You are on page 1of 6

Bellhousing_coupling_uk.

qxd 28-07-2008 12:16 Pagina 5 (1,1)

Bellhousing Series
SERIES LMC
LMC series monobloc bell housings are used to connect
between UNEL-MEC electric motors (form B3 - B5) and a
loide range of hydraulic pumps available on the internatio-
nal market.
With special machining, they can become motor bases on
which it is possible to fit standard flanges produced by
MP Filtri S.P.A. (MODUL-2).
Due to their considerable flexibility and the vast range of
the LMC series monobloc bell housings are suitable for
most applications, and offer an operational range from
0.5 kW
size 80 electric motors to 30 kW, frame size 225 electric
motors.

Te c h n i c a l d a t a

Material Fluids compatibility


• Monobloc Bellhousing • Motor bases compatibility with:
Aluminium.
Mineral oil
• Pump Flange Types HH-HL-HM-HR-HV-HG as per ISO 6743/4
Aluminium.
Wa t e r-based emulsions
• Foot Bracket Types HFAE – HFAS as per ISO 6743/4
Aluminium.
Water-glycol
Types HFC as per ISO 6743/4
Ask for anodized version.

Te m p e r a t u re range
• Working temperature
from -30°C to +80°C
For values outside these temperature s ,
please consult our Sales Network Organisation.

Special applications
• For applications not included in this brochure, please consult our technical office.

1
Bellhousing_coupling_uk.qxd 28-07-2008 12:16 Pagina 5 (3,1)

How to use this catalogue

This catalogue provides the technical and dimensional characteristics to correctly select
the LMC low noise bellhousing.

• Once the motor power and the type of hydraulic pump have • All the available combinations between motor base
been selected, you will need to determine the corre c t and flanges are shown in chart 2. With the information,
flange pump for the type of motor & pump. establish exactly the H1 dimensions of the LMC
bellhousing and the exact ordering code.

Version available
• Monobloc bellhousing: bellhousing complete with machined pump interface; flange code FS*
• MODUL 2 bellhousing: pump interface machined on a supplementary flange and assembled to the monobloc bellhousing;
flange code FR* - F5* - F6*

Practical example of calculating the height H1

DATA

A
Am Motor shaft length Am B Ap
B Spider element Thickness H1 Ideal
Ap Total length of the pump shaft (including pump spigot)

• The H1 length has been calculated using the following:


Am + B + Ap,
Optimum solution: H1 ideal is < or = bellhousing length.
• In the first instance, we try to use a monobloc bell housing.

In the event that:


1. A bell housing that meets the above condition does not exist;
2. The drilling of the pump is not compatible with a standard flange;
We use the flanges described later.
In this case, the bell housing is composite (MODUL-2).

NB. For coupling selection see “GENERAL CATALOGUE OF COMPONENTS FOR MOTOR-PUMP COUPLINGS
ARRANGEMENTS”

2
Bellhousing_coupling_uk.qxd 28-07-2008 12:16 Pagina 7 (1,1)

Bell housing

Monobloc bell housing - Additional assembled flange

BCD Monobloc bell housing Additional flange


D

H2
P F H1
H1

The additional flange, if request, is supplied already fitted on the bell housing (MODUL-2).
Drive coupling not included in the ordering code- please see page 41.
– For technical information, see paragraph “DRIVE COUPLINGS” page 41
– For loose components see pages 7-8-9-10

NB Drill the hole in the cover of the tank at least 2 mm larger than measurement D5

CHART 1
4 poles 1500 rpm motor LMC monobloc bell housing dimensions
Motor Motor Foot bracket
Frame Size kW Hp shaft Bell housing code Code D1 D2 D3 D4 D5 H1 H2 F. Nr. P Nr.
80 0.53-0.75 0.75-1 19x40 LMC 200 PDM A 200 130 165 200 125 135 18 M10 4 11 4
90 1.1-1.5 1.5-2 24x50 LMC 200 PDM A 200 130 165 200 125 135 18 M10 4 11 4
100-112 2.2-4 3-5.5 28x60 LMC 250 PDM A 250 180 215 250 175 186 19 M12 4 14 4
132 5.5-7.5 7.5-12.5 38x80 LMC 300 PDM A 300 230 265 300 230 235 23 M12 4 14 4
160 11-15 15-20 42x110 LMC 350 PDM A 350 250 300 350 240 254 31 M16 4 18 4
180 18.5-22 25-30 48x110 LMC 350 PDM A 350 250 300 350 240 254 31 M16 4 18 4
200 37 45 55x140 LMC 400 / 300 350 400 280 305 31 M16 8 - -
225 37-45 50-60 60x140 LMC 450 / 350 400 450 320 350 31 M16 8 - -

See
Tab.
2

To determine dimension H1 of bell-housing, see Chart 2


To determine foot bracket dimension, see Page 50
To determine pump flange dimension, see refer to the pump manufacturers technical literature.

3
Bellhousing_coupling_uk.qxd 28-07-2008 12:16 Pagina 7 (3,1)

LMC bell housing H1 height

CHART 2
Monobloc Modul 2
Code H1 Notes Code H1 Notes
F S J *** 100 LMC 200 F 5 A *** 218
Additional
F S W* * * 125 LMC 200 F 5 B *** 224 flange
F S M* * * 114 LMC 250 F 6 A *** 239 for
F S Q *** 136 LMC 250 F 6 B *** 252 LMC 350

F S T* * * 155 LMC 300 F 5 A *** 228


Additional
F S X *** 170 LMC 300 F 5 B *** 234 flange

F S Y* * * 178 LMC 350 F 6 A *** 247 for


LMC 400
F S U *** 194 LMC 350 F 6 B *** 260
F S V* * * 202 LMC 400 F 5 A *** 276 Additional
F S Z *** 250 LMC 450 F 5 B *** 234 flange

F 6 A *** 295 for


LMC 450
F 6 B *** 308
MODUL 2
Code H1 Notes
F R A* * * 117
Additional
F R B* * * 125 flange
F R C* * * 133 for
F R D *** 158
LMC 200

F R A* * * 153 Additional
flange
F R B* * * 156
for
F R C* * * 161 LMC 250
F R A* * * 185
F R B* * * 191
Additional
F R C* * * 193 flange
F R D *** 201 for
F 5 A *** 192 LMC 300
F 5 B *** 198

Additional flanges Recommended tightening torque


tightening torq u e for motor/pump mounting scre w s
• FR* 18 Nm • M6 10 Nm • M16 205 Nm
• F5* 100 Nm • M8 24 Nm • M18 280 Nm
• F6* 180 Nm • M10 50 Nm • M20 400 Nm
• M12 84 Nm • M22 530 Nm
• M14 135 Nm • M24 690 Nm

These values are calculated at 70% of the max admissible load.


In these special conditions the bolt’s body will undergo an average 60-70% of max. admissible load during tightening.
These values are valid for UNI 5737 hexagon head screws and cylinder head screws with UNI 5931 built in hexagon
with 8.8 resistance class, and torques gradually modulated with dynamometric screwer.
If tightening is carried out with hydraulic power tool with torque control system, it is recommended that the tightening
torque is decreased by 10%.

N B . The 3 asterisks in the table represent the 3 numerals determining the pump drilling code (see Page 39).

4
Bellhousing_coupling_uk.qxd 28-07-2008 12:16 Pagina 7 (5,1)

Ordering code

Monobloc bell housing

LMC 2 50 - A - FS Q 0 72 - P00

Series

Nominal
size
see chart 1
Page 3

Product
revision number

Pump flange
see Page 39

P** Personalisation
FG Inspection Hole
45° rounded
of page 39

FI Inspection Hole

Foot bracket

PDM - A - 250

Series Nominal
size
see chart 19
Page 50

NB. For all special requirements please contact our sales dpt.

5
Bellhousing_coupling_uk.qxd 28-07-2008 12:16 Pagina 10 (1,1)

Comparative table

MP Filtri OMT Hydrapp Raja KTR

old code new code code code code code


LMB200A100*** LMC200A*** TH20A*** / R200/99-115/... PK200/3/...
/ LMC200A*** TH1*** HLC1 R200/120-135/... PL200/8/...
LMB250A109*** LMC250A*** TH2*** HLC3 R250/120-135/... PL250/6/...
LMB300A130*** LMC300A*** TH3*** HLC5 R300/155-170/... PL300/4/...
LMB350A179*** LMC350A*** TH4*** HLC8 R350/173-194/... PK350/4/...
/ LMC400A*** TH15*** HLC12 R400/194-210/... PK400/4/...
/ LMC450A*** TH18*** / R450/250-210/... PK450/4/...

You might also like