3. MAINTENANCE WORK 341 Regular Inspection ‘Area to be (Checkpoints Procedure inspected __| Every day | Pressure Reading ofpressure | Adjust reading to be specified value Reducing valve | gauge should be correct. | (0.3 Mpa standart. atair inlet iain must not be Drain if accumulated. Accumulated more than limit level. Sludge retum line | Sludge and scum are | If either sindge or scum is not being and scum return | being returned, (Note | retumed, correct according to the line (NOTE 1) | thatthe returning scum | instructions in (NOTE 2) on page 11 isnot always flowing in the hose. It flows only when sewage flows into the Plant) Chlorination tablets |The height of tablets in| Remove the top vover, and fully Gil the inthe chlorinator | the cylinder needs to be | cylinder with the tablets. (NOTE 2) atleast 1/4 the height of cylinder. Every week | Residual chlorine | The residual chlorine | Ifthe residual chlorine concentration content in treated | concentration must fall_| exceeds 0.Sppm, control the amount of water ina range of Oto the tablets. 0.5ppm. Every month | Chlorinator ‘There must Be no Remove the ehlorinator and clean it (NOTE 3) blockage inthe cylinder. Discharge pump | Check the mechanical | If leakage rate is 0.5 ce/min or greater, seal for leakage. ‘make correction according to the instruction inthe instruction manual of the discharge pump. ~Areato be ‘Checkpoints Procedure inspected | Every 2103 | Aeration Discharging of excess | For 30 minutes, prohibit sewage from months compartment | sludge flowing into the Plant and keep the Plant inactive. Then, discharge approximately 75% of the mixture liquid inthe aeration compartment by running the discharge pump. Tris operation must be performed outside restricted waters. After discharging, fill the tank with wate, and restart the Plant. Check the interior sereen | Ifthe sereen has been fouled up or for fouling. ‘logged, clean it with freshwater or clean seawater Clarification | Check the inside for __ | Ifthe inside is fouled up, clean with compartment | fouling. freshwater of clean seawater Every years | Tank, discharge | Inspect the inside of the | Discharge the wastes, and clean the pump tank, as well asthe | inside. Then, inspect each area. Ifa components onthe _| problem is found, repair or replace. accessories. Pressure Filter shall not be Clean if cogged. reducing valve | clogged. [Every3 years Inside ofthe tank | Damaged coating layer | Repair the damaged area with the inside the tank. coating. -10-

You might also like