You are on page 1of 12

Engineers Training on

Design for Seismic Retrofitting of Masonry


Building
5-9 August 2019, Lalitpur, Nepal

Introduction to Computer Aided Retrofit Design


using SAP: Shear

Organized By:
National Society For Earthquake
Technology- Nepal (NSET)

Earthquake Safe Communities in Nepal


Objectives of the Session

Upon Completion of this session, the participants


should be able to

• Learn computer aided analysis of Masonry Building


in Shear

Earthquake Safe Communities in Nepal 2


In-plane shear stress

Maximum in-plane
shear stress =
0.334 N/mm2

Earthquake Safe Communities in Nepal


Shear stress distribution

Solid Wall

Wall with Opening

Earthquake Safe Communities in Nepal


8/8/2019 Type your presentation theme - edit to put title on Insert/header & footer

Earthquake Safe Communities in Nepal 5


8/8/2019 Type your presentation theme - edit to put title on Insert/header & footer

Earthquake Safe Communities in Nepal 6


8/8/2019 Type your presentation theme - edit to put title on Insert/header & footer

Earthquake Safe Communities in Nepal 7


Splint and bandage
system

Bandage

Splint

Earthquake Safe Communities in Nepal


Jacketing on remaining walls using G.I. wire
200mm width on each sides of corners of 14SWG (2.03mm ∅) @ 100mm c/c both
and junctions using 3-8mm∅ bars horizontally and vertically for Local failure
300mm width for sides of openings
9
using 2-8mm∅ + 1-4.75mm∅ bars
Earthquake Safe Communities in Nepal
Horizontal Bands

·200mm width using 2-4.75mm∅ bars at sill level


·300mm width using 3-4.75mm∅ bars at lintel level
10

Earthquake Safe Communities in Nepal


Objectives of the Session

Upon Completion of this session, the participants


should be able to

• Learn computer aided analysis of Masonry Building


in Shear

Earthquake Safe Communities in Nepal 11


Thank you!

12

Earthquake Safe Communities in Nepal

You might also like