Solus* AP26 Water Technologies & Solutions

fact sheet
all-polymer internal boiler treatment
• Patented Boiler Terpolymer (BTP) provides highly 3. Alter the surface charge of the suspended
effective control of hardness and iron deposition particles as well as the boiler tube surfaces,
• All-polymer treatment reduces the potential for reducing the particle-particle attraction and the
boiler tube failures due to waterside deposits attraction between particles and the boiler tube
walls.
• Enhanced rejection of iron, magnesium, and silica
contaminants to the blowdown translates to This results in significantly reduced scale potential
cleaner, more efficient boilers and cleaner heat transfer surfaces, especially during
• Easily tested product tracer for convenient feed upsets in control or variations in feedwater hardness.
rate control
• FDA 21CFR173.310 and Health Canada approved
for treatment of steam that may contact food. NSF-
USDA G6 and Kosher.

description and use


Solus AP26 is the latest technological innovation in
boiler scale control and internal treatment from SUEZ.
This all-polymer technology is designed to meet the
deposit control performance needs of modern low-to-
intermediate pressure steam boilers (up to 900 psig –
62 barg) and is a cost effective, easy-to-use treatment
in a stable, liquid formulation.

The BTP contained in Solus AP26 is multifunctional and treatment and feeding requirements
limits deposits through its ability to:
Feed point - For systems with high-purity feedwater
1. Maintain incoming feedwater contaminants, such (reverse osmosis or demineralized-quality make-up),
as calcium and magnesium, in soluble form for the recommended feed point for Solus AP26 is
efficient rejection to the boiler blowdown; directly into the boiler. In softened water systems, it
2. Distort crystal growth, thus reducing the size of is recommended that the product be fed to the boiler
particles that are formed; feedwater downstream of the boiler feed pumps.
Feeding directly to the deaerator is also acceptable if
the feedwater is not used for attemperation.
Feed rate - Proper treatment levels for Solus AP26 packaging information
depend on many factors specific to a given installation.
The product should be used in accordance with the Solus AP26 is available in a wide variety of
control procedures that SUEZ establishes for a specific customized containers and delivery methods. Contact
application. your SUEZ representative for details.

Dilution - Solus AP26 may be fed neat or diluted to any


convenient strength with good quality condensate, storage
demineralized water, or feedwater. Dilution using
softened water is not preferred, but usually acceptable. Store Solus AP26 at a moderate temperature and
protect from freezing. If frozen, thaw completely and
Equipment - Chemical feed should be through a 304 or mix thoroughly prior to use.
316 stainless steel injection nozzle.
safety
Regulatory – Solus AP26 is approved per FDA
21CFR173.310 and Health Canada for treatment of Please reference the MSDS for detailed safety
steam that may contact food to a maximum dosage of information regarding Solus AP26.
1282 ppm in the boiler water. It is also approved per
NSF-USDA G6 and is Kosher.

general properties
Please reference the Material Safety Data Sheet
(MSDS) for the physical properties of Solus AP26.