1 Introduction
This document outlines the placement of different DCF products and their design flow.
The information contained in this document provides, among others, detailed design
templates for the new DCF devices that will be deployed. As such, this document will be
used as the foundation for the DCF implementation and ATP test plan will be crafted in
the next phases of the project
1.2 Scope
The scope of this document is limited to provide low level design information related to
the following DCF product as listed in the Bill of Materials (BOM) for the new
infrastructure:
✓ Rack Placement
✓ UPS, AVR & Generator placement and connection.
✓ Power distribution
✓ Air conditioner connection & placement
Confidential© 2023 Pa ge |1
IE-EPSS LLD Document
All-In-One cabinet system is equipped with Input ATS; Intelligent power distribution
module; Surge protection; Intelligent monitoring system; Cooling system;
Environment controlling system and fire suppression; access control system. It’s a
highly integrated; complete data center solution.
Confidential© 2023 Pa ge |2
IE-EPSS LLD Document
Confidential© 2023 Pa ge |3
IE-EPSS LLD Document
The cabinet system includes: IT; Network; Integrated cabinet and battery cabinet; all
the cabinet employs the 9-fold profile sheet metal as the frame to make sure the
loading capacity up to 1200kg for static loading. The cabinet with front glass door
and real metal door, all enclosure with IP5X protection.
The Cabinet with features as bellow:
✓ Front door with the glass door and rear door sheet metal double opening
✓ 19’’ standard installation with dimension 600*1000*2000mm
✓ Front with 400mm cold aisle and rear with 400mm hot aisle
✓ With vertical and horizontal cable organizer internally
Confidential© 2023 Pa ge |4
IE-EPSS LLD Document
✓ With PDU vertical mounting, each rack with 2x IESlim Intelligent PDU
✓ Front door with biometric Access control supporting biometric; Password
✓ With caster and earth wiring.
Table 2: Cabinet Specifications
Confidential© 2023 Pa ge |5
IE-EPSS LLD Document
The “M” Shape cable trough is for organizing the cable on the top of the cabinet; it split
the power and signal cable to realize the LV and HV cable isolation.
Confidential© 2023 Pa ge |6
IE-EPSS LLD Document
The containment of cabinet is equipped in each cabinet for optimize the cold and hot
air circulation, with the front and rear door isolated, all the air circulation happened
inside the cabinet to increase the heat exchange rate.
The enclosed door and the aisle seal the whole system to isolate any internal and
externally heat exchanging, all the air circulation only happened inside cabinet with
the heat insulation material.
Confidential© 2023 Pa ge |7
IE-EPSS LLD Document
Confidential© 2023 Pa ge |8
IE-EPSS LLD Document
a) Dual bus structure support power method backup for the mission critical IT
load
b) Dual UPS connected with dual bus, each UPS offers the whole power
backup
The Integrated Power Cabinet is used to accommodate the UPS; Cooling; DCIM
monitoring and power distribution module, which is the chief management of the
whole data center power system. In the same time to avoid the rack space
occupation of the IT cabinet. Inside it contains:
Confidential© 2023 Pa ge |9
IE-EPSS LLD Document
The Rack Mounted Power Distribution module is inside the integrated cabinet for the
main power input and output. The module includes the main power input; UPS
in/output; cooling input; PDU and surge protection breakers, with the RS385/SNMP
port for easy communication.
Confidential© 2023 P a g e | 10
IE-EPSS LLD Document
Confidential© 2023 P a g e | 11
IE-EPSS LLD Document
Confidential© 2023 P a g e | 12
IE-EPSS LLD Document
IE proposes Eaton 93E 20kVA UPS with Internal batteries 64x9Ah. 93E delivers up to
98% efficiency.
Confidential© 2023 P a g e | 13
IE-EPSS LLD Document
IE provides tripplite On-line double-conversion UPS pure sine wave AC output to server
and network equipment for remote site active devices deployed on each rack.
ENERGY STAR-certified to save electricity, lower costs, and protect the environment
Confidential© 2023 P a g e | 14
IE-EPSS LLD Document
The IESlim Series Intelligent PDU includes the management and metered type. With
all output outlet optional. The PDU is equipped with the digital sensor port for
environment sensor connection in each cabinet, serving as a data transferring
station. The intelligent PDU utilize the SNMP-Link platform for management.
Table 5: Intelligent PDU Electrical Specification:
3.3 Generator
The generator power system for the data center is going to be used as backup power
source and the design is done as such the capacity of the generator will be able to
support the whole data center systems and future requirement. If the utility power is
interrupted the generator power source in the other side will start up automatically
and supply power for the whole data center systems within few minutes. IE-Networks
will provide 80kva Generator.
Features:
Confidential© 2023 P a g e | 15
IE-EPSS LLD Document
Confidential© 2023 P a g e | 16
IE-EPSS LLD Document
Confidential© 2023 P a g e | 17
IE-EPSS LLD Document
The bellow design is for power distribution for the data center.
Confidential© 2023 P a g e | 18
IE-EPSS LLD Document
Confidential© 2023 P a g e | 19
IE-EPSS LLD Document
Confidential© 2023 P a g e | 20
IE-EPSS LLD Document
Confidential© 2023 P a g e | 21
IE-EPSS LLD Document
Confidential© 2023 P a g e | 22
IE-EPSS LLD Document
4 Cooling System
Confidential© 2023 P a g e | 23
IE-EPSS LLD Document
Confidential© 2023 P a g e | 24
IE-EPSS LLD Document
Confidential© 2023 P a g e | 25
IE-EPSS LLD Document
Reheat-kW 6.0
Outdoor Unit IEFS38AN
Height-mm 695
Depth-mm 990
Width-mm 1407
Leg Height-mm 450
Weight-kg 120
Power Input1) 380V/50-60Hz /3Ph
Key Features
✓ Designed for rack mount, row mount, wall mount or top mount to be
seamlessly integrated into server racks. Customizable to match closed aisle
or open aisle modular data center solution.
✓ Standard monitoring port to be integrated into higher level DCIM system
easily.
✓ Front door and structure customizable to be built into MDC to keep uniform
design style.
✓ Reliability
✓ Developed by professional precision cooling team following proven R&D process
and industry standards.
✓ Designed with recognized components and thorough testing to enhance
reliability level.
✓ Full protection and alarm control system for quick diagnose and reactivate the
unit.
✓ Green & Efficient
✓ Cooling capacity and air flow automatically modulated to match the dynamic
IT output.
✓ Dedicated cooling close to IT heating source saves more than 30% energy
comparing to traditional room cooling solution.
✓ Serviceability
✓ Unit level and components level modularity supports quick replacement and
reduce MTTR.
✓ Swappable fans allow system to remain operational if a replacement is required.
Easy electric box service operation with the slide-out design.
Confidential© 2023 P a g e | 26
IE-EPSS LLD Document
Confidential© 2023 P a g e | 27
IE-EPSS LLD Document
5 DCIM
Confidential© 2023 P a g e | 28
IE-EPSS LLD Document
and CANBUS are all connectable. Flexible in expansion. The remote access
are also available via the network in client.
Confidential© 2023 P a g e | 29
IE-EPSS LLD Document
Confidential© 2023 P a g e | 30
IE-EPSS LLD Document
Key Features:
Confidential© 2023 P a g e | 31
IE-EPSS LLD Document
6 Firefighting System
Confidential© 2023 P a g e | 32
IE-EPSS LLD Document
SI-IE-EPSS-ITF-BOQ
No Uo Qt
Item Type Feature
. M y.
Confidential© 2023 P a g e | 33
IE-EPSS LLD Document
Confidential© 2023 P a g e | 34
IE-EPSS LLD Document
Confidential© 2023 P a g e | 35
IE-EPSS LLD Document
Sensing Input:
Voltage: 100 VAC to 130 VAC 1 phase or 190
VAC to 264 VAC 1 phase1
Frequency: 50 Hz to 60 Hz nominal Power
Input:
Voltage: 100 VAC to 264 VAC 1 phase only
Frequency: 50 Hz to 60 Hz nominal
UC1224G Pcs 1
Power Output
Voltage: maximum 82 VDC at 200 VAC input
Current :continuous 4 A2 ,transient 7.5 A for
10 seconds
Resistance: 15 Ω minimum (10 Ω minimum
when power input less than 175 VAC)
Regulation:+/- 1.0% RMS3
Accessories
1 Power requirments
Confidential© 2023 P a g e | 36
IE-EPSS LLD Document
Name Name
Title Title
Company Company
Signature Signature
Date Date
Name Name
Title Title
Company Company
Signature Signature
Date Date
Name Name
Title Title
Company Company
Signature Signature
Date Date
Confidential© 2023 P a g e | 37