Hydraulic cylinder
mill type
CDL2 type
▶ Series L2
▶ Component series 2X
▶ 2 pressure ranges:
– Nominal pressure 160 bar
– Nominal pressure 250 bar
CDL2MP5_d
Features Contents
Ordering codes
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
CD L2 / / / 2X / B 1 1 C U W
01 Differential cylinder CD
02 Series L2
Types of mounting
03 Without M00 1)
Self-aligning clevis at base MP5
Round flange at head MF3 2)
Trunnion mounting MT4 2; 3)
05 Piston rod Ø (ØMM) at a nominal pressure of 160 bar: 14, 18, 22, 28, 36, 45, 56 and 70 mm, see page 6
Piston rod Ø (ØMM) at a nominal pressure of 250 bar: 25, 32, 40, 50, 63, 80, 100 and 125 mm, see page 6
Design principle
07 Head and base screwed in C 1)
Head screwed in, base welded D 4)
Ordering codes
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
CD L2 / / / 2X / B 1 1 C U W
Order example:
CDL2MT4/100/56/200D2X/B11CHUMWWWWYWWW
LY=20 XV=245
CDL2MF3/80/45/100D2X/B11CHUMWWWWWWWW
1) Only piston Ø 25 … 32 mm
2) Only piston Ø 25 … 125 mm
3) Trunnion mounting position freely selectable. Always specify
the dimension "XV/XU" in mm in the plain text when ordering
(see order example)
4) Only piston Ø 40 … 200 mm
5) Only "MP5" / "MT4"
Ordering codes
01 02 03 04 05 06 07 08
Z W W W W
01 Without W
02 Without W
03 Without W
Technical data
(For applications outside these values, please consult us!)
General
Installation position Any
Ambient temperature range See page 29
Priming See page 33
Hydraulic
Nominal pressure 1) ▶ ØMM: 14, 18, 22, 28, 36, 45, bar 160
65 and 70 mm
▶ ØMM: 25, 32, 40, 50, 63, 80, bar 250
100 and 125 mm
Minimum operating pressure 2) (without load) bar 10
Static test pressure ▶ 160 bar bar 240
▶ 250 bar bar 375
Hydraulic fluid See table below
Hydraulic fluid temperature range °C See page 29
Viscosity range mm2/s 12 … 380
Viscosity at operating temperature (recommended) mm2/s 20 … 100
Stroke velocity m/s 0.5
Maximum admissible degree of contamination of the Class 20/18/15
hydraulic fluid, cleanliness class according to ISO 4406 (c)
Technical data
(For applications outside these values, please consult us!)
F1 A3 A1
F3 qV3 qV1
Technical data
(For applications outside these values, please consult us!)
"MF3" (see page 12, 13) "MT4" (see page 14, 15)
Dimensions: "M00"
(dimensions in mm)
ØAL 25 ... 32 mm
Y PJ + X* 1)
EE EE
SF
X1
ØD
KK
KK
ØMM
W
A AB
ZB + X* 1)
ØAL ØMM
at a nominal pressure of KK A AB SF W ØD Y PJ EE X1 ZB
+3/-1 ±1
160 bar 250 bar
25 14 – M10 26 21 12 10 31 44 27 G1/8 24.5 105
32 18 – M12 28 25 15 11 40 48 32 G1/4 33.5 117
1) X* = stroke length
Dimensions: "MP5"
(dimensions in mm)
ØAL 25 ... 32 mm
Y PJ + X* 1)
Piston rod end "E"
EE EE EN
EU
„A“
ØCN
10°
X1
ØD
10°
ØMM
KK
W „A-A“
SF A LT
XO + X* 1)
Piston rod end "L"
„A“
„A“
MS LT
XF + X* 1)
„A“
4°
X3
ØMM
ØD
KK
4°
SF A W LT MS EP
XO + X* 1)
EX
Piston rod end "F"
3)
„A“ „A-A“
„B“
ØCX 2)
4°
4°
EF LF EP
WA EX
YA
XF + X* 1) „B-B“
„B“
Dimensions: "MP5"
(dimensions in mm)
ØAL ØMM KK A SF W WA ØD Y YA PJ XO XF
at a nominal pressure of
160 bar 250 bar
25 14 – M10 26 12 10 – 31 44 – 27 132 158
32 18 – M12 28 15 11 – 40 48 – 32 149 180
22 – M16x1.5 22 17 13 43 50 60 90 51 141 170
40
– 25 M20x1.5 28 19 15 41 52 62 88 54 147 173
28 – M20x1.5 28 22 13 50 60 62 99 58 158 195
50
– 32 M27x2 36 27 15 52 62 64 101 65 167 204
36 – M27x2 36 28 14 62 75 68 116 70 183 230
63
– 40 M33x2 45 32 17 64 78 71 118 72 192 239
45 – M33x2 45 36 16 76 95 84 144 77 209 269
80
– 50 M42x2 56 41 19 74 100 84 139 81 222 277
56 – M42x2 56 46 18 88 120 90 160 85 228 298
100
– 63 M48x2 63 50 19 90 125 91 162 93 256 327
70 – M48x2 63 60 20 106 150 99 185 94 260 346
125
– 80 M64x3 85 65 22 112 160 105 195 113 307 397
160 – 100 M80x3 95 85 30 118 200 124 212 120 390 478
200 – 125 M100x3 112 110 35 143 245 139 247 124 434 542
1) X* = stroke length
2) Related bolt Ø j6
3) Grease nipple, cone head form A according to DIN 71412
4) min.
Dimensions: "MF3"
(dimensions in mm)
ØAL 25 ... 32 mm
ØF
B
X1
90°
ØD
ØB
KK
KK
SF
VD AB ØFC
WC NF ØUC
A
ZB+ X* 1)
„A“ X2
ØD
ØB
KK
ØMM
SF
A
VD
WC NF
ZB+ X* 1)
„A“
Dimensions: "MF3"
(dimensions in mm)
ØAL ØMM KK A AB SF ØB VD WC NF ØD Y PJ
at a nominal pressure of ±0.3
160 bar 250 bar
25 14 – M10 26 21 12 32 6 16 12 31 44 27
32 18 – M12 28 25 15 40 6 17 12 40 48 32
22 – M16x1.5 22 – 17 50 7 20 14 50 60 51
40
– 25 M20x1.5 28 – 19 52 7 22 17 52 72 53
28 – M20x1.5 28 – 22 60 7 20 16 60 62 58
50
– 32 M27x2 36 – 27 62 7 22 19 62 77 59
36 – M27x2 36 – 28 75 7 21 20 75 68 72
63
– 40 M33x2 45 – 32 78 7 24 22 78 86 71
45 – M33x2 45 – 36 93 7 23 25 95 84 81
80
– 50 M42x2 56 – 41 100 10 29 28 100 97 75
56 – M42x2 56 – 46 120 8 26 25 120 90 88
100
– 63 M48x2 63 – 50 125 2) 11 30 32 125 106 89
70 – M48x2 63 – 60 150 2) 9 29 32 150 99 98
125
– 80 M64x3 85 – 65 160 2) 17 39 35 160 119 102
1) X* = stroke length
2) Tolerance: ±0.5
Dimensions: "MT4"
(dimensions in mm)
ØAL 25 ... 32 mm
Y PJ + X* 1; 2)
EE EE
r
X1
UV 4)
ØD
KK
KK
ØTD
ØMM
W
SF A BD AB TL TM TL
XV 3)
ZB + X* 1; 2)
X2
ØMM
UV 4)
KK
ØD
ØTD
SF A W BD TL TM TL
XV 3)
ZB + X* 1; 2)
„A“ 5)
4°
ØCX
4°
EF WA
YA EP
XU 3) EX
ZV + X* 1; 2)
„A“ „A-A“
Dimensions: "MT4"
(dimensions in mm)
ØAL ØMM KK A AB SF W WA ØD Y YA PJ X* 2) XV XU
at a nominal pressure of
25 14 – M10 26 21 12 10 – 33 44 – 27 21 68 47+X* – –
32 18 – M12 28 25 15 11 – 40 48 – 32 28 78 50+X* – –
22 – M16x1.5 22 – 17 13 43 50 60 90 51 23 94 71+X* 124 101+X*
40
– 25 M20x1.5 28 – 19 15 41 52 62 88 53 60 112 52+X* 138 78+X*
28 – M20x1.5 28 – 22 13 50 60 62 99 58 32 104 72+X* 141 109+X*
50
– 32 M27x2 36 – 27 15 52 62 64 101 62 66 121 55+X* 158 92+X*
36 – M27x2 36 – 28 14 62 75 68 116 72 37 119 82+X* 167 130+X*
63
– 40 M33x2 45 – 32 17 64 78 71 118 71 78 135 57+X* 182 104+X*
45 – M33x2 45 – 36 16 76 95 84 144 81 51 144 93+X* 204 153+X*
80
– 50 M42x2 56 – 41 19 74 100 84 139 78 91 157 66+X* 212 121+X*
56 – M42x2 56 – 46 18 88 120 90 160 88 69 162 93+X* 232 163+X*
100
– 63 M48x2 63 – 50 19 90 125 91 162 90 115 180 65+X* 251 136+X*
70 – M48x2 63 – 60 20 106 150 99 185 98 85 183 98+X* 269 184+X*
125
– 80 M64x3 85 – 65 22 112 160 105 195 102 135 208 73+X* 298 163+X*
1) X* = stroke length
2) Observe the min. stroke length "X* min"!
3) Long trunnion mounting freely selectable. Always specify the
dimensions "XV" / "XU" in mm in the plain text when ordering.
4) The specified dimensions are maximum values
5) Grease nipple, cone head form A according to DIN 71412
1)
ØCK
ØS
ØHB
LE
FL
1
FG FO CO RF
KC
RG UK
UX
ØAL = piston Ø
ØMM = piston rod Ø Notice:
1)Related bolt Ø m6 Geometry and dimensions may differ depending on the
(bolt and bolt lock are included in the scope of delivery and not manufacturer. In case of combination with other mounting
mounted upon delivery) elements, the usability must be checked.
The clevis brackets are suitable for attachment in case of
2) 2 washers for mounting required
type of mounting "MP5" and at the swivel head.
▶ for CLCA 10: Washer DIN 988 10x16x0.5
Material no. R900061310
▶ for CLCA 12: Washer DIN 988 12x18x1
Material no. R900006948
3) On request
4) m = mass of clevis bracket in kg
ØCK
ØS
LE
ØHB
FL
1
TB RC
UH UR
ØAL = piston Ø
ØMM = piston rod Ø Notice:
1) Related bolt Ø m6 Geometry and dimensions may differ depending on the
(bolt and bolt lock are included in the scope of delivery and manufacturer. In case of combination with other mounting
not mounted upon delivery) elements, the usability must be checked.
The clevis brackets are suitable for attachment in case of
2) 2 washers for mounting required
type of mounting "MP5" and at the swivel head.
▶ for CLCD 10: Washer DIN 988 10x16x0.5
Material no. R900061310
▶ for CLCD 12: Washer DIN 988 12x18x1
Material no. R900006948
3) On request
4) m = mass of clevis bracket in kg
"A" "A"
TN TN
1)
ØCR ØCR 1)
ØHB ØHB
FN
FN
FK
FK
L2
L2
KC
KC
CO CO
TH TH
UL UL
L3 x 45°
2)
"A"
FS
NH
ØAL = piston Ø
1) Grease nipple, cone head form A according to DIN 71412 Notice:
2) Trunnion mounting contact surface (inside) Geometry and dimensions may differ depending on the
manufacturer. In case of combination with other mounting
3) Bearing blocks are always supplied in pairs
elements, the usability must be checked.
4) Nominal force applies to applications in pairs
The trunnion mounting bearing blocks are suitable for
5) m = mass of trunnion mounting bearing block in kg attachment in case of type of mounting "MT4".
(specified per pair) All graphical representations are examples.
ISO 8132
ØAL = piston Ø
ØMM = piston rod Ø Notice:
1) Grease nipple, cone head form A according to DIN 71412 Geometry and dimensions may differ depending on the
manufacturer. In case of combination with other mounting
2) Related bolt Ø m6
elements, the usability must be checked.
3) MA = tightening torque
The swivel head must always be screwed against the shoulder
of the piston rod. Afterwards, the clamping screws must be
tightened with the specified tightening torque.
4) m = mass of swivel head in kg
5) C0 = static load rating of the swivel head
6) Fadm= maximum admissible load on the swivel head during
oscillatory or alternating loads
ISO 12240-4
EN
EU C
ØCN
10
°
LF
°
10
CP
BA
KW
SF KK
ØAL = piston Ø
ØMM = piston rod Ø Notice:
1) m = mass of swivel head in kg Geometry and dimensions may differ depending on the
manufacturer. In case of combination with other mounting
2) C0 = static load rating of the swivel head in kN
elements, the usability must be checked.
3) Fadm = maximum admissible load on the swivel head during
oscillatory or alternating loads
Buckling
= =
Re Yield strength of the piston rod material
L
L
L
L
L
LK = 0,7 L LK = L LK = 2 L
Buckling
(dimensions in mm)
Installation position
0° 45° 90°
1)
1)
1)
Buckling
(dimensions in mm)
Installation position
0° 45° 90°
1)
1)
1)
Buckling
(dimensions in mm)
Installation position
0° 45° 90°
2)
2)
2)
Working conditions
Hydraulic fluid Seal versions
Hydraulic fluid
temperature range "M" "V"
HL, HLP –20 °C … +80 °C ++ ++
HFDR –15 °C … +80 °C – ++
Environmental conditions
Ambient and rod temperature Seal versions
in the area of the piston rod "M" "V"
Standard –20 °C … +80 °C 1) ++ + 2)
Components
AL 25 … 32 mm
4 6 1 6 3 5 6 6 2
Components
AL 40 … 200 mm
3 5 1 5 2 4 5
Seal kits 1)
ØAL = piston Ø
ØMM = piston rod Ø
Priming / painting
Priming | By default, hydraulic cylinders are primed with Painting | By default, hydraulic cylinders can be ordered
a coating (color gentian blue RAL 5010) of min. 40 μm. in the CP4 to CP7 corrosivity category in the RAL colors.
Other colors on request. Following surfaces of cylinders and attachment parts are
Following surfaces of cylinders and attachment parts are not painted:
not primed: ▶ All fit diameters and connection surfaces to the
▶ All fit diameters to the customer side customer side
▶ Sealing surfaces for line connection ▶ Sealing surfaces for line connection
▶ Sealing surfaces for flange connection ▶ Sealing surfaces for flange connection
▶ Spherical− / plain bearing ▶ Spherical− / plain bearing
▶ Grease nipples ▶ Grease nipples
Notice:
Surfaces not primed or painted are protected with
solvent-free corrosion protection agent. Accessories ordered
as a separate order item are not primed or painted by default.
Corresponding priming and/or painting on request.
Corrosivity categories
Corrosivity categories
Applications
Class Requirements
Inside Outside
240 h salt spray test SST Field of application, e.g. Not suitable for outdoor
(DIN EN ISO 9227) Hall atmosphere, exposure.
Priming CP3 240 h condensation water test KKT Air humidity ≤ 60%,
(DIN EN ISO 6270-2) no thermal load.
Layer thickness: min. 40 μm
480 h salt spray test SST. Unheated buildings in which Urban and industrial
(DIN EN ISO 9227) there may be condensation atmosphere with little salt or
CP4 480 h condensation water test KKT (production rooms, storage sulfur dioxide load.
(DIN EN ISO 6270-2) and sport halls).
Nominal layer thickness: 120 μm
720 h salt spray test SST. Silo and debris facilities, Industrial and coastal areas
(DIN EN ISO 9227) chemical plants, boathouses with medium salt load.
CP5 480 h condensation water test KKT above sea water, laundries,
(DIN EN ISO 6270-2) breweries with high humidity
Nominal layer thickness: 140 μm and medium contamination.
Painting
1000 h salt spray test SST. Buildings or areas with almost Industrial areas with large
(DIN EN ISO 9227) permanent condensation and humidity and aggressive
CP6 480 h condensation water test KKT serious contamination. atmosphere.
(DIN EN ISO 6270-2)
Nominal layer thickness: 220 μm
1440 h salt spray test SST. Buildings or areas with almost Coastal and offshore areas
(DIN EN ISO 9227) permanent condensation and with high salt load.
CP7 480 h condensation water test KKT serious contamination.
(DIN EN ISO 6270-2)
Nominal layer thickness: 320 μm
Notice:
This list does not claim to be complete. In case of questions
regarding the compatibility with the medium or exceedance of
the boundary or application conditions, please contact us.
The ICS (Interactive Catalog System) is a selection and After having been guided through the product selection,
project planning aid for hydraulic cylinders. the user quickly and reliably gets the exact technical data
The ICS allows designers for machines and systems to of the selected component as well as 3D CAD data in the
quickly and reliably find the perfect hydraulic cylinder correct file format for all common CAD systems.
solution through logic-guided type key enquiries. This allows users to reduce costs while increasing their
This software helps to solve design and project planning competitiveness.
tasks more quickly and efficiently.
Online: www.boschrexroth.com/mill-type-cylinder
Notes
Bosch Rexroth AG © All rights reserved to Bosch Rexroth AG, also regarding any disposal,
Industrial Hydraulics exploitation, reproduction, editing, distribution, as well as in the event of
Zum Eisengießer 1 applications for industrial property rights.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements
Phone +49 (0) 93 52 / 40 30 20 concerning a certain condition or suitability for a certain application can be
my.support@boschrexroth.de derived from our information. The information given does not release the
www.boschrexroth.de user from the obligation of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.