You are on page 1of 2

Dr.

Staiger Mohilo
Industrielle Messtechnik und Prüfsysteme

Compressive-Force Load Cell

1. Application

A high price/performance ratio and robust design


characterize the compressive-force load cell even The measuring element inside the body carries a

Telefon (07172) 184-0 – Telefax (07172) 184-500 – E-Mail:info@staiger-mohilo.de – Internet: http://www.staiger-mohilo.de


in the high measuring ranges. strain gauge full bridge which outputs a voltage
directly proportional to the measurement variable
Their small dimensions allow these load cells to be on the application of a force.
used for measuring static and dynamic forces in
restricted spaces. The measurement force must be applied centri-
cally and without any transverse vectors.
Force sensors of this type have a hermetically Ensure that the sensor is mounted on a smooth
sealed body, allowing it to be used even under and even surface.
dirty and corrosive industrial conditions.

These sensors are used as measuring elements 3. Special features


mainly in
l Measuring ranges from 0 ... 100 N up to
l device manufacture, 0 ...200 kN
l production lines,
l measurement and control systems, l Small dimensions and high measuring ranges
l manufacture of fixtures and special machines
and
l For static and dynamic measurements
Dr. Staiger, Mohilo + Co GmbH – Maierhofstr. 35 – 73547 Lorch

l geological applications
l Made of stainless steel

l Relative span range with unchanged


2. Description mounting position < 0,1 % F.S. (type)

This force sensor type is designed as a flat, circu- l Optional standardization of the rated
lar disc. The load application knob for receiving characteristic
compressive forces is an integral part of the
sensor.

02.09.2003 Compressive-Force Load Cell 108526


Design is subject to change without notice
4. Dimensions
3 hole
Measuring Dimensions [mm] Thread
Range / size frequency
art.no.
ØD1 ØD2 ØD3 ØD4 ØD5 H1 H2 ØT N ØA ØB ØC K L M G [kHz]
0...100 N 12915 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 2
0...200 N 12967 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 3
0...500 N 12916 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 5
0...1 kN 12968 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 8
0...2 kN 12917 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 11
0...5 kN 12969 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 17
0...10 kN 12918 31,8 29,4 20,6 8,1 19,0 9,9 8,1 25,4 3 - 3 2 - 40 2,5 M 2,5 25
0...20 kN 12970 38,1 35,0 28,0 10,7 27,0 16,0 14,0 31,5 3 - 4,5 3 - 45 3 M 2,5 25
0...50 kN 12919 38,1 35,0 28,0 10,7 27,0 16,0 14,0 31,5 3 - 4,5 3 - 45 3 M 2,5 40
0...100 kN 12971 50,8 48,0 36,0 15,2 33,0 25,4 22,4 42,0 6 7 4,5 3 11 46 6 M4 40
0...200 kN 12920 76,2 74,0 46,0 20,0 45,0 38,1 33,5 60,0 6 7 4,5 3 11 46 6 M4 40

Overload safe: 150 % over capacity Dyna

mic performance:
recommended 50 % of capacity
permitted 70 % of capacity

Mounting:
Bottom side with three 3 mm (M 2.5) or 6 mm (M 4) deep mount-
ing holes on diameter T, sharing 120°, see table.
Material: High-grade stainless steel 1.4542

Electrical connection:

Measuring range 0 ... 10 kN screened, teflon-insulated cable


ø 2 mm, length 2 m, at sensor body 40 mm anti-kink coil, bend-
ing radius 25 mm min, with connection plug Tuchel 6-poles.

Measuring range 0 ... 20 kN screened, teflon-insulated cable


ø 3 mm, length 2 m, at sensor body 40 mm anti-kink coil, bend-
ing radius 30 mm min, with connection plug Tuchel 6-poles.

Protection class: according to DIN 40050 IP 54


Electrical specifications Weight: approx. 0.1 kg to 1.8 kg
Bridge resistance:
full bridge, foil-type strain gauge 350 , nominal*

Excitation:
Pin connection:
Measuring range 0 ... 1000 N max. 5 V DC
Pin wire signal
Measuring range 0 ... 2000 N max. 10 V DC
Output: 1.5 mV/V, nominal* 1 brown excitation -
Calibration resistor: 80 k ± 0,1 % 2 white excitation +
The bridge output voltage, resulting from a shunt of this value, is 3 (blank) shield
stated in the calibration certificate. 4 yellow signal output +
*Deviations from the stated value are possible. 5 green signal output -

Environmental conditions Assembly instruction area of support:


Height: ≈ sensor height
Operating temperature: - 20 °C ... + 100 °C Hardness: 60 HCR
Compensated temperature: +15 °C ... + 70 °C Evenness: < 5 µm
Temperature effect zero: ± 0.02 % F.S./K
Parallelism: < 30 µm
Temperature effect span: + 0.03 % Rdg./K

Mechanical specifications

Non-linearity:
5. Order Information
e.g Compressive-force load cell, 0...100 kN:
Measuring range 0 ... 1 kN < 0.25 % F.S.
Measuring range 0 ... 2 kN < 0.5 % F.S.
108526 – 100 kN – 12971 – 1
Hysteresis:
Measuring range 0 ... 1 kN < 0.15 % F.S.
Measuring range 0 ... 2 kN < 0.5 % F.S. Data sheet Meas. range Art.-No. Option 1mV/V
Repeatability: < 0.1 % F.S.

Deflection, full scale: 10 µm ... 80 µm

108526