Accumulator Technology.

EN 3.000.18/04.21
1. HYDAC ACCUMULATOR TECHNOLOGY
FLUID ENGINEERING EFFICIENCY VIA ENERGY MANAGEMENT.
HYDAC Accumulator Technology has
many years’ experience in the research &
development, design and production of
hydraulic accumulators.
All of HYDAC’S bladder, piston, diaphragm
and metal bellows accumulators are part of
an unbeatable product range which
supports hydraulic systems in almost all
sectors at a component or unit level.

The main applications of our accumulators


are:
z Energy storage
z Emergency and safety functions
z Damping of vibrations, fluctuations,
pulsations (pulsation dampers), shocks
(shock absorbers) and noise (silencers)
z Suction flow stabilisation
z Media separation
z Volume and leakage oil adjustment
z Weight equalisation
z Energy recovery

Accumulators improve the performance of


the entire system. Here are some of their
advantages in more detail:
z Improved functions
z Increased service lives
z Reductions in operating and
maintenance costs
z Reductions in pulsations and noise

On the one hand, this means greater


safety and comfort for the operator and the
machine.
On the other hand, HYDAC accumulators
enable efficient working in all applications.
2. QUALITY In conjunction with the customer service
department at HYDAC's headquarters,
Basic criteria, such as the: Quality, safety and reliability are paramount service is possible worldwide.
z Design pressure, for all HYDAC accumulator components.
HYDAC's worldwide distributor network
z Design temperature, They comply with the current regulations means that trained staff are close at hand
(or standards) for pressure vessels in the to help our customers.
z Fluid displacement volume, individual countries of installation.
z Discharge / charging velocity, HYDAC customers can therefore
z Fluid, be assured to receive a high-quality This ensures that HYDAC customers have
accumulator product which can be used in the support of an experienced workforce
z Acceptance specifications and
every country in the world, depending on both before and after sale.
z Mounting options the certification.
are all important parameters which enable For more details, please turn to section 4.
the correct accumulator size to be chosen.
Our accumulator specialists will also use
their technical expertise to help you select All the processes involved, from
the right type of accumulator. The development, engineering and production
comprehensive range of HYDAC to approval and delivery are defined by
accessories simplifies installation and HYDAC's certified management system
maintenance according to the and the relevant international accreditation
specification. for the manufacture of pressure vessels.
EN 3.000.18/04.21

2
Catalogue
CONTENTS Page section

1. HYDAC ACCUMULATOR TECHNOLOGY 2 EN 3.000

2. QUALITY 2

3. SAFETY INFORMATION 4

4. REGULATIONS 5

5. PRODUCT OVERVIEW 6–8

5.1. BLADDER ACCUMULATORS

5.1.1 Low pressure EN 3.202

5.1.2 Standard design EN 3.201

5.1.3 High pressure EN 3.203

5.2. PISTON ACCUMULATORS

5.2.1 Standard design EN 3.301

5.2.2 Series SK280 EN 3.303

5.2.3 High pressure EN 3.302

5.3. DIAPHRAGM ACCUMULATORS EN 3.100

5.4. METAL BELLOWS ACCUMULATORS EN 3.304

5.5. HYDRAULIC DAMPERS EN 3.701

5.6. SPECIAL ACCUMULATORS

5.7. ACCUMULATOR STATIONS EN 3.653

5.8. ACCUMULATOR ACCESSORIES

5.8.1 Hydraulic accumulators with back-up nitrogen bottles EN 3.553

5.8.2 Charging and testing unit EN 3.501

5.8.3 Safety and shut-off block EN 3.551

5.8.4 Safety equipment for accumulators EN 3.552

5.8.5 Mounting elements for hydraulic accumulators EN 3.502

5.8.6 ACCUSET SB EN 3.503

6. INDUSTRIES AND APPLICATIONS 9 – 10

7. / 8. WEBSITE / SPECIFICATION FORMS 10 – 16


EN 3.000.18/04.21

9. SIZING 17 – 18

10. NOTE 18

3
3. SAFETY INFORMATION Manufacturers of hydraulic accumulators 3.1. RISK OF EXCESSIVE
and products with hydraulic accumulators
Hydraulic accumulators are closed vessels must observe the following principles: PRESSURE
that are designed and built to hold Products:
pressurised fluids. They are charged with z Removal or reduction of risks, insofar as
nitrogen which is separated from the fluid this is reasonably possible Safety and shut-off block for the fluid side
section by a piston, bladder or diaphragm. z Implementation of appropriate protective in various sizes and designs.
Hydraulic accumulators are specifically measures against risks which cannot be See catalogue section:
designed to store and then discharge eliminated z SAF/DSV safety and shut-off block
pressurised fluids. z If required, user training regarding any No. 3.551
The regulations for the commissioning and residual risks and the appropriate special Gas safety valve and gas safety block for
operating of hydraulic accumulators which measures for reducing these risks during the gas side
are in force at the place of installation must installation and/or operation.
be observed. The plant operator is solely Burst discs for gas and fluid sides
For safe handling and operation, the
responsible for ensuring compliance with See catalogue section:
operator must draw up a risk assessment
these regulations. for the installation site which focuses on z Safety equipment for
Relevant instructions are provided in the the interaction with other components and hydraulic accumulators
operating instructions for our products. risks. No. 3.552
The measures which result from this 3.2. RISK OF RISE IN
risk assessment must be implemented
accordingly. TEMPERATURE
In the case of fundamental risks affecting Products:
hydraulic accumulators, e.g. Safety and Shut-off Block with solenoid-
z Excessive pressures operated valve (open when de-energised)
in conjunction with temperature monitoring.
z Increases in temperature (in the event
of fire) See catalogue section:
we already have the relevant products z SAF/DSV safety and shut-off block
available. No. 3.551 or on request
On no account must any welding, soldering Temperature fuses
or mechanical work be carried out on the See catalogue section:
accumulator. After the hydraulic line has z Safety equipment for
been connected, it must be completely hydraulic accumulators
vented. Work on systems with hydraulic No. 3.552
accumulators (repairs, connecting
pressure gauges etc.) must only be carried
out once the fluid pressure has been
released.
EN 3.000.18/04.21

4
4. REGULATIONS 4.2.2 C ERTIFICATE CODE = P European member states Certificate
(KHK certificate) and EFTA states code (CC)
4.1. EUROPEAN PRESSURE For the Japanese market, HYDAC Austria
EQUIPMENT DIRECTIVE Technology GmbH has had approval as
Belgium
a "Self Inspecting Manufacturer" since
(PED) the year 2000. Consequently, HYDAC Bulgaria
The European Directive 2014/68/EU is authorised to manufacture and test Cyprus
came into effect in July 2016. It replaces pressure vessels for the Japanese market Czech Republic
Directive 97/23/EC and governs the and to import them into Japan. Denmark
design, fabrication, conformity assessment Estonia
and placing on the market of pressure 4.2.3 C
 ERTIFICATE CODE = A9
(MANUFACTURER LICENSING Finland
equipment and assemblies with a CHINA)
maximum permitted pressure of more than France
Since 1998 HYDAC Technology GmbH Germany
0.5 bar. It guarantees free movement of has had approval from the Chinese
goods within the European Community. Great Britain
authority "SELO" as a manufacturer of
The EU member states are not permitted pressure vessels and valves. Greece
to prohibit, restrict or hinder pressure Hungary
equipment being placed on the market and 4.2.4 C ERTIFICATE CODE = A11 Iceland
put into service on the basis of pressure- (KGS code) Ireland
related risks, provided that the equipment Since concluding the registration U
in question meets the requirements of the procedure in 2012, HYDAC Technology Italy
European Pressure Equipment Directive, GmbH is authorised to supply pressure Latvia
has undergone a conformity assessment vessels and safety equipment according Lithuania
and is labelled with a CE marking. to the Korean Gas Safety (KGS) Code for Luxembourg
Hydraulic accumulators with a capacity of Korea. Malta
V ≤ 1 l and a maximum permitted pressure 4.2.5 CERTIFICATE CODE = A6 Netherlands
PS ≤ 1000 bar or a pressure capacity (TR-CU) Norway
PS • V ≤ 50 bar • l for gases of fluid group Since 2014, the TR‑CU 032/2013 Poland
2 (non-hazardous fluids) are subject regulation (technical regulation of the Portugal
to Article 4, section 3 of the European customs union "on the safety of pressure Romania
Pressure Equipment Directive and do not equipment") has applied for the countries
receive the CE marking. Slovakia
of the Eurasian Economic Community.
Slovenia
Inspection, installation, operational safety HYDAC Technology GmbH has been
and repeat testing of equipment are Spain
certified in accordance with the regulation
controlled as before by national laws. to supply its product range. Sweden
The equipment relating to safety is Switzerland
described in AD2000, ISO 4126 and
4.3. CERTIFICATE TABLE
EN 14359. The following table lists the codes
The repeat testing intervals are stipulated recommended for use in the model code A selection of other Certificate
in the new German industrial health and for different countries of installation. countries code (CC)
safety regulations. The country of installation must be stated Australia F 1)
at the time of ordering (see code in Model Belarus A6
4.2. OTHER REGULATIONS Code for the particular product: Canada S1 1)
Pressure accumulators which are installed Certificate Code). China A9
overseas (outside the EU) are supplied Countries not included in the list may Hong Kong A9
with the relevant test certificates required be possible on request. Alternative test
in the country of installation. Japan P
certificates and differing values may also Korea (Republic) A11
HYDAC pressure vessels can be supplied be possible on request.
with virtually any test certificate. New Zealand T
Russia A6
Depending on the authority, different
South Africa S2
material requirements must be observed
Turkey U
Details of some selected approvals are as
Ukraine A10
follows:
USA S
4.2.1 CERTIFICATE CODE = S (ASME) Registration required in the individual territories or
1)
Since 1985, HYDAC Technology GmbH provinces
has been authorised to label pressure Others on request.
equipment that has been manufactured in
compliance with the ASME regulations with 4.4. TRANSPORT
the "ASME" certification mark. REGULATIONS FOR
PRESSURE VESSELS
The transport of gas-filled hydraulic
accumulators must be carried out with
the utmost care and in compliance with
all relevant transport safety regulations
Such pressure equipment may be (e.g. on public roads, dangerous goods
placed on the market in the jurisdiction regulations, etc.).
(application area) of the National Board of
Boiler and Pressure Vessel Inspectors. The operating instructions must be
observed!
EN 3.000.18/04.21

5
5. PRODUCT OVERVIEW
The following overview shows the standard product range of HYDAC hydraulic accumulators.
For other models and sizes, please contact us.
5.1. BLADDER
ACCUMULATORS
5.1.1 Low pressure Advantages of HYDAC bladder
Permitted operating pressure: accumulators:
up to 40 bar z High discharge speeds
Nominal volume: z No pressure difference between fluid
2.5 ... 450 l side and gas side
z Compact, low-maintenance
z High charge and discharge frequencies

5.1.2 Standard design


Permitted operating pressure:
up to 550 bar
Nominal volume:
0.5 ... 200 l

5.1.3 High pressure


Permitted operating pressure:
up to 1000 bar
Nominal volume:
1 ... 50 l
Other volumes on request

5.2. PISTON ACCUMULATORS


5.2.1 Standard design Advantages of HYDAC piston
Permitted operating pressure: accumulators:
210 ... 350 bar z Minimal pressure difference between
Nominal volume: fluid side and gas side
up to 3300 l z Large effective volumes
z Variable installation positions
z Monitoring of the piston position is
possible using a variety of systems
z Particularly suitable for back-up
5.2.2 Series SK280 configurations
Permitted operating pressure:
z Extreme flow rates
280 bar
z No sudden discharge of gas when seals
Nominal volume:
are worn
0.16 ... 15 l
Other volumes on request

5.2.3 High pressure


Permitted operating pressure:
up to 1000 bar
Nominal volume:
up to 50 l

5.3. DIAPHRAGM
ACCUMULATORS
5.3.1 Diaphragm accumulators Advantages of HYDAC diaphragm
Weld and screw type accumulators:
Permitted operating pressure: z Function-optimised and weight-optimised
up to 750 bar design
EN 3.000.18/04.21

Nominal volume: z Unlimited choice of installation positions


up to 4 l z No pressure difference between fluid
side and gas side
z Low-maintenance and long service life

6
5.4. METAL BELLOWS
ACCUMULATORS
5.4.1 Metal bellows accumulators Advantages of the HYDAC metal
Please contact us bellows accumulator:
z Durable
z Wear-free
z Media resistance over a wide range of
temperatures
See also flyer:
z Heavy diesel engines -
Metal bellows accumulators
No. 10.129.1
5.5. HYDRAULIC DAMPERS
5.5.1 Dampers Advantages of the HYDAC hydraulic
Permitted operating pressure: damper:
10 ... 1000 bar z Reduces pressure pulsations
Nominal volume: z Improves the suction performance of
0.075 ... 450 L displacement pumps
z Prevents pipe breaks and damage to
valves
z Protects measuring equipment and its
function in the system
z Reduces noise level in hydraulic
5.5.2 Silencers systems
Permitted operating pressure:
330 bar z Lowering of servicing and maintenance
Others on request costs
z Increase in service life of the system

5.6. SPECIAL
ACCUMULATORS
5.6.1 Weight-reduced See also flyer:
accumulators z Weight-reduced accumulators
Over 80 % reduction in weight No. 3.305
compared to equivalent
carbon steel accumulators.
The selection ranges from weight-
optimised accumulators, e.g. by using
aluminium, through to light-weight and ultra
light-weight accumulators.

5.6.2 Spring accumulators Advantages of the HYDAC spring


Fitted with a spring. accumulator:
The energy is produced by the spring z No gas losses
force, instead of gas.
z Linear p-V characteristic curve
Further information on request.
z Functionality is independent of
temperature influences

5.7. ACCUMULATOR
STATIONS
HYDAC supplies fully assembled
accumulator stations which are ready for
operation, complete with all the necessary
valve controls, pipe fittings and safety
devices
z as an individual accumulator unit or
z in a back-up version with
nitrogen bottles to
increase the effective
volume.
EN 3.000.18/04.21

7
5.8. ACCUMULATOR
ACCESSORIES
5.8.1 Hydraulic accumulators with Advantages of using HYDAC nitrogen
back-up nitrogen bottles bottles:
HYDAC also offers nitrogen bottles which z Inexpensive increase of accumulator
can be used to back up bladder and piston volume
accumulators. Nitrogen bottles used as
back-ups increase the gas volume in the z This leads to smaller accumulators with
accumulator. the same gas volume

5.8.2 FPU Further products related to "charging


Charging and testing unit and testing" are available in the nitrogen
Charging hose, pressure gauge and charging units (N2 servers) section – see
pressure reducer for HYDAC and other catalogue section:
brands of accumulator, up to 800 bar pre- z Nitrogen charging units N2-Server
charge pressure – higher pressures on No. 2.201
request.
Portable, mobile and stationary versions
are available.
We are always happy to give advice.

5.8.3 SAF/DSV Advantages of the HYDAC safety and


Safety and shut-off block shut-off block:
Nominal size: z Minimal space requirements and
8 ... 50 maintenance costs
Permitted operating pressure: z Minimal pipework required
800 bar (as a rule, 1 SAF replaces up to 10
Fluid-side protection, pressure relief valve, individual pipe connections)
unloading to tank and separation of the z Considerable reduction in installation
accumulator from the fluid-side system. time
z Can be adapted to different types and
different brands of accumulator
z Can be adapted to additional valves
(pilot-operated check valves, flow control
valves, etc.).
5.8.4 Safety devices Advantages of the HYDAC gas safety
z GSV6 gas safety valve block:
z Temperature fuse z A gas safety block simplifies the
z Burst disc operation of the hydraulic accumulator
on the gas side and also offers the
z Gas safety block possibility of installing the above safety
All of the above are safety equipment for equipment using the various ports.
HYDAC accumulator products.

5.8.5 Monitoring systems for hydraulic See also flyer:


accumulators z Monitoring systems for
z Bladder integrity system hydraulic accumulators
z Piston position monitoring systems No. 3.506
z Pre-charge pressure monitoring

5.8.6 Mounting elements for Please make use of our online tool
hydraulic accumulators Accu‑MOUNT to help you select the
Accumulator mounting sets, clamps suitable mounting equipment for your
and consoles for efficient installation of hydraulic accumulator
hydraulic accumulators. www.hydac.com " Service "
Online tools

5.8.7 ACCUSET SB
Permitted operating pressure:
330 bar
Nominal volume:
EN 3.000.18/04.21

1 ... 50 l

8
6. INDUSTRIES AND 6.1. STATIONARY HYDRAULICS
APPLICATIONS Automotive industry
HYDAC Technology GmbH is z General industrial hydraulics,
represented in almost all industries e.g. energy storage
of the world which use hydraulic
accumulators.
The main sectors are industrial
hydraulics, mobile technology and Mining machinery
process technology.
z Hydraulic accumulators,
Further applications in the oil & e.g. in suspended monorails
gas/offshore industry and energy
efficient applications involving z Pulsation damping
hydraulic accumulators are gaining in z Comfort and safety for mobile working machines
importance.
The following list summarises the ways Iron and steel industry
that accumulators/dampers are typically z Accumulator to maintain the pressure in rolling
used in these industries: mills
z Blast furnace hydraulics

Plastics machinery
z Accumulator stations for energy storage during
the injection moulding process
z Pulsation damping on the hydraulic drive

Paper industry
z Energy storage for emergency functions in
friction bearing hydraulics
z Energy storage in high/low pressure power units

Test rigs and test systems


z Energy storage on crash test systems
z Pulsation damping on servo hydraulic axes

Thermal power plants


z Emergency supply for turbine control system
z Pulsation damping on pumps
z Lubrication, control and seal oil supply

Forming machines
z Hydraulic accumulators used to store energy to
support the pump

Machine tools
z Support for the hydraulics for tool drive or tool
change
z Energy storage in the compact hydraulics of
machining centres

Wind turbines
z Hydraulic accumulators in the pitch control
system
z Support of the pitch drive
z Accumulators on braking units
EN 3.000.18/04.21

9
6.2. MOBILE TECHNOLOGY 6.3. PROCESS TECHNOLOGY
Automotive technology Chemical industry
z Automatic and manual transmission z Energy storage and pulsation damping on dosing
z Automatic clutch systems pumps
z Engine management systems z Suction flow stabilisation on the suction side of pumps
z Accumulators for turbocharger emergency
lubrication
Loading stations / refineries
Construction machines z Shock absorption for valve closing
z Accumulators in braking systems z Pulsation damping on piping
z Chassis damping
z Bucket damping
z Boom damping on mobile cranes Offshore / Oil & Gas
Agricultural and forestry machines z Accumulators to support valve closing systems
z Front loader damping z Energy storage for deep sea rams
z Accumulators in tractor suspension z Blow Out Preventers (BOP)
systems z Emergency function for safety systems
z Stone strike protection for ploughs z Accumulators on wellhead control systems
z Boom suspension on field sprayers
Pipeline construction
Municipal machines z Energy storage for emergency actuation of valve
z Energy storage stations
z Boom damping z Compressor stations
z Pulsation dampers
z Chassis damping

Lifting & material handling technology


z Noise damping
z Energy recovery
z Braking systems

Shipping
z Water treatment plants
(pump support)
z Pulsation damping on diesel engines
z Heave compensation (cranes)
z Emergency function for lifeboats

7. WEBSITE
Please visit us at the following address:
www.hydac.com.
In addition to industries, services and fluid engineering,
you will find the standard product range and the
comprehensive range of HYDAC accessories at
Products » Hydraulic Accumulators
Under Downloads you will find this product catalogue
in different languages in PDF format as well as other
information on HYDAC accumulator products (e.g.
operating, installation and repair instructions).
You can find the required product via the product search
tab and download the relevant CAD model.
Our online tool ASPlight facilitates quick and simple
input, calculation and evaluation of the required
accumulator parameters – see section 9.3.
Further tools, such as the p0‑calculator or
Accu‑MOUNT, can also be found at the same location.

8. SPECIFICATION FORM
Our aim is to provide optimal customer service both
before and after the accumulator is purchased.
The following specification forms are designed to
help pre-select the required accumulator/damper or
accessories.
EN 3.000.18/04.21

The specification forms are available in PDF format


from the download section under
Products » Hydraulic Accumulators.
The areas highlighted in green constitute the minimum
information required for a response or calculation.

10
GENERAL ACCUMULATOR SPECIFICATION FORM (Page 1/2)
(Subject to technical modifications, mandatory field)

Company: Location:

Surname, first name: Project name:

E-mail: Requirement: pieces/year

Telephone no.: as ¨ spare part


¨ original equipment

Accumulator type Fluids/medium Further information

¨ Bladder accumulator Fluid Industry

¨ Piston accumulator

¨ Diaphragm accumulator Density Country of installation

¨ Metal bellows accumulator Min. °C kg/m²

¨ Max. °C kg/m² Approval

Viscosity at 20 °C
System data
cSt Specification
Operating pressure
Viscosity at operating temperature
Min. bar Max. bar
cSt
Pre-charge pressure at 20 °C (nitrogen) 1)
Fluid demand diagram
bar
Additional information ¨ ONE pump and ONE consumer
Ambient temperature
Installation dimensions (height x Øa) Accumulator discharge rate
Min. °C Max. °C
mm l/min
Operating temperature
Fluid port Accumulator discharge time
Min. °C Max. °C
¨ Flange s
Complete cycle time
¨ Thread Flow rate of the pump
s
Gas port l/min

Material of the accumulator 2) ¨ M28x1.5 ¨ 7/8-14UNF ¨ Pump runs continuously

Accumulator shell ¨ ¨ Pump starts after discharge

Coating/finish
¨ SEVERAL pumps and/or
Fluid port ¨ Internal consumers (see sheet 2, incl.
example)
¨ External

Elastomer

1)
See catalogue section No. 3.000,
section on sizing
2)
Dependent on operating temperature and/or fluid
resistance
Remarks:

HYDAC Technology GmbH


EN 3.000.18/04.21

Industriegebiet
66280 Sulzbach/Saar, Germany
Tel.: +49 (0) 68 97 / 509 - 01
Fax: +49 (0) 68 97 / 509 - 464
Spare parts/accessories are available at www.hydac.com " Products " Hydraulic Internet: www.hydac.com
accumulators e-mail: speichertechnik@hydac.com
11
GENERAL ACCUMULATOR SPECIFICATION FORM (Page 2/2)
(Subject to technical modifications, mandatory field)

Fluid demand diagram for several pumps and/or consumers:

Qv = Consumer flow rate [l/s]


EV = Switch-on time of consumer [s]
AV = Switch-off time of consumer [s]
EP = Switch-on time of pump [s]
AP = Switch-off time of pump [s]

Number of consumers Number of pumps

QV1= EV1= AV1= QP1= EP1= AP1=

QV2= EV2= AV2= QP2= EP2= AP2=

QV3= EV3= AV3= QP3= EP3= AP3=

QV4= EV4= AV4= QP4= EP4= AP4=

Q
[l/s]

Time [s]

Example

EV1 AV1 EV2 AV2 EV3 AV3 EV4 AV4

Q
[l/s] Consumers

QV1 QV3
QV4
QV2
Time [s]
HYDAC Technology GmbH
EN 3.000.18/04.21

Industriegebiet
66280 Sulzbach/Saar, Germany
Tel.: +49 (0) 68 97 / 509 - 01
Pumps Fax: +49 (0) 68 97 / 509 - 464
EP1 AP1 EP2 AP2
Internet: www.hydac.com
e-mail: speichertechnik@hydac.com
12
SHOCK ABSORBER SPECIFICATION FORM (sheet 1/2)
(Subject to technical modifications, mandatory field)

Company: Location:

Surname, first name: Project name:

E-mail: Requirement: pieces/year

Telephone no.: as ¨ spare part


¨ original equipment

Accumulator type Fluids/medium Further information

¨ Bladder accumulator Fluid Industry

¨ Piston accumulator

¨ Diaphragm accumulator Density Country of installation

¨ Metal bellows accumulator Min. °C kg/m²

¨ Max. °C kg/m² Approval

Viscosity at 20 °C
System data
cSt Specification
Operating pressure
Viscosity at operating temperature
Min. bar Max. bar
cSt
Pre-charge pressure at 20 °C (nitrogen) 1)
Pump data
bar
Additional information Zero-delivery head
Ambient temperature
Installation dimensions (height x Øa) m
Min. °C Max. °C Pressure of the pump at the operating
mm point
Operating temperature
Fluid port bar
Min. °C Max. °C
Flow rate of the pump at the operating
¨ Flange
point
Complete cycle time
¨ Thread
s l/min
Gas port
Cause of the pressure shock
Material of the accumulator 2)
¨ M28x1.5 ¨ 7/8-14UNF
¨ When pump starts
Accumulator shell ¨
¨ When pump switches off
Coating/finish
¨ When check valves close
Fluid port ¨ Internal
¨
¨ External
Elastomer
Pipe data
Please provide pipe data on the next
page.
1)
See catalogue section No. 3.000,
section on sizing
2)
Dependent on operating temperature and/or fluid
resistance
Remarks:

HYDAC Technology GmbH


EN 3.000.18/04.21

Industriegebiet
66280 Sulzbach/Saar, Germany
Tel.: +49 (0) 68 97 / 509 - 01
Fax: +49 (0) 68 97 / 509 - 464
Spare parts/accessories are available at www.hydac.com " Products " Hydraulic Internet: www.hydac.com
accumulators e-mail: speichertechnik@hydac.com
13
SHOCK ABSORBER SPECIFICATION FORM (sheet 2/2)
(Subject to technical modifications, mandatory field)

General pipe data

Material of pipe Total closing time of the valve s

Max. permitted pressure of the pipe bar Speed of sound in the system m/s

Information on pipe sections


L = Length of the pipe [m]
Di = Internal diameter of the pipe [mm]
S = Wall thickness of pipe [mm]
H = Zero head of the pump [m]
T = Closing time of the valve [s] (effectively roughly 30 % of the total closing time)

Number of different pipes

L1 = m D i1 = mm S1 = mm L4 = m D i4 = mm S4 = mm

L2 = m D i2 = mm S2 = mm L5 = m D i5 = mm S5 = mm

L3 = m D i3 = mm S3 = mm L6 = m D i6 = mm S6 = mm

Example

HYDAC Technology GmbH


EN 3.000.18/04.21

Industriegebiet
66280 Sulzbach/Saar, Germany
Tel.: +49 (0) 68 97 / 509 - 01
Fax: +49 (0) 68 97 / 509 - 464
Internet: www.hydac.com
e-mail: speichertechnik@hydac.com
14
PULSATION DAMPER SPECIFICATION FORM
(Subject to technical modifications, mandatory field)

Company: Location:

Surname, first name: Project name:

E-mail: Requirement: pieces/year

Telephone no.: as ¨ spare part


¨ original equipment

Accumulator type Fluids/medium Further information

¨ Bladder accumulator Fluid Industry

¨ Piston accumulator

¨ Diaphragm accumulator Density Country of installation

¨ Metal bellows accumulator Min. °C kg/m²

¨ Max. °C kg/m² Approval

Viscosity at 20 °C
System data
cSt Specification
Operating pressure
Viscosity at operating temperature
Min. bar Max. bar
cSt
Pre-charge pressure at 20 °C (nitrogen) 1)
Pump and system data
bar
Additional information Operating/pump pressure
Ambient temperature
Installation dimensions (height x Øa) bar
Min. °C Max. °C
mm Flow rate
Operating temperature
Fluid port l/min
Min. °C Max. °C
¨ Flange Rotational speed
Complete cycle time
¨ Thread 1/min
s
No. of displacement
Gas port elements
Material of the accumulator 2)
¨ M28x1.5 ¨ 7/8-14UNF ¨ single ¨ double acting
Accumulator shell ¨ Pump factor optional
Coating/finish Stroke volume
Fluid port ¨ Internal for piston pump

¨ External d = Ø piston mm
Elastomer Application
H = stroke length mm
¨ pressure side ¨ suction side for diaphragm pumps,
see manufacturer’s specifications
Required residual pulsation % 1)
See catalogue section No. 3.000,
section on sizing
2)
Dependent on operating temperature and/or fluid
Result l gas volume resistance
Remarks:

HYDAC Technology GmbH


EN 3.000.18/04.21

Industriegebiet
66280 Sulzbach/Saar, Germany
Tel.: +49 (0) 68 97 / 509 - 01
Fax: +49 (0) 68 97 / 509 - 464
Spare parts/accessories are available at www.hydac.com " Products " Hydraulic Internet: www.hydac.com
accumulators e-mail: speichertechnik@hydac.com
15
VOLUME COMPENSATION SPECIFICATION FORM
(Subject to technical modifications, mandatory field)

Company: Location:

Surname, first name: Project name:

E-mail: Requirement: pieces/year

Telephone no.: as ¨ spare part


¨ original equipment

Accumulator type Fluids/medium Further information

¨ Bladder accumulator Fluid Industry

¨ Piston accumulator

¨ Diaphragm accumulator Density Country of installation

¨ Metal bellows accumulator Min. °C kg/m²

¨ Max. °C kg/m² Approval

Viscosity at 20 °C
System data
cSt Specification
Operating pressure
Viscosity at operating temperature
Min. bar Max. bar
cSt
Pre-charge pressure at 20 °C (nitrogen) 1) Pipe data for
Volume expansion coefficient shut-off system section
bar
1/°C Pipe volume
Ambient temperature
l
Min. °C Max. °C
Additional information Max. shut-off pressure
Operating temperature
Installation dimensions (height x Øa) bar
Min. °C Max. °C
mm Pipe material
Temperature rise time
Fluid port
min
¨ Flange Permitted pressure with accumulator
Material of the accumulator 2) ¨ Thread bar
Accumulator shell Gas port Pipe temperature
¨ M28x1.5 ¨ 7/8-14UNF Min. °C Max. °C
Fluid port ¨

Coating/finish

Elastomer ¨ Internal

¨ External
1)
See catalogue section No. 3.000,
section on sizing
2)
Dependent on operating temperature and/or fluid
resistance
Remarks:

HYDAC Technology GmbH


EN 3.000.18/04.21

Industriegebiet
66280 Sulzbach/Saar, Germany
Tel.: +49 (0) 68 97 / 509 - 01
Fax: +49 (0) 68 97 / 509 - 464
Spare parts/accessories are available at www.hydac.com " Products " Hydraulic Internet: www.hydac.com
accumulators e-mail: speichertechnik@hydac.com
16
9. SIZING
9.1. DEFINITION OF VARIABLES FOR SIZING A HYDRAULIC ACCUMULATOR
Function Limits for gas pre-charge pressure
Bladder accumulators
p0 ≤ 0.9 • p1
with a permitted pressure ratio of
p2 : p0 ≤ 4 : 1

For HYDAC low pressure accumulators, the following must also be taken into account:
Type SB40: p0 max = 20 bar
Type SB35H: p0 max = 10 bar

 ‚ ƒ
Piston accumulators
p0,tmin ≥ 2 bar

 ‚ ƒ
Diaphragm accumulators
a) Permitted pressure ratio: p2 : p0
Weld type:
The pressure ratio of weld-type diaphragm accumulators is between
4 : 1 and 8 : 1, depending on the design – see catalogue section
Diaphragm Accumulators, No. 3.100, section 3.1.
Screw type:
All sizes: 10 : 1
Other pressure ratios on request
 ‚ ƒ b) p0 ≤ 0.9 • p1
Metal bellows accumulators
(e.g. corrugated bellow version)
The max. permitted or optimal pre-charge pressure of a metal bellows accumulator
(with corrugated or diaphragm bellows) must be determined for each application and
each design version by providing information on the particular operating conditions and
consulting with HYDAC.

 ‚ ƒ
The specified values are maximum values and must not be considered as referring to a prolonged load. The tolerable pressure ratio is
influenced by the geometry, temperature, fluid, flow rate and gas losses caused by physical properties.
 The accumulator is pre-charged with nitrogen. The separating element (piston, bladder, diaphragm, metal bellows) shuts off the
fluid port.
‚ Temperature effects must be taken into account when choosing the minimum operating pressure. The minimum operating pressure
must also be higher than the gas pre-charge pressure (p1 > p0). This should prevent the separation element from striking the fluid
port every time fluid is discharged.
EN 3.000.18/04.21

ƒ Once the max. operating pressure is reached, the effective volume ΔV is available in the accumulator:
p0 = pre-charge pressure V0 = effective gas volume t0 = pre-charge temperature
p1 = minimum operating pressure V1 = gas volume at p1 tmin = min. operating temperature
p2 = maximum operating pressure V2 = gas volume at p2 tmax = max. operating temperature

17
9.2. SELECTING THE PRE- 9.3. ONLINE TOOLS
CHARGE PRESSURE The following HYDAC online tools are available at:
The selection of the pre-charge pressure www.hydac.com " Service " Online tools
defines the accumulator capacity. In 9.3.1 ASPlight
order to obtain optimum utilisation of the ASPlight is an intelligent application
accumulator volume, the following pre- which takes real gas behaviour into
charge pressures are recommended: account It enables you to calculate
9.2.1 Recommended values all the necessary parameters such as
For energy storage: pressure, volume and temperature
in different units for gases such
p0,t max = 0.9 • p1 as nitrogen or helium. Additional
information fields help to evaluate
For shock absorption: the result and determine the type of
accumulator.
p0,t max = 0.6 to 0.9 • pm
ASPlight is aimed at users who need
(pm = average operating pressure for to determine the main accumulator
free flow) parameters in a short space of time.

For pulsation damping: 9.3.2 p0-calculator


The p0-calculator is a simple
p0,t max = 0.6 • pm conversion tool for determining the
(pm = average operating pressure) pre-charge pressure (p0) in the hydraulic
or accumulator at a specific temperature.
p0,t max = 0.8 • p1 All that is needed is the reference
(for several operating pressures) pre-charge pressure and the
current temperature of the hydraulic
During operation, the separating element accumulator measured on the gas side.
(piston, bladder, diaphragm, corrugated
bellows) must not touch the fluid-side The p0-calculator takes the real gas
connection. behaviour into account. The online
tool display is optimised for both
Since the volume of the gas increases as smartphones and desktops and is
the temperature increases, the pre-charge available online around the clock.
pressure must be determined at the
maximum operating temperature using the The p0-calculator offers reliability
recommended values. for the inspection and any required
correction of the accumulator’s
9.2.2 Limits for gas pre-charge pre-charge pressure outside of the
pressure reference temperature.
See section 9.1.
9.3.3 Accu-MOUNT
9.2.3 Temperature effect With the Accu-MOUNT, the suitable
So that the recommended pre-charge clamps, consoles and accumulator
pressures can be maintained, even at mounting sets can be identified on the
relatively high operating temperatures, basis of the accumulator designation,
the p0 charge for charging and testing cold the part number or its characteristics.
accumulators must be selected as follows: These accessories can then be added
tcharge + 273 to the request list.
p0, t charge = p0,t max • You can also find links to the
tmax + 273 corresponding product pages on our
t0 = tcharge (pre-charge temperature in °C) website and download 3D models,
brochures and other information.
To take the temperature influence into
account when sizing accumulators, The Accu-MOUNT can find the perfect
p0 at t0 must be selected as follows: mounting equipment for HYDAC
hydraulic accumulators in an instant.
tmin + 273
p0, t min = p0,t max •
tmax + 273

10. NOTE
The information in this brochure relates
to the operating conditions and fields of
application described.
For applications and/or operating
conditions not described, please contact
the relevant technical department.
Subject to technical modifications.

HYDAC Technology GmbH


Industriegebiet
66280 Sulzbach/Saar, Germany
EN 3.000.18/04.21

Tel.: +49 (0) 68 97 / 509 - 01


Fax: +49 (0) 68 97 / 509 - 464
Internet: www.hydac.com
e-mail: speichertechnik@hydac.com

18
GERMANY SWITZERLAND INDIA Technical Office St. Petersburg 27

CH

RU
DE
HYDAC INDIA PVT. LTD. Nab. Obwodnogo kanala 138

IN
HYDAC-Büro Südost HYDAC Engineering AG
Wiesestr. 189 Allmendstr. 11 A-58 TTC Industrial Area, MIDC, Mahape 190020 St. Petersburg
07551 Gera 6312 Steinhausen /Zug Navi Mumbai 400 701 Tel.: +7 812 / 495 9462
Tel.: +49 (0)365 / 73 97 5320 Tel.: +41 41 / 747 03 21 Tel.: +91 22 / 411 18-888 Fax: +7 812 / 495 9463
Fax: +49 (0)365 / 73 97 5310 Fax: +41 41 / 747 03 29 Fax: +91 22 / 2778 11 80 E-mail: petersb@hydac.com.ru
E-mail: hydac-engineering-AG@hydac.com E-mail: info@hydacindia.com Technical Office Novokuznetsk
HYDAC-Büro Nordost Internet: www.hydac.ch ul. Niewskogo 1, office 300
Zum Kiesberg 16 ITALY
HYDAC S.A. 654079 Novokuznetsk
14979 Großbeeren HYDAC S.p.A.

IT
Zona Industriale 3, Via Sceresa Tel.: +7 3843 99 1346
Tel.: +49 (0)33701 / 3389-0 Via Archimede 76 Fax: +7 3843 99 1345
Fax: +49 (0)33701 / 3389-4499 6805 Mezzovico 20864 Agrate Brianza (MB)
Tel.: +41 91 / 935 57 00 E-mail: novokuz@hydac.com.ru
Tel.: +39 039 / 64 22 11
HYDAC-Büro Hamburg Fax: +41 91 / 935 57 01 Fax: +39 039 / 68 99 682 Technical Office Ulyanovsk
Mühlenweg 131 - 139 E-mail: info.coolingsystems@hydac.ch E-mail: hydac@hydac.it ul. Efremova 29, office 418
22844 Norderstedt Internet: www.hydac.ch Internet: www.hydac.it 432042 Ulyanovsk
Tel.: +49 (0)40 / 52 60 07-0 Tel.: +7 8422 61 3453
Fax: +49 (0)40 / 52 60 07-15 CHILE JAPAN Fax: +7 8422 61 3452

CL
HYDAC Tecnologia Chile Ltda.

JP
HYDAC CO. LTD. E-mail: uljan@hydac.com.ru
HYDAC-Büro Bremen Las Araucarias 9080 -9110 / módulo F Daiwa Hatchobori Ekimae Bldg. 2F
Riedemannstr. 1 Parque Industrial Las Araucarias SWEDEN
3-25-7 Hatchobori, Chuo-ku
27572 Bremerhaven

SE
8720041 Quilicura / Santiago Tokyo 104-0032 HYDAC Fluidteknik AB
Tel.: +49 (0)471 / 700572-4200 Tel.: +56 2 / 5 84 67 54 Domnarvsgatan 29
Tel.: +81 3 / 35 37-3620
HYDAC-Büro Nord Fax: +56 2 / 5 84 67 55 Fax: +81 3 / 35 37-3622 16353 Spånga
Oldenburger Allee 41 E-mail: guillermo.viertel@hydac.com E-mail: sales@hydac.co.jp Tel.: +46 8 / 445 29 70
30659 Hannover Fax: +46 8 / 445 29 90
CHINA KOREA E-mail: hydac@hydac.se
Tel.: +49 (0)511 / 56 35 35-0
CN
HYDAC Technology (Shanghai) Ltd.

KR
Fax: +49 (0)511 / 56 35 35-56 HYDAC Korea Co. Ltd. Internet: www.hydac.se
271 Luchun Road 6th floor Daewon Bldg.
HYDAC-Büro West Shanghai Minhang 175 Bangbae Jungang-ro, Seocho-gu SINGAPORE

SG
Münchener Str. 61 Economic & Technological Development Zone Seoul 137-829 HYDAC Technology Pte Ltd.
45145 Essen Shanghai 200245 Tel.: +82 2 / 591 09 31 7 Tuas Avenue 8
Tel.: +49 (0)201 / 320 89 51-00 Tel.: +86 21 / 64 63 35 10 Fax: +82 2 / 591 09 32 Singapore 639222
Fax: +49 (0)201 / 320 89 52-22 Fax: +86 21 / 64 30 02 57 E-mail: info@hydackorea.co.kr Tel.: +65 67 41 74 58
E-mail: hydacsh@hydac.com.cn Fax: +65 67 41 04 34
HYDAC-Büro Mitte LUXEMBURG E-mail: sales@hydac.com.sg
Dieselstr. 9 CZECH REPUBLIC

LU
Friederich-Hydrotech S.à.r.l. Internet: www.hydac.com.sg
CZ

64293 Darmstadt HYDAC spol. S.R.O. 16 Route d’Esch


Tel.: +49 (0)6151 / 81 45-0 Kanadská 794 3835 Schifflange SLOVENIA
391 11 Planá nad Luznici HYDAC d.o.o.

SI
Fax: +49 (0)6151 / 81 45-22 Tel.: +352 54 52 44
Tel.: +420 381 / 20 17 11 Fax: +352 54 52 48 Tržaška Cesta 39
HYDAC-Büro Südwest Fax: +420 381 / 29 12 70 2000 Maribor
Rehgrabenstr. 3 E-mail: hydac@hydac.cz MEXICO Tel.: +386 2 / 460 15 20
66125 Saarbrücken-Dudweiler

MX
Internet: www.hydac.cz HYDAC International SA de CV Fax: +386 2 / 460 15 22
Tel.: +49 (0)6897 / 509-01 Calle Alfredo A. Nobel No. 35 E-mail: info@hydac.si
Fax: +49 (0)6897 / 509-1422 DENMARK Colonia Puente de Vigas Internet: www.hydac.si
DK

HYDAC-Büro Süd HYDAC A/S Tlalnepantla


Havretoften 5 Edo. De México, CP 54090 SLOVAKIA
Dieselstr. 30

SK
71546 Aspach 5550 Langeskov Tel.: +52 55 4777 1272 al 65 HYDAC S.R.O.
Tel.: +49 (0)7191 / 34 51-0 Tel.: +45 70 27 02 99 Fax: +52 55 5390 2334 Gorkého 4
Fax: +49 (0)7191 / 34 51-4033 Fax: +45 63 13 25 40 Internet: www.hydacmex.com 036 01 Martin
E-mail: hydac@hydac.dk Tel.: +421 43 / 413 58 93, 423 73 94,
HYDAC-Büro München MALAYSIA 422 08 75
EGYPT
MY
Am Anger 8 HYDAC Technology Snd. Bhd. Fax: +421 43 / 422 08 74
EG

82237 Wörthsee /Etterschlag Yasser Fahmy Hydraulic Eng. Lot 830, Kawasan Perindustrian Kampung Jaya, E-mail: hydac@hydac.sk
Tel.: +49 (0)8153 / 987 48-0 65-66-68 Saudi Building, Kobba Jalan Kusta, Internet: www.hydac.sk
Fax: +49 (0)8153 / 987 48-4822 P.O. Box 6550 Sawah 11813 47000 Sungai Buloh
Cairo Selangor Darul Ehsan THAILAND
HYDAC-Büro Nürnberg

TH
Tel.: +202 (2) / 4520192, 4530922 Tel.: +60 3 / 6157 0250 AEROFLUID CO. LTD.
Reichswaldstr. 52 Fax: +202 (2) / 4530638 169/4, 169/5, Moo 1
90571 Schwaig Fax: +60 3 / 6157 0252
E-mail: yasserf@yf-hydraulic.com.eg Rangsit-Nakhonnayok Rd.
Tel.: +49 (0)911 / 24 46 43-0 NETHERLANDS Patumthanee 12110
Fax: +49 (0)911 / 24 46 43-4260 SPAIN
NL

HYDAC B.V. Tel.: +66 2 / 577 2999


ES

HYDAC-Büro Berlin HYDAC Technology SL Vossenbeemd 109 Fax: +66 2 / 577 2700
IBH Ingenieurbüro und C/ Solsones 5705 CL Helmond E-mail: info@aerofluid.com
Handelsvertretung Hammer GmbH 54 – Pol. Ind. Pla de la Bruguera Tel.: +31 (0)88 0597 001
08211 Castellar del Valles Fax: +31 (0)88 0597 020 TURKEY
Kaiser-Wilhelm-Str. 17

TR
Tel.: +34 93 / 747 36 09 E-mail: info@hydac.nl HYDAC AKIŞKAN KONTROL
12247 Berlin SİSTEMLERİ SAN. VE TİC. LTD. ŞTİ.
Tel.: +49 (0)30 / 772 80 50 Fax: +34 93 / 715 95 42
E-mail: a.masoliver@hydac.es NORWAY Namik Kemal Mahallesi
Fax: +49 (0)30 / 773 80 80
NO

HYDAC AS Adile Naşit Bulvan, 174 Sok. No. 9


FINLAND Berghagan 4 34513 Esenyurt - Istanbul
ARGENTINA (Estonia) 1405 Langhus
FI

Tel.: +90 212 / 428 25 25


AR

HYDAC Technology Argentina S.R.L. HYDAC OY Tel.: +47 64 85 86 00 Fax: +90 212 / 428 70 37
Av. Belgrano 2729 Kisällintie 5 Fax: +47 64 85 86 01 E-mail: info@hydac.com.tr
(B1611DVG) Don Torcuato 01730 Vantaa E-mail: firmapost@hydac.no Internet: www.hydac.com.tr
Tigre / Buenos Aires Tel.: +358 10 773 7100
Tel.: +54 11 4727-1155/-0770/-2323 Fax: +358 10 773 7120 NEW ZEALAND TW TAIWAN
NZ

E-mail: argentina@hydac.com E-mail: hydac@hydac.fi HYDAC LTD. HYDAC Technology Ltd.


Internet: www.hydac.fi 108A Penrose Road No. 18, Shude 1st Lane, South District
AUSTRIA
Mount Wellington 1060 Taichung City 40242
(Slovenia, Croatia, Bosnia-Herzegovina,
AT

FRANCE Auckland Tel.: +886 4 / 2260 2278


Serbia and Montenegro, Macedonia)
FR

HYDAC S.à.r.l. Tel.: +64 9271 4120 Fax: +886 4 / 2260 2352
HYDAC Hydraulik Ges.m.b.H. Technopôle Forbach Sud Fax: +64 9271 4124 E-mail: sales@hydac.com.tw
Industriestr. 3 B.P. 30260 E-mail: info@hydac.co.nz Internet: www.hydac.com.tw
4066 Pasching 57604 Forbach Cedex Internet: www.hydac.co.nz
Tel.: +43 7229 / 6 18 11-0 Tel.: +33 3 87 29 26 00 UKRAINE
UA

Fax: +43 7229 / 6 18 11-35 Fax: +33 3 87 85 90 81 POLAND HYDAC Kiew


(Latvia, Lithuania)
PL

E-mail: info@hydac.at E-mail: hydac_france@hydac.com ul. Novokonstantinovskaya 9


Agence de Paris HYDAC SP.Z O.O. Korpus 13, 2 Etage
AUSTRALIA
Tel.: +33 1 60 13 97 26 ul. Reymonta 17 04080 Kiev
AU

HYDAC PTY. LTD. 43-190 Mikołow Tel.: +38 044 / 495 33 96, 495 33 97
109 Dohertys Road Agence de Lyon
Tel.: +48 32 / 226 26 55, 326 01 10 Fax: +38 044 / 495 33 98
Altona North, VIC 3025 Tel.: +33 4 78 87 83 02
Fax: +48 32 / 226 40 42 E-mail: info@hydac.com.ua
Postal address: Agence de Bordeaux E-mail: info@hydac.com.pl Internet: www.hydac.com.ua
P.O. Box 224 Tel.: +33 5 57 54 25 25 Internet: www.hydac.com.pl
Altona North, VIC 3025 Agence de Martigues USA
PORTUGAL
US

Tel.: +61 3 / 92 72 89 00 Tel.: +33 4 42 49 61 35 HYDAC Technology Corporation


PT

Fax: +61 3 / 98 360 80 70 HYDAC TECNOLOGIA, UNIPESSOAL, HYDAC Corp.


Agence Centre-Est
E-mail: info@hydac.com.au LDA. 2260 & 2280 City Line Road
Tel.: +33 3 81 63 01 65
Internet: hydac.com.au Centro Empresarial do Castêlo da Maia Bethlehem, PA 18017
Agence de Nantes
Rua Manuel Assunção falcão, 501 Tel.: +1 610 / 266 01 00
BELGIUM Tel.: +33 2 52 59 70 80
4475-041 Maia Fax: +1 610 / 266 35 40
BE

HYDAC A.S./N.V. GREAT BRITAIN Tel.: +351 223 160 364 E-mail: sales@hydacusa.com
Overhaemlaan 33
GB

HYDAC Technology Limited Fax: +351 223 160 265 Internet: www.hydac-na.com
3700 Tongeren E-mail: info@hydac.pt
De Havilland Way, Windrush Park VIETNAM
Tel.: +32 12 / 26 04 00 Internet: www.hydac.com
Witney, Oxfordshire
VN

Fax: +32 12 / 26 04 09 HYDAC International


OX29 OYG ROMANIA
Tel.: +44 1993 86 63 66 E-Town Building, Mezzanine Floor
BULGARIA
RO

HYDAC SRL Executive office, Room 7


BG

HYDAC EOOD Fax: +44 1993 86 63 65


12 Soseaua Vestului Street, Et 2 364 Cong Hoa Street, Tan Binh District
ZK Druzhba 1 E-mail: info@hydac.co.uk
100298, Ploiesti, Prahova county Ho Chi Minh City
Amsterdam 9 Internet: www.hydac.co.uk
Prahova county Tel.: +84 88 120 545 Ext. 215
1592 Sofia GREECE Tel.: +40 244 575 778 Fax: +84 88 120 546
Tel.: +359 2 / 9706070
GR

38, Amfipoleos Str. Fax: +40 244 575 779


Fax: +359 2 / 9706075 E-mail: hydac@hydac.ro SOUTH AFRICA
11855 Athens
ZA

E-mail: office@hydac.bg Internet: www.hydac.ro (Namibia, Zimbabwe)


Tel.: +30 210 341 0181 HYDAC Technology Pty Ltd.
Internet: www.hydac.bg
Fax: +30 210 341 0183 RUSSIA 165 Van der Bijl Street
BRAZIL E-mail: info@delta-p.gr
RU

HYDAC International Edenvale 1614, Johannesburg


BR

HYDAC Technologia Ltda. HONG KONG Tel.: +27 11 / 723 90 80


ul. 4, Magistralnaja 5, office 31
Estrada Fukutaro Yida, 225 Fax: +27 11 / 453 72 37
HK

HYDAC Technology (Hongkong) Ltd. 123007 Moscow


Bairro Cooperativa, 09852-060 E-mail: hydacza@hydac.com
Room 602, 6/F, Silvercord Tower 1 Tel.: +7 495 / 980 80 01
Sao Bernardo do Campo
30 Canton Road, Tsim Sha Tsui Fax: +7 495 / 980 70 20
São Paulo
Kowloon, Hong Kong E-mail: info@hydac.com.ru
Tel.: +55 11 / 43 93 66 00
Tel.: +852 23 69 35 68 Internet: www.hydac.com.ru
Fax: +55 11 / 43 93 66 17
Fax: +852 23 69 35 67
E-mail: hydac@hydac.com.br
Internet: www.hydac.com.br HUNGARY
HU

BELARUS HYDAC Hidraulika és Szüréstechnika Kft.


Ezred u. 16
BY

HYDAC Belarus
1044 Budapest
ul. Timirjazeva 65a, Biura 504-505
Tel.: +36 1 359 93 59
220035 Minsk
Fax: +36 1 239 73 02
Tel.: +375 17 375 51 32
E-mail: hydac@hydac.hu
Fax: +375 17 375 51 35
Internet: www.hydac.hu
E-Mail: info@hydac.com.by
Internet: www.hydac.com.by INDONESIA
PT HYDAC Technology Indonesia PMA
ID

CANADA
Komplek Pergudangan T8 No.27-29
CA

HYDAC Corporation
Alam Sutera - Serpong
14 Federal Road
Tangerang Selatan 15325
Welland, Ontario
Tel.: +62 21 2921 1671 / 2921 1672
L3B 3P2
Fax: +62 21 2921 1653
Tel.: +1 905 / 714 93 22
EN 3.000.18/04.21

E-mail: info@hydac.co.id
Fax: +1 905 / 714 46 64
Internet: www.hydac.co.id
E-mail: sales@hydac.ca
Internet: www.hydac.ca

19
Global Presence.

Accumulators 30.000
Local Expertise.
www.hydac.com
Fluid Filters 70.000
Process Technology 77.000
Filter Systems 79.000
Compact Hydraulics 53.000

HYDAC Headquarters
HYDAC Companies
HYDAC Sales and Service Partners
Free Sales Partners
Accessories 61.000

HYDAC TECHNOLOGY Industriegebiet


GMBH 66280 Sulzbach/Saar
Germany
Phone
Electronics 180.000

+49 6897 509-01


Fax:
+49 6897 509-454
Internet: www.hydac.com
E-mail: speichertechnik@hydac.com
EN 3.000.18/04.21
Cooling Systems 57.000