You are on page 1of 1

INVEMID 220 - MW 37C, MW 38C

PRODUCT CONSTRUCTION
Copper

Polyamide-imide
Modified
polyesterimide
GENERAL INFORMATION
MAIN USES REFERENCES

• Alternators, ignition coils Round Square and


• Electric toolst MW-37C Rectangular
• Motors for home appliances MW-38C
• Motors for vehicle wind wipers
• Hermetic Motors
• Motors and high tension transformers
• Ballasts for fluorescent lamps

PROPERTIES AVAILABILITY

• Resistant to high temperatures Round Square and


• Optimal mechanical resistance 04 to 34 AWG Rectangular
• Resistant to cooling fluids and chlorinated oils See graph

TYPICAL PROPERTIES
(This data is typical of 18 AWG copper, heavy build insulation only. It is not intended to be creating specification limits)

THERMAL PROPERTIES ELECTRICAL PROPERTIES

Thermal Endurance (20000hr) Dielectric Breakdown


Specification: 220°C Specification: min - 5700 V
Typical Values: >220°C Typical Values: 13000 V

Thermoplastic Flow Dielectric Strenght at 220°C


Specification: 325°C Specification: min - 4275 V
Typical Values: 400°C Typical Values: 9000 V

Heat Shock High Voltage Continuity


Specification: 20% - 3xØ - ½ hr at 240°C - no cracks Specification: 5 faults/100 feet - 1500 V
Typical Values: No cracks Typical Values: 0 faults/100 feet - 2500 V

CHEMICAL PROPERTIES Pinhole (JIS 3003)


Specification: 2% salt water 1 minute at 12 V
Retained Dielectric after 72 hrs Typical Values: 0 faults
exposure to R-22
Specification: min 5700 V
Typical Values: 11500 V
MECHANICAL PROPERTIES
R-22 Extractable
Specification: max 0.25% Mandrel flexibility after elongation
Typical Values: 0.17% Specification: 20% - 3xØ no cracks
Typical Values: 20% - 2xØ no cracks
Resistance to solvents
Specification: Xylene and 50/50 Unilateral Scrape (Avg. of 3 sides)
Xylene/Butyl Cellesolve Specification: min - 1150 g
Typical Values: Pass Typical Values: 2100 g

Transformer Oil resistance (IEC-60851-4)


Specification: Dielectric strenght after 1000 hr at 150°C
Min Average - 5700 V
Typical Values: 12000

You might also like