You are on page 1of 6

METHOD STATEMENT

Assessment of Glass Breakage pattern of


Laminated Glass

SFMC - Riyadh
Advance Manufacturing for Metal & Glass

MS No. VJ107/02/11/21/MS00

SFMC Riyadh
MS Date: 02/11/2021 11:48 AM
File: VJ107
File Name: VJ107-SFMC Laminated Glass Breakage Test MS

PO BOX 26385, DUBAI UAET +971 (0)4 333 2692 admin@bell-wright.com www.bell-wright.com

DUBAI ABU DHABI DOHA RIYADH

Copyright© This document shall not be reproduced except in full without written approval of Thomas Bell-Wright International Consultants
Accreditation
ISO 17025 General requirements for the competence of testing and
calibrating laboratories by
1. United Kingdom Accreditation Service (UKAS) – 4439
www.ukas.com

2. GCC Accreditation Center – ATL-0017


www.gac.org.sa

3. Emirates International Accreditation Centre – 188-LB-TEST


www.eiac.gov.ae

Memberships
Member of Centre for Window and Cladding Technology
www.cwct.co.uk

Member of Council on Tall Buildings and Urban Habitat


www.ctbuh.org

Member of the International Code Council


www.iccsafe.org

The work which is a subject of this document falls wholly or partly under the
accreditation checked below

ISO 17025 UKAS 


ISO 17025 GAC 
ISO 17025 EIAC 

It is a non-accredited test 

SFMC – RIYADH Page 2 of 6


Table of Contents
SFMC - Riyadh ................................................................................................................................................. 1
1. GENERAL PARAMETERS .......................................................................................................................... 4
2. WITNESSES .............................................................................................................................................. 5
3. TEST SPECIMEN ....................................................................................................................................... 5
4. TEST SUMMARY ...................................................................................................................................... 5
5. METHOD STATEMENT ............................................................................................................................. 5
5.1. Scope of Work: ................................................................................................................................ 5
5.2. Inspection Procedure: ..................................................................................................................... 5
5.3. Proposed Number of Test Samples:................................................................................................ 5
5.4. Required instruments for inspection: ............................................................................................. 5
5.5. Assessment of fragmentation: ........................................................................................................ 5
6. CONCLUSION ........................................................................................................................................... 5
7. Drawing ................................................................................................................................................... 5
8. Photograph ............................................................................................................................................. 6

SFMC – RIYADH Page 3 of 6


Visual Assessment of Glass Breakage
Pattern
1. GENERAL PARAMETERS
This is the Method of statement for the Glass Breakage Pattern carried out by this firm on
façade for the project. The formal testing shall be carried out under the supervision of the Testing
Engineers of TBWIC and witnessed by representatives from the Contractors.
TEST SEQUENCE
Test 1 Visual Assessment of Glass Breakage Ad-Hoc Test,
Pattern

RELEVANT INFORMATION
Type Unitized panel laminated glass
Materials
Glass Type laminated panel
Glass Thickness 9.52 mm Laminated glass (4 + 1.52 + 4) mm
Specimen Size 1. 1466mm X 1785mm (4mm+1.52PVB+4mm) Laminated Heat Strengthened glass –
01 pcs.
Unitech glass 2. 1466mm X 1785mm (4mm+1.52PVB+4mm) Laminated Tempered glass – 01 pcs.
factory 3. 1316mm X 1785mm (4mm+1.52PVB+4mm) Laminated Heat Strengthened glass –
01 pcs.
4. 1316mm X 1785mm (4mm+1.52PVB+4mm) Laminated Tempered glass – 01 pcs.
From the above laminated types single face will be broken

Specimen Size At the same time, Contractor shall deglaze the glasses chosen by the client at site which been
installed.
Dismantle Deglazed IGU shall be kept separately and only on laminated glass on single face
from site and fragmentation test will be performed
deglaze panel
1. 1466mm X 1785mm (4mm+1.52PVB+4mm) Laminated Tempered glass – 02 pcs.
2. 1316mm X 1785mm (4mm+1.52PVB+4mm) Laminated Tempered glass – 02 pcs.
From the above laminated panel- single face will be broken
So, 4 Pcs from Factory + 4 Pcs from Site – to be tested (breakage test will be
performed on single face of lamination)

Purpose of this test is to compare tested breakage laminated glass pattern with
installed at site broken laminated glass pattern
Flat/Curve Flat

Client Will be indicated in the final report


Main Contractor Will be indicated in the final report
Alum. Contractor Will be indicated in the final report
Consultant Will be indicated in the final report

SFMC - RIYADH Page 4 of 6


2. WITNESSES
NAME COMPANY TELEPHONE
Will be indicated in the final report

3. TEST SPECIMEN
The specimen to be tested in different locations is to be selected by Client/Consultant.

4. TEST SUMMARY
A brief report for the conducted test will be attached with the final report.

5. METHOD STATEMENT
5.1. Scope of Work:
Laminated glass will be broken intentionally and compared with the pattern of broken
glass in site.
5.2. Inspection Procedure:
1) The Glass units to be tested shall be laid on flat table without any mechanical
constraint.
2) Contractor is requested to prepare “flat” clothed table of approximate size 1.8mtr X
1.8mtr.
3) To carry out this test, the glass units will be impacted by Steel hammer/Star
Screwdriver on the edge until breakage occurs.
5.3. Proposed Number of Test Samples:
As agreed by all parties and report of each glass shall be recorded.
5.4. Required instruments for inspection:
Steel Hammer, Star Screwdriver or pointed steel tool, Adhesive tape (Masking tape).
Note: All these instruments including the wooden supports or a table shall be made
available at site by the Project team.
5.5. Assessment of fragmentation:
Once the laminated panel has been broken intentionally, this will be compared with the
pattern of broken glass in site.

6. CONCLUSION
Will be attached in Final Report

7. Drawing
Will be attached in Final Report

SFMC – RIYADH Page 5 of 6


8 Photograph
Will be attached in Final Report

9 Please note that during breakage test of lamination glass, If Lite 1 glass break
while hitting/breaking Lite 2 (tested glass), in that case TBWIC will not be
responsible.

Thomas Bell-Wright International


Consultants

Test Conducted & Report prepared by: Reviewed & Authorized by:

Nakash Shaikh Reji Bhami


Site Testing Engineer Site Testing Manager

---End of Method Statement---

SFMC - RIYADH Page 6 of 6