You are on page 1of 4

Dhirendra Gaurav (B.

Tech Chemical Engineering)


+91-9260948972
dhirendarkumargaurav@gmail.com
Village:-.Koranpatti, Ta:- Mirzapur, Dist.:- Mirzapur, Uttar Pradesh (221301)

CAREER OBJECTIVES :-

 To be part of a progressive organization to contribute in its business performance anddevelopment


by virtue of my technical and interpersonal skills.

EXPERIENCE SUMMARY
 An enthusiastic professional with over 10 years and 1 months of experiences
in Production Units, having well working experiences in Chemicals Unit &
Petrochemical Refinery industry.

1) Current Employee:- Satyesh Brinechem Pvt. Ltd – Nakhatrana Hajipir


Designation: Engineer Production
Tenure: January 2020 to Till Date

2) Previous Employee : -Mundra LPG Terminal Pvt. Ltd- kutch Designation:


- Commissioning Engineer (Production)
Tenure: September 2019 to December 2019

3) Previous Employee : Reliance Industries Limited- Jamnagar Designation:


- Shift Field Engineer (Production)
Tenure: February 2018 to August 2019

4) Previous Employee : -Gail India Limited (Contract of Global S.S


Construction Pvt. Ltd) – Pata
Designation: - Operational Assistant (Production)
Tenure: August 2013 to February 2018

SUMMARY OF RESPONSIBILITIES

• Responsible for entire Bromine Manufacturing Process and also raw materialprocessing
and handling.
• Monitoring and Controlling DCS control parameter to achieve required quality ofbromine
accordance with targeted.
• Shift wise plant parameters monitoring.
• Safety work permits preparation.
• Define Daily Basis plant objectives.
• Good Knowledge about SAP & Microsoft Office Tools.
• Plant startup and shutdown activities
• Preparation of shift Production Report.
• Handling ISO tanker filling , dispatch and documents work
• Bromine Bottle Filling From Semi Auto Filling Machine
• Implementing action plans effectively to maximize overall equipment efficiency ofproduction
machines operations as per the capacity available.
• Analysis of rejection and find root cause for corrective and preventive action.
• Taken initiative to implement technical suggestion and modification work in order toachieve to
minimize power consumption and reduce operating cost.
• Chemical cleaning, Steam flushing, Hydro test of the pipelines, Nitrogen purging andFlushing of
pipelines , Pressure and leak testing of pipeline,
• Responsible for handling plant emergencies and operate the plant at optimumconditions.
• Carryout PSSR & escalate to concerned department.
• Exposure to read P&ID
• Involved in Delayed Coker Unit Revamp Project Commissioning:
• Responsible for safe execution of Erection and installation Activities.
• Follow proper safety procedures during execution of project, solved conflicts in job
• To Prepare Risk Assessment (RA), Hazard Identification and Task Risk Assessment
• Planning and monitoring erection and pre-commissioning and commissioning activity like Hydro
testing, flushing, pneumatic test, etc. for revamp project of delayed Coker
• Reviewing P&ID for Mechanical Clearance and Box-up, with cooperation of Quality Analysis
Engineer and maintenance Engineer
• Handle LPG column, propane column butane column in LPG plant
• Worked in gas processing unit & gas sweetening unit
• Worked in C2/C3 recovery plant
• Report Preparation (daily production, raw material consumption, Utility Consumption)
• Issuing permits to contractors, service dept. and field workers where necessary.
• Handle stream turbine
• Plant start-up and shutdown activities, Co-ordinate with control room in case of emergencies.
• Handling equipment like Booster Gas ,Turbo Expander , Fractionation Column ,Cold box (Chiller)
System, Centrifugal / Positive displacement pumps ,Regeneration gas System, Gas turbine, Fixed bed
gas dryer
MATERIAL HANDLING

• BROMINE, HBR, CHLORINE, H2SO4, SO2,

 HANDLING EQUIPMENT:-

• Distillation Column under Vacuum and Steam Distillation.


• Kettle type Reboiler, Heat Exchanger, Bromine Storage Receiver.
• Absorber, Stripper Tower, Venturi, Scrubber.
• Centrifugal and Reciprocating Pump.
• Vaccum Pump, Steam Ejector.
• Purification Tower for Impurity remove and product quality maintain

 HEALTH, SAFETY AND ENVIRONMENTS

• Knowledge of SOP, HIRA, CARA, SWOT, EAI, IPNE, RORPAU, RCA, CAPA,5S, Kaizen.
• Good experience in working with cold and hot work permits system
• Equipment’s isolation and cleaning procedure, vessel entry procedure, Nitrogenpurging of
the equipment for hydrocarbon freeing and air freeing.
• Work permit system and confined space entry.
• Attended Fire & Safety and First Aid Training.
• Familiar with operation of fire extinguishers like foam, DCP, CO2 etc.
• Knowledge of Personal Protective Equipment and breathing apparatus.
• I am ERT team member (Emergency response team)
 Academic details:-

Standard Stream/ Board/ Institute Result


/Degree Branch University Name

B.TECH Chemical C.C.S University SCRIET MEERUT 68.60%


Engineering Meerut

PCM
H.S.C. U.P BORAD SCMSICP SR NagarBhadohi 57.5.%

IBSN INTER COLLEGE SR


S.S.C. Science U.P BOARD Nagar Bhadohi 54%

 Personal Details:-

Name: Dhirendra kumar gaurav


Date of Birth: 09h May,1988
Gender: Male
Marital Status: Married
Nationality: Indian
Hobby: Cricket,Chess & Listening Music
Language English ,Hindi & Gujarati
Knowledge

Declaration:-

I hereby declare that all the above information in this resume is true and correct to thebest of my
knowledge.

Your Faithfully
DHIRENDRA KU. GAURAV