Professional Documents
Culture Documents
0004
1 2 3 4 5 6 7 8 9 10
GENRAL NOTES:
57400
100 7400 2600 8200 8200 8200 8200 6700 1500 6400 700
THIS DRAWING IS NOT TO BE SCALED.
FIGURED DIMENSIONS TO BE USED AT ALL TIMES.
7600 2400 420 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 2130 900 1650 900 2200 600
CONTRACTOR IS RESPONSIBLE FOR CORRECT SETTING OUT OF
200 7200 200 2400 200 8000 200 8000 200 8000 200 8000 200 8000 200 2295 200 3710 200 THE BUILDING. ALL EXTERNAL AND INTERNAL WALLS WITH
PARTICULAR REFERENCE TO BUILDINGLINES, BOUNDARIES, ETC.
200
200
300
300
H H
600
600
CONTRACTOR TO VERIFY ALL LEVELS, HEIGHTS AND DIMENSIONS
W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02
ON SITE AND TO CHECK SAME AGAINST THE DRAWING BEFORE
PUTTING ANY WORKIN HAND.
2555
2600
ALL CONTRACTORS TO CHECK DETAILS SHOWN ON THIS
2500
FILING
3500
3500
3580
FINANCE / DRAWINGS FOR COMPLIANCE WITH STANDARDS OF GOOD
W04
ROOM
4300
BUILDING PRACTICE WITH PARTICULAR REFERENCE TO SPECIAL
FEES OFFICE
3900
REQUIREMENTS NECESSITATED BY LOCAL AND OR ON SITE
CONDITIONS AND REPORT ANY COMMENT TO THE ARCHITECT.
900
W02
900
D01
CLASSROOM 15 CLASSROOM 18 CLASSROOM 19 CLASSROOM 20 CLASSROOM 21 ANY ERROR DISCREPANCIES OR OMMISSIONS TO BE REPORTED TO
6800
6800
1400
200
THE ARCHITECT IMMEDIATELY.
1045
600
D01
7000
7000
7000
7000
7000
FINAL DIMENSIONS TO BE TAKEN ON SITE BEFORE ORDERING,
SUPPLYING AND FIXING PROPRIETARY ON DETAILED FITTINGS.
900
900
3620
CONTRACTORS ARE TO LOCATE AND IDENTIFY EXISTING SERVICES
3470
3900
900
1000
5000
220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 1200 2310
4200
4200
W05
D02 D02 D02 D02 D02
900
W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02
G D02
DN VICE
G ARE SHOWN ON DRAWINGS TO ALL EXTERNAL WALLS, AT EACH
1300
1300
1900
240 1255 200 800 200
16200
16200
200 900
D01 OFFICE
1600
200
BRICK WALLS AND EVERY 2ND COURSE ABOVE WINDOWS, DOORS
F F
3400
600
200
600
AND ALL OTHER OPENINGS.
200
D01
900
W02 W02
W05
4200
4200
PRINCIPAL ON HAND.
5000
5000
4800
4800
4600
CW02
OFFICE QUALITY OF ALL MATERIALS AND WORKMANSHIP TO COMPLY WITH
1000
1000
7200 2400 200 39300 200 1300 THE RELEVANT S.A.B.S. AND B.S.S. SPECIFICATIONS.
900
900
W02 W02
400 1525 1575 1000 900 800
D03
600
E E
1000
1045
200
200 1300 3700 D01
COVERED WALKWAY
900
900
W02 W02
COVERED FOYER-
COVERED WALKWAY
WATER TANKS
1000
1905
200
ABOVE
500
2500
5800
PROJECT
6600
PROPOSED SCHOOL
35000
35000
18200
17800
8600
2400
7600
2400
7600
7400
7400
1400
900
W02 LOCKERS
FILING LUBUMBASHI - DRC
500
ROOM
200
1905
500
D02
900
600 3100
1600
W02
200 3500
800
DRAWING
1000
200
600
D03
900
W02 W02
8000
8000
CLASSROOM 17
1000
1000
4600
5000
5000
4200
4200
CW02
W05
900
900
W02 W02
7200
2300
C C
600
600
3555
MEETING ROOM /
200
BOARDROOM
200
COVERED WALKWAY
1900
1300
1300
1900
500
B B
13700
13700
D02
1400
D02
W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02
900
4200
4200
W02 D02 D02 D02 D02
W05
220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680 220 900 1000 900 1000 900 1000 1400 680
1045
1100
3620
9100
900
900
W02 W02
7000
7000
7000
7000
7000
8000
8000
1000
1400
CLASSROOM 16 CLASSROOM 14 CLASSROOM 13 CLASSROOM 12 CLASSROOM 11 CLASSROOM 10
6800
6800
DN
900
W02
3900
4100
3580
2500
W04
7200 8000 8000 8000 8000 8000 6200
2400
W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02 W02
A A
600
600
300
300
200
200
200 7200 200 2400 200 8000 200 8000 200 8000 200 8000 200 8000 200 6200 200 600
10420 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 1600 900 1000 900 1000 900 1000 900 2560 900 1000 900 1000 900 520 600
100 7400 2600 8200 8200 8200 8200 6700 1500 6400 700
57400
SCALE DATE DRAWN CHECKED
1 : 100 06-MAY-2023 Author Checker
1 2 3 4 5 6 7 8 9 10 PROJECT NUMBER
DRAWING NUMBER
0004
REVISION
0003