Professional Documents
Culture Documents
Destressing Calculation Table
Destressing Calculation Table
60 Kg Rail Type Grade of Rail Sectional Area (sq mm) Modulus of Elasticity (GPa)
A 90 UTS / 880 MPa 7686 200
B 110 UTS / 1080 MPa HH 7670 200
Rail Type Decliped Length (m) Prevailing Temp (Tp) Destressing Temp (Td)
A 900 27 39
Required Anchor Length (m) Required Pull Force (Ton) Required Gap (mm)
30 21.66 87.416