You are on page 1of 2

General Trading & Oil services Co. LTD.

Trading | Oil Services | Supplies | Inspection

Daily report 30. April.2023

@08:30 Morning arriving to IOT yards by PetroVision team, Inventory quantity of total SSD in
IOT yard was 5 SSD with mention PN. In below table.
SSD No. Manufactured Serial Number Remark
SSD 1 Sledgehammer SH-CA-5082-004
SSD 2 Sledgehammer SH-CA-5082-021
SSD 3 Sledgehammer SH-CA-5082-022
SSD 4 Sledgehammer SH-CA-5082-023
SSD 5 Sledgehammer SH-CA-5082-025

preparing tools and place to start redressing and making assembly with PN. 004, the seal
of the upper sub was in good condition, but sleeve stuck inside of the lower sub., need to
remove it by B-shifting (Almansoori Slickline) waiting on slickline around 30 minutes then
racked side.
SSD PN. 025 redressed seal stack was in good condition and changed by new set of seal,
assembled and ready for function test.
SSD PN. 022 redressed seal stack was in good condition and changed by new set of seal,
assembled and ready for function test.
SSD PN. 023 opened the seal of upper sub was in good condition, but sleeve was stuck inside
of the lower sub, racked side.
SSD PN. 021 opened observed seal stack for upper sub was damage attached below picture.
Change seal stack with new set waiting around 30 minutes on Vise air and assembled, ready
for function test.
03:45 team left the location.

1
General Trading & Oil services Co. LTD.
Trading | Oil Services | Supplies | Inspection

Damage seal stack of SSD SH-CA-5082-021

Taha Abdulhameed

Service Engineer / Petro Vision

30.04.2023