You are on page 1of 1

Preventice Mainteanance Plan M17 PD2.

- Checking and backup data accuracy 4 machine.


- Insulation resisitance tested 4 machine.
- Flushing hydraulics oil No.32 : 20 liter. CNC Lathe 1 machine.
- Cleaning all machine in production line.
- Machine working check : OK
- Check system working : electrical, pneumatics, hydraulics, cylinders etc.

#Remark
M1702 FANUC T10B : Y-axis is loudly when rotating.
- Overhaul by ball's alignment inside housing bearings.
- Testing after improvement is OK. (Tempolary repair)
M1702 FANUC T10B : Y-axis's insulations resistance are lower standard. U, V, W =
9.43 MOhm.
- Improvement by replace a new power cable.
- Testing after improvement is OK.

M1704 TAKAMAZ : Hydraulics oil was leaked from pump motor.


- Overhaul by replacement a new bearings's seal, o-ring, cleaning stator winding
and check system working.
- Testing after improvement is OK.

You might also like