** Cyclone efficiecy checking by using Standard Effeciency Formula

Cyclone Data De Equations


H 0.80 m
Entry area dimension:
W 0.96 m Ne =1/H∗[ (Lb )/1+ (Lc )/2
S 2.26 m
]
Immersion tube dimensions: W S
De 1.50 m
Lb 5.33 m
Cylindrical part dimension: H
D 2.80 m Lb
De
Lc 3.18 m
Conical part dimension:
Dd 0.55 m
Temperture at Cyclone inlet: 800 o
C
D
Pressure at Cyclone inlet: -150 mmWg
density of material: 1500 kg/m3
density of gases(NTP): 1320 kg/m3
Gas flow rate at Cyclone inlet: 100,500 m3/h

(fill only the white cells)

Calculations Lc

Viscosity of air at temp: 0.000023 kg/m.s


Density of the gas: 331 kg/m3
Number of revolutions in the outer vortex (Ne) 9
Velocity at inlet 36.35 m/s
Gas residence time in outer vertex 2.18 sec
Cut off size of particle 12.82 microns Dd

** Raw mix particle size and Cyclone efficiency calculation (all datas are in Microns)
Minimum maximum mean (%) commulative
efficiency
Sieve Analysis sieve sieve micron of
(%)
efficiency
(microns) (microns) size retained (%)
212 300 256 3.0 1.00 2.99
150 212 181 1.0 1.00 1.00
90 150 120 15.0 0.99 14.83