A-Frame

Alternators

A Frame
Standby Power
50 Hz 33-715 kVA 1500 rpm
60 Hz 30-600 ekW 1800 rpm
Prime Power
50 Hz 30-650 kVA 1500 rpm
Image shown might not reflect actual configuration 60 Hz 26-545 ekW 1800 rpm

DETAILS
Main components Construction
• Enclosure - ODP - Open Drip Proof
Housing • Cooling System - IC 01 as per IEC60034-6
• Rigid frame, rugged welded steel fabrication • Degree of protection - IP 21 as per IEC60034-5

Insulation
• Class H Certificates and testing
Shaft • Generators are designed in compliance with:
• S ingle bearing generator: cylindrical shaft with key • IEC EN 60034 – 1
• IEC EN 60034-22
• Made in carbon steel and obtained by lamination.
• BS4999-5000
• Shaft material for diameters of 230 mm and above is • NEMA MG1-22
40Cr steel (GB/T 3077-1999). • VDE 0530
• All rotors are dynamically balanced at factory before • GB755-2008
delivery • CCS GB12975
• GB/T7060
Automatic Voltage Regulator • Operating conditions
• GRTA-2D (Analog) / GRT7-TH4E (Analog) • THD (Total Harmonic Distortion) less than 3%
• TIF<50 & THF<2%
• 2/3 pitch winding to eliminate third harmonic content
Main Terminal Box
• Top mounted
• Made of Q235-A(GB/T 700-2006)) Vibration
• V
 ibration level is in accordance with GB/T6075 equals
to ISO 10186.
Fan • Follows GB10068 (equal to IEC60034-14).
• Fan for alternators, 26.4<44 ekW is made of plastic
• Fan for alternators >44 ekW is made of aluminum alloy
ZL104 (GBT 1173).

LEHE1126-01

A-Frame
Alternators

Technical Data
Stator/Rotor Core Operational Considerations
• L aminated and enamel-insulated on both sides to • Self-exicted brushless excitation system (Standard)
minimise eddy-current losses • Permanent Magnet Generator (Optional)
• Coastal Insulation Protection (Optional)
• Anti-Condensation Heater
Rotor • IP23 Protection (Optional)
• Salient pole type. • Three layers of anti-corrosive treatement to the rotor and
• Copper flat wire construction. stator.
• H class insulated with enamel coating.
• Winding retaining by pass-through bars of high quality
steel Technical Parmeters
• Rotating rectifier: Graetz diode bridge with 6 diodes with • Rated voltage: 220-480V, 3-Phase
surge suppressors • External voltage adjustment: +/- 10%
• Rotors are dynamically balanced with a half key applied • Steady state voltage regulation factor: ≤1%
to the shaft extension in accordance with • Overspeed endurance: 2250 rpm for 2 minutes
• IEC 60034-14 to vibration grade norm A. • Overload endurance: 110% for 1 hour,150% for 2 minutes
• Rotor is balanced by adding weight on the fan and the
balance ring.
• Special vibration level constructions are available. Accreditations & Certifications
• ISO9001:2015

Bearing
• A
 Frame generators can have one of the two bearings
types listed below:
• Sealed bearing with approximate grease life of 20,000
running hours or 3 years.
• Re-greasable bearing with approximate life of 50,000
running hours (requires periodic lubrication)..

www.cat.com/electricpower
©2020 Caterpillar
All rights reserved.
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.
CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow,”
the “Power Edge” and Cat “Modern Hex” trade dress as well as corporate and product identity
LEHE1126-01
(01/21) used herein, are rademarks of Caterpillar and may not be used without permission.