This document provides a table of technical parameters for a refrigeration unit. The unit has a cooling capacity of 2286 kW and uses chilled water at 32-37°C, cooling water at 14-8°C, steam at 0.8 MPa and hot water at 89-79°C. It requires 42.6 A of 3-phase 400V 50Hz power and has overall dimensions of 5900x3100x3700 mm.
This document provides a table of technical parameters for a refrigeration unit. The unit has a cooling capacity of 2286 kW and uses chilled water at 32-37°C, cooling water at 14-8°C, steam at 0.8 MPa and hot water at 89-79°C. It requires 42.6 A of 3-phase 400V 50Hz power and has overall dimensions of 5900x3100x3700 mm.
This document provides a table of technical parameters for a refrigeration unit. The unit has a cooling capacity of 2286 kW and uses chilled water at 32-37°C, cooling water at 14-8°C, steam at 0.8 MPa and hot water at 89-79°C. It requires 42.6 A of 3-phase 400V 50Hz power and has overall dimensions of 5900x3100x3700 mm.
USRt 650 Cooling capacity kW 2286 4 10 kcal/h 196.6 Inlet/outlet temperature ℃ 14/8 Flow m3/h 327.7 Chilled water Pressure loss mH2O 10 Connection diameter (DN) mm 200 Inlet/outlet temperature ℃ 32/37 Flow m3/h 840 Cooling water Pressure loss mH2O 9 Connection diameter (DN) mm 300 Consumption kg/h 713 Steam pressure (G) MPa 0.8 Steam condensate temperature ℃ ≤95 Steam Steam condensate back pressure (G) MPa ≤0.05 (190Rt) Steam pipe diameter (DN) mm 40 Steam electric modulating valve diameter (DN) mm 40 Steam condensate pipe diameter (DN) mm 25 Inlet/outlet temperature ℃ 89/79 Hot water Consumption t/h(m3/h) 183(189.5) (460Rt) Pressure loss mH2O 6 Connection diameter (DN) mm 150 Power supply 3ф-400V –50Hz Electrical data Total current A 42.6 Electric power kW 12.9 Length 5900 Overall Width mm 3100 dimensions Height 3700 Operating weight 31 t Shipping weight 22 Note: (1) Values for steam, chilled water, hot water and cooling water in the above table are for nominal operation conditions, and can be properly adjusted in actual operation. (2) Steam pressure 0.8MPa (G) refers to unit inlet pressure without any valve pressure loss. The lowest outlet temperature for chilled water is 5℃. (3) Cooling capacity can be adjusted in a range of 20 ~100%. Chilled water flow can be adjusted in the range of 60 ~120%. (4) On the chilled, hot and cooling water side scale factor will be 0.0001m2h℃/kcal. (5) The highest chilled, hot and cooling water box pressure bearing capacity of normal pressure type units is 0.8MPa (G). (6) The material of tubes in Absorber and Condenser is S31603 (316L), but the material of tube-sheet and water box is still carbon steel.