You are on page 1of 4

122014.08.

21

18,579
8 7 6 5 4 3 2 1 825,579

REVISIONS REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

1A7 D 83162 CHANGE THERMISTOR DIGTAL CONNECTION TO 32 2014SEP30 W.SORAH G.DRAUGHN A 81554 ORIGINAL RELEASE 2013MAR05 R. REDMON J. BROWN
2B3 E 83335 ADDED DETAIL A, REVISED NOTE 7 FOR ALT. WIRING. 2014DEC12 R. REDMON H. XIANG 1A7 B 82529 REV'D I-R 302, REV'D 3TB, ADDED PTCR, 2014FEB28 R. REDMON H. XIANG
1A5 ADDED 10CR, ADDED NOTES 6 & 7 ON SHT 2-4.
C 83074 REVISED CONNECTIONS WITH INPUT 12 ON I-R302 2014AUG26 H. XIANG A. WILLIAMSON

575V UNITS
ONLY 6FU
0.1A
N/O L3 L3
C L2 L2 3FU
N/C L1 RED RED
D 6FU
L1 CON 2
WHT WHT
D
DIS1 LVM 0.1A 3
(OPTIONAL) 24V 1 PCB3 PCB2
1FU 1 1 12V 5 GRN GRN

P10
2LT BLK

J2
2 2

J1
24V
GND
L1
2 BLK
T1 110/120V
L3 1FU 5 PCB1 3 1
7
1Ma
J3 2
8 2Ma

P4
2

J4
2FU 9
200-460V 1 2 3 4 1 3 1Sa
UNITS MCB1 0V 10
0.5A BRN 1OL-1

GRN/YEL
BRN

BRN
BLU
GND

BLK
N/O
10CR-A
L3 11

P7
C L2 RFI 12
1LT
N/C L1 BLU MMS-1

P3
LVM GND 3CR-4
(OPTIONAL)
GND BLU 1TB-10
13 CPS
L3 3MTR 14 P

P8
3CR 15
L2
1TB-10 7SV 1TB-6 16
1 5 ES-2
17
3CR-7 2 6 18

P9
1TB-11 1TB-I 3 7 RSP
L1 5SV
1Mc 4 8
19
2M (REMOVE WIRE
IF LVM INSTALLED) 20 RST
C 1S RC2 ES-1 1PS C
21
1ATS P 22
1M 1TB-5
1OL 1 1 RED
1TB-2 1TB-3 1TB-4 LVM BLK
OPTION 2 1AVPT
T6 T4 T5 WHT
3
1CR 4
RED
BLK
T1 T2 T3 5 3APT
1TB-12 1M 2 6
WHT
1Sb RED
7
MTB L1 L2 L3 1Sc 8
BLK 4APT
1TB-12 2M 9
WHT
1Mb
10
MMS T1 T2 RC1 11

P5
T3
2Mb 12
1TB-13 1S 3
13 RED
1MTR
2CR BLK

P1
T1 T2 T3 14 6APT
15
WHT
T4 1TB-7
T6 T5 1TB-14 3SV 5 16
2MTR 17
SAR 7 18
B 22
B
4-20MA SYSTEM CWO 8
T3 T2 T1 PRESSURE (SEE MANUAL
23046360, FIELD INSTALLED) PORO 9 23
RED V+
24
+24 13
WHT (OPTIONAL) WHT
AI 53 SIGNAL 1TB-14 10
1
GND BLK 2CTT
COM 55 BLK CASE GND ES-3
2
3 WHT
L1 L2 L3 2ATT
37 3TB 1TB-14 4 BLK
305 1 N/O WHT

P6
+24 12 1 CTO
5
TO 306 2 C BLK 4ATT
I-R 302 ENABLE 18 2 1CR-A 2CR-A 1TB-1
307 3 N/C
6
DIS2

P2
TO 7
START 27 3 1L 2N 1TB-1 308 4 N/O 8
4
T/L3/93 PID ENABLE 33 4 PTCR CWO 309 5 C 9
5 10CR
S/L2/92 5 115V 310 6 N/C 10
01 6 7 8 9
R/L1/91 FAULT
03 6 3CR 0 0 0 0
THERMISTOR TO
DIGITAL 7 1TB-10 FOR NOTES AND LEGEND
PTC3
PTC2
PTC1

CONNECTION 10CR-B
(SEE NOTE 6) 32 8 SEE OPERATORS MANUAL.
SEE NOTE 7
24486250 REV E
A A
DO NOT SCALE DRAWING
402,81 615,81 825,81

STANDARD TOLERANCES WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO
ALL DIMENSIONS ARE IN ASME Y14.5M - 1994
THIRD ANGLE PROJECTION
PROPRIETARY NOTICE
NOTES : MILLIMETERS
[INCHES (IF SHOWN)] CAD GENERATED DRAWING,
DRAWN

R. REDMOND
DATE

2013MAR05
R

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED NAME

DECAL, WIRING SCHEMATIC (Xe),


CHECKED DATE

1. DECAL MUST CONFORM TO THE LATEST REVISION OF I-R SPECIFICATION 92-8.95 UNSPECIFIED TOLERANCES: GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE UNLESS OTHERWISE SPECIFIED:
B. WARREN /J.M. 2013MAY22
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY APPROVED DATE

VFD, SD, AIR COOLED


- REMOVE ALL BURRS AND SHARP CORNERS
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY - WELD SYMBOLS TO BE IN ACCORDANCE J. BROWN 2013MAY22
WHOLE : 1 THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
ONE PLACE (.X) : 0.5 WITH ANSI/AWS A2.4 DRAWING TYPE
DECAL, WIRING SCHEMATIC (Xe), VFD, SD, AIR COOLED

THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS SIZE ESTIMATED WEIGHT DWG NO. REVISION
TWO PLACE (.XX) : 0.25 Detail Drawing
A1 24486250 E
24486250

EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET (KG UNLESS OTHERWISE SPECIFIED)
ANGLES (.X) : 1 INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO COPYRIGHT @ 2014 NOMENCLATURE
0.0 kilogram
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL Ingersoll Rand PART NO.

18,18
Ingersoll-Rand Industrial Technologies 402,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. ALL RIGHTS RESERVED SCALE MODEL SSR 250-500HP 2STG SHEET 1 OF 4
For Internal Use:24486250|PART|E.0|Randy Redmond|12-Dec-14 09:50:36 AM|Open

8 7 6 5 4 3 2 1
15-Dec-2014 11:21:18 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1
122014.08.21

18,579
8 7 6 5 4 3 2 1 826,579

LEGEND LEGEND
D D
ABBREV DESCRIPTION ABBREV DESCRIPTION
PE EARTH LEAD, MAIN TERMINAL 2ATT SENSOR, TEMPERATURE - AIREND DISCHARGE
GND EARTH/GROUND 2CTT SENSOR, TEMPERATURE - INJECTED COOLANT
DIS1 MAIN DISCONNECT (CUSTOMER SUPPLIED) 4ATT SENSOR, TEMPERATURE - PACKAGE DISCHARGE
L1-L3 MAIN TERMINALS IPS SWITCH, INTERSTAGE PRESSURE (TWO STAGE UNIT ONLY)
1FU-3FU CONTROL FUSE (3FU MUST BE A FAST ACTING TYPE BBS FUSE) CPS SWITCH, COOLANT DELTA PRESSURE
T1 TRANSFORMER, 110-1-50 OR 120-1-60, 24V 1TB,3TB TERMINALS
TRANSFORMER/FUSE SIZE: P7 SERVICE TOOL PORT
TI(VA) 1FU(A) 2FU(A) 3FU(A)
280 1.8 2.0 5.0 P8 ETHERNET
380 2.5 3.2 5.0 P9 EXTERNAL COMMUNICATIONS
580 3.5 5.0 5.0
625 3.5 5.0 8.0
1M MAIN CONTACTOR
1Ma-c MAIN CONTACTOR AUXILIARY CONTACTS OPTIONS
2M DELTA CONTACTOR LMV LINE VOLTAGE MONITOR
2Ma-d DELTA CONTACTOR AUXILIARY CONTACTS MCB1 CIRCUIT BREAKER
1S STAR CONTACTOR PORO HORN, POWER OUTAGE RESTART
1Sa-c STAR CONTACTOR AUXILIARY CONTACTS
C C
1MTR MAIN DRIVE MOTOR
2MTR FAN MOTOR
3MTR STEPPER MOTOR LEGEND
1OL MAIN MOTOR OVERLOAD RELAY
MMS FAN MANUAL MOTOR STARTER
ABBREV DESCRIPTION
RFI RFI FILTER BLK BLACK
1LT LAMP, POWER ON - BACKPANEL BLU BLUE
2LT LAMP, POWER ON - INSTRUMENT PANEL GRN GREEN
PCB1 PRINTED CIRCUIT BOARD, POWER SUPPLY RED RED
PCB2 PRINTED CIRCUIT BOARD, STEPPER LIMIT WHT WHITE 1TB-14

PCB3 PRINTED CIRCUIT BOARD, STEPPER LIMIT ADAPTER YEL YELLOW TO


ES EMERGENCY STOP BRN BROWN 1TB-1

GRN/YEL GREEN/YELLOW TO
3SV SOLENOID VALVE, BLOWDOWN 1L 2N 1TB-1
5
5SV SOLENOID VALVE, COOLANT STOP (NOT REQUIRED ON UNITS WITH OIL PUMP) PTCR
6 10CR
7SV SOLENOID VALVE, PRESSURE RELIEF (REMOTE COOLED UNIT ONLY)
3 4
1ATS SWITCH, HIGH AIR TEMPERATURE 0 0
RC1-2 ARC SUPPRESSORS
B CON CONTROLLER B
CTO COMMON TRIP OUTPUT DETAIL A
PTC (SEE NOTE 7)
CWO COMMON WARNING OUTPUT
RSP REMOTE STOP NOTES:
RST REMOTE START
1. MAIN DISCONNECT AND BRANCH CIRCUIT PROTECTION TO BE PROVIDED
STOPPED IN AUTO RESTART BY CUSTOMER.
SAR USE WITH CUSTOMER SUPPLIED RELAY HAVING COIL RATING OF
110VAC-50HZ, 120VAC-60HZ, 250MA MAXIMUM 2. DASHED LINES REPRESENT WIRING BY CUSTOMER.
1AVPT TRANSDUCER, PRESSURE - INLET VACUUM 3. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY INGERSOLL-RAND,
3APT TRANSDUCER, PRESSURE - SEPARATOR TANK WET SIDE IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE DONE IN
4APT TRANSDUCER, PRESSURE - PACKAGE DISCHARGE ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA PLATE,
NATIONAL AND LOCAL ELECTRICAL CODES.
6APT TRANSDUCER, PRESSURE - SEPARATOR TANK DRY SIDE
1CR START RELAY 4. IPS IS REPLACED WITH A JUMPER WIRE FROM 1TB-3 TO 1TB-4 ON UNITS
2CR LOAD RELAY NOT REQUIRING AN INTERSTAGE PRESSURE SWITCH.
3CR DRIVE FAULT RELAY 5. USE SEMICONDUCTOR FAST-BLOW FUSES (SEE INSTRUCTION MANUAL).
10CR CONTROL RELAY
PTCR PTC MONITOR RELAY 6. SET PARAMETER 1-90 "MOTOR THERMAL PROTECTION" TO THERMISTOR TRIP (2).
SET PARAMETER 1-93 "THERMISTOR SOURCE" TO DIGITAL INPUT 32 (5).
I-R302 VARIABLE FREQUENCY DRIVE
A DIS2 FUSED DISCONNECT FOR V.F.DRIVE (CUSTOMER SUPPLIED OR I-R OPTIONAL). 7. PTC MONITOR RELAY ONLY FOR 300 HP AND ABOVE MOTORS WITH PTC'S A
SEE NOTE 5. (REFERENCE FOR BALDOR MOTORS ONLY).
MTB MOTOR TERMINAL BLOCK SEE DETAIL "A" FOR ALTERNATE WIRING BASED OFF MOTOR WIRING.

636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DECAL, WIRING SCHEMATIC (Xe), DECAL, WIRING SCHEMATIC (Xe), VFD, SD, AIR COOLED

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
VFD, SD, AIR COOLED
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
SIZE DWG NO. REVISION

24486250 E
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE

A1
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
PART NO.
24486250

THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN


THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 2 OF 4

8 7 6 5 4 3 2 1
15-Dec-2014 11:21:18 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1
122014.08.21

18,579
8 7 6 5 4 3 2 1 826,579

SPANISH
IDENTIFICACION IDENTIFICACION
D D
ABBREV DESCRIPCION ABBREV DESCRIPCION
PE CONEXION DE TIERRA, TERMINAL PRINCIPAL 2ATT SENSOR DE TEMPERATURA - DESCARGA DE UNIDAD DE AIRE
GND TIERRA 2CTT SENSOR DE TEMPERATURA - LUBRICANTE DE INYECCION
DIS1 DESCONEXION PRINCIPAL (SUMINISTRADA POR EL CLIENTE) 4ATT SENSOR DE TEMPERATURA - DESCARGA DEL PAQUETE
L1-L3 BORNES DE ALIMENTACION DE FUERZA IPS INTERRUPTOR DE PRESION ENTRE ETAPAS
(UNICAMENTE UNIDADES DE DOS ETAPAS)
1FU-3FU FUSIBLES DE CONTROL - 3FU DEBERA SER UN FUSIBLE BBS DE ACCION RAPIDA.
T1 TRANSFORMADOR, 110-1-50 OR 120-1-60, 24V CPS INTERRUPTOR, LUBRICANTE VARIACION DE PRESIION
CAPACIDADES DE TRANSFORMADOR/FUSIBLES: 1TB,3TB TERMINALES
TI(VA) 1FU(A) 2FU(A) 3FU(A) P7 SERVICIO DE HERRAMIENTAS PUERTO
280 1.8 2.0 5.0
380 2.5 3.2 5.0 P8 ETHERNET
580 3.5 5.0 5.0 P9 COMUNICACIONES EXTERNAS
625 3.5 5.0 8.0
1M CONTACTOR DE OPERACION/ARRANQUE
1Ma-c CONTACTORS AUXILIARES DEL CONTACTOR DE OPERACION/ARRANQUE
2M CONTACTOR DE OPERACION
2Ma-d CONTACTORS AUXILIARES DEL CONTACTOR DE OPERACION OPCIONS
1S CONTACTOR DE ARRANQUE LVM MONITOR DE VOLTAE
1Sa-c CONTACTORS AUXILIARES DEL CONTACTOR DE ARRANQUE MCB1 INTERRUPTORES DEL CIRCUITO
C C
1MTR MOTOR DEL COMPRESOR PORO SIRENA DE ARRANQUE POR
INTERRUPCION/FALLO DE POTENCIA
2MTR MOTOR DEL VENTILADOR
3MTR MOTOR DEL PASO
1OL RELE TERMICO DEL MOTOR
MMS ARRANQUE MANUAL DEL MOTOR DEL VENTILADOR
RFI FILTRO RFI IDENTIFICACION
1LT LAMPARA, CORRIENTE CONECTADA - PANEL POSTERIOR
ABBREV DESCRIPCION
2LT LAMPARA, CORRIENTE CONECTADA - PANEL DE INSTRUMENTOS
PCB1 TARJETA DE CIRCUITOS IMPRESOS, ALIMENTACION DE CORRIENTE BLK NEGRO
PCB2 TARJETA DE CIRCUITOS IMPRESOS, LIMITADOR DE PASOS BLU AZUL
PCB3 TARJETA DE CIRCUITOS IMPRESOS, LIMITADOR DE PASOS ADAPTADOR GRN VERDE
ES PARADA DE EMERGENCIA RED ROJO
3SV SOLENOIDES DE EVACUACION WHT BLANCO
5SV SOLENOIDE DE CORTE DE REFRIGERANTE YEL AMARILLO
(NO SE REQUIERE EN UNIDADES CON BOMBA DE LUBRICACION) BRN MARRON
7SV SOLENOIDE DE ALIVIO DE PRESION GRN/YEL VERDE/AMARILLO
(UNIDADES CON ENFRIADORES REMOTOS, UNICAMENTE)
1ATS INTERRUPTOR POR ALTA TEMPERATURA DE AIRE
B B
RC1-2 SUPRESORES DEL ARCO
CON CONTROLADOR
CTO SALIDA DE ZANCADILLA COMÚN
CWO SALIDA DE ADVERTENCIA COMÚN NOTAS :
SALIDA DE AVISO REMOTA, SUMINISTRO DEL CLIENTE
CALIBRANDO EL ENBOBINADO DE 1. EL INTERRUPTOR PRINCIPAL Y LA PROTECCION DEL CIRCUITO SERAN
SAR SUMINISTRADOS POR EL CLIENTE.
110 VAC 50HZ, 120 VAC 60HZ, CON UN MAXIMO DE 250 MA

RSP PARADA REMOTA 2. LINEAS DISCONTINUAS REPRESENTAN CABLEADO SUMINISTRADO POR EL CLIENTE.
RST ARRANQUE REMOTO 3. LA SELECION DE COMPONENTES ELECTRICIOS NO SUMINISTRADOS POR INGERSOLL-
1AVPT TRANSDUCTOR DE PRESION - VACIO DE ADMISION RAND ES RESPONSABILIDAD DEL CLIENTE Y DEBERA SER HECHA DE ACUERDO CON
3APT TRANSDUCTOR DE PRESION - TANQUE SEPARADOR LADO HUMEDO DE PLACA DEL COMPRESOR, N.E.C. Y LOS CODIGOS ELECTRICOS LOCALES.
4APT TRANSDUCTOR DE PRESION - DESCARGA DE LA UNIDAD 4. EL IPS ES REEMPLAZADO POR UN ALAMBRE CONECTOR DESDE 1TB-3 A 1TB-4 LAS
6APT TRANSDUCTOR DE PRESION - TANQUE SEPARADOR LADO SECO UNIDADE QUE NO REQUIEREN UN INTERRUPTOR DE PRESION ENTRE ETAPAS.
1CR RELÉ DE ARRANQUE
5. UTILIZAR FUSIBLES SEMICONDUCTORES DE RAPIDA-ACTUACION (VER EL MANUAL DE
2CR RELÉ DE CARGA INSTRUCCIONES).
3CR RELÉ DE FALLA DEL VARIADOR DE FRECUENCIA
10CR RELÉ DE CONTROL 6. AJUSTE EL PARÁMETRO 1-90 "PROTECCIÓN TÉRMICA DEL MOTOR" DEL TERMISTOR (2).
AJUSTE EL PARÁMETRO 1-93 "FUENTE TERMISTOR" A DIGITAL ENTRADA 32 (5).
PTCR PTC MONITOR RELÉ
A A
I-R302 VARIADOR DE FRECUENCIA 7. PTC RELÉ MONITOR SÓLO PARA 300 CV Y MAYOR MOTORES CON PTC'S
DIS2 CONEXION DEL FUSIBLES PARA EL VARIADOR DE FRECUENCIA (REFERENCIA PARA BALDOR ELECTRIC MOTORS SÓLO).
(POR EL CLIENTE O I-R OPCIONAL). VER NOTA 4. VER DETALLE PARA UN CABLEADO ALTERNA BASADA OFF CALEADO DEL MOTOR.
MTB TERMINALES DEL MOTOR 636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DECAL, WIRING SCHEMATIC (Xe), DECAL, WIRING SCHEMATIC (Xe), VFD, SD, AIR COOLED

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
VFD, SD, AIR COOLED
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
SIZE DWG NO. REVISION

24486250 E
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE

A1
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
PART NO.
24486250

THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN


THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 3 OF 4

8 7 6 5 4 3 2 1
15-Dec-2014 11:21:18 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1
122014.08.21

18,579
8 7 6 5 4 3 2 1 826,579

PORTUGUESE
LEGENDA LEGENDA
D D
ABBREV DESCRIPTION
ABBREV DESCRIPTION
2ATT SENSOR, TEMPERATURA - DESCARGA UNIDADE
PE CABO DE TERRA, TERMINAL DE REDE 2CTT SENSOR, TEMPERATURA - INJECAO LUBRIFICANTE
GND TERRA 4ATT SENSOR, TEMPERATURA - DESCARGA COMPRESSOR
DIS1 INTERRUPTOR PRINCIPAL (FORNECIDO PELO CLIENTE) IPS PRESSOSTATO INTERESTAGIAL
L1-L3 TERMINAIS PRINCIPAIS (SOMENTE NAS UNIDADES DE DOIS ESTAGIOS)
1FU-3FU FUSIVEL DE CONTROLE - O FUSIVEL 3FU DEVERA SER TIPO BBS DE ACAO RAPIDA CPS INTERRUPTOR, DELTA-P LUBRIFICANTE
T1 TRANSFORMADOR, 110-1-50 OR 120-1-60, 24V 1TB,3TB REGUA DE BORNES
TAMANHO TRANSFORMADOR/FUSIVEL: P7 SERVIÇO DE FERRAMENTA PORT
TI(VA) 1FU(A) 2FU(A) 3FU(A)
280 1.8 2.0 5.0 P8 ETHERNET
380 2.5 3.2 5.0 P9 COMUNICAÇÕES EXTERNAS
580 3.5 5.0 5.0
625 3.5 5.0 8.0
1M CONTATOR OPERAR/PARTIR
1Ma-c CONTATOS AUXILIARES CONTATOR OPERAR/PARTIR OPCOS
2M CONTATOR OPERAR
LVM MONITOR LINHA DE VOLTAGEM
2Ma-d CONTATOS AUXILIARES CONTATOR OPERAR
MCB1 DISJUNTORES
1S CONTATOR PARTIR
PORO BUZINA, NOVA PARTIDA
C 1Sa-c CONTATOS AUXILIARES CONTATOR PARTIR C
1MTR MOTOR DO COMPRESSOR
2MTR MOTOR DO VENTILADOR
3MTR MOTOR DE PASSOS
1OL TERMICO DE PROTECAO DO MOTOR
LEGENDA
MMS ARRANCADOR MANUAL DO MOTOR DE VENTILADOR
ABBREV DESCRIPTION
RFI RELE DE RFI
BLK PRETO
1LT LUZ, CORRENTE LIGADA - PAINEL TRASEIRO
BLU AZUL
2LT LUZ, CORRENTE LIGADA - PAINEL DE INSTRUMENTOS
GRN VERDE
PCB1 PLACA DE CIRCUITO, ABASTECIMENTO DE CORRENTE
RED VERMELHO
PCB2 PLACA DE CIRCUITO, PASSO LIMITADORA
WHT BRANCO
PCB3 PLACA DE CIRCUITO, PASSO LIMITADORA ADAPTADOR
YEL AMARELO
ES PARADA DE EMERGENCIA
BRN MARROM
3SV SOLENOIDE DE ALIVIO
GRN/YEL VERDE/AMARELO
5SV SOLENOIDE BLOQUEIO OLEO
(NAO NECESSARIO NAS UNIDADES COM BOMBA DE OLEO)
7SV SOLENOIDE ALIVIO PRESSAO
(SOMENTE NAS UNIDADES COM RESFRIADOR REMOTO)
1ATS CONTATO ALTA TEMPERATURA DO AR
B B
RC1-2 SUPRESSORES DE ARCO
CON CONTROLADOR
NOTAS :
CTO SAÍDA TRIP COMUM
CWO SAÍDA AVISO COMUM 1. CHAVE INTERRUPTORA PRINCIPAL E RAMAL DO CIRCUITO DE PROTECAO, A SEREM
SAR PARTIDA-PARADA AUTOMATICA FORNECIDOS PELO CLIENTE.
RSP PARADA REMOTA 2. LINHAS TRACEJADAS REPRESENTAM FIACAO ELETRICA DO CLIENTE.
RST PARTIDA REMOTA
1AVPT TRANSDUTOR, PRESSAO - VACUO ADMISSAO 3. DIMENSIONAMENTO DOS COMPONENTES ELETRICOS, NAO E FORNECIDO PELA
INGERSOLL-RAND, E DE RESPONSABILIDADE DO CLIENTE E DEVE SER
3APT TRANSDUTOR, PRESSAO - PRESSAO TANQUE SEPARADOR UMIDO EXECUTADO DE ACORDO COM AS INFORMACOES DE PLACA DO COMPRESSOR E
4APT TRANSDUTOR, PRESSAO - PRESSAO DESCARGA UNIDADE COM AS NORMAS ELETRICAS LOCAIS E NACIONAIS.
6APT TRANSDUTOR, PRESSAO - PRESSAO TANQUE SEPARADOR SECO
4. IPS E SUBSTITUIDO POR UM JUMPER ENTRE 1TB-3 E 1TB-4 NOS COMPRESSORES
1CR RELÉ DE PARTIDA SEM PRESSOSTATO INTERESTAGIAL.
2CR RELÉ DE CARGA
3CR RELÉ DE PROTECAO DO MOTOR 5. USE FUSIVEIS SEMICONDUTORES DE ACAO RAPIDA (VEJA MANUAL DE INSTRUCOES).
10CR CONTROLO RELÉ 6. AJUSTE O PARÂMETRO 1-90 (PROTECÇÃO TÉRMICA DO MOTOR) A VIAGEM DO TERMISTOR (2).
PTCR PTC RELÉ DO MONITOR AJUSTE O PARÂMETRO 1-93 (TERMISTOR FONTE) DIGITAL ENTRADA 32 (5).
I-R302 MOTOR COM VARIADOR DE FREQUENCIA
7. PTC RELÉ DO MONITOR SOMENTE PARA 300 HP E ACIMA MOTORES COM PTC'S
A DIS2 DISJUNTOR DO VARIADOR DE FREQUENCIA DO MOTOR (REFERÊNCIA PARA BALDOR MOTORS SÓ). A
(FORNECIMENTO DO CLIENTE OU I-R OPCIONAL). VEJA NOTA 5 VEJA DETALHES "A" PARA A FIAÇÃO ALTERNATIVAS BASEADO FORA FIAÇÃO DO MOTOR.
MTB TERMINAIS ELETRICOS DO MOTOR

636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DECAL, WIRING SCHEMATIC (Xe), DECAL, WIRING SCHEMATIC (Xe), VFD, SD, AIR COOLED

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
VFD, SD, AIR COOLED
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
SIZE DWG NO. REVISION

24486250 E
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE

A1
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
PART NO.
24486250

THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN


THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 4 OF 4

8 7 6 5 4 3 2 1
15-Dec-2014 11:21:18 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1