SOLENOID VALVES
SERIES
INDEX
Features 631
SERIES
SOLENOID VALVES
Koganei, which has always supplied
products compatible with customer
needs, has recently developed the 240
series valves in response to worksite
requirements. The 240 series valves
are suitable for operating mid-sized
cylinders of bore sizes 63mm [2.480in.]
to 100mm [3.937in.], and offer every
required function. In addition to 5-port
2-position types, closed center and
exhaust center 3-position valves are
included in the product range.
Serial transmission modules, which
are compatible with connecting
directly to various manufacturers’
PCs, are also included in the product
variations.
The series realizes optimum system
design, offering space saving as well
as reducing wiring and piping work.
631
Easy Operation at Worksite.
You can select port direction and supply pressure Compatible with control by sequencers and PCs
according to your requirements. Low Power Consumption and Highly
The Bottom Ports on the Manifold Reliable Solenoid
Increase Versatility. ●By using a low power consumption solenoid, 1.6W at DC24V
and 65mA, improved reliability and low heat generation are
●You can use the bottom ports on the manifold for piping.
achieved.
●By using the port isolator between manifold station ports, you
●A serial transmission system, which offers distributed system
can supply multiple pressures on 1 manifold assembly.
control from a PC, is available and offers a cost reduction when
considering the complete pneumatic control system.
632
240 Series Basic Models and Configuration
Single unit
5-port
2-position 3- position
2-position 3-position
2-position 3-position
633
Manifold
Manifold for mounting 5-port valves
240M□AS□—AW type (side piping and compatible with serial transmission module) manifold
240M□BS□—BW type (bottom piping and compatible with serial transmission module) manifold
634
SOLENOID VALVES
SERIES
0.6 0.6
Valve outlet pressure
800 800
φ40 [1.575in.] φ40 [1.575in.]
600 φ50 [1.969in.] φ50 [1.969in.]
600
φ63 [2.480in.]
400 φ63 [2.480in.]
400
φ80 [3.150in.] φ80 [3.150in.]
200 φ100 [3.937in.] 200 φ100 [3.937in.]
0 1mm/s=0.0394in./sec.
0
10 20 30 40 50 60 70 10 20 30 40 50 60 70
Load ratio % Load ratio %
Delay time
φ80 [3.150in.]
0.6 0.6 φ63 [2.480in.]
0.5 φ63 [2.480in.] 0.5
φ50 [1.969in.] φ50 [1.969in.]
0.4 0.4
φ40 [1.575in.] φ40 [1.575in.]
0.3 0.3
0.2 0.2
0.1 0.1
0 0
10 20 30 40 50 60 70 10 20 30 40 50 60 70
Load ratio % Load ratio %
Cylinder
Fitting TS10-02
636
240 Series Solenoid Valve, Air-piloted Valve Order Codes
3-position valve Mounting base Sub-base Speed controller Manual override Wiring type Wiring type
Valve function (standard type) (plug-in type)
4(A) 5(R1)
2(B) 1(P) Varistor
3(R2)
Blank Blank -25 Blank Blank Blank -ZR Blank
Standard Standard With built-in varistor
With mounting Side piping With speed for surge suppression With LED
Exhaust center base plug-in type controller Locking type Straight connector with LED indicator indicator
4(A) 5(R1)
2(B) 1(P) Diode
3(R2)
Varistor
-28 -39
637
240 Series Manifold Order Codes
3-position valve Manual override Wiring type Wiring type
Valve function (standard type) (plug-in type)
4(A) 5(R1)
2(B) 1(P) Varistor
3(R2)
Blank Blank Blank -ZR Blank
Standard Standard With built-in varistor
for surge suppression With LED
Exhaust center Locking type Straight connector with LED indicator indicator
4(A) 5(R1)
2(B) 1(P) Diode
3(R2)
Varistor
-39
Manifold model
Number of units Station Basic model Voltage
Made to order
Air-piloted valves
240 series
●5-port, 2-position
●Single pilot
●Double pilot
638
Symbols
12(S1)
12(S1) 12(S1)
Plunger
Mounting base Mild steel (zinc plated)
Plunger spring
Sub-base Aluminum alloy (anodized)
Manual override
Plunger Magnetic stainless
Column steel
Plunger pin
PR
Piston
Remark: Materials that generate copper
ions are not used for the non-
Pilot valve body
ion specification.
Flapper 5(R1) 5(R1)
Stem
4(A) 4(A)
1(P) 1(P)
Body
2(B) 2(B)
3(R2) 3(R2)
Lip seal
End cover
(R1)
5
4(A)
1(P)
4(A) 4(A)
2(B) 1(P) 1(P)
3(R2)
2(B) 2(B)
12(S1)
12(S1) 12(S1)
640
Dimensions of Solenoid Valve (mm)
●240-4E1 240-4E1
Approximately
23 300 35
Manual override PR1
Non-locking type: Standard
Locking type: -81 2-Rc1/8
2-φ3.3 2-φ3.3
4(A)Port 5(R1)Port
Counterbore R3 Depth 3 Mounting
1(P)Port
Mounting hole hole
R1
A
103.2
19.6
22
36
40
35.5
25.7
24.5
17.5
15.5
R2
2-M3×0.5 Depth 4
Mounting thread
11.5 11.5
7 7
●240-4E2 240-4E2
Approximately
23 300 35
2-Manual overrides 2-PR
Non-locking type
(S2)
14
2-φ3.3 2-Rc1/8
Mounting
2-φ3.3 hole 5(R1)Port
4(A)Port Counterbore R3 Depth 3 1(P)Port
Mounting hole
A 2(B)Port R1
19.6
36
22
40
135.4
B R2
67.7
57.9
56.7
49.7
47.7
3(R2)Port
(S1)
12
3-Rc1/4
2 2 8 3 3
9 9
641
●243-4E2 243-4E2
Approximately
23 300 35
2-Manual override
Non-locking type: Standard
Locking type: -81 2-PR
(S2)
14
2-φ3.3 2-Rc1/8
Mounting hole
2-φ3.3 5(R1)Port
4(A)Port Counterbore R3 Depth 3
1(P)Port
Mounting hole
R1
A 2(B)Port
165.4
19.6
36
40
22
B R2
72.9
64.7
62.7
(S1)
12
3-Rc1/4
2 2 8 3 3
9 9
Options
●Mounting base: -21 ●Straight connector with LED indicator: -PS(N)-L ●With built-in varistor for surge
240SC 240SOL suppression: -ZR
Dimensions are the same as
(To the top surface of the valve)
23
the standard product.
0.5 41
0.5 22 10
108.8
2 11
5.6
B
1.6
R
(Overall length of the valve)
2-φ4.5
31
240-4E1:110.5
Mounting
240-4E2:150
243-4E2:180
hole
35
6
LED indicator
18 18
46
●Speed controller: -70 ●L connector with LED indicator: -PL(N)-L ●DIN connector: -39
240SC 240SOL 240SOL
23 R 52 DIN connector
(-39) 2.4 63
(21) 0.5 22 21 10 31
Manual override 13
2 11 17 M12×1.25
(Overall length of the valve)
(25.1)
11.4
(32.5)
φ14.8
S2
23.7
23.5
10 14.8
Width across flats
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4
R1/8
LED indicator
642
Dimensions of Solenoid Valve (mm)
A240-4E1
●A240-4E1-25
●A240-4E1-27
43 82.5
9 23 11 38.5 43
Approximately
300 35
21 Manual override
10 Non-locking type: Standard 27.5
Locking type: -81
21
Rc1/8
PR
PR
5(R1)
103.2
4(A)
A
68.5
58.5
1(P)
21
40
55
2(B)
30
19.5
3(R2)
4.5
10
5.5
5-Rc1/4
34 4.5
2-φ4.5
Mounting hole 〈Viewed from A〉
-27: Bottom port
M5×0.8
PR
5-Rc1/4
5(R1)Port
4(A)Port
R
PR
A
1(P)Port
P
23
40
55
R
30
18.5
B
(B)Port
2
3(R2)Port
10
10.5
25
34.5
●A240-4E2-25 A240-4E2
●A240-4E2-27
43 82.5
9 23 11 38.5 43
Approximately
300 35
21 2-Manual overrides
Non-locking type 27.5
10
21
(S2)
14
Rc1/8
PR
PR
5(R1)
4(A)
A
58.5
68.5
1(P)
21
40
135.4
55
2(B)
30
3(R2)
19.5
10
4.5
5-Rc1/4
37.7
(S1)
12
2-φ4.5 34 4.5
Mounting hole
643
A243-4E2
●A243-4E2-25
●A243-4E2-27
43 82.5
9 23 11 Approximately 38.5 43
300 35
2-Manual overrides
Non-locking type: Standard 27.5
21 Locking type: -81
21
10 (S2)
14
Rc1/8
PR
PR
5(R1)
4(A)
A
68.5
58.5
1(P)
21
40
165.4
55
2(B)
30
3(R2)
19.5
4.5
12(S1)
〈Viewed from A〉
2-φ4.5 34 4.5 -27: Bottom port
Mounting hole
M5×0.8
PR
5-Rc1/4
5(R1)Port
(A)Port
4
R
PR
A
1(P)Port
P
23
40
55
R
30
18.5
B
(B)Port
2
3(R2)Port
10
10.5
25
34.5
Options
●Speed controller:-70 ●Straight connector with LED indicator: -PS(N)-L ●L connector with LED indicator: -PL(N)-L
240SC 240SOL 240SOL
85
(21) (To the bottom of the sub-base)
23 0.5 41 96
(To the bottom of the sub-base)
16.2
0.5 22 10
23 R 52
2 11 2.5
0.5 22 21
14
Width across flats 2 11 13.5
R
R1/4
(Overall length of the valve)
31
LED indicator
(25.1)
(32.5)
φ14.8
S2
14.8
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4
644
Dimensions of Solenoid Valve (mm)
43
20.6 82.5
●W240-4E1-26 φ10
W240-4E1
28 8.5 (9) 60
●W240-4E1-28 9 23 11
Manual override
Non-locking type: Standard
Locking type: -81
52.5
Rc1/8
PR
133.5
139
A
PR
5(R1)
103.2
〈Viewed from A〉
4(A)
58.5
1(P)
68.5
40
55
2(B)
30
3(R2)
19.5
M5×0.8
10
4.5
5-Rc1/4 PR
5.5
21
10 5-Rc1/8
34 4.5
27.5
21 2-φ4.5
Mounting hole 38.5 43 5(R1)Port
R (A)Port
4
PR
A
1(P)Port
43 P
●W240-4E2-26
40
23
20.6 82.5
55
φ10 R
28 8.5 (9) 60
●W240-4E2-28
30
18.5
B
9 23 11 2(B)Port
W240-4E2
3(R2)Port
10
2-Manual overrides 10.5
Non-locking type
25
34.5
52.5
14(S2)
Rc1/8
PR
133.5
171.2
PR
5(R 1)
4(A)
A
68.5
135.4
58.5
1(P)
40
21
55
2(B)
30
3(R 2)
19.5
10
4.5
37.7
5-Rc1/4
12(S1)
10
21
21
2-φ4.5 27.5
Mounting hole 34 4.5 38.5 43
Options
●Speed controller: -70 ●With LED indicator: -L ● Plug-in type with built-in varistor for surge
240SC suppression: -ZR
85
(21) (To the bottom of the sub-base) Dimensions are the same as the standard
0.5 41 product.
23 10
16.2
0.5 22 2.5
14
Width across flats
23.7
R1/4
LED indicator
645
Dimensions of Manifold (mm)
240MF
●240M□F
Approximately
L 300 64
5 P 5 35 28
24 24 24 24 19
12.5 23 23 12.5 4-φ4.5 11
Manual override Mounting hole
Non-locking type: Standard 10
Locking type: -81 6-Rc1/4
(S2)
14
(with 3 plugs)
(S2)
14
67.7
5(R1)
A A A A
98.7
1(P)
165.4
20
16
40
52
62
35.5
31
3(R2)
21
24.5
23
B B B B
11
4(A)Port
4.5
36.7
2 2
(B)Port
2
51.7
(S1)
12
Rc1/4 (S1)
12
Unit dimensions
Model L P
240M2F 72 62
240M3F 96 86
stn.1 stn.2 stn.3 stn.4 stn.5 240M4F 120 110
240M5F 144 134
240M6F 168 158
240M7F 192 182
240M8F 216 206
240M9F 240 230
240M10F 264 254
Options
●Straight connector with LED indicator: -PS(N)-L ●L connector with LED indicator: -PL(N)-L ● Built-in varistor for surge suppression: -ZR
240SOL 70 240SOL Dimensions are the same as the standard
(To the bottom of the product.
manifold)
23 0.5 41 81 ●DIN connector:-39
10
(To the bottom of the manifold) 240SOL
0.5 22
23 R 52
2 11
0.5 22 21 DIN connector
(-39) 2.4 63
2 11 17
10 31
R
Manual override 13
(Overall length of the valve)
M12×1.25
(Overall length of the valve)
(25.1)
31
23.7
23.5
(32.5)
240-4E1:110.5
φ14.8
240-4E2:150
243-4E2:180
S2
14.8
6
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4
LED indicator
LED indicator
646
Dimensions of Manifold (mm)
240MA
●240M□A
●240M□B
L
5 P 5 87
44.5 28 28 44.5 Approximately 38.5 47.5
33 23 23 33 4-R2.5 300 35 37
Manual override Mounting hole
32
Non-locking type: Standard 6-Rc1/4
Locking type: -81 12.5 12.5 17
44.2
29.2
3
5
15
5(R1)
103.2
1(P)
165.4
31
53
64
79
79
3(R2)
41.5
PR
26.5
15.5
7.5
5
27.2
3
42.2
2-Rc1/8
PR
A240-4E1 A240-4E2 A243-4E2 Block-off plate 〈Viewed from A〉240M□B: Bottom port
(-BP) 4(A)Port 5(R1)Port
2-Rc1/4
R1
R1
R1
R1
R1
per each station
1(P)Port
A
A
22
47
P
P
3(R2)Port B
B
B
41
R2
R2
R2
R2
R2
30
B B B B B
16
2(B)Port
37.5
Options
●Straight connector with LED indicator: -PS(N)-L ●L connector with LED indicator: -PL(N)-L ●With built-in varistor for
240SOL 89.5 240SOL surge suppression: -ZR
(To the bottom of the manifold) Dimensions are the same
23 0.5 41 as the standard product.
100.5
0.5 22 10 (To the bottom of the manifold)
11 23 R 52
2 2.5 ●DIN connector: -39 240SOL
0.5 22 21
DIN connector
2 11 13.5 (-39) 2.4 63
R
10 31
Manual override 13
(Overall length of the valve)
M12×1.25
(Overall length of the valve)
31
(25.1)
23.7
23.5
(32.5)
φ14.8
S2
A240-4E1:110.5
A240-4E2:150
A243-4E2:180
14.8
240-4E1:117.2
240-4E2:163.4
243-4E2:193.4
LED indicator
LED indicator
647
Dimensions of Manifold (mm)
240MAW
●240M□AW
87
●240M□BW
38.5 47.5
L
37
5 P 5
32
44.5 28 28 44.5
21.5
2-G1/2
33 23 23 33 17
Manual override 12.5 12.5 4-R2.5
Non-locking type: Standard 6
Mounting hole 6-Rc1/4
Locking type: -81
14(S2)
44.2
14(S2)
29.2
5
15
125.5
5(R1)
103.2
110.5
A
152.7
1(P)
31
53
64
79
167.7
79
41.5
PR
26.5
15.5
5
27.2
7.5
3
12(S1)
42.2
2-Rc1/8
12(S1)
2-Rc1/4
per each station
B B B B B
37.5
A A A A A
〈Viewed from A〉240M□BW: Bottom port
stn.1 stn.2 stn.3 stn.4 stn.5
11.5
4(A)Port
5
1 2(B)Port
4
5(R1)Port
Unit dimensions
4(A)Port
Model L P
R1
R1
R1
R1
R1
(B)Port
2
P
B
R2
R2
R2
R2
R2
41
LED indicator
648
Made to Order
Air-piloted valves 240 series
●The optimum air valve for master valves or pilot valves for all-pneumatic control.
Specifications
For direct piping For sub-base
F type manifold For A type and B type manifolds
Single pilot Double pilot Single pilot Double pilot
Item Basic model 240-4A 240-4A2 A240-4A A240-4A2
Media Air
Operation type Air piloted type
Number of positions, Number of ports 2 positions, 5 ports
Effective area〔Cv〕 mm2 16〔0.88〕 11.3〔0.627〕
Main 1(P), 4(A) , 2(B)
:Rc1/4 3(R2)
, 5(R1) :Rc1/8 1(P) , 4(A) , 2(B)
, 3(R2), 5(R1):Rc1/4 Piston R: Rc1/8 Note 1
Port size
Pilot Rc1/8
Lubrication Not required
Operating pressure range Main 0.17∼0.7 {1.7∼7.1} [25∼102]
MPa {kgf/cm2} [psi.] Pilot See the table “Minimum Pilot Pressure”
Proof pressure MPa {kgf/cm2} [psi.] 1.05 {10.7} [152]
Operating temperature range (atmosphere and media) °C[°F] 5∼60 [41∼140]
Shock Lateral direction 1373.0 {140.0}
m/s {G}
2
resistance Axial direction 912.0{93.0} 264.8{27.0} 912.0{93.0} 264.8{27.0}
Mounting direction Any
Maximum operating frequency Hz 5
Mass g [oz.] 110 [3.88] 135 [4.76] 110 [3.88](300 [10.58])Note 2 135 [4.76](325 [11.46])Note 2
Notes: 1. Port size of sub-base and manifold.
2. Figures in parentheses ( ) are the mass with sub-base.
Remarks: For optional specifications and order codes, see p.637∼638.
240-4A A240-4A-25
Load Load
Air-piloted valve A240-4A-25
0.5MPa
Cylinder
0.5MPa
Fitting TS10-02
Fitting TS10-02
1000 1000
800 800
φ40 [1.575in.] φ40 [1.575in.]
600 φ50 [1.969in.] 600 φ50 [1.969in.]
φ63 [2.480in.] φ63 [2.480in.]
400 400
φ80 [3.150in.] φ80 [3.150in.]
200 φ100 [3.937in.] 200 φ100 [3.937in.]
0 0
10 20 30 40 50 60 70 10 20 30 40 50 60 70
Load ratio % Load ratio %
1mm/s=0.0394in./sec.
0.6 0.6
Valve outlet pressure
0.5 0.5
0.7 Inlet Inlet
0.6
pressure 0.7 pressure
0.4 0.4 0.6
0.5 0.5
0.3 0.3
0.4 0.4
0.3 0.2 0.3
0.2
0.2 0.2
0.1 0.1
0.1 0.1
0 0
500 1000 1500 2000 500 1000 1500 2000
Flow rate R/min(ANR) Flow rate R/min(ANR)
1MPa=145psi.
1R/min.=0.0353ft3/min.
652
Operating Principles and Symbols
5-port, 2-position
240-4A 240-4A2
14(PA) 14(PA)
240-4A 240-4A2
Pilot connection port
Normal condition Actuated condition (Condition with pilot air applied to 12(PB),
and then released)
Piston
14(PA)
Body
Piston R
5(R1)
(R1)
5 5(R1)
4(A)
4(A) 4(A)
1(P)
1(P) 1(P)
2(B)
(B)
2 2(B)
3(R2)
3(R2) 3(R2)
Lip seal
Stem
End cover
12(PB)
653
Dimensions of Air-piloted Valves (mm)
●240-4A
23 Rc1/8 35 2-Piston R
Pilot connection port
2-Rc1/8
19.6
22
40
36
1(P)
35.5
25.7
24.5
2(B)
17.5
15.5
3(R2)
2 2 3-Rc1/4 8
9 9 3 3
7 7
●240-4A2
23 2-Rc1/8 35
2-Piston R
Pilot connection port
2-φ3.3 2-Rc1/8
Mounting
2-φ3.3 Counterbore R3 Depth 3 hole
Mounting hole
14(PA)
5(R1)
4(A)
19.6
22
36
40
88
1(P)
2(B)
44
34.2
3(R2)
33
26
24
12(PB)
3-Rc1/4
2 2 8 3 3
9 9
Options
(21)
108.8
11.4
5.6
B
1.6
10
Width across flats
2-φ4.5 R1/8
Mounting hole
35
18 18
46
654
Dimensions of Air-piloted Valves (mm)
●A240-4A-25
●A240-4A-27
43 82.5
9 23 11 38.5 43
21 35
Rc1/8
10 Pilot connection port 17.5 27.5
21
Rc1/8
Piston R
5(R1)
PR
4(A)
79.5
1(P)
68.5
21
58.5
A
55
40
2(B)
3(R2)
30
19.5
10
4.5
5.5
5-Rc1/4
34 4.5
2-φ4.5
Mounting hole
●A240-4A2-25
●A240-4A2-27
43 82.5
9 23 11 38.5 43
21 35
2-Rc1/8
10 Pilot connection port 17.5 27.5
21
Rc1/8
Piston R
14(PA)
5(R1)
PR
4(A)
A
1(P)
58.5
68.5
88
21
40
55
2(B)
3(R2)
30
19.5
12(PB)
4.5
14
10
5-Rc1/4
2-φ4.5 34 4.5
Mounting hole
5(R1)
PR
4(A)
14
Width across flats 1(P)
23
40
R1/4
55
3(R2)
30
18.5
2(B)
10
10.5
25
34.5
655
Handling Instructions and Precautions
Diode
※Illustration shows the 110 series.
PU
Color of LED indicator AC100V: Yellow SH
AC200V: Green
Crimping of connecting lead wire and contact
To crimp lead wires into contacts, strip off
●DC24V 4mm [0.16in.] of the insulation from the tip ※Illustration shows the 110 series.
of the lead wire, insert it into the contact,
Standard solenoid (Surge suppression) and crimp it. Be sure to avoid catching the Locking type
insulation on the exposed wire crimping
Short circuit protection diode section. To lock the manual override, use a small
(+) Exposed wire 4mm
Lead wire: Red Lead wire screwdriver to push down on the manual
Solenoid Contact Equivalent to override all the way down and turn it 45
AWG22∼26
Flywheel degrees. Either turning direction at this time
diode
(−) is acceptable.
Lead wire: Black When locked, turning the manual override
Insulation crimp tab from the locking position releases a spring
Insulation(Maximum on the manual override, returns it to its
Hook Exposed wire crimping section outer diameterφ1.7)
Solenoid with LED indicator normal position, and releases the lock.
(Surge suppression) Cautions: 1. Do not pull hard on the lead wire. When the manual override is not turned, this
Order code: -PS-L 2. Always use a dedicated tool for type acts just like the non-locking type.
-PL-L crimping of connecting lead wire
LED indicator and contact.
(Light Emitting Diode)
Contact: Model 702062-2M
(+) Manufactured by Sumiko Tech, Inc.
Lead wire: Red Crimping tool: Model F1-702062
Manufactured by Sumiko Tech, Inc.
(−) TURN
Lead wire: Black LED indicator: Red Attaching and removing contact and connector
Insert the contact with lead wire into a plug
connector □ hole until the contact hook
latches on the connector and is secured to
the plug connector. Confirm that the lead PU
SH
wire cannot be easily pulled out.
To remove it, insert a tool with a fine tip
(such as a small screwdriver) into the
rectangular hole on the side of the plug
※Illustration shows the 240 series.
connector to push up on the hook, and then
pull out the lead wire. Cautions: 1. The 240 series valves are pilot type
solenoid valves. As a result, the
manual override cannot switch the
main valve without air supplied from
the 1(P) port.
2. Always release the lock of the lock-
ing type manual overrides before
commencing normal operation.
3. Do not attempt to operate the
Cautions: 1. Do not pull hard on the lead wire. It manual override with a pin or other
could result in defective contacts, object having an extremely fine tip.
breaking wires, etc. It could damage the manual
2. If the pin is bent, use a small override button.
screwdriver, etc. to gently straighten 4. Do not turn the adjusting knob
out the pin, and then complete the more than needed. It could result in
connection to the plug connector. defective operation.
656
Handling Instructions and Precautions
Manifold
t y u e End plate A
240M□A(W)
r
240M□B(W)
657
Plug-in DIN connector
connection cover !0, and pull out the Plug Cable gland
Solenoid terminal
terminal block i. Socket Cable gasket location
Washer
Loosening the joint mounting bolts on both
Contact
sides and removing the joint lets the stations Lead wire
Lead wire
added, install the joint, and tighten the joint No. 2 terminal (−) Cover
mounting Terminal
Lead wire Terminal
Gasket body
mounting bolts. Then, fit the terminal block, screw cover Terminal body Pliers
secure the terminal cover in place with
mounting screws, and fit the connection Note: The appropriate tightening torque for the cover
No.1 terminal (+) mounting screw is 29.4N・cm {3kgf・cm}
cover. No. 2 terminal (+) [2.6in・lbf].
Bottom port
Since the B Type and BW Type manifolds Wiring instructions
have piping ports on the bottom of the In the plug-in type, the terminal block and
manifold, both the bottom and side ports can solenoid are connected by a plug and
be used as required. socket. Loosen the terminal cover mounting
screws, remove the terminal cover, and
●Piping port location then pull out the terminal block and connect
With the 1(P) port on both ends and the it. Fit the connected terminal block into the
bottom surface, the 4(A) and 2(B) ports on sub-base or manifold, mount the terminal
the side and bottom surfaces, and the 3(R2) cover, then secure the mounting screws in
and 5(R1) ports on both ends and the place.
bottom surface, piping is allowed in any Connect the single solenoid leads to the
location. Use the plugs provided with the No. 2 (+, −) terminal.
manifold, with sealing tape or another In the double solenoid, the No.1 (+, −)
sealing agent, to block off the unused ports. terminals are connected to the valve’s
solenoid 12 (S1), and the No.2 (+, −)
Port isolator terminals to the solenoid 14 (S2). For DC
models, pay attention to the polarity. While
Port isolators on the 1(P), 3(R2) and a wrong in polarity will not cause a short
5(R1) ports can be used to separate them circuit, the valve will not operate.
from adjacent stations, to allow supply of For the terminal, use the round terminal
different pressures, or to prevent exhaust JIS2805 R type 1.25-3 or equivalent.
interference. To order the terminal block and other parts
Port isolators can be fitted and assembled for adding units, see the manifold parts
between stations in place of the O-rings y order item on p.657. A collective common
to separate the 1(P), 3(R2) and 5(R1) ports type manifold that uses crossover contacts
from adjacent stations. For stations split by can also be manufactured. Consult us.
port isolators, plumb the 1(P), 3(R2) and
5(R1) ports on the bottom.
Block-off plate
To close up the unused stations, use a
block-off plate (order code: -BP).
658