VALVES GENERAL CATALOG

SOLENOID VALVES
SERIES
INDEX

Features 631

SOLENOID VALVES 240 SERIES


Basic Models and Configuration 633
Specifications 635
Solenoid Valve, Air-piloted Valve Order Codes 637
Manifold Order Codes 638
Manifold for Serial Transmission System Order Codes 639
Operating Principles and Major Parts 640
Dimensions of Solenoid Valve 641
Dimensions of Manifold 646
Dimensions of Serial Transmission System 649
Made to Order 651
Handling Instructions and Precautions 656

Caution Before use, be sure to read the “Safety Precautions” on p. 31.


630
Multiple Application Systems for

SERIES
SOLENOID VALVES
Koganei, which has always supplied
products compatible with customer
needs, has recently developed the 240
series valves in response to worksite
requirements. The 240 series valves
are suitable for operating mid-sized
cylinders of bore sizes 63mm [2.480in.]
to 100mm [3.937in.], and offer every
required function. In addition to 5-port
2-position types, closed center and
exhaust center 3-position valves are
included in the product range.
Serial transmission modules, which
are compatible with connecting
directly to various manufacturers’
PCs, are also included in the product
variations.
The series realizes optimum system
design, offering space saving as well
as reducing wiring and piping work.

One-touch connect /disconnect Easy to increase or decrease the number


Plug-In Connector for Wiring of manifold units
Connections Stacking Type Manifold
●A plug-in connector is available for wiring connections between ●You can increase or decrease the number of manifold units
the solenoid valve and sub-base, as well as between the solenoid easily due to the individual manifold construction using each
valve and manifold, so that you can remove the solenoid valve solenoid valve mounted unit.
without disturbing the wiring portion. ●You can stock manifold bases as single units, thereby offering
you a reduction in stocking costs.

631
Easy Operation at Worksite.

SOLENOID VALVES 240 SERIES

You can select port direction and supply pressure Compatible with control by sequencers and PCs
according to your requirements. Low Power Consumption and Highly
The Bottom Ports on the Manifold Reliable Solenoid
Increase Versatility. ●By using a low power consumption solenoid, 1.6W at DC24V
and 65mA, improved reliability and low heat generation are
●You can use the bottom ports on the manifold for piping.
achieved.
●By using the port isolator between manifold station ports, you
●A serial transmission system, which offers distributed system
can supply multiple pressures on 1 manifold assembly.
control from a PC, is available and offers a cost reduction when
considering the complete pneumatic control system.
632
240 Series Basic Models and Configuration

Single unit
5-port
2-position 3- position

Single solenoid Double solenoid Closed center Exhaust center


Direct piping

240-4E1 240-4E2 243-4E2 243-4E2-13

2-position 3-position

Single solenoid Double solenoid Closed center Exhaust center


Standard sub-base piping

A240-4E1-25 A240-4E2-25 A243-4E2-25 A243-4E2-13-25


A240-4E1-27 A240-4E2-27 A243-4E2-27 A243-4E2-13-27

2-position 3-position

Single solenoid Double solenoid Closed center Exhaust center


Plug-in sub-base piping

These are dedicated valves for the manifold.

W240-4E1-26 W240-4E2-26 W243-4E2 W243-4E2-13


W240-4E1-28 W240-4E2-28

633
Manifold
Manifold for mounting 5-port valves

240M□F—F type 1(P), 3(R2), 5(R1)manifold

240M□A—A type (all ports) manifold

SOLENOID VALVES 240 SERIES


240M□B—B type (bottom ported all ports) manifold

240M□AW—AW type (plug-in and all ports) manifold

240M□BW—BW type (plug-in and bottom ported all ports) manifold

240M□AS□—AW type (side piping and compatible with serial transmission module) manifold

240M□BS□—BW type (bottom piping and compatible with serial transmission module) manifold

634
SOLENOID VALVES
SERIES

Specifications Solenoid Specifications


Basic Solenoid specifications Single solenoid Double solenoid 3-position Rated voltage
double solenoid AC100V AC200V DC24V
model For direct piping Item
For F type manifold 240-4E1 240-4E2 243-4E2
Flywheel diode incorporated
For standard type sub-base Type Shading type
A240-4E1 A240-4E2 A243-4E2 for surge suppression
For A type, B type manifolds
For pug-in type sub-base 90∼132 180∼264 21.6∼26.4
Item W240-4E1 W240-4E2 W243-4E2 Operating voltage range V
For AW, BW type manifolds (100 +32 +32
−10 %) (200 −10 %) (24±10%)
Media Air Frequency Hz 50 60 50 60 ─
Current
Operation type Internal pilot type (when rated mA (r.m.s.)
Starting 34 32 17 16 ─
Number of positions, Number of ports 2 positions, 5 ports 3 positions, 5 ports voltage is applied) Energizing 22 20 11 10 65 (1.6W)〔 75(1.8W)
mA (r.m.s.) with LED indicator 〕
Closed center
Valve function ── (standard) or Exhaust Allowable leakage current mA 4 2 4
center (optional) Insulation resistance MΩ Over 100
Effective area〔Cv〕 mm2 16〔0.88〕(11.3〔0.62〕) Note 1 15〔0.83〕(11〔0.61〕) Note 1
Standard Grommet type: 300mm [11.8in.]
P, A, B: Rc1/4 R: Rc1/8
Port size (P, A, B, R: Rc1/4 PR: Rc1/8) Note 2 Plug connector type
Lubrication Not required Straight connector
-PS: 300mm [11.8in.]※
Operating pressure range MPa {kgf/cm2} [psi.] 0.17∼0.7 {1.7∼7.1} [25∼102] -PSN: Without lead wire
(connector, contacts included)
Proof pressure MPa {kgf/cm2} [psi.] 1.05 {10.7} [152] Standard
L connector -PL: 300mm [11.8in.]※
Response time DC24V 25/35 20/20 25/55 type Optional
ms -PLN: Without lead wire
ON/OFF AC100V, AC200V 25/25 20/20 25/45 Wiring type (connector, contacts included)
Operating temperature range (atmosphere and media) °C [°F] 5∼50 [41∼122] ※1000 [39in.], 3000mm [118in.] also available as options.
Lateral direction 1373.0 {140.0} Specify separately when ordering
Shock resistance m/s2 {G} -1L: 1000, -3L: 3000.
Axial direction 451.1 {46.0} 264.8 {27.0} 588.4 {60.0}
Mounting direction Any Terminal type
Maximum operating frequency Hz 5 Plug-in type (Sub-base comes with conduit cover, and
Minimum time to energize ms ── 50 ── manifold with terminal cover)
160 [5.64] 230 [8.11] 260 [9.17] Color of lead wire Yellow White Red (+), Black (−)
Mass g [oz.] (350 [12.35]Note 3, (420 [14.81]Note 3, (450 [15.87]Note 3,
400 [14.11]Note 4) 470 [16.58]Note 4) 500 [17.64]Note 4) Color of LED indicator (optional) Yellow Green Red
Notes: 1. Effective area for A240-4E□, W240-4E□. 2. Port size of sub-base. Surge suppression Built-in varistor Flywheel diode
3. Mass of A240-4E□ with sub-base. 4. Mass of W240-4E□ with sub-base. (optional) (as standard)
Remarks: For optional specifications and order codes, see p.637∼639.

Manifold Specifications and Port Size


Manifold model Specifications Port size Applicable valve model Remarks
1(P), 3(R2), 5(R1) manifold 1(P) 240-4E1
240M□F piping 4(A), 2(B) Rc1/4 240-4E2 Piping not allowed on the PR port.
4(A), 2(B) valve piping 3(R2), 5(R1) 243-4E2
1(P)
A240-4E1
All port 4(A), 2(B) Rc1/4
240M□A A240-4E2
manifold piping 3(R2), 5(R1)
A243-4E2
PR Rc1/8
1(P)
All port W240-4E1
4(A), 2(B) Rc1/4
240M□AW manifold piping W240-4E2
3(R2), 5(R1)
plug-in type W243-4E2
PR Rc1/8
1(P)
End plate
4(A), 2(B) Rc1/4
and side By using port isolators, the 1(P), 4(A), 2(B), 3(R2) and 5(R1)
All port 3(R2), 5(R1) A240-4E1
port ports can be selected on either the end plate, side piping or
240M□B manifold piping PR Rc1/8 A240-4E2
bottom piping (the PR port is available only on the end
bottom ported 1(P) A243-4E2
Bottom plate).
4(A), 2(B) Rc1/8
port
3(R2), 5(R1)
1(P)
End plate
4(A), 2(B) Rc1/4
All port and side By using port isolators, the 1(P), 4(A), 2(B), 3(R2) and 5(R1)
3(R2), 5(R1) W240-4E1
manifold piping port ports can be selected on either the end plate, side piping or
240M□BW PR Rc1/8 W240-4E2
bottom ported bottom piping (the PR port is available only on the end
1(P) W243-4E2
plug-in type Bottom plate).
4(A), 2(B) Rc1/8
port
3(R2), 5(R1)
For order codes, see p.637∼639.
Manifold Mass g [oz.]
Manifold Mass calculation of each unit Mounting valve Block-off
model (n=number of units) 240-4E1 240-4E2 243-4E2 A240-4E1 A240-4E2 A243-4E2 W240-4E1 W240-4E2 W243-4E2 plate
240M□F (69×n)+69 [(2.43×n)+2.43] 160 [5.64] 230 [8.11] 260 [9.17] ── ── ── ── ── ──
240M□A (167×n)+217 [(5.89×n)+7.65] 160 [5.64] 230 [8.11] 260 [9.17] ── ── ──
240M□AW (199×n)+270 [(7.02×n)+9.52] ── ── ── 160 [5.64] 230 [8.11] 260 [9.17] 30 [1.06]
── ── ──
240M□B (167×n)+217 [(5.89×n)+7.65] 160 [5.64] 230 [8.11] 260 [9.17] ── ── ──
240M□BW (199×n)+270 [(7.02×n)+9.52] ── ── ── 160 [5.64] 230 [8.11] 260 [9.17]
Calculation example: The mass of 240M10F stn. 1∼5-240-4E1
stn. 6∼10-240-4E2, (69×10)+69+(160×5)+(230×5)=2709g [95.56oz.].
635
240-4E1 A240-4E1-25
Flow rate Flow rate
MPa
MPa 0.7 0.7

0.6 0.6
Valve outlet pressure

Valve outlet pressure


Supply pressure
0.5 0.7 Supply pressure 0.5 (MPa)
(MPa) 0.7
0.4 0.6 0.4
0.6
0.5
0.3 0.3 0.5
0.4 0.4
0.3
0.2 0.2 0.3
0.2 0.2
0.1 0.1 1MPa=145psi. 0.1 0.1
1R/min.=0.0353ft.3/min.
0 0
500 1000 1500 2000 500 1000 1500 2000
Flow rate R/min(ANR) Flow rate R/min(ANR)

Maximum operating speed Maximum operating speed

SOLENOID VALVES 240 SERIES


mm/s 1200 mm/s 1200
Maximum operating speed

Maximum operating speed


1000 1000

800 800
φ40 [1.575in.] φ40 [1.575in.]
600 φ50 [1.969in.] φ50 [1.969in.]
600
φ63 [2.480in.]
400 φ63 [2.480in.]
400
φ80 [3.150in.] φ80 [3.150in.]
200 φ100 [3.937in.] 200 φ100 [3.937in.]

0 1mm/s=0.0394in./sec.
0
10 20 30 40 50 60 70 10 20 30 40 50 60 70
Load ratio % Load ratio %

Delay time Delay time


φ100 [3.937in.]
s 1.0 φ100 [3.937in.] s 1.0
0.9 0.9
0.8 0.8
φ80 [3.150in.]
0.7 0.7
Delay time

Delay time

φ80 [3.150in.]
0.6 0.6 φ63 [2.480in.]
0.5 φ63 [2.480in.] 0.5
φ50 [1.969in.] φ50 [1.969in.]
0.4 0.4
φ40 [1.575in.] φ40 [1.575in.]
0.3 0.3
0.2 0.2
0.1 0.1
0 0
10 20 30 40 50 60 70 10 20 30 40 50 60 70
Load ratio % Load ratio %

Load Solenoid valve Load


A240-4E1-25
Measurement conditions Measurement conditions 0.5MPa
Solenoid valve
●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.]
●Piping inner diameter and length: φ7.5× 240-4E1
●Piping inner diameter and length: φ7.5×
Cylinder

Cylinder

1000mm [39in.] 1000mm [39in.]


●Fitting: Quick fitting TS10-02 ●Fitting: Quick fitting TS10-02
Load Load
●Load ratio= (%) ●Load ratio= (%)
Cylinder theoretical thrust 0.5MPa Cylinder theoretical thrust
●Cylinder stroke: 300mm [11.8in.] ●Cylinder stroke: 300mm [11.8in.]
Fitting TS10-02

Fitting TS10-02

How to obtain cylinder speed


To obtain the time required for the cylinder to
Cylinder stroke

complete 1 stroke, add cylinder’s delay time t1


(time between energizing of the solenoid valve
and actual starting of the cylinder), to the
cylinder’s max. speed operating time t 2.
When a cushion is used, add the cushioning time
t1 t2 t3 time t3, to the above calculations. The standard
Solenoid Cylinder Cushioning Cylinder cushioning time t 3 is approximately 0.2 seconds.
valve start impact stop
energized

636
240 Series Solenoid Valve, Air-piloted Valve Order Codes
3-position valve Mounting base Sub-base Speed controller Manual override Wiring type Wiring type
Valve function (standard type) (plug-in type)

Without Side piping Without speed


Closed center mounting base standard type controller Non-locking type Grommet type Standard plug-in

4(A) 5(R1)
2(B) 1(P) Varistor
3(R2)
Blank Blank -25 Blank Blank Blank -ZR Blank
Standard Standard With built-in varistor
With mounting Side piping With speed for surge suppression With LED
Exhaust center base plug-in type controller Locking type Straight connector with LED indicator indicator

4(A) 5(R1)
2(B) 1(P) Diode
3(R2)

-13 -21 -26 -70 -81 -PS-L -PSN-L -L


With lead wire Without lead wire
Side and bottom piping Connector, contacts included With built-in varistor for
standard type L connector with LED indicator surge suppression

Varistor

-27 -PL-L -PLN-L -ZR


With lead wire Without lead wire
Side and bottom piping Connector, contacts
plug-in type DIN connector included

-28 -39

Basic model Voltage

Single solenoid 240-4E1 -21 -81 -ZR,-39


DC24V
-PS-L
2-position
Direct piping double solenoid 240-4E2 -70 -PSN-L AC100V
-PL-L
3-position
243-4E2 -13 -81 -PLN-L AC200V
double solenoid

Single solenoid A240-4E1 -81 -ZR,-39


DC24V
Standard -25 -PS-L
2-position
sub-base piping double solenoid A240-4E2 -70 Note 1 -PSN-L AC100V
-27 -PL-L
3-position
A243-4E2 -13 -81 -PLN-L AC200V
double solenoid

Single solenoid W240-4E1 -26 -81 DC24V


Plug-in -70 Note 1 -L
2-position
W240-4E2 -28 AC100V
sub-base piping double solenoid
-ZR
3-position
W243-4E2 Note 2 -13 -81 AC200V
double solenoid
Direct piping Single pilot 240-4A -21
air-piloted valves -70
(made to order) Double pilot 240-4A2
Sub-base piping Single pilot A240-4A -25
air-piloted valves -70 Note 1
(made to order) Double pilot A240-4A2 -27
Notes: 1. Attached to the sub-base.
●Not available for 240-4E2,A240-4E2,W240-4E2.
2. Because the long valve
●-ZR: Varistor for surge suppression is available for AC100V and AC200V
body interferes with the
only (flywheel diode for surge suppression is standard equipment
connector, no sub-base is
for DC24V) and a varistor for surge suppression is built into
set in the order codes.
AC100V and AC200V with LED indicator.
●When ordering the non-ion specifi-
●Color of LED indicator AC100V: yellow, AC200V: green, DC24V: red
cation, enter -NCU after the basic
model code. ●-PS-L,-PL-L: Lead wire length can be selected.
When ordering, specify -1L: 1000, -3L: 3000. Lead wire length: mm [in.]
300 [11.8]—Standard 1000 [39], 3000 [118]—Optional
Options
Mounting base Plug-in type sub-base Speed controller Manual override Straight connector L connector DIN connector

-21 -26 -28 -70 -81 -PS-L -PL-L -39


●Side piping ●Side and bottom ●Attached to the sub- ●Locking type ●With lead wire and ●With lead wire and
type piping type base in the case of LED indicator LED indicator
sub-base type. Surge suppression Surge suppression

637
240 Series Manifold Order Codes
3-position valve Manual override Wiring type Wiring type
Valve function (standard type) (plug-in type)

Closed center Non-locking type Grommet type Standard plug-in

4(A) 5(R1)
2(B) 1(P) Varistor
3(R2)
Blank Blank Blank -ZR Blank
Standard Standard With built-in varistor
for surge suppression With LED
Exhaust center Locking type Straight connector with LED indicator indicator

4(A) 5(R1)
2(B) 1(P) Diode
3(R2)

-13 -81 -PS-L -PSN-L -L


With lead wire Without lead wire
Connector, contacts included With built-in varistor
L connector with LED indicator for surge suppression

Varistor

SOLENOID VALVES 240 SERIES


-PL-L -PLN-L -ZR
With lead wire Without lead wire
Connector, contacts
DIN connector included

-39

Manifold model
Number of units Station Basic model Voltage

stn.□ -240-4E1 -81 -ZR,-39


DC24V
-PS-L
F ⋮ -240-4E2 -PSN-L AC100V
-PL-L
stn.□ -243-4E2 -13 -81 -PLN-L AC200V

Manifold 2 stn.□ -A240-4E1 -81 -ZR,-39


DC24V
A -PS-L
for mounting 5-port 240M ⋮ ⋮ -A240-4E2 -PSN-L AC100V
valves B -PL-L
10 stn.□ -A243-4E2 -13 -81 -PLN-L AC200V

stn.□ -W240-4E1 -81 DC24V


AW -L
⋮ -W240-4E2 AC100V
BW -ZR
stn.□ -W243-4E2 -13 -81 AC200V
stn.□ -240-4A
Manifold 2 F ⋮
for mounting 5-port stn.□ -240-4A2
valves 240M ⋮
(made to order) 10 A stn.□ -A240-4A

B stn.□ -A240-4A2
●Valve mounting location from ●Specify the valve model for each station.
the left-hand side when facing ●Enter -BP when closing a station with a block-off plate without
the 4(A), 2(B) ports. mounting a valve.
●When ordering the non-ion specification, enter -NCU after the
basic model code.

Made to order
Air-piloted valves
240 series

●5-port, 2-position
●Single pilot
●Double pilot

638
Symbols

Single solenoid 2-position double solenoid 3-position double solenoid


Closed center Exhaust center

14(S2) 14(S2) 14(S2)

4(A) 5(R1) 4(A) 5(R1) 4(A) 5(R1) 4(A) 5(R1)


2(B) 1(P) 2(B) 1(P) 2(B) 1(P) 2(B) 1(P)
3(R2) 3(R2) 3(R2) 3(R2)

12(S1)

12(S1) 12(S1)

Operating Principles and Major Parts Major Parts and Materials


Parts Materials
Solenoid cover
●240-4E1 Aluminum alloy
Body
Column (treated with chromic acid)
De-energized Energized Stem Aluminum alloy (anodized)
Shading coil

SOLENOID VALVES 240 SERIES


(AC solenoid only) Lip seal
Synthetic rubber
Molded solenoid Flapper

Plunger
Mounting base Mild steel (zinc plated)
Plunger spring
Sub-base Aluminum alloy (anodized)

Manual override
Plunger Magnetic stainless
Column steel
Plunger pin
PR
Piston
Remark: Materials that generate copper
ions are not used for the non-
Pilot valve body
ion specification.
Flapper 5(R1) 5(R1)
Stem
4(A) 4(A)

1(P) 1(P)
Body

2(B) 2(B)
3(R2) 3(R2)

Lip seal

End cover

●240-4E2 ●243-4E2 ●243-4E2-13


(De-energized condition after energizing solenoid 12(S1)) (Both solenoid 12(S1)and 14(S2)are de-energized.) (Both solenoid 12(S1)and 14(S2)are de-energized.)

14(S2) 14(S2) 14(S2)

(R1)
5
4(A)

1(P)
4(A) 4(A)
2(B) 1(P) 1(P)
3(R2)
2(B) 2(B)

12(S1)

12(S1) 12(S1)

640
Dimensions of Solenoid Valve (mm)

●240-4E1 240-4E1

Approximately
23 300 35
Manual override PR1
Non-locking type: Standard
Locking type: -81 2-Rc1/8

2-φ3.3 2-φ3.3
4(A)Port 5(R1)Port
Counterbore R3 Depth 3 Mounting
1(P)Port
Mounting hole hole
R1
A
103.2

19.6
22

36
40

35.5
25.7
24.5

17.5
15.5

R2

2(B)Port 2 2 3-Rc1/4 8 3(R2)Port PR2


9 9 3 3

2-M3×0.5 Depth 4
Mounting thread
11.5 11.5

7 7

●240-4E2 240-4E2

Approximately
23 300 35
2-Manual overrides 2-PR
Non-locking type
(S2)
14
2-φ3.3 2-Rc1/8
Mounting
2-φ3.3 hole 5(R1)Port
4(A)Port Counterbore R3 Depth 3 1(P)Port
Mounting hole
A 2(B)Port R1
19.6

36
22
40
135.4

B R2
67.7
57.9
56.7

49.7
47.7

3(R2)Port

(S1)
12

3-Rc1/4
2 2 8 3 3

9 9

641
●243-4E2 243-4E2

Approximately
23 300 35
2-Manual override
Non-locking type: Standard
Locking type: -81 2-PR
(S2)
14

2-φ3.3 2-Rc1/8
Mounting hole
2-φ3.3 5(R1)Port
4(A)Port Counterbore R3 Depth 3
1(P)Port
Mounting hole
R1
A 2(B)Port
165.4

19.6

36
40

22

B R2

SOLENOID VALVES 240 SERIES


82.7
3(R2)Port
71.7

72.9

64.7
62.7

(S1)
12

3-Rc1/4
2 2 8 3 3
9 9

Options

●Mounting base: -21 ●Straight connector with LED indicator: -PS(N)-L ●With built-in varistor for surge
240SC 240SOL suppression: -ZR
Dimensions are the same as
(To the top surface of the valve)

23
the standard product.
0.5 41
0.5 22 10
108.8

2 11
5.6

B
1.6

R
(Overall length of the valve)

2-φ4.5
31
240-4E1:110.5

Mounting
240-4E2:150
243-4E2:180

hole
35

6
LED indicator

18 18
46

●Speed controller: -70 ●L connector with LED indicator: -PL(N)-L ●DIN connector: -39
240SC 240SOL 240SOL

23 R 52 DIN connector
(-39) 2.4 63
(21) 0.5 22 21 10 31
Manual override 13
2 11 17 M12×1.25
(Overall length of the valve)

(25.1)
11.4

(32.5)

φ14.8
S2
23.7

23.5

10 14.8
Width across flats
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4

R1/8
LED indicator

642
Dimensions of Solenoid Valve (mm)

A240-4E1
●A240-4E1-25
●A240-4E1-27

43 82.5
9 23 11 38.5 43
Approximately
300 35
21 Manual override
10 Non-locking type: Standard 27.5
Locking type: -81
21
Rc1/8
PR
PR

5(R1)
103.2
4(A)

A
68.5

58.5

1(P)
21

40
55

2(B)

30
19.5

3(R2)
4.5

10
5.5

5-Rc1/4
34 4.5
2-φ4.5
Mounting hole 〈Viewed from A〉
-27: Bottom port
M5×0.8
PR
5-Rc1/4

5(R1)Port
4(A)Port
R

PR
A
1(P)Port
P

23
40
55
R

30
18.5
B
(B)Port
2
3(R2)Port
10

10.5
25
34.5

●A240-4E2-25 A240-4E2

●A240-4E2-27
43 82.5
9 23 11 38.5 43
Approximately
300 35
21 2-Manual overrides
Non-locking type 27.5
10
21
(S2)
14
Rc1/8
PR
PR

5(R1)
4(A)

A
58.5
68.5

1(P)
21

40
135.4
55

2(B)

30
3(R2)
19.5

10
4.5

5-Rc1/4
37.7

(S1)
12

2-φ4.5 34 4.5
Mounting hole

643
A243-4E2
●A243-4E2-25
●A243-4E2-27
43 82.5
9 23 11 Approximately 38.5 43
300 35
2-Manual overrides
Non-locking type: Standard 27.5
21 Locking type: -81
21
10 (S2)
14

Rc1/8
PR
PR

5(R1)
4(A)

A
68.5

58.5

1(P)
21

40
165.4
55

2(B)

30
3(R2)
19.5

4.5

SOLENOID VALVES 240 SERIES


10
5-Rc1/4
52.7

12(S1)

〈Viewed from A〉
2-φ4.5 34 4.5 -27: Bottom port
Mounting hole
M5×0.8
PR
5-Rc1/4

5(R1)Port
(A)Port
4
R

PR
A
1(P)Port
P
23
40
55

R
30
18.5

B
(B)Port
2
3(R2)Port
10

10.5
25
34.5

Options
●Speed controller:-70 ●Straight connector with LED indicator: -PS(N)-L ●L connector with LED indicator: -PL(N)-L
240SC 240SOL 240SOL
85
(21) (To the bottom of the sub-base)
23 0.5 41 96
(To the bottom of the sub-base)
16.2

0.5 22 10
23 R 52
2 11 2.5
0.5 22 21
14
Width across flats 2 11 13.5
R

R1/4
(Overall length of the valve)

●Dimensions for the built-in varistor


23.5
23.7
A240-4E1: 110.5

31

for surge suppression are the


A240-4E2: 150
A243-4E2: 180

same as for the standard product.

LED indicator

●DIN connector: -39


240SOL LED indicator
DIN connector
(-39) 2.4 63
10 31
Manual override 13
M12×1.25
(Overall length of the valve)

(25.1)
(32.5)

φ14.8
S2
14.8
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4

644
Dimensions of Solenoid Valve (mm)

43
20.6 82.5
●W240-4E1-26 φ10
W240-4E1
28 8.5 (9) 60
●W240-4E1-28 9 23 11

Manual override
Non-locking type: Standard
Locking type: -81

52.5
Rc1/8
PR

133.5
139

A
PR

5(R1)
103.2

〈Viewed from A〉
4(A)

58.5

1(P)
68.5

-28: Bottom port


21

40
55

2(B)

30
3(R2)
19.5

M5×0.8

10
4.5
5-Rc1/4 PR
5.5

21
10 5-Rc1/8
34 4.5
27.5
21 2-φ4.5
Mounting hole 38.5 43 5(R1)Port
R (A)Port
4

PR
A
1(P)Port
43 P

●W240-4E2-26

40
23
20.6 82.5

55
φ10 R
28 8.5 (9) 60
●W240-4E2-28

30
18.5
B
9 23 11 2(B)Port
W240-4E2
3(R2)Port

10
2-Manual overrides 10.5
Non-locking type
25
34.5
52.5

14(S2)
Rc1/8
PR
133.5
171.2
PR

5(R 1)
4(A)

A
68.5
135.4

58.5

1(P)

40
21
55

2(B)

30
3(R 2)
19.5

10
4.5
37.7

5-Rc1/4
12(S1)
10
21
21
2-φ4.5 27.5
Mounting hole 34 4.5 38.5 43

Options

●Speed controller: -70 ●With LED indicator: -L ● Plug-in type with built-in varistor for surge
240SC suppression: -ZR
85
(21) (To the bottom of the sub-base) Dimensions are the same as the standard
0.5 41 product.
23 10
16.2

0.5 22 2.5

14
Width across flats
23.7

R1/4

LED indicator
645
Dimensions of Manifold (mm)

240MF
●240M□F

Approximately
L 300 64
5 P 5 35 28
24 24 24 24 19
12.5 23 23 12.5 4-φ4.5 11
Manual override Mounting hole
Non-locking type: Standard 10
Locking type: -81 6-Rc1/4
(S2)
14
(with 3 plugs)
(S2)
14
67.7

5(R1)
A A A A
98.7

1(P)
165.4
20

SOLENOID VALVES 240 SERIES


22

16
40
52
62
35.5

31
3(R2)
21
24.5

23
B B B B

11
4(A)Port
4.5
36.7

2 2
(B)Port
2
51.7

(S1)
12

Rc1/4 (S1)
12

240-4E1 240-4E2 243-4E2 Block-off plate


(-BP)

Unit dimensions
Model L P
240M2F 72 62
240M3F 96 86
stn.1  stn.2  stn.3  stn.4  stn.5   240M4F 120 110
240M5F 144 134
240M6F 168 158
240M7F 192 182
240M8F 216 206
240M9F 240 230
240M10F 264 254

Options

●Straight connector with LED indicator: -PS(N)-L ●L connector with LED indicator: -PL(N)-L ● Built-in varistor for surge suppression: -ZR
240SOL 70 240SOL Dimensions are the same as the standard
(To the bottom of the product.
manifold)
23 0.5 41 81 ●DIN connector:-39
10
(To the bottom of the manifold) 240SOL
0.5 22
23 R 52
2 11
0.5 22 21 DIN connector
(-39) 2.4 63
2 11 17
10 31
R

Manual override 13
(Overall length of the valve)

M12×1.25
(Overall length of the valve)

(25.1)
31

23.7

23.5

(32.5)
240-4E1:110.5

φ14.8
240-4E2:150
243-4E2:180

S2
14.8
6
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4

LED indicator
LED indicator

646
Dimensions of Manifold (mm)

240MA
●240M□A
●240M□B
L
5 P 5 87
44.5 28 28 44.5 Approximately 38.5 47.5
33 23 23 33 4-R2.5 300 35 37
Manual override Mounting hole
32
Non-locking type: Standard 6-Rc1/4
Locking type: -81 12.5 12.5 17

44.2
29.2

3
5
15

5(R1)
103.2

1(P)
165.4

31
53
64

79
79

3(R2)

41.5
PR

26.5
15.5
7.5
5
27.2

3
42.2
2-Rc1/8
PR

A240-4E1 A240-4E2 A243-4E2 Block-off plate 〈Viewed from A〉240M□B: Bottom port
(-BP) 4(A)Port 5(R1)Port

2-Rc1/4

R1

R1

R1

R1
R1
per each station
1(P)Port

A
A
22
47

P
P

3(R2)Port B

B
B
41

R2

R2

R2

R2
R2
30

B B B B B
16

2(B)Port
37.5

6.5 14 5-Rc1/8 14 7.5


A A A A A per each station
30.5 28 28 30.5
stn.1  stn.2  stn.3  stn.4  stn.5  4(A)Port
11.5
5

1 2(B)Port Unit dimensions


4
Model L P
240M2A, 240M2B 117 107
240M3A, 240M3B 145 135
240M4A, 240M4B 173 163
240M5A, 240M5B 201 191
240M6A, 240M6B 229 219
240M7A, 240M7B 257 247
240M8A, 240M8B 285 275
240M9A, 240M9B 313 303
240M10A, 240M10B 341 331

Options

●Straight connector with LED indicator: -PS(N)-L ●L connector with LED indicator: -PL(N)-L ●With built-in varistor for
240SOL 89.5 240SOL surge suppression: -ZR
(To the bottom of the manifold) Dimensions are the same
23 0.5 41 as the standard product.
100.5
0.5 22 10 (To the bottom of the manifold)
11 23 R 52
2 2.5 ●DIN connector: -39 240SOL
0.5 22 21
DIN connector
2 11 13.5 (-39) 2.4 63
R

10 31
Manual override 13
(Overall length of the valve)

M12×1.25
(Overall length of the valve)
31

(25.1)
23.7

23.5

(32.5)

φ14.8
S2
A240-4E1:110.5
A240-4E2:150
A243-4E2:180

14.8
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4

LED indicator

LED indicator

647
Dimensions of Manifold (mm)

240MAW
●240M□AW
87
●240M□BW
38.5 47.5
L
37
5 P 5
32
44.5 28 28 44.5
21.5
2-G1/2
33 23 23 33 17
Manual override 12.5 12.5 4-R2.5
Non-locking type: Standard 6
Mounting hole 6-Rc1/4
Locking type: -81

14(S2)

44.2
14(S2)
29.2

5
15

125.5

5(R1)
103.2

110.5
A
152.7

1(P)

31
53
64
79

167.7
79

SOLENOID VALVES 240 SERIES


3(R 2)

41.5
PR

26.5
15.5
5
27.2

7.5

3
12(S1)
42.2
2-Rc1/8
12(S1)

W240-4E1 W240-4E2 W243-4E2 Block-off plate


(-BP )

2-Rc1/4
per each station

B B B B B
37.5

A A A A A
〈Viewed from A〉240M□BW: Bottom port
stn.1  stn.2  stn.3  stn.4  stn.5
11.5

4(A)Port
5

1 2(B)Port
4
5(R1)Port
Unit dimensions
4(A)Port
Model L P
R1

R1

R1

R1

R1

240M 2 AW, 240M 2 BW 117 107


(P)Port
1
A

240M 3 AW, 240M 3 BW 145 135


240M 4 AW, 240M 4 BW 173 163
22
47

(B)Port
2
P

240M 5 AW, 240M 5 BW 201 191


B

B
R2

R2

R2

R2
R2
41

240M 6 AW, 240M 6 BW 229 219


30
16

240M 7 AW, 240M 7 BW 257 247


240M 8 AW, 240M 8 BW 285 275
240M 9 AW, 240M 9 BW 313 303 6.5 14 14 7.5
(R2)Port
3 5-Rc1/8
240M10AW, 240M10BW 341 331 30.5 28 per each station 28 30.5
Options
89.5
(To the bottom of the manifold)
●With LED indicator: -L 0.5 41 ●Plug-in type with built-in varistor for surge
23 suppression: -ZR
10
0.5 22 2.5 Dimensions are the same as the standard
product.
23.7

LED indicator

648
Made to Order
Air-piloted valves 240 series
●The optimum air valve for master valves or pilot valves for all-pneumatic control.

Specifications
For direct piping For sub-base
F type manifold For A type and B type manifolds
Single pilot Double pilot Single pilot Double pilot
Item Basic model 240-4A 240-4A2 A240-4A A240-4A2
Media Air
Operation type Air piloted type
Number of positions, Number of ports 2 positions, 5 ports
Effective area〔Cv〕 mm2 16〔0.88〕 11.3〔0.627〕
Main 1(P), 4(A) , 2(B)
:Rc1/4 3(R2)
, 5(R1) :Rc1/8 1(P) , 4(A) , 2(B)
, 3(R2), 5(R1):Rc1/4 Piston R: Rc1/8 Note 1
Port size
Pilot Rc1/8
Lubrication Not required
Operating pressure range Main 0.17∼0.7 {1.7∼7.1} [25∼102]
MPa {kgf/cm2} [psi.] Pilot See the table “Minimum Pilot Pressure”
Proof pressure MPa {kgf/cm2} [psi.] 1.05 {10.7} [152]
Operating temperature range (atmosphere and media) °C[°F] 5∼60 [41∼140]
Shock Lateral direction 1373.0 {140.0}
m/s {G}
2
resistance Axial direction 912.0{93.0} 264.8{27.0} 912.0{93.0} 264.8{27.0}
Mounting direction Any
Maximum operating frequency Hz 5
Mass g [oz.] 110 [3.88] 135 [4.76] 110 [3.88](300 [10.58])Note 2 135 [4.76](325 [11.46])Note 2
Notes: 1. Port size of sub-base and manifold.
2. Figures in parentheses ( ) are the mass with sub-base.
Remarks: For optional specifications and order codes, see p.637∼638.

Minimum Pilot Pressure MPa {kgf/cm2} [psi.] Measurement Conditions


Model Main pressure 0.15{1.5}[22]※ 0.3{3.1}[44] 0.5{5.1}[73] 0.7{7.1}[102]
L ●Pilot valve=050-4E1
240-4A 0.15{1.5}[22] 0.22{2.2}[32] 0.31{3.2}[45] 0.4
{4.1}[58]
Pilot valve (effective area 1.2mm2
240-4A2 0.06{0.6}[9] 0.07 {0.7}[10] 0.09{0.9}[13] 0.1
{1.0}[15]
(B port plugged) 〔Cv: 0.07〕)
※: Reference value.
●Tube inner diameter
240-4A =4mm [0.16in.]
Time Required for Switching s ●Air pressure
Pilot line length L m [ft.] (both main and pilot)
Model Operation L
2 [6.6] 6 [19.7] 10 [32.8] 20 [65.6] 50 [164] 100 [328] =0.5MPa [73psi.]
ON 0.07 0.18 0.32 0.65 2.10 5.80
240-4A Pilot valve
OFF 0.15 0.42 0.72 1.50 4.32 12.20
ON 240-4A2
240-4A2 0.09 0.23 0.40 0.83 2.73 7.0
OFF

Manifold Specifications and Port Size


Manifold model Specifications Port size Applicable valve model Remarks
1(P), 3(R2), 5(R1) ports 1(P)
240-4A
240M□F manifold piping 4(A), 2(B) Rc1/4
240-4A2
4(A), 2(B) ports valve piping 3(R2), 5(R1)
1(P)
All port 4(A), 2(B) Rc1/4 A240-4A Piston R becomes pilot R when
240M□A
manifold piping 3(R2), 5(R1) A240-4A2 mounting the solenoid valve.
Piston R Rc1/8
1(P)
End plate By using port isolators, the 1(P),
4(A), 2(B) Rc1/4
and 4(A), 2(B), 3(R2) and 5(R1) ports
All port side port 3(R2), 5(R1)
A240-4A can be selected on either the end
240M□B manifold piping Piston R Rc1/8
A240-4A2 plate, side piping or bottom piping.
Bottom ported 1(P) Piston R becomes pilot R when
Bottom port 4(A), 2(B) Rc1/8 mounting the solenoid valve.
3(R2), 5(R1)
For order codes, see p.638.

Manifold Mass g [oz.]

Mass of calculation for each unit Mounting valve


Manifold model Block-off plate
(n=number of units)
240-4A 240-4A2
A240-4A2 A240-4A
240M□F (68×n)+69 (2.40×n)
[ +2.43] 110 [3.88] − 135 [4.76] − 30 [1.06]
240M□A (167×n)+217 (5.89×n)
[ +7.65] − 135 [4.76]
− 110 [3.88]
30 [1.06]
240M□B (167×n)+217 (5.89×n)
[ +7.65] − 135 [4.76]
− 110 [3.88]
Calculation example: The mass of 240M10F stn.1∼51 240-4A
The mass of 240M10F stn.6∼10 240-4A2, (68×10)+69+(110×5)+(135×5)=1974g [69.63oz.].
651
Cylinder Operating Speed and Flow Rate

240-4A A240-4A-25

Measurement conditions Measurement conditions


●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.]
●Piping inner diameter and length: φ7.5×1000mm [39in.] ●Piping inner diameter and length: φ7.5×1000mm [39in.]
●Fitting: Quick fitting TS10-02 ●Fitting: Quick fitting TS10-02
Load Load
●Load ratio= (%) ●Load ratio= (%)
Cylinder theoretical thrust Cylinder theoretical thrust
●Cylinder stroke: 300mm [11.8in.] ●Cylinder stroke: 300mm [11.8in.]

Load Load
Air-piloted valve A240-4A-25
0.5MPa

SOLENOID VALVES 240 SERIES


Air-piloted valve 240-4A
Cylinder

Cylinder
0.5MPa
Fitting TS10-02

Fitting TS10-02

Maximum operating speed Maximum operating speed


mm/s 1200 mm/s 1200
Maximum operating speed

Maximum operating speed

1000 1000

800 800
φ40 [1.575in.] φ40 [1.575in.]
600 φ50 [1.969in.] 600 φ50 [1.969in.]
φ63 [2.480in.] φ63 [2.480in.]
400 400
φ80 [3.150in.] φ80 [3.150in.]
200 φ100 [3.937in.] 200 φ100 [3.937in.]

0 0
10 20 30 40 50 60 70 10 20 30 40 50 60 70
Load ratio % Load ratio %
1mm/s=0.0394in./sec.

Flow rate Flow rate


MPa
MPa 0.7 0.7

0.6 0.6
Valve outlet pressure

Valve outlet pressure

0.5 0.5
0.7 Inlet Inlet
0.6
pressure 0.7 pressure
0.4 0.4 0.6
0.5 0.5
0.3 0.3
0.4 0.4
0.3 0.2 0.3
0.2
0.2 0.2
0.1 0.1
0.1 0.1

0 0
500 1000 1500 2000 500 1000 1500 2000
Flow rate R/min(ANR) Flow rate R/min(ANR)
1MPa=145psi.
1R/min.=0.0353ft3/min.

652
Operating Principles and Symbols

5-port, 2-position

Single pilot Double pilot

240-4A 240-4A2

14(PA) 14(PA)

4(A) 5(R1) 4(A) 5(R1)


2(B) (P)
1 2(B) 1(P)
3(R2) 3(R2)
12(PB)

240-4A 240-4A2
Pilot connection port

Normal condition Actuated condition (Condition with pilot air applied to 12(PB),
and then released)
Piston

14(PA)
Body

Piston R

5(R1)
(R1)
5 5(R1)
4(A)
4(A) 4(A)
1(P)
1(P) 1(P)
2(B)
(B)
2 2(B)
3(R2)
3(R2) 3(R2)

Lip seal

Stem

End cover
12(PB)

Major Parts and Materials


Parts Materials
Body Aluminum alloy
Stem (anodized)
Valve Lip seal Synthetic rubber
Mounting base Mild steel (zinc plated)
Sub-base Aluminum alloy (anodized)
Body Aluminum alloy (anodized)
Manifold Block-off plate Mild steel (zinc plated)
Seal Synthetic rubber

653
Dimensions of Air-piloted Valves (mm)

●240-4A

23 Rc1/8 35 2-Piston R
Pilot connection port
2-Rc1/8

2-φ3.3 Counterbore R3 Depth 3 2-φ3.3


Mounting hole Mounting
hole
5(R1)
4(A)
79.5

19.6
22
40

36
1(P)

35.5
25.7
24.5

2(B)

17.5
15.5

3(R2)

2 2 3-Rc1/4 8
9 9 3 3

SOLENOID VALVES 240 SERIES


2-M3×0.5 Depth 4
Mounting thread
11.5 11.5

7 7

●240-4A2

23 2-Rc1/8 35
2-Piston R
Pilot connection port

2-φ3.3 2-Rc1/8
Mounting
2-φ3.3 Counterbore R3 Depth 3 hole
Mounting hole
14(PA)
5(R1)
4(A)
19.6
22

36
40
88

1(P)

2(B)
44
34.2

3(R2)
33

26
24

12(PB)

3-Rc1/4
2 2 8 3 3
9 9

Options

●Mounting base: -21 ●Speed controller: -70


(To the top surface of the valve)

(21)
108.8

11.4
5.6

B
1.6

10
Width across flats
2-φ4.5 R1/8
Mounting hole
35

18 18
46
654
Dimensions of Air-piloted Valves (mm)

●A240-4A-25
●A240-4A-27
43 82.5

9 23 11 38.5 43
21 35
Rc1/8
10 Pilot connection port 17.5 27.5

21
Rc1/8
Piston R

5(R1)
PR
4(A)

79.5

1(P)
68.5
21

58.5
A
55

40
2(B)

3(R2)

30
19.5

10
4.5
5.5

5-Rc1/4
34 4.5
2-φ4.5
Mounting hole

●A240-4A2-25
●A240-4A2-27
43 82.5
9 23 11 38.5 43

21 35
2-Rc1/8
10 Pilot connection port 17.5 27.5

21
Rc1/8
Piston R

14(PA)
5(R1)
PR
4(A)

A
1(P)
58.5
68.5
88
21

40
55

2(B)

3(R2)

30
19.5

12(PB)
4.5
14

10

5-Rc1/4

2-φ4.5 34 4.5
Mounting hole

Options 〈Viewed from A〉


-27: Bottom port
●Speed controller: -70
M5×0.8
Piston R
(21)
5-Rc1/4
16.2

5(R1)
PR

4(A)
14
Width across flats 1(P)
23
40

R1/4
55

3(R2)
30
18.5

2(B)
10

10.5
25
34.5

655
Handling Instructions and Precautions

Solenoid Plug connector Manual override

Internal circuit Attaching and removing plug connector Non-locking type


Use fingers to insert the connector into the To operate the manual override, press it all
●AC100V, AC200V
pin, push it in until the lever claw latches the way down. For single solenoid, the valve
Solenoid (Surge onto the protruded section of the connector works the same as when in the energized
suppression) housing, and complete the connection. state as long as the manual override is
Standard solenoid
Order code: -ZR To remove the connector, squeeze the lever pushed down, and returns to the normal
along with the connector, lift the lever claw position upon release.
up from the protruded section of the For the double solenoid, pressing the manual
connector housing, and pull it out. override on the 12(S1) side switches the
Solenoid
Protruded section 12(S1) to enter the energized position, and the
Varistor
Pin unit remains in that state even after the
Lead wire AC100V: Yellow
Connector housing manual override is released. To return it to the
AC200V: White
Lever
normal position, operate the manual override
Connector
on the 14(S2) side. This is the same for the
Solenoid with LED indicator assembly solenoids 14(S2).
(Surge suppression)
Order code: -PS-L

SOLENOID VALVES 240 SERIES


-PL-L
Indication of polarity
LED indicator (DC)
(Light Emitting Diode)
Connector
Contact

Diode
※Illustration shows the 110 series.
PU
Color of LED indicator AC100V: Yellow SH
AC200V: Green
Crimping of connecting lead wire and contact
To crimp lead wires into contacts, strip off
●DC24V 4mm [0.16in.] of the insulation from the tip ※Illustration shows the 110 series.
of the lead wire, insert it into the contact,
Standard solenoid (Surge suppression) and crimp it. Be sure to avoid catching the Locking type
insulation on the exposed wire crimping
Short circuit protection diode section. To lock the manual override, use a small
(+) Exposed wire 4mm
Lead wire: Red Lead wire screwdriver to push down on the manual
Solenoid Contact Equivalent to override all the way down and turn it 45
AWG22∼26
Flywheel degrees. Either turning direction at this time
diode
(−) is acceptable.
Lead wire: Black When locked, turning the manual override
Insulation crimp tab from the locking position releases a spring
Insulation(Maximum on the manual override, returns it to its
Hook Exposed wire crimping section outer diameterφ1.7)
Solenoid with LED indicator normal position, and releases the lock.
(Surge suppression) Cautions: 1. Do not pull hard on the lead wire. When the manual override is not turned, this
Order code: -PS-L 2. Always use a dedicated tool for type acts just like the non-locking type.
-PL-L crimping of connecting lead wire
LED indicator and contact.
(Light Emitting Diode)
Contact: Model 702062-2M
(+) Manufactured by Sumiko Tech, Inc.
Lead wire: Red Crimping tool: Model F1-702062
Manufactured by Sumiko Tech, Inc.
(−) TURN
Lead wire: Black LED indicator: Red Attaching and removing contact and connector
Insert the contact with lead wire into a plug
connector □ hole until the contact hook
latches on the connector and is secured to
the plug connector. Confirm that the lead PU
SH
wire cannot be easily pulled out.
To remove it, insert a tool with a fine tip
(such as a small screwdriver) into the
rectangular hole on the side of the plug
※Illustration shows the 240 series.
connector to push up on the hook, and then
pull out the lead wire. Cautions: 1. The 240 series valves are pilot type
solenoid valves. As a result, the
manual override cannot switch the
main valve without air supplied from
the 1(P) port.
2. Always release the lock of the lock-
ing type manual overrides before
commencing normal operation.
3. Do not attempt to operate the
Cautions: 1. Do not pull hard on the lead wire. It manual override with a pin or other
could result in defective contacts, object having an extremely fine tip.
breaking wires, etc. It could damage the manual
2. If the pin is bent, use a small override button.
screwdriver, etc. to gently straighten 4. Do not turn the adjusting knob
out the pin, and then complete the more than needed. It could result in
connection to the plug connector. defective operation.

656
Handling Instructions and Precautions

Manifold

t y u e End plate A
240M□A(W)
r
240M□B(W)

End plate B Port isolator q w i o 10 Illustration shows 240M□AW.

Piping Stacking unit order


The 1(P) port, 3(R2) port, 5(R1) port and PR If stacking part is required due to the addition or replacement of manifold units, use the following order codes to
port are on both ends of the manifold, and place orders.
piping direction can be selected depending on No. Parts Order codes Parts lists (quantities)
the mounting location. At shipping, the ports
A type stacking unit (1): q joints (2), w joint mounting bolts (2), e
on one side are plugged. Remove the plugs Stacking unit for
— CR016 valve mounting screws (3), r gasket (1), t gasket (1),
and then use sealing tape or another sealing 240M□A
y O-rings (3)
agent to tighten in place.
B type stacking unit (1): q joints (2), w joint mounting bolts (2), e
Stacking unit for
— CR017 valve mounting screws (3), r gasket (1), t gasket (1),
240M□B
y O-rings (3), u O-ring (1), Rc1/8 plugs (5), Rc1/4 plugs (2)
Cautions: 1. For the 1(P) port piping, use a size
that matches the manifold’s piping AW type stacking unit (1): q joints (2), w joint mounting bolts (2), e
connection port. Insufficient flow rate Stacking unit for valve mounting screws (3), r gasket (1), t gasket (1),
— CR018
240M□AW y O-rings (3), i terminal block (1), o terminal cover (1),
or pressure could result in defective
!0 connection cover (1)
valve operation or in insufficient
actuator output. BW type stacking unit (1): q joints (2), w joint mounting bolts (2), e
2. When installing piping or mufflers to Stacking unit for valve mounting screws (3), r gasket (1), t gasket (1), y O-rings
— CR019
240M□BW (3), u O-ring (1), i terminal block (1), o terminal cover (1),
the 3(R2) and 5(R1) ports, ensure
!0 connection cover (1), Rc1/8 plugs (5), Rc1/4 plugs (2)
there will be minimum exhaust
resistance. On rare occasions, i Terminal block CR020
exhaust from valves can interference
with other valves and actuators.
3. When a multiple number of valves
operate simultaneously on a multi-
unit manifold, or when the manifold
with valves is used at high frequency,
supply air from the 1(P) ports on both
ends, and exhaust air from the 3(R2),
5(R1) ports on both ends.
4. In bottom ported manifolds (B type
and BW type), use of the bottom
1(P), 3(R2) and 5(R1) ports can
prevent flow rate or pressure
shortages, or exhaust interference.

657
Plug-in DIN connector

Stacking Mounting and removing valves Wiring instructions


The A Type, B Type, AW Type and BW Type With the plug-in type, valves can be ●Solenoid with DIN connector
manifolds are the stacking type, for flexible replaced while leaving the air piping or When de-sheathing (outer sheath of the
addition or reduction of units. electrical wiring in place. cabtyre only), pay attention to the outlet
Loosen the 3 valve mounting screws, and direction of the lead wire. The cover will be
●Assembly instructions pull the valve straight out. To mount the easy to mount when the lead wire on the outer
240M□A and 240M□B valve, align the valve plug over the socket of side of the terminal cover interior is set to
the sub-base or manifold, and fit it straight about 8mm [0.31in.] longer than the inner side.
Loosening the joint mounting bolts (hexagon
in. Then tighten the valve mounting screws Without stripping off the sheath, insert the lead
socket head bolts) w on both ends and
to secure it in place. wire until it contacts the lead wire stopper on
removing the joint q lets the stations be
separated. the terminal body, and then place the contact
To add units, position the O-rings y and u from the upper side. Then use pliers to press
and gasket t in the stacking unit stations, the lead wire further to ensure that the
install the joint, and tighten the joint contacts are firmly holding the core wire.
Socket
mounting bolts.
JIS C3306

SOLENOID VALVES 240 SERIES


240M□AW and 240M□BW VCTF Electric conductor 0.75mm2
1
Finished outside 6.6(2 leads)
Loosen the set screw on the terminal cover, 7.0(3 leads)
3 2
_
remove the terminal cover o and Cable +

connection cover !0, and pull out the Plug Cable gland
Solenoid terminal
terminal block i. Socket Cable gasket location
Washer
Loosening the joint mounting bolts on both
Contact
sides and removing the joint lets the stations Lead wire
Lead wire

be separated. To add units, first position O- Plug stopper

rings and gaskets in the stations to be No.1 terminal (−) Gasket

added, install the joint, and tighten the joint No. 2 terminal (−) Cover
mounting Terminal
Lead wire Terminal
Gasket body
mounting bolts. Then, fit the terminal block, screw cover Terminal body Pliers
secure the terminal cover in place with
mounting screws, and fit the connection Note: The appropriate tightening torque for the cover
No.1 terminal (+) mounting screw is 29.4N・cm {3kgf・cm}
cover. No. 2 terminal (+) [2.6in・lbf].
Bottom port
Since the B Type and BW Type manifolds Wiring instructions
have piping ports on the bottom of the In the plug-in type, the terminal block and
manifold, both the bottom and side ports can solenoid are connected by a plug and
be used as required. socket. Loosen the terminal cover mounting
screws, remove the terminal cover, and
●Piping port location then pull out the terminal block and connect
With the 1(P) port on both ends and the it. Fit the connected terminal block into the
bottom surface, the 4(A) and 2(B) ports on sub-base or manifold, mount the terminal
the side and bottom surfaces, and the 3(R2) cover, then secure the mounting screws in
and 5(R1) ports on both ends and the place.
bottom surface, piping is allowed in any Connect the single solenoid leads to the
location. Use the plugs provided with the No. 2 (+, −) terminal.
manifold, with sealing tape or another In the double solenoid, the No.1 (+, −)
sealing agent, to block off the unused ports. terminals are connected to the valve’s
solenoid 12 (S1), and the No.2 (+, −)
Port isolator terminals to the solenoid 14 (S2). For DC
models, pay attention to the polarity. While
Port isolators on the 1(P), 3(R2) and a wrong in polarity will not cause a short
5(R1) ports can be used to separate them circuit, the valve will not operate.
from adjacent stations, to allow supply of For the terminal, use the round terminal
different pressures, or to prevent exhaust JIS2805 R type 1.25-3 or equivalent.
interference. To order the terminal block and other parts
Port isolators can be fitted and assembled for adding units, see the manifold parts
between stations in place of the O-rings y order item on p.657. A collective common
to separate the 1(P), 3(R2) and 5(R1) ports type manifold that uses crossover contacts
from adjacent stations. For stations split by can also be manufactured. Consult us.
port isolators, plumb the 1(P), 3(R2) and
5(R1) ports on the bottom.

Block-off plate
To close up the unused stations, use a
block-off plate (order code: -BP).

658