You are on page 1of 1

PROJECT

OWNER

T2-3 T2-3.5 T2-4.5 T2-5 T2-3 T2-3.5 T2-4.5 T2-5 Ortigas&Company


Limited Partnership
9/F ORTIGAS BUILDING,ORTIGAS AVENUE, PASIG CITY
TELEPHONE: (632)631-1231 TO 38 FAX:(632)631-6517
1200 1200 1200 1200 1200
1200
TYP CORNER TYP END TYP CORNER

TYP CORNER

TYP CORNER
1200

1200
T2-D T2-D THOMAS F. MIRASOL

450

450

450

450
CHIEF OPERATING OFFICER, SENIOR VICE
PRESIDENT & GENERAL MANAGER
REAL ESTATE DIVISION

RED - Technical Planning Department

TECHNICAL PLANNING MANAGER

ARCHITECT OF RECORD

GF & Partners
A r c h i t e c t s

ANNETTE F. GADDI-LIGANOR
A R C H I T E C T
PRC REG. NO. : 6813 DATE: 11-12-1982 TIN : 108-782-800
PTR NO. : 4754954 DATE: 01-12-2015 PLACE : MAKATI CITY
TEODORO H. NARCISO TEOFILO A. SANTIAGO JR.
ANNETTE F. GADDI-LIGANOR ARNULFO M. VILLANUEVA
XAVIER ANTONIO J. GARCIA
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
TELEPHONE (632) 553-7232 FAX (632) 553-7230 E-MAIL: postmaster@gfparchitects.com

STRUCTURAL

450 450
450

450

450

450
incorporated
ASSOCIATES JOSE A. SY
T2-F T2-F STRUCTURAL ENGINEER
1200

1200
Unit 504 Pryce Center, 1179 Chino Roces Avenue
cor. Bagtican St., Makati City REG. NO. 22404 TIN 123-489-697
Telephone No. 896-97-04 to 05
Fax No. 896-97-60 to 61 PTR NO. 5330036 DATE 01-07-16
e-mail address: info@sysquared.com PLACE MAKATI CITY

ELECTRICAL
1200 1200
EDGE OF EBCRUZ & PARTNERS
ELECTRICAL ENGINEERS
OPNG BELOW 1335 A. MABINI ST., KALOOKAN CITY.
TEL. NOS. 287-5631 288-7054
email : ebc@philonline.com.ph

TYP END
E F R E N B. C R U Z

1200

1200
PROFESSIONAL ELECTRICAL ENGINEER

MECHANICAL

DCCD ENGINEERING CORPORATION


SOL BUILDING 112 AMORSOLO ST., MAKATI M.M.
TEL. NOS. 892-45-86 TO 89

PROF. MECHANICAL ENGINEER

PTR NO. REG. NO.


ISSUED ON. TIN
ISSUED AT

DCCD ENGINEERING CORPORATION


SOL BUILDING 112 AMORSOLO ST., MAKATI M.M.
TEL. NOS. 892-45-86 TO 89

SANITARY ENGINEER

PTR NO. REG. NO.


ISSUED ON. TIN
ISSUED AT

FIRE PROTECTION
DCCD ENGINEERING CORPORATION
SOL BUILDING 112 AMORSOLO ST., MAKATI M.M.
TEL. NOS. 892-45-86 TO 89

FIRE PROTECTION ENGINEER

PTR NO. REG. NO.


ISSUED ON. TIN
ISSUED AT
TYP END

CONSTRUCTION MANAGER
1100

T2-H T2-H

NOTES: NOTES: QUANTITY SURVEYOR

1. ALL CROSSTIES AND HOOPS TO BE T16 @ 120mm VERTICAL SPACING WITH Fy = 75 KSI, TYPICAL. 1. ALL CROSSTIES AND HOOPS TO BE T16 @ 120mm VERTICAL SPACING WITH Fy = 75 KSI, TYPICAL.
AS AN ALTERNATIVE, T16 @ 100mm VERTICAL SPACING WITH Fy = 60 KSI MAY BE USED. AS AN ALTERNATIVE, T16 @ 100mm VERTICAL SPACING WITH Fy = 60 KSI MAY BE USED.

2. CONCRETE COVER TO REINFORCING IS 25mm. 2. CONCRETE COVER TO REINFORCING IS 25mm. Arcadis Philippines, Inc.
4th Floor King's Court 1, 2129 Pasong Tamo Makati City

3. ADDED VERTICAL REINFORCING IN BOUNDARY ELEMENTS AT WALL ENDS TO MATCH SIZE OF WALL REINFORCING. 3. ADDED VERTICAL REINFORCING IN BOUNDARY ELEMENTS AT WALL ENDS TO MATCH SIZE OF WALL REINFORCING. Tel: +632 8112971
E-mail: info-ph@arcadis.com
Fax: +632 8112071
www.arcadis.com
AT CORNERS, MATCH REINFORCING SIZE OF THE LARGER OF THE TWO WALLS. AT CORNERS, MATCH REINFORCING SIZE OF THE LARGER OF THE TWO WALLS.
REVISIONS
NO. DATE DESCRIPTION

LEVEL 01 MEZZANINE LEVELS 02 - 07


11 1 : 50 13 1 : 50

NOTES:

SHOULD THERE BE DISCREPANCIES, CONFLICTS


AND/OR AMBIGUITIES ON THE CONSTRUCTION
DOCUMENTS (ie. ARCH'L., ENGINEERING DRAWINGS,
TECH'L. SPECS ETC.), THE CONTRACTOR SHOULD
FIRST CALL THE ATTENTION OF THE DESIGNERS FOR
CLARIFICATION BEFORE PROCEEDING WITH THE WORK
ON THE AREA CONCERNED.

THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS A


PROPERTY OF ORTIGAS AND COMPANY, LIMITED
PARTNERSHIP, AND AS SUCH MUST NOT BE
REPRODUCED OR COPIED IN PART OR IN WHOLE
WITHOUT THEIR CONSENT. ALL DRAWINGS ARE TO BE
RETURNED WHEN NO LONGER IN USE.
REPUBLIC ACT 545

PURPOSE OF ISSUANCE

PROGRESS PLANS

SHEET CONTENTS

TOWER 2 SHEAR WALL SECTIONS

DRAWN SHEET NO.


N DATE
REVISED S3.42
CHECKED
KEYPLAN PROJECT NUMBER : 140721

C:\Revit 2015 Project Files\CapitolCommParcelF__CD_WS2015_ym.rvt 6/16/2017 4:44:14 PM MAG

You might also like