You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

HAP110003 ZZZ110001 ZZZ110007 ZZZ110009 V110004 MBD110002 MBD110008 MBD110005 MBD110010 PBA110006A/B NOTES:
WET FLARE KO WET FLARE DRY FLARE TANKAGE FLARE FLAME FRONT GENERATOR WET FLARE KO DRUM DRY FLARE KO DRUM CLOSED DRAIN DRUM TANKAGE FLARE KO DRUM DRAINAGE TRANSFER PUMP
DRUM HEATER 1. DELETED.
REMARKS : BY VENDOR REMARKS : BY VENDOR REMARKS : BY VENDOR REMARKS : BY VENDOR REMARKS : BY VENDOR SHELL : LTCS 3.2 mm CA SHELL : SS316/316L SHELL : SS316/316L SHELL : SS316/316L CASING : SS316/316L
DP [barg] : 10 INTERNALS : SS316/316L INTERNALS : SS316/316L INTERNALS : SS316/316L INTERNALS : SS316/316L IMPELLER : SS316/316L 2. REMOVABLE SPOOL PIECE TO ENSURE POSITIVE ISOLATION (NORMALLY DISCONNECTED).
DT [degC] : 290 (HOLD)/-45 DP [barg] : 10 DP [barg] : 10 DP [barg] : 10 DP [barg] : 10 DP [barg] : 15.5
A DT [degC] : 290 (HOLD)/-45 DT [degC] : 200/-170 DT [degC] : 100/-45 DT [degC] : 150/-170 DT [degC] : 100/-10
3. DELETED.
A
4. DELETED.
5. CONDENSATE POT TO SEPARATE DRAIN IN THE FLASH GAS.
ZZZ110012 ZZZ110011
6. SONIC TIP IS USED FOR WET AND DRY FLARE.
LP FUEL GAS BACK-UP PROPANE BOTTLE BACK-UP PROPANE BOTTLE
NOTE 8
FOR FFG FOR FLARE PURGE 7. FOR BUCK UP FUEL PURPOSE.
DG-520-12740-5001
BY VENDOR BY VENDOR 8. LP FUEL GAS IS USED FOR FLARE HEADER PURGE.
FROM MBD080002


LP FUEL GAS KNOCK OUT DRUM 9. NITROGEN IS USED FOR BACK-UP OF LP FUEL GAS.
NO
10. ON/OFF CONTROL.


NC NO To Add
N


IGNITION
□ □ □ □ □ □ □ □ □ □ □ □ □ □
B NOTE 9
NC PILOT NOTE M3 B
N
NOTE M4


PURGE
NOTE M2
TANKAGE FLARE HEADER FOR LNG

TANKAGE FLARE HEADER FOR LPG MBD110010


ZZZ110009


HC
NO
C C


NOTE 9
NC
N


DF


FROM COLD / DRY FLARE HEADER


DRY LIQUID DRAIN HEADER MSD NOTES:


To Add
M1. MATERIAL IS CHANGED AT THE UPSTREAM OF ISOLATION VALVE.


IGNITION
□ □ □ □ □


PILOT M2. MATERIAL IS CHANGED AT THE FLANGE WHICH IS LOCATED IN MIN 10 M FROM
NOTE M3
FLARE GAS LINE.
D Valves are added in PFD NOTE 2
NOTE M4 D


PURGE M3. MATERIAL OF PILOT LINE IN VENDOR PACKAGE IS SS.
NOTE M2 M4. MATERIAL IS CHANGE AT STRAINER.
M5. MATERIAL BRAKE SHALL BE AT HIGHEST POINT.
M6. MATERIAL IS CHANGED AT THE FLANGE WHICH IS LOCATED IN MIN 10 D (HOLD) FROM


CONNECTON POINT WITH FLASH GAS LINE.


HC ZZZ110007 LEGEND : MATERIAL CLASS BREAK
NOTE 6


CS : CARBON STEEL
E LTCS : LOW TEMPERATURE CARBON STEEL E


SS : STAINLESS STEEL
MBD110008 SDSS : SUPER DUPLEX STAINLESS STEEL
PWHT : POST WELD HEAT TREATMENT


DF DP : DESIGN PRESSURE
DT : DESIGN TEMPERATURE


CS (CA : 1.6 mm)


CS (CA : 3.2 mm)

CS (CA : 6.4 mm)



NOTE 2
F F


CS (CA : 1.6 mm) + PWHT


To Add
IGNITION


□ □ □ □ □ □ □ □ □ □ □ □ □ □ PILOT NOTE M3 CS (CA : 3.2 mm) + PWHT


NOTE M4 PURGE LTCS (CA : 1.6 mm)
NO


NOTE M2 LTCS (CA : 3.2 mm)

SS304 / SS304L
NOTE 9


NC
N SS316 / SS316L
G G


ZZZ110001 □ □ □ □ □ □ SS321 / SS321L
FROM WARM / WET FLARE HEADER MBD110002 NOTE 6


SDSS
FROM WET LIQUID DRAIN HEADER


H: OPEN Cu Ni
ELECTRIC L: STOP
LC CS GALVANIZED


HEATER

HAP110003


H NOTE 10
TC LY H


FLASH GAS
ZZZ110011


NOTE 5 NOTE M6
DG-020-12232-0001 LI
FROM MAF020003 BACK-UP PROPANE BOTTLE DWG NO. TITLE


AGR FLASH COLUMN FOR FLARE PURGE
REFERENCE DRAWINGS
NOTE 7


ATM
H: OPEN
I L: STOP I


01 15-SEP-2023 ISSUED FOR DESIGN R.IWAMA K.OOYAMA G.SAITO
MAINTENANCE DRAIN V110004 PC 00 24-MAR-2023 ISSUED FOR REVIEW R.IWAMA K.OOYAMA G.SAITO
TOP SIDES
FLAME FRONT REV DATE ISSUE PURPOSE PREP'D CHK'D APR'D
HULL DECK GENERATOR
N REVISIONS
H : STOP
LI LI

MBD110005
J IA J
HC
PBA110006A/B
HC WATER NOTE M5
DG-670-12740-5001
TO ABJ670001/2
MSD FOR FLARE SYSTEM - 1/2 (UNIT 110)
HC
CONDENSATE OFF-SPEC TANK
WATER NOTE M5
ZZZ110012
DG-570-12740-5001 BACK-UP PROPANE BOTTLE PCWBS SHEET SCALE
FOR FFG NONE 01 of 01 NONE
TO ABJ570001/2
COMPANY NAME COMPANY ENGINEER
SLOP TANK NOTE 7
K LP FUEL GAS UTM FLNG Limited Kellogg Brown & Root Limited K
DG-080-12232-0001 PROJECT NAME JOB CODE SIZE
FROM MBD080002 UTM FLNG FEED 0-9116-20 A1
LP FUEL GAS KNOCK OUT DRUM DWG NO. REV.
DG-110-12233-0001 01
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
NOTE:THIS PRINT IS OF A CONFIDENTIAL NATURE AND IS THE PROPERTY OF JGC CORPORATION,TOKYO,JAPAN AND SHALL NOT BE TRACED,PHOTOGRAPHD,PHOTOSTATED OR REPRODUCED IN ANY MANNER,NOR USED FOR ANY PURPOSE WHATSOEVER EXCEPT BY WRITTEN PERMISSION OF JGC CORPORATION.