You are on page 1of 1

DITEX TECHNOLOGIES - Loc. Mandella - 37019 Peschiera del Garda VR - ITALY info@ditex.it 26/02/2014-12.

11

OK WORKSHOP ALCOA DIESEL


46 2008 CUSTOMER #ID 02.14.0760
0 JUL EMAIL a.alcoadiesel@gmail.com
ORDER #ID

#0445110012 TURAN INJ 1 INJ 2 INJ 3 INJ 4

EQUIPMENT #1 CRI 1000 NEW STYLE V


PIEZO REFILL
EQUIPMENT #2 0 µW
EQUIPMENT #3 DX73615 DINAMIC CAPACITANCE µF
ADAPTOR 0 Bottom L µH
DELIVERY PIPE DX74251+DX74265 Top L µH
BACKLEAKAGE PIPE DX73261 A
COIL LIFT
CURRENT PROFILE 0 µm
INJ TYPE SOLENOID V
PIEZO LIFT
µm
TEST PLAN NOT SUITABLE FOR CODING PURPOSES RESISTANCE Ω
INSULATION MΩ

RAIL PRESSURE CRI 1000 NEW STYLE Q_TARGET ±∆ BL_MAX


_________ _________ _________ _________
NOTES
#
cm3/1000 cm3/1000 cm3/1000
BAR OPENING TIME pos/µsec Q BL Q BL Q BL Q BL
strokes strokes strokes

A 1350 pos 6 3 minutes

B 1400 OFF 30 Leak test

1 1350 800 µsec 50,9 4,0 46


ISO 4113 40°C ± 2°C
2 800 500 µsec 18,8 2,5
3 250 675 µsec 4,7 1,6
4 800 160 µsec 1,5 1,2
5

26/02/2014-12.11 DITEX TECHNOLOGIES reserves the right to change, modify and/or withdraw the information in this TEST DATA at any time without notice. Therefore it is recommended to order latest test plan from
http://codec.ditex.it whenever is needed.