Gas Chromatograph

GC-1100

Introduction

Systronics GC1100 Gas Chromatograph system has been designed using PLC control system. System
consists of precision EPC flow control, sampler, separation system, column oven, detectors, and temperature
control, detector and chromatography workstation. Controls and parameter setting establishes by the 4”
Colour Touch Screen display with real-time display of all parameters setting value and actual value.

Product Features

 Auto diagnostics and self-check on power on.


 Choice of various Detectors.
 PLC based system.
 4” HMI Colour Touch Screen Display

Product Characteristics

 Provision for Packed and Capillary Column Injector Ports.


 Choice of Inlet systems – Packed, Capillary, Methanizer, PTV, GSV etc.
 Auto diagnostics and self-check on power on.
 Electronic safety cut off with alarm (audio-visual) for all heated zones are also user settable.
 Auto cooling with forced air convection through the Micro controller with user definable set point.
 Isothermal as well as programmable Mode with 3 steps and 10 method files storage.
 Advanced built-in data acquisition system, supporting real time instrument status monitoring,
detection signal acquisition.
 Column Compartment/oven with superior thermal performance, multistage (8 ramps)
programmed temperature control function and 10 method files.
 Column oven accommodates up to 3 chromatographic columns, and supports multi oven
ramps to quick heat-up and rapid cool-down with automated back-door opening.
 Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.).
Technical Specifications GC1100
Column Oven :
Inner Volume : 28 lit Auto Cooling Option : Forced Air Cooling
Temp. Range : Upto 450° C Heating Rate : 50°C to 450°C in 8 Min.
Cryogenic Option : Option Available Cooling Rate : 450°C to 70°C in 8 Min.
Temp. Read out : 4” Colour HMI Display Programming Steps : 3 Ramps
Temp. Accuracy : ±0.1°C Method Files : 10
Temp. Stability : ±0.1% Temp. Setting : 1°C
Overheat Protection : Dual Electronics + S/W
Injectors :
Choice of Injector : Packed, Capillary, PTV Temp. Read Out : 4” Colour HMI Display
Number of Injector : Methanizer, GSV upto 3 Temp. Accuracy : ± 1%
Temp. Range : Ambient to 450°C Temp. Stability : ± 1%
Overheat Protection : Dual Electronics + S/W
Detectors :
Choice of Detector : FID / TCD / Dual FID Temp. Read Out : 4” Colour HMI Display
Number of Detector : Any Three Temp. Accuracy : ± 1%
Temp. Range : Ambient to 450°C Temp. Stability : ± 1%
Overheat Protection : Dual Electronics + S/W
Pneumatics :
Pressure Control : 3 Stage Control : From HMI Input
Flow Control : EPC Automatic
FID Detector :
Cell Type : SS with flame Drift : <5μV per minute
Input Impedance : 1013 Ω Zero Balance : One Potentiometers
Sensitivity : >1ppm of CH4 Attenuator : NA
Linear Range : 1 x 107 To Integrator : 0 – 1.5V DC
Noise : <1% per day (<2μV) Detector Voltage : 14V DC
Amplifier Gain : X1 & X100 Operating Temp. : 50°C to 450°C
TCD Detector :
TCD Block : SS 316 Grade Zero Balance : One Potentiometers
Filament : Tungsten Rhenium Attenuator : Low And High
Current Range : 0 to 350mA (Adjustable) Linear Range : >106
Current Monitoring : 4” Colour Touch HMI Polarity : +Ve / -Ve Switch
Bridge Current : Constant Current Mode Output : NA
Operating Temps. : Ambient to 450°C To Integrator : 0 – 1.5V DC
Response time : < 0.5 Seconds Dimension : 21” H x 25” W x 24” D
Sensitivity : 100ppm of O2 in N2 Weight : 65Kgs