Galvanized Roof Top Mounting Structure ( 4Panels 545 W)

PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
COLUMN ACCESS DETAILS TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN AS SHOWEN.
180.0 cm

310.0 cm
Base Plates Layout
PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
4 0 . 0 0
1
. 0 c m
410

0 . 0 0
10

0 . 0 0
14

142.00
G

152 H
.0 c
59.0 cm

c m m
6 0.0
1 25.00

18.00
310.00 cm

9.00
C90x45x6 mm
Welded on Base Plate
Detail H :
Connection Plate ( 250x180x6 mm )

Detail G
Angle ( 45x45x6 mm,L=45 mm )
Side View
PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
Slot 8 mm ,L= 30 mm After Welding should be galvanized
For Panels Installation
230
.0 c
m

12

8 2 0 . 0 cm
2

Support Angle 45x45x6 mm Gal. Base Plate 200x200x6 mm


1 4 Slots 14 mm ,L=25 mm
4 Panels Mounting Structure Table
13 Memeber No. Section Length (cm) QTY
1 C75x35x3 mm 142 2
2 C75x35x3 mm 59 2
3 - - -
4 C75x35x3 mm 410 2
5 C75x35x3 mm 152 2
6 C75x35x3 mm 230 4
4 7 L30x30x3 mm 160 2
7 8 L30x30x3 mm 220 1
9 L30x30x3 mm 186 1
10 Base Plate 200x200x6 mm Channel L = 9 cm 4
,C90x45x6mm
5 11 - - -
186.0 12 L45x45x6 mm 4.5 8
cm 13 L45x45x6 mm 4.5 2
14 14 Plate 250x180x6 mm - 2
Bolts M12 3 64
9 180 Panels Bolts M8 3 16
.0 2
cm
Note1: All Memebers are Galvanized including Flanges and Connection Plates
Galvanization not less than 80 Micron Both Side

10 Note2:All bolts SUS 304

Isometric View
PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
Galvanized Roof Top Mounting Structure ( 8Panels 545 W)

PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
200.0 cm 200.0 cm

310.0 cm

Base Plates Layout


PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
4 0 . 0 0
1
. 0 c m
410

0 . 0 0
10

0 . 0 0
14

142.00
G

152 H
.0 c
59.0 cm

c m m
6 0.0
1 25.00

18.00
310.00 cm

9.00
C90x45x6 mm
Welded on Base Plate
Detail H :
Connection Plate ( 250x180x6 mm )

Detail G
Angle ( 45x45x6 mm,L=45 mm )
Side View
PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
108.5 cm Support angle 45x45x6 mm
Purlin one Piece L= 460cm

108.5 cm
12
460.0 cm

235.0 cm 108.5 cm

108.5 cm
13 DETAIL C
Slot 8 mm ,L= 30 mm
6 For Panels Installation
8 Panel Mounting Structure Table

235.0 cm C
Memeber No. Section Length QTY
(cm)
1 1 C75x35x3 mm 142 3
6 8 2 C75x35x3 mm 59 3
3 - - -
4 C75x35x3 mm 410 3
207.0 cm 5 C75x35x3 mm 152 3
6 C75x35x3 mm 460 4
7 L30x30x3 mm 160 3
8 L30x30x3 mm 235 2
200.0 cm B 9 L30x30x3 mm 207 2
4 Base Plate 200x200x6 mm Channel L =
10 ,C90x45x6mm 9 cm 6
11 - - -
207.0 cm 5 12 L45x45x6 mm 4.5 12
13 L45x45x6 mm 4.5 3
14 Plate 250x180x6 mm - 3
14 Bolts M12 3 106
Panels Bolts M8 3 32
200.0 cm
9 7 Note1: All Memebers are Galvanized including Flanges and Connection Plates
Galvanization not less than 80 Micron Both Side
2
Note2: All bolts SUS 304

10

After welding should be galvanized


Detail B:
Gal. Base Plate 200x200x6 mm
4 Slots 14 mm ,L=25 mm
Anchor bolts 12 mm,L=120 mm

PREPARED BY: FUNED BY: PROJECT TITLE: DRAWING TITLE: DESIGN BY: STATUS: DRAWING NO:
TENDER DOCUMENTS.
YEMEN EMERGENCY ELECTRICITY
ACCESS PROJECT CHECKED BY: PROJECT NO: PAPER SIZE:
A3.
PROJECT LOCATION: DRAWING TYPE: APPROVED BY: DATE: SCALE:
YEMEN
460.0 cm
230.0cm

Purlin one piece L=460.0 cm 7.0 cm 7.0 cm 7.0 cm


Purlin , L=230.0 cm 7.0 cm

108.5 cm 108.5 cm 108.5 cm 108.5 cm


108.5 cm 108.5 cm
Slot d=8 mm , L=30 mm
Slot d=8 mm , L=30 cm

140.0 cm
140.0 cm

140.0 cm
140.0 cm

4 Solar Panels (545W) 8 Solar Panels (545W)