cpg = 1.15 kJ/kg K
= 16 × 1.15(1023 – 664) and gases = 1.33.
= 6605.6 kJ/s Refer to Fig. 5.58
GAS TURBINE POWER PLANTS 303
F I
1
F 3.5 IJ
T(K) 1.33 1
r
G
T8 p
GH JK
ba
1.33
Again, 8
H 1.1 K 1.332
r
r
45
ba
ba
T9 p9
9.
5
62
3.
6 T8 943
3.
973
r
T9 = = 708 K
ba
943 8 1.332 1.332
1
1.
T8 T9
7 7¢ 9¢ turbine (L.P.) =
T8 T9
9
5 943 T9
0.85 =
r 943 708
ba r
. 3 ba T9 = 943 – 0.85(943 – 708) = 743 K.
3 15
4¢ 2¢ 3. Effectiveness of heat exchanger,
4
T5 T4
2 = 0.65 =
300 T9 T4
293 3 1
T5 435
i.e., 0.65 =
s 743 435
Fig. 5.58 T5 = 0.65(743 – 435) + 435 = 635 K
Wturbine (H.P.) = cpg (T6 – T7)
F I
1
F 3.3 IJ
1.4 1
= 1.15(973 – 798)
G
T2 p
GH JK
1.4
Now,
T1
2
p1 H 1.1 K 1.369
= 201.25 kJ/kg of gas
T2 = 293 × 1.369 = 401 K Wturbine (L.P.) = cpg(T8 – T9)
T2 T1 401 293 = 1.15(943 – 743)
compressor (L.P.) = 0.82 =
T2 T1 T2 293 = 230 kJ/kg of gas
FG
401 293 IJ + 293 = 425 K Wcompressor (L.P.) = cpa(T2 – T1)
T2 =
H0.82 K = 1.005(425 – 293)
= 132.66 kJ/kg of air
Fp I
1
F 9.45 IJ 1.369
1.4 1
G
T4
G J
1.4
Wcompressor (H.P.) = cpa(T4 – T3)
H 3.15 K
4
Again,
T3 Hp K 3 = 1.005(435 – 300)
T4 = 300 × 1.369 = 411 K = 135.67 kJ/kg of air
T4 T3 Heat supplied = cpg(T6 – T5) + cpg(T8 – T7)
Now, compressor (H.P.) =
T4 T3
= 1.15(973 – 635) + 1.15(943
411 300
0.82 = – 798) = 555.45 kJ/kg of gas
T4 300
(i) Overall efficiency overall :
F 411 300 IJ + 300 = 435 K
T = GH
0.82 K
4
Net work done
overall =
Heat supplied
F p I FG 9.45 IJ
1 1.33 1
T
G J
1.33 [Wturbine (H.P.) Wturbine (L.P.) ]
H p K H 3.62 K
6 6
Similarly, 1.268
T7 7 [Wcomp. (L.P.) Wcomp. (H.P.) ]
=
T6 973 Heat supplied
T7 = = 767 K
1.268 1.268 (201.25 230) (132.66 135.67)
T6 T7 555.45
Also, turbine (H.P.) = 162.92
T6 T7 = 0.293 or 29.3%. (Ans.)
555.45
973 T7 (ii) Work ratio :
0.85 =
973 767 Net work done
Work ratio =
T7 = 973 – 0.85(973 – 767) = 798 K Turbine work
304 POWER PLANT ENGINEERING
F I
1
F 1I
C C.T. P.T. 1.34 1
G J
T4 p
GH JK
1.34
Generator
T3
4
p3 H 8K = 0.59
1173 T4 Solution. (a) Back work ratio may be defined as the ratio
or 0.86 = of negative work to the turbine work in a power plant. In
1173 692.1
gas turbine plants, air is compressed from the turbine
T4 = 1173 – 0.86(1173 – 692.1) exhaust pressure to the combustion chamber pressure. This
= 759.4 K work is given by – vdp. As the specific volume of air is
Consider 1 kg of air flow through compressor. very high (even in closed cycle gas turbine plants), the
compressor work required is very high, and also bulky
Wcompressor = cp (T2 – T1) = 1.005(595.4 – 288)
compressor is required. In steam power plants, the turbine
= 308.9 kJ exhaust is changed to liquid phase in the condenser. The
This is equal to work of compressor turbine. pressure of condensate is raised to boiler pressure by
condensate extraction pump and boiler feed pump in series
308.9 = m1 × cpg ( T3 – T4),
since the specific volume of water is very small as compared
neglecting fuel mass to that of air, the pump work (– vdp), is also very small.
308.9 From the above reasons, the back work ratio
or m1 = = 0.662 kg
1.128 (1173 759.4)
vdpz
and flow through the power turbine Turbine work
= 1 – m1 = 1 – 0.662 = 0.338 kg for gas turbine plants is relatively high compared to that
WPT = (1 – m1) × cpg(T3 – T4) for steam power plants.
(b) Refer to Fig. 5.60.
= 0.338 × 1.128 (1173 – 759.4)
= 157.7 kJ
Power output T
= 23 × 157.7 × mech. × gen. 5
Tmax
= 23 × 157.7 × 0.95 × 0.96
= 3307.9 kJ. (Ans.)
Qinput = cpgT3 – cpaT2
= 1.128 × 1173 – 1.005 × 595.4
= 724.7 kJ/kg of air
4¢
Thermal efficiency, 2¢
4 6¢
157.7 2
th = × 100 = 21.76%. (Ans.) 6
724.7
Example 5.13. (a) Why are the back work ratios relatively Tmin
3 1
high in gas turbine plants compared to those of steam power
s
plants ?
(b) In a gas turbine plant compression is carried out
in two stages with perfect intercooling and expansion in Fig. 5.60
one stage turbine. If the maximum temperature (Tmax K) Assuming optimum pressure ratio in each stage of
and minimum temperature (TminK) in the cycle remain the compressors as r , we have
constant, show that for maximum specific output of the
F I
1
plant, the optimum overall pressure ratio is given by T2 p
GH JK
2
T1 p1
F I
2
T
G JK
3( 1)
. C . max
ropt.
HT
Tmin
or T2 = Tmin × (r)
1
2
where = Adiabatic index ; T = Isentropic efficiency of
Wcompressor = 2[cp (T2 – T1)]
the turbine.
For both compressors
C = Isentropic efficiency of compressor. (N.U.)
306 POWER PLANT ENGINEERING
T T1 2c p
LM 1 OP Isentropic efficiency of turbine
Mechanical efficiency
= 88%
= 94%
2c p 2
C
T
C min
( r) MN 2
1P ,
Q Generation efficiency = 94%
as T1 = Tmin Combustion efficiency = 95%
Percentage of heat developed in the combustion
F I
1 1
T5 p chamber given to the air working into the system
GH JK
2
Also, 2 (r)
T6 p1 = 90%
Effectiveness of regenerator = 0.68
T5 Tmax
T6 = , as T5 = Tmax Cost of fuel used = ` 4500 per tonne
(r) 1/ (r) 1/
Calorific value of fuel used = 41000 kJ/kg
Wturbine = cp (T5 – T6) = cp Tmax
LM Tmax OP , All other charges including profit per hour
N ( r) 1/
Q T
= ` 3500/hour
T5 T6 Neglect heat and pressure losses in the system.
as T = Take cp for air = 1.005 kJ/kg K.
T5 T6
Solution. Given : T1 = 298 K ; T4 = 950 K ;
= cp Tmax
LM1 1 OP comp. = 82% ; turbine = 88% ;
N ( r) Q 1/ T
mech. = 94% ;
Wnet = Wturbine – Wcompressor gen. = 94% ; comb. = 95% ;
= cp T Tmax 1
LM 1 OP 2c p
Tmin [(r)
1
2
1]
= 0.68 ;
Cost of fuel used = ` 4500 per tonne ;
N (r) 1/ Q C
C = 41000 kJ/kg ;
For maximum work output, Other charges = ` 3500 per hour.
dWnet Cost of energy generated :
0
dr The schematic arrangement of the plant and its
FG 1IJ 1
or
FG
– cp T Tmax 1 (r)
IJ
H K corresponding T-s diagram are shown in Fig. 5.61 (a) and
H
K (b) respectively.
As the plant is designed for maximum specific
2c p
Tmin
FG 1IJ (r) 1
2
1
=0
output,
C H 2 K F I MN
L OP
p T Q
GH JK
2( 1)
Tmax rp = 2 C T 3
or T C = (r)3( – 1)/2, on simplification. p1 T1
Tmin
Hence, the optimum pressure ratio is L OP
= FG 0.82 0.88
950 I MN
1.4
J 2(1.4 1) Q
LM OP
2
ropt T . C .
Tmax 3( 1)
. Proved.
H 298 K
N Tmin Q = (2.3)1.75 = 4.3
Example 5.14. A gas turbine power plant of 12 MW Compressor :
capacity working on closed cycle, using air as working
F I
1
1.4 1
T2 p
GH JK
medium, is to be designed for maximum specific work 2 (4.3) 1.4 1.517
output. Find the cost of energy generated if the plant is T1 p1
running at designed capacity. Use the following data : T2 = 298 × 1.517 = 452 K
The temperature of air at inlet = 298 K
T2 T1 452 298
The maximum temperature in the cycle = 950 K C = 0.82 =
T2 T1 T2 298
Isentropic efficiency of compressor = 82%
GAS TURBINE POWER PLANTS 307
6 5¢ 86.31 ma = 12 × 103
ma = 139.03 kg/s
3
C.C. 5¢ 3-f supply Heat exchanger :
ü
ý
þ
2¢ Effectiveness of heat exchanger,
4 T3 T2
= (neglecting fuel mass)
C T T5 T2
T3 485.8
Alternator 0.68 =
665 485.8
1
C = Compressor or T3 = 485.8 + 0.68 (665 – 485.8) = 607.6 K
Water T = Turbine Combustion chamber :
cooler C.C. = Combustion chamber
Considering the combustion process in combustion
6 (a) Schematic arrangement of the chamber, we have :
gas turbine plant Now, mf × C × comb. × 0.9 = ma cpa (T4 – T3)
where mf is the mass of fuel burned per sec.
T or mf × 41000 × 0.95 × 0.9 = 139.03 × 1.005 (950 – 607.6)
p2 mf = 1.365 kg/s
4
1.365 3600
Cost of fuel = × 4500 = ` 17690.4/h
1000
p1
3
5
Total cost per hour = Cost of fuel / hour
2
2 6 + All other charges including profit per hour
5
= 17690.4 + 3500 = ` 21190.4/h
1 21190.4
Cost of energy generated =
s 12 103
(b) T-s diagram = ` 1.76/kWh. (Ans.)
Example 5.15. A gas turbine power plant works on constant
Fig. 5.61 pressure open cycle. It consists of compressor, generator,
combustion chamber and turbine (the compressor, turbine
452 298 and generator mounted on the same shaft). The following
T2 = 298 + = 485.8 K
0.82 data is given for this plant :
Turbine :
The pressure and temperature of air entering into
F I
1
1.4 1
T4 p the compressor = 1 bar, 25°C
GH JK
4 (4.3) 1.4 = 1.517
T5 p5 The pressure of air leaving the compressor
T4 950 = 4 bar
T5 = = 626.2 K
1.57 1.517 Isentropic efficiency of the compressor
T4 T5 950 T5 = 82 per cent
T = 0.88 =
T4 T5 950 626.2 Isentropic efficiency of the turbine = 86 per cent
Effectiveness of the regenerator = 72 per cent
T5 = 950 – 0.88 (950 – 626.2) = 665 K
Pressure loss in regenerator along air side
Work developed per hour (neglecting fuel mass)
= 0.08 bar
= ma × cpa [(T4 – T5 ) – ( T2 – T1)] × mech. × gen.
Pressure loss in regenerator along gas side
= 12 × 103 kW
= 0.08 bar
where ma is the mass of air passed per second.
ma × 1.005 [(950 – 665) – (485.8 – 298)] Pressure loss in the combustion chamber
× 0.94 × 0.94 = 12 × 103 = 0.04 bar
Combustion efficiency = 92 per cent
308 POWER PLANT ENGINEERING
ü
ý
þ
2¢ C.C.
Determine the following :
(i) The power available at the generator terminals, 4
(ii) The overall efficiency of the plant, and
C T
(iii) The specific fuel consumption.
C = Compressor Alternator
Take = 1.4 for air and gases. T = Turbine
cpa = 1 kJ/kg K ; cpg = 1.1 kJ/kg K. 1 C.C. = Combustion chamber
Solution. Given : p1 = 1 bar ; (a) Schematic arrangement of the
T1 = 25 + 273 = 298 K ; gas turbine plant
p2 = p2 = 4 bar ;
T
C = 82% ; T = 86% ;
= 0.72 ; comb. = 92% ; 4 bar
mech. = 94% ; gen. = 94% ; 3.88 bar
C = 40000 kJ/kg ; 4
ma = 24 kg/s ; patm. = 1.03 bar ; 1.11 bar
3 1.03 bar
T4 = 690 + 273 = 963 K. 2
2¢
5¢ 1 bar
The schematic arrangement of the plant and its 5
corresponding T-s diagram are shown in Fig. 5.62 (a) and
6
(b) respectively.
Pressure at the inlet to the turbine,
1
p4 = 4 – (0.08 + 0.04) = 3.88 bar s
(b) T-s diagram
Pressure at exit of the turbine,
p5 = 1.03 + 0.08 = 1.11 bar Fig. 5.62
Compressor : Combustion Chamber :
F I
1
FG 4 IJ
1.4 1 Considering the combustion process in combustion
T2 p
GH JK
1.4
T1
2
p1
H 1K = 1.486 chamber, we have
mf × C × comb. = (ma + mf) cpg (T4 – T3)
T2 = T1 × 1.486 = 298 × 1.486 = 442.8 K
F ma I
comp. = 0.82 =
T2 T1 442.8 298
GH f
JK
C × comb. = m 1 cpg (T4 – T3)
T2 T1 T2 298
T2 = 298 +
442.8 298
= 474.6 K Fm
40000 × 0.92 = G a
I
1J 1.1 (963 T )
Turbine :
0.82 or
Hm f K 3
33455 191.2 Example 5.16. The following data relate to a gas turbine
1 plant :
963 T3 T3 665.8
Power developed = 5 MW
33455 (963 T3 ) 191.2
or Inlet pressure and temperature of air to the
963 T3 T3 665.8 compressor = 1 bar, 30°C
32492 T3 191.2 Pressure ratio of the cycle = 5
963 T3 T3 665.8 Isentropic efficiency of the compressor = 80 per cent
(32492 + T3)(T3 – 665.8) = 191.2(963 – T3) Isentropic efficiency of both turbines = 85 per cent
32492 T3 – 21633174 + T32 – 665.8 T3 Maximum temperature in both turbines = 550°C
= 184126 – 191.2 T3 cpa = 1.0 kJ/kg K ;
2
T3 + 32017 T3 – 21817300 = 0 cpg = 1.15 kJ/kg K ;
(air) = 1.4 ; (gases) = 1.33.
32017 (32017)2 4 21817300 If a reheater is used between two turbines at a
T3 =
2 pressure 2.24 bar, calculate the following :
32017 33352 (i) the mass flow rate of air, and
= = 667.5 K
2 (ii) the overall efficiency.
i.e., T3 = 667.5 K Neglect the mass of the fuel. (P.U.)
ma Solution. Given : Power developed = 5 MW ;
and mf = 112 : 1. p1 = 1 bar ; T1 = 30 + 273 = 303 K ;
p3
(i) The power available at generator terminals: rp = = 5 or p3 = 5 × 1 = 5 bar ;
p1
Wcomp. = 1 × cpa ( T2 – T1) = 1 (474.6 – 298)
p2 = 2.24 bar ;
= 176.6 kJ/kg or air T3 = T5 = 550 + 273 = 823 K ;
Wturbine = (1 + mf) × cpg × (T4 – T5 ) comp. = 80%,
Turbine, T2 :
C.C. C.C.
F I
1
FG IJ
3-f supply 1.33 1
T5 p 2.24 1.33
GH JK
3
H K
ü
ý
þ
2¢ 3 4¢ 5
T6 p1 1
= (2.24) 0.2481 = 1.22
T5 823
C T1 T2 T6 = = 674.6 K
1.22 1.22
Alternator
T T6 823 T6
T2 0.85 5
1 6¢ T5 T6 823 674.6
C = Compressor T6 = 823 – 0.85 (823 – 674.6) = 696.9 K
Air in C.C. = Combustion chamber Exhaust
T1, T2 = Turbines (Wturbine)total = 2 cpg (T3 – T4) as T3 = T5
(a) Flow diagram for the plant and T4 = T6
= 2 × 1.15 (823 – 696.9)
T (K)
= 290 kJ/kg
p2
Wnet = (Wturbine)total – Wcomp.
p3
823 3 5 = 290 – 221.2 = 68.8 kJ/kg
a :
(i) The mass flow rate of air, m
p1 Power developed = ma × W
net
4¢
2¢ 5 × 10 = a × 68.8
3 m
6¢
4 3
a = 5 10 = 72.67 kg/s. (Ans.)
2
6 m
68.8
(ii) Overall efficiency, overall :
Heat supplied, Qs = cpg (T3 – T2) + cpg(T5 – T4)
303 = 1.15 [(823 – 524.2)
1
s + (823 – 696.9)] = 488.6 kJ/kg
(kJ/kg K)
(b) T-s diagram Wnet
overall =
Heat supplied (Qs )
Fig. 5.63
68.8
(480 303) =
T2 = 303 = 524.2 K 488.6
0.8
= 0.1408 or 14.08%. (Ans.)
Wcomp. = cpa(T2 – T1) = 1.0(524.2 – 303)
= 221.2 kJ/kg Example 5.17. The following data refer to a gas turbine
plant in which the compression is carried out in one stage
Turbine, T1 : and expansion is carried out in two stages with reheating
to the original temperature.
Fp I
1
F 5 IJ
1.33 1
T3
=G
Capacity of the gas turbine plant = 6 MW
GH p JK
1.33
H 2.24 K
2
=
T4 3
Temperature at which air is supplied = 20°C
Suction and exhaust pressure = 1 bar
FG 5 IJ 0.2481 Pressure ratio =6
=
H 2.24 K = 1.22 Maximum temperature limit = 750°C
Isentropic efficiency of compressor = 80 per cent
T3 823 Isentropic efficiency of each turbine = 84 per cent
T4 = = 674.6 K
1.22 1.22 Effectiveness of heat exchanger = 0.72
T3 T4 823 T4 Calorific value of fuel = 18500 kJ/kg
T1 0.85
T3 T4 823 674.6 cpa = 1 kJ/kg K ; cpg = 1.15 kJ/kg K ;
T4 = 823 – 0.85(823 – 674.6) = 696.9 K (air) = 1.4, (gas) = 1.33.
GAS TURBINE POWER PLANTS 311
F I
T1 = 20 + 273 = 293 K ; p1 = 1 bar ; 1
FG IJ
1.33 1
T4 p 6
GH JK
1.33
rp =
p3
p1
= 6 or p3 = 6 bar ; T5
3
p2
H
2.45 K
= (2.45)0.2481 = 1.249
T4 = T5 = 750 + 273 = 1023 K ;
T4 1023
comp. = 80%, T1 T2 = 84% ; T5 = = 819 K
1.249 1.249
= 0.72, C = 18500 kJ/kg ; T4 T5 1023 T5
cpa = 1 kJ/kg K ; cpg = 1.15 kJ/kg K ; T1 0.84
T4 T5 1023 819
(air) = 1.4 ; (gas) = 1.33. T5= 1023 – 0.84 (1023 – 819) = 851.6 K
The schematic arrangement of the gas turbine plant T1 T2 (Given), T5 = T7 = 851.6 K
and its corresponding T-s diagram are shown in Fig. 5.64
Regenerator :
(a) and (b) respectively.
Effectiveness,
p2 = p3 p1 6 1 = 2.45 bar
T3 T2 T3 537.6
Compressor : = 0.72 =
T7 T2 851.6 537.6
F I
1
1.4 1
T2 p
GH JK
T3 = 537.6 + 0.72 (851.6 – 537.6)
3 (6) 1.4
T1 p1 = 763.7 K
= (6)0.2857 = 1.668
(i) A/F ratio entering in the first turbine :
Exhaust Let mf1 = Mass of fuel supplied per kg of air to the
8
Regenerator combustion chamber (and hence to the first turbine)
(1 + mf1 ) cpg (T4 – T3) = mf1 × C
3 7 3- supply or (1 + mf1 ) × 1.15 (1023 – 763.7) = mf × 18500 1
2 C.C.
or 298.2 (1 + mf1 ) = 18500 mf1
4
298.2
C T1 T2 mf1 =
(18500 298.2)
Alternator = 0.01638 kg/kg of air
6
5 1
1 A/F ratio = = 61 : 1. (Ans.)
0.01638
Air in Reheater
C = Compressor T1, T2 = Turbines (ii) Thermal efficiency of the cycle, thermal :
C.C. = Combustion chamber Considering the flow with burning through the
(a) Schematic arrangement of the gas turbine plant reheater, we have
(1 + mf1 + mf2 ) cpg (T6 – T5) = mf2 × C
T (K)
m
where f2 is the fuel supplied in the reheater per kg of air
p3 p2
4 6 entering into the compressor.
1023
p1 (1 + 0.01638 + mf2 ) × 1.15 (1023 – 851.6)
T5 = T7 = mf2 × 18500
5 7
3 5 8 or 197.11(1.01638 + mf2 ) = 18500 mf2
2 7
2 or 200.34 + 197.11 mf2 = 18500 mf2
200.34
mf2 =
1 s (kJ/kg K) (18500 197.11)
(b) T-s diagram = 0.0109 kg/kg of air
Fig. 5.64
312 POWER PLANT ENGINEERING
Wcomp. = 1 × cpa(T2 – T1) = 1 × 1 × (537.6 – 293) Isentropic efficiency of power turbine (T2 )
= 244.6 kJ/kg of air = 89 per cent
WTurbine (total) = WT1 WT2 Calorific value of fuel
= (1 + mf1 ) cpg (T4 – T5) = 40500 kJ/kg
+ (1 + mf1 + mf2 ) cpg (T6 – T7) Combustion efficiency (comb.) in both the combustion
chambers = 94 per cent
= (1 + 0.01638) × 1.15(1023 – 851.6)
Mechanical efficiency (mech.) for both the turbines
+ (1 + 0.01638 + 0.0109)
= 89 per cent
× 1.15(1023 – 851.6)
Effectiveness of regenerator ()
= 1.15(1023 – 851.6) [(1 + 0.01638) = 0.72
+ (1 + 0.01638 + 0.0109)]
cpa = 1.005 kJ/kg K ; cpg = 1.1 kJ/kg K;
= 402.8 kJ/kg of air.
(for air) = 1.4 ; (for gases) = 1.35
Wnet = Wturbine (total) – Wcomp.
Neglecting pressure losses, heat losses and mass of
= 402.8 – 244.6 = 158.2 kJ/kg of air
fuel, determine :
Wnet Wnet
thermal = (i) Plant efficiency,
Heat supplied (Qs ) (mf1 mf2 ) C
(ii) Specific fuel consumption, and
158.2
= (iii) Air fuel ratio.
(0.01638 0.0109) 18500
Solution. Given : Capacity of the plant = 1500 kW ;
= 0.3135 or 31.35%. (Ans.)
(iii) Air supplied to the plant, ma : p1 = 1 bar ; T1 = 25 + 273 = 298 K ;
ma × Wnet = 6 × 1000 T4 = 750 + 273 = 1023 K ;
6000 6000 T6 = 800 + 273 = 1073 K ; p1 = 1 bar ;
ma = = 37.93 kg/s. (Ans.) p2 = 5 bar ;
Wnet 158.2
(iv) Fuel consumption of the plant per hour : T8 = 475 + 273 = 748 K ; comp. = 82% ;
Fuel consumption of the plant per hour T1 = 84% ; T2 = 89% ;
= ma (mf1 mf2 ) × 3600 C = 40500 kJ/kg ; comb. = 94% ;
= 37.93(0.01638 + 0.0109) × 3600 mech = 89%, = 0.72 cpa = 1.005 kJ/kg K ;
= 3725 kg/h. (Ans.) cpg = 1.1 kJ/kg K ; (for air) = 1.4 ;
Example 5.18. An open cycle constant pressure gas turbine (for gases) = 1.35.
power plant of 1500 kW capacity comprises a single stage The schematic arrangement of the plant and its
compressor and two turbines with regenerator. One turbine corresponding T-s diagram are shown in Fig. 5.65 (a) and
is used to run the compressor and other one runs the (b) respectively.
generator. Separate combustion chamber is used for each
Compressor :
turbine. Air coming out from the regenerator is divided
F I
1
F 5I
into two streams, one goes to compressor turbine and other 1.4 1
G J
T2 p
GH JK
1.4
to power turbine. The pressure and temperature of air
entering the compressor are 1 bar and 25°C. The maximum T1
2
p1 H 1K = (5)0.2857 = 1.584
temperature in the compressor turbine is 750°C and in T2 = T1 × 1.584 = 298 × 1.584 = 472 K
power turbine is 800°C. The maximum pressure in the
T2 T1 472 298
stream is 5 bar. The exhaust pressure of both turbine is comp. = 0.82 =
1 bar and both exhausts pass through the regenerator. T2 T1 T2 298
The temperature of exhaust entering the regenerator is 472 298
475°C. T2 = 298 = 510.2 K
0.82
Use the following data : Compressor turbine :
Isentropic efficiency of compressor (comp.)
F I
1
= 82 per cent 1.35 1
T4 p
GH JK
Isentropic efficiency of compressor turbine (T1 ) 2 (5) 1.35
T5 p1
= 84 per cent = (5)0.2592 = 1.518
GAS TURBINE POWER PLANTS 313
a2
GH m m JK
5
a1
a2
a2
7
6
ma ( ma1 ma2 ) = 23 kg/s ; 2
2 6
C = 42000 kJ/kg ;
cpa = 1.005 kJ/kg K ;
cpg = 1.128 kJ/kg K ; 1
s
air = 1.4 ; gas = 1.34. C–T2 (kJ/kg K)
The schematic arrangement of the plant and its
corresponding T-s diagrams (separately for C – T1 and (b) T-s diagrams
C – T2) are shown in Fig. 5.67 (a) and (b) respectively.
Fig. 5.67
Compressor-Turbine-1 (C – T1) :
T2 = T1 × 1.584 = 288 × 1.584 = 456.2 K
F I
1
1.4 1
T2 p
GH JK T2 T1 456.2 288
2 (5) 1.4 comp. = 0.76 = T T T 288
T1 p1 2 1 2
= (5)0.2857 = 1.584 456.2 288
T2 = 288 = 509.3 K
0.76
316 POWER PLANT ENGINEERING
Let mf1 = Fuel supplied in C. C – 1 Substituting the values in eqn. (i), we get
Then, f1 × C = ( ma1 + mf1 ) × cpg(T3 – T2)
m WT2 = (6.58 + 0.079) × 1.128(953 – 679.8)
Fm I (∵ T6 = T4 as per given conditions)
or C= GH m a1
f1
JK
1 × cpg(T3 – T2) = 2052.1 kJ/s. (Ans.)
or 42000 = G
Fm a1 I
1J × 1.128(953 – 509.3)
The capacity of turbine T2 to run the compressor,
WT1 = ma1 × cpa(T2 – T1)
Hm f1 K = 16.42 × 1.005(509.3 – 288)
ma1 42000 = 3651.9 kJ/s
1 = 82.92
mf1 1.128 (953 509.3) Total fuel consumed,
mf = mf1 + mf2
F I
1
1.34 1
T3 p
GH JK
Also, 2 (5) 1.34 = (5)0.254 = 1.5 = 0.198 + 0.079 = 0.277 kg/s
T4 p1
Thermal efficiency of the plant,
T3 953 WT2
T4 = = 635.3 K
1.5 1.5 thermal =
mf C
T3 T4 953 T4
T1 0.86 2052.1
T3 T4 953 635.3 =
T4 = 953 – 0.86(953 – 635.3) = 679.8 K 0.277 42000
= 0.1764 or 17.64%. (Ans.)
Now, the work required to run the compressor must
be equal to the work developed by T1. Example 5.21. A gas turbine plant consists of two-stage
ma × cpa(T2 – T1) = ( ma1 + mf1 ) × cpg(T3 – T4) compressor with intercooler and it is driven by a separate
Fm I turbine. The gases coming out from first turbine are passed
= mf1 GH m a1
f1
JK
1 × cpg(T3 – T4)
to the power turbine after reheating to the temperature which
is equal to the temperature at the inlet of the compressor
turbine. The power turbine generates the electrical energy.
or 23 × 1.005(509.3 – 288) = mf1 (82.92 + 1) A regenerator is used for heating the air before entering
× 1.128(953 – 679.8) into the combustion chamber by using the exhaust gases
or 5115.35 = 25861.6 mf1 coming out of power turbine.
Use the following data :
mf1 = 5115.35 = 0.198 kg/s
25861.6 Ambient air temperature and pressure
ma1 = 82.92 × 0.198 = 16.42 kg/s = 15°C, 1 bar
and ma2 = ma – ma1 = 23 – 16.42 Maximum cycle temperature
= 6.58 kg/s = 1000 K
Air mass flow = 20 kg/s
Compressor-turbine-2 (C – T2) :
Isentropic efficiency of each compressor
Work developed by the turbine T2, = 80 per cent
WT2 = ( ma2 + mf2 ) × cpg(T5 – T6) ...(i) Insentropic efficiencies of turbines :
T1 = 87% ; T2 = 80%
Considering the combustion chamber of turbine T2,
Pressure drop in intercooler
we can write
= 0.07 bar
mf2 × C = ( ma2 + mf2 ) × cpg(T5 – T2)
Pressure drop in regenerator (H.E.)
or mf2 × 42000 = (6.58 + mf2 ) × 1.128(953 – 509.3) = 0.1 bar in each side
= 500.49(6.58 + mf2 ) Effectiveness of heat exchanger
= 3293.22 + 500.49 mf2 = 0.75
Pressure drop in combustion chamber
3293.22
mf2 = = 0.079 kg/s = 0.15 bar
(42000 500.49) Pressure drop in reheater
F or ma2 I = 0.1 bar
GH mf2
6.58
0.079
83.3 JK Mechanical efficiency for compressor-turbine
= 99%
GAS TURBINE POWER PLANTS 317
1
= 2 × 20 × 1(367.2 – 288) = 3168 kW
C1, C2 = Compressor 8
Air in
T1, T2 = Turbines Compressor turbine :
T2
Power developed by the compressor turbine,
Alternator
(a) Schematic arrangement of the plant 3168 3168
WT1 = 3200 kW
mech 0.99
318 POWER PLANT ENGINEERING
PQ
Qs = cpg (T6 – T5) + cpg (T8 – T7)
N p T1
1.33
= cpg [(T6 – T7) + (T8 – T5)]
LM 1
OP = 1.1(145.45 + 1000 – 787.3) = 394 kJ/kg)
145.45 = 870 M1
MN o(r ) t PPQ
or 0.2481
Assuming mf is mass of fuel supplied per second in
p T1 combustion chamber and reheater, then,
Heat developed = Heat-gained by air
1
or 0.167 = 1 mf × C × comb. = 20 × 394
o(r ) t
p T1
0.2481
or mf × 43500 × 0.98 = 20 × 394
F 1 IJ
1 20 394
mf = = 0.185 kg/s
G
0.2481
(rp )T1
H 1 0.167 K = 2.09 43500 0.98
= 666 kg/h
p6 Specific fuel consumption (s.f.c.)
Also, (rp )T1 2.09
p7 666
= = 0.458 kg/kWh. (Ans.)
p6 3.61 1454
p7 = = 1.73 bar
2.09 2.09 (iii) Overall efficiency of the plant, overall :
p8 = p7 – (p)reheater = 1.73 – 0.1 Output
= 1.63 bar overall =
Input
p8 1.63 1454
(rp )T2 = 1.48 =
p9 1.1 20 394
where (rp )T1 and (rp )T2 are the pressure ratios of the = 0.1845 or 18.45%. (Ans.)
turbines T1 and T2.
GAS TURBINE POWER PLANTS 319
HIGHLIGHTS
1. The major fields of application of gas turbines are : A modified plant may have in addition an intercooler, a
(i) Aviation (ii) Power generation regenerator, a reheater etc.
(iii) Oil and gas industry (iv) Marine propulsion. 4. Methods for improvement of thermal efficiency of open
2. A gas turbine plant may be defined as one “in which the cycle gas turbine plant are :
principal prime mover is of the turbine type and the (i) Intercooling (ii) Reheating
working medium is a permanent gas”. (iii) Regeneration.
3. A simple gas turbine plant consists of the following : 5. Free-piston engine plants are the conventional gas turbine
(i) Turbine (ii) Compressor plants with the difference that the air compressor and
(iii) Combustor (iv) Auxiliaries. combustion chamber are replaced by a free piston engine.
THEORETICAL QUESTIONS
1. What are the major fields of application of gas turbine ? 12. Describe with neat sketches the working of a simple
2. State the limitations of gas turbines. constant pressure open cycle gas turbine.
13. Discuss briefly the methods employed for improvement of
3. List the applications of gas turbine plants.
thermal efficiency of open cycle gas turbine plant.
4. State the advantages and disadvantages of gas turbine 14. Describe with a neat diagram a closed cycle gas turbine.
power plants over diesel and thermal power plants. State also its merits and demerits.
5. What factors should be considered while selecting a site 15. Explain with a neat sketch the working of a constant
for a gas turbine power plant ? volume combustion turbine.
6. Give the description of a simple gas turbine plant. 16. Write a short note on fuels used for gas turbines.
7. Explain with the help of a neat diagram the energy cycle 17. What do you mean by “combination gas turbine cycles”.
for a simple-cycle gas turbine. Explain briefly combined gas turbine and steam power
plants.
8. Define the following performance terms :
18. List the advantages of ‘combined cycle’.
Air ratio, Pressure ratio, Work ratio, Compressor 19. How is a gas turbine ‘started’ and ‘shut down’ ?
efficiency, Engine efficiency, Machine efficiency,
20. Explain with a neat sketch the layout of a gas turbine
Combustion efficiency and Thermal efficiency.
power plant.
9. How are gas turbine power plants classified ? 21. Enumerate and explain briefly the components of a gas
10. How are gas turbines classified ? turbine power plant.
11. State the merits of gas turbines over I.C. engines and 22. With the help of neat sketches give the working of a free-
steam turbines. Discuss also the demerits over gas piston engine plant. State also the advantages and
turbines. disadvantages of such an arrangement.
UNSOLVED EXAMPLES
1. In an air standard gas turbine engine, air at a temperature 3. A gas turbine has a pressure ratio of 6/1 and a maximum
of 15°C and a pressure of 1.01 bar enters the compressor, cycle temperature of 600°C. The isentropic efficiencies of
where it is compressed through a pressure ratio of 5. Air the compressor and turbine are 0.82 and 0.85 respectively.
enters the turbine at a temperature of 815°C and expands Calculate the power output in kilowatts of an electric
to original pressure of 1.01 bar. Determine the ratio of generator geared to the turbine when the air enters the
turbine work to compressor work and the thermal compressor at 15°C at the rate of 15 kg/s.
efficiency when the engine operates on ideal Brayton cycle. Take : cp = 1.005 kJ/kg K and = 1.4 for the compression
Take : = 1.4, cp = 1.005 kJ/kg K. [Ans. 2.393 ; 37.03%] process, and take cp = 1.11 kJ/kg K and = 1.333 for the
2. In an open cycle constant pressure gas turbine air enters expansion process. [Ans. 920 kW]
the compressor at 1 bar and 300 K. The pressure of air 4. Calculate the thermal efficiency and the work ratio of
after the compression is 4 bar. The isentropic efficiencies the plant in example 3(above), assuming that cp for the
of compressor and turbine are 78% and 85% respectively. combustion process is 1.11 kJ/kg K.
The air-fuel ratio is 80 : 1. Calculate the power developed [Ans. 15.8% ; 0.206]
and thermal efficiency of the cycle if the flow rate of air is 5. The gas turbine has an overall pressure ratio of 5 : 1 and
2.5 kg/s. a maximum cycle temperature of 550°C. The turbine
Take cp = 1.005 kJ/kg K and = 1.4 for air and cpg = 1.147 drives the compressor and an electric generator, the
kJ/kg K and = 1.33 for gases. mechanical efficiency of the drive being 97%. The ambient
temperature is 20°C and the isentropic efficiencies of the
R = 0.287 kJ/kg K. Calorific value of fuel = 42000 kJ/kg. compressor and turbine are 0.8 and 0.83 respectively.
[Ans. 204.03 kW/kg of air ; 15.54%]
320 POWER PLANT ENGINEERING
Calculate the power output in kilowatts for an air flow of efficiency of the compressor is 0.80 and that of turbine
15 kg/s. Calculate also the thermal efficiency and the work 0.85. Calculate the efficiency of the plant. [Ans. 22.76%]
ratio. 10. In a marine gas turbine unit a high-pressure stage turbine
Neglect changes is kinetic energy, and the loss of pressure drives the compressor, and a low-pressure stage turbine
in combustion chamber. [Ans. 655 kW ; 12% ; 0.168] drives the propeller through suitable gearing. The overall
6. Air is drawn in a gas turbine unit at 17°C and 101 bar pressure ratio is 4 : 1, and the maximum temperature is
and the pressure ratio is 8 : 1. The compressor is driven 650°C. The isentropic efficiencies of the compressor, H.P.
by the H.P. turbine and the L.P. turbine drives a separate turbine, and L.P. turbine are 0.8, 0.83 and 0.85
power shaft. The isentropic efficiencies of the compressor, respectively, and the mechanical efficiency of both shafts
and the H.P. and L.P. turbines are 0.8, 0.85 and 0.83 is 98%. Calculate the pressure between turbine stages
respectively. Calculate the pressure and temperature of when the air intake conditions are 1.01 bar and 25°C.
the gases entering the power turbine, the net power Calculate also the thermal efficiency and the shaft power
developed by the unit per kg/s of mass flow, the work ratio when the mass flow is 60 kg/s. Neglect kinetic energy
and the thermal efficiency of the unit. The maximum cycle changes, and pressure loss in combustion.
temperature is 650°C. [Ans. 1.57 bar ; 14.9% ; 4560 kW]
For the compression process take 11. In a gas turbine unit comprising L.P. and H.P.
cp = 1.005 kJ/kg K and = 1.4 compressors, air is taken at 1.01 bar 27°C. Compression
For the combustion process and expansion process, take in L.P. stage is upto 3.03 bar followed by intercooling to
30°C. The pressure of air after H.P. compressor is 58.7
cp = 1.15 kJ/kg K and = 1.333
bar. Loss in pressure during intercooling is 0.13 bar. Air
Neglect the mass of fuel. from H.P. compressor is transferred to heat exchanger of
[Ans. 1.65 bar, 393°C ; 74.5 kW, 0.201 ; 19.1%] effectiveness 0.60 where it is heated by gases from L.P.
7. In a gas turbine plant, air is compressed through a turbine. The temperature of gases supplied to H.P. turbine
pressure ratio of 6 : 1 from 15°C. It is then heated to the is 750°C. The gases expand in H.P. turbine to 3.25 bar
maximum permissible temperature of 750°C and and are then reheated to 700°C before expanding in L.P.
expanded in two stages each of expansion ratio 6 , the turbine. The loss of pressure in reheated is 0.1 bar. If
air being reheated between the stages to 750°C. An heat isentropic efficiency of compression in both stages is 0.80
exchanger allows the heating of the compressed gases and isentropic efficiency of expansion in turbine is 0.85,
through 75 per cent of the maximum range possible. calculate : (i) Overall efficiency, (ii) Work ratio, (iii) Mass
Calculate : (i) The cycle efficiency, (ii) The work ratio, (iii) flow rate when the gas power generated is 6500 kW.
The work per kg of air. Neglect the mass of fuel.
The isentropic efficiencies of the compressor and turbine Take, for air : cp = 1.005 kJ/kg K, = 1.4
are 0.8 and 0.85 respectively. for gases : cpg = 1.15 kJ/hr K, = 1.3.
[Ans. (i) 32.75%; (ii) 0.3852; (iii) 152 kJ/kg] [Ans. (i) 16.17% ; (ii) 0.2215 ; (iii) 69.33 kg of air/s]
8. At the design speed the following data apply to a gas 12. In a gas turbine installation, air is taken in L.P.
turbine set employing the heat exchanger : Isentropic compressor at 15°C, 1.1 bar and after compression it is
efficiency of compressor = 75%, isentropic efficiency of the passed through intercooler where its temperature is
turbine = 85%, mechanical transmission efficiency = 99%, reduced to 22°C. The cooled air is further compressed in
combustion efficiency = 98%, mass flow = 22.7 kg/s, H.P. unit and then passed in the combustion chamber
pressure ratio = 6 : 1, heat exchanger effectiveness = 75%, where its temperature is increased to 677°C by burning
maximum cycle temperature = 1000 K. the fuel. The combustion products expand in H.P. turbine
which runs the compressor and further expansion is
The ambient air temperature and pressure are 15°C and
continued in the L.P. turbine which runs the alternator.
1.013 bar respectively. Calculate :
The gases coming out from L.P. turbine are used for
(i) The net power output,(ii) Specific fuel consumption, heating the incoming air from H.P. compressor and then
(iii) Thermal efficiency of the cycle. exhausted to atmosphere.
Take the lower calorific value of fuel as 43125 kJ/kg and Taking the following data determine :
assume no pressure-loss in heat exchanger and (i) Power output (ii) Specific fuel consumption
combustion chamber. (iii) Thermal efficiency :
[Ans. (i) 2019 kW; (ii) 0.4999 kg/kWh; (iii) 16.7%] Pressure ratio of each compressor = 2, isentropic efficiency
9. In a gas turbine plant air at 10°C and 1.01 bar is of each compressor stage = 85%, isentropic efficiency of
compressed through a pressure ratio of 4 : 1. In a heat each turbine stage = 85%, effectiveness of heat exchanger
exchanger and combustion chamber the air is heated to = 0.75, air flow = 15 kg/sec., calorific value of fuel = 45000
700°C while its pressure drops 0.14 bar. After expansion kJ/kg, cp(for gas) = 1 kJ/kg K, cp (for gas) = 1.15 kJ/kg K,
through the turbine the air passes through a heat (for air) = 1.4, (for gas) = 1.33.
exchanger which cools the air through 75% of maximum Neglect the mechanical, pressure and heat losses of the
range possible, while the pressure drops 0.14 bar, and the system and fuel mass also.
air is finally exhausted to atmosphere. The isentropic [Ans. (i) 1849.2 kW ; (ii) 0.241 kg/kWh ; (iii) 33.17%]
GAS TURBINE POWER PLANTS 321
15. (a) Discuss the factors to be kept in mind for selecting (b) Describe briefly the working of closed cycle gas turbine
the site of a nuclear power plant. plant with the help of T-s diagram.
(b) What is the function of moderator in a nuclear power (c) In a closed cycle gas turbine the following data were
plant ? What are the desirable properties of a good applied :
moderator ? Compare different moderators used in Working substance is air with cp = 0.24 and = 1.4
practice. Ambient temperature = 27°C
16. (a) Draw a neat diagram of nuclear reactor and explain Maximum temperature = 823°C
the function of its various components.
Pressure at compressor inlet = 1 kgf/cm2
(b) Explain with a neat sketch the principle of working of
magneto-hydrodynamic system of power generation. Pressure ratio =4
State the difficulties encountered in its design. Compressor efficiency = 80%
17. (a) What do you understand by a close cycle gas turbine Gas turbine efficiency = 85%
power plant ? List out its advantages over open cycle Determine the thermal efficiency of gas turbine.
plant. What difficulties are there in development of 20. In a 5 MW gas turbine generating set, HP turbine is used
close cycle plants ? to drive the compressor unit and LP turbine, mounted on
(b) Following observations were made during a test on separate shaft, drives the alternator. After two-stage
an open cycle constant pressure gas turbine plant : compression having overall pressure ratio of 9 with perfect
Inlet temperature = 27°C intercooling, the compressed air is supplied to the
Maximum temperature in the cycle = 800°C combustion chamber via a regenerator which receives the
Pressure ratio =6 exhaust from the LP turbine. The temperature of the gases
Isentropic efficiency of compressor = 85% at entry to the HP turbine is 727°C and the gases are
Isentropic efficiency of turbine = 90% reheated to 727°C again before entering the LP turbine.
Combustion efficiency = 95% Draw the schematic diagram of the plant and T-s diagram.
Mass flow of air = 100 kg/sec Considering open cycle, calculate (i) overall thermal
efficiency of the plant, and (ii) the mass flow rate of air in
Specific heat of air = 0.24
kg/sec.
Specific heat of gases = 0.26
Assume the following :
Specific heat ratio for air and gases = 1.4
Air inlet pressure and temperature 1 kg/cm2 and 27°C
Calorific value of fuel = 10,500 kcal/kg
respectively
Find : (i) Thermal efficiency of the plant ; (ii) Power
developed ; (iii) Air fuel ratio ; (iv) Specific fuel Isentropic efficiency of compressor in each stage = 0.8
consumption. Isentropic efficiency of expansion in each unit = 0.85
18. (a) Describe the functions of the major components used Mechanical efficiency of both the turbines = 0.98
in gas turbine plant. Thermal ratio of the regenerator = 0.75
(b) What are the factors to be considered in designing Combustion efficiency = 0.97
steam piping in thermal plant ? What are the cp air = 0.24 ; cp gas = 0.25 ; air = 1.4 ; gas = 1.33.
materials used for (i) steam piping, and (ii) its thermal
Neglect mass of fuel and consider the specific heat values
insulation ?
to be constant over the pressure and temperature range.
19. (a) What are the advantages of gas turbine plant over
other thermal power plants ?
Hydro-Electric Power Plant 6
6.1. Introduction. 6.2. Application of hydro-electric plants. 6.3. Advantages and disadvantages of hydro-electric plants.
6.4. Selection of site for a hydro-electric plant. 6.5. Essential features/elements of hydro-electric power plant—
Catchment area—Reservoir—Dam—Spillways—Conduits—Surge tanks—Prime movers—Draft tubes—Powerhouse and
equipment. 6.6. Classification of hydro-electric power plants—High head power plants—Medium head power plants—
Low head power plants—Base load plants—Peak load plants—Run-of-river plants without pondage—Run-of-river plant with
pondage—Storage type plants—Pumped storage plants—Mini and microhydel plants. 6.7. Hydraulic turbines—Classification
of hydraulic turbines—Description of various types of turbine—Specific speed of a turbine—Efficiencies of a turbine—
Cavitation—Performance of hydraulic turbine—Governing of hydraulic turbines—Selection of turbines. 6.8. Plant layout.
6.9. Hydro-plant auxiliaries. 6.10. Cost of hydro-plant. 6.11. Average life of hydro-plant components. 6.12. Hydro-
plant controls. 6.13. Electrical and mechanical equipment in a hydro-plant. 6.14. Combined hydro and steam power
plants. 6.15. Comparison of hydro-power station with thermal power stations. 6.16. Underground hydro-plants. 6.17.
Automatic and remote control of hydro-station. 6.18. Safety measures in hydro-electric power plants.
6.19. Preventive maintenance of hydro-plant. 6.20. Calculation of available hydro-power. 6.21. Cost of hydro-power.
6.22. Hydrology—Introduction—The hydrologic cycle—Measurement of run-off—Hydrograph—Flow duration curve—Mass
curve. 6.23. Hydro-power development in India—Worked Examples—Highlights—Theoretical Questions—Unsolved
Examples—Competitive Examinations Questions.
6.1. INTRODUC TION actually flows over the ground surface as direct run off and
forms the streams which can be utilised for hydro-schemes.
In hydro-electric plants energy of water is utilised to move First hydro-electric station was probably started in
the turbines which in turn run the electric generators. The America in 1882 and thereafter development took place
energy of water utilised for power generation may be kinetic very rapidly. In India the first major hydro-electric
or potential. The kinetic energy of water is its energy in development of 4.5 MW capacity named as Sivasamudram
motion and is a function of mass and velocity, while the Scheme in Mysore was commissioned in 1902. In 1914 a
potential energy is a function of the difference in level/head hydro-power plant named Khopoli project of 50 MW
of water between two points. In either case continuous capacity was commissioned in Maharashtra. The hydro-
availability of a water is a basic necessity ; to ensure this, power capacity, upto 1947, was nearly 500 MW.
water collected in natural lakes and reservoirs at high
Hydro (water) power is a conventional renewable
altitudes may be utilised or water may be artificially stored
source of energy which is clean, free from pollution and
by constructing dams across flowing streams. The ideal
generally has a good environmental effect. However the
site is one in which a good system of natural lakes with
following factors are major obstacles in the utilisation of
substantial catchment area, exists at a high altitude.
hydro-power resources :
Rainfall is the primary source of water and depends upon
such factors as temperature, humidity, cloudiness, wind (i) Large investments
etc. The usefulness of rainfall for power purposes further (ii) Long gestation period
depends upon several complex factors which include its (iii) Increased cost of power transmission.
intensity, time distribution, topography of land etc.
Next to thermal power, hydro-power is important
However it has been observed that only a small part of the
in regard to power generation. The hydro-electric power
rainfall can actually be utilised for power generation. A
plants provide 30 per cent of the total power of the world.
significant part is accounted for by direct evaporation, while
The total hydro-potential of the world is about 5000 GW.
another similar quantity seeps into the soil and forms the
In some countries (like Norway) almost total power
underground storage. Some water is also absorbed by
generation is hydrobased.
vegetation. Thus, only a part of water falling as rain
323
324 POWER PLANT ENGINEERING
6.2. APPLICATION OF HYDRO-ELECTRIC thermal plants run at a speed 3000 to 4000 r.p.m.
Therefore, there are no specialised mechanical
PLANTS problems or special alloys required for
Earlier hydro-electric plants have been used as exclusive construction.
source of power, but the trend is towards use of hydropower 15. The cost of land is not a major problem since the
in an inter connected system with thermal stations. As a hydro-electric stations are situated away from
self-contained and independent power source, a hydro-plant the developed areas.
is most effective with adequate storage capacity otherwise Disadvantages :
the maximum load capacity of the station has to be based
1. The initial cost of the plant is very high.
on minimum flow of stream and there is a great wastage of
water over the dam for greater part of the year. This 2. It takes considerable long time for the erection
increases the per unit cost of installation. By inter- of such plants.
connecting hydro-power with steam, a great deal of saving 3. Such plants are usually located in hilly areas
in cost can be effected due to : far away from the load centre and as such they
(i) reduction in necessary reserve capacity, require long transmission lines to deliver power,
subsequently the cost of transmission lines and
(ii) diversity in construction programmes,
losses in them will be more.
(iii) higher utilisation factors on hydroplants, and
4. Power generation by the hydro-electric plant is
(iv) higher capacity factors on efficient steam plants. only dependent on the quantity of water
In an inter connected system the base load is supplied available which in turn depends on the natural
by hydropower when the maximum flow demand is less than phenomenon of rain. So if the rainfall is in time
the stream flow while steam supplies the peak. When stream and proper and the required amount of can be
flow is lower than the maximum demand the hydroplant collected, the plant will function satisfactorily
supplies the peak load and steam plant the base load. otherwise not.
For wide valley with gentle Earth dam or Following are the causes of failure of earth dams :
side slopes rock fill dam. 1. Overtopping caused by insufficient spillway
3. Permeability of foundation material capacity.
When uplift pressure Arch dam 2. Seepage along conduits through the dam.
exerted on the base of the 3. Piping through the dam or its foundation.
dam is excessive 2. Rock-fill dams. A rock-fill dam consists of loose
When the foundations Earth dam rock of all sizes and has a trapezoidal shape with a wide
are pervious base, with a watertight section to reduce seepage. It is used
in mountaneous locations where rock rather than earth is
In addition to these factors the following points
available. A rock-fill dam may be destroyed if overtopped
should also be given consideration.
to any great extent, and so it needs a supplementary
(i) Suitable site for locating spillways sometimes spillway of adequate capacity.
affects the selection of the type of a dam.
(ii) The availability of construction material may B. Masonry dams :
sometimes dictate the choice. 1. Solid gravity dams. This type of dam is more
It may be mentioned that in general the most massive and bulky than the other types since it depends
permanent and safe dam will be found to be most on its weight for stability. Because of its weight it requires
economical one. a sound rock foundation. It may be used as a spillway
section for a dam of another type on sand or gravel
Description of dams
foundations if the stresses are limited and a suitable cut-
A. Fill dams : off is provided. On a rock foundation the base of a solid
1. Earth dams. For small projects, in particular, gravity dam which is 0.7 of the head usually results in a
dam constructed of earth fill or embankment are commonly satisfactory and economical section for either a bulkhead
used. Because of the great volume of material required, it or spillway section. On an earth foundation the base
is imperative that the fill be obtainable in the vicinity of generally equals the head.
dam site. 2. Buttress dam. A buttress dam has an inclined
upstream face, so that water pressure creates a large
downward force which provides stability against
Stone pitching overturning or sliding. The forces on the upstream face
are transmitted to a row of buttresses or piers. This type of
Impervious dam requires only about one-third the concrete needed for
material a solid gravity dam, but extra cost of reinforcing steel and
near wall framework and the skilled labour needed for the thinner
sections may largely offset the saving in concrete. The
Earth relatively thin sections of concrete in a buttress dam are
Rock
and gravel susceptible to damage from frost and temperature and may
require protection or precautionary measures.
Fig. 6.2. Earth dam.
Fig. 6.3 and Fig. 6.4 shows typical buttress dams.
The earth dams have the following advantages :
(i) It is usually cheaper than a masonry dam. Flat deck
(ii) It is suitable for relatively previous foundation.
(iii) It blends best with the natural surroundings. Buttress
Haunch
(iv) It is the most permanent type of construction if Section-AA
protected from corrosion.
Disadvantages of the earth dam are :
(i) It has greater seepage losses than most other
types of dams.
(ii) Since this type of dam is not suitable for a A
Struts
spillway structure, therefore it requires a A
supplementary spillway. Buttresses
(iii) It is subject to possible destruction or serious
damage from erosion by water either over-
topping the dam or seeping through it.
Fig. 6.3. Slab-and-buttress type.
328 POWER PLANT ENGINEERING
C. Timber dams :
When wood is plentiful and more durable materials
are not accessible timber is sometimes used for low dams
upto 12 m. In the early days, timber could be had for the
cutting, but most of the original timber dams have been
superseded by masonry or fill dams. Now-a-days wooden
dams are uncommon.
6.5.4. Spillways
When the water enters the reservoir basin, the level of
water in basin rises. This rise is arranged to be of temporary
nature because excess accumulation of water endangers
the stability of dam structure. To relieve reservoir of this
excess water contribution, a structure is provided in the
body of a dam or near the dam or on the periphery of a
basin. This safeguarding structure is called a spillway.
Fig. 6.4. Multiple-arch type.
A spillway should fulfil9 the following requirements:
3. Arch dam. Refer to Fig. 6.5. This type of dam
1. It should provide structural stability to the dam
resists the water force by being braced against the canyon
under all conditions of floods.
sides because of its curved shape. Few sites are suitable
2. It should be able to pass the designed flood
for the this type of dam, which requires a fairly narrow
without raising reservoir level above H.F.L. (high
valley with steep slopes of solid rock to support the outward
flood level).
thrust of the structure. An arch dam is not ordinarily used
for a spillway as the downstream face is too steep for the 3. It should have an efficient operation.
over- flowing water except for low discharges. It is generally 4. It should have an economical section.
necessary to provide a separate spillway for an arch dam, Types of spillways
either a tunnel or conduit type, a side-channel wasteway Following are some types of spillways :
at the end of the dam, or a spillway in another location.
(i) Overfall spillway or solid gravity spillway
F (ii) Chute or trough spillway
(iii) Side channel spillway
(iv) Saddle spillway
t (v) Emergency spillway
(vi) Shaft or glory hole spillway
R
R (vii) Siphon spillway.
r q
In the types from (i) to (v) water spills and flows
q f
over the body of the spillway whereas in the types (vi) and
(vii) water spills over the crest and then flows through the
body of the spillway.
(a) Plan The selection of type of spillway is generally based
on the type of the dam and the quantity of flood water to be
discharged below ; it also depends on the site conditions.
6.5.4.1. Overfall spillway or Solid gravity spillway
Refer to Fig. 6.6. This type of spillway is provided in case
of concrete and masonry dams. It is situated in the body of
the dam, generally in the centre. As it is provided in the
dam itself the length of dam should be sufficient to
accommodate the designed spillway crest.
This spillway consists of an ogee crest and a bucket.
Water spills and flows over the crest in the form of a rolling
sheet of water. The bucket provided at the lower end of the
(b) Section spillway changes the direction of the fast moving water. In
this process the excess energy of fast moving water is
Fig. 6.5. Typical arch dam : (a) Plan (b) Section. destroyed. The portion between the front vertical face and
HYDRO-ELECTRIC POWER PLANT 329
the lower nappe of sheet of water is filled with concrete to To maintain satisfactory flow conditions a sufficient
conform the profile of the spillway to the lower nappe. This longitudinal slope is given to the side channel.
type of construction practically avoids the development of
negative pressures. The section is always designed for 6.5.4.4. Saddle spillway
maximum head of water over the crest of spillway. A saddle spillway may be constructed when conditions are
not favourable for any of the types mentioned above. There
Crest H.F.L. may be some natural depression or saddle on the periphery
Upper nappe F.R.L. of the reservoir basin away from the dam as shown in
Lower nappe Fig. 6.8. The depression may be used as a spillway. It is
H.F.L. = High flood level essential that the bottom of the depression should be at full
Bucket F.R.L. = Full reservoir level reservoir level. For ideal conditions there should be good
rock formation at the site of a spillway.
and consequently the lower end is sealed. As the lower end Canal. A canal is an open waterway excavated in
is sealed the air gets entrapped in the lower limb. This air natural ground. It has to follow the contour of the ground,
is driven out by incoming water completely. This process with perhaps a slight gradient corresponding to the head loss.
of evacuating and filling the lower limb by water is known Flume. A flume is an open channel erected on the
as priming. Once the siphon is primed water starts flowing surface of supported above ground on a trestle. A flume
out till the level of the water in the reservoir falls below might be used with a canal to cross a ravine or where the
the level of the upper limb. Usually the lower end of the slope of the ground is greater than the hydraulic gradient.
upper limb is kept below full reservoir level. It prevents Tunnel. It is a closed channel excavated through a
blocking of the entrance due to the floating matter such as natural obstruction such as a ridge of higher land between
the dam and the powerhouse. A tunnel across a bend in
ice etc. Naturally if the water is emptied till the lower end
the river might be cheaper than a conduit that goes around.
of the upper limb emerges out the useful live storage is
Tunnels are also commonly used in diverting water from
lost. To break the siphon action at proper time, that is when one drainage area to another, where the divide between
the water level falls to F.R.L., an air vent is provided on watersheds is higher than the reservoir.
the crown as shown in Fig. 6.9. Thus when the water level Pipeline. A pipeline is a closed conduit usually
falls to F.R.L. air enters in the lower limb through air vent supported on or above the surface of the land. When a
and siphonic action is broken or stopped. pipeline is laid on the hydraulic gradient, it is called a
flow line.
Air vent Crown
Penstock. It is a closed conduit for supplying water
Full reservoir under pressure to a turbine.
level
Advantages and limitations of different types of
Lower limb
conduits :
Upper limb
Open channels are generally the least expensive, but
Inlet the cost of a flume increases with the height of the trestle.
Crest Step
Reservoir Where the land is fairly level at head water elevation
between the dam and powerhouse sites, a canal would be
feasible, but not many sites fit this requirement.
Tunnels are generally the most costly type of conduit
for a given length but are justified if their use results in
considerable saving in distance. While ordinarily tailraces
Fig. 6.9. Saddle siphon spillway.
are open channels, tunnels are used for the discharge from
an underground hydro-station.
6.5.5. Conduits
Penstocks are used where the slope is too great for a
A headrace is a channel which leads water to a turbine and canal, especially for the final stretch of the diversion system
a tailrace is a channel which conducts water from the where the land pitches steeply to the powerhouse. Surge
wheels. The conduit may be open or close. tanks or other measures are necessary to prevent damage
Open conduits ...... Canals and flumes in closed conduits due to abnormal pressures.
Close conduits ...... Tunnels, pipelines and Fig. 6.10 shows the combination of tunnel, flume,
penstocks and penstocks at a high-head development. The tunnel
intake regulates the flow between the reservoirs, while the — Wood-stave penstocks are used for heads upto
sluice gates at the entrance to the flume control the about 75 m and consist of treated timbers laid
discharge to that needed by the turbines. The regulating side by side to form a cylinder held together by
forebay has a small storage capacity to care for minor flow the steel hoops. The size and spacing of the
fluctuations. It has an automatic spillway to discharge hoops on a wood-stave pipe and the reinforcing
overflow when turbines shut down suddenly. steel in concrete increase with the head.
Penstocks : — Steel penstocks can be designed for any head,
with the thickness varying with the pressure
(i) How to calculate penstock thickness ?
and diameter. The minimum thickness of steel
The thickness of steel penstock which depends on plate is used for heads upto 45 m ; for lower
the water head hoop/circumferential stress allowed in the heads it may be more economical to use wood or
material can be calculated by using the following relation: concrete pipe rather than steel.
pd The strength of a penstock can be expressed as the
t
2f horse power it can carry. Since the size of a pipe depends
where t = Thickness of the penstock, on the flow, the product of head and flow determines both
p = Pressure due to water including water maximum stresses and power.
hammer = wH, w and H being specific weight — High pressure penstocks are fabricated in 6 to
of water and head of water respectively, 8 m lengths for mountaneous regions where
transportation is difficult. The manholes give
d = Diameter (internal) of the penstock,
access to the interior of the penstocks for
f = Permissible hoop/circumferential stress, and inspection and maintenance. Welded joints are
= Joint efficiency. preferable to riveted ones because of the higher
(ii) Number of penstocks to be used : friction losses in the latter. Steel penstocks are
To supply water to a number of turbines penstocks usually given protective coatings in the shop and
needed may be decided from the following alternatives : after erection.
— Penstocks are generally supported by concrete
1. To provide one penstock for each turbine
piers or cadles, although they may be laid on or
separately. In such a case water is supplied independently
in the ground. A bridge or trestle is used to carry
to each turbine from a separate penstock.
a penstock across a narrow defile. Anchors on
2. To use a single penstock for the entire plant. In steep grades support the weight of the fill
this case the penstock should have as many branches as penstock and also take the thrusts from water
the number of hydraulic turbines. pressure acting at angles in the pipe. It may be
3. To provide multiple penstocks but each penstock cheaper to bury small pipes, while penstocks are
should supply water to atleast two hydraulic turbines. sometimes covered to protect them from rock or
While selecting the number of penstocks to be used snow slides, prevent freezing, or eliminate
for supplying water to the turbines, the following points expansion joints. Buried penstocks are subject
need be considered : to corrosion, which can be eliminated or at least
greatly reduced by cathodic protection which
(a) Operational safety. As far as possible a single
prevents electrolysis from attacking the metal.
penstock should not be used for supplying to different
Exposed penstocks last longer and are more
turbines for generating power because any damage to this
accessible for inspection and maintenance.
penstock would mean shut down of the entire set of
turbines. 6.5.6. Surge Tanks
(b) Economy. From view point of economy, if the A surge tank is a small reservoir or tank in which the
length of penstock required is short then one penstock each water level rises or falls to reduce the pressure swings so
may be provided to the turbines, however for longer that they are not transmitted in full to a closed circuit. In
penstocks a single penstock or as few penstocks as possible general a surge tank serves the following purposes :
may be used.
1. To reduce the distance between the free water
(c) Transportation facilities. The penstock size surface and turbine thereby reducing the water-hammer
should be so selected that it is easily transported from one effect (the water hammer is defined as the change in
place to another. pressure rapidly above or below normal pressure
(iii) Penstock materials and their suitability : caused by sudden changes in the rate of water flow through
— Reinforced concrete penstocks are suitable upto the pipe according to the demand of prime mover) on
18 m head as greater pressures cause rapid penstock and also protect upstream tunnel from high
deterioration of concrete exposed to frost action. pressure rises.
332 POWER PLANT ENGINEERING
2. To serve as a supply tank to the turbine when the 1. Simple surge tank. A simple surge tank is a
water in the pipe is accelerating during increased load vertical stand pipe connected to the penstock as shown in
conditions and as a storage tank when the water is Fig. 6.11. In the surge tank if the overflow is allowed, the
decelerating during reduced load conditions. rise in pressure can be eliminated but overflow surge tank
Types of surge tanks is seldom satisfactory and usually uneconomical. Surge
The different types of surge tanks in use are : tanks are built high enough so that water cannot overflow
even with a full load change on the turbine. It is always
1. Simple surge tank
desirable to place the surge tank on grond surface, above
2. Inclined surge tank the penstock line, at the point where the latter drops rapidly
3. The expansion chamber and gallery type surge to the power house as shown in Fig. 6.11. Under the
tank circumstances when suitable site for its location is not
4. Restricted orifice surge tank available the height of the tank should be increased with
5. Differential surge tank. the help of a support.
Dam
Reservoir level Surge tank
Reservoir
Hydraulic gradient line
Tunnel
Penstock
Power
house
2. Inclined surge tank. When a surge tank is ‘bottom gallery’ must be below the lowest steady running
inclined (Fig. 6.12) to the horizontal its effective water level in the surge tank. Besides this the intermediate shaft
surface increases and therefore, lesser height surge tank should have a stable minimum diameter.
is required of the same diameter if it is inclined or lesser
diameter tank is required for the same height. But this
type of surge tank is more costlier than ordinary type as
construction is difficult and is rarely used unless the
topographical conditions are in favour.
Inclined surge
tank
Conduit
any designed retarding head. The size of the throttle 1. Impulse turbine. Here the pressure energy of
adopted is usually such as the initial retarding head is equal water is converted into kinetic energy when passed through
to the rise of water surface in the tank when the full load is the nozzle and forms the high velocity jet of water. The
rejected by the turbine (a case when there is closure of the formed water jet is used for driving the wheel.
gate valve). 2. Reaction turbine. In this case the water
pressure combined with the velocity works on the runner.
The power in this turbine is developed from the combined
action of pressure and velocity of water that completely fills
Surge tank the runner and water passage.
For more details on hydraulic turbines refer to
Arte 6.7.
6.5.8. Draft Tubes
The draft tube serves the following two purposes :
Restricted 1. It allows the turbine to be set above tail-water level,
orifice without loss of head, to facilitate inspection and
maintenance.
Conduit
2. It regains, by diffuser action, the major portion of
Fig. 6.14. Restricted orifice surge tank. the kinetic energy delivered to it from the runner.
At rated load the velocity at the upstream end of
Advantage. Storage function of the tank can be the tube for modern units ranges from 7 to 9 m/s,
separated from accelerating and retarding functions. representing from 2.7 to 4.8 m head. As the specific speed
Disadvantage. Considerable portion of water (it is the speed of a geometrically similar turbine running
hammer pressure is transmitted directly into the low under a unit head and producing unit power) is increased
pressure conduit. and the head reduced, it becomes increasingly important
In comparison to other types of surge tanks these to have an efficient draft tube. Good practice limits the
are less popular. velocity at the discharge end of the tube to 1.5 to 2.1 m/s,
5. Differential surge tank. Refer to Fig. 6.15. A representing less than 0.3 m velocity head loss.
differential surge tank has a riser with a small hole at its Types of draft tubes. The following two types of
lower end through which water enters in it. The function draft tubes are commonly used :
of the surge tank depends upon the area of hole. (i) The straight conical or concentric tube
(ii) The elbow type.
Properly designed, the two types are about equally
efficient, over 85%.
Riser
(i) Conical type. The conical type is generally used
on low-powered units for all specific speeds and, frequently,
on large high-head units. The side angle of flare ranges
from 4 to 6°, the length from 3 to 4 times the diameter and
the discharge area from four to five times the throat area.
Fig. 6.16 shows a straight conical draft tube.
Conduit
(ii) Elbow type. The elbow type of tube is now used (v) Relief valves
with most turbine installation. With this type the vertical (vi) Water circulating pumps
portion begins with a conical section which gradually (vii) Flow measuring equipment
flattens in the elbow section and then discharges
(viii) Air duct
horizontally through substantially regular sections to the
tailrace. Most of the regain of energy takes place in the (ix) Water circulating pumps
vertical portion, very little in the elbow section, which is (x) Switch board equipment and instruments
shaped to deliver the water to the horizontal portion so (xi) Oil circuit breakers
that the regain may be efficiently completed. Fig. 6.17 (xii) Reactors
shows an elbow type draft tube. One or two vertical piers (xiii) Low tension and high tension bar
are placed in the horizontal portion of the tube, for
(xiv) Storage batteries
structural and hydraulic reasons.
(xv) Cranes.
Small conical tubes are sometimes made entirely of
steel plate. Most tubes are made of concrete with a steel- Besides the above important equipment shops and
plate lining extending from the upper end to a point where offices are also provided in the power house.
the velocity has been sufficiently reduced (say 5 m/s) to
prevent erosion of the concrete. Sometimes the liner is 6.6. CLASSIFICATION OF HYDRO-
carried around the elbow. Pier noses are also lined where ELECTRIC POWER PLANTS
necessary to prevent erosion for structural reasons.
Hydro-electric power stations may be classified as follows:
A. According to availability of head
1. High head power plants
2. Medium head power plants
3. Low head power plants
B. According to the nature of load
1. Base load plants
Fig. 6.17. Elbow type draft tube. 2. Peak load plants
C. Accordingly to the quantity of water
6.5.9. Powerhouse and Equipment
available
A powerhouse should have a stable structure and its layout 1. Run-of-river plant without pondage
should be such that adequate space is provided around the
2. Run-of-river plant with pondage
equipment (such as turbines, generators, valves, pumps,
governors etc.), so that the dismantling and repairing may 3. Storage type plants
be easily carried out. 4. Pump storage plants
A powerhouse, mostly, comprises of the following 5. Mini and microhydel plants
sub-divisons : A. According to availability of head
1. The substructure. This part of the powerhouse The following figures give a rough idea of the heads
extends from top of generator to the soil or rock and houses under which the various types of plants work :
most of the generating equipment. In case of Francis and
(i) High head power plants 100 m and above
Kaplan turbines the substructure not only accommodates
various equipment but draft tube as well. (ii) Medium head power plants 30 to 500 m
2. Intermediate structure. It is that part of the (iii) Low head power plants 25 to 80 m.
structure which extends from the top of the draft tube to Note. It may be noted that figures given above overlap
top of generator foundation. each other. Therefore it is difficult to classify the plants
3. The superstructure. This part of the structure, directly on the basis of head alone. The basis, therefore,
lies above the generator level. It houses mostly the cranes technically adopted is the specific speed of the turbine used
which handle the heavy equipment in the substructures. for a particular plant.
Following important equipment may be provided in 6.6.1. High Head Power Plants
a power house
These types of plants work under heads 100 m and above.
(i) Hydraulic turbines Water is usually stored up in lakes on high mountains
(ii) Electric generators during the rainy season or during the reason when the
(iii) Governors snow melts. The rate of flow should be such that water can
(iv) Gate valves last throughout the year.
HYDRO-ELECTRIC POWER PLANT 335
Fig. 6.18 shows high head power plant layout. the stability of the main dam by erosion because they are
Surplus water discharged by the spillway cannot endanger separated. The tunnel through the mountain has a surge
chamber excavated near the exit. Flow is controlled by head
Headworks Surge chamber gates at the tunnel intake, butterfly valves at the top of
Spillway
Reservoir Tunnel the penstocks, and gate valves at the turbines. This type
Valve house of site might also be suitable for an underground station.
The Pelton wheel is the common prime mover used
in high head power plants.
Penstock
6.6.2. Medium Head Power Plants
Refer to Fig. 6.19. When the operating head of water lies
Power between 30 to 100 metres, the power plant is known as
house medium head power plant. This type of plant commonly
uses Francis turbines. The forebay provided at the
beginning of the penstock serves as water reservoir. In such
plants, the water is generally carried in open canals from
Fig. 6.18. High head power plant layout. The main dam, spillway, main reservoir to the forebay and then to the powerhouse
and powerhouse stand at widely separated locations. Water flows through the penstock. The forebay itself works as a surge
from the reservoir through a tunnel and penstock to the turbines. tank in this plant.
Tailrace
Draft tube
River
Tailrace
B. According to the nature of load firm capacity to the plant. During good flow conditions these
plants may cater to base load of the system, when flow
6.6.4. Base Load Plants reduces they may supply the peak demands. Head water
The plants which cater for the base load of the system are elevation for plant fluctuates with the flow conditions. These
called base load plants. These plants are required to supply plants without storage may sometimes be made to supply
a constant power when connected to the grid. Thus they the base load, but the firm capacity depends on the
run without stop and are often remote-controlled with which minimum flow of river. The run-of-river plant may be made
least staff is required for such plants. Run-of-river plants for load service with pondage, though storage is usually
without pondage may sometimes work as baseload plant, seasonal.
but the firm capacity in such cases, will be muchless.
6.6.7. Run-of-River Plant with Pondage
6.6.5. Peak Load Plants Pondage usually refers to the collection of water behind a
The plants which can supply the power during peak loads dam at the plant and increases the stream capacity for a
are known as peak load plants. Some of such plants supply short period, say a week. Storage means collection of water
the power during average load but also supply peak load in up stream reservoirs and this increases the capacity of
as and when it is there ; whereas other peak load plants the stream over an extended period of several months.
are required to work during peak load hours only. The run- Storage plants may work satisfactorily as base load and
of-river plants may be made for the peak load by providing peak load plants.
pondage. This type of plant, as compared to that without
C. According to the quantity of water available pondage, is more reliable and its generating capacity is less
dependent on the flow rates of water available.
6.6.6. Run-of-River Plants Without Pondage
6.6.8. Storage Type Plants
A run-of-river plant without pondage, as the name
indicates, does not store water and uses the water as it A storage type plant is one with a reservoir of sufficiently
comes. There is no control on flow of water so that during large size to permit carry-over storage from the wet reason
high floods or low loads water is wasted while during low to the dry reason, and thus to supply firm flow substantially
run-off the plant capacity is considerably reduced. Due to more than the minimum natural flow. This plant can be
non-uniformity of supply and lack of assistance from a firm used as base load plant as well as peak load plant as water
capacity the utility of these plants is much less than those is available with control as required. The majority of hydro-
of other types. The head on which these plants work varies electric plants are of this type.
considerably. Such a plant can be made a great deal more 6.6.9. Pumped Storage Plants
useful by providing sufficient storage at the plant to take
care of the hourly fluctuations in load. This lends some Refer to Fig. 6.21.
Dam
Head water pond
Penstock
Powerhouse with
pumps & turbines
Head
Tail water
pond
Dam
Pumped storage plants are employed at the places energy available. This water can be again used for
where the quantity of water available for power generation generating power during peak load periods. Pumping of
is inadequate. Here the water passing through the turbines water may be done seasonally or daily depending upon the
is stored in ‘tail race pond’. During low load periods this conditions of the site and the nature of the load on the
water is pumped back to the head reservoir using the extra plant.
HYDRO-ELECTRIC POWER PLANT 337
Such plants are usually interconnected with steam To reduce the cost of microhydel stations than that
or diesel engine plants so that off peak capacity of of the cost of conventional installation the following
interconnecting stations is used in pumping water and the considerations are kept in view :
same is used during peak load periods. Of course, the energy 1. The civil engineering work needs to be kept to a
available from the quantity of water pumped by the plant minimum and designed to fit in with already
is less than the energy input during pumped operation. existing structures e.g., irrigation, channels,
Again while using pumped water the power available is locks, small dams etc.
reduced on account of losses occurring in prime movers. 2. The machines need to be manufactured in a
Advantages. The pump storage plants entail the small range of sizes of simplified design, allowing
following advantages : the use of unified tools and aimed at reducing
the cost of manufacture.
1. There is substantial increase in peak load
capacity of the plant at comparatively low capital 3. These installations must be automatically
cost. controlled to reduce attending personnel.
4. The equipment must be simple and robust, with
2. Due to load comparable to rated load on the
easy accessibility to essential parts for
plant, the operating efficiency of the plant is
maintenance.
high.
5. The units must be light and adequately
3. There is an improvement in the load factor of
subassembled for ease of handling and transport
the plant. and to keep down erection and dismantling costs.
4. The energy available during peak load periods Microhydel plants (micro-stations) make use of
is higher than that of during off peak periods so standardised bulb sets with unit output ranging from 100
that inspite of losses incurred in pumping there to 1000 kW working under heads between 1.5 to 10 metres.
is over-all gain.
5. Load on the hydro-electric plant remains 6.7. HYDRAULIC TURBINES
uniform.
A hydraulic turbine converts the potential energy of water
6. The hydro-electric plant becomes partly
into mechanical energy which in turn is utilised to run an
independent of the stream flow conditions.
electric generator to get electric energy.
Under pump storage projects almost 70 per cent
power used in pumping the water can be recovered. In this
6.7.1. Classification of Hydraulic Turbines
field the use of “Reversible Turbine Pump” units is also The hydraulic turbines are classified as follows :
worth noting. These units can be used as turbine while (i) According to the head and quantity of water
generating power and as pump while pumping water to available.
storage. The generator in this case works as motor during (ii) According to the name of the originator.
reverse operation. The efficiency in such case is high and (iii) According to the action of water on the moving
almost the same in both the operations. With the use of blades.
reversible turbine pump sets, additional capital investment (iv) According to the direction of flow of water in the
on pump and its motor can be saved and the scheme can runner.
be worked more economically. (v) According to the disposition of the turbine shaft.
(vi) According to the specific speed Ns.
6.6.10. Mini and Microhydel Plants
1. According to the head and quantity of water
In order to meet with the present energy crisis partly, a available :
solution is to develop mini (5 to 20 m head) and micro (less (i) Impulse turbine—requires high head and small
than 5 m head) hydel potential in our country. The low quantity of flow.
head hydro-potential is scattered in this country and (ii) Reaction turbine—requires low head and high
estimated potential from such sites could be as much as rate of flow.
20,000 MW.
Actually there are two types of reaction turbines,
By proper planning and implementation, it is one for medium head and medium flow and the other for
possible to commission a small hydro-generating set up of low head and large flow.
5 MW with a period of one and half year against the period 2. According to the name of the originator :
of a decade or two for large capacity power plants. Several
(i) Pelton turbine—named after Lester Allen Pelton
such sets upto 1000 kW each have been already installed of California (USA). It is an impulse type of
in Himachal Pradesh, U.P., Arunachal Pradesh, West turbine and is used for high head and low
Bengal and Bhutan. discharge.
338 POWER PLANT ENGINEERING
(ii) Francis turbine—named after James Bichens The specific speeds for the various types of runners
Francis. It is a reaction type of turbine for are given below :
medium high to medium low heads and medium
small to medium large quantities of water. Type of turbine Type of runner Specific speed (Ns)
(iii) Kaplan turbine—named after Dr. Victor Kaplan.
It is a reaction type of turbine for low heads and
LM Slow 10 to 20
Penstock Runner
L
Nozzle L
= 2.5 – 2.8,
d
D
= 14 – 16,
d
Jet of water T
= 0.95, Notch (width) = 1.1d + 5 mm
Spear d
Fig. 6.23. The bucket dimensions.
Fig. 6.24 shows a section through horizontal-impulse
turbine.
Fig. 6.22. Pelton wheel.
Hydraulic
brake
Needle Penstock
gate
valve
Baffle
plate
Jet deflector
Tail water elevation Nozzle pipe
Cbl2 Cw
[ and a are mass density and area of jet (a = /4 d2)
2 respectively]
Outlet f b Now the work done by the jet on the runner per
C2
Cf 2 Cbl1 = Cbl2 second
Cr
2 = F × Cbl
= aC1 ( Cw Cw ) × Cbl ...(6.2)
1 2
Angle of
C1
deflection Work done/sec per unit weight of water striking
M N
Inlet L aC1 (Cw1 Cw2 ) Cbl
=
Cbl
1
Cr
1
Weight of water striking
Cw
1 aC1 (Cw1 Cw2 ) Cbl
=
aC1 g
Fig. 6.25. Velocity triangles.
1
= (Cw1 Cw2 ) Cbl ...(6.3)
Cw1 is also known as velocity of whirl at inlet g
The energy supplied to the jet at inlet is in the form
Cf1 is also known as velocity of flow at inlet
1
of kinetic energy and is equal to mC2.
C2 = Velocity of jet, leaving the vane or 2
velocity of jet at outlet of the vane. Kinetic energy (K.E.) of jet per second
Cr2 = Relative velocity of the jet with respect 1
= (aC1) × C12
2
to the vane at outlet.
Hydraulic efficiency,
= Angle made by the relative velocity Cr ,
2 Work done per second
with the direction of motion of vane at h =
K. E. of jet per second
outlet and also called vane angle at outlet.
aC1 (Cw1 Cw2 ) Cbl
= Angle made by the velocity C2 with the =
1
direction of motion of the vane at outlet. ( aC1 ) C12
2
Cw2 and Cf2 = Components of the velocity C2, in the
2(Cw1 Cw2 ) Cbl
direction of motion of vane and = ...(6.4)
C12
perpendicular to the direction of motion
of vane at outlet. Now, Cw1 = C1, Cr1
Cw2 is also called the velocity of whirl at outlet = C1 – Cbl1 = (C1 – Cbl)
Inlet. The velocity triangle at inlet will be a straight and Cw2 = Cr2 cos – Cbl2
line where = Cr cos – Cbl
2
Cr1 = C1 – Cbl1 = C1 – Cbl
= (C1 – Cbl) cos – Cbl
Cw1 = C1, = 0 Substituting the value of Cw and Cw in eqn. (6.4),
1 2
and =0 we get:
Outlet. From the velocity triangle at outlet, we have 2[C1 (C1 Cbl ) cos Cbl ] Cbl
h =
Cr = Cr (assuming no friction)
2 1 C12
HYDRO-ELECTRIC POWER PLANT 341
2[(C1 Cbl ) (C1 Cbl ) cos ] Cbl 4. The mean diameter or the pitch diameter D of
= the Pelton wheel is given by
C12
DN
2(C1 Cbl ) (1 cos ) Cbl Cbl =
= ...(6.5) 60
C12
60Cbl
The efficiency will be maximum for a given value of or D=
C1 when N
d D
(h ) 0 5. Jet ratio (M) = (= 12 for most cases) ...(6.8)
dCbl d
Max. h =
2 N
2 C1
Q
2 filled with water.
C12 Francis turbines
C C Refer to Fig. 6.26 (a), (b). The modern Francis water
2 1 (1 cos ) 1
= 2 2 turbine is an inward mixed flow reaction turbine i.e. the
C12 water under pressure, enters the runner from the guide
FG 1 cos IJ vanes towards the centre in radial direction and discharges
=
H 2 K ...(6.7) out of the runner axially. The Francis turbine operates
under medium heads and also requires medium quantity
Important relations for Pelton wheel : of water. It is employed in the medium head power plants.
1. The velocity of the jet at inlet is given by This type of turbine covers a wide range of heads. Water is
brought down to the turbine and directed to a number of
C1 = Cv 2 gH stationary orifices fixed all around the circumference of
where Cv = Coefficient of velocity = 0.98 or 0.99 and H = Net the runner. These stationary orifices are commonly termed
head on turbine. as guide vanes or wicket gates.
2. The velocity of wheel (Cbl) is given by The head acting on the turbine is partly transformed
into kinetic energy and the rest remains as pressure head.
Cbl = 2 gH There is a difference of pressure between the guide vanes
where = Speed ratio. It varies from 0.43 to 0.48. and the runner which is called the reaction pressure and is
3. The angle of deflection of the jet through buckets responsible for the motion of the runner. That is why a
is taken as 165° if no angle of deflection is given. Francis turbine is also known as reaction turbine.
342 POWER PLANT ENGINEERING
(a)
C1
Shaft Guide blades Cr Cf
a 1 q 1
Spiral casing
Cbl
1
Cw
1
From penstock zero. Hence the work done by water on the runner per
second will be
In Francis turbine the pressure at the inlet is more Important relations for Francis turbine :
than that at the outlet. This means that the water in the 1. The ratio of width of the wheel to its diameter
turbine must flow in a closed conduit. Unlike the Pelton varies from 0.10 to 0.40.
type, where the water strikes only a few of the runner
Cf1
buckets at a time, in the Francis turbine the runner is 2. Flow ratio = and varies from 0.15 to 0.30.
always full of water. The moment of the runner is affected 2 gH
by the change of both the potential and the kinetic energies Cbl1
of water. After doing its work the water is discharged to 3. The speed ratio = and varies from 0.6
2 gH
the tail race through a closed tube of gradually enlarging to 0.9.
section. This tube is known as draft tube. It does not allow
Fig. 6.28 shows a plate-steel spiral-case setting of
water to fall freely to tail race level as in the Pelton turbine.
vertical Francis turbine, welded casing.
The free end of the draft tube is submerged deep in the tail
HYDRO-ELECTRIC POWER PLANT 343
Permanent magnet
generator for governor Maximum
tail water
Generator
Fig. 6.28. Plate-steel spiral-case setting of vertical Francis turbine, welded casing.
Propeller and Kaplan turbines is modification of propeller turbine the runner blades are
The need to utilize low heads where large volumes adjustable and can be rotated about pivots fixed to the boss
of water are available makes it essential to provide a large of the runner. The blades are adjusted automatically by
flow area and to run the machine at very low speeds. The servo-mechanism so that at all loads the flow enters them
propeller turbine is a reaction turbine used for heads without shock.
between 4 m and 80 m, and has a specific speed ranging Kaplan turbines have taken the place of Francis
from 300 to 1000. It is purely axial-flow device providing turbines for certain medium head installations. Kaplan
the largest possible flow area that will utilize a large volume turbines with shoping guide vanes to reduce the overall
of water and still obtain flow velocities which are not too dimensions are being used.
large.
Shaft
Vanes
Water inlet
from penstock
Scroll
Main casing
shaft Scroll
casing
Guide
vane
Tail Guide
Runner Flow Boss race wheel
blade Link
Runner
blade
Draft
tube
(b) (c)
Crane
Crane
Governor cabinet
Motor Head
generator water
set
Cable
Tail water
trays
Fig. 6.31. Cross-section of typical low head concrete spiral-case setting, with Kaplan turbine.
submerged in a stream of water. The economical harnessing head for axial flow turbines. As this energy cannot be used
of fairly low heads on major rivers is now possible with in the runner, therefore, it becomes necessary to find a
high-output bulb turbines. way out to extract this energy. An expanding pressure
Fig. 6.33 shows a power station (87300 kW) under a conduit hermetically fixed at runner outlet and having the
head of 10 m, provided with six 14550 kW bulb sets running other end below the minimum tail water level helps to
at 125 r.p.m. convert the velocity head into pressure or potential head.
This expanding device is called draft tube. Draft tube is
an integral part of mixed and axial flow turbines. Because
of the draft tube it is possible to have the pressure at runner
outlet much below the atmospheric pressure.
The draft tube serves the following two purposes :
1. It allows the turbine to be set above tail-water
level, without loss of head, to facilitate inspection
and maintenance.
2. It regains, by diffuse action, the major portion of
the kinetic energy delivered to it from the runner.
At rated load, the velocity at the upstream end of
20.80 m 22.80 m
the tube for modern units ranges from 7 to 9 m/s,
Fig. 6.33. Power station—using bulb turbines. representing from 2.7 to 4.8 m head. As the specific speed
(it is the speed of a geometrically similar turbine running
Runaway speed under a unit head and producing unit power) is increased
‘Runaway speed ’ is the maximum speed, governor and the head reduced, it becomes increasingly important
being disengaged, at which a turbine would run when there to have an efficient draft tube. Good practice limits the
is no external load but operating under design head and velocity at the discharge end of the tube from 1.5 to 2.1 m/s,
discharge. All the rotating parts including the rotor of representing less than 0.3 m velocity head loss.
alternator should be designed for the centrifugal stresses Draft tube theory : Consider a turbine fitted with
caused by this maximum speed. a draft tube (conical) as shown in Fig. 6.34.
The practical values of run away speeds for various
Turbine casing
turbines with respect to their rated speed N are as follows :
Pelton wheel ... 1.8 to 1.9 N
Francis turbine (mixed flow) ... 2.0 to 2.2 N 2 V2 2
Inlet of draft tube
Kaplan turbine (axial flow) ... 2.5 to 3.0 N
Hs Draft tube
Draft tube y2
Atmospheric
In the case of mixed and axial flow turbines only a pressure (pa)
part of available energy is converted into velocity energy Tailrace
at the inlet to the runner ; the rest is in the form of pressure
y
energy. This residual pressure is converted into velocity in
the runner, as a consequence of which the outlet velocity
increases. With the increase in the value of specific speed 3 V3 3
2
Outlet of draft tube
Ns, the exit velocity energy V2 increases compared with Fig. 6.34. Draft tube theory.
2g
H (the available energy). Let y = Distance of the bottom of draft tube from
In the Pelton Wheel all the available energy is tail race, and pa = atmospheric pressure at the surface of
converted into velocity energy before it strikes the wheel. tailrace.
As such it works under atmospheric conditions and the Applying Bernoulli’s equation to the section 2-2
wheel has to be placed above the maximum tail water level. (representing the runner exit or inlet of the draft tube)
The loss of energy due to exit velocity varies from 1 to 4%. and the section 3-3 (representing the draft tube exit) ;
In the case of mixed and axial flow turbines a large assuming section 3-3 as the datum line, we have:
portion of the energy is associated with the water as it p2 V22 p V2
y2 3 3 0 hf ...(i)
leaves the runner. This exit energy varies from 4 to 25% w 2g w 2g
for mixed flow turbines and from 20 to 50% of the total where, hf = Loss of energy between sections 2-2 and 3-3.
HYDRO-ELECTRIC POWER PLANT 347
p2
Rewriting the above expression (i) for , we obtain:
w
p2 p V 2 V32F I
w
3 y2 2
w 2g GH
hf JK ...(ii)
p3 p
Substituting a + y in expression (ii), we get:
w w
p2 pa V 2 V32 F I
w
w
( y y2 ) 2
2g GH
hf JK
The term (y2 – y) which represents the vertical
distance between the runner exit and the tail water level Fig. 6.35. Straight conical draft tube.
is called the suction head of draft tube and is denoted
V22 V32
by Hs. Correspondingly the factor is called the Vertical
2g leg
dynamic head.
p2 p F
V 2 V32 I
w
a Hs 2
w 2g GH hf JK ...[6.10 (a)]
Horizontal leg
p2
In eqn. [6.10 (a)], is less than atmospheric
w Fig. 6.36. Elbow type draft tube.
pressure.
The efficiency of a draft tube (d) is defined as 2. Elbow type. The elbow type of tube is used with
the ratio of net gain in pressure head to the velocity head at most turbine installations. This type of draft tube is
entrance of draft tube. Thus designed to turn the water from the vertical to the horizontal
direction with a minimum depth of excavation and at the
Net gain in pressure head same time having a high efficiency. The transition from a
d = circular section in the vertical leg to a rectangular section
Velocity head at entrance of draft tube
in the horizontal leg takes place in the bend. The horizontal
FV 2
V32 I portion of the draft tube is generally inclined upwards to
GH 2
2g
hf JK lead the water gradually to the level of the tail race and to
= ...(6.11) prevent entry of air from the exit end. The exit end of the
V22 draft tube must be totally immersed in water. Fig. 6.36
2g shows an elbow type draft tube. One or two vertical piers
where, V2 = Velocity of water at section 2-2 are placed in the horizontal portion of the tube, for
(inlet of draft tube). structural and hydraulic reasons.
V3 = Velocity of water at section 3-3 Moody spreading draft tube. Fig. 6.37 shows a
Moody’s spreading draft tube. It is provided with a solid
(outlet of draft tube).
central core of conical shape which reduces whirling action
V22 V32 V2 of discharge water. The efficiency of such a draft tube is
hf d 2 ...[6.11 (a)]
2g 2g about 85%. It is suited particularly for helical flows which
Types of draft tubes : occur when the water leaves the runner with a whirl
component.
The following two types of draft tubes are commonly
used :
1. The straight conical or concentric tube ;
2. The elbow type.
Solid conical
Properly designed, the two types are about equally core
efficient, over 85 per cent.
1. Conical type. The conical type draft tube is
generally used on low-powered units for all specific speeds,
frequently, on large-head units. The side angle of flare
ranges from 4 to 6°, the length from 3 to 4 times the
diameter and the discharge area from four to five times Fig. 6.37. Moody’s spreading draft tube or ‘Hydrocone’.
the throat area. Fig. 6.35 shows a straight conical
draft tube.
348 POWER PLANT ENGINEERING
Francis turbine :
Q D2 H GH N JK H
1. For the same power developed Kaplan turbine
is more compact in construction and smaller in
LM∵ From eqn. (v), D
H OP
size. MN N PQ
2. Part-load efficiency is considerably high. H H 3/ 2
3. Low frictional losses (because of small number H
N2 N2
of blades used).
Substituting the value of Q in eqn. (ii), we get:
6.7.3. Specific Speed of a Turbine
H 3/ 2 H5/2
The specific speed of a turbine is defined as the speed of a P 2
×H
N N2
turbine which is identical in shape, geometrical dimensions,
blade angles, gate opening etc., with the actual turbine but H5/2
P=K
of such a size that it will develop unit horse power when N2
working under unit head. where, K = constant of proportionality.
The specific speed may be derived as follows : If P = 1 kW, H = 1 m, the speed N = specific speeds
The overall efficiency (o) of any turbine is given by Ns. Substituting these values in the above equation, we get:
Power available at the shaft of the turbine K 15 / 2
o = 1= or Ns2 = K
Power supplied at the inlet of the turbine N s2
HYDRO-ELECTRIC POWER PLANT 349
Unit Quantities : u V V H
Let us consider a single unit. When the head on the r ...(6.13)
u Vr V H
unit is changed/varied then the speed of an ungoverned If the discharges are Q and Q then
turbine changes. The velocities at various points do not
change direction but their magnitudes vary in proportion Q V N H
...(6.14)
to the square root of the head. Q V N H
At a given point in the turbine under a head H, let If the power outputs are P and P then
V = Absolute velocity, P QH H H FG IJ
H
3/ 2
Vr = Relative velocity,
P Q H
H
H
H K
H
...(6.15)
F∵ Q H I
u = Peripheral velocity, and
V, Vr, u = Corresponding values at a different head
GH Q
J
H K
H, then as velocity is proportional to The hydraulic efficiency of the turbine under these
H , we have two heads may be considered to be nearly same, as the
velocity triangles at these heads are similar at a point.
350 POWER PLANT ENGINEERING
2. Mechanical efficiency (m). It is defined as the in water hammer. The intense pressure is accompanied by
ratio of power available at the shaft of the turbine (known a considerable vibration and noise.
as S.H.P. or B.H.P.) to the power developed by the runner. Cavitation factor. Prof. Dietrich Thoma of Munich
Power available at the shaft of the turbine (Germany) suggested a cavitation factor (sigma) to
m = determine the zone where turbine can work without being
Power developed by the runner
...(6.26) affected from cavitation. The critical value of cavitation
factor (c) is given by
3. Volumetric efficiency (v). The ratio of the
volume of the water actually striking the runner to the ( Ha Hv ) h
c = ...(6.28)
volume of water supplied to the turbine is called volumetric H
efficiency. where, Ha = Atmospheric pressure head in metre of water,
Volume of water actually striking the runner Hv = Vapour pressure in metre of water
v = corresponding to the water temperature,
Volume of water supplied to the turbine
...(6.27) H = Working head of turbine (difference between
head race and tailrace level in metres), and
4. Overall efficiency (o). It is defined as the ratio
of power available at the shaft of the turbine to the power h = Height of turbine outlet above tailrace level
supplied by the water at the inlet of the turbine. in metres.
Power available at the shaft of the turbine The values of critical factor depends upon the
o = specific speed of the turbine (Refer to Table 6.2).
Power supplied at the inlet of the turbine
Shaft power P Methods to avoid cavitation :
=
Water power wQH The following methods may be used to avoid
If g is the efficiency of a generator, then power cavitation :
output of a hydro-unit (turbine + hydro generators) 1. Runner/turbine may be kept under water. But it
= (wQH) × o × g. is not advisable as the inspection and repair of
the turbine is difficult. The other method to avoid
6.7.5. Cavitation cavitation zone without keeping the runner
It is known that when velocity of flow increases, the under water is to use the runner of low specific
pressure falls. In liquids, the pressure cannot fall below speed.
vapour pressure which depends upon the temperature and 2. The cavitation free runner may be designed to
height above mean sea level of the site. In any turbine part fulfil the given conditions with extensive
if the pressure drops below the evaporation pressure, the research.
liquid boils and a large number of small bubbles of vapour 3. It is possible to reduce the cavitation effect by
are formed. These bubbles mainly formed on account of selecting materials which can resist better the
low pressure are carried by the stream to higher pressure cavitation effect. The cast steel is better than cast
zones where the vapours condense and the bubbles iron and stainless steel or alloy steel is still better
suddenly collapse, as the vapours are condensed to liquid than cast steel.
again. This results in the formation of a cavity and the 4. The cavitation effect can be reduced by polishing
surrounding liquid rushes to fill it. The streams of liquid the surfaces. That is why the cast steel runners
coming from all directions collide at the centre of cavity and blades are coated with stainless steel.
giving rise to a very high local pressure whose magnitude 5. The ‘cavitation’ may be avoided by selecting a
may be as high as 7000 atmospheres. Formation of cavity runner of proper specific speed for given head.
and high pressure are repeated many thousand times a
second. This causes pitting on the metallic surface of runner Table 6.2. Cavitation factors
blades or draft tube. The material then fails by fatigue, Francis Kaplan
added perhaps by corrosion. During this process some parts
like runner blades may be torn away completely. Ns c Ns c
‘Cavitation’ may thus be defined as the 50 0.04 300 to 450 0.35 to 0.40
“phenomenon which manifests itself in the pitting of the 100 0.05 450 to 550 0.40 to 0.45
metallic surfaces of turbine parts because of formation of 150 0.07 550 to 600 0.46 to 0.6
cavities”.
200 0.1 650 to 700 0.85
During ‘cavitation’ the cavities may be formed on 250 0.14 700 to 800 1.05
the solid surface or near to it. In case it does not form on 300 0.2 – –
solid surface, the pressure generated in the cavity is
350 0.27 – –
propagated by the pressure waves similar to ones occurring
352 POWER PLANT ENGINEERING
Performance parameters
gH
Head co-efficient or parameter, P
N 2 D2 2 3/2
Capacity or discharge parameter, rD H
h
Q Q
or
ND3 D2 H Q
2
Power co-efficient, D gH
P P
or
N 3 D5 D2 H 3 / 2
0 ND
Efficiency of operation, . gH
The laws of performance are stated as follows from (a) Dimensionless turbine curves
the fact that each of these parameters should remain
constant for the same machine or a family of similar
machines : Deriaz
60% Propeller
N P/
The specific speed, Ns =
( gH )5 / 4 Pelton (Impulse)
1/2 G.O.
1/4 G.O.
H = Constant
Full G.O.
Unit power (Pu)
3/4 G.O.
1/2 G.O. H = Constant
H = Constant
Full G.O.
o
Centrifugal
governor
Lever
Piston rod of control valve
Sleeve
Fulcrum Relay or control valve
To turbine
main shaft
V1
Oil pump
V2
Piston rod
of relay
cylinder Spear
L
Oil sump M
Governing of reaction turbines valve better known as ‘Pressure Regulator’. When the guide
Refer to Fig. 6.44. The guide blades of a reaction vanes have to the suddenly closed, the relief valve opens
turbine are pivoted and connected by levers and links to and diverts the water direct to the tailrace. Its function is
the regulating ring. To the regulating ring are attached therefore, similar to that of deflector in Pelton turbines.
two long regulating rods connected to the regulating lever. Thus the double regulation, which is the simultaneous
The regulating lever is keyed to a regulating shaft which operation, of two elements is accomplished by moving the
is turned by a servomotor piston of oil pressure governor. guide vanes and relief valve in Francis turbines, by the
The penstock which feeds the turbine inlet, has a relief governor.
Connected to oil
pressure governor
Spiral casing
piping
Servomotor
Regulating Close
Regulating
rod
shaft Open
Regulating Regulating
lever ring
Turbine
Inlet
Fig. 6.45 shows the speed governing systems for by hydraulic turbines schematically.
6.7.8. Selection of Turbines value of cavitation factor also effects the design of turbine,
especially of Kaplan, propeller and bulb types.
The following points should be considered while selecting
the right type of hydraulic turbine : 6. Disposition of turbine shaft. Experience has
shown that the vertical shaft arrangement is better for
1. Specific speed. High specific speed is essential
large-sized reaction turbines, therefore it is almost
where head is low and output is large, because otherwise
universally adopted. In case of large size impulse turbine,
the rotational speed will be low which means cost of turbo- horizontal shaft arrangement is mostly employed.
generator and power house will be high. On the other hand
7. Head. (i) Very high heads (350 m and above). For
there is practically no need of choosing a high value of
heads greater than 350 m, Pelton turbine is generally
specific speed for high head installations, because even with employed and there is practically no choice except in very
low specific speed, high rotational speed can be attained special cases.
with medium capacity plants.
(ii) High heads (150 m to 350 m). In this range either
2. Rotational speed. Rotational speed depends on Pelton or Francis turbine may by employed. For higher
specific speed. Also the rotational speed of an electrical specific speeds Francis turbine is more compact and
generator with which the turbine is to be directly coupled, economical than the Pelton turbine which for the same
depends on the frequency and number of pair of poles. The working conditions would have to be much bigger and
value of specific speed adopted should be such that it will rather cumbersome.
give the synchronous speed of the generator.
(iii) Medium heads (60 m to 150 m). A Francis turbine
3. Efficiency. The turbine selected should be such is usually employed in this range. Whether a high or low
that it gives the highest overall efficiency for various specific speed unit would be used depends on the selection
operating conditions. of speed.
4. Part load operation. In general the efficiency (iv) Low heads (below 60 m). Between 30 to 60 m
at part-loads and overloads is less than normal. For the heads both Francis and Kaplan turbines may be used. The
sake of economy the turbine should always run with latter is more expensive but yields a higher efficiency at
maximum possible efficiency to get more revenue. part loads and overloads. It is therefore preferable for
When the turbine has to run at part or overload variable loads. Kaplan turbine is generally employed for
conditions Deriaz turbine is employed. Similarly, for low heads under 30 m. Propeller turbines are, however,
heads, Kaplan turbine will be useful for such purposes in commonly used for heads upto 15 m. They are adopted only
place of propeller turbine. when there is practically no load variation.
5. Cavitation. The installation of water turbines (v) Very low heads. For very low heads bulb turbines
of reaction type over the tailrace level is effected by are employed these days. Although Kaplan turbines can
cavitation. The critical value of cavitation factor must be also be used for heads from 2 m to 15 m but they are not
obtained to see that the turbine works in safe zone. Such a economical.
HYDRO-ELECTRIC POWER PLANT 357
6.8. PL ANT L AYOUT turbine main shaft and sufficient pressure is usually
maintained in the oil tanks during the shut down, so that
The plant layout is considerably affected by the nature of the turbine can be started. A stand-by motor driven pump
project. is also installed for emergency service. The lubricating oil
In low head plants, the width of the dam is usually pumps may be driven from the turbine shaft and would
small and suitable space for fixing the turbines and work as soon as the unit starts. Sometimes a stand-by
generators is limited. On the other hand, in high head lubricating pump is also installed.
schemes the site for the power plants can be selected more During starting of hydro-plants the following
conveniently to give desired layouts. auxiliaries are not directly needed :
The size and type of units proposed to be installed (i) Coolant pumps
also affect the layout of the power station. (ii) Air compressors
For reaction machines with vertical single runner,
(iii) Drainage pumps
the arrangement with the machines in a line parallel to
(iv) Fans and cooling oil pumps
the length of the turbine house is usually preferred ; the
spacing between two units being controlled by the width of (v) Cranes
the flume or scroll case at entrance to the runner or the (vi) Gate hoists
width of the draft tube at its month, or sometimes by the (vii) Valves
overall diameter of the alternator. Horizontal machines of (viii) Battery charging units etc.
the reaction type are best located at right angles to the length
These auxiliaries are generally electrically driven.
of the turbine house while for impulse machines with
Water may be used to cool the bearings of the turbine and
horizontal setting the wheel shaft is placed parallel to the
generator and transformers and is circulated through water
longitudinal axis of the turbine house.
pumps. Air compressors maintain a supply of air under
Unlike the reaction machines, the spacing of the pressure for operation of generator brakes and other uses
impulse machines is fixed by the machine dimensions and in the power station. Unwatering of turbine pits may be
necessary clearances rather than by the penstock flume or required during repairs or check up for which water pumps
tailrace, as the amount of water discharged is are necessary. Fans are required for ventilation of the
comparatively small. For impulse machines with vertical turbine and switch gear room or for cooling transformers.
setting the arrangement with centres on a line parallel to Oil pumps handle transformer oil through the cleaning and
axis of turbine house is suggested. The use of such machines cooling system. Cranes are required during machinery
is rare. repairs and installations to lift heavy parts or place them
in position. The head works control gates with hoists which
6.9. HYDRO-PLANT AUXILIARIES may be manually or electrically operated. Storage batteries
The following auxiliaries are essential for starting the are needed to supply low voltage D.C. power for switch
generating unit : gear control. During failure of the main generators lighting
(i) Exciter and power for the station may also be obtained from the
batteries.
(ii) Governor oil system
Most of the station auxiliaries are electrically driven
(iii) Lubricating oil pump.
due to obvious advantages of using such drivers.
The station can start usually independent of
external power, but stand-by auxiliaries are needed for 6.10. COST OF HYDRO-PLANT
emergency service. Exciter for the main generator may be
direct connected, motor-generator type engine driven or The cost of hydro-plant varies from ` 850 to ` 950 per kW
auxiliary water turbine driven. Direct connected exciters of capacity. A typical subdivision of investment under
make the unit independent of auxiliary power and also have various items (e.g. as dam, tailrace, reservoir, turbines,
higher efficiency than the other types. Motor generator generators, land, building and foundations, switching and
exciters depend upon electric power for starting, whereas wiring, switchyard etc.) is as follows :
an engine driven exciter is an independent unit. The 1. Reservoir, dam, intake, tailrace 35%
efficiency of water turbine driven exciter is very low and 2. Turbines and generators 20%
this is not suited for any other use except during emergencies.
3. Land, building and foundations 30%
The exciter is an essential piece of equipment and it is
important to select a drive that is reliable and at the same 4. Switching and wiring 5%
time reasonably low in first cost and operation. The 5. Switchyard 5%
pressurised oil system for the governor is driven from the 6. Miscellaneous 5%
358 POWER PLANT ENGINEERING
6.11. AVERAGE LIFE OF HYDRO-PLANT 4. Voltage control of generator and system. The
voltage regulators are employed to ensure that electric
COMPONENTS power is supplied at proper voltage.
The average life (approximate) of various components of 5. Machine protection. In a hydro-plant provision
hydro-electric power plant is given below : of protective devices should be made to guard against
Components Average life (years) breakdown of turbo-generator and auxiliary services, like
transformers, switchgears, overhead lines etc. Protection
1. Reservoirs 70–80
measures are also required to guard against incorrect
2. Dams operation and failure of control system.
(i) Earthen, concrete or masonry 150 Automatic controls are efficient, safe and reliable
(ii) Loose rock 60 The control room should be designed for convenience
3. Water ways of operation and the equipment should be so arranged/
(i) Canals, tunnels 50–100 spaced that it is easily accessible.
(ii) Penstocks
6.13. ELECTRICAL AND MECHANICAL
(a) Steel 40–50
EQUIPMENT IN A HYDRO-PLANT
(b) Concrete 25–50
4. Powerhouse and equipment In an hydro-electric power plant the electrical and
(i) Building 35–50 mechanical equipment comprise of the following :
(ii) Generators 25 A. Electrical equipment
(iii) Transformers 30 In electrical equipment the following elements items
are included :
(iv) Turbines (hydraulic) 5
(i) Generators
(v) Pumps 20–25
(ii) Exciters
(iii) Voltage regulators
6.12. HYDRO-PLANT CONTROLS
(iv) Transformers
The various controls which are provided in an hydro-electric (v) Switchgear
power plant are enumerated and discussed below : (vi) Control room equipment.
1. Hydraulic controls Generators. The generators employed in a hydro-
2. Machine controls—Starting and stopping plant are usually 3-phase synchronous machines and have
3. Machine controls—Loading and frequency either a vertical shaft arrangement or horizontal shaft
arrangement ; but vertical shaft arrangement is preferred.
4. Voltage control of generator and system
The generator cooling may be achieved by air
5. Machine protection. circulation through the stator ducts. Cooling by water
1. Hydraulic controls. In a hydro-plant the cooled heat exchangers is common.
following hydraulic controls are provided : The power output of a 3-phase alternator is given by:
(i) Storage level indicators—primary and secondary
P = 3 VI cos ×10–6 MW
(ii) Flood control
where, P = Power output,
(iii) River flow control
V = Voltage (in volts),
(iv) Intake gate control. I = Current (in amperes), and
2. Machine controls—Starting and stopping. cos = Power factor (varies from 0.9 to 0.95).
The control of water flowing to the turbine is exercised by
Transformers. These may be of single phase or
providing gates and valves in the supplying conduit and at
three phase type. They are oil filled for insulation and
the turbine inlet. The quantity of water flowing to the
cooling purposes. The generated voltage is stepped up by
turbine is regulated according to the load on the generator
means of step up transformers. Transformers may be of
by the use of a governor system. While starting the turbines
power or distribution type.
the casing should be filled gradually and to limit the rate
of water flow by-pass valves are provided. Switchgear. A switchgear consists of switches,
isolators, surge arrestors and circuit breakers. Its main
3. Machine controls—Loading and frequency.
function is to make and break the circuits.
The load on the machine is controlled as follows :
For generated voltage it is preferred to locate
(i) By adjusting the governor speed control
switchgear indoors whereas outdoor location is used for
(ii) By controlling system frequency. transmission voltage.
HYDRO-ELECTRIC POWER PLANT 359
When switchgears and transformers are located The above objectives (unless a country/region is rich
outside they should be provided adequate lightening either in abundant supply of cheap fuel or ample water
protection. power resources which can be developed at suitable site)
Control room equipment. It performs the can be best realised by a judicious combination of both
following functions : (i) Machine starting and stopping, hydro and thermal power. Hydro-power represents a
(ii) Generator and system voltage control, (iii) Machine renewable source of energy which enjoys many intrinsic
loading control, (iv) Frequency control, (v) Hydraulic advantages as compared to thermal power. Although the
control, (vi) Machine running control. cost of construction of hydro power plant is nearly same as
B. Mechanical equipment that of a coal based steam power plant in terms of
investment for MW, but hydro-power plant uses water for
Mechanical equipment include the following :
power generation which is available in abundance in
(i) Compressors and air ducts nature.
(ii) Shaft, coupling, bearings etc. It is known as that hydro-plant can meet the
(iii) Braking equipment for the generator demands of load variations more rapidly and easily. Thus,
(iv) The oil circuits and pumps when the rate of flow of water is low, the steam plant can
(v) Cranes and other lifting equipment work at constant load producing a better efficiency and the
hydro-plant will work most effectively as peak load plant
(vi) Ventilation and cooling systems
and its output can be varied to meet the load fluctuations.
(vii) Equipment for water supply and drainage The steam and hydro-plants reverse their functions (steam
(viii) Equipment for power house lighting. plant providing the peak load and the hydro-plant providing
base load) when high rate of water flow is available. But
6.14. COMBINED HYDRO AND STEAM even under this condition, the steam plant output will
POWER PLANTS remain constant and the hydro-plant output will be varied
to meet the load fluctuations.
An electrical power system should fulfil the following
objectives : 6.15. COMPARISON OF HYDRO-POWER
1. To ensure an adequate and reliable electric power STATION WITH THERMAL POWER
supply at all loads and at all times.
STATIONS
2. The source of energy should be such as to give
the minimum overall cost of the system as a The comparison between hydro-power stations and thermal
whole. power stations is given below :
3. Cost of energy generation Immune to inflation. Very much influenced by the increase in
the cost of fuel.
4. Life of plant Long useful life. Not so long comparatively. The component
parts deteriorate and become obsolete at
a faster rate.
5. Pollution Free from problems of pollution. Causes pollution and sub-sequently create
health hazards.
6. Design, construction and Simple in design, robust in construction and Comparatively more complicated in
reliability reliable in operation. design, less robust in construction and less
reliable in operation.
7. Running below a certain Can be run Cannot be run
minimum load factor.
8. Reserve capacity and varia- Particularly suited to provide reserve capacity Comparatively not suited for the
tion in power demands. as well as meeting the exacting needs of daily mentioned requirements.
variation in power demands.
360 POWER PLANT ENGINEERING
6.16. UNDERGROUND HYDRO-PLANTS In the tail development the power house is placed
at the surge end of the low pressure tunnel. This requires
The conventional hydro-plant is usually located overground a short tailrace. Access tunnels and shafts are necessary
at the foot of a dam or a hill slope on the banks of a river. in both types. Between these two extreme layouts there is
The first of these plants was set up in U.S.A as far back as a wide range of intermediate possibilities for plant location.
1898. Since then several underground stations have been Before taking a decision in favour of the
set up in Germany, France, Sweden, Switzerland and other underground station, thorough geological investigations of
countries. the site are essential. Rock should be properly tested to devise
Consideration supporting the construction of economical tunneling method which may considerably affect
underground hydro-plants the cost of construction of the power station.
1. A suitable site for a conventional surface station/ Advantages of the underground Powerhouse/
plant and good slope for penstock not available. Station
2. There may be danger of falling rocks and snow 1. Better rock bearing properties.
avalanches particularly in narrow valleys. 2. Foundation difficulties are easier to come.
3. Availability of underground sound rock and 3. In planning the design and location of the
avoidance of a long pressure tunnel and facility principal works surface topography does not
for a convenient tailrace outlet. interfere at all.
4. Possibility of elimination of surge tank required 4. There is greater freedom in positioning stations.
for surface station due to long pressure channel. 5. Maintenance cost of power station including
5. The rugged topographical features and the painting, heating etc. are practically eliminated.
difficulties in finding a suitable short and steep 6. These stations are safer from defence point of
slope for pipe lines make it more economical to view and are immune to bombardment. They are
install the water conduit, the machine, also protected against such natural hazards as
transformer hall and tailrace system rain, wind, loose rocks etc.
underground. 7. There is saving in cost of land.
Types of layouts for underground hydro-plant 8. Land acquisition problem is minimum.
The following are two distinctly different types of 9. There is greater uniformity in climatic conditions
layouts for underground hydro-power stations : during all seasons.
(i) The head development 10. In steep and rugged countryside, the site
selection for an outdoor plant may cause
(ii) The tail development.
difficulties due to the risk of avalanches and land
In the head development the powerhouse is located slips. At some places there might be added
at the intake and provides a long unlined tailrace tunnel. hazard due to forest fire.
The necessity of surge shafts and penstocks is eliminated 11. Uninterrupted construction work in adverse
and quicker opening and closing of the turbine is possible. weather.
The same crew can operate the power house and headworks
12. Shorter conduit lengths and therefore smaller
which gives an operational advantage.
surge tanks.
HYDRO-ELECTRIC POWER PLANT 361
13. A tailrace tunnel may be easier to design and The float switch works with the change in level of
construct compared to the headrace pressure water in the reservoir, so that if the water level rises the
tunnel. generator output is increased and vice versa. Thus the
14. The useful life of the structures excavated in the station shares the load in interconnected system according
rock is considerably longer than that of concrete to availability of water in the reservoir.
and reinforced concrete structures. The load sensitive device is actuated by the demand
15. It is possible to improve the governing of the for power in the area served by the plant, so that increase
turbines with the construction of underground in power demand would increase the output of the
power station. generators automatically. In case of any trouble arising
16. The construction period is reduced mainly due anywhere in the system, the plant is automatically shut-
to the possibility of full-scale construction work down till such time as the source of trouble is removed.
in winter. 2. Partly automatic plant. In partly automatic
17. At places, where there is extreme difference in system the units are manually started and synchronised,
climate of winter and summer, a uniform but in case of a fault shutdown automatically. The partly
temperature can be maintained inside the plant automatic system is cheaper than fully automatic control
with adequate control of ventilation regardless system.
of outside weather. 3. Remote control plant. When the control on a
Disadvantages : power system is exercised from a distance, usually from
another generating station or control centre, the automatic
1. The cost of construction of power station and
control system becomes a remote controlled one. In such a
accessories is more.
system the operator at the control point transmits a signal
2. Increased cost of lighting, special ventilation and to the controlled station and this actuates the automatic
air conditioning. system at the station to perform the desired effect such as
3. The tailrace tunnels and additional surge starting and stopping of the units and load distribution
chambers are costly. among the sets in operation. The automatic remote control
4. Additional cost of underground location of system also receives from the controlled stations all
transformers etc. necessary information such as water level in the reservoir,
share of load supplied by each unit etc.
6.17. AUTOMATIC AND REMOTE Small hydro-plants which are not justified to be
CONTROL OF HYDRO-STATION developed for manual control, can usually be justified by
the application of remote automatic control.
Some automatic controlling devices such as relays,
governors, voltage regulators etc. are employed in every 6.18. SAFETY MEASURES IN HYDRO-
hydro-station, big or small. However, a few operations may
still be needed to start or stop the units and distribute load
ELECTRIC POWER PLANTS
on two or more units in operation at a time. For stations Following safety measures need to be taken for the safe
where full shift operation is not required, the services of operation of an hydro-electric power plant :
the operators are not fully utilized. A saving in working 1. Surge tanks 2. Screens
cost of plant can be effected if the functions of the operators
are derived from an automatic control system. 3. Sand traps 4. Jet dispersers
An automatic system is more safe, efficient and 5. Pressure regulator.
reliable and usually works through the governor and the Surge tanks. A surge tank is used to prevent
voltage regulator. Due to these reasons automatic hydro- sudden increase of pressure in the supply line or the
stations have been developed. Automatic plants may be penstock. It is placed as near as possible to the turbine.
divided into following three classes : The tank may be open at the top or closed. In case it is
1. Fully automatic plant open at the top, it must not be lower than the level of the
2. Partly automatic plant water in the reservoir.
3. Remote controlled plant. Screens. These are provided to prevent logs, fishes,
1. Fully automatic plant. This type of plant may ice blocks and other obstructive elements from entering
be controlled by : the pipe lines and turbines.
(i) A time switch (ii) A float switch Sand traps. Sand traps are provided to prevent the
(iii) A load sensitive device. sand flowing with water in pipes since sand blast action of
The time switch may start and stop the power station solid matter in the water causes rapid wear of nozzles,
at preset clock timings. spears, blades etc. of the turbine.
362 POWER PLANT ENGINEERING
Jet dispersers. The discharged water at the bottom 6.20. CALCULATION OF AVAILABLE
of the high dams possesses large amount of energy which
is likely to cause scouring of the channel below the dam
HYDRO-POWER
and consequent damage to the dam foundation unless some The theoretical power available from falling water can be
means are provided to dissipate it. The possible remedies calculated using the following formula :
for this are either to discharge water into a cushion pool or
to provide a jet dispersers at the end of outlet pipe so that wQH
Pth = kW ...(6.29)
the end of the outlet pipe is such that the jet is broken up 1000
into a conical shower of drops and their energy is absorbed where, Pth = Theoretical output in kW,
by air. w = Weight density of water in N/m3,
Pressure regulator. It is usually operated by a Q = Flow through turbine (or quantity of water
governor of the turbine. It is provided on the pipeline near available for hydro-power generation) in
the turbine inlet so that when the turbine gates are m3/s, and
suddenly closed, pressure surges so produced are kept H = Head available in metres.
within the safe limits of the pipeline. The water discharged
The actual useful or effective output depends upon
from the regulator is passed on to tailrace through a
the efficiency of the various parts of the installation.
separate pipeline.
If 1 = Efficiency of pipelines, intake etc., and
6.19. PREVENTIVE MAINTENANCE OF 2 = Efficiency of hydraulic turbine,
HYDRO-PLANT Then overall efficiency o = 1 × 2.
Since the turbine and the generator are directly
The purpose of preventive maintenance is to minimise
coupled on common shaft the hydro-electrical power
breakdown and excessive depreciation resulting from
available will be given by the equation :
neglect. In a hydro-plant (using reaction turbines) monthly,
quarterly, half yearly and yearly inspection and Pactual = Pth × o ...(6.30)
maintenance are carried out on the following parts : wQH
Inspection/ Parts or Pactual = × o kW ...(6.31)
1000
Maintenance
Monthly Turbine cover parts (e.g. leakage unit, 6.21. COST OF HYDRO-POWER
drainage holes, servomotor connections,
turbine shaft and cover, oil pump etc.) The initial cost of any hydro-plant is very high but the
power produced by it is the cheapest. The following costs
Operating ring of turbines
are included in development of a hydro-plant :
Guide vane mechanism
1. Cost of land and riparian rights
Quarterly Servomotor
2. Cost of railways and highway required for the
Governor oil system
construction work
Ejector cabinet
Feedback system 3. Cost of construction
Half yearly Governor mechanism 4. Cost of engineering supervision of the project
Gauges 5. Cost of building etc.
Grease pumps for guide vanes and guide 6. Cost of equipment
bearings 7. Cost of equipment used for power transmission.
Grease pipes connected to grease pumps
Yearly Turbine auxiliaries (e.g. oil pressure 6.22. HYDROLOGY
tank, turbine guide bearing, turbine
instruments) 6.22.1. Introduction
Scroll casing runner with guide vanes
Hydrology may be defined as the science which deals with
Emergency slide valve the depletion and replenishment of water resources. It deals
Pit liner with the surface water as well as the ground water. It is
Draft tube also concerned with the transportation of water from one
Runner blades checked for cavitational place to another, and from one form to another. It helps us
effects, cracks and wearing out. in determining the occurrence and availability of water.
HYDRO-ELECTRIC POWER PLANT 363
Hydrology aims at answering the following major Run-off can, therefore, also be named as Discharge
questions : or Stream flow. Rainfall duration, its intensity and a real
(i) How is the water going to precipitate ? distribution influence the rate and volume of run-off.
(ii) How is water going to behave ? Evaporation. Transfer of water from liquid to
vapour state is called evaporation.
(iii) What will happen to water after precipitation ?
Transpiration. The process by which water is
The basic knowledge of this science is a must for released to the atmosphere by the plants is called
every civil engineer, particularly the one who is engaged transpiration.
in the design, planning or construction of irrigation
structures, bridges and highway culverts, or flood control 6.22.3. Measurement of Run-off
works, etc. Run-off can be measured daily, monthly, seasonal or yearly.
6.22.2. The Hydrologic Cycle It can be measured by the following methods :
1. From rainfall records.
Most of the earth’s water sources, such as rivers, lakes,
oceans and underground sources, etc. get their supplies 2. Empirical formulae.
from rains, while the rain water itself is the evaporation 3. Run-off curves and tables.
from these sources. Water is lost to the atmosphere as 4. Discharge observation method.
vapour from earth, which is then precipitated back in the
1. From rainfall records. In this method
form of rain, snow, hail, dew, sleet or frost, etc. This
consistent rainfall record for a sufficiently long period is
evaporation and precipitation continues for ever, and
taken and then average depth of rainfall over the catchment
thereby, a balance is maintained between the two. This
is determined. Then considering all the factors which affect
process is known as Hydrologic Cycle. It can be represented
run-off process, a coefficient is arrived at for that catchment.
graphically as shown in Fig. 6.46. Hydrologic equation is
Now a simple equation can be used to find out the run-off
expressed as follows :
over the catchment.
P=R+E ...(6.32)
Run-off = Rainfall × coefficient ...(6.33)
2. Empirical formulae. In this method an attempt
Precipitation or is made to derive a direct relationship between the rainfall
SUN
(Rain, Snow, Hail, Sleet etc.) and subsequent run-off. For this purpose some constants
Transpiration Evaporation are established which give fairly accurate result for a
Sn from vegetations specified region. Some important formulae are given below:
ow
etc (a) Khosla’s formula :
. R = P – 4.811 T
Evaporation
W.T. where, R = Annual run-off in mm,
Ocean P = Annual rainfall in mm, and
Pe
rco T = Mean temperature in °C.
lat
ion (b) Inglis formulae for hilly and plain areas of
Maharashtra :
Fig. 6.46. Hydrologic cycle. For Ghat region
where, P = Precipitation, R = 0.88 P – 304.8
R = Run-off, and For plain region
E = Evaporation. ( P 177.8) P
R=
Precipitation. It includes all the water that falls 2540
from atmosphere to earth surface. Precipitation is of two (c) Lacey’s formula :
types : (i) Liquid precipitation (rain fall), (ii) Solid
P
precipitation (snow, hail). R=
3084 F
Run-off and surface run-off. Run-off and surface 1
PS
run-off are two different terms and should not be confused.
Run-off includes all the water flowing in the stream channel where, R = Monsoon run-off in mm,
at any given section. While the surface run-off includes P = Monsoon rainfall in mm,
only the water that reaches the stream channel without S = Catchment area factor, and
first percolating down to the water table.
F = Monsoon duration factor.
364 POWER PLANT ENGINEERING
Values of S for various types of catchment are given Hydrograph of stream of river will depend on the
below : characteristics of the catchment and precipitation over the
Type of catchment Value of S catchment. Hydrograph will access the flood flow of rivers
hence it is essential that anticipated hydrograph could be
Flat, cultivated and black cotton soils 0.25
drawn for river for a given storm.
Flat, partly cultivated, various soils 0.6
Hydrograph indicates the power available from the
Average catchment 1.00 stream at different times of day, week or year.
Hills and places with little cultivation 1.70 Typical hydrographs are shown in Figs. 6.47 and 6.48.
Very hilly and steep, with hardly any 3.45
cultivation
Values of F for various durations of monsoon are
given below : C
Class of monsoon Value of F
Discharge
Accession Recession
Very short 0.50
side side
Standard length 1.00
Very long 1.50 A B
D
3. Run-off curves and tables. Each region has its E
own catchment area and rainfall characteristics. Thus
formulae given above and coefficients derived there in
Aug.
Sept.
Oct.
Nov.
Dec.
Jan.
Feb.
Mar.
April
April
June
May
July
cannot be applied universally. However, for the same region
the characteristics mostly remain unchanged. Based on this Time
fact the run-off coefficients are derived once for all. Then a
graph is plotted in which one axis represents rainfall and Fig. 6.47. Typical hydrograph.
the other run-off. The curves obtained are called run-off
curves. Alternatively a table can be prepared to give the
run-off for a certain value of rainfall for a particular region. Peak flow
4. Discharge observation method. By actual
Discharge in the river
Storm
rainfall Run-off hydrograph
Surface Run-off (m3/sec.)
Discharge (m3/sec.)
Flow duration
curve
Peak
flow
Unit
hydrograph 0 10 20 30 40 50 60 70 80 90 100
Time (%)
Run-off time (Hours)
Fig. 6.50. Flow duration curve.
Fig. 6.49
366 POWER PLANT ENGINEERING
If the head of discharge is known, the possible power Shortcomings/Defects of Flow Duration Curve
developed from water in kW can be determined from the 1. It does not present the flows in natural source of
following equation : occurrence.
wQH 2. It is also not possible to tell from flow duration
Power (kW) = × o
1000 curve whether the lowest flows occurred in consecutive
3
where, Q = Discharge, m /sec., periods or were scattered throughout the considered period.
H = Head available, m, 6.22.6. Mass Curve
w = Weight density of water, N/m3, and
A ‘mass curve’ is the graph of the cumulative values of
o = Overall efficiency. water quantity (run-off) against time. A mass curve
Thus the flow duration curve can be converted to a (Fig. 6.51) is an integral curve of the hydrograph which
power duration with some other scale on the same graph. expresses the area under the hydrograph from one time to
Flow duration curves are most useful in the another.
following cases :
(i) For preliminary studies
(ii) For comparison between streams.
Uses of flow duration curve
1. A flow duration curve allows the evaluation of
low level flows.
2. It is highly useful in the planning and design of Cumulative discharge
water resources projects. In particular, for hydro-power
studies, the flow duration curve serves to determine the
potential for firm power generation. In the case of a run-
of-the-river plant, with no storage facilities, the firm power
is usually computed on the basis of flow available 90 to
97% of the time. The firm power is also known as the
primary power. Secondary power is the power generated
at the plant utilising water other than that used for the
generation of firm power.
3. If a sediment rating curve is available for the given
stream, the flow duration curve can be converted into
Time
cumulative sediment transport curve by multiplying each
flow rate by its rate of sediment transport. The area under Fig. 6.51. Mass curve.
this curve represents the total amount of sediment
transported. It is a convenient device to determine storage
4. The flow duration curve also finds use in the requirement that is needed to produce a certain dependable
design of drainage systems and in flood control studies. flow from fluctuating discharge of a river by a reservoir.
5. A flow duration curve plotted on a log-log paper Mass curve can also be used to solve the reserve
provides a qualitative description of the run-off variability problem of determining the maximum demand rate that
in the stream. If the curve is having steep slope throughout, can be maintained by a given storage volume. However, it
it indicates a stream with highly variable discharge. This is a trial and error procedure.
is typical of the conditions where the flow is mainly from The mass curve will always have a positive shape
surface run-off. A flat slope indicates small variability but of a greater or less degree depending upon the
which is a characteristic of the streams receiving both variations in the quantity of inflow water available. The
surface run-off and ground water run-off. A flat portion at negative inclination of mass curve would show that the
the lower end of the curve indicates substantial contribution amount of water flowing in the reservoir was less than the
from ground water run-off, while the flat portion at the loss due to evaporation and seepage.
upper end of the curve is characteristic of streams with
large flood plain storage, such as lakes and swaps, or where 6.23. HYDRO-POWER DEVELOPMENT IN
the high flows are mainly derived from snowmelt. INDIA
6. The shape of the flow duration curve may change
with the length of record. This aspect of the flow duration Hydro-power is a renewable source of energy which entails
curve can be utilised for extrapolation of short records. many intrinsic advantages. In India the scope of water
power development is tremendous. The first hydro-power
HYDRO-ELECTRIC POWER PLANT 367
station in India dates back to year 1897 when a small power Kerala
station of 200 kW capacity was constructed at Darjeeling. Parambikulam-Aliyar 185
Since then many big and small hydro-power stations have Sabarigiri 300
been installed in the country. Total hydro-potential in our
Idikki (Stage I) 390
country is estimated to be equivalent to about 75000 MW
at 60 per cent load factor of which only 12 to 14 per cent Maharashtra
has been exploited so far. Koyna (stages I, II and III) 860
Manipur
Important hydro-plants in India
Loktak 70
State/Name of Installed Odisha
power plant capacity (MW) Hirakud (stages I and II) 270
Andhra Pradesh Balimela 480
Machkand (stage I and II) 114 Punjab
Upper silern 120 Bhakra Nangal 1084
Lower silern 600 Beas-Sutlej link 780
Srisailam 770 Rajasthan
Nagarjun sagar pumped storage 100 Chambal 287
Assam Uttar Pradesh
Umiam 54 Rihand 300
Gujarat Yamuna (stage I and II) 424
Ukai 300 Tamil Nadu
Himachal Pradesh Kundah (stages I, II and III) 425
Baira suil 200 Kodiar 100
Jammu and Kashmir Although the present utilization of hydro-power in
Salal 270 over country is relatively small with the present tempo of
Karnataka development and need for power resources it would not be
long before the available potential is fully harnessed.
Tungabhadra 72
Hydro-field provides immense scope for sophisticated study
Sharavati 890 requiring application of modern mathematical and
Kailindi 396 operational research techniques with the help of computers.
WORKED EXAMPLES
Penstock pd 2.06 2.4
or, t=
Example 6.1. A penstock is working under a water head of 2 f 2 105 0.82
210 metres. Its diameter is 2.4 metres. Find its thickness if = 0.0287 m or 28.7 mm
the joint efficiency is 82 per cent and allowable stress in the Hence thickness of the penstock = 28.7 mm. (Ans.)
material is 105 MN/m2.
Solution. Working head, H = 210 m Hydraulic Turbines
Diameter of the penstock, d = 2.4 m Example 6.2. A Pelton wheel is receiving water from a
Efficiency of the joint, = 82% penstock with a gross head of 510 m. One-third of gross
head is lost in friction in the penstock. The rate of flow
Allowable stress in the material, f = 105 MN/m2 through the nozzle fitted at the end of the penstock is
Thickness, t : 2.2 m3/sec. The angle of deflection of the jet is 165°.
Pressure, p = wH Determine:
(w = weight density of water = 9810 N/m3) (i) The horse power given by the water to the runner
9810 210 (ii) Hydraulic efficiency of the Pelton wheel.
i.e., p= = 2.06 MN/m2
106 Take Cv (co-efficient of velocity = 1.0) and speed ratio
Using the relation = 0.45.
pd Solution. Gross head, Hg = 510 m
f= Hg
2t 510
Head lost in friction, hf = = 170 m
3 3
368 POWER PLANT ENGINEERING
Net head, H = Hg – hf = 510 – 170 = 340 m (ii) Hydraulic efficiency of the turbine,
Discharge, Q = 2.2 m3/s 2(Cw1 Cw2 ) Cbl 2(81.67 6.64) 36.75
h
Angle of deflection = 165° C12 (81.67)2
Angle = 180 – 165° = 15° = 0.973 or 97.3%. (Ans.)
Coefficient of velocity, Cv = 1.0 Example 6.3. A Pelton wheel is to be designed for the
Speed ratio = 0.45 following specifications :
Power 9650 kW
Cbl Cw Head 350 metres
2 2
f Speed 750 r.p.m.
b
Outlet
C2 Cf Overall efficiency 85%
triangle 2
Cr
2 Jet diameter not to exceed 61 th of the
wheel diameter
Cbl Cr Determine the following :
1 1 165°
(i) The wheel diameter,
C1 = C w
1 Bucket/vane (ii) Diameter of the jet,
(iii) The number of jets required.
Take Cv = 0.985, speed ratio = 0.45.
Fig. 6.52 Solution. Shaft or brake power,
= 9650 kW
Velocity of jet, C1 = Cv 2 gH
Head, H = 350 m
= 1.0 2 9.81 340 Speed, N = 750 r.p.m.
Overall efficiency,
= 81.67 m/s
o = 85%
Velocity of wheel, d
Ratio of jet dia. to wheel dia. = = 1/6
Cbl = Speed ratio × 2 gH D
Cbl = Cbl1 Cbl2 Coefficient of velocity,
Cv = 0.985
= 0.45 × 2 9.81 340 Speed ratio = 0.45
= 36.75 m/s (i) Wheel diameter, D :
Cr1 = C1 – Cbl1 Velocity of jet, C1 = Cv 2 gH
= 81.67 – 36.75 = 44.92 m/s = 0.985 2 9.81 350
Also, Cw1 = C1 = 81.67 m/s = 81.62 m/s
From outlet velocity triangle, we have The velocity of wheel,
Cbl = Cbl Cbl
Cr Cr = 44.92 m/s
2 1
1 2
= Speed ratio × 2 gH
Also, Cr2 cos = Cbl2 Cw2
= 0.45 × 2 9.81 350
44.92 cos 15° = 36.75 + Cw2
= 37.3 m/s
or Cw2 = 44.92 cos 15° – 36.75 DN
But Cbl =
= 6.64 m/s 60
Work done by the jet on the runner per second is D 750
or 37.3 =
given by the equation 60
= Q (Cw Cw ) × Cbl 37.3 60
1 2 D= = 0.95 m. (Ans.)
= 1000 × 2.2 (81.67 + 6.64) × 36.75 750
= 7139863 Nm/s (ii) Diameter of the jet, d :
(i) Power given by the water to the runner d
= 1/6 (Given)
= 7139863 J/s or D
d = 1/6D = 1/6 × 0.95
W~ 7139.8 kW. (Ans.) = 0.158 m. (Ans.)
HYDRO-ELECTRIC POWER PLANT 369
Discharge p2
(i) Pressure head at inlet, :
w
Q= × 32 × 9.43 = 66.65 m3/s
4 Discharge through the draft tube,
Overall efficiency,
Power developed 2850 Q = A3V3 = × d02 × V3
4
o =
Water power wQH
=× 1.82 × 3 = 7.634 m/s
2850 4
= Velocity of inlet,
9.81 66.65 5.2
= 0.8382 or 83.82%. (Ans.) Q 7.634 7.634
V2 = = 6.75 m/s
Example 6.9. A conical draft tube having inlet and outlet A2 2
di 1.22
diameters 1.2 m and 1.8 m discharges water at outlet with 4 4
a velocity of 3 m/s. The total length of the draft tube is 7.2 m Using eqn. (6.10)
and 1.44 m of the length of draft tube is immersed in water.
p2 p ⎛ V 2 V32 ⎞
If the atmospheric pressure head is 10.3 m of water and = a Hs ⎜ 2 hf ⎟
loss of head due to friction in the draft tube is equal to 0.2 × w w ⎜ 2g ⎟
⎝ ⎠
velocity head at outlet of the tube, determine :
pa ⎛ V 2 V32 V 2⎞
(i) Pressure head at inlet, and = Hs ⎜ 2 0.2 3 ⎟
w ⎜ 2g 2 g ⎟⎠
(ii) Efficiency of the draft tube. ⎝
Solution. Inlet diameter of the draft tube, F 6.75 3
2 2
32 I
di = 1.2 m = 10.3 – 5.76 – GH 2 9.81 0.2
2 9.81 JK
Outlet diameter,
p2
d0 = 1.8 m or = 4.54 – (1.863 – 0.092)
w
Velocity at outlet = 2.769 m (abs). (Ans.)
V3 = 3 m/s
(ii) Efficiency of the draft tube, d :
Total length of draft tube,
Hs + y = 7.2 m ⎛ V22 V32 ⎞ V22 V32 V32
⎜⎜ hf ⎟ 0.2
Length of draft tube in water, 2g ⎟ 2g 2g
d = ⎝ ⎠ =
y = 1.44 m V2 2 V22
Hs = 7.2 – 1.44 = 5.76 m 2g 2g
Atmospheric pressure head,
pa V22 ⎛ V32 V 2⎞
= 10.3 m ⎜ 0.2 3 ⎟
w 2 g ⎜⎝ 2 g 2 g ⎟⎠
Loss of head due to friction, =
V22
hf = 0.2 × velocity head at outlet
2g
V32
= 0.2
2g FV I
= 1 – 1.2 G J
2
F 3 IJ
= 1 – 1.2 G
2
H 6.75 K
3
di
Inlet of draft tube HV K
2
2000 150 P
Pelton wheel 460 =
(18)5 / 4
500
Francis turbine (where P is in kW and H is in metres)
or Power available at turbine shaft,
Head (m)
100
L 460 (18) OP
5/ 4 2
P= M
1 jet Kaplan turbine
20
2 jets
3 jets
MN 150 PQ = 12927.5 kW
Speed, N = 450 r.p.m. Example 6.16. The quantity of water available for hydro-
P electric station is 250 m3/sec. under a head of 1.6 m. If the
Now, = speed of the turbine is 50 r.p.m. and efficiency 82% determine
wQH
the number of turbine units required. Take specific speed
Power developed, as 740.
P = × wQH Solution. Quantity of water available,
= 0.82 × 9.81 × 0.24 × 45 = 86.88 kW Q = 250 m3/s
Specific speed, Head, H = 1.6 m
N P 450 86.88 Speed, N = 50 r.p.m.
Ns =
H 5/4 (45)5/4 Efficiency, = 82%
3.6 r.p.m. (Ans.) Specific speed, Ns = 740
For this specific speed Pelton turbine is suitable. Number of turbine units required :
(Ans.) Total power (Ptotal) to be developed can be calculated
Example 6.15. A hydro-electric power station is desired to using the following equation,
be built across a river having a discharge of 28000 litres/s Ptotal = wQH
at a head of 11 m. Assuming turbine efficiency 78% and = 0.82 × 9.81 × 250 × 1.6
speed ratio as 0.82, determine : = 3217.7 kW
(i) Can we use two turbines with a speed not less The power developed by each turbine can be
than 120 r.p.m. and specific speed more than 350 r.p.m. ? calculated be using the following equation :
(ii) Specify the type of turbine/runner that can be
N P
used. Also calculate the runner diameter. Ns =
Solution. Discharge, H 5/ 4
FG 28000 IJ 740 =
50 P
Q = 28000 litres/sec.
H 1000
28 m3 /s
K (1.6)5 / 4
Turbine efficiency, = 78% 740 (1.6)5 / 4
P
Speed ratio = 0.82 50
Head, H = 11 m L 740 (1.6) OP
P= M
5/4 2
P1
L 260 (28) OP
= M
5/ 4 2
= 4487 kW
and
H1
H2
...[Eqn. (6.20)]
MN 250 PQ Q2 =
Q1 H2
9 20
Number of Francis turbines required H1 25
P 77954.2 = 8.05 m3/s (Ans.)
= = 17.4 18. (Ans.)
P1 4487 P1 P2
and ...[Eqn. (6.21)]
(ii) The power capacity of each Kaplan turbine can H13/2
( H2 )3 / 2
be calculated by using the following formula :
P1 ( H2 )3 / 2 1986.5 (20)3 / 2
N P1 P2 =
Ns = ( H1)3 / 2 (25)3 / 2
H 5/ 4 = 1421.4 kW. (Ans.)
250 P2 Example 6.19. A hydro-turbine is required to give 25 MW
770 =
(28)5 / 4 at 50 m head and 90 r.p.m. runner speed. The laboratory
P2
L 700 (28)
= M
OP
5/ 4 2
= 32524.5 kW
facilities available, permit testing of 20 kW model at 5 m
head. What should be the model runner speed and model
MN 250 PQ to prototype scale ratio? (GATE)
Number of Kaplan turbines required Solution. Given : Pp = 25 MW ; Hp = 50 m ; Np = 90 r.p.m.;
Pm = 20 kW ; Hm = 5 m
P 77954.2
= 2.4 3. (Ans.) Dp
P2 32524.5 Nm ; (= Lr) :
Example 6.18. A turbine is to operate under a head of 25 m Dm
at 200 r.p.m. The discharge is 9 m3/s. If the efficiency is Prototype specific speed,
90 per cent determine the performance of turbine under a N p Pp
head of 20 m. (M.U.) (Ns)p = (where P is in kW)
( H p )5 / 4
Solution. Head under which turbine works,
H1 = 25 m 90 25 103
= = 107
Speed of the turbine, (50)5 / 4
For model,
N1 = 200 r.p.m.
Nm Pm
Discharge through the turbine, 107 = [∵ ( N s ) p ( N s ) m ]
( Hm ) 5 / 4
Q1 = 9 m3 /s
107 ( Hm )5 / 4 107 (5)5 / 4
Efficiency (overall), or Nm =
Pm 20
o = 90%
= 178.89 r.p.m. (Ans.)
HYDRO-ELECTRIC POWER PLANT 377
H N JK GH D JK
or p p Head under which model is tested,
Pm m m Hm = 7.2 m (Given)
F 8I
= (1) × G J = 8
5 Nm , Pm, Qm :
H 1K
3 5 (∵ Np = Nm) For similar turbines each of the following parameters
must be same for both model and prototype.
Pp 10 106
Pm = = 305.2 W. (Ans.) H
(8) 5
(8)5 (i) Head co-efficient, CH = ;
N 2 D2
(ii) Ratio of heads and ratio of mass flow Q
(ii) Flow co-efficient, CQ =
ND3
P
rates : (iii) Power co-efficient, Cp = 3 5
N D
We know that H N 2 D2 ...[Eq. (6.22)] FG H IJ FG H IJ Hm Hp
Hp F N I F D I 2 2
(i)
H 2 2
N D m K H 2 2
N D p K or 2
Nm Dm 2
N p2 Dp2
Hm
= GH N JK GH D JK
p
m
p
m or Nm2 = Np2
D p2
Hm
= ×(1)2= 64. (Ans.) (8)2 Dm2 Hp
Also, Discharge, Q ND3 ...[Eqn. (6.23)] FH I
Dp
G
1/2
H H JK
m
Ratio of mass flow rates, Model speed, Nm =N × p
D
Qp mp FN IFD I
G
3 m p
H N JK GH D JK F 7.2 IJ
p p
1/2
= 120 × 10 × G
Qm mm m m
= 1 × (8)3 = 512. (Ans.)
H 12 K
= 929.5 r.p.m. (Ans.)
378 POWER PLANT ENGINEERING
FG Q IJ FG Q IJ Qm Qp 120f 120 f
(ii)
H ND K H ND K
3
m
3
p
or
Nm Dm3
N p Dp3
Again, N=
p
or p =
N
Discharge in the model, (where p = Number of poles)
120 50
F I
Nm Dm
3 p= = 8.07 8 (say)
Qm = Qp × GH JK
Np
Dp Corrected speed
743.3
929.5 F 1 I
3 120 f 120 50
G J =
= 9.372 ×
120 H 10 K p 8
= 750 r.p.m. (Ans.)
= 0.0726 m3/s. (Ans.)
Example 6.23. A flow of 75 m3/s under a head of 110 m is
FG P IJ FG P IJ Pm Pp available at a site for a hydro-power station. If the efficiency
(iii)
HN D K HN D K
3 5
m
3 5
p
or 3
Nm Dm5
N p3 Dp5 of the turbine is 88% and generator efficiency is 92%,
Power produced by the model, determine :
(i) Power developed,
FN I FD I 3 5
Pm = Pp × GH N JK GH D JK
m
p
m
p
(ii) Number of units required and their capacities.
Solution. Discharge, Q = 75 m3/s
= 1015 × G
F 929.5 IJ FG 1 IJ 3 5 Head, H = 110 m
H 120 K H 10 K Turbine efficiency, t = 88%
Generator efficiency, g = 92%
= 4.72 kW. (Ans.)
(i) Power developed, P :
Hydro-electric Power Station P = t × wQH
Example 6.22. The following data relate to a hydro-electric or P = 0.88 × 9.81 × 75 × 110
power station : = 71220 kW. (Ans.)
Head = 400 m ; Discharge = 4.5 m3/s ; Turbine 71220
efficiency = 8.2% ; Generator frequency = 50 Hz. Determine: (ii) Two turbines each of = 35610 kW
2
(i) Power developed, (ii) Type of the turbine, capacity may be used. (Ans.)
(iii) Speed of the turbine. Generator capacity of each unit
Solution. Head, H = 400 m = g × 35610
Discharge, Q = 4.5 m3/s = 0.92 × 35610 = 32761 kW
Turbine efficiency, = 82% Total power generated by the generators
Generator frequency, f = 50 Hz = 32761 × 2
(i) Power developed, P : = 65522 kW or 65.5 MW. (Ans.)
P = × wQH Example 6.24. A proposed hydro-electric station has an
available head of 120 metres, a catchment area of
= 0.82 × 9.81 × 4.5 × 400
200 sq. km, the rainfall of which is 120 cm per annum. If
= 14479 kW. (Ans.) 62% of the total rainfall can be collected, calculate the power
(ii) Type of turbine : that could be generated. Suggest suitable ratings of
Pelton turbine should be used for a head of 400 m. generators.
(Ans.) Solution. Available head, H = 120 m
(iii) Speed of the turbine, N : Catchment area,
N = Actual speed of the turbine A = 200 sq. km (= 200 × 106 m2)
Ns = Specific speed of the turbine. Rainfall = 120 cm per annum (= 1.2 m)
Rainfall collected/annum,
Choosing an approximate speed of about 50.
h = 62% of the total rainfall
N P = (0.62 × 1.2) m.
Also, Ns =
H 5/4 Power developed, P :
N s ( H )5 / 4 50 (400)5 / 4 Total quantity of water available for power
N= =
P 14479 generation
= 743.3 r.p.m. = A × h = 200 × 106 × (0.62 × 1.2)
= 148.8 × 106 m3/year
HYDRO-ELECTRIC POWER PLANT 379
Example 6.27. From the investigation of a hydro-site the (i) Type of turbine :
following data is available : P = o × wQH
Available head 45 m 20 × 103 = 0.72 × 9.81 × Q × 15
Total catchment area 60 sq. km
20 103
Rainfall per annum 140 cm Q= = 188.8 m3/s
0.72 9.81 15
Percentage of rainfall utilized 68%
As the head is low and discharge is high so a
Turbine efficiency 82%
propeller type of turbine should be used. (Ans.)
Generator efficiency 90%
(ii) Synchronous speed of the generator, Nsyn :
Percentage efficiency 74%
1150
Calculate the suitable capacity of a turbo-generator. Specific speed, Ns = (approx.)
H 1/ 4
Solution. Head available, H = 45 m
1150
Catchment area, A = 60 sq. km = = 584.3 r.p.m.
(15)1/4
(= 60 × 106 m2)
Ns H 5 / 4 F∵ N N P I
Available rainfall,
Turbine efficiency,
h = (0.68 × 1.4) m
t = 82%
Speed of rotation, N =
P
GH s
H 5/ 4
JK
Generator efficiency, g = 90% 584.3 (15)5 / 4
Penstock efficiency, p = 74%
=
F 20 10 I3 1/2
Hydrology
Example 6.35. At a particular site the mean monthly
discharge is as follows :
The flow duration curve is then plotted as shown in The mean discharge for the given data
Fig. 6.59. 40 25 20 10 0 50 75
100 110 60 50 40
Note. When selecting a suitable site for a hydro-power =
plant the flow data for a number of years is collected and 12
hydrographs and flow duration curves and the various 580
periods are determined. = = 48.33 millions of m3/month.
12
Example 6.36. The runoff data of a river at a particular (ii) Flow duration curve :
site is tabulated below : To obtain the flow duration curve it is necessary to
find the lengths of time during which certain flows are
Month Mean discharge per month
available. This information is tabulated, using the
(millions of cu m)
hydrograph, in the table below :
January 40
February 25 Discharge Total number of Percentage
March 20 per month months during time
(millions of m3) which flow is
April 10
available
May 0
June 50 0 12 100
July 75 10 11 91.7
August 100 20 10 83.3
September 110 25 9 75
October 60 40 8 66.7
November 50 50 6 50
December 40 60 4 33.3
75 3 25.0
(i) Draw a hydrograph and find the mean flow,
100 2 16.7
(ii) Also draw the flow duration curve, 110 1 8.3
(iii) Find the power in MW available at mean flow if
the head available is 80 m and overall efficiency of The flow duration curve can be drawn using the data
generation is 85%. tabulated as shown in Fig. 6.61.
Take each month of 30 days.
Solution. (i) Hydrograph :
The hydrograph for the given data is drawn as
shown in Fig. 6.60.
130
120
110 110
110
100 100
Discharge (millions of cu. m) / month
90
80 Hydrograph
75
70
60
60
50 50 50 Mean flow
40 (48.33)
40 40
30
25
20 20
10 10
0
J F M A M J J A S O N D
Months
Fig. 6.61. Flow duration curve.
Fig. 6.60. Hydrograph.
HYDRO-ELECTRIC POWER PLANT 385
(iii) Average MW energy available : The energy used from the thermal plant to pump the
1 water of pump storage plant during off-peak period must
= o wQH × MW be equal to the energy supplied by the pump-storage plant
1000
(where w = 9.81 kN/m3) during peak period.
LMwhere Q (discharge in m /s) 48.33 10 OP
3
6 120
N 30 24 3600 Q 110
6
9.81 48.33 10 80 1 100
= 0.85 × MW Load curve
(30 24 3600) 1000 90
= 12.4 MW. (Ans.)
80
Example 6.37. The nature of load required for 24 hours
and thermal efficiencies of the plant at the respective loads 70
are given in the table below :
Load, MW
Base load
60 thermal plant
Time period Load Thermal efficiency 50
of 71.67 MW
capacity
(MW) (% age)
40
10 A.M. to 6 P.M. 120 32%
6 P.M. to 8 P.M. 60 24% 30
8 P.M. to 12 A.M. 30 15% 20
12 A.M. to 6 A.M. 15 10%
10
6 A.M. to 10 A.M. 75 25%
(i) Find the total input to the thermal plant if the 6 A.M. 12 P.M. 6 P.M. 12 A.M. 6 A.M.
load is supplied by the single thermal plant only. Time period
(ii) If the above load is taken by combined thermal Fig. 6.62. Load curve.
and pump storage plant, then find the percentage saving
in the input to the plant. Thermal efficiency at full load = From the Fig. 6.62, we have:
32%. [(x – 60) × 2 + (x – 30) × 4 + (x – 15) × 6] × 0.7544
(iii) The overall efficiencies in both cases. = (75 – x) × 4 + (120 – x) × 8
In pump storage plant, the pump and turbine are or [(2x – 120) + (4x – 120) + (6x – 90) ] × 0.7544
separate. The efficiency of pump is 82% and water turbine = (300 – 4x) + (960 – 8x)
is 92%. or (12x – 330) × 0.7544 = 1260 – 12x
Solution. The load curve, drawn as per the data given, is or 9.053x – 248.95 = 1260 – 12x
shown in Fig. 6.62.
1260 248.95
Total output per day x= = 71.67 MW
(9.053 12)
= 75 × 4 + 120 × 8 + 60 × 2 + 30 × 4 + 15 × 6
The energy supplied in the second case
= 300 + 960 + 120 + 120 + 90 = 1590 MWh
71.67 24
(i) Total input to the thermal plant : == 5375 MWh
0.32
The input to the thermal plant
The percentage saving in input if the load is taken
75 4 120 8 60 2 30 4 15 6 by combined thermal and pump storage plant.
=
0.25 0.32 0.24 0.15 0.1 6400 5375
= 1200 + 3000 + 500 + 800 + 900 =
6400
= 6400 MWh. (Ans.) = 0.16 or 16%. (Ans.)
(ii) Percentage saving in the input to plant : (iii) The overall efficiency in the first case
The overall efficiency of the pump storage plant 1590
= = 0.2484
= 0.82 × 0.92 6400
= 0.7544 or 75.44%. = 24.84%. (Ans.)
Assume that the capacity of the thermal plant is x The overall efficiency in the second case
MW when it is working in combination with pump-storage 1590
=
plant. 5375
= 0.2958 or 29.58%. (Ans.)
386 POWER PLANT ENGINEERING
3
July 1250 900
Aug. 1500 800
Sep. 1200 700
Oct. 1000 600
Nov. 750 500
Dec. 750
400
Jan. 500
300
Feb. 400
200
Mar. 300
100
(i) Draw hydrograph for the given discharges and
find the average monthly flow. 0 10 20 30 40 50 60 70 80 90 100
Percentage of time
(ii) Also draw the flow duration curve.
(iii) The power available at mean flow of water if Fig. 6.64. Flow duration curve.
available head is 90 metres at the site and overall efficiency
The average monthly flow (Refer to Fig. 6.63)
of the generation is 82 per cent.
250 100 750 1250 1500 1200
Take 30 days in a month.
1000 750 750 500 400 300
Solution. (i) Hydrograph : =
12
The hydrograph, drawn as per data given, is shown = 729.2 millions of m3/month.
in Fig. 6.63. (ii) Flow duration curve :
In order to obtain the flow duration curve it is
1600 necessary to find the lengths of time during which certain
flows are available.This information is tabulated, using the
hydrograph, in the following table :
1400
Hydrograph
Discharge Total number of Percentage
per month months during time during
Discharge, millions of m /month
1200
million of m3 which flow is which flow is
available available
3
1000
100 12 100
250 11 91.8
800
300 10 83.40
400 9 76.00
600
Mean flow 729.2 500 8 66.60
3
millions of m /month 750 7 58.40
400
1000 4 33.30
(iii) Power available at mean flow of water : Week Weekly flow Weekly flow in Cumulative
The mean/average flow available per second (a) in m3/s (b) day-sec-metre volume in day-
(c) = (b) × 7 sec-metres
729.2 106 (d)
= = 281.3 m3/s
30 24 3600
1 3000 21000 21000
Average kW available at the site 2 2000 14000 35000
wQH 3 2700 18900 53900
= ×g MW
1000 4 1000 7000 60900
(∵ w = g = 1000 × 9.81 = 9.81 kN/m3)
5 750 5250 66150
9.81 281.3 90 6 500 3500 69650
= × 0.82
1000 7 600 4200 73850
= 203.6 MW. (Ans.)
8 2250 15750 89600
Example 6.39. The data for a weekly flow at a particular
9 4000 28000 117600
site is given below for 12 weeks :
10 2000 14000 131600
Week Weekly flow, Week Weekly flow,
11 1500 10500 142100
m3/s m3/s
12 1000 7000 149100
1 3000 7 600
2 2000 8 2250 If the mean flow is available in the week at the
3 2700 9 4000 given rate, then the total flow in the week = 7 × day × m3/sec
4 1000 10 2000 = 7 × day-sec-metres.
5 750 11 1500 By using the above tabulated data, the mass curve
6 500 12 1000 can be drawn as shown in Fig. 6.65.
Draw the tangent at the highest point on the
With the help of mass curve, find the size of the
mass curve from ‘p’ and measure the highest
reservoir and the possible rate of available flow after the
distance between the tangent drawn and mass
reservoir has been built.
curve which gives the capacity of the reservoir.
Solution. In order to draw mass curve, we need to find the
In this capacity of the reservior = 18 × 103
cumulative volume of water that can be stored week after
day-sec-metres. (Ans.)
week. This is done as tabulated in the table.
The slope of the line ‘pq’ gives the flow rate
150 available for the given capacity reservoir.
140 Flow rate available
130 qr 54 103 (day - sec - metres)
= =
120 pr 5.5 7(days)
q
110 Storage capacity
= 1402.6 m3/s. (Ans.)
Flow in thousands of day-sec-metres
Solution. In order to draw the mass curve, we need to find the cumulative volume of water that can be stored month
after month. This is done as shown in the following table :
Month Flow per month (millions of m3) Cumulative volume, (millions of m3)
1 50 50
2 25 75
3 10 85
4 40 125
5 5 130
6 5 135
7 95 230
8 20 250
9 15 265
10 100 365
11 85 450
12 40 490
By using the above tabulated data, the mass curve can be drawn as shown in Fig. 6.66.
500
b
450
6 3
107.5 × 10 m
400 d
350
300
3
Millions of m
250
g
6 3
Spill = 36 × 10 m
200 f
6 3
35 × 10 m
150
e j
100
p
50 q r
c
a 1 2 3 4 5 6 7 8 9 10 11 12
Months
Fig. 6.66. Mass curve.
HYDRO-ELECTRIC POWER PLANT 389
(i) Required capacity for the uniform flow of (iii) Average flow capacity
25 millions m3 per month : Join points a and b, then the slope of the line ab
For finding the capacity of the reservoir for represents the uniform discharge throughout the
uniform flow of 25 millions m3 per month, year,
construct the pqr as shown in Fig. 6.66. qr
490
repersents one month and pr represents = × 106
25 millions m3. 12
Now draw the parallel lines to the line pq = 40.83 × 106 m3/month. (Ans.)
through the points e and g which are apex of Draw the line cd parallel to ab which touches
mass curve. The greatest departure of the mass the mass curve to its lowest point ‘j’. The
curve from these lines represents the storage maximum departure of the line cd from the mass
capacity. curve represents the required storage capacity
Storage capacity = 35 × 106 m3. (Ans.) for the uniform supply of 40.83 × 106 m3/month.
(ii) Spillway capacity : In this case, storage capacity required
Spillway capacity required (Fig. 6.66) = 107.5 × 106 m3. (Ans.)
= 36 × 103 m3. (Ans.)
HIGHLIGHTS
1. A dam is a barrier to confine or raise water for storage or 9. The modern Francis water turbine is an inward mixed
diversion to create a hydraulic head. flow reaction turbine. It operates under medium heads
2. A canal is an open waterway excavated in natural ground. and also requires medium quantity of water.
A flume is an open channel excavated on the surface or 10. In the propeller turbine the runner blades are fixed and
supported above ground on a trestle. A tunnel is a closed non-adjustable. In Kaplan turbine, which is a modification
channel excavated through a natural obstruction such as of propeller turbine the runner blades are adjustable and
a ridge of higher land between the dam and the can be rotated about the pivots fixed to the boss of the
powerhouse. runner.
3. A surge tank is a small reservoir or tank in which the 11. ‘Cavitation’ may be defined as the phenomenon which
water level rises or falls to reduce the pressure swings so manifests itself in the pitting of the metallic surfaces of
that they are not transmitted in full to a closed circuit. turbine parts because of formation of cavities.
4. A draft tube serves the following two purposes : 12. ‘Hydrology’ may be defined as the science which deals with
(i) It allows the turbine to be set above tail-water level, the depletion and replenishment of water resources.
without loss of head, to facilitate inspection and 13. Run-off includes all the water flowing in the stream
maintenance. channel at any given section. It can be measured by the
(ii) It regains, by diffuser action, the major portion of the following methods :
kinetic energy delivered to it from the runner. (i) From rainfall records
5. The plants which cater for the base load of the system are (ii) Empirical formulae
called ‘base load plants’ whereas the plants which can (iii) Run-off curves and tables
supply the power during peak loads are known as peak (iv) Discharge observation method.
load plants.
14. Hydrograph is defined as a graph showing discharge (run-
6. Microhydel plants (microstations) make use of off) of flowing water with respect to time for a specified
standardized bulb sets with unit output ranging from 100 time. It indicates the power available from the stream at
to 1000 kW working under heads between 1.5 to 10 metres. different times of day, week or year.
7. The specific speed of a turbine is defined as the speed of a 15. Flow duration curve represents the run-off data for the
geometrically similar turbine that would develop one given time. It is plotted between flow available during a
brake horse power under a head of one metre. period versus the fraction of time.
8. The Pelton turbine is a tangential flow impulse turbine. 16. Mass curve is the graph of the cumulative values of water
The pressure over the Pelton wheel is constant and equal quantity (run-off) against time. It is an integral curve of
to atmosphere, so that energy transfer occurs due to purely the hydrograph which expresses the area under the
impulse action. hydrograph from one time to another.
390 POWER PLANT ENGINEERING
THEORETICAL QUESTIONS
1. Give the application of hydro-electric plants. 19. With the help of a schematic diagram explain the working
2. Enumerate advantages and disadvantages of hydro- of the modern Francis turbine.
plants. 20. What is a Kaplan turbine ? How does it differ from a
3. Enumerate and explain briefly the factors which should propeller turbine ?
be considered while selecting the site for hydro-electric 21. What are tubular or bulb turbines ?
plant. 22. What do you mean by ‘specific speed’ of a turbine ?
4. Enumerate essential elements of hydro-electric power 23. What is cavitation ? How can it be avoided/checked ?
plant. 24. Describe briefly the methods of governing an impulse
5. What is a catchment area ? turbine ?
6. What is a reservoir ? 25. What points should be considered while selecting a right
7. What is a dam ? What are its various types ? type of turbine ?
8. Explain briefly any two of the following dams : 26. Enumerate the various controls which are provided in an
(i) Rockfill dams hydro-electric power plant.
(ii) Buttress dams 27. Explain the advantages of combined operation of hydro-
electric station and thermal station.
(iii) Timber dams.
28. Compare hydro and thermal power plants.
9. What is a spillway ? Explain any two types of spillways.
29. List the advantages and disadvantages of underground
10. What is the difference between canal, flume and tunnel ? power house/station.
11. What is a surge tank ? 30. What safety measures need to be taken for the safe
12. Explain with a neat diagram any one of the following surge operation of an hydro-electric plant ?
tanks : 31. What do you mean by ‘preventive maintenance’ of hydro-
(i) Inclined surge tank plant ?
(ii) Restricted orifice surge tank 32. Define hydrology.
(iii) Differential surge tank. 33. Draw and explain the hydrologic cycle.
13. What are the functions of a draft tube ? 34. Define run-off. How is it measured ?
14. How are hydro-electric power plants classified ? 35. List the factors which affect run-off.
15. Explain a high head power plant giving its layout clearly. 36. What is a hydrograph ?
16. Explain with a neat sketch a pumped storage plant. 37. What is a unit hydrograph ? What are the limitations to
17. What is the function of a hydraulic turbine ? How are the the use of unit hydrographs ?
turbines classified ? 38. What is a flow duration curve ?
18. Explain the working of a ‘Pelton turbine’ with the help of 39. What is a mass curve ?
a neat diagram. 40. Write a short note on hydropower development in India.
UNSOLVED EXAMPLES
1. A penstock is working under a water head of 200 metres. Take Cv (coefficient of velocity) = 0.985 and speed rated
Its diameter is 2.5 metres. Find its thickness if the = 0.45. [Ans. (i) 0.989 m, (ii) 2, (iii) 0.165 m]
efficiency of the joint is 80% and allowable stress in the 4. A Francis turbine with an overall efficiency of 75% is
material is 1100 kgf/cm2. [Ans. 2.8 cm] required to produce 203 H.P. It is working under a head
2. A Pelton wheel has a mean bucket speed of 10 metres per of 7.62 m. The peripheral velocity = 0.26 2gH and the
second with a jet of water flowing at the rate of 700 litres/
sec. under a head of 30 metres. The buckets deflect the jet radial velocity of flow at inlet is 0.96 2gH . The wheel
through an angle of 160°. Calculate : runs at 150 r.p.m. and the hydraulic losses in the turbine
are 22% of the available energy. Assuming radial
(i) The horse power (ii) Efficiency of the turbine
discharge, determine :
Assume coefficient of velocity as 0.98.
(i) The guide blade angle,
[Ans. (i) 254.12 H.P., (ii) h = 94.54%] (ii) The wheel vane angle at inlet,
3. A Pelton wheel is to be designed for the following (iii) Diameter of the wheel at the inlet, and
specifications : (iv) Width of the wheel at inlet.
Power = 16000 B.H.P. ; Head = 380 metres ; Speed = 750 [Ans. (i) 37° 37 (ii) 37° 44.4 (iii) 0.4047 m, (iv) 0.177 m]
r.p.m. ; Overall efficiency = 86% ; Jet diameter is not to
5. The following data is given for a Francis turbine. Net head
exceed one-sixth of the wheel diameter.
H = 60 m ; Speed N = 700 r.p.m. ; Shaft horse power = 400
Determine : (i) The wheel diameter, (ii) The number of H.P. ; o = 84% ; h = 93% ; Flow ratio = 0.20 ; breadth
jets required, and (iii) Diameter of the jet. ratio n = 0.1 ; Outer diameter of the runner = 2 × inner
HYDRO-ELECTRIC POWER PLANT 391
diameter of runner. The thickness of vanes occupy 5% of 14. At a particular hydro-electric power plant site, the
circumferential area of the runner, velocity of flow is discharge of water is 400 m3/sec and the head is 25 m.
constant at inlet and outlet and discharge is radial at The turbine efficiency is 88%. The generator is directly
outlet. Determine : coupled to the turbine having frequency of generation of
(i) Guide blade angles, 50 Hz, and number of poles as 24. Calculate the least
(ii) Runner vane angles at inlet and outlet, number of turbines required if,
(iii) Diameters of runner of inlet and outlet, and (i) A Francis turbine is used with a specific speed of 300,
(iv) Width of wheel at inlet. (ii) A Kaplan turbine is used with a specific speed of 750.
[Ans. (i) 13° 55.7 (ii) 41° 5.4 (iii) 34° 44.4 (iv) 5.4 cm] [Ans. (i) 26, (ii) 5]
6. A Kaplan turbine develops 33500 H.P. at an average head 15. A flow of 80 m3/sec. under a head of 120 m is available at
of 39 metres. Assuming a speed ratio of 2, flow ratio of a site for a hydro-power plant. If the turbine efficiency is
0.6, diameter of the boss equal to 0.35 times the diameter 90% and generator efficiency is 94% determine the
of the runner and an overall efficiency of 90%, calculate following :
the diameter, speed and specific speed of the turbine. (i) Power developed
[Ans. 0.875 m, 422.61 r.p.m., 7963.65 r.p.m.] (ii) Number of units required and their capacities.
7. A turbine develops 10000 H.P. under a head of 25 metres [Ans. (i) 115200 H.P. ; (ii) Two, 39.85 mW (each generator)]
at 135 r.p.m. Calculate the specific speed of the turbine 16. A proposed hydro-electric station has an available head
and state the type of the turbine. [Ans. 241.49, Francis] of 100 metres, a catchment area of 225 sq. km, the rainfall
8. A turbine is to operate under a head of 25 m at 200 r.p.m. of which is 140 cm per annum. If 60% of the total rainfall
The discharge is 9 m3/sec. If the efficiency is 90%, deter- can be collected, calculate the power that could be
mine : generated. Suggest suitable ratings of generators.
(i) Specific speed of the machine [Ans. 5880 kW, 3000 kW capacity]
(ii) Power generated, and 17. The following data is available for a hydro-power plant :
(iii) Type of turbine. Available head = 130 m ; catchment area = 2200 sq. km. ;
[Ans. (i) 185.89 r.p.m., (ii) 2700 H.P., (iii) Francis] annual average rainfall = 150 cm ; turbine efficiency
= 86% ; generator efficiency = 91% , percolation and
9. Calculate the specific speed of a turbine and suggest the evaporation losses = 18%.
type of turbine required for a river having a discharge of
250 litres/sec. with a available head of 50 metres. Assume Determine power developed in MW taking load factor as
efficiency of turbine as 80% and speed 450 r.p.m. unity. [Ans. 8.546 MW]
[Ans. 39.9, Pelton turbine] 18. From the investigation of a hydrosite the following data
is available :
10. The quantity of water available for hydro-electric station
is 260 m3/sec. under a head of 1.7 m. Assuming the speed Available head = 50 m ; catchment area = 50 sq. km. ;
of the turbine 50 r.p.m. and its efficiency of 82.5%, rainfall = 150 cm per year ; 70% of rainfall can be utilized;
determine the number of turbine units required. Assume turbine efficiency = 80% ; generator efficiency = 91% ;
the specific speed of 890. [Ans. 4] penstock efficiency = 75% ; load factor = 60%.
11. A run-off rate of 400 m3/sec and head of 45 m is available Determine the suitable capacity of a turbo-generator.
at a site proposed for hydro-electric power plant. Assuming [Ans. 750 kW (maximum rating), Francis
the turbine efficiency of 90% and speed of 250 r.p.m., find or Kaplan turbine]
the least number of machines all of equal size required if 19. Calculate the power that can be developed from a hydro-
(i) Francis turbine not greater than 200 specific speed or electric power station having the following data :
(ii) Kaplan turbine not greater than 600 specific speed is Catchment area = 100 sq. km. ; average value of annual
used. [Ans. (i) 16, (ii) 3] rainfall = 120 cm ; Run-off = 80% ; available head = 300 m;
12. At a proposed site of hydro-electric power plant the overall efficiency of the power station = 75%.
available discharge and head is 340 m3/sec. and 30 m [Ans. 7.48 MW]
respectively. The turbine efficiency is 88%. The generator 20. In a hydro-electric power plant the reservoir is 200 m above
is directly coupled to the turbine. The frequency of the turbine house. The annual replenishment of reservoir
generation is 50 Hz and number of poles used are 24. Find is 40 × 1010 kg. Calculate the energy available at the
least number of machines required if (i) A Francis turbine generating station bus bars if the loss of head in the
with a specific speed of 300 is used, (ii) A Kaplan turbine hydraulic system is 20 m and the overall efficiency of the
with a specific speed of 800 is used. [Ans. (i) 17, (ii) 2] station is 80%.
13. The following data relates to a hydro-electric power In the maximum demand of 40 MW is to the supplied
station : determine the diameter of two steel penstocks.
Head = 380 m ; Discharge = 4 m3/sec ; Turbine efficiency [Ans. 13.48 × 107 kWh ; 0.49 m]
= 80% ; Generator frequency = 50 Hz.
21. It is observed that a run-of-river power plant operates as
Determine : (i) Output, (ii) Type of turbine, (iii) Speed of peak load point with a weekly load factor of 24% all this
turbine. capacity being firm capacity. Determine the minimum flow
[Ans. (i) 16200 H.P., (ii) Pelton, (iii) 333 r.p.m., (corrected)] in river so that power plant may act as base load point.
392 POWER PLANT ENGINEERING
The following data is supplied : Rated installed capacity and generation are 84% and 89% respectively, determine
of generating plant = 12 MW ; Operating head = 18 m ; the plant efficiency. The power plant discharges directly
Plant efficiency = 85%. in the lower reservoir. [Ans. 71.2%]
If the stream flow is 17 m3/sec, calculate the daily load 24. At a particular site the mean discharge (in millions of m3)
factor of the plant. [Ans. 19.36 m3/sec. ; 21.2%] of a river in 12 months from January to December is
22. Find the firm capacity of a run-of-river hydropower plant respectively 80, 50, 40, 20, 0, 100, 150, 200, 220, 120, 100,
to be used as 9 hours peaking plant assuming daily flow 80.
in a river to be constant at 16 m3/sec. Also calculate (i) Draw a hydrograph and find the mean flow
pondage factor and pondage if the head of the plant is (ii) Also draw the flow duration curve
12 m and overall efficiency is 80%.
(iii) Find the power in MW available at mean flow if the
[Ans. 2048 H.P. ; 2.67 ; 5468 H.P. ; 8.64 × 105 m3]
head available is 100 m and overall efficiency of
23. The gross head of a pump storage power plant is 300 m. generation is 80%.
The diameter and length of the headrace tunnel are 3.8 m
Take the each month of 30 days.
and 650 m respectively. The flow velocity is 7 m/sec. and
friction factor is 0.017. If the overall efficiency of pumping [Ans. (i) 96.67 millions of m3/month, (iii) 29.2 MW]
8. Write in brief on the following : 14. (a) Sketch a layout of a hydraulic power plant suitable
(a) Type of hydro-electric plants and their field of use for high heads. Label the various parts and explain
(b) Solar power and its uses their functions.
(b) At a potential hydraulic plant site the average
(c) Function of surge tanks in hydro-electric plants.
elevations of head water and tail water levels are
9. (a) Explain the combined working of hydro and steam 605 m and 520 m respectively. The average annual
plants. water flow was determined to be equal to that volume
(b) Write a note on geo-thermal energy for power flowing through a rectangular channel 10 m wide and
generation. a depth of 0.12 m and an average velocity of 5 m/s.
10. (a) Discuss the differences between Kaplan, Francis and Find the annual electric energy in kWh that the site
Pelton turbines and state the types of power plants can produce with turbine efficiency of 85% and
they are suitable for. generator efficiency of 95%. Take the loss of head
(b) At a particular hydro-electric power plant site the works equal to 3% of the available head.
discharge of water is 400 m3/sec and the head is 25 m. 15. (a) What is a flow duration curve ? Explain its utility.
The turbine efficiency is 88%. The generator is directly (b) Define the specific speed of a hydraulic turbine. A
coupled to the turbine having frequency of generation hydro-electric power plant site is capable of developing
50 cycles/sec and number of poles as 24. Calculate the 101250 h.p. If the turbine has to work under a head of
least number of turbines required if (i) a Francis 29.5 m and at a speed of 166.7 r.p.m., find out the
turbine is used with a specific speed of 300, and (ii) a number of turbine units required.
Kaplan turbine with a specific speed of 750 is used. (c) Explain the governing method adopted for a large
11. (a) Draw a layout of a medium head hydro-electric plant Pelton wheel giving functions of each component of
using Francis turbines. the governor.
(b) A hydroplant operates under a mean head of 40 m. 16. (a) How is the cost of electrical energy generated
The reservoir has a catchment area of 480 square km. determined ? Explain the effect of load factor of an
Find the capacity of the plant in kW if the average electric power station on the cost per kWh generated.
annual rainfall in the area is 1100 mm and 20% of the (b) Discuss the advantages of operating storage type
rainfall is lost due to evaporation etc. The loss of head hydro-electric plant in combination with steam plant.
in the penstock is estimated to be 10%. The turbine 17. (a) Sketch hydrograph, flow duration curve and mass
efficiency is 85% and the generator efficiency is 92%. duration curves. Discuss the utility of each.
12. (a) Define hydrograph. How is the run-off measured in (b) Draw a pumped storage scheme and discuss how this
practice ? scheme results in overall economy in the case of inter-
(b) From the following table of the mean monthly connected station.
discharge for 12 months of a river at a site, draw (i) the (c) A hydro-electric scheme has a catchment area of
hydrograph and find the average monthly flow ; (ii) 120 sq. km. The available run-off is 50% with annual
the power available at mean flow of water for head 90 m rainfall of 100 cm. A head of 250 m is available on the
and overall efficiency of generation 90%. Take 30 days average. Efficiency of the power plant is 70%. Find (i)
in a month. average power produced, and (ii) capacity of the power
plant.
Month Q-m3 × 106
18. (a) Show schematically the layout of a hydro-plant. What
April 500 are the safety devices used in these plants ? Discuss
May 200 briefly the function of each.
June 1500 (b) The available quantity of water and head at a
July 2500 proposed site of hydro-electric power plant is
Aug. 3000 400 m3/sec and 30 m respectively. Assuming the
turbine efficiency of 90% and speed of 250 r.p.m., find
Sept. 2400
the least number of turbines required if (i) Francis
Oct. 2000 turbine with a specific speed of 300 is used, and (ii)
Nov. 1500 Kaplan turbine with a specific speed of 800 is used.
Dec. 1500 19. (a) Explain the construction of flow duration curve and
Jan. 1000 discuss its significance.
Feb. 800 (b) What do you understand by ‘pump storage power
Mar. 600 plant’ ? What are the advantages and limitation of this
plant ? Where should such plants be best applied ?
13. (a) Why is governing of hydraulic turbines necessary ? (c) Define specific speed as applied to water turbines.
Explain the governing mechanism of a Kaplan turbine. What information does specific speed give and how is
(b) Derive an expression for the specific speed of a it used in practice ?
hydraulic turbine and calculate it for a turbine 20. (a) What different methods are used to measure the
operating under a head of 24 m and running at 400 rainfall ? Explain any one of them.
r.p.m. The rate of discharge is 9 m3/sec and turbine (b) Define hydrograph and explain its importance in the
is 90%. design of storage type hydro electric power plants.
394 POWER PLANT ENGINEERING
(c) A run-off rate of 400 m/s and head of 45 m is available (b) Compare steam and hydro plants as regards fixed and
at a site proposed for hydro-electric power plant. operating costs.
Assuming the turbine efficiency of 90% and speed of (c) The yearly duration curve of a certain plant can be
250 r.p.m. find the least number of machines all of considered as a straight line from 20000 to 3000 kW.
equal size required if (i) Francis turbine not greater To meet this load three turbo-generator units, two
than 200 specific speed or (ii) Kaplan turbine not rated at 10000 kW each and one at 5000 kW, are
greater than 600 specific speed is used. installed. Determine installed capacity, capacity factor
21. (a) What different methods are used to find the average load factor and utilization factor.
rainfall ? Discuss the relative merits. Explain the 27. (a) What are the advantages and disadvantages of a
methods. hydroelectric power plant over a thermal one ?
(b) A test is conducted on a model of 41 size of prototype (b) What do you mean by ‘specific speed’ of a water turbine
? State its significance.
under the head of 36 m to find the performance of
prototype. The head available for the prototype is (c) Describe a method of governing a Pelton wheel with a
100 m and it has to run at 428 r.p.m. Find the power neat sketch.
developed by the prototype. The H.P. developed by the 28. (a) Name the different types of hydraulic turbines used
model is 135 H.P. when the water supplied is in hydel power stations. Also discuss briefly the
0.324 m3/s. Assume the efficiency of the prototype 3% suitability of each type for a particular range of net
greater than the efficiency of the model. State the type heads.
of runner used. (b) Classify hydro plants and explain the use of each plant.
22. Write short notes on the following (5 × 4) : (c) Describe briefly the working of a pumped storage
(i) Governing of water turbines ; plant. Where can each type of plant be installed ?
(ii) Circuit breakers ; 29. (a) Explain the importance of hydrograph and flow
(iii) Magneto hydrodynamics (MHD) ; duration curve on the selection of reservoir storage
(iv) Moderators in nuclear power plants. capacity. What do you understand by a ‘pump storage
23. (a) Explain the various methods used for calculating the plant’ ?
average of rainfall depending upon the area of basin. (b) The table below provides data on the load requirement
(b) What are the different factors to be considered while during 24-hour period at a certain location :
selecting the site for hydro-electric power plant ? Time period Load in mW
(c) A turbine is to run at 200 r.p.m. under the
available head of 25 m. The flow rate available is 12 mid-night to 6 am 20
9 m3/sec. If the turbine efficiency is 90%, calculate (i) 6 am to 10 am 100
the specific speed, (ii) power developed, and (iii) speed 10 am to 6 pm 160
and power, if the head is reduced to 15 m. 6 pm to 8 pm 80
24. (a) Describe the function of surge tank and penstock used 8 pm to 12 mid-night 40
in the storage type hydro-electric plant. If the load is shared by a combination of thermal and ‘pump
(b) Explain briefly with line sketch a typical high pressure storage hydroplant’ with the thermal plant carrying the
intake head works for a hydro-electric power station. base load lying somewhere between 80 MW, 100 MW,
(c) A model is to be designed to find the performance of a estimate the energy supplied to the thermal plant in MWh
prototype Francis runner. The prototype turbine has during 24 hours and the overall efficiency of the combined
to develop 50,000 hp under a head of 225 m. The plant.
available head and flow in the laboratory for model Assume thermal at full load = 35%
testing are 36 m and 0.17 m3/sec. The prototype runner pump = 80%
runs at 600 r.p.m. and assuming overall efficiency of hydraulic turbine = 90%.
90%, calculate (i) suitable scale ratio for the model,
30. (a) Enumerate the factors that you would consider while
(ii) power developed by the model, and (iii) the speed
installing a hydropower plant.
of the model runner.
(b) A turbine developing 7353 kW at a head of 27.4 with
25. (a) What are the factors to be taken into consideration an overall efficiency of 80%, is to be supplied from a
for the selection of a hydro-electric plant ? reservoir. The estimated run-off in m3/month for 12
(b) Draw line sketch of a small medium head hydroplant consecutive months of 30 days is given below :
showing dam, headworks, penstock and powerhouse. 107 × (9.64, 10.2, 8.64, 7.51, 6.8, 8.08, 11.34, 9.07, 8.64,
(c) A hydro-electric station is to be designed for a 11.35, 9.92, 8.93)
catchment area of 102.5 sq. km, run-off 70 per cent Assuming that the reservoir is full at the beginning
and the average rain as 127 cm. The head available is determine (i) the minimum capacity of the reservoir to
381 metres. What power in MW can be developed if assure the required demand, and (ii) the quantity that is
the overall efficiency of the plant is 80 per cent ? wasted during the year.
26. (a) What are the principal factors that make up the unit 31. Write notes on any two of the following :
cost of power generation in a power plant ? Explain in (i) Surge tanks ; (ii) Storage and pondage ;
brief how each affects the output cost. (iii) Electrostatic precipitators.
Nuclear Power Plant 7
7.1. General aspects of nuclear engineering—Atomic structure—Atomic mass unit—Isotopes— Radioactivity—Nuclear radiation—
Binding energy—Radioactive decay—Nuclear reactions—Nuclear cross-sections—Fertile materials—Fission of nuclear fuel—Nuclear
Fusion—Comparison of fission and fusion processes. 7.2. Nuclear power systems. 7.3. Nuclear reactors—Introduction—
Classification of nuclear reactors—Essential components of a nuclear reactor—Power of a nuclear reactor. 7.4. Main components
of a nuclear power plant. 7.5. Description of reactors—Pressurised water reactor (PWR)—Boiling water reactor (BWR)—CANDU
(Canadian-Deuterium-Uranium) reactor—Gas-cooled reactor—Liquid metal cooled reactors—Breeder reactor. 7.6. Selection of
materials for reactor components. 7.7. Metals for nuclear energy. 7.8. Advantages of nuclear power plants. 7.9. Nuclear-plant
site selection. 7.10. Application of nuclear power plants. 7.11. Economics of nuclear power plants. 7.12. Safety measures for
nuclear power plants. 7.13. Nuclear power plants in India. 7.14. Future of nuclear power. 7.15. Useful by-products of nuclear
power generation and their uses—Worked Examples—Highlights—Theoretical Questions—Unsolved Examples—Competitive
Examinations Questions.
7.1. GENERAL ASPECTS OF NUCLEAR — The electrons carry negative charge and circulate
about the nucleus. As the positive charge on
ENGINEERING proton particle is equal to the negative charge
on electron particle, and the number of electrons
7.1.1. Atomic Structure is equal to the number of protons, atom is a
— Atomic model. An element is defined as a neutral element. Any addition of the number of
substance which cannot be decomposed into electrons to the neutral atom will make it
other substances. The smallest particle of an negatively charged. Similarly any subtraction
element which takes part in chemical reaction of the electrons will make it positively charged.
is known as an ‘atom’. The word atom is derived Such an atom is known as ion and the process
from Greek word ‘Atom’ which means indivisible of charging the atom is termed an ionisation.
and for a long time the atom was considered as — The nuclear power engineering is specially
such. Dalton’s atomic theory states that (i) all connected with variation of nucleons in nucleus.
the atoms of one element are precisely alike, Protons and neutrons are the particles having
have the same mass but differs from the atoms the mass of about 1837 times and 1839 times
of other elements, (ii) the chemical combination the mass of an electron.
consists of the union of a small fixed number of
— The modern atomic theory tells that the atom
atoms of one element with a small fixed number
has a diameter of about 10–7 mm. In a neutral
of other elements.
atom the electrons are bound to the nucleus by
Various atomic models proposed by scientists the electrostatic forces, which follows the
over the last few decades are : 1. Thompson’s Coloumb’s law of forces, i.e., like charges repel
plum puddling model, 2. Rutherford’s nuclear and unlike charges attract each other. The
model, 3. Bohr’s model, 4. Sommerfeld’s model, function of electrostatic force is similar to the
5. Vector model, 6. Wave-mechanical model.
gravitational force.
— The complex structure of atom can be classified
— The atomic spectrum study has revealed that
into electrons and nucleus. The nucleus consists
every electron in an atom is in one group of
of protons and neutrons both being referred as
specific states of motion which is corresponding
nucleons. Protons are positively charged and
to its total energy. In an atom the electrons are
neutrons are neutral, thus making complete
spinning around the nucleus in orbits. These
nucleus as positively charged.
395
396 POWER PLANT ENGINEERING
orbits are called shells, which represent the required number of electrons from the adjacent
energy levels for the electrons. All the electrons atom in a matter. The binding force between
having very nearly the same total energy are said the electron and nucleus is the electrostatic force
to be in the same shell. The shells have been of attraction. To emit one electron energy
named as K, L, M, N etc. Each shell consists of required is more than the electrostatic force of
the specific maximum number of electrons. The attraction. When the energy is supplied, the
K shell (inner shell) contains 2 electrons, L shell electron jumps from one discrete energy level to
has 8 electrons, M shell is limited to 18 and the another permissible level. The process starts from
N shell possesses 32 electrons. In fact, the outer shell. The electron possesses the energy
number of electrons in any orbit is equal to 2n2 in two forms, i.e., kinetic energy due to its
where n is the serial number of the orbit taking motion and potential energy due to its position
first orbit nearest to the nucleus, with the with respect to the nucleus. It is obvious that
exception that the outermost orbit cannot have electrons cannot exist in between the permissible
more than eight electrons . In a given atom all orbits.
orbits may not be complete. It is obvious from — The charge of nucleus is represented by the
the study that amplitude difference in energy number of protons present. This number is
between two shells is much more than the known as atomic number and designated by the
difference in between energy levels in one shell. letter Z. It also shows the position of atom in
In a shell less than the specified number of the periodic table. Hydrogen has only one
electrons may exist but not a large number. The number but natural uranium has ninety two.
inner shell is filled up first and then the other The atoms having higher atomic number have
successive shells are completed. been developed artificially ranging from 93 to
— The chemical properties of the atom varies with 102. These are einsteinium (Z = 99), Ferinium
composition of number of electrons in various (Z = 100), and mendelevium (Z = 101).
shells and the state of energies within the shells Platonium (Z = 94) is an important element to
determine the electrical characteristics of the the nuclear power field.
atom. For example, Hydrogen (H2) consists of The mass number (A) is the sum of total number of
one electron in the first shell, Helium (He) has protons and neutrons in a nucleus. The number of electrons
two electrons in the first shell, Lithium (Li) has is represented by the letter N, i.e., N = (A – Z).
two electrons in first shell and one is second
shell, Carbon (C) consists of two electrons in first 7.1.2. Atomic Mass Unit
and four in second shell. The mass of the atom is expressed in terms of the mass of
1
Nucleus the electron. The unit of mass has been considered as th
16
Electron of the mass of neutral oxygen atom which contains 8 protons
Shell and 8 neutrons. The atomic mass unit (a.m.u.) is equal to
1
th the mass of oxygen neutral atom.
+1 K +2 K
16
One a.m.u. = 1.66 × 10–24 g
Electron volt. The energy is expressed in electron method. Thus, for any isotope, the quantity of radiation
volt unit. An electron volt = work done in moving an electron per unit time can be determined easily.
by a potential difference of one volt. Or it is the amount of
energy acquired by any particle with one electronic charge, 7.1.4. Radioactivity
when it falls through a potential of one volt. Radioactivity was originally discovered by Becquerel in
One electron volt = 1.602 × 10–19 joule. 1896. This phenomenon is confined almost entirely to the
heaviest element from 83 to 106 in the periodic table.
7.1.3. Isotopes The phenomenon of spontaneous emission of powerful
In any atom, the number of electrons = number of protons. radiations exhibited by heavy elements is called
This is independent of neutrons in the nucleus. Atoms ‘radioactivity’. Radioactivity is essentially a nuclear
having different number of neutrons than the number of phenomenon and is a drastic process because the element
protons are known as ‘Isotopes.’ changes its kind. It is spontaneous and an irreversible self-
Example. Isotopes of hydrogen are shown in Fig. 7.1 (b). disintegrating activity because the element breaks itself up
for good. Those elements which exhibit this activity are called
radioactive elements. Examples are : Uranium, polonium,
radium, radon, ionium, thorium, actinium and mesothorium.
+ + n + n
The radioactive radiations emitted by the
n radioactive elements are found to consist of the following :
(i) Alpha () rays or -particles
H1 – Hydrogen H2 – Heavy hydrogen H3 – Heavy hydrogen
(ii) rays or -particles
(No Neutron) or Deuterium – D or Tritium – T
(iii) -rays or photons.
Fig. 7.1 (b) The radioactivity may be natural or artificial.
These isotopes have the same chemical properties Natural radioactivity. It is that which is exhibited
and have the same atomic number and occupy the same by elements as found in Nature. It is always found in heavier
place in the periodic table. But the nuclear properties of elements in the periodic table.
each of the isotopes are different because of the different Artificial or induced radioactivity. The modern
number of neutrons in the nucleus. techniques of artifical transmutation of elements have
The isotopes of oxygen vary from O14 to O19. The made it possible to produce radioactivity in many other
change of number of neutrons in nucleus affect the mass of elements much lighter than those that occur in Nature.
atom. Such type of radioactivity is known as artificial or induced
radioactivity.
Example. Weight of heavy hydrogen is twice the weight
of simple hydrogen. This means a volume of H2O weighs The general properties of radioactive radiations are :
less than the same volume of D2O. 1. These radiations are highly penetrating, they affect
The isotopes can be represented with mass number photographic plates, ionise gases, cause scintillations on
(A) as subscript and atomic number (Z) as subscript like fluorescent screen, develop heat and produce chemical changes.
A 2. As radiations are given out, new elements are
ZH .
Example. Hydrogen isotopes are represented as 1H2 formed in an irreversible process—the new elements
(Deuterium), 1H3 (Tritium) and Uranium isotopes as U234, themselves being usually radioactive.
U235, U238. 3. The emission of radiations is spontaneous and is
— The isotopes are not stable and disintegrate at not affected by external agents.
a certain rate. The isotope which disintegrates 4. The emission is not instantaneous but is prolonged
at a fixed rate is called Radioactive isotope or i.e., it is extented over a period of time otherwise it would
Radio isotope. not have been discovered at all.
The instability of the nucleus can be either by the 5. Except for radioactivity, there is nothing
separation of parent nucleus into 2 or more nuclei or by abnormal about the radioactivity elements as regards their
the rearrangement of nucleons in the matter so that there physical and chemical properties.
is an emission of particles or energy in the form of rays or 7.1.5. Nuclear Radiation
by rearrangement of electrons. During this transformation
there is emission of particles at a very high velocity. This In nuclear power technology there are only five types of
is known as radiation. radiation of interest, but there many mechanisms by which
We must note that for any specific isotope, the rate these five are produced in reactor systems. The five types
of radiation from a unit mass and also the energy of radiation (with electrical charges indicated as + or – for
distribution are fixed and cannot be changed by any positive or negative, respectively, and mass in atomic mass
398 POWER PLANT ENGINEERING
radiation. Ionization is the production of electrically of atom. In nuclear physics, the first even or odd represents
charged particles by stripping orbital electrons from the the even or odd number of protons respectively and second
electrically neutral atoms. In the case of neutrons, the one represents the even or odd mass number. This is
primary energy-transfer process is a kinetic-energy obvious from the practical data that the U235 is fissionable
exchange caused by collision of neutrons with nuclei of the with slow neutrons (neutrons having less energy) but U238
matter traversed. is fissionable only when the neutrons are having energy
more than 1 MeV.
7.1.6. Binding Energy
The nucleus of an atom is formed when the nucleons come 9
closer to each other and this distance between the two Ni58
nucleons is of the order of nearly 10–12 mm. At the moment 8
zN0
N dN
N
z t
0
dt ...(7.3)
Now integrating by parts, we get
L
T = M t e
t
e t OP
1
...(7.9)
or loge N – loge N0 = – t or loge
N
N0
= –t MN PQ 0
0.693
N But t1/2 =
or = e–t or N = N0 e–t ...(7.4)
N0
From the above eqns. it is clear that mean life is
dN 1.445 times greater than half-life.
= – N = – N0 e–t ...(7.5)
dt
Note. Number of disintegrations per second is the unit
The eqn. (7.5) represents that the decay scheme
of radioactivity and is termed curie, as this phenomenon
follows the exponential law. was first discovered by Curie.
Activity :
The intensity of emitted radiation is termed activity. 7.1.8. Nuclear Reactions
This is directly dependent on the rate of During a nuclear reaction, the change in the mass of the
disintegration of the element. particle represents the release or an absorption of energy. If
If, A = activity at time t, the total mass of the particle after the reaction is reduced,
A1 = initial activity, the process releases the energy, consequently, the increase
k = detection coefficient, in the mass of the resultant particle, will cause the
dNFG IJ absorption of energy.
Then, A=k
dtH = kN
K The equations of nuclear reactions are connected with
the resettlement of protons and neutrons within the atom.
= kN0 e–t = A1 e–t ...(7.6) The equations are much similar to chemical reactions. The
Half-life : energy variation is also of the order of MeV. In simple term
Half-life represents the rate of decay of the radioactive the equation shows the balance of neutron and proton.
isotopes. The half-life is the time required for half of the A nuclear reaction is written as follows :
parent nuclei to decay or to disintegrate.
(i) The bombarded nuclei or the target nuclei is
N0 written first from left hand side.
Putting N = and t = t1/2 in eqn. (7.6), we get
2 (ii) In the middle within brackets, first is the
N0 incident particle and second one the ejected.
= N0 e t1/ 2 e t1/ 2 = 1/2
2 (iii) On the right hand side, the resultant nucleus is
0.693 placed.
t1/2 = loge 2 = 0.693 t1/2 = ...(7.7)
A neutron is written as : 0n1 because it has unit mass
Here t1/2 is the half-life of radioactive nuclei. After and it does not have any charge.
passing every half-life the number of nuclei is reduced to half An electron is written as : –1e0 because its mass is
and so is the activity. This process is repeated for the several negligible as compared to proton or neutron and its charge
half lives till the activity becomes negligible. The variation of is equal but opposite to the charge of proton.
half-life is from fraction of seconds to million of years.
Some of the examples of reactions are given below :
Half-life of some of the metals is given below :
(i) When 11Na23 is bombarded with protons
Metal Half-life
possessing high energy, it is converted to 12Mg23
Po-214 170 sec 23 + H1 Mg23 + n1 + q
I-137 25 sec 11Na 1 12 0 ...(7.10)
Carbon-14 5100 years (where q = release or absorption of energy in the reaction)
Th-232 1.4 × 1010 years (ii) When 13Al27 is bombarded with high energy
Uranium-238 4.525 × 109 years protons it is transformed to 14Si27.
27 + H1 Si27 + n1 + q
Average (mean) life : 13Al 1 14 0 ...(7.11)
This indicates the average of total time for which (iii) When 13Al27 is bombarded with deutrons, Al28
the radioactive nuclei has disintegrated for several half and proton may be produced.
lives. Hence this is greater than half-life. This is obtained 27 + H2 28 + H1
13Al 1 13Al 1 ...(7.12)
by taking the sum of the decay time of the radioactive nuclei
The eqns. (7.10), (7.11) and (7.12) may be written in
and then it is divided by the initial number of nuclei.
the equation form as given below :
If T is the time of average life, then
z z
Na23(p, n)Mg23 ...(7.13)
27 27
t dN N0 t e t dt 13Al (p, n)Si ...(7.14)
0 0
T= ...(7.8) Al27(d, p)Al28 ...(7.15)
N0 N0
NUCLEAR POWER PLANT 401
It is evident from the above mentioned reactions possibilities of producing the stable and unstable nucleus
that the nuclear reaction is followed by capturing a particle, and may result in (n, ) or (p, ) reactions. This
resulting in a compound excited nucleus, which undergoes transformation may take place with elastic scattering.
further transformation in a short period of time. When a neutron interacts with light hydrogen, it forms
The transformation may adopt the following five heavy hydrogen, deuterium. The mass of deuterium is less
main different paths : than its components. This mass defect is corresponding to
1. Elastic scattering. The neutron interacts with the release of gamma quantum.
the nucleus and after transformation the compound nucleus 4. In this reaction, the impinging particle is trapped
emits a particle which is identical to the captured one. in the nucleus but the ejected particle is a different one. The
There is also no change in the resultant nucleus. The total composition of the resultant nucleus is also different from
internal energy of the bombarded nucleus and the restriking the parent nucleus.
particle will not change at all. The process is known as 5. Fission. When the nucleus is excited too much, it
elastic scattering. Elastic scattering is also termed as elastic splits into two mostly equal masses. This particular reaction
collision. When the neutron strikes the nucleus, it imparts is suited only to the heavy nucleus such as U233, U235, Pu239
the part of initial kinetic energy and momentum to the etc. The transformation is known as fission. The produced
nucleus which causes the displacement of the nucleus in two nuclei are lighter nuclei ; they have more binding
the crystal lattice by a significant distance and can change energies per nucleon and hence this reaction always releases
the structural properties of the material. the energy (Fig. 7.2).
In elastic scattering process the kinetic energy of
7.1.9. Nuclear Cross-Sections
neutron is reduced and is beneficial to slow down the
neutron is reactor. In this transformation, there is neither Cross-sections (or attenuation coefficients) are measures of
release nor absorption of energy but as a result of collision, the probability that a given reaction will take place between
redistribution of kinetic energy takes place. a nucleus or nuclei and incident radiation.
Example of elastic scattering. When a neutron Cross-sections are called either microscopic or
strikes a light nucleus (e.g. hydrogen nucleus), the velocity macroscopic, depending on whether the reference is to a
of the neutron is very much reduced and the energy is single nucleus or to the nuclei contained in a unit volume
transferred to the proton. Here most of the energy is of material.
transferred because both the particles are having nearly Microscopic cross-section
the same masses. It has been observed that in such a single
It is a measure of the probability that a given reaction
collision, the loss of energy of the proton is nearly 70 to 75
will take place between a single nucleus and an incident
per cent. In case the neutron impacts with the heavy
particle. Microscopic cross-section is usually denoted by the
nucleus, the energy loss in single collision is less. With
symbol and is expressed in terms of the effective area that
carbon nucleus this loss amounts to nearly 12 to 17 per cent
a single nucleus presents for the specified reaction. Since these
of the initial value. The reaction is written as C12(n, n)C12.
cross-sections are usually quite small, in the range of 10–22
2. Inelastic scattering. The composition of the to 10–26 cm2/nucleus it is general practice to express them in
incident particle and ejected particle remains unchanged. terms of a unit called the barn, which is 10–24 cm2/nucleus.
When the particle interacts with the nuclei it loses its
kinetic energy and the target nucleus is excited. The energy Macroscopic cross-sections
is released in the form of gamma emission. This These are the products of microscopic cross-sections
transformation is known as inelastic scattering or collision. and the atomic density in nuclei per cubic centimeter and
The process is limited to the condition that the neutron are equivalent to the total cross-section, for a specific
should have minimum energy sufficient to excite the target reaction of, all the nuclei in 1 cm3 of material. Macroscopic
nucleus. The reaction is completed with the absorption or cross-sections are denoted by the symbol for neutrons
release of energy. The neutron energy loss is of the order and for gamma rays and have the units cm–1.
of 10 to 20 per cent of the initial value.
Gamma ray cross-sections
When a fast moving neutron hits the U238 nucleus,
the nucleus is excited and there is an emission of gamma Although there are a large number of interaction
quantum [U238 (n, ) U238]. processes that take place between gamma rays and matter,
the most commonly used are the energy-absorption cross-
3. Capture. In this process the incident particle may
section (used to determine gamma heating and dose rates)
be captured or absorbed by the nucleus and may raise the
and the total attenuation cross-section (used to determine
mass number by unity. The nucleus is excited and the
material gamma-ray attenuation and for shielding design).
energy is emitted in the form of gamma quantum. The
artificial radioactive materials are produced by this process. Neutron cross-sections
In a reactor, Co-60 isotope is produced by bombarding the Neutrons undergo a large number of different
natural Co-59 with neutrons. The reaction has both the interaction processes with matter, and, unlike gamma rays,
402 POWER PLANT ENGINEERING
many of these individual interactions must be evaluated. The nuclear transformations to convert 232
90Th to
Neutron cross-sections of general use are : U233 are given below :
(i) Fission (ii) Gamma-ray production 232 + n1 233 +
90Th 0 90Th ...(7.19)
(iii) Activation (iv) Elastic scattering 23.3 min.
233 233 0
(v) Inelastic scattering 90Th 91Pa + –1e ...(7.20)
(vi) Reaction particle production 27.4 days
233 233 + –1e0
(vii) Total absorption (viii) Total attenuation. 91Pu 92U ...(7.21)
Both neutron and gamma-ray cross-sections are U235 is the source of neutrons required to derive
energy-dependent properties. Plots of gamma-ray cross- Pu239 and U233 from Th232 and U238 respectively. This
section vs photon energy for all materials are, over the process of conversion is performed in the breeder reactors.
energy range of interest, smooth curves, whereas for Other fissionable materials : Th227, Pa232, U231,
Np 238 and Pu241 are the other nuclides which are having
neutron cross-sections the curves of many materials show
gross variations from a smooth curve. The variations in high cross-sections for neutron thermal fission. Pu241 is the
neutron cross-sections show up as peaks and valleys on important nuclide which is used in plutonium fueled power
the cross- section plot ; these peaks are called resonances. reactors.
When a material has a large number of resonance peaks
over a portion of the energy range, this portion of the cross- 7.1.11. Fission of Nuclear Fuel
section plot is called a resonance region. The resonance Fission is the process that occurs when a neutron collides
region can have a significant effect on reactor design, since with the nucleus of certain of the heavy atoms, causing the
the material U238 which is present in most fuels has a original nucleus to split into two or more unequal fragments
relatively wide resonance region which can cause extensive which carry off most of the energy of fission as kinetic energy.
neutron absorption during the slowing down of neutrons This process is accompanied by the emission of neutron and
to thermal energy. gamma rays.
The known cross-sections for materials potentially Fig. 7.3 is a representation of the fission of uranium
useful in reactor systems are used as primary criteria in 235. The energy released as a result of fission is the basis
materials selection. For example, high-neutron-absorption for nuclear-power generation. The release of about 2.5
cross-section materials would not normally be used as neutrons/fission makes it possible to produce sustained
materials of construction in the vicinity of a reactor core to fissioning.
prevent competition for the neutrons required to sustain
the fission process ; and high activation cross-section Prompt gamma rays
materials would not be chosen, if they can be avoided, in a
region exposed to a high neutron flux during operation, if Fission fragment
that region is to be accessible after reactor shut-down.
U-235 Prompt neutron
7.1.10. Fertile Materials
Incident
It has been found that some materials are not fissionable neutron Fission fragment
by themselves but they can be converted to the fissionable
materials, these are known as fertile materials.
Prompt neutron
Pu239 and U233 are not found in nature but U238 and
Th can produce them by nuclear reactions. When U238 is
232
Fig. 7.3. Fission of uranium 235. Incident neutron, upon
bombarded with slow neutrons it produces 92U239 with half- colliding with U235 nucleus, causes fission to take place, resulting
life of 23.5 days which is unstable and undergoes two beta in the production of fission fragments, prompt neutrons and
disintegrations. The resultant Pu239 has half-life of 2.44 × prompt gamma rays.
104 yrs and is a good alpha emitter. The fission fragments that result from the fission
238 + n1 239 +
92U 0 92U ...(7.16) process are radioactive and decay by emission of beta
23.5 min. particles, gamma rays and to a lesser extent alpha particles
239 0 231
92U – –1e + 91Np ...(7.17)
and neutrons. The neutrons that are emitted after fission,
2.3 days by decay of some of the fission fragments, are called delayed
239
93Np –1e0 + 94Pu239 ...(7.18)
neutrons. These are of the utmost importance, since they
During conversion the above noted reactions will
permit the fission chain reaction to be easily controlled.
take place. The other isotopes of neptunium such as 2.1
day Np238 and plutonium can also be produced by the The total detectable energy released owing to the
bombardment of heavy particles accelerated by the fission of a single nucleus of uranium 235 is 193 MeV (milli
cyclotron. electron volts), distributed as shown follows :
NUCLEAR POWER PLANT 403
Delayed total 13
235
As is shown above, the neutron emitted as a result U
of fission of a uranium 235 nucleus carry off 5 MeV of kinetic
energy. Since on average there are about 2.5 neutrons
emitted/U235 fission, the average neutron energy is 2 MeV.
Actually fission neutrons are emitted with an energy speed
of from nearly zero energy to approximately 16 MeV, the
bulk of the them being in the 1- to 2-MeV energy region.
Note. Although not strictly a result of the fission process,
there is an additional 5 to 8 MeV emitted per fission as a
result of the capture of neutrons not used in the fission
chain reaction. About 1 MeV of this total is emitted over a
period of time owing to decay of activation products, and
the remainder is emitted immediately upon neutron
capture.
Requirements of fission process natural uranium requires a large critical mass (and size)
The requirements of fission process may be summed and the use of moderator and materials of construction
up as follows : which have very low absorption cross-sections. To reduce
1. The neutrons emitted in fission must have the critical mass required and permit more flexibility in
adequate energy to cause fission of another nuclei. material and design choice, uranium fuel is frequently
enriched in U235 content, thereby increasing the fraction of
2. The produced number of neutrons must be able
neutron captures that occur in U235 and cause fission.
not only to sustain the fission process but also to increase
the rate of fission. Certain loss of neutrons during the 7.1.12. Nuclear Fusion
process is also to be accounted.
‘Nuclear Fusion’ is the process of combining or fusing two
3. The process must be followed by the liberation of lighter nuclei into a stable and heavier nuclide. In this case
energy. also, large amount of energy is released because mass of
4. It must be possible to control the rate of energy the product nucleus is less than the masses of the two nuclei
liberation i.e., the rate of fission by some means. which are fused.
Since the chain reaction requires that one neutron Several reactions between nuclei of low mass
from each fission cause another fission, it is worth noting numbers have been brought about by accelerating one or
that there are several processes competing for the neutrons the other nucleus in a suitable manner. These are often
produced. These processes are non-fission capture in the fusion processes accompanied by release of energy.
fuel material, capture in the fuel container (cladding), core However, reactions involving artificially-accelerated
structural materials, moderator and coolant, and leakage particles cannot be regarded as of much significance for
of neutrons from the core. To permit a chain reaction to the utilisation of nuclear energy. To have practical value,
take place, it is necessary to design a system in which, after fusion reactions must occur in such a manner as to make
accounting for all neutron losses due to non-fission them self-sustaining, i.e., more energy must be released than
absorption and leakage, there is still at least one neutron is consumed in initiating the reaction.
remaining to produce another fission. It is thought the energy liberated in the sun and
The minimum quantity of fuel required for any other stars of the main sequence type is due to the nuclear
specific reactor system is called the ‘critical mass’ and the fusion reactions occurring at the very high stellar
size associated with this mass is called the ‘critical size’. temperature of 30 million K. Such processes are called
When nuclear fuel is assembled just to the point of a critical thermonuclear reactions because they are temperature-
mass, the reactor is said to “go critical” i.e., to reach the dependent.
point of just sustaining a chain reaction. Natural uranium
contains only about 0.7% of the fissile isotope U235. Since 7.1.13. Comparison of Fission and Fusion Processes
U238 which makes up the balance absorbs neutrons, a The comparison between ‘Fission’ and ‘Fusion’ processes
nuclear reactor which will sustain a chain reaction with is given below :
Fission Fusion
1. When heavy unstable nucleon is bombarded with 1. Some light elements fuse together with the release of
neutrons, the nucleus splits into fragments of equal mass energy.
and energy is released.
2. About one thousandth of the mass is converted into energy. 2. It is possible to have four thousandths of mass converted
into energy.
5. Because of higher radioactive material, health hazards is 5. Because of lesser radioactive material, health hazards is
high in case of accidents. much less.
6. It is possible to construct self-sustained fission reactors 6. It is extremely difficult to construct controlled fusion
and have positive energy release. reactors.
7. Manageable temperatures are obtained. 7. Needs unmanageable temperatures like 30 million degrees
for fusion process to occur.
8. Raw fissionable material is not available in plenty. 8. Reserves of deuterium, the fusion element, is available in
great quantity.
NUCLEAR POWER PLANT 405
7.2. NUCLEAR POWER SYSTEMS the power- conversion cycle or indirectly to heat another
fluid to be used as the working fluid.
A nuclear-fueled power-producing system consists In some cases an intermediate heat-transfer loop is
essentially of the following : inserted between the reactor coolant and the working fluid,
(i) A controlled fission heat source. to increase isolation of the radioactive reactor coolant from
(ii) A coolant system to remove and transfer the heat the conventional power-producing equipment. The working
produced. fluid is then used to drive a turbo-generator set to produce
electrical power.
(iii) Equipment to convert the thermal energy
Though several other methods are feasible for direct
contained in the hot coolant to electric power. conversion of fission energy to electric power (i.e.,
Regardless of the type of fission heat source used, thermoelectric, thermionic, photoelectric, etc.), these
the basic mechanism is fission of nuclear fuel to produce methods are not at present suitable for the production of
thermal energy. This thermal energy is removed from the large quantities of power.
heat source (reactor core) by contacting the fuel with a Schematic representations of nuclear power systems
coolant which can be used directly as the working fluid in using the direct, indirect, and indirect with intermediate
heat-transfer approaches are shown in Fig. 7.6.
Working fluid
Reactor
Turbine Generator
Condenser
Cold reactor coolant
Pump
(a)
Heat
Reactor
Cold Condenser
Cold reactor working
Pump
coolant fluid
(b) Pump
Heat Heat
Reactor
Fig. 7.6. Schematics of nuclear power systems. (a) Direct cycle, reactor coolant used as the working fluid ; (b) Indirect cycle,
reactor coolant transfers heat to separate working fluid ; (c) Indirect cycle with intermediate loop, reactor coolant transfers heat
through intermediate heat-transfer loop to working fluid.
406 POWER PLANT ENGINEERING
Nuclear power systems differ in a number of respects 1. Neutron energies at which the fission occurs
from fossil-fuel systems. Some of the more important (i) Fast fission is caused Fast reactors
considerations that differentiate nuclear-fueled plants from by high energy neutrons
fossil-fueled plants are listed below : (ii) Intermediate or epithermal Intermediate
1. Nuclear fuel is charged to a power plant reactors
infrequently and has a relatively long life, usually
(iii) Low energy i.e., thermal Slow reactors
measured in months or years, as compared with the
continuous fuel-feed requirements for fossil-fueled plants. On the basis of the energy of the neutrons to cause
fission the reactors have been divided into three groups—
2. Burned nuclear fuel is radioactive ; it requires
remote handling and special processing and disposal. fast, intermediate and thermal. (a) In fast reactors the
high velocity neutrons produced by fission are utilised
3. Major portions of a nuclear plant are radioactive
directly to cause fission of the fuel in the reactor. The
during and after operation, requiring special precautions
velocity of the neutrons is not reduced deliberately. (b) If in
for maintenance of much of the plant.
a reactor the fission process is maintained due to the slow
4. Special system designs are required to prevent
neutrons capture, the reactor is known as slow reactor.
radioactivity release during normal operation or due to
The minimum velocity to which neutrons are slowed down
accidents.
before the fission is equal to the thermal velocity which
5. Control and instrumentation requirements are the slow neutrons may acquire in a state of thermal
strongly influenced by safety requirements and are related
equilibrium with the medium. This velocity is of the order
to reactor stability, load-following requirements, and the
of 2150 m/s at room temperature which is equivalent to
capability of a reactor to increase power output with no
additional fuel input. 1
eV or neutron energy. The neutrons associated with
6. Nuclear fuel is highly processed material 40
generally used in a precise fabricated form, as opposed the energy of this order are known as thermal neutrons
to fossil fuels, which are essentially raw materials used and the reactor as thermal reactors. With the moderator
with only minimal rough processing. the neutrons are slowed down. The main advantage is that
7. The use of nuclear fuel does not require the probability of reaction increases. (c) If the velocity of
combustion air, thus obviating thermal stack losses and neutrons is kept between both the above noted limits, the
related problems. reactors are termed as ‘intermediate reactors’.
These considerations give rise to the general 2. Fuel-moderator assembly
requirements, complexities, and problems of nuclear systems. (i) Homogeneous reactors
(ii) Heterogeneous reactors.
7.3. NUCLEAR REAC TORS
In ‘homogeneous reactor’ the fuel and moderator are
7.3.1. Introduction mixed to form a homogeneous material, i.e., uranium fuel
salt forms a homogeneous solution in water which is a
Definition. A nuclear reactor is an apparatus in which moderator or fine particles of uranium and carbon gives a
nuclear fission is produced in the form of a controlled self- mechanical mixture.
sustaining chain reaction. In other words, it is a controlled
In ‘heterogeneous reactor’ the fuel is used in the form
chain-reacting system supplying nuclear energy. It may
be looked upon as a sort of nuclear furnace which burns of rods, plates, lamps or wires and the moderator surrounds
fuels like U235, U233 or Pu239 and, in turn, produces many the each fuel element in the reactor core.
useful products like heat, neutrons and radioisotopes. 3. Fuel state
Mechanism of heat production. Most of the (i) Solid (ii) Liquid
energy is imparted to the two fission fragments into which (iii) Gas
the nucleus divides causing them to move at high speed. The nuclear fuel is available in three states—solid,
However, because they have taken birth in a dense mass liquid and gas. In reactors the fuel is mostly used in solid
of metal, they are rapidly slowed down and brought to rest state or in the form of solution dissolved in water. The liquid
by colliding with other atoms of the metal. In so doing,
metal reactors are in practical use.
their energy is converted into heat in much the same way
as energy given up by a slowing motor can be converted 4. Fuel material
into heat in the brake lining. In this way, the mass of (i) Natural uranium with U235 contents (occurs in
uranium metal gets heated up. nature)
(ii) Enriched uranium with more than 0.71 of U235
7.3.2. Classification of Nuclear Reactors
(iii) Pu239, Pu241 or Pu239 (man made)
Nuclear reactors are classified according to the chain
reacting system, use, coolants, fuel material etc. (iv) U–233 (man made)
NUCLEAR POWER PLANT 407
Considering the necessary requirement of fission material. By-products are the same as those of power
process and its availability economically the fuels used in reactors.
reactors are uranium, plutonium and thorium. U235 is easily Production reactors. The output of such reactors
available in natural uranium (i.e., 0.7%) and its content is radioactive materials which are used as sources of
increases upto 90% in enriched uranium. radiation and tracers in research in all areas of science.
5. Moderator By-products are the same as those of power reactors.
(i) Water (H2O) 7. Coolant
(ii) Heavy water (D2O) (i) Air, carbon or helium cooled reactors
(iii) Graphite (ii) Water or other liquid cooled reactors
(iv) Beryllium or beryllium oxide (iii) Liquid metal cooled reactors.
(v) Hydrocarbons or hydrides. In gas-cooled reactors the amount of gas required to
A moderator’s function is to absorbs the part of the extract the heat is too much and therefore these reactors
kinetic energy of the neutrons. The neutrons collide directly are expensive. Gases have poor heat carrying capacity. CO2
with the moderator and thus slowed down. No ideal and He have been used in the early reactors. Mostly water
moderator is available in nature or has been produced is used as a coolant.
artificially. The light weight nuclei materials are not suited Liquid metal cooled reactors are also suitable as the
at all as a moderator because they do not possess the metal is having high boiling point and low steam pressure.
property of absorption of neutrons. These are the power reactors.
Light water, heavy water and graphite are the most 8. Construction of core
common moderators used in reactors. (i) Cubical (ii) Cylindrical
6. Principal product (iii) Octagonal (iv) Spherical
(i) Research features to produce Research reactors (v) Slab (vi) Annulus.
neutrons The proper shape to the core is given on the practical
(ii) Power reactor to produce heat Power reactors consideration and can have cubical, cylindrical or ring type
(iii) Breeder reactors to produce Breeder reactors construction.
fissionable materials 7.3.3. Essential Components of a Nuclear Reactor
(iv) Production reactors to Production reactors
The essential components of a nuclear reactor are as
produce isotopes follows :
Research reactors. These are designed to produce 1. Reactor core
the high neutron flux for research work and these neutrons 2. Reflector
are used to determine the neutron properties of interaction
3. Control mechanism
with the nuclei and the effect of bombardment of neutrons
4. Moderator
on the materials. The reactors are operated at high neutron
flux and low power level otherwise the cooling will be a 5. Coolants
problem. The unit is cooled constantly during operation. 6. Measuring instruments
The by-products are heat and fission products which are 7. Shielding.
removed during operation. 1. Reactor core :
Power reactors. In these reactors the energy is The reactor core is that part of a nuclear power
produced in heat form which is carried away to the heat plant where fission chain reaction is made to occur and
exchanger by circulating the coolant through the reactor where fission energy is liberated in the form of heat for
and heat exchanger. In the heat exchanger the coolant operating power conversion equipment. The core of the
converts the water into steam to run the turbine. The by- reactor consists of an assemblage of fuel elements, control
products are fission products, neutrons and other radiation rods, coolant and moderator. Reactor cores generally have
particles. a shape approximating to a right circular cylinder with
These reactors are useful to produce huge amount diameters ranging from 0.5 m to 15 m. The pressure
of power and are widely used in power plant stations. In vessels which houses the reactor core is also considered
such reactors consumption is very low. a part of the core (Fig. 7.7). The fuel elements are made
of plates or rods of uranium metal. These plates or rods
Breeder reactors. A breeder reactor converts fertile
are usually clod in a thin sheath of stainless steel,
materials into fissionable materials such as U238 and Th232
zirconium or aluminium to provide corrosion resistance,
to Pu239 and U233 respectively besides the power production. retention of radioactivity and in some cases, structural
It is worth noting that the amount of fissionable material support. Enough space is provided between individual
produced is more than its consumption of fissionable plates or rods to allow free passage of the coolant.
408 POWER PLANT ENGINEERING
4. Moderator :
In a nuclear reactor the function of a moderator is :
(i) To slow down the neutrons from the high
velocities and hence high energy level, which they have on
Fig. 7.7. Nuclear reactor.
being released from the fission process. Neutrons are
2. Reflector : slowed down most effectively in scattering collisions with
A reflector is usually placed round the core to reflect nuclei of the light elements, such as hydrogen, graphite,
back some of the neutrons that leak out from the surface beryllium etc.
of the core. It is generally made of the same material as (ii) To slow down the neutrons but not absorb them
the moderator. The desirable properties of a moderator in a reactor
3. Control mechanism : are :
It is an essential part of a reactor and serves the 1. High slowing down power.
following purposes :
2. Low parasite capture.
(i) For starting the reactor i.e., to bring the reactor
3. Non-corrosiveness (or corrosiveness resistance).
up to its normal operating level.
4. Machinability (if solid).
(ii) For maintaining at that level i.e., keep power
production at a steady state. 5. High melting point for solids and low melting
(iii) For shutting the reactor down under normal or point for liquids.
emergency conditions. 6. Chemical and radiation stability.
The control system is also necessary to prevent the 7. High thermal conductivity.
chain reaction from becoming violent and consequently 8. Abundance in pure form.
damaging the reactor. The effective multiplication factor H2O, D2O (heavy water), He (gas), Be and C
of the reactor is always kept greater than unity in order (graphite) are the commonly used moderators.
that the number of neutrons keeps on increasing in
As a moderator D2O is the best material available
successive generations. As the number of neutrons and
(moderating ratio of D2O is 12000 as compared to 72 for
hence the neutron flux density increases, the temperature
also increases. Unless the growth is checked at some point, H2O and 170 for carbon) because (i) it has excellent neutron
the reactor is likely to be damaged as a result of too rapid slowing properties, (ii) it has very small cross-section for
liberation of energy. neutron capture, (iii) it can be used as a coolant as well. Its
disadvantages are : (i) it has low boiling point so that it
Note. The control system works on the simple principle necessitates pressurisation, (ii) it is very expensive. But, the
of absorbing the excess neutrons with the help of control
advantages of D2O as moderator or moderator coolant
rods either made of boron steel or cadmium strips. Both
these materials have very large cross-section for thermal outweigh its high cost.
neutrons i.e., they are very good absorbers of slow neutrons 5. Coolants :
and also have the advantage of not becoming radioactive The function of a coolant is to remove the intense
due to neutron capture. By pushing these rods deeper into
heat produced in the reactor and to bring out for being
the central core, any amount of excess neutrons can be
absorbed. Once the reactor has reached pre-determined utilised.
NUCLEAR POWER PLANT 409
Reactor core
Turbine
9. High specific heat (reduces pumping power and Heat
thermal stresses). exchanger
10. High density (reduces pumping power and
physical plant size).
Commonly used coolants : Santiwax R (organic, Hg,
He, CO2) (b)
The most widely-used gaseous coolant is CO2 Steam
particularly in large-power reactors. It is (i) cheap, (ii) does
not attack metals at reasonable temperatures, and (iii) has
small cross-section for neutron capture. Reactor Turbine
core
Some possible reactor cooling systems :
Some possible reactor cooling systems are illustrated
schematically in Figs. 7.8, 7.9 and 7.10.
Coolant
(c)
Steam
Fig. 7.9. Water cooled reactors : (a) Swimming-pool
reactor ; (b) Pressurised-water reactor ; (c) Boiling water reactor.
Liquid metal
Biological
Steam
shield
Water
Reactor core Heat exchanger
(Solid fuel)
(a)
Water
Liquid fuel
Steam
Reactor core Primary Secondary
heat exchanger heat exchanger
(ii) protect operating personnel from exposure to Now, NV = Total number of fissile nuclei in the
radiation. reactor fuel
The first known as thermal shield is provided = m × 6.02 × 1026/235
through the steel lining, while the other called external or where m is the mass of the U235 fuel. It is known that fission
biological shield is generally made of thick concrete cross-section of U235 for thermal neutrons is 582 barns =
surrounding the reactor installation. 582 × 10–28 m2.
Among the nuclear radiations produced in a reactor
3.2 1011 nu 582 1028 m 6.02 1026
the alpha and beta particles, thermal (slow) neutrons, fast P=
neutrons and gamma rays are harmful ones and must be 235
–12
= 4.77 × 10 m nu watt
shielded against. Of these only the fast neutrons and
gamma rays present some serious difficulty in designing ~ –12
4.8 × 10 mnC watt.
the reactor shielding, since alpha and beta particles can
be stopped by a fraction of an inch of a solid substance, 7.4. MAIN COMPONENTS OF A
while thermal neutrons can be automatically guarded NUCLEAR POWER PLANT
against with a shield thick enough to provide protection
Fig. 7.11 shows schematically a nuclear power plant.
against fast neutrons and gamma rays.
The effectiveness of a nuclear shield against gamma Hot coolant Steam
rays approximately depends upon its mass. A heavy material Reactor Steam
Generator
like lead will be a more effective shield per unit weight, core Turbine
than a light element such as carbon. On the other hand, Steam
Reactor
unusual core design, using both natural and highly 5. There is a complete freedom to inspect and
enriched fuel. The principal parts of the reactor are : maintain the turbine, feed heaters and condenser
1. Pressure vessel during operation.
2. Reactor thermal shield 6. This reactor allows to reduce the fuel cost
3. Fuel elements extracting more energy per unit weight of fuel
as it is ideally suited to the utilisation of fuel
4. Control rods
designed for higher burn-ups.
5. Reactor containment
6. Reactor pressuriser. Disadvantages :
The components of the secondary system of 1. Capital cost is high as high primary circuit
pressurised water plant are similar to those in a normal requires strong pressure vessel.
steam station. 2. In the secondary circuit the thermodynamic
Refer to Fig. 7.12. In PWR, there are two circuits of efficiency of this plant is quite low.
water, one primary circuit which passes through the fuel 3. Fuel suffers radiation damage and, therefore its
core and is radioactive. This primary circuit then produces reprocessing is difficult.
steam in a secondary circuit which consists of heat 4. Severe corrosion problems.
exchanger or the boiler and the turbine. As such the steam 5. It is imperative to shut down the reactor for fuel
in the turbine is not radioactive and need not be shielded. charging which requires a couple of month’s time.
The pressure in the primary circuit should be high so that 6. Low volume ratio of moderator to fuel makes fuel
the boiling of water takes place at high pressure. A element design and insertion of control rods
pressuring tank keeps the water at about 100 kgf/cm2 so difficult.
that is will not boil. Electric heating coils in the pressuriser
7. Fuel element fabrication is expensive.
boil some of the water to form steam that collects in the
dome. As more steam is forced into the dome by boiling, its 7.5.2. Boiling Water Reactor (BWR)
pressure rises and pressurises the entire circuit. The
In a boiling water reactor enriched fuel is used. As compared
pressure may be reduced by providing cooling coils or
to PWR, the arrangement of BWR plant is simple. The plant
spraying water on the steam.
can be safely operated using natural convection within the
Pressuriser core or forced circulation as shown in Fig. 7.13. For the
Steam safe operation of the reactor the pressure in the forced
Water Generator circulation must be maintained constant irrespective of the
(Primary Turbine load. In case of part load operation of the turbine some steam
circuit) is by-passed.
Reactor
Heat exchanger
or boiler Condenser
Cooling Generator
Water water
Turbine
Water (Secondary circuit) Forced Steam
Reactor
circulating by pass
Circulating pump Feed pump Condenser
pump
Fig. 7.12. Pressurised water reactor. Cooling
water
Water acts both as coolant as well as moderator.
Either heavy water or the light water may be used for the
above purpose. Feed pump
A pressurised water reactor can produce only
saturated steam. By providing a separate furnace, the steam Fig. 7.13. Boiling water reactor.
formed from the reactor could be super-heated.
Advantages of BWR :
Advantages of PWR : 1. Heat exchanger circuit is eliminated and
1. Water used in reactor (as coolant, moderator and consequently there is gain in thermal efficiency
reflector) is cheap and easily available. and gain in cost.
2. The reactor is compact and power density is high. 2. There is use of a lower pressure vessel for the
3. Fission products remain contained in the reactor reactor which further reduces cost and simplifies
and are not circulated. containment problems.
4. A small number of control rods is required. 3. The metal temperature remains low for given
output conditions.
412 POWER PLANT ENGINEERING
4. The cycle for BWR is more efficient than PWR company. A few CANDU reactors are operating or under
for given containment pressure, the outlet construction in some other countries as well.
temperature of steam is appreciably higher in In this type of reactor the natural uranium (0.7%
BWR. U235) is used as fuel and heavy water as moderator. There
5. The pressure inside the pressure vessel is not reactors are more economical to those countries which do
high so a thicker vessel is not required. not produce enriched uranium, as the enrichment of
uranium is very costly.
Disadvantages :
CANDU (heavy water) reactor, differs basically from
1. Possibility of radioactive contamination in the light-water reactors (LWRS) in that in the latter the same
turbine mechanism, should there be any failure water serves as both moderator and coolant, whereas in the
of fuel elements. CANDU reactor the moderator and coolant are kept separate.
2. More elaborate safety precautions needed which Consequently unlike the pressure vessel of a LWR, the
are costly. CANDU reactor vessel, which contains the relatively cool
3. Wastage of steam resulting in lowering of heavy water moderator, does not have to withstand a high
thermal efficiency on part load operation. pressure. Only the heavy water coolant circuit has to be
pressurised to inhibit boiling in the reactor core.
4. Boiling limits power density ; only 3 to 5% by
Description of CANDU reactor
mass can be converted to steam per pass through
the boiler. Fig. 7.14 shows the schematic arrangement of a
CANDU reactor.
5. The possibility of “burn out” of fuel is more in
Reactor vessel and core. The reactor vessel is a
this reactor than PWR as boiling of water on the
steel cylinder with a horizontal axis ; the length and
surface of the fuel is allowed.
diameter of a typical cylinder being 6 m and 8 m
7.5.3. CANDU (Canadian-Deuterium-Uranium) respectively. The vessel is penetrated by some 380
Reactor horizontal channels called pressure tubes because they are
designed to withstand a high internal pressure. The
CANDU is a thermal nuclear power reactor in which heavy channels contain the fuel elements and the pressurised
water (99.8% deuterium oxide D2O) is the moderator and coolant flows along the channels and around the fuel
coolant as well as the neutron reflector. This reactor was elements to remove the heat generated by fission. Coolant
developed in Canada and is being extensively used in this flows in the opposite directions in adjacent channels.
Steam
turbine
Reactor Controls
vessel
Heavy water
coolant
Fuel charging
machine
The high pressure (10 MPa) and high temperature Advantages of CANDU reactor :
(370C) coolant leaving the reactor core enters the steam 1. Heavy water is used as moderator, which has
generator. About 5% of fission heat is generated by fast higher multiplication factor and low fuel
neutrons escaping into the moderator, and this is removed consumption.
by circulation through a separate heat exchanger. 2. Enriched fuel is not required.
Fuel. In a CANDU reactor the fuel is normal (i.e., 3. The cost of the vessel is less as it has not to
unenriched) uranium oxide as small cylinder pellets. The withstand a high pressure.
pellets are packed in a corrosion resistance zirconium alloy 4. Less time is needed (as compared to PWR and
tube, nearly 0.5 long and 1.3 cm diameter, to form a fuel BWR) to construct the reactor.
rod. The relatively short rods are combined in bundles of 5. The moderator can be kept at low temperature
37 rods, and 12 bundles are placed end to end in each which increases its effectiveness in slowing down
pressure tube. The total mass of fuel in the core is about neutrons.
97,000 kg. The CANDU reactor is unusual in that refueling Disadvantages :
is conducted while the reactor is operating.
1. It requires a very high standard of design,
Control and protection system manufacture and maintenance.
There are the various types of vertical control system 2. The cost of heavy water is very high.
incorporated in the CANDU reactor : 3. There are leakage problems.
— A number of strong neutron absorber rods of 4. The size of the reactor is extremely large as
cadmium which are used mainly for reactor power density is low as compared with PWR and
shut-down and start-up. BWR.
— In addition to above there are other less strongly, 7.5.4. Gas-Cooled Reactor
absorbing rods to control power variations
during reactor operation and to produce an In such a type of reactor, the coolant used can be air,
hydrogen, helium or carbon dioxide. Generally inert gases
approximately uniform heat (power) distribution
are used such as helium and carbon dioxide. The moderator
throughout the core.
used is graphite. The problem of corrosion is reduced much
In an emergency situation, the shut-down rods in such reactors. This type of reactor is more safe specially
would immediately drop into the core, followed, if necessary in case of accidents and the failure of circulating pumps.
by the injection of a gadolinium nitrate solution into the The thickness of gas cooled reactor shield is much reduced
moderator. as compared to the other type of reactor.
Steam system. Steam system is discussed below : There are two principal types of gas cooled reactors
— The respective ends of the pressure tubes are developed for centre station service and these are :
all connected into inlet and outlet headers. (i) The gas cooled, graphite moderator reactor
— The high temperature coolant leaving the (GCGM)
reactor passes out the outlet header to a steam (ii) The high temperature gas cooled reactor
generator of the conventional inverted U-tube (HTGC).
and is then pumped back into the reactor by Both types are graphite moderated. The former
way of the inlet header. (GCGM) uses natural uranium fuel while the latter (HTGC)
— Steam is generated at a temperature of about employs highly enriched uranium carbide mixed with
265C. thorium carbide and clad with graphite.
There are two coolant outlet (and two inlet) headers, The coolant pressure and temperature in GCGM are
one at each end of the reactor vessel, corresponding to the about 7 bar 336C respectively, for HTGC, there figures
opposite directions of coolant flow through the core. Each are 15 to 30 bar and 700C to 800C.
inlet (and outlet) header is connected to a separate steam Arrangement of high temperature, gas cooled
generator and pump loop. A single pressurizer (of the type reactor is shown in Fig. 7.15.
used in pressurised water reactors) maintains an Advantages of gas-cooled reactor :
essentially constant coolant system pressure. 1. The processing of the fuel is simpler.
The reactor vessel and the steam generator system 2. No corrosion problem.
are enclosed by a concrete containment structure. A water 3. As a result of low parasitic absorption it gives
spray in the containment would condense the steam and better neutron economy.
reduce the pressure that would result from a large break 4. Graphite remains stable under irradiation at
in the coolant circuit. high temperatures.
414 POWER PLANT ENGINEERING
5. The use of carbon dioxide as coolant completely 7.5.5. Liquid Metal Cooled Reactors
eliminates the possibility of explosion in the
Sodium-graphite reactor (SGR) is one of the typical liquid
reactor which is always present in water-cooled
plants. metal reactors. In this reactor sodium works as a coolant
and graphite works as moderator.
6. The uranium carbide and graphite are able to
resist high temperatures, and, therefore, the Sodium boils at 880C under atmospheric pressure
problem of limiting the fuel element temperature and freezes at 95C. Hence sodium is first melted by electric
is not as serious as in other reactors. heating system and be pressurised to about 7 bar. The
liquid sodium is then circulated by the circulation pump.
Primary circuit Steam circuit The reactor will have two coolant circuits or loops :
Generator (i) The primary circuit has liquid sodium which
Turbine circulates through the fuel core and gets heated by the
fissioning of the fuel. This liquid sodium gets cooled in the
Reactor
Heat
Condenser intermediate heat exchanger and goes back to the reactor
exchanger
vessel.
Cooling
water (ii) The secondary circuit has an alloy of sodium and
potassium in liquid form. This coolant takes heat from the
intermediate heat exchanger and gets heat from liquid
Condenser pump sodium of primary circuit. The liquid sodium-potassium
then passes through a boiler which is once through type
Fig. 7.15. Gas-cooled reactor.
having tubes only. The steam generated from this boiler
Disadvantages : will be superheated. Feed water from the condenser enters
1. Fuel loading is more elaborate and costly. the boiler, the heated sodium-potassium passing through
2. Power density is very low (due to low heat the tubes gives it heat to the water thus converting it into
transfer coefficient), therefore, large vessel is steam. The sodium-potassium liquid in the second circuit
required. is then pumped back to the intermediate heat exchanger
3. Since the critical mass is high therefore, large thus making it a closed circuit.
amount of fuel loading is initially required. The reactor vessel, primary loop and the
4. If helium is used in stead of carbon dioxide, the intermediate heat exchanger is to be shielded for radio-
leakage of gas is a major problem. activity. The liquid metal be handled under the cover of an
5. More power is required for coolant circulation inert gas, such as helium, to prevent contact with air while
(as compared with water-cooled reactors). charging or draining the primary or secondary circuit/loop.
6. The control is more complicated due to low The arrangement of a sodium-graphite reactor
negative coefficient as helium does not absorb (SGR) is shown in Fig. 7.16.
neutrons.
Generator
Turbine
Heat
Reactor exchanger Condenser
Cooling
water
Generator
Turbine
Reactor
Advantages of a breeder reactor : 3. Neutron flux is high at the centre of the core.
1. The moderator is not required. 4. The specific power of the reactor is low.
2. High breeding is possible. 5. There is a major problem of handling sodium as
3. Small core is sufficient (since it gives high power it becomes hot and radioactive.
density than any other reactor).
4. The parasite absorption of fuel is achievable. 7.6. SELEC TION OF MATERIALS FOR
5. High burn-up of fuel is achievable. REAC TOR COMPONENTS
6. Absorption of neutrons is low.
Some of the factors governing the selection of materials
Disadvantages : for the various reactor components are considered below :
1. Requires highly enriched (15 per cent) fuel. 1. Structural material :
2. It is necessary to provide safety against melt- The structural units implied are :
down. (i) The cladding material for fuel elements.
416 POWER PLANT ENGINEERING
(ii) Fuel element assemblies. Air has been used in some research reactors operating on
(iii) Containers for coolants, ducts, etc., in the core. open cycle with discharge to the atmosphere at a high level
(iv) Any general structure in the reaction zone. to minimise the effect of Ar. Helium is attractive but is
expensive. Gases involve high pumping cost.
Obviously the purely mechanical properties must be
adequate at the normal working temperature, and the Water. Water has better thermal properties than
material must be capable of the necessary fabrication and 1
gases and the pumping power is roughly th that for
working. 10
In case where liquids are involved, corrosion or gases operated at ten atmospheres pressure. Its moderating
erosion problems may be present. These may be especially properties may be usefully utilised when used as a coolant.
troublesome in aqueous homogeneous reactors or in It has a fairly large absorption cross-section, and undergoes
reactors employing liquid metals. decomposition by radiation. It is subjected to induced
radioactivity, and it has a corrosive action on metals, and a
From the standpoint of the nuclear physics the basic
low boiling point. Degasification may be necessary.
requirement is low neutron absorption cross-section. Since
For efficient power production high pressure
absorption cross-sections are less at high than at low
operation is necessary. This necessitates the use of a
neutron energy levels, a material which is entirely
pressure vessel to enclose the reactor. Boiling water
unsuitable at thermal energies may be acceptable in fast
reactors (BWR) in which the coolant serves also as a
reactors. In addition to the effect on the neutron economy
moderator show promise.
of the system, structural materials may become dangerous
Heavy water has a lower absorption cross-section
to handle due to induced radioactivity.
than natural water and its use leads to economy in fissile
Some structural materials are discussed below : material. If it were cheaper it would be attractive for use
Aluminium. In a very pure state it is being in boiling water type reactor.
extensively used as a cladding material for fuel elements. Liquid metals are of special interest in relation to
Magnesium. It is more costly and is difficult to reactors operating at high thermal flux. Their main
work. disadvantage is in difficulty of handling, and in their
Beryllium. It offers advantages in that it would corrosive properties. Their heat transfer properties are better
serve also as a moderator but it is again costly and difficult than those of water, but their volumetric heat capacity is
to work. not as good, so that the pumping power may be greater or
less than that of water. Sodium is the most favoured at
Zirconium. It is a comparatively new material
present, for if free from oxygen it does not attack stainless
commercially, but offers considerable promise. It is steel, nickel and nickel alloys, beryllium or graphite at
extremely corrosion resistant at low temperatures, but less temperatures below 600°C.
so above 400C. Its mechanical properties are also impaired
3. Moderators and reflectors :
above this temperature. In the intermediate cross-section
Possible materials for use as moderator and
range titanium has a very good strength/weight ratio from
reflectors are :
100 to 450C and is corrosion resistant to aqueous solutions
of high temperatures. (i) Ordinary and heavy water
Alloys. Silicon steels may be used in some fast (ii) Beryllium
reactors, but considerable care is needed in their heat (iii) Beryllia
treatment. (iv) Graphite.
A number of nickel alloys are of interest and offer Ordinary water has excellent slowing down
considerable resistance to attack by fused salts and alkali properties for neutrons, but unfortunately, neutron capture
hydroxide. is also high. This means that enriched uranium fuel is
required in ordinary water moderated reactors, but the
Silicon, of absorption cross-section 0.1 barn and tin,
small migration length still permits a reactor of relatively
absorption cross-section 0.6 barn, might prove useful for
small size. Some of disadvantages of water are (i) attendant
alloying with other material.
corrosion problems, (ii) its relatively low boiling point, and
2. Reactor coolants : (iii) decomposition by nuclear radiations, resulting in the
Gaseous coolants. There coolants have much to liberation of oxygen and hydrogen which may require to
recommend them from the standpoint of general radiation be recombined in ancillary plant. The low boiling point
and thermal stability and ease of handling. Gases are poor, requires the use of a pressure vessel when high
however, from the standpoint of heat transfer and at high temperatures are involved.
temperatures some of them, for example oxygen and Heavy water is an excellent moderator and has a high
hydrogen, may attack other materials present in the core. moderating ratio compared with the other materials.
NUCLEAR POWER PLANT 417
Beryllium. The nuclear properties of beryllium are Thermal shield. Every absorption in a shield is
eminently suitable, but it is expensive, brittle and difficult roughly exponential. Thus 90% of the radiation is absorbed
to fabricate and is corroded by water. in the first 10% of the thickness. This results in considerable
Graphite. It has been used most extensively as a liberation of heat. For this reason that part of the shield
reactor moderator despite the fact that its moderating nearest to the core is usually of iron in thickness 5 to
properties are not as good as heavy water or beryllium. 10 cm which may be air-cooled. This part of the shield is
However, (i) it is reasonably cheap, even when the necessary referred to as the ‘thermal shield’.
high degree of purity is achieved, (ii) it has good mechanical Summary of Materials for Nuclear Power Reactors
properties and thermal stability, and (iii) is a good conductor Structural :
of heat. (i) Aluminium (ii) Stainless steel
Its chief disadvantages are the possibility of reaction (iii) Nickel alloys (iv) Zirconium
with air at high temperatures and its relatively low
(v) Magnesium
mechanical strength.
Fuel :
4. Fuel :
(i) Uranium (ii) Uranium ceramics
The proportion of the fissile material in the fuel is
of considerable importance in determining the critical size (iii) Thorium (iv) Thorium oxide
of the reactor. This is because the ratio of fissile to non- Coolant :
fissile material in the fuel determines the neutron economy (i) Water (ii) Liquid metals
at the source. The following table gives the average number (iii) Sodium, potassium (iv) Mercury
of neutrons liberated per neutron absorbed in the fuel. (v) Lead bismuth (vi) Gases
Neutron type U235 Pu239 Natural uranium
(vii) Helium (viii) Nitrogen
Thermal 2.11 1.95 1.32
(ix) Carbon dioxide
Fast 2 2 1
Control :
5. Shielding and radiation protection :
(i) Boron steel (ii) Cadmium
Protection of personnel is achieved partly by the use
(iii) Samarium oxide (iv) Gadolinium oxide
of remote control and, in some cases, the provision of a
pressure vessel to contain the fission products which might Mederator reflector :
result from an accident. However, shielding of the reactor (i) Water (ii) Heavy water
itself is invariably required. (iii) Beryllium (iv) Beryllium oxide
A biological shield must slow down the fast neutrons (v) Graphite (vi) Metal hydrides
leaving the core of the reactor, must capture the slowed Shielding :
down neutrons and must absorb all gamma and similar (i) Water (ii) Cement and concrete
radiation produced. It must be borne in mind that neutron
(iii) Iron (iv) Lead
capture in the shield itself may give rise to further gamma
radiation. A combination of light (moderating or slowing (v) Tantalum (vi) Bismuth
down) and heavy elements is the best. The latter reduces (vii) Boron.
the energy of very fast neutrons by inelastic scattering.
The incorporation of a good neutron absorber (e.g. boron 7.7. METALS FOR NUCLEAR ENERGY
10) is beneficial. Cadmium is not particularly suitable since Several metals such as uranium, thorium and plutonium
it emits high energy photons, with energies of the order are used for nuclear energy. The most important among
7.5 MeV. The heavy elements may be metallic iron or lead, them is Uranium. These metals are discussed below :
or iron oxide or barytes. The light element is usually
1. Uranium :
hydrogen in the form of water, often combined in concrete,
but in research reactors in particular, possibly as water. A Occurrence :
homogeneous arrangement of heavy and light elements is The following are the important ores :
best, for example, the use of a laminated construction or (i) Uranite UO2 (contains Th, rare earths)
the use of iron concrete. The latter consists of iron mixed in (ii) Pitchblende UO2+x
barytes concrete, or alternatively limonite (iron ore) is used (iii) Carnotite K2 (UO2)2(VO4)2x . H2O.
partially to replace barytes in the mix.
418 POWER PLANT ENGINEERING
7.9. NUCLEAR-PLANT SITE SELECTION unparalleled nuclear plant safety record. Most plants built
to date have not been in or near heavily populated areas.
Nuclear power plants must meet all the economic and 2. Population distribution :
technical and most of the legal criteria that apply to the Since power reactors must be located reasonably
siting of conventional fossil-fuel-fired power plants. In close to load centers, the population distribution around
addition, the importance of site characteristics in the the site is a necessary consideration in the evaluation of a
assessment of public safety results in greater concern in nuclear power-plant site. The distances, the site
siting nuclear plants than with any other type of industrial meteorological conditions and the amount of radioactive
facility. Of particular concern are the population material which could be released from the plant during a
distribution with respect to the site and the natural factors major accident are used to evaluate the suitability of the
which could affect the transport of radioactive material to site from the standpoint of safety to the public. In addition
the public, under normal operating conditions and in the to the permanent population surrounding a site, it is also
highly unlikely event of an accident which could release necessary to consider part-time peaks in population, such
radioactive material to the environment. as during the day or on weekends in recreational areas,
The various factors to be considered while selecting and seasonal variation in population, particularly in resort
the site for a nuclear power plant are enumerated and areas. Consideration also should be given to estimates of
described in detail below : future increases or changes in population distribution.
1. Proximity to load centre To permit placing nuclear plants in desirable
2. Population distribution locations, it is necessary to provide effective engineered
3. Land use 4. Meteorology safeguard features to offset, at least in part, the present
5. Geology 6. Seismology requirement for large distances from population centers.
The trade-off between distance requirements and
7. Hydrology.
engineered safeguards is qualitative, and there are no
1. Proximity to load center : established rules or principles by which such a trade-off
Electrical power can be transmitted over can be factored into the evaluation of possible sites for a
considerable distances by power-transmission lines, but, nuclear power plant. Such a trade-off can, at present, be
because of the capital cost of the lines and rights-of-way based only on engineering judgement and on precedents
and transmission losses, an economic penalty is incurred established in the siting of other nuclear plants having
which increases with increasing distance between the different degrees of safeguards and located at various
generating station and the load center. It is apparent, distances from population centers.
therefore, that the closer the power-plant site can be located 3. Land use :
to the load center (while meeting other requirements such
The use to which the land surrounding a nuclear-
as reasonable land cost, adequate cooling water, local zone
plant site is being put, even though it may not be densely
restrictions, accessibility for fuel shipment, etc.), the lower
populated, may have an effect on the suitability of the site
can be the cost of power delivered to the consumer. Although
for a nuclear plant. For example, if land is used for
nuclear plants should be built close to their load centers,
agriculture, ingestion of food which has been contaminated
regulatory bodies have been very cautious, despite the
by fallout after an accident might conceivably result in a
NUCLEAR POWER PLANT 421
greater radiation dose to the public than might be received for nuclear plants, because of the implications for public
from direct exposure to radioactive materials transported safety, is the possibility of sudden earth movement which
downwind from the plants. Of similar concern, but possible could severely damage the plant. Earth slides due to soil
as a result of normal operation, is the chance that certain instability, subsidence due to consolidation of subsurface
marine life, stationary shellfish in particular, can materials or to removal of oil or water from subsurface
concentrate the small quantities of radioactivity normally formations, and ground displacements during earthquakes
released into the cooling water discharged from the plant. along geologic faults traversing the site—each receives very
Over a long period of time, the concentration of radioactivity careful consideration.
conceivable could build up to levels approaching maximum If the possibility exists for releasing radioactive
permissible concentrations. liquids from the plant, the ion-exchange and filtering
4. Meteorology : characteristics of the surrounding soil may be important.
Because the atmosphere is the principal means by If the soil could reliably retain any radioactivity released
which radioactivity released from a nuclear plant might and prevent it from entering water sources or otherwise
be transported to the public, site meteorological conditions coming in contact with persons or animals, the site would
are considered in selecting a nuclear plant site. Meteorology be that much more favourable.
is of concern both for normal discharges of gaseous 6. Seismology :
radioactive wastes and for the much less likely releases of Seismology is of particular concern is areas of high
larger quantities of airborne radioactive material which seismic activity because of the possibility that the forces
might result from an accident. A number of meteorological which can be produced by earthquakes could be sufficient
variables are normally evaluated for the site to determine to damage the reactor system and rupture the containment
appropriate atmospheric dilution factors. Among these structure. Careful consideration is given to the general
variables are : wind-direction frequencies, in conjunction seismic history of the area, including a description of all
with the population distribution ; wind velocities and the earthquakes which have been observed at the site, their
frequencies of each velocity increment ; frequency and magnitude or intensity, and the frequency spectrum for
duration of calms ; atmospheric lapse rate ; frequency and which structures should be analyzed. The proximity of the
duration of inversion conditions. Atmospheric dilution is site to known active faults must be determined, and any
increased, and thus the meteorological conditions are more significant faulting at or near the plant site must be
favourable, the more unstable the atmosphere and the evaluated. Conservative earthquake design factors, usually
greater the wind velocity. substantially greater than those required by the Uniform
Other meteorological conditions of concern are the Building Code, are used for critical equipment and
following : precipitation, since it may significantly increase structures in areas of high seismic activity.
deposition of radioactive materials from the atmosphere, In coastal areas the possibility of tsunamis may have
i.e., “rain-out” ; possible effects of topography on the local to be considered. These earthquake-generated sea waves
meteorology ; seasonal variations in meteorological may travel long distances very rapidly and, under certain
conditions ; and the frequency and severity of storms, shore conditions, can build up to substantial heights.
particularly tornadoes and hurricanes, which could severely Standard seismic design is generally adequate to meet the
damage the plant. Meteorological information collected at design criteria based on the factors described above, and
the plant site provides the greatest assurance that it is with the conservative design factors ordinarily used, reactor
representative of actual site conditions, provided that systems are adequate for even worse conditions than could
sufficiently accurate instrumentation is used and the data be realistically expected to occur.
are collected over a long enough period of time to be 7. Hydrology :
statistically valid. Usually the only meteorological
An important consideration is selecting a site for
information available during selection and evaluation of a
any power plant is the local hydrology. Present-day type of
site is data collected at the locations in the same general
nuclear plants require substantially greater quantities of
area, over a long period of time.
cooling water than do modern fossil steam plants because
At sites where meteorological conditions are of their higher turbine heat rates. In areas of limited water
particularly favourable or unfavourable, more careful supply, cooling towers can be used but at some cost penalty.
consideration would be given to meteorological An additional consideration for nuclear plants is that there
characteristics. be sufficient water flow for the discharge of low-level
5. Geology : radioactive liquid wastes. This usually imposes no
Investigation of the site geology is necessary to limitation because of the small quantities of wastes to be
determine the bearing capacity of the soil and the types of discharged and because it is possible to dilute or clean up
foundations which must be used for the major portions of the wastes to nearly any required concentration. If
the plant. Test borings are usually made for this purpose, necessary, it is possible to collect and ship these wastes off
just as for any other large structures. Of particular concern site.
422 POWER PLANT ENGINEERING
Another area of concern is the possibility of flooding, redetermination of total system costs. Simplified analysis
which could cause damage to the plant and equipment and requires the assumption of an immediate load availability
cause plant shutdown. Seismic sea waves and hurricanes to the new plant at the expense of load availability to the
may increase the possibility of flooding at coastal sites. older existing plants. Although more complicated, a system
Seiches (Periodic surface oscillations) could result in analysis using the lowest system incremental loading cost
flooding adjacent to large, enclosed bodies of water. The will provide a more accurate picture of real annual unit
flooding history of the site must be determined to permit costs for the various alternatives considered.
adequate site evaluation and plant design. 1. Capital costs :
The characteristics of the ground water and the level Capital costs are those costs which occur only once
of the water table at the site must be evaluated to ensure and are usually limited to the costs of procurement and
that contamination of local water sources by the discharge construction of the facilities prior to the time of commercial
of liquid radioactive wastes does not occur. It there is any operation. These are normally “capitalized” ; i.e., they are
possibility of significant discharge of radioactive treated as an investment which is depreciated over the useful
contamination to ground water, the absorption life of the plant rather than being treated as an annual or
characteristics of the soil and the drainage characteristics other shorter-term operating cost.
of the ground water, including its depth and estimated Determination of those costs which may be allowed
direction of flow, and the characteristics of wells in the within the capital-cost structure often depends on review
area may have to be determined as part of the site by the appropriate public-utility commission or other
evaluation. regulatory body and on corporate accounting policies.
Allocation of the capital-cost items over the life of the plant
7.10. APPLICATION OF NUCLEAR POWER is normally accomplished by applying factors, or percentage
PLANTS rates, which will account for depreciation, return on
investment, and taxes applied to income and property value.
A nuclear power station is ideally suited under the following The product of the total of these factors and the allowable
situations : capital costs gives the annual fixed charge per year for the
(i) In an area with potential for industrial capitalized investment. Within this structure, several
development, but limited conventional power resources, different depreciation methods are used, such as sinking
nuclear power generation appears as an only alternative. fund, straight-line depreciation, etc., depending upon the
(ii) If the existing power grid is to be firmed up or accounting structure already in existence.
additional power demand is to be met while all available 2. Fuel costs :
hydro power resource have been exploited, and coal is scarce
Fuel cycle. An understanding of nuclear-fuel costs
or expensive to transport, a nuclear power station may be
requires an understanding of the nuclear-fuel cycle, since
used with advantage.
the fuel-management programmes are significantly
different from those used for fossil-fueled plants.
7.11. ECONOMICS OF NUCLEAR POWER
Fig. 7.18 shows the basic fuel cycle. The word “cycle”
PLANTS
is intentionally used, for, unlike fossil fuels, a single pass
Typically, all costs of nuclear power plants are broken down through the reactor does not consume all the nuclear fuel.
into the following categories : Further, a valuable new fuel, plutonium, is generated
1. Capital costs (total). during power production.
2. Fuel costs (per year). Fuel costs are affected by the number of functional
3. Other operating and maintenance costs (per year). services which must be performed on the uranium fuel to
With a knowledge of these total and annual costs, prepare if for use, the additional services which must be
and a knowledge of the pertinent factors relating to performed to recover the “ash” value of the spent fuel, and
production, anticipated plant life, and the costs of invested the variation in the design data for each batch of fuel
money, unit costs may be determined for any time period employed.
desired. The calculation of nuclear-fuel costs using various
Although such unit costs may be determined on a data is particularly complex if a high degree of
single plant basis, it should be noted that the addition of
sophistication is desired, such as in the evaluation of
any new plant will normally provide excess capacity in the
competitive fixed-price bids or in the determination of
system under study. Thus, a more valuable analysis
involves the inclusion of the additional costs incurred by minimum incremental operating costs between two or more
the new plant in the total system cost pattern and the plants. However, for project scoping purposes and general
NUCLEAR POWER PLANT 423
1 Uranium ore
Mining 2 Uranium concentrate
3 Refined uranium as UF6
1 4 Slightly enriched uranium as UF6
Ore extraction Atomic power plant 5 Slightly enriched uranium dioxide
in powder or pellet form
2 6 Fabricated fuel assemblies
Conversion to 7 Spent fuel
enrichment 6 7
chemical form 8 Recovered uranium and plutonium
fuel materials
3
Chemical 9 Recycled uranium as UF6
Enrichment Fabrication recovery 10 Recycled plutonium and possibly
uranium in fuel chemical form
5 10 8
9 X Depleted uranium
4
Conversion to "tails" to storage
X fuel chemical form Y Z Reconversion
Y Radioactive waste con-
10
9 centrates to storage
Z Useful radio isotopes
other than fuels
familiarization with the principles involved, the following 8. Divide item 6 by item 7 to give the unit costs.
simplified method may be used to determine equilibrium The results of such simplified calculations are likely
fuel-cycle costs : to be somewhat low, since they do not recognize the various
1. Determine the initial uranium-procurement unit minor material losses. However, they are also not likely
cost in rupees per kilogram of uranium. This cost will vary accurately to reflect the true investment costs, since the
with the price of uranium yellow cake, the cost of converting investment value is a complex value varying with energy
it to uranium hexafluoride, and the cost of toll enrichment. production.
This latter item is, in turn, dependent upon the enrichment The complications inherent in a complete fuel-cycle
required (which determines the amount of separative work cost, coupled with the need to compute costs over an
required) and the unit cost of separative work. extended period involving changing cost patterns and also
2. Determine the fabrication unit cost, in terms of over the several fuel loadings required to reach an
rupees per kilogram, of combined uranium. equilibrium fuel-flow requirement, have led to the
3. Determine the spent-fuel-element shipping, development of computerized calculational methods.
reprocessing, and reconversion costs in terms of rupees per 3. Operations and maintenance costs :
kilogram of contained uranium. Operating and maintenance costs categories fall in
4. Determine the credit available for the recovered the following groups :
uranium and plutonium. (i) Labour
5. Determine the indirect costs, i.e., return on (ii) Materials, supplies and services
investment and provision for applicable taxes, by
(iii) Insurance
determining the average investment level throughout the
(iv) Fuel management
procurement period, energy-production period, and spent-
fuel recovery period and multiplying by the appropriate (v) Working capital.
interest of fixed-charge rates. (i) The plant staff required is relatively independent
6. Sum items 1 through 5 to give the total unit costs, of plant size, typically running 60 to 70 men, including all
in terms of rupees per kilogram of uranium. supervision, technical assistance, operations, maintenance
and miscellaneous supporting services. The costs for this
7. Determine the unit energy production, based upon
staff may vary substantially, being highly dependent upon
the average fuel energy production (usually given in terms
the local labour market and the labour costs.
of megawatt-days thermal per metric ton of uranium) and
the thermal efficiency of the plant. (ii) Materials, supplies, and services are also
relatively insensitive to plant size, although certain items
424 POWER PLANT ENGINEERING
are directly proportional to the thermal power level and shall have to be extremely careful in designing, constructing
the frequency and extent of power-level changes. and operating the nuclear power plants. The disaster in
(iii) Insurance costs may be divided into two Russia and elsewhere cannot be ignored easily.
component parts, property insurance and liability
insurance. Property insurance is normally a direct function 7.12. SAFETY MEASURES FOR NUCLEAR
of the capital value. POWER PL ANTS
(iv) Fuel-management services may be provided
In case of nuclear power plants the three main sources of
either by contracting for external services or by adding staff
radioactive contamination of the air are : (i) Fission of nuclei
to that already discussed. This cost is also essentially
of nuclear fuels, (ii) The effect of neutron fluxes on the heat
independent of plant size.
carries in the primary cooling system and on the ambient
Total Energy Costs. The total unit cost of energy
air, (iii) Damage of shells of fuel elements.
delivered at the bus bar is the sum of all of the preceding
cost components which are related to the energy-production The above, mentioned contamination of air can
period divided by the energy produced during the same cause health hazard to workers and community and
period. If escalation is disregarded, technological negative effect on surrounding forests. This calls for safety
improvements and lower fuel costs will tend to reduce this measures for a nuclear power plant, some of them are listed
value. below :
— From economical considerations, the Nuclear 1. A nuclear power plant should be constructed away
Power Plant are designed for 75% of the base from human habitation. An exclusion zone of 106 km radius
load. Fig. 7.19 shows the comparison of cost of around the plant should be provided where no public
production of power by thermal plants with the habitation is permitted.
cost of production by nuclear plants. 2. The materials to be used for the construction of a
nuclear power plant should be of required standards.
3. Waste water from nuclear power plant should be
purified.
4. The nuclear power plant must be provided with
such a safety system which should safely shut down the
plant as and when necessity arises.
Narora Atomic Power Project (NAPP) design entails
the following significant design improvements : (i) An
integral reactor vessel and end shield assemblies, (ii) Two
independent shut down systems, (iii) Total double
containment with suppression pool.
5. There must be periodic checks to ensure that
radioactivity does not exceed the permissible value is the
environment.
6. While disposing off the wastes from the nuclear
plants it should be ensured that there is no pollution of
Fig. 7.19. Comparison of costs between nuclear and thermal water of river or sea where these wastes are disposed.
power plants.
As can be seen, at low installed capacities, both the 7.13. NUCLEAR POWER PLANTS IN INDIA
capital investment and the energy cost per unit are less The various nuclear power plants situated in India are as
for thermal power plants. But when the installed capacity follows :
reaches 1000 MW, both the plants become comparable. 1. Tarapur power plant
Further, the increased cost of coal production and also the
2. Rana-Partap Sagar power plant
far flung coal mines will eventually make the nuclear power
3. Kalpakkam power plant
a cheaper one.
4. Narora power plant
In spite of the inevitability of our option to go nuclear
5. Kakrapar power plant.
for power production, the hazards are enormous and we
NUCLEAR POWER PLANT 425
Power plants
Particulars
Tarapur Rana-Partap Kalpakkam Narora Kakrapar
Sagar
7.14. FUTURE OF NUCLEAR POWER (iii) Safety of the nuclear plants. If the nuclear plants
are designed in such a way that they do not explode like a
India has hydro-power potential, and some coal reserves ; nuclear bomb they can give a safe operation, since they
unfortunately these are not very well distributed contain only a small amount of fissionable material
throughout the country. Moreover, most of the economically (as compared to 90% fissionable fuel in the atomic bomb
feasible hydropower schemes have already been developed. core).
The quality of Indian coal is not very good, and the reserves
are concentrated in one or two parts of the country. These 7.15. USEFUL BY-PRODUCTS OF NUCLEAR
reserves are also being depleted at a fast rate, the railways POWER GENERATION AND THEIR
consuming a large quantity. On the other hand, India has
adequate deposits of fissionable material-thorium, which USES
can eventually be used for generation of power. Therefore, The Nuclear plants supply many by-products like isotopes
development of nuclear power, to supply the growing which have many useful applications in our day-to-day life.
electricity demand of the country is quite logical and The fission products consist of Beta and Gamma
necessary. Thus the future of nuclear power is quite bright. emiting radioactive isotopes with different half-lives. Only a
The following three factors, however, need discussion : very small percentage of nucleon waste is used for industrial
(i) Cost of power generation. Although cost of power purposes. 90% of the nucleon wastes have short half-lives
generation in a nuclear power plant is comparatively more, and decay in a few years. It is the remaining 10% who have
yet with research in the nuclear technology the cost is bound centuries as half-lives which pose disposal problems.
to come down to a value comparable with that for Industrial isotopes must satisfy the following two
conventional plant. conditions :
(ii) Availability of nuclear fuel. The problem of (1) Yield of the isotope should be quite high.
availability of large amount of nuclear fuel can be overcome (2) The half-life should neither be too short nor too
to a great extent by switching over to breeder reactor in long.
which fissionable fuel is produced at the same time they Some of the Isotopes and their characteristics are
are consuming it. shown below :
Isotopes %Yield Half-life Type of Radiation
Beta MeV Gamma MeV
The radioactive isotopes are widely used in Biology, (9) Application in chemistry :
Medicine, Agriculture and Industries. Substances deteriorate when exposed to radiation
Industrial Applications : and the destroyed molecules are rejoined chemically to yield
new materials. This technique has been exploited in the
(1) Position location : Buried pipelines can be traced fields of polymerization, oxidation and halogenation
by using portable geiger Counters. processes.
(2) Flow patterns in pipes can be detected by In polymerization process, used in the
injecting radioactive isotopes into the flow. The radiation manufacturing of synthetic rubber and plastics, the
will be different for laminar and turbulent flows. elements react at high temperature and pressures. But by
irradiating the ingredients by Gamma radiation, the
(3) Leakage detection can be done by injecting
process can be carried out at 202C and atmospheric
isotopes into fluid in pipes. The reactivity will be different
pressure. This has helped in revolutionizing the polythene
at leakage points. industry.
(4) Ground water path is detected by mixing short (10) Sterilization of foods and drugs :
lived radioactive material with water (to avoid Bacteria are produced in food-stuffs and vegetables
contamination). and cause fermentation. Heating process can help in
(5) Thickness gauges. sterilization (complete destruction of Bacteria) and
pasteurization (90% destruction of Bacteria). But this
(6) Liquid level gauges.
heating process cannot be done for fruits, vegetables and
(7) Radiography (Flaw detection). drugs. For these items, irradiation is the process adopted
X-rays, which are having a high penetrating power to kill the bacteria. In this process, the materials are kept
are made to pass through castings, welds etc. and on the in an air-tight container and are subjected to Gamma
other side, the photographic plate receives the radiation. Radiation. After irradiation, these materials can be stored
at room temperature for longer durations.
The attenuation (reduced intensity) is a function of the
thickness of the test material and its density. Thus the (11) Direct electrical power generation :
film is exposed to varying intensities of radiation which Direct electrical power generation can be done in
devices called atomic battery.
help in detecting internal flaws of welds and castings.
(12) Tracer applications :
Co60 is a good source of Gamma rays and is cheaper
In this method, small dozes of isotopes of small half-
than X-ray tube and has a longer life. But this needs
lives are injected into reactants and then traced. This helps
constant heavy shielding whereas X-ray tube needs to trace the elements and their functions in the reactions.
shielding only during operation. Determining the role of sulphur in the vulcanization is one
(8) Density and content gauges : such example.
The Through Gauge is used for this purpose. If the In circuit breakers, the transfer of small amount of
reactivity is a function of density of the material and thus materials between the contact points can be detected by
this methods. Similarly, flows in the bonding of two
the density of the content can be measured. This method
materials and the flaws can be detected, as in the case of
is used in cigarette packing line and a relay arrangement
bonding between asphalt and stone.
is made to reject the faulty cigarettes.
WORKED EXAMPLES
Example 7.1. Calculate the following : Hence, fission rate for producing one watt of power
(i) The fission rate of U235 for producing a power of 1
one watt. = = 3.1 × 1010 fission/second. (Ans.)
3.2 1011
(ii) The energy released in the complete fissioning of (ii) One kg-atom of U235 i.e., a mass of 235 kg of U235
1 kg of U235. contains 6.02 × 1026 atoms (nuclides). Hence, energy
Assume that 200 MeV are released per fission of the released by 1 kg-atom of U235 is
uranium nucleus. = 200 × 6.02 × 1026 MeV
Solution. (i) Energy released per fission of U235 nuclide Energy released per kg of U235 is
= 200 MeV = 200 × 1.6 × 10–13 J
200 6.02 1026
= 3.2 × 10–11 J or W-s = MeV
235
NUCLEAR POWER PLANT 427
200 6.02 1026 1.6 1013 Now, 6.02 × 1026 atoms are contained in 235 kg of
= J U235.
235
= 8.2 × 1013 J. (Ans.) Hence, the mass which contains 7.5 × 1021 atoms is
Example 7.2. A nuclear reactor consumes 10 kg of U235 235 7.5 1021
per day. Calculate its power output if the average energy m= = 2.928 × 10–3 kg
6.02 1026
released per U-235 fission is 200 MeV. = 2.928 gm. (Ans.)
Solution. Quantity of U235 consumed per day = 10 kg Example 7.4. A power of 6 MW is being developed in a
Average energy released per U235 fission = 200 MeV nuclear reactor.
Number of atoms in 235 kg of U235 (i) How many atoms of U235 undergo fission per
= 6.02 × 1026 (Avogadro’s number) second ?
Hence, number of atoms contained in 10 kg of U235 (ii) How many kg of U235 would be used in 1000
6.02 1026 hours.
= × 10 = 2.56 × 1025 Assume that on an average 200 MeV is released per
235
Fission energy produced by these atoms fission.
= 200 × 2.56 × 1025 MeV Solution. Power being developed in the reactor = 6 MW =
6 × 106 W
= 200 × 2.56 × 1025 × 1.6 × 10–13 J
Average energy released per fission = 200 MeV
= 819.2 × 1012 J
(i) Number of atoms which undergo fission :
Time taken to consume 10 kg of U235
The fission rate for producing 1 watt = 3.1 × 1010
= one day = 24 × 3600 seconds
fissions/second (Refer to Example 7.1)
819.2 1012 Hence, fission rate for 6 × 106 W is
Power produced =
24 3600 = 3.1 × 1010 × 6 × 106 = 18.6 × 1016. (Ans.)
= 9.48 × 109 W. (Ans.) (ii) Mass of U235 consumed :
Example 7.3. During a 10-hour run from one station to Number of atoms (or nuclides) which would undergo
another, a railway engine develops an average power of fission in 1000 hours
1200 kW. If the engine is driven by an atomic power plant of
= 18.6 × 1016 × (1000 × 3600) = 6.696 × 1023
20% efficiency, how much U235 would be consumed on the
run ? Each U235 atom on fission releases 180 MeV of energy. Now, 1 kg-atom of U235 i.e., 235 kg of U235 contains
6.02 × 1026 nuclides, hence
Solution. Duration of the run between two stations =
10 hour Mass of U235 consumed
Average power developed by the railway engine = 235 6.696 1023
= = 0.2614 kg. (Ans.)
1200 kW 6.02 1026
Efficiency of the atomic power plant, = 20% Example 7.5. 200 MW of electrical power (average) is
Energy released by each atom of U235 = 180 MeV required for a city. If this is to be supplied by a nuclear
Mass of U235 consumed, m : reactor of efficiency 20 per cent, using U235 as the nuclear
fuel, calculate the amount of fuel required for one day’s
Energy consumed by the engine for the run
operation.
= 1200 × 10 = 12000 kWh
Assume that energy released per fission of U235
Since 1 kWh = 36 × 105 J nuclide = 200 MeV.
Energy consumed Solution. Average electrical power required by a city =
= 12000 × 36 × 105 = 432 × 108 J 200 MW = 200 × 106 W
Since the efficiency of atomic power plant is only Efficiency of the nuclear reactor, = 20%.
20%, energy required to produce it Amount of fuel required for one day’s
432 108 432 108 operation :
= = 216 × 109 J
0.2 Energy consumed by the city in one day
Energy produced per disintegration of U235 atom is = 200 × 106 × 24 × 3600 = 1728 × 1010 J
= 180 MeV = 180 × 1.6 × 10–13 J Since efficiency is 20%, energy required to be
Hence number of U235 atoms which must produced by the nuclear reactor is
disintegrate for producing 216 × 109 J is 1728 1010
= = 864 × 1011 J
216 109 0.2
= = 7.5 × 1021
180 1.6 10 13
428 POWER PLANT ENGINEERING
Binding energy per nucleon Example 7.11. A U235 nucleus is bombarded by a neutron,
127.88 resulting in its fission into Barium 137 and Krypton
= = 7.99 MeV. (Ans.)
16 97 nuclei. Write the complete nuclear equation and find the
Example 7.10. The half-life of Radon gas is 3.83 days. What amount of energy liberated in the reaction.
is its radioactive decay constant ? Solution. The nuclear reaction can be written as :
What percentage of the radon atoms originally 235 + 0n1 137 97
92U 56Ba + 36Kr +x
present will decay in a period of 45 days.
In a nuclear reaction, since the atomic numbers and
Solution. Let t1/2 = Half-life of radioactive nuclei,
mass numbers must balance on both sides of the equation
N = Number of radioactive nuclei present at any
therefore, the above equation is balanced with the addition
time t,
of a particle or particles having combined Z = 0 and A = 2
N0 = Initial number of such nuclei, and
to the products. Thus
= Proportionality constant (also known as
x = 20n1
radioactive decay constant).
From eqn. (7.7), the half-life is given as The complete nuclear equation becomes as :
235 + 0n1 = 56Ba137 + 36Kr97 + 2 0n1
0.693 92U
t1/2 = Mass before the reaction
= Mass of 235 + mass of 0n1
But t1/2 = 3.83 days ...(given) 92U
Radioactive decay constant, = 235.116 + 1.00898 = 236.125 a.m.u.
0.693 Mass after the reaction = Mass of Ba137 + mass of
= = 0.181 day–1
3.83 Kr97 + mass of two 0n1
From eqn. (7.4), = 136.9514 + 96.9520 + 2 × 1.00898
N = N0 e–t = 235.9214 a.m.u.
Here t = 45 days Thus, there is decrease in the mass after the reaction,
N = N0 × e–(0.181×45) = 0.00029 N0 so energy will be liberated.
%age of radon atoms those will decay in a period of The mass defect = 236.125 – 235.9214
45 days
= 0.2036 a.m.u.
N0 N N0 0.00029 N0
= × 100 = × 100 Energy released = 0.2036 × 933.75
N0 N0
= 99.971%. (Ans.) = 190.11 MeV. (Ans.)
HIGHLIGHTS
1. Those pairs of atoms which have the same atomic number (iv) Alpha particles : helium nuclei, charge + 2, mass 4.
and hence similar chemical properties but different atomic (v) Beta particles : electrons (charge – 1), positrons (charge
mass number are called isotopes. + 1), mass very small.
2. Those atoms which have the same mass number but
7. Half life represents the rate of decay of the radioactive
different atomic numbers are called isobars. Obviously,
isotopes. The half life is the time required for half of the
these atoms belong to different chemical elements.
parent nuclei to decay or to disintegrate.
3. Those pairs of atoms (nuclides) which have the same
atomic number and atomic mass number but have 8. Nuclear cross-sections (or attenuation co-efficients) are
different radioactive properties are called isomers and their measures of the probability that a given reaction will take
existence is referred to as nuclear isomerism. place between a nucleus or nuclei and incident rediation.
4. Those atoms whose nuclei have the same number of 9. It has been found that some materials are not fissionable
neutrons are called isotones. by themselves but they can be converted to the fissionable
5. The phenomenon of spontaneous emission of powerful materials, these are known as fertile materials.
radiations exhibited by heavy elements is called 10. Fission is the process that occurs when a neutron collides
radioactivity. The radioactivity may be natural or with the nucleus of certain of the heavy atoms, causing
artificial. the original nucleus to split into two or more unequal
6. The five types of nuclear radiations are : fragments which carry off most of the energy of fission as
(i) Gamma rays (or photons) : electromagnetic radiation. kinetic energy. This process is accompanied by the
(ii) Neutrons : uncharged particles, mass approximately 1. emission of neutrons and gamma rays.
(iii) Protons : + 1 charged particles, mass approximately 1.
430 POWER PLANT ENGINEERING
11. A chain reaction is that process in which the number of 15. The main components of a nuclear power plant are :
neutrons keeps on multiplying rapidly (in geometrical (i) Nuclear reactor
progression) during fission till whole the fissionable (ii) Heat exchanger (steam generator)
material is disintegrated. The multiplication or (iii) Steam turbine
reproduction factor (K) is given by : (iv) Condenser
No. of neutrons in any particular generation (v) Electric generator.
K=
No. of neutrons in the preceding generation 16. Some important reactors are :
If K > 1, chain reaction will continue and if K < 1, chain (i) Pressurised water reactor (PWR)
reaction cannot be maintained. (ii) Boiling water reactor (BWR)
12. Nuclear fusion is the process of combining or fusing two (iii) Gas cooled reactor
lighter nuclei into a stable and heavier nuclide. In this (iv) Liquid metal cooled reactor
case large amount of energy is released because mass of (v) Breeder reactor.
the product nucleus is less than the masses of the two 17. Following factors should be considered while selecting the
nuclei which are fused. site for a nuclear power plant :
13. A nuclear reactor is an apparatus in which nuclear fission (i) Proximity to load centre
is produced is the form of a controlled self-sustaining chain (ii) Population distribution
reaction. (iii) Land use (iv) Meteorology
14. Essential components of a nuclear reactor are : (v) Geology (vi) Seismology
(i) Reactor core (ii) Reflector (vii) Hydrology.
(iii) Control mechanism (iv) Moderator 18. Typically, all costs of nuclear power plants are broken
(v) Coolants (vi) Measuring instruments down into the following categories :
(vii) Shielding. (i) Capital costs (total) (ii) Fuel costs (per year)
(iii) Other operating and maintenance cost (per year).
THEORETICAL QUESTIONS
1. Explain the following terms : 10. Write a short note on ‘Fertile materials’.
(i) Atomic model (ii) Atomic mass unit 11. What do you mean by ‘Fission of nuclear fuel’ ?
(iii) Isotopes (iv) Isobars 12. What is a chain reaction ?
(v) Isomers (vi) Isotones. 13. What are the requirement of fission process?
2. What do you mean by the term ‘Radioactivity’ ? 14. How are the following defined ?
3. What is the difference between ‘Artificial radioactivity’ (i) Critical mass (ii) Critical size.
and ‘Natural radioactivity’ ? 15. What is ‘nuclear fusion’ ? How does it differ from ‘nuclear
4. Name five types of radiation of interest, in nuclear power fission’ ?
technology. 16. What is a nuclear reactor ?
5. Explain briefly the following : 17. How are nuclear reactors classified ?
(i) Prompt-fission gamma rays 18. Enumerate and explain essential components of a nuclear
(ii) Fission-product-decay gamma rays reactor.
(iii) Capture gamma rays 19. Explain with help of neat diagram the construction and
working of a nuclear power plant.
(iv) Activation gamma rays
20. What is a moderator ? Name common moderators and
(v) Inelastic scattering gamma rays. discuss their advantages and limitations.
6. Explain briefly the following types of neutrons : 21. Give the functions and materials for the following :
(i) Prompt-fission neutrons (i) Reflector (ii) Control rods
(ii) Delayed neutrons (iii) Biological shield.
(iii) Photoneutrons 22. Describe with the help of a neat sketch the construction
(iv) Activation neutrons working of a Pressurised Water Reactor (PWR). What are
(v) Reaction neutrons. its advantages and disadvantages ?
7. What do you mean by ‘Binding Energy’ ? What are the 23. What is ‘Boiling Water Reactor’ (BWR) ? How does it differ
total binding energy and binding energy per nucleon for from ‘Pressurised Water Reactor’ (PWR) ?
the 6C12 nucleus ? 24. Give the construction and working of a ‘Gas cooled reactor’.
8. Explain briefly the following terms relating radioactive What are its advantages and disadvantages ?
decay : 25. What is a ‘Liquid Metal cooled Reactor’ ? Explain briefly
(i) Activity (ii) Half life a typical liquid metal reactor.
(iii) Average (mean) life. 26. Describe a breeder reactor. What are its advantages and
9. What do you mean by the following : disadvantages ?
(i) Elastic scattering (ii) Inelastic scattering 27. What factors must be considered while selecting materials
(iii) Capture (iv) Fission. for the various reactor components ?
NUCLEAR POWER PLANT 431
28. List the advantages and disadvantages/limitations of 30. Give the application of nuclear power plants.
nuclear power plants. 31. What do you mean by ‘Economics of nuclear power plants’ ?
29. Discuss the various factors which must be considered 32. List down some safety measures for nuclear power plants.
while selecting a site for a nuclear power plant. 33. What is the future of nuclear power ?
UNSOLVED EXAMPLES
1. A nuclear reactor is developing a power of 3 MW. How 3. Mumbai requires 3000 MWh of electric energy per day. It
many atoms of U235 undergo fission per second ? How many is to be supplied by a reactor which converts nuclear energy
kg of U235 would be used in 1000 hours of operation into electric energy with an efficiency of 20 per cent. If
assuming that on an average 200 MeV is released per reactor uses nuclear fuel of U235, calculate the mass of
fission. [Ans. 9.3 × 106 ; 0.132 kg] U235 needed for one day’s operation. [Ans. 0.66 kg]
2. A city requires 100 MW of electric power on an average. If 4. The motors of an atomic ice breaker deliver 32824 kW.
this is to be supplied by a nuclear reactor of efficiency Calculate the fuel consumption of reactor per day if its
20 per cent, using U235 as the nuclear fuel, calculate the efficiency is 20 per cent. Average fission energy release of
amount of fuel required for one day’s operation. Given that U235 nuclide is 200 MeV. What would be the daily amount
energy released per fission of U235 nuclide = 200 MeV. of 7000 kcal/kg coal needed to obtain the same power if
[Ans. 0.53 kg] the efficiency now is 80%. [Ans. 0.173 kg ; 12100 tonnes]
8.1. GENERAL ASPEC TS a combined system claims the following advantages over
a single power plant/station :
The leading aim of the national economy is to make 1. Greater reliability of supply to the consumers.
available maximum amount of generating capacity with
2. When one of the stations fails to operate the
the available funds and ensure power generation at the
consumers can be fed from the other station, thus
cheapest rate possible. Since a large investment is required
avoiding complete shut down.
in power supply industry, therefore, once generating
facilities are created it is desirable to utilise them in 3. The overall cost of energy per unit of an
optimum manner. It is also of paramount importance that interconnected system is less.
most economic generating scheme should be selected to 4. There is a more effective use of transmission line
supply power at lowest cost before huge amount of money facilities at higher voltage.
is invested. When the generating facilities are established 5. Less capital investment required.
it is a wiser step to think of having integrated operation of 6. Less expenses on supervision, operation and
neighbouring power systems so that maximum energy maintenance.
generation takes place from power stations like thermal 7. The interconnection of different power plants
and nuclear and maximum energy and capacity are utilised reduces the amount of generating capacity
from the hydro-electric power stations. This is possible only required to be installed as compared to that
if we have close combined operation of different power which would be required without inter-
systems which if operated individually cannot be utilized connection.
to the maximum advantage. This leads to conclusion that 8. In an interconnected system the spinning reserve
if maximum benefit is to be yielded then power systems of required is reduced.
different states should be interconnected. It is beyond doubt
that the rapid pace of interconnection between the power 8.3. LOAD DIVISION BE T WEEN POWER
systems can greatly improve the continuity, security and
STATIONS
integrity of power supply provided it is associated with
sound mechanism for monitoring and control. Under the situation when the load curve has a very high
peak value, it is usually supplied for two or more power
8.2. ADVANTAGES OF COMBINED stations/services by interconnection. In that case, total load
as shown on load duration curve may be divided into
OPERATION OF PLANTS
following two parts :
If several power stations (such as hydro, thermal, nuclear (i) The base load (ii) The peak load.
etc.) work together to meet the demand of the consumers Base load is supplied by one power station and the
then the system is known as ‘Interconnected system’. Such other power station takes care of the peak load. In such
432
COMBINED OPERATION OF DIFFERENT POWER PLANTS 433
cases the load is economically apportioned to various occurring can be minimised which results in economical
systems in order to achieve the overall economy. operation.
In such cases it is not very necessary to interconnect (iii) Maintenance requirement is slightly higher.
the two systems of the same type. For example, if the base Diesel power stations. Due to limited generation
load is supplied by the steam power station, then it is not capacity of diesel power station it is not much suitable as a
very necessary that the peak load may also be supplied by base load plant.
the steam power station. A hydro-electric power station
can very well be adopted for supplying the peak load. Nuclear power station. (i) Initial cost is high
Similarly, a hydro-electric station can be used for supplying although operating cost is comparable with that of steam
the base load and in that case the peak load can be supplied power station.
by steam power station or a diesel engine station or any (ii) Due to limited availability of the fuel these plants
other suitable unit. However the selection of the power are not much favoured.
stations for supplying the base load or peak load is made
(iii) Whenever these plants are constructed they are
on the basis of the requirements and ability of the various
invariably used as base load as otherwise also such plants
power stations/services to meet those requirements.
suit to constant load conditions as economy in operation is
Requirements of a plant supplying the ‘Base
such plants can be achieved only, when these are used as
load’ :
base load plants.
1. Minimum operation cost.
Requirements of a plant supplying the ‘Peak
2. Continuous supply of the load.
load’ :
3. Capital cost of the plant should be minimum.
1. Low operating cost.
4. Requirement of plant maintenance should be
minimum. 2. Minimum capital cost.
5. Plant should be such that it can be easily located 3. The plant should be capable of being started from
near the load centre. cold conditions within minimum time.
6. The number of operators required should be 4. In case of emergency the plant should have the
minimum. capacity to withstand the peak load for sometime.
7. The spare parts etc. should be readily available. 5. It must have quick response to the change in load.
Taking into view the above requirements, let us now In view of the above requirements let us consider
consider various types of plants for their suitability to meet
various plants for their suitability to meet the peak load.
the base load.
Hydro-electric stations. A hydro-electric station
Hydro-electric stations. (i) In these plants the
operating cost is minimum as practically no fuel is required can be considered for this purpose :
for the purpose of power generation, and as such there is (i) It can be easily started from cold conditions as
no problem of procurement of the fuel. no warming up period is required.
(ii) Maintenance cost is lower than that of other (ii) High initial cost is the major disadvantage.
plants. (iii) However, in this case, there is no requirement
(iii) Initial cost of the plant is very high and of fuel, so whenever the output of hydro-electric station is
sometimes prohibitive.
to be utilised, it can be used as a peak station also.
(iv) These plants cannot be necessarily located near
the load centre as the same can be located at the site (iv) Particularly in case where the quantity of water
suitable for it. available for the purpose of power generation is limited,
(v) In this case there is more or less dependence on such stations are used for meeting the peak load in case of
availability of water, which in turn depends on the natural a interconnected system.
phenomenon of rain. Nuclear power stations. They do not find their
Steam power stations. (i) The capital investment use as peak load plants.
in this case as compared to hydro-electric stations is less Diesel power stations. (i) These plants can be used
but with the modern trend of using higher pressures for
for meeting peak load as they can be easily started from
the purpose, the cost of such stations has increased
cold conditions and the initial cost in this case is also not
considerably. But this increased cost has resulted in lower
operating costs so much so that even it may compete with high.
that of hydro-electric power stations. (ii) In this case the additional advantage is that the
(ii) These plants can be easily located near the load number of auxiliaries required is also limited as a result of
centre, as such the cost of transmission lines and the losses which the maintenance work required is also less.
434 POWER PLANT ENGINEERING
(iii) These plants have got good overload capacity For the plant supplying the peak load let the
(minimum being 10 per cent as per Indian Standard equation be
Specifications). (`)2 = a2 + b2 kW + c2 kWh ...(8.2)
(iv) Thermal efficiency of diesel engines being high, Since the base load plant is operated most of the
the operating cost is also less as compared to that of a steam time, therefore, normally a plant having c1 < c2 is used for
power station of equivalent capacity. meeting the base load.
Analysis of Load Sharing between Base Load Let b1 > b2.
and Peak Load Stations : Let the load between the two plants (Fig. 8.1) be
divided by arbitrary line drawn on the load duration curve
The suitability of a plant not only depends on the represented by ‘1’. Under these conditions let kWbase be
above mentioned factor but also on local conditions for a the kW for base load plant and let kWpeak be the load for
particular application. However, if the combination of two peak load plant.
plants/services is to be used, in that case the next problem In this case the total operating cost of the
is division of load between the plants. It is not desirable to combination is given as :
transfer all the loads to one plant and also depending upon C1 = a1 + a2 + b1 kWbase + b2 kWpeak
the operating characteristics of the various plants the load
+ c1 Abase + c2 Apeak ...(8.3)
between the plants should be so decided that overall
Now, if the base power is extended by the amount
economy is achieved. This load division can be easily
of d (kW) to line ‘2’, the total operating cost of the
manipulated by viewing the load duration curve of the combination will modify as follows :
plants as follows :
C2 = a1 + a2 + b1 (kWbase + d kW)
Fig. 8.1 shows a load duration curve. + b2 (kWpeak – d kW) + (Abase + d kW × h) c1
+ (Apeak – d kW × h) c2 ...(8.4)
The change in cost,
C2 – C1 = (b1 – b2) d kW + (c1 – c2) d kW × h
...(8.5)
kWpeak The optimum condition requirements are that above
Apeak change must be zero, i.e.,
b1 b2
h= ...(8.6)
d (kW) Load duration c2 c1
Power (kW)
Thermal as
peak load plant The economic balance between hydro and thermal
power in an interconnected system at any time depends
upon the nature of load curve, run-off and its seasonal
Hydro as base variation, cost of fuel, availability of condensing water etc.
load plant
There is an optimum ratio of hydro-power to total peak
Time demand which gives minimum cost for power supply. This
is particularly true for the areas where the cost of hydro-
Fig. 8.2 (a). Hydro-plant used as base load plant during power development is high and fuel cost is low. In areas
normal run-off in an interconnected system. where fuel is cheap and cost of hydro-power development
is not high, the economic power ratio lies between 0.25 to
0.4. In areas where fuel is costly and favourable hydro-
power plant sites are abundant the ratio will be higher to
the tune of 0.8–0.9.
The combined system of hydro and thermal plants
Hydro is being adopted all the world over, and is particularly
as peak useful to developing countries like India where economy is
load plant
desirable at every stage of development.
Load
(ii) The wastage of off-peak energy of thermal plants 8.8. CO-ORDINATION OF DIFFERENT
is reduced.
TYPES OF POWER PLANTS
(iii) A pumped storage plant stores the energy using
off-peak energy of thermal plant and the same is supplied In a particular region if different types of power plants are
when demand arises. available it becomes necessary to co-ordinate them and use
A combined system of a pumped storage plant and them with maximum economy. The problem of co-
nuclear power plant is proposed at Ramganga power station ordination of different types of power plants (e.g. hydro,
in Uttar Pradesh. A parallel development of nuclear power thermal, nuclear, gas turbine and diesel plants) for best
station (400 MW capacity) near the hydro-site could provide possible working and economy is very complicated as the
cheap pumping energy to pump storage plant during off
factors to be considered for economical co-ordination are
peak hours. This arrangement will enable the nuclear
large in number ; some of these factors are listed below :
station to operate at high capacity factor and thereby make
it competitive as compared to the conventional thermal (i) Initial capital cost
station in that region where the coal prices are relatively (ii) Fuel cost
high. (iii) Operation and maintenance cost
(iv) Availability of fuel
8.7. CO-ORDINATION OF HYDRO-
(v) The economics of base load and peak load
ELECTRIC AND GAS TURBINE
operation
STATIONS
(vi) The working characteristics of the plants
The working of gas turbine plants at peak load points is (vii) The transmission liability
most economical under the following conditions :
(viii) The cost of incremental power.
(i) When the amount of energy supplied at peak
The best co-ordination, several times, depends on
load is small part of the total energy.
the nature of load duration curve and availability of fuels
(ii) The load factor is less than 15%.
and resources in the country.
The following points are worth noting :
Fig. 8.3 shows an annual load curve showing loads
— The normal capacity of the gas turbine varies
allocated to different plants.
from 10 MW to 25 MW.
The local conditions may change the sequence
— The capital cost of a gas turbine plant is quite
depending upon the availability of fuels and resources.
less (` 1000 to 1200/kW) compared with steam
plant (` 1600 to 2000/kW).
Peak load plant
— The thermal efficiency of gas turbine plant (i) Gas turbine
100
(25 per cent) is less than that of a steam plant (ii) Diesel
(32 per cent). 10% L.F. (iii) Pump storage
— The high working cost of a gas turbine is 80
Hydro plants
Load duration
compensated by lower fixed charges and lower curve
with limited
Load (Percentage)
WORKED EXAMPLES
Example 8.1. The estimated total annual operating costs Refer to Fig. 8.5.
and capital charges for two proposed power stations are 5000
given by the following expressions : a
Annual cost for station A
= ` (6,00,000 + 3.0 kW + 0.015 kWh)
kWpeak = 1140
Annual cost for station B
1140000 kWh
= ` (7,50,000 + 5.0 kW + 0.014 kWh) (area aed)
e d
where kW represents the capacity of the station and kWh
represents the total annual output.
Capacity (kW)
5000 kW
kWbase = 3860
20760000 kWh
(area edcb)
b c
h = 2000 6760
8760 hours
Hours
Fig. 8.5
kWbase 5000
8760 hours
6760 8760
Fig. 8.4 5000 6760 ~
kWbase = 3860 kW
The stations are to be used for supplying a load 8760
having a load duration curve as shown in Fig. 8.4. The kWpeak = 5000 – 3860 = 1140 kW
ordinate of a point on this curve represents a certain load Cost of generation
on the station and the abscissa represents the number of Total kWh supplied by peak load plant
hours per year during which the load is equal to or exceeds 1140 2000
this amount. = = 1140000 kWh
2
Which station should be used to supply the base load, Total kWh supplied by base load plant
what should be its installed capacity and for how many
5000 8760
hours in a year should it be in operation to give the minimum = – 1140000
2
total cost per unit generated ? = 20760000 kWh
Calculate the total cost per unit generated under Cost of generation per annum for base load plant
these conditions. = ` (750000 + 5 × 3860 + 0.014 × 20760000)
Solution. Let us consider the cost equations of the two = ` (750000 + 19300 + 290640)
stations. Since the operating cost of station B is less than = ` 1059940.
that of A, so station B may be selected for supplying the
Cost of generation per annum for peak load plant
base load.
= ` (600000 + 3 × 1140 + 0.015 × 1140000)
Hours (h) for which the base load point is to be
= ` (600000 + 3420 + 17100) = ` 620520
operated can be calculated as follows :
Total cost = 1059940 + 620520 = 1680460
53 2
h= = 2000 hours. Total cost
0.015 0.014 0.001 Cost of generation per unit =
Total kWh supplied
Hence the base load point is to be operated for
2000 hours and the peak load point plant for the remaining 1680460 1680460
period. From the load duration curve, the capacity of the
=
FG
5000 8760
IJ
21900000
base load plant can be computed as follows. H 2 K
= ` 0.0767 or 7.67 p. (Ans.)
438 POWER PLANT ENGINEERING
1 1250 15
n 2
p = = 0.058 or 5.8%. (Ans.)
18.3 8760
Load (MW)
C.F. 0.058
U.F. = = 0.816 or 81.6%. (Ans.)
L.F. 0.071
Pbase
(iii) Average cost of production per kWh for the
entire system :
s
12 m For plant X (base) :
s¢ q m¢ Total units generated
1250 Hours 1
= (1250 + 8760) × (105 – 12) + 12 × 8760
2
Fig. 8.7
= 570585 MWh = 570.585 × 106 kWh
From s lms and lnp, we have CX = ` (120 × 105 × 103 + 0.028 × 570.585 × 106)
120 Pbase 1250 = ` (12.6 × 106 + 15.97 × 106) = ` 28.57 × 106
120 12 8760 For plant Y (peak) :
1250 ~
105 MW
Pbase = 120 – (120 – 12) × Total units generated = ( 21 × 1250 × 15) = 9375 MWh
8760
Ppeak = 120 – 105 = 15 MW = 9.375 × 106 kWh
(i) Installed capacity of each station : CY = ` (115 × 15 × 103 + 0.032 × 9.375 × 106)
Installed capacity of base load plant, = ` (1.725 × 106 + 0.3 × 106) = ` 2.025 × 106
Pbase = 105 MW. (Ans.) Total units generated from both the plants
Installed capacity of peak load plant = 15 × 1.22 = 570.585 × 106 + 9.375 × 106 ~ 6
580 × 10 kWh
= 18.3 MW. (Ans.)
Total generation cost,
(ii) The annual load, capacity and use factors
C = CX + CY = 28.57 × 106 + 2.025 × 106
for each station :
For base load plant : = ` 30.595 × 106
Load factor (L.F.) Average cost
THEORETICAL QUESTIONS
1. State the advantages of operating the power plants 5. State the advantages of gas turbine plant as peak load
combinedly in electric power system. plant in an interconnected system.
2. Describe the working of hydro-electric plants having ample 6. Discuss the suitability of steam power plants to supply
storage with steam power plants. the load in case of an interconnected system.
3. How would you make an economic analysis of the combined 7. List the factors which decide the distribution of plants for
operation of the hydro and steam power plants ? operation on different portions of the annual load duration
4. What are the advantages of pump storage plant as peak curve of a power system.
load plant in an interconnected system ?
UNSOLVED EXAMPLES
1. The two power stations I and II supply to a system whose If the load varies as a straight line, find for minimum cost
maximum load is 120 MW and minimum load is 12 MW of generation :
during the year. The estimated costs of these stations are (i) Installed capacity of each station.
as follows : (ii) The annual load, capacity and capacity use factor of
CI = ` (125 × kW + 0.0275 × kWh) each station.
CII = ` (120 × kW + 0.03 × kWh)
COMBINED OPERATION OF DIFFERENT POWER PLANTS 441
(iii) The average cost of production per kWh for entire C1 = 8000 + ` 75/kW + 3 paise/kWh (base load)
system. C2 = 6000 + ` 55/kW + 4 paise/kWh (peak load)
Assume reserve capacity of II as 20 per cent. Determine the following :
[Ans. (i) 80 MW, 24 MW; (ii) 65%, 65%, U.F. = 1 ; 11.5%, (i) The duration of time when peak load station will work
9.5%, U.F. = 82.5%; (iii) 5.4 paise/kWh] in order to obtain the minimum annual cost.
2. The annual load duration curve of a station varies (ii) The lowest overall cost per kW (in paise).
uniformly from 64000 kW to zero. The load is supplied by [Ans. (i) 2000 hours; (ii) 4.66 paise/kWh]
two stations whose cost equations are given as : 4. In a system the load duration curve is a straight line with
C1 = ` (84000 + 84 kW + 0.0116 kWh) a maximum demand of 45 MW tapering to zero. The load
C2 = ` (50000 + 44 kW + 0.02985 kWh) is to be taken from two sources whose annual cost
Find the minimum cost of generation in paise/kWh for equations are : C1 = ` (100 × 103 + 65.7 × kW + 0.012 ×
the system. [Ans. 3 paise/kWh (approx.)] kWh) and C2 = ` (60 × 103 + 36.5 × kW + 2.122 × kWh).
3. An annual load duration curve of a system of loads is a Find the installed capacity and service hours for each
straight line with maximum of 12 MW at the beginning station per year to give minimum cost per unit and cost
and 2 MW at the end of the year. Annual costs of base and per unit.
peak load stations are given as : [Ans. 30 MW and 15 MW, 2920 hours and 58 hours,
2.72 paise/kWh]
Economics of Power Generation 9
9.1. Introduction. 9.2. Terms and definitions. 9.3. Principles of power plant design. 9.4. Location of power plant. 9.5. Layout
of power plant building. 9.6. Cost analysis. 9.7. Selection of type of generation. 9.8. Selection of power plant equipment—
Selection of boilers—Selection of prime movers—Selection of size and number of generating units. 9.9. Economics in plant selection.
9.10. Factors affecting economics of generation and distribution of power. 9.11. How to reduce power generation cost ?
9.12. Power plant—useful life. 9.13. Economics of hydro-electric power plants. 9.14. Economics of combined hydro and
steam power plants. 9.15. Performance and operating characteristics of power plants. 9.16. Economic load sharing. 9.17.
Tariff for electrical energy—Introduction—Objectives and requirements of tariff—General tariff form—Worked Examples—Highlights—
Theoretical Questions— Unsolved Examples—Competitive Examinations Questions.
442
ECONOMICS OF POWER GENERATION 443
(ii) To cool the exhaust steam. This cooling process 9. Each wall should receive a symmetrical treatment
is done in case of diesel engines too. For bigger power in window openings etc.
stations the quantity of this cooling water is tremendous 10. The principal materials used for building the
and requires some natural source of water such as lake, power plant building are brick, stone, hollow tiles, concrete
river or even sea. Cooling towers could be used economically and steel.
as the same cooling water could be used again and again. 11. In case of a steam power plant, there are distinct
Only a part of make up water for cooling will then be parts of the building viz., boiler room, turbine room and
required. For small plants spray pounds could sometimes electrical bays. Head room required in the boiler room
be used. It is economical to limit the rise in cooling-water should be greater than in the others. Ventilation in boiler
temperature to a small value (between 6ºC and 12°C), and room presents greater difficulty because of heat liberated
to gain in cycle efficiency at the expense of increased cooling from the boiler surfaces. The turbine room is actually the
water pumping requirement. show room of the plant. Mezzanine flooring should be used
4. Type of soil available and land cost. While in the power plant. The chimney height should be sufficient
selecting a site for a power plant it is important to know so as to release the flue gases sufficiently high so that the
about the character of the soil. If the soil is loose having atmosphere is not polluted and the nearby buildings are
low bearing power the pile foundations have to be used. not affected.
Boring should be made at most of the projected site to have 12. The foundation of a power plant is one of the
an idea of the character of the various strata as well as of most important considerations. For this the bearing
the bearing power of the soil. The best location is that for capacity of the sub-soil, selection of a working factor of
which costly and special foundation is not required. safety and proportioning the wall footings to economical
In case of power plants being situated near construction should be well thought of and tested. The pile
metropolitan load centres, the land there will be very costly foundations may have to be used where the soils have low
as compared to the land at a distance from the city. bearing values.
13. In any power plant machine foundation plays
9.5. LAYOUT OF POWER PLANT an important part. The machine foundation should be able
BUILDING to distribute the weight of the machine, bed plate and its
own weight over a safe subsoil area. It must also provide
The following points should be taken care of while deciding sufficient mass to absorb machine vibrations.
about power plant building and its layout :
14. Sufficient room for storage of fuel should be
1. The power plant structure should be simple and provided indoor as well as outdoor so as to ensure against
rugged with pleasing appearance. any prolonged breakdown.
2. Costly materials and ornamental work should be
avoided. 9.6. COST ANALYSIS
3. The power plant interior should be clean, airy
and attractive. The cost of a power system depends upon whether :
4. The exterior of the building should be impressive (i) an entirely new power system has to be set up,
and attractive. or
5. Generally the building should be single storeyed. (ii) an existing system has to be replaced, or
6. The layout of the power plant should first be made (iii) an extension has to be provided to the existing
on paper, the necessary equipment well arranged and then system. The cost interalia includes :
design the covering structure. In all layout, allowances 1. Capital Cost or Fixed Cost. It includes the
must be made for sufficient clearances and for walkways. following :
Good clearance should be allowed around generators, (i) Initial cost (ii) Interest
boilers, heaters, condensers etc. Walkway clearances (iii) Depreciation cost (iv) Taxes
around hot objects and rapidly moving machinery should
(v) Insurance.
be wider than those just necessary to allow passage. Also
the galleries in the neighbourhood of high tension bus bars 2. Operational Cost. It includes the following :
should be sufficient as the space will permit. (i) Fuel cost (ii) Operating labour cost
7. Provision for future extension of the building (iii) Maintenance cost (iv) Supplies
should be made. (v) Supervision (vi) Operating taxes.
8. The height of the building should be sufficient so The above mentioned costs are discussed as follows :
that overhead cranes could operate well and the
(a) Initial cost
overhauling of the turbines etc. is no problem. Sufficient
room should be provided to lift the massive parts of the Some of the several factors on which cost of a
machines. generating station or a power plant depends are :
446 POWER PLANT ENGINEERING
(i) Location of the plant. useful life is spent. The actual life span of the plant has,
(ii) Time of construction. therefore, to be taken as shorter than what would be
(iii) Size of units. normally expected out of it.
(iv) Number of main generating units. The following methods are used to calculate the
depreciation cost :
(v) The type of structure to be used.
(i) Straight line method
The initial cost of a power station includes the
following : (ii) Percentage method
1. Land cost (iii) Sinking fund method
2. Building cost (iv) Unit method.
3. Equipment cost (i) Straight line method. It is the simplest and
commonly used method. The life of the equipment or the
4. Installation cost
enterprise is first assessed as also the residual or salvage
5. Overhead charges which will include the value of the same after the estimated life span. This salvage
transportation cost, stores and storekeeping charges, value is deducted from the initial capital cost and the
interest during construction etc. balance is divided by the life as assessed in years. Thus,
— To reduce the cost of building, it is desirable to the annual value of decrease in cost of equipment is found
eliminate the superstructure over the boiler and is set aside as depreciation annually from the income.
house and as far as possible on turbine house Thus, the rate of depreciation is uniform throughout the
also. life of the equipment. By the time the equipment has lived
— The cost on equipment can be reduced by out its useful life, an amount equivalent to its net cost is
adopting unit system where one boiler is used accumulated which can be utilised for replacement of the
for one turbogenerator. Also by simplifying the plant.
piping system and elimination of duplicate (ii) Percentage method. In this method the
system such as steam headers and boiler feed deterioration in value of equipment from year to year is
headers. The cost can be further reduced by taken into account and the amount of depreciation
eliminating duplicate or stand-by auxiliaries. calculated upon actual residual value for each year. It thus,
— When the power plant is not situated in the reduces for successive years.
proximity to the load served, the cost of a (iii) Sinking fund method. This method is based
primary distribution system will be a part of on the conception that the annual uniform deduction from
the initial investment. income for depreciation will accumulate to the capital value
(b) Interest of the plant at the end of life of the plant or equipment. In
this method, the amount set aside per year consists of
All enterprises need investment of money and this
annual instalments and the interest earned on all the
money may be obtained as loan, through bonds and shares
instalments.
or from owners of personal funds. Interest is the difference
between money borrowed and money returned. It may be Let, A = Amount set aside at the end of each
charged at a simple rate expressed as percentage per year for n years,
annum or may be compounded, in which case the interest n = Life of plant in years,
is reinvested and adds to the principal, thereby earning S = Salvage value at the end of plant life,
more interest in subsequent years. Even if the owner i = Annual rate of compound interest on
invests his own capital the charge of interest is necessary the invested capital, and
to cover the income that he would have derived from it P = Initial investment to install the plant.
through an alternative investment or fixed deposit with a
Then, amount set aside at the end of first year = A
bank. Amortization in the periodic repayment of the
principal as a uniform annual expense. Amount at the end of second year
= A + interest on A = A + Ai = A(1 + i)
(c) Depreciation
Amount at the end of third year
Depreciation accounts for the deterioration of the
= A(1 + i) + interest on A(1 + i)
equipment and decrease in its value due to corrosion,
weathering and wear and tear with use. It also covers the = A(1 + i) + A(1 + i)i
decrease in value of equipment due to obsolescence. With = A(1 + i)2
rapid improvements in design and construction of plants, Amount at the end of nth year = A(1 + i)n–1
obsolescence factor is of enormous importance. Availability Total amount accumulated in n years (say x)
of better models with lesser overall cost of generation makes = Sum of the amounts accumulated in n
it imperative to replace the old equipment earlier than its years
ECONOMICS OF POWER GENERATION 447
i.e., x = A + A(1 + i) + A(1 + i)2 + ...... + A(1 + i)n–1 (iii) Efficiency of the plant.
= A [1 + (1 + i) + (1 + i)2 + ...... + (1 + i)n–1] Labour cost. For plant operation labour cost is
...(i) another item of operating cost. Maximum labour is needed
Multiplying the above equation by (1 + i), we get in a thermal power plant using coal as a fuel. A hydraulic
x(1 + i) = A [(1 + i) + (1 + i)2 + (1 + i)3 + ...... power plant or a diesel power plant of equal capacity require
+ (1 + i)n] ...(ii) a lesser number of persons. In case of automatic power
Subtracting equation (i) from (ii), we get station the cost of labour is reduced to a great extent.
x.i = [(1 + i)n – 1] A However labour cost cannot be completely eliminated even
x=
LM (1 i) n
1 OP A with fully automatic station as they will still require some
manpower for periodic inspection etc.
MN i PQ Cost of maintenance and repairs. In order to
where x = (P – S) avoid plant breakdowns maintenance is necessary.
LM (1 i) n
1 OP A Maintenance includes periodic cleaning, greasing,
P–S=
MN i PQ ...(9.6) adjustments and overhauling of equipment. The material
used for maintenance is also charged under this head.
or A= M
L i OP (P – S) ...(9.7)
Sometimes an arbitrary percentage is assumed as
maintenance cost. A good plan of maintenance would keep
N (1 i) n
1Q the sets in dependable condition and avoid the necessity of
(iv) Unit method. In this method some factor is too many stand-by plants.
taken as a standard one and depreciation is measured by Repairs are necessitated when the plant breaks
that standard. In place of years an equipment will last, down or stops due to faults developing in the mechanism.
the number of hours that an equipment will last is The repairs may be minor, major or periodic overhauls and
calculated. This total number of hours is then divided by
are charged to the depreciation fund of the equipment. This
the capital value of the equipment. This constant is then
item of cost is higher for thermal plants than for hydro-
multiplied by the number of actual working hours each
year to get the value of depreciation for that year. In place plants due to complex nature of principal equipment and
of number of hours, the number of units of production is auxiliaries in the former.
taken as the measuring standard. Cost of stores (other than fuel). The items of
consumable stores other than fuel include such articles as
(d) Operational cost lubricating oil and greases, cotton waste, small tools,
The elements that make up the operating chemicals, paints and such other things. The incidence of
expenditure of a power plant include the following costs : this cost is also higher in thermal stations than in hydro-
(i) Cost of fuels. electric power stations.
(ii) Labour cost. Supervision. In this head the salary of supervising
(iii) Cost of maintenance and repairs. staff is included. A good supervision is reflected in lesser
breakdowns and extended plant life. The supervising staff
(iv) Cost of stores (other than fuel).
includes the station superintendent, chief engineer,
(v) Supervision. chemist, engineers, supervisors, stores incharges, purchase
(vi) Taxes. officer and other establishment. Again, thermal stations,
Cost of fuels. In a thermal station fuel is the particularly coal fed, have a greater incidence of this cost
heaviest item of operating cost. The selection of the fuel than the hydro-electric power stations.
and the maximum economy in its use are, therefore, very Taxes. The taxes under operating head includes the
important considerations in thermal plant design. It is following :
desirable to achieve the highest thermal efficiency for the (i) Income tax
plant so that fuel charges are reduced. The cost of fuel (ii) Sales tax
includes not only its price at the site of purchase but its (iii) Social security and employee’s security etc.
transportation and handling costs also. In the hydroplants
the absence of fuel factor in cost is responsible for lowering
9.7. SELECTION OF TYPE OF
the operating cost. Plant heat rate can be improved by the
use of better quality of fuel or by employing better GENERATION
thermodynamic conditions in the plant design. While choosing the type of generation the following points
The cost of fuel varies with the following : should be taken into consideration :
(i) Unit price of the fuel. 1. The type of fuel available or availability of suitable
(ii) Amount of energy produced. sites for water power generation.
448 POWER PLANT ENGINEERING
production is usually chosen. In case of all types of Gas turbine power plant. The cost of the gas
equipment the working efficiency is generally higher with turbine power plant increases as the simple plant is
larger sizes of plants and with high load factor operation. modified by inclusion of other equipment such as
Also, the capital cost per unit installation reduces as the intercooler, regenerator, reheater, etc. but the gain in
plant is increased in size. However, a bigger size of plant thermal efficiency and thereby a reduction in operating
would require greater investment, and possibilities of lower cost may justify this additional expense in first cost.
than optimum load factor usually increase with larger size Hydro-electric power plant. As compared with
of the plant. thermal stations an hydro-electric power plant has little
Steam power plants. In case of steam power plants operating cost and if sufficient water is available to cater
the choice of steam conditions such as throttle pressure to peak loads and special conditions for application of these
and temperature, is an important factor affecting operating plants justify, power can be produced at a small cost.
costs and is, therefore, very carefully made. As throttle The capital cost per unit installed is higher if the
pressure and temperature are raised the capital cost quantity of water is small. Also, the unit cost of conveying
increases but the cycle efficiency is increased. The advantage water to the power house is greater if the quantity of water
of higher pressures and temperatures is generally not is small. The cost of storage per unit is also lower if the
apparent below capacity of 10,000 kW unless fuel cost is quantity of water stored is large.
very high. An existing plant capacity may be increased by
Heat rates may be improved further through storing additional water through increasing the height of
reheating and regeneration, but again the capital cost of dam or by diverting water from other streams into the head
additional equipment has to be balanced against gain in reservoir. However, again it would be an economic study
operating cost. whether this additional cost of civil works would guarantee
The use of heat reclaiming devices, such as air sufficient returns.
preheaters and economisers, has to be considered from the Some hydro-power plants may be made automatic
point of economy in the consumption of fuel. or remote controlled to reduce the operating cost further,
Internal combustion engine plants. In this case but the cost of automation has to be balanced against the
also the selection of I.C. engines also depends on saving effected in the unit cost of generation.
thermodynamic considerations. The efficiency of the engine Interconnected hydro-steam system. In such a
improves with compression ratio but high pressures system where peak loads are taken up by steam units, the
necessitate heavier construction of equipment which capacity of water turbine may be kept somewhat higher
increases cost. than the water flow capacity at peak loads, and lesser than
The choice may also have to be made between four- or equal to maximum flow of river. This would make it
stroke and two-stroke engines, the former having higher possible for the water turbine to generate adequate energy
thermal efficiency and the latter lower weight and cost. at low cost during sufficient water flow.
The cost of the supercharger may be justified if there Some of the principal characteristics of hydro-
is a substantial gain in engine power which may balance electric, steam and diesel power plants are listed below :
the additional supercharge cost.
S.No. Characteristics Hydro-plant Steam plant Diesel plant
1 1 1
3. Running and maintenance cost (as
10 7 6
a fraction of total generation cost)
Efficiency
efficiency of a power plant is the ratio of useful energy output
to the total energy input during the period considered. This
measure of performance varies with uncontrolled conditions
viz. (i) cooling water temperature, (ii) quality of fuel, and
(iii) shape of load curve. Thus, unless all plant performances
are corrected to the same controlled conditions it is not a
satisfactory standard of comparison.
Output (or load)
The performance of a plant can be precisely
(b) Efficiency curve.
represented by the input-output curve from the tests
conducted on individual power plant. The input-output
curve is graphical representation between the net energy
output (L) and input (I). The input is generally expressed in
He
cusecs or m3/s of water.
at
te
ra
In general input-output may be represented as
follows :
I = a + bL + cL2 + dL3 e
l rat
where I = Input, en
ta
L = Output, and cr em
In
a, b, c and d = Constants
Input-output curve. Fig. 9.5 (a) shows an input- Output (or load)
output curve. In order to keep the apparatus functioning (c) Heat rate and incremental
rate curves.
at zero load, a certain input (I0) is required to meet frictional
and heat losses. Fig. 9.5
Efficiency curve. The efficiency of the power plant
I
is defined as the ratio of output to input.
L L
Efficiency, =
I a bL cL2 dL3
By using the above formula the efficiency for any
given load can be calculated.
An efficiency curve is shown in Fig. 9.5 (b).
Input
5
+L
Input (I)
dI
=0 ...(i)
dI1
where, I= I1 + I2 = input of generator 1 + input of
generator 2
= combined input to generators 1 and 2
L= L1 + L2 = output of generator 1 + output of L1 L2
generator 2
Output (L)
= combined output of generators 1 and 2
F∵ dI I Fig. 9.7
Then
dI dI dI
1 2 =0
dI1 dL1 dL1
GH dI1
0 JK L
Efficiency =
As I is constant. I
dI1 dI I
2 ...(ii) Heat rate (HR) =
dL1 dL1 L
dI2 dI dL2 For minimum value of heat rate
2
But
dL1 dL2 dL1
...(iii)
d FG IJ
d I
Also, L2 = L – L1 dL
(HR) = 0 or
H K
dL L
dL2 dL dL1 LdI IdL
= 0 or LdI = IdL
dL1 dL1 dL1 L2
Since L is constant. I dI
dL or
=0 L dL
dL1 This shows that efficiency will be maximum at a load
dL2 dL1 where heat rate is equal to incremental heat rate.
Hence, =–1 ..(iv)
dL1 dL1
Substituting in (iii), we get 9.17. TARIFF FOR ELEC TRICAL ENERGY
dI2 dI
2 ...(v) 9.17.1. Introduction
dL1 dL2
From (ii) and (v), The cost of generation of electrical energy consists of fixed
cost and running cost. Since the electricity generated is to
dI1 dI be supplied to the consumers, the total cost of generation
2 ...(vi)
dL1 dL2 has to be recovered from the consumers. Tariffs or energy
Thus, for minimum combined input to carry a given rates are the different methods of charging the consumers
combined output, the slopes of the input-output curve for for the consumption of electricity. It is desirable to charge
each unit must be equal. the consumer according to the maximum demand (kW) and
If there are n units, supplying a constant load, then the energy consumed (kWh). The tariff chosen should
the required condition for the minimum input or maximum recover the fixed cost, operating cost and profit etc. incurred
system efficiency is in generating the electrical energy.
dI1 dI dI dI 9.17.2. Objectives and Requirements of Tariff
2 3 ...... n ...(vii)
dL1 dL2 dL3 dLn Objectives of tariff :
Condition for maximum efficiency :
1. Recovery of cost of capital investment in
Refer to Fig. 9.7. The load at which efficiency will generating equipment, transmission and
be maximum, the heat rate will be minimum at that load distribution system.
as efficiency is inverse of heat.
456 POWER PLANT ENGINEERING
2. Recovery of the cost of operation, supplies and 5. Doherty rate (Three-part tariff).
maintenance of the equipment. 6. Wright demand rate.
3. Recovery of the cost of material, equipment, 1. Flat demand rate :
billing and collection cost as well as for The flat demand rate is expressed as follows :
miscellaneous services.
z = ax ...(9.8)
4. A net return on the total capital investment must
i.e., the bill depends only on the maximum demand
be ensured.
irrespective of the amount of energy consumed. It is based
Requirements of tariff : on the customer’s installation of energy consuming devices
1. It should be easier to understand. which is generally denoted by so many kW per month or
2. It should provide low rates for high consumption. per year. It is probably one of the early systems of charging
3. It should be uniform over large population. energy rates. It was based upon the total number of lamps
4. It should encourage the consumers having high installed and a fixed number of hours of use per year. Hence
load factors. the rate could be expressed as a price per lamp or unit of
installed capacity.
5. It should take into account maximum demand
charges and energy charges. Now-a-days the use of this tariff is restricted to signal
system, street lighting etc., where the number of hours are
6. It should provide incentive for using power
fixed and energy consumption can be easily predicted. Its
during off-peak hours.
use is very common to supplies to irrigation tubewells, since
7. It should provide less charges for power the number of hours for which the tubewell feeders are
connection than lighting. switched on are fixed. The charge is made according to horse
8. It should have a provision of penalty for low power of the motor installed.
power factors.
9. It should have a provision for higher demand
charges for high loads demanded at system x=4
peaks.
10. It should apportion equitably the cost of service
to the different categories of consumers. x=3
used. This tariff is sometimes used for residential and The variation of bill according to this method is
commercial consumer. The variation of bill according to shown in Fig. 9.10.
the variation of energy consumed is shown in Fig. 9.9. The block meter rate accomplishes the same purpose
of decreasing unit energy charges with increasing
consumption as the step meter rate without its defect. Its
main defect is that it lacks a measure of the customer’s
demand.
This tariff is very commonly used for residential and
commercial customers. In many states of India, a reverse
form of this tariff is being used to restrict the energy
consumption. In this reverse form the unit energy charge
z increases with increase in energy consumption.
4. Hopkinson demand rate (Two-part tariff) :
This method charges the consumer according to his
maximum demand and energy consumption. This can be
expressed as
z = a + by ...(9.10)
This method requires two meters to record the
y maximum demand and energy consumption of the
consumer. The variation of z with respect to y taking x as
Fig. 9.9. Straight meter rate. parameter is shown in Fig. 9.11.
Advantage. Simplicity.
Disadvantages 1. The consumer using no energy
will not pay any amount although he has incurred some
expenses to the power station.
x=3
2. This method does not encourage the use of x=2
electricity unless the tariff is very low. x=1
3. Block meter rate :
In order to remove the inconsistency of straight
meter rate, the block meter rate charges the consumers on z
a sliding scale. The term ‘block’ indicates that a certain
specified price per unit is charged for all or any part of
such units. The reduced prices per unit are charged for all
or any part of succeeding block of units, each such reduced
price per unit applying only to a particular block or portion
thereof.
y
WORKED EXAMPLES
Example 9.1. The maximum demand of a power station is 96000 kW and daily load curve is described as follows :
(i) Determine the load factor of power station. (ii) Load factor of standby equipment :
(ii) What is the load factor of standby equipment The standby equipment supplies
rated at 30 MW that takes up all load in excess of 72 MW ? 84 – 72 = 12 MW for 4 hours (14 – 18)
Also calculate its use factor.
96 – 72 = 24 MW for 4 hours (18 – 22)
Solution. Load curve is shown in Fig. 9.13.
Energy generated by standby equipment
Energy generated = area under the load curve
= 48 × 6 + 60 × 2 + 72 × 4 + 60 × = (12 × 4 + 24 × 4) × 103
2 + 84 × 4 + 96 × 4 + 48 × 2 = 144 × 103 kWh
= 1632 MWh = 1632 × 103 kWh. Time for which standby equipment remains in
(i) Load factor : operation (from the load curve)
1632 103 = 4 + 4 = 8 hours
Average load = = 68000 kW
24 144 103
Maximum demand = 96000 kW (given) Average = = 18 × 103 kW
8
Average load 68000 18 103
Load factor = Load factor = = 0.75. (Ans.)
Maximum demand 96000
24 103
= 0.71. (Ans.)
ECONOMICS OF POWER GENERATION 459
100 96
90 84 Load
80
72 curve
70
Load (MW)
60 60 60
50 48 48
40
30
20
10
0 2 4 6 8 10 12 14 16 18 20 22 24
Time (hours)
Fig. 9.13
E
Use factor =
C t
where, E = Energy generated,
C = Capacity of the standby equipment, and
t = Actual number of hours the plant has been
in operation.
144 103
Use factor =
30 103 8
= 0.6. (Ans.)
+Example 9.2. An electrical system experiences linear
changes in load such that its daily load curve is defined as
follows :
12 PM 24
2 AM 12
6 AM 12
8 AM 60 Fig. 9.14
12 AM 60
12.30 PM 48 Chronological load and load duration curves are
1 PM 60 drawn as shown in Fig. 9.14 (a), (b). The procedure for
5 PM 60 constructing the load duration curve from chronological
6 PM 84 load curve is as follows :
12 PM 24 — The abscissa of the load duration curve is laid
off equal to the number of hours in the
(i) Plot the chronological and load duration curve
chronological curve, in this case 24 hours.
for the system.
— The criterion of plotting the load duration curve
(ii) Find the load factor.
makes the abscissa at any load ordinate equal
(iii) What is the utilisation factor of the plant serving to the length of the abscissa intercepted by that
this load if its capacity is 120 MW. load ordinate on the chronological curve. Thus :
Solution. (i) Chronological load and load duration
curves :
460 POWER PLANT ENGINEERING
(i) At the maximum demand or peak load, the (i) Draw the load curve.
intercept is one point which will be plotted at 0 hour. (ii) Draw load duration curve.
(ii) At 70 MW load the intercept is x1 hours and is (iii) Choose suitable generating units to supply the
plotted as x1 hour on the load duration curve. load.
(iii) At 55 MW load the intercept is a total of (x2 + x3) (iv) Calculate the load factor.
and is plotted accordingly. (v) Calculate the plant capacity factor.
(iv) At minimum load of 12 MW the intercept covers Solution. (i) Load curve :
the entire period of 24 hours.
The load curve is shown in Fig. 9.15 (a).
Following points may be noted :
(ii) Load duration curve :
1. Any point on the load duration curve is a measure
The load duration curve is shown in Fig. 9.15 (b).
of number of hours in a given period during
which the given load and higher loads have (iii) Selection of generating units :
prevailed. Load duration curve will indicate the operation
2. If the chronological curve indicated a constant schedule of different generating units.
demand during the entire day, it would be of 1. One generating unit (unit 1) of 45 MW
rectangular shape and load duration curve would will run for 24 hours
be an exact duplicate. 2. Second generating unit (unit 2) of 45 MW
(ii) Load factor : will run for 18 hours
From the load duration curve, the average load can 3. Third generating unit (unit 3) of 45 MW
be estimated. will run for 10 hours
Average load for the period 4. Fourth generating unit (unit 4) of 15 MW
Total energy in load curve for period will run for 4 hours
=
Total number of hours in period One additional unit (unit 5) should be kept as
FG 24 + 12 IJ 2 12 4 FG 12 60 IJ standby. Its capacity should be equal to the capacity of
H 2 K H 2 K biggest set, i.e., 45 MW.
2 60 4 G
F 60 48 IJ 1 Energy generated
H 2 K 2 = 45 × 6 + 135 × 6 + 90 × 2 + 150 × 4 + 75 × 6
G
F 48 60 IJ 1 60 4 FG 60 84 IJ = 270 + 810 + 180 + 600 + 450 = 2310 MWh
H 2 K 2 H 2 K Average load
2310 103
1 G
F 84 24 IJ 6 = kW = 96250 kW
=
H 2 K 24
Maximum demand
24
= 150 × 103 = 150000 kW
36 48 72 240 27 27 240 72 324
=
24
1086
= = 45.2 MW
24
Load factor
45.2
= = 0.45 or 54%. (Ans.)
84
(iii) Utilisation factor :
Utilisation factor
Maximum load
=
Rated capacity of the plant
84
= = 0.70 or 70%. (Ans.)
120
+Example 9.3. A power station has to supply load as
follows :
(a) Load curve
Time (hours) : 0–6 6–12 12–14 14–18 18–24
Load (MW) : 45 135 90 150 75
ECONOMICS OF POWER GENERATION 461
96250
= = 0.64. (Ans.)
150000
(v) Plant capacity factor :
Plant capacity factor
E
=
Ct
where, E = Energy generated (kWh),
C = Capacity of the plant (kW),
= 45 × 4 + 1 × 15 = 195 MW = 195 × 103 kW, and
t = Number of hours in the given period
= 24 hours.
Plant capacity factor
(b) Load duration curve
2310 103
Fig. 9.15 = = 0.49. (Ans.)
195 103 24
(iv) Load factor :
Example 9.4. A generating station has a maximum demand
Average load
Load factor = of 5000 kW, and the daily load on the station is as follows :
Maximum demand
Time (hours) 1 PM to 5 PM 5 PM to 7 PM 7 PM to 9 PM 9 PM to 11 PM
Maximum demand
Demand factor =
Connected load
50 50
= = 0.89
20 + 17 + 10 + 9 56
Hence, demand factor = 0.89. (Ans.)
Example 9.6. The yearly duration curve of a certain plant
can be considered as a straight line from 300 MW to
80 MW. Power is supplied with one generating unit of
200 MW capacity and two units of 100 MW capacity each.
Determine :
(i) Installed capacity (ii) Load factor
(iii) Plant factor (iv) Maximum demand
(b) Load duration curve
(v) Utilization factor.
Fig. 9.16 Solution. The load duration curve is shown in Fig. 9.17.
(vi) Plant capacity factor :
Plant capacity factor 300
E 66000
= Load duration
C t (2500 1500 1000 2500) 24 curve
= 0.367. (Ans.)
200
Example 9.5. A 60 MW power station has an annual peak
Load (MW)
79.3
(0.07 P1 + 24) dP1
Average load
1000
= = 41.67 MW L 0.07 P
=M 1
2
24 P1
OP 90
24
Heat supplied during 24 hours in this case MN 2 PQ 79.3
z
= 4 × 106 × 1102.5 × 24 kJ/day
90
= 105840 × 106 kJ/day = (0.075 P2 + 22) dP2
Net saving per day 100.7
S. No. Items Fixed cost per year Running cost per year
(in `) (in `)
10
1. Interest, depreciation etc. of the plant × 10000 × 800
100
= ` 800 × 103 –
5
2. Interest, depreciation etc. of the × 350 × 103
100
transmission and distribution = 17.5 × 103 –
3. Annual cost of coal – 250000 × 6
= 1500 × 103
4. Operating cost – = 350 × 103
5. Plant maintenance cost = 30 × 103 = 40 × 103
F 1 I O 12
Example 9.39. A motor of 25 H.P. connected to a condensate
G 25 0.7355 (365 24) JP
1 70
pump has been burnt beyond economical repairs. Two
alternatives have been proposed to replace it by : H 2 100 0.8 K Q 100
12
Cost at full load at half load = (56188.8 + 70470) × = ` 15199
100
Motor A : ` 5000 90% 85% Total cost of motor B
= 154 + 175 + 200 + 15199 = ` 15728/year.
Motor B : ` 3500 86% 80%
Hence motor A is economical since its annual cost is
The life of each motor is 20 years and its salvage less than motor B.
value is 12 per cent of the initial cost. The rate of interest is +Example 9.40. The following proposals are under
5 per cent annually. The motor operates at full load for 30% consideration for an industry which has a maximum
of time and at half load for the remaining period. The demand of 45 MW and a load factor of 0.45 :
annual maintenance cost of motor A is ` 400 and that of
(i) A steam plant having an initial cost of ` 1200/kW
motor B is ` 200. The energy rate is 12 paise/kWh.
and maintenance cost of 2.4 paise/kWh. The coal of C.V. of
Which motor will be economical ? 2550 kJ/N is used. The overall efficiency of the plant is
Solution. Motor A : 24 per cent.
12 (ii) An hydro-plant having a capital cost of
Salvage value = × 5000 = ` 600
100 ` 3600/kW and a running cost of 0.6 paise/kWh.
5000 600 Assuming interest and depreciation rate of 10 per
Depreciation = = ` 220/year
20 cent for steam plant and 8 per cent for hydro-plant,
5 determine the price of coal above which steam station is
Interest = × 5000 = ` 250/year uneconomical.
100
Maintenance = ` 400 Solution. Energy required per year
Energy given to motor = Peak load × load factor × (365 × 24)
Load on motor time in hours = 45 × 103 × 0.45 × (365 × 24)
=
Efficiency of the motor = 177.39 × 106 kWh/year
ECONOMICS OF POWER GENERATION 481
(i) Steam plant : High voltage : ` 50/kW per year + paise 4/kWh
Interest and depreciation Low voltage : ` 55/kW per year + paise 5/kWh
10 In order to have high voltage supply, consumer has
= × (45 × 103) × 1200 = ` 5.4 × 106
100 to install his own transformer which costs ` 110/kW. The
Maintenance cost losses in the transformer are 4 per cent of full load.
Determine the number of working hours per week above
2.4
= × 177.39 × 106 = ` 4.257 × 106 which the high voltage supply will be economical.
100
Assume : interest and depreciation 12 per cent of
Let Wcoal = Weight of coal in kN used/year, and
capital, working weeks per year 50 and load of consumer
x = Cost of coal in rupees per kN as 1.5 MW.
Wcoal × 103 × C.V. × overall Solution. Consumer load
= 177.39 × 106 × 3.6 × 103 = 1.5 MW = 1500 kW
(∵ 1 kWh = 3.6 × 103 kJ) Required rating of transformer
6
177.39 10 (3.6 10 ) 3 1500
or Wcoal = = = 1562 kW
103 2550 0.24 (1 0.4)
= 1.043 × 106 kN/year Cost of the transformer to the consumer
Now, total cost of steam plant = 1562 × 110 = ` 171820
= Interest + maintenance cost + fuel cost Annual interest and depreciation
= 5.4 × 106 + 4.257 × 106 + 1.043 × 106 × x 12
= × 171820 = ` 20618
...(1) 100
Let the number of hours for which power is required
(ii) Hydel plant :
by the consumer = x hours/week
Interest and depreciation
Number of hours for which power is used during
8 the year = 50x hours
= 45 × 103 × 3600 × = ` 12.96 × 106
100 (i) Number of units consumed from low voltage side
Running cost if the load is connected to low voltage
0.6 = 1500 × 50x = 75000x kWh/year
= × 177.39 × 106 = ` 1.064 × 106
100 (ii) Number of units consumed from high voltage
Total cost of hydel plant side if the load is connected to high voltage
= 12.96 × 106 + 1.064 × 106 = 1562 × 50x = 78100x kWh/year
= ` 14.024 × 106 ...(2) Total cost from low voltage supply in rupees
The steam and hydel station will be equally 5
economical if the total cost/year remains same. = 1500 × 55 + 75000x ×
100
Equating the values of (1) and (2), we get = 82500 + 3750x ...(1)
5.4 × 106 + 4.257 × 106 + 1.043 × 106 × x Total cost from high voltage supply in rupees
= 14.024 × 106 4
= 1562 × 50 + 78100x × + 20618
100
or 5.4 + 4.257 + 1.043 x
= 98718 + 3124x ...(2)
= 14.024 (Dividing both sides by 106)
It both the systems cost the same to the consumer,
14.024 5.4 4.257 then equating (1) and (2), we get
x= = ` 4.19 per kN
1.043 82500 + 3750x = 98718 + 3124x
Hence price coal above which steam station is 98718 82500 16218
uneconomical = ` 4.19 per kN. (Ans.) i.e., x= = 25.9 hours.
(3750 3124) 626
Example 9.41. An industrial consumer has a choice Hence the number of working hours above which the
between low and high voltage supply available at the high voltage supply will be economical
following rates :
= 25.9 hours. (Ans.)
482 POWER PLANT ENGINEERING
Example 9.42. A diesel electric station has 4-generating Cost of lubricating oil
sets, each of 500 kW and 1 of 400 kW capacity. = (6.57 × 106 × 0.0024) × 45
The other data is given below : = ` 0.71 × 106
Maximum demand 1500 kW
Total variable cost per year
Load factor 0.5
Capital cost ` 10000/kW = (23.65 + 0.71) × 106 = ` 24.36 × 106
Annual cost (interest + depreciation Total cost = Fixed cost + variable cost
+ insurances and taxes) 16% of capital cost = 3.085 × 106 + 24.36 × 106
Annual maintenance cost ` 45000 = ` 27.44 × 106
Operation cost ` 8000 Cost per kWh generated
Fuel used 0.45 kg/kWh
Total cost
Cost of fuel ` 8/kg =
Energy generated per year
Lubricating oil used 0.0024 kg/kWh
Cost of lubricating oil ` 45/kg 27.44 106
= ` 4.18. (Ans.)
~
Calorific value of fuel used 41000 kJ/kg 6.57 106
Generator efficiency 90% (iv) Overall efficiency of the plant, overall :
Determine the following :
Output 6.57 106 3600 (kJ)
(i) The rating of diesel engine, overall =
(ii) Energy produced per year, Input 6.57 106 0.45 41000 (kJ)
(iii) Cost of generation, `/kWh, and = 0.195 or 19.5%. (Ans.)
(iv) Overall efficiency of the plant. (N.U.) Example 9.43. A load curve of a factory follows a parabola
and it works for 8 hours a day from 10 A.M. to 6 P.M. The
Solution. (i) The rating of diesel engine :
Rating of first 3-sets maximum and minimum loads of the factory are 3 MW
and 1 MW. The capacity of the diesel power plant supplying
500
= = 555 kW. (Ans.) the power to the factory is 2 MW. Determine the following :
0.9
Rating of last set (i) Load factor and capacity factor of the plant
supplying power to the factory.
400
= = 445 kW. (Ans.) (ii) Energy consumption of the factory per month
0.9 assuming it works for 26 days per month and 8 hours per
(ii) Energy produced per year : day.
Average demand
(iii) Electrical charges to be paid by the factory if the
= Maximum demand × load factor charges are ` 60/kW for maximum load during a day and
= 1500 × 0.5 = 750 kW ` 2.75/kWh.
Energy produced per year
The time at 6 A.M. may be taken as zero. (M.U.)
= 750 × 8760 = 6.57 × 106 kWh. (Ans.)
Solution. Given : Working hours per day = 8 (10 A.M. to
(iii) Cost of generation, `/kWh :
Fixed cost per year : 6 P.M.) ; Maximum load = 3 MW ; Minimum load =
Capital cost = (3 × 500 + 1 × 400) × 10000 1 MW ; Capacity of diesel power plant = 2 MW ; Tariff :
= ` 1.9 × 107 ` 60/kW (maximum load) ; ` 2.75/kWh.
16 The load curve is shown in Fig. 9.18.
Annual fixed cost = × 1.9 × 107 = ` 0.304 × 107 The load curve is given by :
100
Maintenance cost= ` 45000 = ` 0.0045 × 107 y2 = ax,
Total fixed cost = ` (0.304 + 0.0045) × 107 where x and y represent hours and MW respectively.
= ` 0.3085 × 107 The boundary conditions are :
Variable cost per year : At x = 0, y = 0 ; At x = 4, y = 1
Fuel cost = (6.57 × 106 × 0.45) × 8 1
= ` 23.65 × 106 1 = a × 4 or a =
4
ECONOMICS OF POWER GENERATION 483
y (MW) Example 9.44. The daily load curve for a power plant is
given by the following equation :
L = 350 + 10t – t2
2
y = ax where t is time in hours from 0 to 24 hours and L is in MW
3 calculate :
(i) Value of maximum load and when it occurs, and
1
(ii) Load factor of the plant.
x
0 6 A.M. 10 A.M. 6 P.M. (hours) Draw load curve and load duration curve. (P.U.)
Solution. Equation of the load curve,
L = 350 + 10t – t2 ...(Given)
4 hours 8 hours
(i) Value of maximum load and when it
Fig. 9.18 occurs :
The condition for finding the value of maximum load
x x dL
y2 = (load curve)
or y = is =0
4 2 dt
The above load curve also fulfills the another
d
condition which is : (350 + 10t – t2) = 0 or 10 – 2t = 0
dt
At x = 12, y = 3 t = 5 hours.
e j
3
12
2
4
3=3 Thus, the maximum load occurs at 5th hour during
the day. (Ans.)
The average load of the factory on the diesel power Lmax = 350 + 10 × 5 – 52 = 375 MW. (Ans.)
plant is given by :
z z
(ii) Load factor of the plant :
1 12 1 12 x
Lav = y . dx dx The average load on the plant is given by
z z
8 4 8 4 2
LM OP 1 24 1 24
12
1 2 1 Lav = L . dt (350 10t t 2 ) dt
( x)1.5 [(12)1.5 – (4)1.5]
16 3 N Q 4
24
24 0 24 0
= 1.4 MW
1 LM
350t 10
t2 t3
OP 24
t (h) L (MW) t (h) L (MW) From the above data the load curve and load
duration curve are drawn as shown in Fig. 9.19 (a) and
1 359 13 311 (b) respectively.
2 366 14 294
3 371 15 275 375
375
4 374 16 254
5 375 17 231
6 374 18 206
L
7 371 19 179 14 14
8 366 20 150
0 456 12 18 24 0 6 12 18 24
9 359 21 119 t t
10 350 22 86 (a) Load curve. (b) Load duration curve.
11 339 23 51 Fig. 9.19
12 326 24 14
HIGHLIGHTS
THEORETICAL QUESTIONS
UNSOLVED EXAMPLES
1. The maximum demand of a power station is 80000 kW 4. A generating station has a maximum demand of 20 MW,
and the load curve is defined as follows : a load factor of 0.6, a plant capacity of 0.48 and a plant
Time (hours) : 0–6 6–8 8–12 12–14 14–18 18–22 22–24 use factor of 0.80. Find :
(i) The daily energy produced.
Load (MW) : 40 50 60 50 70 80 40
(ii) The reserve capacity of the plant.
(i) Determine the load factor of power station. (iii) The maximum energy that could be produced if the
(ii) What is the load factor of standby equipment plant were running all the time.
rated at 25 MW that takes up all load in excess of (iv) The maximum energy that could be produced daily, if
60 MW ? Also calculate its use factor. the plant when running, according to operating
[Ans. (i) 0.71, (ii) 0.75, 0.6] schedule, were fully loaded.
2. The following load is to be supplied by a power station : [Ans. (i) 2.88 × 105 kWh, (ii) 5000 kW,
Load (MW) : 30 90 60 100 50 (iii) 2.88 × 105 kWh, (iv) 3.60 × 105 kWh]
Time (hours) : 0–6 6–12 12–14 14–18 18–24 5. A proposed power station has to supply load as follows :
(i) Draw the load curve. Time (hours) : 01–08 08–12 12–17 17–20 20–23 23–01
(ii) Draw the load duration curve. Load (MW) : 10 20 25 18 35 20
(iii) Choose suitable generating units to supply the load. After drawing the load curve, find out the load factor. Also
(iv) Calculate the load factor. choose suitable generating units to supply this load,
(v) Calculate plant capacity factor. maintaining reliability of supply. Prepare operation
[Ans. (iii) 30 MW (4 units including standby unit), schedule for the machine and calculate plant use factor.
10 MW (one unit), (iv) 0.64, (v) 0.49] [Ans. 0.56, 0.92]
3. The yearly duration curve of a certain plant can be con- 6. A generating station supplies the following loads :
sidered as a straight line from 150 MW to 40 MW. Power 15 MW ; 12 MW ; 8 MW and 0.5 MW. The station has a
is supplied with one generating unit of 100 MW capacity maximum demand of 20 MW and the annual load factor
and two units of 50 MW capacity each. Determine : is 0.5. Find :
(i) Installed capacity (ii) Load factor (i) Number of units supplied annually.
(iii) Plant factor (iv) Maximum demand (ii) Diversity factor.
(v) Utilization factor. [Ans. (i) 876 × 105 kWh, (ii) 1.775]
[Ans. (i) 200 MW, (ii) 0.633, (iii) 0.475, 7. A base load power station and standby power station share
(iv) 150 MW, (v) 0.75] a common load as follows :
486 POWER PLANT ENGINEERING
Base load station annual output = 150 × 106 kWh ; Base 13. A power station has a maximum demand of 15 MW, a
load station capacity = 35 MW ; Maximum demand on load factor of 0.7, a plant capacity factor of 0.525 and a
base load station = 30 MW ; Standby station capacity = plant use factor of 0.85. Find :
18 MW ; Standby station annual output = 140 × 106 kWh ; (i) The daily energy produced.
Maximum demand (peak load) on standby station = (ii) The reserve capacity of the plant.
15 MW. Determine the following for both power stations : (iii) The maximum energy that could be produced daily if
(i) Load factor the plant operating schedule is fully loaded when in
(ii) Capacity factor (plant factor). operation.
LMAns. Base load station : (i) 0.57 (ii) 0.49 OP [Ans. (i) 252000 kWh, (ii) 5000 kW, (iii) 296470 kWh]
N Standby power station : (i) 0.107 (ii) 0.09 Q 14. Determine the annual cost of a feed water softner from
the following data :
8. A power system has the following load particulars : Cost = ` 80000 ; Salvage value = 5% ; Life = 10 years ;
Maximum Load Diversity Annual repair and maintenance cost = ` 2500 ; Annual
demand factor between cost of chemicals = ` 5000 ; Labour cost per month =
consumers ` 300 ; Interest on sinking fund = 5%. [Ans. ` 17,140]
1. Residential load : 1000 kW 0.2 1.3 15. Estimate the generating cost per kWh delivered from a
2. Commercial load : 2000 kW 0.3 1.1 generating station from the following data :
Plant capacity = 50 MW
3. Industrial load : 5000 kW 0.8 1.2
Annual load factor = 0.4
Overall diversity factor may be taken as 1.4.
Capital cost = ` 1.2 crores
Determine the following :
Annual cost of wages, taxation etc.
(i) Maximum demand on system.
(ii) Daily energy consumption (total). = ` 4 lacs
(iii) Overall load factor. Cost of fuel, lubrication, maintenance etc.
(iv) Connected load (total) assuming that demand factor = 1.0 paise per kWh generated.
for each load is unity. Interest 5% per annum, depreciation 5% per annum of
9. The following data is available for a steam power station : initial value. [Ans. 1.91 paise/kWh delivered]
Maximum demand = 25000 kW ; Load factor = 0.4 ; Coal 16. A 100 MW, steam power station is estimated to cost
consumption = 0.86 kg/kWh ; Boiler efficiency = 85% ; ` 20 crores. The operating expenses are estimated as
Turbine efficiency = 90% ; Price of coal = ` 55 per tonne. follows :
Determine the following : Cost of fuel and oil = ` 140 lacs per annum
(i) Thermal efficiency of the station. Transportation and storage = ` 20 lacs per annum
(ii) Coal bill of the plant for one year. Salaries and wages = ` 20 lacs per annum
[Ans. (i) 76.5%, (ii) ` 4143480] Miscellaneous = ` 20 lacs per annum
10. The daily load curve of a power plant is given by the table Reckoning interest and depreciation at 10% of the capital
below : cost, calculate the cost of generation per unit, if the average
Time : 12 2 4 6 8 10 12 2 4 6 8 10 12 load factor of the power station is 0.6.
Load 2 2.5 3 4 6 6.5 6.5 5 6 8 9 5 2 What economics could be affected if the load factor was
(MW) : improved to 0.8, the operating expenses increasing by only
(i) Find the daily load factor. 10% thereby.
(ii) All loads in excess of 400 kW are carried out by unit [Ans. 6 p/kWh, 21% reduction in cost of generation]
No. 2 rated at 600 kW. Find its use factor. 17. A steam station has two 110 MW units. Following cost
[Ans. (i) 0.814, (ii) 0.417] data are given :
11. The annual peak load on a 30 MW power station is 25 MW. Particulars Unit A Unit B
The power station supplies load having maximum Capital cost ` 2000 per kW ` 2500 per kW
demands of 10 MW, 8.5 MW, 5 MW and 4.5 MW. The Fixed charge rate 10 per cent 10 per cent
annual load factor is 0.45. Find : Capacity factor 0.55 0.6
(i) Average load (ii) Energy supplied per year
Fuel consumption 1 kg/kWh 0.9 kg/kWh
(iii Diversity factor (iv) Demand factor.
Fuel cost ` 80 per 1000 kg ` 80 per 1000 kg
[Ans. (i) 11.25 MW, (ii) 98.55 × 106 kWh,
(iii) 1.12, (iv) 0.9] Annual cost of 20 per cent of 15 per cent of
operating, labour annual cost annual cost
12. A generating station supplies the following loads :
maintenance and
15 MW, 12 MW, 8.5 MW, 6 MW and 0.45 MW. The station supplies
has a maximum demand of 22 MW. The annual load factor
Utilisation factor 1 1
of the station is 0.48. Calculate :
Calculate the following :
(i) The number of units supplied annually,
(ii) The diversity factor. (iii) The demand factor. (i) Annual plant cost and generation cost of unit A.
[Ans. (i) 92.5 × 106 kWh, (ii) 1.907, (iii) 0.525] (ii) Annual plant cost and generation cost of unit B.
ECONOMICS OF POWER GENERATION 487
Cost Steam power plant Hydro power plant Nuclear power plant
25. An input output curve of a 10 MW thermal station is given Find the most economical loading when the load taken by
by an equation both units is 30 MW. [Ans. L1 = 20 MW, L2 = 10 MW]
I = 106(18 + 12L + 0.5L2) kcal/hour 30. Two electrical units used for the same purpose are
where I is in kcal/hour and L is the load on power plant in compared for their economical working :
MW. (i) Cost of Unit-1 is ` 5000 and it takes 100 kW.
Find : (i) The load at which the efficiency of the plant will (ii) Cost of Unit-2 is ` 14000 and it takes 60 kW.
be maximum. Each of them has a useful life of 40000 hours. Which unit
(ii) The increase in output required to increase the station will prove economical if the energy is charged at ` 80 per
output from 5 MW to 7 MW by using the input-output kW of maximum demand per year and 5 p. per kWh ?
equation and by incremental rate curve. Assume both units run at full load.
[Ans. (i) 6 MW, (ii) 36 × 106 kcal/hour] [Ans. Unit-1 : ` 6.039 ; Unit-2 : ` 3.898,
26. The input-output curve of a 60 MW power station is given Unit-2 is more economical]
by : 31. A new industry requires maximum demand of 800 kW at
I = 106(8 + 8L + 0.4L2) kcal/hour 30% load factor. The following two power supplies are
where I is the input in kcal/hour and L is load in MW. available :
(i) Determine the heat input per day to the power station (i) Public supply charges ` 50/kW of maximum demand
if it works for 20 hours at full load and remaining and 4 p. per kWh.
period at no load. Capital cost = ` 80000
(ii) Also find the saving per kWh of energy produced if Interest and depreciation = 10 per cent.
the plant works at full load for all 24 hours generating (ii) Private oil engine generating station.
the same amount of energy. Capital cost = ` 30000
[Ans. (i) 38592 × 106 kcal/day, (ii) 4000 kcal/kWh] Interest and depreciation = 12 per cent
27. The incremental fuel costs for two generating units 1 and Maintenance and labour charges
2 of a power plant are given by the following equations : = 1 p. per kWh energy generated
dF1 Fuel consumption = 0.35 kg/kWh
= 0.06P1 + 11.4
dP1 Cost of fuel = 8 paise/kg.
dF2 Find which supply will be more economical ?
= 0.07P2 + 10 [Ans. (i) 6.3 p/kWh, (ii) 5.1 p/kWh ;
dP2
where P is in megawatts and F is in rupees per hour. oil engine generation is more preferable]
(i) Find the economic loading of the two units when the 32. A load having a maximum demand of 80 MW and a load
total load to be supplied by the power station is factor of 40% may be supplied by one of the following
150 MW. schemes :
(ii) Find the loss in fuel costs per hour if the load is equally (i) A steam station capable of supplying the whole load.
shared by the two units. (ii) A steam station in conjunction with pump-storage
[Ans. (i) P1 = 70 MW, P2 = 80 MW, (ii) ` 1.63 per hour] plant which is capable of supplying 120 × 106 kWh
energy per year with a maximum output of 30 MW.
28. The incremental fuel costs for two generating units 1 and
Find out the cost of energy per unit in each of the two
2 of a power plant are given by the following equations :
cases mentioned above. Use the following data :
dF1
= 0.065P1 + 25 Capital cost of steam station = ` 1800/kW of installed
dP1 capacity ; Capital cost of pump storage plant = ` 1200/kW
dF2 of installed capacity ; Operating cost of steam plant = 0.5
= 0.08P2 + 20 p/kWh ; Operating cost of pump storage plant = 0.4 p./
dP2
where F is fuel cost in rupees per hour and P is power kWh.
output in MW. Find : Interest and depreciation together on capital invested
(i) the economic loading of the two units when the total should be taken as 12 per cent.
load supplied by the power plants is 160 MW. Assume that no spare capacity is required.
(ii) the loss in fuel cost per hour if the load is equally [Ans. (i) 11.16 p./kWh, (ii) 8.42 p./kWh]
shared by both units. 33. The monthly electricity consumption of a residence can
[Ans. (i) P1 = 53.5 MW, P2 = 106.5 MW, (ii) ` 35/hour] be approximated as under :
29. Two steam turbines each of 20 MW capacity take a load of Light load : 4 tube lights 40 watts each working for 3 hours
30 MW. The steam consumption rates in kg per hour for daily ; Fan load : 4 fans 100 watts each working for
both turbines are given by the following equations : 5 hours daily ; Refrigerator load : 1 kWh daily ; Miscella-
S1 = 2000 + 10L1 – 0.0001L12 neous load : 1 kW for one hour daily.
S2 = 1000 + 7L2 – 0.00005L22 Find the monthly bill at the following tariff :
L represents the load in kW and S represents the steam First 15 units : ` 0.50/kWh, Next 25 units : ` 0.40 per
consumption per hour. kWh ; Remaining units : ` 0.30 per kWh ; Constant charge :
` 2.50 per month. Discount for prompt payment = 5% .
[Ans. ` 45.20]
ECONOMICS OF POWER GENERATION 489
34. An industrial undertaking has a connected load of 110 kW. Determine the following :
The maximum demand is 90 kW. On an average each (i) The annual energy generated.
machine works for 60 per cent time. Find the yearly (ii) The cost of generation (per kWh).
expenditure on electricity if the tariff is : [Ans. (i) 6.3 × 106 kWh/year, (ii) 27 paise/kWh]
` 1000 + ` 100 per kW of maximum demand per year 38. The following data relate to a steam power station of
+ ` 0.10 per kWh. [Ans. ` 67186] 120 MW capacity which takes 100 MW peak demand at
80% load factor :
35. A Hopkinson demand rate is quoted as follows :
Annual cost towards interest and depreciation = ` 100/kW
Demand rates
installed ; Operating costs = ` 1200 × 103/year ;
First 1 kW of maximum demand = ` 5/kW/month Maintenance costs = ` 200 × 103/year (fixed) and = ` 400 ×
Next 4 kW of maximum demand = ` 4/kW/month 103/year (variable) ; Miscellaneous costs = ` 100 × 103/
year ; Cost of coal used = ` 32/ton ; C.V. of fuel used =
Excess over 5 kW of maximum demand = ` 3/kW/month
6400 kcal/kg ; Overall efficiency of the plant = 20 per cent ;
Energy rates Steam consumption in kg/kWh = (0.8 + 3.5 × load factor).
First 50 kWh = 6 paise/kWh Determine the following :
Next 50 kWh = 4 paise/kWh (i) Coal cost per year.
(ii) Overall cost of generation (paise/kWh).
Next 200 kWh = 3 paise/kWh
[Ans. (i) ` 15 × 106/year, (ii) 4.12 paise/kWh]
Next 400 kWh = 2.5 paise/kWh 39. A power system requires a maximum load of 80 MW at
Excess over 700 kWh = 2 paise/kWh 35% load factor. It can be supplied by any of the following
schemes :
Determine : (i) The monthly bill for a total consumption
(i) A steam plant capable to supply whole load.
of 1500 kWh and a maximum demand of 12 kW. Also find
(ii) A steam plant with hydel plant where energy supplied
the unit energy cost.
by steam plant is 120 × 106 kWh/year with a maximum
(ii) Lowest possible bill for a month and corresponding load of 50 MW.
unit energy cost.
[Ans. (i) ` 79, 5.26 paise/kWh, Plant Capital cost Operating Transmission
cost cost
(ii) ` 46.33, 3.09 paise/kWh]
36. Find the cost of generation per kWh from the following Steam plant ` 600/kW installed 4.8 paise/kWh Negligible
data : Hydro plant ` 1400/kW installed 1.2 paise/kWh 0.3 paise/kWh
Capacity of the plant = 120 MW
Assume interest and depreciation at 12 per cent of capital
Capital cost = ` 1200 per kW installed
for steam plant and 10 per cent of capital for hydro plant.
Interest and depreciation = 10 per cent on capital Calculate the overall cost per kWh.
Fuel consumption = 1.2 kg/kWh (iii) If the whole load is supplied by a nuclear plant,
Fuel cost = ` 40 per tonne determine annual cost. Take capital cost of
` 2500/kW and running cost of 2.5 paise/kWh. Assume
Salaries, wages, repairs and maintenance
interest and depreciation as 10 per cent per annum.
= ` 600000 per year
[Ans. (i) 7.05 paise/kWh, (ii) 5.98 paise/kWh,
The maximum demand = 80 MW (iii) 10.67 paise/kWh]
Load factor = 40%. 40. The following data relate to a power plant of 120 MW
[Ans. 10.18 paise/kWh] capacity :
37. The following data relate to a 2200 kW diesel power Capital cost = ` 1500/kW ; Interest and depreciation =
station : 10 per cent on capital ; Annual running charges = ` 20
The peak load on the plant = 1600 kW × 106 ; Profit to be gained = 10 per cent of the capital ; The
energy consumed by the power plant auxiliaries = 5 per
Load factor = 45% cent of generated ; The annual load factor = 0.6 ; Annual
Capital cost per kW installed = ` 1000 capacity factor = 0.5.
Annual costs = 15 per cent of capital Calculate the following :
Annual operating costs = ` 60000 (i) The reserve capacity.
Annual maintenance cost : (ii) The cost of generation per kWh.
(i) Fixed = ` 10000 [Ans. (i) 20 MW, (ii) 9.3 paise/kWh]
(ii) Variable = ` 20000 41. A small generating unit of 5,000 kW capacity supplies
Cost of fuel = ` 0.4 per kg the following loads :
Cost of lubricating oil = ` 1.25 per kg (i) Street-light load with maximum demand of 200 kW
C.V. of fuel = 10000 kcal/kg at 0.3 load factor.
(ii) Small industrial load with maximum demand of
Consumption of fuel = 0.5 kg/kWh
1800 kW at a load factor of 0.5.
Consumption of lubricating oil = 0.0025 kg/kWh
490 POWER PLANT ENGINEERING
(iii) Domestic consumers with a maximum demand of 45. A 30 H.P. motor connected to a condensate pump has been
3000 kW at a load factor of 0.2. burnt beyond economical repairs. Two alternatives have
Find the overall energy rate for each type of consumer been proposed to replace it by :
using the following data :
Capital cost of the plant = ` 1,800/kW of installed capacity Cost at full load at half load
Total running cost = ` 6,20,000 per year Motor A ` 6000 90% 86%
Annual rate of depreciation and interest on capital cost is Motor B ` 4000 85% 82%
10%.
[Ans. (i) 11.4 paise/kWh, (ii) 8.65 paise/kWh, The life of each motor is 20 years and its salvage value is
(iii) 14.8 p/kWh] 10 per cent of the initial value. The rate of interest is 5 per
42. The following data relate to a 15 MW thermal plant : cent annually. The motor operates at full load for 25 per
Capital cost of plant = ` 1200/kW ; Interest, insurance cent of the time and at half load for the remaining period.
and depreciation = 10% of the plant ; Capital cost of The annual maintenance cost of motor A is ` 420 and
primary and secondary distribution = ` 15 × 105 ; Interest, that of motor B is ` 240. The energy rate is 10 paise/kWh.
insurance and depreciation on the capital cost of primary Which motor will be economical ?
and secondary distribution = 5% of capital cost ; Plant [Ans. Motor A ; Total cost : Motor A = ` 14,777/year
maintenance cost = ` 80 × 103 per year ; Maintenance cost Motor B = ` 15135/year]
of primary and secondary equipments = ` 2 × 105 per year ; 46. The following proposals are under consideration for
Salaries and wages = ` 6 × 105 per year ; Consumption of an industry which has a maximum demand of 50 MW
coal = 40 × 103 tonnes per year ; Cost of coal = ` 80 per and a load factor of 0.4.
tonne ; Dividend to stockholders = ` 12 × 105 per year ;
(i) A steam plant having an initial cost of ` 1000/kW and
Energy loss in transmission = 10% ; Diversity factor = 1.6 ;
maintenance cost is 2 paise/kWh. The coal of C.V. of
Load factor = 0.8 ; Maximum demand = 14 MW.
6150 kcal/kg is used. The overall efficiency of the plant
Devise a two-part tariff and find the average cost per kWh. is 25 per cent.
[Ans. Fixed charge per kW = 146, charge for energy (ii) A hydro-plant having a capital cost of ` 3000/kW and
consumption = 4.63 paise/kWh ; running cost of 0.5 paise/kWh.
Average cost of supply = 8.1 paise/kWh] Assuming interest and depreciation rate of 12 per cent
43. The following data relate to a 12 MW capacity thermal for steam plant and 9 per cent for hydro-plant, determine
plant : the price of coal above which steam station is
Peak load = 10 MW uneconomical. [Ans. ` 49.7/ton]
Annual load factor = 70% 47. An industrial consumer has a choice between low and high
Cost of the plant = ` 700/kW installed capacity voltage supply available at the following rates :
Interest, insurance and depreciation High voltage : ` 45/kW per year + paise 3.5/kWh
= 10 per cent of the capital cost Low voltage : ` 47/kW per year + paise 4/kWh
Cost of transmission and distribution system In order to have high voltage supply, consumer has to
= ` 300 × 103 install his own transformer which costs ` 100/kW. The
losses in the transformer are 3 per cent of full load.
Interest, depreciation on distribution system
Determine the number of working hours per week above
= 5 per cent
which the high voltage supply will be economical. Assume
Operating cost = ` 300 × 103 per year interest and depreciation 10 per cent of capital and
Cost of coal = ` 50/ton working weeks per year 50. Assume the load of the
Plant maintenance cost consumer as 1 MW. [Ans. 49 hours per week]
= ` 25,000 per year (fixed) 48. The expected annual cost of power system supplying the
= ` 35,000 per year (running) energy to 40,000 consumers is tabulated below :
Coal used = 30,000 tons/year. Fixed charges = ` 2400 × 103
Assume transmission and distribution costs are to be Energy charges = ` 1716 × 103
charged to generation.
Consumer charges = ` 210 × 103
(i) Design a two-part tariff.
Profit = ` 168 × 103
(ii) Determine overall cost of generation in paise/kWh.
[Ans. (i) ` 88/kW + 3 paise/kWh, (ii) 4.43 paise/kWh] Maximum demand = 5000 kW
44. Determine the load factor at which the cost of supplying a Diversity factor =4
unit of electricity is same in Diesel station as in a Steam Energy supplied = 17 × 106 kWh.
station if the respective annual fixed and running charges Devise a three-part tariff allowing 25% of the profit in
are as given below :
fixed charges, 50% in energy charges and remaining 25%
Diesel : ` (30/kW + 0.05/kWh)
in customer charges.
Steam : ` (120/kW + 0.0125/kWh). [Ans. 0.275]
[Ans. ` 122/kW per year + 11 paise/kWh
+ ` 6.3 per consumer per year]
ECONOMICS OF POWER GENERATION 491
Draw the load curve and find out the load factor of the Overall efficiency of the plant
power plant. If the load above 50 MW are taken by a stand- = 20%
by unit of 30 MW capacity, find out the load factor of the Steam consumption in kg/kWh
stand by unit. = (0.8 + 3.5 × L.F.)
12. (a) Explain the principle of circuit interruption and its Determine (i) costs per year, and (ii) overall cost of
application in circuit brakers. Define the ‘interruption generation paise/kWh.
capacity’ and ‘recovery voltage’ of a circuit braker. (c) Explain the different methods used for finding out the
(b) What are the advantages of combined operation of depreciation cost of the power plant.
power plants in a power system ? Explain with 15. (a) Discuss the methods of determining the depreciation
examples. of electrical power plant.
13. (a) Explain the effect of variable load on power plant (b) The following data for a 2200 kW diesel power station
operation and power plant design. is given. The peak load on the plant is 1600 kW and
(b) The following data relate to a 10 MW thermal station : its load factor is 45% :
Cost of plant = ` 3,000 per kW Capital cost/kW installed = ` 1000
Interest and taxes on cost of plant Annual costs = ` 15% of capital
= 8% per annum Annual operating costs = ` 60,000
Depreciation of plant = 5% per annum Annual maintenance costs = Fixed ` 10,000
Cost of primary distribution = Variable ` 20,000
= ` 800000 Cost of fuel = ` 0.4 per kg
Interest, taxes, depreciation on Cost of lubricating oil = ` 1.25 per kg
cost of primary distribution system
C.V. of fuel = 10,000 kcal/kg
= 5%
Consumption of fuel = 0.5 kg/kWh
Cost of coal with transportation
1
= ` 100 per tonne Consumption of lubricant oil = kg/kWh
400
Operating cost = ` 800000 per annum Determine (i) the annual energy generated, and (ii) the
Plant maintenance cost (i) fixed cost of generation `/kWh.
= ` 40000 per annum 16. (a) Explain with a neat sketch the water cooling system
Plant maintenance cost (ii) variable in diesel power plants using water softening plant and
= ` 50000 per annum cooling tower.
Installed capacity of plant (b) The annual costs of operating a 25 MW thermal plant
are given below :
= 10 MW
Capital cost of plant = ` 1200/kW
Maximum demand = 9 MW
Interest + insurance + depreciation
Annual load factor = 70% = 10% of plant cost
Consumption of coal per annum Capital cost of primary and secondary distribution
= 25000 tonnes. = ` 15 × 105
Find : (i) the fixed cost of power generation per kW per Interest + insurance + depreciation on the capital cost of
annum ; (ii) the total cost of power generation per kWh. primary and secondary distribution
Cost of primary distribution is chargeable to generation. = 5% of capital cost
14. (a) What is meant by powers plant economics ? What are Plant maintenance cost
the fixed and operating costs ? = ` 80 × 103 per year
(b) The following data relate to steam power station of
Maintenance cost of primary and secondary equipment
120 MW capacity which takes 100 MW peak demand
= ` 2 × 105 per year
at 80% load factor (L.F.).
Salaries and wages = ` 6 × 105 per year
Annual cost towards the interest and depreciation
= ` 100/kW installed Consumption of coal = 40 × 103 tonnes per year
Annual operating costs Cost of coal = ` 80 per tonne
= ` 1200 × 103 Dividend to stockholders
Annual maintenance costs = ` 12 × 105 per year
= ` 200 × 102 (fixed) Energy loss in transmission
= ` 400 × 103 (variable) = 10%
Annual miscellaneous costs Diversity factor = 1.5
= ` 100 × 103 Load factor = 80%
Cost of coal used = ` 32/tonne Maximum demand = 14 MW.
Calorific value of fuel used Find the following :
= ` 6400 kcal/kg (i) Total fixed cost ; (ii) Total variable charges ; (iii) Charges
for energy consumption ; (iv) Average cost of supply.
ECONOMICS OF POWER GENERATION 493
17. (a) Explain load-duration curve. What are annual 19. (a) Define ‘diversity factor’ and state the advantages of
operating costs ? What are the factors that influence the diversity load on a power supply system.
the depreciation of capital equipment ? (b) A load having a maximum demand of 100 MW and a
(b) The estimated total annual operating costs and capital load factor of 30% may be supplied by one the following
charges for two power stations are given by the schemes :
following expressions : Scheme A : A steam thermal plant capable of supplying
Annual cost for station A : the whole load.
` (105 + 60 kW + 0.01 kWh) Scheme B : A steam thermal plant in conjunction with
Annual cost for station B : a pump storage plant capable of supplying
` (6 × 104 + 35 kW + 0.02 kWh) 108 kWh of energy per year with a maximum
load of 40 MW.
where kW represents the capacity of the station and kWh
represents the total annual energy generated. Find the cost of energy per unit in each case.
The stations are to be used to supply a common load having Use the following data :
annual load duration curve approximated by a straight Capital cost of the steam plant
line, maximum and minimum loads being 50 MW and zero = ` 3000/kW of installed capacity
respectively. Capital cost of the pump storage plant
Find the following : = ` 2000/kW of installed capacity
(i) Which station should be used to supply the peak load ? Operating cost of steam plant
(ii) What should be its installed capacity ? = 20 p/kWh
(iii) For how many hours per year should it be in operation Operating cost of pump storage plant = 2 p/kWh
to give the minimum total cost per unit generated ?
Interest and depreciation together on capital cost for both
Calculate also the total cost per unit generated under these
schemes = 15%
conditions.
Assume reserve capacity of 20 MW for the steam plant in
18. (a) What are fixed costs and operating costs ?
each scheme.
(b) Name the major items of fixed costs and operating
costs. 20. How do you define load factor, plant use factor and capacity
factor ? What is the importance of diversity factor in the
(c) A new housing development is to be added to the lines
design of a steam power plant ?
of a public utility system. There are 1000 apartments,
each having a connected load of 4 kW ; also stores and 21. (a) Explain the terms ‘Maximum Demand’ and ‘Load
services are included as given below : Factor’ with reference to a ‘Power System’.
(b) A load having a maximum demand of 100 MW at 30%
Stores Connected Demand load factor may be supplied by one of the following
or load factor schemes :
Services in kW in per cent (i) A steam plant capable of supplying the whole load ;
Laundry, Drug stores, etc. 50 60 (ii) A steam plant in conjunction with a pumped storage
1 Restaurant 60 52 plant capable of supplying 106 kWh energy per year
with a maximum load of 40 MW.
2 Churches 20 each 56
Using the following data, find the most economic scheme
3 Theatre 100 50 among the two
The demand factor of the apartments is 45 per cent. The Capital cost of steam station is ` 1000/kW of installed
group diversity factor of the residential load for this system capacity.
is 3.5 and the peak diversity factor is 1.4. The commercial Capital cost of pumped storage plant is ` 700/kW of
load group diversity factor is 1.5 and the peak diversity installed capacity. Operating cost of steam station = 2.5
factor is 1.1. NP/kWh. Interest and depreciation together on capital cost
Find the increase in peak demand on the total system is 15%. Assume no reserve capacity is required for both
delivery from the station bus resulting from addition of the schemes.
this development on the distribution system. Assume line
losses as 5 per cent of delivery energy.
10
Non-Conventional Power
Generation and Direct
Energy Conversion
10.1. Introduction to energy and energy sources—Energy—Non-conventional energy sources. 10.2. Wind power plants—
Introduction—Characteristics of wind—Advantages and disadvantages of wind energy—Sources/origins of wind—Wind availability
and measurement—Wind power—Terms and definitions—Types of wind mills—Wind-electric generating power plant—Types of wind
machines—Utilisation aspects of wind energy—Generating systems—Wind-powered battery chargers—Wind electricity in small
independent grids—Wind electricity economics—Problems in operating large wind power generators—Considerations for selection
of site for wind energy conversion systems. 10.3. Tidal power plants—Ocean energy conversion—Ocean energy sources—
General aspects—Tidal power plants—Wave energy—Ocean thermal energy conversion (OTEC) plant. 10.4. Solar power plants—
Solar energy—General terms and introduction—Collectors in various ranges and applications—Flat plate collectors—Focusing
(or concentrating) collectors—Solar pond technology—Low temperature thermal power generation—Medium temperature systems
using focusing collectors—High temperature systems—Solar farm and solar power plant. 10.5. Geothermal power plants—Geothermal
energy—Geothermal sources—Geothermal power estimates—Environmental problems—Applications of geothermal energy—
Advantages and disadvantages of geothermal energy over other energy forms—Geothermal energy in India and abroad. 10.6. Biogas
plants-Biomass—Introduction to biomass—Biomass conversion processes—Biogas plants. 10.7. Direct energy conversion
systems—Thermoelectric conversion system—Thermionic conversion system—Photovoltaic power system—Magnetohydrodynamics
(MHD) system—Electrostatic mechanical generators—Electro gas-dynamic generators (EGD)—Fuel cells—Nuclear Batteries—
Highlights—Theoretical Questions—Competitive Examinations Questions.
494
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 495
Energy :
1. Stored in earth : OP
(i) Chemically bonded : PP
(a) Oil
(b) Gas
PP Water input
(c) Coal PP
(ii) Geotherm PP Thermocycle
(iii) Atomic :
(a) Fission
PP —Steam turbo-generator
l Energy science focusses attention on the (vii) The energy is measured in Nm or in joules.
‘energy’ and ‘energy transformations’ involved (viii) The forms of energy are graded as per their
in the various other branches of science, to availability or energy content.
National economy and civilization. l The total mass and energy in the closed system
l Energy technology is the applied part of energy remains unchanged (as per law of conservation
sciences for work and processes, useful to human of energy).
society, nations and individuals.
Energy and thermodynamics :
— Energy technologies deal with plants and
processes involved in the energy transformation “Thermodynamics” is a branch of energy which deals
and analysis of the useful energy (exergy) and with conversion of heat into work or vice versa :
worthless energy (anergy) — More than 30 per cent energy conversion
— Energy technology co-relates various sciences processes involve thermodynamics, while more
and technologies than 30 per cent energy conversion processes
involve electromagnetic energy and more than
Characteristics of energy. Energy has the 30 per cent involve chemical energy.
following characteristics : In most of the energy conversion processes, First
(i) It can be stored. law and Second law of thermodynamics are applicable :
(ii) It can neither be created nor destroyed. l First law of thermodynamics relates to
(iii) It is available in several forms conservation of energy and throws light on
(iv) It does not have absolute value. concept of internal energy.
(v) It is associated with a potential. Free flow of l Second law of thermodynamics indicates the
energy takes place only from a higher potential limit of converting heat into work and introduces
to a lower potential. the principle of increase of entropy. Following
(vi) It can be transported from one system to other statements are based on this law :
system or from one place to another. — Spontaneous processes are irreversible.
496 POWER PLANT ENGINEERING
10.1.2. Non-Conventional Energy Sources The flexible 3 blades propeller was about 35 m
in diameter and produced the rated power in a
A plenty of energy is needed to sustain industrial growth
60 km/hour wind with a rotation speed of
and agricultural production. The existing sources of energy
47 r.p.m. The maximum power developed was
such as coal, oil, uranium etc. may not be adequate to meet
12 MW. In India the interest in the wind mills
the ever increasing energy demands. These conventional
was shown in the last fifties and early sixties.
sources of energy are also depleting and may be exhausted
Apart from importing a few from outside, new
at the end of the century or beginning of the next century.
designs were also developed, but these were not
Consequently sincere and untiring efforts shall have to be
sustained. It is only in last 15–20 years that
made by the scientists and engineers in exploring the
development work is going on in many
possibilities of harnessing energy from several non-
institutions. An important reason for this lack
conventional energy sources. The various non-conventional
of interest in wind energy must be that wind, in
energy sources are as follows :
India is relatively low and vary appreciably with
(i) Solar energy (ii) Wind energy seasons. These low and seasonal winds imply a
(iii) Energy from biomass and biogas high cost of exploitation of wind energy. In our
(iv) Ocean thermal energy conversion country high wind speeds are however available
(v) Tidal energy (vi) Geothermal energy in coastal areas of Sourashtra, Western
(vii) Hydrogen energy (viii) Fuel cells Rajasthan and some parts of central India. In
these areas there could be a possibility of using
(ix) Magneto-hydrodynamics generator
medium and large sized wind mills for generation
(x) Thermionic converter of electricity.
(xi) Thermo-electric power.
Applications of wind plants :
Advantages of non-conventional energy sources : Following are the main applications of wind plants :
The leading advantages of non-conventional energy
1. Electrical generation.
sources are :
1. They do not pollute the atmosphere. 2. Pumping.
2. They are available in large quantities. 3. Drainage.
3. They are well suited for decentralised use. 4. Grinding grains.
According to energy experts the non-conventional 5. Saw milling.
energy sources can be used with advantage for power
10.2.2. Characteristics of Wind
generation as well as other applications in a large number
of locations and situations in our country. The main characteristics of wind are :
1
10.2. WIND POWER PLANTS l Wind speed increases roughly as th power of
7
height. Typical tower heights are about
10.2.1. Introduction 20–30 m.
l Wind is air set in motion by small amount of l Energy-pattern factor. It is the ratio of the actual
insolation reaching the upper atmosphere of energy in varying wind to energy calculated from
earth. the cube of mean wind speed. This factor is
always greater than unity which means that
— Nature generates about 1.67 × 105 kWh of
energy estimates based on mean (hourly) speed
wind energy annually over land area of earth
are pessimistic.
and 10 times this figure over the entire globe.
— Wind contains kinetic energy which can easily 10.2.3. Advantages and Disadvantages of Wind Energy
be converted to electrical energy. Following are the advantages and disadvantages of wind
l The wind energy, which is an indirect source of energy :
energy, can be used to run a wind will which in
Advantages :
turn drives a generator to produce electricity.
Although wind mills have been used for more 1. It is a renewable energy source.
than a dozen centuries for grinding grain and 2. Wind power systems being non-polluting have
pumping water, interest in large scale power no adverse effect on the environment.
generation has developed over the past 50 years. 3. Fuel provision and transport are not required
A largest wind generator built in the past was in wind energy conversion systems.
800 kW unit operated in France from 1958–60. 4. Economically competitive.
498 POWER PLANT ENGINEERING
5. Ideal choice for rural and remote areas and areas l Wind speeds increase with height. They have
which lack other energy sources. traditionally been measured at a standard height
Disadvantages : of 10 metres where they are found to be 20–25
per cent greater than close to the surface. At a
1. Owing to its irregularity, the wind energy needs
height of 60 m they may be 30–60 per cent higher
storage.
because of the reduction in the drag effect of the
2. Availability of energy is fluctuating in nature.
surface of the earth.
3. The overall weight of a wind power system is
relatively high. 10.2.5. Wind Availability and Measurement
4. Wind energy conversion systems are noisy in Wind energy can only be economical in areas of good wind
operation. availability. Wind energy differs with region and season
5. Large areas are required for installation/ and also, possibly to an even greater degree with local
operation of wind energy systems. terrain and vegetation. Although wind speeds generally
6. Present systems are neither maintenance free, increase with height, varying speeds are found over
nor practically reliable. different kinds of terrain. Observations of wind speed are
7. Low energy density. carried out at meteorological stations, airports and
8. Favourable winds are available only in a few lighthouses and are recorded regularly with ten minute
geographical locations, away from cities, forests. mean values being taken every three hours at a height of
9. Wind turbine design, manufacture and 10 m. But airports, sometimes are in valleys and many
installation have proved to be most complex due wind speed meters are situated low and combinations of
to several variables and extreme stresses. various, other factors mean that reading can be misleading.
10. Requires energy storage batteries and/or stand It is difficult, therefore, to determine the real wind speed
by diesel generators for supply of continuous of a certain place without actual in-situ measurements.
power to load.
The World Meteorological Organization (WMO) has
11. Wind farms require flat, vacant land free from
accepted four methods of wind recording :
forests.
(i) Human observation and log book.
12. Only in kW and a few MW range ; it does not
meet the energy needs of large cities and (ii) Mechanical cup-counter anemometers.
industry. (iii) Data logger.
10.2.4. Sources/Origins of Wind (iv) Continuous record of velocity and direction.
Following are the two sources/origins of wind (a natural 1. Human observation and log book. This
phenomenon) : involves using the Beaufort Scale of wind strengths which
1. Local winds. defines visible “symptoms” attributable to different wind
2. Planetary winds. speeds. The method is cheap and easily implemented but is
often unreliable. The best that can be said of such records
1. Local winds. These winds are caused by unequal
is that they are better than nothing.
heating and cooling of ground surfaces and ocean/lake
surfaces during day and night. During the day warmer air 2. Mechanical cup-counter anemometers. The
over land rises upwards and colder air from lakes, ocean, majority of meteorological stations use mechanical cup-
forest areas, shadow areas flows towards warmer zones. counter anemometers. By taking the readings twice or three
2. Planetary winds. These winds are caused by times a day, it is possible to estimate the mean wind speed.
daily rotation of earth around its polar axis and unequal This is a low cost method, but is only relatively reliable.
temperature between polar regions and equatorial regions. The instrument has to be in good working order, it has to
The strength and direction of these planetary winds change be correctly sited and should be reliably read at least daily.
with the seasons as the solar input varies. 3. Data logger. The equipment summarizes velocity
l Despite the wind’s intermittent nature, wind frequency and direction. It is more expensive and prone to
patterns at any particular site remain technical failures but gives accurate data. The method is
remarkably constant year by year. tailored to the production of readily interpretable data of
l Average wind speeds are greater in hilly and
relevance to wind energy assessment. It does not keep a
coastal areas than they are well in land. The time series record but presents the data in processed form.
winds also tend to blow more consistently and
with greater strength over the surface of the 4. Continuous record of velocity and direction.
water where there is a less surface drag. This is how data is recorded at major airports of
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 499
permanently manned meteorological stations. The Eqn. (10.2) indicates that maximum power available
equipment is expensive and technically complex, but it from the wind varies according to square of the diameter of
retains a detailed times-series record (second-by-second) the intercept area (or square of the root diameter) normally
of wind direction and wind speed. Results are given in taken to be swept area of the aeroturbine. The combined
copious quantities of data which require lengthy and effects of wind speed and rotor diameter variations is shown
expensive analysis. in Fig. 10.1. Thus, wind machines intended for generating
10.2.6. Wind Power substantial amounts of power should have large rotors and
be located in areas of high wind speeds.
The wind power can be computed by using the concept of
kinetics. The mind mill works on the principle of converting 6
kinetic energy of the wind to mechanical energy.
“Power density” in moving air is given by 5
Pw = KUw3 W/m2 ...(10.1)
Rotor diameter, m
4
K = 1.3687 × 10–2
16 3 Rotor dia. = 60 m
Theoretically a fraction = 0.5926 of the power in
27
the wind is recoverable. This is called Gilbert’s limit or 2 40 m
Betz coefficient. Aerodynamically efficiency for converting
wind energy to mechanical energy can be reasonably
1
assumed to be 70 per cent. So the mechanical energy 20 m
available at the rotating shaft is limited to 40 per cent or
at the most 45 per cent of wind energy.
0 5 10 15
l Available wind power (Pa) may be given as : Wind speed (m/s)
1 1 1 2 3
Pa = mUw2 = . .A.UwUw2 = . D .Uw Fig. 10.1. The combined effects of variations of wind speed and
2 2 2 4
diameter.
1
= D2Uw3 watts ...(10.2)
8 l State-wise wind power potential and wind power
where, = Density of air (1.225 kg/m3 at sea level), and addition capacity (as on 31-12-2004) are given
D = Diameter (in meters), in horizontal axis in Table 10.1 and Table 10.2 respectively.
aeroturbines.
Characteristics of a good wind power site : 6. Wind farm (wind energy park). It is a zone
A good wind power site should have the following comprising several turbine-generator units,
characteristics : electrical and mechanical auxiliaries, substation,
1. High annual wind speed. control room etc.
2. An open plain or an open shore line. Wind farms are located in areas having
3. A mountain gap. continuous favourable wind. Such locations are
4. The top of a smooth, well rounded hill with gentle on-shore or off-shore away from cities and
slopes lying on a flat plain or located on an island forests.
in a lake or sea. 7. Nacelle. It is an assemblage comprising of the
5. There should be no full obstructions within a wind turbine, gears, generator, bearings, control
radius of 3 km. gear etc. mounted in a housing.
10.2.7. Terms and Definitions 8. Propeller (wheel). It is a revolving shaft with
blades. The blades are set at an angle and
1. Aerodynamics. It is the branch of science which
twisted (like thread of a screw).
deals with air and gases in motion and their
mechanical effects. 9. Hub. It is control solid part of the wheel
(propeller).
2. Wind. Air in motion.
10. Pitch angle. It is the angle between the
3. Windmill. It is the machinery driven by the wind
direction of wind and the direction perpendicular
acting upon sails used chiefly in flat districts for
to the planes of blades.
grinding of corn, pumping of water etc.
4. Wind turbine (Aeroturbine, wind machine). 11. Pitch control. It is the control of pitch angle
It is a machine which converts wind power into by turning the blades or blade tips [Fig. 10.2 (a)].
rotary mechanical power. A wind turbine has 12. Yaw control. It is the control for orienting
aerofoil blades mounted on the rotor. The wind (steering) the axis of wind turbine in the
drives the rotor and produces rotary mechanical direction of wind [Fig. 10.2 (b)].
energy. 13. Teethering. It is see-saw like swinging motion
5. Wind turbine generator unit. It is an with hesitation between two alternatives. The
assemblage of a wind turbine, gear chain, plane of wind turbine wheel is swung in inclined
electrical generator, associated civil works and position at higher wind speeds by teethering
auxiliaries. control [Fig. 10.2 (b)].
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 501
Multiblade type
Yaw
control
Pitch
(Horizontal
control
plane)
Four-blade dutch wind mill
Tower Tower
+
Savonius type
(a) (b)
0.6 Structure
system incorporated. Horizontal axis wind changes. Because their operation is independent of wind
turbines are mounted on towers so as to be above direction, vertical axis machines are called panemones.
the level of turbulence and other ground related Aerofoil blades
effects. (Catenary shape)
Guys
10.2.10. Types of Wind Machines
Wind machines (aerogenerators) are generally classified
as follows :
1. Horizontal axis wind machines
6.5 m
2. Vertical axis wind machines.
3. Small rural systems which can use energy when developments are heavily weighted in favour of CSCF system
wind is available. with alternator as the generating unit. It must be reminded
l This category has application in developing here that to obtain high efficiencies the blade pitch varying
countries with large isolated rural areas. mechanism and controls have to be installed.
— Wind turbines of electrical rating of 100 kW and
10.2.12. Generating Systems above are of constant-speed type and are coupled
The wind turbine-generator unit comprising wind turbine, to synchronous generators (conventional type).
gears and generator, converts wind power into electrical The turbine rated at less than 100 kW is coupled
power. Several identical units are installed in a wind farm. to fairly constant speed induction generators
The total electrical power produced by the wind farm is fed connected to grid and so operating at constant
frequency having their excitation VARs from the
into the distribution network or stand alone electrical load.
grid or capacitor compensators.
The choice of electrical system for an aeroturbine is
10.2.12.2. Variable speed-constant frequency (VSCF)
guided by three factors :
system
(i) Type of electrical output :
Variable-speed drive is typical for small wind generators
— D.C. used in autonomous applications, generally producing
— Variable-frequency A.C. variable frequency and variable voltage output.
— Constant-frequency A.C. The variable speed operation of wind electric system
(ii) Aeroturbine rotational speed : yields higher outputs for both low and high wind speeds.
This results in higher annual energy yields per rated
— Constant speed with variable blade pitch.
installed kW capacity. Both horizontal axis and vertical
— Nearly constant speed with simpler pitch- axis turbines will exhibit this gain under variable speed
changing mechanism. operation.
— Variable speed with fixed pitch blades. The following schemes are used to obtain constant
(iii) Utilisation of electrical energy output : frequency output :
— In conjunction with battery or other form of (i) A.C.—D.C.—A.C. link.
storage. (ii) Double output induction generator.
— Interconnection with power grid. (iii) A.C. commutation generator.
With the advent of power switching technology (viz
10.2.12.1. Constant speed-constant frequency (CSCF)
high power diodes and thyristors) and chip-based associated
system
control circuitry, it has now become possible to use VSCF
Large scale electrical energy generated from wind is expected systems. VSCF and wind electrical systems and its
to be fed to the power grid to displace fuel generated kWh. associated power conditioning system operate as shown in
For this application present economics and technological Fig. 10.8.
Variable G
Synchronous A.C. – D.C. D.C. – A.C. R
speed wind generator I
converter converter
turbine D
VSCF wind electrical systems claim the following 4. Wind turbine/Aeroturbine always operates at
advantages : maximum efficiency point (constant tip-speed
1. Significant reduction in aerodynamic stresses, ratio).
which are associated with constant-speed 10.2.12.3. Variable speed-variable frequency (VSVF)
operation. system
2. It is possible to extract extra energy in the high
The generator output is affected by the variable speed. The
wind region of the speed-duration curve.
frequency of the induced voltage depends on the impedance
3. Complex pitch changing mechanism is not of the load and speed of the prime mover. The variable
required.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 505
voltage can be converted to constant D.C. using choppers or a back-up system (diesel) is required. Loads for remote
or rectifier and then to constant A.C. by the inverters. systems of upto 6 kWh/day equivalent to an average power
consumption of 250 W with a duty cycle of 24 hours, can be
10.2.13. Wind-Powered Battery Chargers provided with battery storage.
One application of wind energy systems which is of If a diesel and wind generator are used in
considerable potential importance (to developing countries) conjunction with a grid, the diesel generator should only be
is the use of small wind generators to charge batteries for used when wind energy is absent. Problems can occur,
powering lighting, radio communication and hospital however, when the diesel generator is called on to change
equipment. Wind generators have been in use in Europe its output frequently as wind energy availability fluctuates.
and North America since the 1920s, although their use Besides decreasing the oil saving, diesel generation on this
declined considerably. basis leads to more frequent overhauls of the generator.
A battery charging system has to include the Both factors will increase costs. Several methods of
following : overcoming these problems have been tried but there is
(i) A wind powered generator not yet an established solution. Some development work
(ii) A converter has still to be done before wind generators can be run in
parallel with diesel on a routine basis.
(iii) A container for the batteries.
Fig. 10.9 shows a set-up of wind powered battery Synchronous
charging system. It is worthnoting that 12 volt batteries, machine
which are rechargeable using wind generators, can be used
Diesel
to power fluorescent tube lighting which is six times more engine
efficient than tungsten filament lamps. Such lighting opens
up a number of important development opportunities in
areas which normally have no lighting.
Rectifier Inverter Grid
10.2.16. Problems in Operating Large Wind Power 10.3. TIDAL POWER PLANTS—OCEAN
Generators ENERGY CONVERSION
The operation of large wind power generators entails the
following problems : 10.3.1. Ocean Energy Sources—General Aspects
1. Location of site. The most important factor is Ocean energy sources may be broadly divided into the
locating a site big enough which has a reasonable average following four categories :
high wind velocity.
1. Tidal energy.
Sourashtra and Coastal Regions in India are
2. Wave energy.
promising areas.
3. *Ocean thermal energy conversion (OTEC).
2. Constant angular velocity. A constant angular
velocity is a must for generating A.C. (alternating current) 4. Energy emanated from the sun-ocean system from
power and this means very sensitive governing. the mechanism of surface water evaporation by
3. Variation in wind velocity. The wind velocity solar heating i.e., hydrological cycle.
varies with time and varies in direction and also varies 10.3.2. Tidal Power Plants
from the bottom to top of a large rotor (some rotors are as
long as 50 metres). This causes fatigue in blades. 10.3.2.1. Introduction
4. Need of a storage system. At zero velocity The periodic rise and fall of the water level of sea which are
conditions, the power generated will be zero and this means carried by the action of the sun and moon on water of the
some storage system will have to be incorporated along earth is called the ‘tide’.
with the wind mill. l Tidal energy can furnish a significant portion of
5. Strong supporting structure. Since the wind all such energies which are renewable in nature.
mill generator will have to be located at a height, the The large scale up and down movement of sea
supporting structure will have to be designed to withstand water represents an unlimited source of energy.
high wind velocity and impacts. This will add to the initial If some part of this vast energy can be converted
costs of the wind mill. into electrical energy, it would be an important
6. Occupation of large areas of land. Large areas source of hydropower.
of land will become unavailable due to wind mill gardens l The main feature of the tidal cycle is the difference
(places where many wind mills are located). The whole area
in water surface elevations at the high tide and
will have to be protected to avoid accidents.
at the low tide. If this differential head could be
Inspite of all these difficulties, interest to develop utilized in operating a hydraulic turbine, the
wind mills is there since this is a clean source of energy. tidal energy could be converted into electrical
10.2.17. Considerations for Selection of Site for Wind energy by means of an attached generator.
Energy Conversion Systems Tidal power :
When a basin exists along the shores with high tides,
Following factors should be given due considerations while
the power in the tide can be hydro-electrically utilised. This
selecting the site for wind energy conversion systems :
can be realised by having a long dam across the basin and
1. Availability of anemometry data. locating two sets of turbines underneath the dam. As the
2. High annual average wind speed. tide comes in water flows into the basin one set of turbines.
3. Availability of wind curve at the proposed site. At low tide the water flows out of the basin operating
another set of turbines.
4. Wind structure at the proposed site.
Let,
5. Altitude of the proposed site.
h = Tidal range from high to low (in m), and
6. Terrain and its aerodynamic.
A = Area of water stored in the basin (in m2).
7. Local ecology. Then, energy stored in the full basin is given as :
8. Distance to roads or railways.
9. Nearness of site to local centre/users.
10. Favourable land cost.
E = gA
1
z0
h
x.dx
*The ocean thermal energy concept was proposed as early as 1881 by the French physicist Jacques d Arsonval.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 507
now flows from basin to the sea, thereby generating power. 2. Since the turbines have to work on a wide range
The plant continues to generate power till the tide reaches of head variation (due to variable tidal range)
its lowest level. the plant efficiency is affected.
A single basin plant cannot generate power 3. There is a fear of machinery being corroded due
continuously, though it might do so by using a pumped to corrosive sea water.
storage plant if the load it supplies fluctuates considerably. 4. It is difficult to carry out construction in sea.
A double basin scheme can provide power continuously or 5. As compared to other sources of energy, the tidal
on demand, which is a great advantage. The drawback is power plant is costly.
that the civil works become more extensive. In the simplest
6. Sedimentation and silteration of basins are the
double-basin scheme there must be a dam between each
problems associated with tidal power plants.
basin and the sea and also a dam between the basins,
containing the power house. One basin is maintained always 7. The power transmission cost is high because the
at a lower level than the other. The lower reservoir empties tidal power plants are located away from load
at low tide, the upper reservoir is replinshed at high tide. If centres.
the generating capacity is to be large, the reservoirs must — The first commercial tidal power station in the
be large which means that long dams would be required. World was constructed in France in 1965 across
the mouth of La Rance Estuary. It has a high
Fig. 10.12 shows a tidal power plant-double basin
capacity of 240 MW. The average tidal range at
operation.
La Rance is 8.4 m and the dam built across the
estuary encloses an area of 22 km2.
10.3.3. Wave Energy
Sluice Wave energy comes from the interaction between the winds
Upper basin
gate and the surfaces of oceans. The energy available varies with
the size and frequency of waves. It is estimated that about
10 kW of power is available for every metre width of the
wave front.
Wave energy when active is very concentrated,
therefore, wave energy conversion into useful energy can
be carried out at high power densities. A large variety of
Sluice Lower basin devices (e.g. hydraulic accumulator wave machine ; high-
gate level reservoir machine ; Dolphin-type wave-power machine ;
Dam-Atoll wave machine) have been developed for
harvesting of energy but these are complicated and fragile
in face of gigantic power of ocean storms.
Advantages and Disadvantages :
Following are the advantages and disadvantages of wave
Fig. 10.12. Tidal power plant-double basin operation. energy :
Advantages :
10.3.2.4. Advantages and limitations of tidal power 1. It is relatively pollution free.
generation
2. It is a free and renewable energy source.
Advantages : 3. After removal of power, the waves are in placed
1. Tidal power is completely independent of the state.
precipitation (rain) and its uncertainty, besides 4. Wave-power devices do not require large land
being inexhaustible. masses.
2. Large area of valuable land is not required. 5. Whenever there is a large wave activity, a string
3. When a tidal power plant works in combination of devices have to be used. The system not only
with thermal or hydro-electric system peak produces electricity but also protects coast lines
power demand can be effectively met with. from the destructive action of large waves,
4. Tidal power generation is free from pollution. minimises erosion and help create artificial
harbour.
Limitations :
1. Due to variation in tidal range the output is not Disadvantages :
uniform. 1. Lack of dependability.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 509
2. Relative scarcity of accessible sites of large wave up from the ocean depths is used for extracting the heat in
activity. the condenser.
3. The construction of conversion devices is Fig. 10.13 shows a schematic diagram of an Ocean
relatively complicated. Thermal Energy Conversion plant—OTEC.
4. The devices have to withstand enormous power
Warm surface
water
of stormy seas.
Boiler/Evaporator
5. There are unfavourable economic factors such
as large capital investment and costs of repair,
replacement and maintenance.
Problems associated with wave energy Generator
Working
collection : fluid
Turbine
Pump
The collection of wave energy entails the following
problems :
1. The variation of frequency and amplitude makes
it an unsteady source.
2. Devices, installed to collect and to transfer wave
Condenser
energy from far off oceans, will have to with
stand adverse weather conditions.
Pump
l Uptil now no major development programme for
taming wave energy has been carried but
successfully through any country. Small devices
Cold water
are available, however, and are in limited use from ocean depth
as power supplies for buoys and navigational
aids. From the engineering development point Fig. 10.13. Schematic layout of OTEC.
of view, wave energy development is not nearly It is obvious that the efficiency of the Rankine cycle
as far long as wind and tidal energy. will be low because of small temperature difference between
the hot and cold streams. Allowing for very small
10.3.4. Ocean Thermal Energy Conversion (OTEC)
temperature drops of 4 to 5°C across the boiler and the
Plant condenser, it can be shown that the Rankine cycle efficiency
The oceans cover about 70% of the global surface and are for most of the fluids under consideration will range between
particularly extensive in the tropical zones. Therefore, most 2 and 3 per cent only. Inspite of this, the concept of an
of the sun’s radiations is absorbed by sea water. Thus warm OTEC system seems to be economically attractive because
water on the ocean’s surface flows from the tropics towards both the collection and storage of solar energy is being done
poles. Cold water circulates at the ocean bottom from the free by nature.
poles to the tropics. Hence, in the tropical regions the water l In “Open cycle” (Claude cycle, steam cycle), the
temperature is around 5°C at a depth of 1000 m, whereas warm water is converted into steam in an
at the surface, it remains almost constant at 25°C (for the evaporator. The steam drives steam-turbine
first few metres because of mixing ; subsequently it generator to deliver electrical energy.
decreases and asymptotically approaches the value at the l Cogeneration OTEC plants deliver electrical
lower level). energy and fresh water.
Thus, we can employ a carnot-type process to The following points about OTEC are worth noting :
generate power between these two steady temperatures. Such 1. Each of the possible working fluids i.e., ammonia
plants are called Ocean Thermal Energy Conversion and propane has advantages and disadvantages.
Plants OTEC. — “Ammonia” has better operating character-
All the systems being proposed for construction, now istics than propane and it is much less
work on a ‘Closed Rankine cycle’ (*Anderson cycle, vapour inflammable. On the other hand ammonia
cycle) and use low boiling point working fluids like forms irritating vapour and probably could
ammonia, propane, R-12, R-22 etc. These systems would not be used with copper heat exchanger.
be located off shore on large floating platforms or inside — “Propane” is compatible with most heat-
floating hulls. The warm surface water is used for supplying exchanger materials, but is highly flammable
the heat input in the boiler, while the cold water brought and forms an explosive mixture with air.
*The closed cycle OTEC concept was proposed by Barjot in 1926. The concept was further developed by Anderson in 1992.
510 POWER PLANT ENGINEERING
l Ammonia has been used as the working fluid in — A cold duct of 700 m length with a dia. of 25 m
successful tests of the OTEC concept with closed would be required.
cycle systems.
2. Because of the low cycle efficiency the heat to be 10.4. SOLAR POWER PLANTS
transferred in the boiler and condenser is large.
In addition, the temperature difference between 10.4.1. Solar Energy—General Terms and Introduction
the sea water and the working fluid in these heat
General Terms
exchangers has to be restricted to very small
values. For these reasons, very high flow rates Solar Constant. Solar constant is the energy from the
are required for the sea water both in the boiler sun, per unit time, received on a unit area of surface
evaporator and the condenser. This results in perpendicular to the radiation, in space, at the earth’s mean
high pumping power requirements and is distance from the sun. According to Thekaekara and
reflected in the gross power outputs which are Drummond (1971) the value of the solar constant is
20–50 per cent higher than net power outputs. 1353 W/m2 (1.940 Cal/cm2 min, or 4871 kJ/m2 hr.).
A second important consequence is that both the Beam Radiation. The solar radiation received from
evaporator and condenser are much larger in size the sun without change of direction is called beam radiation.
than similar components in conventional Diffuse Radiation. It is the solar radiation received
practice. from the sun after its direction has been changed by
The materials suggested for these heat reflection and scattering by the atmosphere.
exchangers are titanium or an alloy of copper Air Mass. It is the path length of radiation through
and nickel. This is necessitated because of the the atmosphere, considering the vertical path at sea level
corrosive nature of the sea water. as unity.
3. An examination of the break up of the OTEC Zenith Angle. It is the angle between the beam
system costs shows that the cost of heat from the sun and the vertical.
exchangers plays an important role in costing ; Solar Altitude. It is the angle between the beam
they contribute about 30 to 40 per cent of the from the sun and horizontal i.e., (90-zenith angle).
total. Solar or Short-wave Radiation. It is the
Merits and Limitations of OTEC : radiation originating from the sun, at a source temperature
of about 6000 K and in the wavelength range of 0.3 to
Following are the merits and demerits of OTEC :
3.0 m.
Merits :
Long-wave Radiation. Radiation originating from
1. It is clean form of energy conversion. sources at temperatures near ordinary ambient
2. It does not occupy land areas. temperatures and thus substantially all at wavelength
3. No payment for the energy required. greater than 3 m.
4. It can be a steady source of energy since the Declination. It is the angular position of the sun
temperatures are almost steady. at solar noon with respect to the plane of the equator (north
positive).
Limitations :
1. About 30 per cent of the power generated would Solar Energy—Introduction
be used to pump water. The surface of the earth receives from the sun about
2. The system would have to withstand strong 1014 kW of solar energy which is approximately five order
convective effect of sea water ; hurricanes and of magnitude greater than currently being consumed from
presence of debris and fish contribute additional all resources. It is evident that sun will last for 1011 years.
hazard. Even though the sun light is filtered by the atmosphere
3. The materials used will have to withstand the one square metre of the land exposed to direct sun light-
highly corrosive atmosphere and working fluid. receives the energy equivalent of about 1 H.P or 1 kW.
However, this vast amount of solar energy reaching earth
4. Construction of floating power plants is difficult.
is not easily convertible and certainly is not “free”.
5. Plant size is limited to about 100 MW due to
There are two obvious obstacles to harnessing solar
large size of components.
energy. Firstly it is not constantly available on earth. Thus
6. Very heavy investment is required. some form of storage is needed to sustain a solar power
As an example for a 150 MW plant : system through the night and during periods when local
— A flow of 500 m3/s would be required ; weather conditions obscure the sun. Second the solar energy
— The heat exchangers area required will be about is diffused. Although the total amount of energy is
0.5 km2 ; enormous, the collection and conservation of solar energy
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 511
into useful forms must be carried out over a large area hot air engines, and thermoelectric generators require the
which entails a large capital investment for the conversion solar collectors to operate at high temperatures. Solar
apparatus. collectors operating at temperature above 200°C generally
Solar energy, therefore, most likely will be developed consist of parabolloid reflector as an array of mirrors
not because it is cheaper than alternative energy sources reflecting to a central target, and requiring two directional
but because these alternative sources sooner or later diurnal tracking.
(i) will be exhausted, (ii) will become increasingly move The concentrators or focusing type collectors can give
expensive, (iii) will continue to political and economical high temperatures than flat plate collectors, but they entail
control by the nations possessing them, and (iv) will produce the following shortcomings/limitations.
undesirable yet incompletely understood environmental 1. Non-availability and high cost of materials
consequences, especially on large scale that will be required required. These materials must be easily shapeable, yet
to meet projected demands even with controlled growth. have a long life ; they must be light weight and capable of
Solar energy has some good advantages in retaining their brightness in tropical weather. Anodised
comparison to the other sources of power. Solar radiation aluminium and stainless steel are two such materials but
does not contaminate environment or endanger ecological they are expensive and not readily available in sufficient
balance. It avoids major problems like exploration, quantities.
extraction and transportation.
2. They require direct light and are not operative
10.4.2. Collectors in Various Ranges and Applications when the sun is even partly covered with clouds.
Following list gives the thermal applications of solar 3. They need tracking systems and reflecting
energy and possible temperature ranges : surfaces undergo deterioration with the passage of time.
4. These devices are also subject to similar vibration
1. Long temperature and movement problems as radar antenna dishes.
(t = 100°C)
(i) Water heating U| Comparison between Flat plate and Focusing
V|
collectors :
(ii) Space heating ... Flat plate
1. The absorber area of a concentrator system is
(iii) Space cooling
(iv) Drying
W smaller than that of a flat-plate system of the same solar
energy collection area and the insolation intensity is
therefore greater.
2. Medium temperature
2. Because the area from which heat is lost to the
(100 to 200°C)
(i) Vapour engines and turbines U| surroundings per unit of the solar energy collecting area is
V|
less than that for a flat plate collector and because the
(ii) Process heating ... Cylindrical insolation on the absorber is more concentrated, the
(iii) Refrigeration
(iv) Cooking
W Parabola working fluid can attain higher temperatures in a
concentrating system than in a flat-plate collector of the
same solar energy collecting surface.
3. High temperature
3. Owing to the small area of absorber per unit of
U|
(> 200°C) solar energy collecting area, selective surface treatment
(i) Steam engines and turbines and/or vacuum insulation to reduce heat losses and improve
(ii) Stirling engine V| ... Paraboloid collector efficiency are economically feasible.
(iii) Thermo-electric generator
W Mirror arrays 4. Since higher temperatures can be achieved, the
focusing collector can be used for power generation.
The above classification of low, medium and high
temperature ranges is some what arbitrary. Heating water 5. Little or no anti-freeze is required to protect the
absorber in a concentrator system whereas the entire solar
for domestic applications, space heating and cooling and
energy collection surface requires anti-freeze protection in
drying of agricultural products (and industrial products)
a flat-plate collector.
is generally at temperature below 100°C, achieved using
flat plate collectors with one or two glass plate covers. 6. Out of the beam and diffuse solar radiation
Refrigeration for preservation of food products, heating for components, only beam component is collected in case of
certain industrial processes, and operation of engines and focusing collectors because diffuse component cannot be
turbines using low boiling organic vapours is possible at reflected and is thus lost.
some what higher temperature of 100 to 200°C and may 7. Costly orienting systems have to be used to track
be achieved using focusing collectors with cylindrical- the sun.
parabola reflectors requiring only one directional diurnal 8. Non-uniform flux on the absorber whereas flux
tracking. Conventional steam engines and turbines, stirling in flat-plate collectors is uniform.
512 POWER PLANT ENGINEERING
10.4.3. Flat Plate Collectors collectors should be such as to make their handling easy.
10.4.3.1. Description The collector will absorb the sun energy (direct as well as
diffused) and transfer it to the fluid (air, water or oil)
Fig. 10.14 shows a Flat Plate Collector which consists of
flowing within the collector. Basically, a flat plate collector
four essential components :
is effective most of time, reliable for good many years and
1. An absorber plate. It intercepts and absorbs also inexpensive.
solar radiation. This plate is usually metallic (Copper,
Use of flat mirrors in the flat plate collectors
aluminium or steel), although plastics have been used in
improves the output, permitting higher temperatures of
some low temperature applications. In most cases it is
coated with a material to enhance the absorption of solar operation. Side mirrors are used either at north and south
radiation. The coating may also be tailored to minimise edges or at east and west edges of the collector or a
the amount of infrared radiation emitted. combination of both. The mirrors may be of reversible or
non-reversible type.
A heat transport fluid (usually air or water) is used
to extract the energy collected and passes over, under or 10.4.3.2. Analysis
through passages which form an integral part of the plate.
Consider an object exposed to sun radiations of intensity
Transparent P, per unit area at the surface of the body. These radiations,
covers
Direct solar will partly be absorbed by the body, while the remaining
Diffuse will be partly transmitted and rest reflected. If we take
solar radiation radiation
the incident radiations equal to unity, then, the absorbed,
reflected, and transmitted parts of energy will add up to
unity. There parts are called absorption co-efficient,
reflection co-efficient and transmission co-efficient and
Insulation represented by the symbols , and respectively.
Using the above symbols we can write
Absorbing Fluid tube ++=1 ...(i)
surface The absorbed part of the solar radiations, which is
Fig. 10.14. Flat plate solar collector. equal to is responsible for increasing the temperature of
the body. However, the body also loses energy by
2. Transparent covers. These are one or more conduction, convection and radiation. The equilibrium
sheets of solar radiation transmitting materials and are temperature of the body will be that at which the heat loses
placed above the absorber plate. They allow solar energy from the body are equal to the absorbed radiations. For
to reach the absorber plate while reducing convection, analysis purposes, if we represent the body by a flat plate
conduction and re-radiation heat losses. and assume that the convection and conduction loses are
negligible to begin with, then at equilibrium temperature,
3. Insulation beneath the absorber plate. It
the absorbed solar radiations should be equal to the
minimises and protects the absorbing surface from heat
radiation losses from the flat plate. The radiation losses
losses. are equal to T4, where and T are the emission co-
4. Box like structure. It contains the above efficient and absolute temperature respectively of flat plate
components and keeps them in position. and is the Boltzman’s constant.
Various types of flat plate collectors have been Therefore, at equilibrium,
designed and studied. These include tube in plate, P = T4 ...(ii)
corrugated type, spiral wound type etc. Other criteria is P
single exposure, double exposure or exposure and reflector or T 4 ...(iii)
type. The collector utilizes sheets of any of the highly
From equation (iii), it is evident that comparatively
conducting material viz. copper, aluminium, or galvanized
higher equilibrium temperature will be obtained where the
iron. The sheets are painted dead black for increasing the
absorbtivity. The sheets are provided with one or more glass quantity i.e., the ratio of absorption co-efficient to
or plastic covers with air gap in between to reduce the heat emission co-efficient of the flat plate is more. However, this
transfer losses. The sides which are not exposed to solar has been demonstrated by an equation obtained under
radiation are well insulated. The whole assembly is fixed idealised condition. In the realistic conditions too, its nature
in air tight wooden box which is mounted on simple device will remain the same, but it will get modified by other
to give the desired angle of inclination. The dimensions of influencing factors.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 513
The collectors for which ratio is equal to unity are concentrated at the focus of the parabola, if the reflector is
called ‘Neutral collectors’ and those for which the ratio in the form of a trough with parabolic cross-section, the
is greater than unity are called ‘Selective collectors’. solar radiation is focused along a line. Mostly cylindrical
The amount of energy collected, however, does not parabolic concentrators are used in which absorber is placed
along focus axis [Fig. 10.15 (b)].
depend on ratio. It primarily depends on higher value of
. So to obtain higher energy collection, one should use Shield
such flat plate where absorption co-efficient is as high as Stay rods
possible.
A flat plate painted black is placed on a well
insulated base. If it is exposed to solar radiations where P
= 800 W/m2, a typical summer value for a tropical region, Mirror strips
we obtain from equation (iii) the equilibrium temperature
as 70°C. Inspite of the simplifications here, it is a fair Chain drive
estimate of the temperature reached by a black plate left Jack shaft
for a time in the tropical sun.
This method can be refined by including the
convection losses and the energy gain as a result of Absorber tube
absorption of diffused radiations by the flat plate. Glass shield
If P is the intensity of the diffused radiations and on absorber tube
the absorption co-efficient, then equation (ii) becomes Fig. 10.15. (b) Cylindrical parabolic system.
P + P = hc(T – Ta) + T 4 ...(iv)
10.4.5. Solar Pond Technology
This is valid, where the base is insulated, hence
conduction losses are neglected. Here Ta is the atmospheric Refer to Fig. 10.16.
temperature and hc is the convection heat transfer co- The vertical configuration of salt-gradient solar pond
efficient. normally consists of following three zones :
1. Adjacent the surface there is a homogeneous
10.4.4. Focusing (or Concentrating) Collectors convective zone that serves as a buffer zone between
The main types of focusing or concentrating collectors are environmental fluctuations at the surface and conductive
as follows : heat transport from the layer below. This is the upper
convective zone (UCZ).
1. Parabolic trough collector
2. At the bottom of the pond there is another
2. Mirror strip collector
convective zone, the lower convective zone or LCZ. This is
3. Fresnel less collector the layer with the highest salt concentration and where
4. Flat plate collector with adjustable mirrors the high temperatures are built up.
5. Compound parabolic concentrator. 3. For given salinites and temperatures in the upper
Fig. 10.15 (a) shows the principle of the parabolic and lower convective zones, there exists a stable
trough collector which is often used in focusing collectors. intermediate gradient zone. This zone keeps the two
Solar radiation coming from the particular direction is convective zones apart and gives the solar pond its unique
collected over the area of reflecting surface and is thermal performance. This intermediate zone provides
excellent insulation for the storage layer, while
simultaneously transmitting the solar radiation. To
maintain a solar pond in this non-equilibrium stationary
state, it is necessary to replace the amount of salt that is
transported by molecular diffusion from the LCZ to the
Sun rays
UCZ. This means that salt must be added to the LCZ, and
Focus fresh water to the UCZ whilst-brine is removed. The brine
can be recycled, divided into water and salt (by solar
Vertex distillation) and returned to the pond.
The major heat loss occurs from the surface of the
solar pond. This heat loss can be prevented by spreading a
Parabolic plastic grid over the pond’s surface to prevent disturbance
reflector by the wind. Disturbed water tends to lose heat transfer
Fig. 10.15. (a) Cross-section of parabolic trough collector. faster than when calm.
514 POWER PLANT ENGINEERING
Sun
Solar radiation
Fresh Brine
water Low salt content cool water
Lighter layer floats on top
Gradient zone
Due to the excessively high salt concentration of the pond’s absorption efficiency can reach 50% of incoming solar
LCZ, a plastic liner or impermeable soil must be used to radiation, although actual efficiencies average about 20%
prevent infiltration into the nearby ground water or soil. due to heat losses. Once the lower layer of the pond reaches
The liner is a factor that increases the cost of a solar pond. over 60°C the heat generated can be drawn off through a
A site where the soil is naturally impermeable, such as the heat exchanger and used to drive a low temperature organic
base of a natural pond or lake, or can be made impermeable Rankine cycle (ORC) turbine. This harnesses the pressure
by compaction or other means, will allow considerably lower differentials created when a low boiling point organic fluid
power costs. (or gas) is boiled by heat from the pond via a heat exchanger
The optical transmission properties and related and cooled by a condenser to drive a turbine to generate
collection efficiency vary greatly and depend on the electricity. The conversion efficiency of an organic Rankine
following : cycle turbine driving an electric generator is 5–8% (which
(i) Salt concentration. mean 1–3% from insolation to electricity output).
(ii) The quantity of suspended dust or other 10.4.6. Low Temperature Thermal Power Generation
particles. 10.4.6.1. Solar pond electric power plant
(iii) Surface impurities like leaves or debris, A low temperature thermal electric power production
biological material like bacteria and algae. scheme using solar pond is shown schematically in
(iv) The type of salt. Fig. 10.17. The energy obtained from a solar pond is used
It becomes obvious that much higher efficiencies and to drive a Rankine cycle heat engine. Hot water from the
storage can be achieved through the utilization of refined bottom level of the pond is pumped to the evaporator where
the organic working fluid is vapourized. The vapour then
or pure salt whenever possible, as this maximizes optical
flows under high pressure to the turbine where it expands
transmission.
and work thus obtained runs an electric generator
The solar pond is an effective collector of diffuse, as producing electricity. The exhaust vapour is then condensed
well as direct radiation, and will gather useful heat even in a condenser and the liquid is pumped back to the
on cloudy or overcast days. Under ideal conditions, the evaporator and the cycle is repeated.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 515
Cooling tower
Sun
Hot water
Condenser
Cold water
Cold
brine
Turbine Generator
Electrical
output
plate
power plant collectors
Solar r
10.4.7. Medium Temperature Systems Using Focusing In case of central receiver “solar tower” concentra-
Collectors tors, temperature can reach thousands of degrees celsius,
since a field of reflectors (heliostats) are arranged
A circular or rectangular parabolic mirror can collect the separately on sun-tracking frames to reflect the sun on to
radiation and focus it on to a small area, a mechanism for a boiler mounted on a central tower (Figs. 10.21, 10.22).
moving the collector to follow the sun being necessary. Such With both systems (‘solar farm’ and ‘solar tower’),
devices are used for metallurgical research where high purity a heat transfer fluid or gas is passed through the point or
and high temperatures are essential, an example being a line of insolation concentration to collect the heat and
55 m diameter collector giving about 1 MW (th) at Mont transfer it to the point of use. Such heat can be used either
Louis in Pyrenees. Smaller units having 20 m diameter directly in industrial or commercial processes or indirectly
reflector can give temperatures of 300°C over an area of in electricity production via. steam and a turbine.
about 50 m2. The collector efficiency is about 50%. On a small
Boiler
scale, units about 1 m diameter giving temperatures of about
300°C have been used for cooking purposes.
Incident
Sola Tilt solar rays
radia r
tion Adjustment
Tower
Heliostat
Fig. 10.21
Boiler Steam
out
Generator
Solar Power Plant
For a large scale production of process-heat the following
two concepts are available :
1. The solar farm. It consists of a whole field
covered with parabolic trough concentrators. Fig. 10.22. Diagram of solar tower power plant.
2. The solar tower. It consists of a central receiver The solar technologies such as the above two systems
on a tower and a whole field of tracking. that produce very hot water or steam are currently still
In case of a ‘solar farm’ temperature at the point of under development and, in general, these technologies are
focus can reach several hundred degrees celsius. Fig. 10.20 not cost competitive with conventional power sources such
shows a solar tower system. as oil or gas.
contact with these hot spots, either dry or wet steam is 2. Geopressure resources.
formed. By drilling holes to these locations, hot water and 3. Petro-thermal or hot dry rocks (HDR).
steam can be tapped and these can be used for power
generation or space heating. 4. Magma resources.
Geothermal energy is primarily energy from the 5. Volcanoes.
earth’s own interior, it is classified as renewable because The hydro-thermal convective systems are best
the earth’s interior is and will continue in the process of resources for geothermal energy exploitation at present.
cooling for the indefinite future. Hence, geothermal energy Hot dry rock is also being considered.
from the earth’s interior is almost inexhaustible as solar Fig. 10.24 shows a dry-steam open system used in
or wind energy, so long as its sources are actively sought
Larderello (Italy) and Greyser (U.S.A.).
and economically tapped. Geothermal energy can be used
for heat and power generation. Geothermal energy is Fig. 10.25 shows a flash steam open type system
present over the entire extent of earth’s surface except that used in Cerro Prietol Mexico, Otake (Japan).
it is nearer to the surface in the volcanic areas. Heat Fig. 10.26 shows a hot water closed (Binary) system
transfer from the earth’s interior is by three primary under development in U.S.S.R. and U.S.A.
means :
(i) Direct heat conduction ;
(ii) Rapid injection of ballistic magma along natural
Steam
rifts penetrating deep into earth’s mantle ; and
turbine
(iii) Bubble like magma that buoys upwards towards
the surface. Generator
Fig. 10.23 shows a schematic diagram depicting how
hot springs are produced through hot magma (molten
mass), the fractured crystalline rocks, the permeable rocks
and percolating ground water.
Condenser
Pump
Condensed steam
to re-injection well
Dry
steam
Hot spring
0 Boiling begins Geothermal zone
Permeable rocks
Pure water
Bac
Depth (Metres)
Water with
Fig. 10.24. Dry-steam open system.
k flo
dissolved gases
3000
wo
f wa
Generator
Crystalline rocks
ter
Steam
Steam
turbine
t flow Heat flow
Hea
Brine
ser
Turbine
“base-load power plants”. These kind of plants
are primarily entering the market where modest
Heat exchanger Pump sized plants are needed with low capital cost,
short construction period and life-long fuel (i.e.
geothermal heat).
10.5.6. Advantages and Disadvantages of Geothermal
Energy over Other Energy Forms
Hot brine
Geothermal zone
Advantages of Geothermal Energy :
1. Geothermal energy is cheaper.
2. It is versatile in its use.
Fig. 10.26. Hot water closed (Binary) system. 3. It is the least polluting as compared to other
conventional energy sources.
10.5.3. Geothermal Power Estimates
4. It is amenable for multiple uses from a single
Although geothermal power estimates vary very widely yet resource.
rough estimate is given below : 5. Geothermal power plants have the highest
Depth Total stored energy (approximately) annual load factors of 85 per cent to 90 per cent
3 km 8 × 1021 joules compared to 45 per cent to 50 per cent for fossil
10 km 4 × 1022 joules fuel plants.
— The energy stored in hot springs = 10 per cent 6. It delivers greater amount of net energy from
of the above quantities. its system as compared to other alternative or
conventional systems.
— If the above energy is extracted from a 3 km
belt, with 1% thermal energy recovery factor, 7. Geothermal energy from the earth’s interior is
at a uniform rate of over 50 years period, almost as inexhaustible as solar or wind energy,
thermal power of 50 GW is obtained. With a so long as its sources are actively sought and
thermal electric conversion efficiency of 20% economically tapped.
only 10 GW of electric power will be obtained. Disadvantages :
10.5.4. Environmental Problems 1. Low overall power production efficiency (about
15% as compared to 35 to 40% for fossil fuel
Geothermal power plants create some environmental plants).
problems which are peculiar to them alone. The effluent
will be salty and may contain sodium and potassium 2. Drilling operation is noisy.
compounds. Additionally, in some cases lithium, fluorine, 3. Large areas are needed for exploitation of geo-
boron and arsenic compounds may be present. Such thermal energy.
effluents cannot be discharged into the existing water 4. The withdrawal of large amounts of steam or
courses unless properly treated without risking severe water from a hydro-thermal reservoir may result
pollution problems. Some effluents contain boron, fluorine in surface subsidence or settlement.
and arsenic. All these are very harmful to plants and animal
life in concentrations as low as two parts per million. 10.5.7. Geothermal Energy in India and Abroad
Suitable waste treatment plants to prevent degradation of Some progress is being made in India on tapping
water quality will have to be installed to treat these new geothermal energy on a commercial scale. Engineers from
and increased sources of pollution. the Geological Survey of India have drilled about 50 shallow
10.5.5. Applications of Geothermal Energy wells for steam in the Puga valley of the Ladakh region in
Jammu and Kashmir. It may be possible to operate a
The following are the three main applications of the steam 5 MW power station at the site. The Puga valley at an
and hot water from the wet geothermal reservoirs : altitude of 4500 metres above sea level has the most
1. Generation of electric power. promising geothermal field. The area extends to about
2. Space heating for buildings. 40 square kilometres out of which 5 sq. km is active. A
3. Industrial process heat. combination of wet and dry steam to the tune of 170 tonnes
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 519
of hot water per hour and 20 tonnes/hour of dry steam 10.6. BIOGAS PLANTS-BIOMASS
(superheated steam suitable for running steam turbines)
is available. This is enough to run a small power station to 10.6.1. Introduction to Biomass
light the homes of local population. The geothermal heat
can also be used for space heating in the Puga valley as Biomass is an organic matter from plants, animals and
the temperature in this area, especially during winter micro-organism grown on land and water and their
months, goes down to 35 degrees below freezing point. derivatives. The energy obtained from biomass is called
There are no other energy sources in Ladakh region and biomass energy.
coal, petroleum etc. have to be transported from Srinagar. Biomass is considered as a renewable source of
It can also be used for poultry farming, mushroom energy because the organic matter is generated every day.
cultivation and pashmina wool processing which need a Coal, petroleum oil and natural gas do not come in the
warmer climate. In addition, there are good deposits of category of ‘biomass’, because they are produced from dead,
borax and sulphur in this area. Sulphur in elemental form burried biomass under pressure and temperature during
is found only in this region in the whole of India. millions of year. Biomass can also be considered a form of
There are many hot water springs in India. Hot solar energy as the latter is used indirectly to grow these
water springs represent heat energy coming out of the earth plants by photosynthesis’.
from a large body of molten rock that has been pushed up Biomass resources :
into upper crust of the earth by geological forces. In North In our country, there is a great potential for
they occur in Ladakh and Himachal Pradesh. In western application of biomass as an alternate source of energy.
parts they are found in the Cambay region of Gujrat and We have plenty of agricultural and forest resources for
Maharashtra. They are also found in the Singhbhum region reproduction of biomass.
of Bihar while there are some in Assam. The water from a
The following are the biomass resources:
hot spring at Garampani, near Jawai, in Assam is so hot is
summer that rice kept in muslin bag gets worked in no 1. Concentrated wastes :
time. (i) Municipal solid
The Geological Survey of India has so far identified (ii) Sewage wood products
about 350 hot spring sites which can be explored as sources (iii) Industrial waste
of geothermal energy. The engineers have commissioned (iv) Manure at large lots.
an experimental 1 kW generator running on geothermal 2. Dispersed waste residue :
energy in the Puga area. This is the first production of
(i) Crop residue
electricity from a hot water spring in India.
(ii) Logging residue
Many countries with hot springs in their territories
have realised their potential for power and heat production. (iii) Disposed manure.
Countries like Italy, Iceland, New Zealand, the USA and 3. Harvested biomass :
the USSR have achieved remarkable progress in the (i) Standing biomass
application of geothermal energy. (ii) Biomass energy plantations.
The Italian power plant at Landerello was started The biomass sources are highly dispersed and bulky
in 1904 on a small scale but now it produces 540 MW of and contain large amount of water (50 to 90%). Thus, it is
electricity. This is equivalent to burning 1.5 million tonnes not economical to transport them over long distances, and
of oil in a year. New Zealand started exploration in 1950 as such conversion into usable energy must take place close
and the Wairakei power station now produces 175 MW, to the source, which is limited to particular regions.
which is equal to 0.7 million tonnes of oil per year. The However, biomass can be converted to liquid or gaseous
power production in California, the USA, began in 1960 fuels thereby increasing its energy density and making
and has already touched 50 MW. In the Philippines the transportation feasible over long distances.
drillers struck high pressure, high temperature steam at
about 200 m only at Tiwi, a tiny sleepy village nestled at 10.6.2. Biomass Conversion Processes
the base of the volcano Malino, in 1967. By January, 1976, The following processes are used for the biomass conversion
the first geothermal power plant at Tiwi began producing to energy or to biofuels :
55 MW. A geothermal plant with a capacity of 11 MW has 1. Direct combustion.
been in operation for nearly 20 years in USSR. The
2. Thermochemical conversion.
construction of another power plant at Mutnovsky with a
capacity of 200 MW is in progress. 3. Biochemical conversion.
520 POWER PLANT ENGINEERING
1. Direct combustion : l The process and end products depend upon the
Combustion is the process of burning in presence microorganisms cultivated and culture
of oxygen to produce heat, light and byproducts. Complete conditions. (An anaerobe is a microscopic
combustion to ashes is called incineration. organism that can live and grow without
— Wood, dung, vegetable waste can be dried and external oxygen or air ; it extracts oxygen by
burnt to provide heat or converted into low decomposing the biomass at low temperatures
calorific value gas by pyrolysis. In the pyrolysis upto 65°C, in presence of moisture).
process, the organic material is converted to l This process generates mostly methane (CH4)
gases, solids and liquids by heating to 500 to and CO2 gas with small impurities such as
900°C in the absence of oxygen. hydrogen sulphide.
— The combustion of biomass is more difficult than l The output gas obtained from anaerobic
other fuels, since it contains relatively higher
digestion can be directly burnt, or upgraded to
moisture content. Biomass is free from toxic
superior fuel gas (methane) by removal of CO2
metals and its ash.
and other impurities. The residue may consist
l The technology of “fluidised bed combustion” may
of protein-rich sludge and liquid effluents which
be used for the efficient combustion of forestry
can be used as annual feed or for soil treatment
and agricultural waste material such as
after certain processing.
sawdust, wood chips, hog fuel, rice husks, straws,
nutshells and chips. (ii) Fermentation. It is the process of decomposition
— In fluidised bed combustion of biomass, the of organic matter by micro-organisms especially bacteria
biomass is fed into a bed of hot inert particles, and yeasts.
such us sand kept in fluidised state with air at l It is a well established and widely used
sufficient velocity from below. The operating technology for the conversion of grains and sugar
temperature is normally controlled within the crops into ethanol (ethyl alcohol). Ethanol can
range 750–950°C ; ideally it is kept as high as be blended with gasoline (petrol) to produce
possible in order to maximise the rate of gasohol (90% petrol and 10% ethanol). Processes
combustion and heat transfer but low enough to have been developed to produce various fuels
avoid the problem of sintering of the bed from various types of fermentations.
particles. The rapid mixing and turbulence
within the fluidised bed enables efficient 10.6.3. Biogas Plants
combustion to be achieved with high heat
10.6.3.1. Biogas
releases, as well as effective transfer, than in a
conventional boiler. This can result in more The main source for production of biogas is wet cow-dung.
compact boiler with less number of tubes. Some of the other sources are :
2. Thermochemical conversion : (i) Sewage (ii) Crop residue
l Biomass is decomposed in thermochemical (iii) Vegetable wastes (iv) Water hyacinth
processes having various combinations of
(v) Alga (vi) Poultry droppings
temperatures and pressures.
(vii) Pig-manure (viii) Ocean kelp.
l Thermochemical conversion takes two forms :
Gasification and liquefaction. Biogas, a mixture containing 55–65% methane,
l “Gasification” takes place by heating the biomass 30–40% carbon dioxide and the rest being the impurities
with limited oxygen to produce low heating value hydrogen (hydrogen sulphide and some nitrogen), can be
gas or by reacting it with steam and oxygen at produced from the decomposition of animal, plant and
high pressure and temperature to produce human waste. It is a clean but slow-burning gas and usually
medium heating value gas. The latter may be has a heating value about 18 kJ/m3. It can be used directly
used as fuel directly or used in “liquefaction” by in cooking, reducing the demand for firewood. Moreover,
converting it to methanol (methyl alcohol), or the material from which the biogas is produced retains its
ethanol (ethyl alcohol) or it may be converted to value as fertilizer and can be returned to soil.
high heating value gas. Biogas is produced by digestion, pyrolysis or
3. Biochemical conversion. In biochemical hydrogasification. Digestion is a biological process that
conversion there are two principal conversion processes : occurs in the absence of oxygen and in the presence of
(i) Anaerobic digestion ; (ii) Fermentation. anaerobic organisms at ambient pressures and
(i) Anaerobic digestion. This process involves temperatures of 35–70°C. The container in which this
microbial digestion of biomass. digestion takes place is known as the digester.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 521
10.6.3.2. Biogas applications The biogas plants are built in several sizes, small
Biogas is a flammable fuel gas with 60% CH4 and rest CO2. (0.5 m3)/day) to very large (2500 m3/day). Accordingly, the
The gas can be upgraded by removal of CO2 with water configurations are simpler to complex.
scrubbing and the gas with high heating value can be used Biogas plants are classified as follows :
in I.C. engine. The main applications of biogas are: 1. Continuous type :
(i) Cooking. l Single stage type
(ii) Domestic lighting and heating. l Two stage type.
(iii) I.C. engines. 2. Batch type
(iv) Fuel cells–electricity can be produced by using 3. Fixed dome type (Janata model or chinese model)
biogas in a fuel cell with air as oxidant. The 4. Modified fixed dome type. This type of plant has
electrolyte is usually potassium hydroxide an additional displacement tank and water seal
(KOH). gas tank.
10.6.3.3. Types of biogas plants 5. Flexible bag type.
Biogas plant converts wet biomass into biogas (methane) 6. Floating dome type.
by the process of anaerobic fermentation. The bacteria called 10.6.3.4. Janata model gobar gas plant
anaerobe carries out digestion of biomass without oxygen
and produces methane (CH4) and carbondioxide (CO2). Constructional features. This plant consists of the
Biogas plants are very popular in India particularly in rural following parts :
areas. Cow dung, agricultural waste etc. is converted to Refer to Fig. 10.27.
methane. 1. Foundation 2. Digester
A typical biogas plant has : 3. Dome 4. Inlet chamber
— Digester ; — Inlet tank ; 5. Outlet chamber 6. Mixing tank
— Outlet tank ; — Stirrer etc. 7. Gas outlet pipe.
Mixing
tank Inlet Outlet
Initial
chamber chamber
slurry level
G a s
Max.
Slurry movement
pressure
due to gas Digester
pressure
Foundation. The foundation is the amply com- Digester. It is underground cylindrical wall portion
pacted base of the digester made of cement concrete and made of bricks, sand and cement. It is this place where
brick ballast. Its construction is so carried out that it may fermentation of dung takes place. It is also sometimes called
provide a stable foundation to the digester walls and bear ‘fermentation tank’. Two rectangular openings facing each
full load of slurry filled in the digester. It should be water- other are provided for inflow and outflow at almost middle
proof so that no percolation or water leakage takes place. of its height.
522 POWER PLANT ENGINEERING
Dome. It is a hemispherical roof of the digester ; — The earth should have adequate bearing stress
has a fixed height and forms the critical part in the to avoid any possibility of caving in or collapse
construction of Janata gobar gas plant. The gas gets of the plant.
collected in the space of the dome and exerts pressure on
Nature of soil and corresponding precautions :
the slurry in the digester.
1. Soil formed of clay :
Inlet chamber. An inlet chamber has a bell mouth
— Related problem Easy expansion and contraction
shape and is made of bricks, cement and sand. It has its
of soil as the moisture content
top opening at the ground level. Its outlet wall is made
increases and decreases.
inclined/slopy to enable the daily cattle dung feed to move
easily into the digester. — Precautions Do not disturb the primitive soil ;
Or Take measures for excess or
Outlet chamber. It is that part of the plant through
less of water ; Or Drain the
which digested slurry moves out of the digester at a surface water.
predetermined height. It has a small rectangular cross-
2. Non-uniform soil structure :
section and above this it becomes larger to a defined height.
For easy cleaning of the digester two steps are provided in e.g. partly soft soil and partly rocky
it which enable a man to climb down. Its top opening is — Related problem Crack may appear in digester
also at the ground level. Just near the top opening is wall due to uneven settlement.
provided a small outlet through which the digested/spent — Precautions Provide a uniform kind of soil
slurry flows to a compost pit. under the digester ; Or
Mixing tank. It is this tank where gobar and water — Remove a portion of the
are mixed properly in the ratio of 1 : 1 to make slurry which soft, soil and put lime
is then poured into the inlet chamber. concrete and rubble in its
Gas outlet pipe. It is a small piece of G.I. Pipe place ; Or
which is fitted at the top of the dome for conveying the gas — Remove a part of the rock and
to the points of use. A valve is fitted at its end to regulate add medium and coarse sand,
the flow of gas to the gas connections. cinders, clay or clay gravel.
Site selection. While selecting the construction of 3. Soil with high water table :
Janata gobar gas plant the following points should be given — Related problem There is an upward force on the
due consideration. digester due to pressure of
— The surface should be plane/even and be at a ground water.
higher elevation so that during rainy season the — Precautions Construct the plant in low water
water level is at least at 3 m depth. The higher seasons.
level will discourage water logging and ensure
— Dig a trench around the di-
easy discharge of spent slurry from the outlet
gester to collect the water ; this
chamber. Preferably this place should be beyond
water may be occassionally
the reach of children.
pumped out.
— The site should be as far as possible near the
cattle shed and points of gas utilisation. — Divert the ground water, if
possible, to other places e.g.,
— It should be at least 2 metres away from the
foundation of the house/building. well points.
— The sun light should be available during whole — Increase the strength of the
of the day round the year. base of the digester by in-
— The site should be at least 10–15 metres away creasing its thickness. It will
from the any water drinking source. counter act the buoyancy
— There should not be any big tree near the plant force of ground water.
whose roots may cause any harm with the Initial loading of the plant. After completion of
passage of time. the plant it is to be charged with cattle dung and water in
— There should be an easy availability of water the ratio of 1 : 1. Since Janata Plant is designed for
near the plant. 50 days retention period, therefore initial loading will
— To avoid carrying spent slurry to a very far comprise of 50 times of gobar needed for daily feed.
distance there should be some space for making Naturally to arrange such a large quantity of gobar by
compost pit. farmers who have a few cattle is a problem. This difficulty
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 523
can be overcome if the gobar is collected regularly during push/displace the slurry up in the inlet and
the period of construction of plant and by the time the plant outlet chambers while the decrease in pressure
is completed the large quantity of gobar collected can be is balanced by the return flow of slurry back in
then fed. the digester.
— Before feeding into the digester the dung should — During the process approximately equivalent
be properly mixed with water in the ratio of quantity of spent/digested slurry (top layer
1 : 1 in the mixing tank to get the slurry. slurry) is discharged from the outlet chamber
— The slurry is then fed to the digester upto the through the outlet opening ; this is so because
step provided on the Outlet chamber. Thereafter fresh/undigested slurry which is fed into the
the fermentation starts. inlet chamber is heavier than the digested/spent
— Initially allow the gas which comprises of large slurry and settles down in the digester.
percentage of a carbondioxide, oxygen and Chemistry of gas generation. In gober gas plant
hydrogen sulphide to escape since it will not the feed which comprises mainly of cattle dung is subjected
burn. to anaerobic fermentation as a result of which is produced
— The gas obtained after this release will have a combustible gas and fully matured organic manure which
right combination of methane (60%) and carbon is superior to green manure available from dung otherwise.
dioxide (40%) and burn with odourless blue The whole process of feeding fresh slurry of dung and water
flame in the gas chulha/burner/stove. and extraction of spent slurry in gobar gas plant is
— Now, at this stage start feeding the plant with continuous one.
dung slurry. The cattle dung (and other fermentable materials
— Regular, proper and careful feeding will ensure like night soil, poultry or piggery droppings etc.) when
flawless gas service. confined in a place where there is no air gives rise to mainly
How does the plant function ? two types of bacteria viz. Acid forming bacteria and
— The cattle dung and water are mixed properly Gasifying bacteria.
in the ratio 1 : 1 to form slurry which is then Acid forming bacteria convert carbohydrates,
filled in the digester upto the height of its proteins, fats into volatile acids and carbon dioxide is
cylindrical portion. produced during the process. This phase is also known as
— As soon as the fermentation of dung picks up liquification phase and is brought about by a set of
the generated gas starts accumulating in the saprophytic bacteria of means of extracellular enzyme.
dome. This gas then exerts pressure on the These bacteria are less sensitive and can exist, develop
slurry and displaces it into the Inlet and Outlet and multiply in wide range of conditions.
chambers. Consequently the slurry level in the
Liquification phase is followed by gasification phase
digester falls and rises in the Outlet chamber.
which is actively carried out by methane bacteria. They
— This fall in the level of slurry continues (if the
work upon volatile acid produced during the previous phase,
outlet pipe valve is closed) till the slurry level
with the help of intracellular enzyme and convert it into
reaches the upper ends/edges of the Inlet and
methane and carbon dioxide.
Outlet gates.
— After this stage any further accumulation of gas The whole process of gobar generation is governed
would exert pressure and start escaping through by the factors viz. temperature of substrate. Loading rate,
these gates into the atmosphere. This condition Solid concentration, Detention period, pH value, Nutrients
is indicated by bubbling and froth formation on concentration and Toxic substance etc.
the surface of the slurry in the inlet and outlet The composition of the gas produced varies with the
chambers. type of fermentable material used. In case of cattle dung
— The quantity of usable gas can be determined on an average the gas produced consists of 55 to 60%
by calculating the increase in slurry volume in methane and 40 to 45% corbon dioxide with little quantity
the inlet and outlet chambers. of hydrogen, hydrogen sulphide. With night soil the
— In the event of using gas the slurry level in the percentage may be : Methane = 65%, carbon dioxide 34%,
digester rises while that in the inlet and outlet hydrogen sulphide = 0.6% and other gas 0.4%.
comes down. Diphasic anaerobic digestion. To tide over the
— The increase in gas pressure due to increased problems generally associated with maintaining optimum
generation in comparison to its utilisation will fermentation conditions inside the digester, diphasic
524 POWER PLANT ENGINEERING
anaerobic digestion seems to be probable solution. In this 10.6.3.5. Advantages and disadvantages of ‘Fixed
system two separate digesters are used which separate the dome type’ and ‘Movable drum type’ plants
hydrogen and acid formation phases from methane A. Fixed dome type plants :
formation phase ; this separation of phases is brought out Advantages :
by kinetic control. The acid phase is operated at low
1. No maintenance problems due to absence of
retention times so that only the fast growing acidogens of
moving parts.
first hydrolysis and acid forming stages are retained in
2. Low cost.
the digester and methogens are washed out. The methane
3. Low operating cost.
phase takes place in a separate digester with the acid phase
4. Longer working life.
effluent as the feed material.
5. Due to underground construction, heat
This system facilitates provision of optimum insulation is better and therefore, rate of gas
environment conditions for growth of two physiologically production is uniform during night and day.
different types of bacteria which in turn ensures higher 6. Quantity of gas produced is higher than movable
efficiency of the process with subsequent reduction in the drum type plants.
size of digester and their cost. In this process system 7. No corrosion problem.
monitoring is also rendered easier.
8. Space above the plant can be used for other
How to accelerate gas generation. The gas purposes.
production is usually satisfactory during summer season
but it falls considerably during coldest months of the year. Disadvantages :
The gas production can be enhanced/accelerated by 1. Variable gas pressure.
following the tips given below : 2. Problem of scum formation.
— Add about 1 litre of cattle urine daily for every 3. For construction work skilled masons are
5 kg slurry fed to the plant. It will augment the required.
fermentation process and eventually increase B. Movable drum type plants :
gas production. The urine can be collected in
Advantages :
the sump connected through a drain to the
animal shed. 1. Gas pressure is constant.
— Feed back about 10% of the fresh spent/digested 2. Less scum problem.
slurry to the plant. The micro-organisms 3. No danger of explosion since there is no
available in the spent slurry will stimulate possibility of mixing of biogas and external air.
fermentation. 4. No gas leakage problem.
— Prepare the dung slurry with hot water. Water Disadvantages :
may be kept exposed to Sun during the day and 1. High cost.
be used in the evening to produce slurry. This 2. High maintenance cost.
process will prove helpful in increasing the
3. There is a loss of heat through gas holder.
temperature of slurry in the digester and
subsequently actify the bacteria to generate 4. The outlet pipe, which should be flexible,
requires regular attention.
more gas.
— Cover the plant with rice straw or gunny bags 10.6.3.6. Guidlines for fixing optimum size of a biogas
during late evenings and nights ; it will check plant
fall of temperature and keep the bacteria active The following guidline may be used to fix optimum size of
in gas generation. biogas plant :
— Add 1 kg of powdered leaves for every 50 kg 1. Type of waste.
dung fed to the plant ; it will help creating 2. Daily rate of waste to be digested.
warmer environment suitable to bacteria for 3. Digestion period.
actified fermentation. 4. Method of stirring, if any.
— Addition of poultry droppings (5 to 10%) and 5. Arrangement for raw waste feeding and
piggery waste helps to bring about increase in discharge of digested slurry.
gas generation. 6. Climatic conditions.
— Provision of a compost pit around the plant 7. Mix of raw waste.
assists in keeping the plant warm due to which 8. Water table and sub-soil conditions.
gas generation is improved. 9. Type of dome.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 525
10.7. DIRECT ENERGY CONVERSION will flow in a circuit or load connected between these ends.
The flow of current will continue as long as the heat is
SYSTEMS supplied to the hot junction and removed from the cold
The energy conversion devices that have been in use for a ends. For a given thermocouple, the voltage and electric
long time are those that accept energy as heat and produce power output are increased by increasing the temperature
mechanical work, which is transformed into electric power difference between the hot and cold ends.
distribution at large. Direct energy conversion devices
convert naturally available energy into electricity without I
an intermediate conversion into mechanical energy. (The
energy source may be thermal, solar or chemical). Until
D.C. load
now, their use has been confined to small scale, special Coolant
purpose applications, since the voltage output available
with them is rather small and no inexpensive device that
Cold Cold
is reliable like a turbine or alternator has been built.
Under this topic the following systems will be A B
discussed :
1. Thermoelectric conversion system
2. Thermionic conversion system A, B = Thermocouple
3. Photovoltaic power system Hot materials
4. Magnetohydrodynamic system
5. Electrostatic mechanical generators
Heat input
6. Electro Gas-Dynamic Generators (EGD)
7. Fuel cells Fig. 10.28. Thermoelectric generator.
8. Nuclear batteries.
In a practical thermoelectric converter, several
10.7.1. Thermoelectric Conversion System thermocouples are convected in series to increases both
voltage and power as shown in Fig. 10.29. If the output
The quest for a reliable, silent, energy converter with no
voltage is insufficient to operate a particular device or
moving parts that transforms heat to electrical power has
equipment, it can be increased, with little loss of power, by
led engineers to reconsider a set of phenomena called the
Thermoelectric effects. These effects, known for over a an inverter transformers combination. The direct current
hundred years, have permitted the development of small, generated by the thermocouples is first changed into
self contained electrical power sources. alternating current of essentially the same average by
Seebeck (thermoelectric) effect. The German means of an inverter. The alternating current and voltage
Scientist Seebeck (in 1822) discovered that if two dissimilar in then increased to the desired value with the help of a
materials are joined to form a loop and the two junctions transformer. The high voltage alternating current can be
maintained at different temperatures, an e.m.f. will be set reconverted into direct current if required, by the use of a
up around the loop. The magnitude of e.m.f. will be E = rectifier.
T where T is the temperature difference between the
D.C. load
two junctions and is the Seebeck co-efficient. This effect
has long been used in thermocouples to measure
temperatures.
This phenomenon offers one method of producing
electrical energy directly from the heat of combustion, but Cold Cold
its thermal efficiency is very low, of the order of 1 to 3 per
cent. In any heat engine, the efficiency of thermoelectric A B A B A B
generator depends upon the temperature of hot and cold
junctions.
Thermoelectric Power Generator Hot Hot Hot
Fig. 10.28 shows a schematic diagram of a thermo- Fig. 10.29. Thermocouples in series (to increase voltage).
electric power generator. The thermocouple material A and
B are joined at the hot end, but the other ends are kept The source of heat for a thermoelectric generator
cold ; an electric voltage or electromotive force is then may be a small oil or gas burner, a radio-isotope or direct
generated between the cold ends. A D.C. (Direct Current) solar radiation.
526 POWER PLANT ENGINEERING
A typical couple operating with hot and cold junction Research is being made to find more efficient
temperatures of 600°C and 200°C could be designed to give thermocouple materials. For high temperature
about 0.1 V and 2 A i.e., about 0.5 W, so that a 1 kW device applications, semiconductors based on silicon-germanium
could require about 5000 couples in series. and compounds of selenium appear to be promising.
Taking into account mechanical characteristics, To achieve higher efficiency, thermoelectric material
stability under operating conditions and ease of fabrication, should have a high value of Z and be able to operate upto
Bismuth telluride appears to be most suitable material. It very high temperature. The following points are
can be alloyed with such materials as Bismuth selenide, worthnothing in this regard :
Antimony telluride, lead selenide and tin telluride to give 1. The component thermal conductivity of
improved properties. semiconductor should be as low as possible.
Research is being carried out on the possibility of 2. The mobility of current carriers (electrons or
using thermoelectric devices within the core of a nuclear holes, should be as high as is compatible with
reactor. The hot junction would be located on the fuel condition 1).
element and the cold junctions in contact with the coolants. 3. One of the arms should consist of a purely hole
Note. A thermoelectric converter is a form of heat engine type and the other of a purely electronic type
which takes up heat at an upper temperature (hot junction) semiconductor.
converts it partly into electrical energy and discharges the 4. In the low temperature zone the impurity
remaining part at a lower temperature (cold junction). The concentration should be lower than in the higher
efficiency of a thermocouple, as is the case with other heat temperature zone.
engines, increases by increasing the upper temperature
5. So that the thermoelectric material may not
and decreasing the lower temperature. Since the lower
crack under the effect of stresses it should
temperature is usually that of environment the efficiency
of a thermocouple, practically, depends upon the hot possess the following properties :
junction temperature. (i) It should be able to resist chemical
influences such as oxidation etc.
Thermoelectric materials and their selection :
(ii) It should have good mechanical strength.
The following materials find use in the making of (iii) It should be amply elastic.
thermoelectric elements :
Material Formula Figure of merit, Z (K–1)
10.7.2. Thermionic Conversion System
Lead telluride PbTe 1.5 × 10–3 Introduction
Bismuth telluride Bi2 Te3 4 × 10–3 A thermionic converter can be analyzed from at least three
(doped with Sb or Se) different points of view :
Germanium telluride Ge Te 1.5 × 10–3 1. In terms of thermodynamics, it may be viewed as
(with bismuth) a heat-engine that uses an electron gas as a working
Cesium sulphide Ce S 1.0 × 10–3 substance.
Zinc antimonide Zn Sb 1.5 × 10–3 2. In terms of electronics, it may be viewed as a diode
(doped with silver) that transforms heat to electricity by the law of thermionic
emission.
where Z is an index used in rating thermoelectric converters. 3. In terms of thermoelectricity, it may be viewed as
It depends on the properties of thermoelectric materials a thermocouple in which an evacuated space or a plasma
used. A high value of Z is obtained by using materials of : has been substituted for one of the conductors.
(i) Large Seebeck co-efficient Regardless of the point of view adopted in analysis,
(ii) Small thermal conductivity a thermionic converter works because of the phenomenon of
(iii) Small electrical resistivity. ‘thermionic emission’. Thermionic emission implies emission
In recent times, the most commonly used material of electrons from the metal when it is heated.
for thermoelectric converters is lead telluride [a compound
of lead and tellurim, containing small amounts of either Work function ()
bismuth (N-type) or sodium (P-type)]. The efficiency of such It is defined as the energy required to extract an
a thermoelectric converter is, however, only about 5 to electron from the metal. It is measured in electron volts.
7 per cent. The value of work function varies with the nature of the
Taking into account mechanical characteristics, metal and its surface condition.
stability under operating conditions and ease of fabrication, A thermionic converter, in principle, consists of two
Bismuth telluride appears to be amply suitable material. metals or electrodes with different work functions sealed
It can be alloyed with such materials as Bismuth selenide, into an evacuated vessel. The electrode with a large work
Antimony telluride, Lead selenide and tin telluride to give function is maintained at a higher temperature than one
improved properties. with the smaller work function.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 527
Thermionic generators. Refer to Fig. 10.30. A thermionic generator, in principal can make use
of any fuel (may be fossil fuel, a nuclear fuel or solar energy)
Cold electrode
(Collector)
subject to the condition that sufficiently high temperatures
or Anode are obtainable. The thermionic conversion can be utilized
in several different situations-remote locations on the earth
and in space.
Coolant Electrons
Thermionic converter materials. The problem
of developing materials suitable for use in thermionic
D.C. load
External
Evacuated converters ranks next to the space charge control problem
vessel
in the development of efficient thermionic generators.
Following properties are desirable in materials suitable
for converters :
Emitter. A good emitter will :
(i) have high-electron emission capability coupled
Hot electrode Heat input with a low rate of deterioration.
(Emitter) (ii) have low emissivity, to reduce heat transfer by
or Cathode radiation from the emitter.
Fig. 10.30. Thermionic generator. (iii) be such that in the event some of it vapourizes
A thermionic converter/generator comprises a heated and subsequently condenses on the collector it will not
cathode (electron emitter) and an anode (electron collector) poison the collector (that is, change the collector properties,
separated by a vacuum, the electrical output circuit being thereby making it less effective).
connected between the two as shown in Fig. 10.30. The The relative importance of these properties is
heat which is supplied to the cathode raises the energy of dependent upon the type of converter being designed. It
its electrons to such a level that it enables them to escape should be noted that efficiency is a much slower rising
from the surface and flow to the anode. At the anode the function of electron emission capability if space charge is
energy of electrons appears partially as heat, removed by present than if there is no space charge.
cooling and partially as electrical energy delivered to the The work function may be reduced considerably by
circuit. Although the distance between anode and cathode an absorbed single layer of foreign atoms. This comes about
is only about one millimetre, the negative space charge with by the establishment of a dipole layer at the surface. The
such an arrangement hinders the passage of the electrons layer can be formed by atoms or molecules. This is
and must be reduced, this can be achieved by introducing essentially what happens in a cesium converter, which is
positive ions into the interelectrode space, cesium vapour designed so that cesium condenses on the emitter or
being valuable source of such ions. collector.
In order to materialise a substantial electron Collector. The main criteria for choosing a
emission rate (per unit area of emitter), and hence a collector material is that it should have as low a work
significant current output as well as a high efficiency, the function as possible. Because the collector temperature is
emitter temperature in a thermionic converter containing held below any temperature that will cause significant
cesium should be at least 1000°C, the efficiency is then electron emission, its actual emission characteristics are
10 per cent. Efficiency as high as 40 per cent can be obtained of no consequence. The lower the collector work function
by operating at still higher temperatures. Although (c), however the less energy the electron will have to
temperature has little effect on the voltage generated, the give up as it enters the collector surface. In practice the
increase in current (per unit emitter area) associated with lowest value of c that can be maintained stably is about
a temperature increase results in increase in power. 1.5 eV. For applications in which it is desirable to
Electric power (P) is the product of voltage (E) and current maintain the collector at elevated temperatures (greater
(I) i.e., P = EI. than 900 K) such as space applications, an optimum value
Anode materials should have a low work function of c may be determined. Molybdenum has been widely
e.g. barium and strontium oxides while that of the cathode used as a collector ; it is frequently assumed to have a
should be considerably higher, tungsten impregnated with work function of 1.7 eV.
a barium compound being a suitable material. Even with 10.7.3. Photovoltaic Power System
these materials temperatures upto 2000°C will be required
to secure for the generator itself, efficiencies of 30–35 per Photovoltaic generators–Historical background.
cent. Electrical outputs of about 6 W/cm2 of anode surface Edmond Becquerel in 1839 noted that a voltage was
are envisaged with about 13 W/cm2 removed by coolant. developed when light was directed onto one of the electrodes
528 POWER PLANT ENGINEERING
in an electrolytic solution. The effect was first observed in Photovoltaic cells are widely used in the following
a solid in 1877 by W.G. Adams and R.E. Day, who conducted fields :
experiments with selenium. Other early workers with solids (i) Automatic control systems ;
included Schottky, Lange and Grandahl, who did (ii) Television circuits ;
pioneering work in producing photovoltaic cells with (iii) Sound motion picture and reproducing
selenium and cuprous oxide. This work led to the equipment.
development of photoelectric exposure metres. 1954
Basic photovoltaic system for power
researchers turned to the problem of utilizing the generation
photovoltaic effect as a source of power. In that year several
Fig. 10.32 shows a basic photovoltaic system
groups including the workers at Bell Telephone integrated with the utility grid. With the help of this system
Laboratories achieved conversion efficiencies of about 6 per the generated electrical power can be delivered to the local
cent by means of junctions of P-type and N-type load.
semiconductors. These early junctions, commonly called
P-N junctions, were made of cadmium sulphide and silicon. Battery storage Local load
Later workers in the area have achieved efficiencies more
than 20 per cent by using improved silicon P-N junctions.
Photovoltaic cell. Solar energy can be directly Solar cell array
Inverter
converted to electrical energy by means of photovoltaic effect Blocking diode converter
which is defined as the generation of an electromotive force
From utility
as a result of the absorption of ionizing radiation. Energy feeder
conversion devices which are employed to convert sunlight
into electricity by the use of the photovoltaic effect are called Fig. 10.32. Basic photovoltaic system integrated
with power grid.
solar cells. A single converter cell is called a solar cell or a
photovoltaic cell. To increase the electrical power output a This system consists of the following :
number of such cells are combined and the combination is 1. Solar array 2. Blocking diode
called a solar array (or solar module). 3. Battery storage 4. Inverter converter
In a photovoltaic cell sensitive element is a 5. Switches and circuit breakers.
semiconductor (not metal) which generates voltage in
— The solar array (large or small) converts the
proportion to the light or any radiant energy incident on
insolation to useful D.C. electrical power.
it. The most commonly used photovoltaic cells are barrier
layer type like iron-selenium cells or Cu—CuO2 cells. — The blocking diode confines the electrical power
generated by the solar array to flow towards the
Fig. 10.31 shows a typical widely used photo-voltaic
battery or grid only. In the absence of blocking
cell—“Selenium cell”. It consists of a metal electrode on
diode the battery would discharge back (through
which a layer of selenium is deposited ; on the top of this a
the solar array) during the period when there
barrier layer is formed which is coated with a very thin
is no insolation.
layer of gold. The latter serves as a translucent electrode
through which light can impinge on the layer below. Under — Battery storage stores the electrical power
the influence of this light, a negative charge will build up generated through solar array.
on the gold electrode and a positive charge on the bottom — Inverter/converter (usually solid state) converts
electrode. the battery bus voltage to A.C. of frequency and
phase to match that needed to integrate with
Translucent the utility grid. Thus it is typically a D.C., A.C.
Solar radiation
layer of gold
inverter.
(Top electrode)
— Switches and circuit breakers permit isolating
– Barrier layer parts of the system, as the battery.
Layer of Limitations of photovoltaic energy converters
selenium
e.m.f.
Metal base The major factors which prohibit real photovoltaic
(Bottom converters from achieving the higher efficiencies are :
+ electrode) 1. Reflection losses on the surface.
Fig. 10.31. Photovoltaic cell. 2. Incomplete absorption.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 529
3. Utilization of only part of the photon energy for (ii) The manufacturing cost is low (possibly avoiding
creation of electron hole pairs. the need for single crystal growth).
4. Incomplete collection of electron-hole pairs. (iii) High power-to-weight ratios.
5. A voltage factor. (iv) Low array costs, because the number of
6. A curve factor related to the operating unit at connections needed will be greatly reduced.
maximum power. The example of this type of cell is cadmium sulphide
(CdS) cells. CdS cells having areas of 50 cm2 have been
7. Additional delegation of the curve due to internal
made by evaporating the semiconductor on to a flexible
series resistance.
substrate such as kapton, a metallized plastic substrate.
Fabrication of Cells : A barrier layer of copper sulphide is then deposited on top
of the CdS. Power to weight ratios of 200 watts/kg are
A. Silicon cells
claimed for such cells. These cells have low efficiency and
Silicon cells are most widely used. Next to oxygen, instability.
silicon is the most abundant element on earth, the pure
silicon used in cell manufacture is extracted from sand Advantages and disadvantages of Photovoltaic
which is mostly silicon dioxide (SiO2). The silicon required solar energy conversion
for solar cell use, because of its high purity, is expensive. Advantages :
The fabrication of silicon cells include the following (i) There are no moving parts.
steps : (ii) Solar cells are easy to operate and need little
(i) The pure silicon is placed in an induction furnace maintenance.
where boron is added to melt. This turns the (iii) They have longer life.
crystal resulting from the melt into P-type (iv) They are highly reliable.
material. (v) They do not create pollution problem.
(ii) A small seed of single crystal silicon is dipped (vi) Their energy source is unlimited.
into the melt and withdrawn at a rate slower (vii) They can be fabricated easily.
than 10 cm per hour, the resulting inset looks
(viii) They have high power to weight ratio.
like a medium sized carrot. The rate of growth
and other conditions are adjusted so that the (ix) They can be used with or without sun tracking,
making possible a wide range of application
crystal that is pulled is a single crystal.
possibilities.
(iii) Wafers are then sliced from the grown crystal
(x) They have ability to function unattended for long
by the use of a diamond cutting wheel. The slices
periods as evident in space programme.
are then lapped, generally by hand, to remove
the saw marks and strained regions. Disadvantages :
(iv) After a fine lap the slabs are etched in (i) The cost of a solar cell is quite high.
hydrofluoric acid or nitric acid to complete the (ii) The output of a solar cell is not constant, it varies
first phase of preparation of the cells. We now with the time of day and weather.
have thin slices of P-type silicon with a carefully (iii) Amount of power generated is small.
finished surface.
(v) The wafers are then sealed in a quartz tube 10.7.4. Magnetohydrodynamics (MHD) System
partly filled with phosphorous pentoxide and the Introduction. Magnetohydrodynamics (MHD), as the
arrangement is placed in a diffusion furnace name implies, is concerned with the flow of a conducting
where temperature is carefully controlled ; this fluid in the presence of magnetic and electric field. The
process causes the phosphorous to diffuse into fluid may be gas at elevated temperature or liquid like
the P-type silicon to a depth of about 10–4 cm to sodium or potassium.
10–5 cm. MHD generator is a device which converts heat
(vi) The cells are then etched in a concentrated acid energy of a fuel directly into electrical energy without a
to remove unwanted coatings that formed during conventional electric generator. MHD converter system is
manufacture. Wax or Teflon masking tape is a heat engine whose efficiency, like all heat engine, is
used to protect the surfaces not to be etched. increased by supplying the heat at the highest practical
temperature and rejecting it at the lowest practical
B. Thin film solar cells temperature. MHD generation looks the most promising
These cells have the following advantages : of the direct conversion techniques for the large scale
(i) The material cost is low. production of electric power.
530 POWER PLANT ENGINEERING
The broad classification of the MHD systems is as Open Cycle MHD systems
follows : Fig. 10.34 shows an open cycle MHD system. Here
1. Open cycle systems the fuel (such an oil, coal, natural gas) is burnt in the
2. Closed cycle systems combustion chamber, air required for combustion is
supplied from air preheater. The hot gases produced by the
(i) Seeded inert gas systems combustion chamber are then seeded with a small amount
(ii) Liquid metal systems. of an ionized alkali metal (cesium or potassium) to increase
Inverter
A.C. D.C. Electrode
Stack power supply
Seed Air D.C. Magnet
recovery supply Nozzle
Fuel
Steam Air Combus-
generator preheater tor
Removal Hot
of N2 and S gases Hot air
G
Steam
turbine
Generator
Make up
seed
the electrical conductivity of the gas. The ionization of heated in the breeder reactor is passed through the nozzle
potassium (generally potassium carbonate is used as seed where its velocity is increased. The vapour formed due to
material) takes place due to gases produced at temperature nozzle action are separated in the separator and
of about 2300–2700°C by combustion. The hot pressurised condensed and then pumped back to the reactor as shown
working fluid so produced leaves the combustion chamber in Fig. 10.35. Then the liquid metal with high velocity is
and passes through a convergent divergent nozzle. The passed through MHD generator to produce D.C. power. The
gases coming out the nozzle at high velocity then enter the liquid potassium coming out of MHD generator is passed
MHD generator. The expansion of the hot gases take place through the heat exchanger (boiler) to use its remaining
in the generator surrounded by powerful magnents. The heat to run a turbine and then pumped back to the reactor.
MHD generator produces direct current. By using an This system entails many constructional and
inverter this direct current can be converted into operational difficulties.
alternating current. Advantages of MHD systems
Closed cycle MHD systems 1. More reliable since there are no moving parts.
A liquid metal closed cycle system is shown in 2. In MHD system the efficiency can be about 50%
Fig. 10.35. A liquid metal (potassium) is used as working (still higher expected) as compared to less than
fluid in this system. The liquid potassium after being 40% for most efficient steam plants.
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 531
Reac-
ger
and electrode
9. Suitable for peak power generation and
Catch basin
emergency service.
0+
Drawbacks of MHD system
1. MHD systems suffer from the reverse flow (short Positively Negatively
circuits) of electrons through the conducting fluids around charged charged
the ends of the magnetic field. This loss can be reduced by
(i) increasing aspect ratio (L/d) of the generator, (ii) by
permitting the magnetic field poles to extend beyond the Fig. 10.36. Liquid drop electrostatic mechanical generator.
end of electrodes, and (iii) by using insulated vans in the
10.7.6. Electro Gas-Dynamic Generators (EGD)
fluid ducts and at the inlet and outlet of the generator.
2. There will be high friction losses and heat transfer The EGD generator uses the potential energy of a high
losses. The friction loss may be as high as 12% of the input. pressure gas to carry electrons from a low potential
electrode to a high potential electrode, thereby doing work
3. The MHD system operates at very high
against an electric field. A schematic diagram of EGD is
temperatures to obtain high electrical conductivity. But
shown in Fig. 10.37.
the electrodes must be relatively at low temperatures and
Carona electrode at the entrance of the duct
hence the gas in the vicinity of the electrodes is cooler.
generates electrons. This ionised gas particles are carried
This increases the resistivity of the gas near the electrodes
down the duct with the neutral atoms and the ionized
and hence there will be a very large voltage drop across
particles are neutralised by the collector electrode, at the
the gas film. By adding the seed material, the resistivity
end of the insulated duct. The working fluid in these
can be reduced.
systems are commonly, either combustion gases produced
4. The MHD system needs very large magnets and by burning of fuel at high pressures or it is a pressurised
this is a major expense. reactor gas coolant. The maximum power output from EGD
5. Coal, when used as a fuel, poses the problem of is about 10 to 30 W per channel. Hence, several thousand
molten ash which may short circuit the electrodes. Hence channels are connected in series and parallel. The voltage
oil or natural gas are considered to be much better fuels produced is very high, of the order of 1,00,000 to 2,00,000 V.
for this system. This restriction on the use of fuel makes Thus, it needs very good high voltage insulators. (Beryllium
the operation more expensive. oxide, Beo, is generally used).
532 POWER PLANT ENGINEERING
To next EGD convertor Fig. 10.38 shows a schematic diagram of a fuel cell.
The fuel gas diffuses through the anode and is oxidized,
thus releasing electrons to the external circuit ; the oxidizer
diffuses through the cathode and is reduced by the electrons
that have come from the anode by way of the external circuit.
Ionized gas
Load
s
Collector
on
ctr
electrode – +
Ele
RL V
Electrolyte
Oxidizer
Fuel in
in
Attractor
+
electrode
Carona
Oxidation
products
Ions
electrode
out
Fig. 10.38. Schematic of a fuel cell.
Fig. 10.37. Gas duct in an EGD convertor. The fuel cell is a device that keeps the fuel molecules
from mixing with the oxidizer molecules, permitting,
EGD can produce a high efficiency equal to MHD- however, the transfer of electrons by a metallic path that
steam combination. may contain a load.
Advantages of EGD over MHD systems : Of the available fuels, hydrogen has so far given
1. EGD systems operate at relatively low the most promising results, although cells consuming coal,
temperatures. oil or natural gas would be economically much more useful
2. No need for injection and recovery of seed for large scale applications.
material. Some of the possible reactions are :
3. It is self contained since it does not need a steam Hydrogen/oxygen 1.23 V
generator. 2H2 + O2 2H2O
4. Energy can be extracted till the gases reach Hydrazine 1.56 V
almost the stack temperature. N2H4 + O2 2H2O + N2
5. Does not need large quantities of condenser Carbon (coal) 1.02 V
cooling water. C + O2 CO2
EGD and MHD hold the prospects of offering the Methane 1.05 V
best solutions for high efficiency, large capacity systems
CH4 + 2O2 CO2 + 2H2O
for the production of electricity.
Hydrogen-oxygen cell :
10.7.7. Fuel Cells
The hydrogen-oxygen device shown in Fig. 10.39 is
A fuel cell is an electrochemical device in which the chemical typical of fuel cells. It has three chambers separated by
energy of a conventional fuel is converted directly and
two porous electrodes, the anode and the cathode. The
efficiently into low voltage, direct-current electrical energy.
middle chamber between the electrodes is filled with a
One of the chief advantages of such a device is that because
the conversion, at least in theory, can be carried out strong solution of potassium hydroxide. The surfaces of the
isothermally, the Carnot limitation on efficiency does not electrodes are chemically treated to repel the electrolyte,
apply. A fuel cell is often described as a primary battery in so that there is minimum leakage of potassium hydroxide
which the fuel and oxidizer are stored external to the into the outer chambers. The gases diffuse through the
battery and fed to it as needed. electrodes, undergoing reactions as shown below :
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 533
Oxygen
A nuclear battery works on the principle that beta emitter
can produce the electrical energy.
Nuclear batteries are of the following two kinds :
Electrolyte (i) High voltage atomic battery and (ii) Low voltage atomic
battery.
KOH + H2O
10.7.8.1. High voltage atomic battery
Fig. 10.40 shows the schematic diagram of a high voltage
atomic battery.
Fig. 10.39. Hydrogen-oxygen fuel cell.
–
The water formed is drawn off from the side. The Outer
electrode
electrolyte provides the (OH)– ions needed for the reaction,
Insulator
and remains unchanged at the end, since these ions are
regenerated. The electrons liberated at the anode find their
way to the cathode through the external circuit. This Direction of
electrons
transfer is equivalent to the flow of a current from the
cathode to the anode.
Such cells when properly designed and operated,
have an open circuit voltage of about 1.1 volt.
Unfortunately, their life is limited since the water formed
continuously dilutes the electrolyte. Fuel efficiencies as high
as 60 to 70% may be obtained. Inner electrode
(Spherical shell)
Advantages and disadvantages of Fuel cells
+
Advantages :
Fig. 10.40. High voltage atomic battery.
1. Conversion efficiencies are very high.
2. Require little attention and less maintenance. It consists of an inner spherical electrode on the
surface of which is deposited a powerful beta emitting (i.e.,
3. Can be installed near the use point, thus
fast electrons) substance. This is surrounded by another
reducing electrical transmission requirements spherical condenser and the inner surface of this condenser
and accompanying losses. becomes negatively charged. This acts as the outside
4. Fuel cell does not make any noise. electrode and is properly insulated at the opening. The
5. A little time is needed to go into operation. inner and outer electrodes become the –ve and +ve
terminals of the battery.
6. Space requirement considerably less in
comparison to conventional power plants. Sr90 isotope can be used since its half life is 28 years.
These batteries perform independent of the temperature
Disadvantages : unlike the accumulators whose electrolyte freezes at low
1. High initial cost. temperatures. These also supply a very steady constant
2. Low service life. potential.
This has yet to be developed on a commercial scale.
Applications of Fuel cells :
The applications of fuel cell relate to : 10.7.8.2. Low voltage atomic battery
1. Domestic use Fig. 10.41 shows a low voltage battery.
534 POWER PLANT ENGINEERING
HIGHLIGHTS
1. The periodic rise and fall of the water level of sea which 5. A thermionic converter works because of the phenomenon
are carried by the action of sun and moon on water of the of ‘thermionic emission’.
earth is called the tide. 6. ‘Photovoltaic effect’ is defined as the generation of an
2. In a single basin arrangement power can be generated electromotive force as a result of absorption of ionizing
only intermittently. radiation.
3. The solar farm consists of a whole field covered with
7. ‘MHD generator’ is device which converts heat energy of
parabolic trough concentrators and a ‘solar tower’ consists
a fuel directly into electrical energy without a conventional
of a central receiver on a tower and a whole field of
electric generator.
tracking.
4. “If two dissimilar materials are joined to form a loop and 8. A ‘fuel cell’ is an electrochemical device in which the
the two junctions maintained at different temperatures, chemical energy of a conventional fuel is converted directly
an e.m.f. will be set up around the loop”. This is called and efficiently into low voltage, direct current electrical
Seebeck effect. energy.
THEORETICAL QUESTIONS
1. List the various non-conventional energy sources. 14. Explain with a neat diagram the working of a
2. Explain with a real diagram a wind electric generating ‘Thermoelectric generator’.
power plant. 15. What is a photovoltaic cell ?
3. Write a short note on ‘Wind Electricity Economics’. 16. How are silicon cells fabricated ?
4. Name the components of a tidal power plant. 17. Write down the advantages and disadvantage of
5. Give the classification of tidal power plants. ‘Photovoltaic solar energy conversion’.
6. Give the working of a single basin tidal power plant.
18. Describe open cycle MHD system.
7. What are the advantages and limitations of tidal power
19. What is a fuel cell ?
generation ?
20. Describe a hydrogen-oxygen cell.
8. Explain with the help of a neat diagram a solar pond
electric power plant. 21. State the advantages and disadvantages of fuel cells.
9. Describe the working of a ‘solar tower plant’. 22. Write short notes on the following :
10. Give the working a geothermal plant. (a) Working of MHD generator.
11. What is ‘Thermoelectric effect’ ? (b) Fuel cells and its applications.
12. Write a short note on ‘Thermoelectric generator’. 23. Describe with the help a neat sketch, the working of a
13. Define work function. solar power plant. What are its salient features ?
NON-CONVENTIONAL POWER GENERATION AND DIRECT ENERGY CONVERSION 535
11.1. GENERAL ASPECTS engineering and specially in nuclear power station where
the complete equipment is watched and controlled from a
In power plants the instruments are used for a number of distance. Hence the importance of instrumentation in the
reasons as to operate the power plant as efficiently as power plant engineering has increased.
possible. Instruments provide accurate information for The instruments can also be classified as follows :
guidance to safe, continuous and proper plant operation. 1. Indicating instruments
The functions which the various instruments are
2. Recording instruments
required to perform are listed below :
3. Indicating and recording instruments
1. Operating guidance. The instruments provide
guidance to operate the power plant efficiently and 4. Indicating and integrating instruments
economically. 5. Indicating, recording and integrating instru-
2. Performance calculations. They render help ments.
in making performance calculations in respect of plant Commonly used instruments in a power plant
working. 1. Pressure gauges
3. Maintenance and repair guidance. As the
2. Thermometers
instruments enable us to check the internal conditions of
the equipment, thus they provide us maintenance and 3. Liquid level gauges
repair guidance. 4. Flow meters (Steam and gas)
4. Economical supervision. They enable us to 5. pH measuring instruments
supervise the plant economically. 6. Gas analysers
5. Cost allocation. The instruments extend a 7. Humidity measuring instruments
helping hand in dealing with the problems concerning costs
8. Impurity measuring instruments
accounting and cost allocations.
9. Speed measuring instruments
11.2. CLASSIFICATION OF INSTRUMENTS 10. Steam calorimeters and fuel calorimeters
11. Gong alarms
The two general classification of instruments are :
12. Electrical instruments.
1. Those employing purely mechanical methods.
(i) Ammeters (ii) Voltmeters
2. Those employing electro-mechanical methods.
(iii) Wattmeters (iv) Power factor meters
With the increase in automation electronics is being
used more widely in the field of instruments. Remote control (v) Reactive volt ampere meters
has become an established practice in power plant (vi) Ground detectors.
536
PLANT INSTRUMENTATION 537
gauge pressure
(i) Manometer gauges
Pressure
the liquid in the two legs is the same. The pressure is then The principle of the inclined manometer is explained
applied to one leg, whilst the other is open to the in Fig. 11.6. If pressure p1 = p2, then the level of liquid is
atmosphere. Under this pressure the liquid will sink in shown by LM. However, when p1 is slightly greater than
this leg and will rise in the other. As the other leg is open p2, the level in the reservoir sinks by h2, whilst level in the
to the air, therefore, the pressure on this side is known, tube rises by a greater distance h1, as shown in the diagram.
and is barometric. Now the pressure applied to the first If h is the vertical distance between the two surfaces due
leg can be calculated. This is explained with reference to to difference of pressure, then
Fig. 11.2. This consists of a water manometer. h = h1 + h2
patm also h1 = d sin
pi and h2 × A = d × a
where, A = Area of cross-section of the reservoir, and
a = Area of cross-section of the inclined tube.
hi
ha
d2
15
50
Fig. 11.2. Principle of U-tube manometer. 14
Considering equilibrium condition, we have : ° 13
40
patm + wa ha = pi + wi hi
12
pi = patm – wa ha – wi hi °
30
where, patm = Atmospheric pressure, 11
pi = Pressure over water surface in the container, ° 10
ha = Height of liquid in U-tube manometer, 20
9
hi = Difference between water surface and lower °
surface of the liquid in manometer, 10 8
wa = Specific weight of liquid, and 7
wi = Specific weight of water. °
0
6
The U-tube manometer shown in Fig. 11.3 is of the
simplest form. However, readings have to be taken at two ° 5
different places. Moreover, the deflection of the two columns 10
may not be the same. To avoid this difficulty cistern or well 4
°
type manometer is used. 20 3
Cistern manometer : 2
°
Fig. 11.4 shows a cistern manometer. The mercury 30
reservoir A is made large enough so that change of level in 1 d1
the reservoir is negligible. This form of manometer is ° 0
generally used for measuring pressures above atmospheric. 40
In this case, only one reading of the level in the column is
required. However, a zero setting is necessary. °
50
Micro-manometer : Mercury
reservoir
The U-tube manometer (discussed above) is not very
suitable for measuring very low pressures. Therefore, for Fig. 11.3. U-tube manometer. Fig. 11.4. Cistern manometer.
such purposes, precision types are required. They are called
multiplying or micro-manometers, because they multiply Also the pressure difference p i.e., (p1 – p2)
the movement of the level of the liquid. By far the most FG IJ
a
widely used type of multiplying manometer is the inclined H
= hw = d sin d
AKw
manometer. If the tube is inclined as shown in Fig. 11.5
FG a IJ
the sensitiveness of the U-tube manometer is increased.
The inclined tube causes a larger displacement of the liquid H
= dw sin
A K
along the tube for a given pressure difference. where w is the specific weight of the liquid.
PLANT INSTRUMENTATION 539
100
MM
50 30
20
10
p1
d p2
h2 b
h h1 M
L
The sensitiveness of the instrument can be varied sometimes called elastic gauges. Sometimes they are also
by changing the slope of the inclined tube. The position of called secondary instruments, which implies that they must
FG a IJ be calibrated by comparison with primary instruments such
H
the inclined tube is so arranged that sin
A Kis round as manometers etc.
figure. Some of the important types of these gauges are
The multiplication factor of the gauge is : enumerated and discussed below :
1. Bourdon tube pressure gauge
l 1
. 2. Diaphragm gauge
h sin a
A 3. Vacuum gauge.
a Bourdon Tube Type Pressure Gauge
Thus the multiplication factor depends on and
.
A A Bourdon type tube pressure gauge is used for
a measuring high as well as low pressures. A simple form of
The smaller the valves of and , the greater the
A this gauge is shown in Fig. 11.7. In this case the pressure
multiplication factor. element consists of a metal tube of approximately elliptical
11.3.3.2. Important types of pressure gauges cross-section. This tube is bent in the form of a segment of
a circle and responds to pressure changes. When one end
The manometers and U-tubes (discussed earlier) are of the tube which is attached to the gauge case, is connected
suitable for comparatively low pressures. For high pressures to the source of pressure, the internal pressure causes the
they become unnecessarily larger even when they are filled tube to expend, whereby circumferential stress i.e., hoop
with heavy liquids. Therefore, for measuring medium and tension is set up. The free end of the tube moves and is in
high pressures, we make use of elastic pressure gauges. turn connected by suitable levers to a rack, which engages
They employ different forms of elastic systems such as with a small pinion mounted on the same spindle as the
tubes, diaphragms or bellows etc. to measure the pressure. pointer. Thus the pressure applied to the tube causes the
The elastic deformation of these elements is used to show rack and pinion to move. The pressure is indicated by the
the effect of pressure. Since these elements are deformed pointer over a dial which can be graduated in a suitable
within the elastic limit only, therefore these gauges are scale.
540 POWER PLANT ENGINEERING
Bourdon
tube
Rack
Pinion
Ra
ck
Pinion
Needle
Corrugated
Pointer diaphragm
5. Generation of a voltage or current through the operate at some predetermined values of current. It can
use of photo-electric effects. also be used to develop voltages across known resistors. It
6. Torque-balance system (electromagnetic). can cause electromagnets to establish forces used for
measuring the force applied which is obtained by pressure
11.3.4.1. Potentiometer devices bellows.
One of the simplest of pressure or voltage transducer uses
a potentiometer. The potentiometer is used to convert a 11.4. THERMOMETERS
pressure signal into an electrical voltage as shown in
Fig. 11.9. 11.4.1. Temperature
Temperature can be defined as a thermal state which
Output
depends upon the internal or molecular energy of the body.
potential
In practice, mean kinetic energy of molecules of a body
changes, thus when body possessing high mean molecular
kinetic energy is brought in contact with a body having
low value, the energy will flow from the higher level to the
Voltmeter lower level. This gives us an idea of the hot and cold bodies
and the heat which is associated with them.
Pivot
of thermometer. The mercury or all be used. The principle on which they work is quite simple.
The fluid is confined in a closed system. In this case the
80
liquid and is used from – 38.9°C the thermometer consists of a bulb which contains bulk of
50
(melting point) to about 600°C. The the fluid. The bulb is placed in the region whose temperature
thermometers employed in the is required. A capillary tube connects the bulb to a Bourdon
40
laboratory have the scale engraved tube, which is graduated with a temperature scale.
30
directly on the glass stem. A usual Pressure thermometers are discussed below :
(i) Vapour pressure thermometer. A schematic
20
the top of the stem to allow room for fluid vapourizes, and increases the vapour pressure. This
90
Bourdon
temperatures above its range. The spring
70
change of pressure is indicated on the Bourdon tube. of liquid filled thermometer. The gases used in the gas
The relation between temperature and vapour pressure thermometers are nitrogen and helium. Both these gases
of a volatile liquid is of the exponential form. Therefore, are chemically inert, have good values for their co-efficient
the scale of a vapour pressure thermometer will not be of expansion and have low specific heats. The construction
linear. of this type of thermometer is more or less the same as
(ii) Liquid-filled thermometer. A liquid-filled mercury-thermometer in which Bourdon spring is used.
thermometer is shown in Fig. 11.12. In this case, the The errors are also compensated likewise. The only
expansion of the liquid causes the pointer to move on the difference in this case is that bulb is made much larger
dial. Therefore liquids having high co-efficient of than used in liquid-filled thermometers. For good
expansion should be used. In practice, many liquids e.g. performance the volume of the bulb should be made at least
mercury, alcohol, toluene, and glycerine have been 8 times than that of the rest of the system.
successfully used. The operating pressure varies from These thermometers are generally used for
about 3 to 100 kgf/cm2. These type of thermometers could pressures below 35 kgf/cm2.
be used for a temperature upto 650°C in which mercury
could be used as the liquid. 11.4.2.3. Thermocouple thermometers
For higher range of temperature i.e., above 650°C, filled
Pressure thermometers are unsuitable. For higher range of
measuring device temperature, thermocouples and pyrometers are used.
In its simplest form a thermocouple consists of two
dissimilar metals or alloys which develop e.m.f. when the
reference and measuring junctions are at different
Capillary
temperatures. The reference junction or cold junction is
tubing
usually maintained at some constant temperature, such
Liquid as 0°C and the device used for measuring the temperatures.
Fig. 11.13 shows a simple circuit of a thermocouple and
the temperature measuring device. In many industrial
installations the instruments are equipped with automatic
Bulb compensating devices for tempearture changes of the
reference junction, thus eliminating the necessity of
maintaining this junction at constant temperature.
11.4.2.4. Resistance thermometers frame. The delicate coil is then enclosed in a porcelain or
The fact that the electrical resistance of the metals quartz tube. The change of resistance of this unit can be
increases with temperature is made use of in resistance measured by instruments such as wheatstone bridge,
thermometers which are purely electrical in nature. A potentiometer or galvanometer.
resistance thermometer is used for precision measurements Advantages
below 150°C.
The resistance thermometers possess the following
A simple resistance thermometer consists of a advantages over other devices :
resistance element or bulb, electrical loads, and a resistance
1. A resistance thermometer is very accurate for
measuring or recording instrument. The resistance element
low ranges below 150°C.
(temperature sensitive element) is usually supplied by the
manufacturers with its protecting tube and is ready for 2. It requires no reference junction like
electrical connections. The resistance of the metal used as thermocouples and as such is more effective at
resistance element should be reproducible at any given room temperature.
temperature. The resistance is reproducible if the 3. The distance between the resistance element and
composition or physical properties of the metal do not change the recording element can be made much larger
with temperature. For this purpose platinum is preferred. than is possible with pressure thermometers.
A platinum resistance thermometer can measure 4. It resists corrosion and is physically stable.
temperatures to within 0.01°C. However, because of high
Disadvantages
cost of platinum, nickel and copper are used as resistance
elements for industrial purposes for low temperatures. The 1. The resistance thermometers cost more.
fine resistance wire is wound in a spiral form on a mica 2. They suffer from time lag.
PLANT INSTRUMENTATION 545
Thermocouple Image
R Correct
B
Ammeter
1. The temperature of moving objects can be Table 11.2 gives the summary of temperature range
measured. of different instruments.
2. A higher temperature measurement is possible
than that possible by thermocouples etc. 11.5. LIQUID LEVEL GAUGES
3. The average temperatures of the extended surface In a boiler house one of the important readings is the level
can be measured. of water. The water level should be measured in all boilers
4. The temperatures of the objects which are not all the times. Out of several methods available for
determining the levels, some of them are as follows :
easily accessible can be measured.
1. By sight glass
11.4.2.6. Optical pyrometer 2. Cable and float
An optical pyrometer works on the principle that matters 3. By hydrostatic pressure
glow above 480°C and the colour of visible radiation is 4. By float and hydraulic pressure
proportional to the temperature of the glowing matter. 5. By strain gauges
The amount of light radiated from the glowing matter 6. By radiation absorption gauges.
(solid or liquid) is measured and employed to determine
the temperature. 11.5.1. Gauge Glass
Fig. 11.15 shows a disappearing filament pyrometer. In case of high pressure boilers (350 kgf/cm2, 650°C) special
attention is given to the sufficient strength of the glass.
Operation
One of the drawbacks of the gauge glass is when liquid
— The optical pyrometer is sighted at the hot body stains or discolours the tube to such a degree that the level
and focused. cannot be read and the tube cleaning is required. A special
— In the beginning filament will appear dark as device uses a special guide float carrying a permanent
compared to the background which is bright magnet within a stainless-steel chamber and a scale
(being hot). consisting of a series of magnetised elements mounted on
546 POWER PLANT ENGINEERING
As high As high
desired desired
Optical
760°C
meters
Pyro-
as
–
–
painted and the other silver. The liquid level in
modern thermal power station is indicated on a liquid
meters
About
temp.
Radia-
room
Pyro-
tion
as
level recorder which is generally located at a distance
–
–
from the actual boiler tank.
– 140°C – 184°C – 184°C
316°C
Resistance thermometers
ments.
Table 11.2. Summary of Temperature Range of Different Instruments
120°C
Alarm or
control relay
Anode
Copper- Chromel Platinum
Rhodium
1540°C
Grid
Constan- Chromel Expen-
0°C
Triode tube
sive.
Cathode – +
is 2% Al,
60% Cu, Cr, 80%
– 184°C
98% Ni.
1260°C
Alumel
is 20%
Ni.
+ –
Thermocouples
Probe
G
– 250°C
40% Ni.
350°C
tan is
tan
Industry.
Constan-
– 196°C
used in
Easier to Normal- To be Requires Widely
760°C
Iron-
Liquid
tan
level
– 269°C
540°C
scale.
filled
G¢
tempera-
Vapour Liquid-
– 87°C
in am-
650°C
tures.
Pressure filled
bient
316°C
mometer mometer
mome-
accurate; uid-in-
– 75°C
540°C
Ther-
glass
ther-
ters.
read
broken.
– 39°C
Easily
600°C
price;
Low
Glass
Ther-
ture limit
tempera-
Remarks
tempera-
Type of
Instru-
High
Low
11.6. FLOW METERS ion than pure water will be acidic and degree is governed
by the difference. Other solution producing less hydrogen
The various flow meters employed for measuring flow rates ions than pure water will be alkaline and the degree is
are as follows : also governed by the difference.
1. Steam flow meters—measure steam output of The pH value of all solutions is accommodated
boilers and turbine supply etc. between 0 and 14. The selection of the numbers 0 to 14 is
2. Air flow meters—measure air flow rate in gas not arbitrary but is actually the number of decimal places
turbines etc. required to record the measure of weight of H2 ions per
3. Water flow meters—measure feed water litre of solution having ascending or descending values of
condensate and pump discharge. acid and alkaline. Thus a solution having no decimal place
Rate of flow of water is generally measured by a is represented by 1 or 1 gram of H2 ions per litre. This
venturimeter Fig. 11.17. It consists of three parts : solution would be highly acidic as compared with water.
Such value on pH scale is represented as zero. Acid or
(i) A short converging part
alkaline nature of a solution depends on whether hydrogen
(ii) Throat or hydroxyl (OH) ions predominate. The pure water
(iii) Diverging part. contains H+ and OH– ions. The extent to which this
dissociation is present in a given sample depends upon
temperature. At 20°C, the concentration of these ions is of
h the order of 10–14. Due to this, pH scale has been spread
to 14.
2 Earlier pH number was measured by observing the
d1 1 d2 change in colour or turbidity by comparing it with a
standard sample. The mostly used now a days is to find
Inlet Throat pH numbers by measuring the potential created by a special
battery. The hydrogen ion reacts with a special glass
Fig. 11.17. Venturimeter. electrode and produces a potential whose value can be
A venturimeter works on Bernoulli’s principle. As measured. It has been seen that the current flow in the
the water flows from end 1 to end 2 a difference between ionisation cell is extremely small, being of the order of a
water levels (h) in the piezometers is obtained. billionth of an ampere. This can be detected by passing it
The rate of water discharge (Q) is given by through a resistor of extremely high value. The potential
developed under these conditions is then read by noting
a1a2 the response of a meter in the plate circuit of a special
Q = Cd × 2 gh
a12 a22 vacuum tube. The circuit has two cells, one the active cell
2 which produces an e.m.f. proportional to the hydrogen ion
where a1 = Area at section 1 = d , concentration. The second cell is used for reference purposes.
4 1
This reference cell is made with calomel, which is a
2
a2 = Area at section 2 = d , compound of mercury or with silver-silver chloride. One of
4 2 the methods of measuring hydrogen ion concentrations is
h = Difference in water levels in the piezometers, based on the fact that when a piece of metal is placed in an
and ionic solution of the same metal, there will be a potential
Cd = Co-efficient of discharge. developed between the metal and the solution. The value
of this e.m.f. is proportional to the concentration of ions.
11.7. pH MEASURING INSTRUMENTS
11.8. GAS ANALYSERS
The pH is a number denoting the degree of acidity or
alkalinity of a substance. It does not indicate the quantity The gas analysis is carried out to determine the
of acid or alkaline in a solution as found by titration method. concentration of one or more components of a gas mixture.
It is derived by measuring the amount of hydrogen ion (H+) In steam power plants, the object of gas analysis is to keep
in grams per litre of solution. For example, pure water the concentration of carbon dioxide (CO2) and oxygen (O2)
ionizes to produce 10–7 grams of H2 ions per litre. Therefore, as minimum as possible therefore, constant recording of
any substance producing 10–7 grams of hydrogen ions per these components in exhaust gases is necessary. The
litre is considered to be a neutral solution. The greater the recording of these components helps to improve the
amount of hydrogen ions present in solution its acid efficiency of steam generation. The common types of
reaction becomes stronger. Therefore, pure water being analysers used for the measurement of CO2 and O2 are
neutral solution, any solution producing more hydrogen described next page.
548 POWER PLANT ENGINEERING
Measurement of Carbon dioxide (CO2) : This type of instrument gives accurate values if the
Since the gases differ in their ability to conduct the proportion of H2 present is small and constant.
heat, therefore, the proportion of various constituents of
Measurement of Oxygen (O2)
flue gases can be determined by measuring their thermal
conductivity. If the thermal conductivity of air is considered Although there are other methods to measure O2,
as unity at 0°C, the thermal conductivity of CO2 = 0.585 ; we shall discuss have only “paramagnetic oxygen analyser”.
H2 = 7.35, N2 = 1.015 ; O2 = 1.007 respectively. This analyser works on the principle of paramagnetic
Fig. 11.18 shows the commonly used method for properties of O2. Oxygen is the only paramagnetic
measuring CO2 content is flue gases. component in the flue gases. It has very high magnetic
permanence compared with other gases. The magnetic
— It consists of hot wire thermal conductivity gas
analysis cell which comprises of two chambers, permanence of paramagnetic gases decreases with an
each containing a wire filament as shown in increase in temperature. The gas molecules near the heated
Fig. 11.18. body in the magnetic field lose part of their magnetic
properties and are pushed out of the magnetic field by cooler
— The gas is passed through one chamber whose
conductivity is to be measured and other molecules. The temperature of the cooler molecules entered
chamber is filled with a reference gas like air in the magnetic field where heated body is situated is
and scaled. increased and in turn they are also pushed out of magnetic
field by other molecules. In this way, a convection flow
Measuring Measuring Reference known as ‘Magnetic Wind’ is created which cools the heated
filament chamber filament body. The magnetic wind increases with an increase in O2
content in the flue gases and cooling of the heated body is
intensified. The temperature change of heated body alters
its electric resistance which indicates the concentration of
Gas in Gas out
O2 in the gas mixture. Therefore, the O2 content can be
measured by measuring an electric resistance of the heated
body which can be one of the arms of Wheatstone bridge.
Fig. 11.19 shows the electric circuit used for O2
Amplifier
Gas out
Slider
— The gas is aspirated into the measuring cell These tubes are wetted by the absorbing agents and are
through an annulus with an horizontal by-pass exposed to the gas under analysis. The measuring burette
tube (as shown in Fig. 11.19). This by-pass tube is surrounded by a water jacket to prevent changes in
has two identical adjacent platinum windings temperature and density of the gas. Pipette 1 contains
on the outside which are connected into a caustic soda (KOH) which absorbs carbon dioxide, pipette
Wheatstone bridge circuit and become heated 2 is filled with an alkaline solution of pyrogallic acid which
by the application of voltage across the bridge. absorbs oxygen content of the gas while pipettes 3 and 4
One of these windings is cut by an intense are provided with an acid solution of cuprous chloride to
magnetic field produced by a large permanent absorb carbon monoxide. Further-more the apparatus has
magnet. a levelling bottle and a three way cocks to connect the
— When the sample of flue gas enters into the cell, apparatus either to gases or to atmosphere.
O2 is drawn into the bypass by virtue of its
paramagnetic properties. It is heated by the
winding which reduces the magnetic
susceptibility of the gas. Cool O2 from the gas S S1 S2 S3 S4
of higher susceptibility is drawn in the tube
Burette
displacing the hot gas which passes along the
Cuprous chloride
Cuprous chloride
tube back into the annulus. This ‘magnetic wind’
Pyrogallic acid
causes differential cooling of the two windings
KOH
Water
and by the change of resistance with temperature
unbalances the bridge. The resulting unbalanced
e.m.f. is measured by a standard potentiometer
Flue sample
Wet bulb
Capillary
temperature of the remaining water is lowered due to heat Dry bulb
sleeve
required by the evaporation process. The amount of
evaporation and consequent lowering of the temperature Wet bulb
depends upon the capability of the air to absorb the Water
moisture. Thus if the relative humidity is lower, air has level
small moisture and can therefore absorb more. Hence the
evaporation is faster and the temperature of the remaining Water Water
in out
water will be lower.
In the sling psychrometer, a handle is provided Fig. 11.23. Commercial type psychrometer.
whereby the thermometer may be whirled, so that the bulbs
continuously come in contact with fresh air. If this is not The two thermometers are connected to a recorder
through capillary tubes. In order to avoid errors arising on
done the stagnant mositure-laden air will engulf the
account of contamination of the wick the bulb may be
thermometer thereby causing errors.
enclosed in a porcelain sleeve and water is pumped into
The dry bulb thermometer is unaffected by the
the annular space at a constant rate. These instruments
moving air and registers the ambient temperature. The are not suited for instantaneous monitoring and control of
wet bulb thermometer shows a lower temperature due to humidity.
evaporation. Since the cooling effect is a function of the
A variation in the indication and recording
relative humidity of air, the relative humidity may be
arrangement is also possible if the filled in thermometers
determined by comparing the readings of the two
are replaced by resistance thermometers or thermocouples.
thermometers. Relative humidity can directly be read off
from psychrometric charts. Dew Point Measurements
Psychrometric charts graphically describe the The dew point is a discrete temperature. Specially,
relationship between the properties of moist air i.e., the it is that temperature at which liquid water and water
dry bulb, the wet bulb and dew point temperatures of the vapour, or ice and water vapour are in equilibrium. At this
temperature only one value of saturation vapour pressure
mixture and humidity.
(of water vapour) exists. Hence, the absolute humidity can
2. Commercial type psychrometer : be determined from this temperature if the pressure is
A commercial type psychrometer is shown in known.
Fig. 11.23. The filled system thermometer bulbs are placed Two methods used for measuring dew point
adjacent to each other and air is blown across the assembly temperatures are given below :
or they may be placed where there is strong current of air First Method
(nearly 5 m/s). One of the bulbs is coated with a knitted or Refer to Fig. 11.24. This method uses the resistive
woven cotton which is suspended into a water reservoir hygrometer described previously. The arrangement consists
whose level is controlled so that the required conditions of a thin metal tube covered with a glass cloth saturated
are satisfied. The temperatures are recorded by suitable with lithium chloride. A double winding of silver is made
recorders. over the glass cloth.
552 POWER PLANT ENGINEERING
Light
Metal tube source
A.C. Supply
To recorder Thermocouple
Gas
tor
era
frig
Re
Photo tube
Saturated salt Mirror
Heater
Double winding
Thermometer
bulb
Fig. 11.26. Dionic water purity meter. 11.12.1.1. Tank or bucket calorimeter
— Conductivity is measured of two water columns The dryness fraction of steam can be found with the help
in between rings and gunmetal collars. The of tank calorimeter as follows :
conductivity per cm3 indicated is the reciprocal A known mass of steam is passed through a known
of the resistance measured. The standard of mass of water and steam is completely condensed. The heat
reference is the resistance of one megaohm lost by steam is equated to heat gained by the water.
between opposite faces of a cm3 of solution. Fig. 11.27 shows the arrangement of this calorimeter.
— Dionic readings of condensate and feed water The steam is passed through the sampling tube into
at various points of flow are brought to one the bucket calorimeter containing a known mass of water.
Bucket
calorimeter
Mixing
box Insulation
Water
Weighing
machine
Temperature
Let ps = Gauge pressure of steam (bar), Pressure
pa = Atmospheric pressure (bar), High pressure p2
steam
ts = Saturation temperature of steam known
from steam table at pressure (ps + pa),
hfg = Latent heat of steam,
x = Dryness fraction of steam,
cpw = Specific heat of water,
cpc = Specific heat of calorimeter,
mc = Mass of calorimeter, kg,
mcw = Mass of calorimeter and water, kg,
mw = (mcw – mc) Exhaust
= Mass of water in calorimeter, kg, Fig. 11.28. Throttling calorimeter.
mcws = Mass of calorimeter, water and The steam to be sampled is taken from the pipe by
condensed steam, kg, means of suitably positioned and dimensioned sampling
ms = (mcws – mcw) = Mass of steam tube. It passes into an insulated container and is throttled
condensed in calorimeter, kg, through an orifice to atmospheric pressure. Here the
temperature is taken and the steam ideally should have
tcw = Temperature of water and calorimeter
about 5.5 K of superheat.
before mixing the steam, °C, and
The throttling process is shown on h-s diagram in
tcws = Temperature of water and calorimeter Fig. 11.29 by the line 1-2. If steam initially wet is throttled
after mixing the steam, °C. through a sufficiently large pressure drop, then the steam
Neglecting the losses and assuming that the heat at state 2 will become superheated. State 2 can then be
lost by steam is gained by water and calorimeter, we have defined by the measured pressure and temperature. The
(mcws – mcw) [xhfg + cpw (ts – tcws)] enthalpy, h2 can then be found and hence
= (mcw – mc) cpw (tcws – tcw) + mc cpc (tcws – tcw) h2 = h1 = ( hf x1hfg ) at p1
1 1
p1 Pressure
T3
Steam p1, x1 p2, x2, h2
main Outlet
x1 p3, h3
Separating Throttle valve
calorimeter
Cooling water
inlet
mw
ms
Dryness fraction at 2 is x2, therefore, the mass of because its shape resembles that of a bomb. Fig. 11.31
dry steam leaving the separating calorimeter is equal to shows the schematic sketch of a bomb calorimeter.
x2ms and this must be the mass of dry vapour in the sample The calorimeter is made of austenitic steel which
drawn from the main at state 1.
provides considerable resistance to corrosion and enables
Hence fraction in main,
it to withstand high pressure. In the calorimeter is a strong
Mass of dry vapour x2ms cylindrical bomb in which combustion occurs. The bomb
x1 = .
Total mass mw ms has two valves at the top. One supplies oxygen to the bomb
The dryness fraction, x2, can be determined as and other releases the exhaust gases. A crucible in which
follows : a weighed quantity of fuel sample is burnt is arranged
*h3 = h2 = hf2 + x2 hfg2 at p2 between the two electrodes as shown in the Fig. 11.31. The
calorimeter is fitted with water jacket which surrounds
[*h3 = hf3 hfg3 + cp(Tsup – Ts3 ) a pressure p3]
the bomb. To reduce the losses due to radiation, calorimeter
h3 hf2 is further provided with a jacket of water and air. A stirrer
or, x2 = for keeping the temperature of water uniform and a
hfg2
thermometer to measure the temperature up to an accuracy
The values hf and hfg are read from tables at
2 2 of 0.001°C are fitted through the lid of the calorimeter.
pressure p2. The pressure in the separator is small so that
p1 is approximately equal p2. Procedure. To start with, about 1 gm of fuel sample
is accurately weighed into the crucible and a fuse wire
11.12.2. Fuel Calorimeters (whose weight is known) is stretched between the
electrodes. It should be ensured that wire is in close contact
11.12.2.1. Bomb calorimeter
with the fuel. To absorb the combustion products of sulphur
The calorific value of solid and liquid fuels is determined and nitrogen 2 ml of water is poured in the bomb. Bomb is
in the laboratory by ‘Bomb Calorimeter’. It is so named then supplied with pure oxygen through the valve to an
556 POWER PLANT ENGINEERING
amount of 25 atmosphere. The bomb is then placed in the Note 1. Corrections pertain to the heat of oxidation of
weighed quantity of water, in the calorimeter. The stirring fuse wire, heat liberated as a result of formation of
is started after making necessary electrical connections, sulphuric and nitric acids in the bomb itself.
and when the thermometer indicates a steady temperature 2. It should be noted that bomb calorimeter measures the
fuel is fired and temperature readings are recorded after higher or gross calorific value because the fuel sample is
1/2 minute intervals until maximum temperature is burnt at a constant volume in the bomb. Further the bomb
attained. The bomb is then removed ; the pressure slowly calorimeter will measure the H.C.V. directly if the bomb
released through the exhaust valve and the contents of the contains adequate amount of water before firing to saturate
bomb are carefully weighed for further analysis. the oxygen. Any water formed from combustion of hydrogen
will, therefore, be condensed.
Thermometer The procedure of determining calorific values of
liquid fuels is similar to that described above. However, if
the liquid fuel sample is volatile, it is weighed in a glass
Oxygen bulb and broken in a tray just before the bomb is closed. In
valve
Copper this way the loss of volatile constituents of fuels during
calorimeter weighing operation is prevented.
Rheostat
Fig. 11.31. Bomb calorimeter.
The heat released by the fuel on combustion is
absorbed by the surrounding water and the calorimeter.
Over flow
Cold water
Gases
calorimeter
t2 = final temperature of water and Exhaust
calorimeter (Gases) to
Gas meter
tc = radiation corrections. atmosphere
Heat released by the fuel sample = wf × C.
Heat received by water and calorimeter Pressure Condensate
= (w + we) [(t2 – t1) + tc] regulator
Heat lost = heat gained
Fig. 11.32. Junker’s gas calorimeter.
wf × C = (w + we)[(t2 – t1) + tc]
Procedure. A metered quantity of gas whose
(w we )(t2 t1) tc calorific value is to be determined is supplied to the gas
C= kJ/kg ...(11.3)
wf burner via a gas meter which records its volume and a gas
PLANT INSTRUMENTATION 557
pressure regulator which measures the pressure of the gas ingoing and outgoing water are indicated by the
by means of a manometer. When the gas burns the hot thermometers. From the above data the calorific value of
product of combustion travels upwards in the chamber and the gas can be calculated.
then downwards through the flues and finally escape to
Note 1. The volume of gas used during the experiment
the atmosphere through the outlet. The temperature of the
should be converted to volume at S.T.P.
escaping gas is recorded by the thermometer fitted at the
(standard temperature and pressure) i.e., 15°C, 760 mm
exit and this temperature should be as close to room
respectively.
temperature as possible so that entire heat of combustion
is absorbed by water. The cold water enters the calorimeter 2. The gross calorific value is obtained by dividing the heat
given out by corrected volume of gas. The net or lower
near the bottom and leaves near the top. Water which is
calorific value of the gas is obtained by subtracting from
formed by condensation of steam is collected in a pot.
total heat the heat associated with condensed water (which
The quantity of gas used during the experiment is is obtained by multiplying the weighed condensate by
accurately measured by the meter and temperature of latent heat of vapourisation of water).
HIGHLIGHTS
1. Commonly used instruments in a power plant are : 7. An optical pyrometer works on the principle that matters
(i) Pressure gauges, (ii) Thermometers, (iii) Liquid level glow above 480°C and the colour of visible radiation is
gauges, (iv) Flow meters, (v) pH measuring instruments, proportional to the temperature of the glowing matter.
(vi) Gas analysers, (vii) Humidity measuring instruments, 8. The hygrometer is an instrument which measures
(viii) Impurity measuring instruments, (ix) Speed humidity directly.
measuring instruments, (x) Steam calorimeters and fuel 9. The psychrometer is a humidity measuring instrument
calorimeters, (xi) Gong alarms. which utilizes one wet bulb thermometer and other dry
2. Low pressures are generally determined by manometers bulb thermometer.
which employ liquid columns. 10. Dionic water purity meter works on the principle that the
3. A Bourbon type tube pressure gauge is used for measuring electrical conductivity of an electrolyte dissolved in water
high as well as low pressures. depends on the amount of salt in solution i.e., the extent
4. A transducer is device for converting a signal of one sort of impurity.
into the other type. 11. The dryness fraction of steam can be measured by using
5. Temperature can be defined as a thermal state which the following calorimeters :
depends upon the internal or molecular energy of the body. (i) Tank or bucket calorimeter
6. A resistance thermometer is used for precision (ii) Throttling calorimeter
measurements below 150°C. (iii) Separating and throttling calorimeter.
THEORETICAL QUESTIONS
1. List the functions which the various types of instruments (ii) Liquid filled thermometers
in a power plant have to perform. (iii) Gas-filled thermometers.
2. How are instruments classified ? 12. Write a short note on resistance thermometers.
3. What is the difference between gauge pressure and 13. Explain with a help of a neat sketch the construction and
absolute pressure ? working of a radiation pyrometer.
4. Enumerate various types of pressure measurement 14. What are the advantages of pyrometers ?
devices. 15. State the principle on which an optical pyrometer works.
5. Explain briefly the following : 16. Describe with the help of a neat sketch an optical
(i) U-tube manometer (ii) Micro-manometer. pyrometer.
6. Describe briefly the following pressure gauges : 17. Explain briefly the following liquid level gauges :
(i) Bourdon tube pressure gauge (i) Gauge glass (ii) Electrical level gauges.
(ii) Diaphragm gauge. 18. Write a short note on ‘Flow meters’.
7. Explain briefly the following : 19. Explain the procedure for measuring CO2 content in the
(i) Electrical transducers gases.
(ii) Electromagnetic transducers. 20. What is humidity ? How can it be measured ?
8. How is temperature defined ? 21. Give the description of resistive hygrometer.
9. How are temperature measurements made ? 22. How can the dryness fraction of steam determined by the
10. How are thermometers classified ? following ?
11. Explain briefly the following : (i) Tank or bucket calorimeter
(i) Bimetallic thermometers (ii) Separating and throttling calorimeter.
Major Electrical Equipment
in Power Plants 12
12.1. Introduction. 12.2. Generating equipment—Classification—Two-wire direct current generators—Alternator current generators.
12.3. Transformers—General aspects—Basic definitions—Working principle of a transformer—Transformer ratings—Kinds of
transformers—Transformer construction—Transformer windings, terminals, tappings and bushings—Transformer cooling—Three
phase transformer—Instrument transformers—Constant current transformers. 12.4. Switchgear—Functions of a switchgear—
Switches—Fuses—Circuit breakers—Types of switchgear. 12.5. Protection of electrical systems—General aspects— Different
types of relays—Alternator protection—Transformer protection—Bus protection—Protection of transmission lines. 12.6. Short-circuits
in electrical installations and limiting methods. 12.7. Control room. 12.8. Earthing of a power system. 12.9. Electrical equipment-
layout. 12.10. Voltage regulation. 12.11. Transmission of electric power—Systems of transmission—Line supports—Conductor
material—Line insulators—Distribution systems—Underground cables. 12.12. Substations—Classification of substations. 12.13. Indian
Electricity Act—Highlights—Theoretical Questions—Competitive Examinations Questions.
Generating equipment
12.1. INTRODUC TION
In different types of power plants such as thermal power
plant, hydro-power plant, nuclear power plant etc. the Direct current Alternating current
electricity is generated. A number of electrical equipments
which are available in a power plant are listed below :
1. Generators 2. Excitors (i) Two wire generator (i) Synchronous generator
3. Transformers 4. Reactors (ii) Three wire generator (ii) Induction generator
5. Circuit breakers 6. Switchgear and
(iii) Major generator set (iii) Frequency-changes set
protective equipment
7. Control board 8. Busbars (iv) Rotary converter (iv) Phase converter.
equipment (v) Mercury arc rectifier.
9. Standby generators etc.
12.2.2. Two-Wire Direct Current Generators
12.2. GENERATING EQUIPMENT
By two-wire generators are meant such generators as have
12.2.1. Classification only two line terminals, one known as the positive terminal
A broad classification of generating equipment may include and the other as the negative terminal. Direct current
the following types of machines : generators may be further classified according to :
558
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 559
Shunt
Short shunt
Self-excited Series
Long shunt
Compound
1. Method of excitation Flat compound
Separately Over compound
excited Differentially
compound
Bipolar
Homopolar
Multiple or lap
Engine type
Water turbine
Railway
Booster
Exciter
Balancer
Non-commutating-pole machines
Commutating-pole machines
Diverter-pole machines
p 8
in flux linkage occurs at a slower rate than a
4 9 position 3 respectively.
N
3 — When the conductor lm reaches 180°, position
S
ion 10 m 6, the induced e.m.f. is again zero, since no
at
2 rot 11 change in flux linkages occurs when a conductor
of l
A xis 1 is moving parallel to a magnetic field.
— In positions 7 and 8 corresponding to 210° and
(a) Instantaneous positions of 240° respectively, the e.m.f. in conductor lm is
rotation at constant speed.
reversed since conductor lm is now moving
downward in the same uniform magnetic field.
e
+ The e.m.f. induced increases to a negative
maximum at 270°, position 9, and finally
180°
210°
240°
270°
300°
330°
360°
1 2 3 4 5
0 6 7 8 9 10 11
0 decreases through positions 10 and 11
30°
60°
90°
120°
150°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
360°
the alternating voltage (A.C.) to unidirectional current
(D.C.), it is necessary to employ a mechanical switching
device which is actuated by the mechanical rotation of the (b)
dynamo/generator shaft, called a ‘commutator’ (see Fig. 12.3. Bipolar generator with two segment commutator.
Fig. 12.3).
— The simple split-ring commutator shown In effect, therefore, the action of the commutator is
consists of two segments (A and B), secured to to reverse connections to the external circuit simultaneously
and insulated from the armature shaft and from and at the same instant the direction of e.m.f. reverses in
each other as well. Each conducting commutator each of the coil sides. Each brush, positive or negative
segment is connected, respectively, to a coil side. respectively, is always maintained, therefore, at the same
Since both coil side and commutator segment polarity. Fig. 12.3 (b) shows the e.m.f. (and current) wave
are fastened mechanically to the same shaft, the form produced as a result of the above process for one full
action of the mechanical rotation is to reverse cycle (or 360°) of rotation.
the armature coil and connections to the — The pulsating unidirectional current which has
stationary external circuit at the same instant a zero value twice each cycle as shown in
that the induced e.m.f. reverses in the armature Fig. 12.3 (b), is hardly suitable for commercial
coil side (i.e., when the coil side moves under an D.C. use. The output e.m.f. may be made less
opposite pole). Fixed brushes are arranged to pulsating by using a large number of coils and
contact the commutator segments, as shown in commutator segments (Fig. 12.4).
Fig. 12.3.
— As shown in Figs. 12.2 and 12.3, the e.m.f. induced
in coil-side lm causes a positive polarity for the
first 180° of rotation (positions 0 through 6) and a
negative polarity for the remaining 180° (positions
6 through 0). But, in Fig. 12.3, coil side lm is
Fig. 12.4. The output e.m.f. with a large number of coils
connected to commutator segment A and the coil and commutator segments.
side np is connected to commutator segment B.
For the first 180° of rotation, therefore, the positive — It may be noted that a single turn armature coil
e.m.f. produced by the coil-side lm is connected to generates voltage which is quite small in
the stationary positive brush. For the second 180° magnitude. Therefore, the coils employed in
of rotation, the negative e.m.f. produced by coil commercial generators consist of several turns
side lm is connected to the secondary negative in series thereby increasing the magnitude of
brush. The same effect occurs in reverse order for generated e.m.f. in direct proportion to the
coil-side np. number of the turns in the coil.
562 POWER PLANT ENGINEERING
12.2.2.3. Construction of D.C. machines flux, commutating poles interposed between the
A D.C. machine consists of two main parts : main poles and designed to ensure sparkless
operation of the brushes at the commutator (in
(i) Stationary Part. It is designed mainly for
very small machines with a lack of space
producing a magnetic flux.
commutating poles are not used) ; and a frame/
(ii) Rotating Part. It is called the armature, where yoke.
mechanical energy is converted into electrical (electrical
— The armature is a cylindrical body rotating in
generator), or conversely, electrical energy into mechanical
the space between the poles and comprising a
(electric motor).
slotted armature core, a winding inserted in the
The stationary and rotating parts are separated armature core slots, a commutator and brush
from each other by an air-gap. gear.
— The stationary part of a D.C. machine consists Fig. 12.5 shows generator or motor magnetic
of main poles, designed to create the magnetic structure.
Main
Typical line of
frame
magnetic flux
Field
pole Typical slot
N to allow for
re
atu c winding coil
Arm gnetire
maructu space needs
st (one of many)
aft
Sh
S Field
pole
Air gap between
faces of pole and
armature surface
Description of Parts of D.C. Machines : is saturated by a flux density of about 0.8 Wb/m2
Frame : while saturation with cast steel is at about
1.5 Wb/m2. Thus the cross-section of a cast iron
Fig. 12.6 shows the sectional view of four pole D.C. frame is about twice that of a cast steel frame
machine. for the same value of magnetic flux. Hence, if it
— The frame is the stationary part of a machine to is necessary to reduce the weight of machine,
which are fixed the main and commutating poles cast steel is used. Another disadvantage with
and by means of which the machine is bolted to the use of cast iron is that its mechanical and
its bed plate. magnetic properties are uncertain due to the
presence of blow holes in the casting. Lately,
— The ring-shaped portion which serves as the path rolled steel yokes have been developed with the
for the main and commutating pole fluxes is improvements in the welding techniques. The
called the ‘yoke’. advantages of fabricated yokes are that there are
— Cast iron used to be the material for the frame/ no pattern charges and the magnetic and
yoke in early machines but now it has been mechanical properties of the form are absolutely
replaced by cast steel. This is because cast iron consistent.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 563
Holes for
Fig. 12.6. Sectional view of a four pole D.C. machine. holding bolts
Laminations Laminations
Air holes
Slots
Air holes
Armature
coils
Equilizer
rings
The segments are connected to the winding Fig. 12.16 shows the components of a commutator.
through risers. The risers have air spaces The general appearance of a commutator when completed
between one another so that air is drawn across is as shown in Fig. 12.17 (a). The commutator and armature
the commutator thereby keeping the
assembly is shown in Fig. 12.17 (b).
commutator cool.
Riser or lug
Segment
Riser or
lug Micanite
Micanite separator
vee rings
End clamp
Segment ring
Clamp
Shaft bolt
Insulated
copper
Commutator segments
lugs
End
clamp
Shaft
Spider s
n
Commutator atio
min
La
Spacing
rings Armature Fan
Key rings Key
Key
The three most important characteristics of D.C. the source of exciting current, although any
generators are given below : other constant voltage source could be used.
FE I .
1. No load saturation characteristics GH I JK
0
f
Main
switch
F EI
Interpoles
2. Internal or total characteristics G J .
HI K
a
F VI
Source of
3. External characteristics G J .
exciting current
H IK (Battery)
F E I . It is
Load
1. No load saturation characteristic G
H I JK
Armature
0
f
also a known as magnetic or open circuit characteristic Field
(O.C.C.). It shows the relationship between the no-load regulating
generated e.m.f. in armature, E0 and field or exciting resistance
current If at a given fixed speed. The shaped of the curve is
practically the same for all types of generators whether Fig. 12.19. Connection for a separately excited generator.
they are separately excited or self-excited. It is just the The field circuit is provided with a variable
magnetisation curve for the material of the electromagnets. resistance and would normally contain a field switch and
F EI. an ammeter, these being omitted from the diagram for
2. Internal or total characteristic GH I JK
a
It
simplicity. The armature is connected through 2-pole main
switch to the bus bars, between which the load is connected.
gives the relationship between the e.m.f. E actually
induced in the armature after allowing for the (a) No load saturation characteristic (or O.C.C.)
demagnetising effect of armature reaction and the armature — If the generator is run at constant speed with
current Ia. This characteristic is of interest mainly to the the main switch open, and the terminal voltage
designer. is noted at various values of exciting or field
FG IJ
V current then the O.C.C. shown in Fig. 12.20 can
3. External characteristic
H K
I
:
be plotted. This is also referred to as the
— This characteristic is also referred to as ‘magnetisation curve’ since the same graph
performance characteristic or sometimes shows, to a suitably chosen scale, the amount
voltage-regulating curve. of magnetic flux, there being a constant
— It gives relation between the terminal voltage relationship (depending upon speed of rotation)
V and load current I. between flux and induced voltage.
— The curve lies below the internal characteristics
because it takes into account the voltage drop
over the armature circuit resistance. The values
of V are obtained by substracting IaRa from
corresponding values of E.
— This characteristic is of great importance in
judging the suitability of a generator for a
particular purpose.
EO, V
— It will be noticed that a small voltage is produced (ii) Resistance drop, this being the product of the
when the field current is zero, this being due to armature current and the total armature-circuit resistance,
a small amount of permanent magnetism in the consisting of the armature resistance, interpole resistance
field poles. This is called residual magnetism and brush contact resistance.
and is usually sufficient to produce 2 or 3 per — The ‘internal characteristic’ is obtained by
cent of normal terminal voltage, although in calculating the resistance drop for a few values
some special cases it is purposely increased to of current and adding this to the voltage shown
10 per cent or more. by the external characteristics. The vertical
— The first part of the curve is approximately distance between the internal characteristic and
straight and shows that the flux produced is no load voltage then represents the effect of
proportional to the exciting current ; but after a armature reaction alone.
certain point, saturation of the iron becomes — When the resistance of load is R, then voltage
perceptible as the curve departs from straight across its terminals is V = IR, where I represents
line form. the current, so that if the value of V
(a) Internal and external characteristics corresponding to various values of I are
(or load characteristics) calculated, the values will all lie upon a straight
line such as OL in Fig. 12.21. The load current
— Load characteristics for a separately excited
and terminal voltage corresponding to this
generator are shown in Fig. 12.21. The most
resistance are given by the inter-section of the
important is the ‘external characteristic’ (or total line OL with the external characteristics.
characteristic), which indicates the way in which
the terminal voltage (V) varies as the load Note. The great advantage of separate excitation over all
current is increased from zero to its full load other forms of excitation is that the current is entirely
value, the speed of rotation and exciting current independent of the load current in the armature. It is,
being constant. however, rather inconvenient to have to depend upon a
separate source of supply and, therefore, the method is
Internal used only in special cases, where the generator has to
No load voltage (E0) characteristics operate over a wide range of terminal voltage.
L
Building up the voltage of self-excited shunt
generator :
One of the simplest forms of ‘self-excited’ generator
is the shunt-wound machine, the connection diagram
(without load) of which is shown in Fig. 12.22. The manner
External
characteristics in which a self-excited generator manages to excite its own
field and build a D.C. voltage across its armature is
Volts
Interpoles
O
Load current (I)
V Field
Fig. 12.21. Load characteristics of a Armature winding
separately excited generator.
1
E7 process would take place along field resistance
E6 line Rf , and build-up a somewhat higher value
1
than E8, i.e., the point where Rf intersects the
1
E5 magnetisation curve, E9. Since the curve is
extremely saturated in the vicinity of E9,
E4 reducing the field resistance (to its limiting field
E3 winding resistance) will not increase the voltage
E2 appreciably. Conversely, increasing the field
E1 rheostat resistance and the field circuit
O I1 I2 I3 I4 I5 I6 I7 I8
resistance (to a value having a higher slope than
Rf in the figure) will cause a reduction of the
Field current (Ish or If), amp.
maximum value to which build-up can possibly
Fig. 12.23. Building up the voltage of a shunt generator. occur.
— The field resistance may be increased until the
— Assume that the generator starts from rest, i.e.,
field circuit reaches a critical field resistance.
prime-mover speed is zero. Despite a residual
Field circuit resistance above the critical field
magnetism, the generated e.m.f. E, is zero.
resistance will fail to produce build-up. The
— As the prime mover rotates the generator critical field circuit resistance, Rc, is shown as
armature and the speed approaches rate speed, tangent to the saturation curve passing through
the voltage due to residual magnetism and speed the origin, O, of the axes of the curve of Fig. 3.5.
increases. Thus a field circuit resistance higher than Rc
— At rated speed, the voltage across the armature will produce an armature voltage of E1
due to residual magnetism is small, E1, as shown approximately (and no more).
in the figure. But this voltage is also across the
field circuit whose resistance is Rf. Thus, the Reasons for Failure of Self-Excited Shunt
current which flows in the field circuit I1, is also Generator to Build-up Voltage :
small. The reasons why a self-excited generator may fail
— When I1 flows in the field circuit of the generator to build-up voltage are given below :
of Fig. 12.22, an increases in m.m.f. results (due 1. No residual magnetism. The start of the build-
to IfTf , Tf being field turns, which aids the up process requires some residual magnetism in the
residual magnetism in increasing the induced magnetic circuit of the generator. If there is little or no
voltage to E2 as shown in Fig. 12.23. residual magnetism, because of inactivity or jarring in
— Voltage E2 is now impressed across the field, shipment, no voltage will be generated that can produce
causing a large current I2 to flow in the field field current. To overcome this difficulty, a separate source
circuit. I2Tf is an increased m.m.f., which of direct current is applied to the field for a short period of
produces generated voltage E3. time and then removed. The magnetic field should now be
sufficient to allow the voltage to build-up. The application
— E3 yields I3 in the field circuit, producing E4.
of a separate source of direct current to the field is called
But E4 causes I4 to flow in the field producing
‘flashing the field’.
E5 ; and so on, up to E8, the maximum value.
2. Field connection reversed. The voltage
— The process continues until that point where the
generated due to residual magnetism is applied to the field.
field resistance line crosses the magnetisation
Current should flow in the field coils in such a direction as
curve in Fig. 12.23. Here the process stops. The
to produce lines of flux in the same direction as the residual
induced voltage produced, when impressed
flux. If the field connections are reversed, the lines of flux
across the field circuit, produces a current flow
produced by the current flow will oppose the residual flux
that in turn produces an induced voltage of the
so that the generated voltage will decrease rather than
same magnitude, E8, as shown in the figure.
increase when the field circuit is closed. In this instance it
Critical resistance : is necessary to reverse the field connections with respect to
— In the above description a particular value of the armature.
field resistance Rf was used for building up of 3. Field circuit resistance too high. A field circuit
self-excited shunt generator. If the field resistance greater than critical value will prevent an
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 571
appreciable build-up. At no load, resistance greater than becomes smaller and therefore field current will be less. A
the critical may be caused by the following : reduction in the magnitude of field current also reduces
— Open field circuit connection. The effects of the flux from the field poles, which in turn reduces the
an open circuit are apparent. The field circuit generated voltage and also the terminal voltage.
resistance is much greater than the critical External characteristic :
value; hence generator will not build-up. — See Figs. 12.24 and 12.25. The effect of the
— Dirty commutator. A dirty commutator does preceding three factors is shown in Fig. 12.25,
not permit good contact between the brushes which shows external (load-voltage)
and the commutator. This poor contact shows characteristic of a shunt generator.
up as a high resistance to the flow of current in
the field circuit and produces the same effect as Ish or If
a high field circuit resistance.
I
Shunt generator characteristics :
In a shunt generator the field circuit is connected Ia
directly across the armature. Appliances, motors, light
bulbs, and other electrical devices connected in parallel Shunt
across the generator terminals represent a load on the field
V Armature
generator. As more devices are connected in parallel, the winding
load on the generator increases; that is, the generator (Rsh or Rf)
current increases. Because the generator current increases, Load
the terminal voltage of the generator decreases. There are
three factors that cause this decrease in voltage :
(i) Armature-circuit resistance (Ra)
(ii) Armature reaction Fig. 12.24. Shunt generator under load.
(iii) Reduction in field current. — As shown in the circuit of Fig. 12.24, the
(i) Armature-circuit resistance. The armature readings of the voltage across the armature (and
circuit of a generator, like every electrical circuit, contains load), V are plotted as a function of load current,
resistance. This resistance includes the resistance of : I. The voltage, V, is the same as Eg at no-load
(i) the copper conductors of the armature winding, (ii) the (neglecting the IaRa and armature reaction drop
commutator, (iii) contact resistance between brushes and produced by the field current). The effects of
commutator, and (iv) the brushes themselves. When no armature reaction, armature circuit voltage
current flows through the armature, there is no IR drop in drop, and decrease in field current are all shown
the armature and the voltage at the terminals is the same with progressive increase in load. Note that both
as the generated voltage. However, when there is current the armature reaction and the IaRa drop are
in the armature circuit, a voltage drop exists due to the shown as dashed straight lines, representing
armature resistance, and the terminal voltage is less than theoretically linear voltage directly proportional
the generated voltage. The terminal voltage may be to the increase in load current. The drop owing
calculated from the following reaction : to decreased field current is a curved line, since
V = Eg – IaRa it depends on the degree of saturation existing
in the field at the value of load.
where V = voltage at terminals of generator
— Generally, the external load-voltage characte-
Eg = generated or induced voltage
ristic decreases with application of load only to
Ia = total armature current a small extent up to its rated load (current) value.
Ra = armature-circuit resistance. Thus, the shunt generator is considered as
(ii) Armature reaction. When current flows in the having a fairly constant output voltage with
armature conductors a flux surrounds these conductors. application of load, and in practice, is rarely
The direction of this armature flux is such that it reduces operated beyond the rated load current value
the flux from the field poles, resulting in both a reduced continuously for any appreciable time.
generated voltage and terminal voltage. — As shown in Fig. 12.25 further application of
(iii) Reduction in the field current. The field load causes the generator to reach a breakdown
circuit is connected across the terminals of the generators. point beyond which further load causes it to
When the terminal voltage of the generator becomes ‘unbuild’ as it operates on the unsaturated
smaller because of the armature-resistance volt drop and portion of its magnetisation curve. This
armature reaction, the voltage across the field circuit also unbuilding process continues until the terminal
572 POWER PLANT ENGINEERING
IaRa voltage
drop I
Drop owing to
voltage (V)
Rated
load decreasing If
Shunt field
Volts
current
Breakdown resistance line
point
Hence, OB is the maximum no-load or open circuit Let IaRa = Voltage drop in armature, and
voltage. Ish = Increase in shunt field current to
counteract the demagnetising effect.
Y
S Now if a right-angled triangle say lmn is drawn as
Internal char that ln = voltage drop in armature, and mn = shunt field
B acteristic
A Exte current. The triangle lmn is called as the drop reaction
L D rn al c F
har triangle.
ac
M
E H t
G
E/Ia In order to draw external and internal characteristic
erist
V/I repeat the process as in A with following modifications in
O.C
ic
steps 4 and 9 respectively.
.C.
C
ce line parallel to the line lm of triangle lmn and complete the
a tu re resistan
N Arm U T triangle LMN. Now from the points L and M draw vertical
X
O lines cutting X-axis at points N and M. Now LN represents
Shunt field current, Ish Load current, I
Armature current, Ia the generated e.m.f. MM represents the terminal voltage,
LN represents the voltage drop in armature due to armature
Fig. 12.26. (b) Determination of external and internal resistance ON is the shunt field current to induce an e.m.f.
characteristic from O.C.C. represented by LN and NM is the increase in shunt field
4. Take any point (say L) on the O.C.C. and draw current to counteract the demagnetising effect.
an ordinate, say, LMN intersecting field resistance line at 5. Take TU = shunt field current ON (scale being
M and X-axis at N. Now LN represents the generated e.m.f., different). OU represents the load current corresponding
MN represents the terminal voltage and LM represents to the armature current represented by OT and terminal
voltage drop in armature. voltage MM.
5. From points L and M draw horizontal lines cutting
Voltage control of shunt generators :
vertical axis say at point D and E respectively.
— The terminal voltage of a shunt generator may
6. Draw armature resistance line OC.
be kept constant at all loads with the use of
7. From point E, draw line EF parallel to line OC adjustable resistance, called a field rheostat,
cutting line LD produced at F. Hence, F is lying on the
connected in series with the shunt-field circuit.
internal characteristic.
By adjusting the resistance of the rheostat to
Similarly other points can be obtained and internal suit the load on the machine, changes in
characteristic may be drawn through these points.
terminal voltage with load may be prevented.
8. From point F draw vertical line intersecting When the load changes gradually, hand control
produced line ME at any point G and X-axis say, at point of the rheostat may be used, although automatic
T. Since FG = LM = CT, hence point G lies on the curve
control employing a voltage regulator is far more
representing relation between armature current and
satisfactory.
terminal voltage.
— The terminal voltage may also be controlled
9. Take TU = shunt field current (Ish) ON (scale being
different). OU represents the load current corresponding automatically by the addition of a series-field
to armature current represented by OT and terminal winding. This method has the advantage of
voltage OE. being automatic, cheap and generally
10. From point U draw a vertical line intersecting satisfactory.
line EG at H. Point H lies on the external characteristic. Series Generator :
Similarly other points may be obtained and curve The field winding of a series generator is connected
may be drawn, which is the required external characteristic. in series with the armature winding as shown in Fig. 12.27.
(B) Taking armature reaction into account : It consists of a few series of heavy wire, capable of carrying
Here, in addition to considering the voltage drop in the output current of the machine without overheating. The
armature, voltage drop due to armature reaction is also characteristic curves of a D.C. series generator are drawn
taken into account. as given below :
574 POWER PLANT ENGINEERING
Series E/Ia
field 1 Drop due to arm.
3 reaction
2 Arm. and series field
A drop
B E/Ia
Volts
Supply Armature E
V/I
I C
O Line current I (= Ia)
Fig. 12.27. Connection diagram for obtaining the saturation
curve of a series generator.
Fig. 12.29. Characteristic curves of a D.C. series generator.
— The saturation curve (1) may be obtained in a
It may be noted that the readings cannot begin at
manner exactly similar to that already described
zero load as with the shunt generator, for if the resistance
for the shunt machine. The series-connected
of the circuit including armature, series field and load is
generator is illustrated in Fig. 12.27. The series
increased beyond a certain critical value, the generator
connected generator illustrated in Fig. 12.28
unbuilds and loses its load entirely. Thus, if OA is the
must be capable of safely carrying the maximum
resistance line for the circuit the terminal voltage is the
current to be used, or about 125 per cent of rated
ordinate to the curve at A. When the resistance of the circuit
load current. A plot of simultaneous readings
is gradually increased, the load falls off along the curve,
of generated voltage and field current, taken at
and A approaches B. When the resistance line finally
a rated speed, yields the magnetisation curve 1
becomes tangent to the curve, however, operation becomes
of Fig. 12.29.
unstable, and any slight further increase in the resistance
causes the machine to unbuild its voltage and lose its load.
The resistance that brings about this condition is called
Series Series the critical resistance. Therefore, to begin with, the
field divertor resistance of the circuit must be reduced below the critical
value before the generator delivers any load.
Interpole
+ — Internal characteristic (curve 3). This curve
Load
Main E4
Over
Cumulative
switch Long shunt
Flat generator
Short Series E3 compound
Shunt winding
Interpoles E2
Terminal voltage, V
Under
Load
E1
winding
Shunt generator
Shunt
Armature Armature
Differential
compound
Rated load
generator
Shunt
regulator
Load current, I
Fig. 12.30. Connection diagrams for a compound generator. Fig. 12.32. External load voltage characteristics of cumulative
and differential compound generators.
Regardless of the method of connection, the terminal
voltage V of the short shunt or long shunt compound Over compound generator. An over compound
generator is same, V = Eg – (Ise . Rse + IaRa). generator is one whose terminal voltage rises with the
The generator voltage, Eg, of a compound generator application of load so that its full-load voltage exceeds its
no-load voltage (negative regulation).
is the result of the combination of m.m.f.’s produced by the
series (IseTse) and shunt (IshTsh) ampere-turns due to Flat compound generator. A flat compound
generator has a load-voltage characteristic in which the
current which flows in their field windings. In a compound
no-load and full-load voltages are equal (zero per cent
generator, the shunt field predominates and is much the
regulation).
stronger of the two. When the series field m.m.f. aids the
Undercompound generator. An undercompound
shunt field m.m.f., the generator is said to be ‘cumulatively
generator has a load characteristic in which the full load
compounded’ (see Fig. 12.31). When the series field m.m.f. voltage is somewhat less than no-load voltage, but whose
opposes the shunt field m.m.f., the generator is said to be aiding series-field ampere-turns cause its characteristic to
‘differentially compounded’ [see Fig. 12.31 (b)]. have better regulation than an equivalent shunt generator.
576 POWER PLANT ENGINEERING
— Most commercial compound D.C. dynamos, a separate source of supply. Consequently they are generally
whether used as generators or motors, are used where self-excited are relatively unsatisfactory. These
normally supplied by the manufacturer as are used in Ward Leonard systems of speed control, because
overcompound machines. The degree of self-excitation would be unsuitable at lower voltages.
compounding (over, flat or under) may be (ii) These generators are also used where quick and
adjusted by means of diverter which shunts the requisite response to control is important (since separate
series field. excitation gives a quicker and more precise response to
Characteristics of Differential Compound the changes in the resistance of the field circuit).
Generator : Shunt generators :
— The differential compound generator is defined (i) These generators are used to advantage, in
as that compounding produced when the series conjunction with automatic regulators, as exciters for
field m.m.f. opposes the shunt field m.m.f. The supplying the current required to excite the fields of A.C.
difference in current direction of the two generators. The regulator controls the voltage of the exciter
windings is shown in Fig. 12.31 (b), where for by cutting in and out some of the resistance of the shunt-
the sake of clarity, the series field winding is field rheostat, thereby holding the voltage at whatever
shown above (rather than directly around) the value is demanded by operating conditions. This is one of
shunt field winding. the most important applications of shunt generators.
— Fig. 12.33 shows the load characteristics of (ii) Shunt generators are used to charge batteries.
differential compound generator. In this application the voltage should drop off slightly as
the load increases, because the voltage of a lead battery is
lower when battery is discharged than when battery is
charged. When it is discharged, however, the battery can
stand a large charging current than when it is charged.
Terminal voltage, V
drop in the line is compensated for by the rising — It is usually of relatively small kVA capacity
characteristic of the generator. and low voltage rating. It resembles a D.C.
When the point of utilisation is near the generator, a generator in general appearance except that it
flat-compounded machine may be used. has slip rings instead of a commutator. The field
(ii) Differentially compounded generator finds an excitation must be direct current, and therefore,
useful application as an arc welding generator where the must be supplied from an external direct current
generator is practically short circuited every time the source.
electrode touches the metal plates to be welded.
2. Revolving field type alternator
(iii) Compound generators are used to supply power
to : — It has a stationary armature or stator, inside of
which the field poles rotate.
— Railway circuits,
— Motors of electrified steam rail-roads, — Most alternators are of the revolving field type,
— Industrial motors in many fields of industry, in which the ‘revolving field structure’ or ‘rotor’
has slip rings and brushes to supply the
— Incandescent lamps, and
excitation current from an outside D.C. source.
— Elevator motors etc.
The armature coils are placed in slots in a
12.2.3. Alternator Current Generators laminated core, called the ‘stator’ which is made
up of a thin steel punchings or laminations
12.2.3.1. Introduction
securely clamped and held in place in the steel
— A machine for generating alternating currents frame of the generator. Usually the field voltage
is referred to an alternator. is between 100 and 250 volts and the amount of
— The term ‘A.C. generator’ is also frequently power delivered to the field circuit is relatively
used, in place of alternator and this is often small.
contracted to just ‘generator’ when it is obvious
The following are the advantages of the revolving
that as A.C. machine is meant. In older
literature the term ‘alternating current dynamo’ field type alternators :
will also be found, but the present tendency is 1. The armature windings are more easily braced
to reserve the use of the word dynamo for D.C. to prevent deformation under the mechanical stresses due
generators. to short-circuit currents and centrifugal forces.
— High-speed alternators driven by steam turbine 2. The armature (stator) windings must be insulated
differ considerably in their construction from the for a high voltage, while the voltage of field circuit is low
slow speed types and one distinguished by the (100 to 250 volts). It is much easier to insulate the high
use of the terms ‘turbo-alternator’ whilst the
voltage winding when it is mounted on the stationary
slow engine-driven machines one often
structure.
described as being of the ‘flywheel-type’.
3. Only a small amount of power at low voltage is
12.2.3.2. Classification and operating principle handled by the slip ring contacts.
— In D.C. generators, the field poles are stationary
4. It is easier to build and properly balance high-
and the armature conductors rotate. The
speed rotors when they carry the field structure.
alternating voltage induced in armature
conductors is converted to a direct voltage at 5. The armature winding is cooled more readily
the brushes by means of the commutator. because the stator core can be made large enough and with
— A.C. generators commonly called alternators, many air passages or cooling ducts for forced air circulation.
have no commutators as they are required to Operating principle (Revolving-field type). When
supply electrical energy with the alternating the rotor rotates, the stator conductors (being stationary)
voltage. Therefore, it is not necessary that are cut by the magnetic flux, hence they have induced e.m.f.
armature be the rotating member. produced in them. Because the magnetic poles are
Alternators, according to their construction, are alternately N and S, they induce an e.m.f. and hence
divided into the following two classifications : current in armature conductors, which first flows in one
1. Revolving armature type direction and then in the other. Hence, an alternating e.m.f.
2. Revolving field type. is produced in the stator conductors whose frequency
1. Revolving armature type alternator depends on the number of N and S poles moving past a
— It has stationary field poles and revolving conductor in one second and whose direction is given by
armature. Fleming’s right-hand rule.
578 POWER PLANT ENGINEERING
may circulate.
— The coils are shaped much like the coils of a
D.C. generator, the two sides of the coil being
approximately a pole pitch apart. All coils are
N S alike, and therefore, interchangeable. They are
insulated before being inserted in the slots and
are further protected by a horn-fibre slot lining.
When in place on the stator, the coils are
Slip rings connected together in groups to form a winding
of the required number of phases, three-phases
(a) Revolving armature
star-connected windings being common.
Laminated
stator
A.C. terminals
D.C. terminals
gap
S N Air
Stator
slots N S
Exciting
coils Rotor
– +
Note. All synchronous A.C. generators and motors
require direct current for excitation. Excitation is supplied Holes for
by a D.C. generator called an exciter. The capacity of the damper winding
exciter is only a small percentage of the rated capacity of
the alternator. The exciter may be directly connected to
the shaft of the alternator, or it may be driven by a separate
Fig. 12.35. Alternator.
electric motor, water wheel, or small turbine. Large power
stations usually have several exciters employing different
methods of drive as insurance against the failure of Stator slot
excitation.
N
Rivet holes
+
— These rotors are made from solid forgings of one cycle of e.m.f. would be generated when the field
alloy steel. The outer periphery of rotor has slots structure rotates through an angle subtended by a double
in which the field winding is placed. About 2/3rd pole pitch. Therefore, in a machine with poles, the number
of rotor pole pitch is slotted, leaving the 1/3rd of cycle of e.m.f. in one revolution will be p/2. If a machine
unslotted for the pole centre. Heavy wedges of has a speed of Ns revolutions per minute, the frequency
non-magnetic steel are forced into the grooves will be
in the teeth outside the field coils to keep the FG IJ
p N
field coils in position. H K
2
s per second.
60
— Cylindrical rotor machines have always
p Ns Ns p
horizontal configuration. Thus, f Hz ...(12.2)
2 60 120
— Since the rotors have large lengths of core forced
In order to keep the frequency constant, the speed
ventilation is necessary for proper cooling.
Ns must remain unchanged. Therefore, a synchronous
Forced air cooling is used up to about 50 MVA
generator (i.e., alternator) runs at a constant speed known
sizes and for bigger sizes hydrogen cooling is
as synchronous speed.
invariably employed because the conductivity of
hydrogen is about 7 times that of air. 12.2.3.4. Exciters
The alternator’s field requires magnetism. The permanent
Note. It may be worth mentioning that cylindrical rotors
magnets are unsuitable for the field of the alternator. Hence
will most likely be located on alternates where steam power
is readily available. Salient-pole rotors will be found where direct current is fed into the poles of the alternator so that
water power is the prime mover source of energy. Diesel one end is a north pole and the other a south pole. This
engine, gas engine, and gas turbine prime movers are direct current is supplied by a separate generator which
considered medium-speed machines, and their alternators is mounted on the same shaft as the alternator. Hence all
will also have salient poles. Where alternators are driven alternators have a separate exciter which generally produce
by other electrical machines, either A.C. or D.C. motors, high current and low voltage. In case of large machines
there are no such restrictions on the rotor construction. A there are two exciters known as main exciter and pilot
design is developed that is compatible with the space exciter. The pilot exciter is a well-saturated constant voltage
limitations, speed considerations, and heat dissipation for machine arranged to excite the main exciter.
both electrical machines. It may be noted here that the As the field strength depends on the D.C. exciting
terms high-speed and low-speed rotors are sometimes used current in the field magnet coils, the exciting or field current
synonymously with cylindrical and salient-pole rotors, is regulated accordingly to adjust the output voltage. In
respectively.
case of large machines the field current may be as high as
Bearings 400 amperes. To regulate the exciting current is obtained
by connecting the regulating resistance in the field circuit
— Although antifriction bearings are occasionally
of the exciter where comparatively low current has to be
used on alternators of the smaller ratings, the
handled. Fig. 12.40 shows such an arrangement.
great majority are furnished with oil-lubricated
babbitted bearings. For horizontal shafts these Alternator
will be self-contained ring-oiled bearings field winding
wherever design conditions permit. At higher
shaft peripheral speeds and higher bearing
loadings ring oiling is supplemented with
E
recirculation of externally cooled oil. The rings
may be eliminated, or they may be retained to
afford some degree of emergency oil supply in
Exciter Regulating
the event of a failure of the external system. Field resistance
Lead-base babbits are commonly used for journal resistance
if any
bearings, although tin-base babbit may be
employed for some heavy-duty application. Fig. 12.40. Voltage control of an alternator.
— Two principle types of thrust bearings are used It has been seen that the terminal voltage of the
on vertical alternators : the pivoted shoe type alternator depends not only the exciting current but also
and the spring type. on the load current and the power factor of the load. If no-
Frequency load terminal voltage is plotted against values of exciting
In case of a generator which has two poles, the current with the machine running at normal speed (field
induced e.m.f. passes through one complete revolution in current) then the open circuit characteristics or
one revolution of the machine. In a multipolar machine magnetisation curve is obtained. The voltage is directly
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 581
proportional to the flux per pole. The magnetisation curve (iii) Voltage drop due to armature reaction.
is determined by the properties of the magnetic circuit. If (i) Armature resistance. The voltage drop caused
the excitation of an alternator is adjusted to give normal by armature resistance per phase Ra is IRa and is in phase
voltage at no-load and then a load is applied, the terminal with current I. This drop, however, is practically negligible.
voltage changes, even though the speed is kept constant.
The voltage usually falls, but in certain circumstances it Effective resistance. The effective resistance of the
may actually rise. These changes may be due to armature winding is greater than the conductor resistance
(i) resistance of each phase winding, (ii) the reactance of as measured by direct current. This is because additional
each phase winding, (iii) the armature reactors. energy over purely I2R value is expended inside and
The exciter is generally a shunt wound D.C. machine. sometimes outside of the conductor, owing to the
For a new machine it is often necessary to apply the first alternating current.
excitation with a battery. Then later on the poles of the The chief sources of this additional energy loss are :
exciter have residual magnetism and thus require no (i) Eddy currents in the surrounding material ;
external help. However in no case of bigger machines, the
(ii) Magnetic hysteresis in the surrounding
pilot exciter may be started by the battery (in case of new
material ; and
machines only) and then with the residual magnetism in
the field magnets it will generate direct current. (iii) Eddy currents or unequal currents distribution
An exciter may be either directly coupled to the in the conductor itself.
alternator shaft or it may be driven through a belt or chain In many cases it is sufficiently accurate to measure
drive. the resistance of an armature by direct current and increase
Advantages of directly coupled exciters : it to a fictitious value, called the effective resistance, which
1. The machine as a unit is complete in itself and is large enough to take care of these extra losses. The exact
independent of outside sources for its operation. value can vary widely from 1.25 to 1.75, or more × D.C.
2. The voltage of the system can be maintained resistance, depending upon design. Extreme accuracy is not
independent of any auxiliary source of supply and is not necessary in this factor, since the voltage change due to
affected by faults there on. resistance is small in comparison to the changes produced
by leakage reactance and armature reaction.
Disadvantages :
(ii) Armature leakage reactance. The load
1. Armature fitting, commutator stresses, brush
current, flowing through the armature winding, builds up
chatter and ventilation, all require special attention.
local flux which on cutting the winding generates a counter
2. Exciter troubles may sometimes necessitate (or reactance) e.m.f. This effect gives the armature a
shutting down of the main set.
reactance which is numerically equal to 2fL. L, in henries,
3. With the high speeds in general use (1500 to 3000 is the leakage inductance of the winding. This armature
r.p.m.) difficulties such as balancing, alignment of shaft reactance is called the leakage reactance XL (also known
and other problems crop up. as Potier reactance XP) since the flux which causes it is
A.C. Exciters around the armature turns only and does not effect the feld
To avoid commutation difficulties as well as flux directly. This leakage flux (Fig. 12.41) is proportional
commutator maintenance, A.C. exciters with silicon or to the armature current, since the magnetic path it covers
germanium rectifiers have been developed for the largest is not normally saturated. XL varies some what with the
turbo alternators as well as for smaller machines ; the position of the armature and field poles. It is usually
current from the static floor mounted rectifiers is fed to assumed to be constant.
the rotor of the main machine through conventional
sliprings. The A.C. exciter is mounted on the main Leakage
generator shaft and may be designed to operate at any flux
economically convenient frequency, e.g. 100–150 Hz or
more.
12.2.3.5. Alternator on load
When load on an alternator varies, its terminal voltage
also varies. This variation in terminal voltage is due to the
following reasons :
(a) Deep, narrow, (b) Shallow, wide, (c) Shallow, wide,
(i) Voltage drop due to armature resistance. open slot open slot partially closed slot
(ii) Voltage drop due to armature leakage reactance
XL. Fig. 12.41. Slot-leakage flux.
582 POWER PLANT ENGINEERING
þ
ý
ü
(iii) Armature reaction. Armature reaction is the Lagging power factor load
Resultant mmf
magnetomotive force produced by the armature currents
in the armature conductors.
E
Unity power factor. At unity power factor,
I 1
armature reaction consists of distortion of the main field
flux. O N 2 S
2 1
Lagging power factor. When an alternator
operates with a laging power factor a m.m.f. is set up by (c)
Armature mmf
þ
ý
ü
the current in the armature conductors which opposes the O Total mmf
Leading power factor load
m.m.f. of the main field and causes a decrease in the main
Main field mmf
flux. This, in turn, results in decrease in the induced
voltage. The lower the value of lagging power factor, the Fig. 12.43. Effects of armature reaction.
greater will be the armature m.m.f. which will oppose and
weaken the field. Synchronous reactance. The leakage reactance
XL (or XP) and the armature reactance Xa may be combined
Leading power factor. In those limited
to give ‘synchronous reactance’ Xs.
applications where an alternator supplies a load with a
leading power factor, the armature current sets up m.m.f. Hence, Xs = XL + Xa
in the armature which aids the m.m.f. of the main field [The ohmic value of Xa varies with the power factor
and causes the main field flux to increase. Therefore, the of the load because armature reaction depends on load
voltage of the alternator will increase with an increase in power factor].
load current. The lower the value of the leading power factor, From the above discussion, it is clear that for the
the greater will be the armature m.m.f. aiding the m.m.f. of same field excitation, terminal voltage is decreased from
the main field to cause an increase in the main field flux. its no-load value Eo to V (for a lagging power factor). This
The following illustrations in Fig. 12.43 show how is because of :
the main field flux is affected by the armature m.m.f. for (i) Drop due to armature resistance IRa.
different load power factors. For ease of illustration, a two- (ii) Drop due to synchronous reactance IXs.
pole rotating type alternator is used. However, the same Therefore, total voltage drop in an alternator under
conditions take place in the revolving field type alternator. load is
A study of illustrations in Fig. 12.43 and vector
= IRa + jIXs = I(Ra + jXs) = IZs
diagrams for different power factor loads shows that the
voltage drop due to inductive reactance and armature where Zs is known as ‘synchronous impedance’. (The word
reaction are the same in their effect on the termianl voltage. synchronous simply refers to the working conditions).
Both of these effects are proportional to the armature Fig. 12.44 shows the vector diagram for the above
current. fact.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 583
s
IZ
E
O a
where Z = R2 X L 2
V IX
IR IX s I = Armature current/phase and
L
a
= Load power factor angle.
I
12.2.3.6. Voltage regulation
Fig. 12.44 — When an alternator is subjected to a varying
load, the voltage at the armature terminals
Vector Diagrams of a Loaded Alternator. The varies to a certain extent, the amount of this
vector diagrams for unity power factor, for lagging power variation determines the regulation of the
factor and for leading power factor have been shown in machine. The numerical value of regulation is
Figs. 12.45, 12.46 and 12.47 respectively. All these defined as the percentage rise in voltage when
diagrams apply to one phase of a 3-phase machine. full-load at the specified power-factor is switched
Diagrams for the other phases can also be drawn in the off, the excitation being adjusted initially to give
same way. normal voltage. Thus,
E V
% Regulation ‘up’ = o × 100 ...(12.4)
V
IXa This gives a lower figure than the percentage drop
Eo
s
IZ
E
O a to 10 per cent at unity power factor, but the
IX voltage rise is considerably increased at lagging
IZ
V IR IX
L
s power-factors. At 0.8 lagging power- factor the
a
value lies between 25 and 35 per cent, or even
I
more.
— Close regulation is not desired, since such an
Fig. 12.46. Lagging power factor. alternator would deliver an excessive current if
accidentally short-circuited. Coarse regulation
adds to the protection of the machine, and it is
IX a
usual to design an alternator with a
Eo
IX s considerable amount of internal reactance, since
IZs
The following indirect methods are used to (ii) Plot short-circuit characteristic (S.C.C.) from the
determine voltage regulation : data given by short-circuit test.
1. Synchronous impedance or E.M.F. method. Both these curves are drawn on a common field-
2. The Ampere-turn or M.M.F. method. current base.
3. Zero power-factor or Potier method. Consider a field current If. Corresponding to this
All these methods require : field current the O.C. voltage is E1. When winding is short-
circuited, the terminal voltage is zero. Hence, it may be
(i) Armature (or stator) resistance Ra.
assumed that the whole of this voltage E1 is being used to
(ii) Open-circuit/no-load characteristic. circulate the armature short-circuit current I1 against the
(iii) Short-circuit characteristic (but zero power synchronous impedence Zs.
factor lagging characteristic for Potier method). E1 = I1Zs
(i) Value of Ra. Armature resistance Ra per phase
E1 (open-circuit)
can be measured directly by voltmeter and ammeter or Zs =
I1 (short-circuit)
method or by using wheatstone bridge. The effective value
of Ra, however, under working conditions is increased due (iii) Find synchronous reactance, Xs as follows
to skin effect. The value of Ra so obtained is increased by
60 per cent or so to allow this effect. Generally, a value 1.6 Xs = Zs2 Ra2
times D.C. value is taken. (Ra can be found as discussed earlier)
(ii) Open-circuit characteristic. This type of (iv) After finding Ra and Xs vector diagrams for any
characteristic (as in D.C. machines) is plotted by running load any power factor may be drawn. Three cases are
the machine on on-load and noting the values of induced considered in Fig. 12.49, (a) unity power factor, (b) lagging
voltage and field excitation current. power factor, and (c) leading power factor.
(iii) Short-circuit characteristic. Short-circuit — Unity power factor. Refer to Fig. 12.49 (a)
characteristic is obtained by short-circuiting the armature
OC2 = (OA + AB)2 + BC2
(i.e., stator) windings through a low resistance ammeter.
The excitation is so adjusted as to give 1.5 to 2 times the E02 = (V + IRa)2 + (IXs)2
value of full-load current. The speed (not necessarily
synchronous) is kept constant during the test. E0 = (V IRa )2 ( IX s )2 ...(12.5)
Synchronous Impedance Method. This method — Lagging power factor. Refer to Fig. 12.49 (b),
involves the following steps : OC2 = (OA + AB)2 + (BD + DC)2
(i) Plot the open-circuit characteristic (O.C.C.) from = E02 = (V cos + IRa)2 + (V sin + IXs)2
a given data as shown in Fig. 12.48.
E0 = (V cos IRa )2 (V sin IX s )2
...(12.6)
E1 — Leading power factor. Refer to Fig. 12.49 (c),
OC2 = (OF + FD)2 + (BD – BC)2
C.
Zs
E.M.F. (O.C.)
O.
S.C. current
Field current, If O I
(or ampere turns) V A IRa B
Fig. 12.48. O.C. and S.C. test curves of an alternator. (a) Unity power factor
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 585
is almost zero lagging and field ampers turns From (ii) the reduction in voltage due to armature
are used entirely to overcome the armature reaction is found out and voltage drop due to armature
reaction. Therefore, If gives demagnetising leakage reactance (also called Potier reactance) XL is found
ampere-turns on full-load. from both (i) and (ii) both. By combining the two, E0 can be
— Now let us consider a general case when the calculated.
alternator supplies full-load current at a power The above two curves are similar and displaced
factor of cos . horizontally by the m.m.f. due to armature reaction in terms
(i) Draw OL repressing If to give full-load rated of the field current.
voltage, V (or more exactly V + IRa cos ). — Zero power factor, full-load voltage excitation
(ii) Draw LM at an angle (90° ) representing If characteristic can be drawn by knowing two
to give full-load current on short-circuit points L and M. Point L is obtained from a short
(+ve sign for lagging p.f. and –ve sign for leading circuit test with full-load armature current.
p.f.). Hence OL represents field current (excitation)
(iii) Find field current If, measuring OM, which will required to overcome demagnetising effect of
give open circuit e.m.f. E0 which can be armature reaction and to balance leakage
determined from open circuit characteristic reactance drop at full-load. Point M is obtained
(O.C.C.). when full-load current flows through the
armature and wattmeter reading is zero. Zero
The percentage regulation then, can be obtained
power factor curve may be drawn as follows :
from the following relation :
(i) From M draw line MN equal and parallel to OL.
E0 V
% Regulation =
× 100. (ii) Through point N draw a line parallel to initial
V
straight part of O.C.C. (parallel to OS), cutting
— Regulation given by this method is much lower
the O.C.C. at P.
than that given by the synchronous impedance
method, but it is nearer the correct value. This (iii) Join PN and drop a perpendicular PQ on MN.
method is called the ‘Optimistic’ method. (iv) Impose the triangle MPQ at various-points of
Zero Power Factor or Potier Method. This O.C.C. to obtain corresponding points on the zero
method gives more accurate results since it is based on the power factor curve.
separation of armature-leakage reactance drop and the In triangle MPQ :
armature reaction effects. The following experimental data Length PQ represents leakage reactance drop (IXL).
is required in this method :
Length MQ represents armature reaction excitation.
(i) No-load or open circuit curve.
(ii) Full-load zero power factor curve (not S.C.C.). G
I2
O.C.C. E0 J
F
Zero p.f. full I 90° + f
load curve I1
90° IXa
P
90° E
O D
f V
A
N Q M IXL
B IRa
Terminal voltage
P¢ C
Fig. 12.52
M¢
N¢Q¢ Potier Regulation Diagram. Following is the
procedure to draw Potier regulation diagram :
S (i) Draw OA horizontally to represent terminal
voltage V on full load and OB to represent load current (I)
at a given power factor.
O T L (ii) Draw AC(= IRa), voltage drop due to resistance
Ra (if resistance is given) parallel to OB.
Field current
(iii) Draw CD perpendicular to AC and equal to
Fig. 12.51 reactance drop IXL.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 587
Now OD represents generated e.m.f. E. is reflected directly in the final efficiency calculation.
(iv) From O.C.C., find the field current I1 Efficiency is therefore calculated by ‘measurement of losses’
corresponding to this generated e.m.f. E and draw OF method which entails the following advantages :
(equal to I1) perpendicular to OD. Draw FG parallel to load (i) At any one time, only part of the losses need be
current OB (i.e., I) to represent excitation (field current) provided. Therefore the source of power required for testing
equivalent to full load armature reaction. has a capacity of less than 5% of the rating of the alternator.
OG gives total field current required. (ii) There is no need to put an electric load on the
(v) If the load is thrown off, then terminal voltage alternator.
will be equal to generated e.m.f. corresponding to field (iii) Greater accuracy can be obtained since electrical
excitation OG. Hence e.m.f. E0 may be obtained from O.C.C. instruments can be used for all measurements.
corresponding to field excitation OG. Vector OJ will lag (iv) An inaccuracy that occurs in the test is not
behind vector OG by 90°. DJ represents voltage drop due directly reflected in the final efficiency calculation, since
to armature reaction. the error occurs on only a small portion of the name plate
Now regulation may be obtained from the following rating.
relation : Use of a calibrated D.C. motor to drive the
E V alternator. A quite accurate and simple method of
% Regulation = 0 × 100. determining the losses is to use a calibrated D.C. motor to
V
drive the alternator. The motor is calibrated in the sense
12.2.3.7. Losses and efficiency that all its losses have been determined for varying
Losses. The following losses occur in an alternator : conditions of operation, so that its output is then readily
1. Copper losses. These losses occur in the obtained.
armature winding and in the field coils. This method involves the following procedural
2. Core loss. The core loss consists of eddy-current steps :
and hysteresis loss in the pole faces, teeth, and stator core Step 1. Drive the alternator at synchronous speed,
due to the flux resulting from the combined rotor and but without field excitation. The D.C. motor output is the
armature fields. alternator input, and hence its friction and windage loss.
3. Friction and windage loss. This loss is due to Step 2. Repeat step 1, but this time with field
the bearing and brush friction and to the power required excitation. The excitation should be that at which the
to circulate the cooling air. alternator normally operates. If this is unknown, then the
open-circuit voltage is adjusted to be equal to the rated
4. Load loss. This is due to the armature leakage
voltage plus the internal voltage drops as determined by
flux which causes eddy-currents and hysteresis in the iron
one of the methods used to calculate voltage regulation.
surrounding the armature conductors. If, however, effective
resistance is used to calculate the armature copper loss, The difference between the motor output of step 2
then these load losses are also included in the calculation. and that of step 1 is the core loss.
Efficiency. The efficiency of an alternator is Step 3. Short-circuit the armature and adjust the
calculated as follows : field current to obtain rated line current. The difference
Alternator efficiency between this motor output and that of step 1 is the armature
copper loss plus load loss. It is assumed that the flux density
Output kVA(p.f.) under short-circuit conditions is so low as to make the core
= = .
Output + Losses kVA(p.f.) + Losses loss negligible.
Maximum efficiency occurs at that load point where Step 4. The field copper loss is measured by simple
the constant losses (friction, windage, core loss and field D.C. measurement.
copper loss) are equal to variable losses (armature copper
12.2.3.8. Parallel operation of alternators
and load loss). The maximum efficiency usually occurs at
about 80% of full load. Necessity. Alternators may be put in parallel because of
Determination of losses. Losses may be the following reasons :
determined by the following methods : 1. Local or regional power use may exceed the power
Measurement of losses method. As in most of a single available generator.
electric machines, efficiency measurement of an alternator 2. Parallel alternators allow one or more units to be
by direct loading is rather impractical. It may also be a shut down for scheduled or emergency maintenance while
physical impossibility to obtain the required load, and even the load is being supplied with power.
if it could be obtained the cost may be prohibitive. Also, 3. Generators are inefficient at part load, so shutting
the measurement of the mechanical power input is down one or more generators allows the remaining load to
somewhat difficult, and any inaccuracy with measurement be carried with less machines that are efficiently loaded.
588 POWER PLANT ENGINEERING
4. Load growth can be handled by added machines Violation of these requirements for paralleling would
without disturbing the original installation. result in circulating currents between the machines varying
5. Available machine prime movers and generators from uneconomic, to serious, to disastrous.
can be matched for economic first cost and flexible use. 12.2.3.9. Alternator synchronising procedure
Requirements for paralleling. The requirements It may logically be assumed that one alternator is placed
for paralleling include the requirements for D.C. machines in parallel with one or more other alternators only when
plus a few others. additional load requires it. Those alternators already
1. The voltages must be the same at the paralleling carrying load are known as the running machines, while
point or junction even though not the same at the that which is to be placed in the system is known as the
alternators. incoming machine. At the time of synchronizing, the
following conditions must be met.
2. The phase sequence for three phase (or any
1. The effective voltage of the incoming alternator
multiple phase) must be the same at the paralleling point.
must be exactly equal to that of the others, or of the bus-
3. The incoming machine must be in phase at the bars connecting them.
moment of paralleling. It will stay in phase under normal 2. The phase rotation, or sequence of the running
conditions after paralleling. It is important to recognize and incoming alternators must be the same.
that phase sequence and in phase are not the same thing. 3. The individual phase voltages which are to be
4. The line frequencies must be identical at the connected to each other must be in exact phase opposition.
paralleling point. In the vast majority of cases, this means This is the same as saying that D.C. generators must
the same frequency at the generator because frequency be connected + to + and – to –.
changing is not economic. Mixed frequencies must be 4. The frequencies should be the same, although it
paralleled through some frequency conversion means for is more desirable that the frequencies at the instant of
compatibility at the point of interconnection. paralleling be almost, but not quite, identical.
5. The primemovers must have relatively similar Synchronizing lamps :
and drooping speed-load characteristics. This is to prevent — To satisfy the first condition of paralleling (i.e.,
a machine with a rising speed load characteristic from effective voltages be the same) a voltmeter can
taking more and more of the load until if fails from overload. be used as shown in Fig. 12.53.
Voltmeter switch
Load
Synchronizing
switch
Running Incoming
D.C. machine machine D.C.
1 2
L
L
L
— Satisfaction of the other conditions of phase The procedural steps for putting incoming alternator
sequence, voltage opposition, and frequency may in parallel with the running machine are as follows :
be determined by the use of the incandescent Step 1. The prime mover of the incoming machine
lamps connected between the two machines is started, and the alternator is brought up to near its rated
(Fig. 12.53). The auxiliary equipment is omitted speed.
to simplify the sketch. Step 2. By adjusting the field current, the terminal
At any instant it is seen that the voltage across the voltage of incoming machine is made the same as that
lamp is the sum of the individual phase voltages. running alternator.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 589
The lamp in the circuit will now flicker at a rate In case of high-voltage alternators, the lamps are
equal to the difference in frequency of the two alternators. connected through transformers to obtain the nominal
If the phases are properly connected, all lamps will be bright voltages for which lamps are rated.
and dark at the same time. If this is not the case, then it Synchronoscope synchronization. In large
means that the phase sequences are not correct, and it is central station installations, an additional device called a
merely necessary to interchange two of the line leads of synchronoscope (Fig. 12.54) is used. A synchronoscope has
the incoming machine. a rotating hand and a dial labelled with slow and fast
Step 3. Further adjustment of the incoming prime direction arrows to show the incoming machine speed
mover is now necessary, until the lamps flicker at a very relation. In addition, an index point shows the actual
low rate, usually less than one dark period per second. in-phase position. During synchronization, as the incoming
Step 4. Final adjustment of the incoming voltage machine rotational speed approaches near synchronism,
again made and the synchronizing switch is thrown in the the speed of the synchronoscope hand drops enough to
middle of a dark period. The voltage across the lamps varies become visible. The hand speed is proportional to the
from zero to twice the phase voltage, and therefore, the difference in speed. The slow indication is accompanied with
lamps must be rated for this higher voltage. It is not an arrow showing that counter-clockwise hand rotation
convenient, however, to stock special lamps for this purpose, means below synchronous speed. Similarly clockwise
and two lamps of standard voltage ratings may be rotation means above speed. When the speeds are matched
connected in series in each line. as that the hand speed is very slow, the hand is matched
The lamp method has the following advantages and until it points to the index mark, where upon the paralleling
disadvantages. switch may be closed.
Advantages :
(i) Equipment is inexpensive.
(ii) Proper phase sequence is readily obtained.
Slow
Fast
Disadvantages :
(i) Lamps go dark at somewhat less than half their
rated voltage, and so the synchronizing switch might be
closed when there is a considerable phase difference
between the machines, with a high circulating current
resulting in possible damage to the machines. An
Fig. 12.54. Synchronoscope.
experienced operator, however, can minimize this danger,
since he can quickly learn to estimate the middle of the There are following three principal types of
dark period. synchronoscopes :
(ii) The lamp filament can burn out. (i) Polarized vane. (ii) Moving iron.
(iii) The flicker of the lamps does not indicate which (iii) Crossed coil.
machine has the higher frequency. All are used similarly. However, none of the types
There are two other lamp methods which are given will detect an out-of-phase sequence condition. They are
below : used as a convenient and accurate means of routinely
— If the lamps are connected across the phases, achieving synchronous speed and in phase indications. The
that is, P to Q, Q to R, R to P, they will again phase sequence problem is really an original test problem
flicker in unison. This time, however, the proper since, once sorted out, the phase sequence will remain
synchronizing moment occurs when all three are correct until repair or other circuit changes are needed.
in the middle of a bright period. This has the 12.2.3.10. Cooling of alternators
advantage of avoiding synchronizing when the
lamps may have burned out, but it is more Necessity of cooling. Due to the various losses occurring
difficult to estimate the middle of a bright period in the alternator, there is a temperature rise in various
than the middle of a dark one. parts of the alternator and winding insulation. To prevent
the temperature rise exceeding the maximum permissible
— In the third lamp method, known as the ‘two-
value, every alternator requires continuous cooling during
bright one-dark method,’ only two of the lamps
its operation.
are cross-connected. Thus the connections are
phase P to P, Q to R and R to Q. This method Cooling methods :
supposedly avoids the disadvantages of both 1. Open system using air. In this system the cold
previous lamps methods, but actually may be air is taken in from the atmosphere with the help of the
more confusing to the eye. fan and passed through the machine. The outcoming hot
590 POWER PLANT ENGINEERING
air is either discharged to atmosphere or into the machine 7. The cooling surface required for H2 cooling is
hall for station warming. Due to the difficulty of removal considerable smaller than that needed for air coolers due
of all dust particles from the air entering the machine they to high heat transfer rates.
are rarely used and that too on alternators having capacity
8. The reliability of the insulation increases and its
upto 3 MW.
life span is prolonged.
2. Closed system using air. In this system a given
9. The ‘corona’ effects on the conductors in windings
volume of air is circulated continuously through the
are less deleterious in hydrogen atmosphere than in air.
alternator. The discharged hot air is cooled to about 40°C
This also increases the life of winding.
through heat exchangers before it is recirculated through
the alternator. This system is universally used for large Disadvantages :
machines. 1. High cooling cost.
Advantages and disadvantages of closed 2. Overall capital and maintenance cost is high.
system over open system : 3. Gas may leak through the casing. For this reason
Advantages : the casing is made explosion proof against any pressure
which can be developed by explosive mixture of hydrogen
1. Quieter operation of the station.
and air.
2. No filter is required.
4. The major problem is to effectively seal the shaft
3. Less possibility of dust and impurities deposition
glands at the alternator hourings.
in the machine passages.
5. A high degree of hydrogen purity is required to
4. It is easier to combat a fire in an alternator since
ensure high efficiency and avoid explosions, and this
supply of fresh air is absent.
necessitates hydrogen purity, pressure and temperature
5. Appearance is quite good. recorders.
Disadvantages :
The only disadvantage is that this system is costly. 12.3. TRANSFORMERS
Hydrogen cooling 12.3.1. General Aspects
The gaseous hydrogen is better cooling medium than Although the transformer is not classified as an electric
air (air-cooling is successfully used upto 100 MW generating machine, the principles of its operation are fundamental
units) and now-a-days it is universally used in almost all for the induction motor and synchronous machines. Since
thermal power plants upto 200 MW capacity alternators. A.C. electric machines are normally built for low
The use of hydrogen gas as the cooling medium in frequencies only the low frequency power transformer will
closed circuit cooling offers the following be considered in this text.
Advantages : When energy is transformed into a higher voltage
1. The thermal conductivity of hydrogen is almost the transformer is called a step-up transformer but when
seven times that of air. Its specific heat is 14.5 times that the case is otherwise it is called a step-down transformer.
Most power transformers operate at constant voltage, i.e.,
of air. The overall heat transfer with forced cooling may be
if the power varies the current varies while the voltage
as 2 to 3 times that of air.
remains fairly constant.
2. Less windage losses since the density of hydrogen
Applications. A transformer performs many
1 important functions in prominent areas of electrical
is th that of air.
14 engineering.
3. Due to lower windage losses and better heat — In electrical power engineering the transformer
transfer in the cooler, less cooling water is required. makes it possible to convert electric power from
a generated voltage of about 11 kV (as
4. Less space is occupied by the hydrogen cooled
determined by generator design limitations) to
machines.
higher values of 132 kV, 220 kV, 400 kV, 500 kV
5. The noise is considerably reduced due to lighter and 765 kV thus permitting transmission of
cooling medium and lower friction. huge amounts of power along long distances to
6. The fire risk is reduced in the event of electrical appropriate distribution points at tremendous
breakdown as oxygen is not present to maintain combustion savings in the cost of transmission lines as well
of the insulation material. as in power losses.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 591
— At distribution points transformers are used to — A tapped transformer is one whose windings are
reduce these high voltages to a safe level of 400/ fitted with special taps for changing its voltage
230 volts for use in homes, offices etc. or current ratio.
— In electric communication circuits transformers — Oil and dry transformers. To avoid the
are used for a variety of purposes e.g., as an detrimental effect of the air on the winding
impedance transformation device to allow insulation and improve the cooling conditions
maximum transfer of power from the input of the transformer its core together with the
circuit to the output device. windings assembled on it is immersed in a tank
— In radio and television circuits input filled with transformer oil. Such transformers
transformers, interstage transformers and are called oil transformers. Transformers not
output transformers are widely used. immersed in oil are called dry transformers.
— Transformers are also used in telephone circuits,
instrumentation circuits and control circuits. 12.3.3. Working Principle of a Transformer
12.3.2. Basic Definitions A transformer operates on the principle of mutual
inductance, between two (and sometimes more) inductively
— A transformer is a static electromagnetic device
coupled coils. It consists of two windings in close proximity
designed for the transformation of the (primary)
as shown in Fig. 12.55. The two windings are coupled by
alternating current system into another
magnetic induction. (There is no conductive connection
(secondary) one of the same frequency with other
between the windings). One of the windings called primary
characteristics, in particulars, other voltage and
current. is energised by a sinusoidal voltage. The second winding,
called secondary feeds the load. The alternating current in
— As a rule a transformer consists of a core
the primary winding set up an alternating flux () in the
assembled of sheet transformer steel and two
core. The secondary winding is linked by most of this flux
or several windings coupled electromagnetically,
and in the case of autotransformer, also and e.m.fs. are induced in the two windings. The e.m.f.
electrically. induced in the secondary winding drives a current through
the load connected to the winding. Energy is transferred
— A transformer with two windings is called
from the primary circuit to the secondary circuit through
double-wound transformer ; a transformer with
three or more windings is termed a triple wound the medium of the magnetic field.
or multi-winding one.
Laminated core
— According to the kind of current, transformers
are distinguished as single-phase, three-phase
and poly-phase ones. A poly-phase transformer
winding is a group of all phase windings of the f
same voltage, connected to each other in a Secondary
definite way. winding
— Primary and secondary windings. The Primary
transformer winding to which the energy of the winding
alternating current is delivered is called the
primary winding ; the other winding from which
energy is received is called the secondary
winding. Fig. 12.55. Two winding transformer.
— In accordance with the names of the windings,
In brief, a transformer is a device that :
all quantities pertaining to the primary winding
as for example, power, current, resistance etc., (i) transfers electric power from one circuit to
are also primary, and those pertaining to the another ;
secondary winding secondary. (ii) it does so without change of frequency ; and
— h.v. and l.v. windings. The winding connected (iii) it accomplishes this by electromagnetic induction
to the circuit with the higher voltage is called (or mutual inductance).
the high-voltage winding (h.v.), the winding
connected to the circuit with the lower voltage 12.3.4. Transformer Ratings
is called the low-voltage winding (l.v.). If the The rated quantities of a transformer, its power, voltage,
secondary voltage is less than the primary one, frequency, etc. are given in Manufacturer’s name plate,
the transformer is called a step-down which should always be arranged so as to be accessible.
transformer and if more-a step-up transformer. But the term ‘rated’ can also be applied to quantities not
592 POWER PLANT ENGINEERING
indicated on the name plate, but relating to the rated duty, 2. A core, which in case of a single-phase distribution
as for example, the rated efficiency, rated temperature transformers usually comprises cold-rolled silicon-steel
conditions of the cooling medium, etc. : strip instead of an assembly of punched silicon-steel
— The rated duty of a transformer is determined laminations such as are used in the larger power-
by the quantities given in the name plate. transformer cores. The flux path in the assembled core is
— The rated power of the transformer is the power parallel to the directions of steel’s grain or ‘orientations’.
at the secondary terminals, indicated in the This results in a reduction in core losses for a given flux
name plate and expressed in kVA. density and frequency, or it permits the use of higher core
densities and reduced size of transformers for given core
— The rated primary voltage is the voltage
losses.
indicated in the transformer name plate ; if the
primary is provided with taps, the rated tapped Other necessary parts are :
voltage is specially noted. — A suitable container for the assembled core and
— The rated secondary voltage is the voltage across windings.
the transformer secondary terminals at no-load — A suitable medium for insulating the core and
and with the rated voltage across the primary its windings from each other and from the
terminals ; if the secondary winding has taps, container.
then their rated voltage is specially indicated. — Suitable bushings for insulating and bringing
— The rated currents of the transformer, primary the terminals of the windings out of the case.
and secondary, are the currents indicated in the The two basic types of transformer construction are :
name plate of the transformer and calculated 1. The core type.
by using the corresponding rated values of 2. The shell type.
power and voltage. The above two types differ in their relative
12.3.5. Kinds of Transformers arrangements of copper conductors and the iron cores. In
the ‘core type’, the copper virtually surrounds the iron core,
The following kinds of transformers are the most important while in the ‘shell type’, the iron surrounds the copper
ones : winding.
1. Power transformers. For the transmission and
distribution of electric power. 12.3.6.1. Core type transformer
2. Auto-transformers. For converting voltages The completed magnetic circuit of the core-type transformer
within relatively small limits to connect power systems of is in the shape of a hollow rectangle, exactly as shown in
different voltages, to start A.C. motors etc. Fig. 12.56 in which I0 is the no-load current and is the
flux produced by it. N1 and N2 are the number of turns on
3. Transformer for feed installations with
the primary and secondary side respectively.
static convertors. (Mercury are rectifiers, ignitions, semi-
conductor valves, etc.). When converting A.C. into D.C.
(rectifying) and converting D.C. into A.C. (inverting). f
I0
4. Testing transformers. For conducting tests at
high and ultra-high voltages. Primary
5. Power transformers for special applications. A.C. Supply V1 V2
Secondary
Furnace, welding etc.
N1
6. Radio-transformers. It is used in radio N2
engineering etc.
0.71d
(a) (b)
Primary and Primary and
secondary secondary
coils coils
0.90d
0.70d
0.85d
0.42d
0.53d
Fig. 12.57. Core-type transformer.
0.42d
0.53d
Core 0.70d
0.85d
Low voltage insulation 0.90d
Low voltage winding
(c) (d)
High voltage insulation
High voltage winding
0.92d
0.78d
0.60d
0.36d
Fig. 12.58. Cross-section of core-type transformer.
Fig. 12.59 shows the coils and laminations of a core-
type transformer with a cruciform core and circular coils.
0.36d
0.60d
0.78d
0.92d
(e)
requirements towards allowing higher temperature will putting extra insulation between layers in addition to
drastically shorten the service life of the transformer. insulation of conductors.
3. The winding should be mechanically stable in (iii) Continuous disc winding. This type of
respect to the forces appearing when sudden short circuit winding consists of a number of flat strips wound spirally
of the transformer occurs. from inside (radially) outwards. The conductor is used in
4. The winding should have the necessary electrical such lengths as are sufficient for complete winding or
strength in respect to over voltages. section of winding between tappings. The conductor can
The different types of winding are classified and either be a single strip or a number of strips in parallel,
briefly discussed below : wound on the flat. This gives a robust construction for each
1. Concentric Windings : disc. The discs are wound on insulating cylinders spaced
(i) Cross-over (ii) Helical from it by strips along the length of cylinder. The discs are
separated from each other with press board sectors
(iii) Disc.
attached to the vertical strips. The vertical and horizontal
2. Sandwich Windings : spacers provide ducts for free circulation of oil which is in
Concentric windings. Refer to Fig. 12.64. These contact with every turn.
windings are used for core type transformers. Each limb is Sandwich coils. Sandwich coils (Fig. 12.65) are
wound with a group of coils consisting of both primary and employed in transformers of shell type. Both high and low
secondary turns which may be concentric cylinders. The voltage windings are split into a number of sections. Each
l.v. winding is placed next to the core and h.v. winding on high voltage section lies between the low voltage sections.
the outside. But the two windings can be subdivided and
interlaced with high tension and low tension section Core
alternately to reduce leakage reactance. These windings
can be further divided as follows :
(i) Cross-over windings. Cross-over windings are
used for currents up to 20 A and so they are suitable for h.v. l.v.
winding of small transformers. The conductors are either h.v.
cotton covered round wires or strips insulated with paper. l.v.
Core h.v.
l.v.
l.v. l.v.
h.v. h.v.
Fig. 12.65. Sandwich coils.
The advantage of sandwich coils is that their leakage
can be easily controlled and so any desired value of leakage
reactance can be had by the division of windings.
12.3.7.2. Terminals and leads
Fig. 12.64. Concentric coils.
The connection to the windings are of insulated copper rods
Cross-over coils are wound over formers and each coil or bars. The shape and size of leads is important in high
consists of a number of layers with a number of turns per voltage transformers owing to dielectric stress and corona
layer. The complete winding consists of a number of coils which are caused at bends and corners. Connections from
connected in series. Two ends of each coil are brought out, windings are directly taken to the busbars in the case of
one from inside and one from outside. This inside end of a air-cooled transformers while they are taken to insulated
coil is connected to the outside end of the adjacent coil. bushings in the case of coiled-cooled transformers.
(ii) Helical winding. A helical winding consists of 12.3.7.3. Tappings
rectangular strips wound in the form of a helix. The strips In a supply network the voltage can be controlled by
are wound in parallel radially and each turn occupies the changing the transformation ratio. This can be done by
total radial depth of winding. tapping the winding in order to alter the number of turns.
Helical coils are well suited for l.v. windings of large The change in number of turns may be effected when the
transformers. They can also be used for h.v. windings by transformer is out of circuit (known as off load tap changing)
596 POWER PLANT ENGINEERING
or when on load (known as on load lap changing). The Dry Type Transformers. Small transformers upto
tappings are provided on the high voltage winding because 25 kVA size are of the dry type and have the following
a fine voltage variation is obtained owing to large number cooling arrangements :
of turns. It is difficult to obtain voltage variation within
(i) Air natural. In this method the natural
close percentage limits in low voltage winding as there are
circulation of surrounding air is utilized to carry away the
few turns and voltage per turn is a large percentage of the
total voltage. heat generated by losses. A sheet metal enclosure protects
the winding from mechanical injury.
In transformers, the tappings can be provided at :
(i) phase ends ; and (ii) Air blast. Here the transformer is cooled by a
continuous blast of cool air forced through the core and
(ii) neutral point or in the middle of the windings.
windings (Fig. 12.66). The blast is produced by a fan. The
— The advantage of providing tappings at phase
air supply must be filtered to prevent accumulation of dust
ends is that the number of bushing insulators
in ventilating ducts.
is reduced, this is important where the cover
space is limited. Some transformers have
reinforced insulation at the phase ends. It is
essential that in such cases either the tapping
should not be provided at end turns or the
reinforcement should be carried beyond the
lower tap.
Coils
Core
— When the tappings are made at the neutral point
the insulation between various parts is small.
This arrangement is economical especially in the
case of high voltage transformers.
12.3.7.4. Bushings
Fan
The bushings are employed for insulating and bringing out
terminals of the winding from the container to the external Fig. 12.66
circuit. For low-voltage transformers this is accomplished
by employing bushings of porcelain around the conductor Oil Immersed Type Transformers. In general
at the point of entry. For high voltages it is necessary to most transformers are of oil immersed types. The oil
employ bushings of larger sizes. In modern transformers provides better insulation than air and it is a better
the problem is met by using large porcelain or composition conductor of heat than air. Mineral oil is used for this
bushings for voltages as high as 33 kV, above that oil filled purpose.
or condenser type bushings are used. Oil immersed transformers are classified as follows :
To 3-phase line 86.6 per cent of the balanced load factor. Another important
point to note is that, except, for a balanced unity power
factor load, the two transformers in the V-V bank operate
at different power factors.
Uses of V-V connection
(i) The V-V circuit is frequently used for two auto-
transformers. Here advantage is taken of power handling
of auto-transformers and their superior voltage regulation
and efficiency.
(ii) Another major use of V-V transformer banks is
in A.C. motor starting.
Scott or T-T connection. The connection of one
polyphase system into another polyphase system is possible
To load by suitably connecting the windings of transformers. One
Fig. 12.73. The V-V (open ) connection of transformers. of the early types that was used is Scott or T-T connection,
by which a 2-phase system is available from a 3-phase
This type of connection is used in the following system or vice-versa.
cases : Fig. 12.74 shows two single-phase transformers M
(i) When the three-phase load is comparatively and T, the primaries of which are connected to a 3-phase
small so that the installation does not warrant a three supply. The secondary of M forms one phase and the
transformer bank. secondary of T the other phase of a true 2-phase system. M
(ii) When one of the transformers in a - bank fails, is called the main transformer and T is called the teaser.
so that the service may be continued until the faulty One end of the teaser primary is connected to the mid-
transformer is repaired or a good one is substituted. point of the main primary. The two ends of the main
(iii) When it is anticipated that the future load will primary are connected to two lines wires of a 3-phase,
increase to warrant the chosing of the open at some time 3-wire system, and the third line wire is connected to a
later. tapping X on the teaser primary.
V-V connection has a number of features that are L
advantageous.
Teaser (T)
— Upon failure of the primary or secondary of one X
transformer of a complete - transformer R Phase-II
circuit, the system reverts to a V-V circuit, so
this is an automatic stand by. The power-
N M
1
handling capacity of a V-V circuit is times
3 B Main transformer (M) Y
the capacity of a full - of the same
transformers. This feature works both ways, so
a circuit is sometimes installed as V-V with the Phase-I
understanding that its power handling may be
multiplied by 3 by adding one more Fig. 12.74. Scott or T-T connection.
transformer. If the supply voltages are assumed symmetrical, the
— Open delta or V-V circuits do introduce some triangle of voltages is equilateral as shown in Fig. 12.75.
voltage unbalance due to the non-symmetry of
3
the voltage regulation effects under load. The vertical line LS = NM, so that it gives the
However, the small degree of unbalance is not 2
relationship between the number of turns of two primaries,
normally noticed by a motor load or other types
as
of commercial load.
Number of turns for the main transformer M 100
Disadvantages of V-V connection
Number of turns for the teaser T 86.6
1. The secondary terminal voltages tend to become Hence, if two identical single-phase transformers
unbalanced to a great extent when the load is increased, are to be used for Scott-connection, the primary one must
this happens even when the load is perfectly balanced. have a tapping point brought out from its mid-point of the
2. The average factor at which the V-bank operates primary, and the second transformer must have a tapping
is less than that of the load. This power factor is actually X brought out from 86.6% of its primary turns.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 601
L
the main primary and 21 the current of the
teaser primary. Hence op and oq are the line
currents. Below is the proof that ol = om = on,
and that each one of these currents is at 120°
from the other two.
n IR
f
N S M
f
Fig. 12.75 m l
1 f O 1
I I
2 R 2 R
R
q p
IR IB IY
Fig. 12.78
Load
n
m
1
IB IY on
2
q
B
Load
Y O f
l
Fig. 12.76
1
on
As the two-phase side is asymmetrical, there cannot 2
be perfect balanced conditions on the three-phase side. p
However, neglecting the impedance of the windings, it can
be shown that if load on the 2-phase side is balanced the Fig. 12.79
3-phase side is also balanced (Figs. 12.76, 12.77 and 12.78).
Proof. Let us assume that the ratio of turns of the
— Fig. 12.76 shows the connection diagram. The
main transformer be 100 : 100 (primary to secondary) and
2-phase side has equal load impedances.
that of teaser 86.6 : 100. If the secondary load-currents are
100 A at unity power factor, the primary balancing amperes
n IR
of the main transformer will be 100 and lie along ml. The
100
teaser balancing amperes will be × 100 = 115.4 and
86.6
will lie along on. The teaser primary current splits into
m O l half at 0 and flows in the two halves of the main primary.
1 1 Hence the line current in Y and B is given by
LM(100) F 115.4 I OP
I I
2 R 2 R 2
q p
MN
2
GH 2 JK P since these two components are at
Q
IB IY
Fig. 12.77
LM(100) F 115.4 I OP
2 1/2
— In Fig. 12.77, the vector diagram is drawn for
unity power factor load. The secondary currents
right angles to each other. Now
MN
2
GH 2 JK PQ
are not shown. On is the teaser primary current,
= 115.4 A and the angle between ol and op is such that
and since it flows at the mid-point of the main
transformer, it divides itself equally in two 57.7
= tan–1 = 30° (Fig. 12.77). Hence op lags on by 90° + 30°
halves. The resultant current in the lines B and 100
Y is the vector sum of the balancing amperes of = 120°. Q.E.D.
602 POWER PLANT ENGINEERING
— In Fig. 12.78, the vector diagram is drawn for a cores which have the same maximum value, but differ in
condition when the load power factor is cos . time phase by 120°. In the common leg of the three cores of
The same proof can be applied to this case as Fig. 12.81, the three fluxes add, and the net flux is therefore
was done for the case of unity power factor. If always zero. The common leg may then be eliminated, with
the loads are unbalanced and have different a subsequent saving in core material and size of
power factors, such as cos 1, and cos 2, primary transformer. A single polyphase transformer would be of
side becomes unbalanced. The vector diagram impractical construction if it were the same as Fig. 12.80
of Fig. 12.79 shows the extent of unbalanced with the centre leg omitted. Instead, the core-type
when the teaser load is of unity power factor polyphase transformer is manufactured so that it looks
and the main transformer load has a power
factor of cos (lag).
Yoke III
12.3.9.2. Three-phase transformer construction
— The windings of three single-phase transformers
can be wound on a common core. The advantages
and disadvantages are given below :
Window
Advantages :
1. One 3-phase transformer is cheaper than three
single-phase transformers.
Limbs
2. It has slightly better efficiency and regulation. I
3. A 3-phase transformer takes less floor space. II
On the other hand, from the point of view of stand
by, or same capacity, it is economical to have 3 single-phase Fig. 12.80. Core-type transformers for polyphase
transformers plus one spare rather than two 3-phase transformation.
transformers one of which is a spare. However, in large
central stations 3-phase transformers are often
L M N
advantageous.
Disadvantages :
1. Three-phase transformers are much more difficult
and costly to repair than are single-phase units.
2. When failure does occur and it becomes necessary
to substitute a replacement unit to maintain service, the
cost of spare is much greater than it would be were a single- Fig. 12.81. Core-type three-phase transformer.
phase transformer to be used as a replacement in a three- like that shown in Fig. 12.81. Actually, what we have done
transformer bank. is, that axes of three coils have been moved into one plane.
3. There is a difficulty in transporting a heavier This causes the magnetic reluctance of coil M to differ
three-phase transformer compared with the moving of each somewhat from that of L and N. This produces a slight
of the three single-phase transformers. unbalance in the three magnetizing currents, but the effect
— Two general kinds of three-phase transformers is not serious, especially under load.
are recognized, similar to single-phase Three-phase shell type transformer
transformers, depending upon the relative
— In Fig. 12.82 are shown three shell-type
arrangements of windings and cores. These are
transformers stacked one above the other, with
the core type and the shell type.
only the primary coils shown.
Three-phase core type transformer. Fig. 12.80
— In Fig. 12.82 (a) the three coils are wound in
shows three core-type transformers placed together so that
the same direction. The flux in the common core
they have a common path for the return magnetic circuit.
area between adjacent phases such as the
Although the windows should be entirely filled by primary
shaded portions is thus equal to the difference
and secondary coils on each of the legs, only primary coils
of two of the phase fluxes. Since the fluxes are
are shown on the outside legs. This simplifies the diagram,
120° apart in time, this mutual flux is equal to
while it in no way changes the actual theory that follows,
since the primary coils set up the flux. If the three 3 × ( 21 ), or 0.866 of the flux in the centre leg.
transformers are identical in all respects, a balanced three- If the same flux density is maintained
phase system of voltages will produce three fluxes in the throughout, less iron is required in the common
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 603
leg. Now, however if the centre coil, phase M is — The calculations are made for one phase only.
reversed, the flux in the common core is equal The value of equivalent impedance used is the
to the sum of the fluxes of two adjacent phases. equivalent impedance per phase referred to
This is shown in Fig. 12.82 (b). As in any three- secondary.
phase system, the sum of two fluxes is equal to — When the impedances of primary and secondary
either flux alone, which in this case is 0.5 . This windings are given separately, then primary
represents a further saving in iron, and for this impedance must be transferred to secondary by
reason shell-type three-phase transformers are multiplying it with (transformation ratio)2.
usually wound with centre coil opposing the two — In case of Y/ or /Y transformers the voltage
outside ones. ratios as given in the questions, refer to terminal
voltages and are quite different from turn ratio.
f
12.3.10. Instrument Transformers
L It is not practicable to connect instruments and meters
1f
2 directly to the lines in high voltage circuits. Instead
1f instrument transformers are used. The following are the
M 2 two basic advantages inherent in this method :
(i) Standard rated instruments may be used.
(ii) Operating personnel coming in contact with the
N instruments are not subject to high voltage and current of
the lines, and so there is less danger to them. Even with a
low-voltage system, instrument transformers are used for
(a) measuring large currents, so that heavy leads to the
instrument panel and to the ammeter and other current
terminals are avoided.
The principle of the instrument transformer is
L fundamentally the same as that of the power transformer.
The instrument transformers are classified as follows :
1. Potential transformers.
M 2. Current transformers.
12.3.10.1. Potential transformers (P.T.)
— A potential transformer is a step down
N
transformer used along with a low range
voltmeter for measuring a high voltage. The
primary is connected across the high voltage
(b)
supply and the secondary to the voltmeter or
Fig. 12.82. Shell-type three-phase transformer (a) coil M
potential coil of the wattmeter. Since the
wound in the same direction, (b) coil M wound in opposite voltmeter (or potential coil) impedance is very
direction. high, the secondary current is very small and
the potential transformer behaves as an
12.3.9.3. Parallel operation of 3-phase transformers ordinary two winding transformer operating on
The conditions for paralleling 3-phase transformers are no-load. Fig. 12.83 shows a potential trans-
same as that required for parallel operation of single-phase former used to measure the voltage of a circuit.
transformer with the following additions : It may be noted that the secondary is grounded.
This is done so that if the insulation breaks
(i) The voltage ratio must refer to the terminal down, the high voltage does not endanger
voltage of primary and secondary. personnel who may be reading the meters.
(ii) The phase displacement between primary and
— These transformers are made with high quantity
secondary voltages must be the same for all transformers
iron core operating at very low flux densities so
which are to be paralleled.
that the magnetising current may be very small.
(iii) The phase sequence must be the same. Careful design ensures minimum variation of
Following points are worth noting while dealing with voltage ratio with load and minimum phase shift
3-phase transformers : between input and output voltages. Potential
604 POWER PLANT ENGINEERING
Current
transformer Line
Current carrying
conductor A
Potential
transformer
V
12.3.11. Constant Current Transformers — The rating is usually given in kW, and the
secondary current. The standard values of
A constant-current transformer is used for supplying power
current are 6.6, 7.5 and 20 A. The load power
to street lights which are connected in series. The primary
factor is almost 100%. The regulation is
of this transformer receives power at constant voltage and
expressed as the percentage of the current
varying current and the secondary supplies power at
(secondary) from its rated value. The regulation
constant current and varying voltage, which depends upon
should not exceed 1%.
the number of lamps in series.
Principle of operation. The principle of operation
of a constant-current transformer is illustrated in
12.4. SWITCHGEAR
Fig. 12.87. The switchgear constitutes all parts or equipments of the
— One coil is stationary while the other one is power plant whose function is to receive and distribute
movable, and its weight is partly balanced by a electric power. It comprises of the following :
counter-weight W. Either coil may be the (i) Assemblies of switching apparatus
movable coil. (ii) Protective and indicating metering devices
— The openings through the coils are much longer
(iii) Interconnecting bus bar systems and relevant
than the core. This permits a large leakage flux
accessories.
to be set up through the coils when the currents
are maintained in them. 12.4.1. Functions of a Switchgear
— It is clear from Fig. 12.87 that a mechanical force The functions performed by a switchgear are listed below :
of repulsion exists between the coils. This force
1. To localise the effects of faults by operation of
tends to drive the movable coil upward on the
protective equipment and so automatically disconnect
core, and owing to the counter weight, a
faulty plant from the system.
relatively small force produces motion. At
maximum load the movable coil is close to the 2. To break efficiently short circuits without giving
stationary one and the voltage induced in the rise to dangerous conditions.
former is a maximum. When the secondary load 3. To facilitate redistribution of loads, inspection and
is reduced by cutting out some of the lamps in maintenance on the system.
the series circuit, the current in the remaining
units increases momentarily. This cause the
12.4.2. Switches
force of repulsion to increase. The floating coil The most important types of switches fall in one of the
then moves upward and thereby increases the following classes :
equivalent leakage reactance of the transformer, (i) Knife switches (ii) Disconnecting switches
reduces the secondary voltage, and brings the (iii) Air-break switches (iv) Control switches
current back to normal. The coil comes to rest
(v) Auxiliary switches (vi) Oil switches
when the terminal voltage is properly reduced
to suit the lesser number of lamps and the current (vii) Magnet impulse switches.
attains its correct constant value. (i) Knife switches. These switches are used to
open and close circuit of low voltage and current capacity.
They are extensively used in lighting and small power
circuits. In order to protect such low capacity circuits
against overloads and short circuits, it is necessary that
proper fuses be connected in series with the switch blades.
(ii) Disconnecting switches. For power circuits it
is necessary to use some type of circuit breaker to open or
Counter
W
weight
close the circuit. In order to isolate the circuit breakers it
is generally considered good practice to connect knife
f2 f f2 switches in series with the circuit breakers. Such knife
Movable switches are known as disconnecting switches. They should
+ never be opened until the circuit breaker in the same circuit
secondary
Secondary f1 f1 coil has been opened, and should always be closed before the
core circuit breaker is closed. They are not designed to break
+
Stationary currents and should therefore, never, be opened while
primary current is flowing in the line.
coil (iii) Air-break switches. By “air-break” switches
Fig. 12.87. Constant-current transformer. are meant switches designed to open circuits under load.
606 POWER PLANT ENGINEERING
They are generally used outdoors for circuits of medium copper caps which are fastened to each end of the casing.
capacity, such as lines supplying an industrial load from a Fuses of general type are available for circuits upto about
main transmission line or feeder. In order to take of the 25000 volts. There are on the market a large number of
arc that occurs on opening such a switch, special arcing fuses of the general type, the particular details of
horns are provided, so that the arc may rise and be construction being very varied. They are used as a
ruptured. Air-break switches are built for about 135,000 protective device in low-capacity circuits, such as small
volts maximum but their use is in general confined to lower lighting and power lines, and on the secondary of
voltages. These switches are not designed to operate under instrument-potential transformers, when used for metering
abnormal conditions, such as short circuits. or relay protection.
(iv) Control switches. Under this class are included Fig. 12.88 shows a HRC—cartridge type fuse. HRC
all the switches that are used to control the operation of stands for high-rupturing-capacity. In its simplest form it
other equipment. As a general rule, they are designed for consists of a heat resisting ceramic body having metal
operating voltages less than 250 volts and very small (brass) end caps to which are welded fusible silver
current capacities. (or bimetallic) current carrying elements. The complete
(v) Auxiliary switches. Under this class are space within the body surrounding the elements is filled
included all switches or contractors that are actuated by with a powder, usually quartz, which acts as an arc
some other control switch or device. In the control of power extinguishing agent.
equipment, such as circuit breakers, it is impracticable to When the fuse is carrying normal rated current, the
handle the operating current through the control switches temperature of the fuse element does not reach melting
on the switch-board, hence an auxiliary operating switch point. On occurrence of a fault short circuit current flows
is placed near the circuit breaker, this switch being through the fuse element and the fuse element melts before
electrically operated by a control switch that may be located the fault current reaches its first peak. As the heat is
at any desired distance from the circuit breaker. Thus, the produced, the melted fuse element will vapourize. The
control circuits may be designed for very small currents, chemical reaction between silver vapour and filling powder
while the operating circuits as a general rule must handle tends to establish the high resistance. The high resistance
much large currents and very often at higher voltages. acts as an insulator because the fault current decreases
(vi) Oil switches. For certain applications at high along with the high pressure created within the fuse by
voltages and large current capacities it is desirable to the fault (excessive) current. Thereafter a transient voltage
immerse the switch contacts under oil. The effect of the oil is created at the instant of fault current interruption on
is to cool and quench the arc that tends to form when the account of sudden release of energy.
circuit is broken.
Bi-metal thermal
(vii) Magnet impulse switches. In this type of
Brass end cap control
switch the arc is extinguished by blowing it magnetically Fuse link contact
into arc chutes where it is lengthened, cooled, and
interrupted. The magnetic effect is produced by the circuit
current which is passed through suitable coils, setting up
a strong magnetic field across the space between the switch
contacts as they are opened. The basic principle involved
in lengthening the arc is that of a simple motor, in which
force is directly proportional to the product of magnetic Filling powder Fuse element Outer element
flux and current.
Cartridge
12.4.3. Fuses
Fig. 12.88. High rupturing capacity catridge fuse.
Fuses are used to protect circuits of small capacity against
abnormal currents such as overloads or short-circuits. 2. Transformer fuse block and cut-out. The
There is a large variety of fuses on the market, but proper protection of distribution circuits has for years been
the most important types that are used for power purposes recognized as best fulfilled by means of fuses. Distribution
are : transformers are as a general rule placed on poles, towers,
1. Cartridge fuses or in manholes and any automatic protection would be
entirely too complicated and expensive. Fuses offer a simple
2. Transformer fuse blocks
and cheap method of protection. It is common practice to
3. Expulsion fuses. place these fuses in the secondary of such transformers,
1. Cartridge fuses. These fuses are composed of a thereby protecting the transformers against short circuits
strong fibre casing inside of which is enclosed a fuse wire, or overloads. There are two types of fuses that are generally
generally an alloy of lead. The fuse voice is fastened to used for the purpose. Both types include a porcelain
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 607
housing, enclosing the fuse and contact points. In one type 12.4.4.3. Classification of circuit breakers
the fuse is carried on a plug that is provided with an Circuit breakers may be classified as follows :
insulating porcelain knob in order that it may be removed
1. Low voltage circuit breakers
for re-using. A second type consists of a rectangular
porcelain receptacle with a removable front door that 2. High voltage circuit breakers
carries the fuse. (a) Oil circuit breakers
3. Expulsion fuse. For higher voltages such as (i) Bulk oil circuit breakers
found in power circuits or main feeders, there is often a (ii) Low oil contact circuit breakers
demand for a fuse, on account of its simplicity. The (b) Oil-less circuit breakers
expulsion-type fuse has been developed for such service. (i) Air blast circuit breakers
This device consists of a hollow tube, made of some (ii) Water circuit breakers
heat resisting substance such as fiber with a lining of
(iii) Hard gas circuit breakers.
asbestos or some other material, through which is passed
a fuse wire. One end of the tube is closed and connected to Characteristics of High Voltage Rating Circuit
the line, the other end is opened and allows the fuse wire Breakers
to project out and connect to the other terminal. When a The high voltage rating circuit breakers should
short circuit or overload occurs, the fuse is blown and a possess the following characteristics :
certain amount of gases form inside the tube. These gases
1. They should have high reliability-electrically and
in escaping to the air cause the arc, which is generally
mechanically.
produced, to be blown out. Since there is always a tendency
for an arc to occur, these fuses are adaptable only to outdoor 2. They should be capable of interrupting inductive
use. They may be obtained for practically any modern and capacitive circuits and fault currents of all values
transmission line voltage. within their rating.
3. The opening i.e., the time interval between receipt
12.4.4. Circuit Breakers of tripping impulse and contact separation should be the
There is probably no other part of a power system that is minimum mechanically possible.
more important than the equipment that controls the Oil circuit breakers (O.C.B.)
system. All the control devices discussed above are suitable These are the most common type of circuit breakers
for only relatively small capacities, but for large capacities used in power stations. The rating range of these circuit
it is necessary to employ more dependable means of control, breakers lies between 25 MVA at 2.5 kV and 5000 MVA at
such as is obtained by the use of circuit breakers. 250 kV. The advantages of using oil as a quenching
12.4.4.1. Function of a circuit breaker medium are :
1. It has high dielectric strength.
The function of a circuit breaker is to break a circuit when
various abnormal conditions arise and create a danger for 2. It absorbs arc energy while decomposing.
the electrical equipment in an installation. The heaviest 3. Good cooling property of gas formed (as a result
duty a circuit-breaker has to perform is to interrupt a short- of decomposition of oil).
circuit current which may reach a value of several tens of 4. Surrounding oil in close proximity to the arc
thousands and even more (> 105 amperes) in a large presents a large cooling surface.
capacity power system. At the same time, in order to quickly 5. It acts as an insulator between live part and earth.
eliminate the source of the fault, the circuit-breaker must 6. The ability of cool oil of high dielectric strength
open the circuit with least possible delay. to flow into the arc space after the current is zero.
12.4.4.2. Principle of circuit breaker Disadvantages :
The breaking of circuit means rapid conversion of 1. It is easily inflammable.
predetermined section of circuit from a conductor to 2. It can cause explosion by mixing with air.
insulator. When the current carrying contacts are 3. It requires maintenance and periodic replace-
separated, an arc (which contains an ionized gas) is ment.
produced between them. This arc provides for the gradual Plain break oil circuit breaker :
change-over from current carrying to voltage isolating Fig. 12.89 shows the arrangement of this breaker.
states of the contacts. Therefore, it plays an important part There is a strong weather tight earthed metal tank,
in circuit interruption process. The arc has to be carefully containing oil upto a predetermined level, and an air
controlled because a good deal of energy in the form of heat cushion above the oil. The oil pressure is this breaker tank
is generated in it. The produced arc may be extinguished is solely due to the head of oil above the contacts which are
by high resistance or low resistance methods. enclosed in the tank.
608 POWER PLANT ENGINEERING
To operate Advantages :
mechanism An air circuit breaker claims the following
advantages over oil-circuit breaker :
1. Fire hazards due to oil are eliminated.
Air cushion
2. Operation takes place quickly.
Vent
3. There is less burning of contacts since arc duration
Oil level is short and consistent.
4. Facility of high speed re-closure.
Fixed contacts 5. Suitable for frequent operation (since the cooling
Movable contacts medium is replaced constantly).
Limitations
1. Sensitivity to restriking voltage.
2. Current chopping.
3. A compressor is constantly required to remain in
Fig. 12.89. Plain oil circuit breaker. operation.
When the contacts separate an arc is struck. This 4. The leakage of air at the pipe line fittings creates
vaporizes oil into gas. The sudden formation of the gas by problems.
arc may dissipate heat generated as a result of arc.
Water circuit breaker
The major drawback of this breaker that it suffers
The principle of the water circuit breaker is shown
from the defect of permitting rather long and inconsistent
in Fig. 12.91. The contacts are in water, which is turned
arcing times. In view of this limitation, such circuit breakers
into steam by the arc and rushes past the opening to blow
are suitable only for low current and low voltage operations
out the arc.
not exceeding 150 MVA at 11 kV.
Air circuit breakers :
In air circuit breakers the compressed air at Fixed contact
pressure around 15 kgf/cm2 is used for extinction of arc.
Fig. 12.90 shows a typical air-blast circuit breaker. The
extinction of arc is caused by flow of air around the moving
circuit. The breaker is closed by applying pressure at the Moving contacts
lower opening, and opened by applying pressure at the
upper opening. When the contacts separate, the cold air
rushes round the movable contact and blows out the arc.
Air pressure
for opening
Plunger
Water
receptacle
Air pressure
for closing
3. The individual units should be so designed that (iii) To prevent operating mistakes simple and
the risks of failure are reduced to minimum. efficient interlocks can be installed.
4. Fire protection arrangement must be made (iv) Erection on the site can be easily carried out.
adequately.
(v) Since it occupies less space, therefore, building
5. To keep the breaking duty within the capacity of cost in reduced.
the circuit breakers reactors should be used where
5. Outdoor switchgear. The following points are
necessary.
worthnoting :
12.4.5. Types of Switchgear (i) Although it requires large ground space but
The various types of switchgear are enumerated and there is a saving in building cost.
discussed below : (ii) Maintenance work is at the mercy of the
1. Cellular 2. Cubicle weather.
3. Truck 4. Metal clad (iii) The damage from lightning is likely to be more
5. Outdoor switchgear. since the equipment is exposed.
1. Cellular. The components of this type of (iv) Frequent insulation cleaning.
switchgear are enclosed in cells made of brick, concrete or (v) As compared to an indoor switchgear its
moulded stone. These components can be easily inspected maintenance cost is more.
and modifications can be made without any difficulty. The
cellular type gear has the following disadvantages : 12.5. PROTECTION OF ELECTRICAL
(i) The erection of a cellular type gear is a lengthy SYSTEMS
process.
(ii) It occupies large space. 12.5.1. General Aspects
(iii) The interlocking systems may be complicated. Fig. 12.92 shows a typical power system. In such a power
2. Cubicle. The whole of the equipment, in this case, system the function of relays and circuit breakers is to
is enclosed in steel plate cubicles with complete or partial prevent or limit damage to the system due to faults or
sub-dividing barriers. It entails the following advantages : overloads and to isolate the faulty section from the
(i) It requires relatively small floor area. remainder of the system.
(ii) It presents a neat and simple layout. The function of the relay system is to recognize the
3. Truck. In this type of switchgear a movable truck fault and to initiate the operation of devices or circuit
carries the circuit breaker moving isolator contacts, and breakers to isolate the defective element with the minimum
the potential and current transformers. The front panel of disturbance to the service.
the truck fits into the stationary steel cubicle which houses Typical system protective zones are shown in
the busbars, cable box, and fixed isolator contacts. When Fig. 12.92. These zones might be classified as :
inspection is to be carried out, the truck is withdrawn from (i) Generators (ii) Low-tension busses
the cubicle. (iii) Transformers (iv) High-tension busses
4. Metal clad. Here all conductors and insulators
(v) High-tension transmission lines
are enclosed by an earthed metal case. A metal clad
switchgear is of two types : (vi) Feeders.
(i) Horizontal draw out The speed with which relays and circuit breakers
operate has a direct bearing on :
(ii) Vertical drop down.
(i) The quality of service to consumers
A metal clad switch gear has the following
advantages : (ii) The stability of the system
(i) As all the live parts are enclosed in metal it (iii) The amount of power that may be transmitted
ensures safety to operators and reduces maintenance without exceeding the stability limit
charges. (iv) The damage done by a short circuit and
(ii) Maintenance work can be easily carried out consequently the cost and delay in making repairs
(since working parts are easily and safely accessible). (v) Safety to life and property.
610 POWER PLANT ENGINEERING
Feeder
Transformer
Generators Lines
The successful operation of the modern power 12.5.2. Different Types of Relays
system is to a great extent due to the modern high-speed
All relays are essentially composed of three elements :
circuit breakers.
(i) An actuating element
Relays have been developed for practically all types
of system disorders, which may be listed as follows : (ii) A movable element
1. Rotating machines (iii) A set of contacts.
(i) Short-circuits in machine Relays may be classified as follows :
(ii) Open circuits in machine 1. According to their time action
(iii) Over current (i) Instantaneous (ii) Definite time limit
(iv) Overheating (iii) Inverse time.
(v) Motoring of generator 2. According to their mechanical details or
principle of action
(vi) Loss of field
(i) Plunger type (ii) Induction type.
(vii) Over speed
3. According to their application
(viii) Bearing over heating
(i) Current relays (ii) Directional relays
(ix) Single-phase and unbalanced current operation.
(iii) Voltage relays (iv) Auxiliary relays
2. Transformers
(v) Differential relays
(i) Short-circuits
(vi) Distance or impedance relays.
(ii) Open circuits
Requirements of relay
(iii) Overloads.
1. Definite operation with accuracy
3. Busses. Bus failures are somewhat remote
compared with failures in other parts of a system. An 2. Selective operation
insulator support may fail, producing a line-to-ground fault, 3. Flexibility
or in remote cases a bus-to-bus short-circuit may occur. 4. Sensitivity.
4. Transmission lines. Transmission and distri- Description of Commonly used Relays
bution lines, because of their length and exposed nature, 1. Plunger type relay. Refer to Fig. 12.93. It
are the source of most trouble. Several causes may imitate consists of a core or plunger which is movable within a
trouble, such as : (i) overloads and (ii) any type of short solenoid. When sufficient amount of current is passed
circuit, caused by the breaking of the conductors or falling through the winding, the core is pulled up, thus causing
trees etc. the cone-shaped disc at the top to bridge the gap between
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 611
stationary contacts. The position of the plunger with respect 3. Current balance relays. This type of relay is
to coil is adjustable ; the lower its position, the more current commonly used. It operates on the principle of current
is required to pull it into the closing position, and by balance in which two currents are compared on a
adjusting its position it may be set to take any proportionate basis. The principle of this type of relay is
predetermined value of current within the range of the coil. shown in Fig. 12.95.
Cover
Stationary contacts
Beam
Movable contact
Insulating base Restraint Operating
coil coil
Solenoid coil
Fig. 12.95. Current balance relay.
4. Differential relays. As the name implies, these
relays depend for their operation on the difference in
Plunger currents that might flow in two parts of a system. In the
Fig. 12.96 is shown an elementary circuit diagram of a
standard differential relay. It is composed of three windings,
Lock out the two outside ones being known as the restraining coils
and the inner one as the operating coil. They are so made
and connected that the two restraining coils exert a
Adjustment device
downward pull, while the operating coil exerts an upward
pull on the armature. In Fig. 12.96 is shown how the three
Fig. 12.93. Plunger type relay. windings, are connected.
2. The Over-current (Induction type) relay. Coils ‘a’ and ‘b’ are connected to their respective
This type of relay is shown in Fig. 12.94. The output of the current transformers in the power circuit so that under
current transformer is supplied to the winding on the normal conditions the sum of the current through them in
central part of E shaped core. The second winding from zero, and hence the operating coil ‘c’ will not exert any force
this place is connected to two windings on poles of the U- upon the moving mechanism. When the difference in the
shaped core. The disc is mounted in between the cores. It current in the two lines protected becomes great enough to
carries contacts and is free to rotate against a mechanical overcome the weaker of the two retaining windings, the
restraining torque. Currents are induced in the disc due to moving contact mechanism will rise and throw to one side,
the magnetic flux across the air gaps. Flux is also produced thereby completing the circuit of the trip coil of the oil circuit
by the lower magnet. The combined effect produces a breaker.
rotational torque. The speed of the disc is controlled by
using brake magnet. The operation line varies inversely
a, b = Restraining coils
with the current supplied to the relay by the current c = Operating coil
transformer.
To current
Line A
Line B
transformer
b c a
Upper
electromagnet
Brake magnet
Metal
disc.
Lower electromagnet
Fig. 12.94. Induction type over-current relay. Fig. 12.96. Differential relay.
612 POWER PLANT ENGINEERING
Instantaneous
hand reset relays
± D.C. bus
Current transformers
Current transformers
Generator
b
Fig. 12.97. Overload protection for alternators.
Bus
oil circuit
breaker
Restraining
coils
coil
Current
percentage
differential
relay
Polarity r-4
marks b re ake
y at ker
-3
f rela
Time o a t b r ea
ay
of rel ker
-2 r-1
S Time t brea r e ake
Time S Time a tb
ea
Generator S Tim
4 3 2 1
Bus Fault
oil circuit Distance Oil circuit
breakers breaker
Current Fig. 12.102
transformers Overcurrent or
harmonic restraint relay Distance protection. For line to ground faults, the
simple overcurrent protection is probably more satisfactory
(c) Schematic one-line diagram of than distance protection. However, for phase to phase faults,
current-differential protection of
buses using over current relay. the distance protection is applicable, since the circuit
impedance is quite constant and not subjected to seasonal
Fig. 12.101 changes, as is the case with earth impedances.
Fig. 12.103 illustrates the application of this method
12.5.6. Protection of Transmission Lines of protection to a radial system.
The requirements of line protection can be summarised as
follows : Time of relay at breaker
1. In the event of a short circuit the circuit breakers 5 4 3
Time
nearest the fault should open, all other circuit breakers
remaining in a closed position. 2
2. In case the nearest breaker to the fault should Generator
not open fast enough, back up protection should be secured 5 4 3 2 1
from adjacent circuit breakers.
Distance Fault
3. Line circuit breakers should not trip due to loss
of synchronism or hunting of generators. Fig. 12.103
4. The relay time should be just as short as possible Pilot wire protection. In the case of a short line
in order to preserve system stability, without unnecessary it is possible to obtain very positive protection by the
tripping of circuits. so-called “pilot wire” method. The method is essentially
Common Methods of Line Protection Against differential protection applied to the transmission lines.
Short-Circuits Current transformers are placed in each phase at both ends
of the line and connected by means of pilot wires, as shown
1. Overcurrent protection.
in Fig. 12.104. Only one phase is shown in order not to
2. Distance or impedance protection. obscure the fundamental principle involved. It is evident
3. Pilot protection and carrier current protection. from the above diagram that this is identical in its principle
4. Balanced current or balanced power protection. of operation with the differential protection applied to
alternators. A short circuit at any point between the current
Some of the above methods are discussed below :
transformers will cause the oil circuit breakers at both ends
Overcurrent protection. This type of protection of the line to open. The relays used may be of either the
is the most elementary type of line protection available. It induction or plunger type but probably the induction
generally employs the induction-type inverse-time relay. inverse-time relay is the most common for this type of
Fig. 12.102 illustrates such an application to a radial installation. The natural objection to pilot wires is in the
system involving one generating station and four fact that they are likely to be broken or damaged. The
substations. The relay-time settings are adjusted so that expense of placing pilot wires on the transmission towers
the first circuit breaker to trip in the event of a fault, is the should also be considered. In the case of long lines in which
one nearest the fault. The selectivity between substations the capacity effect is appreciable, this method of protection
is obtained by the time interval ‘S’. cannot be used.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 615
Turbine
Reactors house
(iii) Should be free from draughts. (i) Linear (ii) Horse shoe shaped
(iv) There should be no glare. (iii) Semi-circular.
(v) The colour schemes should be soothing to eyes. The house shoe shaped and semicircular control
boards occupy more floor space but they enable all the
(vi) The instruments should have clear scales instruments to be seen from one point.
properly calibrated.
In some cases, the control boards are of desk type in
(vii) All the apparatus and circuits should be labelled which the control and indicating equipment are located on
so that they are clearly visible. the front, and the relays and integrating instruments are
Control boards. These are of the following three placed behind.
forms : Fig. 12.110 shows the layout of a control room.
Metering equipment
Alternator board
Governor alarm
Relay board
Synchronising
swing frame
Relay board
In case the sources of power are two or more in In solid earthing, a direct metallic connection is
number then the neutrals of these sources should be made from the system neutral to one or more earth
earthed to ensure having a neutral earthed in the event electrodes consisting of plates, rods or pipes buried in or
one of the sources is out of service. driven into the ground, generally in a bed of coke below
The earthing of high voltage neutral is mainly done the permanent water level. Where permanently moist
to protect the system while the low voltage neutral is ground cannot be ensured a supply of water should be made
earthed chiefly in order to reduce the possible danger to available so that the periodic watering cannot be done. The
human life. value of contact resistance or resistance of the earthing
Where energy is transformed suitable provision system should be as small as possible and this should be
should be made to protect the lower voltage system from checked from time to time. Now-a-days the term ‘solidly
becoming charged above its normal voltage by leakage or earthed’ has been replaced by the term ‘Effectively earthed’.
electrostatic induction from the higher voltage. A transformer neutral may be ‘solidly earthed’ in
that there may be no impedance between the neutral and
Methods of Earthing System Neutral earth. However, the transformer capacity thus solidly
1. Solid earthing 2. Resistance earthing earthed may be too small in comparison with the sizes of
3. Reactance earthing 4. Resonant earthing. the system to be effective in stabilizing the voltage from
phases to ground when the fault takes place.
Solid earthing :
Resistance earthing :
When the neutral of a generator or power
The neutral of the generator is connected to the
transformer or earthing transformer is connected direct to
earth through a resistor as shown in Fig. 12.112. The
the earth, as shown in Fig. 12.111 (a) (b) the system is
resistance introduced in this case acts as a current limiting
solidly earthed. Solid earthing is generally used on low
device. The resistors used in this case may be metallic
voltage circuits, 600 volts or less, and on most circuits above
carbon powder or liquid type. The magnitude of the
15 kV. In the range of 2.2 to 15 kV any of the remaining
resistance to be used should be such that it should limit
three types may be used.
the earth fault current to a value which will reduce
To earthwire
minimum damage at the point of faults.
The advantages of resistance earthing are listed
Soil Concrete below :
surface cover 1. The ground faults are readily relayed.
2. The hazards of arcing grounds are minimized.
Insulated
conductor 3. The mechanical stresses in the circuit carrying
fault currents are reduced.
Bitumen Earthenware
filling pipe 4. Least inductive influence on neighbouring
communication.
5. Electric shock hazards to the persons, caused by
stay-earth fault currents in the earth return path, are
Metal pipe reduced.
6. Line voltage drop, caused by the occurrence of
earth fault, is reduced.
The main disadvantage of resistance earthing is that
(a) is costlier than the solidly earthed system.
Y
Y
Xg
Xg Rm
(b)
Y G G G G G G
CB CB CB CB CB CB
S S S S S S
CB CB CB CB CB CB
Xg Xm T T T T T T
Reactance earthing :
In this case a reactor is connected between the S S S S S S
neutral of the machine and earth as shown in the
CB CB CB CB CB CB
Fig. 12.113. Sometimes a low reactance is connected in
series with the neutral of the machine to limit the earth
To transmission lines
fault current through the generator. This current should
not be greater than the 3-phase fault current of the Fig. 12.114. Single busbar system.
generator. The earth-fault-current of this system should
not be less than 25% of the 3-phase fault current in order 2. Double busbar system :
to minimize the transient voltages. In the Fig. 12.115 illustrated a double busbar
system. In this system both low voltage and high busbars
12.9. ELECTRICAL EQUIPMENT-LAYOUT are duplicated, any one of the busbar sections can be used
as desired. There is a provision of a busbar coupling switch
In a power station the layout of electrical equipment for transferring operation from one busbar to another.
consists of the following : The advantage of this system is that it is possible to
(i) Busbars’ arrangement (at generator voltage) have one bus bar “live” and to carry out repairs on the other
(ii) Circuit breakers and switches’ arrangement when required.
3. Ring busbar system : by excitation ; but the reactive kVA can be changed. The
Refer to Fig. 12.116. In this arrangement two circuit sharing of the load, off course, is determined by the
breakers serve one line. This system has the advantage regulation of the governor of the prime movers.
that there are always two parallel paths to the circuit and 2. Tap changing transformers. In this case the
failure of one section does not interrupt the service variation of voltage is achieved by having a number of
completely. tappings on the secondary winding so that turn-ratio can
be changed as per requirement. It can be done either
Line manually or automatically depending upon the specific
application and requirements.
3. Booster transformer. Booster transformers are
S S installed immediately before the load where regulation is
CB CB required. This booster system has the following advantages:
(i) It is independent of the main transformer so that
S S
a failure in the former will not throw the later out of service
S S S S for any length of time.
(ii) It is much cheaper method when there is no main
CB CB
transformer at the point where regulation is desired.
S S
Some other methods of regulation are :
S (i) Phase angle control
Line (ii) Use of induction regulator, and
(iii) Voltage control by power factor.
Fig. 12.116. Ring busbar system.
of the network of a power system which distributes power 5. Voltage : 115/230, 550, 1100, 2200, 6600, 11000,
for local use. 12000, 13200, 32000 V.
Distribution systems may be classified as follows :
12.11.6. Underground Cables
1. Nature of current
(i) Direct current Underground cables consist of one or more conductors
properly insulated, all surrounded by a lead sheath, which
(a) Two wire (b) Three wire
excludes air and moisture and also acts as a protecting
(ii) Alternating current. cover.
2. Method of connections Cables for underground service may be classified
(i) Series as follows :
(a) Open loop (b) Parallel loop 1. Number of conductors
(c) Combination of open and parallel loops (i) Single conductor (ii) Multiconductor
(ii) Multiple 2. Arrangement of conductors
(a) Three system (b) Feeder and main
(i) Single (ii) Sector
(c) Network (d) Loop system
(iii) Concentric
(e) Ring system.
3. Number of phases
3. Number of phases
(i) Single phase (ii) Polyphase
(i) Single
(a) Two wire (b) Three wire 4. Type of insulation
(ii) Two (i) Rubber (ii) Varnished cambric
(a) Three wire (b) Four wire (iii) Oiled paper (iv) Graded
(c) Five wire (v) Oil filled
(iii) Three 5. Special features, split conductor
(a) Three wire (b) Four wire (i) Concentric (ii) D-shaped
4. Mounting Fig. 12.121 shows the different types of underground
(i) Overhead (ii) Underground cables.
Lead sheath
Copper strands
(a) Single conductor (b) Two conductor (c) Three conductor (d) Four conductor
Insulating material
(e) Sector-type three (f) Two conductor (g) Three concentric (h) Three D-shaped
conductor concentric split conductor split conductor
substations in a town it is possible to lay the distributors, 12.13. INDIAN ELECTRICITY ACT
at a lower cost.
2. Foundation mounted substations Some extracts of the Indian Electricity Act, 1910, are given
below :
Such substations are built entirely in the open and
all the equipment is assembled into one unit usually Definitions. (i) Area of supply. Area of supply
enclosed by a fence from the point of view of safety. means the area within which alone licensee is for the time
being authorised by his licence to supply energy.
Substations for primary and secondary transmission
(ii) Consumer. Consumer means any person who is
and for secondary distribution (above 300 kVA) are
supplied with energy by a licensee or the Government or
foundation mounted outdoor type. Since equipment
by any other person engaged in the business of supplying
required for such substations is heavy, therefore, site
energy to the public under this Act or any other law for the
selected for these substations must have a good access for
time being in force, and includes any person whose premises
heavy transport. are for the time being connected for the purpose of receiving
The switch gear consists of circuit breakers of energy with the works of a licensee, the Government or
suitable type on both the sides but with the increased such other person, as the case may be.
reliability of the modern transformers, the practice is to (iii) Distributing main. Distributing main means the
dispense with the circuit breaker on the incoming side from portion of any main with which a service line is, or is
the economic consideration. The isolating switches thus intended to be, immediately connected.
serve the purpose. (iv) Electric supply line. Electric supply line means
While selecting the sites for such substations the a wire, conductor or other means used for conveying,
following factors should be given due considerations : transmitting or distributing energy, whether by overhead
1. Nearness to the load centres of distribution areas. line or underground cable, together with any casing,
2. Availability of land. coating, covering, tube, pipe or insulator enclosing,
surrounding or support the same or any part thereof, or
3. Cost of land.
any apparatus connected therewith for the purpose of so
4. Local zoning laws. conveying, transmitting or distributing such energy and
5. Future load growth. includes any support, cross-arm, stay, strut or safety device
Advantages of outdoor substations over indoor erected or set up for that purpose.
substations : (v) Energy. Energy means electrical energy—
1. Fault location is easier since all the equipment is (a) generated, transmitted or supplied for any
within view. purpose, or
2. The time required to erect such substations is (b) used for any purpose except the transmission of
less. a message.
3. The extension of the installation is easier. (vi) Mains. Mains means any electric supply line
4. The smaller amount of building material is through which energy is, or is intended to be, supplied to
required. the public.
5. Switch gear installation cost is low. (vii) Service line. Service line means any electric
supply line through which energy is, or is intended to be,
Disadvantages :
supplied :
1. More space required.
(a) to a single consumer either from a distributing
2. The various switching operations with the main or immediately from the supplier’s
isolators, as well as supervision and maintenance of the premises, or
apparatus is to be performed in the open air during all (b) from a distributing main to a group of consumers
kinds of weather. on the same premises or on adjoining premises,
3. The influence of rapid fluctuation in ambient supplied from the same point of distributing
temperature and dust and dirt deposits upon the outdoor main.
substation equipment makes it necessary to install (viii) Works. Works includes electric supply line and
apparatus specially designed for outdoor service and, any building, plant, machinery, apparatus and any other
therefore, more costly. thing of whatever description required to supply energy to
the public and to carry into effect the objects of a licence or
Note. Not-withstanding the disadvantages, outdoor sanction granted under this Act or any other law for the
substations are very widely used in power system. time being in force.
626 POWER PLANT ENGINEERING
Criminal Offences and Procedure of any such meter, indicator or apparatus or prevents any
1. Theft of energy. Whoever dishonestly abstracts, such meter, indicator or apparatus, from duly registering ;
consumes or uses any energy shall be deemed to have or
committed theft within the meaning of theft under I.P.C. (d) improperly uses the energy of a licensee, shall
45 and the existence of artificial means for such be punishable with fine which may extend to ` 500 and in
abstractions shall be prime facie evidence of such dishonest the case of continuing offence, with a daily fine which may
abstraction. extend to ` 50 ; and if it is proved that any artificial means
2. Penalty for unauthorised supply of energy exists for making such connection as is referred to in clause
by non-licensees. Whoever, in contravention of the (a) or for causing alteration or prevention as is referred to
provisions of the Act engages in the business of supplying in clause (c) or for facilitating such improper use as referred
energy, shall be punishable with fine which may extend to to in clause (d), and that the meter, indicator or apparatus
` 30000 and in the case of a continuing contravention, with under the custody or the control of the consumer, whether
a daily fine which may extend to ` 300. it is his property or not, it shall be presumed, until the
contrary is proved, that such connection, communication,
3. Penalty for illegal or defective supply or for
alteration, prevention or improper use, as the case may
non-compliance with order. Whoever: (a) being a
be, has been knowingly or wilfully caused by such
licensee or a person who has obtained the sanction of the
consumer.
State Govt. to engage in the business of supplying energy
to the public, save as permitted under relevant sections or 6. Penalty for negligently wasting energy or
by his licence or as the case may be by the conditions of injuring works. Whoever negligently causes energy to
sanction, supplies energy or lays down or places any electric be wasted or diverted, or negligently breaks, throws down
supply line or works outside the area of supply ; or or damages any electric supply line, post, pole or lamp or
other apparatus connected with the supply of energy
(b) being a licensee or a person who has obtained
connected shall be punishable with fine which may extend
the sanction of the State Govt. as aforesaid in contravention
to ` 200.
of the provisions of this Act or if the rules thereunder, or in
breach of the conditions of licence or the sanction, as the 7. Penalties for offences not otherwise
case may be, and without reasonable excuse, the burden of provided for. Whoever, in any case, not provided for by
proving which shall lie on him, discontinues the supply of above sections makes default in complying with any of the
energy or fails to supply energy ; above provisions of the Act, or with any order issued under
it, or, in the case of a licensee, with any of the conditions of
(c) makes default in complying with any of the
the licence, shall be punishable with fine which may extend
provisions of an order or of any notice or requisition issued ;
to ` 100 and, in the case of a continuing default, with a
(d) makes default in complying with any directions
daily fine which may extend to ` 20.
issued to him shall be punishable with fine which may
8. Offences by companies. (i) If any person
extend to ` 1000, and, in the case of continuing offence or
committing an offence under this Act is a company, every
default, with a daily fine which may extend to ` 100.
person who at the time the offence was committed was in
4. Penalty for illegals transmission or use of
charge of, and was responsible to the company for the
energy. Whoever, in contravention of the provisions,
conduct of the business of the company, as well as the
transmits or used energy without giving the notice required
company, shall be deemed to the guilty of the offence and
thereby, shall be punishable with fine which may extend
shall be liable to be proceeded against and punished
to ` 500 and, in the case of a continuing offence, with a
accordingly ;
daily fine which may extend to ` 50.
Provided that nothing contained in this sub-section
5. Penalty for interference with meters or
shall render any such person liable to any punishment, if
licensees works and for improper use of energy.
he proves that the offence was committed without his
Whoever:
knowledge or that he exercised all due deligence to prevent
(a) connects any meter or indicator or apparatus the commission of such offence.
with any electric supply line through which energy is
(ii) Notwithstanding anything contained in sub-
supplied by a licensee, or disconnects the same from any
section (1), where an offence under this Act has been
such electric supply line ;
committed with the consent or connivance of, or is
(b) lays, or causes to be laid, or connects up any attributable to, any neglect on the part of any director or
works for the purpose of communicating with any other manager, secretary or other officer of the company, such
works belonging to a licensee ; or directors, manager, secretary or officer of the company shall
(c) maliciously injures any meter or any indicator also be deemed to be guilty of that offence and shall be
or apparatus or wilfully, or fraudulently alters the index liable to be proceeded against and punished accordingly.
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 627
HIGHLIGHTS
1. Some of the important equipments available in a power (iv) Primary and secondary open
plant are : (v) Primary T—secondary T (Scott connection).
(i) Generators (ii) Exciters 9. The switch gear constitutes all parts or equipments of the
(iii) Transformers (iv) Reactors power plant whose function is to receive and distribute
(v) Circuit breakers electric power. It comprises of the following :
(vi) Switchgear and protective equipment (i) Assemblies of switching apparatus
(vii) Control board and equipment (ii) Protective and indicating metering devices
(viii) Busbars (iii) Interconnecting busbar systems and relevant
accessories.
(ix) Stand by generators.
10. Types of Switches :
2. An electrical generator is a machine which converts
(i) Knife switches (ii) Disconnecting switches
mechanical energy (or power) in electrical energy (or
power). The basic essential parts of an electrical generator (iii) Air-break switches (iv) Control switches
are : (v) Auxiliary switches (vi) Oil switches
(i) Magnetic field (vii) Magnet impulse switches.
(ii) A conductor/conductors which can so move to cut the 11. Fuses are used to protect circuits of small capacity against
flux. abnormal currents such as overloads or short-circuits.
3. The three important characteristics of D.C. generators The most important types of fuses that are used for power
are : purposes are :
1. No load saturation characteristics (E0/If) (i) Cartridge fuses (ii) Transformer fuse blocks
2. Internal or total characteristics (E/Ia) (iii) Expulsion fuses.
12. The function of a circuit breaker is to break a circuit when
3. External characteristics (V/I).
various abnormal conditions arise and create a danger
4. A machine for generating alternating currents is referred for the electrical equipment in any installation. The circuit
to an alternator. Alternators, according to their breakers are classified as follows :
construction, are divided into the following two
1. Low voltage circuit breakers
classifications :
2. High voltage circuit breakers
1. Revolving armature type
(a) Oil circuit breakers
2. Revolving field type.
(i) Bulk oil circuit breakers
5. The following methods are used to cool the alternators :
(ii) Low oil contact circuit breakers.
1. Open system using air
(b) Oil-less circuit breakers
2. Closed system using air
(i) Air blast circuit breakers
3. Hydrogen cooling. (ii) Water circuit breakers
6. The function of a transformer is to transform alternating (iii) Hard gas circuit breakers.
current energy from one voltage into another voltage. The
13. Types of switch gears :
transformer has no rotating parts, hence it is often called
(i) Cellular (ii) Cubicle
a static transformer.
(iii) Truck (iv) Metal clad
7. Kinds of transformers :
(v) Outdoor switch gear.
(i) Power transformers
14. The function of the relay system is to recognize the fault
(ii) Auto-transformers
and to initiate the operation of devices or circuit breakers
(iii) Transformer for feed installations with static to isolate the defective element with the minimum
converters. disturbance to the service.
(iv) Testing transformers Relays may be classified as follows :
(v) Power transformers for special applications 1. According to their time action
(vi) Radio-transformers. (i) Instantaneous (ii) Definite time limit
8. Three phase transformer connections : (iii) Inverse time.
(i) Primary Y—secondary Y 2. According to their mechanical details or principle
(ii) Primary —secondary of action
(iii) Primary —secondary Y, or vice versa (i) Plunger type (ii) Induction type.
628 POWER PLANT ENGINEERING
3. According to their application The following systems are used for layout of electrical
(i) Current relays (ii) Directional relays equipment :
(iii) Voltage relays (iv) Auxiliary relays 1. Single busbar system.
(v) Differential relays
2. Double busbar system.
(vi) Distance or impedance relays.
3. Ring busbar system.
15. Methods of earthing system neutral :
(i) Solid earthing (ii) Resistance earthing 17. Transmission lines may be classified as follows :
(iii) Reactance earthing (iv) Resonant earthing. (i) Single line (ii) Parallel lines
16. In a power station the layout of electrical equipment (iii) Radial lines (iv) Ring system
consists of the following :
(v) Network.
(i) Busbars’ arrangement (at generator voltage).
(ii) Circuit breakers and switches’ arrangement 18. The substations serve as sources of energy supply for local
(iii) Transformers’ location areas of distribution in which these are located.
(iv) Controlling switch board arrangement. Outdoor substations are very widely used in power system.
THEORETICAL QUESTIONS
1. Give the classification of generating equipment. 21. State the function of a relay system.
2. Explain the working principle of a ‘generator’. 22. How are relays classified ?
3. Enumerate and explain briefly the characteristics of D.C. 23. Explain briefly any two of the following relays :
generators.
(i) Plunger type relay
4. State the application of D.C. generators.
(ii) Over-current relay
5. Explain the working principle of an ‘alternator’.
(iii) Differential relay.
6. What is an exciter ?
24. Explain briefly the methods of protecting alternators
7. Write short note on A.C. exciters.
against damage due to excess current due to short-circuit.
8. Explain the alternator synchronising procedure.
25. Explain briefly how the following is materialised.
9. Enumerate and explain briefly different methods of cooling
of alternators. (i) Transformer protection
10. What is a transformer ? How are transformers classified ? (ii) Bus protection
11. What are the advantages and disadvantages of the (iii) Protection of transmission lines.
following three-phase transformer connections : 26. What is a short-circuit ? What are the effects of short-
(i) The Y—Y connection circuits ?
(ii) The Y— connection 27. What are the functions of a reactor ?
(iii) The V—V connection. 28. Give the layout of a control room.
12. How are three-phase transformers classified ? 29. Enumerate the methods of earthing system neutral.
13. What do you mean by a ‘switch gear’ ? Explain with a neat sketch the ‘solid earthing’ system.
14. What are the functions of a switch gear ? 30. Write a short note on transmission and distribution of
15. Enumerate important types of switches. electric power.
16. What is a fuse ? How are fuses classified ? 31. Explain briefly the following in regard to overhead
17. Explain with the help of a neat sketch the construction transmission lines :
and working of a high rupturing capacity cartridge (i) Line supports
(H.R.C.) fuse. (ii) Conductor material
18. What is a circuit breaker ? (iii) Insulators.
19. How are circuit breakers classified ? 32. How are cables (for underground service) classified ?
20. Explain briefly any one of the circuit breakers :
33. What are the advantages of underground power
(i) Oil circuit breaker transmission systems ?
(ii) Air circuit breaker 34. What are the advantages of over-head power transmission
(iii) Water circuit breaker. systems ?
MAJOR ELECTRICAL EQUIPMENT IN POWER PLANTS 629
1. (a) What is the function of circuit breaker ? Name the (c) Control board equipments.
different types of circuit breakers. Explain in detail 5. (a) What are the different methods of earthing a power
with the help of neat diagrams oil circuit breakers. system ? Explain in detail.
(b) Explain the various methods of controlling the voltage (b) What are the different methods used for generator
at the consumer terminal used in power supply system. cooling ? Explain in detail.
2. (a) What is the necessity of generator cooling ? What 6. (a) What type of dust collector is used in super thermal
methods are used for generator cooling ? power plant ? Why is it preferred to other types ?
(b) What is the function of circuit breakers in a power (b) How would you justify the combined working of power
supply system ? Explain the different types of circuit plants ?
breakers.
(c) Define ‘Hydrograph’ and explain its importance in the
3. (a) Write criteria for optimum loading of a power plant design of storage of hydroelectric power project.
and economic loading of combined thermal and hydro-
(d) Draw a neat sketch showing essential parts of a power
plants.
transformer.
(b) Write the factors which affect economies of generation
7. (a) Define rating of a transformer.
and distribution of power.
(b) Show the most commonly used connections for three-
4. Write briefly on the following :
phase voltage transformation with schematic
(a) Earthing of a power station ; diagrams. State the merits and demerits of each.
(b) Protective equipments ; (c) Explain parallel operation of transformers.
Pollution and Its Control 13
13.1. Introduction. 13.2. Pollution from thermal power plants—Gaseous emission and its control—Particulate emission and its
control—Solid waste disposal—Thermal pollution. 13.3. Pollution from nuclear power plants. 13.4. Pollution from hydro-electric
power plants and solar power generating stations—Highlights—Theoretical Questions.
13.1. INTRODUCTION unwanted gases and particles into the atmosphere while
the heat is thrown into the atmosphere and rivers. Both
All power production plants, invariably, pollute the these aspects pollute the environment beyond tolerable
atmosphere and the resulting imbalance on Ecology has a limits and now are being controlled by appropriate
bad effect. The pollution is inevitable in some cases and regulations. The types of emissions, effects and methods
has to be minimised to the extent possible. This is being of minimising these pollutions are discussed below.
achieved by effective legislations all over the world.
The air pollution in a large measure is caused by
The power plant pollutants of major concern are:
the thermal power plants burning conventional fuels (coal,
A. From fossil power plants
oil or gas). The combustible elements of the fuel are
(i) Sulphur oxide (ii) Nitrogen oxides converted to gaseous products and non-combustible
(iii) Carbon oxide (iv) Thermal pollution elements to ash. Thus the emission can be classified as
(v) Particulate matter. follow:
B. From nuclear power plants 1. Gaseous emission
(i) Radioactivity release
2. Particulate emission
(ii) Radioactive wastes
3. Solid waste emission
(iii) Thermal pollution.
Besides this, pollutants such as lead and 4. Thermal pollution (or waste heat).
hydrocarbons are contributed by automobiles.
13.2.1. Gaseous Emission and Its Control
In this chapter, we shall look at the type of pollutions
various power plants cause and the method of minimising The various gaseous pollutants are:
these bad effects. (i) Sulphur dioxide
(ii) Hydrogen sulphide
13.2. POLLUTION FROM THERMAL (iii) Oxides of nitrogen
POWER PLANTS (iv) Carbon monoxide etc.
The environment is polluted to a great extent by thermal The effects of pollutants on environment are as
power plants. The emission from the chimney throws follows :
630
POLLUTION AND ITS CONTROL 631
Effects
S. No. Pollutant
On man On vegetation On materials/animals
3. H2S Bare disease, respiratory diseases Destruction of crops Flourosis in cattle grazing
Removal of sulphur dioxide (SO2) — The wet scrubbers also find application in
SO2 is removed by wet scrubbers as shown in chemical and grain milling industries.
Fig. 13.1. — The collection efficiency of scrubber is about
90 per cent.
Cleaned gas
The following are disadvantages of using wet
scrubbers :
Straightening
vanes 1. The gases are cooled to such an extent that they
must be reheated before being sent to the stack.
2. The pressure drops are very high.
3. Water used, after dissolving sulphur oxides will
contain sulphuric and sulphurous acids which may corrode
the pipelines and the scrubber itself. This water cannot be
Core buster let out into the rivers for obvious reasons.
disc In power plants where high sulphur content coal is
the only source available, it is preferable to remove the
Spray manifold
sulphur from the coal before it is burnt. This is done by
Tangential gas coal washing which reduces the fly-ash as well as some
inlet sulphur oxides in the flue gases. But the power plants
Swinging inlet employ “Flue-gas desulphurization” (FGD) system
damper
similar to wet scrubber system. FGD can be of the following
types :
1. The recovery or regenerative system
Dirty
gas 2. Throw away or non-regenerative system. In this
inlet system the reactants are not recovered and the final
Water outlet Water inlet products are sulphur salts of calcium and magnesium.
Regenerative System
Fig. 13.1. Wet scrubber. Some of the regenerative systems are :
— The gases to be cleaned are admitted 1. FW-Bergbau process
tangentially into the scrubber which will also 2. Wellman-Lord process
help in separating the particulate matters. 3. Wet magnesium oxide process.
Water spray absorbs these gases and particulate — In the Fig. 13.2 is shown the FW-Bergbau
matters which collect on the surface of the process. In this process, SO2 is removed by
scrubber are washed down by the water and this absorption and sulphur is collected as molten
water is further treated, filtered and reused. sulphur.
VED
p-plant (color)\plan13-1 IInd 27-02-15 3rd 11-03-15 4th 15-06-15
632 POWER PLANT ENGINEERING
To chimney
Hot sand char Resox
regenerator SO2 reactor
Coal
SO2 Recycle gas to
Boiler char absorber
char Clean flue SO2
flue gas
absorber gas saturated
char To char To molten sulphur
Screen absorber storage tank
To bottom
ash disposal
To flyash
disposal
VED
p-plant (color)\plan13-1 IInd 27-02-15 3rd 11-03-15 4th 15-06-15
POLLUTION AND ITS CONTROL 633
Cinders. These are ash particles of diameters of as shown. These are commonly used in stoker
100 microns or more. and small cyclone furnaces where crushed coal
The above particulates, in any system of controlling is burned rather than the very fine pulverised
the particulate emission, are to be effectively collected from coal. The collection efficiencies of cinder catchers
the flue gases. The performance parameters for any are from 50 to 75%.
particulate remover is called the collection efficiency defined
as: — Refer to Fig. 13.7. Cinder-vane fan. The cinder
vane fan uses the fan which imparts centrifugal
Mass of dust removed
Collector efficiency = × 100 force to the particulates and they are collected
Mass of dust present
as shown. The efficiency is from 50 to 75%.
For different systems the collector efficiency varies
from 50 to 99%; for an electrostatic precipitator it is move
than 90%.
Some collector systems, their efficiencies and their
adaptability, are discussed in the following paragraphs.
13.2.2.1. Cinder catchers
The cinder catchers are shown in Figs. 13.4 to 13.7.
— Refer to Fig. 13.4. Sudden decreases in gas Fig. 13.7. Cinder-vane fan.
velocity makes the particulates separate and
fall. 13.2.2.2. Wet scrubbers
— Refer to Fig. 13.5. A sudden change in the — Wet scrubbers as described for removal of gases
direction of flow of flue gas throws the
can also be used for removal of particulate
particulates away and can be collected.
matters ; but the gases will have to be reheated
before they are sent to the stack.
— The wet scrubbers are not commonly used to
remove particulate matters.
13.2.2.3. Electrostatic precipitator
— An electrostatic precipitator is shown in
Fig. 13.8. In this device a very high voltage of
Fig. 13.4. Sudden decrease in gas velocity.
30 kV to 60 kV is applied to the wires suspended
in a gas-flow passage between two grounded
plates.
High voltage
electrode
Collector plates
VED
p-plant (color)\plan13-1 IInd 27-02-15 3rd 11-03-15 4th 15-06-15
634 POWER PLANT ENGINEERING
VED
p-plant (color)\plan13-1 IInd 27-02-15 3rd 11-03-15 4th 15-06-15
POLLUTION AND ITS CONTROL 635
1. Construction of a separate lake. A sufficiently chemical method. If the waste is discharged in the
large water storage in the form of a lake can be built and atmosphere, air and water will be contaminated beyond
once-through cooling the condenser can be adopted. If the the tolerable limits. Some methods of storage or disposal
natural cooling of water from the lake is not sufficient, of radioactive waste materials are discussed below :
floating spray pumps can be employed. 1. Storage tanks. The radioactive wastes can be
This method improves the thermal efficiency of the buried underground (very deep below the surface) in
plant but can prove expensive. Also, it may not always be corrosion resistance tanks located in isolated areas. With
possible to have a large enough lake artificially built. the passage of time these will become stable isotopes.
2. Cooling pond. A cooling pond with continuously 2. Dilution. After storing for a short time, low
operating fountains can be adopted for smaller power energy wastes are diluted either in liquid or gaseous
plants. This will also serve as a beautifying feature of the materials. After dilution, they are disposed off in sewer
power plant site. without causing hazard.
3. Cooling towers. In order to throw heat into the 3. Sea disposal. This dilution can be used by
atmosphere most power stations adopt the cooling towers. adequately diluting the wastes and this method is being
The hyperbolic shape given to the tower automatically used by the British.
induces air from the bottom to flow upwards and the water 4. Atmospheric dilution. This method can be used
is cooled by coming in direct contact with the air. This is a for gaseous radioactive wastes. But solid particles from the
natural convection cooling and is also called ‘wet-cooling gaseous wastes must be filtered out thoroughly since they
tower’. The overall efficiency of such plants will be lower are the most dangerous with higher half lives.
than those of the plants adopting once-through cooling 5. Absorption by the soil. Fission products are
system. There will be considerable vapour flumes escaping disposed off by this method. The radioactive particles are
from the cooling towers. Sometime, make-up cooling water absorbed by the soil particles. But this is expensive.
may be scarce. In such cases, dry cooling tower can be
6. Burying is sea. Solid nuclear wastes can be
adopted. Dry cooling towers are much more expensive than
stored is concrete blocks which are burried in the sea. This
wet cooling towers.
method is expensive but no further care is needed.
All cooling towers, whether dry or wet, are expensive
and add to the initial investment of the plant. Small plants
can adopt mechanical-draft systems using induced or forced
13.4. POLLUTION FROM HYDRO-ELECTRIC
draft systems. This helps in avoiding height to the cooling POWER PLANTS AND SOLAR POWER
towers. Thus, the initial cost is reduced but the GENERATING STATIONS
maintenance cost of mechanical-draft systems are high.
Hydro-electric and Solar Power Generation plants have no
13.3. POLLUTION FROM NUCLEAR polluting effect on the environment. The hydro-electric
project does not pollute the atmosphere at all, but it can be
POWER PLANTS argued that the solar power stations in the long run may
The various types of pollution from nuclear power plants upset the balance in nature. To extend the argument to
are : the logical end, imagine a very vast area of land is covered
(i) Radioactive pollution by solar collectors of different forms. Then the minimum
required sun’s rays may not reach the earth’s surface. This
(ii) Waste from reactor (solid, liquid, gases)
will certainly kill the vegetation on the earth and also the
(iii) Thermal pollution. bacteria which are destroyed by sun’s rays may survive
(i) Radioactive pollution. This is the most giving rise to new types of health problems. Further, the
dangerous and serious type of pollution. This is due to evaporation of water and consequent rains may change
radioactive elements and fissionable products in reactor. their cycles. Added to these, the average temperatures of
The best way to abate is the radioactive shield around the the earth and ocean may change. This may result in new
reactor. balances among the living creatures which cannot be easily
(ii) Waste from reactor. Due to nuclear reactor predicted. Since we do not envisage such a large scale
reaction nuclear wastes (mixtures of various Beta and coverage of earth’s surface in the near future, we can safely
Gamma emitting radioactive isotopes with various half state that the solar energy power plants do not pollute the
lives) are produced which cannot be neutralised by any atmosphere.
VED
p-plant (color)\plan13-1 IInd 27-02-15 3rd 11-03-15 4th 15-06-15
636 POWER PLANT ENGINEERING
HIGHLIGHTS
1. The power plant pollutants of major concern are : (iii) Solid waste emission
(a) From fossil power plants : (iv) Thermal pollution (or waste heat).
(i) Sulphur oxide 3. Thermal discharge index (TDI) of any power plant is the
(ii) Nitrogen oxide number of thermal energy units discharged to the
environment for every unit of electrical energy generated.
(iii) Carbon oxide
4. Thermal pollution can be reduced by :
(iv) Thermal pollution
(i) Constructing a separate lake
(v) Particulate matter.
(ii) Cooling pond
(b) From nuclear power plants :
(iii) Cooling towers.
(i) Radioactivity release
5. Some methods of storage or disposal of radioactive waste
(ii) Radioactive wastes materials are :
(iii) Thermal pollution. (i) Storage tanks (ii) Dilution
2. The emission may be classified as follows : (iii) Burial (iv) Sea disposal
(i) Gaseous emission (v) Atmospheric dilution (vi) Absorption by soil
(ii) Particulate emission (vii) Burying in sea (viii) Projecting into space.
THEORETICAL QUESTIONS
1. Name some power plant pollutants of major concern. 8. Where are ‘Baghouse filters’ used ?
2. How are emissions from thermal power plants classified ? 9. What do you mean by ‘Thermal Pollution’ ?
3. Name important gaseous pollutants discharged by
10. What is ‘Thermal Discharge Index’ (TDI) ?
thermal power plants. How are they controlled ?
4. Describe briefly, with the help of a neat diagram, ‘wet- 11. Enumerate and explain briefly various methods of
scrubber’ used for removing SO2. reducing the thermal pollution.
5. What is ‘Particulate emission’ ? How is it controlled ? 12. Write a short note on ‘Pollution from Nuclear power
6. Define the following : plants’.
Smoke, Fumes, Fly-ash, Cinders. 13. What are the various methods of storage or disposal of
7. What is an electrostatic precipitator ? radioactive waste materials ?
VED
p-plant (color)\plan13-1 IInd 27-02-15 3rd 11-03-15 4th 15-06-15
‘GATE’ and ‘UPSC’
14
Examinations’ Questions
(Latest-Selected) with
Answers/Solutions
(A) Conventional Questions with Answers/Solutions
(B) Multiple-choice Questions with Answers and ‘‘Explanations’’
Q.14.1. (Nuclear power plant): The overall are 87%, 98% and 99% respectively. The boiler uses
thermal efficiency of a 5 MW nuclear power plant for a pulverized coal having a calorific value of 26 MJ/kg and
submarine is 30%. Calculate the amount of natural yields 92% efficiency. The feedwater passing through the
uranium, U235, needed to generate the power if the average feed heaters enters the boiler at 160°C. The risers of the
energy release per fission for U235 is 190 MeV. Take 1 W = furnace are 55 m high while the downcomers are placed
6.241 × 1012 MeV/s. Avogadro’s Number is 6.02 × 1023. outside the furnace for producing natural circulation. The
quality of steam at the top of the riser is 12% and a minimum
(IES)
exit velocity of mixture leaving the risers and entering the
Solution. Given: Power output = 5 MW; Efficiency, drum is 1.4 m/s. The dimensions of the riser tubes are
= 30%; Energy released by each atom of U235 = 190 MeV; 60 mm OD and 3 mm wall thickness while the dimensions
1 W = 6.241 × 1012 MeV/s; Avogadro’s number = 6.02 × 1023. of downcomers are 185 mm OD and 8 mm thick. Assume
Mass of U235 needed, m: no pressure drop and heat loss to the risers. Work out the
following:
2QYGTQWVRWV
Power produced = (i) Show the process on T-s diagram.
(ii) The generation of rate of steam ignoring the
amount of steam bled off to feed heaters in kg/s.
= = 16.67 × 106 W
(iii) The rate of fuel flow required in kg/s.
= 16.67 × 106 × (6.241 × 1012)
(iv) The evaporation factor.
= 1.04 × 1020 MeV
(v) The circulation ratio.
Number of U235 atoms required to this amount of
(vi) The number of riser tubes.
energy,
(vii) The number of downcomers.
N= = 5.47 × 1017 Take the following properties:
h1 = 3448.6 kJ/kg
Hence, the mass which contains 5.47 × 107 atoms
h2 = 1987 kJ/kg
= hf3 = 137.8 kJ/kg
hf5 = 675.5 kJ/kg
= 2.135 × 10–4 gm (Ans.)
riser, top = 396 kg/m3
Q. 14.2. (Steam power plant): A steam power plant
generating 500 MW of electrical power employs a natural downcomer, inlet = 603 kg/m3
circulation boiler which supplies steam at a pressure of 150 where suffixes 1, 2, 3 and 5 denote boiler exit (or turbine
bars and temperature of 550°C. The condenser pressure is inlet), condenser exit, pump inlet and boiler inlet
0.05 bar. The turbine, mechanical and generator efficiencies respectively. (IES)
637
638 POWER PLANT ENGINEERING
(i) Fig. 14.2 shows the process on T-s diagram. 9VWTDKPG 9EQORTGUUQT
(ii) Cycle thermal efficiency, thermal: Hence, thermal =
3U
6 ⎛R ⎞
= ⎜ ⎟ =
= 2.1678 =
6 ⎝ R ⎠
or, T2 = 288 × 2.1678 = 624.33 K = 0.7159 or 71.59% (Ans.)
6 6 (iii) Work ratio:
(isen)C = 0.86 = =
6 6 6 9VWTDKPG 9EQORTGUUQT
Work ratio =
⎛ ⎞ 9VWTDKPG
or, T 2 = ⎜ ⎟ + 288 = 679.1 K
⎝ ⎠
=
Now, p4 = p5 = = 3.87 bar
R R =
= 0.525 or 52.5% (Ans.)
6 ⎛R ⎞ 6 ⎛ ⎞ (iv) Specific power output:
Again, = ⎜ ⎟ or = ⎜ ⎟
6 ⎝ R ⎠ ⎝ ⎠ Specific power output = Net work output
or, T4 = 1086.5 K = Wturbine – Wcompressor
= 853.29 – 405.21
6 ⎛R ⎞ 6 ⎛ ⎞
Similarly, = ⎜ ⎟ = = ⎜ = 448.08 kJ/kg (Ans.)
⎟
6 ⎝ R ⎠ ⎝ ⎠ (v) Mass flow rate of air, ma:
.
or, T6 = 1018.9 K
a × Net work output =
m =
At (isen)T = 88%, we have: CNVGTPCVQT
6 6 6
0.88 = =
6 6 or, a × 448.08 =
m
or, T 4 = 1600 – 0.88 (1600 – 1086.5)
= 1148.1 K
or, a =
m
6 6 6
Again, 0.88 = = = 569.32 kg/s (Ans.)
6 6
Q.14.4. (Gas turbine plant): A two stage
or, T6 = 1500 – 0.88 (1500 – 1018.9)
compression with intercooling in between stages and a single
= 1076.6 K stage turbine with regeneration is employed in an open cycle
6 6 6 gas turbine plant. Air at 1 bar and 15°C enters the
Effective, = 0.75 = =
6 6 compressor and the maximum pressure ratio is 5 and the
or, T7 = 0.75 (1076.6 – 679.1) + 679.1 maximum temperature in the cycle is 800°C. The rate of air
flow through the cycle is 250 kg/sec and the calorific value
= 977.2 K
of the fuel used is 42 MJ/kg. The isentropic efficiencies of
Wturbine = [cp(T3 – T 4) + cp(T5 – T6)] × mech both the compressors is 0.8 and the effectiveness of the
= [1.005 (1600 – 1148.1) regenerator is 0.7, and the isentropic efficiency of the turbine
+ 1.005 (1500 – 1076.6)] × 0.97 is 0.9. The combustion efficiency is 0.95, the mechanical
efficiency is 0.96 and the generator efficiency is 0.75. Take
= 853.29 kJ/kg
cp of air = 1.005 kJ/kg K and = 1.4 and for gases cp = 1.08
E R
6 6
kJ/kg K and = 1.33.
Wcompressor = =
OGEJ Assuming perfect intercooling and neglecting
= 405.21 kJ/kg pressure and heat losses, determine:
Qsupplied, Qs = cp (T3 – T7) (i) The air fuel ratio.
= 1.005 (1600 – 977.2) (ii) The cycle efficiency.
= 625.9 kJ/kg (iii) The specific fuel consumption. (IES)
640 POWER PLANT ENGINEERING
r or, T7 = 642.9 K
ba
755 5 Work done by compressors
6¢
7 = WC(I) + WC(II)
642.9 2¢
4 4¢ 2 6 a cpa (T 2 – T1) + m
= m a cpa (T4 – T3)
r
288 1 ba = 250 × 1.005 [(380.7 – 288)
3 1
+ (381.4 – 288)]
s(kJ/kg K)
= 46757.6 kJ/s
Fig. 14.3
Net work done by compressors
C
O
(i) Air fuel ratio, :
H
O = =
OGEJ
Due to perfect intercooling,
= 48705.8 kJ/s
p2 = p3 = R R = = 2.23 bar
Heat supplied, f × C.V. × combustion
Qs = m
Since the pressure ratio and isentropic efficiency of
each compressor is same then the work input required for f × (42 × 103) × 0.95 = 39.9 × 103 m
= m f
each compressor is the same since both the compressors By energy balance equation, we have:
have the same inlet temperature (perfect intercooling), i.e.,
T1 = T3 and T 2 = T 4. Qs = ( m f )cpg T5 – m
a + m a cpa T7
For compressors: f ) × 1.08 × 1073 – 250
= (250 + m
C
× 1.005 × 642.9
6 ⎛R ⎞ C
Now, = ⎜ ⎟ or, f + 128181.4)
Qs = (1158.8 m
6 ⎝ R ⎠
6 f + 128181.4 = 39.9 × 103 m
1158.8 m f
or, =
or T2 = 362.2 K
or, f =
m
6 6 =
?
Also, (isen)C(I) =
6 6
= 3.31 kg/s
or, 0.8 = or T 2 = 380.7 K C
O
6 Hence, = = 75.53 (Ans.)
H
O
C 1.4 1
6 ⎛R ⎞ C T (ii) Cycle efficiency, cycle:
Similarly, = ⎜ ⎟ or 4 = ⎛ 5 ⎞ 1.4
6 288 ⎜ 2.23 ⎟ Wnet = Wturbine – Wcompressors
⎝ R ⎠ ⎝ ⎠
‘GATE’ AND ‘UPSC’ EXAMINATIONS’ QUESTIONS (LATEST-SELECTED) WITH ANSWERS/SOLUTIONS 641
f ) cpg(T5 – T6)
a + m
Wturbine = ( m p8 = 3.5 bar,
= (250 + 3.31) × 1.08 (1073 – 755) compressors = 82%, turbines = 85%,
= 86996.8 kW Power generated = 6000 kW,
Net work done by turbine Effectiveness, = 0.65, cpa = 1.005 kJ/kg K,
= 86996.8 × gen. air = 1.44,
= 86996.8 × 0.75 = 65247.6 kW cpg = 1.15 kJ/kg K and gases = 1.33.
Wnet = 65247.6 – 46757.6 = 18490 kW Refer to Fig. 14.4.
9PGV
F I
Hence, cycle = = 1
F 3.3 IJ
1.4 1
H %8 ª EQODWUVKQP
O
G
3U T2 p
GH JK
1.4
T1
2
p1 H 1.1K 1.369
=
T2 = 293 × 1.369 = 401 K
= 0.14 or 14% (Ans.)
T2 T1 401 293
(iii) Specific fuel consumption: compressor (L.P.) = 0.82 =
T2 T1 T2 293
Specific fuel consumption
H
O FG 401 293 IJ + 293 = 425 K
=
=
T2 =
H 0.82 K
= 0.644 kg/kWh (Ans).
F I
1
F 9.45 IJ
1.4 1
G
Q.14.5. (Gas turbine plant): Air is taken in a gas T4 p
GH JK
1.4
turbine plant at 1.1 bar, 20°C. The plant comprises of L.P.
Again,
T3
4
p3 H 3.15 K 1.369
and H.P. compressors and L.P. and H.P. turbines. The
compression in L.P. stage is upto 3.3 bar followed by T4 = 300 × 1.369 = 411 K
intercooling to 27°C. The pressure of air after H.P.
T(K)
compressor is 9.45 bar. Loss in pressure during intercooling
r
ba
is 0.15 bar. Air from H.P. compressor is transferred to heat
45
r
ba
ba
9.
exchanger of effectiveness 0.65 where it is heated by the gases
62
5
3.
3.
6
from L.P. turbine. After heat exchanger the air passes
r
973
ba
943 8
through combustion chamber. The temperature of gases
1
1.
supplied to H.P. turbine is 700°C. The gases expand in H.P. 7¢
7 9¢
turbine to 3.62 bar and air then reheated to 670°C before
expanding in L.P. turbine. The loss of pressure in reheater 9
5
is 0.12 bar. Determine :
(i) The overall efficiency. r
ba ar
(ii) The work ratio. 3
3. 15 b
4¢ 2¢ 3.
(iii) Mass flow rate when the power generated is 4
6000 kW.
2
Assume : Isentropic efficiency of compression in both 300
293 3
stages = 0.82. 1
Isentropic efficiency of expansion in turbines = 0.85. s
For air : cp = 1.005 kJ/kg K, = 1.4.
Fig. 14.4
For gases : cp = 1.15 kJ/kg K, = 1.33.
Neglect the mass of fuel. (IES) T4 T3
Solution. Given : T1 = 20 + 273 = 293 K, Now, compressor (H.P.) =
T4 T3
p1 = 1.1 bar, p2 = 3.3 bar,
411 300
T3 = 27 + 273 = 300 K, 0.82 =
T4 300
p3 = 3.3 – 0.15 = 3.15 bar,
p4 = p6 = 9.45 bar, T6 = 973 K, FG 411 300 IJ + 300 = 435 K
T8 = 670 + 273 = 943 K,
T4 =
H 0.82 K
642 POWER PLANT ENGINEERING
G
T6 p
GH JK
1.33 Net work done
Similarly,
T7
6
p7 H 3.62 K 1.268 overall =
Heat supplied
T6 973 [Wturbine (H.P.) Wturbine (L.P.) ]
T7 = = 767 K
1.268 1.268 [Wcomp. (L.P.) Wcomp. (H.P.) ]
=
T T7 Heat supplied
Also,turbine (H.P.) = 6
T6 T7
(201.25 230) (132.66 135.67)
973 T7 =
0.85 = 555.45
973 767
162.92
or, T7 = 973 – 0.85(973 – 767) = 798 K = = 0.293 or 29.3%. (Ans.)
555.45
(ii) Work ratio:
F I
1
F 3.5 IJ
1.33 1
G
T8 p
GH JK
1.33
Again,
T9
8
p9 H 1.1K 1.332
Work ratio =
0GV YQTMFQPG
6WTDKPGYQTM
T8 943 =9VWTDKPG
*2
9VWTDKPG
.2 ?
T9 = = 708 K
1.332 1.332 =9EQOR
.2
9EQOR
*2 ?
=
T8 T9 =9VWTDKPG
*2
9VWTDKPG
.2 ?
turbine (L.P.) =
T8 T9
943 T9 =
0.85 =
943 708
T9 = 943 – 0.85(943 – 708) = 743 K. = = 0.377
Effectiveness of heat exchanger,
i.e., Work ratio = 0.377 (Ans.)
T T4 .
= 0.65 = 5 (iii) Mass flow rate, m:
T9 T4
Net work done = 162.92 kJ/kg
T 435 Since mass of fuel is neglected, for 6000 kW, mass
i.e., 0.65 = 5
743 435 flow rate,
T5 = 0.65(743 – 435) + 435 = 635 K
O = = 36.83 kg/s
Wturbine (H.P.) = cpg (T6 – T7)
i.e., Mass flow rate = 36.83 kg/s (Ans.)
= 1.15(973 – 798)
Q.14.6. (Gas turbine): A gas turbine utilizes two-
= 201.25 kJ/kg of gas
stages centrifugal compressor. The pressure ratios for the
Wturbine (L.P.) = cpg(T8 – T9) first and second stages are 2.5 and 2.1 respectively. The
= 1.15(943 – 743) flow of air is 10 kg/s, this air being drawn at 1.013 bar
= 230 kJ/kg of gas and 20°C. If the temperature drop in the intercooler is 60°C
and the isentropic efficiency is 90% for each stage, calculate:
Wcompressor (L.P.) = cpa(T2 – T1)
(i) The actual temperature at the end of each stage.
= 1.005(425 – 293)
(ii) The total compressor power.
= 132.66 kJ/kg of air
Assume = 1.4 and cp = 1.005 kJ/kg K for air.
Wcompressor (H.P.) = cpa(T4 – T3)
(IES)
= 1.005(435 – 300)
R R
= 135.67 kJ/kg of air Solution. Given : = 2.5; = 2.1; m
= 10 kg/s;
R R
Heat supplied = cpg(T6 – T5) + cpg(T8 – T7)
p1 = 1.013 bar; T1 = 20 + 273 = 293 K; Temperature
= 1.15(973 – 635) + 1.15(943 – 798) drop in intercooler; T2 – T3 = 60°C; isen = 90%, = 1.4;
= 555.45 kJ/kg of gas cp = 1.005 kJ/kg K for air.
‘GATE’ AND ‘UPSC’ EXAMINATIONS’ QUESTIONS (LATEST-SELECTED) WITH ANSWERS/SOLUTIONS 643
(i) Actual temperature at the end of each stage, Impeller tip diameter, D1:
T2, T3: Velocity of flow at inlet,
For isentropic compression:
%H = 120 cos 20° = 112.76 m/s
6 ⎛R ⎞ 6 Velocity of whirl at inlet,
= ⎜ ⎟ or =
6 ⎝ R ⎠
%Y = 120 sin 20° = 41.04 m/s
or, T2 = 380.68 K
Peripheral velocity at inlet,
6 6
Also, isen = or 0.9 = & 0
6 6 6 %DN = =
or, 0.9 (T2 – 293) = 380.68 – 293 = 87.68
= 167.55 m/s
or, T2 = + 293 = 390.42 K (Ans.)
and, T3 = 390.42 – 60 = 330.42 K (Ans.)
C1
20
Cr
=
°
1
(ii) Total compressor power: Cf
12
1
0
Compressor power
m
/s
p [(T2 – T1) × (T4 – T3)]
= mc …(i)
Cw
1
Cbl
1
6 ⎛R ⎞ 6
Now, = ⎜ ⎟ or =
6 ⎝ R ⎠ Fig. 14.5
%Y
or, T4 = 330.42
= 408.44 K Slip factor, s = 0.85 = , %Y = 0.85 %DN
%DN
and the slip factor is 0.85. Guide vanes at inlet give the air = (0.85 %DN × %DN – 41.04
an angle of prewhirl of 20° to the axial direction. The mean × 167.55)
diameter of the impeller eye is 200 mm and the absolute air
velocity at inlet is 120 m/s. Calculate the impeller tip = 0.85 %DN – 6876.25 …(ii)
diameter. (IES) Equating eqns. (i) and (ii), we get:
Solution. Given : N = 16000 rpm; T1 = 17 + 273
0.85 %DN – 6876.25 = 172.66 × 103
= 290 K; Pressure ratio, rp = 4; isen = 82%; Slip factor,
s = 0.85, inlet prewhirl angle = 20° (to axis direction); Mean ⎛ ⎞
impeller diameter, D1 = 280 mm = 0.2 m; Absolute air %DN = ⎜⎜ ⎟⎟
⎝ ⎠
velocity at inlet, C1 = 120 m/s.
Refer to Fig. 14.5. = 459.6 m/s
644 POWER PLANT ENGINEERING
& 0 p (bar)
But, %DN = or
3 T2 2
p2 = 7
&
459.6 =
1.3
pV =C
or, D2 =
= 0.548 m or 548 mm (Ans.)
Q.14.8. (Reciprocating compressors): A single- Co
Ex
stage, double-acting compressor has a free air delivery m
pan
pr
es
(F.A.D.) of 14 m3/min. measured at 1.013 bar and 15°C.
sio
sio
T1 = 305 K n
The pressure and temperature in the cylinder during
n
4 1
p1 = 0.95
induction are 0.95 bar, 32°C. The delivery pressure is 7 bar
and index of compression and expansion, n = 1.3. The
clearance volume is 5% of the swept volume. Calculate : Vc V4 V1 V (m3)
Vs
(i) Indicated power required ; = 0.05 Vs
(ii) Volumetric efficiency. (GATE) Fig. 14.6
Solution. 1.3
Free air delivery, = × 17.16 × 0.287 (483.5 – 305)
1.3 1
F.A.D. = 14 m3/min. (measured at 1.013 bar = 3809.4 kJ/min.
and 15°C) Indicated power
Induction pressure, p1 = 0.95 bar
3809.4
Induction temperature,T1 = 32 + 273 = 305 K = = 63.49 kW. (Ans.)
60
Delivery pressure, p2 = 7 bar
(ii) Volumetric efficiency :
Index of compression and expansion, n = 1.3 Using the relation:
Clearance volume, V3 = Vc = 0.05 Vs
F p I = FG p IJ
1/ n 1/1.3
Refer to Fig. 14.6.
(i) Indicated power :
V4
V3
= GH p JK H p K
3
4
2
1
m=
pV
RT
=
1.013 10 14
0.287 288 103
3
H 0.95 K
V4 = 4.65 × V3 = 4.65 × 0.05 Vs = 0.233 Vs
= 17.16 kg/min.
V1 – V4 = V1 – 0.233Vs = 1.05 Vs – 0.233 Vs
where, F.A.D. per minute is V at p(= 1.013 bar)
= 0.817 Vs
and, T(= 15 + 273 = 288 K)
To find T2, using the equation, pV p (V V4 )
Now, m= = 1 1
RT RT1
F p I , we have:
n1
T2
GH p JK
n
2
= T p
T1 1 i.e., F.A.D./cycle, V = (V1 – V4) . 1
T1 p
Fp I
n1
(where p1 and T1 are the suction conditions)
=T G J
n
or, T2 2
1
Hp K 1 V = 0.817 Vs ×
288
×
0.95
305 1.013
F 7 IJ = 483.5 K
1.3 1
= 0.723 Vs
= 305 × G
1.3
H 0.95 K Volumetric efficiency,
Indicated power V 0.723 Vs
vol. = =
n Vs Vs
= mR(T2 – T1)
n1 = 0.723 or 72.3%. (Ans.)
‘GATE’ AND ‘UPSC’ EXAMINATIONS’ QUESTIONS (LATEST-SELECTED) WITH ANSWERS/SOLUTIONS 645
Q.14.9. (Steam nozzle): Steam nozzle is supplied Exit area of the nozzle,
steam at 15 bar 350°C and discharges steam at 1 bar. If m v3 0.0662 1.75
A3 = = = 0.0001156 m2
the diverging portion of the nozzle is 80 mm long and the C3 1001.5
throat diameter is 6 mm, determine the cone angle of the 2
divergent portion. Assume 12% of the total available i.e., D = 0.0001156
4 3
enthalpy drop is lost in friction in the divergent portion.
FG 4 0.0001156IJ 1/2
Also determine the velocity and temperature of the steam at
throat. (IES)
D3 =
H K = 0.012 m or 12.1 mm
h (kJ/kg)
angles for the first-row of moving blades, the fixed blades,
15
h1 = 3150 1
ba
r and the second row of moving blades are 18°, 21° and 35°
350°C
8.
19 respectively.
(i) Calculate the blade inlet angles for each row.
r
ba
270°C
(ii) Calculate also for each row of moving blades,
1
h2 = 2992 2
the driving force and the axial thrust on the
wheel for a mass flow of 1 kg/s.
Saturation (iii) Calculate the diagram efficiency for the wheel
line and the diagram power per kg/s steam flow.
3¢
h3 = 2580
3 (iv) What would be the maximum possible
diagram efficiency for the given steam inlet
velocity and nozzle angle?
s (kJ/kg K)
Take the blade velocity co-efficient as 0.9 for all
Fig. 14.7 blades. (IES)
Solution. Refer to Fig. 14.8.
From Mollier chart :
= 16°, = 18°, C1 = 600 m/s, Cbl = 120 m/s,
h1 = 3150 kJ/kg, h2 = 2992 kJ/kg
= 21°, = 35°, m s = 1 kg/s,
v2 = 0.24 m3/kg, h3 = 2580 kJ/kg
Blade velocity co-efficient, K = 0.9.
v3 = 1.75 m3/kg, t2 = 270°C
With the above data velocity triangles can be drawn.
i.e., Temperature of the steam at throat
From the diagram, by measurement:
= 270°C. (Ans.)
Velocity of steam at throat, Cw = Cw1 Cw0 = 875 m/s ;
Cw = Cw + Cw = 875 m/s
1 0
Cw Cw
1 0
Cbl
M L
P a Q
f
q b
C0 Cf0
Cr1
Cf1
Cr =
m/s 0 0.9 C
600 a = 16° r1
C 1=
q = 18°
N
S First row of
moving blades
Fig. 14.8
Cw = C w + C w
1 0
(ii) The diagram power :
Cw Cw
1 0 Diagram power = m s C C
Cbl w bl
P
M L
Q Now, Cw = 2C1 cos – Cbl
q f 20° 20° a b
= 2 × 90 × cos 20° – 41.04 = 128.1 m/s
Cr C0
Cf
1
1 Cf 9000 128.1 41.04
/s
0
Diagram power =
90 m Cr 3600 1000
C 1= 0
= 13.14 kW. (Ans.)
S N
(iii) The diagram efficiency :
(a)
Rate of doing work per kg/s
h = Cw Cbl = 128.1 × 41.04 Nm/s
Also, energy input to the moving blades per stage
2 2 2 2
C12 Cr0 Cr1 C 2 C1 Cr1
D = 1
2 2 2 2
Cr1 2
= C12 (∵ Cr0 C1 )
2 2
Area A m
Referring to Fig. 14.9 (a), we have:
Solution. (a) The comparison between the ‘fire-tube boilers’ and ‘water-tube boiler’ is given below:
1. Position of water and hot gases Hot gases inside the tubes Water inside the tubes and
and water outside the tubes. hot gases outside the tubes.
2. Mode of firing Generally internally fired. Externally fired.
3. Operating pressure Operating pressure limited Can work under as high
to 16 bar. pressure as 100 bar
4. Rate of steam production Lower Higher
5. Suitability Not suitable for large power plants Suitable for large power plants
6. Risk on bursting Involves lesser risk on explosion Involves more risk on bursting due
due to lower pressure to high pressure.
7. Floor area For a given power it occupies more For a given power it occupies less
floor area floor-area.
8. Construction Difficult Simple
9. Transportation Difficult Simple
10. Shell diameter Large for same power Small for same power
11. Chances of explosion Less More
12. Treatment of water Not so necessary More necessary
13. Accessibility of various parts Various parts not so easily accessible Various parts are more accessible.
for cleaning, repair and inspection.
14. Requirement of skill Require less skill for efficient and Require more skill and careful
economic working attention.
(b) Before feeding the water (as make up water) to Significance of the parameters:
the boiler it is adequately treated. Still, it has some (i) “Air rate” is significant in deciding the size of the
impurities in the form of total dissolved solids (TDS). These compressor.
solids are expressed in ppm (parts per million). In order, (ii) “Specific power” decides the efficiency of the
to maintain a certain ppm in the drum, ‘blow down’ is combustion process and also conveys whether complete
necessary. Trisodium phosphate or tanin is injected in combustion is taking place or not.
suitable doses periodically to help precipitate the salts at (iii) “Work ratio” is significant in deciding the ratio
the bottom of the drum. between (WT – WC) and (WT) and hence efficiency of the
Q.14.13. Defined air rate, specific power and the cycle cycle.
work ratio in a gas turbine. What is the significance of these Q.14.14. Using a layout diagram describe a gas
parameters? (IES) turbine plant for turbo-jet (IES)
Solution. Fig. 14.10 shows a turbo-jet unit.
Solution. (i) Air rate: It is defined as air supplied
l It consists of diffuser at entrance which slows
per second in a gas turbine cycle for combustion of fuel.
down the air (entering at velocity equal to the
(ii) Specific power: The power output per unit mass
plane speed) and part of the kinetic energy of
of air supplied per second is termed as “specific power”. the air stream is converted into pressure ; this
(iii) Cycle work ratio: The ‘work ratio’ in a gas type of compression is called as ram
turbine cycle is defined as the ratio of network output to compression.
the gross work output. l The air is further compressed to a pressure of 3
In other words: to 4 bar in a rotary compressor (usually of axial
flow type).
0GVYQTMQWVRWV
Work ratio = l The compressed air then enters the combustion
)TQUUYQTMQWVRWV
chamber (C.C.) where fuel is added. The
9QTMQHGZRCPUKQP
96 9QTMQHEQORTGUUKQP
9% combustion of fuel takes place at sensibly
= constant pressure and subsequently
9QTMQHGZRCPUKQP
96
temperature rises rapidly.
96 9% l The hot gases then enter the gas turbine where
or, Work ratio =
96 partial expansion takes place. The power
‘GATE’ AND ‘UPSC’ EXAMINATIONS’ QUESTIONS (LATEST-SELECTED) WITH ANSWERS/SOLUTIONS 649
1. Throttling losses Severe No throttling losses (Actually there are a little throttling
losses in nozzles valves which are partially open).
2. Partial admission losses Low High
3. Heat drop available Lesser Larger
4. Use Used in impulse and Used in impulse and also in reaction (if initial stage
reaction turbines both. impulse) turbines.
5. Suitability Small turbines Medium and larger turbines.
(b) The hydro-mechanical speed governing system the governor hydraulically amplifies the error signal and
(prime control) uses a centrifugal governor (mechanical) provides an actual output position that can be linked to a
to sense the speed of the turbine and the reference is set fuel valve. The fuel valve either throttles or bypasses the
for rated sense of the turbine. The governor senses the speed metered fuel from the main fuel control. The speed sensing
through the accessory drive shaft and fly weights. Initially, device may be electrical or hydraulic.
650 POWER PLANT ENGINEERING
Q.14.17. Discuss the relative merits and demerits of axial flow compressors over centrifugal compressors. (IES)
Solution. The relative merits and demerits of axial flow compressors over centrifugal compressors are given in a
tabular form below:
11. Applications Used in blowing engines in steel mills, Mostly used in jet engines (due to
low pressure refrigeration, big central higher efficiency and smaller
air conditioning plants, fertiliser and frontal area). Also preferred in
industry, supercharging I.C. engines, power plant gas turbines and steel
gas pumping in long distance pipe mills.
lines etc.
— Previously it was used in jet
engines
12. Efficiency vs. speed curve More flat Less flat comparatively
Q.14.18. What are the constructional features of an Inlet guide Stator (Casing) Delivery
vanes
axial flow compressor? How air is compressed and what is vanes
blades. The rotor blades are mounted on the Fig. 14.12. Axial flow compressor.
rotating drum and stator blades are fixed to the The “fixed blades” serve the following two purposes:
casing stator. One stage of the machine comprises
(i) Convert a part of the K.E. of the fluid into pressure
a row of rotor blades followed by a row of stator
energy. This conversion is achieved by diffusion process
blades.
carried out in the diverge blade passages.
l For efficient operation the blades are of air foil
(ii) Guide and redirect the fluid flow so that entry to
section based on aerodynamic theory. The blades
the next stage is without shock.
are so designed that wasteful losses due to shock
and turbulence are prevented and the blades are Working
free from stalling troubles. (The blades are said Basically, the compression is performed in a similar
to be stalled when the air stream fails to follow manner to that of the centrifugal type. The work input to
the blade contour). Whereas the compressor the rotor shaft is transferred by the moving blades to the
blades have aerofoil section, the turbine blades air, thus accelerating it. The blades are so arranged that
have profiles formed by a number of circular arcs. the spaces between the blades form diffuser passages, and
This is so because the acceleration process being hence the velocity of the air relative to the blades is decreased
carried out in the converging blade passages of as the air passes through them, and there is a rise in
a reaction turbine is much more efficient and pressure. The air is then further diffused in the stator blades,
stable process as compared with the diffusing or which are also arranged to form diffuser passages. In the
decelerating process being carried out in the fixed stator blades the air is turned through an angle so
diverging passage between the blades of an axial that its direction is such that it can be allowed to pass to a
flow compressor. second row of moving rotor blades. It is usual to have a
l The annular area is usually reduced from inlet relativity large number of stages and to maintain a constant
to outlet of the compressor. This is to keep the work input per stage (e.g., from 5 to 14 stages have been
flow velocity constant throughout the compressor used).
length. In the diverging passages of the moving —The necessary reduction in volume may be allowed by
blades, there is rise in temperature due to flaring the stator or by flaring rotor. It is more common to
diffusion. The absolute velocity is also increased use a flared rotor, and this type is shown diagrammatically
due to work input. in Fig. 14.12.
652 POWER PLANT ENGINEERING
—It is usually arranged to have an equal temperature rise bigger in diameter, while risers are more in number and
in the moving and the fixed blades, and to keep the axial smaller in diameter in a steam generator? (IES)
velocity of air constant throughout the compressor. Thus,
each stage of the compression is exactly similar with regard H.8
Solution. In a steam generator, p = , the
to air velocity and blade inlet and outlet angles. &
—A diffusing flow is less stable than a converging flow, downcomers are meant to move the water by gravity,
and for this reason the blade shape and profile is much ‘bigger’ the diameter (D) ‘less’ the pressure drop (p) due
more important for a compressor than for a reaction
turbine. The design of compressor blades is based on to friction since p . Hence, the downcomers are made
aerodynamic theory and an aerofoil shape is used. &
Q.14.19. What do you mean by supersaturated flow biggers in diameter, which way vary from 150 mm to
through steam nozzles? Discuss the causes of 200 mm or even higher?
supersaturation phenomena. (GATE) Q.14.21. Why are steam turbines compounded? What
Solution. Refer to Art. 3.18.5. are methods of compounding? (GATE)
Q.14.20. Why are downcomers fewer in number and Solution. Refer to Art. 3.19.5.
l The function of ‘coolant’ is to remove the intense (c) thermal efficiency increases
heat produced in the reactor and to bring out (d) heat input increases.
for being utilized. Ans. (c)
Q.14.4. Consider the following statements: Explanation: In a gas turbine cycle with
1. The gases measured directly by Orsat ‘regeneration’ thermal efficiency increases (the
apparatus from a flue gas sample are CO2, exhaust gases from a gas turbine carry a large
O2 and N2. quantity of heat with them since their
2. Bomb calorimeter measures higher calorific temperature is far above the ambient
value of fuel at constant pressure. temperature, so they can be used to heat the
3. For burning 1 kg of fuel (carbon) to carbon air coming from the compressor thereby
monoxide, the stoichiometric quantity of air reducing the mass of fuel supplied in the
required is 8/3 kg. combustion chamber).
Which of these statements is/are correct? Q. 14.8. In a normal shock wave in one dimensional flow
(a) Only 1 (b) Only 2 (a) the entropy remains constant
(c) Only 3 (d) 1, 2 and 3. (b) the entropy increases across the shock
Ans. (c) (c) the entropy decreases across the shock
Explanation: (d) the velocity, pressure and density increase
l The gases measured directly by ‘Orsat across the shock.
apparatus’ from a flue gas sample are CO2, O2 Ans. (b)
and CO (not N2). Explanation: In a normal shock wave in one
l A ‘bomb calorimeter’ measures the higher or dimensional flow there is always a change from
gross calorific value because the fuel sample is supersonic to subsonic speed which involves
burnt at a constant volume (not constant pressure rise and never the reverse. As per
pressure). second law of thermodynamics, entropy always
Q. 14.5. The mass defect is increases during irreversible adiabatic change,
(a) a characteristic of certain elements thus entropy increases across the shock.
Q. 14.9. Uranium 238 is represented as 92U238. What does
(b) a term used to prove the relationship between
it imply?
mass and energy
(a) It has 92 protons and 146 neutrons
(c) a measure of fission energy
(b) It has 146 protons and 92 electrons
(d) the difference between mass of the nucleus
and sum of the masses of the nucleons. (c) It has 92 protons and 238 neutrons
Ans. (d) (d) It has 92 neutrons and 238 protons.
Explanation: The difference between mass of Ans. (a)
the nucleus and sum of the masses of nucleons Explanation: Uranium 238 is represented as
is termed as “mass defect”. 92
U238 i.e., number of proton atomic number =
Q. 14.6. The ratio of the static enthalpy rise in the rotor 92 and 10 number of neutron = 238 – 92 = 146.
to the static enthalpy rise in the stage of an axial Q. 14.10. Water-tube boilers are preferred for
flow compressor is defined as (a) high pressure and high output
(a) power input factor (b) high pressure and low output
(b) flow coefficient (c) low pressure and high output
(c) temperature coefficient (d) low pressure and low output.
(d) degree of reaction. Ans. (a)
Ans. (d) Explanation: Water-tube boilers are preferred
Explanation: In an axial flow compressor for high pressure and high output.
degree of reaction (Rd) is defined as the ratio of These boilers are used exclusively, when
pressure rise in the compressor stage. It is equal pressure above 10 bar and capacity in excess of
to the ratio of static enthalpy rise in the rotor 7000 kg of steam per hour, is required. ‘Babcock
to the static enthalpy rise in the stage of an axial and Wilcox water-tube boiler’ is an example of
flow compressor. horizontal straight tube boiler and may be
Q. 14.7. In a gas turbine cycle with regeneration designed for stationary or marine purposes.
(a) pressure ratio increases Q. 14.11. Given:
(b) work output decreases s = stage efficiency
654 POWER PLANT ENGINEERING
(c) Nozzle flow with friction section. The value of the Mach number at the
(d) Supersaturated flow of steam through a throat is
nozzle. (a) < 1 (b) Equal to 1
Ans. (d) (c) > 1 (d) 1.
Explanation: Wilson line is associated with the Ans. (b)
supersaturated flow of steam through a nozzle. Explanation: In a converging-diverging nozzle
The limiting condition of under-cooling at which the value of Mach number at the throat is
condensation commences and is assumed to always unity i.e., M = 1.
restore conditions of normal thermal Q. 14.28. Blade erosion in steam turbines takes place
equilibrium is called the “Wilson line”. (a) Due to high temperature steam
Q. 14.25. Which one of the following expresses the (b) Due to droplets in steam
maximum blade efficiency of a Parsons’ turbine?
(c) Due to high rotational speed
EQU EQU (d) Due to high flow rate.
(a) (b)
EQU EQU Ans. (b)
Explanation: In steam turbines the blade
EQU EQU erosion takes place due to droplets in steam.
(c) (d) . When the speed is high and moisture exceeds
EQU
10 per cent the effect of moisture is most
Ans. (b) prominant. The most effected portion is the back
Explanation: The expression for maximum of the inlet edge of the blade, where either
blade efficiency of Parson’s turbine is given as: grooves are formed or even some portion breaks
away. Due to centrifugal force the water
EQU particles tend to concentrate in the outer
(bl)max = ,
EQU annulus and their tip speed is greater than the
root speed, hence corrosion effect is most on tips.
where, is the angle of discharging
Q. 14.29. Consider the following statements in respect of
The condition for maximum efficiency of a axial flow air compressors.
reaction turbine is derived by the following 1. An axial flow air compressor is often
assumptions: described as a reversed reaction turbine.
(i) The degree of reaction is 50%.
2. With 50% degree of reaction, the velocity
(ii) The moving and fixed blades are diagrams are symmetrical.
symmetrical.
Which of these statements is/are correct?
(iii) The velocity of steam at exit from the (a) 1 only (b) 2 only
preceding stage is same as velocity of steam
(c) Both 1 and 2 (d) Neither 1 nor 2.
at the entrance to the succeeding stage.
Ans. (c)
Q. 14.26. In a reaction turbine the enthalpy drop in a
stage is 60 units, the enthalpy drop in the Explanation: (c) is the correct answer because
moving blades is 32 units. The degree of reaction the working principle of an axial flow
is compressor is opposite to that of a reaction
turbine and the velocity diagrams of a reaction
(a) 0.533 (b) 0.284
turbine are symmetrical when the degree of
(c) 0.466 (d) 1.875 reaction is 50 per cent.
Ans. (a) Q. 14.30. Which one of the following boiler accessories
Explanation: The ‘degree of reaction’ (Rd) of does not need ‘flue-gas’ for its operation?
reaction turbine stage is defined as the ratio of (a) Economizer (b) Preheater
heat drop over the moving blades (hm) to the
(c) Injector (d) Superheater.
total heat drop (hf + hm) in the stage or,
Ans. (c)
JO Explanation: The function of an ‘injector’ is to
hd = = = 0.533
JH JO feed water into the boiler. It does not need fuel
gas for its operation. It is commonly employed
Q. 14.27. A converging diverging nozzle is connected to a for vertical and locomotive boilers and does not
gas pipeline. At the inlet of the nozzle find application in large capacity high pressure
(converging section) the Mach number is 2. It is boilers. It is also used where the space is not
observed that there is a shock in the diverging available for the installation of a feed pump.
‘GATE’ AND ‘UPSC’ EXAMINATIONS’ QUESTIONS (LATEST-SELECTED) WITH ANSWERS/SOLUTIONS 657
Q. 14.31. Which one of the following fittings is mounted efficiency may be increased or decreased
on the boiler to put off the fire in the furnace, depending upon the mean temperature of heat
when water level falls to an unsafe limit? addition.
(a) Feed check valve Q. 14.35. An open cycle constant pressure gas turbine
(b) Safety valve uses a fuel of calorific value 40,000 kJ/kg, with
(c) Fusible plug air fuel ratio of 80 : 1 and develops a net output
(d) Blow-off-cock. of 80 kJ/kg of air. The thermal efficiency of the
Ans. (c) cycle is
Explanation: The function of a ‘fusible plug’ is (a) 61% (b) 16%
to protect the boiler against damage due to over (c) 18% (d) None of these.
heating for low water level. It is mounted on Ans. (b)
the fire box crown plate to put off the fire in the Explanation: Given: Calorific value = 40000
furnace when the water level falls to an unsafe
kJ/kg
limit.
Q. 14.32. Which one of the following statements is correct a /m
m f = 80 : 1
about the Fanno flow? Wout = 80 kJ/kg of air
(a) For an initially subsonic flow, the effect of 9QTM QWVRWV
9QWV
friction is to decrease the Mach number thermal =
*GCVUWRRNKGF
3KP
towards unity
(b) For an initially supersonic flow, the effect of O C
=
friction is to increase the Mach number H
O
towards unity
(c) At the point of maximum entropy, the Mach = = 0.16 or 16%
number is unity
Q. 14.36. A centrifugal compressor is suitable for which
(d) Stagnation pressure always increases along
of the following?
the Fanno line.
Ans. (c) (a) High pressure ratio, low mass flow
Explanation: In case of ‘Fanno flow’ the Mach (b) Low pressure ratio, low mass flow
number (M) is unity at the point of maximum (c) High pressure ratio, high mass flow
entropy. (d) Low pressure ratio, high mass flow.
Q. 14.33. The turbine of the turbo-prop engine as Ans. (d)
compared to that of turbo-jet engine is Explanation: A centrifugal pressure is suitable
(a) similar (b) smaller for low and medium pressures (pressure ratio
(c) bigger (d) unpredictable. about 3 to 4.5) and high mass flow (large gas
Ans. (c) volumes).
Explanation: The turbine of the turbo-prop Q. 14.37. The suction pressure is 1 bar and delivery
engine as compared to that of a turbo-jet engine pressure is 125 bar. What is the ideal
is bigger because in the former case turbine intermediate pressure at the end of first stage
expansion process is greater than that of the for a 3-stage air compressor?
latter one. (a) 25 bar (b) 5 bar
Q. 14.34. Consider the following statements in respect of (c) 10 bar (d) 20 bar.
gas turbines:
Ans. (b)
A gas turbine plant with reheater leads to a
Explanation: Suction pressure = 1 bar
1. Considerable improvement in the work
output. Ideal intermediate pressure at the end of 1st
stage = (5)1 = 5 bar.
2. Considerable improvement in the thermal
efficiency. (Pressure after 2nd stage = (5)2 = 25 bar,
Which of these statements is/are correct? pressure after 3rd stage = (5)3 = 125 bar)
(a) 1 only (b) 2 only Q. 14.38. A nuclear reactor is said to be critical when the
(c) Both 1 and 2 (d) Neither 1 nor 2. neutron population in the reactor core is
Ans. (a) (a) rapidly increasing leading to the point of
Explanation: In a gas turbine ‘reheating’ explosion
increases the work output but the thermal (b) decreasing from a specific value
658 POWER PLANT ENGINEERING
(c) axial length of the compressor would be Explanation: The correct choice is (d), because
increased a normal shock can exist between 1 and 2
without affecting the test conditions, as it can
(d) axial length of the compressor would be
be swallowed through the second throat by
decreased.
making it larger than first.
Ans. (b) Q. 14.51. Intercooling in gas turbines
Explanation: The choice (b) is correct, because (a) decrease net output but increases thermal
in case of axial flow stages, diameter is less and efficiency
same, but in case of centrifugal compressor, the (b) increases net output but decreases thermal
flow is radial at outlet and hence overall efficiency
diameter will increase. (c) decreases both net output and thermal
Q. 14.49. If the velocity of propagation of small efficiency
disturbances in air at 27°C is 300 m/s, then at a (d) increases both net output and thermal
temperature of 54°C, its speed would be efficiency
Ans. (b)
(a) 660 m/s (b) 300 × 2 m/s Explanation: In a gas turbine, intercooling is
employed to compressor air in two stages (with
327
(c) 300/ 2 m/s (d) 330 m/s. intercooling the work done on the compressor
300 decreases and consequently net output of turbine
Ans. (d) increases). However more heat has to be added
in the combustion chamber which results in
Explanation: Velocity of propagation of small
decrease in thermal efficiency.
disturbance, V T Q. 14.52. The inlet and exit velocity diagrams of a
turbomachine rotor are shown in the Fig. 14.16.
V54C (54 273) The turbo-machine is
=
V27°C (27 273)
327 u1 u2
or, V54°C = 300 m/s.
300
Fig. 14.16
Q. 14.50. Fig. 14.15 represents a schematic view of the
(a) an axial compressor with backward curved
arrangement of a supersonic wind tunnel
blades
section. A normal shock can exist without
affecting the test conditions (b) a radial compressor with backward curved
blades
(c) a radial compressor, with forward curved
1 2 3 4 5
blades
(d) an axial compressor with forward curved
Supersonic blades
test section
Supersonic Ans. (c)
Supersonic diffuser
nozzle 1 Explanation: From inlet and exist velocity
2 3 4 5 diagrams of a turbomachine rotor it is evident
that u2 > u1, which means that it is a radial
Fig. 14.15
compressor (for axial compressor u2 = u1).
(a) between sections 4 and 5 Further in outlet velocity triangle, Vr2 is in the
(b) at section 4 direction of u2 which means blades are formed
curved (in case of backward curved blades the
(c) between sections 4 and 3 direction of Vr2 will be opposite to that of u2, the
(d) between sections 1 and 2. angle between Vr2 and u2 will be acute). Thus
Ans. (d) (c) is the correct choice.
‘GATE’ AND ‘UPSC’ EXAMINATIONS’ QUESTIONS (LATEST-SELECTED) WITH ANSWERS/SOLUTIONS 661
Q. 14.53. For a multi-stage compressor, the polytropic (c) regulate steam flow
efficiency is (d) regulate water flow
(a) the efficiency of all stages combined together Ans. (a)
(b) the efficiency of one stage Explanation: In a Babcock-Wilcox boiler
(c) constant throughout for all the stages baffles are provided in between water tubes to
have better contact of flue gases with water tubes.
(d) a direct consequence of the pressure ratio.
Q. 14.55. Which of the following boilers can generate
Ans. (c) superheated steam without additional
Explanation: The polytropic efficiency is accessories?
defined as the isentropic efficiency of an element (a) Cochran boiler
stage of compressor which is constant (b) Cornish boiler
throughout the whole process.
(c) Lancashire boiler
Q. 14.54. In a Babcock-Wilcox boiler baffles are provided (d) Locomotive boiler
in between water tubes to
Ans. (d)
(a) have better contact of flue gases with water Explanation: Locomotive boiler can generate
tubes superheated steam without additional
(b) prevent buckling of water tubes accessories.
OBJECTIVE TYPE QUESTIONS BANK
Objective Type Questions Bank
665
666 POWER PLANT ENGINEERING
17. Rankine cycle efficiency of a good steam power plant (c) is same as simple Rankine cycle thermal
may be in the range of efficiency
(a) 15 to 20% (b) 35 to 45% (d) is always less than simple Rankine cycle thermal
(c) 70 to 80% (d) 90 to 95%. efficiency.
18. Rankine cycle operating on low pressure limit of p1 24. In a regenerative feed heating cycle, the optimum
and high pressure limit of p2 value of the fraction of steam extracted for feed
(a) has higher thermal efficiency than the Carnot heating
cycle operating between same pressure limits (a) decreases with increase in Rankine cycle
(b) has lower thermal efficiency than Carnot cycle efficiency
operating between same pressure limits (b) increases with increase in Rankine cycle
(c) has same thermal efficiency as Carnot cycle efficiency
operating between same pressure limits (c) is unaffected by increase in Rankine cycle
(d) may be more or less depending upon the efficiency
magnitude of p1 and p2. (d) none of the above.
19. Rankine efficiency of a steam power plant
25. In a regenerative feed heating cycle, the greatest
(a) improves in summer as compared to that in economy is affected
winter
(a) when steam is extracted from only one suitable
(b) improves in winter as compared to that in point of steam turbine
summer
(b) when steam is extracted from several places in
(c) is unaffected by climatic conditions
different stages of steam turbine
(d) none of the above.
(c) when steam is extracted only from the last stage
20. Carnot cycle comprises of of steam turbine
(a) two isentropic processes and two constant
(d) when steam is extracted only from the first stage
volume processes
of steam turbine.
(b) two isentropic processes and two constant
26. The maximum percentage gain in regenerative feed
pressure processes
heating cycle thermal efficiency
(c) two isothermal processes and two constant
pressure processes (a) increases with number of feed heaters increasing
(d) none of the above. (b) decreases with number of feed heaters increasing
21. In Rankine cycle the work output from the turbine (c) remains same unaffected by number of feed
is given by heaters
(a) change of internal energy between inlet and (d) none of the above.
outlet 27. In regenerative cycle feed water is heated by
(b) change of enthalpy between inlet and outlet (a) exhaust gases
(c) change of entropy between inlet and outlet (b) heaters
(d) change of temperature between inlet and outlet. (c) draining steam from the turbine
22. Regenerative heating i.e., bleeding steam to reheat
(d) all above.
feed water to boiler
28. Reheat cycle in steam power plant is used to
(a) decreases thermal efficiency of the cycle
(b) increases thermal efficiency of the cycle (a) utilise heat of flue gases
(c) does not affect thermal efficiency of the cycle (b) increase thermal efficiency
(d) may increase or decrease thermal efficiency of (c) improve condenser performance
the cycle depending upon the point of extraction (d) reduce loss of heat.
of steam. 29. Mercury is a choice with steam in binary vapour
23. Regenerative cycle thermal efficiency cycle because it has
(a) is always greater than simple Rankine thermal (a) higher critical temperature and pressure
efficiency
(b) higher saturation temperature than other fluids
(b) is greater than simple Rankine cycle thermal
efficiency only when steam is bled at particular (c) relatively low vaporisation pressure
pressure (d) all of the above.
OBJECTIVE TYPE QUESTIONS BANK 667
30. Binary vapour cycles are used to (a) decreases if the chimney gas temperature
(a) increase the performance of the condenser increases
(b) increase the efficiency of the plant (b) increases if the chimney gas temperature
(c) increase efficiency of the turbine. increases
(c) remains same irrespective of chimney gas
STEAM POWER PLANT temperature
(d) may increase or decrease.
31. A steam power station requires space
39. For forced draught systems, the function of chimney
(a) equal to diesel power station is mainly
(b) more than diesel power station (a) to produce draught to accelerate the combustion
(c) less than diesel power station. of fuel
32. Economiser is used to heat (b) to discharge gases high up in the atmosphere to
(a) air (b) feed water avoid hazard
(c) flue gases (d) all above. (c) to reduce the temperature of the hot gases
33. The modern steam turbines are discharged
(a) impulse turbines (d) none of the above.
(b) reaction turbines 40. Artificial draught is produced by
(c) impulse-reaction turbines (a) induced fan (b) forced fan
(d) none of the above. (c) induced and forced fan (d) all of the above.
34. The draught which a chimney produces is called 41. The draught in locomotive boilers is produced by
(a) induced draught (b) natural draught (a) forced fan
(b) chimney
(c) forced draught (d) balanced draught.
(c) steam jet
35. The draught produced by steel chimney as compared
to that produced by brick chimney for the same (d) only motion of locomotive.
height is 42. For the same draught produced the power of induced
(a) less (b) more draught fan as compared to forced draught fan is
(c) same (d) may be more or less. (a) less (b) more
36. In a boiler installation the natural draught is (c) same (d) not predictable.
produced 43. Artificial draught is produced by
(a) due to the fact that furnace gases being light go (a) air fans (b) steam jet
through the chimney giving place to cold air from (c) fan or steam jet (d) all of the above.
outside to rush in 44. The artificial draught normally is designed to
(b) due to the fact that pressure at the grate due to produce
cold column is higher than the pressure at (a) less smoke
chimney base due to hot column (b) more draught
(c) due to the fact that at the chimney top the pres- (c) less chimney gas temperature
sure is more than its environmental pressure (d) all of the above.
(d) all of the above. 45. For the induced draught the fan is located
37. The draught produced, for a given height of the (a) near bottom of chimney
chimney and given mean temperature of chimney
(b) near bottom of furnace
gases
(c) at the top of the chimney
(a) decreases with increase in outside air tempera-
ture (d) anywhere permissible.
(b) increases with increase in outside air tempera- 46. The pressure at the furnace is minimum in case of
ture (a) forced draught system
(c) remains the same irrespective of outside air tem- (b) induced draught system
perature (c) balanced draught system
(d) may increase or decrease with increase in out- (d) natural draught system.
side air temperature. 47. For maximum discharge of hot gases through the
38. The draught produced by chimney of given height chimney, the height of hot-gas column producing
at given outside temperature draught is
668 POWER PLANT ENGINEERING
G G
p n1 p n1
(c) there is enthalpy drop in nozzles
(c) 2 (d) 2
p1 H n 1K p1 H n 1K .
(d) none of the above.
51. The isentropic expansion of steam through nozzle 59. De Laval turbine is
for the steam initially superheated at inlet is (a) pressure compounded impulse turbine
approximated by equation (b) velocity compounded impulse turbine
(a) pv1.3 = C (b) pv1.125 = C (c) simple single wheel impulse turbine
1.4
(c) pv = C (d) pv = C. (d) simple single wheel reaction turbine.
52. The ratio of exit pressure to inlet pressure for 60. The pressure on the two sides of the impulse wheel
maximum mass flow rate per unit area of steam of a steam turbine
through a nozzle when steam is initially dry
(a) is same (b) is different
saturated is
(c) increases from one side to the other side
(a) 0.6 (b) 0.578
(d) decreases from one side to the other side.
(c) 0.555 (d) 0.5457.
61. In De Laval steam turbine
53. The ratio of exit pressure to inlet pressure for (a) the pressure in the turbine rotor is
maximum mass flow rate per unit area of steam approximately same as in condenser
through nozzle when steam is initially
(b) the pressure in the turbine rotor is higher than
superheated is
pressure in the condenser
(a) 0.555 (b) 0.578
(c) the pressure in the turbine rotor gradually
(c) 0.5457 (d) 0.6. decreases from inlet to exit to condenser
54. The critical pressure ratio of a convergent nozzle is (d) none of the above.
defined as
62. In case of reaction steam turbine
(a) the ratio of outlet pressure to inlet pressure of
(a) there is enthalpy drop both in fixed and moving
nozzle
blades
(b) the ratio of inlet pressure to outlet pressure of
(b) there is enthalpy drop only in fixed blades
nozzle
(c) there is enthalpy drop only in moving blades
(c) the ratio of outlet pressure to inlet pressure only
(d) none of the above.
when mass flow rate per unit area is minimum
63. Curtis turbine is
(d) the ratio of outlet pressure to inlet pressure only
when mass flow rate per unit is maximum. (a) reaction steam turbine
55. The isentropic expansion of steam through nozzle (b) pressure-velocity compounded steam turbine
for the steam initially dry saturated at inlet is (c) pressure compounded impulse steam turbine
approximated by equation (d) velocity compounded impulse steam turbine.
OBJECTIVE TYPE QUESTIONS BANK 669
64. Rateau steam turbine is (c) initial pressure and temperature only
(a) reaction steam turbine (d) all of the above.
(b) velocity compounded impulse steam turbine 74. For multistage steam turbine, reheat factor is
(c) pressure compounded impulse steam turbine defined as
(d) pressure-velocity compounded steam turbine. (a) stage efficiency × nozzle efficiency
65. Parson’s turbine is (b) cumulative enthalpy drop × nozzle
(a) pressure compounded steam turbine cumulative enthalpy drop
(c)
(b) simple single wheel, impulse steam turbine isentropic enthalpy drop
(c) simple single wheel reaction steam turbine isentropic enthalpy drop
(d) .
(d) multi-wheel reaction steam turbine. cumulative actual enthalpy drop
66. Blade or diagram efficiency is given by 75. The value of reheat factor normally varies from
(a) 0.5 to 0.6 (b) 0.9 to 0.95
(C Cw0 ) Cbl 2Cbl (Cw1 Cw0 )
(a) w1 (b) (c) 1.02 to 1.06 (d) 1.2 to 1.6.
C1 C12
76. Steam turbines are governed by which of the
C 2 C2 C 2 following methods ?
(c) bl2 (d) 1 2 0 .
C1 C1 (a) Throttle governing
67. Axial thrust on rotor of steam turbine is (b) Nozzle control governing
(a) m s (Cf Cf ) s2 (Cf 2Cf )
(b) m (c) By pass governing
1 0 1 0
(d) All of the above.
(c) m
s (Cf Cf ) s (2Cf Cf ) .
(d) m
1 0 1 0 77. In steam turbines the reheat factor
68. Stage efficiency of steam turbine is (a) increases with the increase in number of stages
(a) blade/nozzle (b) nozzle/blade (b) decreases with the increase in number of stages
(c) nozzle × blade (d) none of the above. (c) remains same irrespective of number of stages
69. For maximum blade efficiency for single stage (d) none of the above.
impulse turbine 78. The thermal efficiency of the engine with condenser
F C I = cos
H C JK
(a) G bl 2 as compared to without condenser, for a given
(b) = cos
1
pressure and temperature of steam, is
(a) higher
cos cos2
(c) = (d) = . (b) lower
2 2
(c) same as long as initial pressure and temperature
70. Degree of reaction as referred to steam turbine is
is unchanged
defined as
(d) none of the above.
hf hm
(a) (b) 79. In Jet type condensers
hm hf
(a) cooling water passes through tubes and steam
hm hf surrounds them
(c) (d) .
hm hf hf hm (b) steam passes through tubes and cooling water
71. For Parson’s reaction steam turbine, degree of surrounds them
reaction is (c) steam and cooling water mix
(a) 75% (b) 100% (d) steam and cooling water do not mix.
(c) 50% (d) 60%. 80. In a shell and tube surface condenser
72. The maximum efficiency for Parson’s reaction (a) steam and cooling water mix to give the
turbine is given by condensate
cos 2 cos (b) cooling water passes through the tubes and
(a) max = (b) max = steam surrounds them
1 cos 1 cos
(c) steam passes through the cooling tubes and
2 cos2 1 cos2 cooling water surrounds them
(c) max = (d) max = .
1 cos2 2 cos2 (d) all of the above varying with situation.
73. Reheat factor in steam turbines depends on 81. In a surface condenser if air is removed, there is
(a) exit pressure only (a) fall in absolute pressure maintained in condenser
(b) stage efficiency only (b) rise in absolute pressure maintained in condenser
670 POWER PLANT ENGINEERING
(c) no change in absolute pressure in the condenser 87. Evaporative type of condenser has
(d) rise in temperature of condensed steam. (a) steam in pipes surrounded by water
82. The cooling section in the surface condenser (b) water in pipes surrounded by steam
(a) increases the quantity of vapour extracted along (c) either (a) or (b)
with air (d) none of the above.
(b) reduces the quantity of vapour extracted along 88. Condenser efficiency is defined as
with air saturation temperature at condenser pressure
(c) does not affect vapour quantity extracted but (a)
rise in cooling water temperature
reduces pump capacity of air extraction pump
temperature rise of cooling water
(d) none of the above. (b)
saturation temperature corresponding
83. Edward’s air pump
to condenser pressure
(a) removes air and also vapour from condenser
temperature rise of cooling water
(b) removes only air from condenser (c)
saturation temperature corresponding to
(c) removes only un-condensed vapour from
condenser condenser pressure - cooling
(d) removes air alongwith vapour and also the water inlet temperature
condensed water from condenser. saturation temperature corresponding
84. Vacuum efficiency of a condenser is ratio of to condenser pressure
(d) .
actual vacuum in condenser saturation temperature of vapour at
with air present its partial pressure in condenser
(a) 89. Pipes carrying steam are generally made up of
theoretical vacuum in condenser
with no air present (a) steel (b) cast iron
(c) copper (d) aluminium.
theoretical vacuum in condenser
90. For the safety of a steam boiler the number of safety
with no air present valves fitted are
(b)
actual vacuum in condenser (a) four (b) three
with air present (c) two (d) one.
partial pressure of vapour + partial 91. Steam turbines commonly used in steam power
pressure of air present station are
(c) (a) condensing type
partial pressure of vapour only
(b) non-condensing type
partial pressure of vapour only (c) none of the above.
(d) .
partial pressure of vapour + partial 92. Belt conveyor can be used to transport coal at
pressure of air pressure inclinations upto
85. In a steam power plant the function of a condenser is (a) 30° (b) 60°
(a) to maintain pressure below atmospheric to (c) 80° (d) 90°.
increase work output from the prime mover 93. The maximum length of a screw conveyor is about
(b) to receive large volumes of steam exhausted from (a) 30 metres (b) 40 metres
steam prime mover (c) 60 metres (d) 100 metres.
(c) to condense large volumes of steam to water 94. The efficiency of a modern boiler using coal and heat
which may be used again in boiler recovery equipment is about
(d) all of the above. (a) 25 to 30% (b) 40 to 50%
86. In a regenerative surface condenser (c) 65 to 70% (d) 85 to 90%.
(a) there is one pump to remove air and condensate 95. The average ash content in Indian coals is about
(b) there are two pumps to remove air and (a) 5% (b) 10%
condensate (c) 15% (d) 20%.
(c) there are three pumps to remove air, vapour and 96. Load centre in a power station is
condensate (a) centre of coal fields
(d) there is no pump, the condensate gets removed (b) centre of maximum load of equipments
by gravity. (c) centre of gravity of electrical system.
OBJECTIVE TYPE QUESTIONS BANK 671
97. Steam pressure in a steam power station, which is 106. Presence of sulphur in coal will result in
usually kept now-a-days is of the order of (a) corroding air heaters
(a) 20 kgf/cm2 (b) 50 kgf/cm2 (b) spontaneous combustion during coal storage
(c) 100 kgf/cm 2 (d) 150 kgf/cm2. (c) causing clinkering and slagging
98. Economisers improve boiler efficiency by (d) facilitating ash precipitation
(a) 1 to 5% (b) 4 to 10%
(e) all of the above.
(c) 10 to 12% (d) 15 to 20%.
107. Pulverised fuel is used for
99. In steam power station, the choice of high
(a) saving fuel
temperature steam is for
(b) better burning
(a) increasing the efficiency of boiler alone
(b) increasing the efficiency of turbine alone (c) obtaining more heat.
(c) increasing overall efficiency 108. Combustible elements in the fuel are
(d) none of the above. (a) carbon and hydrogen
100. Location of centre of gravity (c.g.) of any electrical (b) carbon, hydrogen and sulphur
distribution system is determined as (c) carbon, hydrogen and nitrogen
total loading (electrical) (d) carbon, hydrogen and ash.
(a) c.g. =
sum of moments about two axes 109. Heating value of diesel oil is about
sum of moments about two axes (a) 5000 kcal/kg (b) 7000 kcal/kg
(b) c.g. =
total loading (c) 9000 kcal/kg (d) 11000 kcal/kg.
(c) c.g. = sum of moments × total loading 110. Higher calorific value (H.C.V.) is the heating value
(d) c.g. = sum of moments × (total loading)2. of fuel
101. Capacity of turbine and generator are related as (a) without water vapour which are formed by
generator kW combustion
(a) Turbine kW = (b) with water vapour which are formed by
generator efficiency
combustion
(b) Turbine kW = generator kW × generator
efficiency (c) none of the above.
(c) Turbine kW = generator kW 111. Which one is essential for combustion of fuel ?
(d) Turbine kW = (generator kW)2. (a) oxygen to support combustion
102. The capacity of large turbo-generators varies from (b) correct fuel air ratio
(a) 20 to 100 MW (b) 50 to 300 MW (c) proper ignition temperature
(c) 70 to 400 MW (d) 100 to 650 MW. (d) all the three above.
103. Caking coals are those which 112. Ultimate analysis of fuel is determination of
(a) burn completely percentage of
(b) burn freely (a) total carbon by weight
(c) do not form ash (b) total carbon by weight unit weight of H2, O2, N2,
(d) form lumps or masses of coke. sulphur and ash
104. Primary air is that air which is used to (c) ash, volatile matter and moisture.
(a) reduce the flame length 113. Which of the following coals has the highest calorific
(b) increase the flame length value ?
(c) transport and dry the coal (a) Peat (b) Lignite
(d) provide air around burners for getting optimum (c) Bituminous (d) Anthracite coal.
combustion. 114. The proximate analysis of coal gives
105. Secondary air is the air used to (a) various chemical constituents, carbon, hydrogen,
(a) reduce the flame length oxygen and ash
(b) increase the flame length (b) fuel constituents as percentage by weight, of
(c) transport and dry the coal moisture, volatile, fixed carbon and ash
(d) provide air round the burners for getting (c) percentage by weight, of moisture, volatile
optimum combustion. matter, fixed carbon and ash.
672 POWER PLANT ENGINEERING
115. In coal preparation plant, magnetic separators are 127. Superheating of steam is desirable for
used to remove (a) increasing the efficiency of Rankine cycle
(a) dust (b) clinkers (b) reducing initial condensation losses
(c) iron particles (d) sand. (c) avoiding too high moisture in the last stage of
116. Load carrying capacity of belt conveyor is about turbine
(a) 20 to 40 tons/hr (b) 50 to 100 tons/hr (d) all of the above
(c) 100 to 150 tons/hr (d) 150 to 200 tons/hr. (e) none of the above.
117. Method which is commonly applied for unloading 128. Thermal efficiency of the steam plant is of the
the coal for small power plant is order of
(a) lift trucks (b) coal accelerators (a) 30% (b) 50%
(c) tower cranes (d) belt conveyor. (c) 60% (d) 80%.
118. Bucket elevators are used for 129. In a regenerative air preheater, the heat is
(a) carrying coal in horizontal direction transferred
(b) carrying coal in vertical direction (a) by direct mixing
(c) carrying coal in any direction. (b) by extracting some gas from the furnace
119. The amount of air which is supplied for complete (c) from heating an intermediate material and then
combustion is called heating the air from this material.
(a) primary air (b) secondary air 130. The height of chimney in a steam power plant is
(c) tertiary air. governed by
120. In ....... system fuel from a central pulverizing unit (a) flue gases quantity
is delivered to a burner and then to the various (b) the draught to be produced
burners (c) control of pollution.
(a) unit (b) central 131. In boilers, the feed water treatment is done mainly
(c) none of the above. for removing ...... troubles.
121. Underfeed stokers work best for ...... coals high in (a) corrosion (b) scale formation
volatile matter and with caking tendency (c) carry over (d) embrittlement
(a) anthracite (b) lignite (e) all of the above.
(c) semi-bituminous and bituminous. 132. Blowing down of boiler water is the process to
122. Example of overfeed type stoker is (a) reduce the boiler pressure
(a) chain grate (b) spreader (b) increase the steam temperature
(c) travelling grate (d) all of the above. (c) control the solid concentration in the boiler water
123. Where unpulverised coal has to be used and boiler by removing some of the concentrated saline
capacity is large, the stoker which is used is water.
(a) underfeed stoker (b) overfeed stoker 133. Deaerative heating is done to
(c) any. (a) heat the water
124. Travelling grate stokers can burn coals at the rates (b) heat the air in the water
of (c) remove dissolved gases in the water.
(a) 50–75 kg/m2 per hour 134. Reheat factor is the ratio of
(b) 75–100 kg/m2 per hour (a) isentropic heat drop to useful heat drop
(c) 100–150 kg/m2 per hour (b) adiabatic heat drop to isentropic heat drop
(d) 150–200 kg/m2 per hour. (c) cumulative actual enthalpy drop for all stages
125. Capacity of the underfeed stoker is of the order of to total isentropic enthalpy heat drop.
(a) 100 to 200 kg of coal burned per hour 135. The value of the reheat factor is of the order of
(b) 100 to 500 kg of coal burned per hour (a) 0.8 to 1.0 (b) 1.0 to 1.05
(c) 100 to 2000 kg of coal burned per hour (c) 1.1 to 1.5 (d) above 1.5.
(d) 100 to 4000 kg of coal burned per hour. 136. Compounding of steam turbine is done for
126. Economisers are usually used in boiler plant (a) reducing the work done
working above (b) increasing the rotor speed
(a) 30 kgf/cm2 (b) 50 kgf/cm2 (c) reducing the rotor speed
(c) 70 kgf/cm2 (d) 90 kgf/cm2. (d) balancing the turbine.
OBJECTIVE TYPE QUESTIONS BANK 673
137. Topping turbines are 148. The temperature of cooling water leaving the diesel
(a) low pressure condensing units engine should not be more than
(b) high pressure non-condensing units (a) 30°C (b) 40°C
(c) low pressure non-condensing units (c) 60°C (d) 80°C.
(d) high pressure condensing units. 149. Total cost of a diesel power plant per kW of installed
138. In throttle governing capacity is less than that of steam power plant by
(a) larger heat drop is available (a) 5 to 10% (b) 20 to 30%
(b) lesser heat drop is available (c) 40 to 50% (d) 70 to 80%.
(c) there no effect on heat drop. 150. The ratio of piston stroke to bore of cylinder for
139. The commonly used material of condenser tubes is internal combustion engines varies between
(a) aluminium (b) cast iron (a) 0.9 to 1.9 (b) 0.5 to 0.8
(c) admiralty brass (d) mild steel. (c) 0.3 to 0.6 (d) 0.1 to 0.2.
140. The blades of impulse turbine are 151. Air fuel rate required for the combustion in diesel
engine is about
(a) symmetrically shaped around the centre line
(a) 5 : 1 (b) 10 : 1
(b) asymmetrically shaped around the centre line
(c) none of the above. (c) 15 : 1 (d) none of the above.
141. For medium and large size turbines the ...... 152. In multicylinder engines a particular sequence in
governing is used. the firing order is necessary
(a) throttle (a) to provide the best engine performance
(b) nozzle control (b) to obtain uniform turning moment
(c) by pass (c) to operate the ignition system smoothly
(d) to obtain non-uniform turning moment.
(d) combination of (a), (b), (c).
153. Most high speed diesel engines work on
142. Function of air pump in condenser is to
(a) Diesel cycle (b) Carnot cycle
(a) remove water (b) maintain vacuum
(c) maintain atmospheric pressure. (c) Dual combustion cycle (d) Otto cycle.
143. Wet air pump removes 154. In case of diesel engine, the pressure at the end of
compression is in the range of
(a) air only (b) only condensate
(a) 7–8 kgf/cm2 (b) 20–25 kgf/cm2
(c) both air and condensate.
(c) 35–40 kgf/cm2 (d) 50–60 kgf/cm2.
DIESEL POWER STATION 155. Reciprocating motion of the piston is converted into
a rotary one by
144. In diesel cycle
(a) connecting rod (b) crank shaft
(a) compression ratio and expansion ratio are equal
(c) crank web (d) gudgeon pin.
(b) compression ratio is greater than expansion ratio
156. Maximum temperature which is developed in the
(c) compression ratio is less than expansion ratio cylinder of a diesel engine is of the order of
(d) compression ratio = (expansion ratio)2. (a) 1000–1500°C (b) 1500–2000°C
145. Compression ratio of an I.C. engine is the ratio of (c) 2000–2500°C (d) 2500–3000°C.
total volume total volume 157. In a four-stroke cycle engine, the four operations
(a) (b)
swept volume clearance volume namely suction, compression, expansion and
(c) either of the above (d) none of the above. exhaust are completed in the number of revolutions
146. In a diesel engine the heat lost to the cooling water is of crank shaft equal to
(a) 10% (b) 20% (a) four (b) three
(c) 30% (d) 70%. (c) two (d) one.
147. The mechanical efficiency of a diesel engine is 158. In a two-stroke cycle engine, the operations namely
defined as suction, compression, expansion and exhaust are
B.H.P. I.H.P. completed in the number of revolutions of crank
(a) (b) shaft equal to
I.H.P. B.H.P.
(B.H.P.)2 (a) four (b) three
(c) B.H.P. × I.H.P. (d) . (c) two (d) one.
I.H.P.
674 POWER PLANT ENGINEERING
159. In a four stroke cycle S.I. engine the cam shaft runs (c) same for same power output
(a) at the same speed as crank shaft (d) same for same speed.
(b) at half the speed of crank shaft 169. Compression ratio of petrol engines is in the range of
(c) at twice the speed of crank shaft (a) 2 to 3 (b) 7 to 10
(d) at any speed irrespective of crank shaft speed. (c) 16 to 20 (d) none of the above.
160. The following is an S.I. engine. 170. Compression ratio of diesel engines may have a
(a) Diesel engine (b) Petrol engine range
(c) Gas engine (d) None of the above. (a) 8 to 10 (b) 10 to 15
161. The following is C.I. engine. (c) 16 to 20 (d) none of the above.
(a) Diesel engine (b) Petrol engine 171. The thermal efficiency of good I.C. engine at the
rated load is in the range of
(c) Gas engine (d) None of the above.
(a) 80 to 90% (b) 60 to 70%
162. In a four stroke cycle petrol engine, during suction
(c) 30 to 35% (d) 10 to 20%.
stroke
172. In case of S.I. engine, to have best thermal efficiency
(a) only air is sucked in
the fuel-air mixture ratio should be
(b) only petrol is sucked in
(a) lean (b) rich
(c) mixture of petrol and air is sucked in
(c) may be lean or rich (d) chemically correct.
(d) none of the above.
173. The fuel-air ratio, for maximum power of S.I.
163. In a four stroke cycle diesel engine, during suction engines, should be
stroke
(a) lean (b) rich
(a) only air is sucked in (c) may be lean or rich (d) chemically correct.
(b) only fuel is sucked in 174. In case of petrol engine, at starting
(c) mixture of fuel and air is sucked in (a) rich fuel-air ratio is needed
(d) none of the above. (b) weak fuel-air ratio is needed
164. The two stroke cycle engine has (c) chemically correct fuel-air ratio is needed
(a) one suction valve and one exhaust valve operated (d) any fuel-air ratio will do.
by one cam
175. Carburettor is used for
(b) one suction valve and one exhaust valve operated (a) S.I. engines (b) gas engines
by two cams
(c) C.I. engines (d) none of the above.
(c) only ports covered and uncovered by piston to
176. Fuel injector is used in
effect charging and exhausting
(a) S.I. engines (b) gas engines
(d) none of the above.
(c) C.I. engines (d) none of the above.
165. For same output, same speed and same compression
ratio the thermal efficiency of a two stroke cycle 177. Very high speed engines are generally
petrol engine as compared to that for four stroke (a) gas engines (b) S.I. engines
cycle petrol engine is (c) C.I. engines (d) steam engines.
(a) more (b) less 178. In S.I. engine, to develop high voltage for spark plug
(c) same as long as compression ratio is same (a) battery is installed
(d) same as long as output is same. (b) distributor is installed
166. The ratio of brake power to indicated power of an (c) carburettor is installed
I.C. engine is called (d) ignition coil is installed.
(a) mechanical efficiency (b) thermal efficiency 179. In S.I. engine, to obtain required firing order
(c) volumetric efficiency (d) relative efficiency. (a) battery is installed
167. The specific fuel consumption of a diesel engine as (b) distributor is installed
compared to that for petrol engine is (c) carburettor is installed
(a) lower (b) higher (d) ignition coil is installed.
(c) same for same output (d) none of the above. 180. For petrol engines the method of governing
168. The thermal efficiency of petrol engine as compared employed is
to diesel engine is (a) quantity governing (b) quality governing
(a) lower (b) higher (c) hit and miss governing (d) none of the above.
OBJECTIVE TYPE QUESTIONS BANK 675
181. For diesel engines the method of governing employed (c) fuel-air ratio is made rich
is (d) fuel-air ratio is made lean.
(a) quantity governing 191. The ignition quality of fuels for S.I. engines is
(b) quality governing determined by
(c) hit and miss governing (a) cetane number rating (b) octane number rating
(d) none of the above. (c) calorific value rating (d) volatility of the fuel.
182. Voltage developed to strike spark in the spark plug 192. Petrol commercially available in India for Indian
is in the range passenger cars has octane number in the range
(a) 6 to 12 volts (b) 1000 to 2000 volts (a) 40 to 50 (b) 60 to 70
(c) 20000 to 25000 volts (d) none of the above. (c) 80 to 85 (d) 95 to 100.
183. In a 4-cylinder petrol engine the standard firing 193. Octane number of the fuel used commercially for
order is diesel engine in India is in the range
(a) 1-2-3-4 (b) 1-4-3-2 (a) 80 to 90 (b) 60 to 80
(c) 1-3-2-4 (d) 1-3-4-2. (c) 60 to 70 (d) 40 to 45.
184. The torque developed by the engine is maximum 194. The knocking tendency in C.I. engines increases
(a) at minimum speed of engine with
(b) at maximum speed of engine (a) decrease of compression ratio
(c) at maximum volumetric efficiency speed of engine (b) increase of compression ratio
(d) at maximum power speed of engine. (c) increasing the temperature of inlet air
185. Iso-octane content in a fuel for S.I. engines (d) increasing cooling water temperature.
(a) retards auto-ignition 195. If petrol is used in a diesel engine, then
(b) accelerates auto-ignition (a) low power will be produced
(c) does not affect auto-ignition (b) efficiency will be low
(d) none of the above. (c) black smoke will be produced
186. Normal heptane content in fuel for S.I. engines (d) higher knocking will occur.
(a) retards auto-ignition
(b) accelerates auto-ignition
GAS TURBINE POWER PLANT
(c) does not affect auto-ignition 196. Thermal efficiency of a gas turbine plant as
(d) none of the above. compared to diesel engine plant is
187. The knocking in S.I. engines increases with (a) higher (b) lower
(a) increase in inlet air temperature (c) same
(b) increase in compression ratio (d) may be higher or lower.
(c) increase in cooling water temperature 197. Mechanical efficiency of a gas turbine as compared
(d) all of the above. to internal combustion reciprocating engine is
188. The knocking in S.I. engines gets reduced (a) higher (b) lower
(a) by increasing the compression ratio (c) same (d) un-predictable.
(b) by retarding the spark advance 198. For a gas turbine the pressure ratio may be in the
range
(c) by increasing inlet air temperature
(a) 2 to 3 (b) 3 to 5
(d) by increasing the cooling water temperature.
(c) 16 to 18 (d) 18 to 22.
189. Increasing the compression ratio in S.I. engines
199. The air standard efficiency of closed gas turbine cycle
(a) increases the tendency for knocking
is given by (rp = pressure ratio for the compressor
(b) decreases tendency for knocking and turbine)
(c) does not affect knocking 1
(d) none of the above. (a) = 1 – (b) = 1 – (rp)–1
(rp ) 1
190. The knocking tendency in petrol engines will
F 1I
1
increase when 1
(c) = 1 – G J (d) = (rp )
– 1.
(a) speed is decreased
(b) speed is increased
Hr Kp
676 POWER PLANT ENGINEERING
200. A closed cycle gas turbine works on 209. For starting gas turbine, the turbine rotor is usually
(a) Carnot cycle (b) Rankine cycle motored upto ‘coming in’ speed which is equal to
(c) Joule cycle (d) Atkinson cycle. (a) rated speed of the gas turbine
201. Thermal efficiency of closed cycle gas turbine plant (b) half of the rated speed of the gas turbine
increases by (c) no relation with speed of the turbine.
(a) reheating (b) intercooling 210. The blades of the gas turbine rotor are made of
(c) regenerator (d) all of the above. (a) carbon steel
202. With the increase in pressure ratio thermal (b) stainless steel
efficiency of a simple gas turbine plant with fixed (c) high alloy steel
turbine inlet temperature
(d) high nickel alloy (Nimic 80).
(a) decreases
211. Maximum temperature in a gas turbine is of the
(b) increases
order of
(c) first increases and then decreases
(a) 700°C (b) 900°C
(d) first decreases and then increases.
(c) 1600°C (d) 2100°C.
203. The thermal efficiency of a gas turbine cycle with
212. In gas turbines, high thermal efficiency is obtained
ideal regenerative heat exchanger is
in
(a) equal to work ratio (b) less than work ratio
(a) closed cycle (b) open cycle
(c) more than work ratio (d) unpredictable.
(c) in both the cycles.
204. In a two stage gas turbine plant reheating after first
213. In a gas turbine plant, a regenerator increases
stage
(a) decreases thermal efficiency (a) work output (b) pressure ratio
(b) increases thermal efficiency (c) thermal efficiency (d) none of the above.
(c) does not affect thermal efficiency 214. Maximum combustion pressure in a gas turbine is
...... as compared to diesel engine.
(d) none of the above.
(a) same (b) less
205. In a two stage gas turbine plant reheating after first
stage (c) more.
(a) increases work ratio 215. Capital cost of a gas turbine plant is ...... than that
of a steam power plant of same capacity
(b) decreases work ratio
(a) same (b) lower
(c) does not affect work ratio
(c) higher.
(d) none of the above.
206. In a two stage gas turbine plant, with intercooling
HYDRO-ELECTRIC POWER PLANTS
and reheating
(a) both work ratio and thermal efficiency improve 216. Pelton turbines are mostly
(b) work ratio improves but thermal efficiency (a) horizontal (b) vertical
decreases (c) inclined.
(c) thermal efficiency improves but work ratio 217. The annual depreciation of a hydropower plant is
decreases about
(d) both work ratio and thermal efficiency decrease. (a) 0.5 to 1.5% (b) 10 to 15%
207. For a jet propulsion unit, ideally the compressor (c) 15 to 20% (d) 20 to 25%.
work and turbine work are 218. The power output from a hydro-electric power plants
(a) equal depends on three parameters
(b) unequal (a) head, type of dam and discharge
(c) not related to each other (b) head, discharge and efficiency of the system
(d) unpredictable. (c) efficiency of the system, type of draft tube and
208. Greater the difference between jet velocity and type of turbine used
aeroplane velocity (d) type of dam, discharge and type of catchment
(a) greater the propulsive efficiency area.
(b) less the propulsive efficiency 219. Water hammer is developed in
(c) unaffected is the propulsive efficiency (a) penstock (b) draft tube
(d) none of the above. (c) turbine (d) surge tank.
OBJECTIVE TYPE QUESTIONS BANK 677
220. The function of a surge tank is 231. Francis turbine is usually used for
(a) to supply water at constant pressure (a) low head installation upto 30 m
(b) to produce surges in the pipe line (b) medium head installation from 30 to 180 m
(c) to relieve water hammer pressures in the (c) high head installation above 180 m
penstock pipe. (d) for all heads.
221. Gross head of a hydropower station is 232. In Francis turbine runner, the number of blades is
(a) the difference of water level between the level generally of the order of
in the storage and tail race (a) 1–2 (b) 4–6
(b) the height of the water level in the river where (c) 6–8 (d) 12–16.
the storage is provided 233. Francis, Kaplan and propeller turbines fall under
(c) the height of the water level in the river where the category of
tail race is provided. (a) impulse turbine
222. Operating charges are minimum in the case of ...... (b) reaction turbine
for same power output.
(c) impulse reaction combined
(a) gas turbine plant (b) hydel plant
(d) axial flow.
(c) thermal plant (d) nuclear plant.
234. The specific speed (NS) of the turbine is given by
223. Location of the surge tank in a hydro-electric station
is near to the N P N P
(a) NS = (b) NS =
(a) tailrace (b) turbine H 5/4 H 3/ 4
(c) reservoir. N P N P
(c) NS = 3/2
(d) NS = .
224. Pelton wheel turbine is used for minimum of the H H 2/3
following heads 235. The expression for power output (P) in kW, of a
(a) 40 m (b) 120 m hydro-electric station is
(c) 180 m or above. QwH 0 0.736 QwH
(a) (b)
225. Running cost of a hydro-electric power plant is 0.736 75 75 0
(a) equal to running cost of a steam power plant 75 QwH 0 0.736 QwH 0
(c) (d) .
(b) less than running cost of a steam power plant 0.736 75
(c) more than running cost of a steam power plant.
NUCLEAR POWER STATIONS
226. The empirical relation for determination of number
of buckets (Z) for Pelton turbine in terms of jet ratio 236. The average thermal efficiency of a modern nuclear
(m) is given by power plant is about
(a) Z = 15 m + 0.5 (b) Z = 0.5 m + 15 (a) 30% (b) 40%
m (c) 60% (d) 80%.
(c) Z = + 15.
0.5 237. Reflectors of a nuclear reactor are made up of
227. Francis turbine is usually used for (a) boron (b) cast iron
(a) high heads (b) medium heads (c) beryllium (d) steel.
(c) low heads. 238. The function of a moderator in a nuclear reactor is
228. In high head hydro-power plant the velocity of water (a) to slow down the fast moving electrons
is pen stock is about (b) to speed up the slow moving electrons
(a) 1 m/s (b) 4 m/s (c) to start the chain reaction
(c) 7 m/s (d) 12 m/s. (d) to transfer heat produced inside the reactor to a
229. Pelton turbine is suitable for high head and heat exchanger.
(a) high discharge (b) low discharge 239. When a nuclear reactor is operating at constant
(c) both low and high discharge. power the multiplication factor is
230. In reaction turbine, function of the draft tube is (a) less than unity (b) greater than unity
(a) to increase the flow rate (c) equal to unity (d) none of the above.
(b) to reduce water hammer effect 240. The conversion ratio of a breeder reactor is
(c) to convert kinetic energy of water to potential (a) equal to unity (b) more than unity
energy by a gradual expansion in divergent part. (c) less than unity (d) none of the above.
678 POWER PLANT ENGINEERING
241. In the nuclear fission reactions ...... isotope of (a) stop chain reaction
uranium is used. (b) absorb neutrons
(a) U233 (b) U234 (c) reduce the speed of neutrons
(c) U .238
(d) reduce temperature.
242. Tarapur nuclear power plant has 253. Thermal shielding is provided to
(a) pressurised water reactors (a) protect the walls of the reactor from radiation
(b) boiling water reactors damage
(c) CANDU type reactors. (b) absorb the fast neutrons
243. Critical mass of fuel is the amount required to make (c) protect the operating personnel from exposure
the multiplication factor ...... unity. to radiation
(a) equal to (b) less than (d) (a), (b) and (c) above
(c) more than. (e) (b) and (c) both
244. The nuclear energy is measured as (f) none of the above.
(a) MeV (b) MW 254. A CANDU reactor uses
(c) Curie. (a) only fertile material
245. Fission chain reaction is possible when (b) highly enriched uranium (85% U235)
(a) fission produces the same number of neutrons (c) natural uranium as fuel and heavy water as
which are absorbed moderator and coolant.
(b) fission produces more neutrons than are 255. Fission of U235 releases ...... energy.
absorbed
(a) 200 MeV (b) 238 MeV
(c) fission produces less neutrons than are absorbed
(c) 431 MeV.
(d) none of the above.
256. Fast breed reactors are best suited for India because
246. In nuclear chain fission reaction, each neutron which
(a) of large thorium deposits
causes fission produces
(a) no new neutron (b) one new neutron (b) of large uranium deposits
(c) more than one new neutron. (c) of large plutonium deposits.
247. ...... is the most commonly used moderator. 257. India’s first nuclear power plant was started at
(a) Graphite (b) Sodium (a) Narora (U.P.)
(c) Deuterium (d) Any of the above. (b) Tarapur (Mumbai)
248. Which of the following are fertile materials (c) Kota (Rajasthan)
(a) U238 and Th239 (b) U238 and Th232 (d) Kalpakkam (Chennai).
233
(c) U and Pu 239 (d) U238 and Pu239.
POWER PLANT ECONOMICS
249. In a nuclear reactor the function of a reflector is to
(a) reduce the speed of the neutrons 258. Load factor of a power station is defined as
(b) stop the chain reaction (a) maximum demand/average load
(c) reflect the escaping neutrons back into the core. (b) average load × maximum demand
250. In gas cooled reactor (GCR) ...... are used as (c) average load/maximum demand
moderator and coolant respectively. (d) none of the above.
(a) heavy water and CO2 (b) graphite and air 259. Load factor of a power station is generally
(c) graphite and CO2 (d) none of the above. (a) equal to unity (b) less than unity
251. In a pressurised water reactor (PWR) (c) more than unity (d) none of the above.
(a) the coolant water is pressurised to work as 260. Diversity factor is always
moderator
(a) equal to unity (b) less than unity
(b) the coolant water boils in the core of the reactor
(c) more than unity (d) more than twenty.
(c) the coolant water is pressurised to prevent
boiling of water in the core 261. The load factor for heavy industries may be taken
as
(d) no moderator is used.
252. The function of the moderator in a nuclear reactor (a) 10 to 20% (b) 25 to 40%
is to (c) 50 to 70% (d) 70 to 80%.
OBJECTIVE TYPE QUESTIONS BANK 679
262. The load factor of domestic load is usually 273. In Hopkinson demand rate or two part tariff the
(a) 10 to 15% (b) 30 to 40% demand rate or fixed charges are
(c) 50 to 60% (d) 60 to 70%. (a) dependent upon the energy consumed
263. Annual depreciation cost is calculated by (b) dependent upon the maximum demand of the
(a) sinking fund method (b) straight line method consumer
(c) both (a) and (b) (d) estimate value. (c) both (a) and (b)
264. Depreciation charges are high in case of (d) none of the above.
(a) thermal plant (b) diesel plant
(c) hydro-electric plant (d) any of the above. NON-CONVENTIONAL POWER GENERATION
265. Demand factor is defined as 274. The function of a solar collector is to convert
(a) average load/maximum demand (a) solar energy into electricity
(b) maximum demand/connected load (b) solar energy into radiation
(c) connected load/maximum demand (c) solar energy into thermal energy.
(d) maximum demand × connected load.
275. Most of the solar radiation received on earth surface
266. High load factor indicates that lies within the range of
(a) cost of generation per unit power is increased (a) 0.2 to 0.4 microns
(b) total plant capacity is utilised for most of the (b) 0.38–0.78 microns
time
(c) 0–0.38 microns.
(c) total plant capacity is not properly utilised for
most of the time. 276. Flat plate collector absorbs
267. A load curve indicates (a) direct radiation only
(a) average power used during the period (b) diffuse radiation only
(b) average kWh (kW) energy consumption during (c) direct and diffuse both.
the period 277. Main applications of solar energy may be considered
(c) neither (a) nor (b). in the following categories
268. Approximate estimation of power demand can be (a) solar electric applications
made by the method/methods (b) fuel from biomass
(a) load survey method (b) statistical methods (c) direct thermal applications
(c) mathematical method (d) economic parameters (d) both (a) and (b)
(e) all of the above. (e) (a), (b) and (c).
269. Annual depreciation as per straight line method, is 278. Temperature attained by a flat-plate collector is of
calculated by the
(a) the capital cost divided by number of years of (a) order of about 90°C
life (b) range of 100°C to 150°C
(b) the capital cost minus the salvage value, is (c) above 150°C
divided by the number of years of life
(d) none of the above.
(c) investing a uniform sum of money per annum
at stipulated rate of interest. 279. A pyranometer is used for measurement of
270. A consumer has to pay lesser fixed charges in (a) direct radiation only
(a) flat rate tariff (b) two part tariff (b) diffuse radiation only
(c) maximum demand tariff. (c) direct as well as diffuse radiation.
271. In two part tariff, variation in load factor will affect 280. Sun tracking is needed in the case of ...... collector.
(a) fixed charges (a) flat plate
(b) operating or running charges (b) cylindrical parabolic and paraboloid.
(c) both (a) and (b). (c) both (a) and (b).
272. In India the tariff for charging the consumers for 281. In a solar collector the function of the transparent
the consumption of electricity is based on cover is to
(a) straight meter rate (a) transmit solar radiation only
(b) block meter rate (b) protect the collector from dust
(c) reverse form of block meter rate (c) decrease the heat loss from collector beneath to
(d) two part tariff. atmosphere.
680 POWER PLANT ENGINEERING
282. Temperature attained by cylindrical parabolic 295. Fuel cell is a device in which
collector is of the range of (a) chemical energy is converted into electricity
(a) 50 to 100°C (b) 100 to 150°C (b) heat energy is first converted into chemical
(c) 150 to 300°C (d) 300 to 500°C. energy
283. Most widely used material of a solar cell is (c) heat energy is converted into electricity.
(a) arsenic (b) cadmium 296. The nature of the current developed by MHD
(c) silicon (d) steel. generator is
284. Photovoltaic cell or solar cell converts (a) direct current (b) alternating current
(a) thermal energy into electricity (c) either direct or alternating.
(b) electromagnetic radiation directly into electricity 297. In MHD generators the conductor employed is
(c) solar radiation into thermal energy.
(a) gas (b) liquid metal
285. Maximum wind energy available is proportional to
(c) liquid metal or gas (d) none of the above.
(a) square of the diameter of rotor
298. Seeding material which is added with the working
(b) air density fluid in MHD generator is used for
(c) cube of the wind velocity
(a) decreasing the conductivity of the gas
(d) (a), (b) and (c).
(b) increasing the conductivity of the gas
286. ...... type of wind mill is of simple design.
(c) creating no effect on conductivity.
(a) Horizontal axis wind mill
299. Power output per unit volume of an MHD generator
(b) Vertical axis wind mill
is proportional to
(c) None.
(a) square of the magnetic flux density
287. Cost of wind energy generator compared to
conventional power plants for the same power (b) electrical conductivity of the gas
output is (c) square of the fluid velocity
(a) equal (b) lower (d) (a), (b) and (c).
(c) higher. 300. Biogas consists of
288. The turbine which is used in a tidal power plant for (a) only methane
getting continuous power is (b) methane and CO2 with some impurities
(a) simple impulse type (b) reversible type (c) a special organic gas
(c) propeller type.
(d) none of the above.
289. Largest geothermal plant in operation is in
301. The main byproduct of the biogas plant is
(a) Maxico (b) Italy
(a) biogas (b) bio-mass
(c) Russia (d) California.
(c) organic manure.
290. Geothermal plant is suitable for
302. Thermo-electric energy conversion is due to
(a) base load power (b) peak load power
(a) radiation (b) emission effect
(c) none.
291. A geothermal field may yield (c) thermal energy.
(a) hot water (b) wet steam 303. The working principle of thermo-electric generator
is based on the principle of
(c) dry steam (d) (a), (b) and (c).
292. Geothermal power plants as compared to fossil fuel (a) Hall (b) Seebeck
plants have ...... load factor. (c) Faraday.
(a) equal (b) lower 304. Materials which are employed for electrodes in
(c) higher. thermo-electric generators are of
293. Geothermal steam and hot water may contain (a) insulators (b) semiconductors
(a) NH3 (b) Na2S (c) metals (d) conductors.
(c) H2S, NH3 and radon gas. 305. Thermionic converter utilizes
294. Fuel cells have conversion efficiencies of the order of (a) Thermionic emission effect
(a) 20% (b) 30% (b) Pettier effect
(c) 50% (d) 70%. (c) Seebeck effect.
OBJECTIVE TYPE QUESTIONS BANK 681
ANSWERS
12. A normal working life of 100 years is estimated for 38. In burners, too much secondary air can cool the
wind mills. mixture and prevent its heating to ignition
13. The amount of excess air supplied varies with the temperature.
type of fuel and the firing conditions. 39. A turbulent burner is also called a long flame burner.
14. Total weight of carbon in one kg of flue gas is = (2/5 40. A wick burner is suitable for models or domestic
CO2 + 3/7 CO). appliances.
15. Electrical energy cannot be easily transported from 41. A fluidised bed may be defined as the bed of solid
one place to another. particles behaving as a fluid.
16. Power is primarily associated with mechanical work 42. The ‘collection efficiency’ of a dust collector is the
and electrical energy. amount of dust removed per unit weight of dust.
17. A chemical fuel does not release heat energy on 43. The small pressure difference which causes a flow
combustion. of gas to take place is termed as draught.
18. Liquid fuels are less advantageous in comparison 44. Forced draught is a negative pressure drop.
to solid fuels. 45. Steam jet draught is a simple and easy method of
19. The operating cost of an hydro-electric plant is very producing artificial draught.
high. 46. The boilers which produce steam at pressures of 20
20. When methane burns in the pressure of oxygen the bar and above called high pressure boilers.
combustion products are carbondioxide and water 47. The removal of the mud and other impurities of
vapours ? water from the lowest part of the boiler is termed
T T2 as ‘blowing off’.
21. Carnot cycle efficiency = 1 .
T2 48. Shell diameter of the Cochran boiler is about 15 m.
22. Carnot cycle gives the highest thermal efficiency. 49. Stirling water tube boiler is an example of bent tube
23. Industrial power plants are normally non- boiler.
condensing. 50. LaMont boiler works on a forced circulation and the
24. The cooling water supply to the condenser helps in circulation is maintained by a centrifugal pump,
maintaining a low pressure in it. driven by a steam turbine using steam from the
25. The power plant capacity can be determined by boiler.
studying the load duration curve and anticipated 51. Velox boiler makes use of pressurised combustion.
future demands. 52. The feed pump is used to heat the feed water.
26. A generator must operate economically at full load. 53. The function of an injector is to feed water into the
27. The consumption of steam per kWh decreases with boiler.
the increased pressure. 54. An economiser is a device in which the waste heat
28. A belt conveyor is very suitable means of of the flue gases it utilised for heating the feed water.
transporting small quantities of coal over small
55. The function of the air preheater is to decrease the
distances.
temperature of air before it enters the furnace.
29. Belt conveyor is not suitable for greater heights and
56. The function of a superheater is to increase the
short distances.
temperature of the steam above saturation
30. Flight conveyer requires little operational care. temperature.
31. A ‘stoker’ is a power operated fuel feeding mechanism 57. The function of a steam separator is to remove the
and grate. entrained water particles from the steam conveyed
32. In stoker firing cheap grade of fuel cannot be used. to the steam engine or turbine.
33. In case of overfeed stokers, the coal is fed into the 58. Feed water heating with steam at a lower pressure
grate above the point of air admission. than boiler pressure usually decreases overall plant
34. Spreader stokers can burn any type of coal. efficiency.
35. The underfeed principle is suitable for burning the 59. Jet type open heaters do not work well at low
semi-bituminous and bituminous coals. pressures, specially at sub-atmospheric pressure.
36. The amount of air which is used to carry the coal 60. For good performance feed water heaters must be
and to dry it before entering into the combustion drained and vented.
chamber is known as secondary air. 61. Factor of evaporation is defined as the ratio of heat
37. Coal is pulverised in order to increase its surface received by 1 kg of water under working conditions
exposure, thus promoting rapid combustion without to that received by 1 kg of water evaporated from
using large quantities of excess air. and at 0°C.
OBJECTIVE TYPE QUESTIONS BANK 683
62. If the boiler, economiser and superheater are 80. A jet condenser entails high manufacturing cost.
considered as a single unit, then the boiler efficiency 81. The vacuum efficiency is defined as the ratio of
is termed as overall efficiency of the boiler plant. maximum obtainable vacuum to actual vacuum.
63. Heat recovery equipment does not include 82. An air pump which removes the moist air alone is
economiser and superheater. called a dry air pump.
64. A steam nozzle may be defined as a passage of 83. In a cooling pond some spray or cooling devices are
varying cross-section, through which heat energy employed.
of steam is converted to pressure energy. 84. In a cooling tower water is made to trickle down
65. In a convergent-divergent nozzle, because of the drop by drop so that it comes in contact with the air
higher expansion ratio, addition of divergent portion moving in the opposite direction.
produces steam at higher velocities as compared to 85. In induced draught cooling towers the fans are
convergent nozzle. placed at the top of the tower and they draw the air
66. The steam turbine is a prime mover in which kinetic in through towers extending all around the tower
energy of steam is transformed into potential energy. at its base.
67. In an impulse turbine there is a gradual pressure 86. The formation of scale reduces heat transfer and
drop and takes place continuously over the fixed and simultaneously raises the temperature of the metal
moving blades. wall.
68. Velocity compounding method is used in Rateau and 87. Sodium carbonate is essentially responsible for the
Zoelly turbines. scale formation.
69. In general, optimum blade speed ratio () for 88. The carbondioxide is next to oxygen which is
maximum blade efficiency or maximum work done responsible for corrosion.
is given by 89. Water solids carried over in the steam leaving a
cos boiler drum are called “carry over”.
=
2n 90. Deposits on turbine blade increase the efficiency.
where, = nozzle angle 91. ‘Foaming’ is the weakening of boiler steel as a result
n = number of moving/rotating blade rows of inner crystalline cracks.
in series. 92. Coagulation is the process in which water is allowed
70. Velocity-compounded impulse turbine has high to stand at stand-still in big tanks so that solid
steam consumption and low efficiency. matter settles down.
71. The degree of reaction turbine stage is defined as 93. The process of removing dissolved oxygen is known
the ratio of heat drop over fixed blades to the total as deaeration.
heat drop in the stage. 94. Zeolites almost completely remove hardness but do
72. It is the overall or net efficiency that is meant when not reduce alkalinity or total solids.
the efficiency of a turbine is spoken of without 95. Demineralisation is often the most costly method of
qualification. producing make up water for high pressure boilers.
73. The efficiency of a steam turbine is considerably 96. pH value of water is the logarithm of the reciprocal
reduced if throttle governing is carried out at low of hydrogen ion concentration.
loads. 97. The steam pipes for high temperature application
74. Nozzle control can only be applied to reaction are manufactured from mild steel.
turbines. 98. Chromium improves corrosion and oxidation
75. A steam condenser is a device or an appliance in resistance.
which steam condenses and heat released by steam 99. The standby losses in diesel power plants are less.
is absorbed by water. 100. A diesel power plant can respond to varying load
76. In jet condensers the exhaust steam and water do without any difficulty.
not come in direct contact with each other. 101. The cost of building and civil engineering works in
77. In counter-flow type jet condenser the steam and case of diesel power plant is high.
cooling water enter the condenser from opposite 102. Any type of engine or machine which derives heat
directions. energy from the combustion of fuel or any other
78. Low level counter flow jet condenser is also called source and converts this energy into mechanical
barometric condenser. work is termed as a heat engine.
79. In an ejector condenser the exhaust steam and 103. In an I.C. engine the combustion of fuel takes place
cooling water mix in hollow truncated cones. outside the engine cylinder.
684 POWER PLANT ENGINEERING
104. The inside diameter of the cylinder is called bore. 129. Liquid fuels of petroleum origin such as distillate
105. The top most position of the piston towards cover oils or residual oils are most commonly used for gas
end side of the cylinder is called bottom dead centre. turbine plant.
106. The compression ratio is the ratio of total cylinder 130. Minerals like sodium, vanadium and calcium prove
volume to clearance volume. very harmful for turbine blading.
107. The average speed of the piston is called the piston 131. There exists an optimum pressure ratio producing
speed. maximum thermal efficiency for a given turbine inlet
temperature.
108. Spark plug is used in a diesel engine.
132. In a centrifugal compressor the capacity varies
109. Petrol engine is used in cars and motorcycles.
inversely as the speed ratio.
110. In a petrol engine the power is produced by
133. The centrifugal compressor is superior to the axial
compression ignition.
flow machine in that a high pressure ratio can be
111. Engines driving electrical generators have lower obtained in a short rugged single stage machine,
speeds and simple combustion chambers. though at the cost of lower efficiency and increased
112. In an I.C. engine the temperature of the gases inside frontal area.
the engine cylinder may vary from 35°C or less to 134. The primary function of the combustor is to provide
as high as 2750°C during the cycle. for the chemical reaction of the fuel and air being
113. The major short coming of thermo-syphon cooling supplied by the compressor.
is that cooling depends only on the temperature and 135. Free-piston engine plants are the conventional gas
is independent of the engine speed. turbine plants with the difference that the air
114. Lubrication is the admittance of oil between two compressor and combustion chamber are replaced
surfaces having no relative motion. by a free piston engine.
115. Splash system is used on some small 4-stroke 136. In an interconnected system the peak load is
stationary engines. supplied by hydropower when the maximum flow
116. Semi-pressure system of lubrication is a combination demand is less than the stream flow while steam
of splash and pressure systems. plant supplies the base.
117. Dry sump lubrication is generally adopted for high 137. The power plant should be set up near the load
capacity engine. centre.
118. Mist lubrication system is used for 4-stroke cycle 138. The whole area behind the dam draining into a
engines. stream or river across which the dam has been built
119. The compressed air system is commonly used for at a suitable placed is called ‘catchment area’.
starting large diesel engine employed for stationary 139. Water held in upstream reservoir is called pondage.
power plant service. 140. The water behind the dam at the plant is called
120. In general, lower the cetane number higher are the storage.
hydrocarbon emissions and noise level. 141. A weir is a low overflow dam across a stream for
121. Higher cetane rating of the fuel higher is the measuring flow or mountain water level, as at a lake
propensity for diesel knock. outlet.
122. Gas turbines are self-starting. 142. A dike is an embankment to confine water.
123. In almost all the fields open cycle gas turbine plants 143. A levee is a dike near the bank of a river to keep low
are used. land from overflowing.
124. A heat exchanger is usually used in large gas turbine 144. A buttress dam has a vertical upstream face.
unit for marine propulsion or industrial power. 145. An emergency spillway comes into action when the
125. The specific heat of helium at constant pressure is occurring flood discharge exceeds the designed flood
about two times that of air. discharge.
126. The main demerit associated with constant volume 146. A siphon spillway is designed on the principle of a
combustion turbines is that the pressure difference siphon.
and velocities of hot gases are not constant ; so the 147. A head race is a channel which conducts water from
turbine speed fluctuates. the wheels.
127. Natural gas is the ideal fuel for gas turbines, but 148. A canal is an open waterway evacuated in natural
this is not available everywhere. ground.
128. Blast furnace and producer gases cannot be used 149. A flume is a closed channel erected on the surface
for gas turbine power plant. or supported above ground on a trestle.
OBJECTIVE TYPE QUESTIONS BANK 685
150. A tunnel is an open channel excavated through a 172. In reaction turbines the runner utilizes both
natural obstruction. potential and kinetic energies.
151. A pipeline is a closed conduit usually supported on 173. In Francis turbine the ratio of width of the wheel to
or above the surface of the land. its diameter varies from 0.10 to 0.20.
152. A penstock is a closed conduit for supplying water 174. In Francis turbine the flow ratio varies from 0.4 to
under pressure to turbine. 0.6.
153. Open channels are generally very expensive. 175. In the Kaplan turbine the blades are adjustable.
154. Tunnels are generally the most costly type of 176. The runner of too low specific speed with low
conduits for a given length. available head increases the cost of generator due
155. Penstocks are used where the slope is too great for to the low turbine speed.
a canal. 177. An increase in specific speed of turbine is
156. Reinforced concrete penstocks are suitable upto accompanied by lower maximum efficiency and
5 m head. greater depth of excavation of the draft tube.
157. Steel penstocks can be designed for any head, with 178. The ratio of the volume of the water actually striking
the thickness varying with the pressure and the runner to the volume of water supplied to the
diameter. turbine is called volumetric efficiency.
158. Exposed penstocks last longer and are more 179. The cavitation effect cannot be reduced by polishing
accessible for inspection and maintenance. the surfaces.
159. Overflow surge tank is very satisfactory and 180. Spear regulation is satisfactory when a relatively
economical. large penstock feeds a small turbine and the
160. Inclined surge tank is more costlier than ordinary fluctuation of load is small.
type. 181. Hydrology is a science which deals with the
161. Restricted orifice surge tank is also called throttled depletion and replenishment of water resources.
surge tank. 182. Precipitation includes all the water that falls from
162. In a reaction turbine the pressure energy of water atmosphere to earth surface.
is converted into kinetic energy. 183. Transfer of water from liquid to vapour state is
163. The plants which cater for the base load of the called transpiration.
system are called base load plants. 184. Run-off can also be named as discharge or stream
164. Microhydel plants make use of standardised bulb flow.
sets with unit output ranging from 100 to 1000 kW 185. Hydrograph indicates the power available from the
working under heads between 1.5 to 10 metres. stream at different times of day, week or year.
165. A hydraulic turbine converts the potential energy 186. The basic concept of unit hydrograph is that the
of water into mechanical energy. hydrographs of run-off from two identical storms
166. The specific speed of a turbine is defined as the speed would not be same.
of a geometrically similar turbine that would develop 187. Flow duration curve is plotted between flow
one brake horsepower under a head of 2 metres. available during a period versus the fraction of time.
188. Flow duration curve cannot be used for preliminary
N Pt
167. Specific speed, Ns = studies.
H 3/ 4 189. The ‘firm power’ is also known as the ‘primary
where N = The normal working speed (r.p.m.) power’.
Pt = Power output of the turbine 190. A ‘mass curve’ is the graph of the cumulative values
H = The net or effective head (m). of water quantity (run off) against time.
168. Turbines with low specific speeds work under a high 191. The mass curve will always have a negative value.
head and low discharge condition. 192. Those pairs of atoms which have the same atomic
169. The Pelton wheel is a tangential flow impulse number and hence similar chemical properties but
turbine. different atomic mass number are called isotopes.
170. The hydraulic efficiency of a Pelton wheel is 193. Those atoms whose nuclei have the same number
maximum when the velocity of the wheel is 43 th the of neutrons are called isotones.
velocity of the jet of water at inlet. 194. The phenomenon of spontaneous emission of
171. In a Pelton wheel the angle of deflection of the jet powerful radiations exhibited by light elements is
through the buckets is taken as 120° if no angle of called radioactivity.
deflection is given. 195. Radioactive radiations are less penetrating.
686 POWER PLANT ENGINEERING
196. Prompt-fission gamma rays are produced as a result 221. Sodium-graphite reactor is one of the typical liquid
of the fissioning of a U235 (or other fissible material) metal reactor.
nucleus. 222. The specific power of a breeder reactor is very high.
197. Capture gamma rays are emitted by nucleus of an 223. The proportion of the fissible material in the fuel is
atom instantaneously upon the capture of a neutron. of considerable importance in determining the
198. The amount of mass defect is inversely proportional critical size of the reactor.
to the amount of energy released. 224. The capital cost of a nuclear power station is always
199. The intensity of emitted radiation is termed activity. high.
200. Half life represents the rate of decay of the 225. The maintenance cost of a nuclear power station is
radioactive isotopes. always low.
201. The mean life is twice half life. 226. The disposal of fission products is a big problem.
202. During a nuclear reaction, the charge in mass of 227. The main purpose of design and operation of the
the particle represents the release or an absorption plant is to bring out the cost of energy produced to
of energy. minimum.
203. When a fast moving neutron hits the U235 nucleus, connected load
the nucleus is excited and there is an emission of 228. Demand factor = .
gamma quantum. maximum demand
average load
204. When the nucleus is excited too much, it splits into 229. Load factor = .
four mostly equal masses. maximum demand
205. Cross-sections are measures of the probability that 230. Diversity factor
a given reaction will take place between a nucleus maximum demand of entire group
= .
or nuclei and incident radiation. sum of individual maximum demands
206. Fission is accompanied by the emission of neutrons 231. The utilisation factor is defined as the ratio of the
and gamma rays. maximum generator demand to the generator
207. The release of about 1.2 neutrons/fission makes it capacity.
possible to produce sustained fissioning. 232. Traction load includes electrical power need for
208. A chain reaction is that process in which the number pumps driven by electric motor to supply water to
of neutrons keeps on multiplying rapidly (in fields.
geometrical progression) during fission till whole of 233. The peak load indicated by the load curve/graph
the fissionable material is disintegrated. represents the maximum demand of the power
209. If K (multiplication factor) > 1, chain reaction cannot station.
be maintained. 234. The area under the load duration curve and the
210. The minimum quantity of fuel required for any corresponding chronological load curve is equal and
specific reactor system is called the ‘critical mass’. represents total energy delivered by the generating
211. ‘Nuclear fusion’ is the process of combining or fusing station.
two lighter nuclei into a stable and heavier nuclide. 235. Firm power may also be called prime power.
212. In heterogeneous reactor the fuel and moderator are 236. Hot reserve is that generating capacity which is not
mixed to form a homogeneous material. in operation but can be made available for the
213. Light water, heavy water and graphite are the most service.
common moderators used in reactors. 237. Spinning reserve is that reserve generating capacity
214. A breeder reactor converts fertile materials into which is connected to the bus and is ready to take
fissionable materials such as U238 and Th232 to Pu239 the load.
and U233 respectively besides the power production. 238. Interest is the difference between money borrowed
215. The reflector of the reactor consists of an assemblage and money returned.
of fuel elements, control rods and coolant. 239. Straight line method of calculating depreciation cost
216. In a nuclear reactor the function of a moderator is is most cumbersome and is rarely used.
to slow down the neutrons from high velocities. 240. Sinking fund method is based on the conception that
217. A reactor coolant should have high viscosity. the annual uniform deduction from income for
218. In a pressurised water reactor (PWR) water acts depreciation will accumulate to the capital value of
both as coolant as well as moderator. the plant at the end of the life of the plant or
219. In a boiling water reactor enriched fuel is used. equipment.
220. In a gas cooled reactor there is ample corrosion 241. Maintenance includes periodic cleaning, greasing,
problem. adjustments and overhauling of the equipment.
OBJECTIVE TYPE QUESTIONS BANK 687
242. As the capacity of the unit decreases there is a 263. By two-wire generators are meant such generators
corresponding reduction in floor space per kW. as have only two line terminals, one known as the
243. Primemovers used for industrial purpose should be positive terminal and the other as the negative
non-condensing so that steam after exhausting could terminal.
be used for processing. 264. An electrical generator is a machine which converts
244. As the capacity of diesel engines is limited therefore electrical energy into mechanical energy.
they are not suitable for bigger power stations. 265. The action of the cumulator is to reverse connections
245. Diesel power stations should be worked for to the external circuit simultaneously and at the
fluctuating loads or as standby. same instant the direction of e.m.f. reverses in each
246. Running of large sets for long periods at lower than of the coil sides.
maximum continuous rating decreases the cost of 266. The output e.m.f. of an electrical generator may be
unit generated. made less pulsating by using a small number of coils
247. The useful life of a power plant is that after which and cummutator segments.
repairs become so frequent and extensive that it is 267. The armature of a D.C. machines is built up of thin
found economical to replace the power plant by a laminations of low loss silicon steel.
new one. 268. In D.C. machines two layer winding with diamond
248. The useful life of a diesel power plant is about shaped coils is used.
70 years. 269. The use of copper brushes is made for machines
249. The fixed charges of a hydro-plant depend upon the designed for small currents at high voltages.
station output. 270. Box type brush holders are used in all ordinary D.C.
250. The general input-output may be represented as machines.
follows : 271. The differential compound generator is used as a
I = a + bL + cL2 + dL3 constant current generator for the same constant
current applications as the series generator.
where I = Input
272. The exciter is generally a series wound D.C.
L = Output
machine.
a, b, c and d = Constants.
273. The gaseous hydrogen is better cooling medium than
251. Incremental rate is defined as the ratio of additional air.
input required to increase additional output. 274. A transformer operates on the principle of mutual
252. Hopkinson demand rate method charges the inductance between two (and sometimes more)
consumer according to his maximum demand only. inductively coupled coils.
253. The main feature of the tidal cycle is the difference 275. One 3-phase transformer is costlier than three
in water surface elevations at the high tide and at single-phase transformers.
the low tide. 276. Three-phase transformers are much more difficult
254. Sedimentation and silteration of basins are the and costlier to repair than single-phase
problems associated with tidal power plants. transformers.
255. The solar farm consists of a whole field covered with 277. The switchgear constitutes all parts or equipments
parabolic trough concentrators. of the power plant whose function is to receive and
256. In case of ‘solar farm’ temperature at the point of distribute electric power.
focus can reach several thousand degrees celsius. 278. Fuses are used to protect circuits of very high
257. Geothermal energy is the heat from high pressure capacity against abnormal currents.
steam coming from within the earth. 279. The function of a circuit breaker is to break a circuit
258. The source of heat for a thermoelectric generator when various abnormal conditions arise and create
may be a small oil or gas burner, a radio-isotope or a danger for electrical equipment in an installation.
direct solar radiation. 280. Earthing provides improved lightning protection.
259. Work function is defined as the energy required to 281. Steel towers are rarely used.
extract an electron from the metal. 282. Poreclain has very good electrical characteristics as
260. A solar cell is much different from a photovoltaic well as high mechanical strength.
cell. 283. The substations serve as sources of energy supply
261. A solar cell is very costly. for local areas of distribution in which these are
262. MHD generator is a device which converts the heat located.
energy of a fuel directly into electrical energy 284. Pole-mounted substations are very costly.
without a conventional electric generator. 285. Some substations are simply switching stations.
688 POWER PLANT ENGINEERING
ANSWERS
A Coal, 2
analysis of, 2
Air preheater, 113 properties of, 3
Ash handling, 82 ranking of, 3
grading of, 3
B Cooling ponds and cooling towers, 164
Binary vapour cycle, 40 Cyclone burners, 77
Boilers, 97
Babcock and Wilcox, 103 D
boiler terms, 99 Diesel cycle, 48
classification of, 97 Diesel engine power plant, 218
Cochran, 100 advantages and disadvantages, 218
essentials of a good steam, 98 applications, 219
high pressure, 97, 105 essential components, 224
– Benson, 108 introduction, 218
– LaMont, 106 layout, 242
– Loeffler, 107 operation, 241
– Velox, 109 Diesel knock, 237
Lancashire, 101 Draft tubes, 333
Locomotive, 102 Dual combustion cycle, 50
performance of, 118 Dulong’s formula, 5
– boiler efficiency, 119 Dust collection, 85
– equivalent evaporation, 118
– evaporative capacity, 118 E
selection of, 98
simple vertical, 99 Economiser, 112
Striling, 104 Economics of power generation, 442
supercharged, 110 cost analysis, 445
supercritical, 109 economic load sharing, 454
Boilers Act (Indian), 187 location of power plant, 444
selection of equipment, 448
C terms and definitions, 442
Excess air, 9
Cetane number, 237
Chimney draught, 90 F
artificial draught, 93
natural draught, 90 Feed pumps, 111
Chimney height, 91 Feed water heaters, 115
Cinder catchers, 633 Feed water treatment, 176
689
690 POWER PLANT ENGINEERING
TABLE I
Saturated Water and Steam (Temperature) Tables
TABLE II
Saturated Water and Steam (Pressure) Tables
Absolute Temp. Specific enthalpy Specific entropy Specific volume
pressure (°C) (kJ/kg) (kJ/kg K) (m3/kg)
(bar)
p ts hf hfg hg sf sfg sg vf vg
0.006113 0.01 0.01 2 501.3 2 501.4 0.000 9.156 9.156 0.0010002 206.14
0.010 7.0 29.3 2 484.9 2 514.2 0.106 8.870 8.976 0.0010000 129.21
0.015 13.0 54.7 2 470.6 2 525.3 0.196 8.632 8.828 0.0010007 87.98
0.020 17.0 73.5 2 460.0 2 533.5 0.261 8.463 8.724 0.001001 67.00
0.025 21.1 88.5 2 451.6 2 540.1 0.312 8.331 8.643 0.001002 54.25
0.030 24.1 101.0 2 444.5 2 545.5 0.355 8.223 8.578 0.001003 45.67
0.035 26.7 111.9 2 438.4 2 550.3 0.391 8.132 8.523 0.001003 39.50
0.040 29.0 121.5 2 432.9 2 554.4 0.423 8.052 8.475 0.001004 34.80
0.045 31.0 130.0 2 428.2 2 558.2 0.451 7.982 8.433 0.001005 31.13
0.050 32.9 137.8 2 423.7 2 561.5 0.476 7.919 8.395 0.001005 28.19
0.055 34.6 144.9 2 419.6 2 565.5 0.500 7.861 8.361 0.001006 25.77
0.060 36.2 151.5 2 415.9 2 567.4 0.521 7.809 8.330 0.001006 23.74
0.065 37.6 157.7 2 412.4 2 570.1 0.541 7.761 8.302 0.001007 22.01
0.070 39.0 163.4 2 409.1 2 572.5 0.559 7.717 8.276 0.001007 20.53
0.075 40.3 168.8 2 406.0 2 574.8 0.576 7.675 8.251 0.001008 19.24
0.080 41.5 173.9 2 403.1 2 577.0 0.593 7.636 8.229 0.001008 18.10
0.085 42.7 178.7 2 400.3 2 579.0 0.608 7.599 8.207 0.001009 17.10
0.090 43.8 183.3 2 397.7 2 581.0 0.622 7.565 8.187 0.001009 16.20
0.095 44.8 187.7 2 395.2 2 582.9 0.636 7.532 8.168 0.001010 15.40
0.10 45.8 191.8 2 392.8 2 584.7 0.649 7.501 8.150 0.001010 14.67
0.11 47.7 199.7 2 388.3 2 588.0 0.674 7.453 8.117 0.001011 13.42
0.12 49.4 206.9 2 384.2 2 591.1 0.696 7.390 8.086 0.001012 12.36
0.13 51.0 213.7 2 380.2 2 593.9 0.717 7.341 8.058 0.001013 11.47
0.14 52.6 220.0 2 376.6 2 596.6 0.737 7.296 8.033 0.001013 10.69
0.15 54.0 226.0 2 373.2 2 599.2 0.754 9 7.254 4 8.009 3 0.001014 10.022
0.16 55.3 231.6 2 370.0 2 601.6 0.772 1 7.214 8 7.986 9 0.001015 9.433
0.17 56.6 236.9 2 366.9 2 603.8 0.788 3 7.177 5 7.965 8 0.001015 8.911
0.18 57.8 242.0 2 363.9 2 605.9 0.803 6 7.142 4 7.945 9 0.001016 8.445
0.19 59.0 246.8 2 361.1 2 607.9 0.818 2 7.109 0 7.927 2 0.001017 8.027
0.20 60.1 251.5 2 358.4 2 609.9 0.832 1 7.077 3 7.909 4 0.001017 7.650
0.21 61.1 255.9 2 355.8 2 611.7 0.845 3 7.047 2 7.892 5 0.001018 7.307
0.22 62.2 260.1 2 353.3 2 613.5 0.858 1 7.018 4 7.876 4 0.001018 6.995
0.23 63.1 264.2 2 350.9 2 615.2 0.870 2 6.990 8 7.861 1 0.001019 6.709
0.24 64.1 268.2 2 348.6 2 616.8 0.882 0 6.964 4 7.846 4 0.001019 6.447
STEAM TABLES AND MOLLIER DIAGRAM (vii)
0.25 65.0 272.0 2 346.4 2 618.3 0.893 2 6.939 1 7.832 3 0.001020 6.205
0.26 65.9 275.7 2 344.2 2 619.9 0.904 1 6.914 7 7.818 8 0.001020 5.980
0.27 66.7 279.2 2 342.1 2 621.3 0.914 6 6.891 2 7.805 8 0.001021 5.772
0.28 67.5 282.7 2 340.0 2 622.7 0.924 8 6.868 5 7.793 3 0.001021 5.579
0.29 68.3 286.0 2 338.1 2 624.1 0.934 6 6.846 6 7.781 2 0.001022 5.398
0.30 69.1 289.3 2 336.1 2 625.4 0.944 1 6.825 4 7.769 5 0.001022 5.229
0.32 70.6 295.5 2 332.4 2 628.0 0.962 3 6.785 0 7.747 4 0.001023 4.922
0.34 72.0 301.5 2 328.9 2 630.4 0.979 5 6.747 0 7.726 5 0.001024 4.650
0.36 73.4 307.1 2 325.5 2 632.6 0.995 8 6.711 1 7.707 0 0.001025 4.408
0.38 74.7 312.5 2 322.3 2 634.8 1.011 3 6.677 1 7.688 4 0.001026 4.190
0.40 75.9 317.7 2 319.2 2 636.9 1.026 1 6.644 8 7.670 9 0.001026 3.993
0.42 77.1 322.6 2 316.3 2 638.9 1.040 2 6.614 0 7.654 2 0.001027 3.815
0.44 78.2 327.3 2 313.4 2 640.7 1.053 7 6.584 6 7.638 3 0.001028 3.652
0.46 79.3 331.9 2 310.7 2 642.6 1.066 7 6.556 4 7.623 1 0.001029 3.503
0.48 80.3 336.3 2 308.0 2 644.3 1.079 2 6.529 4 7.608 6 0.001029 3.367
0.50 81.3 340.6 2 305.4 2 646.0 1.091 2 6.503 5 7.594 7 0.001030 3.240
0.55 83.7 350.6 2 299.3 2 649.9 1.119 4 6.442 8 7.562 3 0.001032 2.964
0.60 86.0 359.9 2 293.6 2 653.6 1.145 4 6.387 3 7.532 7 0.001033 2.732
0.65 88.0 368.6 2 288.3 2 656.9 1.169 6 6.336 0 7.505 5 0.001035 2.535
0.70 90.0 376.8 2 283.3 2 660.1 1.192 1 6.288 3 7.480 4 0.001036 2.369
0.75 92.0 384.5 2 278.6 2 663.0 1.213 1 6.243 9 7.457 0 0.001037 2.217
0.80 93.5 391.7 2 274.0 2 665.8 1.233 0 6.202 2 7.435 2 0.001039 2.087
0.85 95.1 398.6 2 269.8 2 668.4 1.251 8 6.162 9 7.414 7 0.001040 1.972
0.90 96.7 405.2 2 265.6 2 670.9 1.269 6 6.125 8 7.395 4 0.001041 1.869
0.95 98.2 411.5 2 261.7 2 673.2 1.286 5 6.090 6 7.377 1 0.001042 1.777
1.0 99.6 417.5 2 257.9 2 675.4 1.302 7 6.057 1 7.359 8 0.001043 1.694
1.1 102.3 428.8 2 250.8 2 679.6 1.333 0 5.994 7 7.327 7 0.001046 1.549
1.2 104.8 439.4 2 244.1 2 683.4 1.360 9 5.937 5 7.298 4 0.001048 1.428
1.3 107.1 449.2 2 237.8 2 687.0 1.386 8 5.884 7 7.271 5 0.001050 1.325
1.4 109.3 458.4 2 231.9 2 690.3 1.410 9 5.835 6 7.246 5 0.001051 1.236
1.5 111.3 467.1 2 226.2 2 693.4 1.433 6 5.789 8 7.233 4 0.001053 1.159
1.6 113.3 475.4 2 220.9 2 696.2 1.455 0 5.746 7 7.201 7 0.001055 1.091
1.7 115.2 483.2 2 215.7 2 699.0 1.475 2 5.706 1 7.181 3 0.001056 1.031
1.8 116.9 490.7 2 210.8 2 701.5 1.494 4 5.667 8 7.162 2 0.001058 0.977
1.9 118.6 497.8 2 206.1 2 704.0 1.512 7 5.631 4 7.144 0 0.001060 0.929
2.0 120.2 504.7 2 201.6 2 706.3 1.530 1 5.596 7 7.126 8 0.001061 0.885
2.1 121.8 511.3 2 197.2 2 708.5 1.546 8 5.563 7 7.110 5 0.001062 0.846
2.2 123.3 517.6 2 193.0 2 710.6 1.562 7 5.532 1 7.094 9 0.001064 0.810
2.3 124.7 523.7 2 188.9 2 712.6 1.578 1 5.501 9 7.080 0 0.001065 0.777
2.4 126.1 529.6 2 184.9 2 714.5 1.592 9 5.472 8 7.065 7 0.001066 0.746
(viii) POWER PLANT ENGINEERING
2.5 127.4 535.3 2 181.0 2 716.4 1.607 1 5.444 9 7.052 0 0.001068 0.718
2.6 128.7 540.9 2 177.3 2 718.2 1.620 9 5.418 0 7.038 9 0.001069 0.693
2.7 129.9 546.2 2 173.6 2 719.9 1.634 2 5.392 0 7.026 2 0.001070 0.668
2.8 131.2 551.4 2 170.1 2 721.5 1.647 1 5.367 0 7.014 0 0.001071 0.646
2.9 132.4 556.5 2 166.6 2 723.1 1.659 5 5.342 7 7.002 3 0.001072 0.625
3.0 133.5 561.4 2 163.2 2 724.7 1.671 6 5.319 3 6.990 9 0.001074 0.606
3.1 134.6 566.2 2 159.9 2 726.1 1.683 4 5.296 5 6.979 9 0.001075 0.587
3.2 135.7 570.9 2 156.7 2 727.6 1.694 8 5.274 4 6.969 2 0.001076 0.570
3.3 136.8 575.5 2 153.5 2 729.0 1.705 9 5.253 0 6.958 9 0.001077 0.554
3.4 137.8 579.9 2 150.4 2 730.3 1.716 8 5.232 2 6.948 9 0.001078 0.538
3.5 138.8 584.3 2 147.4 2 731.6 1.727 3 5.211 9 6.939 2 0.001079 0.524
3.6 139.8 588.5 2 144.4 2 732.9 1.737 6 5.192 1 6.929 7 0.001080 0.510
3.7 140.8 592.7 2 141.4 2 734.1 1.747 6 5.172 9 6.920 5 0.001081 0.497
3.8 141.8 596.8 2 138.6 2 735.3 1.757 4 5.154 1 6.911 6 0.001082 0.486
3.9 142.7 600.8 2 135.7 2 736.5 1.767 0 5.135 8 6.902 8 0.001083 0.473
4.0 143.6 604.7 2 133.0 2 737.6 1.776 4 5.117 9 6.894 3 0.001084 0.462
4.2 145.4 612.3 2 127.5 2 739.8 1.794 5 5.083 4 6.877 9 0.001086 0.441
4.4 147.1 619.6 2 122.3 2 741.9 1.812 0 5.050 3 6.862 3 0.001088 0.423
4.6 148.7 626.7 2 117.2 2 743.9 1.828 7 5.018 6 6.847 3 0.001089 0.405
4.8 150.3 633.5 2 112.2 2 745.7 1.844 8 4.988 1 6.832 9 0.001091 0.390
5.0 151.8 640.1 2 107.4 2 747.5 1.860 4 4.958 8 6.819 2 0.001093 0.375
5.2 153.3 646.5 2 102.7 2 749.3 1.875 4 4.930 6 6.805 9 0.001094 0.361
5.4 154.7 652.8 2 098.1 2 750.9 1.889 9 4.903 3 6.793 2 0.001096 0.348
5.6 156.2 658.8 2 093.7 2 752.5 1.904 0 4.876 9 6.780 9 0.001098 0.337
5.8 157.5 664.7 2 089.3 2 754.0 1.917 6 4.851 4 6.769 0 0.001099 0.326
6.0 158.8 670.4 2 085.0 2 755.5 1.930 8 4.826 7 6.757 5 0.001101 0.315
6.2 160.1 676.0 2 080.9 2 756.9 1.943 7 4.802 7 6.746 4 0.001102 0.306
6.4 161.4 681.5 2 076.8 2 758.2 1.956 2 4.779 4 6.735 6 0.001104 0.297
6.6 162.6 686.8 2 072.7 2 759.5 1.968 4 4.756 8 6.725 2 0.001105 0.288
6.8 163.8 692.0 2 068.8 2 760.8 1.980 2 4.734 8 6.715 0 0.001107 0.280
7.0 165.0 697.1 2 064.9 2 762.0 1.991 8 4.713 4 6.705 2 0.001108 0.273
7.2 166.1 702.0 2 061.1 2 763.2 2.003 1 4.692 5 6.695 6 0.001110 0.265
7.4 167.2 706.9 2 057.4 2 764.3 2.014 1 4.672 1 6.686 2 0.001111 0.258
7.6 168.3 711.7 2 053.7 2 765.4 2.024 9 4.652 2 6.677 1 0.001112 0.252
7.8 169.4 716.3 2 050.1 2 766.4 2.035 4 4.632 8 6.668 3 0.001114 0.246
8.0 170.4 720.9 2 046.5 2 767.5 2.045 7 4.613 9 6.659 6 0.001115 0.240
8.2 171.4 725.4 2 043.0 2 768.5 2.055 8 4.595 3 6.651 1 0.001116 0.235
8.4 172.4 729.9 2 039.6 2 769.4 2.065 7 4.577 2 6.642 9 0.001118 0.229
8.6 173.4 734.2 2 036.2 2 770.4 2.075 3 4.559 4 6.634 8 0.001119 0.224
8.8 174.4 738.5 2 032.8 2 771.3 2.084 8 4.542 1 6.626 9 0.001120 0.219
STEAM TABLES AND MOLLIER DIAGRAM (ix)
9.0 175.4 742.6 2 029.5 2 772.1 2.094 1 4.525 0 6.619 2 0.001121 0.215
9.2 176.3 746.8 2 026.2 2 773.0 2.103 3 4.508 3 6.611 6 0.001123 0.210
9.4 177.2 750.8 2 023.0 2 773.8 2.112 2 4.492 0 6.604 2 0.001124 0.206
9.6 178.1 754.8 2 019.8 2 774.6 2.121 0 4.475 9 6.596 9 0.001125 0.202
9.8 179.0 758.7 2 016.7 2 775.4 2.129 7 4.460 1 6.589 8 0.001126 0.198
10.0 179.9 762.6 2 013.6 2 776.2 2.138 2 4.444 6 6.582 8 0.001127 0.194
10.5 182.0 772.0 2 005.9 2 778.0 2.158 8 4.407 1 6.565 9 0.001130 0.185
11.0 184.1 781.1 1 998.5 2 779.7 2.178 6 4.371 1 6.549 7 0.001133 0.177
11.5 186.0 789.9 1 991.3 2 781.3 2.197 7 4.336 6 6.534 2 0.001136 0.170
12.0 188.0 798.4 1 984.3 2 782.7 2.216 1 4.303 3 6.519 4 0.001139 0.163
12.5 189.8 806.7 1 977.4 2 784.1 2.233 8 4.271 2 6.505 0 0.001141 0.157
13.0 191.6 814.7 1 970.7 2 785.4 2.251 0 4.240 3 6.491 3 0.001144 0.151
13.5 193.3 822.5 1 964.2 2 786.6 2.267 6 4.210 4 6.477 9 0.001146 0.146
14.0 195.0 830.1 1 957.7 2 787.8 2.283 7 4.181 4 6.465 1 0.001149 0.141
14.5 196.7 837.5 1 951.4 2 788.9 2.299 3 4.153 3 6.452 6 0.001151 0.136
15.0 198.3 844.7 1 945.2 2 789.9 2.314 5 4.126 1 6.440 6 0.001154 0.132
15.5 199.8 851.7 1 939.2 2 790.8 2.329 2 4.099 6 6.428 9 0.001156 0.128
16.0 201.4 858.6 1 933.2 2 791.7 2.343 6 4.073 9 6.417 5 0.001159 0.124
16.5 202.8 865.3 1 927.3 2 792.6 2.357 6 4.048 9 6.406 5 0.001161 0.120
17.0 204.3 871.8 1 921.5 2 793.4 2.371 3 4.024 5 6.395 7 0.001163 0.117
17.5 205.7 878.3 1 915.9 2 794.1 2.384 6 4.000 7 6.385 3 0.001166 0.113
18.0 207.1 884.6 1 910.3 2 794.8 2.397 6 3.977 5 6.375 1 0.001168 0.110
18.5 208.4 890.7 1 904.7 2 795.5 2.410 3 3.954 8 6.365 1 0.001170 0.107
19.0 209.8 896.8 1 899.3 2 796.1 2.422 8 3.932 6 6.355 4 0.001172 0.105
19.5 211.1 902.8 1 893.9 2 796.7 2.434 9 3.911 0 6.345 9 0.001174 0.102
20.0 212.4 908.6 1 888.6 2 797.2 2.446 9 3.889 8 6.336 6 0.001177 0.0995
20.5 213.6 914.3 1 883.4 2 797.7 2.458 5 3.869 0 6.327 6 0.001179 0.0971
21.0 214.8 920.0 1 878.2 2 798.2 2.470 0 3.848 7 6.318 7 0.001181 0.0949
21.5 216.1 925.5 1 873.1 2 798.6 2.481 2 3.828 8 6.310 0 0.001183 0.0927
22.0 217.2 931.0 1 868.1 2 799.1 2.492 2 3.809 3 6.301 5 0.001185 0.0907
22.5 218.4 936.3 1 863.1 2 799.4 2.503 0 3.790 1 6.293 1 0.001187 0.0887
23.0 219.5 941.6 1 858.2 2 799.8 2.513 6 3.771 3 6.284 9 0.001189 0.0868
23.5 220.7 946.8 1 853.3 2 800.1 2.524 1 3.752 8 6.276 9 0.001191 0.0849
24.0 221.8 951.9 1 848.5 2 800.4 2.534 3 3.734 7 6.269 0 0.001193 0.0832
24.5 222.9 957.0 1 843.7 2 800.7 2.544 4 3.716 8 6.261 2 0.001195 0.0815
25.0 223.9 962.0 1 839.0 2 800.9 2.554 3 3.699 3 6.253 6 0.001197 0.0799
25.5 225.0 966.9 1 834.3 2 801.2 2.564 0 3.682 1 6.246 1 0.001199 0.0783
26.0 226.0 971.7 1 829.6 2 801.4 2.573 6 3.665 1 6.238 7 0.001201 0.0769
26.5 227.1 976.5 1 825.1 2 801.6 2.583 1 3.648 4 6.231 5 0.001203 0.0754
27.0 228.1 981.2 1 820.5 2 801.7 2.592 4 3.632 0 6.224 4 0.001205 0.0740
(x) POWER PLANT ENGINEERING
27.5 229.1 985.9 1 816.0 2 801.9 2.601 6 3.615 8 6.217 3 0.001207 0.0727
28.0 230.0 990.5 1 811.5 2 802.0 2.610 6 3.599 8 6.210 4 0.001209 0.0714
28.5 231.0 995.0 1 807.1 2 802.1 2.619 5 3.584 1 6.203 6 0.001211 0.0701
29.0 232.0 999.5 1 802.6 2 802.2 2.628 3 3.568 6 6.196 9 0.001213 0.0689
29.5 233.0 1 004.0 1 798.3 2 802.2 2.637 0 3.553 3 6.190 2 0.001214 0.0677
30.0 233.8 1 008.4 1 793.9 2 802.3 2.645 5 3.538 2 6.183 7 0.001216 0.0666
30.5 234.7 1 012.7 1 789.6 2 802.3 2.653 9 3.523 3 6.177 2 0.001218 0.0655
31.0 235.6 1 017.0 1 785.4 2 802.3 2.662 3 3.508 7 6.170 9 0.001220 0.0645
31.5 236.5 1 021.2 1 781.1 2 802.3 2.670 5 3.494 2 6.164 7 0.001222 0.0634
32.0 237.4 1 025.4 1 776.9 2 802.3 2.678 6 3.479 9 6.158 5 0.001224 0.0624
32.5 238.3 1 029.6 1 772.7 2 802.3 2.686 6 3.465 7 6.152 3 0.001225 0.0615
33.0 239.2 1 033.7 1 768.6 2 802.3 2.694 5 3.451 8 6.146 3 0.001227 0.0605
33.5 240.0 1 037.8 1 764.4 2 802.2 2.702 3 3.438 0 6.140 3 0.001229 0.0596
34.0 240.9 1 041.8 1 760.3 2 802.1 2.710 1 3.424 4 6.134 4 0.001231 0.0587
34.5 241.7 1 045.8 1 756.3 2 802.1 2.717 7 3.410 9 6.128 6 0.001233 0.0579
35.0 242.5 1 049.8 1 752.2 2 802.0 2.725 3 3.397 6 6.122 8 0.001234 0.0570
35.5 243.3 1 053.7 1 748.2 2 801.8 2.732 7 3.384 4 6.117 1 0.001236 0.0562
36.0 244.2 1 057.6 1 744.2 2 801.7 2.740 1 3.371 4 6.111 5 0.001238 0.0554
36.5 245.0 1 061.4 1 740.2 2 801.6 2.747 4 3.358 5 6.105 9 0.001239 0.0546
37.0 245.7 1 065.2 1 736.2 2 801.4 2.754 7 3.345 8 6.100 4 0.001242 0.0539
37.5 246.5 1 069.0 1 732.3 2 801.3 2.761 8 3.333 2 6.095 0 0.001243 0.0531
38.0 247.3 1 072.7 1 728.4 2 801.1 2.768 9 3.320 7 6.089 6 0.001245 0.0524
38.5 248.1 1 076.4 1 724.5 2 800.9 2.775 9 3.308 3 6.084 2 0.001247 0.0517
39.0 248.8 1 080.1 1 720.6 2 800.8 2.782 9 3.296 1 6.078 9 0.001249 0.0511
39.5 249.6 1 083.8 1 716.8 2 800.5 2.789 7 3.284 0 6.073 7 0.001250 0.0504
40.0 250.3 1 087.4 1 712.9 2 800.3 2.796 5 3.272 0 6.068 5 0.001252 0.0497
41.0 251.8 1 094.6 1 705.3 2 799.9 2.809 9 3.248 3 6.058 2 0.001255 0.0485
42.0 253.2 1 101.6 1 697.8 2 799.4 2.823 1 3.225 1 6.048 2 0.001259 0.0473
43.0 254.6 1 108.5 1 690.3 2 798.8 2.836 0 3.202 3 6.038 3 0.001262 0.0461
44.0 256.0 1 115.4 1 682.9 2 798.3 2.848 7 3.179 9 6.028 6 0.001266 0.0451
45.0 257.4 1 122.1 1 675.6 2 797.7 2.861 2 3.157 9 6.019 1 0.001269 0.0440
46.0 258.7 1 128.8 1 668.3 2 797.0 2.873 5 3.136 2 6.009 7 0.001272 0.0430
47.0 260.1 1 135.3 1 661.1 2 796.4 2.885 5 3.114 9 6.000 4 0.001276 0.0421
48.0 261.4 1 141.8 1 653.9 2 795.7 2.897 4 3.093 9 5.991 3 0.001279 0.0412
49.0 262.6 1 148.2 1 646.8 2 794.9 2.909 1 3.073 3 5.982 3 0.001282 0.0403
50.0 263.9 1 154.5 1 639.7 2 794.2 2.920 6 3.052 9 5.973 5 0.001286 0.0394
51.0 265.1 1 160.7 1 632.7 2 793.4 2.931 9 3.032 8 5.964 8 0.001289 0.0386
52.0 266.4 1 166.8 1 625.7 2 792.6 2.943 1 3.013 0 5.956 1 0.001292 0.0378
53.0 267.6 1 172.9 1 618.8 2 791.7 2.954 1 2.993 5 5.947 6 0.001296 0.0371
54.0 268.7 1 178.9 1 611.9 2 790.8 2.965 0 2.974 2 5.939 2 0.001299 0.0363
STEAM TABLES AND MOLLIER DIAGRAM (xi)
55.0 269.9 1 184.9 1 605.0 2 789.9 2.975 7 2.955 2 5.930 9 0.001302 0.0356
56.0 271.1 1 190.8 1 598.2 2 789.0 2.986 3 2.936 4 5.922 7 0.001306 0.0349
57.0 272.2 1 196.6 1 591.4 2 788.0 2.996 7 2.917 9 5.914 6 0.001309 0.0343
58.0 273.3 1 202.3 1 584.7 2 787.0 3.007 1 2.899 5 5.906 6 0.001312 0.0336
59.0 274.4 1 208.0 1 578.0 2 786.0 3.017 2 2.881 4 5.898 6 0.001315 0.0330
60.0 275.5 1 213.7 1 571.3 2 785.0 3.027 3 2.863 5 5.890 8 0.001318 0.0324
61.0 276.6 1 219.3 1 564.7 2 784.0 3.037 2 2.845 8 5.883 0 0.001322 0.0319
62.0 277.7 1 224.8 1 558.0 2 782.9 3.047 1 2.828 3 5.875 3 0.001325 0.0313
63.0 278.7 1 230.3 1 551.5 2 781.8 3.056 8 2.810 9 5.867 7 0.001328 0.0308
64.0 279.8 1 235.7 1 544.9 2 780.6 3.066 4 2.793 8 5.860 1 0.001332 0.0302
65.0 280.8 1 241.1 1 538.4 2 779.5 3.075 9 2.776 8 5.852 7 0.001335 0.0297
66.0 281.8 1 246.5 1 531.9 2 778.3 3.085 3 2.760 0 5.845 2 0.001338 0.0292
67.0 282.8 1 251.8 1 525.4 2 777.1 3.094 6 2.743 3 5.837 9 0.001341 0.0287
68.0 283.8 1 257.0 1 518.9 2 775.9 3.103 8 2.726 8 5.830 6 0.001345 0.0283
69.0 284.8 1 262.2 1 512.5 2 774.7 3.112 9 2.710 5 5.823 3 0.001348 0.0278
70.0 285.8 1 267.4 1 506.0 2 773.5 3.121 9 2.694 3 5.816 2 0.001351 0.0274
71.0 286.7 1 272.5 1 499.6 2 772.2 3.130 8 2.678 2 5.809 0 0.001355 0.0269
72.0 287.7 1 277.6 1 493.3 2 770.9 3.139 7 2.662 3 5.802 0 0.001358 0.0265
73.0 288.6 1 282.7 1 486.9 2 769.6 3.148 4 2.646 5 5.794 9 0.001361 0.0261
74.0 289.6 1 287.7 1 480.5 2 768.3 3.157 1 2.630 9 5.788 0 0.001364 0.0257
75.0 290.5 1 292.7 1 474.2 2 766.9 3.165 7 2.615 3 5.781 0 0.001368 0.0253
76.0 291.4 1 297.6 1 467.9 2 765.5 3.174 2 2.599 9 5.774 2 0.001371 0.0249
77.0 292.3 1 302.5 1 461.6 2 764.2 3.182 7 2.584 6 5.767 3 0.001374 0.0246
78.0 293.2 1 307.4 1 455.3 2 762.8 3.191 1 2.569 5 5.760 5 0.001378 0.0242
79.0 294.1 1 312.3 1 449.1 2 761.3 3.199 4 2.554 4 5.753 8 0.001381 0.0239
80.0 294.9 1 317.1 1 442.8 2 759.9 3.207 6 2.539 5 5.747 1 0.001384 0.0235
81.0 295.8 1 321.9 1 436.6 2 758.4 3.215 8 2.524 6 5.740 4 0.001387 0.0232
82.0 296.7 1 326.6 1 430.3 2 757.0 3.223 9 2.509 9 5.733 8 0.001391 0.0229
83.0 297.5 1 331.4 1 424.1 2 755.5 3.232 0 2.495 2 5.727 2 0.001394 0.0225
84.0 298.4 1 336.1 1 417.9 2 754.0 3.239 9 2.480 7 5.720 6 0.001397 0.0222
85.0 299.2 1 340.7 1 411.7 2 752.5 3.247 9 2.466 3 5.714 1 0.001401 0.0219
86.0 300.1 1 345.4 1 405.5 2 750.9 3.255 7 2.451 9 5.707 6 0.001404 0.0216
87.0 300.9 1 350.0 1 399.3 2 749.4 3.263 6 2.437 6 5.701 2 0.001408 0.0213
88.0 301.7 1 354.6 1 393.2 2 747.8 3.271 3 2.423 5 5.694 8 0.001411 0.0211
89.0 302.5 1 359.2 1 387.0 2 746.2 3.279 0 2.409 4 5.688 4 0.001414 0.0208
90.0 303.3 1 363.7 1 380.9 2 744.6 3.286 7 2.395 3 5.682 0 0.001418 0.0205
91.0 304.1 1 368.3 1 374.7 2 743.0 3.294 3 2.381 4 5.675 7 0.001421 0.0202
92.0 304.9 1 372.8 1 368.6 2 741.4 3.301 8 2.367 6 5.669 4 0.001425 0.0199
93.0 305.7 1 377.2 1 362.5 2 739.7 3.309 3 2.353 8 5.663 1 0.001428 0.0197
94.0 306.4 1 381.7 1 356.3 2 738.0 3.316 8 2.340 1 5.656 8 0.001432 0.0194
(xii) POWER PLANT ENGINEERING
95.0 307.2 1 386.1 1 350.2 2 736.4 3.324 2 2.326 4 5.650 6 0.001435 0.0192
96.0 308.0 1 390.6 1 344.1 2 734.7 3.331 5 2.312 9 5.644 4 0.001438 0.0189
97.0 308.7 1 395.0 1 338.0 2 733.0 3.338 8 2.299 4 5.638 2 0.001442 0.0187
98.0 309.4 1 399.3 1 331.9 2 731.2 3.346 1 2.285 9 5.632 1 0.001445 0.0185
99.0 310.2 1 403.7 1 325.8 2 729.5 3.353 4 2.272 6 5.625 9 0.001449 0.0183
100.0 311.1 1 408.0 1 319.7 2 727.7 3.360 5 2.259 3 5.619 8 0.001452 0.0181
102.0 312.4 1 416.7 1 307.5 2 724.2 3.374 8 2.232 8 5.607 6 0.001459 0.0176
104.0 313.8 1 425.2 1 295.3 2 720.5 3.388 9 2.206 6 5.595 5 0.001467 0.0172
106.0 315.3 1 433.7 1 283.1 2 716.8 3.402 9 2.180 6 5.583 5 0.001474 0.0168
108.0 316.6 1 442.2 1 270.9 2 713.1 3.416 7 2.154 8 5.571 5 0.001481 0.0164
110.0 318.0 1 450.6 1 258.7 2 709.3 3.430 4 2.129 1 5.559 5 0.001488 0.0160
112.0 319.4 1 458.9 1 246.5 2 705.4 3.444 0 2.103 6 5.547 6 0.001496 0.0157
114.0 320.7 1 467.2 1 234.3 2 701.5 3.457 4 2.078 3 5.535 7 0.001504 0.0153
116.0 322.1 1 475.4 1 222.0 2 697.4 3.470 8 2.053 1 5.523 9 0.001511 0.0149
118.0 323.4 1 483.6 1 209.7 2 693.3 3.484 0 2.028 0 5.512 1 0.001519 0.0146
120.0 324.6 1 491.8 1 197.4 2 689.2 3.497 2 2.003 0 5.500 2 0.001527 0.0143
122.0 325.9 1 499.9 1 185.0 2 684.9 3.510 2 1.978 2 5.488 4 0.001535 0.0139
124.0 327.1 1 508.0 1 172.6 2 680.6 3.523 2 1.953 3 5.476 5 0.001543 0.0137
126.0 328.4 1 516.0 1 160.1 2 676.1 3.536 0 1.928 6 5.464 6 0.001551 0.0134
128.0 329.6 1 524.0 1 147.6 2 671.6 3.548 8 1.903 9 5.452 7 0.001559 0.0131
130.0 330.8 1 532.0 1 135.0 2 667.0 3.561 6 1.879 2 5.440 8 0.001567 0.0128
132.0 332.0 1 540.0 1 122.3 2 662.3 3.574 2 1.854 6 5.428 8 0.001576 0.0125
134.0 333.2 1 547.9 1 109.5 2 657.4 3.586 8 1.830 0 5.416 8 0.001584 0.0123
136.0 334.3 1 555.8 1 096.7 2 652.5 3.599 3 1.805 3 5.404 7 0.001593 0.0120
138.0 335.5 1 563.7 1 083.8 2 647.5 3.611 8 1.780 7 5.392 5 0.001602 0.0117
140.0 336.6 1 571.6 1 070.7 2 642.4 3.624 2 1.756 0 5.380 3 0.001611 0.0115
142.0 337.7 1 579.5 1 057.6 2 637.1 3.636 6 1.731 3 5.367 9 0.001619 0.0112
144.0 338.8 1 587.4 1 044.4 2 631.8 3.649 0 1.706 6 5.355 5 0.001629 0.0110
146.0 339.9 1 595.3 1 031.0 2 626.3 3.661 3 1.681 8 5.343 1 0.001638 0.0108
148.0 341.1 1 603.1 1 017.6 2 620.7 3.673 6 1.656 9 5.330 5 0.001648 0.0106
150.0 342.1 1 611.0 1 004.0 2 615.0 3.685 9 1.632 0 5.317 9 0.001658 0.0103
152.0 343.2 1 618.9 990.3 2 609.2 3.698 1 1.607 0 5.305 1 0.001668 0.0101
154.0 344.2 1 626.8 976.5 2 603.3 3.710 3 1.581 9 5.292 2 0.001678 0.00991
156.0 345.3 1 634.7 962.6 2 597.3 3.722 6 1.556 7 5.279 3 0.001689 0.00971
158.0 346.3 1 642.6 948.5 2 591.1 3.734 8 1.531 4 5.266 3 0.001699 0.00951
160.0 347.3 1 650.5 934.3 2 584.9 3.747 1 1.506 0 5.253 1 0.001710 0.00931
162.0 348.3 1 658.5 920.0 2 578.5 3.759 4 1.480 6 5.239 9 0.001721 0.00911
164.0 349.3 1 666.5 905.6 2 572.1 3.771 7 1.455 0 5.226 7 0.001733 0.00893
166.0 350.3 1 674.5 891.0 2 565.5 3.784 2 1.429 0 5.213 2 0.001745 0.00874
168.0 351.3 1 683.0 875.6 2 558.6 3.797 4 1.402 1 5.199 4 0.001757 0.00855
STEAM TABLES AND MOLLIER DIAGRAM (xiii)
170.0 352.3 1 691.7 859.9 2 551.6 3.810 7 1.374 8 5.185 5 0.001769 0.00837
172.0 353.2 1 700.4 844.0 2 544.4 3.824 0 1.347 3 5.171 3 0.001783 0.00819
174.0 354.2 1 709.0 828.1 2 537.1 3.837 2 1.319 8 5.157 0 0.001796 0.00801
176.0 355.1 1 717.6 811.9 2 529.5 3.850 4 1.292 2 5.142 5 0.001810 0.00784
178.0 356.0 1 726.2 795.6 2 521.8 3.863 5 1.264 3 5.127 8 0.001825 0.00767
180.0 356.9 1 734.8 779.1 2 513.9 3.876 5 1.236 2 5.112 8 0.001840 0.00750
182.0 357.8 1 743.4 762.3 2 505.8 3.889 6 1.207 9 5.097 5 0.001856 0.00733
184.0 358.7 1 752.1 745.3 2 497.4 3.902 8 1.179 2 5.082 0 0.001872 0.00717
186.0 359.6 1 760.9 727.9 2 488.8 3.916 0 1.150 1 5.066 1 0.001889 0.00701
188.0 360.5 1 769.7 710.1 2 479.8 3.929 4 1.120 5 5.049 8 0.001907 0.00684
190.0 361.4 1 778.7 692.0 2 470.6 3.942 9 1.090 3 5.033 2 0.001926 0.00668
192.0 362.3 1 787.8 673.3 2 461.1 3.956 6 1.059 4 5.016 0 0.001946 0.00652
194.0 363.2 1 797.0 654.1 2 451.1 3.970 6 1.027 8 4.998 3 0.001967 0.00636
196.0 364.0 1 806.6 634.2 2 440.7 3.984 9 0.995 1 4.980 0 0.001989 0.00620
198.0 364.8 1 816.3 613.5 2 429.8 3.999 6 0.961 4 4.961 1 0.002012 0.00604
200.0 365.7 1 826.5 591.9 2 418.4 4.014 9 0.926 3 4.941 2 0.002037 0.00588
202.0 366.5 1 837.0 569.2 2 406.2 4.030 8 0.889 7 4.920 4 0.002064 0.00571
204.0 367.3 1 848.1 545.1 2 393.3 4.047 4 0.851 0 4.898 4 0.002093 0.00555
206.0 368.2 1 859.9 519.5 2 379.4 4.065 1 0.809 9 4.875 0 0.002125 0.00538
208.0 368.9 1 872.5 491.7 2 364.2 4.084 1 0.765 7 4.849 8 0.002161 0.00521
210.0 369.8 1 886.3 461.3 2 347.6 4.104 8 0.717 5 4.822 3 0.002201 0.00502
212.0 370.6 1 901.5 427.4 2 328.9 4.127 9 0.663 9 4.791 7 0.002249 0.00483
214.0 371.3 1 919.0 388.4 2 307.4 4.154 3 0.602 6 4.756 9 0.002306 0.00462
216.0 372.1 1 939.9 341.6 2 281.6 4.186 1 0.529 3 4.715 4 0.002379 0.00439
218.0 372.9 1 967.2 280.8 2 248.0 4.227 6 0.434 6 4.662 2 0.002483 0.00412
220.0 373.7 2 011.1 184.5 2 195.6 4.294 7 0.285 2 4.579 9 0.002671 0.00373
221.2 374.1 2 107.4 0.0 2 107.4 4.442 9 0.0 4.442 9 0.003170 0.00317
(xiv) POWER PLANT ENGINEERING
TABLE III
Superheated Steam at Various Pressures and Temperatures
p (bar)
t (°C) 50 100 150 200 250 300 400 500
(ts )
v 149.1 172.2 195.3 218.4 241.5 264.5 310.7 356.8
0.01 u 2445.4 2516.4 2588.4 2661.6 2736.9 2812.2 2969.0 3132.4
(7.0) h 2594.5 2688.6 2783.6 2880.0 2978.4 3076.8 3279.7 3489.2
s 9.242 9.513 9.752 9.967 10.163 10.344 10.671 10.960
p (bar) t (°C) 200 250 300 350 400 450 500 600
(ts )
v 0.425 0.474 0.523 0.570 0.617 0.664 0.711 0.804
5.0 u 2642.9 2723.5 2802.9 2882.6 2963.2 3045.3 3128.4 3299.6
(151.8) h 2855.4 2960.7 3064.2 3167.7 3271.9 3377.2 3483.9 3701.7
s 7.059 7.271 7.460 7.633 7.794 7.945 8.087 8.353
p (bar) t (°C) 200 250 300 350 400 450 500 600
(ts )
p (bar)
t (°C) 350 375 400 450 500 550 600 700
(ts )
p (bar) t (°C) 350 375 400 450 500 550 600 700
(ts )
TABLE IV
Supercritical Steam
p(bar) t (°C)
350 375 400 425 450 500 600 700 800
230 v 0.00162 0.00221 0.00748 0.00915 0.01040 0.01239 0.01554 0.01821 0.02063
h 1632.8 1912.2 2691.2 2869.2 2995.8 3193.4 3510.0 3790.2 4056.2
s 3.137 4.137 5.327 5.587 5.765 6.030 6.415 6.719 6.980
250 v 0.00160 0.00197 0.00600 0.00788 0.00916 0.01112 0.01414 0.01665 0.01891
h 1623.5 1848.0 2580.2 2806.3 2949.7 3162.4 3491.4 3775.5 4047.1
s 3.680 4.032 5.142 5.472 5.674 5.959 6.360 6.671 6.934
300 v 0.00155 0.00179 0.00279 0.00530 0.00673 0.00868 0.01145 0.01366 0.01562
h 1608.5 1791.5 2151.1 2614.2 2821.4 3081.1 3443.9 3745.6 4024.2
s 3.643 3.930 4.473 5.150 5.442 5.790 6.233 6.561 6.833
350 v 0.00152 0.00110 0.00210 0.00343 0.00496 0.00693 0.00953 0.01153 0.01328
h 1597.1 1762.4 1987.6 2373.4 2672.4 2994.4 3395.5 3713.5 4001.5
s 3.612 3.872 4.213 4.775 5.196 5.628 6.118 6.463 6.745
400 v 0.00149 0.00164 0.00191 0.00253 0.00369 0.00562 0.00809 0.00994 0.01152
h 1588.3 1742.8 1930.9 2198.1 2512.8 2903.3 3346.4 3681.2 3978.7
s 3.586 3.829 4.113 4.503 4.946 5.470 6.011 6.375 6.666
500 v 0.00144 0.00156 0.00173 0.00201 0.00249 0.00389 0.00611 0.00773 0.00908
h 1575.3 1716.6 1874.6 2060.0 2284.0 2720.1 3247.6 3616.8 3933.6
s 3.542 3.764 4.003 4.273 4.588 5.173 5.818 6.219 6.529
600 v 0.00140 0.00150 0.00163 0.00182 0.00209 0.00296 0.00483 0.00627 0.00746
h 1566.4 1699.5 1843.4 2001.7 2179.0 2567.9 3151.2 3553.5 3889.1
s 3.505 3.764 3.932 4.163 4.412 4.932 5.645 6.082 6.411
700 v 0.00137 0.00146 0.00157 0.00171 0.00189 0.00247 0.00398 0.00526 0.00632
h 1560.4 1687.7 1822.8 1967.2 2122.7 2463.2 3061.7 3492.4 3845.7
s 3.473 3.673 3.877 4.088 4.307 4.762 5.492 5.961 6.307
800 v 0.00135 0.00142 0.00152 0.00163 0.00177 0.00219 0.00339 0.00452 0.00548
h 1556.4 1679.4 1808.3 1943.9 2086.9 2394.0 2982.7 3434.6 3803.8
s 3.444 3.638 3.833 4.031 4.232 4.642 5.360 5.851 6.213
900 v 0.00133 0.00139 0.00147 0.00157 0.00169 0.00201 0.00297 0.00397 0.00484
h 1553.9 1673.4 1797.7 1927.2 2062.0 2346.7 2915.6 3381.1 3763.8
s 3.419 3.607 3.795 3.984 4.174 4.554 5.247 5.753 6.128
1000 v 0.01308 0.00137 0.00144 0.00152 0.00163 0.00189 0.00267 0.00355 0.00434
h 1552.7 1669.4 1790.0 1914.8 2043.8 2312.8 2859.8 3332.3 3726.1
s 3.396 3.579 3.762 3.944 4.126 4.485 5.151 5.664 6.050
STEAM TABLES AND MOLLIER DIAGRAM (xix)
TABLE V
Conversion Factors
Force
1 newton = 1 kg-m/sec2
= 0.012 kgf
1 kgf = 9.81 N
Pressure
1 bar = 750.06 mm Hg
= 0.9869 atm
= 105 N/m2
= 103 kg/m-sec2
1 N/m2 = 1 pascal
= 10– 5 bar
= 10– 2 kg/m-sec2
1 atm = 760 mm Hg
= 1.03 kgf/cm2 = 1.01325 bar
= 1.01325 × 105 N/m2
Power
Thermal conductivity
8314
3. Gas constant (R) 29.27 kgf m/kg K for air = 287 joules/kg-K for air
29
7. Heat transfer
The Stefan Boltzmann Q = T4 kcal/m2-h Q = T4 watts/m2-h
Law is given by : when = 4.9 × 10 – 8 when = 5.67 × 10 – 8 W/m2K4
kcal/h-m2 K4