ER300P-PRIDE
Electronic Trivector Meter
(Panel Mounting)
Class 1.0 / Class 0.5S / Class 0.2S
Table of contents
1 General
2 Design
2.2 Hardware
2.2.1 Compact
2.2.2 Efficient
2.2.3 Ruggedness and Safety
2.2.4 Features
2.2.5 Data Safety
2.3 Software
2.3.1 Energy Accumulators
2.3.2 Energy Accumulation Methods
2.3.3 Maximum Demand (MD) Registers
2.3.3.1 Method of MD calculation
2.3.4 Time of the day (TOD) metering
2.3.5 Reset
2.3.5.1 Reset modes
2.3.5.2 Reset data
2.3.6 Load Survey recorders
2.3.7 Instantaneous parameters
2.3.8 Tamper/Failure recording
2.3.8.1 Tamper types
2.3.8.2 Tamper record
2.3.8.3 Tamper Features
2.3.8.4 Power fail records
2.3.9 Other programmable features
1
2.3.9.1 With two level protection
2.3.9.1.1 Uni/Bi-directional configuration
2.3.9.1.2 VAh calculation methods
2.3.9.1.3 External CT/PT ratios
2.3.9.1.4 MD settings
2.3.9.1.5 TOD settings
2.3.9.1.6 Reset settings
2.3.9.1.7 Load survey settings
2.3.9.2 With one level protection
2.3.9.2.1 RTC setting
2.3.9.2.2 Display details
2.3.9.3 Factory configurable
2.3.9.3.1 Unit code setting
2.3.10 Communication
2.3.10.1 Communication Interface
2.3.10.2 Programming mode records
2.3.10.3 Data collection
2.3.10.3.1 Specific data collection
2.3.10.3.2 All data collection
2.3.11 Accuracy Tests
2.3.11.1 Pulse counting method
2.3.11.2 High resolution method
2.3.11.3 Using MRI
2.3.12 Internal Battery Option
3. Installation
3.1 Incoming Inspection
3.2 Re-packing
3.3 Optimum field conditions
3.4 Storage
3.5 Mounting
3.6 Extra precautions
3.7 Connections
4. APPENDIX A
Fig. 1. Parts/Dimensions -
Fig. 2. Parts/Dimensions – Rear View
Fig. 3. 3Ph 4W connection diagram – with CT
Fig. 4. 3Ph 4W connection diagram – with CT & PT
2
Fig. 5. 3Ph 3W connection diagram – with CT & PT
5. APPENDIX B - Technical specifications.
6. APPENDIX C - Display parameters
1. GENERAL
• Optional features
Communication – RS 232
RS 485
Internal battery.
4
2. DESIGN
2.2 HARDWARE
2.2.1. Compact
5
2.2.2. Efficient
2.2.4. Features
6
panel of the meter, to operate the battery to enable
data collection, viewing display and manual
resetting during power failure. This is an optional
feature.
7
2.3. SOFTWARE
8
Note:
9
• Reset MD Registers with tariffs
These are the tariffwise MDs for the present billing period
i.e. from the time of latest reset. If a reset is performed, these
values are pushed to backups and these registers get
cleared.
10
For MD1 (Sliding window method)-
Demand - 09:00 to 09:30 block = (20*15+30*15)/30 = 25kVA
Demand - 09:15 to 09:45 block = (30*15+30*15)/30 = 30kVA
Demand - 09:30 to 10:00 block = (30*15+20*15)/30 = 25kVA
MD1 at the end of 10:00 = 30 kVA
11
Note:
Reset time and the TOD settings should be a multiple of the
integration periods of MD registers.
2.3.5 RESET
1. Manual Reset
The meter can be reset manually by operating a
push button on the front panel.
Lockout days i.e. no. of days before which another
manual reset can be performed, is programmable
between 0 to 99 days.
2. Auto Monthly :
The meter can be reset automatically on a preset
date and time.
The date could be a positive absolute date (1 to 28)
i.e. the meter resets on the date set at the preset
time.
Or
The date could be set as a negative no. (0 to –27)
i.e. the no. of days from the end of the month.
Eg. If the date is programmed to -2, then reset will
occur automatically on 29th Jan, 26th Feb. (if non
th th
leap year), 29 March, 28 April and so on at the
preset time.
12
2.3.5.2 RESET DATA
13
Three segments on LCD indicate the presence/absence of
phase voltages and currents.
If voltage is absent in a phase, the corresponding phase
segment is OFF. If only voltage is present in that phase then
it is ON. If both voltage and current are present in that phase
then it blinks at a fixed rate.
5. Current Reversal
Whenever a phase current is reversed, the meter records a
current reversal for that phase and gives an indication of the
present status of current reversal on the display as ‘1’.
15
2.3.8.3 TAMPER FEATURES
16
2.3.9.1 WITH TWO LEVEL PROTECTION
• Uni-directional configuration
The meter records forward energies in forward registers.
The reverse energies are added to the forward registers and
are also recorded separately in reverse registers. i.e.
Forward register = Forward energy + Reverse energy
Reverse register = Reverse energy
• Bi-directional configuration
The meter records import energies in forward registers and
export energies in reverse registers. i.e.
Forward register = (Forward energy + Reverse energy)
Updated if algebraic Sum of energy is +ve
Reverse register =(Forward energy + Reverse energy)
Updated if algebraic Sum of energy is -ve
CT * PT Display format
< 10 xxxxxx.xx K
< 100 xxxxxxx.x K
< 1000 xxxxxxxx K
< 10000 xxxxxx.xx K x 103
< 100000 xxxxxxx.x K x 103
<1000000 xxxxxxxx K x 103
2.3.9.1.4 MD SETTINGS
18
The real time of the meter can be set.
Mode 1:
- Display parameters selectable upto 55 nos. in any
sequence required.
- Auto and manual scroll facility available.
Mode 2:
- Display parameters selectable upto 255 nos. in any
sequence required.
- Manual scroll facility only
Mode 3:
- Display parameters fixed- High resolution cumulative
forward & reverse Wh/VArh.
- Manual scroll facility only
• Mode Switching – Switching between modes is
possible by simultaneously pressing the UP and DOWN
keys.
If no key is pressed for 5mins. then meter automatically
switches back to MODE 1 auto display.
19
• Manual scrolling – Manual scrolling within a
display mode is possible by using UP or DOWN
keys.
2.3.10 COMMUNICATION
KWh & kVArh pulse output LEDs are provided on the front
panel.
Pulses/kWh (or kVArh) Voltage/Current
2,500 / (external CT*PT) 3ph 4W 415V(L-L) / 5A
12,500 / (external CT*PT) 3ph 4W 415V(L-L) / 1A
10,000 / (external CT*PT) 3ph 3W/4W110V(L-L) /5A
50,000 / (external CT*PT) 3ph 3W/4W110V(L-L) /1A
21
In absence of power, a key on the front panel enables to
operate the meter on a NiCd battery for - viewing the display,
collecting data and manual resetting of the meter.
22
3. INSTALLATION
3.2 Re-packing
For the reliability and better life of the product the unit has to
be operated at moderate temperatures and humidity. The
meter is designed to work from -5 to 60 deg C and
humidity of 95% RH non condensing.
3.4 Storage
3.5 Mounting
23
3.7 Connection
24
APPENDIX A
Fig. 1
25
26
Fig. 2
27
28
APPENDIX B
Accuracy IEC 61036/IS 13779/CBIP-88
Class 1.0
IEC 60687/CBIP-88/IS14697
Class 0.5S/0.2S
Voltage(Vn) 3Ph 4W-415V AC
3Ph 3W-110V AC
3Ph 4W-110V AC
(Range -40% to +20% for all)
Current (In) 5A (to 200%)
1A (to 200%)
Starting current 0.1% In (Class 0.5S/0.2S)
0.2% In (Class 1.0 )
Power Factor 4 quadrant operation
Frequency 50Hz +/-5%
Load characteristics in potential circuit <8VA
in current circuit <0.5VA
Electromagnetic compatibility IEC 61036/IS13779/CBIP-88
(Class 1.0)
IEC 60687/IS14697/CBIP-88
(Class 0.5S/0.2S)
Case material Plastic molded with transparent
Cover.
Insulation properties HV & Insulation resistance
IEC 61036/IS13779/CBIP-88
(Class 1.0)
IEC 60687/IS14697/CBIP-88
(Class 0.5S/0.2S)
Temperature -50c to 600 c for operation
-200c to 700c for storage
Humidity 95% RH non condensing
Dimension 247L x 180W x 108H
Weight Approx. 1.7 Kgs
29
APPENDIX C – DISPLAY PARAMETERS
NOTE: THE ACTUAL DISPLAY ON LCD IS AS INDICATED IN QUOTES " "
(No. of Parameters on Display shall be customer specification)
Instantaneous Values
1-3) R,Y,B Phase Voltage "Ta xxx.x "
"Up V"
(p=1,2,3 phase; a=0,1,..7 active tariff no.)
30
"Ta xx.xxxxxx kVAh"
"C_ "
21) Cumulative Reverse kWh " -<- "
(<- indicates Reverse) "Ta xx.xxxxxx "
"C_ kWh"
31
49-56)Cum. Forward kVArh lag " ->+ lag "
Tariff 0 to 7 "Ta xxxxxx.xx kVArh"
"Ct "
57-64)Cum. Reverse kVArh lag " -<- lag "
Tariff 0 to 7 "Ta xxxxxx.xx kVArh"
"Ct "
65-72)Cum. Forward kVArh lead " ->+ lead "
Tariff 0 to 7 "Ta xxxxxx.xx kVArh"
"Ct "
73-80)Cum. Reverse kVArh lead " -<- lead "
Tariff 0 to 7 "Ta xxxxxx.xx kVArh"
"Ct "
81-88)Cum. Forward kVAh " ->+ "
Tariff 0 to 7 "Ta xxxxxx.xx kVAh"
"Ct "
89-96)Cum. Reverse kVAh " -<- "
Tariff 0 to 7 "Ta xxxxxx.xx kVAh "
"Ct "
32
m = 1,2,3 MD;t=0,1..7 tar.no.)
33
"IU "
34
WARRANTY :
Larsen & Toubro Limited warrants that all the L&T products
will meet L&T's published product specifications, and will be
free of defects in workmanship and materials for a period of
12 months from the date of invoice from L&T.
35
This warranty does not cover any defect in the product
caused by accident, misuse, neglect, alteration modification
or substitution of any of the components or parts, or any
attempt at internal adjustment by unauthorized service
personnel .
Disclaimer :
Sufficient care is taken to provide all information regarding
the product but L & T does not claim any responsibility for
the damages caused by using the product directly or
indirectly.
36
Manufactured by
LARSEN & TOUBRO LIMITED,
KIADB INDUSTRIAL AREA,
HEBBAL, HOOTAGALLY,
MYSORE – 570 018.
INDIA.
Visit us @ www.lntmps.com
www.lntebg.com
www.larsentoubro.com
Reach us @ mpsinfo@myw.ltindia.com
37
Part No. 4D-060107- Rev. 3
38