Professional Documents
Culture Documents
Cypress Diagnostics
Clinical laboratory specialist for 27 years with 75 million tests sold per year.
27 years of expertise
With 27 years of experience, Cypress Diagnostics is the company to turn
to for quality chemistry analyzers and kits. Thanks to all these years of
experience, we know the tricks of the trade.
Return on investment
After installing your analyzer, our experts will advise you and help you
get the most out of your equipment. In the event of a problem, we help
you immediately through our local partners.
gnostics
A supported implementation
With Cyp le to result
Our certified distributors take care of the smallest details for each new
project. Your analyzer will be installed, and your team trained.
ress Dia
mp
From sa
Overview Biochemistry
Biochemistry5 Stains30
• CYANVision6 • Bacteriology Stains 30
• CYANElite 29010 • Hematology Stains 30
Biochemistry Reagents 14 • Papanicolaou: Histopathology Stains 30
• Electrolytes14 • Auxiliary Products 30
• Enzymes 14
• Lipids16 Rapid Tests 31
• Substrates 16 • Fertility 32
Calibrators and Controls 18 • Cardiac and Tumor Markers 32
• Calibrator 18 • Infectious Diseases 33
• Control Sera 18
• Quality Set 18 Drugs of Abuse 34
25 Liquid Handling 46
Agglutination (Latex) Kits
Blood Grouping 27
• Blood Grouping Reagents 28
• Blood Grouping Subtypes 29
Layout 20140120
Layout 20140120
What do our customers say about the CYANVision? The incubator is optional
• “Structured manipulation similar to working on an Cypress Diagnostics biochemistry kits do not require
automate” external incubation. There is therefore no need nor
• “Stable and trustworthy results” advantage to include an incubator in the analyzer.
• “Compact and robust analyzer” If you wish, we can offer you the CL017 dry incubator.
• “No more stress for reporting biochemistry results”
• “Convenience in the patient follow-up”
The hydraulic system is ultra-short and directly
accessible
The external screen and its advantages By design, we simplified the CYANVision to be more
Did you know that an integrated 7-inch touch screen robust. Small tricks like an ultra-short and directly
of reasonable quality and resolution with associated accessible hydraulic system, increase the detectability of
electronics costs as much if not more than a 23-inch complications and reduce cross-contamination.
computer screen? Here’s how to kill two birds with one stone!
This is the reason why we opted to work with an external
computer screen.
Light-emitting diodes (LEDs) as a light source
Without the heat emitted by the built-in display, there is The CYANVision works with light-emitting diodes (LEDs),
no need for a fan for cooling. not with a conventional halogen lamp!
Without a fan, there is no dust aspiration and therefore This design choice offers many advantages.
no dirt deposit on the optical filters with these harmful LEDs are more energy efficient and reach their maximum
consequences. intensity instantly. This property allows the LEDs to be
turned on just before the test and turned off immediately
Working with an external computer screen offers you after. The consumption of LEDs must therefore be Software Savings
many advantages: : expressed in tests. Software is at the heart of our value proposition. The CYANVision is designed to provide an operational life
• A larger screen The CYANVision can perform 100 000 tests without the Unique, intuitive, clear and informative, it is a real element of over 100 000 tests. As such, the impact of CYANVision
• More value for the same budget costs for lamp replacement. of differentiation from the competition. is expressed in cents per test.
• More convenience of use The simplicity of the required maintenance allows the
• Increased durability of the optical system The functionality of the CYANVision software must be user to carry out most of the tasks. The CYANVision has a
• Less power consumption compared with that of a good biochemistry analyzer. unique washing solution, available at a reasonable price.
• Fewer technical interventions
Clever, right ? The software allows to The CYANVision produces better financial results.
• Structure the information (worklist, test sequencing Investment is limited. It is approximately equivalent to
suggestions, prioritize emergencies...) your billing for 1500 glucose tests to your patients. The
• Standardize the testing process in accordance with CYANVision makes a very positive contribution to your
the accreditation requirements. For example, the institution.
CYANVision will ask to do or redo the auto-zero, blank
or calibration when reaching certain predefined
thresholds.
• Guide the user during the tests. The CYANVision
suggests and encourages steps beneficial to accuracy
and precision. On the other hand, the CYANVision
detects and reports deviations with alerts, graphs,
and measurement ranges. This process increases the
scientific validity of your work.
Layout 20140120
Layout 20140120
Layout 20140120
Performance
Accessibility Training
To optimize the throughput of the CYANElite 290, the We train your team so that you get the most out of the
operator has direct and continuous access to reagents CYANElite 290 and obtain reliable results. Our certified
and samples. On request, the tests are interrupted to distributors ensure that your team masters the operation Management
replace the cuvettes. of the CYANElite 290. We also offer many instructional
videos available 24 hours a day, 7 days a week. Continuity Savings
Autonomy Cypress Diagnostics is a reliable, stock-keeping The simplicity of the required maintenance allows the
With an uninterrupted work autonomy of up to 60 Software manufacturer with excellent logistics and a good user to do most tasks. CYANElite 290 has a unique wash
minutes, the CYANElite 290 frees up your teams for The HI software is at the core of our value proposition. reputation (4.9 out of 5 stars on Google). We have solution available at a reasonable price. The CYANElite
other responsibilities. For clarity, the device shows the Unique, intuitive, clear, and informative, it is a a quality culture, regulatory compliance, and a 290 consumes only 4 mL of distilled water per test.
remaining time. real differentiator from the competition. Ask for a satisfaction policy. You can connect up to 4 analyzers to a single computer
The CYANElite 290 always indicates the available volumes demonstration to appreciate the evidence. For 27 years, we have been making the world a better if you wish.
of reagents and the number of possible tests to optimize place, one test at a time!
your work autonomy. Emergencies With 75 million tests sold, we are one of the largest Financing
The CYANElite 290 handles emergencies in priority. diagnostic manufacturers in Belgium. Through our distributors, we offer multiple options to
Speed Introduce the sample to the software, select the required finance the purchase of your CYANElite 290. Inquire
The CYANElite 290 can process up to 96 tests tests, load the specimen on the analyzer and start testing Durability about your options.
simultaneously. The analyzer performs a measurement in a few seconds The CYANElite 290 is designed to provide aan
every 25 seconds. This enables to run up to 145 tests per The first result arrives in less than six minutes ! operational life of at least 100,000 tests. Therefore, the Return on investment
hour. impact of CYANElite 290 costs only cents per test. The CYANElite 290 brings you better financial results
This biochemistry platform is exclusively available by multiplying by three (3) the number of tests1 per
Start-up through trained distributors to offer you an after- Cypress Diagnostics kit. It allows you to perform 3.8
The start-up procedure is fast and autonomous. The sales service guarantee and extend the lifespan. A times more tests with the same team2. Together, this
CYANElite 290 is ready to work in less than 20 minutes. maintenance contract, with two annual interventions is gain in productivity and capacity multiplies your
You can add samples, select tests, request calibrations, adequate. profitability by 11 !
and quality controls during initialization.
1
Compared to a semi-automated biochemistry analyzer
Layout 20140120
Layout 20140120
2
Compared to a semi-automated biochemistry analyzer
Capacity Performance
• Reagents: • Tests:
19 positions 145 t/h
3 formats (30, 15 and 2 mL) 29 to 290 t/d
Refrigeration • Economies:
• Samples: 3 times more tests per kit
https://cyanelite290.diagnostics.be/mychoice 10 positions
2 formats (tubes or cups of 1 mL)
Simplicity
Technical specifications, • Cuvettes:
• Hydraulic system:
frequently asked questions, 96
2 peristaltic pumps
videos, .... 4 segments
1 diluter
330 µL
Segregation from electronics
• Methodes:
• Needle:
29 from Cypress Diagnostics
Contact detector
3 free choices
Level sensor (mL)
Washing station
Layout 20140120
Standard included
Multi-Standard
CYANElite 290
Whole blood
Colorimetric
CYANVision
Lyophilized
Code Name Method Packing CE
Ultra violet
Mindray*
Endpoint
2 - 25 °C
Plasma
2 - 8 °C
Kinetic
Serum
Liquid
Urine
CSF
Electrolytes
HB0030 Calcium - MONO reagent Arsenazo III • • 2 x 125 mL • • 250 714 • • • • •
HB0030M Calcium - MONO reagent Arsenazo III • • 8 x 30 mL • • 240 685 • • • • •
HB005 Chloride Thiocyanate • • 2 x 125 mL • • 250 757 • • • • • •
HB012 Iron Ferrozine • • 4 x 50 mL • • 200 714 • • • •
HB0320 Magnesium - MONO reagent Xylidyl Blue • • 2 x 125 mL • • 250 714 • • • • •
HB0320M Magnesium - MONO reagent Xylidyl Blue • • 8 x 30 mL • • 240 685 • • • • •
HB014 Phosphorus Phosphomolybdate method • • 2 x 125 mL • • 250 714
HB015 Potassium - Prec NaTPB - Prec. • • 2 x 50 mL • • 100 NA • • • •
HB0340 Sodium - Enzy Enzymatic • • 40 + 20 mL • • NA 200 • • •
HB016 Sodium - Prec Mg-Uranylacetate - Prec. • • 60 mL • • 60 NA • • •
Enzymes
HBE03 α-Amylase CNPG3 • 20 x 2 mL • • 40 133 • • • • •
HBE01 Acid Phosphatase Hillman • 18 x 2 mL • • 36 NA • • •
HBE12 Alkaline Phosphatase IFCC • 60 + 15 mL • • 75 250 • • • •
HBEL05 Creatine Kinase MB Immunoinhibition • C 60 + 15 mL • • 75 227 • • • •
HBEL03 Creatine Kinase NAC Creatine-phosphate / NAC activated • 60 + 15 mL • • 75 250 • • • •
HBEL06 γ-GT Carboxy substrate • 240 + 60 mL • • 300 1090 • • • •
HBEL061 γ-GT Carboxy substrate • 60 + 15 mL • • 75 272 • • • •
HBEL010 GOT (AST) Aspartate / α-ketoglutarate IFCC • 240 + 60 mL • • 300 1000 • • • •
HBEL010M GOT (AST) Aspartate / α-ketoglutarate IFCC • • 6 x 30 + 3 x 15 mL • • 225 750 • • • •
HBEL020 GPT (ALT) Alanine / α-ketoglutarate IFCC • 240 + 60 mL • • 300 1000 • • • •
HBEL020M GPT (ALT) Aspartate / α-ketoglutarate IFCC • • 6 x 30 + 3 x 15 mL • • 225 750 • • • •
HBEL04 Lactate Dehydrogenase DGKC • 240 + 60 mL • • 160 1000 • • •
HBEL041 Lactate Dehydrogenase DGKC • 60 + 15 mL • • 83 250 • • •
HBE09 Lipase Enzymatic • • 4 x 10 mL • • 40 114 • • • •
All our kits are suitable for automatic and semi-automatic biochemistry analyzers.
Applications sheets are available. Please contact your distributor for more details.
* Dedicated Mindray Containers for BS-120, BS-200, BS-200E, BS-230, BS-240, BS-240 Pro
C for controls
Layout 20140120
Layout 20140120
Standard included
Multi-Standard
CYANElite 290
Whole blood
Colorimetric
CYANVision
Lyophilized
Code Name Method Packing CE
Ultra violet
Mindray*
Endpoint
2 - 25 °C
Plasma
2 - 8 °C
Kinetic
Serum
Liquid
Urine
CSF
Lipids
HBL010 Cholesterol CHOD-POD • • 2 x 125 mL • • 250 714 • • • •
HBL010M Cholesterol CHOD-POD • • 8 x 30 mL • • 240 685 • • • •
HBL011 HDL Cholesterol Direct • 120 + 40 mL • • 160 400 • • • •
HBL012 LDL Cholesterol Direct • 120 + 40 mL • • 160 400 • • • •
HBL060 Triglycerides GPO-POD • • 2 x 125 mL • • 250 757 • • • •
HBL060M Triglycerides GPO-POD • • 8 x 30 mL • • 240 727 • • • •
Substrates
HB0010 Albumin Bromocresol green • • 2 x 125 mL • • 250 757 • • • •
HB0010M Albumin Bromocresol green • • 8 x 30 mL • • 240 727 • • • •
HB0260 Bilirubin Direct DMSO • 2 x 125 mL • • 333 833 • • • •
HB0270 Bilirubin Total DMSO • 2 x 125 mL • • 333 833 • • • •
HB0020 Bilirubin Total & Direct DMSO • 2 x 125 mL • • 2 x 166 2 x 416 • • • •
HB0080 Creatinine Jaffe • • 2 x 125 mL • • 250 833 • • • • •
HB0080M Creatinine Jaffe • • 8 x 30 mL • • 240 800 • • • • •
HBL04 Glucose GOD-POD • • 2 x 125 mL • • 250 757 • • • •
HBL04M Glucose GOD-POD • • 8 x 30 mL • • 240 727 • • • •
HB011 Hemoglobin (Conc. (x50)) Drabkin • 4 x 5 mL • • 400 1428 • • •
HT001 HbA1c Turbi Turbidimetric • 30 + 10 mL • • 69 100 • • •
HB020 Urine Total Protein Pyrogallol red • • 2 x 125 mL • • 250 781 • • • •
HB0190 Total Protein Biuret • • 2 x 125 mL • • 250 781 • • • •
HB0190M Total Protein Biuret • • 8 x 30 mL • • 240 750 • • • •
HBL030 Urea Urease GLDH - UV • • 240 + 60 mL • • 200 571 • • • •
HBL020 Uric Acid Uricase-POD • • 2 x 125 mL • • 250 781 • • • • •
HBL020M Uric Acid Uricase-POD • • 8 x 30 mL • • 240 750 • • • • •
* Dedicated Mindray Containers for BS-120, BS-200, BS-200E, BS-230, BS-240, BS-240 Pro
C for controls
Layout 20140120
Layout 20140120
Lyophilized
Code Name Packing CE
2 - 8 °C
Liquid
Calibrator
HBC03 Biochemistry Calibrator • 4 x 3 mL • •
HBC03-S Biochemistry Calibrator Specific • 4 x 3 mL • •
HBS02 Hemoglobin Calibrator • 1 mL • •
HT001S HbA1c Calibrator (4 levels) • 4 x 0,5 mL • •
HBC11 HDL/LDL Calibrator • 1 mL • •
Control Sera
HBC01 Biochemistry Normal Control • 4 x 5 mL • •
HBC01-S Biochemistry Normal Control Specific • 4 x 5 mL • •
HBC02 Biochemistry Pathological Control • 4 x 5 mL • •
HBC02-S Biochemistry Pathological Control Specific • 4 x 5 mL • •
HBC08 CK (NAC & MB) Control • 4 x 2 mL • •
HT001C HbA1c Control (2 levels) • 4 x 0,5 mL • •
HBC10 HDL/LDL Control • 3 x 3 mL • •
Quality Set
HBC123 Biochemistry Quality Set • 3 + 5 + 5 mL • •
The Biochemistry Quality Set includes one vial of Biochemistry Normal Control, one vial of Biochemistry Pathological
Control and one vial of Biochemistry Calibrator.
Contact our distributor to get our application sheets for the most common biochemistry automates.
We sell high-quality instruments and customer service is an integral part of our quality policy.
Our distributors get regular training to ensure that they can provide appropriate technical support for reagents and
throughout the lifecycle of the analyzers. This includes installation, training, preventive maintenance, technical advice,
and support.
Layout 20140120
Layout 20140120
More convenient
reporting with paper printouts Sample volume: User interface:
and USB data transfer to your • 25 μL of whole blood in normal mode • Easy-to-use
computer. • 50 μL of whole blood in pre-diluted mode • Full-LCD touch screen
• External keyboard (in option, via USB)
Measurement: • Languages: English, French, Spanish, Portuguese, and
• Aperture diameter 70 μm (RBC, PLT, WBC) Russian
• Throughput 30 tests/hour
Memory:
Reagent requirement: • 10 000 results, with RBC, PLT, and WBC 3-part histogram
• Diluent - 20 liter (code: CY006-R01)
The sample tube holder • Lyse - 1 liter (code: CY006-R02) Printer:
increases user safety and • Cleaner - 1 liter (code: CY006-R03) • Built-in thermal printer
convenience. • Full report with histograms
The CYANHemato is a fully automated, 20-parameter, Technical Specifications Sampling: • Interface via USB for HP printers
bench-top hematology cell counter. • Open tube system
The analyzer can process 30 samples per hour in 3-part The analyzer determines the following 20 • Automatic sample rotor Power:
WBC differential mode. • Multiple sample profiles • 110/220 V - 50/60 Hz
hematology parameters:
• Advised:
• WBC total white blood cell count
Highlights: • LYM lymphocyte count Cleaning procedure of the aperture: Electronic Stabilizer (> 1 kW Power potential)
• 20 hematology parameters • High-voltage burn No-Break Module (UPS - Uninterruptible Power Supply)
• MON monocyte count
• 3-part WBC differential • GRA granulocyte count • High-pressure back-flush
• Only 25 μL whole blood sample needed • LYM % lymphocyte percentage • Chemical cleaning Operation temperature:
• Easy to use • MON % monocyte percentage • 15 - 30 °C
• Color LCD touch screen • GRA % granulocyte percentage Calibration: • In covered and dry places
• USB connectivity • HGB hemoglobin • Automatic calibration based on ≥ 1 measurement(s) • Stable surface (no vibrations)
• Predilution mode • RBC red blood cell count • Manual calibration using theoretical factors
• Automatic daily maintenance • HCT hematocrit Weight and dimensions:
• Large memory • MCV mean corpuscular volume • 32 x 26 x 36,5 cm (L x W x H)
• Effective QC software • MCH mean corpuscular hemoglobin • 12 kg
• MCHC mean corpuscular hemoglobin concentration
• RDW red blood cell distribution width Order code:
• PLT platelet count • CY006: CYANHemato
• PCT platelet percentage, thrombocrit • CY006-MIBTR: CYANHemato Maintenance kit
• MPV mean platelet volume
• PDW platelet distribution width
• P-LCC platelet large cell count
• P-LCR platelet large cell ratio
Layout 20140120
Layout 20140120
15 - 30 °C
Code Name Packing CE
2 - 8 °C
The CYANCoag 1Ch is a compact and accurate coagulation analyzer. The mechanical detection system will track
the developing coagulum through changes in viscosity. The measurement is therefore totally independent of the
sample’s turbidity. The measurements are started by a countdown timer, avoiding the extra expenses of a start
Reagents pipette.
CY006-R01 Diluent 20 L • •
CY006-R02 Lyse 1L • •
Technical Specifications
CY006-R03 Cleaner 1L • • Advantages: Power:
• Mechanical detection • Power consumption: 16 VA
Cleaners
• Micro-method: up to 100% more tests per kit • Operating voltage: 110/220 V, 50 - 60 HZ
CY006-R04 Hypoclean 1L • • • Countdown start
• Calibration free Schipment includes:
CY006-R05 Clenz 1L • •
• Works on whole blood and plasma • Power adaptor
CY006-R06 Hypoclean CC 100 mL • • • Error control • Ball dispenser
Controls • Cuvettes and balls for 500 tests
Measurement: • Dust cover
CY006-C01A Control vial normal 1 x 2,5 mL • • • Measuring volume: 150 - 400 µL • User manual
• Measures: PT, PTT / APTT, TT, FIB
CY006-C02A Control vial low/normal/high 3 x 2,5 mL • •
• Measuring channel: 1 Order code:
• Speed: Up to 60 tests/hour • CY003: CYANCoag 1Ch
• Incubation positions: 5 • CY003-C01: Cuvettes and balls for 500 tests
• Reagent positions: 1-5
• Value output: INR, ratio or seconds Note: this is a Open system
All reagents and cleaners have an open bottle stability of 120 days after opening.
• Incubation time: 1
These are the only reagents that are calibrated for the CYANHemato (Closed system).
Weight and dimensions:
The hematology control values can be uploaded into the CYANHemato by USB. You can download these (INI) files from
• Weight: 1,1 kg
our website.
• Dimensions: 11,3 x 6,8 x 20,7 cm (W x H x L)
Layout 20140120
Layout 20140120
Lyophilized
Code Name Method Packing CE
CYANCoag
analyzers
Plasma
2 - 8 °C
Other
Reagents
APTT Cephalin Silica
HC00100
(Act. Thromboplastin Time) incl 2x10 mL CaCl2
• 5 x 4 mL • • 400 200 •
HC00200 PT Prothrombin Time Tissue thromboplastin • 4 x 5 mL • • 200 100 •
VonClauss method
HC00300 Fibrinogen
incl 1x120 mL buffer
• 8 x 2 mL • • 160 160 •
Control
HC00500 Coagulation Control Normal + pathological • 4 x (1+1) mL • •
Calibrator
HC00600 Calibrator Fibr/PT Fibrinogen / PT • 4 x 1 mL • •
Layout 20140120
Layout 20140120
Microtitre Plate
Code Name Method Packing CE
Plasma
2 - 8 °C
Serum
Slide
22122 ASO Agglutination test 100 t • • • •
221020 CRP Agglutination test 100 t • • • •
22222 Infectious Mononucleosis Agglutination test 50 t • • • •
22112 RF Agglutination test 100 t • • • •
22202 Rose Bengal Agglutination test 50 t • • • •
22152 RPR carbon 150 t Flocculation 150 t • • • • •
22152S RPR carbon 5 mL Flocculation 5 mL • • • • •
22152-500 RPR carbon 500 t Flocculation 500 t • • • • •
221920 TPHA Micro haemagglutination 200 t • • • • •
22162 Waaler Rose Haemagglutination 50 t • • • •
Layout 20140120
ISO 13485:2016 26
www.diagnostics.be • Belgium • Tel: ++ 32 15 67 67 68 • e-mail: cypress@diagnostics.be
Method T° Test Medium Method T° Test Medium
Agglutination
Agglutination
Whole blood
Whole blood
Code Name Packing CE Code Name Packing CE
Red Blood
Red Blood
Coombs
Coombs
2 - 8 °C
2 - 8 °C
Serum
Serum
Tube
Tube
Slide
Slide
Cells
Cells
Blood Grouping Reagents Blood Grouping Subtypes
401 Anti A • • • 10 x 10 mL - • • • 420 Anti A1 Dolichos bifl. Lectin • • • 5 mL - • • •
01.001-10 Anti A • • • 10 x 10 mL • • • • 412 Anti C • • • 5 mL - • • •
403 Anti AB • • • 10 x 10 mL - • • • 413 Anti c • • • 5 mL - • • •
01.005-10 Anti AB • • • 10 x 10 mL • • • • 435 Anti C(w) • • • 5 mL - • • •
402 Anti B • • • 10 x 10 mL - • • • 437 Anti CDE • • • 10 mL - • • •
01.003-10 Anti B • • • 10 x 10 mL • • • • 424 Anti Cellano • • 5 mL - • •
404 Anti D • • • 10 x 10 mL - • • • 439 Anti D incomplete • • • • 10 mL - • • •
01.011-10 Anti D • • • 10 x 10 mL • • • • 410 Anti E • • • 5 mL - • • •
409 Anti D Blend (IgM+IgG) • • • • 10 x 10 mL - • • • 411 Anti e • • • 5 mL - • • •
401-4S Blood grouping Kit (Anti-A, B, AB, D) • • • 4 x 10 mL - • • • 414 Anti Fy(a) • • 5 mL - • •
401-4S Blood grouping Kit (Anti-A, B, AB, D
• • • 4 x 10 mL - • • •
415 Anti Fy(b) • • 5 mL - • • •
Blend blend)
438 Anti H (A2) • 5 mL - • •
405 AHG - Anti Human Globulin • 10 mL - • • 440 Anti H (A2) Lectin • • 5 mL - • •
436 BSA - Bovine Albumine 22 % • 10 mL - • • • 416 Anti Jk(a) • • 5 mL - • •
406 BSA - Bovine Albumine 30 % • 10 mL - • • • 423 Anti Kell • • • 5 mL - • • •
408 L.I.S.S • 10 mL - • • • 433 Anti Le(a) • • 5 mL - • •
407 Negative control/diluent • • 10 mL - • • • 434 Anti Le(b) • • 5 mL - • •
426 Anti Lu(b) • • 5 mL - • •
419 Anti M • • • 5 mL - • • •
418 Anti N • • • 5 mL - • • •
441 Anti P1 • • • 5 mL - • • •
421 Anti S • • 5 mL - • •
422 Anti s • • 5 mL - • • •
427 Anti Xg(a) • • 2 mL - • •
Layout 20140120
Layout 20140120
15 - 30 °C
Code Name Detection of / Method Packing CE
Liquid
Bacteriology Stains
HS015 Carbol Fuchsin Alcohol-acid resistant Mycobacteria (TB) 1000 mL • • •
HS021 Carbol Gentian Violet Gram positive / negative bacteria 1000 mL • • •
HS001 Gram PVP Gram positive / negative bacteria 4 x 250 mL • • •
HS022 Lugol Stabilized with PVP Gram positive / negative bacteria 1000 mL • • •
HS016 Methylene Blue (Kühne's) Alcohol-acid resistant Mycobacteria (TB) 1000 mL • • •
HS014 Safranin Gram positive / negative bacteria 1000 mL • • •
HS002 TB Ziehl - Neelsen Kit Alcohol-acid resistant Mycobacteria (TB) 3 x 250 mL • • •
Hematology Stains
HS003 Giemsa Romanowsky stain 500 mL • • •
HS005 Quick Panoptic Conc (1:10) kit Romanowsky stain 3 x 100 mL • • •
HS004 May Grünwald Romanowsky stain 500 mL • • •
HS023 Wright Romanowsky stain 500 mL • • •
Papanicolaou: Histopathology Stains
HS006 Harris'Hematoxylin Dr Montalvo - Dr Meissner 500 mL • • •
HS007 Orange G-6 solution Dr Montalvo - Dr Meissner 500 mL • • •
HS009 Polychromic solution EA-50 Dr Montalvo - Dr Meissner 500 mL • • •
Auxiliary Products
HS010 Hayem RBC manual counting 500 mL • • •
HS011 Türk WBC manual counting 500 mL • • •
HS012 Immersion Oil For microscopy 100 mL - • •
Layout 20140120
Layout 20140120
Whole blood
Whole blood
Code Name Packing CE Code Name Packing CE
10 - 30 °C
10 - 30 °C
4 - 30 °C
8 - 30 °C
4 - 30 °C
8 - 30 °C
Dipstrip
Dipstrip
Plasma
Plasma
Faeces
Faeces
Serum
Serum
Other
Other
Urine
Urine
Card
Card
Fertility Infectious Diseases
132-100 hCG Bulk - Dipstrip Bulk • • • • 172-025 Anti HCV Card 25 t - • • • •
132-100/50 hCG - Dipstrip 50 t • • • • 172-050/S Anti HCV Strip 2 x 25 t - • • • •
132-100/100 hCG - Dipstrip 100 t • • • • 322 Chlamydia Ag 20 t - • (1) •
132-200 hCG Bulk - Card Bulk • • • • • • 333 H. Pylori Ab 20 t • • • • • •
132-200/20 hCG - Card 20 t • • • • • • 142-025 HBsAg Card 25 t - • • • •
132-200/50 hCG - Card 50 t • • • • • • 142-050/S HBsAg Strip 2 x 25 t - • • • •
132-200/100 hCG - Card 100 t • • • • • • 337 Strep A 20 t • • (2) •
Cardiac and Tumor Markers
353 Syphilis Ab Rapid C 25 t • • • • • •
Layout 20140120
4 - 30 °C
MDMA
MAMP
Urine
MOR
MTD
AMP
Card
COC
BZO
THC
BAR
PCP
DOA-2CT DOA-2 parameters CT • • 25 t • • • •
DOA-10 DOA-10 parameters • • • • • • • • • • 10 t • • • •
T° Sample Detection
2-8°C
Code Name Packing CE
Serum
Tube
Slide
5011 Salmonella Paratyphi AH 5 mL • • • • •
5021 Salmonella Paratyphi AO 5 mL • • • • •
5031 Salmonella Paratyphi BH 5 mL • • • • •
5041 Salmonella Paratyphi BO 5 mL • • • • •
5051 Salmonella Paratyphi CH 5 mL • • • • •
5061 Salmonella Paratyphi CO 5 mL • • • • •
5071 Salmonella Typhi H 5 mL • • • • •
5081 Salmonella Typhi O 5 mL • • • • •
5091 Brucella Abortus 5 mL • • • • •
5092 Brucella Melitensis 5 mL • • • • •
5101 Proteus OX2 5 mL • • • • •
5111 Proteus OX19 5 mL • • • • •
5121 Proteus OXK 5 mL • • • • •
5901 Bacterial Antigen polyvalent control + 1 mL • • • • •
5902 Bacterial Antigen polyvalent control - 2,5 mL • • • • •
Bacterial Antigens: H, O, AH, AO, BH, BO, CH, CO + 8 x 5 mL
BA-Spec
Ctrls pos/neg + Ctrls
• • • • •
Layout 20140120
Layout 20140120
Technical Specifications
General: Power:
• Measuring method: reflectance photometer • Battery: 8 batteries, type AAA 1,5 V
• Wavelength: 470, 530, 626 nm • 12V DC, 3,33 A; 110/220 V - 50/60 Hz
• Performance in normal mode: 50 tests/h • Power consumption: 15 W
• Performance in quick mode: 120 tests/h
• Memory for up to 2000 samples Printer:
• Reads all Cypress Diagnostics urine strips including • External thermal printer
microalbuminuria • USB connection
• Large color touch screen (480 x 272 pixels) • 32 characters per line
Layout 20140120
ISO 13485:2016 37
www.diagnostics.be • Belgium • Tel: ++ 32 15 67 67 68 • e-mail: cypress@diagnostics.be
Microalbuminuria Urine Strips
Microalbuminuria is one of the first signs of diabetic kidney disease.
Our Urine-2AC strips helps to detect diabetic kidney disease at an early stage,
years before significant damage becomes apparent.
Consistently detectable microalbuminuria is also linked to an increased risk of
developing progressive kidney failure and cardiovascular disease in the future.
Urine Strips Annual screening of microalbuminuria is advised after a diagnosis of diabetes or
hypertension.
Urine Urine Urine Urine Urine
Code & Name Urine-2AC strips deliver on-the-spot results of microalbumin to creatinine ratio
2AC 2GK 2GP 3 10
(CAR). A 24-hour sample collection is therefore no longer required.
Blood •
Urine-2AC strips are readable on the CYANStrip Mini!
Glucose • • • •
Protein • • •
Creatinine •
Microalbumin •
Ketone • •
Microalbumin to Creatinine Ratio
pH • • The following table is used to obtain the microalbumin to creatinine ratio.
Bilirubin • Creatinine g/L (mmol/L)
Specific Gravity • 0,1 (0,9) 0,5 (4,4) 1,0 (8,8) 2,0 (17,7) 3,0 (26,5)
Nitrite • 1 (10) * Normal
•
Microalbumin
mg/dL (mg/L)
Urobilinogen
3 (30)
Leukocytes •
High
8 (80) Abnormal
Abnormal
15 (150)
General details: * retest
• Proven performance and accuracy
• Strong colors
• No vitamin C interference
• 100 tests per pack It enables to:
• Storage temperature: 2 - 30 °C • Monitor the situation before proteinuria (high-level kidney disease) develops
• CE labelled • Measure a clinically meaningful result giving the microalbumin-to-creatinine ratio in a random urine sample
• Save time and avoid the hassle of a 24-hour urine collection
Advantages:
• No 24-hour urine collection required
• More sensitive and more specific results than with strips designed for general protein testing
Packing:
• 50 tests per pack
Order code:
• Urine-2AC
Layout 20140120
Layout 20140120
CL003 CL004
Number of keys 5 8
Dimension cm (L x W x H) 25 x 8 x 5 32 x 8 x 5
Weight 0,6 kg 0,8 kg
Order Code:
• CL003: Blood Cell Counter with 6 Windows
• CL004: Blood Cell Counter with 9 Windows
Layout 20140120
Layout 20140120
Suitable for mixing the contents of specimen tubes in the laboratory. We build the CL017 Dry Incubator to address the specific needs for biochemistry testing in
The instrument operates automatically upon pressing on the head of the vortex (press start function). clinical laboratories. We supply quality, convenience, and clarity.
Choose CYAN CL016 and get the following advantages: See more
• Automatic press start function Did you know that we used supercomputers to design a dry incubator with
• Variable speed control incredibly homogeneous temperature?
• Compact, robust, and durable
• Vibration free The homogeneous temperature across the heating block results in more accurate
• Fast measurements and improved CVs. Notice the difference!
• Quiet This precision engineering, with dual heating technology, lowers your energy
• High-quality motor for perfect performance consumption too.
Technical data:
• Silicon cup head Interactive Benefits
• Orbit of 4,5 mm The color touch screen displays the individual timers for With an individual timer for every tube, you will always
• Max. speed: 3200 rpm all 20 test tubes. You can program up to 10 specific timer know how long the incubation was. You have more
• Max. volume: 50 mL cycles. Each program has a unique name, up to three convenience to multitask, you work more accurately, and
• Max. weight: 60 g timer combinations (count-down or count-up), optional you have fewer hiccups. That is convenient.
• Head cup dimensions: 3,9 cm (Ø) buzzers, and the option to continue to the next timer You will save a lot of money by avoiding chronometers
• Overall dimensions: 5,5 x 11,3 x 8,1 cm (W x D x H) cycle automatically or not. purchases too.
• Gross weight: 0,90 kg You can select the programs per row or for the entire
• Power supply: 110/220 V - 50/60 Hz block.
Order code:
• CL016: Mini Vortex (110/220 V - 50/60 Hz)
Technical Specifications
The CL017 Dry incubator helps you to multitask and work more accurately.
Layout 20140120
Eyepiece specifications:
Accessories included:
• 2 filters (blue and green)
• Power adapter
Technical data: • Immersion oil
• Dust cover
Condenser Abbe condenser, NA = 1,25 • 4 objectives (4x , 10x, 40x, 100x)
Eyepiece Extra Wide Field: 10 x 20 mm and 10 x 18 mm • Black plastic hook
• 4 pieces of 10x eyepiece
Illumination S-LED 1W
Interpupillary distance 48 - 75 mm Order Code:
Coaxial coarse and fine adjustment • CM001N: CYANScope
Focusing moving range: 20 mm
fine division: 0,002 mm
Auxiliary products:
Objective Infinitive semi-plan objectives: 4x; 10x; 40x; 100x • CM001-S11A: Oil dark field condenser
Power supply 100-240 V - 50/60 Hz
Nose Quadruple nosepiece
Mechanical stage
Stage stage plate: 140 x 140 mm
moving range: 75 x 50 mm
Size 420 x 200 x 410 mm (L x W x H) - base: 270 x 200 mm (L x W), 8 kg
Viewing head Siedentopf binocular head; 30° inclined
Viewing height 392 mm
Layout 20140120
Layout 20140120
Single Channel - Fixed Volume - Pipettes PS00200 20 - 200 µL 1 µL 100 µL 0,80 % 0,30 %
20 µL 3,00 % 1,00 %
Code Volume Inaccuracy Imprecision 200 µL 0,60 % 0,15 %
PS0005 5 µL 1,30 % 1,20 % PS00500 50 - 200 µL 1 µL 100 µL 0,80 % 0,30 %
PS0010 10 µL 0,80 % 0,80 % 50 µL 1,00 % 0,40 %
PS0020 20 µL 0,60 % 0,50 %
1000 µL 0,60 % 0,20 %
PS0050 50 µL 0,50 % 0,30 %
PS01000 100 - 1000 µL 5 µL 500 µL 0,70 % 0,25 %
PS0100 100 µL 0,50 % 0,30 %
100 µL 2,00 % 0,70 %
PS0200 200 µL 0,40 % 0,20 %
5 mL 0,50 % 0,15 %
PS0500 500 µL 0,30 % 0,20 %
PS1000 1000 µL 0,30 % 0,20 % PS10000 1 - 5 mL 50 µL 2,5 mL 0,60 % 0,30 %
PS5000 5000 µL 0,30 % 0,15 % 1 mL 0,70 % 0,30 %
Extra:
• Pipette stand - order code: PSX
Layout 20140120
Layout 20140120
Layout 20140120
Layout 20140120
Disclaimer: this information is indicative and subject to change without prior notice. Use the documentation included with the products. If in
doubt, contact cypress@diagnostics.be