You are on page 1of 1

.

.
.
.
If any one of.the above warnings is encountered, please check the data. Most
.
of the cases are related to excessive calculated deflection, which exceeds the
allowable y ..This causes COM624 to terminate the calculations. The problem
t
occurs when.the pile is too flexible, soils are too soft, or load is too large.
.
 Pile too flexible – If the I and E of the pile section are too small,
COM624 stops.
 Soils are too soft or loose – If Phi or K is too small for sandy soils and C
or e50 is too small for cohesive soils, COM624 stops.
 Load is too large – If P, M, or yt is too large, COM624 stops.
 Large surface slope angle or batter angle – If the surface or batter angle is
larger than the soil friction angle, COM624 stops.
 Large H – If the distance between pile top and ground surface is too
large, COM624 stops.

HINT: view the COM624 OUTPUT report to get the error message.

51