Test Bench settings:

Shout Counter: 400

Abbreviations:

Time= T
Bench revolutions= RPM
Power Signal= PWS
Return Counterpressure = CDR
Temperature= Tmp
Intermittent atomization= Int.
Continous atomization= Cont.
Delivery= M
Injector exhaust= Rt
Single injector exhaust= Rs

-------- : Bosch considers a different order number as interchangeable


Bosch Inline Piezo Injector delivery plan
VERSION 03/09
Shout Counter: 400

Injector Manufacturer Condensors Open Start Condensors flushing Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code flushing and load RPM : 200 - 250 and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
0 445 115 003 T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
0 445 115 004 High Press.: 500 High Press.: 500 bar
Nr.Injector: from 1 PWS=3 PWS=3 PWS=4
---------------- bar
to 6 Nr. Injector :7 Nr. Injector: 7 Nr. Injector: 7
0 445 115 023
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
0 445 115 024
---------------- CDR= from 0,5 to 1 CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
0 445 115 034 CDR= 4 +/- 0,2 Bar Bar T=4 RPM=5
0 445 115 035 059 130 277 AB T=4 RPM=1 Tmp= 20-45 °C N° Injector :7
4 iniectors test 1 single injector test 1 single injector test
---------------- N° Injector :7
0 445 115 036 ----------------- PWS= Start from 1
0 445 115 037 059 130 277 AH PWS= Start from 1 20 sec. each switch,
-----------------
057 130 277 AH 20 sec. each switch, and rest 2 min. in
0 445 115 051 and rest 2 min. in pos.nr.5
Int. Cont.
0 445 115 052 pos.nr.5 M Rt M Rs M Rs
-----------------
0 445 115 082 Tmp: 20-45°C Tmp: 20-55°C
0 445 115 083
80 - 90 140 - 150 4,4 - 5,4 10,5 4,4 - 4,8 3,4 7,8 - 8,2 2,6
---------- ----------- ---------- ---------- ------------ ---------- ------------ -----------
80 - 90 140 - 150 4,2 - 5 10,4 3,8 - 4,4 3 8,2 - 8,6 2,6

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
7,8 - 8,2 8,6 10,2 - 10,6 9,8 10 - 10,2 2,8 8,4 - 8,8 2,8 9,4 - 9,8 9 7,4 - 7,6 8,8 7,6 - 8 2,6
-------------- --------- ------------ ---------- ------------- ---------- -------------- ---------- -------------- ---------- -------------- ------------ ------------ ------------
8,4 - 9 9 10,5 - 11 10 10,3 - 10,6 2,8 8,6 - 9 2,6 9,4 - 9,6 8,4 7,2 - 7,8 8,8 7,6 - 8,2 2,6

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09

Shout Counter: 400

Injector Manufacturer Condensors Open start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code flushing and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 High Press.: 500 bar
N°Injector: from 1 PWS=3 PWS=3 PWS=4
bar
to 6 N° Injector :7 N° Injector: 7 N° Injector: 7
0 445 115 018 PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
0 445 115 019 CDR= da 0,5 a 1 Bar CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
----------------- CDR= 4 +/- 0,2 Bar Tmp= 20-45 °C T=4 RPM=5
0 445 115 038 T=4 RPM=1 N° Injector :7
4 injectors test 1 single injector test 1 single injector test
0 445 115 039 N° Injector :7
----------------- PWS= Start from 1
0 445 115 053 PWS= Start from 1 20 sec. each switch,
0 445 115 054 20 sec. each switch, Int. Cont. and rest 2 min. in M Rt M Rs M Rs
and rest 2 min. in pos.nr.5
059 130 277 AC pos.nr.5 80 - 90 140 - 150 Tmp: 20-55°C 4 - 5,2 10,8 3,6 - 4,4 3,2 7,6 - 8,2 2,8
----------------- Tmp: 20-45°C ---------- ----------- ---------- ---------- ------------ ---------- ------------ -----------
059 130 277 AJ 80 - 90 140 - 150 4 4,8 10,4 3,6 3,8 3 7,4 7,8 2,6
057 130 277 AJ

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
7,4 7,8 8,8 9,8 - 10 10 9,4 9,8 3 7,6 - 8 2,6 8,6 - 9,2 9,4 6 6,8 9 6,8 7,2 2,6
-------------- --------- ------------ ---------- ------------- ---------- -------------- ---------- -------------- ---------- -------------- ------------ ------------ ------------
7,8 - 8 8,8 10 10,2 10 9,4 - 9,6 2,8 7,8 - 8 2,8 8,6 - 9 9,4 6,8 - 7,2 9 6,8 - 7 2,6

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09

Shout Counter: 400

Injector Manufacturer Condensors flushing Open start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 bar High Press.: 500 bar
N°Injector: from 1 PWS=3 PWS=3 PWS=4
to 6 N° Injector :7 N° Injector: 7 N° Injector: 7
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
CDR= 4 +/- 0,2 Bar CDR= da 0,5 a 1 Bar CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
T=4 RPM=1 Tmp= 20-45 °C T=4 RPM=5
0 445 115 057 N° Injector :7 N° Injector :7
4 injectors test 1 single injector test 1 single injector test
0 445 115 058
PWS= Start from 1 20 PWS= Start from 1
sec. each switch, and 20 sec. each switch,
rest 2 min. in pos.nr.5 Int. Cont. and rest 2 min. in M Rt M Rs M Rs
pos.nr.5
Tmp: 20-45°C
057 130 277 AG 90 - 100 140 - 150 Tmp: 20-55°C 2,8 3,6 10 3,4 3,6 3 7 - 7,4 2,4

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
7,6 7,8 8,4 9,4 9,6 9,6 9 9,2 2,8 7,4 7,6 2,6 8 - 8,2 9 6,2 6,6 8,6 6,6 7 2,6

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09
Shout Counter: 400

Injector Manufacturer Condensors flushing Open start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 bar High Press.: 500 bar
N°Injector: from 1 to PWS=3 PWS=3 PWS=4
6 N° Injector :7 N° Injector: 7 N° Injector: 7
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
CDR= 4 +/- 0,2 Bar CDR= da 0,5 a 1 Bar CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
T=4 RPM=1 Tmp= 20-45 °C T=4 RPM=5
4 injectors test 1 single injector test 1 single injector test
N° Injector :7 N° Injector :7
0 445 115 007 PWS= Start from 1 20 PWS= Partire da 1 per
sec. each switch, and 20 sec. Ogni scatto, e
rest 2 min. in pos.nr.5 Int. Cont. sostare per 2 min. in
pos.n°5
Tmp: 20-45°C M Rt M Rs M Rs
Tmp: 20-55°C
82 00 340 068
82 00 409 398 130 - 140 140 - 150 3,2 4 11,4 3,2 3,6 3,2 5,8- 6,6 2,8
82 00 505 056
82 00 804 536

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test Prova con 1 iniettore 4 injectors test 4 injectors test 1 single injector test
per volta
M Rt M Rt M Rs M Rs M Rt M Rt M Rs
6,8 7,2 8,6 7,8 8,6 9,6 7 7,8 3 6,4 7,2 2,8 7 7,6 8,6 5 5,6 8 3,8 5,2 2,6

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09

Shout Counter: 400

Injector Manufacturer Condensors flushing Open Start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 bar High Press.: 500 bar
Nr.Injector: from 1 to PWS=3 PWS=3 PWS=4
6 N° Injector :7 N° Injector: 7 N° Injector: 7
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
0 445 115 008 XX XX 7 792 721
CDR= 4 +/- 0,2 Bar CDR= from 0,5 to 1 CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
0 445 115 048 XX XX 7 785 685 T=4 RPM=1 Bar T=4 RPM=5
0 445 115 070 13 53 7 801 940 N° Injector :7 Tmp= 20-45 °C N° Injector :7
4 injectors test 1 single injector test 1 single injector test
13 53 7 805 685
13 53 7 807 208 PWS= Start from 1 20 PWS= Partire da 1 per
13 53 7 807 207 sec. each switch, and 20 sec. Ogni scatto, e
13 53 7 809 193 rest 2 min. in pos.nr.5 Int. Cont. sostare per 2 min. in M Rt M Rs M Rs
pos.n°5
Tmp: 20-45°C 3,1 4,2 10,3 3,2 4,2 2,7 6,9 7,2 2,3
140 - 150 150 - 160 Tmp: 20-55°C

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
7,2 7,5 8,3 8,9 9,3 9,5 8,9 9,1 2,6 7,4 8 2,5 7,4 7,9 8,9 6,4 6,9 8,7 6,4 6,9 2,4

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09

Shout Counter: 400

Injector Manufacturer Condensors flushing Open Start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 bar High Press.: 500 bar
Nr.Injector: from 1 to PWS=3 PWS=3 PWS=4
6 N° Injector :7 N° Injector: 7 N° Injector: 7
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
CDR= 4 +/- 0,2 Bar CDR= from 0,5 to 1 CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
T=4 RPM=1 Bar T=4 RPM=5
0 445 116 004 N° Injector :7 Tmp= 20-45 °C N° Injector :7
4 injectors test 1 single injector test 1 single injector test
0 445 116 005
0 445 116 029 PWS= Start from 1 20 PWS= Partire da 1 per
0 445 116 030 sec. each switch, and 20 sec. Ogni scatto, e
rest 2 min. in pos.nr.5 Int. Cont. sostare per 2 min. in
pos.n°5 M Rt M Rs M Rs
Tmp: 20-45°C
03L 130 277 Tmp: 20-55°C 2,8 4,8 10 3,6 4,2 2,7 7 7,4 2,3
120 130 130 -140

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
7 7,2 9,2 7,8 9,6 9,2 8,8 9,2 2,5 7,6 7,8 2,4 7,8 8,4 9 6 6,6 8,2 6,6 7,2 2,4

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09

Shout Counter: 400

Injector Manufacturer Condensors flushing Open Start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 bar High Press.: 500 bar
Nr.Injector: from 1 to PWS=3 PWS=3 PWS=4
6 N° Injector :7 N° Injector: 7 N° Injector: 7
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
CDR= 4 +/- 0,2 Bar CDR= from 0,5 to 1 CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
T=4 RPM=1 Bar T=4 RPM=5
N° Injector :7 Tmp= 20-45 °C N° Injector :7
4 injectors test 1 single injector test 1 single injector test
XX XX 7 797 877
0 445 116 001 13 53 7 797 878 PWS= Start from 1 20 PWS= Partire da 1 per
13 53 7 809 190 sec. each switch, and 20 sec. Ogni scatto, e
rest 2 min. in pos.nr.5 Int. Cont. sostare per 2 min. in
pos.n°5 M Rt M Rs M Rs
Tmp: 20-45°C
Tmp: 20-55°C 3,4 3,6 10 3 3,6 2,6 6,6 7 2,3
140 150 150 -160

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
6,8 7 8,4 8,4 8,8 9 8,4 8,6 2,6 7 7,4 2,4 7 7,2 8,8 6,6 6,8 8,4 6,2 6,6 2,3

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.
Bosch Inline Piezo Injector Delivery Plan
VERSION 03/09

Shout Counter: 400

Injector Manufacturer Condensors flushing Open Start Condensators Press.:250±20 Bar Press.:250±20 Bar Press.:800±20 Bar
Number code and load RPM : 200 - 250 flushing and load RPM : 1000 RPM : 1000 RPM : 2000
RPM 500 RPM 2000
T=4 ; RPM=1 T=4 ; RPM=6 T=4 ; RPM=6 T=3 ; RPM=6
High Press.: 500 bar High Press.: 500 bar
Nr.Injector: from 1 to PWS=3 PWS=3 PWS=4
6 N° Injector :7 N° Injector: 7 N° Injector: 7
PWS=2 CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
CDR= 4 +/- 0,2 Bar CDR= from 0,5 to 1 CDR= 4 +/- 0,2 Bar Tmp= 20-55 °C Tmp= 20-55 °C Tmp= 30-70 °C
T=4 RPM=1 Bar T=4 RPM=5
N° Injector :7 Tmp= 20-45 °C N° Injector :7
4 injectors test 1 single injector test 1 single injector test

0 445 116 014 059 130 277 AR PWS= Start from 1 20 PWS= Partire da 1 per
0 445 116 015 sec. each switch, and 20 sec. Ogni scatto, e
rest 2 min. in pos.nr.5 Int. Cont. sostare per 2 min. in
pos.n°5 M Rt M Rs M Rs
Tmp: 20-45°C
Tmp: 20-55°C 3 3,4 9,9 3,3 - 3,5 2,7 8,1 8,4 2,3
140 150 150 -160

Press.:800±20 Bar Press.:1000±20 Bar Press.:1000±20 Bar Press.:1200±20 Bar Press.:1200±20 Bar Press.:1600±20 Bar Press.:1600±20 Bar
RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000 RPM : 2000

T=3 ; RPM=6 T=3 ; RPM=6 T=3 ; RPM=6 T=2 ; RPM=6 T=2 ; RPM=6 T=1 ; RPM=6 T=1 ; RPM=6
PWS=4 PWS=4 PWS=4 PWS=4 PWS=4 PWS=5 PWS=5
N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7 N° Injector: 7
CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar CDR= 4 +/- 0,2 Bar
Tmp= 30-70 °C Tmp= 40-80 °C Tmp= 40-80 °C Tmp= 45-85 °C Tmp= 45-85 °C Tmp= 50-90 °C Tmp= 50-90 °C

4 injectors test 4 injectors test 1 single injector test 1 single injector test 4 injectors test 4 injectors test 1 single injector test

M Rt M Rt M Rs M Rs M Rt M Rt M Rs
6,8 7 8,4 8,8 8,5 10,7 10,9 9,6 10,3 10,5 2,6 8,6 9,1 2,4 9 9,2 8,5 7,1 7,5 8,1 7,3 7,6

NOTE: If delivery does not match parameters given, implement or decrease pressure by 20 Bar so as to catch up with tolerance s.