Professional Documents
Culture Documents
Ucrete TC TDS MBS Version 2
Ucrete TC TDS MBS Version 2
DESCRIPTION For best results, the site and material temperatures should
Ucrete TC is a heavy duty encapsulation resin available in be in the range 15–25°C. Minimum substrate temperature
matt or gloss. 8°C.
Ucrete TC is designed as an integral part of the Ucrete DP Do not apply when atmospheric condensation is occurring
and Ucrete TZ flooring systems. or likely to occur before full cure is attained, i.e., when the
dew point is reached or when the ambient or substrate
When used as part of a Ucrete system, it exhibits temperature is within 3°C of the dew point.
exceptional chemical and temperature resistance.
Mix with an electric drill and paddle and apply by foam
When used as part of the Ucrete DP systems it can be squeegee and back roll. Avoid ponding.
extended up onto the Ucrete RG cove providing a seamless
finish from skirting to skirting. It is important to achieve the specified coverage rates if the
required slip resistance is to be achieved
Ucrete TC is not a floor coating.
GROUTING OF UCRETE TZ AND TZAS
FEATURES AND BENEFITS Use Ucrete TC, mix with a drill and paddle adding extra filler
Expert installation by fully trained licensed applicators as required to achieve the desired consistency.
Non-solvented and non-tainting from the end of mixing,
The mixed grout is hand trowelled over the whole surface,
as tested by the Campden BRI
ensuring that it is pushed into and fills the pits and voids.
Gloss and matt versions of Ucrete TC are available
Does not support bacterial growth or mould After spreading, immediately remove as much excess grout
as possible with the trowel edge or a hard
PERFORMANCE DATA scraper/squeegee.
NON TAINTING Normally, full cure is reached after 24 hours, but under cold,
Ucrete TC is non-solvented and non tainting from the end dry conditions this may be extended to 48 hours.
of mixing, as tested by the Campden BRI.
CLEANING AGENT
APPLICATION TO UCRETE DP Tools may be cleaned immediately after use using Xylene.
One coat is adequate for most situations, but two or more
coats can be applied if a smoother, but less slip resistant,
surface is required.
Page 1 of 3
Date of Issue: July 2021
Version No. 2
Ucrete TC
Heavy duty chemical resistant encapsulation resin
Page 2 of 3
Date of Issue: July 2021
Version No. 2
Ucrete TC
Heavy duty chemical resistant encapsulation resin
Resin Products Products are sold subject to the Company's standard conditions of sale and all
Can cause irritation, dermatitis or allergic reaction. Use protective equipment customers, users and specifiers, should ensure that they examine the
particularly for skin and eyes. Use only in well ventilated areas. Company's latest Product Literature.
Page 3 of 3
Date of Issue: July 2021
Version No. 2