 he warranty covers only the replacement and

T 3. TECHNICAL FEATURES
i the repair of the defective parts of the goods
(recognized by the manufacturer). 3.1. Technical data
The Warranty will not be considered in the following Dimensions and weight (see technical catalogue).
cases: Nominal speed 2900/3450 rpm
- Whenever the use of the device does not conform Protection IP 54 (IP 55 Special construction)
to the instructions and information described in this Supply voltage / Frequency: EN
manual. - up to 240V 1~ 50/60 Hz
- In case of changes or variations made without - up to 480V 3~ 50/60 Hz
authorization of the manufacturer. Check that the mains frequency and voltage
- In case of technical interventions executed by a non- correspond to the electrical characteristics shown on
authorized personnel. the indicator plate.
- In case of failing to carry out adequate maintenance. The electric data marked on the label are referred to
1.5. Technical assistance the nominal power of the motor.
Any further information about the documentation, Sound pressure: < 70 dB (A).
technical assistance and spare parts, shall be Max. starts per hour: 30 at regular intervals (15 for
requested from: Calpeda S.p.A. (paragraph 1.2). MXH 206-406, MXH 20-32-48).
Maximum permissible pressure in the pump casing: 80
2. TECHNICAL DESCRIPTION m (8 bar), 100 m (10 bar) for MXH 20-32-48.
Horizontal Multi-Stage Close Coupled Pumps in The max. inlet water pressure: PN (Pa) - Hmax (Pa).
stainless steel.
MXH: version in stainless steel (AISI 304). 3.2. Operating conditions
MXHL: version in stainless steel (AISI 316). Installation in well ventilated location protected from
the weather, with a maximum ambient temperature of
2.1. Intended use 40 °C.
For clean liquids: non-explosive and non-flammable,
non-hazardous for health or the environment, non- 4. SAFETY
aggressive for pump materials, not containing
abrasives, solid or fibrous particles. 4.1. General provisions
With seal rings in EPDM the pump is not suitable for  efore using the product it is necessary to
B
use with oil. know all the safety indications.
Liquid temperature from - 15 °C to + 110 °C.
Carefully read all operating instructions and the
2.2. Improper use indications defined for the different steps: from
The device is designed and built only for the purpose transportation to disposal.
described in paragraph 2.1. The specialized technicians must carefully comply
Improper use of the device is forbidden, as is with all applicable standards and laws, including local
use under conditions other than those indicated regulations of the country where the pump is sold.
in these instructions. The device has been built in conformity with the current
Improper use of the product reduces the safety and safety laws. The improper use could damage people,
the efficiency of the device, Calpeda shall not be
responsible for failure or accident due to improper use. animals and objects.
Do not use in ponds, tanks or swimming pools The manufacturer declines any liability in the event of
or where people may enter or come into contact damage due to improper use or use under conditions
with the water. other than those indicated on the name-plate and in
these instructions.
2.3. Marking Follow the routine maintenance schedules and
The following picture is a copy of the name-plate that is
on the external case of the pump.
i the promptly replace damaged parts, this will
allows the device to work in the best conditions.
Use only original spare parts provided from Calpeda
0 Manufacturer S.p.A or from an authorized distributor.
1 Type 0 11
2 Delivery
Montorso (VI) Italy IT 00142630243 Made in Italy
Don’t remove or change the labels placed on
3 Head 1 XXXXXXX AAAAXXXXX 12 the device.
4 Rated power 2 Q min/max X/X m3/h
5 Supply voltage 3 H max/min X/X m
6 Frequency 21 ESCC2900 MEI≥ XX η Do not start the device in case of defects or damaged
7 Nom. motor current XXXXXXXX 14 parts.
8 Rotation speed rpm Maintenance operations, requiring full or partial
9 Operation Duty
10 Insul. class disassembly of the device, must be done only
11 Certifications 11 after disconnection from the supply.
12 AAAA Year of 6
4
manufacture XX kW (XXHp) S.F. 22 4.2. Safety devices
12 XXXX Serial number 5 230∆/400Y V3~50Hz (XX μF) X/X A 7
13 Weight 8 n XXXX/min l.cl. X
The device has an external case that prevents any
S1 10
14 Notes V % cos contact with internal parts.
XXX XXX XXX XXX 9
15 Voltage 15
16 % Load 16
XXX XXX XXX XXX XX kg
IP XX
13 4.3. Residual risks
17 Power factor XXX XXX XXX XXX 19
17 The appliance, designed for use, when used in-line with
18 Efficiency IEC 60034-1 IECX/X 20
19 Protection 18 the design and safety rules, doesn’t have residual risks.
20 Motor Efficiency
21 Pump Efficiency 4.4. Information and Safety signals
22 Capacitor For this kind of product there will not be any signals
on the product.

MXH Rev25 - Operating Instructions Page 9 / 64

MXH Rev25.indd 9 24/05/21 09:54